-- ZyXEL Communications Corporation
-- Private Enterprise MIB definition

-- This file describes the ZyXEL Communications Corporation Enterprise MIB.
-- It contains ZyXEL products OIDs, and common managed objects.

-- $Log: zyxel-MGS3712D.mib $
-- Revision 1.13  2011/01/20 09:18:57  Irene
-- Support Errdisable on SNMP trap group.
-- Revision 1.12  2011/01/06 08:40:14  Irene
-- Change macSetup OID to 135
-- Revision 1.11  2010/12/20 10:07:58  Irene
-- 1. Fix transceiver DDM info entry description
-- 2. support mac flush
-- Revision 1.10  2010/12/17 06:33:21  Shinge
-- add ac prefer feature
-- Revision 1.9  2010/10/07 08:34:09  Irene
-- modify vlanCounter MIB object order, move vlanCounterPort to last for backward compatible
-- Revision 1.8  2010/08/11 01:51:24  Shinge
-- RSTP operEdge support
-- Revision 1.7  2010/07/23 09:05:12  Shinge
-- fix compiling errors when using SilverCreek for guest vlan
-- Revision 1.6  2010/07/23 06:28:28  Irene
-- Bug fixed:
-- 1) fix compiling errors when using SilverCreek
-- 2) The access type of the errdisableTrapPort, errdisableTrapReason and
--     errdisableTrapMode are not-accessible but they can be accessed.
-- Revision 1.5  2010/07/14 08:28:52  Shinge
-- bug fix : add guest vlan host mode SYNTAX type
-- Revision 1.4  2010/07/01 09:08:48  Irene
-- Bug fixed, fix compiling errors when using SNMPc
-- Revision 1.3  2010/06/30 08:05:15  Irene
-- 1) Support PPPoe-IA
-- 2) Support CPU Protection
-- 3) Revise Errdisable Recovery
-- 4) Support Smart isolation and Private VLAN
-- Revision 1.2  2010/06/30 03:25:40  Shinge
-- merge guest vlan
-- Revision 1.1  2010/06/30 03:18:39  Irene
-- Initial revision

ZYXEL-MGS370012C-MIB DEFINITIONS ::= BEGIN

    IMPORTS
    enterprises        FROM RFC1155-SMI

    OBJECT-TYPE, Integer32, Counter32, Unsigned32, Counter64
        FROM SNMPv2-SMI              -- RFC2578
    RowStatus, DateAndTime, TruthValue, StorageType, MacAddress ,TDomain, TAddress
        FROM SNMPv2-TC               -- RFC2579
    DisplayString
          FROM RFC1213-MIB
    EnabledStatus
        FROM  P-BRIDGE-MIB
    PortList
        FROM  Q-BRIDGE-MIB
    dot1dBasePort
            FROM BRIDGE-MIB
    InterfaceIndexOrZero             -- RFC2863
        FROM IF-MIB
    SnmpAdminString
        FROM SNMP-FRAMEWORK-MIB      -- RFC2571
    InetAddressType, InetAddress
        FROM INET-ADDRESS-MIB        -- RFC2851
    OperationResponseStatus
        FROM DISMAN-PING-MIB
    dot1agCfmMdIndex
        FROM IEEE8021-CFM-MIB
    dot1agCfmMaIndex
        FROM IEEE8021-CFM-MIB
    dot1agCfmMepIdentifier
        FROM IEEE8021-CFM-MIB
    IpAddress
        FROM SNMPv2-SMI
   ifIndex
     FROM IF-MIB
     -- from [RFC2863]

    NOTIFICATION-TYPE
        FROM SNMPv2-SMI
    sysObjectID
        FROM RFC1213-MIB
    Counter, TimeTicks
        FROM RFC1155-SMI
    BridgeId, Timeout
        FROM BRIDGE-MIB;

    zyxel             OBJECT IDENTIFIER ::= { enterprises 890 }
    products          OBJECT IDENTIFIER ::= { zyxel 1 }
    accessSwitch      OBJECT IDENTIFIER ::= { products 5 }
    esSeries          OBJECT IDENTIFIER ::= { accessSwitch 8 }
    mgs370012c        OBJECT IDENTIFIER ::= { esSeries 75 }


--  sysInfo
    sysInfo         OBJECT IDENTIFIER ::= { mgs370012c 1 }

        sysSwPlatformMajorVers OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                      "SW platform major version, e.g. 3."
        ::= { sysInfo 1 }

        sysSwPlatformMinorVers OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                      "SW platform minor version, e.g. 50."
        ::= { sysInfo 2 }

        sysSwModelString OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                      "Model letters, e.g. TJ"
        ::= { sysInfo 3 }

        sysSwVersionControlNbr OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                      "Version control number, e.g. 0."
        ::= { sysInfo 4 }

        sysSwDay OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                      "SW compilation day, e.g. 19."
        ::= { sysInfo 5 }

        sysSwMonth OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                      "SW compilation month, e.g. 8."
        ::= { sysInfo 6 }

        sysSwYear OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                      "SW compilation year, e.g. 2004."
        ::= { sysInfo 7 }

        sysHwMajorVers OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                      "HW major version number, e.g. 1."
        ::= { sysInfo 8 }

        sysHwMinorVers OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                      "HW minor version number, e.g. 0."
        ::= { sysInfo 9 }

        sysSerialNumber OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                      "Serial number"
        ::= { sysInfo 10 }

        sysSwBootUpImage OBJECT-TYPE
        SYNTAX  INTEGER{
                 image-1(1),
                 image-2(2)
        }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                      "Current system boot up image,
                      You can change the boot up image of next rebooting by setting sysMgmtBootupImage."
        ::= { sysInfo 11 }


-- rateLimitSetup
    rateLimitSetup OBJECT IDENTIFIER ::= { mgs370012c 2 }

        rateLimitState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "Ingress/egress rate limiting enabled/disabled for the switch."
        ::= { rateLimitSetup 1 }

-- rateLimitPortTable

        rateLimitPortTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF RateLimitPortEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { rateLimitSetup 2 }

    rateLimitPortEntry OBJECT-TYPE
        SYNTAX    RateLimitPortEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in rateLimitPortTable."
        INDEX              { dot1dBasePort }
        ::= { rateLimitPortTable 1 }

        RateLimitPortEntry ::=
           SEQUENCE {
            rateLimitPortState        EnabledStatus,
            rateLimitPortPeakRate     INTEGER,
            rateLimitPortEgrRate      INTEGER,
            rateLimitPortCommitRate   INTEGER,
            rateLimitPortPeakState    EnabledStatus,
            rateLimitPortEgrState     EnabledStatus,
            rateLimitPortCommitState  EnabledStatus,
            rateLimitPortPeakBurst    INTEGER,
            rateLimitPortEgrBurst     INTEGER,
            rateLimitPortCommitBurst  INTEGER
           }

        rateLimitPortState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "This item can enabled/disabled Commit Rate, Peak Rate, and Egress Rate at the same time.
                           It's meaningless while reading this entry."
        ::= { rateLimitPortEntry 1 }

        rateLimitPortPeakRate OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Peak rate in Kbit/s.  The range of FE port is between 1 and 100,000. For GE port, the range is between 1 and 1000,000."
        ::= { rateLimitPortEntry 2 }

        rateLimitPortEgrRate OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Egress rate in Kbit/s.  The range of FE port is between 1 and 100,000. For GE port, the range is between 1 and 1000,000."
        ::= { rateLimitPortEntry 3 }

        rateLimitPortCommitRate OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Commit rate in Kbit/s.  The range of FE port is between 0 and 100,000. For GE port, the range is between 0 and 1000,000."
        ::= { rateLimitPortEntry 4 }


        rateLimitPortPeakState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Ingress peak rate limiting enabled/disabled on the port."
        ::= { rateLimitPortEntry 5 }

        rateLimitPortEgrState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Egress rate limiting enabled/disabled on the port."
        ::= { rateLimitPortEntry 6 }

        rateLimitPortCommitState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Ingress commit rate limiting enabled/disabled on the port."
        ::= { rateLimitPortEntry 7 }

        rateLimitPortPeakBurst OBJECT-TYPE
        SYNTAX  INTEGER(0..128000)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Peak burst size in Kbits.  The range is between 0 and 128,000."
        ::= { rateLimitPortEntry 8 }

        rateLimitPortEgrBurst OBJECT-TYPE
        SYNTAX  INTEGER(0..128000)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Egress burst size in Kbits.  The range is between 0 and 128,000."
        ::= { rateLimitPortEntry 9 }

        rateLimitPortCommitBurst OBJECT-TYPE
        SYNTAX  INTEGER(0..128000)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Commit burst size in Kbits.  The range is between 0 and 128,000."
        ::= { rateLimitPortEntry 10 }

-- brLimitSetup
    brLimitSetup OBJECT IDENTIFIER ::= { mgs370012c 3 }

        brLimitState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Broadcast/multicast/DLF rate limiting enabled/disabled for the switch."
        ::= { brLimitSetup 1 }

-- brLimitPortTable
        brLimitPortTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF BrLimitPortEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { brLimitSetup 2 }

    brLimitPortEntry OBJECT-TYPE
        SYNTAX    BrLimitPortEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in brLimitPortTable."
        INDEX              { dot1dBasePort }
        ::= { brLimitPortTable 1 }

        BrLimitPortEntry ::=
           SEQUENCE {
            brLimitPortBrState    EnabledStatus,
            brLimitPortBrRate    INTEGER,
            brLimitPortMcState    EnabledStatus,
            brLimitPortMcRate    INTEGER,
            brLimitPortDlfState    EnabledStatus,
            brLimitPortDlfRate    INTEGER
           }

        brLimitPortBrState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Broadcast rate limiting enabled/disabled on the port."
        ::= { brLimitPortEntry 1 }

        brLimitPortBrRate OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Allowed broadcast rate in pkts/s. For FE port,
                          the maximum value is 148800. For GE port, the maximum value is 262143."
        ::= { brLimitPortEntry 2 }

        brLimitPortMcState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Multicast rate limiting enabled/disabled on the port."
        ::= { brLimitPortEntry 3 }

        brLimitPortMcRate OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "AAllowed mullticast rate in pkts/s. For FE port,
                          the maximum value is 148800. For GE port, the maximum value is 262143."
        ::= { brLimitPortEntry 4 }

        brLimitPortDlfState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Destination lookup failure frames rate limiting enabled/disabled on the port."
        ::= { brLimitPortEntry 5 }

        brLimitPortDlfRate OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Allowed destination lookup failure frames rate in pkts/s.
                          For FE port, the maximum value is 148800. For GE port, the maximum value is 262143."
        ::= { brLimitPortEntry 6 }

-- portSecuritySetup
    portSecuritySetup OBJECT IDENTIFIER ::= { mgs370012c 4 }

    portSecurityState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { portSecuritySetup 1 }

        portSecurityPortTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF PortSecurityPortEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { portSecuritySetup 2 }

    portSecurityPortEntry OBJECT-TYPE
        SYNTAX    PortSecurityPortEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in portSecurityPortTable."
        INDEX              { dot1dBasePort }
        ::= { portSecurityPortTable 1 }

        PortSecurityPortEntry ::=
           SEQUENCE {
            portSecurityPortState        EnabledStatus,
            portSecurityPortLearnState   EnabledStatus,
            portSecurityPortCount        INTEGER,
            portSecurityAlarmCount       INTEGER
           }

        portSecurityPortState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Port Security enabled/disabled on the port.
                          Active(1) means this port only accept frames from static MAC addresses that are configured for the port,
                          and dynamic MAC address frames up to the number specified by portSecurityPortCount object."
        ::= { portSecurityPortEntry 1 }

        portSecurityPortLearnState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "MAC address learning  enabled/disable on the port."
        ::= { portSecurityPortEntry 2 }

        portSecurityPortCount OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Number of (dynamic) MAC addresses that may be learned on the port."
        ::= { portSecurityPortEntry 3 }

        portSecurityAlarmCount OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Alarm threshold of (dynamic) MAC addresses on the port."
        ::= { portSecurityPortEntry 4 }

    portSecurityMacFreeze OBJECT-TYPE
        SYNTAX  PortList
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "This entry is used to execute MacFreeze action to port.
                          It's meaningless while reading this entry."
        ::= { portSecuritySetup 3 }

    portSecurityVMLTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF PortSecurityVMLEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { portSecuritySetup 4 }

    portSecurityVMLEntry OBJECT-TYPE
        SYNTAX    PortSecurityVMLEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in portSecurityVMLTable."
        INDEX              { portSecurityVMLPort, portSecurityVMLVID }
        ::= { portSecurityVMLTable 1 }

        PortSecurityVMLEntry ::=
           SEQUENCE {
            portSecurityVMLPort           INTEGER,
            portSecurityVMLVID            INTEGER,
            portSecurityVMLMacLimit       INTEGER,
            portSecurityVMLRowStatus      RowStatus,
            portSecurityVMLAlarmCount     INTEGER
           }

        portSecurityVMLPort OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "The configured port number of VLAN MAC Limit."
        ::= { portSecurityVMLEntry 1 }

        portSecurityVMLVID OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "The configured VLAN number of VLAN MAC Limit."
        ::= { portSecurityVMLEntry 2 }

        portSecurityVMLMacLimit OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "The MAC limit of specific port and VLAN."
        ::= { portSecurityVMLEntry 3 }

        portSecurityVMLRowStatus OBJECT-TYPE
        SYNTAX  RowStatus
        ACCESS  read-create
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { portSecurityVMLEntry 4 }

        portSecurityVMLAlarmCount OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "The alarm threshold of specific port and VLAN."
        ::= { portSecurityVMLEntry 5 }

-- vlanTrunkPortTable
    vlanTrunkSetup OBJECT IDENTIFIER ::= { mgs370012c 5 }

        vlanTrunkPortTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF VlanTrunkPortEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { vlanTrunkSetup 1 }

    vlanTrunkPortEntry OBJECT-TYPE
        SYNTAX    VlanTrunkPortEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in vlanTrunkPortTable."
        INDEX              { dot1dBasePort }
        ::= { vlanTrunkPortTable 1 }

        VlanTrunkPortEntry ::=
           SEQUENCE {
            vlanTrunkPortState        EnabledStatus
           }

        vlanTrunkPortState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "VlanTrunking enabled/disabled on the port.
                          Active(1) to allow frames belonging to unknown
                          VLAN groups to pass through the switch."
        ::= { vlanTrunkPortEntry 1 }

--  ctlProtTransSetup
    ctlProtTransSetup OBJECT IDENTIFIER ::= { mgs370012c 6 }

        ctlProtTransState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Bridge control protocol transparency enabled/disabled for the switch"
        ::= { ctlProtTransSetup 1 }

-- ctlProtTransTunnelPortTable

        ctlProtTransTunnelPortTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF CtlProtTransTunnelPortEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { ctlProtTransSetup 2 }

    ctlProtTransTunnelPortEntry OBJECT-TYPE
        SYNTAX    CtlProtTransTunnelPortEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in ctlProtTransTunnelPortTable."
        INDEX              { dot1dBasePort }
        ::= { ctlProtTransTunnelPortTable 1 }

        CtlProtTransTunnelPortEntry ::=
           SEQUENCE {
            ctlProtTransTunnelMode    INTEGER
           }

        ctlProtTransTunnelMode OBJECT-TYPE
        SYNTAX  INTEGER{
        peer(0),
        tunnel(1),
        discard(2),
        network(3)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Bridge control protocol transparency mode for the port.
                          Modes:  Peer(0), Tunnel(1), Discard(2),  Network(3)"
        ::= { ctlProtTransTunnelPortEntry 1 }

-- ------------------------------------------------------------------
--
--  dot1x Setup
--
--  for AAA Service
--  1. rename radius8021xSetup as dot1xSetup
--  2. remove radiusLoginPrecedence (AAA Service: authentication login)
--  3. remove radiusAnd8021xServer (AAA Service: radius server setup)
--  4. DO NOT change oid for backward compatible
--
-- ------------------------------------------------------------------
--  dot1xSetup
    dot1xSetup OBJECT IDENTIFIER ::= { mgs370012c 7 }

--  portAuthState
        portAuthState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "802.1x port authentication enabled/disabled for the switch."
        ::= { dot1xSetup 3 }


-- portAuthTable

        portAuthTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF PortAuthEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { dot1xSetup 4 }

        portAuthEntry OBJECT-TYPE
        SYNTAX    PortAuthEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in portAuthTable."
        INDEX              { dot1dBasePort }
        ::= { portAuthTable 1 }

        PortAuthEntry ::=
           SEQUENCE {
            portAuthEntryState                            EnabledStatus,
            portReAuthEntryState                          EnabledStatus,
            portReAuthEntryTimer                          INTEGER,
            portAuthQuietPeriod                           INTEGER,
            portAuthTxPeriod                              INTEGER,
            portAuthSupplicantTimeout                     INTEGER,
            portAuthMaxRequest                            INTEGER,
            portAuthGuestVlanState                        EnabledStatus,
            portAuthGuestVlan                             INTEGER,
            portAuthGuestVlanHostMode                     INTEGER,
            portAuthGuestVlanHostModeMultiSecureNumber    INTEGER
           }

        portAuthEntryState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "802.1x port authentication enabled or disabled on the port."
        ::= { portAuthEntry 1 }

        portReAuthEntryState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "802.1x port re-authentication enabled or disabled on the port."
        ::= { portAuthEntry 2 }

        portReAuthEntryTimer OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Re-authentication timer in seconds."
        ::= { portAuthEntry 3 }

    portAuthQuietPeriod OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Quiet period in seconds."
        ::= { portAuthEntry 4 }

        portAuthTxPeriod OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Tx period in seconds."
        ::= { portAuthEntry 5 }

        portAuthSupplicantTimeout OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Supplicant Timeout in seconds."
        ::= { portAuthEntry 6 }

        portAuthMaxRequest OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Max request."
        ::= { portAuthEntry 7 }

        portAuthGuestVlanState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Guest Vlan State."
        ::= { portAuthEntry 8 }

        portAuthGuestVlan OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Guest Vlan ID."
        ::= { portAuthEntry 9 }

        portAuthGuestVlanHostMode OBJECT-TYPE
            SYNTAX  INTEGER {
                multi-Host(0),
                multi-Secure(1)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Guest Vlan Host Mode."
        ::= { portAuthEntry 10 }

        portAuthGuestVlanHostModeMultiSecureNumber OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Guest Vlan Host Mode Multi-Secure number."
        ::= { portAuthEntry 11 }

-- hardwareInfo
    hwMonitorInfo OBJECT IDENTIFIER ::= { mgs370012c 8 }

-- fabRpmTable

        fanRpmTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF FanRpmEntry
        ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
                     ""
        ::= { hwMonitorInfo 1 }

    fanRpmEntry OBJECT-TYPE
        SYNTAX    FanRpmEntry
        ACCESS    not-accessible
        STATUS    current
        DESCRIPTION        "An entry in fanRpmTable."
        INDEX              { fanRpmIndex }
        ::= { fanRpmTable 1 }

        FanRpmEntry ::=
           SEQUENCE {
            fanRpmIndex       INTEGER,
            fanRpmCurValue    INTEGER,
            fanRpmMaxValue    INTEGER,
            fanRpmMinValue    INTEGER,
            fanRpmLowThresh   INTEGER,
            fanRpmDescr       DisplayString
           }

        fanRpmIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "Index of FAN."
        ::= { fanRpmEntry 1 }

        fanRpmCurValue OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "Current speed in Revolutions Per Minute (RPM) on the fan."
        ::= { fanRpmEntry 2 }

        fanRpmMaxValue OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "Maximum speed measured in Revolutions Per Minute (RPM) on the fan."
        ::= { fanRpmEntry 3 }

        fanRpmMinValue OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "Minimum speed measured in Revolutions Per Minute (RPM) on the fan."
        ::= { fanRpmEntry 4 }

        fanRpmLowThresh OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "The minimum speed at which a normal fan should work."
        ::= { fanRpmEntry 5 }

        fanRpmDescr OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "'Normal' indicates that this fan is functioning above the minimum speed.
                          'Error' indicates that this fan is functioning below the minimum speed."
        ::= { fanRpmEntry 6 }

-- tempTable

        tempTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF TempEntry
        ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
                     ""
        ::= { hwMonitorInfo 2 }

    tempEntry OBJECT-TYPE
        SYNTAX    TempEntry
        ACCESS    not-accessible
        STATUS    current
        DESCRIPTION        "An entry in tempTable."
        INDEX              { tempIndex }
        ::= { tempTable 1 }

        TempEntry ::=
           SEQUENCE {
            tempIndex       INTEGER,
            tempCurValue    INTEGER,
            tempMaxValue    INTEGER,
            tempMinValue    INTEGER,
            tempHighThresh  INTEGER,
            tempDescr       DisplayString
           }

        tempIndex OBJECT-TYPE
        SYNTAX  INTEGER {
            mac (1),
            cpu (2),
            phy (3)
        }
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "Index of temperature unit. 1:MAC, 2:CPU, 3:PHY"
        ::= { tempEntry 1 }

        tempCurValue OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "The current temperature measured at this sensor."
        ::= { tempEntry 2 }

        tempMaxValue OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "The maximum temperature measured at this sensor."
        ::= { tempEntry 3 }

        tempMinValue OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "The minimum temperature measured at this sensor."
        ::= { tempEntry 4 }

        tempHighThresh OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "The upper temperature limit at this sensor."
        ::= { tempEntry 5 }

        tempDescr OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "'Normal' indicates temperatures below the threshold and 'Error' for those above."
        ::= { tempEntry 6 }

-- voltageTable

        voltageTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF VoltageEntry
        ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
                     ""
        ::= { hwMonitorInfo 3 }

    voltageEntry OBJECT-TYPE
        SYNTAX    VoltageEntry
        ACCESS    not-accessible
        STATUS    current
        DESCRIPTION        "An entry in voltageTable."
        INDEX              { voltageIndex }
        ::= { voltageTable 1 }

        VoltageEntry ::=
           SEQUENCE {
            voltageIndex           INTEGER,
            voltageCurValue        INTEGER,
            voltageMaxValue        INTEGER,
            voltageMinValue        INTEGER,
            voltageNominalValue    INTEGER,
            voltageLowThresh       INTEGER,
            voltageDescr           DisplayString
           }

        voltageIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "Index of voltage."
        ::= { voltageEntry 1 }

        voltageCurValue OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "The current voltage reading."
        ::= { voltageEntry 2 }

        voltageMaxValue OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "The maximum voltage measured at this point."
        ::= { voltageEntry 3 }

        voltageMinValue OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "The minimum voltage measured at this point."
        ::= { voltageEntry 4 }

        voltageNominalValue OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "The normal voltage at wchich the switch work."
        ::= { voltageEntry 5 }

        voltageLowThresh OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "The minimum voltage at which the switch should work."
        ::= { voltageEntry 6 }

        voltageDescr OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "'Normal' indicates that the voltage is within an acceptable operating range
                          at this point; otherwise 'Error' is displayed."
        ::= { voltageEntry 7 }
-- PowerSourceStatus
 powerSourceStatus OBJECT IDENTIFIER  ::= { hwMonitorInfo 4 }

        powerSourceMode OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "The current power source reading."
        ::= { powerSourceStatus 1 }

    powerSourceTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF PowerSourceEntry
        ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
                     ""
        ::= { powerSourceStatus 2 }


    powerSourceEntry OBJECT-TYPE
        SYNTAX    PowerSourceEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in powerSourceTable."
        INDEX              { index }
        ::= { powerSourceTable 1 }

        PowerSourceEntry ::=
           SEQUENCE {
            index        INTEGER,
            powerType    DisplayString,
            powerStatus  DisplayString
           }

        index OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "Index of power source."
        ::= { powerSourceEntry 1 }

        powerType OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "The current power source reading."
        ::= { powerSourceEntry 2 }
         powerStatus OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "The current power source reading."
        ::= { powerSourceEntry 3 }


        -- snmpSetup
    snmpSetup OBJECT IDENTIFIER ::= { mgs370012c 9 }

        snmpGetCommunity OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { snmpSetup 1 }

        snmpSetCommunity OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { snmpSetup 2 }

        snmpTrapCommunity OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { snmpSetup 3 }

--  snmpTrapDestTable
        snmpTrapDestTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF SnmpTrapDestEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { snmpSetup 4 }

    snmpTrapDestEntry OBJECT-TYPE
        SYNTAX    SnmpTrapDestEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in snmpTrapDestTable."
        INDEX              { snmpTrapDestIP }
        ::= { snmpTrapDestTable 1 }

        SnmpTrapDestEntry ::=
           SEQUENCE {
            snmpTrapDestIP          IpAddress,
            snmpTrapDestRowStatus   RowStatus,
            snmpTrapDestPort        INTEGER,
            snmpTrapVersion         INTEGER,
            snmpTrapUserName        DisplayString
           }

        snmpTrapDestIP OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "IP address of trap destination."
        ::= { snmpTrapDestEntry 1 }

        snmpTrapDestRowStatus OBJECT-TYPE
        SYNTAX  RowStatus
        ACCESS  read-create
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { snmpTrapDestEntry 2 }

        snmpTrapDestPort OBJECT-TYPE
        SYNTAX INTEGER
        MAX-ACCESS read-write
        STATUS  mandatory
        DESCRIPTION
                          "The UDP port of the trap destination."
        ::= { snmpTrapDestEntry 3 }

        snmpTrapVersion OBJECT-TYPE
        SYNTAX  INTEGER {
            v1(0),
            v2c(1),
            v3(2)
        }
        MAX-ACCESS read-write
        STATUS  mandatory
        DESCRIPTION
                          "The SNMP protocol version to send traps."
        ::= { snmpTrapDestEntry 4 }

        snmpTrapUserName OBJECT-TYPE
        SYNTAX DisplayString
        MAX-ACCESS read-write
        STATUS  mandatory
        DESCRIPTION
                          "The user name for sending SNMPv3 traps."
        ::= { snmpTrapDestEntry 5 }

--snmpVersion
        snmpVersion OBJECT-TYPE
        SYNTAX     INTEGER {
            v2c(0),
            v3(1),
            v3v2c(2)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
        "The SNMP version to be used. v3v2c means that the manager
        can get/set by SNMPv3 and can get by SNMPv2c."
        ::= { snmpSetup 5 }

-- snmpUserTable

    snmpUserTable OBJECT-TYPE
        SYNTAX SEQUENCE OF SnmpUserEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
                "A table that contains SNMPv3 user information."
        ::= { snmpSetup 6 }

        snmpUserEntry OBJECT-TYPE
        SYNTAX SnmpUserEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
            "An entry of snmpUserTable."
        INDEX { snmpUserName }
        ::= { snmpUserTable 1 }

       SnmpUserEntry ::=
            SEQUENCE {
                snmpUserName            DisplayString,
                snmpUserSecurityLevel   INTEGER,
                snmpUserAuthProtocol    INTEGER,
                snmpUserPrivProtocol    INTEGER
            }

    snmpUserName OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
        "The user name."
    ::= { snmpUserEntry 1 }

    snmpUserSecurityLevel OBJECT-TYPE
    SYNTAX  INTEGER {
            noAuthNoPriv(0),
            authNoPriv(1),
            authPriv(2)
        }
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
        "The level of security at which SNMP messages can be sent or
        with which operations are being processed."
    ::= { snmpUserEntry 2 }

    snmpUserAuthProtocol OBJECT-TYPE
    SYNTAX  INTEGER {
            md5(0),
            sha(1)
        }
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
        "The type of authentication protocol to be used."
    ::= { snmpUserEntry 3 }

    snmpUserPrivProtocol OBJECT-TYPE
    SYNTAX     INTEGER {
            des(0),
            aes(1)
        }
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
        "The type of privacy protocol to be used."
    ::= { snmpUserEntry 4 }


--  snmpTrapGroupTable
        snmpTrapGroupTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF SnmpTrapGroupEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { snmpSetup 7 }
    snmpTrapGroupEntry OBJECT-TYPE
        SYNTAX    SnmpTrapGroupEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in snmpTrapGroupTable."
        INDEX              { snmpTrapDestIP }
        ::= { snmpTrapGroupTable 1 }

        SnmpTrapGroupEntry ::=
           SEQUENCE {
            snmpTrapSystemGroup        BITS,
            snmpTrapInterfaceGroup     BITS,
            snmpTrapAAAGroup           BITS,
            snmpTrapIPGroup            BITS,
            snmpTrapSwitchGroup        BITS
           }

        snmpTrapSystemGroup OBJECT-TYPE
        SYNTAX    BITS {
          coldStart(0),
          warmStart(1),
          fanSpeed(2),
          temperature(3),
          voltage(4),
          reset (5),
          timeSync (6),
          intrusionlock(7),
          loopGuard(13),
          errdisable(14),
          externalalarm(10),
          dyinggasp(15),
          acprefer(16)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { snmpTrapGroupEntry 1 }

        snmpTrapInterfaceGroup OBJECT-TYPE
        SYNTAX    BITS {
          linkup(0),
          linkdown(1),
          autonegotiation(2),
          lldp(3),
          transceiver-ddm(4),
          macoverthreshold(6)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { snmpTrapGroupEntry 2 }

        snmpTrapAAAGroup OBJECT-TYPE
                   SYNTAX    BITS {
        authentication(0),
        accounting(1)
    }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { snmpTrapGroupEntry 3 }

        snmpTrapIPGroup OBJECT-TYPE
                   SYNTAX    BITS {
        ping(0),
        traceroute(1)
    }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { snmpTrapGroupEntry 4 }

        snmpTrapSwitchGroup OBJECT-TYPE
                   SYNTAX    BITS {
        stp(0),
        mactable(1),
        rmon(2),
        cfm(3)
    }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { snmpTrapGroupEntry 5 }



