-- Version: 7.04.05
-- Date of Last Update: 2/18/2010
-- Modified by: Richard King (since 5/2005)
-- Fourth Author: Wai Tai (12/2001 to 6/2004)
-- Third Author: Srinivas Tummala (6/2001 to 11/2001)
-- Second Author: Wai Tai (since 4/2000 to 5/2001)
-- Original Author: Rasta A. Mansour (9/1999)
--
-- Description: This MIB describes the manageable elements for the
-- LuxN optical fiber transmission product.  This MIB
-- is based on SNMPv1 MIB-2 specification.
--
-- Copyright (c) 2001 to 2003 - LuxN, Inc.
-- All Rights Reserved
--
-- History of Changes:
--

LUXN-MIB DEFINITIONS ::= BEGIN

        IMPORTS
                enterprises, Counter,
                Gauge, IpAddress        FROM RFC1155-SMI

                DisplayString           FROM RFC1213-MIB

                OBJECT-TYPE             FROM RFC-1212

                TRAP-TYPE               FROM RFC-1215;


        -- Full OID: iso org(3) dod(6) internet(1) private(4)
        -- enterprises (1)  1.3.6.1.4.1.4253

        luxN            OBJECT IDENTIFIER ::= { enterprises 4253 }


        -- groups in luxN mib

        configuration   OBJECT IDENTIFIER ::= { luxN 1 }
        performance     OBJECT IDENTIFIER ::= { luxN 2 }
        faults          OBJECT IDENTIFIER ::= { luxN 3 }
        security        OBJECT IDENTIFIER ::= { luxN 4 }
        accounting      OBJECT IDENTIFIER ::= { luxN 5 }

        -- subgroups in the configuration group

        manufacturing   OBJECT IDENTIFIER ::= { configuration 1 }
        cp              OBJECT IDENTIFIER ::= { configuration 2 }
        cc              OBJECT IDENTIFIER ::= { configuration 3 }
        mux             OBJECT IDENTIFIER ::= { configuration 4 }
        ps              OBJECT IDENTIFIER ::= { configuration 5 }
        download        OBJECT IDENTIFIER ::= { configuration 6 }
        fadm            OBJECT IDENTIFIER ::= { configuration 7 }
        oppm            OBJECT IDENTIFIER ::= { configuration 8 }
        mcm             OBJECT IDENTIFIER ::= { configuration 9 }
        fn              OBJECT IDENTIFIER ::= { configuration 10 }
        csim            OBJECT IDENTIFIER ::= { configuration 11 }
        rpsm            OBJECT IDENTIFIER ::= { configuration 12 }
        rsdm            OBJECT IDENTIFIER ::= { configuration 13 }
        rtdm            OBJECT IDENTIFIER ::= { configuration 14 }
        osam            OBJECT IDENTIFIER ::= { configuration 15 }
        rsm             OBJECT IDENTIFIER ::= { configuration 16 }
        upsm            OBJECT IDENTIFIER ::= { configuration 17 }
        mcmesc          OBJECT IDENTIFIER ::= { configuration 18 }
        systemConfig    OBJECT IDENTIFIER ::= { configuration 21 }
        topology        OBJECT IDENTIFIER ::= { configuration 22 }
        routing         OBJECT IDENTIFIER ::= { configuration 23 }
        ring            OBJECT IDENTIFIER ::= { configuration 24 }
        tap             OBJECT IDENTIFIER ::= { configuration 25 }
        voadm           OBJECT IDENTIFIER ::= { configuration 26 }
        zmsConfigSync   OBJECT IDENTIFIER ::= { configuration 27 }
        dmm             OBJECT IDENTIFIER ::= { configuration 28 }
        ocm10gf         OBJECT IDENTIFIER ::= { configuration 29 }
        ocm2            OBJECT IDENTIFIER ::= { configuration 30 }
        osc             OBJECT IDENTIFIER ::= { configuration 31 }
        ocm4g           OBJECT IDENTIFIER ::= { configuration 32 }
        oet             OBJECT IDENTIFIER ::= { configuration 33 }
        uob             OBJECT IDENTIFIER ::= { configuration 34 }
        fc8g            OBJECT IDENTIFIER ::= { configuration 35 }

        -- subgroups of the performance group

        current1           OBJECT IDENTIFIER ::= { performance 1 }
        historical         OBJECT IDENTIFIER ::= { performance 2 }
        specialConditions  OBJECT IDENTIFIER ::= { performance 3 }

        -- subgroups of the current subgroup

        systemPerf      OBJECT IDENTIFIER ::= { current1 1 }
        downloadPerf    OBJECT IDENTIFIER ::= { current1 2 }
        cpPerf          OBJECT IDENTIFIER ::= { current1 3 }
        ccPerf          OBJECT IDENTIFIER ::= { current1 4 }
        muxPerf         OBJECT IDENTIFIER ::= { current1 5 }
        psPerf          OBJECT IDENTIFIER ::= { current1 6 }
        fadmPerf        OBJECT IDENTIFIER ::= { current1 7 }
        oppmPerf        OBJECT IDENTIFIER ::= { current1 8 }
        mcmPerf         OBJECT IDENTIFIER ::= { current1 9 }    
        fnPerf          OBJECT IDENTIFIER ::= { current1 10 }
        csimPerf        OBJECT IDENTIFIER ::= { current1 11 }
        rpsmPerf        OBJECT IDENTIFIER ::= { current1 12 }
        rsdmPerf        OBJECT IDENTIFIER ::= { current1 13 }
        rtdmPerf        OBJECT IDENTIFIER ::= { current1 14 }
        osamPerf        OBJECT IDENTIFIER ::= { current1 15 }
        rsmPerf         OBJECT IDENTIFIER ::= { current1 16 }
        upsmPerf        OBJECT IDENTIFIER ::= { current1 17 }
        mcmescPerf      OBJECT IDENTIFIER ::= { current1 18 }
        routingPerf     OBJECT IDENTIFIER ::= { current1 21 }
        tapPerf         OBJECT IDENTIFIER ::= { current1 22 }
        voadmPerf       OBJECT IDENTIFIER ::= { current1 23 }
        dmmPerf         OBJECT IDENTIFIER ::= { current1 24 }
        ocm10gfPerf     OBJECT IDENTIFIER ::= { current1 25 }
        ocm2Perf        OBJECT IDENTIFIER ::= { current1 26 }
        oscPerf         OBJECT IDENTIFIER ::= { current1 27 }
        ocm4gPerf       OBJECT IDENTIFIER ::= { current1 28 }
        oetPerf         OBJECT IDENTIFIER ::= { current1 29 }
        uobPerf         OBJECT IDENTIFIER ::= { current1 30 }
        fc8gPerf        OBJECT IDENTIFIER ::= { current1 31 }

        -- subgroups of the historical subgroup

        systemHist      OBJECT IDENTIFIER ::= { historical 1 }
        downloadHist    OBJECT IDENTIFIER ::= { historical 2 }
        cpHist          OBJECT IDENTIFIER ::= { historical 3 }
        ccHist          OBJECT IDENTIFIER ::= { historical 4 }
        muxHist         OBJECT IDENTIFIER ::= { historical 5 }
        psHist          OBJECT IDENTIFIER ::= { historical 6 }
        fadmHist        OBJECT IDENTIFIER ::= { historical 7 }
        oppmHist        OBJECT IDENTIFIER ::= { historical 8 }
        mcmHist         OBJECT IDENTIFIER ::= { historical 9 }
        fnHist          OBJECT IDENTIFIER ::= { historical 10 }
        csimHist        OBJECT IDENTIFIER ::= { historical 11 }
        rpsmHist        OBJECT IDENTIFIER ::= { historical 12 }
        rsdmHist        OBJECT IDENTIFIER ::= { historical 13 }
        rtdmHist        OBJECT IDENTIFIER ::= { historical 14 } 
        osamHist        OBJECT IDENTIFIER ::= { historical 15 }
        rsmHist         OBJECT IDENTIFIER ::= { historical 16 }
        upsmHist        OBJECT IDENTIFIER ::= { historical 17 } 
        mcmescHist      OBJECT IDENTIFIER ::= { historical 18 }
        tapHist         OBJECT IDENTIFIER ::= { historical 19 }
        voadmHist       OBJECT IDENTIFIER ::= { historical 20 }
        dmmHist         OBJECT IDENTIFIER ::= { historical 21 }
        ocm10gfHist     OBJECT IDENTIFIER ::= { historical 22 }
        ocm2Hist        OBJECT IDENTIFIER ::= { historical 23 }
        oscHist         OBJECT IDENTIFIER ::= { historical 24 }
        ocm4gHist       OBJECT IDENTIFIER ::= { historical 25 }
        oetHist         OBJECT IDENTIFIER ::= { historical 26 }
        uobHist         OBJECT IDENTIFIER ::= { historical 27 }

        -- subgroups of the specialConditions subgroup

        systemCond      OBJECT IDENTIFIER ::= { specialConditions 1 }
        downloadCond    OBJECT IDENTIFIER ::= { specialConditions 2 }
        cpCond          OBJECT IDENTIFIER ::= { specialConditions 3 }
        ccCond          OBJECT IDENTIFIER ::= { specialConditions 4 }
        muxCond         OBJECT IDENTIFIER ::= { specialConditions 5 }
        psCond          OBJECT IDENTIFIER ::= { specialConditions 6 }
        fadmCond        OBJECT IDENTIFIER ::= { specialConditions 7 }
        oppmCond        OBJECT IDENTIFIER ::= { specialConditions 8 }
        mcmCond         OBJECT IDENTIFIER ::= { specialConditions 9 }
        fnCond          OBJECT IDENTIFIER ::= { specialConditions 10 }
        rpsmCond        OBJECT IDENTIFIER ::= { specialConditions 12 }
        rsdmCond        OBJECT IDENTIFIER ::= { specialConditions 13 }
        rtdmCond        OBJECT IDENTIFIER ::= { specialConditions 14 } 
        osamCond        OBJECT IDENTIFIER ::= { specialConditions 15 }
        rsmCond         OBJECT IDENTIFIER ::= { specialConditions 16 }
        upsmCond        OBJECT IDENTIFIER ::= { specialConditions 17 } 

        -- subgroups of the faults group

        eventLog        OBJECT IDENTIFIER ::= { faults 1 }
        userLog         OBJECT IDENTIFIER ::= { faults 2 }
        diagnostics     OBJECT IDENTIFIER ::= { faults 3 }
        alarmLog        OBJECT IDENTIFIER ::= { faults 4 }

        -- subgroups of the diagnostics group
        
        diagSelfTest    OBJECT IDENTIFIER ::= { diagnostics 5 }

        -- subgroups of the diagSelfTest group

        mcmescSelfTest  OBJECT IDENTIFIER ::= { diagSelfTest 1 }

        -- place holder here for other module's self test in the future:
        -- newModuleSelfTest  OBJECT IDENTIFIER ::= { diagSelfTest 2 }

        -- subgroups of the security group

        userSecMgmt     OBJECT IDENTIFIER ::= { security 1 }
        systemSecMgmt   OBJECT IDENTIFIER ::= { security 2 }
        netSecMgmt      OBJECT IDENTIFIER ::= { security 3 }

        -- subgroups of the security group

        radiusSecMgmt   OBJECT IDENTIFIER ::= { netSecMgmt 1 }
        sshSecMgmt      OBJECT IDENTIFIER ::= { netSecMgmt 2 }


        -- subgroups of the accounting group

        cpAcct          OBJECT IDENTIFIER ::= { accounting 1 }
        ccAcct          OBJECT IDENTIFIER ::= { accounting 2 }
        mcmAcct         OBJECT IDENTIFIER ::= { accounting 3 }
        mcmescAcct      OBJECT IDENTIFIER ::= { accounting 4 }

        --
        -- Global Data types
        --

        -- Textual conventions for the FlagType data type
        --
        -- on means enabled
        -- off means disabled
        --

        FlagType        ::= INTEGER { on(1), off(2) }

        --
        -- Global Data types
        --

        -- Textual conventions for the ResetType data type
        --
        -- Other is used for only get purpose
        -- Reset means set the flag to OFF or FALSE or whatever
        -- means reset

        ResetType       ::= INTEGER { other(1), reset(2) }

        -- Textual conventions for the RebootType data type
        --
        -- Other is used for only get purpose
        -- warmboot means to reboot the particular card chosen
        --

        RebootType      ::= INTEGER { other(1), warmboot(2) }


        -- Textual conventions for the Boolean data type
        --
        -- True or 'Y' is 1, False or 'N' is 2
        --

        Boolean         ::= INTEGER { true(1), false(2) }


        -- Textual conventions for the ChassisType data type

        ChassisType     ::= INTEGER { wavstation1(1), gm3234(2), gm3217(3), gm1602(4), gm1608(5), gmx128(6) }

        -- Textual conventions for the CardLocation data type
        --
        -- 1 means local, 2 means remote link 1, 3 means remote link 2
        --

        CardLocation    ::= INTEGER { local(1), remote1(2), remote2(3) }


        -- Textual conventions for the CardShelf data type
        --
        -- There could be up to 2 shelves per Chassis
        --

        CardShelf       ::= INTEGER (1..2)


        -- Textual conventions for the CardSlot data type
        --
        -- There could be up to 17 card slots per shelf
        --

        CardSlot        ::= INTEGER (1..17)


        -- Textual conventions for the ShelfInput data type
        --

        ShelfInput      ::= INTEGER (0..2)


        -- Textual conventions for the SlotInput data type
        --

        SlotInput       ::= INTEGER (0..17)


        -- Textual conventions for the CardName data type
        --
        -- Card name may be any alpha-numeric character string
        -- up to 32 characters.

        CardName        ::= DisplayString (SIZE (0..32))

        -- Textual conventions for the LinkName data type
        --
        -- Link name may be any alpha-numeric character string
        -- up to 40 characters.

        LinkName        ::= DisplayString (SIZE (0..40))

        -- Textual conventions for the CardType data type
        --
        -- There could be up to 20 different card type
        -- 

        CardType        ::= INTEGER 
                            {
                                empty(0),
                                mpm(1),
                                ocmu(2),
                                ocmi(3),
                                ofcm(4),
                                ofcd(5),
                                fadm(6),
                                oppm(7),
                                mcmt1(8),
                                oli(9),
                                w4cd(10),
                                w2cmd(13),
                                osam(20),
                                w4cm(21),
                                rsm(22),
                                upsm(23),
                                ocme(24),
                                oci(25),
                                oxc(26),
                                ocm10g(27),
                                osamlp(29),
                                osamhp(30),
                                mcmesc(33),
                                wfadm(34),
                                mcme1(35),
                                md100-1(36),
                                md100-40(37),
                                tap(38),
                                md100-5(39),
                                md100-10(40),
                                ocm10glr(41),
                                bd-4(42),
                                bp-10(43),
                                unknown(44),
                                dmm(45),
                                bp-5(46),
                                mpm2(47),
                                osc(48),
                                ocm2(49),
                                ocm10gf(50),
                                ocm2-4g(51),
                                oet(52),
                                uob(53),
                                fc8g(54),
                                md100p(55),
                                cwdm_bd4(56)
                            }

        -- Textual conventions for the CardStatus data type
        --
        -- The status' are: Critical, Major, Minor, and Normal.
        --
        -- Critical means that the device is experiencing a
        -- service outage.
        -- Major means that a service affecting fault exists.
        -- Minor means that a fault exists but it is not service
        -- affecting.
        -- Normal means all is well and the card is functioning
        -- acknowledged means that a fault of critical minor or major severity exists
        -- and is acknowledged by the user!

        -- properly.
        --

        CardStatus      ::= INTEGER { critical(1), major(2), minor(3), normal(4), acknowledged(5) }

        -- Textual conventions for the CardState data type
        --
        -- The states are: online, offline, empty, loopback, diag
        --
        -- online means the card is in the slot and working.
        -- offline means the card is in the slot but currently
        -- not working.
        -- empty means that the slot is empty (no card)
        -- loopback means the card is put in the loopback mode.
        -- diag means the card is put in the diagnostic test mode.
        --

        CardState       ::= INTEGER { empty(1), online(2), offline(3), loopback(4), diag(5) }


        -- Textual conventions for the RedundancyMode data type
        --
        -- Several cards, like CP or PS can have a redundant pair.
        -- This data type is used to indicate the state of those cards.
        --

        RedundancyMode  ::= INTEGER { active(1), standby(2) }


        -- Textual conventions for the Node Name data type
        -- Node name may be any alpha-numeric character string
        -- up to 32 characters.

        NodeName        ::= DisplayString(SIZE(0..32))


        -- Textual conventions for the Port Index data type
        -- There could be up 16 ports per card
        --
    
        PortIndex       ::= INTEGER(1..16)


        -- Textual conventions for the CardCycleMode data type
        --
        -- Each card can be cycled according to the following modes:
        --
        -- Request the card to be coldbooted (full initialization).
        -- Request the card to be warmbooted (new executable software loaded)
        -- Request the card to go offline
        -- Request the card to come back online
        -- Request the card to go into loopback mode
        -- Request the card to go into diagnostic mode
        --

        CardCycleMode   ::= INTEGER { coldboot(1), warmboot(2), offline(3), online(4), loopback(5), diag(6) }


        -- Textual conventions for the TrapStatus data type
        --
        -- The status' are: Critical, Major, Minor, Normal, and Clear.
        --
        -- Critical means that the device is experiencing a service outage.
        -- Major means that a service affecting fault exists.
        -- Minor means that a fault exists but it is not service affecting.
        -- Normal means all is well and the card is functioning properly.
        -- This trap status is treated as informational.
        -- Clear means that all previous alarms are cleared, and the
        -- current system status is Normal.
        --

        TrapStatus      ::= INTEGER { critical(1), major(2), minor(3), normal(4), clear(5) }


        -- Textual conventions for the CardState data type
        -- Textual conventions for the HistoryMode data type
        --
        -- Two types of historical counters are maintained.  One counter is
        -- the daily counter set.  It aggregates the 15 minute performance
        -- counters into one daily sum counter.  At the end of the day,
        -- this counter is reset.  The second counter is the perpetual
        -- longterm counter.  This counter aggregates the 15 minute
        -- performance counters for an indefinite amount of time.  When
        -- the counter exceeds the maximum value, it will wrap around.
        --

        HistoryMode     ::= INTEGER { daily(1), longterm(2) }


        -- Textual conventions for the EventBuffer data type
        --
        -- There could be up to 1000 event log entries
        -- maintained by the system in FIFO order.
        --

        EventBuffer     ::= INTEGER (1..1000)

        -- Textual conventions for the UserBuffer data type
        --
        -- There could be up to 100 user action log entries
        -- maintained by the system in FIFO order.
        --

        UserBuffer      ::= INTEGER (1..100)


        -- Textual conventions for the LogonID data type
        --
        -- Logon ID is in printable ASCII character set, and up to 15
        -- chars.
        -- A NULL value indicates no valid Logon ID is specified.
        --

        LogonID         ::= DisplayString (SIZE (0..15))


        -- Textual conventions for the HashedPasswd data type
        --
        -- Passwords maintained by the embedded LuxN application are
        -- hashed (one-way encrypted) to protect them from
        -- unauthorized view.  A simple hashing (message digest)
        -- algorithm like the one below can be used to hide the
        -- passwords.  LuxN passwords are only used to compare
        -- against, so it's OK to hash them.
        --
        -- Let N be the length of the clear text password, up to 10
        -- bytes. Let M be Twice maximum password length.  Exactly
        -- 20 bytes.  Let R be the number of rounds of hashing.  Say
        -- 10.  Let the password be stored in an array P with
        -- dimension M.  Note, array P is indexed from 1 and not
        -- from 0 in the discussion below.
        --
        -- The following algorithm (due to Rasta Mansour) hashes
        -- the array P in a one-way manner with a very low
        -- probability of collision.
        --
        -- Fill the array P with the Password of Length N up
        -- to the value of M.  Simple cyclic copy of the clear
        -- text password will do.
        --
        -- Execute the following rounds of the alogrithm below
        -- on the array P.
        --
        --      For i=1 to R do
        --              For j=1 to M do
        --                      Let k = ((j + i) mod M) + 1
        --                      Let P[j] = (P[j] + (k * P[k])) mod 256
        --                      if (P[j] == 0)
        --                              Let P[j] = k + N
        --
        --                      Let k = ((k * N) mod M) + 1
        --                      Let c = P[j]
        --                      Let P[j] = P[k]
        --                      Let P[k] = c
        --

        HashedPasswd        ::= OCTET STRING (SIZE (1..20))

        EncryptedCommunity  ::= DisplayString (SIZE (0..32))


        -- Textual conventions for the FileName data type
        --
        -- file name may be any alpha-numeric character string up
        -- to 32 characters.
        --

        FileName        ::= DisplayString (SIZE (0..32))


        -- Textual conventions for the EntityName data type
        --
        -- EntityName is in printable ASCII character set, and up
        -- to 15 chars.
        -- A NULL value indicates no valid name is specified.
        --

        EntityName      ::= DisplayString (SIZE (0..15))


        -- Textual conventions for the Date and Time data type
        --
        --      field   Octets  Contents                Range
        --      -----   ------  --------------------    --------
        --        1       1-2   year                    0..65535
        --                (in big endian order)
        --        2        3    month                   1..12
        --        3        4    day                     1..31
        --        4        5    hour                    0..23
        --        5        6    minutes                 0..59
        --        6        7    seconds                 0..59
        --        7        8    deci-seconds            0..9
        --                 (100 milliseconds)
        --        8        9    direction from UTC      "+" | "-"
        --        9       10    hours from UTC          0..11
        --       10       11    minutes from UTC        0..59
        --
        -- Note, if only local time is known, then timezone information
        -- (fields 8-10) is not present.
        --
        -- If only date is known, then the time part (fields 5-11) is not
        -- present.
        --

        DateAndTime     ::= DisplayString (SIZE( 0..20 ))


        -- Textual conventions for the VersionString data type
        --
        -- A version string is in the form:
        --
        --  'V' major_num '.' minor_num '.' alpha_num
        --
        -- Where, major_num and minor_num can be any 3 digit number.  The
        -- alpha_num is any lower case alpha character.  An example of a
        -- version string in this syntax is: V1.05.c.
        --
        -- The rules for assignment (creation) of a version string are as
        -- follows:
        --
        -- 1.  If the interface or the functionality has significantly changed,
        --     the major_num is incremented.
        -- 2.  If bugs are fixed but the functionality and the interface are
        --     generally the same, the minor_num is incremented.
        -- 3.  For interium releases, specially during in-house testing, or
        --     as experimental engineering bug fix release to a client, the
        --     alpha_num is incremented.
        --

        VersionString   ::= DisplayString (SIZE (0..12))


        -- Textual conventions for the SerialString data type
        --
        -- Serial number may be any alpha numeric printable character string
        -- up to 17 characters.
        --

        SerialString    ::= DisplayString (SIZE (0..17))

        -- Textual conventions for the SfpSerialString data type
        --
        -- SFP Serial number may be any alpha numeric printable character string
        -- up to 24 characters.
        --

        SfpSerialString ::= DisplayString (SIZE (0..24))

        -- Textual conventions for the ModelString data type
        --
        -- Model Type may be any alpha numeric printable character string
        -- up to 10 characters.
        --

        ModelString     ::= DisplayString (SIZE (0..10))

        -- Textual conventions for the ModelNum data type
        --
        -- Model number may be any alpha numeric printable character string
        -- up to 15 characters.
        --

        ModelNum        ::= DisplayString (SIZE (0..15))

        -- For SW download support

        -- Textual conventions for the FtpMode data type
        FtpMode         ::= INTEGER { active(1), passive(2) }
    
        -- Textual conventions for the DownloadType data type
        DownloadType    ::= DisplayString (SIZE (0..32))

        -- Textual conventions for the DownloadLocation data type
        DownloadLocation ::= INTEGER { local(1), remote(2), remote2(3) }

        -- Textual conventions for the DownloadShelf data type
        DownloadShelf   ::= INTEGER (0..2)

        -- Textual conventions for the DownloadSlot data type
        DownloadSlot    ::= INTEGER (0..17)

        -- Textual conventions for the OSMode data type
        OSMode          ::= DisplayString (SIZE (0..10))

        -- Textual conventions for the ReleaseDate data type
        ReleaseDate     ::= DisplayString (SIZE (0..10))

        -- Textual conventions for the OSMode data type
        OSState         ::= INTEGER { operating(1), backup(2) }
        
        -- Textual conventions for the UpdateOSMode data type
        UpdateOSMode    ::= INTEGER { toggle(1), revert(2) }

        -- Textual conventions for the DownloadStatus data type
        DownloadStatus  ::= INTEGER { idle(1), ftp-inprogress(2), mod-inprogress(3) }

        -- Textual conventions for the RingID name data type
        RingIdName      ::= DisplayString (SIZE (0..16))

        -- Textual conventions for the PathID name data type
        PathIdName      ::= DisplayString (SIZE (0..16))

        -- Textual conventions for the Timezone data type
        Timezone        ::= INTEGER 
                            {
                                idlw(1),
                                nt(2),
                                ahst(3),
                                cat(4),
                                hst(5),
                                hdt(6),
                                yst(7),
                                ydt(8),
                                pst(9),
                                pdt(10),
                                mst(11),
                                mdt(12),
                                cst(13),
                                cdt(14),
                                est(15),
                                edt(16),
                                ast(17),
                                adt(18),
                                at(19),
                                wat(20),
                                gmt(21),
                                ut(22),
                                utc(23),
                                wet(24),
                                bst(25),
                                cet(26),
                                fwt(27),
                                met(28),
                                mewt(29),
                                swt(30),
                                mest(31),
                                mesz(32),
                                sst(33),
                                fst(34),
                                eet(35),
                                bt(36),
                                zp4(37),
                                zp5(38),
                                zp6(39),
                                zp7(40),
                                wast(41),
                                cct(42),
                                wadt(43),
                                jst(44),
                                act(45),
                                east(46),
                                gst(47),
                                eadt(48),
                                idle(49),
                                nzst(50),
                                nzt(51),
                                nzdt(52)
                            }

        -- Textual conventions for the AlarmType data type
        AlarmType        ::= INTEGER 
                            {
                                aircompr(1),
                                aircond(2),
                                airdryr(3),
                                batdschrg(4),
                                battery(5),
                                power(6),
                                clfan(7),
                                engine(8),
                                engoprg(9),
                                explgs(10),
                                fire(11),
                                firdetr(12),
                                flood(13),
                                fuse(14),
                                gen(15),
                                hiair(16),
                                hihum(17),
                                hitemp(18),
                                hiwtr(19),
                                intruder(20),
                                lwhum(21),
                                lwbatvg(22),
                                lwpres(23),
                                lwfuel(24),
                                lwtemp(25),
                                lwwtr(26),
                                cpmajor(27),
                                cpminor(28),
                                opendr(29),
                                pump(30),
                                rect(31),
                                recthi(32),
                                rectlo(33),
                                smoke(34),
                                toxicgas(35),
                                ventn(36),
                                na(37)
                            }

        -- Textual conventions for the ZmsAdminString data type
        ZmsAdminString ::= DisplayString  (SIZE (0..32))

        -- Textual conventions for the ZmsFileName data type
        ZmsFileName    ::= DisplayString  (SIZE (0..64))

        -- The elements in the manufacturing subgroup of the configuration group

        mfgName         OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..30))
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Manufacturing name of the device.  Up to 30 characters"
                ::= { manufacturing 1 }

        mfgDate         OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of manufacturing of the chassis"
                ::= { manufacturing 2 }

        mfgSerialNum    OBJECT-TYPE
                SYNTAX  SerialString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Serial # of the Chassis."
                ::= { manufacturing 3 }

        mfgModelType    OBJECT-TYPE
                SYNTAX  ModelString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Model type of the chassis. Up to 10 characters"
                ::= { manufacturing 4 }

        mfgDefaultID    OBJECT-TYPE
                SYNTAX  LogonID
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Default one-time user ID.  This ID should be used
                         for the first time access to the system.  This ID
                         will not be accepted once a real user ID is added."
                ::= { manufacturing 5 }

        mfgDfltPasswd   OBJECT-TYPE
                SYNTAX  HashedPasswd
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Default one-time password to go with the default
                         user ID.  The password may contain non-printable
                         characters up to 10 ASCII characters.  Passwords
                         are hashed and are for comparison only"
                ::= { manufacturing 6 }


        mfgNumShelves   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Number of shelves in the chassis.  This number
                         reflects the number of rows of the table below.
                         This number is automatically adjusted everytime
                         a row is added to the table below."
                ::= { manufacturing 9 }

        mfgShelfTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF MfgShelfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the number of shelves and the
                         number of slots per shelf in the chassis."
                ::= { manufacturing 10 }

        mfgShelfEntry   OBJECT-TYPE
                SYNTAX  MfgShelfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { mfgShelfID }
                ::= { mfgShelfTable 1 }

        MfgShelfEntry   ::=
                SEQUENCE 
                {
                        mfgShelfID              CardShelf,
                        mfgNumSlots             INTEGER
                }

        mfgShelfID      OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                    "Integer ID of each shelf in the chassis.  The shelf number
                     is always one for both GM1608 and GM3217.  In the case of
                     of GM3234, the bottom shelf is 1 while the top shelf is 2.
                     As for GMX128, the order of numbering is from the top shelf
                     to the bottom shelf.  In other words, the top shelf is
                     assigned 1."
                ::= { mfgShelfEntry 1 }

        mfgNumSlots     OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "total number of slots in a given shelf."
                ::= { mfgShelfEntry 2 }

        mfgCRCChecksum  OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..8))
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "32 bit CRC of the manufacturing section.  This CRC
                         is automatically calculated everytime information
                         is updated from the manufacturing section.  The
                         manufacturing section is static once the chassis
                         leaves the LuxN manufacturing premise."
                ::= { manufacturing 11 }

        mfgChassisType  OBJECT-TYPE
                SYNTAX  ChassisType 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Type of chassis."
                ::= { manufacturing 12 }

        mfgPsType       OBJECT-TYPE
                SYNTAX  INTEGER 
                        {
                            dcOny(1),
                            acOnly(2),
                            mixedDcAc(3),
                            unknown(4)
                        }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Type of power supplies."
                ::= { manufacturing 13 }

        mfgCleiNum      OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CLEI number for the chassis."
                ::= { manufacturing 14 }


        -- The elements in the cp subgroup of the configuration group

        cpIpAddress     OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "IP Address of the Active Communication Processor"
                ::= { cp 1 }

        cpNetMask       OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Net mask for the Active Communication Processor"
                ::= { cp 2 }

        cpMIBVersion    OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Version of the LuxN MIB implemented by this device.
                         This value may be reset everytime a new CP code
                         is downloaded."
                ::= { cp 3 }

        cpBootPromVer   OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the Boot PROM code"
                ::= { cp 4 }

        cpROMSize       OBJECT-TYPE
                SYNTAX  INTEGER (1..16384)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total Size of the ROM in Kilobyes"
                ::= { cp 5 }

        cpNumSubDiv     OBJECT-TYPE
                SYNTAX  INTEGER (1..20)
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of the subdivisions of the ROM."
                ::= { cp 6 }

        cpSubDivTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF CpSubDivEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the number of sub divisions
                         and the size of each subdivision in ROM memory"
                ::= { cp 7 }

        cpSubDivEntry   OBJECT-TYPE
                SYNTAX  CpSubDivEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { cpSubDivIndex }
                ::= { cpSubDivTable 1 }

        CpSubDivEntry   ::=
                SEQUENCE 
                {
                        cpSubDivIndex           INTEGER,
                        cpSubDivDescr           DisplayString,
                        cpSubDivSize            INTEGER,
                        cpSubDivOffset          OCTET STRING,
                        cpSubDivImgVersion      DisplayString,
                        cpSubDivImgDBVersion    DisplayString 
                }

        cpSubDivIndex   OBJECT-TYPE
                SYNTAX  INTEGER (1..20)
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Integer ID of each sub division in the ROM.  The order
                         of numbering is from the top of the ROM to the bottom
                         of the ROM."
                ::= { cpSubDivEntry 1 }

        cpSubDivDescr   OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..20))
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Display Name of each Sub Division in ROM"
                ::= { cpSubDivEntry 2 }

        cpSubDivSize    OBJECT-TYPE
                SYNTAX  INTEGER (1..3145728)
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Size of each sub division in ROM in bytes"
                ::= { cpSubDivEntry 3 }

        cpSubDivOffset  OBJECT-TYPE
                SYNTAX  OCTET STRING (SIZE (0..8))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Starting address of each sub division in the ROM
                         in HEX notation."
                ::= { cpSubDivEntry 4 }

          cpSubDivImgVersion    OBJECT-TYPE
                SYNTAX  DisplayString 
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Display Version of each Images in ROM."
                ::= { cpSubDivEntry 5 }

          cpSubDivImgDBVersion  OBJECT-TYPE
                SYNTAX  DisplayString 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Display Database Version of each Images in ROM."
                ::= { cpSubDivEntry  6 }

        cpTable         OBJECT-TYPE
                SYNTAX  SEQUENCE OF CpEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         active or standby communication processor"
                ::= { cp 8 }

        cpEntry         OBJECT-TYPE
                SYNTAX  CpEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { cpCardShelf, cpCardSlot }
                ::= { cpTable 1 }

        CpEntry         ::=
                SEQUENCE 
                {
                        cpCardShelf             CardShelf,
                        cpCardSlot              INTEGER,
                        cpMode                  RedundancyMode,
                        cpDsgntdMode            RedundancyMode,
                        cpState                 CardState,
                        cpMacAddr               OCTET STRING,
                        cpName                  CardName,
                        cpMfgDate               DateAndTime,
                        cpSerialNum             SerialString,
                        cpModelType             INTEGER,
                        cpFWVersionID           VersionString,
                        cpSetState              INTEGER,
                        cpHWName                DisplayString,
                        cpCleiNum               DisplayString,
                        cpModelNum              DisplayString
                }


        cpCardShelf     OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in."
                ::= { cpEntry 1 }

        cpCardSlot      OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { cpEntry 2 }


        cpMode          OBJECT-TYPE
                SYNTAX  RedundancyMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Type of the communication processor.  The valid types
                         are Active or Standby."
                ::= { cpEntry 3 }

        cpDsgntdMode    OBJECT-TYPE
                SYNTAX  RedundancyMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Designation Type of the communication processor.  The
                         valid types are Active or Standby."
                ::= { cpEntry 4 }

        cpState         OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The state of the CP card."
                ::= { cpEntry 5 }

        cpMacAddr       OBJECT-TYPE
                SYNTAX  OCTET STRING (SIZE (0..6))
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MAC address of the Communication processor in HEX"
                ::= { cpEntry 6 }



        cpName          OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..32))
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Display (Network) name of the Communication processor"
                ::= { cpEntry 7 }

        cpMfgDate       OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of manufacturing of the CP card"
                ::= { cpEntry 8 }

        cpSerialNum     OBJECT-TYPE
                SYNTAX  SerialString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Serial # of the CP card."
                ::= { cpEntry 9 }

        cpModelType     OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Model type of the CP."
                ::= { cpEntry 10 }

        cpFWVersionID   OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the CP FW code"
                ::= { cpEntry 11 }

        cpSetState      OBJECT-TYPE
                SYNTAX  RebootType   
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                    "Instruct the CP to do a warmboot. A get on this will
                     always return an other." 
                ::= { cpEntry 12 }


        cpHWName        OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..32))
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Display Hardware name of the CP Card."
                ::= { cpEntry 13 }

        cpCleiNum       OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CLEI number of the mux/dmux Card."
                ::= { cpEntry 14 }

        cpModelNum      OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Model number of the CP card. Up to 15 characters"
                ::= { cpEntry 15 }

        cpSetMode       OBJECT-TYPE
                SYNTAX  RedundancyMode
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Toggle the Active/Standby mode of the active CP."
                ::= { cp 9 }

        cpSNMPTrapHost1 OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "IP Address of the first SNMP Trap host.  A NULL IP
                         address means no TRAP should be sent to this address.
                         Duplicate IP addresses will be rejected."
                ::= { cp 10 }

        cpSNMPTrapHost2 OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "IP Address of the second SNMP Trap host.  A NULL IP
                         address means no TRAP should be sent to this address.
                         Duplicate IP addresses will be rejected."
                ::= { cp 11 }

        cpSNMPTrapHost3 OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "IP Address of the third SNMP Trap host.  A NULL IP
                         address means no TRAP should be sent to this address.
                         Duplicate IP addresses will be rejected."
                ::= { cp 12 }

        cpSNMPSendTrap  OBJECT-TYPE
                SYNTAX  Boolean
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "If set to true, traps will be sent out.  If set to
                         false, traps will not be sent out.  This variable
                         is reset to true (enable) on each boot cycle."
                ::= { cp 13 }

        cpGateway       OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Gateway IP Address of the Active Communication Processor.  A
                         NULL IP address means Gateway hasn't been configured."
                ::= { cp 14 }

        cpMaxSessions   OBJECT-TYPE
                SYNTAX  INTEGER (1..6)
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Maximum allowed Telnet Sessions on the Active Communication
                         Processor. Valid values are 1 to 6."
                ::= { cp 15 }

        cpSessionTimeout OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Maximum timeout (in seconds) that can be set for a
                         Telnet session on the Active Communication Processor.
                         Valid values are greater than 30 secs."                
                ::= { cp 16 }

        cpDate          OBJECT-TYPE
                SYNTAX  DateAndTime 
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Current Date on the Active Communication Processor.
                         The format is in the form of mm-dd-yy in which mm
                         is the two digit month, dd is the two digit day of
                         the month, and yy is the two digit year."
                ::= { cp 17 }

        cpTime          OBJECT-TYPE
                SYNTAX  DateAndTime 
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Current Time on the Active Communication Processor.
                         The format is in the form of hh:mm:ss in which
                         hh is the hour, mm is the minute and ss is the
                         second.  The valid values for hour goes from 0
                         to 23. In order to work with LuxN NMS, it needs to be
                         set to GMT time"
                ::= { cp 18 }

        cpGetCommunity  OBJECT-TYPE
                SYNTAX  EncryptedCommunity 
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "User configurable SNMP Get Community String."
                ::= { cp 19 }

        cpSetCommunity  OBJECT-TYPE
                SYNTAX  EncryptedCommunity
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "User Configurable SNMP Set Community String."
                ::= { cp 20 }

        cpSystemName    OBJECT-TYPE
                SYNTAX  DisplayString(SIZE(0..59)) 
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "User Configurable System Name."
                ::= { cp 21 }

        cpSNMPTrapCommunity1    OBJECT-TYPE
                SYNTAX  EncryptedCommunity 
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "User configurable trap community string for first trap host.
                         Will return an error if the corresponding trap host is
                         invalid or not set."
                ::= { cp 22 }

        cpSNMPTrapCommunity2    OBJECT-TYPE
                SYNTAX  EncryptedCommunity 
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "User configurable trap community string for second trap host.
                         Will return an error if the corresponding trap host is
                         invalid or not set."
                ::= { cp 23 }

        cpSNMPTrapCommunity3    OBJECT-TYPE
                SYNTAX  EncryptedCommunity 
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "User configurable trap community string for third trap host.
                         Will return an error if the corresponding trap host is
                         invalid or not set."
                ::= { cp 24 }

        cpHttp          OBJECT-TYPE
                SYNTAX  INTEGER {enabled(1), disabled(2)}
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "HTTP server enabled or not."
                ::= { cp 25 }

        cpIMNIpAddress  OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "IMN Ip address. Use for IP/IWM"
                ::= { cp 26 }

        cpUpsrMode      OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            enable(1),
                            disable(2)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "UPSR mode:  enable and disable."
                ::= { cp 27 }

        cpAutoModuleUpdate  OBJECT-TYPE
                SYNTAX  INTEGER
                {
                    enable(1),
                    disable(2)
                }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Flag to automatically enable/disable module update."
                ::= { cp 28 }

        cpSNMPTrapHost4 OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "IP Address of the fourth SNMP Trap host.  A NULL IP
                         address means no TRAP should be sent to this address.
             Duplicate IP addresses will be rejected."
                ::= { cp 29 }

        cpSNMPTrapHost5 OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "IP Address of the fifth SNMP Trap host.  A NULL IP
                         address means no TRAP should be sent to this address.
             Duplicate IP addresses will be rejected."
                ::= { cp 30 }


        cpSNMPTrapCommunity4    OBJECT-TYPE
                SYNTAX  EncryptedCommunity 
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "User configurable trap community string for fourth trap host.
                         Will return an error if the corresponding trap host is
                         invalid or not set."
                ::= { cp 31 }

        cpSNMPTrapCommunity5    OBJECT-TYPE
                SYNTAX  EncryptedCommunity 
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "User configurable trap community string for fifth trap host.
                         Will return an error if the corresponding trap host is
                         invalid or not set."
                ::= { cp 32 }

        cpSNMPTrapHostPort1     OBJECT-TYPE
                SYNTAX  INTEGER(0..65534)
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "User configurable trap port for the first trap host.
                         Default value is 162"
                ::= { cp 33 }


        cpSNMPTrapHostPort2     OBJECT-TYPE
                SYNTAX  INTEGER(0..65534)
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "User configurable trap port for the second trap host.
                         Default value is 162"
                ::= { cp 34 }

        cpSNMPTrapHostPort3     OBJECT-TYPE
                SYNTAX  INTEGER(0..65534)
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "User configurable trap port for the third trap host.
                         Default value is 162"
                ::= { cp 35 }

        cpSNMPTrapHostPort4     OBJECT-TYPE
                SYNTAX  INTEGER(0..65534)
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "User configurable trap port for the fourth trap host.
                         Default value is 162"
                ::= { cp 36 }

        cpSNMPTrapHostPort5     OBJECT-TYPE
                SYNTAX  INTEGER(0..65534)
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "User configurable trap port for the fifth trap host.
                         Default value is 162"
                ::= { cp 37 }

        cpRedunSubDivTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF CpRedunSubDivEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the number of sub divisions
                         and the size of each subdivision in ROM memory
                         of redundant (standby) MPM"
                ::= { cp 38 }

        cpRedunSubDivEntry   OBJECT-TYPE
                SYNTAX  CpRedunSubDivEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { cpRedunSubDivIndex }
                ::= { cpRedunSubDivTable 1 }