--  dateTimeSetup
    dateTimeSetup         OBJECT IDENTIFIER ::= { mgs370012c 10 }

        dateTimeServerType OBJECT-TYPE
        SYNTAX  INTEGER {
          none(1),
                daytime(2),
                time(3),
                ntp(4)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      "The time service protocol."
        ::= { dateTimeSetup 1 }

        dateTimeServerIP OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      "IP address of time server."
        ::= { dateTimeSetup 2 }

        dateTimeZone OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      "The time difference between UTC. Ex: +01"
        ::= { dateTimeSetup 3 }

        dateTimeNewDateYear OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      "The new date in year."
        ::= { dateTimeSetup 4 }

        dateTimeNewDateMonth OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      "The new date in month."
        ::= { dateTimeSetup 5 }

        dateTimeNewDateDay OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      "The new date in day."
        ::= { dateTimeSetup 6 }

        dateTimeNewTimeHour OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      "The new time in hour."
        ::= { dateTimeSetup 7 }

        dateTimeNewTimeMinute OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      "The new time in minute."
        ::= { dateTimeSetup 8 }

        dateTimeNewTimeSecond OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      "The new time in second."
        ::= { dateTimeSetup 9 }
-- dateTimeDaylightSavingTimeSetup OBJECT-TYPE
    dateTimeDaylightSavingTimeSetup         OBJECT IDENTIFIER ::= { dateTimeSetup 10 }

        daylightSavingTimeState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      "Daylight saving time service enabled/disabled for the switch."
        ::= { dateTimeDaylightSavingTimeSetup 1 }

        daylightSavingTimeStartDateWeek OBJECT-TYPE
        SYNTAX  INTEGER {
                 first(1),
                 second(2),
                 third(3),
                 fourth(4),
                 last(5)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      "Daylight saving time service start week."
        ::= { dateTimeDaylightSavingTimeSetup 2 }

        daylightSavingTimeStartDateDay OBJECT-TYPE
        SYNTAX  INTEGER {
                 sunday(0),
                 monday(1),
                 tuesday(2),
                 wednesday(3),
                 thursday(4),
                 friday(5),
                 saturday(6)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      "Daylight saving time service start day."
        ::= { dateTimeDaylightSavingTimeSetup 3 }

        daylightSavingTimeStartDateMonth OBJECT-TYPE
        SYNTAX  INTEGER {
                 january(1),
                 february(2),
                 march(3),
                 april(4),
                 may(5),
                 june(6),
                 july(7),
                 august(8),
                 september(9),
                 october(10),
                 november(11),
                 december(12)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      "Daylight saving time service start month."
        ::= { dateTimeDaylightSavingTimeSetup 4 }

        daylightSavingTimeStartDateHour OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      "Daylight saving time service start time."
        ::= { dateTimeDaylightSavingTimeSetup 5 }

        daylightSavingTimeEndDateWeek OBJECT-TYPE
        SYNTAX  INTEGER {
                 first(1),
                 second(2),
                 third(3),
                 fourth(4),
                 last(5)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      "Daylight saving time service end week."
        ::= { dateTimeDaylightSavingTimeSetup 6 }

        daylightSavingTimeEndDateDay OBJECT-TYPE
        SYNTAX  INTEGER {
                 sunday(0),
                 monday(1),
                 tuesday(2),
                 wednesday(3),
                 thursday(4),
                 friday(5),
                 saturday(6)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      "Daylight saving time service end day."
        ::= { dateTimeDaylightSavingTimeSetup 7 }

        daylightSavingTimeEndDateMonth OBJECT-TYPE
        SYNTAX  INTEGER {
                 january(1),
                 february(2),
                 march(3),
                 april(4),
                 may(5),
                 june(6),
                 july(7),
                 august(8),
                 september(9),
                 october(10),
                 november(11),
                 december(12)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      "Daylight saving time service end month."
        ::= { dateTimeDaylightSavingTimeSetup 8 }

        daylightSavingTimeEndDateHour OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      "Daylight saving time service end time."
        ::= { dateTimeDaylightSavingTimeSetup 9 }

        dateTimeSyncInterval OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      "The time sync interval in minute. The range is between 1 to 3600 minute(s)"
        ::= { dateTimeSetup 11 }

--  sysMgmt
    sysMgmt         OBJECT IDENTIFIER ::= { mgs370012c 11 }

        sysMgmtConfigSave OBJECT-TYPE
        SYNTAX  INTEGER {
                 config-1(1),
                 config-2(2)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      "If setting value is given, the variable write index will be set and running-config will be written to the assigned configuration file.
                      If not, running-config will be written to the booting one."
        ::= { sysMgmt 1 }

        sysMgmtBootupConfig OBJECT-TYPE
        SYNTAX  INTEGER {
                 config-1(1),
                 config-2(2)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      "The setting value (read index) will be written into non-volatile memory.
                      While rebooting, the variable write index is equal to read index initially.
                      You can change the value of write index by CLI / MIB."
        ::= { sysMgmt 2 }

        sysMgmtReboot OBJECT-TYPE
        SYNTAX  INTEGER {
                nothing(0),
                reboot(1)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      "Reboot switch from SNMP. 1:Reboot, 0:Nothing"
        ::= { sysMgmt 3 }

    sysMgmtDefaultConfig OBJECT-TYPE
        SYNTAX  INTEGER {
                nothing(0),
                reset-to-default(1)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      "Erase running config and reset to default."
        ::= { sysMgmt 4 }

    sysMgmtLastActionStatus OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),
                success(1),
                fail(2)
        }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                      "Display status of last mgmt action."
        ::= { sysMgmt 5 }

    sysMgmtSystemStatus OBJECT-TYPE
    SYNTAX    BITS {
        sysAlarmDetected(0),
        sysTemperatureError(1),
        sysFanRPMError(2),
        sysVoltageRangeError(3)
    }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
        "This variable indicates the status of the system.
         The sysMgmtAlarmStatus is a bit map represented
         a sum, therefore, it can represent multiple defects
         simultaneously. The sysNoDefect should be set if and only if
         no other flag is set.

         The various bit positions are:
            0   sysAlarmDetected
            1   sysTemperatureError
            2   sysFanRPMError
            3   sysVoltageRangeError"
        ::= { sysMgmt 6 }

    sysMgmtCPUUsage OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "Show device CPU load in %, it's the snapshot of CPU load when
            getting the values."
        ::= { sysMgmt 7 }

    sysMgmtBootupImage OBJECT-TYPE
        SYNTAX  INTEGER {
                 image-1(1),
                 image-2(2)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      "The setting value (read index) will be written into non-volatile memory.
                      When rebooting, the selected image will be used.
                      You can change the value of write index by CLI / MIB."
        ::= { sysMgmt 8 }

    sysMgmtCounterReset OBJECT-TYPE
        SYNTAX  INTEGER {
                 enable(1),
                 disable(2)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      "Reset all port counters."
        ::= { sysMgmt 9 }

-- Tftp service
        sysMgmtTftpServiceSetup OBJECT IDENTIFIER ::= { sysMgmt 10 }

        sysMgmtTftpServerIp OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          " IP address of TFTP server"
        ::= { sysMgmtTftpServiceSetup 1 }

        sysMgmtTftpRemoteFileName OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "The file name that you want to backup to or restore from TFTP server"
        ::= { sysMgmtTftpServiceSetup 2 }

        sysMgmtTftpConfigIndex OBJECT-TYPE
        SYNTAX  INTEGER {
                config-1(1),
                config-2(2)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Index of system configuration which you want to restore."
        ::= { sysMgmtTftpServiceSetup 3 }

        sysMgmtTftpAction OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),
                 backup-config(1),
                restore-config(2)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          " Action of tftp service. 1: Backup running-config to tftp server, 2: Restore config from tftp server."
        ::= { sysMgmtTftpServiceSetup 4 }

    sysMgmtTftpActionStatus OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),
                success(1),
                fail(2),
                under-action(3)
        }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                      "Display status of mgmt action."
        ::= { sysMgmtTftpServiceSetup 5 }

--  layer2Setup
    layer2Setup         OBJECT IDENTIFIER ::= { mgs370012c 12 }

        vlanTypeSetup OBJECT-TYPE
        SYNTAX  INTEGER {
                 dot1Q(1),
                 port-based(2)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { layer2Setup 1 }

        igmpSnoopingStateSetup OBJECT-TYPE
        SYNTAX  INTEGER {
            disable(0),
            igmpv2(1),
            igmpv3(2)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { layer2Setup 2 }

        tagVlanPortIsolationState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { layer2Setup 3 }

        stpState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { layer2Setup 4 }

        igmpFilteringStateSetup OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { layer2Setup 6 }

        unknownMulticastFrameForwarding OBJECT-TYPE
        SYNTAX  INTEGER {
             flooding(1),
             drop(2)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { layer2Setup 7 }

      multicastGrpHostTimeout OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      "Specify host timeout for all multicast groups when the specific port is in auto mode."
        ::= { layer2Setup 8 }



        reservedMulticastFrameForwarding OBJECT-TYPE
        SYNTAX  INTEGER {
             flooding(1),
             drop(2)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { layer2Setup 10 }

        igmpsnp8021pPriority OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      "Set the 802.1p priority of control messages for igmp-snooping(0~8, 8-No Change)"
        ::= { layer2Setup 11 }

        igmpsnpVlanMode OBJECT-TYPE
        SYNTAX  INTEGER {
             auto(1),
             fixed(2)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { layer2Setup 12 }

        stpMode OBJECT-TYPE
        SYNTAX  INTEGER {
             rstp(1),
             mrstp(2),
             mstp (3)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { layer2Setup 13 }


--  igmpsnpVlanTable
        igmpsnpVlanTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF IgmpsnpVlanEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { layer2Setup 14 }

    igmpsnpVlanEntry OBJECT-TYPE
        SYNTAX    IgmpsnpVlanEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in IgmpsnpVlanTable."
        INDEX              { igmpsnpVid }
        ::= { igmpsnpVlanTable 1 }

        IgmpsnpVlanEntry ::=
           SEQUENCE {
            igmpsnpVid              INTEGER,
            igmpsnpVlanName         DisplayString,
            igmpsnpVlanRowStatus    RowStatus
           }


        igmpsnpVid OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { igmpsnpVlanEntry 1 }


     igmpsnpVlanName OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { igmpsnpVlanEntry 2 }


        igmpsnpVlanRowStatus OBJECT-TYPE
        SYNTAX  RowStatus
        ACCESS  read-create
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= {  igmpsnpVlanEntry 3 }

        igmpsnpQuerierMode OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { layer2Setup 15 }

                  ethernetCfmStateSetup OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { layer2Setup 16 }

         igmpSnpReportProxySetup OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      "IGMP Snooping report-proxy mode"
        ::= { layer2Setup 17 }

         lldpStateSetup OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { layer2Setup 18 }

        smartIsolationState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { layer2Setup 19 }

--  igmpsnpUnknownMcastVlanTable
        igmpsnpUnknownMcastVlanTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF IgmpsnpUnknownMcastVlanEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { layer2Setup 20 }

    igmpsnpUnknownMcastVlanEntry OBJECT-TYPE
        SYNTAX    IgmpsnpUnknownMcastVlanEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in IgmpsnpUnknownMcastVlanTable."
        INDEX              { igmpsnpVid }
        ::= { igmpsnpUnknownMcastVlanTable 1 }

        IgmpsnpUnknownMcastVlanEntry ::=
           SEQUENCE {
              igmpsnpVid                    INTEGER,
              igmpsnpVlanName               DisplayString,
              igmpsnpUnknownFramFlooding    INTEGER,
              igmpsnpVlanRowStatus          RowStatus
           }


        igmpsnpVid OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { igmpsnpUnknownMcastVlanEntry 1 }


     igmpsnpVlanName OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { igmpsnpUnknownMcastVlanEntry 2 }



     igmpsnpUnknownFramFlooding OBJECT-TYPE
        SYNTAX  INTEGER {
             drop(1),
             flooding(2)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= {  igmpsnpUnknownMcastVlanEntry 3 }

        igmpsnpVlanRowStatus OBJECT-TYPE
        SYNTAX  RowStatus
        ACCESS  read-create
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= {  igmpsnpUnknownMcastVlanEntry 4 }

--  ipSetup
    ipSetup         OBJECT IDENTIFIER ::= { mgs370012c 13 }

        dnsIpAddress OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { ipSetup 1 }

        defaultMgmt OBJECT-TYPE
        SYNTAX  INTEGER {
            in-band(0),
            out-of-band(1)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { ipSetup 2 }

    inbandIpSetup         OBJECT IDENTIFIER ::= { ipSetup 3 }

        inbandIpType OBJECT-TYPE
        SYNTAX  INTEGER {
            dhcp-client(0),
            static-ip(1)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { inbandIpSetup 1 }

        inbandVid OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { inbandIpSetup 2 }

        inbandStaticIp OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { inbandIpSetup 3 }

        inbandStaticSubnetMask OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { inbandIpSetup 4 }

        inbandStaticGateway OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { inbandIpSetup 5 }

    outOfBandIpSetup         OBJECT IDENTIFIER ::= { ipSetup 4 }

        outOfBandIp OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { outOfBandIpSetup 1 }

        outOfBandSubnetMask OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { outOfBandIpSetup 2 }

        outOfBandGateway OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { outOfBandIpSetup 3 }

        maxNumOfInbandIp OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { ipSetup 5 }

--  inbandIpTable
        inbandIpTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF InbandIpEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { ipSetup 6 }

    inbandIpEntry OBJECT-TYPE
        SYNTAX    InbandIpEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in inbandIpTable."
        INDEX              { inbandEntryIp, inbandEntryVid }
        ::= { inbandIpTable 1 }

        InbandIpEntry ::=
    SEQUENCE {
            inbandEntryIp            IpAddress,
            inbandEntrySubnetMask    IpAddress,
            inbandEntryGateway       IpAddress,
            inbandEntryVid           INTEGER,
            inbandEntryRowStatus     RowStatus
        }

        inbandEntryIp OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { inbandIpEntry 1 }

        inbandEntrySubnetMask OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { inbandIpEntry 2 }

        inbandEntryGateway OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { inbandIpEntry 3 }

        inbandEntryVid OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { inbandIpEntry 4 }

        inbandEntryRowStatus OBJECT-TYPE
        SYNTAX  RowStatus
        ACCESS  read-create
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { inbandIpEntry 6 }

--  filterSetup
    filterSetup         OBJECT IDENTIFIER ::= { mgs370012c 14 }

--  filterTable
           filterTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF FilterEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { filterSetup 1 }

    filterEntry OBJECT-TYPE
        SYNTAX    FilterEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in filterTable."
        INDEX              { filterMacAddr, filterVid }
        ::= { filterTable 1 }

        FilterEntry ::=
           SEQUENCE {
            filterName           DisplayString,
            filterActionState    INTEGER,
            filterMacAddr        MacAddress,
            filterVid            INTEGER,
            filterRowStatus      RowStatus
           }

        filterName OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { filterEntry 1 }

        filterActionState OBJECT-TYPE
        SYNTAX  INTEGER {
        discard-source(1),
        discard-destination(2),
        both(3)
    }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { filterEntry 2 }

        filterMacAddr OBJECT-TYPE
        SYNTAX  MacAddress
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { filterEntry 3 }

       filterVid OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { filterEntry 4 }

       filterRowStatus OBJECT-TYPE
        SYNTAX  RowStatus
        ACCESS  read-create
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { filterEntry 5 }

--  mirrorSetup
    mirrorSetup         OBJECT IDENTIFIER ::= { mgs370012c 15 }

--  mirrorState
        mirrorState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { mirrorSetup 1 }

        mirrorMonitorPort OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { mirrorSetup 2 }

-- mirrorTable

        mirrorTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF MirrorEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { mirrorSetup 3 }

    mirrorEntry OBJECT-TYPE
        SYNTAX    MirrorEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in mirrorTable."
        INDEX              { dot1dBasePort }
        ::= { mirrorTable 1 }

        MirrorEntry ::=
           SEQUENCE {
            mirrorMirroredState    EnabledStatus,
            mirrorDirection        INTEGER
           }

        mirrorMirroredState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { mirrorEntry 1 }

        mirrorDirection OBJECT-TYPE
        SYNTAX  INTEGER {
            ingress(0),
            egress(1),
            both(2)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { mirrorEntry 2 }


-- aggrSetup
    aggrSetup         OBJECT IDENTIFIER ::= { mgs370012c 16 }

        aggrState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { aggrSetup 1 }

        aggrSystemPriority OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { aggrSetup 2 }

-- aggrGroupTable

        aggrGroupTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF AggrGroupEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { aggrSetup 3 }

    aggrGroupEntry OBJECT-TYPE
        SYNTAX    AggrGroupEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in aggrGroupTable."
        INDEX              { aggrGroupIndex }
        ::= { aggrGroupTable 1 }

        AggrGroupEntry ::=
           SEQUENCE {
            aggrGroupIndex           INTEGER,
            aggrGroupState           EnabledStatus,
            aggrGroupDynamicState    EnabledStatus,
            aggrGroupCriteria        INTEGER
           }

        aggrGroupIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { aggrGroupEntry 1 }

        aggrGroupState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { aggrGroupEntry 2 }

        aggrGroupDynamicState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { aggrGroupEntry 3 }

        aggrGroupCriteria OBJECT-TYPE
        SYNTAX  INTEGER  {
        src-mac (1),
        dst-mac (2),
        src-dst-mac (3),
        src-ip  (4),
        dst-ip  (5),
        src-dst-ip (6)
        }

        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { aggrGroupEntry 4 }

-- aggrPortTable

        aggrPortTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF AggrPortEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { aggrSetup 4 }

    aggrPortEntry OBJECT-TYPE
        SYNTAX    AggrPortEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in aggrPortTable."
        INDEX              { dot1dBasePort }
        ::= { aggrPortTable 1 }

        AggrPortEntry ::=
           SEQUENCE {
            aggrPortGroup                  INTEGER,
            aggrPortDynamicStateTimeout    INTEGER,
            aggrPortActivity               INTEGER
           }

        aggrPortGroup OBJECT-TYPE
        SYNTAX  INTEGER {
            none(0),
            t1(1),
            t2(2),
            t3(3),
            t4(4),
            t5(5),
            t6(6)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { aggrPortEntry 1 }

        aggrPortDynamicStateTimeout OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                        "Set Interface LACP Timeout, 1(short) or 30(long)"
        ::= { aggrPortEntry 2 }

        aggrPortActivity OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                         "Dump Interface LACP Activity, 1(Active) or 0(Passive)"
        ::= { aggrPortEntry 3 }


-- accessCtlSetup
    accessCtlSetup         OBJECT IDENTIFIER ::= { mgs370012c 17 }

-- accessCtlTable

        accessCtlTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF AccessCtlEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { accessCtlSetup 1 }

    accessCtlEntry OBJECT-TYPE
        SYNTAX    AccessCtlEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in accessCtlTable."
        INDEX              { accessCtlService }
        ::= { accessCtlTable 1 }

        AccessCtlEntry ::=
           SEQUENCE {
            accessCtlService        INTEGER,
            accessCtlEnable         EnabledStatus,
            accessCtlServicePort    INTEGER,
            accessCtlTimeout        INTEGER
           }

        accessCtlService OBJECT-TYPE
        SYNTAX  INTEGER {
            telnet(1),
            ssh(2),
            ftp(3),
            http(4),
            https(5),
            icmp(6),
            snmp(7),
            console(8)
        }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { accessCtlEntry 1 }

        accessCtlEnable OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { accessCtlEntry 2 }

        accessCtlServicePort OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { accessCtlEntry 3 }

        accessCtlTimeout OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { accessCtlEntry 4 }

--  securedClientTable
        securedClientTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF SecuredClientEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { accessCtlSetup 2 }

    securedClientEntry OBJECT-TYPE
        SYNTAX    SecuredClientEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in securedClientTable."
        INDEX              { securedClientIndex }
        ::= { securedClientTable 1 }

        SecuredClientEntry ::=
           SEQUENCE {
            securedClientIndex     INTEGER,
            securedClientEnable    EnabledStatus,
            securedClientStartIp   IpAddress,
            securedClientEndIp     IpAddress,
            securedClientService   BITS
           }

        securedClientIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { securedClientEntry 1 }

        securedClientEnable OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { securedClientEntry 2 }

        securedClientStartIp OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { securedClientEntry 3 }

        securedClientEndIp OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { securedClientEntry 4 }

        securedClientService OBJECT-TYPE
        SYNTAX    BITS {
            telnet(0),
            ftp(1),
            http(2),
            icmp(3),
            snmp(4),
            ssh(5),
            https(6)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { securedClientEntry 5 }

--  queuingMethodSetup
    queuingMethodSetup         OBJECT IDENTIFIER ::= { mgs370012c 18 }

-- portQueuingMethodTable
        portQueuingMethodTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF PortQueuingMethodEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { queuingMethodSetup 1 }

    portQueuingMethodEntry OBJECT-TYPE
        SYNTAX    PortQueuingMethodEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in portQueuingMethodTable."
        INDEX              { dot1dBasePort, portQueuingMethodQueue }
        ::= { portQueuingMethodTable 1 }

        PortQueuingMethodEntry ::=
           SEQUENCE {
            portQueuingMethodQueue     INTEGER,
            portQueuingMethodWeight    INTEGER,
            portQueuingMethodMode      INTEGER
           }

        portQueuingMethodQueue OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "0...7"
        ::= { portQueuingMethodEntry 1 }

        portQueuingMethodWeight OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                         "0...15"
        ::= { portQueuingMethodEntry 2 }

        portQueuingMethodMode OBJECT-TYPE
        SYNTAX  INTEGER {
            strictly-priority(0),
            weighted-round-robin(1),
                weighted-fair-scheduling(2)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { portQueuingMethodEntry 3 }


-- portQueuingMethodHybridSpqTable
    portQueuingMethodHybridSpqTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF PortQueuingMethodHybridSpqEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { queuingMethodSetup 2 }

    portQueuingMethodHybridSpqEntry OBJECT-TYPE
        SYNTAX    PortQueuingMethodHybridSpqEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION
                "An entry in portQueuingMethodHybridSpqTable."
        INDEX    { dot1dBasePort }
        ::= {portQueuingMethodHybridSpqTable 1}

        PortQueuingMethodHybridSpqEntry ::=
            SEQUENCE {
                portQueuingMethodHybridSpq    INTEGER
            }

    portQueuingMethodHybridSpq OBJECT-TYPE
        SYNTAX  INTEGER {
            none(0),
            q0(1),
            q1(2),
            q2(3),
            q3(4),
            q4(5),
            q5(6),
            q6(7),
            q7(8)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Specify the queues of SPQ while other queueing method working. The selected Qx and higher serve as SPQ, and the rest of others serve as configured queuing methods."
        ::= { portQueuingMethodHybridSpqEntry 1 }



--  dhcpSetup
    dhcpSetup         OBJECT IDENTIFIER ::= { mgs370012c 19 }

        globalDhcpRelay OBJECT IDENTIFIER ::= { dhcpSetup 1 }

        globalDhcpRelayEnable OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { globalDhcpRelay 1 }

        globalDhcpRelayOption82Enable OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { globalDhcpRelay 2 }

        globalDhcpRelayInfoEnable OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { globalDhcpRelay 3 }

        globalDhcpRelayInfoData OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { globalDhcpRelay 4 }

--  globalDhcpRelayRemoteServer

        maxNumberOfGlobalDhcpRelayRemoteServer OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { globalDhcpRelay 5 }

-- globalDhcpRelayRemoteServerTable
        globalDhcpRelayRemoteServerTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF GlobalDhcpRelayRemoteServerEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { globalDhcpRelay 6 }

    globalDhcpRelayRemoteServerEntry OBJECT-TYPE
        SYNTAX    GlobalDhcpRelayRemoteServerEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in globalDhcpRelayRemoteServerTable."
        INDEX              { globalDhcpRelayRemoteServerIp }
        ::= { globalDhcpRelayRemoteServerTable 1 }

        GlobalDhcpRelayRemoteServerEntry ::=
           SEQUENCE {
            globalDhcpRelayRemoteServerIp           IpAddress,
            globalDhcpRelayRemoteServerRowStatus    RowStatus
           }

        globalDhcpRelayRemoteServerIp OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { globalDhcpRelayRemoteServerEntry 1 }

        globalDhcpRelayRemoteServerRowStatus OBJECT-TYPE
        SYNTAX  RowStatus
        ACCESS  read-create
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { globalDhcpRelayRemoteServerEntry 2 }

--
    dhcpRelay OBJECT IDENTIFIER ::= { dhcpSetup 3 }

   dhcpRelayInfoData OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { dhcpRelay 1 }

     maxNumberOfDhcpRelay OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "The maximum number of DHCP relay entries that can be created.
                          A value of 0 for this object implies that there exists settings for
                          global DHCP relay."
        ::= { dhcpRelay 2 }

     maxNumberOfDhcpRelayRemoteServer OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { dhcpRelay 3 }


     -- dhcpRelayRemoteServerTable
        dhcpRelayRemoteServerTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF DhcpRelayRemoteServerEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { dhcpRelay 4 }

    dhcpRelayRemoteServerEntry OBJECT-TYPE
        SYNTAX    DhcpRelayRemoteServerEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in dhcpRelayRemoteServerTable."
        INDEX              {  dhcpRelayVid, dhcpRelayRemoteServerIp }
        ::= { dhcpRelayRemoteServerTable 1 }

        DhcpRelayRemoteServerEntry ::=
           SEQUENCE {
            dhcpRelayVid                      INTEGER,
            dhcpRelayRemoteServerIp           IpAddress,
            dhcpRelayRemoteServerRowStatus    RowStatus
           }

        dhcpRelayVid OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { dhcpRelayRemoteServerEntry 1 }

        dhcpRelayRemoteServerIp OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { dhcpRelayRemoteServerEntry 2 }

        dhcpRelayRemoteServerRowStatus OBJECT-TYPE
        SYNTAX  RowStatus
        ACCESS  read-create
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { dhcpRelayRemoteServerEntry 3 }


-- dhcpRelayTable

        dhcpRelayTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF DhcpRelayEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { dhcpRelay 5 }


    dhcpRelayEntry OBJECT-TYPE
        SYNTAX    DhcpRelayEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in dhcpRelayTable."
        INDEX              { dhcpRelayVid }
        ::= { dhcpRelayTable 1 }

        DhcpRelayEntry ::=
           SEQUENCE {
            dhcpRelayOption82Enable   EnabledStatus,
            dhcpRelayInfoEnable       EnabledStatus
           }

        dhcpRelayOption82Enable OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { dhcpRelayEntry 1 }

        dhcpRelayInfoEnable OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { dhcpRelayEntry 2 }


--  staticRouteSetup
    staticRouteSetup         OBJECT IDENTIFIER ::= { mgs370012c 20 }

        maxNumberOfStaticRoutes OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { staticRouteSetup 1 }

-- staticRouteTable
        staticRouteTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF StaticRouteEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { staticRouteSetup 2 }

    staticRouteEntry OBJECT-TYPE
        SYNTAX    StaticRouteEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in staticRouteTable."
        INDEX              { staticRouteIp, staticRouteMask }
        ::= { staticRouteTable 1 }

        StaticRouteEntry ::=
           SEQUENCE {
            staticRouteName        DisplayString,
            staticRouteIp          IpAddress,
            staticRouteMask        IpAddress,
            staticRouteGateway     IpAddress,
            staticRouteMetric      INTEGER,
            staticRouteRowStatus   RowStatus
           }

        staticRouteName OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { staticRouteEntry 1 }

        staticRouteIp OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { staticRouteEntry 2 }

        staticRouteMask OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { staticRouteEntry 3 }

        staticRouteGateway OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { staticRouteEntry 4 }

        staticRouteMetric OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { staticRouteEntry 5 }

        staticRouteRowStatus OBJECT-TYPE
        SYNTAX  RowStatus
        ACCESS  read-create
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { staticRouteEntry 6 }

--  arpInfo
    arpInfo         OBJECT IDENTIFIER ::= { mgs370012c 21 }

--  arpTable
          arpTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF ArpEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { arpInfo 1 }

        arpEntry OBJECT-TYPE
        SYNTAX    ArpEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in arpTable."
        INDEX              { arpIpAddr, arpMacVid }
        ::= { arpTable 1 }

        ArpEntry ::=
           SEQUENCE {
            arpIndex     INTEGER,
            arpIpAddr    IpAddress,
            arpMacAddr   MacAddress,
            arpMacVid    INTEGER,
            arpType      INTEGER
           }

        arpIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpEntry 1 }

        arpIpAddr OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpEntry 2 }

        arpMacAddr OBJECT-TYPE
        SYNTAX  MacAddress
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpEntry 3 }

        arpMacVid OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpEntry 4 }

        arpType OBJECT-TYPE
        SYNTAX  INTEGER {
            static(1),
            dynamic(2)
        }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "1-static, 2-dynamic"
        ::= { arpEntry 5 }

-- portOpModeSetup
    portOpModeSetup         OBJECT IDENTIFIER ::= { mgs370012c 22 }

-- portOpModePortTable

        portOpModePortTable  OBJECT-TYPE
        SYNTAX    SEQUENCE OF PortOpModePortEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { portOpModeSetup 1 }

    portOpModePortEntry  OBJECT-TYPE
        SYNTAX    PortOpModePortEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in portOpModePortTable."
        INDEX              { dot1dBasePort }
        ::= { portOpModePortTable 1 }

        PortOpModePortEntry ::=
           SEQUENCE {
            portOpModePortSpeedDuplex      INTEGER,
            portOpModePortFlowCntl         INTEGER,
            portOpModePortName             OCTET STRING,
            portOpModePortModuleType       INTEGER,
            portOpModePortLinkUpType       INTEGER,
            portOpModePortIntrusionLock    EnabledStatus,
            portOpModePortLBTestStatus     INTEGER,
            portOpModePortCounterReset     INTEGER
           }

        portOpModePortSpeedDuplex OBJECT-TYPE
        SYNTAX  INTEGER {
            auto(0),
            speed-10-half(1),
            speed-10-full(2),
            speed-100-half(3),
            speed-100-full(4),
            speed-1000-full(5)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { portOpModePortEntry 1 }

        portOpModePortFlowCntl OBJECT-TYPE
        SYNTAX  INTEGER {
            off(0),
            on(1)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { portOpModePortEntry 2 }

        portOpModePortName  OBJECT-TYPE
        SYNTAX  OCTET STRING (SIZE(0..64))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { portOpModePortEntry 3 }

        portOpModePortModuleType  OBJECT-TYPE
        SYNTAX  INTEGER {
            fast-ethernet-10-100(0),
            gigabit-ethernet-100-1000(1)
        }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { portOpModePortEntry 4 }

        portOpModePortLinkUpType  OBJECT-TYPE
        SYNTAX  INTEGER {
            down(0),
            copper(1),
            fiber(2)
        }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { portOpModePortEntry 5 }

    portOpModePortIntrusionLock OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { portOpModePortEntry 6 }

   portOpModePortLBTestStatus OBJECT-TYPE
        SYNTAX  INTEGER {
            none(0),
            under-testing(1),
            success(2),
            fail(3)
        }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
               "This entry display latest loopback test status of port while performing loopback test."
        ::= { portOpModePortEntry 7 }

    portOpModePortCounterReset OBJECT-TYPE
        SYNTAX  INTEGER {
            enable(1),
            disable(2)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
               "This entry resets port counter."
        ::= { portOpModePortEntry 8 }

-- portBasedVlanSetup
    portBasedVlanSetup         OBJECT IDENTIFIER ::= { mgs370012c 23 }

-- portBasedVlanPortListTable

        portBasedVlanPortListTable  OBJECT-TYPE
        SYNTAX    SEQUENCE OF PortBasedVlanPortListEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { portBasedVlanSetup 1 }

    portBasedVlanPortListEntry  OBJECT-TYPE
        SYNTAX    PortBasedVlanPortListEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in portBasedVlanPortListTable."
        INDEX              { dot1dBasePort }
        ::= { portBasedVlanPortListTable 1 }

        PortBasedVlanPortListEntry ::=
           SEQUENCE {
            portBasedVlanPortListMembers    OCTET STRING
           }

        portBasedVlanPortListMembers OBJECT-TYPE
        SYNTAX  PortList
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { portBasedVlanPortListEntry 1 }
--fault MIB
faultMIB MODULE-IDENTITY
    LAST-UPDATED "200411031200Z" -- YYYY/MM/DD, HH/MM
    ORGANIZATION "ZyXEL"
    CONTACT-INFO ""
    DESCRIPTION
            "Fault event table definitions"
    ::= { mgs370012c 24 }


-- **************************************************************************
-- Local Textual Conventions
-- **************************************************************************

UtcTimeStamp ::= TEXTUAL-CONVENTION
    STATUS current
    DESCRIPTION
           "Universal Time Coordinated as a 32-bit value that designates
            the number of seconds since Jan 1, 1970 12:00AM."
    SYNTAX  Unsigned32

EventIdNumber ::= TEXTUAL-CONVENTION
   STATUS current
   DESCRIPTION
          "This textual convention describes the index that uniquely
           identifies a fault event type in the entire system. Every fault
           event type, e.g. link down, has a unique EventIdNumber."
   SYNTAX  Integer32

EventSeverity ::= TEXTUAL-CONVENTION
   STATUS current
   DESCRIPTION
          "This textual convention describes the severity of a fault event.
           The decreasing order of severity is shown in the textual
           convention."
   SYNTAX  INTEGER{
             critical (1),
             major (2),
             minor (3),
             informational (4)
           }

EventServiceAffective ::= TEXTUAL-CONVENTION
   STATUS current
   DESCRIPTION
          "This textual convention indicates whether an event is immediately
           service affecting or not."
   SYNTAX  INTEGER{
            noServiceAffected (1),
         serviceAffected (2)
           }


InstanceType ::= TEXTUAL-CONVENTION
    STATUS current
    DESCRIPTION
           "This textual convention describes the type of an instanceId
            associated with each event and by that means specifies how
            the instanceId variable should be intepreted.

            Various instanceId types are specified below to enable fault
            monitoring for different kind of devices from fixed
            configuration pizza boxes to multi chassis nodes. All
            instanceId types may not need to be used in every device
            type.

            Note also that instanceId semantics are element type dependent
            (e.g. different kind of interface naming conventions may be used)
            and thus instanceId usage may vary from element to element.

    =========================================================================
    Type            Description                                 Example form
                                                                of InstanceId
    =========================================================================
    unknown    (1)  unknown type                               - Irrelevant-
    -------------------------------------------------------------------------
    node       (2)  Associated with events originating from          1
                    the node. Used for general events that     (Node number)
                    can not be associated with any specific
                    block. InstanceId value 1 is used for
                    single node equipment.
    -------------------------------------------------------------------------
    shelf      (3)  Associated with events originating from          1
                    the shelf. In the case of fixed           (shelf number)
                    configuration devices this type is used
                    for events that are associated with the
                    physical enclosure, e.g. faults related
                    to fan etc. InstanceId value 1 is used
                    for single self equipment.
    -------------------------------------------------------------------------
    line       (4)  Associated with events originating from
                    physical interfaces or associated
                    components such as line cards.
                    InstanceId usage examples for faults
                    originating from:
                    - Physical port: Simply port number, e.g. .......1
    -------------------------------------------------------------------------
    switch     (5)  Associated with events originating from          1
                    from a switch chip or a switch card.      (switch number)
                    For single switch equipment InstanceId
                    value 1 is used, for multi swich nodes
                    InstanceId semantics if for further
                    study.
    -------------------------------------------------------------------------
    lsp        (6)  Associated with events originating from          1
                    a particular lsp.                           (lsp index)
                    NOTE: In this case the InstanceName
                    contains the lsp name and InstanceId
                    contains lsp index.
    -------------------------------------------------------------------------
    l2Interface(7)  Associated with events originating from        - TBD -
                    a particular layer 2 interface. Used for
                    layer 2 related events such as L2 control
                    protocol faults. InstanceId semantics is
                    for further study.
    -------------------------------------------------------------------------
    l3Interface(8)  Associated with events originating from        - TBD -
                    a particular layer 3 interface. Used for
                    layer 3 related events such as L3 control
                    protocol faults. InstanceId semantics is
                    for further study.
    -------------------------------------------------------------------------
    rowIndex  (9)   Associated with events reporting about a
                    'logical' or conceptual table that consists
                    of rows.  The Instance Id is the index/key
                    for a row in the table.  The format of the
                    Instance Id will simply be a series of decimal
                    numbers seperated by a '.':
    ========================================================================="

    SYNTAX  INTEGER {
              unknown (1),
              node (2),
              shelf (3),
              line (4),
              switch (5),
              lsp (6),
              l2Interface(7),
              l3Interface(8),
              rowIndex(9)
            }



MstiOrCistInstanceIndex ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
        "This textual convention is an extension of the
        MstiInstanceIndex convention.  This extension permits the
        additional value of zero, which means Common and Internal
        Spanning Tree (CIST)."
    SYNTAX      Integer32 (0..16)


-- *****************************************************************************
-- Top level structure of this MIB.
-- *****************************************************************************

eventObjects        OBJECT IDENTIFIER ::= { faultMIB  1 }


-- *****************************************************************************
-- Event Table
--
-- Event table reports all currently active fault events. Only normal type of
-- faults (i.e. faults that are not automatically and immediately cleared) are
-- present in the event table. Delta faults (i.e. faults that are automatically
-- cleared) are reported only by using trap messages.
-- *****************************************************************************

eventTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF EventEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
            "A list of currently active fault events. All faults
             of normal type regardless of their severity level
             are recorded in the event table. When a normal
             type fault is cleared it is deleted from the event
             table."
    ::= { eventObjects 1 }

eventEntry OBJECT-TYPE
    SYNTAX      EventEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
            "An entry containing information about an
             event in the event table."
    INDEX   { eventSeqNum }
    ::= { eventTable 1 }

EventEntry ::=
    SEQUENCE {
      eventSeqNum           Integer32,
      eventEventId          EventIdNumber,
      eventName             DisplayString,
      eventInstanceType     InstanceType,
      eventInstanceId       DisplayString,
      eventInstanceName     DisplayString,
      eventSeverity         EventSeverity,
      eventSetTime          UtcTimeStamp,
      eventDescription      DisplayString,
      eventServAffective    EventServiceAffective,
      eventInstanceIdNumber Integer32
   }

eventSeqNum OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "This variable represents the sequence number of an event.
             Sequence number is incremented monotonically starting
             from 0 until it reaches its maximum and wraps around back
             to 0.

             Sequence number is incremented when
             - the state of a normal type fault is set on (the same sequence
             number is present in the events table as well as in the trap
             that is sent to notify about the fault on event)
             - delta event occurs (sequence number present in trap message)
             - the state of a normal type fault is set off (sequence number
             present in trap that is sent to notify for clearing)."
    ::= { eventEntry 1 }

eventEventId OBJECT-TYPE
    SYNTAX      EventIdNumber
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "This variable represents the event ID which uniquely
             identifies the event in the entire system."
    ::= { eventEntry 2 }

eventName OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (0..40))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "This variable represents the name of the event, for
             example 'Ethernet Link Down'"
    ::= { eventEntry 3 }

eventInstanceType OBJECT-TYPE
    SYNTAX      InstanceType
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "This variable represents the type of InstanceId of a
             particular event in the event table. In brief
             the instanceType refers to the type of sub-component
             generating this event in the system, for example
             switch (5). For more details see the textual
             conventions section.

             AFFECTS:   eventInstanceId,
                        eventInstanceName"
    ::= { eventEntry 4 }

eventInstanceId OBJECT-TYPE
    SYNTAX  DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "This variable represents the InstanceId of a particular
             event in the event current table. In brief the instanceId
             refers to the sub-component generating this event in the
             system, for example '1' for port 1. For more details see
             the textual conventions section.

             DEPENDS ON:  eventInstanceType"
    ::= { eventEntry 5 }

eventInstanceName OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "This variable is mainly used to store additional information
             about the sub-component that is generating an event. For
             example this field may specify what cooling fan is faulty.

             DEPENDS ON:  eventInstanceType"
    ::= { eventEntry 6 }

eventSeverity OBJECT-TYPE
    SYNTAX      EventSeverity
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "This variable dictates the urgency of action when a event
             occurs. There are four severity levels - Critical, Major,
             Minor, and Informational.  Critical events are those, which
             require immediate operator intervention to prevent/reduce
             system down time. Major events require quick attention and
             Minor events possibly require some attention. Informational
             events indicate the occurrence of events that may need to be
             investigated."
    ::= { eventEntry 7 }

eventSetTime OBJECT-TYPE
    SYNTAX      UtcTimeStamp
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "This table contains only normal events and this variable
             represents the time when the event become active, i.e. the
             number of seconds since Jan 1, 1970 12:00AM."
    ::= { eventEntry 8 }


eventDescription OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (0..255))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "This variable contains a description of the event and reasons
             behind the event. This is a free format alpha-numeric string
             that is set by the entity generating this event. This variable
             may be empty if there is no usefull information to report.
             The maximum length of this string is 255 characters."
    ::= { eventEntry 9 }

eventServAffective OBJECT-TYPE
    SYNTAX      EventServiceAffective
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "This variable indicates whether the event is service affective or not"
    ::= { eventEntry 10 }

eventInstanceIdNumber OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "This variable represents the InstanceId of a particular
             event in the event current table. In brief the instanceId
             refers to the sub-component generating this event in the
             system, for example '1' for port 1. For more details see
             the textual conventions section.

             DEPENDS ON:  eventInstanceType"
    ::= { eventEntry 11 }


-- fault Trap MIB
faultTrapsMIB MODULE-IDENTITY
    LAST-UPDATED "200411011200Z" -- YYYY/MM/DD, HH/MM
    ORGANIZATION "ZyXEL"
    CONTACT-INFO ""
    DESCRIPTION
            "Fault event trap definitions"
    ::= { mgs370012c 25 }

trapInfoObjects             OBJECT IDENTIFIER ::= { faultTrapsMIB 1}
trapNotifications           OBJECT IDENTIFIER ::= { faultTrapsMIB 2}


-- **************************************************************************
-- Local Textual Conventions
-- **************************************************************************

EventPersistence ::= TEXTUAL-CONVENTION
   STATUS current
   DESCRIPTION
          "This textual convention indicates whether the event is delta
           (automatically and immediately cleared) or normal (not
           automatically cleared)."
   SYNTAX  INTEGER{
            normal (1),
         delta (2)
           }


-- **************************************************************************
-- Trap information object definitions
-- **************************************************************************

trapRefSeqNum OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Indicates the former sequence number of a cleared event
             in the event table. Not intended to read but only used in
             trap notifications."
    ::= { trapInfoObjects 1 }

trapPersistence OBJECT-TYPE
    SYNTAX      EventPersistence
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Indicates whether the event is delta (automatically and
             immediately cleared) or normal (not automatically cleared).
             Not intended to read but only used in trap notifications."
    ::= { trapInfoObjects 2 }

trapSenderNodeId OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Represents the node ID of the sending network element. If not
             supported should be set to 0. Not intended to read but only
             used in trap notifications."
    ::= { trapInfoObjects 3 }

trapSenderStatus OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Represents the trap status. 0 means cleared, 1 means happened."
    ::= { trapInfoObjects 4 }



-- ***************************************************************************
-- Trap definitions
-- ***************************************************************************

eventOnTrap NOTIFICATION-TYPE
         OBJECTS {
                  eventSeqNum,
                  eventEventId,
                  eventName,
                  eventSetTime,
                  eventSeverity,
                  eventInstanceType,
                  eventInstanceId,
                  eventInstanceName,
                  eventServAffective,
                  eventDescription,
                  eventInstanceIdNumber,
                  trapPersistence,
                  trapSenderNodeId,
                  trapSenderStatus,
                  sysObjectID}
         STATUS current
         DESCRIPTION
           "This trap is used to inform network management system that a delta
           fault event (events that are automatically cleared) has occured
           or a normal fault event (not automatically cleared) state has
           been set on.

           Objects are used as follows:
           - eventSeqNum is the sequence number of the event. For normal
           type of events must equal to the sequence number of the event
           in the events table.
           - eventEventId specifies what fault event has occured.
           - eventName specifies the name of the fault event.
           - eventSetTime indicates when fault event has occured
           (delta events) or when fault has been set on (normal events).
           - eventSeverity reports the severity level of the event.
           - eventInstanceType indicates what kind of object is faulty.
           - eventInstanceId specifies what instance is faulty.
           - eventInstanceName may contain textual description for
           the faulty object.
           - eventServAffective specifies whether the event is
           immediately service affcetive.
           - eventDescription reports possible additional information about the event.
           - trapPersistence tells whether this event is a delta or normal event.
           - trapSenderNodeId specifies the node ID of the sending network element if
           configuring it is supported for the network element, otherwise 0.
           - trapSenderStatus specifes the trap status.
           - sysObjectID specifies what kind of equipment reports the fault event.

           For more information see the eventTable specification"
         ::= { trapNotifications 1 }

eventClearedTrap NOTIFICATION-TYPE
         OBJECTS {
                  eventSeqNum,
                  eventEventId,
                  eventSetTime,
                  eventInstanceType,
                  eventInstanceId,
                  eventInstanceIdNumber,
                  trapRefSeqNum,
                  trapSenderNodeId,
                  trapSenderStatus,
                  sysObjectID}
         STATUS current
         DESCRIPTION
           "This trap is used to inform network management system that a normal
           type fault event has been cleared (state set off).

           Objects are used as follows:
           - eventSeqNum is the sequence number of the this clearing event. Note that
           the sequence number of the cleared event is reported in the trapRefSeqNum
           object.
           - eventEventId specifies what event has been cleared.
           - eventSetTime indicates when fault event has been cleared.
           - eventInstanceType indicates what kind of object has been
           faulty.
           - eventInstanceId specifies what instance has been faulty.
           - trapRefSeqNum specifies the sequence number of the cleared event (i.e.
           the sequence number was assigned for the event in the events table).
           - trapSenderNodeId specifies the node ID of the sending network element if
           configuring it is supported for the network element, otherwise 0.
           - sysObjectID specifies what kind of equipment reports the clearing event.

           For more information see the eventTable specification"
         ::= { trapNotifications 2 }

--  multicastPortSetup
    multicastPortSetup         OBJECT IDENTIFIER ::= { mgs370012c 26 }

        multicastPortTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF MulticastPortEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { multicastPortSetup 1 }

    multicastPortEntry OBJECT-TYPE
        SYNTAX    MulticastPortEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in multicastPortTable."
        INDEX              { dot1dBasePort }
        ::= { multicastPortTable 1 }

        MulticastPortEntry ::=
        SEQUENCE {
            multicastPortMaxGroupLimited         EnabledStatus,
            multicastPortMaxOfGroup              INTEGER,
            multicastPortIgmpFilteringProfile    DisplayString,
            multicastPortQuerierMode             INTEGER,
            multicastPortThrottlingAction        INTEGER,
            multicastPortLeaveMode               INTEGER,
            multicastPortLeaveTimeout            INTEGER,
            multicastPortFastLeaveTimeout        INTEGER,
            multicastPortUnknownMulticast        INTEGER
        }



        multicastPortMaxGroupLimited OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { multicastPortEntry 2 }

        multicastPortMaxOfGroup OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "0..255"
        ::= { multicastPortEntry 3 }

        multicastPortIgmpFilteringProfile OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { multicastPortEntry 4 }

        multicastPortQuerierMode OBJECT-TYPE
        SYNTAX  INTEGER {
               auto(1),
            fixed(2),
            edge(3)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { multicastPortEntry 5 }

        multicastPortThrottlingAction OBJECT-TYPE
        SYNTAX  INTEGER {
         deny(1),
         replace(2)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                       "Specify throttling action for each port"
        ::= { multicastPortEntry 6 }

        multicastPortLeaveMode OBJECT-TYPE
        SYNTAX  INTEGER {
               normal(0),
            immediate(1),
            fast(2)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { multicastPortEntry 7 }

        multicastPortLeaveTimeout  OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "200..6348800"
        ::= { multicastPortEntry 8 }

        multicastPortFastLeaveTimeout  OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "200..6348800"
        ::= { multicastPortEntry 9 }

    multicastPortUnknownMulticast  OBJECT-TYPE
        SYNTAX  INTEGER {
             drop(1),
             flooding(2)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Drop or flooding unknown multicast packets for each port"
        ::= { multicastPortEntry 10 }

-- multicastStatus
    multicastStatus        OBJECT IDENTIFIER ::= { mgs370012c 27 }

        multicastStatusTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF MulticastStatusEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { multicastStatus 1 }

    multicastStatusEntry OBJECT-TYPE
        SYNTAX    MulticastStatusEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in multicastStatusTable."
        INDEX              { multicastStatusVlanID, multicastStatusPort, multicastStatusGroup }
        ::= { multicastStatusTable 1 }

        MulticastStatusEntry ::=
          SEQUENCE {
            multicastStatusIndex    INTEGER,
            multicastStatusVlanID   INTEGER,
            multicastStatusPort     INTEGER,
            multicastStatusGroup    IpAddress,
            multicastStatusTimeout  INTEGER,
            multicastStatusUpTime   INTEGER
          }

        multicastStatusIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { multicastStatusEntry 1 }

        multicastStatusVlanID OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { multicastStatusEntry 2 }

        multicastStatusPort OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { multicastStatusEntry 3 }

        multicastStatusGroup OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { multicastStatusEntry 4 }

        multicastStatusTimeout OBJECT-TYPE
        SYNTAX  INTEGER
        UNITS   "seconds"
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { multicastStatusEntry 5 }

        multicastStatusUpTime OBJECT-TYPE
        SYNTAX  INTEGER
        UNITS   "seconds"
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { multicastStatusEntry 6 }



      multicastVlanStatusTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF MulticastVlanStatusEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { multicastStatus 2 }

-- multicastVlanStatusTable
    multicastVlanStatusEntry OBJECT-TYPE
        SYNTAX    MulticastVlanStatusEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in multicastVlanStatusTable."
        INDEX              { multicastVlanStatusVlanID }
        ::= { multicastVlanStatusTable 1 }

        MulticastVlanStatusEntry ::=
        SEQUENCE {
            multicastVlanStatusVlanID    INTEGER,
            multicastVlanStatusType      INTEGER,
            multicastVlanQueryPort       PortList

         }

        multicastVlanStatusVlanID OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { multicastVlanStatusEntry 1 }

        multicastVlanStatusType OBJECT-TYPE
        SYNTAX  INTEGER {
           dynamic(1),
         mvr (2),
        static(3)

        }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { multicastVlanStatusEntry 2 }

        multicastVlanQueryPort OBJECT-TYPE
        SYNTAX  PortList
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { multicastVlanStatusEntry 3 }

-- igmpSnpCountStatus

        igmpSnpCountStatus    OBJECT IDENTIFIER
        ::= { multicastStatus 3 }

 -- igmpSnpV2CountTable


        igmpSnpV2CountQueryRx OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { igmpSnpCountStatus 1 }

        igmpSnpV2CountReportRx OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { igmpSnpCountStatus 2 }

        igmpSnpV2CountLeaveRx OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { igmpSnpCountStatus 3 }

        igmpSnpV2CountQueryRxDrop OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { igmpSnpCountStatus 4 }

        igmpSnpV2CountReportRxDrop OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { igmpSnpCountStatus 5 }

        igmpSnpV2CountLeaveRxDrop OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { igmpSnpCountStatus 6 }

        igmpSnpV2CountQueryTx OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { igmpSnpCountStatus 7 }

        igmpSnpV2CountReportTx OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { igmpSnpCountStatus 8 }

        igmpSnpV2CountLeaveTx OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { igmpSnpCountStatus 9 }

       --  igmpSnpV3CountTable


        igmpSnpV3CountQueryRx OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { igmpSnpCountStatus 10 }

        igmpSnpV3CountReportRx OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { igmpSnpCountStatus 11 }


        igmpSnpV3CountQueryRxDrop OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { igmpSnpCountStatus 12 }

        igmpSnpV3CountReportRxDrop OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { igmpSnpCountStatus 13 }


        igmpSnpV3CountQueryTx OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { igmpSnpCountStatus 14 }

        igmpSnpV3CountReportTx OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { igmpSnpCountStatus 15 }

  --  igmpSnpCountVlanStatus
       igmpSnpCountVlanTable OBJECT-TYPE
        SYNTAX SEQUENCE OF IgmpSnpCountVlanEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION    ""

       ::= { multicastStatus 4}

       igmpSnpCountVlanEntry OBJECT-TYPE
        SYNTAX    IgmpSnpCountVlanEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in igmpGroupVlanStatus."
        INDEX              { igmpSnpCountVlanIndex }
        ::= { igmpSnpCountVlanTable 1 }

        IgmpSnpCountVlanEntry ::=
        SEQUENCE {
            igmpSnpCountVlanIndex    INTEGER,
            igmpSnpV2CountVlanQueryRx    INTEGER,
            igmpSnpV2CountVlanReportRx INTEGER,
            igmpSnpV2CountVlanLeaveRx INTEGER,
            igmpSnpV2CountVlanQueryRxDrop INTEGER,
            igmpSnpV2CountVlanReportRxDrop INTEGER,
            igmpSnpV2CountVlanLeaveRxDrop INTEGER,
            igmpSnpV2CountVlanQueryTx INTEGER,
            igmpSnpV2CountVlanReportTx INTEGER,
            igmpSnpV2CountVlanLeaveTx INTEGER,
            igmpSnpV3CountVlanQueryRx    INTEGER,
            igmpSnpV3CountVlanReportRx INTEGER,
            igmpSnpV3CountVlanQueryRxDrop INTEGER,
            igmpSnpV3CountVlanReportRxDrop INTEGER,
            igmpSnpV3CountVlanQueryTx INTEGER,
            igmpSnpV3CountVlanReportTx INTEGER


         }


       igmpSnpCountVlanIndex OBJECT-TYPE
       SYNTAX    INTEGER
       ACCESS     read-only
       STATUS    mandatory
       DESCRIPTION    "Input vlan"
       ::={ igmpSnpCountVlanEntry 1}

       igmpSnpV2CountVlanQueryRx OBJECT-TYPE
       SYNTAX    INTEGER
       ACCESS     read-only
       STATUS    mandatory
       DESCRIPTION    "show igmpsnp Query Rx counters for vlan"
       ::={ igmpSnpCountVlanEntry 2}

       igmpSnpV2CountVlanReportRx OBJECT-TYPE
       SYNTAX    INTEGER
       ACCESS     read-only
       STATUS    mandatory
       DESCRIPTION    "show igmpsnp Report Rx counters for vlan"
       ::={ igmpSnpCountVlanEntry 3}

       igmpSnpV2CountVlanLeaveRx OBJECT-TYPE
       SYNTAX    INTEGER
       ACCESS     read-only
       STATUS    mandatory
       DESCRIPTION    "show igmpsnp Leave Rx counters for vlan"
       ::={ igmpSnpCountVlanEntry 4}

       igmpSnpV2CountVlanQueryRxDrop OBJECT-TYPE
       SYNTAX    INTEGER
       ACCESS     read-only
       STATUS    mandatory
       DESCRIPTION    "show igmpsnp Query Rx Error counters for vlan"
       ::={ igmpSnpCountVlanEntry 5}

       igmpSnpV2CountVlanReportRxDrop OBJECT-TYPE
       SYNTAX    INTEGER
       ACCESS     read-only
       STATUS    mandatory
       DESCRIPTION    "show igmpsnp Report Rx Error counters for vlan"
       ::={ igmpSnpCountVlanEntry 6}

       igmpSnpV2CountVlanLeaveRxDrop OBJECT-TYPE
       SYNTAX    INTEGER
       ACCESS     read-only
       STATUS    mandatory
       DESCRIPTION    "show igmpsnp Leave Rx Error counters for vlan"
       ::={ igmpSnpCountVlanEntry 7}

       igmpSnpV2CountVlanQueryTx OBJECT-TYPE
       SYNTAX    INTEGER
       ACCESS     read-only
       STATUS    mandatory
       DESCRIPTION    "show igmpsnp Query Tx counters for vlan"
       ::={ igmpSnpCountVlanEntry 8}

       igmpSnpV2CountVlanReportTx OBJECT-TYPE
       SYNTAX    INTEGER
       ACCESS     read-only
       STATUS    mandatory
       DESCRIPTION    "show igmpsnp Report Tx counters for vlan"
       ::={ igmpSnpCountVlanEntry 9}

       igmpSnpV2CountVlanLeaveTx OBJECT-TYPE
       SYNTAX    INTEGER
       ACCESS     read-only
       STATUS    mandatory
       DESCRIPTION    "show igmpsnp Leave Tx counters for vlan"
       ::={ igmpSnpCountVlanEntry 10}


        igmpSnpV3CountVlanQueryRx OBJECT-TYPE
       SYNTAX    INTEGER
       ACCESS     read-only
       STATUS    mandatory
       DESCRIPTION    "show igmpsnp Query Rx counters for vlan"
       ::={ igmpSnpCountVlanEntry 11}

       igmpSnpV3CountVlanReportRx OBJECT-TYPE
       SYNTAX    INTEGER
       ACCESS     read-only
       STATUS    mandatory
       DESCRIPTION    "show igmpsnp Report Rx counters for vlan"
       ::={ igmpSnpCountVlanEntry 12}


       igmpSnpV3CountVlanQueryRxDrop OBJECT-TYPE
       SYNTAX    INTEGER
       ACCESS     read-only
       STATUS    mandatory
       DESCRIPTION    "show igmpsnp Query Rx Error counters for vlan"
       ::={ igmpSnpCountVlanEntry 13}

       igmpSnpV3CountVlanReportRxDrop OBJECT-TYPE
       SYNTAX    INTEGER
       ACCESS     read-only
       STATUS    mandatory
       DESCRIPTION    "show igmpsnp Report Rx Error counters for vlan"
       ::={ igmpSnpCountVlanEntry 14}


       igmpSnpV3CountVlanQueryTx OBJECT-TYPE
       SYNTAX    INTEGER
       ACCESS     read-only
       STATUS    mandatory
       DESCRIPTION    "show igmpsnp Query Tx counters for vlan"
       ::={ igmpSnpCountVlanEntry 15}

       igmpSnpV3CountVlanReportTx OBJECT-TYPE
       SYNTAX    INTEGER
       ACCESS     read-only
       STATUS    mandatory
       DESCRIPTION    "show igmpsnp Report Tx counters for vlan"
       ::={ igmpSnpCountVlanEntry 16}