        CpRedunSubDivEntry   ::=
                SEQUENCE 
                {
                        cpRedunSubDivIndex          INTEGER,
                        cpRedunSubDivDescr          DisplayString,
                        cpRedunSubDivImgVersion     DisplayString,
                        cpRedunSubDivImgDBVersion   DisplayString 
                }

        cpRedunSubDivIndex   OBJECT-TYPE
                SYNTAX  INTEGER (1..20)
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Integer ID of each sub division in the ROM.  The order
                         of numbering is from the top of the ROM to the bottom
                         of the ROM."
                ::= { cpRedunSubDivEntry 1 }

        cpRedunSubDivDescr   OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..20))
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Display Name of each Sub Division in ROM"
                ::= { cpRedunSubDivEntry 2 }

        cpRedunSubDivImgVersion    OBJECT-TYPE
                SYNTAX  DisplayString 
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Display Version of each Images in ROM."
                ::= { cpRedunSubDivEntry 3 }

        cpRedunSubDivImgDBVersion  OBJECT-TYPE
                SYNTAX  DisplayString 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Display Database Version of each Images in ROM."
                ::= { cpRedunSubDivEntry  4 }

        cpTimezone      OBJECT-TYPE
                SYNTAX  Timezone
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the internation time zone used by the
                         MPM to determine system time.  The time zone is
                         only used to system time calculations when NTP 
                         is enabled"
                ::= { cp 39 }

        cpNtpState      OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            enabled(1),
                            disabled(2)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Specifies whether NTP support is enabled or
                        disabled."
                ::= { cp 40 }

        cpNtpTimeserver OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the NTP time server queries for updates."
                ::= { cp 41 }

        cpNtpUpdateInterval   OBJECT-TYPE
                SYNTAX  INTEGER (5..1440)
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the NTP time update interval in minutes."
                ::= { cp 42 }

        cpTelnetClient   OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            enable(1),
                            disable(2)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Enable/disable telnet client for active telnet sessions."
                ::= { cp 43 }

        cpLogMask   OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            disabled(1),
                            emerg(2),
                            alert(3),
                            crit(4),
                            err(5),
                            warn(6),
                            notice(7),
                            info(8),
                            debug(9)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Set the log mask.  The masks are equivalent to 
                         syslog priorities."
                ::= { cp 44 }

        cpLogServer1 OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "IP Address of the first log server.  A NULL IP
                         address will remove this entry. Duplicate IP 
                         addresses will be rejected."
                ::= { cp 45 }

        cpLogServer2 OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "IP Address of the first log server.  A NULL IP
                         address will remove this entry. Duplicate IP 
                         addresses will be rejected."
                ::= { cp 46 }

        cpLogServer3 OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "IP Address of the first log server.  A NULL IP
                         address will remove this entry. Duplicate IP 
                         addresses will be rejected."
                ::= { cp 47 }

        cpLogServer4 OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "IP Address of the first log server.  A NULL IP
                         address will remove this entry. Duplicate IP 
                         addresses will be rejected."
                ::= { cp 48 }

        cpLogServer5 OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "IP Address of the first log server.  A NULL IP
                         address will remove this entry. Duplicate IP 
                         addresses will be rejected."
                ::= { cp 49 }

        -- The elements in the cc subgroup of the configuration group

        ccBootPromVer   OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the CC Boot PROM code"
                ::= { cc 1 }

        ccROMSize       OBJECT-TYPE
                SYNTAX  INTEGER (0..1024)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total Size of the CC ROM in Kilobyes"
                ::= { cc 2 }

        ccNumSubDiv     OBJECT-TYPE
                SYNTAX  INTEGER (0..20)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Number of the subdivisions of the ROM."
                ::= { cc 3 }

        ccSubDivTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF CcSubDivEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the number of sub divisions
                         and the size of each subdivision in ROM memory"
                ::= { cc 4 }

        ccSubDivEntry   OBJECT-TYPE
                SYNTAX  CcSubDivEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { ccSubDivIndex }
                ::= { ccSubDivTable 1 }

        CcSubDivEntry   ::=
                SEQUENCE 
                {
                        ccSubDivIndex           INTEGER,
                        ccSubDivDescr           DisplayString,
                        ccSubDivSize            INTEGER,
                        ccSubDivOffset          OCTET STRING
                }

        ccSubDivIndex   OBJECT-TYPE
                SYNTAX  INTEGER (1..20)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Integer ID of each sub division in the ROM.  The order
                         of numbering is from the top of the ROM to the bottom
                         of the ROM."
                ::= { ccSubDivEntry 1 }

        ccSubDivDescr   OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..20))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Display Name of each Sub Division in ROM"
                ::= { ccSubDivEntry 2 }

        ccSubDivSize    OBJECT-TYPE
                SYNTAX  INTEGER (1..1024)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Size of each sub division in ROM in kilobytes"
                ::= { ccSubDivEntry 3 }

        ccSubDivOffset  OBJECT-TYPE
                SYNTAX  OCTET STRING (SIZE (0..8))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Starting address of each sub division in the ROM
                         in HEX notation."
                ::= { ccSubDivEntry 4 }

        ccNumber        OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of CC rows in the following table.  This number
                         is automatically updated whenever a new row is added
                         to the table below."
                ::= { cc 5 }

        ccTable         OBJECT-TYPE
                SYNTAX  SEQUENCE OF CcEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         channel card"
                ::= { cc 6 }

        ccEntry         OBJECT-TYPE
                SYNTAX  CcEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { ccCardLocation, ccCardShelf, ccCardSlot }
                ::= { ccTable 1 }

        CcEntry         ::=
                SEQUENCE 
                {
                        ccCardLocation              CardLocation,
                        ccCardShelf                 CardShelf,
                        ccCardSlot                  INTEGER,
                        ccMfgDate                   DateAndTime,
                        ccSerialNum                 SerialString,
                        ccModelType                 INTEGER,
                        ccName                      CardName,
                        ccFWVersionID               VersionString,
                        ccMfgBiasCurrent            INTEGER,
                        ccMfgModulation             INTEGER,
                        ccMfgApc                    INTEGER,
                        ccMfgIwmModulation          INTEGER,
                        ccMfgRefClock               INTEGER,
                        ccMfgClockDiv               INTEGER,
                        ccBandwidth                 INTEGER,
                        ccSetState                  INTEGER,
                        connMuxChassis              INTEGER,
                        connMuxShelf                INTEGER,
                        connMuxSlot                 INTEGER,
                        connMuxPort                 INTEGER,
                        connDemuxChassis            INTEGER,
                        connDemuxShelf              INTEGER,
                        connDemuxSlot               INTEGER,
                        connDemuxPort               INTEGER,
                        ccModelNum                  DisplayString,
                        ccLinkITUNum                DisplayString,
                        ccLinkWavelength            DisplayString,
                        ccLaserType                 INTEGER,
                        ccRecvDiode                 INTEGER,
                        ccLinkAutoDisable           INTEGER,
                        ccLinkName                  LinkName,
                        ccCsimModule                INTEGER,
                        ccHWName                    CardName,
                        ccBackpackModule            INTEGER,
                        ccBackpackRxITUNumber       DisplayString,
                        ccBackpackTxITUNumber       DisplayString,
                        ccBackpackRxInsertionLoss   DisplayString,
                        ccBackpackTxInsertionLoss   DisplayString,
                        ccBackpackRxExpressLoss     DisplayString,
                        ccBackpackTxExpressLoss     DisplayString,
                        ccSwitchByShelfSlot         DisplayString,
                        ccPathID                    PathIdName,
                        ccCpeDisableThreshold       INTEGER,
                        ccCpeReEnableThreshold      INTEGER,
                        connTxNonMuxDmuxCardType    INTEGER,
                        connTxNonMuxDmuxPort        INTEGER,
                        connTxNonMuxDmuxShelf       INTEGER,
                        connTxNonMuxDmuxSlot        INTEGER,
                        connRxNonMuxDmuxCardType    INTEGER,
                        connRxNonMuxDmuxPort        INTEGER,    
                        connRxNonMuxDmuxShelf       INTEGER,
                        connRxNonMuxDmuxSlot        INTEGER,
                        ccUpsrMode                  INTEGER,
                        ccPairShelf                 INTEGER,
                        ccPairSlot                  INTEGER,
                        ccAdminState                INTEGER,
                        ccRegenPairShelf            INTEGER,
                        ccRegenPairSlot             INTEGER,
                        ccCleiNum                   DisplayString,
                        connCpeTxMcmescShelf        INTEGER,
                        connCpeTxMcmescSlot         INTEGER,
                        connCpeTxMcmescPort         INTEGER,
                        connCpeRxMcmescShelf        INTEGER,
                        connCpeRxMcmescSlot         INTEGER,
                        connCpeRxMcmescPort         INTEGER,
                        ccNumPorts                  INTEGER
                }

        ccCardLocation  OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Location of the card.  Valid values are: Local in
                         the same chassis, or remote to this chassis"
                ::= { ccEntry 1 }

        ccCardShelf     OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2"
                ::= { ccEntry 2 }

        ccCardSlot      OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the module is in.  The range
                         of valid values range from 1 through 17 depending on
                         the chassis type and the shelf the module is in.
                         To delete this card, set this variable to 0."
                ::= { ccEntry 3 }

        ccMfgDate       OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of calibration of the CC card"
                ::= { ccEntry 4 }

        ccSerialNum     OBJECT-TYPE
                SYNTAX  SerialString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Serial # of the CC card."
                ::= { ccEntry 5 }

        ccModelType     OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Model type of the channel card."
                ::= { ccEntry 6 }

        ccName          OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "User configurable name of the channel card"
                ::= { ccEntry 7 }

        ccFWVersionID   OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the CC FW code"
                ::= { ccEntry 8 }

        ccMfgBiasCurrent  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Bias current for the optical laser.  This is the
                         preset manufacturing value"
                ::= { ccEntry 9 }

        ccMfgModulation OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The frequency modulation for the optical laser.  This
                         value is the preset manufacturing value."
                ::= { ccEntry 10 }

        ccMfgApc        OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The APC value.  This value is the preset
                         manufacturing value"
                ::= { ccEntry 11 }

        ccMfgIwmModulation  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The frequency modulation for the IWM channel.  This
                         value is the preset manufacturing value"
                ::= { ccEntry 12 }

        ccMfgRefClock   OBJECT-TYPE
                SYNTAX  INTEGER 
                        {
                                en1660(1),
                                en1944(2),
                                en1953(3)
                        } 
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The value of the reference clock in decimal notation.
                         For a given value, like 1660-EN, the actual value is
                         16.60-EN.  In otherwords, assume a two digit decimal
                         point, plus any appropriate scaling factor.  This
                         value is the preset manufacturing value."
                ::= { ccEntry 13 }

        ccMfgClockDiv   OBJECT-TYPE
                SYNTAX  INTEGER { dout-1250(1), dout-622(2), dout-155(3) }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The clock divisor.  Values are 1250, 622 or 155 in the
                         appropriate clock frequency scale."
                ::= { ccEntry 14 }

        ccBandwidth     OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                                oc3(1),
                                oc12(2),
                                oc48(3),
                                gbEthernet(4),
                                fibreChannel(5),
                                oc192(6),
                                gbE10(9),
                                fibreChannelX2(10)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The bandwidth of the channel card. "
                ::= { ccEntry 15 }

        ccSetState      OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                                other(1),
                                warmboot(2),
                                enableLoopback(3),
                                disableLoopback(4)
                        }                
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Instruct the CC to do a warmboot or loopback.  A get
                         on this will always return an other." 
                ::= { ccEntry 16 }

 

        connMuxChassis  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The connected mux chassis."
                ::= { ccEntry 17 }


        connMuxShelf    OBJECT-TYPE
                SYNTAX  ShelfInput
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The connected mux shelf."
                ::= { ccEntry 18 }

        connMuxSlot     OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The connected mux slot."
                ::= { ccEntry 19 }

        connMuxPort     OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The connected mux port. "
                ::= { ccEntry 20 }

        connDemuxChassis OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The connected demux chassis."
                ::= { ccEntry 21 }

        connDemuxShelf  OBJECT-TYPE
                SYNTAX  ShelfInput
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The connected demux shelf."
                ::= { ccEntry 22 }

        connDemuxSlot   OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The connected demux slot."
                ::= { ccEntry 23 }

        connDemuxPort   OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The connected demux port. " 
                ::= { ccEntry 24 }

        ccModelNum      OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Model number of the CC card. Up to 15 characters"
                ::= { ccEntry 25 }

        ccLinkITUNum    OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Link ITU number of the CC card. Up to 15 characters"
                ::= { ccEntry 26 }

        ccLinkWavelength    OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..15))
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Link Wavelength of the CC card"
                ::= { ccEntry 27 }

        ccLaserType     OBJECT-TYPE
                SYNTAX  INTEGER { uncooled(1), cooled(2)}                
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Laser Type of the Channel Card." 
                ::= { ccEntry 28 }

        ccRecvDiode OBJECT-TYPE
                SYNTAX  INTEGER { apd(1), pin(2)}                
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Receive Diode of the Channel Card." 
                ::= { ccEntry 29 }

        ccLinkAutoDisable   OBJECT-TYPE
                SYNTAX  INTEGER { enable(1), disable(2), enableCpeRxPassThru(3) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Flag to enable/disable the CPE link when the
                         threshold value crosses the lower hysteresis
                         limit.  The default value is disable. CPE disable
                         with CPE Rx pass through is identical to normal
                         CPE disable with the added feature that the remote
                         CPE Tx will be disabled if a loss of light condition
                         is detected on the local CPE Rx."
                ::= { ccEntry 30 }

        ccLinkName      OBJECT-TYPE
                SYNTAX  LinkName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Link name for fiber between the local and the
                         remote cc card."
                ::= { ccEntry 31 }


        ccCsimModule    OBJECT-TYPE
                SYNTAX  INTEGER { installed(1), notinstalled(2), preconfigured(3) }            
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Whether colorSIM module is physically present,
                         not installed or preconfigured."
                ::= { ccEntry 32 }

        ccHWName        OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Display Hardware name of the CC Card."
                ::= { ccEntry 33 }

        ccBackpackModule    OBJECT-TYPE
                SYNTAX  INTEGER { installed(1), notInstalled(2) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Presence of Backpack module, installed or not Installed."
                ::= { ccEntry 34 }

        ccBackpackRxITUNumber       OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Rx ITU number of backpack."
                ::= { ccEntry 35 }

        ccBackpackTxITUNumber       OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Tx ITU number of backpack."
                ::= { ccEntry 36 }

        ccBackpackRxInsertionLoss   OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Rx Insertion loss of backpack."
                ::= { ccEntry 37 }

        ccBackpackTxInsertionLoss   OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Tx Insertion loss of backpack."
                ::= { ccEntry 38 }

        ccBackpackRxExpressLoss     OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Rx Express loss of backpack."
                ::= { ccEntry 39 }

        ccBackpackTxExpressLoss     OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Tx Express loss of backpack."
                ::= { ccEntry 40 }

        ccSwitchByShelfSlot     OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..10))
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Initiate manual UPSR switching by shelf and slot."
                ::= { ccEntry 41 }

        ccPathID        OBJECT-TYPE
                SYNTAX  PathIdName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Upsr Path ID name that this card is associated with.  
                         Set input equal NULL will remove the card off the path 
                         and also remove the path if there is no card left 
                         associate with that path."
                ::= { ccEntry 42 }

        ccCpeDisableThreshold OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "CPE Disable Threshold (Link Rx Power) in dBm.  The limit 
                         is from -32 to -8, but input should be an absolute value 
                         if using mib browser.  A value of 0 in this field indicates
                         that UPSR is not supported. This value will not take affect
                         until ccLinkAutoDisable has been enabled."
                ::= { ccEntry 43 }

        ccCpeReEnableThreshold OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "CPE Re-enable threshold (Link Rx Power) in dBm.  The limit 
                         is from -31 to -7, but input should be an absolute value 
                         if using mib browser.  A value of 0 in this field indicates
                         that UPSR is not supported. This value will not take affect
                         until ccLinkAutoDisable has been enabled."
                ::= { ccEntry 44 }

       connTxNonMuxDmuxCardType      OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Type of module connected to Tx port of OCM."
                ::= { ccEntry 45}

        connTxNonMuxDmuxPort    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Conn port for CC's Tx port.Possible values based on 
                         card types that can connect to OCM are:
                         FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local  Tx
                               4=Local  Rx, 5=Conn B Tx, 6=Conn B Rx
                         OCMU/OCMITU/MCMT1/MCME1/OCM10G/OCM10G: 1=Link Tx, 2=Link Rx 
                         OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN
                         OSAM: 1=IN, 2=OUT
                         W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT
                         W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=15501590/, 4=1570/1610, 5=EXP, 6=IN/OUT
                         UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
                                    4=Link B Rx, 5=Local Tx, 6=Local Rx."
                ::= { ccEntry 46}

        connTxNonMuxDmuxShelf    OBJECT-TYPE
                SYNTAX  ShelfInput
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card conn to Tx port of OCM. Valid values are: 1 to 10."
                ::= { ccEntry 47 }

        connTxNonMuxDmuxSlot     OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card conn to Tx port of OCM."
                ::= { ccEntry 48  }

       connRxNonMuxDmuxCardType      OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Type of module connected to Rx port of OCM."
                ::= { ccEntry 49}

        connRxNonMuxDmuxPort    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Conn port for CC's Rx port.Possible values based on 
                         card types that can connect to OCM are:
                         FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local  Tx
                               4=Local  Rx, 5=Conn B Tx, 6=Conn B Rx
                         OCMU/OCMITU/MCMT1/MCME1/OCM10G/OCM10G: 1=Link Tx, 2=Link Rx 
                         OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN
                         OSAM: 1=IN, 2=OUT
                         W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT
                         W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=15501590/, 4=1570/1610, 5=EXP, 6=IN/OUT
                         UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
                                    4=Link B Rx, 5=Local Tx, 6=Local Rx."
                         
                ::= { ccEntry 50}

        connRxNonMuxDmuxShelf    OBJECT-TYPE
                SYNTAX  ShelfInput
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card conn to Rx port of OCM. Valid values are: 1 to 10."
                ::= { ccEntry 51 }

        connRxNonMuxDmuxSlot     OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card conn to Rx port of OCM."
                ::= { ccEntry 52  }

        ccUpsrMode      OBJECT-TYPE
                SYNTAX  INTEGER {   primary(1), backup(2), na(3) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "UPSR mode for CC card:  primary or backup.	 If not in 
                         upsr configuration, value is na.    This value will not
                         take affect until ccLinkAutoDisable has been enabled."
                ::= { ccEntry 53}

        ccPairShelf     OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The shelf of other CC card in pair."
                ::= { ccEntry 54 }

        ccPairSlot      OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The slot of other CC card in pair.
                         Input 0 to unpair OCMs and delete RSM connections if any."
                ::= { ccEntry 55 }


        ccAdminState    OBJECT-TYPE
                SYNTAX  INTEGER { disable(1), enable(2), na(3) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Administrative control over that cc card. Default value is enable.
                         When disabled, no alarms/events gets
                         generated. For remote CC, the default value is disabled"
                ::= {  ccEntry 56}

        ccRegenPairShelf    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The shelf of other CC card in OCM regeneration pair.    This value 
                        will not take affect until ccLinkAutoDisable has been enabled."
                ::= { ccEntry 57 }

        ccRegenPairSlot OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The slot of other CC card in OCM regeneration pair.
                        Input 0 to unpair OCMs involved.  This value will not take affect
                        until ccLinkAutoDisable has been enabled."
                ::= { ccEntry 58 }

        ccCleiNum       OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CLEI number of the CC Card."
                ::= { ccEntry 59 }

        connCpeTxMcmescShelf   OBJECT-TYPE
                SYNTAX  ShelfInput
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The connected MCMESC shelf."
                ::= { ccEntry 60 }
    
        connCpeTxMcmescSlot   OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The connected MCMESC slot."
                ::= { ccEntry 61 }

        connCpeTxMcmescPort   OBJECT-TYPE
                SYNTAX  INTEGER{ linktx(1), linkrx(2) }        
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The connected MCMESC port. 1=Link Tx, 2=Link Rx."
                ::= { ccEntry 62 }

        connCpeRxMcmescShelf   OBJECT-TYPE
                SYNTAX  ShelfInput
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The connected MCMESC shelf."
                ::= { ccEntry 63 }
    
        connCpeRxMcmescSlot   OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The connected MCMESC slot."
                ::= { ccEntry 64 }

        connCpeRxMcmescPort   OBJECT-TYPE
                SYNTAX  INTEGER { linktx(1), linkrx(2) }        
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The connected MCMESC port. 1=Link Tx, 2=Link Rx."
                ::= { ccEntry 65 }

        ccNumPorts    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total port numbers on each CC card."
                ::= { ccEntry 66 }

        -- The elements in the mux subgroup of the configuration group

        muxBootPromVer  OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the Mux Boot PROM code"
                ::= { mux 1 }

        muxROMSize      OBJECT-TYPE
                SYNTAX  INTEGER (0..1024)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total Size of the ROM in Kilobyes"
                ::= { mux 2 }

        muxNumSubDiv    OBJECT-TYPE
                SYNTAX  INTEGER (0..20)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Number of the subdivisions of the ROM."
                ::= { mux 3 }

        muxSubDivTable  OBJECT-TYPE
                SYNTAX  SEQUENCE OF MuxSubDivEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the number of sub divisions
                         and the size of each subdivision in ROM memory"
                ::= { mux 4 }

        muxSubDivEntry  OBJECT-TYPE
                SYNTAX  MuxSubDivEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { muxSubDivIndex }
                ::= { muxSubDivTable 1 }

        MuxSubDivEntry  ::=
                SEQUENCE 
                {
                        muxSubDivIndex          INTEGER,
                        muxSubDivDescr          DisplayString,
                        muxSubDivSize           INTEGER,
                        muxSubDivOffset         OCTET STRING
                }

        muxSubDivIndex  OBJECT-TYPE
                SYNTAX  INTEGER (0..20)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Integer ID of each sub division in the ROM.  The order
                         of numbering is from the top of the ROM to the bottom
                         of the ROM."
                ::= { muxSubDivEntry 1 }

        muxSubDivDescr  OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..20))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Display Name of each Sub Division in ROM"
                ::= { muxSubDivEntry 2 }

        muxSubDivSize   OBJECT-TYPE
                SYNTAX  INTEGER (0..1024)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Size of each sub division in ROM in kilobytes"
                ::= { muxSubDivEntry 3 }

        muxSubDivOffset OBJECT-TYPE
                SYNTAX  OCTET STRING (SIZE (0..8))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Starting address of each sub division in the ROM
                         in HEX notation."
                ::= { muxSubDivEntry 4 }

        muxNumber       OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of MUX rows in the following table.  This number
                         is automatically updated whenever a new row is added
                         to the table below."
                ::= { mux 5 }

        muxTable        OBJECT-TYPE
                SYNTAX  SEQUENCE OF MuxEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         MUX card"
                ::= { mux 6 }

        muxEntry        OBJECT-TYPE
                SYNTAX  MuxEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { muxCardLocation, muxCardShelf, muxCardSlot }
                ::= { muxTable 1 }

        MuxEntry        ::=
                SEQUENCE 
                {
                        muxCardLocation         CardLocation,
                        muxCardShelf            CardShelf,
                        muxCardSlot             INTEGER,
                        muxModelNum             DisplayString,
                        muxMfgDate              DateAndTime,
                        muxSerialNum            SerialString,
                        muxModelType            INTEGER,
                        muxName                 CardName,
                        muxFWVersionID          VersionString,
                        muxSetState             RebootType,
                        muxNumPorts             INTEGER,
                        muxUpgradeFlag          INTEGER,
                        muxHWName               CardName,
                        muxPathID               PathIdName,
                        muxAdminState           INTEGER,
                        muxCleiNum              DisplayString,
                        muxChannelSpacing       INTEGER,
                        muxStartItu             INTEGER,
                        muxEndItu               INTEGER,
                        muxChannelsPerBand      INTEGER,
                        muxBands                INTEGER
                }

        muxCardLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Location of the module.  Valid values are: Local in
                         the same chassis, or remote to this chassis"
                ::= { muxEntry 1 }

        muxCardShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in."
                ::= { muxEntry 2 }

        muxCardSlot     OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the module is in.  The range
                         of valid values range from 1 through 17 depending on
                         the chassis type and the shelf the module is in.
                         To delete this card, set this variable to 0."
                ::= { muxEntry 3 }

        muxModelNum      OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Model number for module."  
                ::= { muxEntry 4 }

        muxMfgDate      OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of manufacturing of the module"
                ::= { muxEntry 5 }

        muxSerialNum    OBJECT-TYPE
                SYNTAX  SerialString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Serial # of the module."
                ::= { muxEntry 6 }

        muxModelType    OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Model type of the module"
                ::= { muxEntry 7 }

        muxName         OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "User configurable name of the module"
                ::= { muxEntry 8 }

        muxFWVersionID  OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the FW code"
                ::= { muxEntry 9 }

        muxSetState     OBJECT-TYPE
                SYNTAX  RebootType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Instruct the mux to do a warmboot. A get on this will
             always return an other." 
                ::= { muxEntry 10 }


        muxNumPorts    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total port numbers on each MUX card. Should be six"
                ::= { muxEntry 11 }

        muxUpgradeFlag  OBJECT-TYPE
                SYNTAX  INTEGER { upgradable(1), notUpgradable(2) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The MUX card's status is upgradable or not."
                ::= { muxEntry 12 }

        muxHWName       OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Display Hardware name of the mux/dmux Card."
                ::= { muxEntry 13 }

        muxPathID       OBJECT-TYPE
                SYNTAX  PathIdName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Upsr Path ID name that this card is associated with.  
                         Set input equal NULL will remove the card off the path 
                         and also remove the path if there is no card left 
                         associate with that path."
                ::= { muxEntry 14 }

        muxAdminState     OBJECT-TYPE
                SYNTAX  INTEGER { disable(1), enable(2), na(3) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Administrative control over that mux card. Default value is enable.
                         When disabled, no alarms/events gets
                         generated."
                ::= {  muxEntry 15}

        muxCleiNum      OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CLEI number of the mux/dmux Card."
                ::= { muxEntry 16 }

        muxChannelSpacing      OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "ITU channel spacing for the mux/demux card.  Only valid for MD100-40
                         and BD4 Modules."
                ::= { muxEntry 17 }

        muxStartItu      OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "First ITU channel supported by the module.  Only valid for MD100-40
                         and BD4 Modules."
                ::= { muxEntry 18 }

        muxEndItu      OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Last ITU channel supported by the module.  Only valid for MD100-40
                         and BD4 Modules."
                ::= { muxEntry 19 }

        muxChannelsPerBand OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of channels per optical band supported by the module.
                         Only valid for BD-4 and MD100-40 module."
                ::= { muxEntry 20 }

        muxBands        OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of bands supported by the module.  Only valid for
                         BD-4 and MD100-40 module."
                ::= { muxEntry 21 }

        muxPortNumber   OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of MUX's port rows in the following table.  This 
                         number is automatically updated whenever a new row is 
                         added to the table below.Basically a product of
                         # of mux cards and # of ports on each card. Hence it 
                         would have a value of 6, 12, 18 etc.."
                ::= { mux 7 }

        muxPortTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF MuxPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         MUX card's port."
                ::= { mux 8 }

        muxPortEntry    OBJECT-TYPE
                SYNTAX  MuxPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { muxPortCardLocation, muxPortCardShelf, muxPortCardSlot, muxPortIndex }
                ::= { muxPortTable 1 }

        MuxPortEntry    ::=
                SEQUENCE 
                {
                        muxPortCardLocation     CardLocation,
                        muxPortCardShelf        CardShelf,
                        muxPortCardSlot         SlotInput,
                        muxPortIndex            INTEGER,
                        muxWavelength           INTEGER,
                        muxInsertLoss           DisplayString,
                        muxConnCardType         INTEGER,
                        muxConnLocation         CardLocation,
                        muxConnShelf            ShelfInput,
                        muxConnSlot             SlotInput,
                        muxConnPort             INTEGER,
                        muxPortType             INTEGER,
                        muxConnChassisID        DisplayString,
                        muxConnSystemName       DisplayString,
                        muxConnIpAddress        IpAddress,
                        muxPortAvgInsertionLoss DisplayString,
                        muxPortMaxInsertionLoss DisplayString,
                        muxPortTapRatio         DisplayString
                }

        muxPortCardLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Location of the MUX's port.  Valid values are: Local in
                         the same chassis, or remote to this chassis"
                ::= { muxPortEntry 1 }

        muxPortCardShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2."
                ::= { muxPortEntry 2 }

        muxPortCardSlot OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { muxPortEntry 3 }

        muxPortIndex    OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Port's index. Ports 1 through 4 can be use
                         for connection with OCM family or MCMT1/MCME1 only."
                ::= { muxPortEntry 4 }

        muxWavelength   OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port's wavelength: either ITU number or actual
                         wavelength in nm.  Supported by all Mux modules
                         except MD100-40 & BD4."
                ::= { muxPortEntry 5 }

        muxInsertLoss   OBJECT-TYPE
                SYNTAX  DisplayString 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Mux Port insertion Loss range.  Supported by all Mux 
                         modules except MD100-40 & BD4."
                ::= { muxPortEntry 6 }

        muxConnCardType OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Module type connected to mux port.  Supported by all 
                         Mux modules except MD100-40 & BD4."
                ::= { muxPortEntry 7 }

        muxConnLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The chassis's location of the card conn to.  Supported
                         by all Mux modules except MD100-40 & BD4."
                ::= { muxPortEntry 8 }

        muxConnShelf    OBJECT-TYPE
                SYNTAX  ShelfInput
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card conn to. Valid values are: 1 to 2.
                         Supported by all Mux modules except MD100-40 & BD4."
                ::= { muxPortEntry 9 }

        muxConnSlot     OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card conn to. To delete a 
                         connection associated with a specified port, set this 
                         variable to 0.  Supported by all Mux modules except 
                         MD100-40 & BD4."
                ::= { muxPortEntry 10 }

        muxConnPort     OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Conn port for MUX/DMUX's port. Possible values based on 
                         card types that can be connected to are:
                         FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local  Tx
                               4=Local  Rx, 5=Conn B Tx, 6=Conn B Rx
                         OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1/MCMESC: 1=Link Tx, 2=Link Rx 
                         OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN
                         OSAM: 1=IN, 2=OUT
                         W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT
                         W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT
                         UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
                                    4=Link B Rx, 5=Local Tx, 6=Local Rx.
                         Entry supported by all Mux modules except MD100-40 & BD4."
                ::= { muxPortEntry 11 }

        muxPortType     OBJECT-TYPE 
                SYNTAX  INTEGER { mux(1), demux(2) }
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Type of the MUX's port.  Supported by all Mux modules except 
                         MD100-40 & BD4."
                ::= { muxPortEntry 12 }

        muxConnChassisID    OBJECT-TYPE
                SYNTAX  DisplayString(SIZE(0..16))
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Chassis ID of the connected node.  User config. If local connection,
                        a set on it would return an error; would be automatically be set to
                        the chassis Id of the local node.  Supported by all Mux modules except 
                        MD100-40 & BD4."
            ::= { muxPortEntry 13}

        muxConnSystemName   OBJECT-TYPE
                SYNTAX  DisplayString(SIZE(0..32))
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "System Name of the connected node.  User config. If local connection,
                        a set on it would return an error; would be automatically be set to
                        the sysetem name of the local node.  Supported by all Mux modules except
                        MD100-40 & BD4."
                ::= { muxPortEntry 14}

        muxConnIpAddress    OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "IpAddress of the connected node.  User config. If local
                         connection, a set on it would return an error; would be automatically
                         be set to the IP address of the node.  Supported by all Mux modules 
                         except MD100-40 & BD4."
                ::= { muxPortEntry 15}

        muxPortAvgInsertionLoss    OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Average port insertion loss for the port category.  
                         Valid only for MD100-40 & BD4 modules."
                ::= { muxPortEntry 16}

        muxPortMaxInsertionLoss    OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Maximum port insertion loss for the port category.  
                         Valid only for MD100-40 & BD4 modules."
                ::= { muxPortEntry 17}

        muxPortTapRatio    OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Tap ratio for the port category. 
                         Valid only for MD100-40 & BD4 modules."
                ::= { muxPortEntry 18}

        -- The elements in the ps subgroup of the configuration group

        psNumber        OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of PS (power supply) rows in the following table.
                         This number is automatically updated whenever a new row is added
                         to the table below."
                ::= { ps 1 }

        psTable         OBJECT-TYPE
                SYNTAX  SEQUENCE OF PsEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         PS module."
                ::= { ps 2 }

        psEntry OBJECT-TYPE
                SYNTAX  PsEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { psID }
                ::= { psTable 1 }

        PsEntry         ::=
                SEQUENCE 
                {
                        psID                    INTEGER,
                        psMode                  RedundancyMode,
                        psMfgDate               DateAndTime,
                        psSerialNum             SerialString,
                        psModelType             ModelString
                }

        psID    OBJECT-TYPE
                SYNTAX  INTEGER  (1..4)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The module ID the ps module is in.  Valid values are: 1 to 4"
                ::= { psEntry 1 }


        psMode          OBJECT-TYPE
                SYNTAX  RedundancyMode
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Mode of the PS module.  Valid values are: active or
                         standby"
                ::= { psEntry 2 }

        psMfgDate       OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of manufacturing of the PS module."
                ::= { psEntry 3 }

        psSerialNum     OBJECT-TYPE
                SYNTAX  SerialString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Serial # of the PS module. Not Supported Yet."
                ::= { psEntry 4 }

        psModelType     OBJECT-TYPE
                SYNTAX  ModelString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Model type of the PS module. Up to 10 characters.
                         Not Supported Yet."
                ::= { psEntry 5 }

        -- The elements in the download subgroup of the configuration group

        dlFtpTable      OBJECT-TYPE
                SYNTAX  SEQUENCE OF DlFtpEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         FTP server"
                ::= { download 1 }

        dlFtpEntry      OBJECT-TYPE
                SYNTAX  DlFtpEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { dlFtpIp }
                ::= { dlFtpTable 1 }

        DlFtpEntry      ::=
                SEQUENCE 
                {
                        dlFtpIp                 IpAddress,
                        dlFtpLogonID            LogonID,
                        dlFtpPasswd             DisplayString,
                        dlFtpMode               FtpMode,
                        dlFtpPort               INTEGER
                }

        dlFtpIp         OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The IP address of the FTP server."
                ::= { dlFtpEntry 1 }

        dlFtpLogonID    OBJECT-TYPE
                SYNTAX  LogonID
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The FTP user ID for this FTP server.  Up to 15 chars."
                ::= { dlFtpEntry 2 }

        dlFtpPasswd     OBJECT-TYPE
                SYNTAX  DisplayString (SIZE(0..20))
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Password for the above FTP Logon ID.  This password
                         is NOT hashed.  Proper security access is required
                         to set and view this element.  Most FTP connections,
                         however, are using anonymous logon ID with no
                         special password requirements."
                ::= { dlFtpEntry 3 }

        dlFtpMode       OBJECT-TYPE
                SYNTAX  FtpMode
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "FTP server modes.  The choices are: active or passive,
                         active may be necessary for users behind a firewall."
                ::= { dlFtpEntry 4 }

        dlFtpPort       OBJECT-TYPE
                SYNTAX  INTEGER (0..65535)
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "FTP port.  This port is used in conjunction with the
                         FTP IP address for establishing a connection to the FTP
                         server.  Any valid IP port may be entered.  Setting this
                         element to zero (0) will cause the standard FTP port (21)
                         to be used."
                ::= { dlFtpEntry 5 }

        dlPreQualTable  OBJECT-TYPE
                SYNTAX  SEQUENCE OF DlPreQualEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         PreQual table."
                ::= { download 2 }

        dlPreQualEntry  OBJECT-TYPE
                SYNTAX  DlPreQualEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { dlPreQualTypeVersion }
                ::= { dlPreQualTable 1 }

        DlPreQualEntry  ::=
                SEQUENCE 
                {
                        dlPreQualTypeVersion    DisplayString,
                        dlPreQualResult         INTEGER
                }

        
        dlPreQualTypeVersion    OBJECT-TYPE
                SYNTAX  DisplayString (SIZE(0..42))
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The Image type and version to be prequalified 
                         before downloading.  The string format is : 
                         type,version.  The prequal action will be 
                         taken after setting version."
                ::= { dlPreQualEntry 1 }
        
        dlPreQualResult OBJECT-TYPE
                SYNTAX  INTEGER { compatible(1), incompatible(2), unknown-version(3) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The result after comparing type and version of the 
                         selected download image with the compatibility
                         matrix.  The result is either compatible, incompatible 
                         or unknown version.  (Not available at this time).  
                         The default is compatible."  
                ::= { dlPreQualEntry 2 }

        dlDownloadTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF DlDownloadEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for 
                         download and activation."
                ::= { download 3 }

        dlDownloadEntry OBJECT-TYPE
                SYNTAX  DlDownloadEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { dlType, dlLocation, dlShelf, dlSlot }
                ::= { dlDownloadTable 1 }