 --igmpSnpCountPortStatus
        igmpSnpCountPortTable OBJECT-TYPE
        SYNTAX SEQUENCE OF IgmpSnpCountPortEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION    ""

       ::= { multicastStatus 5}

         igmpSnpCountPortEntry OBJECT-TYPE
        SYNTAX    IgmpSnpCountPortEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in igmpSnpCountPortStatus."
        INDEX              { dot1dBasePort }
        ::= { igmpSnpCountPortTable 1 }

        IgmpSnpCountPortEntry ::=
          SEQUENCE {
               igmpSnpV2CountPortQueryRx    INTEGER,
               igmpSnpV2CountPortReportRx INTEGER,
               igmpSnpV2CountPortLeaveRx INTEGER,
               igmpSnpV2CountPortReportRxDrop INTEGER,
               igmpSnpV2CountPortLeaveRxDrop INTEGER,
               igmpSnpV2CountPortReportTx INTEGER,
               igmpSnpV2CountPortLeaveTx INTEGER,
               igmpSnpV3CountPortQueryRx    INTEGER,
               igmpSnpV3CountPortReportRx INTEGER,
               igmpSnpV3CountPortReportRxDrop INTEGER,
               igmpSnpV3CountPortReportTx INTEGER
          }




       igmpSnpV2CountPortQueryRx  OBJECT-TYPE
       SYNTAX    INTEGER
       ACCESS     read-only
       STATUS    mandatory
       DESCRIPTION    "show igmpsnp Query Rx counters for port"
       ::={ igmpSnpCountPortEntry 1}

       igmpSnpV2CountPortReportRx  OBJECT-TYPE
       SYNTAX    INTEGER
       ACCESS     read-only
       STATUS    mandatory
       DESCRIPTION    "show igmpsnp Report Rx counters for port"
       ::={ igmpSnpCountPortEntry 2}

       igmpSnpV2CountPortLeaveRx  OBJECT-TYPE
       SYNTAX    INTEGER
       ACCESS     read-only
       STATUS    mandatory
       DESCRIPTION    "show igmpsnp Leave Rx counters for port"
       ::={ igmpSnpCountPortEntry 3}

       igmpSnpV2CountPortReportRxDrop  OBJECT-TYPE
       SYNTAX    INTEGER
       ACCESS     read-only
       STATUS    mandatory
       DESCRIPTION    "show igmpsnp Report Rx Error counters for port"
       ::={ igmpSnpCountPortEntry 4}

       igmpSnpV2CountPortLeaveRxDrop  OBJECT-TYPE
       SYNTAX    INTEGER
       ACCESS     read-only
       STATUS    mandatory
       DESCRIPTION    "show igmpsnp Leave Rx Error counters for port"
       ::={ igmpSnpCountPortEntry 5}

       igmpSnpV2CountPortReportTx  OBJECT-TYPE
       SYNTAX    INTEGER
       ACCESS     read-only
       STATUS    mandatory
       DESCRIPTION    "show igmpsnp Report Tx counters for port"
       ::={ igmpSnpCountPortEntry 6}

       igmpSnpV2CountPortLeaveTx  OBJECT-TYPE
       SYNTAX    INTEGER
       ACCESS     read-only
       STATUS    mandatory
       DESCRIPTION    "show igmpsnp Leave Tx counters for port"
       ::={ igmpSnpCountPortEntry 7}


       igmpSnpV3CountPortQueryRx  OBJECT-TYPE
       SYNTAX    INTEGER
       ACCESS     read-only
       STATUS    mandatory
       DESCRIPTION    "show igmpsnp Query Rx counters for port"
       ::={ igmpSnpCountPortEntry 8}

       igmpSnpV3CountPortReportRx  OBJECT-TYPE
       SYNTAX    INTEGER
       ACCESS     read-only
       STATUS    mandatory
       DESCRIPTION    "show igmpsnp Report Rx counters for port"
       ::={ igmpSnpCountPortEntry 9}


       igmpSnpV3CountPortReportRxDrop  OBJECT-TYPE
       SYNTAX    INTEGER
       ACCESS     read-only
       STATUS    mandatory
       DESCRIPTION    "show igmpsnp Report Rx Error counters for port"
       ::={ igmpSnpCountPortEntry 10}


       igmpSnpV3CountPortReportTx  OBJECT-TYPE
       SYNTAX    INTEGER
       ACCESS     read-only
       STATUS    mandatory
       DESCRIPTION    "show igmpsnp Report Tx counters for port"
       ::={ igmpSnpCountPortEntry 11}











-- igmpSnpGroupCountStatus
         igmpSnpGroupCountStatus OBJECT IDENTIFIER
        ::= { multicastStatus 6 }

        igmpSnpGroupCountNum OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION    "Show total IGMP snooping group number"
        ::= { igmpSnpGroupCountStatus 1 }


-- igmpGroupCountVlanTable
        igmpSnpGroupCountVlanTable OBJECT-TYPE
        SYNTAX SEQUENCE OF IgmpSnpGroupCountVlanEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION    ""
        ::= { igmpSnpGroupCountStatus 2}

        igmpSnpGroupCountVlanEntry OBJECT-TYPE
        SYNTAX    IgmpSnpGroupCountVlanEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in igmpSnpGroupVlanStatus."
        INDEX              { igmpSnpGroupCountVlanIndex }
        ::= { igmpSnpGroupCountVlanTable 1 }

        IgmpSnpGroupCountVlanEntry ::=
        SEQUENCE {
            igmpSnpGroupCountVlanIndex    INTEGER,
            igmpSnpGroupCountVlanNum    INTEGER
         }



        igmpSnpGroupCountVlanIndex OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Show IGMP snooping group index for vlan"
        ::= {  igmpSnpGroupCountVlanEntry 1}

        igmpSnpGroupCountVlanNum OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Show IGMP snooping group number for vlan"
        ::={  igmpSnpGroupCountVlanEntry 2}

--      igmpGroupCountPortTable
        igmpSnpGroupCountPortTable OBJECT-TYPE
        SYNTAX SEQUENCE OF IgmpSnpGroupCountPortEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION    ""

        ::= {igmpSnpGroupCountStatus 3}

        igmpSnpGroupCountPortEntry OBJECT-TYPE
        SYNTAX    IgmpSnpGroupCountPortEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in igmpGroupCountPortStatus."
        INDEX              { dot1dBasePort }
        ::= { igmpSnpGroupCountPortTable 1 }

        IgmpSnpGroupCountPortEntry ::=
            SEQUENCE {
                   igmpSnpGroupCountPortNum    INTEGER
            }



        igmpSnpGroupCountPortNum OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Show IGMP snooping group number for port"
        ::={  igmpSnpGroupCountPortEntry 1}

--    igmpSnpGroupClient
        igmpSnpGroupClientTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF IgmpSnpGroupClientEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { multicastStatus 7 }

        igmpSnpGroupClientEntry    OBJECT-TYPE
        SYNTAX    IgmpSnpGroupClientEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in igmpSnpGroupClientTable."
        INDEX              { igmpSnpGroupClientVlanID, igmpSnpGroupClientPort, igmpSnpGroupClientGroup, igmpSnpGroupClientIp }
        ::= { igmpSnpGroupClientTable 1 }

        IgmpSnpGroupClientEntry ::=
        SEQUENCE {
            igmpSnpGroupClientGroup       IpAddress,
            igmpSnpGroupClientVlanID      INTEGER,
            igmpSnpGroupClientPort        INTEGER,
            igmpSnpGroupClientIp          IpAddress
         }

        igmpSnpGroupClientGroup OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "Multicast group address"
        ::= { igmpSnpGroupClientEntry 1 }

        igmpSnpGroupClientVlanID OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "The vlan where the multicast traffic runs"
        ::= { igmpSnpGroupClientEntry 2 }

        igmpSnpGroupClientPort OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "The port where hosts connect to the swtich"
        ::= { igmpSnpGroupClientEntry 3 }

        igmpSnpGroupClientIp OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "The hosts that are interested in the multicast group"
        ::= { igmpSnpGroupClientEntry 4 }

--  igmpSnpGroupStatus
         igmpSnpGroupStatus OBJECT IDENTIFIER
        ::= { multicastStatus 8 }

--  igmpSnpGroupTable
        igmpSnpGroupTable OBJECT-TYPE
        SYNTAX SEQUENCE OF IgmpSnpGroupEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION    ""
        ::= { igmpSnpGroupStatus 1}

        igmpSnpGroupEntry OBJECT-TYPE
        SYNTAX    IgmpSnpGroupEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in igmpSnpGroupStatus."
        INDEX              { igmpSnpGroupVlanID, igmpSnpGroupAddress }
        ::= { igmpSnpGroupTable 1 }

        IgmpSnpGroupEntry ::=
        SEQUENCE {
            igmpSnpGroupVlanID    INTEGER,
            igmpSnpGroupAddress   IpAddress,
            igmpSnpGroupPortCount INTEGER,
            igmpSnpGroupPortList  PortList
         }

        igmpSnpGroupVlanID OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "show IGMP snooping group vlan for vlan and group"
        ::= {  igmpSnpGroupEntry 1}

        igmpSnpGroupAddress OBJECT-TYPE
        SYNTAX IpAddress
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "show IGMP snooping group address for vlan and group"
        ::={  igmpSnpGroupEntry 2}

        igmpSnpGroupPortCount OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "show IGMP snooping group port count for vlan and group"
        ::={  igmpSnpGroupEntry 3}

        igmpSnpGroupPortList OBJECT-TYPE
        SYNTAX PortList
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "show IGMP snooping group port list for vlan and group"
        ::={  igmpSnpGroupEntry 4}

--  igmpFilteringProfileSetup
    igmpFilteringProfileSetup         OBJECT IDENTIFIER ::= { mgs370012c 28 }

    igmpFilteringMaxNumberOfProfile OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { igmpFilteringProfileSetup 1 }

        igmpFilteringProfileTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF IgmpFilteringProfileEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { igmpFilteringProfileSetup 2 }

    igmpFilteringProfileEntry OBJECT-TYPE
        SYNTAX    IgmpFilteringProfileEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in igmpFilteringProfileTable."
        INDEX              { igmpFilteringProfileName, igmpFilteringProfileStartAddress, igmpFilteringProfileEndAddress }
        ::= { igmpFilteringProfileTable 1 }

        IgmpFilteringProfileEntry ::=
        SEQUENCE {
            igmpFilteringProfileName            DisplayString,
            igmpFilteringProfileStartAddress    IpAddress,
            igmpFilteringProfileEndAddress      IpAddress,
            igmpFilteringProfileRowStatus       RowStatus
        }

        igmpFilteringProfileName OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { igmpFilteringProfileEntry 1 }

        igmpFilteringProfileStartAddress OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { igmpFilteringProfileEntry 2 }

        igmpFilteringProfileEndAddress OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { igmpFilteringProfileEntry 3 }

        igmpFilteringProfileRowStatus OBJECT-TYPE
        SYNTAX  RowStatus
        ACCESS  read-create
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { igmpFilteringProfileEntry 4 }

--  MVRSetup
    mvrSetup         OBJECT IDENTIFIER ::= { mgs370012c 29 }

    maxNumberOfMVR OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { mvrSetup 1 }

        mvrTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF MvrEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { mvrSetup 2 }

    mvrEntry OBJECT-TYPE
        SYNTAX    MvrEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in mvrTable."
        INDEX              { mvrVlanID }
        ::= { mvrTable 1 }

        MvrEntry ::=
        SEQUENCE {
            mvrVlanID           INTEGER,
            mvrName             DisplayString,
            mvrMode             INTEGER,
            mvrRowStatus        RowStatus,
            mvr8021pPriority    INTEGER
        }

        mvrVlanID OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "1..4094"
        ::= { mvrEntry 1 }

        mvrName OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { mvrEntry 2 }

        mvrMode OBJECT-TYPE
        SYNTAX  INTEGER {
            dynamic(0),
            compatible(1)
            }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { mvrEntry 3 }

        mvrRowStatus OBJECT-TYPE
        SYNTAX  RowStatus
        ACCESS  read-create
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { mvrEntry 4 }

        mvr8021pPriority OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Set the 802.1p priority of control messages within MVR (0~7)"
        ::= { mvrEntry 5 }

        mvrPortTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF MvrPortEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { mvrSetup 3 }

    mvrPortEntry OBJECT-TYPE
        SYNTAX    MvrPortEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in mvrPortTable."
        INDEX              { mvrVlanID, dot1dBasePort }
        ::= { mvrPortTable 1 }

        MvrPortEntry ::=
        SEQUENCE {
            mvrPortRole    INTEGER,
            mvrPortTagging    EnabledStatus
        }

        mvrPortRole OBJECT-TYPE
        SYNTAX  INTEGER {
            none(1),
            source-port(2),
            receiver-port(3)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { mvrPortEntry 1 }

        mvrPortTagging OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { mvrPortEntry 2 }

    maxNumberOfMvrGroup OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { mvrSetup 4 }

        mvrGroupTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF MvrGroupEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { mvrSetup 5 }

    mvrGroupEntry OBJECT-TYPE
        SYNTAX    MvrGroupEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in mvrGroupTable."
        INDEX              { mvrVlanID, mvrGroupName }
        ::= { mvrGroupTable 1 }

        MvrGroupEntry ::=
        SEQUENCE {
            mvrGroupName        DisplayString,
            mvrGroupStartAddress    IpAddress,
            mvrGroupEndAddress    IpAddress,
            mvrGroupRowStatus    RowStatus
        }

        mvrGroupName OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { mvrGroupEntry 1 }

        mvrGroupStartAddress OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { mvrGroupEntry 2 }

        mvrGroupEndAddress OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { mvrGroupEntry 3 }

        mvrGroupRowStatus OBJECT-TYPE
        SYNTAX  RowStatus
        ACCESS  read-create
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { mvrGroupEntry 4 }

-- clusterSetup
    clusterSetup         OBJECT IDENTIFIER ::= { mgs370012c 30 }

-- clusterManager
    clusterManager         OBJECT IDENTIFIER ::= { clusterSetup 1 }

        clusterMaxNumOfManager OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { clusterManager 1 }

-- clusterManagerTable
        clusterManagerTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF ClusterManagerEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { clusterManager 2 }

    clusterManagerEntry OBJECT-TYPE
        SYNTAX    ClusterManagerEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in clusterManagerTable."
        INDEX              { clusterManagerVid }
        ::= { clusterManagerTable 1 }

        ClusterManagerEntry ::=
           SEQUENCE {
            clusterManagerVid    INTEGER,
            clusterManagerName    DisplayString,
            clusterManagerRowStatus    RowStatus
           }

        clusterManagerVid OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { clusterManagerEntry 1 }

        clusterManagerName OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { clusterManagerEntry 2 }

        clusterManagerRowStatus OBJECT-TYPE
        SYNTAX  RowStatus
        ACCESS  read-create
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { clusterManagerEntry 3 }

-- clusterMembers
    clusterMembers         OBJECT IDENTIFIER ::= { clusterSetup 2 }

        clusterMaxNumOfMember OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { clusterMembers 1 }

-- clusterMemberTable
        clusterMemberTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF ClusterMemberEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { clusterMembers 2 }

    clusterMemberEntry OBJECT-TYPE
        SYNTAX    ClusterMemberEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in clusterMemberTable."
        INDEX              { clusterMemberMac }
        ::= { clusterMemberTable 1 }

        ClusterMemberEntry ::=
           SEQUENCE {
            clusterMemberMac    MacAddress,
            clusterMemberName    DisplayString,
            clusterMemberModel    DisplayString,
            clusterMemberPassword    DisplayString,
            clusterMemberRowStatus    RowStatus
           }

        clusterMemberMac OBJECT-TYPE
        SYNTAX  MacAddress
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { clusterMemberEntry 1 }

        clusterMemberName OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { clusterMemberEntry 2 }

        clusterMemberModel OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { clusterMemberEntry 3 }

        clusterMemberPassword OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { clusterMemberEntry 4 }

        clusterMemberRowStatus OBJECT-TYPE
        SYNTAX  RowStatus
        ACCESS  read-create
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { clusterMemberEntry 5 }

-- clusterCandidates
    clusterCandidates         OBJECT IDENTIFIER ::= { clusterSetup 3 }

-- clusterCandidateTable
        clusterCandidateTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF ClusterCandidateEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { clusterCandidates 1 }

    clusterCandidateEntry OBJECT-TYPE
        SYNTAX    ClusterCandidateEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in clusterCandidateTable."
        INDEX              { clusterCandidateMac }
        ::= { clusterCandidateTable 1 }

        ClusterCandidateEntry ::=
           SEQUENCE {
            clusterCandidateMac    MacAddress,
            clusterCandidateName    DisplayString,
            clusterCandidateModel    DisplayString
           }

        clusterCandidateMac OBJECT-TYPE
        SYNTAX  MacAddress
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { clusterCandidateEntry 1 }

        clusterCandidateName OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { clusterCandidateEntry 2 }

        clusterCandidateModel OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { clusterCandidateEntry 3 }

-- clusterStatus
    clusterStatus         OBJECT IDENTIFIER ::= { clusterSetup 4 }

        clusterStatusRole OBJECT-TYPE
        SYNTAX  INTEGER {
            none(0),
            manager(1),
            member(2)
        }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { clusterStatus 1 }

        clusterStatusManager OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { clusterStatus 2 }

        clsuterStatusNumOfMember OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { clusterStatus 3 }

-- clusterStatusMemberTable
        clusterStatusMemberTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF ClusterStatusMemberEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { clusterStatus 4 }

    clusterStatusMemberEntry OBJECT-TYPE
        SYNTAX    ClusterStatusMemberEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in clusterStatusMemberTable."
        INDEX              { clusterStatusMemberMac }
        ::= { clusterStatusMemberTable 1 }

        ClusterStatusMemberEntry ::=
           SEQUENCE {
            clusterStatusMemberMac        MacAddress,
            clusterStatusMemberName        DisplayString,
            clusterStatusMemberModel    DisplayString,
            clusterStatusMemberStatus    INTEGER
           }

        clusterStatusMemberMac OBJECT-TYPE
        SYNTAX  MacAddress
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { clusterStatusMemberEntry 1 }

        clusterStatusMemberName OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { clusterStatusMemberEntry 2 }

        clusterStatusMemberModel OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { clusterStatusMemberEntry 3 }

        clusterStatusMemberStatus OBJECT-TYPE
        SYNTAX  INTEGER {
            error(0),
            online(1),
            offline(2)
        }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { clusterStatusMemberEntry 4 }

--  sysLogSetup
    sysLogSetup         OBJECT IDENTIFIER ::= { mgs370012c 31 }

    sysLogState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "sysLog enabled/disabled for the switch."
        ::= { sysLogSetup 1 }

--  sysLogTypeTable
           sysLogTypeTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF SysLogTypeEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { sysLogSetup 2 }

    sysLogTypeEntry OBJECT-TYPE
        SYNTAX    SysLogTypeEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in sysLogTypeTable."
        INDEX              { sysLogTypeIndex }
        ::= { sysLogTypeTable 1 }

        SysLogTypeEntry ::=
           SEQUENCE {
             sysLogTypeIndex        INTEGER,
            sysLogTypeName        DisplayString,
            sysLogTypeState        EnabledStatus,
            sysLogTypeFacility    INTEGER
           }

        sysLogTypeIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { sysLogTypeEntry 1 }

        sysLogTypeName OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { sysLogTypeEntry 2 }

        sysLogTypeState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { sysLogTypeEntry 3 }

       sysLogTypeFacility OBJECT-TYPE
        SYNTAX  INTEGER {
            local-user0(0),
            local-user1(1),
            local-user2(2),
            local-user3(3),
            local-user4(4),
            local-user5(5),
            local-user6(6),
            local-user7(7)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { sysLogTypeEntry 4 }

--  sysLogServerTable
           sysLogServerTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF SysLogServerEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { sysLogSetup 3 }

    sysLogServerEntry OBJECT-TYPE
        SYNTAX    SysLogServerEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in sysLogServerTable."
        INDEX              { sysLogServerAddress }
        ::= { sysLogServerTable 1 }

        SysLogServerEntry ::=
           SEQUENCE {
             sysLogServerAddress        IpAddress,
            sysLogServerLogLevel    INTEGER,
            sysLogServerRowStatus    RowStatus
           }

        sysLogServerAddress OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { sysLogServerEntry 1 }

        sysLogServerLogLevel OBJECT-TYPE
        SYNTAX  INTEGER {
            level0(0),
            level0-1(1),
            level0-2(2),
            level0-3(3),
            level0-4(4),
            level0-5(5),
            level0-6(6),
            level0-7(7)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { sysLogServerEntry 2 }

        sysLogServerRowStatus OBJECT-TYPE
        SYNTAX  RowStatus
        ACCESS  read-create
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { sysLogServerEntry 3 }

--  MRSTP
    mrstp         OBJECT IDENTIFIER ::= { mgs370012c 32 }

    mrstpSetup  OBJECT IDENTIFIER ::= { mrstp 1 }

    mrstpBridgeTable  OBJECT-TYPE
    SYNTAX    SEQUENCE OF MrstpBridgeEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                ""
        ::= { mrstpSetup 1 }

    mrstpBridgeEntry  OBJECT-TYPE
        SYNTAX    MrstpBridgeEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in mrstpBridgeTable."
        INDEX              { mrstpBridgeIndex }
        ::= { mrstpBridgeTable 1 }

        MrstpBridgeEntry ::=
           SEQUENCE {
               mrstpBridgeIndex                INTEGER,
               mrstpState                INTEGER,
             mrstpProtocolSpecification        INTEGER,
               mrstpPriority                INTEGER,
            mrstpTimeSinceTopologyChange        TimeTicks,
            mrstpTopChanges                Counter,
            mrstpDesignatedRoot            BridgeId,
            mrstpRootCost                INTEGER,
            mrstpRootPort                INTEGER,
            mrstpMaxAge                Timeout,
            mrstpHelloTime                Timeout,
            mrstpHoldTime                INTEGER,
            mrstpForwardDelay            Timeout,
            mrstpBridgeMaxAge            Timeout,
            mrstpBridgeHelloTime            Timeout,
            mrstpBridgeForwardDelay            Timeout
           }

          -- the dot1dStp group

          -- Implementation of the dot1dStp group is optional.  It is
          -- implemented by those bridges that support the Spanning Tree
          -- Protocol.

          mrstpBridgeIndex OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The tree index of the MRSTP."
              ::= { mrstpBridgeEntry 1 }

          mrstpState OBJECT-TYPE
            SYNTAX  EnabledStatus
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
                      "Enabled/disabled on the mrstp bridge."
        ::= { mrstpBridgeEntry 2 }

          mrstpProtocolSpecification OBJECT-TYPE
              SYNTAX  INTEGER {
                          unknown(1),
                          decLb100(2),
                          ieee8021d(3)
                      }
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "An indication of what version of the Spanning
                      Tree Protocol is being run.  The value
                      'decLb100(2)' indicates the DEC LANbridge 100
                      Spanning Tree protocol.  IEEE 802.1d
                      implementations will return 'ieee8021d(3)'.  If
                      future versions of the IEEE Spanning Tree Protocol
                      are released that are incompatible with the
                      current version a new value will be defined."
              ::= { mrstpBridgeEntry 3 }

          mrstpPriority OBJECT-TYPE
              SYNTAX  INTEGER (0..65535)
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                      "The value of the write-able portion of the Bridge
                      ID, i.e., the first two octets of the (8 octet
                      long) Bridge ID.  The other (last) 6 octets of the
                      Bridge ID are given by the value of
                      dot1dBaseBridgeAddress."
              REFERENCE
                      "IEEE 802.1D-1990: Section 4.5.3.7"
              ::= { mrstpBridgeEntry 4 }

          mrstpTimeSinceTopologyChange OBJECT-TYPE
              SYNTAX  TimeTicks
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The time (in hundredths of a second) since the
                      last time a topology change was detected by the
                      bridge entity."
              REFERENCE
                      "IEEE 802.1D-1990: Section 6.8.1.1.3"
              ::= { mrstpBridgeEntry 5 }

          mrstpTopChanges OBJECT-TYPE
              SYNTAX  Counter
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The total number of topology changes detected by
                      this bridge since the management entity was last
                      reset or initialized."
              REFERENCE
                      "IEEE 802.1D-1990: Section 6.8.1.1.3"
              ::= { mrstpBridgeEntry 6 }

          mrstpDesignatedRoot OBJECT-TYPE
              SYNTAX  BridgeId
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The bridge identifier of the root of the spanning
                      tree as determined by the Spanning Tree Protocol
                      as executed by this node.  This value is used as
                      the Root Identifier parameter in all Configuration
                      Bridge PDUs originated by this node."
              REFERENCE
                      "IEEE 802.1D-1990: Section 4.5.3.1"
              ::= { mrstpBridgeEntry 7 }

          mrstpRootCost OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The cost of the path to the root as seen from
                      this bridge."
              REFERENCE
                      "IEEE 802.1D-1990: Section 4.5.3.2"
              ::= { mrstpBridgeEntry 8 }

          mrstpRootPort OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The port number of the port which offers the
                      lowest cost path from this bridge to the root
                      bridge."
              REFERENCE
                      "IEEE 802.1D-1990: Section 4.5.3.3"
              ::= { mrstpBridgeEntry 9 }

          mrstpMaxAge OBJECT-TYPE
              SYNTAX  Timeout
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The maximum age of Spanning Tree Protocol
                      information learned from the network on any port
                      before it is discarded, in units of hundredths of
                      a second.  This is the actual value that this
                      bridge is currently using."
              REFERENCE
                      "IEEE 802.1D-1990: Section 4.5.3.4"
              ::= { mrstpBridgeEntry 10 }

          mrstpHelloTime OBJECT-TYPE
              SYNTAX  Timeout
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The amount of time between the transmission of
                      Configuration bridge PDUs by this node on any port
                      when it is the root of the spanning tree or trying
                      to become so, in units of hundredths of a second.
                      This is the actual value that this bridge is
                      currently using."
              REFERENCE
                      "IEEE 802.1D-1990: Section 4.5.3.5"
              ::= { mrstpBridgeEntry 11 }

          mrstpHoldTime OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "This time value determines the interval length
                      during which no more than two Configuration bridge
                      PDUs shall be transmitted by this node, in units
                      of hundredths of a second."
              REFERENCE
                      "IEEE 802.1D-1990: Section 4.5.3.14"
              ::= { mrstpBridgeEntry 12 }

          mrstpForwardDelay OBJECT-TYPE
              SYNTAX  Timeout
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "This time value, measured in units of hundredths
                      of a second, controls how fast a port changes its
                      spanning state when moving towards the Forwarding
                      state.  The value determines how long the port
                      stays in each of the Listening and Learning
                      states, which precede the Forwarding state.  This
                      value is also used, when a topology change has
                      been detected and is underway, to age all dynamic
                      entries in the Forwarding Database.  [Note that
                      this value is the one that this bridge is
                      currently using, in contrast to
                      mrstpBridgeForwardDelay which is the value that
                      this bridge and all others would start using
                      if/when this bridge were to become the root.]"
              REFERENCE
                      "IEEE 802.1D-1990: Section 4.5.3.6"
              ::= { mrstpBridgeEntry 13 }

          mrstpBridgeMaxAge OBJECT-TYPE
              SYNTAX  Timeout (600..4000)
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                      "The value that all bridges use for MaxAge when
                      this bridge is acting as the root.  Note that
                      802.1D-1990 specifies that the range for this
                      parameter is related to the value of
                      mrstpBridgeHelloTime. The granularity of this
                      timer is specified by 802.1D-1990 to be 1 second.
                      An agent may return a badValue error if a set is
                      attempted to a value which is not a whole number
                      of seconds."
              REFERENCE
                      "IEEE 802.1D-1990: Section 4.5.3.8"
              ::= { mrstpBridgeEntry 14 }

          mrstpBridgeHelloTime OBJECT-TYPE
              SYNTAX  Timeout (100..1000)
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                      "The value that all bridges use for HelloTime when
                      this bridge is acting as the root.  The
                      granularity of this timer is specified by 802.1D-
                      1990 to be 1 second.  An agent may return a
                      badValue error if a set is attempted to a value
                      which is not a whole number of seconds."
              REFERENCE
                      "IEEE 802.1D-1990: Section 4.5.3.9"
              ::= { mrstpBridgeEntry 15 }

          mrstpBridgeForwardDelay OBJECT-TYPE
              SYNTAX  Timeout (400..3000)
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                      "The value that all bridges use for ForwardDelay
                      when this bridge is acting as the root.  Note that
                      802.1D-1990 specifies that the range for this
                      parameter is related to the value of
                      mrstpBridgeMaxAge.  The granularity of this
                      timer is specified by 802.1D-1990 to be 1 second.
                      An agent may return a badValue error if a set is
                      attempted to a value which is not a whole number
                      of seconds."
              REFERENCE
                      "IEEE 802.1D-1990: Section 4.5.3.10"
              ::= { mrstpBridgeEntry 16 }

          -- The Spanning Tree Port Table

          mrstpPortTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF MrstpPortEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "A table that contains port-specific information
                      for the Spanning Tree Protocol."
              ::= { mrstpSetup 2 }

          mrstpPortEntry OBJECT-TYPE
              SYNTAX  MrstpPortEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "A list of information maintained by every port
                      about the Spanning Tree Protocol state for that
                      port."
              INDEX   { mrstpPort }
              ::= { mrstpPortTable 1 }