        DlDownloadEntry ::=
                SEQUENCE 
                {
                        dlType                  DownloadType,
                        dlLocation              DownloadLocation,
                        dlShelf                 DownloadShelf,
                        dlSlot                  DownloadSlot,
                        dlFilename              DisplayString,
                        dlActivate              INTEGER,
                        dlExportType            INTEGER
                }

        dlType          OBJECT-TYPE
                SYNTAX  DownloadType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The Image type to be downloaded or to be activated. The
                         valid values are: all, mpms, boot, macf, mcme1,  
                         mcmesc_code, mcmt1, mpm, ocm, ocm10g, oet, osam, osam_hp/lp, 
                         rsm, upsm, uob.
                         When choosing all, all non-mpm images are downloaded, the 
                         dlLocation should be set to local, dlShelf and dlSlot 
                         should be set to 0, dlFilename should be set to the path 
                         under which all the non-mpm images are put.
                         When choosing mpms, mpm's two associated images, boot and 
                         mpm run code image, are downloaded, the dlLocation should 
                         be set to local, dlShelf and dlSlot should be set to active 
                         mpm's shelf and slot, dlFilename should be set to the path 
                         under which the two images are put.
                         To MCME1/MCMT1 modules, mcm_fpag image will automatically
                         be downloaded when mcme1 or mcmt1 is selected."                    
                ::= { dlDownloadEntry 1 }

        dlLocation      OBJECT-TYPE
                SYNTAX  DownloadLocation
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The location to be downloaded or to be activated.  
                         The choices are:  local, remote or both.  (Only local and 
                         remote are supported at this time, LuxnOS has only local 
                         choice and is not supported yet.
                         When dlType is set to all, only local is supported."
                ::= { dlDownloadEntry 2 }

        dlShelf         OBJECT-TYPE
                SYNTAX  DownloadShelf
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The destination shelf.
                         When dlType is set to all, dlShelf should be set to 0."
                ::= { dlDownloadEntry 3 }

        dlSlot          OBJECT-TYPE
                SYNTAX  DownloadSlot
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the selected shelf.
                         When dlType is set to all, dlSlot should be set to 0."
                ::= { dlDownloadEntry 4 }

        dlFilename      OBJECT-TYPE
                SYNTAX  DisplayString (SIZE(0..255))
                ACCESS  read-write 
                STATUS  mandatory
                DESCRIPTION
                        "The filename and path of the file to be downloaded -up to 255 
                         characters. 
                         When dlType is set to all, the dlFilename field should be set
                         to the path of the directory where the non-mpm images are stored.
                         When dlType is set to mpms, the dlFilename field should be set
                         to the path of the directory where the boot and mpm images are
                         stored.
                         The download action (imageupdate) will be taken after setting 
                         the dlFilename field."
                ::= { dlDownloadEntry 5 }
        
        dlActivate      OBJECT-TYPE
                SYNTAX  INTEGER 
                        { 
                            no(1),
                            activateBackupFirmware(2),
                            activateBackupFPGA(3),
                            activateBackupFirmwareAndFPGA(4),
                            activateForAllLineCards(5)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Activate the backup image at the selected location.
                         To MCMESC, no, activateBackupFirmware, activateBackupFPGA 
                         and activateBackupFirmwareAndFPGA are applicable.
                         To MCMT1/MCME1, no and activateBackupFirmwareAndFPGA are
                         applicable. 
                         To other modules, no and activateBackupFirmware are
                         applicable.
                         When choosing activateForAllLineCards, the dlShelf and dlSlot
                         sholud be set to 0."
                ::= { dlDownloadEntry 6 }

        dlExportType    OBJECT-TYPE
                SYNTAX  INTEGER 
                        { 
                            import(1),
                            export(2)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The image indicated by dlType is to be exported 
                         to the dlFilename using FTP. Ths element is
                         reset to none(1) after each export."
                ::= { dlDownloadEntry 7 }

        dlOSTable       OBJECT-TYPE
                SYNTAX  SEQUENCE OF DlOSEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for 
                         LuxnOS table."
                ::= { download 4 }

        dlOSEntry       OBJECT-TYPE
                SYNTAX  DlOSEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { dlOSIndex }
                ::= { dlOSTable 1 }

        DlOSEntry      ::=
                SEQUENCE
                {
                        dlOSIndex               INTEGER,
                        dlOSVersion             VersionString,
                        dlOSState               OSState,
                        dlOSRelDate             ReleaseDate
                }

        dlOSIndex       OBJECT-TYPE
                SYNTAX  INTEGER (1..2)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The Integer ID for each LuxnOS."
                ::= { dlOSEntry 1 }

        dlOSVersion     OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Display the LuxnOS version."
                ::= { dlOSEntry 2 }

        dlOSState       OBJECT-TYPE
                SYNTAX  OSState
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Display the LuxnOS state: operating(1) is the current 
                         operating LuxnOS, backup(2)is the backup LuxnOS."
                ::= { dlOSEntry 3 }

        dlOSRelDate     OBJECT-TYPE
                SYNTAX  ReleaseDate
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Display the release date of the LuxnOS."
                ::= { dlOSEntry 4 }

        dlUpdateOS      OBJECT-TYPE
                SYNTAX  UpdateOSMode
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Display and select Update LuxnOS Mode: toggle(1) to
                         toggle between operating and backup LuxnOS, revert(2)
                         to copy LuxnOS from the backup to the operating area.
                         The action will be taken after setting UpdateOS ."
                ::= { download 5 }

        -- The elements in the FADM subgroup of the configuration group

        fadmBootPromVer OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the OADM Boot PROM code"
                ::= { fadm 1 }

        fadmROMSize     OBJECT-TYPE
                SYNTAX  INTEGER (1..1024)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total Size of the ROM in Kilobyes"
                ::= { fadm 2 }

        fadmNumSubDiv   OBJECT-TYPE
                SYNTAX  INTEGER (1..20)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Number of the subdivisions of the ROM."
                ::= { fadm 3 }

        fadmSubDivTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF FadmSubDivEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the number of sub divisions
                         and the size of each subdivision in ROM memory"
                ::= { fadm 4 }

        fadmSubDivEntry OBJECT-TYPE
                SYNTAX  FadmSubDivEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { fadmSubDivIndex }
                ::= { fadmSubDivTable 1 }

        FadmSubDivEntry ::=
                SEQUENCE 
                {
                        fadmSubDivIndex         INTEGER,
                        fadmSubDivDescr         DisplayString,
                        fadmSubDivSize          INTEGER,
                        fadmSubDivOffset        OCTET STRING
                }

        fadmSubDivIndex OBJECT-TYPE
                SYNTAX  INTEGER (1..20)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Integer ID of each sub division in the ROM.  The order
                         of numbering is from the top of the ROM to the bottom
                         of the ROM."
                ::= { fadmSubDivEntry 1 }

        fadmSubDivDescr OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..20))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Display Name of each Sub Division in ROM"
                ::= { fadmSubDivEntry 2 }

        fadmSubDivSize  OBJECT-TYPE
                SYNTAX  INTEGER (1..1024)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Size of each sub division in ROM in kilobytes"
                ::= { fadmSubDivEntry 3 }

        fadmSubDivOffset    OBJECT-TYPE
                SYNTAX  OCTET STRING (SIZE (0..8))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Starting address of each sub division in the ROM
                         in HEX notation."
                ::= { fadmSubDivEntry 4 }

        fadmNumber      OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of FADM rows in the following table.  This number
                         is automatically updated whenever a new row is added
                         to the table below."
                ::= { fadm 5 }

        fadmTable       OBJECT-TYPE
                SYNTAX  SEQUENCE OF FadmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         OADM module"
                ::= { fadm 6 }

        fadmEntry       OBJECT-TYPE
                SYNTAX  FadmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { fadmCardLocation, fadmCardShelf, fadmCardSlot }
                ::= { fadmTable 1 }

        FadmEntry       ::=
                SEQUENCE 
                {
                        fadmCardLocation        CardLocation,
                        fadmCardShelf           CardShelf,
                        fadmCardSlot            INTEGER,
                        fadmMfgDate             DateAndTime,
                        fadmSerialNum           SerialString,
                        fadmModelType           INTEGER,
                        fadmName                CardName,
                        fadmFWVersionID         VersionString,
                        fadmSetState            RebootType,
                        fadmNumPorts            INTEGER,
                        fadmUpgradeFlag         INTEGER,
                        fadmModelNum            DisplayString,
                        fadmITUNumber1          INTEGER,
                        fadmITUNumber2          INTEGER,
                        fadmInsertionLoss1      DisplayString,
                        fadmInsertionLoss2      DisplayString,
                        fadmExpressLoss         DisplayString,
                        fadmHWName              CardName,
                        fadmPathID              PathIdName,
                        fadmAdminState          INTEGER,
                        fadmCleiNum             DisplayString,
                        fadmBand                DisplayString,
                        fadmChannelsPerBand     INTEGER,
                        fadmStartItu            INTEGER,
                        fadmEndItu              INTEGER
                }

        fadmCardLocation    OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Location of the FADM Module."
                ::= { fadmEntry 1 }

        fadmCardShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf of the Module is in.  Valid values
                         are: 1, 2 or 3 depending on the chassis type."
                ::= { fadmEntry 2 }

        fadmCardSlot    OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the module is in.  The range
                         of valid values range from 1 through 21 depending on
                         the chassis type and the shelf the module is in.
                         To delete this card, set this variable to 0."
                ::= { fadmEntry 3 }


        fadmMfgDate     OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of manufacturing of the FADM card"
                ::= { fadmEntry 4 }

        fadmSerialNum   OBJECT-TYPE
                SYNTAX  SerialString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Serial # of the FADM card."
                ::= { fadmEntry 5 }

        fadmModelType   OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Model type of the FADM"
                ::= { fadmEntry 6 }

        fadmName        OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Display (Network) name of the FADM Card"
                ::= { fadmEntry 7 }

        fadmFWVersionID OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the FADM FW code"
                ::= { fadmEntry 8 }

        fadmSetState    OBJECT-TYPE
                SYNTAX  RebootType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Instruct the fadm to do a warmboot. A get on this will
                         always return an other." 
                ::= { fadmEntry 9 }


        fadmNumPorts    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total port numbers of FADM module."
                ::= { fadmEntry 10 }

        fadmUpgradeFlag OBJECT-TYPE
                SYNTAX  INTEGER { upgradeable(1), notUpgradeable(2) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The FADM module's status is upgradeable or not."
                ::= { fadmEntry 11 }

        fadmModelNum    OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Model # of the FADM card. Up to 15 characters"
                ::= { fadmEntry 12 }

        fadmITUNumber1  OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port 1's ITU wavelength."
                ::= { fadmEntry 13 }

        fadmITUNumber2  OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        ""
                ::= { fadmEntry 14 }

        fadmInsertionLoss1 OBJECT-TYPE
                SYNTAX  DisplayString 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port 1's insertion loss in dB."
                ::= { fadmEntry 15 }

        fadmInsertionLoss2 OBJECT-TYPE
                SYNTAX  DisplayString 
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        ""
                ::= { fadmEntry 16 }

        fadmExpressLoss OBJECT-TYPE
                SYNTAX  DisplayString 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Internal express port's insertion loss in dB."
                ::= { fadmEntry 17 }

        fadmHWName      OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Display Hardware name of the FADM Card."
                ::= { fadmEntry 18 }

        fadmPathID      OBJECT-TYPE
                SYNTAX  PathIdName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Upsr Path ID name that this card is associated with.  
                         Set input equal NULL will remove the card off the path 
                         and also remove the path if there is no card left 
                         associate with that path."
                ::= { fadmEntry 19 }

       fadmAdminState   OBJECT-TYPE
                SYNTAX  INTEGER { disable(1), enable(2), na(3) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Administrative control over that fadm card. Default value is enable.
                         When disabled, no alarms/events gets
                         generated."
                ::= {  fadmEntry 20}

        fadmCleiNum     OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CLEI number of the fadm Card."
                ::= { fadmEntry 21 }

        fadmBand        OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Optical band supported by the module.  Valid only for 
                         BP-5 and BP-10 modules."
                ::= { fadmEntry 22 }

        fadmChannelsPerBand OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of channels per optical band supported by the module.
                         Only valid for BP-5 and BP-10module."
                ::= { fadmEntry 23 }

        fadmStartItu    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "First ITU channel supported by the module.  Valid only for 
                         BP-5 and BP-10 modules."
                ::= { fadmEntry 24 }

        fadmEndItu    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Last ITU channel supported by the module.  Valid only for 
                         BP-5 and BP-10 modules."
                ::= { fadmEntry 25 }

        fadmPortTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF FadmPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the physical connection for each
                         FADM card's port."
                ::= { fadm 7 }

        fadmPortEntry   OBJECT-TYPE
                SYNTAX  FadmPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { fadmPortCardShelf, fadmPortCardSlot, fadmPortType }
                ::= { fadmPortTable 1 }

        FadmPortEntry   ::=
                SEQUENCE 
                {
                        fadmPortCardShelf       CardShelf,
                        fadmPortCardSlot        SlotInput,
                        fadmPortType            INTEGER,
                        fadmConnLocation        CardLocation,
                        fadmConnIpAddress       IpAddress,
                        fadmConnChassisID       NodeName,
                        fadmConnSystemName      NodeName,                       
                        fadmConnCardType        INTEGER,
                        fadmConnPort            INTEGER,
                        fadmConnShelf           ShelfInput,
                        fadmConnSlot            SlotInput
                }

        fadmPortCardShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2."
                ::= { fadmPortEntry 1 }

        fadmPortCardSlot    OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { fadmPortEntry 2 }

        fadmPortType    OBJECT-TYPE 
                SYNTAX  INTEGER 
                        {
                              connATx-AToD(1),
                              connARx-EXP(2),
                              localTx-Local(3),
                              localRx-Rx(4),
                              connBTx(5),
                              connBRx(6)
                        }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Type of the FADM port.  The order is CLI compatible.
                         For FADM model type, the ports are listed on the left column"
                ::= { fadmPortEntry 3 }

        fadmConnLocation    OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The chassis's location of the card conn to."
                ::= { fadmPortEntry 4 }


        fadmConnIpAddress OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "IpAddress of the connected node.  User config. If local
                         connection, a set on it would return an error; would be automatically
                         be set to the IP address of the node "
                ::= { fadmPortEntry 5}

        fadmConnChassisID   OBJECT-TYPE
                SYNTAX  DisplayString(SIZE(0..16))
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Chassis ID of the connected node.  User config. If local connection,
                         a set on it would return an error; would be automatically be set to
                         the chassis Id of the local node"
                ::= { fadmPortEntry 6}

        fadmConnSystemName OBJECT-TYPE
                SYNTAX  DisplayString(SIZE(0..32))
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "System Name of the connected node.  User config. If local connection,
                         a set on it would return an error; would be automatically be set to
                         the sysetem name of the local node."
                ::= { fadmPortEntry 7}


        fadmConnCardType    OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Module type connected to fadm port."
                ::= { fadmPortEntry 8}

        fadmConnPort    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Conn port for FADM's port. Possible values based on 
                         card types that can be connected to are:
                         FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local  Tx
                               4=Local  Rx, 5=Conn B Tx, 6=Conn B Rx
                         OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1: 1=Link Tx, 2=Link Rx 
                         OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN
                         OSAM: 1=IN, 2=OUT
                         W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT
                         W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT
                         UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
                                    4=Link B Rx, 5=Local Tx, 6=Local Rx."
                ::= { fadmPortEntry 9 }

        fadmConnShelf   OBJECT-TYPE
                SYNTAX  ShelfInput
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card conn to. Valid values are: 1 to 2."
                ::= { fadmPortEntry 10 }

        fadmConnSlot    OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card conn to. To delete a 
                         connection associated with a specified port, set this 
                         variable to 0."
                ::= { fadmPortEntry 11 }
    
        -- The elements in the oppm subgroup of the configuration group

        oppmBootPromVer OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the oppm Boot PROM code"
                ::= { oppm 1 }

        oppmROMSize     OBJECT-TYPE
                SYNTAX  INTEGER (0..1024)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total Size of the ROM in Kilobyes"
                ::= { oppm 2 }

        oppmNumSubDiv   OBJECT-TYPE
                SYNTAX  INTEGER (0..20)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Number of the subdivisions of the ROM."
                ::= { oppm 3 }

        oppmSubDivTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF OppmSubDivEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the number of sub divisions
                         and the size of each subdivision in ROM memory"
                ::= { oppm 4 }

        oppmSubDivEntry OBJECT-TYPE
                SYNTAX  OppmSubDivEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { oppmSubDivIndex }
                ::= { oppmSubDivTable 1 }

        OppmSubDivEntry ::=
                SEQUENCE
                {
                        oppmSubDivIndex         INTEGER,
                        oppmSubDivDescr         DisplayString,
                        oppmSubDivSize          INTEGER,
                        oppmSubDivOffset        OCTET STRING
                }

        oppmSubDivIndex OBJECT-TYPE
                SYNTAX  INTEGER (0..20)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Integer ID of each sub division in the ROM.  The order
                         of numbering is from the top of the ROM to the bottom
                         of the ROM."
                ::= { oppmSubDivEntry 1 }

        oppmSubDivDescr OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..20))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Display Name of each Sub Division in ROM"
                ::= { oppmSubDivEntry 2 }

        oppmSubDivSize  OBJECT-TYPE
                SYNTAX  INTEGER (0..1024)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Size of each sub division in ROM in kilobytes"
                ::= { oppmSubDivEntry 3 }

        oppmSubDivOffset    OBJECT-TYPE
                SYNTAX  OCTET STRING (SIZE (0..8))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Starting address of each sub division in the ROM
                         in HEX notation."
                ::= { oppmSubDivEntry 4 }

        oppmNumber      OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Number of OPPM rows in the following table.  This 
                         number is automatically updated whenever a new row is 
                         added to the table below."
                ::= { oppm 5 }

        oppmTable       OBJECT-TYPE
                SYNTAX  SEQUENCE OF OppmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         OPPM card"
                ::= { oppm 6 }

        oppmEntry       OBJECT-TYPE
                SYNTAX  OppmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { oppmCardLocation, oppmCardShelf, oppmCardSlot }
                ::= { oppmTable 1 }

        OppmEntry       ::=
                SEQUENCE
                {
                        oppmCardLocation        CardLocation,
                        oppmCardShelf           CardShelf,
                        oppmCardSlot            INTEGER,
                        oppmModelNum            DisplayString,
                        oppmMfgDate             DateAndTime,
                        oppmSerialNum           SerialString,
                        oppmModelType           INTEGER,
                        oppmName                CardName,
                        oppmFWVersionID         VersionString,
                        oppmSetState            RebootType,
                        oppmTxInsertLoss        DisplayString,
                        oppmRxInsertLoss        DisplayString,
                        oppmUpgradeFlag         INTEGER,
                        oppmSwitch              INTEGER,
                        oppmMarginForSwitch     INTEGER,
                        oppmHighAlarmMargin     INTEGER,
                        oppmConfigCommit        INTEGER,
                        oppmHWName              CardName,
                        oppmLinkAPathID         PathIdName,
                        oppmLinkBPathID         PathIdName,
                        oppmAdminState          INTEGER,
                        oppmCleiNum             DisplayString,
                        oppmSwitchState         INTEGER
                }

        oppmCardLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Location of the OPPM card.  Valid values are: Local in
                         the same chassis, or remote to this chassis"
                ::= { oppmEntry 1 }

        oppmCardShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2"
                ::= { oppmEntry 2 }

        oppmCardSlot    OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the module is in.  The range
                         of valid values range from 1 through 17 depending on
                         the chassis type and the shelf the module is in.
                         To delete this card, set this variable to 0."
                ::= { oppmEntry 3 }


        oppmModelNum    OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Oppm's model number."
                ::= { oppmEntry 4 }



        oppmMfgDate     OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of manufacturing of the OPPM card"
                ::= { oppmEntry 5 }

        oppmSerialNum   OBJECT-TYPE
                SYNTAX  SerialString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Serial # of the OPPM card."
                ::= { oppmEntry 6 }

        oppmModelType   OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Model type of the OPPM"
                ::= { oppmEntry 7 }

        oppmName        OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Display (Network) name of the OPPM Card"
                ::= { oppmEntry 8 }

        oppmFWVersionID OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the OPPM FW code"
                ::= { oppmEntry 9 }


        oppmSetState    OBJECT-TYPE
                SYNTAX  RebootType
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Instruct the oppm to do a warmboot. A get on this will
                         always return an other." 
                ::= { oppmEntry 10 }

        oppmTxInsertLoss    OBJECT-TYPE
                SYNTAX  DisplayString 
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Transmit insertion loss."
                ::= { oppmEntry 12 }

        oppmRxInsertLoss    OBJECT-TYPE
                SYNTAX  DisplayString 
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        " Receive insertion loss."
                ::= { oppmEntry 13 }

        oppmUpgradeFlag OBJECT-TYPE
                SYNTAX  INTEGER { upgradable(1), notUpgradable(2) }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The oppm card's status is upgradable or not."
                ::= {oppmEntry 14 }

        oppmSwitch     OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            other(1),
                            switchToLinkA(2),
                            switchToLinkB(3),
                            toggle(4),
                            enableAutoSwitch(6)
                        }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "instruct the OPPM to take on an
                         action, such as: switch to link A or link B
                         A get would alway return other(1)."
                ::= { oppmEntry 15 }


        oppmMarginForSwitch OBJECT-TYPE
                SYNTAX  INTEGER (5..15)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Configurable switching margin in dB
                         for protection switch to occur."                         
                ::= { oppmEntry 16 }

        oppmHighAlarmMargin OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "High alarm margin for input signal strength
                         displayed in dB unit "
                ::= { oppmEntry 17 }

        oppmConfigCommit    OBJECT-TYPE
                SYNTAX  INTEGER { other(1), save(2) }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This allows the current module configuration,
                         such as oppmMarginForSwitch, to be
                         stored in permanent storage."
                ::= { oppmEntry 18 }

        oppmHWName      OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Display Hardware name of the OPPM Card."
                ::= { oppmEntry 19 }

        oppmLinkAPathID OBJECT-TYPE
                SYNTAX  PathIdName
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Oppmm LinkA Path ID name that this card is associated with.  
                         Set input equal NULL will remove the card off the path 
                         and also remove the path if there is no card left 
                         associate with that path."
                ::= { oppmEntry 20 }

        oppmLinkBPathID OBJECT-TYPE
                SYNTAX  PathIdName
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Oppm LinkB Path ID name that this card is associated with.  
                         Set input equal NULL will remove the card off the path 
                         and also remove the path if there is no card left 
                         associate with that path."
                ::= { oppmEntry 21 }

       oppmAdminState   OBJECT-TYPE
                SYNTAX  INTEGER { disable(1), enable(2), na(3) }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Administrative control over that oppm card. Default value is enable.
                         When disabled, no alarms/events gets
                         generated."
                ::= { oppmEntry 22 }

        oppmCleiNum     OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "CLEI number of the oppm Card."
                ::= { oppmEntry 23 }

        oppmSwitchState OBJECT-TYPE
                SYNTAX  INTEGER { auto(1), forced(2) }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The switching state. Switching state may be 
                         either auto or forced.  The auto state means
                         automatic switching is enabled.  Forced state 
                         means swithcing is disabled and has been forced
                         to the current active link." 
                ::= { oppmEntry 24 }

        oppmPortTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF OppmPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the physical connection for each
                         OPPM card's port."
                ::= { oppm 7 }

        oppmPortEntry   OBJECT-TYPE
                SYNTAX  OppmPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { oppmPortCardShelf, oppmPortCardSlot, oppmPortType }
                ::= { oppmPortTable 1 }

        OppmPortEntry   ::=
                SEQUENCE
                {
                        oppmPortCardShelf       CardShelf,
                        oppmPortCardSlot        INTEGER,
                        oppmPortType            INTEGER,
                        oppmConnLocation        CardLocation,
                        oppmConnIpAddress       IpAddress,
                        oppmConnChassisID       NodeName,
                        oppmConnSystemName      NodeName,
                        oppmConnCardType        INTEGER,
                        oppmConnPort            INTEGER,
                        oppmConnShelf           INTEGER,
                        oppmConnSlot            INTEGER                     
                        }


        oppmPortCardShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible 
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2."
                ::= { oppmPortEntry 1 }

        oppmPortCardSlot    OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  not-accessible 
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { oppmPortEntry 2 }

        oppmPortType    OBJECT-TYPE 
                SYNTAX  INTEGER
                        {
                              linkATx(1),
                              linkARx(2),
                              linkBTx(3),
                              linkBRx(4),
                              localTx(5),
                              localRx(6)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Type of the OPPM's port."
                ::= { oppmPortEntry 3 }

        oppmConnLocation    OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The chassis's location of the card conn to."
                ::= { oppmPortEntry 4 }


        oppmConnIpAddress   OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "IpAddress of the connected node.  User config. If local
                         connection, a set on it would return an error; would be automatically
                         be set to the IP address of the node "
                ::= { oppmPortEntry 5}

        oppmConnChassisID   OBJECT-TYPE
                SYNTAX  DisplayString(SIZE(0..16))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Chassis ID of the connected node.  User config. If local connection,
                         a set on it would return an error; would be automatically be set to
                         the chassis Id of the local node"
                ::= { oppmPortEntry 6}

        oppmConnSystemName  OBJECT-TYPE
                SYNTAX  DisplayString(SIZE(0..32))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "System Name of the connected node.  User config. If local connection,
                         a set on it would return an error; would be automatically be set to
                         the sysetem name of the local node."
                ::= { oppmPortEntry 7}

        oppmConnCardType    OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Module type connected to oppm port."
                ::= { oppmPortEntry 8}

        oppmConnPort    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Conn port for OPPM's port. Possible values based on 
                         card types that can connect to OPPM are:
                         FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local  Tx
                               4=Local  Rx, 5=Conn B Tx, 6=Conn B Rx
                         OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1: 1=Link Tx, 2=Link Rx 
                         OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN
                         OSAM: 1=IN, 2=OUT
                         W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT
                         W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT
                         UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
                                    4=Link B Rx, 5=Local Tx, 6=Local Rx."
                ::= { oppmPortEntry 9 }

        oppmConnShelf   OBJECT-TYPE
                SYNTAX  ShelfInput
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card conn to. Valid values are: 1 to 2."
                ::= { oppmPortEntry 10 }

        oppmConnSlot    OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card conn to. To delete a 
                         connection associated with a specified port, set this 
                         variable to 0."
                ::= { oppmPortEntry 11 }

        -- The table of mcm, applied to MCMT1 and MCME1


        mcmBootPromVer  OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the mcmt1/mcme1 Boot PROM code"
                ::= { mcm 1 }

        mcmROMSize      OBJECT-TYPE
                SYNTAX  INTEGER (0..1024)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total Size of the ROM in Kilobyes"
                ::= { mcm 2 }

        mcmNumSubDiv    OBJECT-TYPE
                SYNTAX  INTEGER (0..20)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Number of the subdivisions of the ROM."
                ::= { mcm 3 }

        mcmSubDivTable  OBJECT-TYPE
                SYNTAX  SEQUENCE OF McmSubDivEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the number of sub divisions
                         and the size of each subdivision in ROM memory"
                ::= { mcm 4 }

        mcmSubDivEntry  OBJECT-TYPE
                SYNTAX  McmSubDivEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { mcmSubDivIndex }
                ::= { mcmSubDivTable 1 }

        McmSubDivEntry  ::=
                SEQUENCE
                {
                        mcmSubDivIndex          INTEGER,
                        mcmSubDivDescr          DisplayString,
                        mcmSubDivSize           INTEGER,
                        mcmSubDivOffset         OCTET STRING
                }

        mcmSubDivIndex  OBJECT-TYPE
                SYNTAX  INTEGER (0..20)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Integer ID of each sub division in the ROM.  The order
                         of numbering is from the top of the ROM to the bottom
                         of the ROM."
                ::= { mcmSubDivEntry 1 }

        mcmSubDivDescr  OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..20))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Display Name of each Sub Division in ROM"
                ::= { mcmSubDivEntry 2 }

        mcmSubDivSize   OBJECT-TYPE
                SYNTAX  INTEGER (0..1024)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Size of each sub division in ROM in kilobytes"
                ::= { mcmSubDivEntry 3 }

        mcmSubDivOffset OBJECT-TYPE
                SYNTAX  OCTET STRING (SIZE (0..8))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Starting address of each sub division in the ROM
                         in HEX notation."
                ::= { mcmSubDivEntry 4 }

        mcmNumber       OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of ADM rows in the following table.  This number
                         is automatically updated whenever a new row is added
                         to the table below."
                ::= { mcm 5 }

        mcmTable        OBJECT-TYPE
                SYNTAX  SEQUENCE OF McmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         mcmt1/mcme1 module"
                ::= { mcm 6 }

        mcmEntry        OBJECT-TYPE
                SYNTAX  McmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { mcmCardLocation, mcmCardShelf, mcmCardSlot }
                ::= { mcmTable 1 }

        McmEntry        ::=
                SEQUENCE
                {
                        mcmCardLocation         CardLocation,
                        mcmCardShelf            CardShelf,
                        mcmCardSlot             INTEGER,
                        mcmMfgDate              DateAndTime,
                        mcmSerialNum            SerialString,
                        mcmModelType            INTEGER,
                        mcmName                 CardName,
                        mcmFWVersionID          VersionString,
                        mcmAdminState           INTEGER,
                        mcmLaserTemperature     INTEGER,
                        mcmBandwidth            INTEGER,
                        mcmSetState             INTEGER,
                        mcmNumPorts             INTEGER,
                        mcmUpgradeFlag          INTEGER,
                        mcmEthernetStatus       INTEGER,
                        mcmTimingPort           INTEGER,
                        mcmModelNum             DisplayString,
                        mcmMfgBiasCurrent       INTEGER,
                        mcmMfgModulation        INTEGER,
                        mcmMfgApc               INTEGER,
                        mcmMfgIwmModulation     INTEGER,
                        mcmconnMuxShelf         INTEGER,
                        mcmconnMuxSlot          INTEGER,
                        mcmconnMuxPort          INTEGER,
                        mcmconnDemuxShelf       INTEGER,
                        mcmconnDemuxSlot        INTEGER,
                        mcmconnDemuxPort        INTEGER,
                        mcmTimingPriority       DisplayString,
                        mcmLinkName             LinkName,
                        mcmEthernetMode         INTEGER,
                        mcmHWName               CardName,
                        mcmLinkWaveLength       DisplayString,
                        mcmFpgaVersionID        VersionString,
                        mcmPathID               PathIdName,
                        mcmCleiNum              DisplayString,
                        mcmItuNum               DisplayString
                }

        mcmCardLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Location of the mcmt1/mcme1 Module."
                ::= { mcmEntry 1 }

        mcmCardShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf of the mcmt1/mcme1 is in.  Valid values are: 1..2"
                ::= { mcmEntry 2 }

        mcmCardSlot     OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the module is in.  The range
                         of valid values range from 1 through 21 depending on
                         the chassis type and the shelf the module is in.
                         To delete this card, set this variable to 0."
                ::= { mcmEntry 3 }


        mcmMfgDate      OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of calibration of the mcmt1/mcme1 card"
                ::= { mcmEntry 4 }

        mcmSerialNum    OBJECT-TYPE
                SYNTAX  SerialString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Serial # of the mcmt1/mcme1 card."
                ::= { mcmEntry 5 }

        mcmModelType    OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Model type of the mcmt1/mcme1"
                ::= { mcmEntry 6 }

        mcmName         OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Display (Network) name of the MCMT1/MCME1 Module"
                ::= { mcmEntry 7 }

        mcmFWVersionID  OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the MCMT1/MCME1 FW code"
                ::= { mcmEntry 8 }


        mcmAdminState   OBJECT-TYPE
                SYNTAX  INTEGER { disable(1), enable(2), na(3) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Administrative control over that mcmt1/mcme1 card. Default value is enable.
                         When disabled, no alarms/events gets
                         generated."
                ::= {  mcmEntry 9 }

        mcmLaserTemperature  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible 
                STATUS  mandatory
                DESCRIPTION
                        "Temperature of the Laser.  Not yet supported"
                ::= { mcmEntry 10 }

        mcmBandwidth    OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            other(1),
                            oc3(2),
                            oc12(3),
                            oc48(4),
                            gbEthernet(5),
                            fibreChannel(6)
                        }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "mcmt1/mcme1 module's line rate."
                ::= { mcmEntry 11 }


        mcmSetState     OBJECT-TYPE
                SYNTAX  INTEGER 
                        {
                            other(1),
                            resetWithCurrentConfiguration(2),
                            resetWithFactoryDefault(3),
                            nearEndCardLoopback(4),
                            networkCardLoopback(5),
                            nearEndPort1Loopback(6),
                            nearEndPort2Loopback(7),
                            nearEndPort3Loopback(8),
                            nearEndPort4Loopback(9),
                            networkPort1Loopback(10),
                            networkPort2Loopback(11),
                            networkPort3Loopback(12),
                            networkPort4Loopback(13),
                            disableLoopback(14)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Instruct the mcmt1/mcme1 card to do either a reset or loopback.
                         A get on this will always return an other." 
                ::= { mcmEntry 12 }


        mcmNumPorts     OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total port numbers of MCMT1/MCME1 module."
                ::= { mcmEntry 13 }

        mcmUpgradeFlag  OBJECT-TYPE
                SYNTAX  INTEGER { upgradable(1), notUpgradable(2) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The MCMT1/MCME1 module's status is upgradable or not."
                ::= { mcmEntry 14 }

        mcmEthernetStatus    OBJECT-TYPE
                SYNTAX  INTEGER { disabled(1), enabled(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The MCMT1/MCME1 module's Ethernet status is down or up."
                ::= { mcmEntry 15 }

        mcmTimingPort   OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            internal(1),
                            link(2),
                            t1Port1(3),
                            t1Port2(4),
                            t1Port3(5),
                            t1Port4(6)
                        }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The MCMT1/MCME1 module's port clock src"
                ::= { mcmEntry 16 }


        mcmModelNum     OBJECT-TYPE
                SYNTAX  DisplayString 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mcmt1/mcme1 port's model number"
                ::= { mcmEntry 17 }

        mcmMfgBiasCurrent  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Bias current for the optical laser.  This is the
                         preset manufacturing value"
                ::= { mcmEntry 18 }

        mcmMfgModulation    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The frequency modulation for the optical laser.  This
                         value is the preset manufacturing value."
                ::= { mcmEntry 19 }

        mcmMfgApc       OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The APC value.  This value is the preset
                         manufacturing value"
                ::= { mcmEntry 20 }

        mcmMfgIwmModulation  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The frequency modulation for the IWM channel.  This
                         value is the preset manufacturing value"
                ::= { mcmEntry 21 }

       mcmconnMuxShelf  OBJECT-TYPE
                SYNTAX  ShelfInput
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The connected mux shelf."
                ::= { mcmEntry 22 }

        mcmconnMuxSlot  OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The connected mux slot."
                ::= { mcmEntry 23 }

        mcmconnMuxPort  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The connected mux port. "
                ::= { mcmEntry 24 }

    mcmconnDemuxShelf   OBJECT-TYPE
                SYNTAX  ShelfInput
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The connected demux shelf."
                ::= { mcmEntry 25 }

        mcmconnDemuxSlot    OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The connected demux slot."
                ::= { mcmEntry 26 }

        mcmconnDemuxPort    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The connected demux port. " 
                ::= { mcmEntry 27 }

        mcmTimingPriority   OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..12))
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The clock source priority in descending order
                         in the format of a,b,c,d,e,f in which a
                         through f should be replaced with 1 through 6
                         which has the same meaning as the options of
                         mcmTimingPort and are repeated as follows:
                
                            0 - unknown
                            1 - internal
                            2 - link
                            3 - t1Port1
                            4 - t1Port2
                            5 - t1Port3
                            6 - t1Port4

                         For example, '2,5,4,6,3,1' will set the priority
                         of the clock source with link first, followed by
                         t1Port3, followed by t1Port2, followed by t1Port4,
                         followed by t1Port1, followed by internal."
                ::= { mcmEntry 28 }

        mcmLinkName     OBJECT-TYPE
                SYNTAX  LinkName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "User configurable Link name for the connection
                         between the local and remote MCM/MCME1 Modules"
                ::= { mcmEntry 29 }

        mcmEthernetMode OBJECT-TYPE
                SYNTAX  INTEGER { auto(1), forced10M(2), forced100M(3) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "This allows the ethernet mode configured as
                         auto detect, forced 10M, or forced 100M."
                ::= { mcmEntry 30 }

        mcmHWName       OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Display Hardware name of the MCMT1/MCME1 Card."
                ::= { mcmEntry 31 }

        mcmLinkWaveLength   OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..15))
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Link Wavelength of the MCMT1/MCME1 card"
                ::= { mcmEntry 32 }

        mcmFpgaVersionID    OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the MCMT1/MCME1 FPGA."
                ::= { mcmEntry 33 }

        mcmPathID       OBJECT-TYPE
                SYNTAX  PathIdName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Upsr Path ID name that this card is associated with.  
                         Set input equal NULL will remove the card off the path 
                         and also remove the path if there is no card left 
                         associate with that path."
                ::= { mcmEntry 34 }

        mcmCleiNum      OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CLEI number of the mcmt1/mcme1 Card."
                ::= { mcmEntry 35 }

        mcmItuNum       OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "ITU number of the mcmt1/mcme1 Card."
                ::= { mcmEntry 36 }

        mcmPortNumber   OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of MCMT1/MCME1 rows in the following table.  This 
                         number is automatically updated whenever a new row is 
                         added to the table below."
                ::= { mcm 7 }

        mcmPortTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF McmPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         MCMT1/MCME1 module's port."
                ::= { mcm 8 }

        mcmPortEntry    OBJECT-TYPE
                SYNTAX  McmPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { mcmPortCardLocation, mcmPortCardShelf,
                          mcmPortCardSlot,  mcmPortIndex }
                ::= { mcmPortTable 1 }

        McmPortEntry    ::=
                SEQUENCE 
                {
                        mcmPortCardLocation     CardLocation,
                        mcmPortCardShelf        CardShelf,
                        mcmPortCardSlot         INTEGER,
                        mcmPortIndex            INTEGER,
                        mcmPortConnection       INTEGER,
                        mcmPortFraming          INTEGER,
                        mcmPortLineCoding       INTEGER,
                        mcmPortLineEqualizer    INTEGER,
                        mcmPortImpedance        INTEGER
                }

        mcmPortCardLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Location of the MCMT1/MCME1 port.  Valid values are: Local in
                         the same chassis, or remote to this chassis"
                ::= { mcmPortEntry 1 }

        mcmPortCardShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1..2."
                ::= { mcmPortEntry 2 }

        mcmPortCardSlot OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the Module is in.  Valid
                         values are: 1 to 17"
                ::= { mcmPortEntry 3 }

        mcmPortIndex    OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Port's index."
                ::= { mcmPortEntry 4 }

        mcmPortConnection   OBJECT-TYPE
                SYNTAX  INTEGER { disabled(1), enabled(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Port's connection status."
                ::= { mcmPortEntry 5 }

        mcmPortFraming  OBJECT-TYPE
                SYNTAX  INTEGER { esf(1), d4(2), crc4(3) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Type of framing. esf(1) and d4(2) are for mcmt1. crc4(3) is for mcme1.
                         For mcme1, this release of hardware and software only supports fixed 
                         configuration, CRC4, hence, operation of setting will return an
                         error." 
                ::= { mcmPortEntry 6 }

        mcmPortLineCoding    OBJECT-TYPE
                SYNTAX  INTEGER { b8zs(1), ami(2), hdb3(3) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Type of line coding. b8zs(1) and ami(2) are for mcmt1. hdb3(3) is for mcme1. 
                         For mcme1, this release of hardware and software only supports fixed 
                         configuration, HDB3, hence, operation of setting will return an
                         error." 
                ::= { mcmPortEntry 7 }


        mcmPortLineEqualizer     OBJECT-TYPE
                SYNTAX  INTEGER { ft0to133(1), ft133to266(2), ft266to399(3), ft399to533(4), 
                                  ft533to655(5), minus43dB(6) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The Line equilizer. ft0to133(1), ft133to266(2), ft266to399(3), 
                         ft399to533(4), and ft533to655(5) are for mcmt1. minus43dB(6) is for mcme1.
                         For mcme1, this release of hardware and software only supports fixed 
                         configuration, -43dB, hence, operation of setting will return an
                         error." 
                ::= { mcmPortEntry 8 }

        mcmPortImpedance    OBJECT-TYPE
                SYNTAX  INTEGER { ohms-100(1), ohms-75(2), ohms-120(3) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port impedance. ohms-100(1) is for mcmt1. ohms-75(2) and ohms-120(3)
                         are for mcme1. 
                         For mcme1, this release of hardware and software only supports fixed 
                         configuration, 75 ohm, hence, operation of setting will return an
                         error." 
                ::= { mcmPortEntry 9 }

        -- The elements in the fn subgroup of the configuration group

        fnNumber        OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible 
                STATUS  mandatory
                DESCRIPTION
                        "Number of fn rows in the following table.  This number
                         is automatically updated whenever a new row is added
                         to the table below."
                ::= { fn 1 }

        fnTable         OBJECT-TYPE
                SYNTAX  SEQUENCE OF FnEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each fn."
                ::= { fn 2 }

        fnEntry         OBJECT-TYPE
                SYNTAX  FnEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { fnID }
                ::= { fnTable 1 }

        FnEntry         ::=
                SEQUENCE 
                {
                        fnID                    INTEGER,
                        fnMfgDate               DateAndTime,
                        fnSerialNum             SerialString,
                        fnModelType             ModelString
                }

        fnID            OBJECT-TYPE
                SYNTAX  INTEGER  (1..4)
                ACCESS  not-accessible 
                STATUS  mandatory
                DESCRIPTION
                        "The slot ID the fn is in.  Valid values are: 1 to 4"
                ::= { fnEntry 1 }



        fnMfgDate       OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  not-accessible 
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of manufacturing of the fn"
                ::= { fnEntry 2 }

        fnSerialNum     OBJECT-TYPE
                SYNTAX  SerialString
                ACCESS  not-accessible 
                STATUS  mandatory
                DESCRIPTION
                        "Serial # of the fn.  Not Supported Yet."
                ::= { fnEntry 3 }

        fnModelType     OBJECT-TYPE
                SYNTAX  ModelString
                ACCESS  not-accessible 
                STATUS  mandatory
                DESCRIPTION
                        "Model type of the fn. Up to 10 characters.
                         Not Supported Yet."
                ::= { fnEntry 4 }

      --The elements in the csim subgroup of the configuration group

        csimSysMode     OBJECT-TYPE
                SYNTAX  INTEGER { enable(1), disable(2), other(3) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The ColorSim Mode of the Chassis. The value Enable
                         means that the ColorSim feature is enabled for
                         all the interface cards. An action element, returns other on
                         a get request."
                ::= { csim 1 }
        
        csimTable       OBJECT-TYPE
                SYNTAX  SEQUENCE OF CsimEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Each entry in this table represents the
                         information for each colorsim card."
                ::= { csim 2 }

        csimEntry       OBJECT-TYPE
                SYNTAX  CsimEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below."
                INDEX   { csimLocation, csimShelf, csimSlot }
                ::= { csimTable 1 }

        CsimEntry       ::=
                SEQUENCE
                {
                        csimLocation            CardLocation,
                        csimShelf               CardShelf,
                        csimSlot                INTEGER,
                        csimMode                INTEGER,
                        csimDCMode              INTEGER,
                        csimGatingIntvl         INTEGER,
                        csimUpdtIntvl           INTEGER,
                        csimSEIThreshold        DisplayString
                }
    
        csimLocation    OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Location of the card.  Valid values are: Local in
                         the same chassis, or remote to this chassis."
                ::= { csimEntry 1 }

        csimShelf       OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 10"
                ::= { csimEntry 2 }

        csimSlot        OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "This card occupies two slots currently."
                ::= { csimEntry 3 }

        csimMode        OBJECT-TYPE
                SYNTAX  INTEGER { enable(1), disable(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The Mode of ColorSIM for this entry. The Modes
                         are Enable or Disable."
                ::= { csimEntry 4 }

        csimDCMode      OBJECT-TYPE
                SYNTAX  INTEGER { standard(1), continuous(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The Data Collection Mode of ColorSIM."
                ::= { csimEntry 5 }

        csimGatingIntvl OBJECT-TYPE
                SYNTAX  INTEGER (1..65535)
                ACCESS  read-write 
                STATUS  mandatory
                DESCRIPTION
                        "The Gating Interval in seconds in which
                         the incoming data stream is being monitored
                         for errors."
                ::= { csimEntry 6 }

        csimUpdtIntvl   OBJECT-TYPE
                SYNTAX  INTEGER (1..65535)
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Number of gating intervals to be processed before
                         the data is logged for reporting purposes."
                ::= { csimEntry 7 }

        csimSEIThreshold OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The SEI Threshold of ColorSIM specifies the
                         maximum number of errored bits that may have
                         occurred during a single gating interval before
                         the interval is considered Severely Errorred.
                         The Threshold values are in the form of
                         x.ye-z."
                ::= { csimEntry 8 }

        -- The elements in the rpsm subgroup of the configuration group

        rpsmBootPromVer OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the rpsm
             Boot PROM code"
                ::= { rpsm 1 }

        rpsmROMSize     OBJECT-TYPE
                SYNTAX  INTEGER (0..1024)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total Size of the ROM in Kilobyes"
                ::= { rpsm 2 }

        rpsmNumSubDiv   OBJECT-TYPE
                SYNTAX  INTEGER (0..20)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Number of the subdivisions of the ROM."
                ::= { rpsm 3 }

        rpsmSubDivTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF RpsmSubDivEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the number of sub divisions
                         and the size of each subdivision in ROM memory"
                ::= { rpsm 4 }

        rpsmSubDivEntry OBJECT-TYPE
                SYNTAX  RpsmSubDivEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { rpsmSubDivIndex }
                ::= { rpsmSubDivTable 1 }

        RpsmSubDivEntry  ::=
                SEQUENCE
                {
                        rpsmSubDivIndex  INTEGER,
                        rpsmSubDivDescr  DisplayString,
                        rpsmSubDivSize   INTEGER,
                        rpsmSubDivOffset OCTET STRING
                }

        rpsmSubDivIndex OBJECT-TYPE
                SYNTAX  INTEGER (0..20)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Integer ID of each sub division in the ROM.  The order
                         of numbering is from the top of the ROM to the bottom
                         of the ROM."
                ::= { rpsmSubDivEntry 1 }

        rpsmSubDivDescr OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..20))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Display Name of each Sub Division in ROM"
                ::= { rpsmSubDivEntry 2 }

        rpsmSubDivSize  OBJECT-TYPE
                SYNTAX  INTEGER (0..1024)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Size of each sub division in ROM in kilobytes"
                ::= { rpsmSubDivEntry 3 }

        rpsmSubDivOffset OBJECT-TYPE
                SYNTAX  OCTET STRING (SIZE (0..8))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Starting address of each sub division in the ROM
                         in HEX notation."
                ::= { rpsmSubDivEntry 4 }

        rpsmNumber      OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Number of RPSM rows in the following table.  This 
                         number is automatically updated whenever a new row is 
                         added to the table below."
                ::= { rpsm 5 }

        rpsmTable       OBJECT-TYPE
                SYNTAX  SEQUENCE OF RpsmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         RPSM card"
                ::= { rpsm 6 }

        rpsmEntry       OBJECT-TYPE
                SYNTAX  RpsmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { rpsmCardLocation, rpsmCardShelf, rpsmCardSlot }
                ::= { rpsmTable 1 }

        RpsmEntry        ::=
                SEQUENCE
                {
                        rpsmCardLocation        CardLocation,
                        rpsmCardShelf           CardShelf,
                        rpsmCardSlot            INTEGER,
                        rpsmModelNum            DisplayString,
                        rpsmOpticsMfgDate       DateAndTime,
                        rpsmSerialNum           SerialString,
                        rpsmModelType           INTEGER,
                        rpsmHWName              CardName,
                        rpsmFWVersionID         VersionString,
                        rpsmCardName            CardName,
                        rpsmFWName              DisplayString,
                        rpsmFWDate              DateAndTime,
                        rpsmHWVersionID         VersionString,
                        rpsmHWDate              DateAndTime,
                        rpsmSetState            RebootType,
                        rpsmExpressLoss         DisplayString,
                        rpsmMarginForSwitch     INTEGER,
                        rpsmMinProtPowerForSwitch   INTEGER,
                        rpsmDeBounce            INTEGER,
                        rpsmBlackOutTime        INTEGER,
                        rpsmSwitch              INTEGER,
                        rpsmAddDropLoss         DisplayString,
                        rpsmPathID              PathIdName,
                        rpsmAdminState          INTEGER
                }

        rpsmCardLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Location of the RPSM card.  Valid values are: Local in
                         the same chassis, or remote to this chassis."
                ::= { rpsmEntry 1 }

        rpsmCardShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2."
                ::= { rpsmEntry 2 }

        rpsmCardSlot    OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the module is in.  The range
                         of valid values range from 1 through 17 depending on
                         the chassis type and the shelf the module is in.
                         To delete this card, set this variable to 0."
                ::= { rpsmEntry 3 }

        rpsmModelNum    OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "RPSM's model number."
                ::= { rpsmEntry 4 }

        rpsmOpticsMfgDate OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of manufacturing of the optics
                         on the RPSM card."
                ::= { rpsmEntry 5 }

        rpsmSerialNum   OBJECT-TYPE
                SYNTAX  SerialString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Serial # of the RPSM card."
                ::= { rpsmEntry 6 }

        rpsmModelType   OBJECT-TYPE
                SYNTAX  INTEGER { rpsm(17) }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Model type of the RPSM."
                ::= { rpsmEntry 7 }

        rpsmHWName      OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Manufacturing Hardware name of the RPSM Card."
                ::= { rpsmEntry 8 }

        rpsmFWVersionID OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the RPSM FW code"
                ::= { rpsmEntry 9 }

        rpsmCardName    OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "User configurable card name." 
                ::= { rpsmEntry 10 }

        rpsmFWName      OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "RPSM's Firmware Name."
                ::= { rpsmEntry 11 }

        rpsmFWDate      OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of latest Firmware of the RPSM card."
                ::= { rpsmEntry 12 }

        rpsmHWVersionID OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the RPSM HW code."
                ::= { rpsmEntry 13 }

        rpsmHWDate      OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of Hardware of the RPSM card."
                ::= { rpsmEntry 14 }

        rpsmSetState    OBJECT-TYPE
                SYNTAX  RebootType
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Instruct the rpsm to do a warmboot. A get on this will
             always return an other." 
                ::= { rpsmEntry 15 }

        rpsmExpressLoss  OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Insertion loss for the expressed channel
             through the RPSM module in dB." 
                ::= { rpsmEntry 16 }

        rpsmMarginForSwitch  OBJECT-TYPE
                SYNTAX  INTEGER (-40..0)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Switching threshold in dB for protection
             switch to occur." 
                ::= { rpsmEntry 17 }

        rpsmMinProtPowerForSwitch     OBJECT-TYPE
                SYNTAX  INTEGER (-40..0)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Minimum protection link's light power in dBm
             to allow protection switching to occur." 
                ::= { rpsmEntry 18 }

        rpsmDeBounce    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Debounce in number of times to measure
                         low light power before protection switch."
                ::= { rpsmEntry 19 }

        rpsmBlackOutTime OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Black out time in unit of 0.1 second after
                         protection switch to allow another protection
                         switch to occur again." 
                ::= { rpsmEntry 20 }

        rpsmSwitch      OBJECT-TYPE
                SYNTAX  INTEGER
                        { 
                            other(1),
                            switchToLinkA(2),
                            switchToLinkB(3), 
                            toggle(4),
                            enableAutoSwitch(6) 
                        }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "instruct the RPSM to take on an action,
                         such as: switch to link A or link B.
                         A get would alway return other(1)."
                ::= { rpsmEntry 21 }

        rpsmAddDropLoss OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Insertion loss of the Add/Drop path
             through the RPSM module in dB." 
                ::= { rpsmEntry 22 }

        rpsmPathID      OBJECT-TYPE
                SYNTAX  PathIdName
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Upsr Path ID name that this card is associated with.  
                         Set input equal NULL will remove the card off the path 
                         and also remove the path if there is no card left 
                         associate with that path." 
                ::= { rpsmEntry 23 }

        rpsmAdminState  OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            disable(1),
                            enable(2),
                            na(3)
                        }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Administrative control over that rpsm card. Default value is enable.
                         When disabled, no alarms/events gets
                         generated."
                ::= { rpsmEntry 24}

        rpsmPortTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF RpsmPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the physical connection for each
                         RPSM card's port."
                ::= { rpsm 7 }

        rpsmPortEntry   OBJECT-TYPE
                SYNTAX  RpsmPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { rpsmPortCardShelf, rpsmPortCardSlot, rpsmPortType }
                ::= { rpsmPortTable 1 }

        RpsmPortEntry        ::=
                SEQUENCE 
                {
                        rpsmPortCardShelf       CardShelf,
                        rpsmPortCardSlot        SlotInput,
                        rpsmPortType            INTEGER,
                        rpsmConnCardType        INTEGER,
                        rpsmConnPort            INTEGER,
                        rpsmConnShelf           ShelfInput,
                        rpsmConnSlot            SlotInput                       
                }

        rpsmPortCardShelf OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2."
                ::= { rpsmPortEntry 1 }

        rpsmPortCardSlot OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { rpsmPortEntry 2 }

        rpsmPortType        OBJECT-TYPE 
                SYNTAX  INTEGER 
                        {
                            linkEast(1), 
                            linkWest(2), 
                            in(3),
                            out(4), 
                            aTOd(5), 
                            exp(6) 
                        }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Type of the RPSM's port.  The order is CLI compatible."
                ::= { rpsmPortEntry 3 }

        rpsmConnCardType OBJECT-TYPE
                SYNTAX  INTEGER (0..30)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Type of connection.  Valid values are ocmu(2),
                         ocmItu(3), mux(4), demux(5), mcm(8), w4cd(10), w2cmd(13), w4cm(21),
                         osam(20), fadm(6), oppm(7), fadmb(19), ocme(24), etc...
                         A zero will be used for no connections."
                ::= { rpsmPortEntry 4}

        rpsmConnPort    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Conn port for RPSM's port.Possible values based on 
                         card types that can connect to RPSM are:
                         OFCM/OFCD: 1/2/3/4= port index, 5=EXP, 6=OUT/IN
                         W4CM/W4CD: 1=1510, 2=1530, 3=1550,
                                            4=1570, 5=EXP, 6=IN/OUT
                         W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT
                         OSAM: 1=IN, 2=OUT
                         FADM: 1=Conn A Tx, 2=Conn A Rx,  3=Local  Tx
                             4=Local  Rx, 5=Conn B Tx, 6=Conn B Rx
                         FADMB: 1=A/D, 2=EXP, 3=Local, 4=Rx
                         OCMU/OCMITU/MCM: 1=Link Tx, 2=Link Rx
                         UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
                         4=Link B Rx, 5=Local Tx, 6=Local Rx "
                ::= { rpsmPortEntry 5 }

        rpsmConnShelf   OBJECT-TYPE
                SYNTAX  ShelfInput
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card conn to. Valid values are: 1 to 2."
                ::= { rpsmPortEntry 6 }

        rpsmConnSlot    OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card conn to."
                ::= { rpsmPortEntry 7 }

        -- The elements in the rsdm subgroup of the configuration group

        rsdmBootPromVer OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the rsdm Boot PROM code"
                ::= { rsdm 1 }

        rsdmROMSize     OBJECT-TYPE
                SYNTAX  INTEGER (0..1024)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total Size of the ROM in Kilobyes"
                ::= { rsdm 2 }

        rsdmNumSubDiv   OBJECT-TYPE
                SYNTAX  INTEGER (0..20)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Number of the subdivisions of the ROM."
                ::= { rsdm 3 }

        rsdmSubDivTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF RsdmSubDivEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the number of sub divisions
                         and the size of each subdivision in ROM memory"
                ::= { rsdm 4 }

        rsdmSubDivEntry OBJECT-TYPE
                SYNTAX  RsdmSubDivEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { rsdmSubDivIndex }
                ::= { rsdmSubDivTable 1 }

        RsdmSubDivEntry  ::=
                SEQUENCE
                {
                        rsdmSubDivIndex  INTEGER,
                        rsdmSubDivDescr  DisplayString,
                        rsdmSubDivSize   INTEGER,
                        rsdmSubDivOffset OCTET STRING
                }

        rsdmSubDivIndex OBJECT-TYPE
                SYNTAX  INTEGER (0..20)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Integer ID of each sub division in the ROM.  The order
                         of numbering is from the top of the ROM to the bottom
                         of the ROM."
                ::= { rsdmSubDivEntry 1 }

        rsdmSubDivDescr OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..20))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Display Name of each Sub Division in ROM"
                ::= { rsdmSubDivEntry 2 }

        rsdmSubDivSize  OBJECT-TYPE
                SYNTAX  INTEGER (0..1024)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Size of each sub division in ROM in kilobytes"
                ::= { rsdmSubDivEntry 3 }

        rsdmSubDivOffset OBJECT-TYPE
                SYNTAX  OCTET STRING (SIZE (0..8))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Starting address of each sub division in the ROM
                         in HEX notation."
                ::= { rsdmSubDivEntry 4 }

        rsdmNumber      OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Number of RSDM rows in the following table.  This 
                         number is automatically updated whenever a new row is 
                         added to the table below."
                ::= { rsdm 5 }

        rsdmTable       OBJECT-TYPE
                SYNTAX  SEQUENCE OF RsdmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         RSDM card"
                ::= { rsdm 6 }

        rsdmEntry       OBJECT-TYPE
                SYNTAX  RsdmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { rsdmCardLocation, rsdmCardShelf, rsdmCardSlot }
                ::= { rsdmTable 1 }

        RsdmEntry        ::=
                SEQUENCE
                {
                        rsdmCardLocation            CardLocation,
                        rsdmCardShelf               CardShelf,
                        rsdmCardSlot                INTEGER,
                        rsdmModelNum                DisplayString,
                        rsdmOpticsMfgDate           DateAndTime,
                        rsdmSerialNum               SerialString,
                        rsdmModelType               INTEGER,
                        rsdmHWName                  CardName,
                        rsdmCardName                CardName,
                        rsdmFWVersionID             VersionString,
                        rsdmFWName                  DisplayString,
                        rsdmFWDate                  DateAndTime,
                        rsdmHWVersionID             VersionString,
                        rsdmHWDate                  DateAndTime,
                        rsdmSetState                RebootType,
                        rsdmRxITUNumber             INTEGER,
                        rsdmTxITUNumber             INTEGER,
                        rsdmRxInsertionLoss         DisplayString,
                        rsdmTxInsertionLoss         DisplayString, 
                        rsdmExpressLoss             DisplayString,
                        rsdmMarginForSwitch         INTEGER,
                        rsdmMinProtPowerForSwitch   INTEGER,
                        rsdmDeBounce                INTEGER,
                        rsdmBlackOutTime            INTEGER,
                        rsdmSwitch                  INTEGER,
                        rsdmPathID                  PathIdName,
                        rsdmAdminState              INTEGER
                }

        rsdmCardLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Location of the RSDM card.  Valid values are: Local in
                         the same chassis, or remote to this chassis."
                ::= { rsdmEntry 1 }

        rsdmCardShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2"
                ::= { rsdmEntry 2 }

        rsdmCardSlot    OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the module is in.  The range
                         of valid values range from 1 through 17 depending on
                         the chassis type and the shelf the module is in.
                         To delete this card, set this variable to 0."
                ::= { rsdmEntry 3 }

        rsdmModelNum    OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "RSDM's model number."
                ::= { rsdmEntry 4 }

        rsdmOpticsMfgDate OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of manufacturing of the optics on
                         the RSDM card."
                ::= { rsdmEntry 5 }

        rsdmSerialNum   OBJECT-TYPE
                SYNTAX  SerialString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Serial # of the RSDM card."
                ::= { rsdmEntry 6 }

        rsdmModelType   OBJECT-TYPE
                SYNTAX  INTEGER { rsdm(16) }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Model type of the RSDM."
                ::= { rsdmEntry 7 }

        rsdmHWName      OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Display Hardware name of the RSDM Card."
                ::= { rsdmEntry 8 }

        rsdmCardName    OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "User configurable name of the RSDM Card."
                ::= { rsdmEntry 9 }

        rsdmFWVersionID OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the RSDM FW code"
                ::= { rsdmEntry 10 }

        rsdmFWName      OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "RSDM's Firmware Name."
                ::= { rsdmEntry 11 }

        rsdmFWDate      OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of latest Firmware of the RSDM card."
                ::= { rsdmEntry 12 }

        rsdmHWVersionID OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the RSDM HW code."
                ::= { rsdmEntry 13 }

        rsdmHWDate      OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of Hardware of the RSDM card."
                ::= { rsdmEntry 14 }

        rsdmSetState    OBJECT-TYPE
                SYNTAX  RebootType
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Instruct the rsdm to do a warmboot. A get on this will
                         always return an other." 
                ::= { rsdmEntry 15 }

        rsdmRxITUNumber OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Receive port's ITU wavelength number."
                ::= { rsdmEntry 16 }

        rsdmTxITUNumber OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Transmit port's ITU wavelength number."
                ::= { rsdmEntry 17 }

        rsdmRxInsertionLoss OBJECT-TYPE
                SYNTAX  DisplayString 
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Receive port's insertion loss in dB."
                ::= { rsdmEntry 18 }

        rsdmTxInsertionLoss OBJECT-TYPE
                SYNTAX  DisplayString 
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Transmit port's insertion loss in dB."
                ::= { rsdmEntry 19 }

        rsdmExpressLoss OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Insertion loss for the expressed channel
                         through the RSDM module in dB." 
                ::= { rsdmEntry 20 }

        rsdmMarginForSwitch OBJECT-TYPE
                SYNTAX  INTEGER (-40..0)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Switching threshold in dB for protection
                         switch to occur." 
                ::= { rsdmEntry 21 }

        rsdmMinProtPowerForSwitch OBJECT-TYPE
                SYNTAX  INTEGER (-40..0)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Minimum protection link's light power in dBm
             to allow protection switching to occur." 
                ::= { rsdmEntry 22 }

        rsdmDeBounce    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Debounce in number of times to measure
                         low light power before protection switch."
                ::= { rsdmEntry 23 }

        rsdmBlackOutTime OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Black out time in unit of 0.1 second after
                         protection switch to allow another protection
                         switch to occur again." 
                ::= { rsdmEntry 24 }

        rsdmSwitch      OBJECT-TYPE
                SYNTAX  INTEGER 
                        { 
                            other(1),
                            switchToLinkA(2),
                            switchToLinkB(3), 
                            toggle(4),
                            enableAutoSwitch(6) 
                        }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Instruct the RSDM to take on an action,
                         such as: switch to link A or link B.
                         A snmp get would always return other(1)."
                ::= { rsdmEntry 25 }

        rsdmPathID      OBJECT-TYPE
                SYNTAX  PathIdName
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Upsr Path ID name that this card is associated with.  
                         Set input equal NULL will remove the card off the path 
                         and also remove the path if there is no card left 
                         associate with that path." 
                ::= { rsdmEntry 26 }


        rsdmAdminState   OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            disable(1),
                            enable(2),
                            na(3)
                        }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Administrative control over that rsdm card. Default value is enable.
                         When disabled, no alarms/events gets
                         generated."
                ::= { rsdmEntry 27 }

        rsdmPortTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF RsdmPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the physical connection for each
                         RSDM card's port."
                ::= { rsdm 7 }

        rsdmPortEntry   OBJECT-TYPE
                SYNTAX  RsdmPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { rsdmPortCardShelf, rsdmPortCardSlot, rsdmPortType }
                ::= { rsdmPortTable 1 }

        RsdmPortEntry        ::=
                SEQUENCE 
                {
                        rsdmPortCardShelf       CardShelf,
                        rsdmPortCardSlot        SlotInput,
                        rsdmPortType            INTEGER,
                        rsdmConnCardType        CardType,
                        rsdmConnPort            INTEGER,
                        rsdmConnShelf           ShelfInput,
                        rsdmConnSlot            SlotInput                       
                }

        rsdmPortCardShelf OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2."
                ::= { rsdmPortEntry 1 }

        rsdmPortCardSlot OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { rsdmPortEntry 2 }

        rsdmPortType    OBJECT-TYPE 
                SYNTAX  INTEGER
                        { 
                            linkEast(1), 
                            linkWest(2), 
                            linkRx(3),
                            linkTx(4) 
                        }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Type of the RSDM's port.  The order is CLI compatible."
                ::= { rsdmPortEntry 3 }

        rsdmConnCardType      OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Type of connection.  Valid values are ocmu(2),
                         ocmItu(3), mux(4), demux(5), mcm(8), w4cd(10), w2cmd(13), w4cm(21),
                         osam(20), fadm(6), oppm(7), fadmb(19), ocme(24), etc...
                         A zero will be used for no connections."
                ::= { rsdmPortEntry 4}

        rsdmConnPort    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Conn port for RSDM's port.Possible values based on 
                         card types that can connect to RSDM are:
                         OFCM/OFCD: 1/2/3/4= port index, 5=EXP, 6=OUT/IN
                         W4CM/W4CD: 1=1510, 2=1530, 3=1550,
                                            4=1570, 5=EXP, 6=IN/OUT
                         W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT
                         OSAM: 1=IN, 2=OUT
                         FADM: 1=Conn A Tx, 2=Conn A Rx,  3=Local  Tx
                             4=Local  Rx, 5=Conn B Tx, 6=Conn B Rx
                         FADMB: 1=A/D, 2=EXP, 3=Local, 4=Rx
                         OCMU/OCMITU/MCM: 1=Link Tx, 2=Link Rx 
                         UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
                         4=Link B Rx, 5=Local Tx, 6=Local Rx "
                ::= { rsdmPortEntry 5 }

        rsdmConnShelf   OBJECT-TYPE
                SYNTAX  ShelfInput
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card conn to. Valid values are: 1 to 2."
                ::= { rsdmPortEntry 6 }

        rsdmConnSlot    OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card conn to."
                ::= { rsdmPortEntry 7 }


        -- The elements in the rtdm subgroup of the configuration group

        rtdmBootPromVer OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the RTDM Boot PROM code"
                ::= { rtdm 1 }

        rtdmROMSize     OBJECT-TYPE
                SYNTAX  INTEGER (0..1024)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total Size of the ROM in Kilobyes"
                ::= { rtdm 2 }

        rtdmNumSubDiv   OBJECT-TYPE
                SYNTAX  INTEGER (0..20)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Number of the subdivisions of the ROM."
                ::= { rtdm 3 }

        rtdmSubDivTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF RtdmSubDivEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the number of sub divisions
                         and the size of each subdivision in ROM memory"
                ::= { rtdm 4 }

        rtdmSubDivEntry OBJECT-TYPE
                SYNTAX  RtdmSubDivEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { rtdmSubDivIndex }
                ::= { rtdmSubDivTable 1 }

        RtdmSubDivEntry  ::=
                SEQUENCE
                {
                        rtdmSubDivIndex  INTEGER,
                        rtdmSubDivDescr  DisplayString,
                        rtdmSubDivSize   INTEGER,
                        rtdmSubDivOffset OCTET STRING
                }

        rtdmSubDivIndex OBJECT-TYPE
                SYNTAX  INTEGER (0..20)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Integer ID of each sub division in the ROM.  The order
                         of numbering is from the top of the ROM to the bottom
                         of the ROM."
                ::= { rtdmSubDivEntry 1 }

        rtdmSubDivDescr OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..20))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Display Name of each Sub Division in ROM"
                ::= { rtdmSubDivEntry 2 }

        rtdmSubDivSize  OBJECT-TYPE
                SYNTAX  INTEGER (0..1024)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Size of each sub division in ROM in kilobytes"
                ::= { rtdmSubDivEntry 3 }

        rtdmSubDivOffset OBJECT-TYPE
                SYNTAX  OCTET STRING (SIZE (0..8))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Starting address of each sub division in the ROM
                         in HEX notation."
                ::= { rtdmSubDivEntry 4 }

        rtdmNumber      OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Number of RTDM rows in the following table.  This number
                         is automatically updated whenever a new row is added
                         to the table below."
                ::= { rtdm 5 }

        rtdmTable       OBJECT-TYPE
                SYNTAX  SEQUENCE OF RtdmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         RTDM card"
                ::= { rtdm 6 }

        rtdmEntry       OBJECT-TYPE
                SYNTAX  RtdmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { rtdmCardLocation, rtdmCardShelf, rtdmCardSlot }
                ::= { rtdmTable 1 }

        RtdmEntry        ::=
                SEQUENCE
                {
                    rtdmCardLocation            CardLocation,
                    rtdmCardShelf               CardShelf,
                    rtdmCardSlot                INTEGER,
                    rtdmModelNum                DisplayString,
                    rtdmOpticsMfgDate           DateAndTime,
                    rtdmSerialNum               SerialString,
                    rtdmModelType               INTEGER,
                    rtdmHWName                  CardName,
                    rtdmFWVersionID             VersionString,
                    rtdmCardName                CardName,
                    rtdmFWName                  DisplayString,
                    rtdmFWDate                  DateAndTime,
                    rtdmHWVersionID             VersionString,
                    rtdmHWDate                  DateAndTime,
                    rtdmSetState                RebootType,
                    rtdmCommonEInsertionLoss    DisplayString,
                    rtdmCommonWInsertionLoss    DisplayString,
                    rtdmMonEastInsertionLoss    DisplayString,
                    rtdmMonWestInsertionLoss    DisplayString,
                    rtdmPathID                  PathIdName,
                    rtdmAdminState              INTEGER
                }

        rtdmCardLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Location of the RTDM card.  Valid values are: Local in
                         the same chassis, or remote to this chassis"
                ::= { rtdmEntry 1 }

        rtdmCardShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 10"
                ::= { rtdmEntry 2 }

        rtdmCardSlot    OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the module is in.  The range
             of valid values range from 1 through 17 depending on
             the chassis type and the shelf the module is in.
                         To delete this card, set this variable to 0."
                ::= { rtdmEntry 3 }

        rtdmModelNum    OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Model number for RTDM."  
                ::= { rtdmEntry 4 }

        rtdmOpticsMfgDate OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of manufacturing of the optics
             on the RTDM card"
                ::= { rtdmEntry 5 }

        rtdmSerialNum   OBJECT-TYPE
                SYNTAX  SerialString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Serial # of the RTDM card."
                ::= { rtdmEntry 6 }

        rtdmModelType   OBJECT-TYPE
                SYNTAX  INTEGER { rtdm(18) }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Model type of the RTDM"
                ::= { rtdmEntry 7 }

        rtdmHWName      OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Display (Network) name of the RTDM Card"
                ::= { rtdmEntry 8 }

    rtdmFWVersionID     OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the RTDM FW code"
                ::= { rtdmEntry 9 }

    rtdmCardName        OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "User configurable card name." 
                ::= { rtdmEntry 10 }

    rtdmFWName          OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "RTDM's Firmware Name."
                ::= { rtdmEntry 11 }

        rtdmFWDate      OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of latest Firmware of the RTDM card"
                ::= { rtdmEntry 12 }

        rtdmHWVersionID OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the RTDM HW code"
                ::= { rtdmEntry 13 }

        rtdmHWDate      OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of Hardware of the RTDM card"
                ::= { rtdmEntry 14 }

        rtdmSetState    OBJECT-TYPE
                SYNTAX  RebootType
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Instruct the rtdm to do a warmboot. A get on this will
             always return an other." 
                ::= { rtdmEntry 15 }

        rtdmCommonEInsertionLoss  OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The RTDM Common path East's insertion loss in dB."
                ::= { rtdmEntry 16 }

        rtdmCommonWInsertionLoss  OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The RTDM Common path West's insertion loss in dB."
                ::= { rtdmEntry 17 }

        rtdmMonEastInsertionLoss    OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The RTDM Monitor East Path's insertion loss
                         in dB."
                ::= { rtdmEntry 18 }

        rtdmMonWestInsertionLoss    OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The RTDM Monitor West Path's insertion loss
                         in dB."
                ::= { rtdmEntry 19 }

        rtdmPathID      OBJECT-TYPE
                SYNTAX  PathIdName
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Upsr Path ID name that this card is associated with.  
                         Set input equal NULL will remove the card off the path 
                         and also remove the path if there is no card left 
                         associate with that path."
                ::= { rtdmEntry 20 }

        rtdmAdminState     OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            disable(1),
                            enable(2),
                            na(3)
                        }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Administrative control over that rtdm card. Default value is enable.
                         When disabled, no alarms/events gets
                         generated."
                ::= { rtdmEntry 21 }

        rtdmPortTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF RtdmPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the physical connection for each
                         RTDM card's port."
                ::= { rtdm 7 }

        rtdmPortEntry   OBJECT-TYPE
                SYNTAX  RtdmPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { rtdmPortCardShelf, rtdmPortCardSlot, rtdmPortType }
                ::= { rtdmPortTable 1 }

        RtdmPortEntry        ::=
                SEQUENCE 
                {
                        rtdmPortCardShelf       CardShelf,
                        rtdmPortCardSlot        SlotInput,
                        rtdmPortType            INTEGER,
                        rtdmConnCardType        INTEGER,
                        rtdmConnPort            INTEGER,
                        rtdmConnShelf           ShelfInput,
                        rtdmConnSlot            SlotInput                       
                }

        rtdmPortCardShelf OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2."
                ::= { rtdmPortEntry 1 }

        rtdmPortCardSlot OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { rtdmPortEntry 2 }

        rtdmPortType    OBJECT-TYPE 
                SYNTAX  INTEGER
                        { 
                            localRx(1)
                        }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Type of the RTDM's port.  The order is CLI compatible."
                ::= { rtdmPortEntry 3 }

        rtdmConnCardType OBJECT-TYPE
                SYNTAX  INTEGER (0..30)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Type of connection.  Valid values are ocmu(2),
                         ocmItu(3), mux(4), demux(5), mcm(8), w4cd(10), w2cmd(13), w4cm(21),
                         osam(20), fadm(6), oppm(7), fadmb(19), ocme(24), etc..."
                ::= { rtdmPortEntry 4}

        rtdmConnPort    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Conn port for RTDM's port.Possible values based on 
                         card types that can connect to RTDM are:
                         OFCM/OFCD: 1/2/3/4= port index, 5=EXP, 6=OUT/IN
                         W4CM/W4CD: 1=1510, 2=1530, 3=1550,
                                            4=1570, 5=EXP, 6=IN/OUT
                         W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT
                         OSAM: 1=IN, 2=OUT
                         FADM: 1=Conn A Tx, 2=Conn A Rx,  3=Local  Tx
                             4=Local  Rx, 5=Conn B Tx, 6=Conn B Rx
                         FADMB: 1=A/D, 2=EXP, 3=Local, 4=Rx
                         OCMU/OCMITU/MCM: 1=Link Tx, 2=Link Rx 
                         UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
                         4=Link B Rx, 5=Local Tx, 6=Local Rx "
                ::= { rtdmPortEntry 5 }

        rtdmConnShelf   OBJECT-TYPE
                SYNTAX  ShelfInput
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card conn to. Valid values are: 1 to 2."
                ::= { rtdmPortEntry 6 }

        rtdmConnSlot    OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card conn to.
                         A zero will be used for no connections."
                ::= { rtdmPortEntry 7 }

        -- The elements in the osam subgroup of the configuration group

        osamBootPromVer OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the osam boot prom code."
                ::= { osam 1 }

        osamROMSize     OBJECT-TYPE
                SYNTAX  INTEGER (0..1024)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total Size of the ROM in Kilobytes."
                ::= { osam 2 }

        osamNumSubDiv   OBJECT-TYPE
                SYNTAX  INTEGER (0..20)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Number of the ROM's subdivisions."
                ::= { osam 3 }

        osamSubDivTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF OsamSubDivEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the number of sub divisions
                         and the size of each subdivision in ROM memory"
                ::= { osam 4 }

        osamSubDivEntry OBJECT-TYPE
                SYNTAX  OsamSubDivEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { osamSubDivIndex }
                ::= { osamSubDivTable 1 }

        OsamSubDivEntry ::=
                SEQUENCE
                {
                        osamSubDivIndex         INTEGER,
                        osamSubDivDescr         DisplayString,
                        osamSubDivSize          INTEGER,
                        osamSubDivOffset        OCTET STRING
                }

        osamSubDivIndex OBJECT-TYPE
                SYNTAX  INTEGER (0..20)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Integer ID of each subdivision."
                ::= { osamSubDivEntry 1 }

        osamSubDivDescr OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..20))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Display name of each subdivision."
                ::= { osamSubDivEntry 2 }

        osamSubDivSize  OBJECT-TYPE
                SYNTAX  INTEGER (0..1024)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Size of each subdivision in Kbytes."
                ::= { osamSubDivEntry 3 }

        osamSubDivOffset    OBJECT-TYPE
                SYNTAX  OCTET STRING (SIZE (0..8))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Starting address of each sub division in HEX
                         format."
                ::= { osamSubDivEntry 4 }

        osamNumber      OBJECT-TYPE
                SYNTAX  INTEGER (0..32)
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of rows in the osam table."
                ::= { osam 5 }

        osamTable       OBJECT-TYPE
                SYNTAX  SEQUENCE OF OsamEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         osam card"
                ::= { osam 6 }

        osamEntry       OBJECT-TYPE
                SYNTAX  OsamEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { osamCardLocation, osamCardShelf, osamCardSlot }
                ::= { osamTable 1 }

        OsamEntry       ::=
                SEQUENCE
                {
                        osamCardLocation        CardLocation,
                        osamCardShelf           CardShelf,
                        osamCardSlot            INTEGER,
                        osamModelNum            ModelNum,
                        osamSerialNum           SerialString,
                        osamModelType           INTEGER,
                        osamHWName              CardName,
                        osamHWVersionID         VersionString,
                        osamHWDate              DateAndTime,
                        osamFWName              CardName,
                        osamFWVersionID         VersionString,
                        osamFWDate              DateAndTime,
                        osamCardName            CardName,
                        osamSetState            RebootType,
                        osamLaserState          FlagType,
                        osamOperationMode       INTEGER,
                        osamLaserBiasCurrent    INTEGER,
                        osamAmplifierGain       INTEGER,
                        osamConfigCommit        INTEGER,
                        osamNoiseFigure         INTEGER,
                        osamPathID              PathIdName,
                        osamAdminState          INTEGER,
                        osam2NoiseFigure        DisplayString,
                        osam2GainReq            DisplayString,
                        osam2OpPowerReq         DisplayString,
                        osamCleiNum             DisplayString,
                        osamNumPorts            INTEGER
                }

        osamCardLocation    OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Location of the module."
                ::= { osamEntry 1 }

        osamCardShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf number in which the module is plugged in."
                ::= { osamEntry 2 }

        osamCardSlot    OBJECT-TYPE
                SYNTAX  INTEGER (0..16)
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The slot number in which the module is plugged in.
                         If a 0 is written into this mib element, the module
                         will be deleted from the system."
                ::= { osamEntry 3 }

        osamModelNum    OBJECT-TYPE
                SYNTAX  ModelNum
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Manufacturing model number of the module."
                ::= { osamEntry 4 }

        osamSerialNum   OBJECT-TYPE
                SYNTAX  SerialString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Unique serial number of the module."
                ::= { osamEntry 5 }

        osamModelType   OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Model type of the module."
                ::= { osamEntry 6 }

        osamHWName      OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Manufacturing Hardware name of the module."
                ::= { osamEntry 7 }

        osamHWVersionID OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The current hardware version string of the module."
                ::= { osamEntry 8 }

        osamHWDate      OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Date of manufacturing of the electronics portion of 
                         the module."
                ::= { osamEntry 9 }

        osamFWName      OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Manufacturing Firmware name of the module."
                ::= { osamEntry 10 }

        osamFWVersionID OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The current firmware version string of the module."
                ::= { osamEntry 11 }

        osamFWDate      OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Release date for the firmware of the module."
                ::= { osamEntry 12 }

        osamCardName    OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "User configurable card name for the module." 
                ::= { osamEntry 13 }

        osamSetState    OBJECT-TYPE
                SYNTAX  RebootType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Instruct the osam module to do a reset.
                         A get on this will always return other."
                ::= { osamEntry 14 }

        osamLaserState  OBJECT-TYPE
                SYNTAX  FlagType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The operational state of the laser." 
                ::= { osamEntry 15 }

        osamOperationMode   OBJECT-TYPE
                SYNTAX  INTEGER { currentControlled(1), gainControlled(2), powerControlled(3) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Operation mode of the module. powerControlled(3) is not
                         supported by OSAM modules. currentControlled(1) is not 
                         supported OSAM-HP/LP modules." 
                ::= { osamEntry 16 }

        osamLaserBiasCurrent    OBJECT-TYPE
                SYNTAX  INTEGER (40..200)
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Constant current in mA to be used by the module when 
                         the operation mode is set to currentControlled. This 
                         value can't be set if operation mode is set to 
                         gainControlled.
                         Applicable only to OSAM module"
                ::= { osamEntry 17 }

        osamAmplifierGain   OBJECT-TYPE
                SYNTAX  INTEGER (0..30)
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Constant gain in dB to be used by the module when the 
                         operation mode is set to gainControlled. This value
                         can't be set if operation mode is set to 
                         currentControlled.
                         Not applicable to OSAM-HP/LP module"
                ::= { osamEntry 18 }

        osamConfigCommit    OBJECT-TYPE
                SYNTAX  INTEGER { other(1), save(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "This allows the current module configuration to be
                         stored in permanent storage."
                ::= { osamEntry 19 }

        osamNoiseFigure OBJECT-TYPE
                SYNTAX  INTEGER (0..10)
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The calibrated noise figure of the gain block in dB.
                         Applicable only to OSAM module"
                ::= { osamEntry 20 }

        osamPathID      OBJECT-TYPE
                SYNTAX  PathIdName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Upsr Path ID name that this card is associated with.  
                         Set input equal NULL will remove the card off the path 
                         and also remove the path if there is no card left 
                         associate with that path." 
                ::= { osamEntry 21 }

        osamAdminState  OBJECT-TYPE
                SYNTAX  INTEGER { disable(1), enable(2), na(3) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Administrative control over that osam card. Default value is enable.
                         When disabled, no alarms/events gets
                         generated."
                ::= { osamEntry 22 }

        osam2NoiseFigure    OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The calibrated noise figure of the gain block in dBm.
                         Applicable only to OSAM-HP/LP module"
                ::= { osamEntry 23 }

        osam2GainReq    OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Constant gain in dB to be used by the module when the 
                         operation mode is set to gainControlled. This value
                         can't be set if operation mode is set to 
                         powerControlled. Range is 0-16.5db(LP) and 0-23.3db(HP)
                         Applicable only to OSAM-HP/LP module"
                ::= { osamEntry 24 }

        osam2OpPowerReq OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Constant output power in dBm to be used by the module when the 
                         operation mode is set to powerControlled. This value
                         can't be set if operation mode is set to 
                         gainControlled. Range is 0-9dbm (LP) and 0-18dbm(HP) 
                         Applicable only to OSAM-HP/LP module"
                ::= { osamEntry 25 }

        osamCleiNum     OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CLEI number of the osam Card."
                ::= { osamEntry 26 }

        osamNumPorts    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total port numbers on each OSAM card."
                ::= { osamEntry 27 }

        osamPortTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF OsamPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the physical connection for each
                         OSAM card's port."
                ::= { osam 7 }

        osamPortEntry   OBJECT-TYPE
                SYNTAX  OsamPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { osamPortCardShelf, osamPortCardSlot, osamPortType }
                ::= { osamPortTable 1 }