          MrstpPortEntry ::=
              SEQUENCE {
                  mrstpPort
                      INTEGER,
                  mrstpPortPriority
                      INTEGER,
                  mrstpPortState
                      INTEGER,
                  mrstpPortEnable
                      INTEGER,
                  mrstpPortPathCost
                      INTEGER,
                  mrstpPortDesignatedRoot
                      BridgeId,
                  mrstpPortDesignatedCost
                      INTEGER,
                  mrstpPortDesignatedBridge
                      BridgeId,
                  mrstpPortDesignatedPort
                      OCTET STRING,
                  mrstpPortForwardTransitions
                      Counter,
                  mrstpPortOnBridgeIndex
                      INTEGER,
                    mrstpPortAdminEdgePort
                      INTEGER,
                  mrstpPortOperEdgePort
                      INTEGER
              }

          mrstpPort OBJECT-TYPE
              SYNTAX  INTEGER (1..65535)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The port number of the port for which this entry
                      contains Spanning Tree Protocol management
                      information."
              REFERENCE
                      "IEEE 802.1D-1990: Section 6.8.2.1.2"
              ::= { mrstpPortEntry 1 }

          mrstpPortPriority OBJECT-TYPE
              SYNTAX  INTEGER (0..255)
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                      "The value of the priority field which is
                      contained in the first (in network byte order)
                      octet of the (2 octet long) Port ID.  The other
                      octet of the Port ID is given by the value of
                      mrstpPort."
              REFERENCE
                      "IEEE 802.1D-1990: Section 4.5.5.1"
              ::= { mrstpPortEntry 2 }

          mrstpPortState OBJECT-TYPE
              SYNTAX  INTEGER {
                          disabled(1),
                          blocking(2),
                          listening(3),
                          learning(4),
                          forwarding(5),
                          broken(6)
                      }
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The port's current state as defined by
                      application of the Spanning Tree Protocol.  This
                      state controls what action a port takes on
                      reception of a frame.  If the bridge has detected
                      a port that is malfunctioning it will place that
                      port into the broken(6) state.  For ports which
                      are disabled (see mrstpPortEnable), this object
                      will have a value of disabled(1)."
              REFERENCE
                      "IEEE 802.1D-1990: Section 4.5.5.2"
              ::= { mrstpPortEntry 3 }

          mrstpPortEnable OBJECT-TYPE
              SYNTAX  INTEGER {
                          enabled(1),
                          disabled(2)
                      }
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                      "The enabled/disabled status of the port."
              REFERENCE
                      "IEEE 802.1D-1990: Section 4.5.5.2"
              ::= { mrstpPortEntry 4 }

          mrstpPortPathCost OBJECT-TYPE
              SYNTAX  INTEGER (1..65535)
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                      "The contribution of this port to the path cost of
                      paths towards the spanning tree root which include
                      this port.  802.1D-1990 recommends that the
                      default value of this parameter be in inverse
                      proportion to the speed of the attached LAN."
              REFERENCE
                      "IEEE 802.1D-1990: Section 4.5.5.3"
              ::= { mrstpPortEntry 5 }

          mrstpPortDesignatedRoot OBJECT-TYPE
              SYNTAX  BridgeId
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The unique Bridge Identifier of the Bridge
                      recorded as the Root in the Configuration BPDUs
                      transmitted by the Designated Bridge for the
                      segment to which the port is attached."
              REFERENCE
                      "IEEE 802.1D-1990: Section 4.5.5.4"
              ::= { mrstpPortEntry 6 }

          mrstpPortDesignatedCost OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The path cost of the Designated Port of the
                      segment connected to this port.  This value is
                      compared to the Root Path Cost field in received
                      bridge PDUs."
              REFERENCE
                      "IEEE 802.1D-1990: Section 4.5.5.5"
              ::= { mrstpPortEntry 7 }

          mrstpPortDesignatedBridge OBJECT-TYPE
              SYNTAX  BridgeId
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The Bridge Identifier of the bridge which this
                      port considers to be the Designated Bridge for
                      this port's segment."
              REFERENCE
                      "IEEE 802.1D-1990: Section 4.5.5.6"
              ::= { mrstpPortEntry 8 }

          mrstpPortDesignatedPort OBJECT-TYPE
              SYNTAX  OCTET STRING (SIZE (2))
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The Port Identifier of the port on the Designated
                      Bridge for this port's segment."
              REFERENCE
                      "IEEE 802.1D-1990: Section 4.5.5.7"
              ::= { mrstpPortEntry 9 }

          mrstpPortForwardTransitions OBJECT-TYPE
              SYNTAX  Counter
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The number of times this port has transitioned
                      from the Learning state to the Forwarding state."
              ::= { mrstpPortEntry 10 }

          mrstpPortOnBridgeIndex OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                      "Indetify the bridge index that this port joined to in MRSTP."
              ::= { mrstpPortEntry 11 }
      mrstpPortAdminEdgePort OBJECT-TYPE
              SYNTAX  INTEGER {
                          true(1),
                          false(2)
                      }
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                      "    The administrative value of the Edge Port parameter.  A
                         value of true(1) indicates that this port should be
                         assumed as an edge-port, and a value of false(2) indicates
                         that this port should be assumed as a non-edge-port. "
              REFERENCE
                      "IEEE 802.1t clause 14.8.2, 18.3.3"
              ::= { mrstpPortEntry 12 }


          mrstpPortOperEdgePort OBJECT-TYPE
              SYNTAX  INTEGER {
                          true(1),
                          false(2)
                      }
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                        "    The operational value of the Edge Port parameter.  The
                        object is initialized to the value of the corresponding
                        instance of dot1dStpPortAdminEdgePort.  When the
                        corresponding instance of dot1dStpPortAdminEdgePort is
                        set, this object will be changed as well.  This object
                        will also be changed to false on reception of a BPDU."
              REFERENCE
                      "IEEE 802.1t clause 14.8.2, 18.3.4"
              ::= { mrstpPortEntry 13 }



--  MRSTP Trap
    mrstpNotifications         OBJECT IDENTIFIER ::= { mrstp 2 }

     newRoot NOTIFICATION-TYPE
      OBJECTS {
        mrstpBridgeIndex
      }
      STATUS  current
      DESCRIPTION
          ""
      ::= { mrstpNotifications 1 }

    topologyChange NOTIFICATION-TYPE
      OBJECTS {
        mrstpBridgeIndex
      }
      STATUS  current
      DESCRIPTION
          ""
      ::= { mrstpNotifications 2 }


--  classifierSetup
    classifierSetup         OBJECT IDENTIFIER ::= { mgs370012c 33 }

        classifierRuleTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF ClassifierRuleEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { classifierSetup 1 }

        classifierRuleEntry OBJECT-TYPE
        SYNTAX    ClassifierRuleEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in classifierRuleTable."
        INDEX              {classifierName }
        ::= { classifierRuleTable 1 }

        ClassifierRuleEntry ::=
        SEQUENCE {
            classifierName        DisplayString,
            classifierEnable    INTEGER,
            classifierPacketFormat INTEGER,
            classifierVlanId     INTEGER,
            classifier8021pPriority INTEGER,
            classifierEtherType INTEGER,
            classifierSrcMAC     MacAddress,
            classifierIncomingPort INTEGER,
            classifierDstMAC     MacAddress,
            classifierDSCP        INTEGER,
            classifierIpProtocol INTEGER,
            classifierEstablishOnly INTEGER,
            classifierSrcIp        IpAddress,
            classifierSrcIpMask    INTEGER,
            classifierSrcSocket INTEGER,
            classifierDstIp        IpAddress,
            classifierDstIpMask    INTEGER,
            classifierDstSocket INTEGER,
            classifierRowstatus RowStatus,
                    classifierIPv6DSCP    INTEGER,
                    classifierIPv6NextHeader        INTEGER,
                    classifierIPv6EstablishOnly        INTEGER,
                    classifierIPv6SrcIp        InetAddress,
                    classifierIPv6SrcIpPrefixLen        INTEGER,
                    classifierIPv6DstIp        InetAddress,
                    classifierIPv6DstIpPrefixLen        INTEGER
           }

        classifierName OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "Name of classifier rule."
        ::= { classifierRuleEntry 1 }

        classifierEnable OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "Classifier rule enabled/disabled."
        ::= { classifierRuleEntry 2 }

        classifierPacketFormat OBJECT-TYPE
        SYNTAX  INTEGER
        {
          all(1),
    ethernetII-untagged(2),
    ethernetII-tagged(3),
         ethernet802-3-untagged(4),
          ethernet802-3-tagged(5)
        }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "Packet format for classifier rule. All(1), 802.3 untagged(2), 802.3 tagged(3), EthernetII untagged(4), EthernetII tagged(5)."
        ::= { classifierRuleEntry 3 }

           classifierVlanId OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "Vlan id for classifer rule, 1~4094. Value 0 means any"
        ::= { classifierRuleEntry 4 }

           classifier8021pPriority OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "802.1p priority for classifier rule, 0~7. Value -1 means any"
        ::= { classifierRuleEntry 5 }

           classifierEtherType OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "Ether type for classifier rule, in decimal expression. Value 65535 means any"
        ::= { classifierRuleEntry 6 }

        classifierSrcMAC OBJECT-TYPE
        SYNTAX  MacAddress
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "Source mac address for classifier rule. 00:00:00:00:00:00 means any"
        ::= { classifierRuleEntry 7 }

        classifierIncomingPort OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "Incoming Port for classifier rule. Value 65536 means any"
        ::= { classifierRuleEntry 8 }

        classifierDstMAC OBJECT-TYPE
        SYNTAX  MacAddress
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "Destination mac address for classifier rule. 00:00:00:00:00:00 means any"
        ::= { classifierRuleEntry 9 }

        classifierDSCP OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "DSCP for classifier rule. Value -1 means any"
        ::= { classifierRuleEntry 10 }

        classifierIpProtocol OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "IP Protocol for classifier rule. Value 255 means any"
        ::= { classifierRuleEntry 11 }

        classifierEstablishOnly OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "IP Protocol for EstablishOnly in classifier rule"
        ::= { classifierRuleEntry 12 }

        classifierSrcIp OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "Source IP address for classifier rule. 0.0.0.0 means any"
        ::= { classifierRuleEntry 13 }

        classifierSrcIpMask OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "Source IP Mask for classifier rule."
        ::= { classifierRuleEntry 14 }

        classifierSrcSocket OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "Source Socket Number for classifier rule. Value 0 means any"
        ::= { classifierRuleEntry 15 }

        classifierDstIp OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "Destination IP address for classifier rule. 0.0.0.0 means any"
        ::= { classifierRuleEntry 16 }

        classifierDstIpMask OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "Destination IP Mask for classifier rule"
        ::= { classifierRuleEntry 17 }

        classifierDstSocket OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "Destination Socket Number for classifier rule. Value 0 means any"
        ::= { classifierRuleEntry 18 }

        classifierRowstatus OBJECT-TYPE
        SYNTAX  RowStatus
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "Row Status for classifier rule"
        ::= { classifierRuleEntry 19 }



        classifierIPv6DSCP    OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                       "DSCP for classifier rule. Value -1 means any."
        ::= { classifierRuleEntry 51 }

        classifierIPv6NextHeader    OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                        "IPv6 next header for classifier rule. Value 255 means any."
        ::= { classifierRuleEntry 52 }

        classifierIPv6EstablishOnly        OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                        "IPv6 protocol for EstablishOnly in classifier rule."
        ::= { classifierRuleEntry 53 }

        classifierIPv6SrcIp        OBJECT-TYPE
        SYNTAX    InetAddress
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                        "IPv6 source address for classifier rule. :: means any."
        ::= { classifierRuleEntry 54 }

        classifierIPv6SrcIpPrefixLen        OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                         "IPv6 Source address prefix length for classifier rule."
        ::= { classifierRuleEntry 55 }

        classifierIPv6DstIp        OBJECT-TYPE
        SYNTAX    InetAddress
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                        "IPv6 destination address for classifier rule. :: means any."
        ::= { classifierRuleEntry 56 }

        classifierIPv6DstIpPrefixLen    OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                        "IPv6 destination address prefix length for classifier rule."
        ::= { classifierRuleEntry 57 }

--  policySetup
    policySetup         OBJECT IDENTIFIER ::= { mgs370012c 34 }

        policyTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF PolicyEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { policySetup 1 }

        policyEntry OBJECT-TYPE
        SYNTAX    PolicyEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in policyTable."
        INDEX              {policyName }
        ::= { policyTable 1 }

        PolicyEntry ::=
        SEQUENCE {
            policyName            DisplayString,
            policyEnable        INTEGER,
            policyClassifier      DisplayString,
            policyEgressPort     INTEGER,
            policy8021pPriority INTEGER,
            policyDSCP          INTEGER,
            policyTOS           INTEGER,
            policyBandwidth     INTEGER,
            policyOutOfProfileDSCP   INTEGER,
            policyForwardingAction   INTEGER,
            policyPriorityAction     INTEGER,
            policyDiffServAction      INTEGER,
            policyOutgoingAction     BITS,
            policyMeteringEnable     INTEGER,
            policyOutOfProfileAction BITS,
            policyRowstatus          RowStatus
        }

        policyName OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "Name of policy rule."
        ::= { policyEntry 1 }

        policyEnable OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "Policy rule enabled/disabled."
        ::= { policyEntry 2 }

        policyClassifier OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "Classifier of policy rule."
        ::= { policyEntry 3 }


        policyEgressPort OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "Egress Port for policy rule"
        ::= { policyEntry 5 }


        policy8021pPriority OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "802.1p priority for policy rule, 0~7."
        ::= { policyEntry 7 }

        policyDSCP OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "DSCP for policy rule."
        ::= { policyEntry 8 }

        policyTOS OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "TOS for policy rule, 0~7"
        ::= { policyEntry 9 }

        policyBandwidth OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "Bandwidth for policy rule"
        ::= { policyEntry 10 }

        policyOutOfProfileDSCP OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "Out Of Profile DSCP for policy rule."
        ::= { policyEntry 11 }

        policyForwardingAction OBJECT-TYPE
        SYNTAX  INTEGER
        {
            no-change(1),
            discard-the-packet(2),
            do-not-drop-the-matching-frame-previously-marked-for-dopping(3)
        }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "Forwarding Action for policy rule"
        ::= { policyEntry 12 }

        policyPriorityAction OBJECT-TYPE
        SYNTAX  INTEGER
        {
            no-change(1),
            set-the-packets-802-1-priority(2),
            send-the-packet-to-priority-queue(3),
            replace-the-802-1-priority-field-with-the-IP-TOS-value(4)
        }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "Priority Action for policy rule"
        ::= { policyEntry 13}

        policyDiffServAction OBJECT-TYPE
        SYNTAX  INTEGER
        {
            no-change(1),
            set-the-packets-TOS-field(2),
            replace-the-IP-TOS-field-with-the-802-1-priority-value(3),
            set-the-Diffserv-Codepoint-field-in-the-frame(4)
        }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "DiffServ Action for policy rule"
        ::= { policyEntry 14}

        policyOutgoingAction OBJECT-TYPE
        SYNTAX    BITS {
            send-the-packet-to-the-mirror-port(0),
            send-the-packet-to-the-egress-port(1),
            send-the-matching-frames-to-the-egress-port(2),
            set-the-packets-VLAN-ID(3)
        }
        ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Outgoing Action for policy rule. Started bit is from MSB bit7 (bit7~bit0). "
        ::= { policyEntry 15 }

        policyMeteringEnable OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "Metering for Policy rule enabled/disabled."
        ::= { policyEntry 16 }

        policyOutOfProfileAction OBJECT-TYPE
        SYNTAX    BITS {
            drop-the-packet(0),
            change-the-DSCP-value(1),
            set-Out-Drop-Precedence(2),
            do-not-drop-the-matching-frame-previously-marked-for-dropping(3)
        }
        ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Out Of Profile Action for policy rule. Started bit is from MSB bit7 (bit7~bit0)."
        ::= { policyEntry 17 }

        policyRowstatus OBJECT-TYPE
        SYNTAX  RowStatus
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "Row Status for policy rule"
        ::= { policyEntry 18 }


--  radiusServerSetup
                radiusServerSetup         OBJECT IDENTIFIER ::= { mgs370012c 35 }

        radiusAuthServerSetup OBJECT IDENTIFIER ::= { radiusServerSetup 1 }

        radiusAuthServerMode OBJECT-TYPE
        SYNTAX  INTEGER{
                index-priority(1),
                        round-robin(2)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { radiusAuthServerSetup 1 }

        radiusAuthServerTimeout OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { radiusAuthServerSetup 2 }

-- radiusAuthServerTable
        radiusAuthServerTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF RadiusAuthServerEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { radiusAuthServerSetup 3 }

    radiusAuthServerEntry OBJECT-TYPE
        SYNTAX    RadiusAuthServerEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in radiusAuthServerTable."
        INDEX              { radiusAuthServerIndex }
        ::= { radiusAuthServerTable 1 }

        RadiusAuthServerEntry ::=
           SEQUENCE {
            radiusAuthServerIndex        INTEGER,
            radiusAuthServerIpAddr        IpAddress,
            radiusAuthServerUdpPort        INTEGER,
            radiusAuthServerSharedSecret    DisplayString
           }

        radiusAuthServerIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { radiusAuthServerEntry 1 }

        radiusAuthServerIpAddr OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { radiusAuthServerEntry 2 }

        radiusAuthServerUdpPort OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { radiusAuthServerEntry 3 }

        radiusAuthServerSharedSecret OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { radiusAuthServerEntry 4 }

        radiusAcctServerSetup OBJECT IDENTIFIER ::= { radiusServerSetup 2 }

        radiusAcctServerTimeout OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { radiusAcctServerSetup 1 }

-- radiusAcctServerTable
        radiusAcctServerTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF RadiusAcctServerEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { radiusAcctServerSetup 2 }

    radiusAcctServerEntry OBJECT-TYPE
        SYNTAX    RadiusAcctServerEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in radiusAcctServerTable."
        INDEX              { radiusAcctServerIndex }
        ::= { radiusAcctServerTable 1 }

        RadiusAcctServerEntry ::=
           SEQUENCE {
            radiusAcctServerIndex        INTEGER,
            radiusAcctServerIpAddr        IpAddress,
            radiusAcctServerUdpPort        INTEGER,
            radiusAcctServerSharedSecret    DisplayString
           }

        radiusAcctServerIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { radiusAcctServerEntry 1 }

        radiusAcctServerIpAddr OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { radiusAcctServerEntry 2 }

        radiusAcctServerUdpPort OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { radiusAcctServerEntry 3 }

        radiusAcctServerSharedSecret OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { radiusAcctServerEntry 4 }

--  tacacsServerSetup
    tacacsServerSetup         OBJECT IDENTIFIER ::= { mgs370012c 36 }

        tacacsAuthServerSetup OBJECT IDENTIFIER ::= { tacacsServerSetup 1 }

        tacacsAuthServerMode OBJECT-TYPE
        SYNTAX  INTEGER{
                index-priority(1),
        round-robin(2)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { tacacsAuthServerSetup 1 }

        tacacsAuthServerTimeout OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { tacacsAuthServerSetup 2 }

-- tacacsAuthServerTable
        tacacsAuthServerTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF TacacsAuthServerEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { tacacsAuthServerSetup 3 }

    tacacsAuthServerEntry OBJECT-TYPE
        SYNTAX    TacacsAuthServerEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in tacacsAuthServerTable."
        INDEX              { tacacsAuthServerIndex }
        ::= { tacacsAuthServerTable 1 }

        TacacsAuthServerEntry ::=
           SEQUENCE {
            tacacsAuthServerIndex        INTEGER,
            tacacsAuthServerIpAddr        IpAddress,
            tacacsAuthServerTcpPort        INTEGER,
            tacacsAuthServerSharedSecret    DisplayString
           }

        tacacsAuthServerIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { tacacsAuthServerEntry 1 }

        tacacsAuthServerIpAddr OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { tacacsAuthServerEntry 2 }

        tacacsAuthServerTcpPort OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { tacacsAuthServerEntry 3 }

        tacacsAuthServerSharedSecret OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { tacacsAuthServerEntry 4 }

        tacacsAcctServerSetup OBJECT IDENTIFIER ::= { tacacsServerSetup 2 }

        tacacsAcctServerTimeout OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { tacacsAcctServerSetup 1 }

-- tacacsAcctServerTable
        tacacsAcctServerTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF TacacsAcctServerEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { tacacsAcctServerSetup 2 }

    tacacsAcctServerEntry OBJECT-TYPE
        SYNTAX    TacacsAcctServerEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in tacacsAcctServerTable."
        INDEX              { tacacsAcctServerIndex }
        ::= { tacacsAcctServerTable 1 }

        TacacsAcctServerEntry ::=
           SEQUENCE {
            tacacsAcctServerIndex        INTEGER,
            tacacsAcctServerIpAddr        IpAddress,
            tacacsAcctServerTcpPort        INTEGER,
            tacacsAcctServerSharedSecret    DisplayString
           }

        tacacsAcctServerIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { tacacsAcctServerEntry 1 }

        tacacsAcctServerIpAddr OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { tacacsAcctServerEntry 2 }

        tacacsAcctServerTcpPort OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { tacacsAcctServerEntry 3 }

        tacacsAcctServerSharedSecret OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { tacacsAcctServerEntry 4 }

--  aaaSetup
    aaaSetup         OBJECT IDENTIFIER ::= { mgs370012c 37 }

        authenticationSetup OBJECT IDENTIFIER ::= { aaaSetup 1 }

-- authenticationTypeTable
        authenticationTypeTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF AuthenticationTypeEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { authenticationSetup 1 }

    authenticationTypeEntry OBJECT-TYPE
        SYNTAX    AuthenticationTypeEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in authenticationTypeTable."
        INDEX              { authenticationTypeName }
        ::= { authenticationTypeTable 1 }

        AuthenticationTypeEntry ::=
           SEQUENCE {
            authenticationTypeName    DisplayString,
            authenticationTypeMethodList    OCTET STRING
           }

        authenticationTypeName OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { authenticationTypeEntry 1 }

        authenticationTypeMethodList OBJECT-TYPE
        SYNTAX  OCTET STRING
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { authenticationTypeEntry 2 }

    accountingSetup          OBJECT IDENTIFIER ::= { aaaSetup 2 }
    accountingUpdatePeriod OBJECT-TYPE
    SYNTAX  Integer32
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                          ""
    ::= { accountingSetup 1 }

-- accountingTypeTable
        accountingTypeTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF AccountingTypeEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { accountingSetup 2 }

    accountingTypeEntry OBJECT-TYPE
        SYNTAX    AccountingTypeEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in accountingTypeTable."
        INDEX              { accountingTypeName }
        ::= { accountingTypeTable 1 }

        AccountingTypeEntry ::=
           SEQUENCE {
             accountingTypeName        DisplayString,
             accountingTypeActive        EnabledStatus,
             accountingTypeBroadcast        EnabledStatus,
             accountingTypeMode        INTEGER,
             accountingTypeMethod        INTEGER,
             accountingTypePrivilege        INTEGER
           }

    accountingTypeName OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                          ""
    ::= { accountingTypeEntry 1 }

    accountingTypeActive OBJECT-TYPE
    SYNTAX  EnabledStatus
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                          ""
    ::= { accountingTypeEntry 2 }

    accountingTypeBroadcast OBJECT-TYPE
    SYNTAX  EnabledStatus
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                          ""
    ::= { accountingTypeEntry 3 }

    accountingTypeMode OBJECT-TYPE
    SYNTAX  INTEGER{
        not-available(255),
                start-stop(1),
        stop-only(2)
    }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                          ""
    ::= { accountingTypeEntry 4 }

    accountingTypeMethod OBJECT-TYPE
    SYNTAX  INTEGER{
                radius(1),
        tacacs(2)
    }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                          ""
    ::= { accountingTypeEntry 5 }

    accountingTypePrivilege OBJECT-TYPE
    SYNTAX  INTEGER{
        not-available(255),
        privilege-0(0),
        privilege-1(1),
        privilege-2(2),
        privilege-3(3),
        privilege-4(4),
        privilege-5(5),
        privilege-6(6),
        privilege-7(7),
        privilege-8(8),
        privilege-9(9),
        privilege-10(10),
        privilege-11(11),
        privilege-12(12),
        privilege-13(13),
        privilege-14(14)
    }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                          ""
    ::= { accountingTypeEntry 6 }

        authorizationSetup          OBJECT IDENTIFIER ::= { aaaSetup 3 }

-- authorizationTypeTable
        authorizationTypeTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF AuthorizationTypeEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { authorizationSetup 1 }

       authorizationTypeEntry OBJECT-TYPE
        SYNTAX    AuthorizationTypeEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in authorizationTypeTable."
        INDEX              { authorizationTypeName }
        ::= { authorizationTypeTable 1 }

        AuthorizationTypeEntry ::=
           SEQUENCE {
             authorizationTypeName        DisplayString,
             authorizationTypeActive        EnabledStatus,
             authorizationTypeMethod        INTEGER
           }

    authorizationTypeName OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                          ""
    ::= { authorizationTypeEntry 1 }

    authorizationTypeActive OBJECT-TYPE
    SYNTAX  EnabledStatus
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                          ""
    ::= { authorizationTypeEntry 2 }

    authorizationTypeMethod OBJECT-TYPE
    SYNTAX  INTEGER{
        radius(1),
        tacacs(2)
    }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                          ""
    ::= { authorizationTypeEntry 3 }


---------------------------------------------------
--
--  vlan stacking
--
---------------------------------------------------
--  vlanStackSetup
    vlanStackSetup OBJECT IDENTIFIER ::= { mgs370012c 38 }

        vlanStackState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      "VLAN Stacking enabled/disabled for the switch."
        ::= { vlanStackSetup 1 }

  --      vlanStackTpid OBJECT-TYPE
  --      SYNTAX  INTEGER
   --     ACCESS  read-write
    --    STATUS  mandatory
     --   DESCRIPTION
      --                "SP TPID in hex format, e.g. 8100."
       -- ::= { vlanStackSetup 2 }

-- vlanStackPortTable

        vlanStackPortTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF VlanStackPortEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { vlanStackSetup 3 }

    vlanStackPortEntry OBJECT-TYPE
        SYNTAX    VlanStackPortEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in vlanStackPortTable."
        INDEX              { dot1dBasePort }
        ::= { vlanStackPortTable 1 }

        VlanStackPortEntry ::=
           SEQUENCE {
            vlanStackPortMode    INTEGER,
            vlanStackPortVid    INTEGER,
            vlanStackPortPrio    INTEGER,
            vlanStackTunnelPortTpid    INTEGER,
            vlanStackInnerTagPrio    INTEGER
           }

        vlanStackPortMode OBJECT-TYPE
        SYNTAX  INTEGER {
        normal(1),
        access(2),
        tunnel(3)
    }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Mode of the port. Set Normal to have the switch ignore frames received
                          (or transmitted) on this port with VLAN stacking tags.
                          Anything you configure in SPVID and Priority are ignored.
            Set Access mode to have the switch add the SP TPID tag to all incoming
            frames received on this port. Set Access  mode for ingress ports at the
            edge of the service provider's network. Set Tunnel mode (available for
            Gigabit ports only) for egress ports at the edge of the service provider's
            network. In order to support VLAN stacking on a port, the port must be able
            to allow frames of 1526 Bytes (1522 Bytes + 4 Bytes for the second tag)
            to pass through it. normal (1), Access (2),  tunnel (3)"
        ::= { vlanStackPortEntry 1 }

        vlanStackPortVid OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "VLAN ID used in service provider tag."
        ::= { vlanStackPortEntry 2 }

        vlanStackPortPrio OBJECT-TYPE
        SYNTAX  INTEGER {
                prioriry-0(0),
                prioriry-1(1),
                prioriry-2(2),
                prioriry-3(3),
                prioriry-4(4),
                prioriry-5(5),
                prioriry-6(6),
                prioriry-7(7)
        }

        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Priority value for service provider tag.
                          0 is the lowest priority level and 7 is the highest."
        ::= { vlanStackPortEntry 3 }

        vlanStackTunnelPortTpid OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Tunnel Port TPID in hex format, e.g. 8100."
        ::= { vlanStackPortEntry 4 }

        vlanStackInnerTagPrio OBJECT-TYPE
        SYNTAX  INTEGER {
                untrust(0),
                trust(1)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Copy the priority value of customer tag to service provider tag."
        ::= { vlanStackPortEntry 5 }

   -- selectiveQinQTable
        selectiveQinQTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF SelectiveQinQEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { vlanStackSetup 4 }

    selectiveQinQEntry OBJECT-TYPE
        SYNTAX    SelectiveQinQEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in selective qinq table"
        INDEX              { selectiveQinQPort, selectiveQinQCvid }
        ::= { selectiveQinQTable 1 }

        SelectiveQinQEntry ::=
           SEQUENCE {
               selectiveQinQName        DisplayString,
            selectiveQinQPort        INTEGER,
            selectiveQinQCvid        INTEGER,
            selectiveQinQSpvid        INTEGER,
            selectiveQinQPriority    INTEGER,
            selectiveQinQRowStatus    RowStatus
           }

        selectiveQinQName OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "The name of selective qinq entry"
        ::= { selectiveQinQEntry 1 }

        selectiveQinQPort OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                         "interface port id"
        ::= { selectiveQinQEntry 2 }

        selectiveQinQCvid OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                         "inner vid"
        ::= { selectiveQinQEntry 3 }

        selectiveQinQSpvid OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                         "outer vid"
        ::= { selectiveQinQEntry 4 }

        selectiveQinQPriority OBJECT-TYPE
        SYNTAX  INTEGER {
                no-change(-1),
                prioriry-0(0),
                prioriry-1(1),
                prioriry-2(2),
                prioriry-3(3),
                prioriry-4(4),
                prioriry-5(5),
                prioriry-6(6),
                prioriry-7(7)
        }

        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                         "priority"
        ::= { selectiveQinQEntry 5 }

        selectiveQinQRowStatus OBJECT-TYPE
        SYNTAX  RowStatus
        ACCESS  read-create
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { selectiveQinQEntry 6 }



-- diffservSetup
    diffservSetup         OBJECT IDENTIFIER ::= { mgs370012c 39 }

        diffservState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { diffservSetup 1 }

-- diffservMapTable
        diffservMapTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF DiffservMapEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { diffservSetup 2 }

    diffservMapEntry OBJECT-TYPE
        SYNTAX    DiffservMapEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in diffservMapTable."
        INDEX              { diffservMapDscp }
        ::= { diffservMapTable 1 }

        DiffservMapEntry ::=
           SEQUENCE {
            diffservMapDscp        INTEGER,
            diffservMapPriority    INTEGER
           }

        diffservMapDscp OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "0-63"
        ::= { diffservMapEntry 1 }

        diffservMapPriority OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "0-7"
        ::= { diffservMapEntry 2 }

-- diffservPortTable
        diffservPortTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF DiffservPortEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { diffservSetup 3 }

    diffservPortEntry OBJECT-TYPE
        SYNTAX    DiffservPortEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in diffservPortTable."
        INDEX              { dot1dBasePort }
        ::= { diffservPortTable 1 }

        DiffservPortEntry ::=
           SEQUENCE {
            diffservPortState    EnabledStatus
           }

        diffservPortState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { diffservPortEntry 1 }


--  protocol-based VLAN
    protoBasedVlanSetup         OBJECT IDENTIFIER ::= { mgs370012c 40 }

        protoBasedVlanTable  OBJECT-TYPE
        SYNTAX    SEQUENCE OF ProtoBasedVlanEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { protoBasedVlanSetup 1 }

    protoBasedVlanEntry  OBJECT-TYPE
        SYNTAX    ProtoBasedVlanEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in protoBasedVlanTable."
        INDEX              { protoBasedVlanPort, protoBasedVlanPacketType, protoBasedVlanEtherType }
        ::= { protoBasedVlanTable 1 }

        ProtoBasedVlanEntry ::=
           SEQUENCE {
            protoBasedVlanPort            INTEGER,
            protoBasedVlanPacketType    INTEGER,
            protoBasedVlanEtherType        INTEGER,
            protoBasedVlanName            DisplayString,
            protoBasedVlanVid            INTEGER,
            protoBasedVlanPriority        INTEGER,
            protoBasedVlanState            RowStatus
           }

        protoBasedVlanPort OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { protoBasedVlanEntry 1 }

        protoBasedVlanPacketType OBJECT-TYPE
        SYNTAX  INTEGER {
            etherII(1),
            snap(2),
            llc(3)
        }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { protoBasedVlanEntry 2 }

        protoBasedVlanEtherType OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { protoBasedVlanEntry 3 }

        protoBasedVlanName OBJECT-TYPE
        SYNTAX  DisplayString (SIZE (0..32))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { protoBasedVlanEntry 4 }

        protoBasedVlanVid OBJECT-TYPE
        SYNTAX  INTEGER (1..4094)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { protoBasedVlanEntry 5 }

        protoBasedVlanPriority OBJECT-TYPE
        SYNTAX  INTEGER (0..7)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { protoBasedVlanEntry 6 }

        protoBasedVlanState OBJECT-TYPE
        SYNTAX  RowStatus
        ACCESS  read-create
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { protoBasedVlanEntry 7 }

---------------------------------------------------
--
--  dhcp snooping
--
---------------------------------------------------

    dhcpSnp         OBJECT IDENTIFIER ::= { mgs370012c 100 }


--
--  dhcp snooping vlan table
--

        dhcpSnpVlanTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF DhcpSnpVlanEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { dhcpSnp 1 }

    dhcpSnpVlanEntry OBJECT-TYPE
        SYNTAX    DhcpSnpVlanEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        ""
        INDEX              { dhcpSnpVlanEntryVid }
        ::= { dhcpSnpVlanTable 1 }

        DhcpSnpVlanEntry ::=
    SEQUENCE {
            dhcpSnpVlanEntryVid        INTEGER,
            dhcpSnpVlanEntryEnable        EnabledStatus,
            dhcpSnpVlanEntryOption82Enable    EnabledStatus,
            dhcpSnpVlanEntryInfo        EnabledStatus
        }

        dhcpSnpVlanEntryVid OBJECT-TYPE
        SYNTAX  INTEGER (1..4094)
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { dhcpSnpVlanEntry 1 }

        dhcpSnpVlanEntryEnable OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { dhcpSnpVlanEntry 2 }

        dhcpSnpVlanEntryOption82Enable OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { dhcpSnpVlanEntry 3 }

        dhcpSnpVlanEntryInfo OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { dhcpSnpVlanEntry 4 }

--
--  dhcp snooping interface table
--

        dhcpSnpPortTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF DhcpSnpPortEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { dhcpSnp 2 }

    dhcpSnpPortEntry OBJECT-TYPE
        SYNTAX    DhcpSnpPortEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        ""
        INDEX              { dhcpSnpPortEntryPort }
        ::= { dhcpSnpPortTable 1 }

        DhcpSnpPortEntry ::=
    SEQUENCE {
            dhcpSnpPortEntryPort        INTEGER,
            dhcpSnpPortEntryTrust        EnabledStatus,
            dhcpSnpPortEntryRate        INTEGER
        }

        dhcpSnpPortEntryPort OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { dhcpSnpPortEntry 1 }

        dhcpSnpPortEntryTrust OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { dhcpSnpPortEntry 2 }

        dhcpSnpPortEntryRate OBJECT-TYPE
        SYNTAX  INTEGER (0..2048)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "0 means unlimited"
        ::= { dhcpSnpPortEntry 3 }
--
--  dhcp snooping binding table
--

        dhcpSnpBindTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF DhcpSnpBindEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { dhcpSnp 3 }

    dhcpSnpBindEntry OBJECT-TYPE
        SYNTAX    DhcpSnpBindEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        ""
        INDEX              { dhcpSnpBindEntryMac, dhcpSnpBindEntryVid }
        ::= { dhcpSnpBindTable 1 }

        DhcpSnpBindEntry ::=
    SEQUENCE {
            dhcpSnpBindEntryMac        MacAddress,
            dhcpSnpBindEntryVid        INTEGER,
            dhcpSnpBindEntryIP        IpAddress,
            dhcpSnpBindEntryLease        INTEGER,
            dhcpSnpBindEntryType        INTEGER,
            dhcpSnpBindEntryPort        INTEGER
        }

        dhcpSnpBindEntryMac OBJECT-TYPE
        SYNTAX  MacAddress
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { dhcpSnpBindEntry 1 }

        dhcpSnpBindEntryVid OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { dhcpSnpBindEntry 2 }

        dhcpSnpBindEntryIP OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { dhcpSnpBindEntry 3 }

        dhcpSnpBindEntryLease OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { dhcpSnpBindEntry 4 }

        dhcpSnpBindEntryType OBJECT-TYPE
        SYNTAX  INTEGER { dynamic(2) }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { dhcpSnpBindEntry 5 }

        dhcpSnpBindEntryPort OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { dhcpSnpBindEntry 6 }

--
--  dhcp snooping
--

    dhcpSnpEnable OBJECT-TYPE
    SYNTAX  EnabledStatus
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                  ""
    ::= { dhcpSnp 4 }

--
--  dhcp snooping database
--


    dhcpSnpDb         OBJECT IDENTIFIER ::= { dhcpSnp 5 }

    dhcpSnpDbAbort OBJECT-TYPE
    SYNTAX  INTEGER (1..65535)
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                  ""
    ::= { dhcpSnpDb 1 }

    dhcpSnpDbWriteDelay OBJECT-TYPE
    SYNTAX  INTEGER (1..65535)
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                  ""
    ::= { dhcpSnpDb 2 }

    dhcpSnpDbUrl OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (0..255))
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                  ""
    ::= { dhcpSnpDb 3 }

    dhcpSnpDbUrlRenew OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (0..255))
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                  ""
    ::= { dhcpSnpDb 4 }

    dhcpSnpDbStat         OBJECT IDENTIFIER ::= { dhcpSnpDb 5 }

    dhcpSnpDbStatClear OBJECT-TYPE
    SYNTAX  EnabledStatus
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                  ""
    ::= { dhcpSnpDbStat 1 }

    dhcpSnpDbStatAgentRunning OBJECT-TYPE
    SYNTAX  INTEGER { none(0), read(1), write(2) }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                  ""
    ::= { dhcpSnpDbStat 2 }

    dhcpSnpDbStatDelayExpiry OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                  ""
    ::= { dhcpSnpDbStat 3 }

    dhcpSnpDbStatAbortExpiry OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                  ""
    ::= { dhcpSnpDbStat 4 }

    dhcpSnpDbStatLastSuccTime OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                  ""
    ::= { dhcpSnpDbStat 5 }

    dhcpSnpDbStatLastFailTime OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                  ""
    ::= { dhcpSnpDbStat 6 }

    dhcpSnpDbStatLastFailReason OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                  ""
    ::= { dhcpSnpDbStat 7 }

    dhcpSnpDbStatTotalAttempt OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                  ""
    ::= { dhcpSnpDbStat 8 }

    dhcpSnpDbStatStartupFail OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                  ""
    ::= { dhcpSnpDbStat 9 }

    dhcpSnpDbStatSuccTrans OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                  ""
    ::= { dhcpSnpDbStat 10 }

    dhcpSnpDbStatFailTrans OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                  ""
    ::= { dhcpSnpDbStat 11 }

    dhcpSnpDbStatSuccRead OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                  ""
    ::= { dhcpSnpDbStat 12 }

    dhcpSnpDbStatFailRead OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                  ""
    ::= { dhcpSnpDbStat 13 }

    dhcpSnpDbStatSuccWrite OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                  ""
    ::= { dhcpSnpDbStat 14 }

    dhcpSnpDbStatFailWrite OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                  ""
    ::= { dhcpSnpDbStat 15 }

    dhcpSnpDbStatFirstSuccAccess OBJECT-TYPE
    SYNTAX  INTEGER { none(0), read(1), write(2) }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                  ""
    ::= { dhcpSnpDbStat 16 }

    dhcpSnpDbStatLastIgnoreBindCol OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                  "Last ignored: binding collision"
    ::= { dhcpSnpDbStat 17 }

    dhcpSnpDbStatLastIgnoreExpireLease OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                  "Last ignored: expired leases"
    ::= { dhcpSnpDbStat 18 }

    dhcpSnpDbStatLastIgnoreInvalidIntf OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                  "Last ignored: invalid interface"
    ::= { dhcpSnpDbStat 19 }

    dhcpSnpDbStatLastIgnoreUnsuppVlan OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                  "Last ignored: unsupported vlans"
    ::= { dhcpSnpDbStat 20 }

    dhcpSnpDbStatLastIgnoreParse OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                  "Last ignored: parsing error"
    ::= { dhcpSnpDbStat 21 }

    dhcpSnpDbStatTotalIgnoreBindCol OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                  "Total ignored: binding collision"
    ::= { dhcpSnpDbStat 22 }

    dhcpSnpDbStatTotalIgnoreExpireLease OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                  "Total ignored: expired leases"
    ::= { dhcpSnpDbStat 23 }

    dhcpSnpDbStatTotalIgnoreInvalidIntf OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                  "Total ignored: invalid interface"
    ::= { dhcpSnpDbStat 24 }

    dhcpSnpDbStatTotalIgnoreUnsuppVlan OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                  "Total ignored: unsupported vlans"
    ::= { dhcpSnpDbStat 25 }

    dhcpSnpDbStatTotalIgnoreParse OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                  "Total ignored: parsing error"
    ::= { dhcpSnpDbStat 26 }


    dhcpSnpDbStatFirstSuccessAccess OBJECT-TYPE
    SYNTAX INTEGER{
                none(0),
                read(1),
                write(2)
        }
    ACCESS read-only
    STATUS  mandatory
    DESCRIPTION
                  "First Success Access"
    ::={ dhcpSnpDbStat 27}

--
--  dhcp snooping dhcp vlan
--

    dhcpSnpDhcpVlan         OBJECT IDENTIFIER ::= { dhcpSnp 6 }

    dhcpSnpDhcpVlanVid OBJECT-TYPE
    SYNTAX  INTEGER (0..4094)
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                  "0: disable DHCP VLAN."
    ::= { dhcpSnpDhcpVlan 1 }



-- --------------------------------------------------------------
--
-- ip source guard
--
-- --------------------------------------------------------------

    ipsg OBJECT IDENTIFIER ::= { mgs370012c 101 }

        ipsgTable  OBJECT-TYPE
        SYNTAX    SEQUENCE OF IpsgEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { ipsg 1 }

    ipsgEntry  OBJECT-TYPE
        SYNTAX    IpsgEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        ""
        INDEX              { ipsgEntryMac, ipsgEntryVid }
        ::= { ipsgTable 1 }

        IpsgEntry ::=
           SEQUENCE {
            ipsgEntryMac        MacAddress,
            ipsgEntryVid        INTEGER,
            ipsgEntryIp            IpAddress,
            ipsgEntryLease        INTEGER,
            ipsgEntryType        INTEGER,
            ipsgEntryPort        INTEGER,
            ipsgEntryState        RowStatus
           }

        ipsgEntryMac OBJECT-TYPE
        SYNTAX  MacAddress
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { ipsgEntry 1 }

        ipsgEntryVid OBJECT-TYPE
        SYNTAX  INTEGER (1.. 4094)
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { ipsgEntry 2 }

        ipsgEntryIp OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { ipsgEntry 3 }

        ipsgEntryLease OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "second"
        ::= { ipsgEntry 4 }

        ipsgEntryType OBJECT-TYPE
        SYNTAX  INTEGER { static(1), dhcp(2) }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { ipsgEntry 5 }

        ipsgEntryPort OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "0 means any port"
        ::= { ipsgEntry 6 }

        ipsgEntryState OBJECT-TYPE
        SYNTAX  RowStatus
        ACCESS  read-create
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { ipsgEntry 7 }

-- --------------------------------------------------------------
--
-- arpInspect
--
-- --------------------------------------------------------------

    arpInspect         OBJECT IDENTIFIER ::= { mgs370012c 102 }

    arpInspectSetup  OBJECT IDENTIFIER ::= { arpInspect 1 }

        arpInspectState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { arpInspectSetup 1 }

        arpInspectFilterAgingTime OBJECT-TYPE
        SYNTAX  INTEGER (0..2147483647)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { arpInspectSetup 2 }

    arpInspectLog  OBJECT IDENTIFIER ::= { arpInspectSetup 3 }

        arpInspectLogEntries OBJECT-TYPE
        SYNTAX  INTEGER    (0..1024)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { arpInspectLog 1 }

        arpInspectLogRate OBJECT-TYPE
        SYNTAX  INTEGER (0..1024)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { arpInspectLog 2 }

        arpInspectLogInterval OBJECT-TYPE
        SYNTAX  INTEGER (0..2147483647)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { arpInspectLog 3 }

    --arpInspectVlanTable
        arpInspectVlanTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF ArpInspectVlanEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { arpInspectSetup 4 }

    arpInspectVlanEntry OBJECT-TYPE
        SYNTAX    ArpInspectVlanEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        ""
        INDEX              { arpInspectVlanVid }
        ::= { arpInspectVlanTable 1 }

        ArpInspectVlanEntry ::=
           SEQUENCE {
            arpInspectVlanVid    INTEGER,
            arpInspectVlanLog    INTEGER,
            arpInspectVlanStatus    INTEGER
           }

        arpInspectVlanVid OBJECT-TYPE
        SYNTAX  INTEGER (1..4094)
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpInspectVlanEntry 1 }

        arpInspectVlanLog OBJECT-TYPE
        SYNTAX  INTEGER {
                all (1),
                none (2),
                permit (3),
                deny (4)
        }

        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpInspectVlanEntry 2 }

        arpInspectVlanStatus OBJECT-TYPE
        SYNTAX  INTEGER {
                enabled(1),
                disabled(2)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpInspectVlanEntry 3 }

    --arpInspectPortTable
        arpInspectPortTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF ArpInspectPortEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { arpInspectSetup 5 }

    arpInspectPortEntry OBJECT-TYPE
        SYNTAX    ArpInspectPortEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        ""
        INDEX              { arpInspectPortIndex }
        ::= { arpInspectPortTable 1 }

        ArpInspectPortEntry ::=
           SEQUENCE {
            arpInspectPortIndex    INTEGER,
            arpInspectPortTrust    INTEGER,
            arpInspectPortRate    INTEGER,
            arpInspectPortInterval    INTEGER
           }

        arpInspectPortIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpInspectPortEntry 1 }

        arpInspectPortTrust OBJECT-TYPE
        SYNTAX  INTEGER {
                trusted(1),
                untrusted(2)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpInspectPortEntry 2 }

        arpInspectPortRate OBJECT-TYPE
        SYNTAX  INTEGER    (0..2048)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpInspectPortEntry 3 }

        arpInspectPortInterval OBJECT-TYPE
        SYNTAX  INTEGER    (1..15)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpInspectPortEntry 4 }

    arpInspectStatus  OBJECT IDENTIFIER ::= { arpInspect 2 }

        arpInspectFilterClear OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { arpInspectStatus 1 }

        arpInspectLogClear OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { arpInspectStatus 2 }

    --arpInspectFilterTable
        arpInspectFilterTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF ArpInspectFilterEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { arpInspectStatus 3 }

    arpInspectFilterEntry OBJECT-TYPE
        SYNTAX    ArpInspectFilterEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        ""
        INDEX              { arpInspectFilterMac, arpInspectFilterVid }
        ::= { arpInspectFilterTable 1 }

        ArpInspectFilterEntry ::=
           SEQUENCE {
            arpInspectFilterMac    MacAddress,
            arpInspectFilterVid    INTEGER,
            arpInspectFilterPort    INTEGER,
            arpInspectFilterExpiry    INTEGER,
            arpInspectFilterReason    INTEGER,
            arpInspectFilterRowStatus RowStatus
           }

        arpInspectFilterMac OBJECT-TYPE
        SYNTAX  MacAddress
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpInspectFilterEntry 1 }

        arpInspectFilterVid OBJECT-TYPE
        SYNTAX  INTEGER (1..4094)
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpInspectFilterEntry 2 }

        arpInspectFilterPort OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpInspectFilterEntry 3 }

        arpInspectFilterExpiry OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpInspectFilterEntry 4 }

        arpInspectFilterReason OBJECT-TYPE
        SYNTAX  INTEGER {
                macVid(1),
                port(2),
                ip(3)
        }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpInspectFilterEntry 5 }

       arpInspectFilterRowStatus OBJECT-TYPE
        SYNTAX  RowStatus
        ACCESS  read-create
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpInspectFilterEntry 6 }

    --arpInspectLogTable
        arpInspectLogTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF ArpInspectLogEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { arpInspectStatus 4 }

    arpInspectLogEntry OBJECT-TYPE
        SYNTAX    ArpInspectLogEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        ""
        INDEX              { arpInspectLogMac, arpInspectLogVid, arpInspectLogPort, arpInspectLogIp, arpInspectLogReason }
        ::= { arpInspectLogTable 1 }

        ArpInspectLogEntry ::=
           SEQUENCE {
            arpInspectLogMac    MacAddress,
            arpInspectLogVid    INTEGER,
            arpInspectLogPort    INTEGER,
            arpInspectLogIp    IpAddress,
            arpInspectLogNumPkt    INTEGER,
            arpInspectLogReason    INTEGER,
            arpInspectLogTime    DateAndTime
           }

        arpInspectLogMac OBJECT-TYPE
        SYNTAX  MacAddress
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpInspectLogEntry 1 }

        arpInspectLogVid OBJECT-TYPE
        SYNTAX  INTEGER (1..4094)
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpInspectLogEntry 2 }

        arpInspectLogPort OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpInspectLogEntry 3 }

        arpInspectLogIp OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpInspectLogEntry 4 }

        arpInspectLogNumPkt OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpInspectLogEntry 5 }

        arpInspectLogReason OBJECT-TYPE
        SYNTAX  INTEGER {
                deny (1),
                denyStatic (2),
                denyDHCP (3),
                permitStatic (4),
                permitDHCP (5)
        }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpInspectLogEntry 6 }

        arpInspectLogTime OBJECT-TYPE
        SYNTAX  DateAndTime
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpInspectLogEntry 7 }

    --arpInspectStatisticsTable
        arpInspectStatisticsTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF ArpInspectStatisticsEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { arpInspectStatus 5 }

    arpInspectStatisticsEntry OBJECT-TYPE
        SYNTAX    ArpInspectStatisticsEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        ""
        INDEX              { arpInspectStatisticsVid }
        ::= { arpInspectStatisticsTable 1 }

        ArpInspectStatisticsEntry ::=
           SEQUENCE {
            arpInspectStatisticsVid    INTEGER,
            arpInspectStatisticsReceived    Counter,
            arpInspectStatisticsRequest    Counter,
            arpInspectStatisticsReply    Counter,
            arpInspectStatisticsForward    Counter,
            arpInspectStatisticsDrop    Counter,
            arpInspectStatisticsClear    EnabledStatus
           }

        arpInspectStatisticsVid OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpInspectStatisticsEntry 1 }

        arpInspectStatisticsReceived OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpInspectStatisticsEntry 2 }

        arpInspectStatisticsRequest OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpInspectStatisticsEntry 3 }

        arpInspectStatisticsReply OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpInspectStatisticsEntry 4 }

        arpInspectStatisticsForward OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpInspectStatisticsEntry 5 }

        arpInspectStatisticsDrop OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpInspectStatisticsEntry 6 }

        arpInspectStatisticsClear OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { arpInspectStatisticsEntry 7 }


-- trTCMSetup
    trTCMSetup OBJECT IDENTIFIER ::= { mgs370012c 103 }

        trTCMState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Two-rate three color marker enabled/disabled for the switch."
        ::= { trTCMSetup 1 }

        trTCMMode OBJECT-TYPE
        SYNTAX  INTEGER {
            color-aware(0),
            color-blind(1)
            }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { trTCMSetup 2 }

-- trTCMPortTable
        trTCMPortTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF TrTCMPortEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { trTCMSetup 3 }

    trTCMPortEntry OBJECT-TYPE
        SYNTAX    TrTCMPortEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in trTCMPortTable."
        INDEX              { dot1dBasePort }
        ::= { trTCMPortTable 1 }

        TrTCMPortEntry ::=
           SEQUENCE {
           trTCMPortState    EnabledStatus,
            trTCMPortCIR    INTEGER,
            trTCMPortPIR    INTEGER,
            trTCMPortDscpGreen    INTEGER,
            trTCMPortDscpYellow    INTEGER,
            trTCMPortDscpRed    INTEGER,
            trTCMPortCBS    INTEGER,
            trTCMPortPBS    INTEGER
           }

        trTCMPortState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-create
        STATUS  mandatory
        DESCRIPTION
                          "Two-rate three color marker enabled/disabled on the port."
        ::= { trTCMPortEntry 1 }

        trTCMPortCIR OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Allowed CIR in pkts/s."
        ::= { trTCMPortEntry 2 }

        trTCMPortPIR OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Allowed PIR in pkts/s."
        ::= { trTCMPortEntry 3 }

        trTCMPortDscpGreen OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "0-63"
        ::= { trTCMPortEntry 4 }

        trTCMPortDscpYellow OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "0-63"
        ::= { trTCMPortEntry 5 }

        trTCMPortDscpRed OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "0-63"
        ::= { trTCMPortEntry 6 }

        trTCMPortCBS OBJECT-TYPE
        SYNTAX  INTEGER(0..128000)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Commit burst size in Kbits.  The range is between 0 and 128,000."
        ::= { trTCMPortEntry 7}

        trTCMPortPBS OBJECT-TYPE
        SYNTAX  INTEGER(0..128000)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Peat burst size in Kbits.  The range is between 0 and 128,000."
        ::= { trTCMPortEntry 8 }


-- loopGuardSetup
    loopGuardSetup         OBJECT IDENTIFIER ::= { mgs370012c 104 }

        loopGuardState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { loopGuardSetup 1 }


-- loopGuardPortTable

        loopGuardPortTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF LoopGuardPortEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { loopGuardSetup 2 }

    loopGuardPortEntry OBJECT-TYPE
        SYNTAX    LoopGuardPortEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in loopGuardPortTable."
        INDEX              { dot1dBasePort }
        ::= { loopGuardPortTable 1 }

        LoopGuardPortEntry ::=
           SEQUENCE {
            loopGuardPortState    EnabledStatus
           }

        loopGuardPortState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { loopGuardPortEntry 1 }


-- subnetBasedVlanSetup
    subnetBasedVlanSetup OBJECT IDENTIFIER ::= { mgs370012c 105 }

        subnetBasedVlanState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "subnet-based vlan feature enabled/disabled for the switch."
        ::= { subnetBasedVlanSetup 1 }

        dhcpVlanOverrideState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "dhcp vlan override enabled/disabled when subnet-based vlan is enabled."
        ::= { subnetBasedVlanSetup 2 }


        subnetBasedVlanTable  OBJECT-TYPE
        SYNTAX    SEQUENCE OF SubnetBasedVlanEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { subnetBasedVlanSetup 3 }

        subnetBasedVlanEntry  OBJECT-TYPE
        SYNTAX    SubnetBasedVlanEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in subnetBasedVlanTable."
        INDEX              {subnetBasedVlanSrcIp , subnetBasedVlanSrcMaskBit}
        ::= { subnetBasedVlanTable 1 }

        SubnetBasedVlanEntry ::=
           SEQUENCE {
            subnetBasedVlanSrcIp            IpAddress,
            subnetBasedVlanSrcMaskBit        INTEGER,
            subnetBasedVlanName                DisplayString,
            subnetBasedVlanVid                INTEGER,
            subnetBasedVlanPriority            INTEGER,
            subnetBasedVlanEntryState        RowStatus
           }

        subnetBasedVlanSrcIp OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                          "source ip for subnet-based vlan entry"
        ::= { subnetBasedVlanEntry 1 }


        subnetBasedVlanSrcMaskBit OBJECT-TYPE
        SYNTAX  INTEGER (1..32)
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                          "source ip mask-bits for subnet-based vlan entry"
        ::= { subnetBasedVlanEntry 2 }

        subnetBasedVlanName OBJECT-TYPE
        SYNTAX  DisplayString (SIZE (0..32))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "name for subnet-based vlan entry"
        ::= { subnetBasedVlanEntry 3 }

        subnetBasedVlanVid OBJECT-TYPE
        SYNTAX  INTEGER (1..4094)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "vid for subnet-based vlan entry"
        ::= { subnetBasedVlanEntry 4 }


        subnetBasedVlanPriority OBJECT-TYPE
        SYNTAX  INTEGER (0..7)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "priority for subnet-based vlan entry"
        ::= { subnetBasedVlanEntry 5 }

        subnetBasedVlanEntryState OBJECT-TYPE
        SYNTAX  RowStatus
        ACCESS  read-create
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { subnetBasedVlanEntry 6 }


--  MAC Authentication
                 macAuthenticationSetup      OBJECT IDENTIFIER ::= { mgs370012c 106 }

        macAuthenticationState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                       ""
        ::= { macAuthenticationSetup 1 }

        macAuthenticationNamePrefix OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                       ""
        ::= { macAuthenticationSetup 2 }

        macAuthenticationPassword OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                       ""
        ::= { macAuthenticationSetup 3 }

        macAuthenticationTimeout OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                       ""
        ::= { macAuthenticationSetup 4 }

-- macAuthenticationPortTable

    macAuthenticationPortTable OBJECT-TYPE
        SYNTAX SEQUENCE OF MacAuthenticationPortEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                  ""
        ::= { macAuthenticationSetup 5 }

     macAuthenticationPortEntry OBJECT-TYPE
        SYNTAX MacAuthenticationPortEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION     "An entry in macAuthenticationPortTable."
        INDEX           { dot1dBasePort }
        ::= { macAuthenticationPortTable 1 }

        MacAuthenticationPortEntry ::=
        SEQUENCE {
            macAuthenticationPortState EnabledStatus
        }

        macAuthenticationPortState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                       ""
        ::= { macAuthenticationPortEntry 1 }

-- MSTP


        mstp            OBJECT IDENTIFIER ::= { mgs370012c 107 }
-- mstpGen group reflects configurations/statuses
-- the Bridge as a unit
        mstpGen            OBJECT IDENTIFIER ::= { mstp 1}

        mstpGenState        OBJECT-TYPE
        SYNTAX    EnabledStatus
        ACCESS    read-write
        STATUS    mandatory
        DESCRIPTION
        "Enabled/disabled on the mrstp bridge."
        ::= { mstpGen 1 }

        mstpGenCfgIdName    OBJECT-TYPE
        SYNTAX    DisplayString
        ACCESS    read-write
        STATUS    mandatory
        DESCRIPTION
        "The configuration name that identifies the MST
         region and is used as one of the inputs in the
         computation of the MST Configuration Identifier."
        REFERENCE
            "12.12.3.4.2.b)"
        ::= { mstpGen 2 }

        mstpGenCfgIdRevLevel OBJECT-TYPE
        SYNTAX    Integer32
        ACCESS    read-write
        STATUS    mandatory
        DESCRIPTION
        "This object identifies the MST revision that
         identifies the MST region and is used as one
         of the inputs in the computation of the MST
         configuration Identifier."
        REFERENCE
            "12.12.3.4.2.c)"
        ::= { mstpGen 3 }


       mstpGenCfgIdCfgDigest  OBJECT-TYPE
            SYNTAX    OCTET STRING(SIZE(16))
            ACCESS    read-only
            STATUS    mandatory
            DESCRIPTION
              "Configuration Digest."
            REFERENCE
               "12.12.3.3.3.a.4"
            ::= { mstpGen 4 }

        mstpGenHelloTime  OBJECT-TYPE
            SYNTAX    Timeout (1..10)
            ACCESS    read-write
            STATUS    mandatory
            DESCRIPTION
            ""
            ::= { mstpGen 5 }

        mstpGenMaxAge    OBJECT-TYPE
            SYNTAX  Timeout (6..40)
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
            ""
            ::= { mstpGen 6 }

        mstpGenForwardDelay   OBJECT-TYPE
            SYNTAX  Timeout (4..30)
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
            ""
            ::= {mstpGen 7}

        mstpGenMaxHops  OBJECT-TYPE
            SYNTAX      Integer32 (1..255)
            MAX-ACCESS  read-write
            STATUS      mandatory
            DESCRIPTION
               "13.22.f)"
            ::= { mstpGen 8 }

    mstpGenCistRootPathCost  OBJECT-TYPE
            SYNTAX      Integer32
            MAX-ACCESS  read-only
            STATUS      mandatory
            DESCRIPTION
        "."
            ::= { mstpGen 9 }

    mstpGenCistRootBrid  OBJECT-TYPE
            SYNTAX      OCTET STRING(SIZE(8))
            MAX-ACCESS  read-only
            STATUS      mandatory
            DESCRIPTION
            "."
            ::= { mstpGen 10 }
-- MSTP MAP TABLE
        mstMapTable        OBJECT-TYPE
            SYNTAX      SEQUENCE OF MstMapEntry
            ACCESS  not-accessible
            STATUS      mandatory
            DESCRIPTION
               "This table contains one entry for each instance of MSTP."
            ::= { mstp 20 }

        mstMapEntry        OBJECT-TYPE
            SYNTAX      MstMapEntry
            ACCESS  not-accessible
            STATUS      mandatory
            DESCRIPTION
               "A conceptual row containing the status of the MSTP instance."
            INDEX  { mstMapIndex }
            ::= { mstMapTable 1 }

        MstMapEntry ::= SEQUENCE {
                   mstMapIndex             MstiOrCistInstanceIndex,
                   mstMapVlans1k           OCTET STRING,
                   mstMapVlans2k           OCTET STRING,
                   mstMapVlans3k           OCTET STRING,
                   mstMapVlans4k           OCTET STRING,
                   mstMapRowStatus         RowStatus
        }

        mstMapIndex    OBJECT-TYPE
            SYNTAX      MstiOrCistInstanceIndex
            MAX-ACCESS  not-accessible
            STATUS      mandatory
            DESCRIPTION
            "Uniquely identifies an instance. The entry of this table with index 0
            presents always, represents CIST. When SET operation "
            ::= { mstMapEntry 1 }

        mstMapVlans1k      OBJECT-TYPE
            SYNTAX      OCTET STRING (SIZE (0..128))
            ACCESS  read-write
            STATUS      mandatory
            DESCRIPTION
           "A string of octets containing one bit per VLAN. The
            first octet corresponds to VLANs with VlanIndex values
            1 through 8; the second octet to VLANs 9 through
            16 etc.  The most significant bit of each octet
            corresponds to the lowest VlanIndex value in that octet.