        OsamPortEntry   ::=
                SEQUENCE
                {
                        osamPortCardShelf       CardShelf,
                        osamPortCardSlot        INTEGER,
                        osamPortType            INTEGER,
                        osamConnCardType        CardType,
                        osamConnPort            INTEGER,
                        osamConnShelf           INTEGER,
                        osamConnSlot            INTEGER,
                        osamPortCardType        CardType,
                        osamConnLocation        CardLocation,
                        osamConnChassisID       DisplayString,
                        osamConnSystemName      DisplayString,
                        osamConnIpAddress       IpAddress 
                }


        osamPortCardShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2."
                ::= { osamPortEntry 1 }

        osamPortCardSlot    OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { osamPortEntry 2 }

        osamPortType    OBJECT-TYPE 
                SYNTAX  INTEGER { in(1), out(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Type of the OSAM's port."
                ::= { osamPortEntry 3 }

        osamConnCardType    OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Module type connectioned to osam port."
                ::= { osamPortEntry 4}

        osamConnPort    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Conn port for OSAM's port. Possible values based on 
                         card types that can be connected to OSAM are:
                         FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local  Tx
                               4=Local  Rx, 5=Conn B Tx, 6=Conn B Rx
                         OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1: 1=Link Tx, 2=Link Rx 
                         OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN
                         OSAM: 1=IN, 2=OUT
                         W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT
                         W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT
                         UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
                                    4=Link B Rx, 5=Local Tx, 6=Local Rx."
                ::= { osamPortEntry 5 }

        osamConnShelf   OBJECT-TYPE
                SYNTAX  ShelfInput
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card conn to. Valid values are: 1 to 2." 
                ::= { osamPortEntry 6 }

        osamConnSlot    OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card conn to. To delete a 
                         connection associated with a specified port, set this 
                         variable to 0."
                ::= { osamPortEntry 7 }

        osamPortCardType    OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Type of OSAM module."
                ::= { osamPortEntry 8}

        osamConnLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The chassis's location of the card connected to."
                ::= { osamPortEntry 9}

        osamConnChassisID OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Chassis ID of the connected node.  User config. If local connection,
                         a set on it would return an error; would be automatically be set to
                         the chassis Id of the local node."
                ::= { osamPortEntry 10}

        osamConnSystemName OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "System Name of the connected node.  User config. If local connection,
                         a set on it would return an error; would be automatically be set to
                         the sysetem name of the local node."
                ::= { osamPortEntry 11}

        osamConnIpAddress OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "IpAddress of the connected node.  User config. If local
                         connection, a set on it would return an error; would be automatically
                         be set to the IP address of the node."
                ::= { osamPortEntry 12}

        -- The elements in the rsm subgroup of the configuration group

        rsmBootPromVer  OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the rsm
             Boot PROM code"
                ::= { rsm 1 }

        rsmROMSize      OBJECT-TYPE
                SYNTAX  INTEGER (0..1024)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total Size of the ROM in Kilobyes"
                ::= { rsm 2 }

        rsmNumSubDiv    OBJECT-TYPE
                SYNTAX  INTEGER (0..20)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Number of the subdivisions of the ROM."
                ::= { rsm 3 }

        rsmSubDivTable  OBJECT-TYPE
                SYNTAX  SEQUENCE OF RsmSubDivEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the number of sub divisions
                         and the size of each subdivision in ROM memory"
                ::= { rsm 4 }

        rsmSubDivEntry  OBJECT-TYPE
                SYNTAX  RsmSubDivEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { rsmSubDivIndex }
                ::= { rsmSubDivTable 1 }

        RsmSubDivEntry  ::=
                SEQUENCE
                {
                        rsmSubDivIndex          INTEGER,
                        rsmSubDivDescr          DisplayString,
                        rsmSubDivSize           INTEGER,
                        rsmSubDivOffset         OCTET STRING
                }

        rsmSubDivIndex  OBJECT-TYPE
                SYNTAX  INTEGER (0..20)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Integer ID of each sub division in the ROM.  The order
                         of numbering is from the top of the ROM to the bottom
                         of the ROM."
                ::= { rsmSubDivEntry 1 }

        rsmSubDivDescr  OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..20))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Display Name of each Sub Division in ROM"
                ::= { rsmSubDivEntry 2 }

        rsmSubDivSize   OBJECT-TYPE
                SYNTAX  INTEGER (0..1024)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Size of each sub division in ROM in kilobytes"
                ::= { rsmSubDivEntry 3 }

        rsmSubDivOffset OBJECT-TYPE
                SYNTAX  OCTET STRING (SIZE (0..8))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Starting address of each sub division in the ROM
                         in HEX notation."
                ::= { rsmSubDivEntry 4 }

        rsmNumber       OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of RSM rows in the following table.  This 
                         number is automatically updated whenever a new row is 
                         added to the table below."
                ::= { rsm 5 }

        rsmTable        OBJECT-TYPE
                SYNTAX  SEQUENCE OF RsmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         RSM card"
                ::= { rsm 6 }

        rsmEntry        OBJECT-TYPE
                SYNTAX  RsmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { rsmCardLocation, rsmCardShelf, rsmCardSlot }
                ::= { rsmTable 1 }

        RsmEntry        ::=
                SEQUENCE
                {
                        rsmCardLocation         CardLocation,
                        rsmCardShelf            CardShelf,
                        rsmCardSlot             SlotInput,
                        rsmModelNum             DisplayString,
                        rsmOpticsMfgDate        DateAndTime,
                        rsmSerialNum            SerialString,
                        rsmModelType            INTEGER,
                        rsmHWName               CardName,
                        rsmCardName             CardName,
                        rsmFWName               DisplayString,          
                        rsmFWVersionID          VersionString,
                        rsmFWDate               DateAndTime,
                        rsmSetState             RebootType,
                        rsmRxInsertionLoss      DisplayString,
                        rsmRxComInsertionLoss   DisplayString,
                        rsmWorkingWavelength    INTEGER,
                        rsmLinkAPathID          PathIdName,
                        rsmLinkBPathID          PathIdName,
                        rsmAdminState           INTEGER,
                        rsmCleiNum              DisplayString,
                        rsmNumPorts             INTEGER
                }

        rsmCardLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Location of the RSM card.  Valid values are: Local in
                         the same chassis."
                ::= { rsmEntry 1 }

        rsmCardShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2."
                ::= { rsmEntry 2 }

        rsmCardSlot     OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the module is in.  The range
                         of valid values range from 1 through 17 depending on
                         the chassis type and the shelf the module is in.
                         To delete this card, set this variable to 0."
                ::= { rsmEntry 3 }

        rsmModelNum     OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "RSM's model number."
                ::= { rsmEntry 4 }

        rsmOpticsMfgDate    OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of manufacturing of the optics
                         on the RSM card."
                ::= { rsmEntry 5 }

        rsmSerialNum    OBJECT-TYPE
                SYNTAX  SerialString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Serial # of the RSM card."
                ::= { rsmEntry 6 }

        rsmModelType    OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Model type of the RSM."
                ::= { rsmEntry 7 }

        rsmHWName       OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Manufacturing Hardware name of the RSM Card."
                ::= { rsmEntry 8 }

        rsmCardName     OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "User configurable card name." 
                ::= { rsmEntry 9 }

        rsmFWName       OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "RSM's Firmware Name."
                ::= { rsmEntry 10 }

        rsmFWVersionID  OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the RSM FW code."
                ::= { rsmEntry 11 }

        rsmFWDate       OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of latest Firmware of the RSM card."
                ::= { rsmEntry 12 }      

        rsmSetState     OBJECT-TYPE
                SYNTAX  RebootType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Instruct the rsm to do a warmboot. A get on this will
                         always return an other." 
                ::= { rsmEntry 13 }

        rsmRxInsertionLoss   OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Insertion loss for Rx Path." 
                ::= { rsmEntry 14 }

        rsmRxComInsertionLoss   OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Insertion loss for Rx Com Path." 
                ::= { rsmEntry 15 }

        rsmWorkingWavelength    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The RSM ITU number." 
                ::= { rsmEntry 16 }

        rsmLinkAPathID  OBJECT-TYPE
                SYNTAX  PathIdName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Rsm LinkA Path ID name that this card is associated with.  
                         Set input equal NULL will remove the card off the path 
                         and also remove the path if there is no card left 
                         associate with that path."
                ::= { rsmEntry 17 }

        rsmLinkBPathID  OBJECT-TYPE
                SYNTAX  PathIdName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Rsm LinkB Path ID name that this card is associated with.  
                         Set input equal NULL will remove the card off the path 
                         and also remove the path if there is no card left 
                         associate with that path."
                ::= { rsmEntry 18 }
                

        rsmAdminState   OBJECT-TYPE
                SYNTAX  INTEGER { disable(1), enable(2), na(3) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Administrative control over that rsm card. Default value is enable.
                         When disabled, no alarms/events gets
                         generated."
                ::= { rsmEntry 19 }

        rsmCleiNum      OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CLEI number of the rsm Card."
                ::= { rsmEntry 20 }

        rsmNumPorts    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total port numbers on each RSM card."
                ::= { rsmEntry 21 }

        rsmPortTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF RsmPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         RSM card's port."
                ::= { rsm 7 }

        rsmPortEntry    OBJECT-TYPE
                SYNTAX  RsmPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { rsmPortCardShelf, rsmPortCardSlot, rsmPortType }
                ::= { rsmPortTable 1 }

        RsmPortEntry    ::=
                SEQUENCE 
                {
                        rsmPortCardShelf        CardShelf,
                        rsmPortCardSlot         SlotInput,
                        rsmPortType             INTEGER,
                        rsmConnCardType         CardType,                       
                        rsmConnShelf            ShelfInput,
                        rsmConnSlot             SlotInput,
                        rsmConnPort             INTEGER                     
                }

        rsmPortCardShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2."
                ::= { rsmPortEntry 1 }

        rsmPortCardSlot OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { rsmPortEntry 2 }

        rsmPortType     OBJECT-TYPE 
                SYNTAX  INTEGER { localARx(1), localATx(2), localBRx(3), localBTx(4) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Type of the RSM's port.  The order is CLI compatible."
                ::= { rsmPortEntry 3 }

        rsmConnCardType OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Module type connected to rsm port. The valid module types
                         are OCM10G/OCME/OCMITU/OCMU."
                ::= { rsmPortEntry 4}

        rsmConnShelf   OBJECT-TYPE
                SYNTAX  ShelfInput
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card conn to. Valid values are: 1 to 2." 
                ::= { rsmPortEntry 5 }

        rsmConnSlot     OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card conn to. To delete a 
                         connection associated with a specified port, set this 
                         variable to 0."
                ::= { rsmPortEntry 6 }

        rsmConnPort     OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Conn port for RSM's port. Only OCM10G/OCME/OCMITU/OCMU 
                         can be connected to RSM. The possible values are:
                         OCM10G/OCME/OCMITU/OCMU: 3=CPE Tx, 4=CPE Rx"
                ::= { rsmPortEntry 7 }
                
        -- The elements in the upsm subgroup of the configuration group

        upsmBootPromVer OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the rsm
                         Boot PROM code"
                ::= { upsm 1 }

        upsmROMSize     OBJECT-TYPE
                SYNTAX  INTEGER (0..1024)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total Size of the ROM in Kilobyes"
                ::= { upsm 2 }

        upsmNumSubDiv   OBJECT-TYPE
                SYNTAX  INTEGER (0..20)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Number of the subdivisions of the ROM."
                ::= { upsm 3 }

        upsmSubDivTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF UpsmSubDivEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the number of sub divisions
                         and the size of each subdivision in ROM memory"
                ::= { upsm 4 }

        upsmSubDivEntry OBJECT-TYPE
                SYNTAX  UpsmSubDivEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { upsmSubDivIndex }
                ::= { upsmSubDivTable 1 }

        UpsmSubDivEntry ::=
                SEQUENCE
                {
                        upsmSubDivIndex         INTEGER,
                        upsmSubDivDescr         DisplayString,
                        upsmSubDivSize          INTEGER,
                        upsmSubDivOffset        OCTET STRING
                }

        upsmSubDivIndex OBJECT-TYPE
                SYNTAX  INTEGER (0..20)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Integer ID of each sub division in the ROM.  The order
                         of numbering is from the top of the ROM to the bottom
                         of the ROM."
                ::= { upsmSubDivEntry 1 }

        upsmSubDivDescr OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..20))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Display Name of each Sub Division in ROM"
                ::= { upsmSubDivEntry 2 }

        upsmSubDivSize  OBJECT-TYPE
                SYNTAX  INTEGER (0..1024)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Size of each sub division in ROM in kilobytes"
                ::= { upsmSubDivEntry 3 }

        upsmSubDivOffset    OBJECT-TYPE
                SYNTAX  OCTET STRING (SIZE (0..8))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Starting address of each sub division in the ROM
                         in HEX notation."
                ::= { upsmSubDivEntry 4 }

        upsmNumber      OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of UPSM rows in the following table.  This 
                         number is automatically updated whenever a new row is 
                         added to the table below."
                ::= { upsm 5 }

        upsmTable       OBJECT-TYPE
                SYNTAX  SEQUENCE OF UpsmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         UPSM card"
                ::= { upsm 6 }

        upsmEntry       OBJECT-TYPE
                SYNTAX  UpsmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { upsmCardLocation, upsmCardShelf, upsmCardSlot }
                ::= { upsmTable 1 }

        UpsmEntry       ::=
                SEQUENCE
                {
                        upsmCardLocation            CardLocation,
                        upsmCardShelf               CardShelf,
                        upsmCardSlot                SlotInput,
                        upsmModelNum                DisplayString,
                        upsmOpticsMfgDate           DateAndTime,
                        upsmSerialNum               SerialString,
                        upsmModelType               INTEGER,
                        upsmHWName                  CardName,
                        upsmCardName                CardName,
                        upsmFWName                  DisplayString,          
                        upsmFWVersionID             VersionString,
                        upsmFWDate                  DateAndTime,
                        upsmSetState                RebootType,
                        upsmRxInsertionLoss         DisplayString,
                        upsmTxInsertionLoss         DisplayString,
                        upsmMarginForSwitch         INTEGER,
                        upsmMinProtPowerForSwitch   INTEGER,
                        upsmDebounce                INTEGER,
                        upsmBlackOutTime            INTEGER,
                        upsmSwitch                  INTEGER,
                        upsmLinkAPathID             PathIdName,
                        upsmLinkBPathID             PathIdName,
                        upsmAdminState              INTEGER,
                        upsmCleiNum                 DisplayString,
                        upsmSwitchState             INTEGER,
                        upsmNumPorts                INTEGER
                }

        upsmCardLocation    OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Location of the UPSM card.  Valid values are: Local in
                         the same chassis."
                ::= { upsmEntry 1 }

        upsmCardShelf   OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2."
                ::= { upsmEntry 2 }

        upsmCardSlot    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the module is in.  The range
                         of valid values range from 1 through 17 depending on
                         the chassis type and the shelf the module is in.
                         To delete this card, set this variable to 0."
                ::= { upsmEntry 3 }

        upsmModelNum    OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "UPSM's model number."
                ::= { upsmEntry 4 }

        upsmOpticsMfgDate OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of manufacturing of the optics
                         on the UPSM card."
                ::= { upsmEntry 5 }

        upsmSerialNum   OBJECT-TYPE
                SYNTAX  SerialString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Serial # of the UPSM card."
                ::= { upsmEntry 6 }

        upsmModelType   OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Model type of the UPSM."
                ::= { upsmEntry 7 }

        upsmHWName      OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Manufacturing Hardware name of the UPSM Card."
                ::= { upsmEntry 8 }

        upsmCardName    OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "User configurable card name." 
                ::= { upsmEntry 9 }

        upsmFWName      OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "UPSM's Firmware Name."
                ::= { upsmEntry 10 }

        upsmFWVersionID OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the UPSM FW code."
                ::= { upsmEntry 11 }

        upsmFWDate      OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of latest Firmware of the UPSM card."
                ::= { upsmEntry 12 }      

        upsmSetState    OBJECT-TYPE
                SYNTAX  RebootType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Instruct the upsm to do a warmboot. A get on this will
             always return an other." 
                ::= { upsmEntry 13 }

        upsmRxInsertionLoss   OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Insertion loss for Rx Path." 
                ::= { upsmEntry 14 }

        upsmTxInsertionLoss   OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Insertion loss for Tx Path." 
                ::= { upsmEntry 15 }

        upsmMarginForSwitch OBJECT-TYPE
                SYNTAX  INTEGER (-32..-6)
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The UPSM switching threshold for protection switch to occur.  
                         The limit is from -32 to -6. Switching threshold must be 1 dBm
                         or more less than the minimum switch power." 
                ::= { upsmEntry 16 }

        upsmMinProtPowerForSwitch   OBJECT-TYPE
                SYNTAX  INTEGER (-30..-5)
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The minimum protection link power to allow protection switch 
                         to function.  The limit is from -30 to -5.  This value should 
                         be 1 dBm or more greater than the switch margin." 
                ::= { upsmEntry 17 }

        upsmDebounce    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of times to measure low power condition 
                         before performing protection switch." 
                ::= { upsmEntry 18 }

        upsmBlackOutTime OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The time after protection switch before allowing 
                         another protection switch." 
                ::= { upsmEntry 19 }

        upsmSwitch      OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            other(1),
                            switchToLinkA(2),
                            switchToLinkB(3), 
                            toggle(4),
                            enableAutoSwitch(6),
                            enableSwitchtoLinkA(7),
                            enableSwitchtoLinkB(8)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The Link switch control. switchToLinkA or
                         switchToLinkB option would disable auto switch
                         functionality. Auto switch functionality can
                         be turned on by setting to enableAutoSwitch
                         option " 
                ::= { upsmEntry 20 }

        upsmLinkAPathID OBJECT-TYPE
                SYNTAX  PathIdName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Upsm LinkA Path ID name that this card is associated with.  
                         Set input equal NULL will remove the card off the path 
                         and also remove the path if there is no card left 
                         associate with that path."
                ::= { upsmEntry 21 }

        upsmLinkBPathID OBJECT-TYPE
                SYNTAX  PathIdName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Upsm LinkB Path ID name that this card is associated with.  
                         Set input equal NULL will remove the card off the path 
                         and also remove the path if there is no card left 
                         associate with that path."
                ::= { upsmEntry 22 }

        upsmAdminState  OBJECT-TYPE
                SYNTAX  INTEGER { disable(1), enable(2), na(3) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Administrative control over that upsm card. Default value is enable.
                         When disabled, no alarms/events gets
                         generated."
                ::= { upsmEntry 23}

        upsmCleiNum     OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CLEI number of the upsm Card."
                ::= { upsmEntry 24 }

        upsmSwitchState OBJECT-TYPE
                SYNTAX  INTEGER { auto(1), forced(2) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The switching state. Switching state may be 
                         either auto or forced.  The auto state means
                         automatic switching is enabled.  Forced state 
                         means swithcing is disabled and has been forced
                         to the current active link." 
                ::= { upsmEntry 25 }

        upsmNumPorts    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total port numbers on each UPSM card."
                ::= { upsmEntry 26 }

        upsmPortTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF UpsmPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         UPSM card's port."
                ::= { upsm 7 }

        upsmPortEntry   OBJECT-TYPE
                SYNTAX  UpsmPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { upsmPortCardShelf, upsmPortCardSlot, upsmPortType }
                ::= { upsmPortTable 1 }

        UpsmPortEntry   ::=
                SEQUENCE 
                {
                        upsmPortCardShelf       CardShelf,
                        upsmPortCardSlot        SlotInput,
                        upsmPortType            INTEGER,
                        upsmConnLocation        CardLocation,
                        upsmConnIpAddress       IpAddress,
                        upsmConnChassisID       NodeName,
                        upsmConnSystemName      NodeName,
                        upsmConnCardType        INTEGER,
                        upsmConnPort            INTEGER,
                        upsmConnShelf           ShelfInput,
                        upsmConnSlot            SlotInput                           
                }

        upsmPortCardShelf OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2."
                ::= { upsmPortEntry 1 }

        upsmPortCardSlot OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { upsmPortEntry 2 }

        upsmPortType    OBJECT-TYPE 
                SYNTAX  INTEGER
                        {
                            linkATx(1),
                            linkARx(2),
                            linkBTx(3),
                            linkBRx(4),
                            localTx(5),
                            localRx(6)
                        }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Type of the UPSM's port.  The order is CLI compatible."
                ::= { upsmPortEntry 3 }

        upsmConnLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The chassis's location of the card conn to."
                ::= { upsmPortEntry 4 }

        upsmConnIpAddress OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "IpAddress of the connected node.  User config. If local
                         connection, a set on it would return an error; would be automatically
                         be set to the IP address of the node "
                ::= { upsmPortEntry 5}

        upsmConnChassisID OBJECT-TYPE
                SYNTAX  DisplayString(SIZE(0..16))
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Chassis ID of the connected node.  User config. If local connection,
                         a set on it would return an error; would be automatically be set to
                         the chassis Id of the local node"
                ::= { upsmPortEntry 6}

        upsmConnSystemName OBJECT-TYPE
                SYNTAX  DisplayString(SIZE(0..32))
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "System Name of the connected node.  User config. If local connection,
                         a set on it would return an error; would be automatically be set to
                         the sysetem name of the local node."
                ::= { upsmPortEntry 7}

        upsmConnCardType OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Module type connected to upsm port."
                ::= { upsmPortEntry 8}

        upsmConnPort    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Conn port for UPSM's port. Possible values based on 
                         card types that can connect to UPSM are:
                         FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local  Tx
                               4=Local  Rx, 5=Conn B Tx, 6=Conn B Rx
                         OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1/MCMESC: 1=Link Tx, 2=Link Rx 
                         OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN
                         OSAM: 1=IN, 2=OUT
                         W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT
                         W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT
                         UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
                                    4=Link B Rx, 5=Local Tx, 6=Local Rx."
                ::= { upsmPortEntry 9 }

        upsmConnShelf   OBJECT-TYPE
                SYNTAX  ShelfInput
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card conn to. Valid values are: 1 to 2." 
                ::= { upsmPortEntry 10 }

        upsmConnSlot    OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card conn to. To delete a 
                         connection associated with a specified port, set this 
                         variable to 0."
                ::= { upsmPortEntry 11 }

        -- The table of mcmesc

        mcmescBootPromVer OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the mcmesc Boot PROM code"
                ::= { mcmesc 1 }

        mcmescROMSize   OBJECT-TYPE
                SYNTAX  INTEGER (0..1024)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total Size of the ROM in Kilobyes"
                ::= { mcmesc 2 }

        mcmescNumSubDiv OBJECT-TYPE
                SYNTAX  INTEGER (0..20)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Number of the subdivisions of the ROM."
                ::= { mcmesc 3 }

        mcmescSubDivTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF McmescSubDivEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the number of sub divisions
                         and the size of each subdivision in ROM memory"
                ::= { mcmesc 4 }

        mcmescSubDivEntry OBJECT-TYPE
                SYNTAX  McmescSubDivEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { mcmescSubDivIndex }
                ::= { mcmescSubDivTable 1 }

        McmescSubDivEntry  ::=
                SEQUENCE
                {
                        mcmescSubDivIndex       INTEGER,
                        mcmescSubDivDescr       DisplayString,
                        mcmescSubDivSize        INTEGER,
                        mcmescSubDivOffset      OCTET STRING
                }

        mcmescSubDivIndex OBJECT-TYPE
                SYNTAX  INTEGER (0..20)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Integer ID of each sub division in the ROM.  The order
                         of numbering is from the top of the ROM to the bottom
                         of the ROM."
                ::= { mcmescSubDivEntry 1 }

        mcmescSubDivDescr OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..20))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Display Name of each Sub Division in ROM"
                ::= { mcmescSubDivEntry 2 }

        mcmescSubDivSize OBJECT-TYPE
                SYNTAX  INTEGER (0..1024)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Size of each sub division in ROM in kilobytes"
                ::= { mcmescSubDivEntry 3 }

        mcmescSubDivOffset OBJECT-TYPE
                SYNTAX  OCTET STRING (SIZE (0..8))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Starting address of each sub division in the ROM
                         in HEX notation."
                ::= { mcmescSubDivEntry 4 }

        mcmescNumber    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of rows in the following table.  This number
                         is automatically updated whenever a new row is added
                         to the table below."
                ::= { mcmesc 5 }

        mcmescTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF McmescEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         mcmesc module"
                ::= { mcmesc 6 }

        mcmescEntry     OBJECT-TYPE
                SYNTAX  McmescEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { mcmescCardLocation, mcmescCardShelf, mcmescCardSlot }
                ::= { mcmescTable 1 }

        McmescEntry     ::=
                SEQUENCE
                {
                        mcmescCardLocation              CardLocation,
                        mcmescCardShelf                 CardShelf,
                        mcmescCardSlot                  INTEGER,
                        mcmescMfgDate                   DateAndTime,
                        mcmescSerialNum                 SerialString,
                        mcmescModelType                 INTEGER,
                        mcmescModelNum                  DisplayString,
                        mcmescName                      CardName,
                        mcmescHWName                    CardName,
                        mcmescNumPorts                  INTEGER,
                        mcmescFWVersionID               VersionString,
                        mcmesc2ndFWVersionID            VersionString,
                        mcmescFPGAVersionID             VersionString,
                        mcmesc2ndFPGAVersionID          VersionString,
                        mcmescBoardSerialNum            SerialString,
                        mcmescBoardVersionID            VersionString,
                        mcmescDaughterBoard1SerialNum   SerialString,
                        mcmescDaughterBoard1VersionID   VersionString,
                        mcmescDaughterBoard2SerialNum   SerialString,
                        mcmescDaughterBoard2VersionID   VersionString,
                        mcmescCleiNum                   DisplayString,
                        mcmescLinkWavelength            DisplayString,
                        mcmescLinkSfpSerialNum          SfpSerialString,
                        mcmescAdminState                INTEGER,
                        mcmescLinkName                  LinkName,
                        mcmescPathID                    PathIdName,
                        mcmescOverride                  Boolean,
                        mcmescPerfInterval              INTEGER,
                        mcmescCpeRxSigLowThreshold      INTEGER,
                        mcmescLinkRxSigLowThreshold     INTEGER,
                        mcmescCpeErrEventThreshold      INTEGER,
                        mcmescCpeErrAlarmThreshold      INTEGER,
                        mcmescLinkErrEventThreshold     INTEGER,
                        mcmescLinkErrAlarmThreshold     INTEGER,
                        mcmescTestSequence              FlagType,
                        mcmescConnMuxShelf              ShelfInput,
                        mcmescConnMuxSlot               SlotInput,
                        mcmescConnMuxPort               INTEGER,
                        mcmescConnDemuxShelf            ShelfInput,
                        mcmescConnDemuxSlot             SlotInput,
                        mcmescConnDemuxPort             INTEGER,
                        mcmescConnTxOcmShelf            ShelfInput,
                        mcmescConnTxOcmSlot             SlotInput,
                        mcmescConnTxOcmPort             INTEGER,
                        mcmescConnTxOcmShelfSlot        DisplayString,
                        mcmescConnTxOcmDelete           Boolean,
                        mcmescConnRxOcmShelf            ShelfInput,
                        mcmescConnRxOcmSlot             SlotInput,
                        mcmescConnRxOcmPort             INTEGER,
                        mcmescConnRxOcmShelfSlot        DisplayString,                        
                        mcmescConnRxOcmDelete           Boolean,                        
                        mcmescSetState                  INTEGER,
                        mcmescLinkClrErrCount           INTEGER
                }

        mcmescCardLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Location of the mcmesc Module."
                ::= { mcmescEntry 1 }

        mcmescCardShelf OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf of the mcmesc is in.  Valid values are: 1..2"
                ::= { mcmescEntry 2 }

        mcmescCardSlot  OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the module is in.  The range
                         of valid values range from 1 through 17 depending on
                         the chassis type and the shelf the module is in.
                         To delete this card, set this variable to 0."
                ::= { mcmescEntry 3 }

        mcmescMfgDate   OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of calibration of the mcmesc card"
                ::= { mcmescEntry 4 }

        mcmescSerialNum OBJECT-TYPE
                SYNTAX  SerialString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Serial # of the mcmesc card."
                ::= { mcmescEntry 5 }

        mcmescModelType OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Model type of the mcmesc"
                ::= { mcmescEntry 6 }

        mcmescModelNum  OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Model number of the MCMESC card. Up to 15 characters"
                ::= { mcmescEntry 7 }

        mcmescName      OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Display (Network) name of the MCMESC Module"
                ::= { mcmescEntry 8 }

        mcmescHWName    OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Display Hardware name of the MCMESC Card."
                ::= { mcmescEntry 9 }

        mcmescNumPorts  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total port numbers of MCM module."
                ::= { mcmescEntry 10 }

        mcmescFWVersionID OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the MCMESC FW code"
                ::= { mcmescEntry 11 }

        mcmesc2ndFWVersionID OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The version string of the MCMESC second FW code"
                ::= { mcmescEntry 12 }

        mcmescFPGAVersionID OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the MCMESC FPGA code"
                ::= { mcmescEntry 13 }

        mcmesc2ndFPGAVersionID OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The version string of the MCMESC second FPGA code"
                ::= { mcmescEntry 14 }

        mcmescBoardSerialNum OBJECT-TYPE
                SYNTAX  SerialString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Serial # of the MCMESC board."
                ::= { mcmescEntry 15 }

        mcmescBoardVersionID OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The version string of the MCMESC board"
                ::= { mcmescEntry 16 }

        mcmescDaughterBoard1SerialNum OBJECT-TYPE
                SYNTAX  SerialString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Serial # of the MCMESC daughter board 1."
                ::= { mcmescEntry 17 }

        mcmescDaughterBoard1VersionID OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The version string of the MCMESC daughter board 1"
                ::= { mcmescEntry 18 }

        mcmescDaughterBoard2SerialNum OBJECT-TYPE
                SYNTAX  SerialString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Serial # of the MCMESC daughter board 2."
                ::= { mcmescEntry 19 }

        mcmescDaughterBoard2VersionID OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The version string of the MCMESC daughter board 2"
                ::= { mcmescEntry 20 }

        mcmescCleiNum   OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CLEI number of the MCMESC Card."
                ::= { mcmescEntry 21 }

        mcmescLinkWavelength OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Link Wavelength of the MCMESC card"
                ::= { mcmescEntry 22 }

        mcmescLinkSfpSerialNum OBJECT-TYPE
                SYNTAX  SfpSerialString 
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Link port's SFP serial number."
                ::= { mcmescEntry 23 }

        mcmescAdminState OBJECT-TYPE
                SYNTAX  INTEGER { disable(1), enable(2), na(3) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Administrative control over that MCMESC card. Default value is enable.
                         When disabled, no alarms/events gets generated."
                ::= {  mcmescEntry 24 }

        mcmescLinkName  OBJECT-TYPE
                SYNTAX  LinkName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Link name for fiber between the local and the
                         remote MCMESC card."
                ::= { mcmescEntry 25 }

        mcmescPathID    OBJECT-TYPE
                SYNTAX  PathIdName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Upsr Path ID name that this card is associated with.  
                         Set input equal NULL will remove the card off the path 
                         and also remove the path if there is no card left 
                         associate with that path."
                ::= { mcmescEntry 26 }

        mcmescOverride  OBJECT-TYPE
                SYNTAX  INTEGER { yes(1), no(2), na(3) }      
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "MPM overrides the settings stored on MCMESC card upon 
                         detecting it. Default value is no. Not applicable to 
                         remote MCMESC."
                ::= {  mcmescEntry 27 }

        mcmescPerfInterval  OBJECT-TYPE
                SYNTAX  INTEGER (60..3600)
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The interval, in seconds, in which MCMESC collects the 
                         performance data, ranging 60 to 3600."
                ::= {  mcmescEntry 28 }

        mcmescCpeRxSigLowThreshold OBJECT-TYPE
                SYNTAX  INTEGER (-29..-7)
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The threshold of reporting CPE port Rx signal low alarm, 
                         in dBm, ranging from -29 to -7."
                ::= {  mcmescEntry 29 }

        mcmescLinkRxSigLowThreshold     OBJECT-TYPE
                SYNTAX  INTEGER (-29..-7)
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The threshold of reporting Link Rx signal low alarm,
                         in dBm, ranging from -29 to -7."
                ::= {  mcmescEntry 30 }

        mcmescCpeErrEventThreshold OBJECT-TYPE
                SYNTAX  INTEGER (5..15)
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The threshold of reporting CPE error event, in the form of
                         1.0E-x. Only x needs to be set and will be read. The range 
                         of x is from 5 to 15, however, input should be an 
                         absolute value if using mib browser. This threshold should 
                         be lower than the value of 
                         mcmescCpeErrAlarmThreshold, i.e., the absolute value 
                         should be higher than of mcmescCpeErrAlarmThreshold."
                ::= {  mcmescEntry 31 }

        mcmescCpeErrAlarmThreshold OBJECT-TYPE
                SYNTAX  INTEGER (4..14)
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The threshold of reporting CPE error alarm, in the form of
                         1.0E-x. The range of x is from 4 to 14, however, input 
                         should be an absolute value if using mib browser. This 
                         threshold should be higher than the value of 
                         mcmescCpeErrEventThreshold, i.e., the absolute value 
                         should be lower than of mcmescCpeErrEventThreshold."
                ::= {  mcmescEntry 32 }

        mcmescLinkErrEventThreshold OBJECT-TYPE
                SYNTAX  INTEGER (5..15)
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The threshold of reporting LINK error event, in the form of
                         1.0E-x. The range of x is from 5 to 15, however, input 
                         should be an absolute value if using mib browser. This 
                         threshold should be lower than the value of 
                         mcmescLinkErrAlarmThreshold, i.e., the absolute value 
                         should be higher than of mcmescLinkErrAlarmThreshold."
                ::= {  mcmescEntry 33 }

        mcmescLinkErrAlarmThreshold OBJECT-TYPE
                SYNTAX  INTEGER (4..14)
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The threshold of reporting LINK error alarm, in the form of
                         1.0E-x. The range of x is from 4 to 14, however, input
                         should be an absolute value if using mib browser. This 
                         threshold should be higher than the value of 
                         mcmescLinkErrEventThreshold, i.e., the absolute value 
                         should be lower than of mcmescLinkErrEventThreshold."
                ::= {  mcmescEntry 34 }


        mcmescTestSequence OBJECT-TYPE
                SYNTAX  FlagType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Turn on or off the test-sequence on link. The operation 
                         will take place on the remote MCMESC if it's connected."
                ::= {  mcmescEntry 35 }

       mcmescConnMuxShelf OBJECT-TYPE
                SYNTAX  ShelfInput
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The connected W4CM/UPSM shelf."
                ::= { mcmescEntry 36 }

       mcmescConnMuxSlot OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The connected W4CM/UPSM slot."
                ::= { mcmescEntry 37 }

        mcmescConnMuxPort OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The connected W4CM/UPSM port.
                         W4CM: 1=1470/1510, 2=1490/1530, 3=15501590/,
                               4=1570/1610, 5=EXP, 6=IN/OUT;
                         UPSM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
                               4=Link B Rx, 5=Local Tx, 6=Local Rx."
                 ::= { mcmescEntry 38 }

        mcmescConnDemuxShelf OBJECT-TYPE
                SYNTAX  ShelfInput
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The connected W4CD/UPSM shelf."
                ::= { mcmescEntry 39 }

        mcmescConnDemuxSlot OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The connected W4CD/UPSM slot."
                ::= { mcmescEntry 40 }

        mcmescConnDemuxPort OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The connected W4CD/UPSM port.
                         W4CD: 1=1470/1510, 2=1490/1530, 3=15501590/,
                               4=1570/1610, 5=EXP, 6=IN/OUT;
                         UPSM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
                               4=Link B Rx, 5=Local Tx, 6=Local Rx."
                ::= { mcmescEntry 41 }

       mcmescConnTxOcmShelf OBJECT-TYPE
                SYNTAX  ShelfInput
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The connected OCM shelf (from MCMESC's Link Tx)."
                ::= { mcmescEntry 42 }

       mcmescConnTxOcmSlot OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The connected OCM slot (from MCMESC's Link Tx)."
                ::= { mcmescEntry 43 }

        mcmescConnTxOcmPort OBJECT-TYPE
                SYNTAX  INTEGER { cpetx(3), cperx(4) }        
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The connected OCM port (from MCMESC's Link Tx).
                         3=OCM's CPE-Tx, 4=OCM's Rx. Only 4 is valid."
                ::= { mcmescEntry 44 }

        mcmescConnTxOcmShelfSlot    OBJECT-TYPE       
                SYNTAX  DisplayString (SIZE (0..10))
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Add a connection from MCMESC Link-Tx to an OCM CPE-Rx by
                         specifying the OCM's shelf and slot. The format is shlef,slot.
                         If either MCMESC Link-Tx or specified OCM CPE-Rx has already
                         had connection, an error will be returned. If the card 
                         specified by shelf,slot is not ocm type, an error will 
                         be returned.
                         A get on this variable will always return 0,0."
                ::= { mcmescEntry 45 }  

        mcmescConnTxOcmDelete OBJECT-TYPE       
                SYNTAX  INTEGER { other(1),  yes(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Delete a connection from MCMESC Link-Tx to an OCM CPE-Rx.
                         If MCMESC's Link-Tx has no connection with any OCM's CPE-Rx,
                         an error will be returned. 
                         A get on this variable will always return an other."
                ::= { mcmescEntry 46 }  

        mcmescConnRxOcmShelf OBJECT-TYPE
                SYNTAX  ShelfInput
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The connected OCM shelf (from MCMESC's Link Rx)."
                ::= { mcmescEntry 47 }

        mcmescConnRxOcmSlot OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The connected OCM slot (from MCMESC's Link Rx)."
                ::= { mcmescEntry 48 }

        mcmescConnRxOcmPort OBJECT-TYPE
                SYNTAX  INTEGER { cpetx(3), cperx(4) }        
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The connected OCM port (from MCMESC's Link Rx). 
                         3=OCM's CPE-Tx, 4=OCM's Rx. Only 3 is valid." 
                ::= { mcmescEntry 49 }

        mcmescConnRxOcmShelfSlot    OBJECT-TYPE       
                SYNTAX  DisplayString (SIZE (0..10))
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Add a connection from MCMESC Link-Rx to an OCM CPE-Tx by
                         specifying the OCM's shelf and slot. The format is shlef,slot.
                         If either MCMESC Link-Tx or specified OCM CPE-Rx has already
                         had connection, an error will be returned.  If the card
                         specified by shelf,slot is not ocm type, an error will
                         be returned.
                         A get on this variable will always return 0,0"
                ::= { mcmescEntry 50 }  

        mcmescConnRxOcmDelete   OBJECT-TYPE       
                SYNTAX  INTEGER { other(1), yes(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Delete a connection from MCMESC Link-Rx to an OCM CPE-Tx.
                         If MCMESC's Link-Rx has no connection with any OCM's CPE-Tx,
                         an error will be returned.
                         A get on this variable will always return an other."
                ::= { mcmescEntry 51 }  

        mcmescSetState     OBJECT-TYPE
                SYNTAX  INTEGER 
                        {
                            other(1),
                            resetWithCurrentConfiguration(2),
                            nearEndCardLoopback(3),
                            networkCardLoopback(4),
                            nearEndPort1Loopback(5),
                            nearEndPort2Loopback(6),
                            nearEndPort3Loopback(7),
                            nearEndPort4Loopback(8),
                            nearEndPort5Loopback(9),
                            nearEndPort6Loopback(10),
                            nearEndPort7Loopback(11),
                            nearEndPort8Loopback(12),
                            nearEndPort9Loopback(13),
                            nearEndPort10Loopback(14),
                            nearEndPort11Loopback(15),
                            nearEndPort12Loopback(16),
                            networkPort1Loopback(17),
                            networkPort2Loopback(18),
                            networkPort3Loopback(19),
                            networkPort4Loopback(20),
                            networkPort5Loopback(21),
                            networkPort6Loopback(22),
                            networkPort7Loopback(23),
                            networkPort8Loopback(24),
                            networkPort9Loopback(25),
                            networkPort10Loopback(26),
                            networkPort11Loopback(27),
                            networkPort12Loopback(28),
                            disableLoopback(29)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Instruct the mcmesc card to do either a reset or loopback.
                         A get on this will always return an other. If the card is
                         in self-test, an error will be returned. If the card is 
                         already in any loopback, and try to turn on another loopback, 
                         an error will be returned." 
                ::= { mcmescEntry 52 }


        mcmescLinkClrErrCount   OBJECT-TYPE
                SYNTAX  INTEGER 
                        {
                            other(1),
                            clearErrCount(2)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Instruct the mcmesc card to clear the bit-error count for 
                         link port. A get on this will always return an other." 
                ::= { mcmescEntry 53}

        mcmescPortNumber OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of MCMESC rows in the following table.  This 
                         number is automatically updated whenever a new row is 
                         added to the table below."
                ::= { mcmesc 7 }

        mcmescPortTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF McmescPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         MCMESC module's port."
                ::= { mcmesc 8 }

        mcmescPortEntry OBJECT-TYPE
                SYNTAX  McmescPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { mcmescPortCardLocation, mcmescPortCardShelf,
                          mcmescPortCardSlot,  mcmescPortIndex }
                ::= { mcmescPortTable 1 }

        McmescPortEntry ::=
                SEQUENCE
                {
                        mcmescPortCardLocation      CardLocation,
                        mcmescPortCardShelf         CardShelf,
                        mcmescPortCardSlot          INTEGER,
                        mcmescPortIndex             INTEGER,
                        mcmescPortSfpSerialNum      SfpSerialString,
                        mcmescPortConnectionState   INTEGER,
                        mcmescPortClrErrCount       INTEGER
                }

        mcmescPortCardLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Location of the MCMESC port.  Valid values are: Local in
                         the same chassis, or remote to this chassis."
                ::= { mcmescPortEntry 1 }

        mcmescPortCardShelf OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1..2."
                ::= { mcmescPortEntry 2 }

        mcmescPortCardSlot OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the Module is in.  Valid
                         values are: 1 to 17."
                ::= { mcmescPortEntry 3 }

        mcmescPortIndex OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "CPE port's index. Valid values are: 1 to 12."
                ::= { mcmescPortEntry 4 }

        mcmescPortSfpSerialNum OBJECT-TYPE
                SYNTAX  SfpSerialString 
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "CPE port's SFP serial number."
                ::= { mcmescPortEntry 5 }

        mcmescPortConnectionState OBJECT-TYPE
                SYNTAX  INTEGER { disabled(1), enabled(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "CPE port's connection status."
                ::= { mcmescPortEntry 6 }

        mcmescPortClrErrCount   OBJECT-TYPE
                SYNTAX  INTEGER 
                        {
                            other(1),
                            clearErrCount(2)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Instruct the mcmesc card to clear the bit-error count for 
                         a CPE port. A get on this will always return an other." 
                ::= { mcmescPortEntry 7}

        -- The elements in the topology subgroup of the configuration group


        topologyTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF TopologyEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the link topology between local and
                         remote cards"
                ::= { topology 1}

        topologyEntry   OBJECT-TYPE
                SYNTAX  TopologyEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { topologyNearEndCardShelf,     topologyNearEndCardSlot,
                          topologyNearEndCardPortIndex, topologyFarEndNodeCardShelf,
                          topologyFarEndNodeCardSlot,   topologyFarEndNodeCardPortIndex }
                ::= { topologyTable 1 }

        TopologyEntry     ::=
                SEQUENCE
                {
                        topologyNearEndCardShelf        CardShelf,
                        topologyNearEndCardSlot         INTEGER,
                        topologyNearEndCardPortIndex    PortIndex,
                        topologyNearEndCardType         CardType,
                        topologyFarEndChassisID         NodeName,
                        topologyFarEndSystemName        NodeName,
                        topologyFarEndNodeIpAddress     IpAddress,
                        topologyFarEndNodeCardShelf     CardShelf,
                        topologyFarEndNodeCardSlot      INTEGER,
                        topologyFarEndNodeCardPortIndex PortIndex,
                        topologyLinkStatus              INTEGER,
                        topologyFarEndNodeCardType      CardType
                }

        topologyNearEndCardShelf OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Shelf of the near end card."
                ::= { topologyEntry 1 }


        topologyNearEndCardSlot OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Slot of the near end card.  Input 0 will 
                         delete the topology link."
                ::= { topologyEntry 2 }

        topologyNearEndCardPortIndex OBJECT-TYPE
                SYNTAX  PortIndex
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Near end optical link port."
                ::= { topologyEntry 3 }

        topologyNearEndCardType OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Card type of the near end card."
                ::= { topologyEntry 4 }

        topologyFarEndChassisID OBJECT-TYPE
                SYNTAX  NodeName
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Chassis ID of the far end chassis. Part of manufacturing info"
                ::= { topologyEntry 5}

        topologyFarEndSystemName OBJECT-TYPE
                SYNTAX  NodeName
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Name of the far end node/chassis.  Not supported for
                         remote TMM masters."
                ::= { topologyEntry 6}

        topologyFarEndNodeIpAddress OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "IpAddress of the far end chassis. Not supported for
                         remote TMM masters."
                ::= { topologyEntry 7}

        topologyFarEndNodeCardShelf OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Shelf of the far end module"
                ::= { topologyEntry 8}

        topologyFarEndNodeCardSlot OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Slot of the far end module"
                ::= { topologyEntry 9}

        topologyFarEndNodeCardPortIndex OBJECT-TYPE
                SYNTAX  PortIndex
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Far end optical link port."
                ::= { topologyEntry 10}

        topologyLinkStatus OBJECT-TYPE
                SYNTAX  INTEGER { down(1), active(2), standby(3) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Status of the link to indicate if active or down"
                ::= { topologyEntry 11}

        topologyFarEndNodeCardType OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Card type of the far end card."
                ::= { topologyEntry 12 }

        topologyDiscover     OBJECT-TYPE
                SYNTAX  INTEGER { other(1), discoverTopology(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "An action to rediscover the complete topology
                         A get would alway return other(1)."
                ::= { topology 2 }

        -- The elements in the routing subgroup of the configuration group

        -- This table is no longer supported, instead user needs to use imnRoutingTable

        routingTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF RoutingEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents dynamic and static routing information"
                ::= { routing 1}

        routingEntry    OBJECT-TYPE
                SYNTAX  RoutingEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { routeIpDestAddress, routeLocalCCShelf, routeLocalCCSlot  }
                ::= { routingTable 1 }

        RoutingEntry    ::=
                SEQUENCE
                {
                        routeLocalCCShelf       CardShelf,
                        routeLocalCCSlot        INTEGER,
                        routeIpDestAddress      IpAddress,
                        routeDestType           INTEGER,
                        routeMode               INTEGER 
                }

        routeLocalCCShelf OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Shelf of the local CC card."
                ::= { routingEntry 1 }


        routeLocalCCSlot OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Slot of the local CC card."
                ::= { routingEntry 2 }


        routeIpDestAddress OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                       "Destination IP address. Not supported for
                        remote TMM masters."
                ::= { routingEntry 3}

 
        routeDestType   OBJECT-TYPE
                SYNTAX  INTEGER { externalRoute(1), internalRoute(2) }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Destination route type. External means destination is not part of LuxN network. 
                         Internal means destination is one of the LuxN node "
                ::= { routingEntry 4 }

        routeMode       OBJECT-TYPE
                SYNTAX  INTEGER { static(1), dynamic(2) }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Is the route added statically(manually) or dynamically(automatic) "
                ::= { routingEntry 5 }

        imnDynamicRoutingTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF ImnDynamicRoutingEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents IMN based dynamic routing information"
                ::= { routing 2}

        imnDynamicRoutingEntry OBJECT-TYPE
                SYNTAX  ImnDynamicRoutingEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { imnDynamicRouteIpDest}
                ::= { imnDynamicRoutingTable 1 }

        ImnDynamicRoutingEntry ::=
                SEQUENCE 
                {
                        imnDynamicRouteIpDest   IpAddress,
                        imnDynamicRouteIpMask   IpAddress,
                        imnDynamicRouteMetric   INTEGER,
                        imnDynamicRouteNextHop  IpAddress,
                        imnDynamicRouteSysName  DisplayString
                }

        imnDynamicRouteIpDest OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Destination IP address. Not supported for
                         remote TMM masters."
                ::= { imnDynamicRoutingEntry 1}

        imnDynamicRouteIpMask OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Destination's IP mask address. Not supported for
                        remote TMM masters."
                ::= { imnDynamicRoutingEntry 2}

        imnDynamicRouteMetric OBJECT-TYPE
                SYNTAX  INTEGER(1..15)
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Cost associated with this route."
                ::= { imnDynamicRoutingEntry 3}


        imnDynamicRouteNextHop OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Neighbour node of this route."
                ::= { imnDynamicRoutingEntry 4}

        imnDynamicRouteSysName OBJECT-TYPE
                SYNTAX  DisplayString(SIZE(0..20))
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Destination system name associated with route."
                ::= { imnDynamicRoutingEntry 5}

        imnRouteUpdateTimer OBJECT-TYPE
                SYNTAX  INTEGER (1..254)
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Time in seconds for the route table to get updated/propagated
                         Default value is 30 seconds."
                ::= { routing 3}

        imnRouteKeepAliveTimer OBJECT-TYPE
                SYNTAX  INTEGER (1..255)
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Time in seconds before neighbors enter unreachable state after communication
                         is lost. This value has to be greater than or equal to imnRouteUpdateTimer
                         Default value is 60 seconds" 
                ::= { routing 4}

        imnRouteUnReachableTimer OBJECT-TYPE
                SYNTAX  INTEGER (1..255)
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Time in seconds before Neighbors in unreachable state are deleted from 
                         the route table. This value has to greater than or equal to imnRouteUpdateTimer
                         Default value is  60 seconds" 
                ::= { routing 5}

        imnRouteMode    OBJECT-TYPE
                SYNTAX  INTEGER { disabled(1), enable(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Enable/Disable IMN functionality. Default is disabled" 
                ::= { routing 6}

        imnStaticRoutingTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF ImnStaticRoutingEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents IMN based static routing information"
                ::= { routing 7}

        imnStaticRoutingEntry  OBJECT-TYPE
                SYNTAX  ImnStaticRoutingEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { imnStaticRouteIpDest}
                ::= { imnStaticRoutingTable 1 }

        ImnStaticRoutingEntry ::=
                SEQUENCE 
                {
                        imnStaticRouteIpDest    IpAddress,
                        imnStaticRouteIpMask    IpAddress,
                        imnStaticRouteMetric    INTEGER
                }



        imnStaticRouteIpDest OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Destination IP address. Not supported for
                         remote TMM masters."
                ::= { imnStaticRoutingEntry 1}

        imnStaticRouteIpMask OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Destination's IP mask address. Not supported for
                         remote TMM masters."
                ::= { imnStaticRoutingEntry 2}

        imnStaticRouteMetric OBJECT-TYPE
                SYNTAX  INTEGER(1..15)
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Cost associated with this route."
                ::= { imnStaticRoutingEntry 3}

        imnRouteMaxMetric       OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Maximum acceptable metric count before the routes gets dropped.
                         Default value is 255. Ideally this value should be greater than
                         imnStaticRouteMetric" 
                ::= { routing 8}

        -- The elements in the ring subgroup of the configuration group

        ringNum         OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of ring configured in the list."
                ::= { ring 1 }


        ringTable       OBJECT-TYPE
                SYNTAX  SEQUENCE OF RingEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represent the ring information"
                ::= { ring 2}

        ringEntry       OBJECT-TYPE
                SYNTAX  RingEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { ringIndex  }
                ::= { ringTable 1 }

        RingEntry       ::=
                SEQUENCE
                {
                        ringIndex                   INTEGER,
                        ringID                      RingIdName,
                        ringPathID1                 PathIdName,
                        ringPathID2                 PathIdName,
                        ringPath1RemoteIP           IpAddress,
                        ringPath1RemoteChassisId    DisplayString,
                        ringPath2RemoteIP           IpAddress,
                        ringPath2RemoteChassisId    DisplayString
                }

        ringIndex       OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The ringIndex and also the index of the ring table."
                ::= { ringEntry 1 }


        ringID          OBJECT-TYPE
                SYNTAX  RingIdName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "RingID Name for UPSR.  Empty string will remove and deassociate 
                         the RingID with the PathIDs.  You always has one dummy entry for 
                         adding another ring."
                ::= { ringEntry 2 }


        ringPathID1     OBJECT-TYPE
                SYNTAX  PathIdName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "PathID 1 associate with this ring."
                ::= { ringEntry 3}

        ringPathID2     OBJECT-TYPE
                SYNTAX  PathIdName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "PathID 2 associate with this ring."
                ::= { ringEntry 4}

        ringPath1RemoteIP OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "IP Address of the neighbor node associated with path 1"
                ::= {  ringEntry 5 }

        ringPath1RemoteChassisId OBJECT-TYPE
                SYNTAX  DisplayString(SIZE(0..16))
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Chassis ID of the neighbor node associated with path 1"
                ::= { ringEntry 6}

        ringPath2RemoteIP OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "IP Address of the neighbor node associated with path 2"
                ::= {  ringEntry 7 }

        ringPath2RemoteChassisId OBJECT-TYPE
                SYNTAX  DisplayString(SIZE(0..16))
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Chassis ID of the neighbor node associated with path 2"
                ::= { ringEntry 8}

        -- The elements in the tap subgroup of the configuration group

        tapNumber       OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of TAP rows in the following table.  This number
                         is automatically updated whenever a new row is added
                         to the table below."
                ::= { tap 1 }

        tapTable        OBJECT-TYPE
                SYNTAX  SEQUENCE OF TapEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         TAP module"
                ::= { tap 2 }

        tapEntry        OBJECT-TYPE
                SYNTAX  TapEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { tapCardLocation, tapCardShelf, tapCardSlot }
                ::= { tapTable 1 }

        TapEntry        ::=
                SEQUENCE 
                {
                        tapCardLocation         CardLocation,
                        tapCardShelf            CardShelf,
                        tapCardSlot             INTEGER,
                        tapModelNum             DisplayString,
                        tapMfgDate              DateAndTime,
                        tapSerialNum            SerialString,
                        tapModelType            INTEGER,
                        tapName                 CardName,
                        tapFWVersionID          VersionString,
                        tapHWName               CardName,
                        tapPathID               PathIdName,
                        tapAdminState           INTEGER,
                        tapCleiNum              DisplayString,
                        tapNumPorts             INTEGER
                }

        tapCardLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Location of the module.  Valid values are: Local in
                         the same chassis, or remote to this chassis"
                ::= { tapEntry 1 }

        tapCardShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in."
                ::= { tapEntry 2 }

        tapCardSlot     OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the module is in.  The range
                         of valid values range from 1 through 17 depending on
                         the chassis type and the shelf the module is in.
                         To delete this card, set this variable to 0."
                ::= { tapEntry 3 }

        tapModelNum      OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Model number for module."  
                ::= { tapEntry 4 }

        tapMfgDate      OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of manufacturing of the module"
                ::= { tapEntry 5 }

        tapSerialNum    OBJECT-TYPE
                SYNTAX  SerialString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Serial number of the module."
                ::= { tapEntry 6 }

        tapModelType    OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Model type of the module"
                ::= { tapEntry 7 }

        tapName         OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "User configurable name of the module"
                ::= { tapEntry 8 }

        tapFWVersionID  OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The current version string of the FW code"
                ::= { tapEntry 9 }

        tapHWName       OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Display Hardware name of the module."
                ::= { tapEntry 10 }

        tapPathID       OBJECT-TYPE
                SYNTAX  PathIdName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Upsr Path ID name that this card is associated with.  
                         Set input equal NULL will remove the card off the path 
                         and also remove the path if there is no card left 
                         associate with that path."
                ::= { tapEntry 11 }

        tapAdminState     OBJECT-TYPE
                SYNTAX  INTEGER { disable(1), enable(2), na(3) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Administrative control over that TAP card. Default value is enable.
                         When disabled, no alarms/events gets generated."
                ::= {  tapEntry 12 }

        tapCleiNum      OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CLEI number for the module."
                ::= { tapEntry 13 }

        tapNumPorts    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total port numbers on each TAP card."
                ::= { tapEntry 14 }

        -- The elements in the voadm subgroup of the configuration group

        voadmNumber       OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of rows in the voadm table.  This number
                         is automatically updated whenever a new row is added
                         to the table below."
                ::= { voadm 1 }

        voadmTable        OBJECT-TYPE
                SYNTAX  SEQUENCE OF VoadmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         VOADM card"
                ::= { voadm 2 }

        voadmEntry        OBJECT-TYPE
                SYNTAX  VoadmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { voadmCardLocation, voadmCardShelf, voadmCardSlot }
                ::= { voadmTable 1 }

        VoadmEntry        ::=
                SEQUENCE 
                {
                        voadmCardLocation         CardLocation,
                        voadmCardShelf            CardShelf,
                        voadmCardSlot             INTEGER,
                        voadmSerialNum            SerialString,
                        voadmModelNum             DisplayString,
                        voadmHwName               DisplayString,
                        voadmHwVersionID          VersionString,
                        voadmMfgDate              DateAndTime,
                        voadmFwName               CardName,
                        voadmFwVersionID          VersionString,
                        voadmFwDate               DateAndTime,
                        voadmAdminState           INTEGER,
                        voadmModelType            INTEGER,
                        voadmName                 CardName,
                        voadmSetState             RebootType,
                        voadmPathID               PathIdName,
                        voadmCleiNum              DisplayString,
                        voadmActiveChannels       INTEGER,
                        voadmStartItu             INTEGER,
                        voadmEndItu               INTEGER,
                        voadmNumPorts             INTEGER
                }

        voadmCardLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Location of the module.  VOADM modules will
                         always be seen as local modules."
                ::= { voadmEntry 1 }

        voadmCardShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf where the module resides."
                ::= { voadmEntry 2 }

        voadmCardSlot     OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf where the module resides.  
                         The range of valid values range from 1 through 17 
                         depending on the chassis type and the shelf where 
                         the module is in.  To delete this card, set this 
                         variable to 0."
                ::= { voadmEntry 3 }

        voadmSerialNum    OBJECT-TYPE
                SYNTAX  SerialString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module serial number."
                ::= { voadmEntry 4 }

        voadmModelNum      OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module model number."
                ::= { voadmEntry 5 }

        voadmHwName      OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module hardware name." 
                ::= { voadmEntry 6 }

        voadmHwVersionID  OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module hardware version."
                ::= { voadmEntry 7 }

        voadmMfgDate      OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of manufacturing of the module"
                ::= { voadmEntry 8 }

        voadmFwName       OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module firmware name."
                ::= { voadmEntry 9 }

        voadmFwVersionID  OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Firmware version."
                ::= { voadmEntry 10 }

        voadmFwDate      OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Firmware release date and time."
                ::= { voadmEntry 11 }

        voadmAdminState     OBJECT-TYPE
                SYNTAX  INTEGER { disable(1), enable(2), na(3) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Administrative control for the module. Default 
                         value is enable. When disabled, no alarms/events are
                         generated for the module."
                ::= {  voadmEntry 12}

        voadmModelType    OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Model type of the module."
                ::= { voadmEntry 13 }

        voadmName         OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "User configurable name of the module."
                ::= { voadmEntry 14 }

        voadmSetState     OBJECT-TYPE
                SYNTAX  RebootType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Instruct the module to do a warmboot. A get on this will
                         always return 'other'."
                ::= { voadmEntry 15 }

        voadmPathID       OBJECT-TYPE
                SYNTAX  PathIdName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Path ID name associated with the module. Set input 
                         equal to NULL will remove the card off the path 
                         and also remove the path if no other modules are 
                         associated with that path."
                ::= { voadmEntry 16 }

        voadmCleiNum      OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CLEI number of the module."
                ::= { voadmEntry 17 }

        voadmActiveChannels OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Number of active channels connected to the module. 
                         The allowed inpu range depends on the module type:
                           MD100-5      1 to  5
                           MD100-10     1 to 10"
                ::= { voadmEntry 18 }

        voadmStartItu      OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "First ITU channel supported by the module."
                ::= { voadmEntry 19 }

        voadmEndItu      OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Last ITU channel supported by the module."
                ::= { voadmEntry 20 }

        voadmNumPorts    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total port numbers on each VOADM card."
                ::= { voadmEntry 21 }

        voadmPortTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF VoadmPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each set
                         of ports on the module.  Ports are divided into two
                         sets: mux ports and demux ports."
                ::= { voadm 3 }

        voadmPortEntry    OBJECT-TYPE
                SYNTAX  VoadmPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { voadmPortCardLocation, voadmPortCardShelf, voadmPortCardSlot, voadmPortType }
                ::= { voadmPortTable 1 }

        VoadmPortEntry    ::=
                SEQUENCE 
                {
                        voadmPortCardLocation           CardLocation,
                        voadmPortCardShelf              CardShelf,
                        voadmPortCardSlot               SlotInput,
                        voadmPortType                   INTEGER,
                        voadmPortMode                   INTEGER,
                        voadmPortSetPoint               DisplayString,
                        voadmPortMinChanInputPower      DisplayString,
                        voadmPortMinChanOutputPower     DisplayString,
                        voadmPortMaxChanOutputPower     DisplayString,
                        voadmPortToleranceUpperBound    DisplayString,
                        voadmPortToleranceLowerBound    DisplayString,
                        voadmPortTotalInputPower        DisplayString,
                        voadmPortPerChanInputPower      DisplayString,
                        voadmPortTotalOutputPower       DisplayString,
                        voadmPortPerChanOutputPower     DisplayString,
                        voadmPortMeasuredAtten          DisplayString,
                        voadmPortAvgInsertLoss          DisplayString,
                        voadmPortAvgExpressLoss         DisplayString
                }

        voadmPortCardLocation           OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Location of the module.  VOADM modules will
                         always be seen as local modules."
                ::= { voadmPortEntry 1 }

        voadmPortCardShelf              OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The shelf where the module resides."
                ::= { voadmPortEntry 2 }

        voadmPortCardSlot               OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf where the module resides."
                ::= { voadmPortEntry 3 }

        voadmPortType                  OBJECT-TYPE
                SYNTAX  INTEGER  { mux(1), demux(2) }
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Port type for which the below values apply."
                ::= { voadmPortEntry 4 }

        voadmPortMode                   OBJECT-TYPE
                SYNTAX  INTEGER { fixed-attentuation(1), fixed-power(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Port mode.  This value will not be stored in the 
                         database until the port set point is set."
                ::= { voadmPortEntry 5 }

        voadmPortSetPoint               OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-write 
                STATUS  mandatory
                DESCRIPTION
                        "Port set point.  Valid range depends on the port mode:
                           Fixed Attentuation   0.0 to 20.0 (dB)
                           Fixed Power        -30.0 to 15.0 (dBm)
                           
                         Untils are omitted when setting."
                ::= { voadmPortEntry 6 }

        voadmPortMinChanInputPower      OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Minimum input power for each active channel. Valid range
                         for Mux and Demux ports is -30.0 to 15.0 dBm"
                ::= { voadmPortEntry 7 }

        voadmPortMinChanOutputPower     OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Minimum output power for each active channel.  Valid range
                         depends on port:
                            Mux     -20.0 to 15.0 dBm
                            Demux   -30.0 to -8.0 dBm."
                ::= { voadmPortEntry 8 }

        voadmPortMaxChanOutputPower     OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Maximum output power for each active channel.  Valid range
                         depends on port:
                            Mux     -20.0 to 15.0 dBm
                            Demux   -30.0 to -8.0 dBm."
                ::= { voadmPortEntry 9 }

        voadmPortToleranceUpperBound    OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Upper bound for allowable power/attenuation error.
                         Valid range is 0.2 to 10.0 dB."
                ::= { voadmPortEntry 10}

        voadmPortToleranceLowerBound    OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Lower bound for allowable power/attenuation error.
                         Valid range is 0.2 to 10.0 dB."
                ::= { voadmPortEntry 11 }

        voadmPortTotalInputPower        OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Power reading from input detector.  Valid range:
                            -30 to 15 dBm"
                ::= { voadmPortEntry 12 }

        voadmPortPerChanInputPower      OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total input power divided by number of active 
                         channels.  Valid range:
                            -30 to 15 dBm"
                ::= { voadmPortEntry 13 }

        voadmPortTotalOutputPower       OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Power reading from output detector.  Valid range:
                            -30 to 15 dBm"
                ::= { voadmPortEntry 14 }

        voadmPortPerChanOutputPower     OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total output power divided by number of active
                         channels.  Valid range:
                            -30 to 15 dBm"
                ::= { voadmPortEntry 15 }

        voadmPortMeasuredAtten          OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Difference between total input power and total
                         output power."
                ::= { voadmPortEntry 16 }

        voadmPortAvgInsertLoss          OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Average insertion loss for ports."
                ::= { voadmPortEntry 17 }

        voadmPortAvgExpressLoss         OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Average express los for ports."
                ::= { voadmPortEntry 18 }

        -- ZMS config synchronization elements

        zmsConfigSyncExists OBJECT-TYPE
            SYNTAX Boolean
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Indicates whether or not there exists records to be
                sent to the ZMS config synch manager for changes
                that have been made by CLI/HTTP to the data base."
            ::= { zmsConfigSync 1 }

        
        zmsConfigSyncOverflow OBJECT-TYPE
            SYNTAX Boolean
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Indicates whether or not the device had to discard
                update data base records due to resource constraints.
                If TRUE, traps will be sent to the ZMS Config Synch
                Manager indicating a download of the entire data
                base is required."
            ::= { zmsConfigSync 2 }

        
        zmsConfigSyncPriority OBJECT-TYPE
            SYNTAX INTEGER
                {
                none(1),
                low(2),
                medium(3),
                high(4)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Indicates the highest priority configuration synchronization trap 
                outstanding. This flag is set to none at boot time and whenever a file
                of synchronization changes has been sent to ZMS. If a parameter change
                has been made to either the same or lower prioirty, the device does
                not have to send a change notification to ZMS. Higher priority
                fields must immediately cause traps to be sent to ZMS."
            ::= { zmsConfigSync 3 }

        
        zmsConfigSyncAction OBJECT-TYPE
            SYNTAX INTEGER
                {
                noAction(1),
                createList(2),
                createFullList(3),
                createFullListWithAlarms(4),
                createAlarmsList(5)
                }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "Used by ZMS when it wants to create a list
                of config synch records. It must first write the
                filename expected and then set the action. The
                create list action allows the device to determine
                whether the complete database (synchoverflow 
                occured) needs to be sent or only those records
                that have been modified. create full list 
                specifies that ZMS would like to receive the
                complete database."
            ::= { zmsConfigSync 4 }

        
        zmsConfigSyncFileName OBJECT-TYPE
            SYNTAX ZmsFileName
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "File Name to be used when creating the config
                synch records."
            ::= { zmsConfigSync 5 }

        
        zmsConfigSyncStatus OBJECT-TYPE
            SYNTAX INTEGER
                {
                syncComplete(1),
                syncPending(2),
                syncError(3),
                syncInitializing(4)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Used by Config Sync Acgent when processing a request
                to create a list of config synch records."
            ::= { zmsConfigSync 6 }

        
        zmsConfigSyncUserName OBJECT-TYPE
            SYNTAX ZmsAdminString
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "User Name to be used when sending the config
                synch records.
                
                When read, the last user name is returned. "
            ::= { zmsConfigSync 7 }

        
        zmsConfigSyncUserPassword OBJECT-TYPE
            SYNTAX ZmsAdminString
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "Password to be used when sending the config
                synch records. For use in FTP authentication.
                
                When read, always returns the NULL string"
            ::= { zmsConfigSync 8 }

       zmsIpAddress OBJECT-TYPE
            SYNTAX IpAddress
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "This is the ZMS IP address for which configuration synchronization 
                messages and any other special handling is performed."
            ::= { zmsConfigSync 9 }

        -- The elements in the dmm subgroup of the configuration group

        dmmNumber       OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of rows in the dmm table.  This number
                         is automatically updated whenever a new row is added
                         to the table below."
                ::= { dmm 1 }

        dmmTable        OBJECT-TYPE
                SYNTAX  SEQUENCE OF DmmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         DMM card"
                ::= { dmm 2 }

        dmmEntry        OBJECT-TYPE
                SYNTAX  DmmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { dmmCardLocation, dmmCardShelf, dmmCardSlot }
                ::= { dmmTable 1 }

        DmmEntry        ::=
                SEQUENCE 
                {
                        dmmCardLocation         CardLocation,
                        dmmCardShelf            CardShelf,
                        dmmCardSlot             INTEGER,
                        dmmSerialNum            SerialString,
                        dmmModelNum             DisplayString,
                        dmmHwName               DisplayString,
                        dmmHwVersionID          VersionString,
                        dmmMfgDate              DateAndTime,
                        dmmFwName               CardName,
                        dmmFwVersionID          VersionString,
                        dmmFwDate               DateAndTime,
                        dmmAdminState           INTEGER,
                        dmmModelType            INTEGER,
                        dmmName                 CardName,
                        dmmSetState             INTEGER,
                        dmmPathID               PathIdName,
                        dmmLinkName             LinkName,
                        dmmCleiNum              DisplayString,
                        dmmNumPorts             INTEGER,
                        dmmFpgaRev              INTEGER
                }

        dmmCardLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Location of the module."
                ::= { dmmEntry 1 }

        dmmCardShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf where the module resides."
                ::= { dmmEntry 2 }

        dmmCardSlot     OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf where the module resides.  
                         The range of valid values range from 1 through 17 
                         depending on the chassis type and the shelf where 
                         the module is in.  To delete this card, set this 
                         variable to 0."
                ::= { dmmEntry 3 }

        dmmSerialNum    OBJECT-TYPE
                SYNTAX  SerialString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module serial number."
                ::= { dmmEntry 4 }

        dmmModelNum     OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module model number."
                ::= { dmmEntry 5 }

        dmmHwName       OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module hardware name." 
                ::= { dmmEntry 6 }

        dmmHwVersionID  OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module hardware version."
                ::= { dmmEntry 7 }

        dmmMfgDate      OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of manufacturing of the module"
                ::= { dmmEntry 8 }

        dmmFwName       OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module firmware name."
                ::= { dmmEntry 9 }

        dmmFwVersionID  OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Firmware version."
                ::= { dmmEntry 10 }

        dmmFwDate       OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Firmware release date and time."
                ::= { dmmEntry 11 }

        dmmAdminState   OBJECT-TYPE
                SYNTAX  INTEGER { disable(1), enable(2), na(3) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Administrative control for the module. Default 
                         value is enable. When disabled, no alarms/events are
                         generated for the module."
                ::= {  dmmEntry 12}

        dmmModelType    OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Model type of the module."
                ::= { dmmEntry 13 }

        dmmName         OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "User configurable name of the module."
                ::= { dmmEntry 14 }

        dmmSetState     OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            other(1), 
                            warmboot(2),
                            enableLinkLoopback(3),
                            enablePort1Loopback(4),
                            enablePort2Loopback(5),
                            disableloopback(6)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Instruct the module to do a warmboot. A get on this will
                         always return 'other'."
                ::= { dmmEntry 15 }

        dmmPathID       OBJECT-TYPE
                SYNTAX  PathIdName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Path ID name associated with the module. Set input 
                         equal to NULL will remove the card off the path 
                         and also remove the path if no other modules are 
                         associated with that path."
                ::= { dmmEntry 16 }

        dmmLinkName     OBJECT-TYPE
                SYNTAX  LinkName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Link name for fiber between the local and the
                         remote card."
                ::= { dmmEntry 17 }

        dmmCleiNum      OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CLEI number of the module."
                ::= { dmmEntry 18 }

        dmmNumPorts    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total port numbers on each DMM card."
                ::= { dmmEntry 19 }

        dmmFpgaRev    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "FPGA revision for the module."
                ::= { dmmEntry 20 }

        dmmPortTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF DmmPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each set
                         of ports on the module.  Ports are divided into two
                         sets: mux ports and demux ports."
                ::= { dmm 3 }

        dmmPortEntry    OBJECT-TYPE
                SYNTAX  DmmPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { dmmPortLocation, dmmPortShelf, dmmPortSlot, dmmPortIndex }
                ::= { dmmPortTable 1 }

        DmmPortEntry    ::=
                SEQUENCE 
                {
                        dmmPortLocation               CardLocation,
                        dmmPortShelf                  CardShelf,
                        dmmPortSlot                   SlotInput,
                        dmmPortIndex                  INTEGER,
                        dmmPortLineRate               INTEGER,
                        dmmPortAutoDisable            INTEGER,
                        dmmPortMode                   INTEGER,
                        dmmPortItu                    INTEGER,
                        dmmPortWavelength             DisplayString,
                        dmmPortRxPower                DisplayString,
                        dmmPortTxState                INTEGER,
                        dmmPortTxReach                INTEGER,
                        dmmPortSfpSerialNumber        DisplayString,
                        dmmPortSfpConnectorType       INTEGER
                }

        dmmPortLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Location of the module."
                ::= { dmmPortEntry 1 }

        dmmPortShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The shelf where the module resides."
                ::= { dmmPortEntry 2 }

        dmmPortSlot     OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf where the module resides."
                ::= { dmmPortEntry 3 }

        dmmPortIndex    OBJECT-TYPE
                SYNTAX  INTEGER  { link(1), port1(2), port2(3) }
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Port for which the below values apply."
                ::= { dmmPortEntry 4 }

        dmmPortLineRate OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            notapplicable(0),
                            gbEthernet(4),
                            fibreChannel(5),
                            disabled(255)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Port line rate.  Valid only for ports 1 and 2."
                ::= { dmmPortEntry 5 }

        dmmPortAutoDisable  OBJECT-TYPE
                SYNTAX  INTEGER { notapplicable(0), enable(1), disable(2), farEndEnable(3) }
                ACCESS  read-write 
                STATUS  mandatory
                DESCRIPTION
                        "Flag to enable/disable the CPE link when a fault
                         is detected.  Far end CPE disable is identical to normal
                         CPE disable with the added feature that the local
                         CPE Tx will be disabled if a loss of light condition
                         is detected on the remote CPE Rx."
                ::= { dmmPortEntry 6 }

        dmmPortMode     OBJECT-TYPE
                SYNTAX  INTEGER { disabled(1), enabled(2), loopback(3) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port mode."
                ::= { dmmPortEntry 7 }

        dmmPortItu      OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port ITU number.  The ITU number is determined
                         from the SFP wavelength."
                ::= { dmmPortEntry 8 }

        dmmPortWavelength   OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Wavelength from port SFP."
                ::= { dmmPortEntry 9 }

        dmmPortRxPower  OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Receive power reported by port SFP."
                ::= { dmmPortEntry 10}

        dmmPortTxState  OBJECT-TYPE
                SYNTAX  INTEGER  { on(1), off(2) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "State of port SFP transmitter."
                ::= { dmmPortEntry 11 }

        dmmPortTxReach  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Optical reach in meters reported by port SFP."
                ::= { dmmPortEntry 12 }

        dmmPortSfpSerialNumber  OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port SFP serial number."
                ::= { dmmPortEntry 13 }

        dmmPortSfpConnectorType  OBJECT-TYPE
                SYNTAX  INTEGER
                {
                    na(0),
                    unknown(1),
                    sc(2),
                    fc_copper1(3),
                    fc_capper2(4),
                    bnc(5),
                    fc_coaxial(6),
                    fiberjack(7),
                    lc(8),
                    mtrj(9),
                    mu(10),
                    sg(11),
                    optpigtail(12),
                    hssdcii(33),
                    copper(34)
                }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port SFP connector type."
                ::= { dmmPortEntry 14 }


        dmmConnTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF DmmConnEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each set
                         of ports on the module.  Ports are divided into two
                         sets: mux ports and demux ports."
                ::= { dmm 4 }

        dmmConnEntry    OBJECT-TYPE
                SYNTAX  DmmConnEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { dmmConnCardLocation, dmmConnCardShelf, dmmConnCardSlot, dmmConnCardPortType }
                ::= { dmmConnTable 1 }

        DmmConnEntry    ::=
                SEQUENCE 
                {
                        dmmConnCardLocation           CardLocation,
                        dmmConnCardShelf              CardShelf,
                        dmmConnCardSlot               SlotInput,
                        dmmConnCardPortType           INTEGER,
                        dmmConnCardType               CardType,
                        dmmConnLocation               CardLocation,
                        dmmConnShelf                  ShelfInput,
                        dmmConnSlot                   SlotInput,
                        dmmConnPort                   INTEGER
                }

        dmmConnCardLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Location of the module."
                ::= { dmmConnEntry 1 }

        dmmConnCardShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The shelf where the module resides."
                ::= { dmmConnEntry 2 }

        dmmConnCardSlot OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf where the module resides."
                ::= { dmmConnEntry 3 }

        dmmConnCardPortType OBJECT-TYPE
                SYNTAX  INTEGER  { port1tx(1), port1rx(2), port2tx(3), port2rx(4), linktx(5), linkrx(6) }
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Port for which the below values apply."
                ::= { dmmConnEntry 4 }

        dmmConnCardType OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module type connected to port."
                ::= { dmmConnEntry 5 }

        dmmConnLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The chassis location of the card connected to
                         this port."
                ::= { dmmConnEntry 6 }

        dmmConnShelf    OBJECT-TYPE
                SYNTAX  ShelfInput
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf of the card connected to this port"
                ::= { dmmConnEntry 7 }

        dmmConnSlot     OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The slot of the card connected to this port"
                ::= { dmmConnEntry 8 }

        dmmConnPort     OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Conn port for the DMM's port. Possible values based on 
                         card types that can be connected to are:
                         FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local  Tx
                               4=Local  Rx, 5=Conn B Tx, 6=Conn B Rx
                         OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1/MCMESC: 1=Link Tx, 2=Link Rx 
                         OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN
                         OSAM: 1=IN, 2=OUT
                         W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT
                         W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT
                         UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
                                    4=Link B Rx, 5=Local Tx, 6=Local Rx.
                         Entry supported by all Mux modules except MD100-40 & BD4."
                ::= { dmmConnEntry 9 }

        -- The elements in the ocm10gf subgroup of the configuration group

        ocm10gfNumber       OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of rows in the ocm10gf table.  This number
                         is automatically updated whenever a new row is added
                         to the table below."
                ::= { ocm10gf 1 }

        ocm10gfTable        OBJECT-TYPE
                SYNTAX  SEQUENCE OF Ocm10gfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         OCM10GF card"
                ::= { ocm10gf 2 }

        ocm10gfEntry        OBJECT-TYPE
                SYNTAX  Ocm10gfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { ocm10gfCardLocation, ocm10gfCardShelf, ocm10gfCardSlot }
                ::= { ocm10gfTable 1 }