            For each VLAN that is mapped to this MSTP instance,
            the bit corresponding to that VLAN is set to '1'.
            Empty (zero) most significant octes are not mandatory."
            ::= { mstMapEntry 2 }

        mstMapVlans2k      OBJECT-TYPE
            SYNTAX  OCTET STRING (SIZE (0..128))
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
            "A string of octets containing one bit per VLAN for
             VLANS with VlanIndex values 1024 through 2047. The
             first octet corresponds to VLANs with VlanIndex values
             1024 through 1031; the second octet to VLANs 1032
             through 1039 etc.  The most significant bit of each
             octet corresponds to the lowest VlanIndex value in that
             octet.

             For each VLAN that is mapped to this MSTP instance,
             the bit corresponding to that VLAN is set to '1'.

             Empty (zero) most significant octes are not mandatory."
             ::= { mstMapEntry 3 }

        mstMapVlans3k      OBJECT-TYPE
            SYNTAX      OCTET STRING (SIZE (0..128))
            ACCESS  read-write
            STATUS      current
            DESCRIPTION
            "A string of octets containing one bit per VLAN for
             VLANS with VlanIndex values 2048 through 3071. The
             first octet corresponds to VLANs with VlanIndex values
             of 2048 through 2055; the second octet to VLANs 2056
             through 2063 etc.  The most significant bit of each
             octet corresponds to the lowest VlanIndex value in that
             octet.

             For each VLAN that is mapped to this MSTP instance,
             the bit corresponding to that VLAN is set to '1'.

             Empty (zero) most significant octes are not mandatory."
             ::= { mstMapEntry 4 }

        mstMapVlans4k      OBJECT-TYPE
            SYNTAX      OCTET STRING (SIZE (0..128))
            MAX-ACCESS  read-write
            STATUS      current
            DESCRIPTION
            "A string of octets containing one bit per VLAN for
             VLANS with VlanIndex values 3072 through 4095. The
             first octet corresponds to VLANs with VlanIndex values
             3072 through 3079; the second octet to VLANs 3080
             through 3087 etc.  The most significant bit of each
             octet corresponds to the lowest VlanIndex value in that
             octet.

             For each VLAN that is mapped to this MSTP instance,
             the bit corresponding to that VLAN is set to '1'.

             Empty (zero) most significant octes are not mandatory."
             ::= { mstMapEntry 5 }

        mstMapRowStatus    OBJECT-TYPE
            SYNTAX  RowStatus
            ACCESS  read-create
            STATUS  mandatory
            DESCRIPTION
            ""
        ::= {  mstMapEntry 6 }

-- MSTP Vlan Table, map vlan to msti
        mstVlanTable       OBJECT-TYPE
            SYNTAX      SEQUENCE OF MstVlanEntry
            ACCESS  not-accessible
            STATUS      mandatory
            DESCRIPTION
            "This table contains one entry for each VlanId."
            ::= { mstp 30 }

        mstVlanEntry  OBJECT-TYPE
            SYNTAX      MstVlanEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "Information regarding the instance to which each Vlan is mapped."
            INDEX  { mstVlanIndex }
            ::= { mstVlanTable 1 }

        MstVlanEntry ::= SEQUENCE {
              mstVlanIndex         INTEGER,
              mstVlanMstIndex      MstiOrCistInstanceIndex
        }


        mstVlanIndex     OBJECT-TYPE
            SYNTAX        INTEGER(1..4094)
            ACCESS        not-accessible
            STATUS        mandatory
            DESCRIPTION
                "The VlanId for which this entry contains the instance mapped."
            ::= { mstVlanEntry 1 }

        mstVlanMstIndex    OBJECT-TYPE
             SYNTAX      MstiOrCistInstanceIndex
             ACCESS  read-only
             STATUS      mandatory
             DESCRIPTION
                 "An integer with values ranging from 0 to 64 that identify a
                      the CIST/MSTI instance to which this VLAN is mapped"
             ::= { mstVlanEntry 2 }
-- MSTP Port Table, information for all instance of a port
        mstpPortTable      OBJECT-TYPE
            SYNTAX      SEQUENCE OF MstpPortEntry
            ACCESS  not-accessible
            STATUS      mandatory
            DESCRIPTION
                "A table that contains generic information about
                every port that is associated with this bridge."
            ::= { mstp 40 }

        mstpPortEntry      OBJECT-TYPE
            SYNTAX  MstpPortEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
            "A list of information for each port of the
            bridge."
            INDEX  { mstpPortIndex }
            ::= { mstpPortTable 1 }

        MstpPortEntry ::= SEQUENCE {
             mstpPortIndex                    INTEGER,
             mstpPortOperEdgePort             TruthValue,
             mstpPortOperPointToPointMAC      TruthValue
        }

        mstpPortIndex    OBJECT-TYPE
            SYNTAX    INTEGER (1..65535)
            ACCESS  not-accessible
            STATUS      mandatory
            DESCRIPTION
            "A unique value, greater than zero, for each Port.
            The value for each interface sub-layer
            must remain constant at least from one re-initialization
            of the entity's network management system to the next re-
            initialization."
            ::= { mstpPortEntry 1 }

        mstpPortOperEdgePort    OBJECT-TYPE
            SYNTAX    TruthValue
            ACCESS    read-only
            STATUS    mandatory
            DESCRIPTION
            ""
            REFERENCE   ""
            ::= { mstpPortEntry 2 }

        mstpPortOperPointToPointMAC    OBJECT-TYPE
            SYNTAX    TruthValue
            ACCESS    read-only
            STATUS    mandatory
            DESCRIPTION
            ""
            REFERENCE    ""
            ::= {mstpPortEntry 3}
-- MSTP Xst Table, Cist/Mst status/setting
        mstpXstTable  OBJECT-TYPE
              SYNTAX      SEQUENCE OF MstpXstEntry
              ACCESS  not-accessible
              STATUS      mandatory
              DESCRIPTION
                "."
              ::= { mstp 50 }

        mstpXstEntry OBJECT-TYPE
              SYNTAX      MstpXstEntry
              ACCESS  not-accessible
              STATUS      mandatory
              DESCRIPTION
                "."
              INDEX { mstpXstId }
              ::= { mstpXstTable 1 }

       MstpXstEntry ::= SEQUENCE {
               mstpXstId                      MstiOrCistInstanceIndex,
               mstpXstBridgePriority          Integer32,
               mstpXstBridgeId                BridgeId,
               mstpXstInternalRootCost        Integer32,
               mstpXstRootPort                INTEGER,
               mstpXstTimeSinceTopologyChange TimeTicks,
               mstpXstTopologyChangesCount    Counter32
       }

       mstpXstId   OBJECT-TYPE
           SYNTAX      MstiOrCistInstanceIndex
           ACCESS      read-only
           STATUS      mandatory
           DESCRIPTION
             "0 means CIST."
           ::= { mstpXstEntry 1 }

       mstpXstBridgePriority   OBJECT-TYPE
           SYNTAX      Integer32 (0..61440)
           ACCESS  read-write
           STATUS      mandatory
           DESCRIPTION
              "Bridge priority, in steps of 4096."
           DEFVAL       { 32768 }
           ::= { mstpXstEntry 2 }

       mstpXstBridgeId   OBJECT-TYPE
           SYNTAX      BridgeId
           ACCESS      read-only
           STATUS      mandatory
           DESCRIPTION
             "."
           ::= { mstpXstEntry 3 }


       mstpXstInternalRootCost     OBJECT-TYPE
           SYNTAX      Integer32
           ACCESS      read-only
           STATUS      mandatory
           DESCRIPTION
             "."
           ::= { mstpXstEntry 4 }

       mstpXstRootPort      OBJECT-TYPE
           SYNTAX      INTEGER
           ACCESS      read-only
           STATUS      mandatory
           DESCRIPTION
           "."
           ::= { mstpXstEntry 5 }

       mstpXstTimeSinceTopologyChange  OBJECT-TYPE
           SYNTAX      TimeTicks
           ACCESS      read-only
           STATUS      mandatory
           DESCRIPTION
             "."
           ::= { mstpXstEntry 6 }

       mstpXstTopologyChangesCount     OBJECT-TYPE
           SYNTAX      Counter32
           ACCESS      read-only
           STATUS      mandatory
           DESCRIPTION
             "."
           ::= { mstpXstEntry 7 }
-- MSTP Xst Port Table, Cist/Mst Port status/setting
       mstpXstPortTable    OBJECT-TYPE
           SYNTAX  SEQUENCE OF MstpXstPortEntry
           ACCESS  not-accessible
           STATUS  mandatory
           DESCRIPTION
             "."
           ::= { mstp 60 }

       mstpXstPortEntry    OBJECT-TYPE
           SYNTAX  MstpXstPortEntry
           ACCESS  not-accessible
           STATUS  mandatory
           DESCRIPTION
             "."
           REFERENCE
             "."
           INDEX  { mstpXstPortXstId, mstpXstPortIndex }
           ::= { mstpXstPortTable 1 }


        MstpXstPortEntry ::=
        SEQUENCE {
             mstpXstPortXstId                 MstiOrCistInstanceIndex,
              mstpXstPortIndex                 INTEGER,
              mstpXstPortEnable                EnabledStatus,
              mstpXstPortPriority              Integer32,
              mstpXstPortPathCost              INTEGER,
              mstpXstPortState                 INTEGER,
              mstpXstPortDesignatedRoot        BridgeId,
              mstpXstPortDesignatedCost        Integer32,
              mstpXstPortDesignatedBridge      BridgeId,
              mstpXstPortDesignatedPort        INTEGER
        }

        mstpXstPortXstId     OBJECT-TYPE
            SYNTAX      MstiOrCistInstanceIndex
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
              "0 means CIST."
            ::= { mstpXstPortEntry 1 }

        mstpXstPortIndex     OBJECT-TYPE
            SYNTAX      INTEGER(1..65535)
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
              "The value of mstpPortIndex of the Port
              in mstpPortTable."
            ::= { mstpXstPortEntry 2 }


        mstpXstPortEnable     OBJECT-TYPE
            SYNTAX      EnabledStatus
            ACCESS      read-write
            STATUS      mandatory
            DESCRIPTION
              "."
            ::= { mstpXstPortEntry 3 }

         mstpXstPortPriority              OBJECT-TYPE
             SYNTAX      Integer32 (0..255)
             ACCESS      read-write
             STATUS      mandatory
             DESCRIPTION
               "Port priority, in steps of 16."
             DEFVAL       { 128 }
             ::= { mstpXstPortEntry 4 }

         mstpXstPortPathCost              OBJECT-TYPE
             SYNTAX      INTEGER (1..65535)
             ACCESS      read-write
             STATUS      mandatory
             DESCRIPTION
               "."
             ::= { mstpXstPortEntry 5 }

         mstpXstPortState                 OBJECT-TYPE
             SYNTAX      INTEGER {
               disabled(0),
               discarding(1),
               learning(2),
               forwarding(3),
               unknown(4)
             }
             ACCESS      read-only
             STATUS      mandatory
             DESCRIPTION
               "."
             ::= { mstpXstPortEntry 6 }

         mstpXstPortDesignatedRoot        OBJECT-TYPE
              SYNTAX      BridgeId
              ACCESS      read-only
              STATUS      mandatory
              DESCRIPTION
              "."
              ::= { mstpXstPortEntry 7 }

         mstpXstPortDesignatedCost        OBJECT-TYPE
             SYNTAX      Integer32
             ACCESS      read-only
             STATUS      mandatory
             DESCRIPTION
             "."
             ::= { mstpXstPortEntry 8 }

         mstpXstPortDesignatedBridge      OBJECT-TYPE
             SYNTAX      BridgeId
             ACCESS      read-only
             STATUS      mandatory
             DESCRIPTION
             "."
             ::= { mstpXstPortEntry 9 }

         mstpXstPortDesignatedPort      OBJECT-TYPE
             SYNTAX      INTEGER
             ACCESS      read-only
             STATUS      mandatory
             DESCRIPTION
             "."
             ::= { mstpXstPortEntry 10 }
--MSTP Traps
          mstpNotifications         OBJECT IDENTIFIER ::= { mstp 70 }

         newRoot NOTIFICATION-TYPE
         OBJECTS {
                mstpXstId
         }
         STATUS  current
         DESCRIPTION
          ""
         ::= { mstpNotifications 1 }

         topologyChange NOTIFICATION-TYPE
         OBJECTS {
                mstpXstId
         }
         STATUS  current
         DESCRIPTION
          ""
         ::= { mstpNotifications 2 }


---------------------------------------------------
--
--  Port Isolation
--
---------------------------------------------------

-- portIsolationTable
    portIsolationSetup OBJECT IDENTIFIER ::= { mgs370012c 112 }

        portIsolationTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF PortIsolationEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { portIsolationSetup 1 }

    portIsolationEntry OBJECT-TYPE
        SYNTAX    PortIsolationEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in portIsolationTable."
        INDEX              { dot1dBasePort }
        ::= { portIsolationTable 1 }

        PortIsolationEntry ::=
           SEQUENCE {
            portIsolationState        EnabledStatus
           }

        portIsolationState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Port isolation enabled/disabled on the port.
                          Enable(1) to be isolated and not exchange packets."
        ::= { portIsolationEntry 1 }


---------------------------------------------------
--
--  Layer 2 Protocol Tunneling
--
---------------------------------------------------
 l2ptSetup      OBJECT IDENTIFIER ::= { mgs370012c 115 }

--  l2ptState
        l2ptState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                       "L2PT feature enabled/disabled for the switch"
        ::= { l2ptSetup 1 }

        l2ptMacAddr OBJECT-TYPE
        SYNTAX  MacAddress
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                       "L2PT destination mac address"
        ::= { l2ptSetup 2 }

-- l2ptTable

        l2ptTable OBJECT-TYPE
        SYNTAX SEQUENCE OF L2ptEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                  ""
        ::= { l2ptSetup 3 }

 l2ptEntry OBJECT-TYPE
        SYNTAX L2ptEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION     "An entry in l2ptTable."
        INDEX           { dot1dBasePort }
        ::= { l2ptTable 1 }

        L2ptEntry ::=
           SEQUENCE {
         l2ptProtocolGroup  BITS,
         l2ptPointToPointProtocolGroup BITS,
         l2ptMode   INTEGER
           }

     l2ptProtocolGroup OBJECT-TYPE
        SYNTAX BITS {
          cdpP(0),
          stp(1),
          vtp(2)
         }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                       "L2PT protocols enabled/disabled on the port"
        ::= { l2ptEntry 1 }

     l2ptPointToPointProtocolGroup OBJECT-TYPE
        SYNTAX BITS {
          pagp(0),
          lacp(1),
          udld(2)
         }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                       "L2PT point-to-point protocols enabled/disabled on the port"
        ::= { l2ptEntry 2 }

        l2ptMode OBJECT-TYPE
        SYNTAX  INTEGER {
         access(1),
         tunnel(2)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                       "L2PT port role on the port"
        ::= { l2ptEntry 3 }


---------------------------------------------------
--
--  vlan mapping
--
---------------------------------------------------

-- vlanMappingSetup
    vlanMappingSetup         OBJECT IDENTIFIER ::= { mgs370012c 116 }

        vlanMappingState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { vlanMappingSetup 1 }


-- vlanMappingPortTable

        vlanMappingPortTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF VlanMappingPortEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { vlanMappingSetup 2 }

    vlanMappingPortEntry OBJECT-TYPE
        SYNTAX    VlanMappingPortEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in vlanMappingPortTable."
        INDEX              { dot1dBasePort }
        ::= { vlanMappingPortTable 1 }

        VlanMappingPortEntry ::=
           SEQUENCE {
            vlanMappingPortState    EnabledStatus
           }

        vlanMappingPortState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { vlanMappingPortEntry 1 }

-- vlanMappingRuleTable
        vlanMappingRuleTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF VlanMappingRuleEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { vlanMappingSetup 3 }

    vlanMappingRuleEntry OBJECT-TYPE
        SYNTAX    VlanMappingRuleEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in vlan-mapping rule table"
        INDEX              { vlanMappingRulePort, vlanMappingRuleVid }
        ::= { vlanMappingRuleTable 1 }

        VlanMappingRuleEntry ::=
           SEQUENCE {
               vlanMappingRuleName        DisplayString,
            vlanMappingRulePort        INTEGER,
            vlanMappingRuleVid        INTEGER,
            vlanMappingRuleTransVid    INTEGER,
            vlanMappingRulePriority    INTEGER,
            vlanMappingRuleRowStatus    RowStatus
           }

        vlanMappingRuleName OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "The name of vlan-mapping entry"
        ::= { vlanMappingRuleEntry 1 }

        vlanMappingRulePort OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                         "interface port id"
        ::= { vlanMappingRuleEntry 2 }

        vlanMappingRuleVid OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                         "inner vid"
        ::= { vlanMappingRuleEntry 3 }

        vlanMappingRuleTransVid OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                         "translated vid"
        ::= { vlanMappingRuleEntry 4 }

        vlanMappingRulePriority OBJECT-TYPE
        SYNTAX  INTEGER {
                prioriry-0(0),
                prioriry-1(1),
                prioriry-2(2),
                prioriry-3(3),
                prioriry-4(4),
                prioriry-5(5),
                prioriry-6(6),
                prioriry-7(7)
        }

        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                         "priority"
        ::= { vlanMappingRuleEntry 5 }

        vlanMappingRuleRowStatus OBJECT-TYPE
        SYNTAX  RowStatus
        ACCESS  read-create
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { vlanMappingRuleEntry 6 }

-- transceiverInfoTable
        transceiverInfo OBJECT IDENTIFIER ::= { mgs370012c 117 }

-- transceiverSerialInfoTable

        transceiverSerialInfoTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF TransceiverSerialInfoEntry
        ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
                     ""
        ::= { transceiverInfo 1 }

        transceiverSerialInfoEntry OBJECT-TYPE
        SYNTAX    TransceiverSerialInfoEntry
        ACCESS    not-accessible
        STATUS    current
        DESCRIPTION        "An entry in transceiverSerialInfoTable."
        INDEX              { transceiverSerialInfoEntryPort }
        ::= { transceiverSerialInfoTable 1 }

        TransceiverSerialInfoEntry ::=
           SEQUENCE {
            transceiverSerialInfoEntryPort            INTEGER,
            transceiverSerialInfoEntryStatus        INTEGER,
            transceiverSerialInfoEntryVendor        DisplayString,
            transceiverSerialInfoEntryPartNo        DisplayString,
            transceiverSerialInfoEntrySerialNo        DisplayString,
            transceiverSerialInfoEntryRevision        DisplayString,
            transceiverSerialInfoEntryDateCode        DisplayString,
            transceiverSerialInfoEntryTransceiver    DisplayString
           }

        transceiverSerialInfoEntryPort OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "Index of transceiverSerialInfo. It is referred to dot1dBasePort"
        ::= { transceiverSerialInfoEntry 1 }

        transceiverSerialInfoEntryStatus OBJECT-TYPE
        SYNTAX  INTEGER {
                ok-with-DDM(1),
                ok-without-DDM(2),
                nonoperational(3)
        }
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "Transceiver module status."
        ::= { transceiverSerialInfoEntry 2 }


        transceiverSerialInfoEntryVendor OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "Transceiver module vendor name."
        ::= { transceiverSerialInfoEntry 3 }

        transceiverSerialInfoEntryPartNo OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "Part number provided by transceiver module vendor."
        ::= { transceiverSerialInfoEntry 4 }

        transceiverSerialInfoEntrySerialNo OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "Serial number provided by transceiver module vendor."
        ::= { transceiverSerialInfoEntry 5 }

        transceiverSerialInfoEntryRevision OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "Revision level for part number provided by transceiver module vendor."
        ::= { transceiverSerialInfoEntry 6 }

        transceiverSerialInfoEntryDateCode OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "Transceiver module vendor's manufacturing date code"
        ::= { transceiverSerialInfoEntry 7 }

        transceiverSerialInfoEntryTransceiver OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "Transceiver module type names"
        ::= { transceiverSerialInfoEntry 8 }

-- transceiverDdmInfoTable

        transceiverDdmInfoTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF TransceiverDdmInfoEntry
        ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
                     ""
        ::= { transceiverInfo 2 }

        transceiverDdmInfoEntry OBJECT-TYPE
        SYNTAX    TransceiverDdmInfoEntry
        ACCESS    not-accessible
        STATUS    current
        DESCRIPTION        "An entry in transceiverDdmInfoTable."
        INDEX              { transceiverDdmInfoEntryPort, transceiverDdmInfoEntryType }
        ::= { transceiverDdmInfoTable 1 }

        TransceiverDdmInfoEntry ::=
           SEQUENCE {
            transceiverDdmInfoEntryPort            INTEGER,
            transceiverDdmInfoEntryType            INTEGER,
            transceiverDdmInfoEntryAlarmMax        INTEGER,
            transceiverDdmInfoEntryAlarmMin        INTEGER,
            transceiverDdmInfoEntryWarnMax        INTEGER,
            transceiverDdmInfoEntryWarnMin        INTEGER,
            transceiverDdmInfoEntryCurrent        INTEGER,
            transceiverDdmInfoEntryDescription    DisplayString
           }

        transceiverDdmInfoEntryPort OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "Index of transceiverDdmInfo. This will be referred to dot1dBasePort"
        ::= { transceiverDdmInfoEntry 1 }

        transceiverDdmInfoEntryType OBJECT-TYPE
        SYNTAX  INTEGER {
                temperature(1),
                voltage(2),
                bias(3),
                txPower(4),
                rxPower(5)
        }
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "Transceiver DDM information type.
                          1: Temperature
                        2: Voltage
                        3: TX Bias
                        4: TX power
                        5: RX power"
        ::= { transceiverDdmInfoEntry 2 }


        transceiverDdmInfoEntryAlarmMax OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "Transceiver high alarm threshold.
                          The unit for temperature is 0.01C
                        The unit for voltage is 0.01V
                        The unit for TX bias is 0.01mA
                        The unit for TX/RX power is 0.01dbm"
        ::= { transceiverDdmInfoEntry 3 }

        transceiverDdmInfoEntryAlarmMin OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "Transceiver low alarm threshold.
                         The unit for temperature is 0.01C
                         The unit for voltage is 0.01V
                         The unit for TX bias is 0.01mA
                         The unit for TX/RX power is 0.01dbm"
        ::= { transceiverDdmInfoEntry 4 }

        transceiverDdmInfoEntryWarnMax OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "Transceiver high warn threshold.
                         The unit for temperature is 0.01C
                         The unit for voltage is 0.01V
                         The unit for TX bias is 0.01mA
                         The unit for TX/RX power is 0.01dbm"
        ::= { transceiverDdmInfoEntry 5 }

        transceiverDdmInfoEntryWarnMin OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "Transceiver low warn threshold.
                         The unit for temperature is 0.01C
                         The unit for voltage is 0.01V
                         The unit for TX bias is 0.01mA
                         The unit for TX/RX power is 0.01dbm"
        ::= { transceiverDdmInfoEntry 6 }

        transceiverDdmInfoEntryCurrent OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "Transceiver current DDM value.
                         The unit for temperature is 0.01C
                         The unit for voltage is 0.01V
                         The unit for TX bias is 0.01mA
                         The unit for TX/RX power is 0.01dbm"
        ::= { transceiverDdmInfoEntry 7 }

        transceiverDdmInfoEntryDescription OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  current
        DESCRIPTION
                          "Transceiver DDM information description. Show N/A if transceiver DDM information is not available."
        ::= { transceiverDdmInfoEntry 8 }


-- dot3OamSetup
    dot3OamSetup         OBJECT IDENTIFIER ::= { mgs370012c 118 }

        dot3OamState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { dot3OamSetup 1 }


-- dot3OamPortTable

        dot3OamPortTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF Dot3OamPortEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { dot3OamSetup 2 }

    dot3OamPortEntry OBJECT-TYPE
        SYNTAX    Dot3OamPortEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in dot3OamPortTable."
        INDEX              { ifIndex }
        ::= { dot3OamPortTable 1 }

        Dot3OamPortEntry ::=
           SEQUENCE {
           dot3OamFunctionsSupported          BITS
           }

        dot3OamFunctionsSupported OBJECT-TYPE
        SYNTAX      BITS {
                      unidirectionalSupport (0),
                      loopbackSupport(1),
                      eventSupport(2),
                      variableSupport(3)
                    }
        MAX-ACCESS  read-write
        STATUS    mandatory
        DESCRIPTION
          "The OAM functions supported on this Ethernet-like interface.
          OAM consists of separate functional sets beyond the basic
          discovery process that is always required.  These functional
          groups can be supported independently by any implementation.
          These values are communicated to the peer via the local
          configuration field of Information OAMPDUs.

          Setting 'unidirectionalSupport(0)' indicates that the OA
          entity supports the transmission of OAMPDUs on links that are
          operating in unidirectional mode (traffic flowing in one
          direction only).  Setting 'loopbackSupport(1)' indicates that
          the OAM entity can initiate and respond to loopback commands.
          Setting 'eventSupport(2)' indicates that the OAM entity can
          send and receive Event Notification OAMPDUs.  Setting
          'variableSupport(3)' indicates that the OAM entity can send
          and receive Variable Request and Response OAMPDUs.
          "
        REFERENCE   "[802.3ah], 30.3.6.1.6"
        ::= { dot3OamPortEntry 1 }

         --  dot1agCfmMib


    dot1agCfmSetup                    OBJECT IDENTIFIER ::= { mgs370012c 119 }

    dot1agCfmMIBObjects         OBJECT IDENTIFIER ::= { dot1agCfmSetup 1 }

    -- ******************************************************************
    -- Groups in the CFM MIB Module
    -- ******************************************************************
    zyswdot1agCfmManAddressDomain OBJECT-TYPE
        SYNTAX  TDomain
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "This object indicates the transport type of the address contained
            in Sender ID TLV.