        Ocm10gfEntry        ::=
                SEQUENCE 
                {
                        ocm10gfCardLocation         CardLocation,
                        ocm10gfCardShelf            CardShelf,
                        ocm10gfCardSlot             INTEGER,
                        ocm10gfSerialNum            SerialString,
                        ocm10gfModelNum             DisplayString,
                        ocm10gfHwName               DisplayString,
                        ocm10gfHwVersionID          VersionString,
                        ocm10gfMfgDate              DateAndTime,
                        ocm10gfFwName               CardName,
                        ocm10gfFwVersionID          VersionString,
                        ocm10gfFwDate               DateAndTime,
                        ocm10gfModelType            INTEGER,
                        ocm10gfName                 CardName,
                        ocm10gfLineRate             INTEGER,
                        ocm10gfAutoDisable          INTEGER,
                        ocm10gfLinkName             LinkName,
                        ocm10gfPathID               PathIdName,
                        ocm10gfAdminState           INTEGER,
                        ocm10gfSetState             INTEGER,
                        ocm10gfCleiNum              DisplayString,
                        ocm10gfNumPorts             INTEGER,
                        ocm10gfFpgaRev              INTEGER
                }

        ocm10gfCardLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Location of the module."
                ::= { ocm10gfEntry 1 }

        ocm10gfCardShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf where the module resides."
                ::= { ocm10gfEntry 2 }

        ocm10gfCardSlot     OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf where the module resides.  
                         The range of valid values range from 1 through 17 
                         depending on the chassis type and the shelf where 
                         the module is in.  To delete this card, set this 
                         variable to 0."
                ::= { ocm10gfEntry 3 }

        ocm10gfSerialNum    OBJECT-TYPE
                SYNTAX  SerialString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module serial number."
                ::= { ocm10gfEntry 4 }

        ocm10gfModelNum     OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module model number."
                ::= { ocm10gfEntry 5 }

        ocm10gfHwName       OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module hardware name." 
                ::= { ocm10gfEntry 6 }

        ocm10gfHwVersionID  OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module hardware version."
                ::= { ocm10gfEntry 7 }

        ocm10gfMfgDate      OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of manufacturing of the module"
                ::= { ocm10gfEntry 8 }

        ocm10gfFwName       OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module firmware name."
                ::= { ocm10gfEntry 9 }

        ocm10gfFwVersionID  OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Firmware version."
                ::= { ocm10gfEntry 10 }

        ocm10gfFwDate       OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Firmware release date and time."
                ::= { ocm10gfEntry 11 }

        ocm10gfModelType    OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Model type of the module."
                ::= { ocm10gfEntry 12 }

        ocm10gfName         OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "User configurable name of the module."
                ::= { ocm10gfEntry 13 }

        ocm10gfLineRate OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            gbE10(9),
                            fc10(11),
                            oc192nt(12),
                            oc192tr(13),
                            disabled(255)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Port line rate.  Valid only for ports 1 and 2."
                ::= { ocm10gfEntry 14 }

        ocm10gfAutoDisable  OBJECT-TYPE
                SYNTAX  INTEGER { enable(1), disable(2) }
                ACCESS  read-write 
                STATUS  mandatory
                DESCRIPTION
                        "Flag to enable/disable the CPE link when a fault
                         is detected.  Far end CPE disable is identical to normal
                         CPE disable with the added feature that the local
                         CPE Tx will be disabled if a loss of light condition
                         is detected on the remote CPE Rx."
                ::= { ocm10gfEntry 15 }

        ocm10gfLinkName     OBJECT-TYPE
                SYNTAX  LinkName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Link name for fiber between the local and the
                         remote card."
                ::= { ocm10gfEntry 16 }

        ocm10gfPathID       OBJECT-TYPE
                SYNTAX  PathIdName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Path ID name associated with the module. Set input 
                         equal to NULL will remove the card off the path 
                         and also remove the path if no other modules are 
                         associated with that path."
                ::= { ocm10gfEntry 17 }

        ocm10gfAdminState   OBJECT-TYPE
                SYNTAX  INTEGER { disable(1), enable(2), na(3) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Administrative control for the module. Default 
                         value is enable. When disabled, no alarms/events are
                         generated for the module."
                ::= {  ocm10gfEntry 18}

        ocm10gfSetState     OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            other(1), 
                            warmboot(2),
                            enableLinkLoopback(3),
                            enableCpeLoopback(4),
                            disableloopback(5)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Instruct the module to do a warmboot. A get on this will
                         always return 'other'."
                ::= { ocm10gfEntry 19 }

        ocm10gfCleiNum      OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CLEI number of the module."
                ::= { ocm10gfEntry 20 }

        ocm10gfNumPorts    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total port numbers on each OCM10GF card."
                ::= { ocm10gfEntry 21 }

        ocm10gfFpgaRev    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "FPGA revision for the module."
                ::= { ocm10gfEntry 22 }

        ocm10gfPortTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF Ocm10gfPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each set
                         of ports on the module.  Ports are divided into two
                         sets: mux ports and demux ports."
                ::= { ocm10gf 3 }

        ocm10gfPortEntry    OBJECT-TYPE
                SYNTAX  Ocm10gfPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { ocm10gfPortLocation, ocm10gfPortShelf, ocm10gfPortSlot, ocm10gfPortIndex }
                ::= { ocm10gfPortTable 1 }

        Ocm10gfPortEntry    ::=
                SEQUENCE 
                {
                        ocm10gfPortLocation               CardLocation,
                        ocm10gfPortShelf                  CardShelf,
                        ocm10gfPortSlot                   SlotInput,
                        ocm10gfPortIndex                  INTEGER,
                        ocm10gfPortMode                   INTEGER,
                        ocm10gfPortWavelength             DisplayString,
                        ocm10gfPortRxPower                DisplayString,
                        ocm10gfPortTxState                INTEGER,
                        ocm10gfPortTxReach                INTEGER,
                        ocm10gfPortXfpSerialNumber        DisplayString
                }

        ocm10gfPortLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Location of the module."
                ::= { ocm10gfPortEntry 1 }

        ocm10gfPortShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The shelf where the module resides."
                ::= { ocm10gfPortEntry 2 }

        ocm10gfPortSlot     OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf where the module resides."
                ::= { ocm10gfPortEntry 3 }

        ocm10gfPortIndex    OBJECT-TYPE
                SYNTAX  INTEGER  { link(1), cpe(2) }
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Port for which the below values apply."
                ::= { ocm10gfPortEntry 4 }

        ocm10gfPortMode     OBJECT-TYPE
                SYNTAX  INTEGER { disabled(1), enabled(2), loopback(3) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port mode."
                ::= { ocm10gfPortEntry 5 }

        ocm10gfPortWavelength   OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Wavelength from port SFP."
                ::= { ocm10gfPortEntry 6 }

        ocm10gfPortRxPower  OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Receive power reported by port SFP."
                ::= { ocm10gfPortEntry 7 }

        ocm10gfPortTxState  OBJECT-TYPE
                SYNTAX  INTEGER  { na(0), on(1), off(2) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "State of port SFP transmitter."
                ::= { ocm10gfPortEntry 8 }

        ocm10gfPortTxReach  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Optical reach in meters reported by port SFP."
                ::= { ocm10gfPortEntry 9 }

        ocm10gfPortXfpSerialNumber  OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port SFP serial number."
                ::= { ocm10gfPortEntry 10 }

        ocm10gfConnTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF Ocm10gfConnEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each set
                         of ports on the module.  Ports are divided into two
                         sets: mux ports and demux ports."
                ::= { ocm10gf 4 }

        ocm10gfConnEntry    OBJECT-TYPE
                SYNTAX  Ocm10gfConnEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { ocm10gfConnCardLocation, ocm10gfConnCardShelf, ocm10gfConnCardSlot, ocm10gfConnCardPortType }
                ::= { ocm10gfConnTable 1 }

        Ocm10gfConnEntry    ::=
                SEQUENCE 
                {
                        ocm10gfConnCardLocation           CardLocation,
                        ocm10gfConnCardShelf              CardShelf,
                        ocm10gfConnCardSlot               SlotInput,
                        ocm10gfConnCardPortType           INTEGER,
                        ocm10gfConnCardType               CardType,
                        ocm10gfConnLocation               CardLocation,
                        ocm10gfConnShelf                  ShelfInput,
                        ocm10gfConnSlot                   SlotInput,
                        ocm10gfConnPort                   INTEGER
                }

        ocm10gfConnCardLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Location of the module."
                ::= { ocm10gfConnEntry 1 }

        ocm10gfConnCardShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The shelf where the module resides."
                ::= { ocm10gfConnEntry 2 }

        ocm10gfConnCardSlot OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf where the module resides."
                ::= { ocm10gfConnEntry 3 }

        ocm10gfConnCardPortType OBJECT-TYPE
                SYNTAX  INTEGER  { linktx(1), linkrx(2), cpetx(3), cperx(4) }
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Port for which the below values apply."
                ::= { ocm10gfConnEntry 4 }

        ocm10gfConnCardType OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module type connected to port."
                ::= { ocm10gfConnEntry 5 }

        ocm10gfConnLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The chassis location of the card connected to
                         this port."
                ::= { ocm10gfConnEntry 6 }

        ocm10gfConnShelf    OBJECT-TYPE
                SYNTAX  ShelfInput
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf of the card connected to this port"
                ::= { ocm10gfConnEntry 7 }

        ocm10gfConnSlot     OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The slot of the card connected to this port"
                ::= { ocm10gfConnEntry 8 }

        ocm10gfConnPort     OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Conn port for the OCM10GF's port. Possible values based on 
                         card types that can be connected to are:
                         FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local  Tx
                               4=Local  Rx, 5=Conn B Tx, 6=Conn B Rx
                         OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1/MCMESC: 1=Link Tx, 2=Link Rx 
                         OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN
                         OSAM: 1=IN, 2=OUT
                         W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT
                         W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT
                         UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
                                    4=Link B Rx, 5=Local Tx, 6=Local Rx.
                         Entry supported by all Mux modules except MD100-40 & BD4."
                ::= { ocm10gfConnEntry 9 }

        -- The elements in the fc8g subgroup of the configuration group

        fc8gNumber       OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of rows in the fc8g table.  This number
                         is automatically updated whenever a new row is added
                         to the table below."
                ::= { fc8g 1 }

        fc8gTable        OBJECT-TYPE
                SYNTAX  SEQUENCE OF Fc8gEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         FC8G card"
                ::= { fc8g 2 }

        fc8gEntry        OBJECT-TYPE
                SYNTAX  Fc8gEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { fc8gCardLocation, fc8gCardShelf, fc8gCardSlot }
                ::= { fc8gTable 1 }

        Fc8gEntry        ::=
                SEQUENCE 
                {
                        fc8gCardLocation         INTEGER,
                        fc8gCardShelf            CardShelf,
                        fc8gCardSlot             INTEGER,
                        fc8gSerialNum            SerialString,
                        fc8gModelNum             DisplayString,
                        fc8gHwName               DisplayString,
                        fc8gHwVersionID          VersionString,
                        fc8gMfgDate              DateAndTime,
                        fc8gFwName               CardName,
                        fc8gFwVersionID          VersionString,
                        fc8gFwDate               DateAndTime,
                        fc8gModelType            INTEGER,
                        fc8gName                 CardName,
                        fc8gLink1DataRate        INTEGER,
                        fc8gCpe1AutoDisable      INTEGER,
                        fc8gCpe1LaserEnabled     INTEGER,
                        fc8gLink1LaserEnabled    INTEGER,
                        fc8gLink2DataRate        INTEGER,
                        fc8gCpe2AutoDisable      INTEGER,
                        fc8gCpe2LaserEnabled     INTEGER,
                        fc8gLink2LaserEnabled    INTEGER,
                        fc8gAdminState           INTEGER,
                        fc8gSetState             INTEGER
                }

        fc8gCardLocation OBJECT-TYPE
                SYNTAX  INTEGER { local(1) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Location of the module."
                ::= { fc8gEntry 1 }

        fc8gCardShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf where the module resides."
                ::= { fc8gEntry 2 }

        fc8gCardSlot     OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf where the module resides.  
                         The range of valid values range from 1 through 17 
                         depending on the chassis type and the shelf where 
                         the module is in.  To delete this card, set this 
                         variable to 0."
                ::= { fc8gEntry 3 }

        fc8gSerialNum    OBJECT-TYPE
                SYNTAX  SerialString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module serial number."
                ::= { fc8gEntry 4 }

        fc8gModelNum     OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module model number."
                ::= { fc8gEntry 5 }

        fc8gHwName       OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module hardware name." 
                ::= { fc8gEntry 6 }

        fc8gHwVersionID  OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module hardware version."
                ::= { fc8gEntry 7 }

        fc8gMfgDate      OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of manufacturing of the module"
                ::= { fc8gEntry 8 }

        fc8gFwName       OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module firmware name."
                ::= { fc8gEntry 9 }

        fc8gFwVersionID  OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Firmware version."
                ::= { fc8gEntry 10 }

        fc8gFwDate       OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Firmware release date and time."
                ::= { fc8gEntry 11 }

        fc8gModelType    OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Model type of the module."
                ::= { fc8gEntry 12 }

        fc8gName         OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "User configurable name of the module."
                ::= { fc8gEntry 13 }

        fc8gLink1DataRate OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            dr8G(1),
                            dr4G(2),
                            dr2G(3),
                            dr1G(4)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Link 1 Data rate."
                ::= { fc8gEntry 14 }

        fc8gCpe1AutoDisable  OBJECT-TYPE
                SYNTAX  INTEGER { enable(1), disable(2) }
                ACCESS  read-write 
                STATUS  mandatory
                DESCRIPTION
                        "Flag to enable/disable automatic CPE disable for Link 1."
                ::= { fc8gEntry 15 }

        fc8gCpe1LaserEnabled OBJECT-TYPE
                SYNTAX  INTEGER { enable(1), disable(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Flag to enable/disable the CPE laser for Link 1."
                ::= { fc8gEntry 16 }

        fc8gLink1LaserEnabled OBJECT-TYPE
                SYNTAX  INTEGER { enable(1), disable(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Flag to enable/disable the LINK laser for Link 1."
                ::= { fc8gEntry 17 }

        fc8gLink2DataRate OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            dr8G(1),
                            dr4G(2),
                            dr2G(3),
                            dr1G(4)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Link 2 Data rate."
                ::= { fc8gEntry 18 }

        fc8gCpe2AutoDisable  OBJECT-TYPE
                SYNTAX  INTEGER { enable(1), disable(2) }
                ACCESS  read-write 
                STATUS  mandatory
                DESCRIPTION
                        "Flag to enable/disable automatic CPE disable for Link 2."
                ::= { fc8gEntry 19 }

        fc8gCpe2LaserEnabled OBJECT-TYPE
                SYNTAX  INTEGER { enable(1), disable(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Flag to enable/disable the CPE laser for Link 2."
                ::= { fc8gEntry 20 }

        fc8gLink2LaserEnabled OBJECT-TYPE
                SYNTAX  INTEGER { enable(1), disable(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Flag to enable/disable the LINK laser for Link 2."
                ::= { fc8gEntry 21 }


        fc8gAdminState   OBJECT-TYPE
                SYNTAX  INTEGER { disable(1), enable(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Administrative control for the module. Default 
                         value is enable. When disabled, no alarms/events are
                         generated for the module."
                ::= {  fc8gEntry 22 }

        fc8gSetState     OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            other(1), 
                            warmboot(2),
                            enableChannel1LinkLoopback(3),
                            enableChannel1CpeLoopback(4),
                            enableChannel2LinkLoopback(5),
                            enableChannel2CpeLoopback(6),
                            disableChannel1loopback(7),
                            disableChannel2loopback(8)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Instruct the module to do a warmboot or loopback. Successive loopbacks can be issued. 
                          A get on this will always return 'other'."
                ::= { fc8gEntry 23 }

        fc8gPortTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF Fc8gPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each set
                         of ports on the module.  Ports are divided into two
                         sets: mux ports and demux ports."
                ::= { fc8g 3 }

        fc8gPortEntry    OBJECT-TYPE
                SYNTAX  Fc8gPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { fc8gPortLocation, fc8gPortShelf, fc8gPortSlot, fc8gPortIndex }
                ::= { fc8gPortTable 1 }

        Fc8gPortEntry    ::=
                SEQUENCE 
                {
                        fc8gPortLocation               CardLocation,
                        fc8gPortShelf                  CardShelf,
                        fc8gPortSlot                   SlotInput,
                        fc8gPortIndex                  INTEGER,
                        fc8gPortName                   CardName,
                        fc8gPortMode                   INTEGER,
                        fc8gPortWavelength             DisplayString,
                        fc8gPortRxPower                DisplayString,
                        fc8gPortTxState                INTEGER,
                        fc8gPortTxReach                INTEGER,
                        fc8gPortSfpXfpSerialNumber     DisplayString
                }

        fc8gPortLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Location of the module."
                ::= { fc8gPortEntry 1 }

        fc8gPortShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The shelf where the module resides."
                ::= { fc8gPortEntry 2 }

        fc8gPortSlot     OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf where the module resides."
                ::= { fc8gPortEntry 3 }

        fc8gPortIndex    OBJECT-TYPE
                SYNTAX  INTEGER  { link1(1), cpe1(2), link2(3), cpe2(4) }
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Port for which the below values apply."
                ::= { fc8gPortEntry 4 }

        fc8gPortName     OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port name."
                ::= { fc8gPortEntry 5 }

        fc8gPortMode     OBJECT-TYPE
                SYNTAX  INTEGER { enabled(1), loopback(2) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port mode."
                ::= { fc8gPortEntry 6 }

        fc8gPortWavelength   OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port wavelength."
                ::= { fc8gPortEntry 7 }

        fc8gPortRxPower  OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Reported port receive power."
                ::= { fc8gPortEntry 8 }

        fc8gPortTxState  OBJECT-TYPE
                SYNTAX  INTEGER  { na(0), on(1), off(2) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "State of port transmitter."
                ::= { fc8gPortEntry 9 }

        fc8gPortTxReach  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port optical reach in meters."
                ::= { fc8gPortEntry 10 }

        fc8gPortSfpXfpSerialNumber  OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port SFP/XFP serial number."
                ::= { fc8gPortEntry 11 }

        -- The elements in the ocm2 subgroup of the configuration group

        ocm2Number       OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of rows in the ocm2 table.  This number
                         is automatically updated whenever a new row is added
                         to the table below."
                ::= { ocm2 1 }

        ocm2Table        OBJECT-TYPE
                SYNTAX  SEQUENCE OF Ocm2Entry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         OCM2 card"
                ::= { ocm2 2 }

        ocm2Entry        OBJECT-TYPE
                SYNTAX  Ocm2Entry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { ocm2CardLocation, ocm2CardShelf, ocm2CardSlot }
                ::= { ocm2Table 1 }

        Ocm2Entry        ::=
                SEQUENCE 
                {
                        ocm2CardLocation         CardLocation,
                        ocm2CardShelf            CardShelf,
                        ocm2CardSlot             INTEGER,
                        ocm2SerialNum            SerialString,
                        ocm2ModelNum             DisplayString,
                        ocm2HwName               DisplayString,
                        ocm2HwVersionID          VersionString,
                        ocm2MfgDate              DateAndTime,
                        ocm2FwName               CardName,
                        ocm2FwVersionID          VersionString,
                        ocm2FwDate               DateAndTime,
                        ocm2ModelType            INTEGER,
                        ocm2Name                 CardName,
                        ocm2Link1LineRate        INTEGER,
                        ocm2Link1AutoDisable     INTEGER,
                        ocm2Link1LinkName        LinkName,
                        ocm2Link1PathID          PathIdName,
                        ocm2Link2LineRate        INTEGER,
                        ocm2Link2AutoDisable     INTEGER,
                        ocm2Link2LinkName        LinkName,
                        ocm2Link2PathID          PathIdName,
                        ocm2AdminState           INTEGER,
                        ocm2SetState             INTEGER,
                        ocm2CleiNum              DisplayString,
                        ocm2NumPorts             INTEGER,
                        ocm2RegenMode            INTEGER,
                        ocm2FpgaRev              INTEGER
                }

        ocm2CardLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Location of the module."
                ::= { ocm2Entry 1 }

        ocm2CardShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf where the module resides."
                ::= { ocm2Entry 2 }

        ocm2CardSlot     OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf where the module resides.  
                         The range of valid values range from 1 through 17 
                         depending on the chassis type and the shelf where 
                         the module is in.  To delete this card, set this 
                         variable to 0."
                ::= { ocm2Entry 3 }

        ocm2SerialNum    OBJECT-TYPE
                SYNTAX  SerialString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module serial number."
                ::= { ocm2Entry 4 }

        ocm2ModelNum     OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module model number."
                ::= { ocm2Entry 5 }

        ocm2HwName       OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module hardware name." 
                ::= { ocm2Entry 6 }

        ocm2HwVersionID  OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module hardware version."
                ::= { ocm2Entry 7 }

        ocm2MfgDate      OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of manufacturing of the module"
                ::= { ocm2Entry 8 }

        ocm2FwName       OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module firmware name."
                ::= { ocm2Entry 9 }

        ocm2FwVersionID  OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Firmware version."
                ::= { ocm2Entry 10 }

        ocm2FwDate       OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Firmware release date and time."
                ::= { ocm2Entry 11 }

        ocm2ModelType    OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Model type of the module."
                ::= { ocm2Entry 12 }

        ocm2Name         OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "User configurable name of the module."
                ::= { ocm2Entry 13 }

        ocm2Link1LineRate OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            na(0),
                            oc3(1),
                            oc12(2),
                            oc48(3),
                            gbe(4),
                            fc(5),
                            escon(8),
                            fc2(10),
                            hlf_fc(14),
                            infiniband(15),
                            disabled(255)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Link 1 line rate."
                ::= { ocm2Entry 14 }

        ocm2Link1AutoDisable  OBJECT-TYPE
                SYNTAX  INTEGER { na(0), enable(1), disable(2) }
                ACCESS  read-write 
                STATUS  mandatory
                DESCRIPTION
                        "Flag to enable/disable automatic CPE disable for Link 1."
                ::= { ocm2Entry 15 }

        ocm2Link1LinkName     OBJECT-TYPE
                SYNTAX  LinkName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Link 1 link name for fiber between the local and the
                         remote card."
                ::= { ocm2Entry 16 }

        ocm2Link1PathID       OBJECT-TYPE
                SYNTAX  PathIdName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Link 1 path ID name associated with the module. Set input 
                         equal to NULL will remove the card off the path 
                         and also remove the path if no other modules are 
                         associated with that path."
                ::= { ocm2Entry 17 }

        ocm2Link2LineRate OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            na(0),
                            oc3(1),
                            oc12(2),
                            oc48(3),
                            gbe(4),
                            fc(5),
                            escon(8),
                            fc2(10),
                            hlf_fc(14),
                            infiniband(15),
                            disabled(255)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Link 2 line rate."
                ::= { ocm2Entry 18 }

        ocm2Link2AutoDisable  OBJECT-TYPE
                SYNTAX  INTEGER { na(0), enable(1), disable(2) }
                ACCESS  read-write 
                STATUS  mandatory
                DESCRIPTION
                        "Flag to enable/disable automatic CPE disable for Link 2."
                ::= { ocm2Entry 19 }

        ocm2Link2LinkName     OBJECT-TYPE
                SYNTAX  LinkName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Link 2 link name for fiber between the local and the
                         remote card."
                ::= { ocm2Entry 20 }

        ocm2Link2PathID       OBJECT-TYPE
                SYNTAX  PathIdName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Link 2 path ID name associated with the module. Set input 
                         equal to NULL will remove the card off the path 
                         and also remove the path if no other modules are 
                         associated with that path."
                ::= { ocm2Entry 21 }

        ocm2AdminState   OBJECT-TYPE
                SYNTAX  INTEGER { disable(1), enable(2), na(3) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Administrative control for the module. Default 
                         value is enable. When disabled, no alarms/events are
                         generated for the module."
                ::= {  ocm2Entry 22 }

        ocm2SetState     OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            other(1), 
                            warmboot(2),
                            enableLink1Loopback(3),
                            enableLink2Loopback(4),
                            disableLink1loopback(5),
                            disableLink2loopback(6)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Instruct the module to do a warmboot. A get on this will
                         always return 'other'."
                ::= { ocm2Entry 23 }

        ocm2CleiNum      OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CLEI number of the module."
                ::= { ocm2Entry 24 }

        ocm2NumPorts    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total port numbers on each OCM2 card."
                ::= { ocm2Entry 25 }

        ocm2RegenMode    OBJECT-TYPE
                SYNTAX  INTEGER { enabled(1), disabled(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Set or clear OCM2 regen mode."
                ::= { ocm2Entry 26 }

        ocm2FpgaRev    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "FPGA revision for the module."
                ::= { ocm2Entry 27 }

        ocm2PortTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF Ocm2PortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each set
                         of ports on the module.  Ports are divided into two
                         sets: mux ports and demux ports."
                ::= { ocm2 3 }

        ocm2PortEntry    OBJECT-TYPE
                SYNTAX  Ocm2PortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { ocm2PortLocation, ocm2PortShelf, ocm2PortSlot, ocm2PortIndex }
                ::= { ocm2PortTable 1 }

        Ocm2PortEntry    ::=
                SEQUENCE 
                {
                        ocm2PortLocation               CardLocation,
                        ocm2PortShelf                  CardShelf,
                        ocm2PortSlot                   SlotInput,
                        ocm2PortIndex                  INTEGER,
                        ocm2PortMode                   INTEGER,
                        ocm2PortItu                    INTEGER,
                        ocm2PortWavelength             DisplayString,
                        ocm2PortRxPower                DisplayString,
                        ocm2PortTxState                INTEGER,
                        ocm2PortTxReach                INTEGER,
                        ocm2PortSfpSerialNumber        DisplayString
                }

        ocm2PortLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Location of the module."
                ::= { ocm2PortEntry 1 }

        ocm2PortShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The shelf where the module resides."
                ::= { ocm2PortEntry 2 }

        ocm2PortSlot     OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf where the module resides."
                ::= { ocm2PortEntry 3 }

        ocm2PortIndex    OBJECT-TYPE
                SYNTAX  INTEGER  { link1(1), cpe1(2), link2(3), cpe2(4) }
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Port for which the below values apply."
                ::= { ocm2PortEntry 4 }

        ocm2PortMode     OBJECT-TYPE
                SYNTAX  INTEGER { na(0), disabled(1), enabled(2), loopback(3) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port mode."
                ::= { ocm2PortEntry 5 }

        ocm2PortItu      OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port ITU number.  The ITU number is determined
                         from the SFP wavelength."
                ::= { ocm2PortEntry 6 }

        ocm2PortWavelength   OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Wavelength from port SFP."
                ::= { ocm2PortEntry 7 }

        ocm2PortRxPower  OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Receive power reported by port SFP."
                ::= { ocm2PortEntry 8 }

        ocm2PortTxState  OBJECT-TYPE
                SYNTAX  INTEGER  { na(0), on(1), off(2) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "State of port SFP transmitter."
                ::= { ocm2PortEntry 9 }

        ocm2PortTxReach  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Optical reach in meters reported by port SFP."
                ::= { ocm2PortEntry 10 }

        ocm2PortSfpSerialNumber  OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port SFP serial number."
                ::= { ocm2PortEntry 11 }

        ocm2ConnTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF Ocm2ConnEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each set
                         of ports on the module.  Ports are divided into two
                         sets: mux ports and demux ports."
                ::= { ocm2 4 }

        ocm2ConnEntry    OBJECT-TYPE
                SYNTAX  Ocm2ConnEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { ocm2ConnCardLocation, ocm2ConnCardShelf, ocm2ConnCardSlot, ocm2ConnCardPortType }
                ::= { ocm2ConnTable 1 }

        Ocm2ConnEntry    ::=
                SEQUENCE 
                {
                        ocm2ConnCardLocation           CardLocation,
                        ocm2ConnCardShelf              CardShelf,
                        ocm2ConnCardSlot               SlotInput,
                        ocm2ConnCardPortType           INTEGER,
                        ocm2ConnCardType               CardType,
                        ocm2ConnLocation               CardLocation,
                        ocm2ConnShelf                  ShelfInput,
                        ocm2ConnSlot                   SlotInput,
                        ocm2ConnPort                   INTEGER
                }

        ocm2ConnCardLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Location of the module."
                ::= { ocm2ConnEntry 1 }

        ocm2ConnCardShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The shelf where the module resides."
                ::= { ocm2ConnEntry 2 }

        ocm2ConnCardSlot OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf where the module resides."
                ::= { ocm2ConnEntry 3 }

        ocm2ConnCardPortType OBJECT-TYPE
                SYNTAX  INTEGER  { link1tx(1), link1rx(2), link2tx(3), link2rx(4), cpe1tx(5), cpe1rx(6), cpe2tx(7), cpe2rx(8) }
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Port for which the below values apply."
                ::= { ocm2ConnEntry 4 }

        ocm2ConnCardType OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module type connected to port."
                ::= { ocm2ConnEntry 5 }

        ocm2ConnLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The chassis location of the card connected to
                         this port."
                ::= { ocm2ConnEntry 6 }

        ocm2ConnShelf    OBJECT-TYPE
                SYNTAX  ShelfInput
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf of the card connected to this port"
                ::= { ocm2ConnEntry 7 }

        ocm2ConnSlot     OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The slot of the card connected to this port"
                ::= { ocm2ConnEntry 8 }

        ocm2ConnPort     OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Conn port for the OCM2's port. Possible values based on 
                         card types that can be connected to are:
                         FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local  Tx
                               4=Local  Rx, 5=Conn B Tx, 6=Conn B Rx
                         OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1/MCMESC: 1=Link Tx, 2=Link Rx 
                         OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN
                         OSAM: 1=IN, 2=OUT
                         W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT
                         W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT
                         UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
                                    4=Link B Rx, 5=Local Tx, 6=Local Rx.
                         Entry supported by all Mux modules except MD100-40 & BD4."
                ::= { ocm2ConnEntry 9 }

        -- The elements in the osc subgroup of the configuration group

        oscNumber       OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of rows in the osc table.  This number
                         is automatically updated whenever a new row is added
                         to the table below."
                ::= { osc 1 }

        oscTable        OBJECT-TYPE
                SYNTAX  SEQUENCE OF OscEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         OSC card"
                ::= { osc 2 }

        oscEntry        OBJECT-TYPE
                SYNTAX  OscEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { oscCardLocation, oscCardShelf, oscCardSlot }
                ::= { oscTable 1 }

        OscEntry        ::=
                SEQUENCE 
                {
                        oscCardLocation         CardLocation,
                        oscCardShelf            CardShelf,
                        oscCardSlot             INTEGER,
                        oscSerialNum            SerialString,
                        oscModelNum             DisplayString,
                        oscHwName               DisplayString,
                        oscHwVersionID          VersionString,
                        oscMfgDate              DateAndTime,
                        oscFwName               CardName,
                        oscFwVersionID          VersionString,
                        oscFwDate               DateAndTime,
                        oscAdminState           INTEGER,
                        oscModelType            INTEGER,
                        oscName                 CardName,
                        oscPathID               PathIdName,
                        oscSetState             INTEGER,
                        oscCleiNum              DisplayString,
                        oscNumPorts             INTEGER,
                        oscFpgaRev              INTEGER
                }

        oscCardLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Location of the module."
                ::= { oscEntry 1 }

        oscCardShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf where the module resides."
                ::= { oscEntry 2 }

        oscCardSlot     OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf where the module resides.  
                         The range of valid values range from 1 through 17 
                         depending on the chassis type and the shelf where 
                         the module is in.  To delete this card, set this 
                         variable to 0."
                ::= { oscEntry 3 }

        oscSerialNum    OBJECT-TYPE
                SYNTAX  SerialString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module serial number."
                ::= { oscEntry 4 }

        oscModelNum     OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module model number."
                ::= { oscEntry 5 }

        oscHwName       OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module hardware name." 
                ::= { oscEntry 6 }

        oscHwVersionID  OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module hardware version."
                ::= { oscEntry 7 }

        oscMfgDate      OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of manufacturing of the module"
                ::= { oscEntry 8 }

        oscFwName       OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module firmware name."
                ::= { oscEntry 9 }

        oscFwVersionID  OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Firmware version."
                ::= { oscEntry 10 }

        oscFwDate       OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Firmware release date and time."
                ::= { oscEntry 11 }

        oscAdminState   OBJECT-TYPE
                SYNTAX  INTEGER { disable(1), enable(2), na(3) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Administrative control for the module. Default 
                         value is enable. When disabled, no alarms/events are
                         generated for the module."
                ::= {  oscEntry 12}

        oscModelType    OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Model type of the module."
                ::= { oscEntry 13 }

        oscName         OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "User configurable name of the module."
                ::= { oscEntry 14 }

        oscPathID       OBJECT-TYPE
                SYNTAX  PathIdName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Path ID name associated with the module. Set input 
                         equal to NULL will remove the card off the path 
                         and also remove the path if no other modules are 
                         associated with that path."
                ::= { oscEntry 15 }

        oscSetState     OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            other(1), 
                            warmboot(2)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Instruct the module to do a warmboot. A get on this will
                         always return 'other'."
                ::= { oscEntry 16 }

        oscCleiNum      OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CLEI number of the module."
                ::= { oscEntry 17 }

        oscNumPorts    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total port numbers on each OSC card."
                ::= { oscEntry 18 }

        oscFpgaRev    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "FPGA revision for the module."
                ::= { oscEntry 19 }

        oscPortTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF OscPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each set
                         of ports on the module.  Ports are divided into two
                         sets: mux ports and demux ports."
                ::= { osc 3 }

        oscPortEntry    OBJECT-TYPE
                SYNTAX  OscPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { oscPortLocation, oscPortShelf, oscPortSlot, oscPortIndex }
                ::= { oscPortTable 1 }

        OscPortEntry    ::=
                SEQUENCE 
                {
                        oscPortLocation               CardLocation,
                        oscPortShelf                  CardShelf,
                        oscPortSlot                   SlotInput,
                        oscPortIndex                  INTEGER,
                        oscPortItu                    INTEGER,
                        oscPortWavelength             DisplayString,
                        oscPortRxPower                DisplayString,
                        oscPortTxState                INTEGER,
                        oscPortTxReach                INTEGER,
                        oscPortSfpSerialNumber        DisplayString
                }

        oscPortLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Location of the module."
                ::= { oscPortEntry 1 }

        oscPortShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The shelf where the module resides."
                ::= { oscPortEntry 2 }

        oscPortSlot     OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf where the module resides."
                ::= { oscPortEntry 3 }

        oscPortIndex    OBJECT-TYPE
                SYNTAX  INTEGER  { link(1) }
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Port for which the below values apply."
                ::= { oscPortEntry 4 }

        oscPortItu      OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port ITU number.  The ITU number is determined
                         from the SFP wavelength."
                ::= { oscPortEntry 5 }

        oscPortWavelength   OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Wavelength from port SFP."
                ::= { oscPortEntry 6 }

        oscPortRxPower  OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Receive power reported by port SFP."
                ::= { oscPortEntry 7}

        oscPortTxState  OBJECT-TYPE
                SYNTAX  INTEGER  { na(0), on(1), off(2) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "State of port SFP transmitter."
                ::= { oscPortEntry 8 }

        oscPortTxReach  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Optical reach in meters reported by port SFP."
                ::= { oscPortEntry 9 }

        oscPortSfpSerialNumber  OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port SFP serial number."
                ::= { oscPortEntry 10 }

        -- The elements in the ocm4g subgroup of the configuration group

        ocm4gNumber       OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of rows in the ocm4g table.  This number
                         is automatically updated whenever a new row is added
                         to the table below."
                ::= { ocm4g 1 }

        ocm4gTable        OBJECT-TYPE
                SYNTAX  SEQUENCE OF Ocm4gEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         OCM4G card"
                ::= { ocm4g 2 }

        ocm4gEntry        OBJECT-TYPE
                SYNTAX  Ocm4gEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { ocm4gCardLocation, ocm4gCardShelf, ocm4gCardSlot }
                ::= { ocm4gTable 1 }

        Ocm4gEntry        ::=
                SEQUENCE 
                {
                        ocm4gCardLocation         INTEGER,
                        ocm4gCardShelf            CardShelf,
                        ocm4gCardSlot             INTEGER,
                        ocm4gSerialNum            SerialString,
                        ocm4gModelNum             DisplayString,
                        ocm4gHwName               DisplayString,
                        ocm4gHwVersionID          VersionString,
                        ocm4gMfgDate              DateAndTime,
                        ocm4gFwName               CardName,
                        ocm4gFwVersionID          VersionString,
                        ocm4gFwDate               DateAndTime,
                        ocm4gModelType            INTEGER,
                        ocm4gName                 CardName,
                        ocm4gLink1LineRate        INTEGER,
                        ocm4gLink1AutoDisable     INTEGER,
                        ocm4gLink1LinkName        LinkName,
                        ocm4gLink1PathID          PathIdName,
                        ocm4gLink2LineRate        INTEGER,
                        ocm4gLink2AutoDisable     INTEGER,
                        ocm4gLink2LinkName        LinkName,
                        ocm4gLink2PathID          PathIdName,
                        ocm4gAdminState           INTEGER,
                        ocm4gSetState             INTEGER,
                        ocm4gCleiNum              DisplayString,
                        ocm4gNumPorts             INTEGER,
                        ocm4gFpgaRev              INTEGER
                }

        ocm4gCardLocation OBJECT-TYPE
                SYNTAX  INTEGER { local(1) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Location of the module."
                ::= { ocm4gEntry 1 }

        ocm4gCardShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf where the module resides."
                ::= { ocm4gEntry 2 }

        ocm4gCardSlot     OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf where the module resides.  
                         The range of valid values range from 1 through 17 
                         depending on the chassis type and the shelf where 
                         the module is in.  To delete this card, set this 
                         variable to 0."
                ::= { ocm4gEntry 3 }

        ocm4gSerialNum    OBJECT-TYPE
                SYNTAX  SerialString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module serial number."
                ::= { ocm4gEntry 4 }

        ocm4gModelNum     OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module model number."
                ::= { ocm4gEntry 5 }

        ocm4gHwName       OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module hardware name." 
                ::= { ocm4gEntry 6 }

        ocm4gHwVersionID  OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module hardware version."
                ::= { ocm4gEntry 7 }

        ocm4gMfgDate      OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of manufacturing of the module"
                ::= { ocm4gEntry 8 }

        ocm4gFwName       OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module firmware name."
                ::= { ocm4gEntry 9 }

        ocm4gFwVersionID  OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Firmware version."
                ::= { ocm4gEntry 10 }

        ocm4gFwDate       OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Firmware release date and time."
                ::= { ocm4gEntry 11 }

        ocm4gModelType    OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Model type of the module."
                ::= { ocm4gEntry 12 }

        ocm4gName         OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "User configurable name of the module."
                ::= { ocm4gEntry 13 }

        ocm4gLink1LineRate OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            na(0),
                            oc3(1),
                            oc12(2),
                            oc48(3),
                            gbe(4),
                            fc(5),
                            escon(8),
                            fc2(10),
                            hlf_fc(14),
                            infiniband(15),
                            fourG(16),
                            twoR(17),
                            disabled(255)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Link 1 line rate."
                ::= { ocm4gEntry 14 }

        ocm4gLink1AutoDisable  OBJECT-TYPE
                SYNTAX  INTEGER { na(0), enable(1), disable(2) }
                ACCESS  read-write 
                STATUS  mandatory
                DESCRIPTION
                        "Flag to enable/disable automatic CPE disable for Link 1."
                ::= { ocm4gEntry 15 }

        ocm4gLink1LinkName     OBJECT-TYPE
                SYNTAX  LinkName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Link 1 link name for fiber between the local and the
                         remote card."
                ::= { ocm4gEntry 16 }

        ocm4gLink1PathID       OBJECT-TYPE
                SYNTAX  PathIdName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Link 1 path ID name associated with the module. Set input 
                         equal to NULL will remove the card off the path 
                         and also remove the path if no other modules are 
                         associated with that path."
                ::= { ocm4gEntry 17 }

        ocm4gLink2LineRate OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            na(0),
                            oc3(1),
                            oc12(2),
                            oc48(3),
                            gbe(4),
                            fc(5),
                            escon(8),
                            fc2(10),
                            hlf_fc(14),
                            infiniband(15),
                            fourG(16),
                            twoR(17),
                            disabled(255)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Link 2 line rate."
                ::= { ocm4gEntry 18 }

        ocm4gLink2AutoDisable  OBJECT-TYPE
                SYNTAX  INTEGER { na(0), enable(1), disable(2) }
                ACCESS  read-write 
                STATUS  mandatory
                DESCRIPTION
                        "Flag to enable/disable automatic CPE disable for Link 2."
                ::= { ocm4gEntry 19 }

        ocm4gLink2LinkName     OBJECT-TYPE
                SYNTAX  LinkName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Link 2 link name for fiber between the local and the
                         remote card."
                ::= { ocm4gEntry 20 }

        ocm4gLink2PathID       OBJECT-TYPE
                SYNTAX  PathIdName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Link 2 path ID name associated with the module. Set input 
                         equal to NULL will remove the card off the path 
                         and also remove the path if no other modules are 
                         associated with that path."
                ::= { ocm4gEntry 21 }

        ocm4gAdminState   OBJECT-TYPE
                SYNTAX  INTEGER { disable(1), enable(2), na(3) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Administrative control for the module. Default 
                         value is enable. When disabled, no alarms/events are
                         generated for the module."
                ::= {  ocm4gEntry 22 }

        ocm4gSetState     OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            other(1), 
                            warmboot(2),
                            enableLink1Loopback(3),
                            enableLink2Loopback(4),
                            disableLink1loopback(5),
                            disableLink2loopback(6)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Instruct the module to do a warmboot. A get on this will
                         always return 'other'."
                ::= { ocm4gEntry 23 }

        ocm4gCleiNum      OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CLEI number of the module."
                ::= { ocm4gEntry 24 }

        ocm4gNumPorts    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total port numbers on each OCM4G card."
                ::= { ocm4gEntry 25 }

        ocm4gFpgaRev    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "FPGA revision for the module."
                ::= { ocm4gEntry 26 }

        ocm4gPortTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF Ocm4gPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each set
                         of ports on the module.  Ports are divided into two
                         sets: mux ports and demux ports."
                ::= { ocm4g 3 }

        ocm4gPortEntry    OBJECT-TYPE
                SYNTAX  Ocm4gPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { ocm4gPortLocation, ocm4gPortShelf, ocm4gPortSlot, ocm4gPortIndex }
                ::= { ocm4gPortTable 1 }