            Typical values will be one of (not all inclusive) list:
                transportDomainUdpIpv4          (1.3.6.1.2.1.100.1.1)
                snmpIeee802Domain                 (1.3.6.1.6.1.6)
            "
        ::= { dot1agCfmMIBObjects 1 }

     zyswdot1agCfmManAddress OBJECT-TYPE
        SYNTAX  TAddress
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "The Address that can be used to manage the responding MP."
        ::= { dot1agCfmMIBObjects 2 }

    dot1agCfmMep             OBJECT IDENTIFIER ::= { dot1agCfmMIBObjects 7 }

    -- ******************************************************************
    -- The MEP Table
    -- ******************************************************************
    zyswdot1agCfmMepTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF Zyswdot1agCfmMepEntry
        MAX-ACCESS  not-accessible
        STATUS      mandatory
        DESCRIPTION
           ""
        ::= { dot1agCfmMep 1 }

    zyswdot1agCfmMepEntry OBJECT-TYPE
        SYNTAX      Zyswdot1agCfmMepEntry
        MAX-ACCESS  not-accessible
        STATUS      mandatory
        DESCRIPTION
           "The dot1agCfmMep table entry"
        INDEX { dot1agCfmMdIndex,
                dot1agCfmMaIndex,
                dot1agCfmMepIdentifier
              }
        ::= { zyswdot1agCfmMepTable 1 }

    Zyswdot1agCfmMepEntry ::= SEQUENCE {
          zyswdot1agCfmMepTransmitLbmDataTlvSize           Unsigned32
        }

    zyswdot1agCfmMepTransmitLbmDataTlvSize OBJECT-TYPE
        SYNTAX      Unsigned32 (0..1500)
        MAX-ACCESS  read-write
        STATUS      mandatory
        DESCRIPTION
           "Size of data to be included in the LBM Data TLV"
        REFERENCE
           ""
        ::= { zyswdot1agCfmMepEntry 1 }

    -- ******************************************************************
    -- Vlan counter mib
    -- ******************************************************************
    vlanCounterSetup                    OBJECT IDENTIFIER ::= { mgs370012c 122  }

    -- VlanCounter Table
    vlanCounterTable OBJECT-TYPE
               SYNTAX      SEQUENCE OF VlanCounterEntry
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                "Defines the Vlan Counter Table for providing, via SNMP,
        the capability of performing vlan counting operations at
        a remote host and having their results of these operations are
        stored in the table."

        ::= { vlanCounterSetup 1 }

    vlanCounterEntry OBJECT-TYPE
        SYNTAX      VlanCounterEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Defines an entry in the VlanCounterTable."
        INDEX {
                vlanCounterVlanID
        }
    ::= { vlanCounterTable 1 }

    VlanCounterEntry ::=
        SEQUENCE {
            vlanCounterVlanID                  Unsigned32,
            vlanCounterHCOctets                Counter64,
            vlanCounterHCPkts                  Counter64,
            vlanCounterHCMulticastPkts         Counter64,
            vlanCounterHCBroadcastPkts         Counter64,
            vlanCounterHCTaggedPkts            Counter64,
            vlanCounterHCPkts64Octets             Counter64,
            vlanCounterHCPkts65to127Octets     Counter64,
            vlanCounterHCPkts128to255Octets    Counter64,
            vlanCounterHCPkts256to511Octets    Counter64,
            vlanCounterHCPkts512to1023Octets   Counter64,
            vlanCounterHCPkts1024to1518Octets  Counter64,
            vlanCounterHCOversizePkts          Counter64,
            vlanCounterTimeout                 Unsigned32,
            vlanCounterRowStatus               RowStatus,
            vlanCounterPort                    PortList,
            vlanCounterHCUnicastPkts           Counter64
    }

    vlanCounterVlanID OBJECT-TYPE
        SYNTAX      Unsigned32 (1..4094)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
         " VlanID where the vlan counter applies."
    ::= { vlanCounterEntry 1 }

   vlanCounterHCOctets OBJECT-TYPE
        SYNTAX      Counter64
        UNITS       "Octets"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Average receive Octets"
        ::= { vlanCounterEntry 2 }

    vlanCounterHCPkts OBJECT-TYPE
        SYNTAX      Counter64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Total received packet number"
        ::= { vlanCounterEntry 3 }

    vlanCounterHCMulticastPkts OBJECT-TYPE
        SYNTAX      Counter64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Total received multicast-packet number"
        ::= { vlanCounterEntry 4 }

    vlanCounterHCBroadcastPkts OBJECT-TYPE
        SYNTAX      Counter64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
             "Total received Broadcast-packet number"
        ::= { vlanCounterEntry 5 }

    vlanCounterHCTaggedPkts OBJECT-TYPE
        SYNTAX      Counter64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
             "Total received tagged-packet number"
        ::= { vlanCounterEntry 6 }

    vlanCounterHCPkts64Octets OBJECT-TYPE
        SYNTAX      Counter64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Total received packet number in size of 0 to 64 Octets"
        ::= { vlanCounterEntry 7 }

    vlanCounterHCPkts65to127Octets OBJECT-TYPE
        SYNTAX      Counter64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Total received packet number in size of 65 to127 Octets"
        ::= { vlanCounterEntry 8 }

    vlanCounterHCPkts128to255Octets OBJECT-TYPE
        SYNTAX      Counter64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Total received packet number in size of 128 to 255Octets"
        ::= { vlanCounterEntry 9 }

    vlanCounterHCPkts256to511Octets  OBJECT-TYPE
        SYNTAX      Counter64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Total received packet number in size of 256 to 511 Octets"
        ::= { vlanCounterEntry 10 }

    vlanCounterHCPkts512to1023Octets OBJECT-TYPE
        SYNTAX      Counter64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Total received packet number in size of 512 to 1023 Octets"
        ::= { vlanCounterEntry 11 }

    vlanCounterHCPkts1024to1518Octets OBJECT-TYPE
        SYNTAX      Counter64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Total received packet number in size of 1024 to 1518 Octets"
        ::= { vlanCounterEntry 12 }

    vlanCounterHCOversizePkts OBJECT-TYPE
        SYNTAX     Counter64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Total received packet number in size larger than 1519 Octets"
        ::= { vlanCounterEntry 13 }

    vlanCounterTimeout OBJECT-TYPE
        SYNTAX  Unsigned32
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Specifies the time-out value, in seconds, for a vlan counter operation."
        ::= { vlanCounterEntry 14 }

    vlanCounterRowStatus OBJECT-TYPE
        SYNTAX      RowStatus
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
         "Specifies the time-out value, in seconds, for a vlan counter operation."

        ::= { vlanCounterEntry 15 }

    vlanCounterPort OBJECT-TYPE
        SYNTAX        PortList
        MAX-ACCESS    read-write
        STATUS        current
        DESCRIPTION
            "Port where the vlan counter applies. (Only support one or all bit setting now)"
        ::= { vlanCounterEntry 16 }

    vlanCounterHCUnicastPkts OBJECT-TYPE
        SYNTAX      Counter64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Total received unicast-packet number"
        ::= { vlanCounterEntry 17 }

-- ******************************************************************
-- *
-- * sFlow mib
-- *
-- ******************************************************************
    sFlowSetup         OBJECT IDENTIFIER ::= { mgs370012c 123 }

    sFlowState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
        "Sflow enabled/disabled for the switch."
        ::= { sFlowSetup 1 }
-- *
-- * sFlow Collector Table
-- *
    sFlowCollectorTable OBJECT-TYPE
               SYNTAX      SEQUENCE OF SFlowCollectorEntry
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                ""
              ::= { sFlowSetup 2 }

    sFlowCollectorEntry OBJECT-TYPE
        SYNTAX      SFlowCollectorEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "An entry in sflowCollectorTable."
        INDEX {
            sFlowCollectorAddressType,
            sFlowCollectorAddress
        }
    ::= { sFlowCollectorTable 1 }

    SFlowCollectorEntry ::=
        SEQUENCE {
            sFlowCollectorAddressType    InetAddressType,
            sFlowCollectorAddress        InetAddress,
            sFlowCollectorUdpPort        Unsigned32,
            sFlowCollectorRowStatus      RowStatus
        }

    sFlowCollectorAddressType OBJECT-TYPE
        SYNTAX      InetAddressType
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
         " The Type of IP address for sflow collector entry."
    ::= { sFlowCollectorEntry 1 }

    sFlowCollectorAddress OBJECT-TYPE
        SYNTAX      InetAddress
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
         "The IP address for sflow collector entry."
    ::= { sFlowCollectorEntry 2 }

    sFlowCollectorUdpPort OBJECT-TYPE
        SYNTAX      Unsigned32 (1..65535)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
         "The UDP port for sflow collector entry. The range of UDP port is between 1 and 65535."
    ::= { sFlowCollectorEntry 3 }

    sFlowCollectorRowStatus OBJECT-TYPE
        SYNTAX      RowStatus
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
         ""
        ::= { sFlowCollectorEntry 4 }



-- *
-- * sFlow Port Table
-- *
    sFlowPortTable OBJECT-TYPE
               SYNTAX      SEQUENCE OF SFlowPortEntry
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                ""
              ::= { sFlowSetup 3 }

    sFlowPortEntry OBJECT-TYPE
        SYNTAX      SFlowPortEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "An entry in sflowPortTable."
        INDEX {
            dot1dBasePort
        }
    ::= { sFlowPortTable 1 }

    SFlowPortEntry ::=
        SEQUENCE {
           sFlowPortState    EnabledStatus
         }

    sFlowPortState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
        "Sflow enabled/disabled on the port."
        ::= { sFlowPortEntry 1 }

-- *
-- * sFlow Port Collector Table
-- *
    sFlowPortCollectorTable OBJECT-TYPE
               SYNTAX      SEQUENCE OF SFlowPortCollectorEntry
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
              ""
              ::= { sFlowSetup 4 }

    sFlowPortCollectorEntry OBJECT-TYPE
        SYNTAX      SFlowPortCollectorEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "An entry in sflowCollectorTable."
        INDEX {
            dot1dBasePort,
            sFlowPortCollectorAddressType,
            sFlowPortCollectorAddress
        }
    ::= { sFlowPortCollectorTable 1 }

    SFlowPortCollectorEntry ::=
        SEQUENCE {
            sFlowPortCollectorAddressType    InetAddressType,
            sFlowPortCollectorAddress        InetAddress,
            sFlowPortCollectorSampleRate     Unsigned32,
            sFlowPortCollectorPollInterval   Unsigned32,
            sFlowPortCollectorRowStatus      RowStatus
        }

    sFlowPortCollectorAddressType OBJECT-TYPE
        SYNTAX      InetAddressType
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
         " The Type of IP address for sflow port collector entry."
    ::= { sFlowPortCollectorEntry 1 }

    sFlowPortCollectorAddress OBJECT-TYPE
        SYNTAX      InetAddress
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
         "The IP address for sflow port collector entry."
    ::= { sFlowPortCollectorEntry 2 }

    sFlowPortCollectorSampleRate OBJECT-TYPE
        SYNTAX      Unsigned32 (256..65535)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
         "The sample rate. The range of samle rate is beteen 256 and 65535."
    ::= { sFlowPortCollectorEntry 3 }

    sFlowPortCollectorPollInterval OBJECT-TYPE
        SYNTAX      Unsigned32 (20..120)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
         "The poll interval. The range of poll interval is between 20 and 120."
    ::= { sFlowPortCollectorEntry 4 }

    sFlowPortCollectorRowStatus OBJECT-TYPE
        SYNTAX      RowStatus
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
         ""
    ::= { sFlowPortCollectorEntry 5 }

-- ******************************************************************
-- *
-- * memory usage MIB
-- *
-- ******************************************************************
    sysMemoryPool         OBJECT IDENTIFIER ::= { mgs370012c 124 }

    sysMemoryPoolTable OBJECT-TYPE
               SYNTAX      SEQUENCE OF SysMemoryPoolEntry
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
              ""
    ::= { sysMemoryPool 1 }

    sysMemoryPoolEntry OBJECT-TYPE
        SYNTAX      SysMemoryPoolEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "A system memory pool entry"
        INDEX {
            sysMemoryPoolId
        }
    ::= { sysMemoryPoolTable 1 }

    SysMemoryPoolEntry ::=
        SEQUENCE {
            sysMemoryPoolId       Unsigned32,
            sysMemoryPoolName     OCTET STRING,
            sysMemoryPoolTotal    Unsigned32,
            sysMemoryPoolUsed     Unsigned32,
            sysMemoryPoolUtil     Unsigned32
        }

    sysMemoryPoolId OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
         "The memory pool id "
    ::= { sysMemoryPoolEntry 1 }

    sysMemoryPoolName OBJECT-TYPE
        SYNTAX      OCTET STRING(SIZE (0..32))
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
         "Name of the memory pool "
    ::= { sysMemoryPoolEntry 2 }

    sysMemoryPoolTotal OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "Total size of memory pool in bytes "
    ::= { sysMemoryPoolEntry 3 }

    sysMemoryPoolUsed OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "Used size of memory pool in bytes "
    ::= { sysMemoryPoolEntry 4 }

    sysMemoryPoolUtil OBJECT-TYPE
        SYNTAX      Unsigned32 (0..100)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "Utilization of memory pool in bytes "
    ::= { sysMemoryPoolEntry 5 }



--     ******************************************************************
-- *
--                  PPPoE IA
-- *
-- ******************************************************************

    pppoe    OBJECT IDENTIFIER ::= { mgs370012c 125 }
        pppoeIaSetup    OBJECT IDENTIFIER ::= { pppoe 1 }

        pppoeIaState    OBJECT-TYPE
        SYNTAX    EnabledStatus
        ACCESS    read-write
        STATUS    mandatory
        DESCRIPTION
                      ""
        ::= { pppoeIaSetup 1 }

        pppoeIaAccessNodeIdentifierString    OBJECT-TYPE
        SYNTAX    DisplayString
        ACCESS    read-write
        STATUS    mandatory
        DESCRIPTION
                          ""
        ::= { pppoeIaSetup 2 }

        pppoeIaFlexibleCircuitIDSyntaxActive OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { pppoeIaSetup 3 }

        pppoeIaFlexibleCircuitIDSyntaxIdentifierString OBJECT-TYPE
        SYNTAX    DisplayString
        ACCESS    read-write
        STATUS    mandatory
        DESCRIPTION
                           ""
        ::= { pppoeIaSetup 4 }

        pppoeIaFlexibleCircuitIDSyntaxOption OBJECT-TYPE
        SYNTAX  INTEGER {
            sp(1),
            sv(2),
            pv(3),
            spv(4)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { pppoeIaSetup 5 }

        pppoeIaFlexibleCircuitIDSyntaxDelimiter OBJECT-TYPE
        SYNTAX  INTEGER {
            pound-sign(1),
            dot(2),
            comma(3),
            semicolon(4),
            slash(5),
            space(6)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { pppoeIaSetup 6 }

--
--      pppoe ia interface table
--

        pppoeIaPortTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF PppoeIaPortEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { pppoeIaSetup 7 }

        pppoeIaPortEntry OBJECT-TYPE
        SYNTAX    PppoeIaPortEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        ""
        INDEX              { dot1dBasePort }
        ::= { pppoeIaPortTable 1 }

        PppoeIaPortEntry ::=
        SEQUENCE {
            pppoeIaPortEntryPort                INTEGER,
            pppoeIaPortEntryTrust                EnabledStatus,
            pppoeIaPortEntryCircuitIDString        DisplayString,
            pppoeIaPortEntryRemoteIDString        DisplayString
        }

        pppoeIaPortEntryPort OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { pppoeIaPortEntry 1 }

        pppoeIaPortEntryTrust OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { pppoeIaPortEntry 2 }

        pppoeIaPortEntryCircuitIDString OBJECT-TYPE
        SYNTAX    DisplayString
        ACCESS    read-write
        STATUS    mandatory
        DESCRIPTION
                           ""
        ::= { pppoeIaPortEntry 3 }

        pppoeIaPortEntryRemoteIDString OBJECT-TYPE
        SYNTAX    DisplayString
        ACCESS    read-write
        STATUS    mandatory
        DESCRIPTION
                           ""
        ::= { pppoeIaPortEntry 4 }


--
--      pppoe ia vlan table
--
        pppoeIaVlanTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF PppoeIaVlanEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { pppoeIaSetup 8 }

        pppoeIaVlanEntry OBJECT-TYPE
        SYNTAX    PppoeIaVlanEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        ""
        INDEX              { pppoeIaVlanEntryVid }
        ::= { pppoeIaVlanTable 1 }

        PppoeIaVlanEntry ::=
        SEQUENCE {
            pppoeIaVlanEntryVid                INTEGER,
            pppoeIaVlanEntryCircuitID        EnabledStatus,
            pppoeIaVlanEntryRemoteID        EnabledStatus,
            pppoeIaVlanEntryRowStatus        RowStatus
        }

        pppoeIaVlanEntryVid    OBJECT-TYPE
        SYNTAX  INTEGER (1..4094)
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { pppoeIaVlanEntry 1 }

        pppoeIaVlanEntryCircuitID    OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { pppoeIaVlanEntry 2 }

        pppoeIaVlanEntryRemoteID    OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { pppoeIaVlanEntry 3 }

        pppoeIaVlanEntryRowStatus    OBJECT-TYPE
        SYNTAX  RowStatus
        ACCESS  read-create
        STATUS  mandatory
        DESCRIPTION
                        ""
        ::= { pppoeIaVlanEntry 4 }

--
--      pppoe ia port and vlan table
--
        pppoeIaPortVlanTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF PppoeIaPortVlanEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { pppoeIaSetup 9 }

        pppoeIaPortVlanEntry OBJECT-TYPE
        SYNTAX    PppoeIaPortVlanEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in pppoe ia port & vlan table"
        INDEX              { pppoeIaPortVlanEntryPort, pppoeIaPortVlanEntryVid }
        ::= { pppoeIaPortVlanTable 1 }

        PppoeIaPortVlanEntry ::=
           SEQUENCE {
            pppoeIaPortVlanEntryPort                INTEGER,
            pppoeIaPortVlanEntryVid                    INTEGER,
            pppoeIaPortVlanEntryCircuitIDString        DisplayString,
            pppoeIaPortVlanEntryRemoteIDString        DisplayString,
             pppoeIaPortVlanEntryRowStatus            RowStatus
           }
        pppoeIaPortVlanEntryPort OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                         "interface port id"
        ::= { pppoeIaPortVlanEntry 1 }

        pppoeIaPortVlanEntryVid OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                         "vid"
        ::= { pppoeIaPortVlanEntry 2 }

        pppoeIaPortVlanEntryCircuitIDString OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "The circuit-id string of pppoe ia port & vlan entry"
        ::= { pppoeIaPortVlanEntry 3 }

       pppoeIaPortVlanEntryRemoteIDString OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "The remote-id string of pppoe ia port & vlan entry"
        ::= { pppoeIaPortVlanEntry 4 }

        pppoeIaPortVlanEntryRowStatus OBJECT-TYPE
        SYNTAX  RowStatus
        ACCESS  read-create
        STATUS  mandatory
        DESCRIPTION
                         ""
        ::= { pppoeIaPortVlanEntry 5 }

-- ******************************************************************
--    126.Private Vlan mib
-- ******************************************************************
    privateVLANSetup    OBJECT IDENTIFIER ::= { mgs370012c 126 }

    privateVLANTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF PrivateVLANEntry
        MAX-ACCESS  not-accessible
        STATUS      mandatory
        DESCRIPTION
                ""
        ::= { privateVLANSetup 1 }

    privateVLANEntry OBJECT-TYPE
        SYNTAX      PrivateVLANEntry
        MAX-ACCESS  not-accessible
        STATUS      mandatory
        DESCRIPTION ""
        INDEX { vlanCounterVlanID}
        ::= { privateVLANTable 1 }

    PrivateVLANEntry ::=
        SEQUENCE {
            privateVLANName               DisplayString,
            privateVLANVid                INTEGER,
            privateVLANPromiscuousPorts   PortList,
            privateVLANRowStatus          RowStatus
       }

    privateVLANName OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-write
        STATUS      mandatory
        DESCRIPTION
             " Private VLAN name."
        ::= { privateVLANEntry 1 }

    privateVLANVid OBJECT-TYPE
        SYNTAX      INTEGER (1..4094)
        MAX-ACCESS  read-write
        STATUS      mandatory
        DESCRIPTION
             " Private VLAN ID."
        ::= { privateVLANEntry 2 }

    privateVLANPromiscuousPorts OBJECT-TYPE
        SYNTAX      PortList
        MAX-ACCESS  read-write
        STATUS      mandatory
        DESCRIPTION
             " Private VLAN promiscuous ports."
        ::= { privateVLANEntry 3 }

    privateVLANRowStatus OBJECT-TYPE
        SYNTAX      RowStatus
        MAX-ACCESS  read-write
        STATUS      mandatory
        DESCRIPTION
             ""
        ::= { privateVLANEntry 4 }

---------------------------------------------------
--
--  errdisable
--
---------------------------------------------------

    errdisable         OBJECT IDENTIFIER ::= { mgs370012c 130 }

    recovery             OBJECT IDENTIFIER ::= { errdisable 1 }


    errdisableRecoverySetup  OBJECT IDENTIFIER ::= { recovery 1 }

        errdisableRecoveryState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { errdisableRecoverySetup 1 }

    --errdisableRecoveryReasonTable
    errdisableRecoveryReasonTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF ErrdisableRecoveryReasonEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { errdisableRecoverySetup 2 }

    errdisableRecoveryReasonEntry OBJECT-TYPE
        SYNTAX    ErrdisableRecoveryReasonEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        ""
        INDEX              { errdisableRecoveryReason }
        ::= { errdisableRecoveryReasonTable 1 }

        ErrdisableRecoveryReasonEntry ::=
           SEQUENCE {
            errdisableRecoveryReason    INTEGER,
            errdisableRecoveryReasonActive    EnabledStatus,
            errdisableRecoveryReasonInterval    INTEGER
           }

        errdisableRecoveryReason OBJECT-TYPE
        SYNTAX  INTEGER {
            loopguard(0),
            arp(1),
            bpdu(2),
            igmp(3),
            icmp(4)
        }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { errdisableRecoveryReasonEntry 1 }

        errdisableRecoveryReasonActive OBJECT-TYPE
        SYNTAX  INTEGER {
                enabled(1),
                disabled(2)
        }

        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { errdisableRecoveryReasonEntry 2 }

        errdisableRecoveryReasonInterval OBJECT-TYPE
        SYNTAX  INTEGER (30..2592000)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { errdisableRecoveryReasonEntry 3 }

    --errdisableRecoveryIfStatusTable
    errdisableRecoveryIfStatusTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF ErrdisableRecoveryIfStatusEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { errdisableRecoverySetup 3 }

    errdisableRecoveryIfStatusEntry OBJECT-TYPE
        SYNTAX    ErrdisableRecoveryIfStatusEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        ""
        INDEX              { errdisableRecoveryIfStatusReason,errdisableRecoveryIfStatusPort }
        ::= { errdisableRecoveryIfStatusTable 1 }

        ErrdisableRecoveryIfStatusEntry ::=
           SEQUENCE {
            errdisableRecoveryIfStatusReason    INTEGER,
            errdisableRecoveryIfStatusPort        INTEGER,
            errdisableRecoveryIfStatusTimeToRecover    INTEGER
           }

        errdisableRecoveryIfStatusReason OBJECT-TYPE
        SYNTAX  INTEGER {
            loopguard(0),
            arp(1),
            bpdu(2),
            igmp(3),
            icmp(4)
        }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { errdisableRecoveryIfStatusEntry 1 }

        errdisableRecoveryIfStatusPort OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { errdisableRecoveryIfStatusEntry 2 }

        errdisableRecoveryIfStatusTimeToRecover OBJECT-TYPE
        SYNTAX  INTEGER (30..2592000)
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { errdisableRecoveryIfStatusEntry 3 }

    detect             OBJECT IDENTIFIER ::= { errdisable 2 }


        errdisableDetectReasonTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF  ErrdisableDetectReasonEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { detect 1 }

           errdisableDetectReasonEntry OBJECT-TYPE
        SYNTAX    ErrdisableDetectReasonEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in errdisableDetectReasonTable."
        INDEX              { errdisableDetectReason }
        ::= { errdisableDetectReasonTable 1 }

        ErrdisableDetectReasonEntry ::=
    SEQUENCE {
            errdisableDetectReason    INTEGER,
            errdisableDetectReasonEnable    EnabledStatus,
            errdisableDetectReasonMode    INTEGER
         }


        errdisableDetectReason OBJECT-TYPE
        SYNTAX  INTEGER{
            arp(1),
            bpdu(2),
            igmp(3),
            icmp(4)
           }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { errdisableDetectReasonEntry 1 }



        errdisableDetectReasonEnable OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { errdisableDetectReasonEntry 2 }


        errdisableDetectReasonMode OBJECT-TYPE
        SYNTAX  INTEGER{
            inactive-port(1),
            inactive-reason(2),
            rate-limitation(3)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          ""
        ::= { errdisableDetectReasonEntry 3 }

    errdisableTrapInfoObject  OBJECT IDENTIFIER ::= { errdisable 3 }

    errdisableTrapPort OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { errdisableTrapInfoObject 1 }

    errdisableTrapReason OBJECT-TYPE
        SYNTAX  INTEGER
        {
            loopguard(0),
            arp(1),
            bpdu(2),
            igmp(3),
            icmp(4)
        }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { errdisableTrapInfoObject 2 }


    errdisableTrapMode  OBJECT-TYPE
        SYNTAX  INTEGER
        {
            inactive-port(0),
            inactive-reason(1),
            rate-limitation(2)
        }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                      ""
        ::= { errdisableTrapInfoObject 3 }


    errdisableTrapNotifications  OBJECT IDENTIFIER ::= { errdisable 4 }
        errdisableDetectTrap NOTIFICATION-TYPE
        OBJECTS {
               errdisableTrapPort,
               errdisableTrapReason,
               errdisableTrapMode
        }
        STATUS  current
        DESCRIPTION
         ""
        ::= { errdisableTrapNotifications 1 }

        errdisableRecoveryTrap NOTIFICATION-TYPE
        OBJECTS {
               errdisableTrapPort,
               errdisableTrapReason,
               errdisableTrapMode
        }
        STATUS  current
        DESCRIPTION
         ""
        ::= { errdisableTrapNotifications 2 }

---------------------------------------------------
--
--  131. CPU protection
--
---------------------------------------------------

    cpuProtectionSetup     OBJECT IDENTIFIER ::= { mgs370012c 131 }


     cpuProtectionTable    OBJECT-TYPE
        SYNTAX    SEQUENCE OF CPUProtectionEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { cpuProtectionSetup 1 }

        cpuProtectionEntry OBJECT-TYPE
        SYNTAX    CPUProtectionEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in CPUProtectionTable."
        INDEX              { cpuProtectionPort, cpuProtectionReason}
        ::= { cpuProtectionTable 1 }

        CPUProtectionEntry ::=
    SEQUENCE {
            cpuProtectionPort          INTEGER,
            cpuProtectionReason        INTEGER,
            cpuProtectionRateLimitSet     INTEGER
          }

        cpuProtectionPort OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "The Protected Port"
        ::= { cpuProtectionEntry 1 }


        cpuProtectionReason OBJECT-TYPE
        SYNTAX  INTEGER{
            arp(1),
            bpdu(2),
            igmp(3),
            icmp(4)
        }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                          "The Protected Reason"
        ::= { cpuProtectionEntry 2}


        cpuProtectionRateLimitSet OBJECT-TYPE
        SYNTAX  INTEGER(0..256)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "The rate limit of a reason on a port"
        ::= { cpuProtectionEntry 3}

--  macSetup
    macSetup         OBJECT IDENTIFIER ::= { mgs370012c 135 }

--  macTable
        flushAll OBJECT-TYPE
        SYNTAX  INTEGER{
            inactive(0),
            active(1)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
        "Flush all macs."
        ::= { macSetup 1 }

        flushPort OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
        "Flush macs on a specific port."
        ::= { macSetup 2 }

-- greenEthernetSetup
    greenEthernetSetup OBJECT IDENTIFIER ::= { mgs370012c 150 }

        greenEthernetAutoPowerDownState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "Enable/Disable Auto Power Down"
        ::= { greenEthernetSetup 2 }

-- greenEthernetPortTable

        greenEthernetPortTable OBJECT-TYPE
        SYNTAX    SEQUENCE OF GreenEthernetPortEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                     ""
        ::= { greenEthernetSetup 4 }

    greenEthernetPortEntry OBJECT-TYPE
        SYNTAX    GreenEthernetPortEntry
        ACCESS    not-accessible
        STATUS    mandatory
        DESCRIPTION        "An entry in greenEthernetPortTable."
        INDEX              { dot1dBasePort }
        ::= { greenEthernetPortTable 1 }

        GreenEthernetPortEntry ::=
           SEQUENCE {
            greenEthernetPortAutoPowerDownState    EnabledStatus
           }

        greenEthernetPortAutoPowerDownState OBJECT-TYPE
        SYNTAX  EnabledStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                          "Enable/Disable Auto Power Down by port."
        ::= { greenEthernetPortEntry 2 }