        Ocm4gPortEntry    ::=
                SEQUENCE 
                {
                        ocm4gPortLocation               INTEGER,
                        ocm4gPortShelf                  CardShelf,
                        ocm4gPortSlot                   SlotInput,
                        ocm4gPortIndex                  INTEGER,
                        ocm4gPortMode                   INTEGER,
                        ocm4gPortItu                    INTEGER,
                        ocm4gPortWavelength             DisplayString,
                        ocm4gPortRxPower                DisplayString,
                        ocm4gPortTxState                INTEGER,
                        ocm4gPortTxReach                INTEGER,
                        ocm4gPortSfpSerialNumber        DisplayString
                }

        ocm4gPortLocation OBJECT-TYPE
                SYNTAX  INTEGER { local(1) }
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Location of the module."
                ::= { ocm4gPortEntry 1 }

        ocm4gPortShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The shelf where the module resides."
                ::= { ocm4gPortEntry 2 }

        ocm4gPortSlot     OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf where the module resides."
                ::= { ocm4gPortEntry 3 }

        ocm4gPortIndex    OBJECT-TYPE
                SYNTAX  INTEGER  { link1(1), cpe1(2), link2(3), cpe2(4) }
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Port for which the below values apply."
                ::= { ocm4gPortEntry 4 }

        ocm4gPortMode     OBJECT-TYPE
                SYNTAX  INTEGER { na(0), disabled(1), enabled(2), loopback(3) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port mode."
                ::= { ocm4gPortEntry 5 }

        ocm4gPortItu      OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port ITU number.  The ITU number is determined
                         from the SFP wavelength."
                ::= { ocm4gPortEntry 6 }

        ocm4gPortWavelength   OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Wavelength from port SFP."
                ::= { ocm4gPortEntry 7 }

        ocm4gPortRxPower  OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Receive power reported by port SFP."
                ::= { ocm4gPortEntry 8 }

        ocm4gPortTxState  OBJECT-TYPE
                SYNTAX  INTEGER  { na(0), on(1), off(2) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "State of port SFP transmitter."
                ::= { ocm4gPortEntry 9 }

        ocm4gPortTxReach  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Optical reach in meters reported by port SFP."
                ::= { ocm4gPortEntry 10 }

        ocm4gPortSfpSerialNumber  OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port SFP serial number."
                ::= { ocm4gPortEntry 11 }

        ocm4gConnTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF Ocm4gConnEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each set
                         of ports on the module.  Ports are divided into two
                         sets: mux ports and demux ports."
                ::= { ocm4g 4 }

        ocm4gConnEntry    OBJECT-TYPE
                SYNTAX  Ocm4gConnEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { ocm4gConnCardLocation, ocm4gConnCardShelf, ocm4gConnCardSlot, ocm4gConnCardPortType }
                ::= { ocm4gConnTable 1 }

        Ocm4gConnEntry    ::=
                SEQUENCE 
                {
                        ocm4gConnCardLocation           INTEGER,
                        ocm4gConnCardShelf              CardShelf,
                        ocm4gConnCardSlot               SlotInput,
                        ocm4gConnCardPortType           INTEGER,
                        ocm4gConnCardType               CardType,
                        ocm4gConnLocation               INTEGER,
                        ocm4gConnShelf                  ShelfInput,
                        ocm4gConnSlot                   SlotInput,
                        ocm4gConnPort                   INTEGER
                }

        ocm4gConnCardLocation OBJECT-TYPE
                SYNTAX  INTEGER { local(1) }
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Location of the module."
                ::= { ocm4gConnEntry 1 }

        ocm4gConnCardShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The shelf where the module resides."
                ::= { ocm4gConnEntry 2 }

        ocm4gConnCardSlot OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf where the module resides."
                ::= { ocm4gConnEntry 3 }

        ocm4gConnCardPortType OBJECT-TYPE
                SYNTAX  INTEGER  { link1tx(1), link1rx(2), link2tx(3), link2rx(4), cpe1tx(5), cpe1rx(6), cpe2tx(7), cpe2rx(8) }
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Port for which the below values apply."
                ::= { ocm4gConnEntry 4 }

        ocm4gConnCardType OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module type connected to port."
                ::= { ocm4gConnEntry 5 }

        ocm4gConnLocation OBJECT-TYPE
                SYNTAX  INTEGER { local(1) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The chassis location of the card connected to
                         this port."
                ::= { ocm4gConnEntry 6 }

        ocm4gConnShelf    OBJECT-TYPE
                SYNTAX  ShelfInput
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf of the card connected to this port"
                ::= { ocm4gConnEntry 7 }

        ocm4gConnSlot     OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The slot of the card connected to this port"
                ::= { ocm4gConnEntry 8 }

        ocm4gConnPort     OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Conn port for the OCM4G's port. Possible values based on 
                         card types that can be connected to are:
                         FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local  Tx
                               4=Local  Rx, 5=Conn B Tx, 6=Conn B Rx
                         OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1/MCMESC: 1=Link Tx, 2=Link Rx 
                         OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN
                         OSAM: 1=IN, 2=OUT
                         W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT
                         W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT
                         UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
                                    4=Link B Rx, 5=Local Tx, 6=Local Rx.
                         Entry supported by all Mux modules except MD100-40 & BD4."
                ::= { ocm4gConnEntry 9 }

        -- The elements in the oet subgroup of the configuration group

        oetNumber       OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of rows in the oet table.  This number
                         is automatically updated whenever a new row is added
                         to the table below."
                ::= { oet 1 }

        oetTable        OBJECT-TYPE
                SYNTAX  SEQUENCE OF OetEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         OET card"
                ::= { oet 2 }

        oetEntry        OBJECT-TYPE
                SYNTAX  OetEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { oetCardLocation, oetCardShelf, oetCardSlot }
                ::= { oetTable 1 }

        OetEntry        ::=
                SEQUENCE 
                {
                        oetCardLocation         CardLocation,
                        oetCardShelf            CardShelf,
                        oetCardSlot             INTEGER,
                        oetSerialNum            SerialString,
                        oetModelNum             DisplayString,
                        oetHwName               DisplayString,
                        oetHwVersionID          VersionString,
                        oetMfgDate              DateAndTime,
                        oetFwName               CardName,
                        oetFwVersionID          VersionString,
                        oetFwDate               DateAndTime,
                        oetModelType            INTEGER,
                        oetName                 CardName,
                        oetCleiNum              DisplayString,
                        oetFpgaRevMB            INTEGER,
                        oetFpgaRevDB            INTEGER,
                        oetCpldRev              INTEGER,
                        oetOpMode               INTEGER,
                        oetProtMode             INTEGER,
                        oetEAPSMode             INTEGER,
                        oetAdminState           INTEGER,
                        oetSetState             INTEGER,
                        oetConfigInProgress     INTEGER,
                        oetApplyChanges         INTEGER
                }

        oetCardLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Location of the module."
                ::= { oetEntry 1 }

        oetCardShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf where the module resides."
                ::= { oetEntry 2 }

        oetCardSlot     OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf where the module resides.  
                         The range of valid values range from 1 through 17 
                         depending on the chassis type and the shelf where 
                         the module is in.  To delete this card, set this 
                         variable to 0."
                ::= { oetEntry 3 }

        oetSerialNum    OBJECT-TYPE
                SYNTAX  SerialString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module serial number."
                ::= { oetEntry 4 }

        oetModelNum     OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module model number."
                ::= { oetEntry 5 }

        oetHwName       OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module hardware name." 
                ::= { oetEntry 6 }

        oetHwVersionID  OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module hardware version."
                ::= { oetEntry 7 }

        oetMfgDate      OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of manufacturing of the module"
                ::= { oetEntry 8 }

        oetFwName       OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module firmware name."
                ::= { oetEntry 9 }

        oetFwVersionID  OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Firmware version."
                ::= { oetEntry 10 }

        oetFwDate       OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Firmware release date and time."
                ::= { oetEntry 11 }

        oetModelType    OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Model type of the module."
                ::= { oetEntry 12 }

        oetName         OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "User configurable name of the module."
                ::= { oetEntry 13 }

        oetCleiNum      OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CLEI number of the module."
                ::= { oetEntry 14 }

        oetFpgaRevMB    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "FPGA revision for the module's mother board."
                ::= { oetEntry 15 }

        oetFpgaRevDB    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "FPGA revision for the module's daughter board."
                ::= { oetEntry 16 }

        oetCpldRev    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CPLD revision for the module."
                ::= { oetEntry 17 }

        oetOpMode OBJECT-TYPE
                SYNTAX  INTEGER  { mux(1), switch(2) }
                ACCESS  read-write 
                STATUS  mandatory
                DESCRIPTION
                        "Operating Mode (1=Mux Mode, 2=Switch Mode)."
                ::= { oetEntry 18 }

        oetProtMode OBJECT-TYPE
                SYNTAX  INTEGER  { on(1), off(2) }
                ACCESS  read-write 
                STATUS  mandatory
                DESCRIPTION
                        "Mux Protection."
                ::= { oetEntry 19 }

        oetEAPSMode OBJECT-TYPE
                SYNTAX  INTEGER  { disabled(1), linearEndpoint(2), linearNode(3),
                                   ringMaster(4), ringNode(5)  }
                ACCESS  read-write 
                STATUS  mandatory
                DESCRIPTION
                        "Ethernet Automatic Protection Switching."
                ::= { oetEntry 20 }

        oetAdminState   OBJECT-TYPE
                SYNTAX  INTEGER { disable(1), enable(2), na(3) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Administrative control for the module. Default 
                         value is enable. When disabled, no alarms/events are
                         generated for the module."
                ::= {  oetEntry 21 }

        oetSetState     OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            other(1), 
                            warmboot(2)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Instruct the module to do a warmboot. A get on this will
                         always return 'other'."
                ::= { oetEntry 22 }

        oetConfigInProgress OBJECT-TYPE
                SYNTAX  INTEGER  { yes(1), on(2) }
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Configured changes are pending, Apply Changes required
                         to finish."
                ::= { oetEntry 23 }

        oetApplyChanges OBJECT-TYPE
                SYNTAX  INTEGER { clear(1), apply(2), na(3) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Update device with pending configuration changes.
                         Read returns 'na'."
                ::= { oetEntry 24 }

        oetLinkTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF OetLinkEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each of
                         the Link ports on the module." 
                ::= { oet 3 }

        oetLinkEntry    OBJECT-TYPE
                SYNTAX  OetLinkEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { oetLinkLocation, oetLinkShelf, oetLinkSlot, oetLinkIndex }
                ::= { oetLinkTable 1 }

        OetLinkEntry    ::=
                SEQUENCE 
                {
                        oetLinkLocation               CardLocation,
                        oetLinkShelf                  CardShelf,
                        oetLinkSlot                   SlotInput,
                        oetLinkIndex                  INTEGER,
                        oetLinkEnable                 INTEGER,
                        oetLinkProtocol               INTEGER,
                        oetLinkName                   CardName,
                        oetLinkVlanIds                DisplayString,
                        oetLinkConfigInProgress       INTEGER,
                        oetLinkApplyChanges           INTEGER,
                        oetLinkMode                   INTEGER,
                        oetLinkItu                    INTEGER,
                        oetLinkWavelength             DisplayString,
                        oetLinkRxPower                DisplayString,
                        oetLinkTxState                INTEGER,
                        oetLinkTxReach                INTEGER,
                        oetLinkXfpSerialNumber        DisplayString
                }

        oetLinkLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Location of the module."
                ::= { oetLinkEntry 1 }

        oetLinkShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The shelf where the module resides."
                ::= { oetLinkEntry 2 }

        oetLinkSlot     OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf where the module resides."
                ::= { oetLinkEntry 3 }

        oetLinkIndex    OBJECT-TYPE
                SYNTAX  INTEGER { linkA(11), linkB(12) }
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Link for which the below values apply."
                ::= { oetLinkEntry 4 }

        oetLinkEnable   OBJECT-TYPE
                SYNTAX  INTEGER { enable(1), disable(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Enables or disables the link."
                ::= { oetLinkEntry 5 }

        oetLinkProtocol   OBJECT-TYPE
                SYNTAX  INTEGER { otu(1), lan(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Protocol."
                ::= { oetLinkEntry 6 }

        oetLinkName     OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Link name for fiber between the local and the
                         remote card."
                ::= { oetLinkEntry 7 }

        oetLinkVlanIds     OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..80))
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Comma List of VLAN Ids - single and ranges." 
                ::= { oetLinkEntry 8 }

        oetLinkConfigInProgress OBJECT-TYPE
                SYNTAX  INTEGER  { yes(1), on(2) }
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Configured changes are pending, Apply Changes required
                         to finish."
                ::= { oetLinkEntry 9 }

        oetLinkApplyChanges OBJECT-TYPE
                SYNTAX  INTEGER { clear(1), apply(2), na(3) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Update device with pending configuration changes.
                         Read returns 'na'."
                ::= { oetLinkEntry 10 }

        oetLinkMode     OBJECT-TYPE
                SYNTAX  INTEGER { na(0), disabled(1), enabled(2), loopback(3) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Link mode."
                ::= { oetLinkEntry 11 }

        oetLinkItu      OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Link ITU number.  The ITU number is determined
                         from the XFP wavelength."
                ::= { oetLinkEntry 12 }

        oetLinkWavelength   OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Wavelength from Link XFP."
                ::= { oetLinkEntry 13 }

        oetLinkRxPower  OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Receive power reported by Link XFP."
                ::= { oetLinkEntry 14 }

        oetLinkTxState  OBJECT-TYPE
                SYNTAX  INTEGER  { na(0), on(1), off(2) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "State of Link XFP transmitter."
                ::= { oetLinkEntry 15 }

        oetLinkTxReach  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Optical reach in meters reported by Link XFP."
                ::= { oetLinkEntry 16 }

        oetLinkXfpSerialNumber  OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Link XFP serial number."
                ::= { oetLinkEntry 17 }

        oetPortTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF OetPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each of
                         the CPE ports on the module." 
                ::= { oet 4 }

        oetPortEntry    OBJECT-TYPE
                SYNTAX  OetPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { oetPortLocation, oetPortShelf, oetPortSlot, oetPortIndex }
                ::= { oetPortTable 1 }

        OetPortEntry    ::=
                SEQUENCE 
                {
                        oetPortLocation               CardLocation,
                        oetPortShelf                  CardShelf,
                        oetPortSlot                   SlotInput,
                        oetPortIndex                  INTEGER,
                        oetPortEnable                 INTEGER,
                        oetPortALSD                   INTEGER,
                        oetPortFlowControl            INTEGER,
                        oetPortVlanId                 INTEGER,
                        oetPortName                   CardName,
                        oetPortConfigInProgress       INTEGER,
                        oetPortApplyChanges           INTEGER,
                        oetPortMode                   INTEGER,
                        oetPortItu                    INTEGER,
                        oetPortWavelength             DisplayString,
                        oetPortRxPower                DisplayString,
                        oetPortTxState                INTEGER,
                        oetPortTxReach                INTEGER,
                        oetPortSfpSerialNumber        DisplayString
                }

        oetPortLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Location of the module."
                ::= { oetPortEntry 1 }

        oetPortShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The shelf where the module resides."
                ::= { oetPortEntry 2 }

        oetPortSlot     OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf where the module resides."
                ::= { oetPortEntry 3 }

        oetPortIndex    OBJECT-TYPE
                SYNTAX  INTEGER { cpe(1), cpe(2), cpe(3), cpe(4), cpe(5), 
                     cpe(6), cpe(7), cpe(8), cpe(9), cpe(10)}
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Port for which the below values apply."
                ::= { oetPortEntry 4 }

        oetPortEnable   OBJECT-TYPE
                SYNTAX  INTEGER { enable(1), disable(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Enables or disables the port."
                ::= { oetPortEntry 5 }

        oetPortALSD     OBJECT-TYPE
                SYNTAX  INTEGER { disabled(1), local(2), remote(3) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Auto Laser Shutoff"
                ::= { oetPortEntry 6 }

        oetPortFlowControl   OBJECT-TYPE
                SYNTAX  INTEGER { enable(1), disable(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Enable or disable the port's flow control."
                ::= { oetPortEntry 7 }

        oetPortVlanId        OBJECT-TYPE
                SYNTAX  INTEGER(1..200)
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Network ID must be between 1 to 200."
                ::= { oetPortEntry 8 }

        oetPortName     OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Port name."
                ::= { oetPortEntry 9 }

        oetPortConfigInProgress OBJECT-TYPE
                SYNTAX  INTEGER  { yes(1), on(2) }
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Configured changes are pending, Apply Changes required
                         to finish."
                ::= { oetPortEntry 10 }

        oetPortApplyChanges OBJECT-TYPE
                SYNTAX  INTEGER { clear(1), apply(2), na(3) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Update device with pending configuration changes.
                         Read returns 'na'."
                ::= { oetPortEntry 11 }

        oetPortMode     OBJECT-TYPE
                SYNTAX  INTEGER { na(0), disabled(1), enabled(2), loopback(3) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port mode."
                ::= { oetPortEntry 12 }

        oetPortItu      OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port ITU number.  The ITU number is determined
                         from the SFP wavelength."
                ::= { oetPortEntry 13 }

        oetPortWavelength   OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Wavelength from Port SFP."
                ::= { oetPortEntry 14 }

        oetPortRxPower  OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Receive power reported by Port SFP."
                ::= { oetPortEntry 15 }

        oetPortTxState  OBJECT-TYPE
                SYNTAX  INTEGER  { na(0), on(1), off(2) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "State of Port SFP transmitter."
                ::= { oetPortEntry 16 }

        oetPortTxReach  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Optical reach in meters reported by Port SFP."
                ::= { oetPortEntry 17 }

        oetPortSfpSerialNumber  OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port SFP serial number."
                ::= { oetPortEntry 18 }

        -- The elements in the uob subgroup of the configuration group

        uobNumber      OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of rows in the uob table.  This number
                         is automatically updated whenever a new row is added
                         to the table below."
                ::= { uob 1 }

        uobTable        OBJECT-TYPE
                SYNTAX  SEQUENCE OF UobEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         UOB card"
                ::= { uob 2 }

        uobEntry        OBJECT-TYPE
                SYNTAX  UobEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { uobCardLocation, uobCardShelf, uobCardSlot }
                ::= { uobTable 1 }

        UobEntry        ::=
                SEQUENCE 
                {
                        uobCardLocation         CardLocation,
                        uobCardShelf            CardShelf,
                        uobCardSlot             INTEGER,
                        uobSerialNum            SerialString,
                        uobModelNum             DisplayString,
                        uobHwName               DisplayString,
                        uobHwVersionID          VersionString,
                        uobMfgDate              DateAndTime,
                        uobFwName               CardName,
                        uobFwVersionID          VersionString,
                        uobFwDate               DateAndTime,
                        uobModelType            INTEGER,
                        uobCfgName              CardName,
                        uobModuleName           DisplayString,
                        uobAdminState           INTEGER,
                        uobSetState             INTEGER,
                        uobCleiNum              DisplayString,
                        uobFpgaRev              INTEGER,
                        uobOperationMode        INTEGER,
                        uobOutPower             DisplayString,
                        uobGain                 DisplayString,
                        uobGainTilt             DisplayString,
                        uobLosMode              INTEGER,
                        uobLosThreshold         DisplayString,
                        uobRflThreshold         DisplayString
                }

        uobCardLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Location of the module."
                ::= { uobEntry 1 }

        uobCardShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf where the module resides."
                ::= { uobEntry 2 }

        uobCardSlot     OBJECT-TYPE
                SYNTAX  SlotInput
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf where the module resides.  
                         The range of valid values range from 1 through 17 
                         depending on the chassis type and the shelf where 
                         the module is in.  To delete this card, set this 
                         variable to 0."
                ::= { uobEntry 3 }

        uobSerialNum    OBJECT-TYPE
                SYNTAX  SerialString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module serial number."
                ::= { uobEntry 4 }

        uobModelNum     OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module model number."
                ::= { uobEntry 5 }

        uobHwName       OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module hardware name." 
                ::= { uobEntry 6 }

        uobHwVersionID  OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module hardware version."
                ::= { uobEntry 7 }

        uobMfgDate      OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Date and Time of manufacturing of the module"
                ::= { uobEntry 8 }

        uobFwName       OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module firmware name."
                ::= { uobEntry 9 }

        uobFwVersionID  OBJECT-TYPE
                SYNTAX  VersionString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Firmware version."
                ::= { uobEntry 10 }

        uobFwDate       OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Firmware release date and time."
                ::= { uobEntry 11 }

        uobModelType    OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Model type of the module."
                ::= { uobEntry 12 }

        uobCfgName      OBJECT-TYPE
                SYNTAX  CardName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "User configurable name of the module."
                ::= { uobEntry 13 }

        uobModuleName   OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "name of the module."
                ::= { uobEntry 14 }

        uobAdminState   OBJECT-TYPE
                SYNTAX  INTEGER { disable(1), enable(2), na(3) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Administrative control for the module. Default 
                         value is enable. When disabled, no alarms/events are
                         generated for the module."
                ::= {  uobEntry 15}

        uobSetState     OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            other(1), 
                            warmboot(2)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Instruct the module to do a warmboot. 
                         A get on this will always return 'other'."
                ::= { uobEntry 16 }

        uobCleiNum      OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CLEI number of the module."
                ::= { uobEntry 17 }

        uobFpgaRev    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "FPGA revision for the module."
                ::= { uobEntry 18 }

        uobOperationMode OBJECT-TYPE
                SYNTAX  INTEGER { 
                        invalid(0), 
                        constainPower(1), 
                        constantGain(2), 
                        disabled(3) 
                                }
                ACCESS   read-write
                STATUS   mandatory
                DESCRIPTION
                        "Invalid, Constain Power, Constant Gain, Disabled.
                         Constain Power(1) is not valid on Fixed modules."
                ::= { uobEntry 19 }

        uobOutPower      OBJECT-TYPE
                SYNTAX   DisplayString
                ACCESS   read-write
                STATUS   mandatory
                DESCRIPTION
                " uobModuleName - Configured Power in dBm 
                          T17VO - range: -13.0 to 17.5 
                          T17VR - range: -13.0 to 17.5 
                          T20FR - range: -7.0  to 20.10 
                          T15FR - range: -7.0  to 15.10 "
                ::= { uobEntry 20 }

        uobGain         OBJECT-TYPE
                SYNTAX   DisplayString
                ACCESS   read-write
                STATUS   mandatory
                DESCRIPTION
                " uobModuleName - Configured Gain in dB 
                          T17VO - range: 10.0 to 20.0 
                          T17VR - range: 10.0 to 20.0 
                          T20FR - range: 16.0 to 28.0 default:22
                          T15FR - range: 16.0 to 28.0 default:22"
                ::= { uobEntry 21 }

        uobGainTilt      OBJECT-TYPE
                SYNTAX   DisplayString
                ACCESS   read-write
                STATUS   mandatory
                DESCRIPTION
                " uobModuleName - Configured Gain Tilt in dB 
                          T17VO - range: -2.0 to 2.0 
                          T17VR - range: -2.0 to 2.0 "
                ::= { uobEntry 22 }

        uobLosMode       OBJECT-TYPE
                SYNTAX  INTEGER { 
                        noEffect(1), 
                        disabledInAll(2), 
                        disabledInPower(3) 
                                }
                ACCESS   read-write
                STATUS   mandatory
                DESCRIPTION
                        " No effect, Disabled in all modes, 
                          Disabled in Power Mode only"
                ::= { uobEntry 23 }

        uobLosThreshold   OBJECT-TYPE
                SYNTAX   DisplayString
                ACCESS   read-write
                STATUS   mandatory
                DESCRIPTION
                " uobModuleName - Configured Los Threshold in dBm 
                          T17VO - range: -100.0 to 45.0 default: -31
                          T17VR - range: -100.0 to 45.0 default: -31
                          T20FR - range: -40.0  to -5.0 default: -35
                          T15FR - range: -40.0  to -5.0 default: -35"
                ::= { uobEntry 24 }

        uobRflThreshold   OBJECT-TYPE
                SYNTAX   DisplayString
                ACCESS   read-write
                STATUS   mandatory
                DESCRIPTION
                " uobModuleName - Configured Rfl Threshold in dB
                          T17VO - range:   0.0 to 50.0
                          T17VR - range: -23.0 to -14.0
                          T20FR - range: -23.0 to -14.0
                          T15FR - range: -23.0 to -14.0 "

                ::= { uobEntry 25 }

        -- The elements in the uobPerf subgroup of the current subgroup

        uobNumEvents    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         UOB modules in this time slot (15 minutes)."
                ::= { uobPerf 1 }
    

        uobPerfTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF UobPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each UOB module."
                ::= { uobPerf 2 }

        uobPerfEntry    OBJECT-TYPE
                SYNTAX  UobPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { uobPerfLocation, uobPerfShelf, uobPerfSlot }
                ::= { uobPerfTable 1 }

        UobPerfEntry    ::=
                SEQUENCE
                {
                        uobPerfLocation         CardLocation,
                        uobPerfShelf            CardShelf,
                        uobPerfSlot             INTEGER,
                        uobPerfState            CardState,
                        uobPerfStatus           CardStatus,
                        uobLastBootTime         DateAndTime,
                        uobAvailTime            Counter,
                        uobErrFreeSecs          Counter
                }

        uobPerfLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the module.  Choices are local or remote."
                ::= { uobPerfEntry 1 }

        uobPerfShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the module is in."
                ::= { uobPerfEntry 2 }

        uobPerfSlot     OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the module is in."
                ::= { uobPerfEntry 3 }

        uobPerfState    OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The state of the UOB module.  The states are:
                         online = 2 and offline = 3"
                ::= { uobPerfEntry 4 }

        uobPerfStatus   OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "This status represents the status of the UOB module 
                         and in general is different from the status of 
                         the system."
                ::= { uobPerfEntry 5 }

        uobLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this module."
                ::= { uobPerfEntry 6 }

        uobAvailTime    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this module has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { uobPerfEntry 7 }

        uobErrFreeSecs  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this module has not experienced any alarms."
                ::= { uobPerfEntry 8 }





        uobPmTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF UobPmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entry for the software counters."
                ::= { uobPerf 3 }

        uobPmEntry      OBJECT-TYPE
                SYNTAX  UobPmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { uobPmLocation, uobPmShelf, uobPmSlot }
                ::= { uobPmTable 1 }

        UobPmEntry     ::=
                SEQUENCE
                {
                        uobPmLocation               CardLocation,
                        uobPmShelf                  CardShelf,
                        uobPmSlot                   INTEGER,
                        uobPmSystemStatus           DisplayString,
                        uobPmPumpCurrent            DisplayString,
                        uobPmPumpTemp               DisplayString,
                        uobPmInputPower             DisplayString,
                        uobPmOutPower               DisplayString,
                        uobPmTotalGain              DisplayString,
                        uobPmReflection             DisplayString
                }

        uobPmLocation   OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the UOB card.  The values are: Local
                         or Remote.  The system automatically determines the
                         right value for this entry based on the known
                         UOB cards."
                ::= { uobPmEntry 1 }

        uobPmShelf      OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2.
                         The system automatically determines the right value
                         for this entry based on the known (available) UOB
                         cards."
                ::= { uobPmEntry 2 }

        uobPmSlot       OBJECT-TYPE 
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  Valid
                         values are: 1 to 17.  The system automatically
                         determines the right value for this entry based
                         on the known (available) UOB cards."
                ::= { uobPmEntry 3 }

        uobPmSystemStatus OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "System Status"
                ::= { uobPmEntry 4 }

        uobPmPumpCurrent OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Pump Current in mA"
                ::= { uobPmEntry 5 }

        uobPmPumpTemp OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Pump temp in C"
                ::= { uobPmEntry 6 }

        uobPmInputPower OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Input pwr in dBm"
                ::= { uobPmEntry 7 }

        uobPmOutPower OBJECT-TYPE
                SYNTAX   DisplayString
                ACCESS   read-only
                STATUS   mandatory
                DESCRIPTION
                        "Output pwr in dBm"
                ::= { uobPmEntry 8 }

        uobPmTotalGain  OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total gain in dB"
                ::= { uobPmEntry 9 }

        uobPmReflection OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Reflection in dB"
                ::= { uobPmEntry 10 }



        -- The elements in the uobHist subgroup of the historical subgroup

        uobHistTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF UobHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for historical
                         data collected for the UOB module."
                ::= { uobHist 1 }

        uobHistEntry    OBJECT-TYPE
                SYNTAX  UobHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { uobHMode }
                ::= { uobHistTable 1 }

        UobHistEntry    ::=
                SEQUENCE
                {
                        uobHMode                HistoryMode,
                        uobHNumEvents           Counter
                }

        uobHMode        OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { uobHistEntry 1 }

        uobHNumEvents   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         UOB modules."
                ::= { uobHistEntry 2 }

        uobHHistTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF UobHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each UOB module"
                ::= { uobHist 2 }

        uobHHistEntry   OBJECT-TYPE
                SYNTAX  UobHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { uobHHistMode, uobHHistLocation, uobHHistShelf,
                          uobHHistSlot }
                ::= { uobHHistTable 1 }

        UobHHistEntry   ::=
                SEQUENCE
                {
                        uobHHistMode            HistoryMode,
                        uobHHistLocation        CardLocation,
                        uobHHistShelf           CardShelf,
                        uobHHistSlot            INTEGER,
                        uobHLastBootTime        DateAndTime,
                        uobHAvailTime           Counter,
                        uobHErrFreeSecs         Counter
                }

        uobHHistMode    OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { uobHHistEntry 1 }

        uobHHistLocation    OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the module.  Choices are local or remote."
                ::= { uobHHistEntry 2 }

        uobHHistShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the module is in."
                ::= { uobHHistEntry 3 }

        uobHHistSlot    OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the module is in."
                ::= { uobHHistEntry 4 }

        uobHLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this module."
                ::= { uobHHistEntry 5 }

        uobHAvailTime   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this module has been up and
                         running."
                ::= { uobHHistEntry 6 }

        uobHErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this module has not
                         experienced any alarms."
                ::= { uobHHistEntry 7 }

        -- The elements in the fc8gPerf subgroup of the current subgroup

        fc8gNumEvents    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         FC8G modules in this time slot (15 minutes)."
                ::= { fc8gPerf 1 }
    

        fc8gPerfTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF Fc8gPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each FC8G module."
                ::= { fc8gPerf 2 }

        fc8gPerfEntry    OBJECT-TYPE
                SYNTAX  Fc8gPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { fc8gPerfLocation, fc8gPerfShelf, fc8gPerfSlot }
                ::= { fc8gPerfTable 1 }

        Fc8gPerfEntry    ::=
                SEQUENCE
                {
                        fc8gPerfLocation         CardLocation,
                        fc8gPerfShelf            CardShelf,
                        fc8gPerfSlot             INTEGER,
                        fc8gPerfState            CardState,
                        fc8gPerfStatus           CardStatus,
                        fc8gLastBootTime         DateAndTime,
                        fc8gAvailTime            Counter,
                        fc8gErrFreeSecs          Counter
                }

        fc8gPerfLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the module.  Choices are local or remote."
                ::= { fc8gPerfEntry 1 }

        fc8gPerfShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the module is in."
                ::= { fc8gPerfEntry 2 }

        fc8gPerfSlot     OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the module is in."
                ::= { fc8gPerfEntry 3 }

        fc8gPerfState    OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The state of the FC8G module.  The states are:
                         online, offline, empty or loopback."
                ::= { fc8gPerfEntry 4 }

        fc8gPerfStatus   OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The status of the FC8G module.  This status represents
                         the status of the FC8G module and in general is
                         different from the status of the system."
                ::= { fc8gPerfEntry 5 }

        fc8gLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this module."
                ::= { fc8gPerfEntry 6 }

        fc8gAvailTime    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this module has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { fc8gPerfEntry 7 }

        fc8gErrFreeSecs  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this module has not experienced any alarms."
                ::= { fc8gPerfEntry 8 }

        -- Miscellaneous configuration elements
    
        sysAddCard      OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..10))
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Add card operation given type, shelf, slot, and
                         optionally sub card type.  The format is (type,shelf,
                         slot[,optional]).  If the fourth optional
                         parameter is present, for OCMITU/OCMU, its value should 
                         be 1 to indicate OCMITU/OCMU with CSIM; for MCMESC, its 
                         value should be 0 or 1 to indicate MPM will not overide or
                         will override the settings stored on MCMESC upon detecting
                         it.
                         Different types of card:
                         OCMU:       2 //with or without csim module
                         OCMI:       3 //with or without csim module
                         OFCM:       4
                         OFCD:       5
                         FADM:       6
                         MCMT1:      8
                         W4CD:      10
                         W2CM/D:    13
                         OSAM:      20
                         W4CM:      21
                         RSM:       22
                         UPSM:      23
                         OCME:      24
                         OCM10G:    27
                         OSAM-LP:   29
                         OSAM-HP:   30
                         MCMESC:    33
                         WFADM:     34
                         MCME1:     35
                         MD100-1:   36
                         MD100-40:  37
                         TAP:       38
                         MD100-5    39
                         MD100-10   40
                         OCM10GLR   41
                         BD-4       42
                         BP-10      43
                         DMM        45
                         BP-5       46
                         OSC        48
                         OCM2       49
                         OCM10GF    50
                         OCM2-4G    51
                         OET        52
                         UOB        53
                         FC8G       54
                         MD100P     55
                         CWDM_BD4   56

                         For example, to add a FADM card in shelf 1, slot 8,
                         this variable will be set to 6,1,8.
                         To add an OCMI card with colorsim module in shelf 1,
                         slot 7, this variable will be set to 3,1,7,1.
                         To add an MCMESC card with override option in shelf 1,
                         slot 7, this variable will be set to 33,1,7,1.
                         A get on this will return 0,0,0,0"
                ::= { systemConfig 1 } 

        sysAlarmCtrl    OBJECT-TYPE
                SYNTAX  INTEGER { enable(1), disable(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The Master Control for Alarms. Will enable or disable
                         all external and visual alarms of the system. The
                         default state is enable."
                ::= { systemConfig 2 } 

        sysAlarmCritical OBJECT-TYPE
                SYNTAX  INTEGER { on(1), off(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Turns on or off all external critical audible
                         and visual alarms."
                ::= { systemConfig  3 } 

        sysAlarmMajor   OBJECT-TYPE
                SYNTAX  INTEGER { on(1), off(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Turns on or off all external major and minor
                        audible and visual alarms."
                ::= { systemConfig 4 } 

        sysAlarmSerial  OBJECT-TYPE
                SYNTAX  INTEGER { enable(1), disable(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Enables or disables the flow of TL1 alarms to the
                         serial port."
                ::= { systemConfig 5 }

        sysAlarmAutoCutoff OBJECT-TYPE
                SYNTAX  INTEGER { enable(1), disable(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Enables or disables the AutoCutoff feature
                         for dry-contact alarm closures"			 
                ::= { systemConfig 6 }

        sysAddRoute     OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..20))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Add route operation given local shelf, local slot, destination
                         IP address and route Type.  The format is (shelf, slot, 
                         route Type, destination IP). 
                         Different types of route types are:

                         external Route: 1 (Route to an external non LuxN node)
                         internal Route: 2 (Route to a LuxN node in the network)

                         For example, to add an internal route to a LuxN node with IP address
                         192.162.6.65 from local shelf 1, slot 6 this variable would
                         be set to 1,6,3,192.162.6.65

                         For adding an external route, shelf & slot needs to be zero. For e.g
                         To add an external route to destination address 192.168.9.99,
                         this variable needs to be set to 0,0,192.168.9.99

                         A get on this will return 0,0,0,0
                         NO LONGER SUPPORTED, user now needs to use sysImnAddRoute"
                ::= { systemConfig 7 } 

        sysDeleteRoute  OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..20))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Delete  route operation given local shelf, local slot & destination
                         IP address .  The format is (shelf, slot, 
                         destination IP).  

                         For example, to delete a route to a LuxN node with IP address
                         192.162.6.65 from local shelf 1, slot 6 this variable would
                         be set to 1,6,192.162.6.65
                         A get on this will return 0,0,0
                         NO LONGER SUPPORTED, user now needs to use sysImnAddRoute"
                ::= { systemConfig 8 } 

        sysSwitchByPathId OBJECT-TYPE
                SYNTAX  PathIdName
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Initiate UPSR switching by Path ID."
                ::= { systemConfig 9 } 

        sysSwitchAll    OBJECT-TYPE
                SYNTAX  INTEGER { yes(1), no(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Switch all CC cards that have backup."          
                ::= { systemConfig 10 }

        sysAlarmMinor   OBJECT-TYPE
                SYNTAX  INTEGER { on(1), off(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Turns on or off all external minor
                         audible and visual alarms."
                ::= { systemConfig 11 }

        sysDelCfgDb OBJECT-TYPE
                SYNTAX  INTEGER { other(1), delete(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Action to delete configuration database. MPM would reboot
                         after the database is deleted. A get on it will return other"
                ::= { systemConfig 12 }

        sysImnAddRoute  OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..20))
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                       "Add route operation. It takes destination IP address, 
                        IP mask and the route metric.  
                        The format is (destination IP, IP mask, routeMetric). 

                        A get on this will return 0.0.0.0,0.0.0.0,0"
                ::= { systemConfig 13 }
                        
        sysImnDeleteRoute OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..20))
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                       "Delete route operation. It takes destination IP address 
                        and IP mask.
                        The format is (destination IP, IP mask=). 

                        A get on this will return 0.0.0.0,0.0.0.0"
                ::= { systemConfig 14 }  

    
        sysExtAlarmInputTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF SysExtAlarmInputEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the input information for each
                         external alarm indicator"
                ::= { systemConfig 17 }

       sysExtAlarmInputEntry OBJECT-TYPE
                SYNTAX  SysExtAlarmInputEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { sysExtAlarmInputId }
                ::= { sysExtAlarmInputTable 1 }

        SysExtAlarmInputEntry ::=
                SEQUENCE
                {
                        sysExtAlarmInputId      INTEGER,
                        sysExtAlarmInput        INTEGER,
                        sysExtAlarmInputName    AlarmType
                }

        sysExtAlarmInputId OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Id of an external alarm indicator. Valid
                         values are: 1 to 6"
                ::= { sysExtAlarmInputEntry 1 }

        sysExtAlarmInput OBJECT-TYPE
                SYNTAX  INTEGER { off(1), minor(2), major(3), critical(4), na(5) }                           
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Configurable value for an external alarm indicator.
                         Default value is off. For the chassis with old sensor board,
                         the value is na and is not settable."
                ::= { sysExtAlarmInputEntry 2 }

        sysExtAlarmInputName OBJECT-TYPE
                SYNTAX  AlarmType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "User configurable name for an external alarm input indicator.
                         For the chassis with old sensor board, the value is na
                         and is not settable."
                ::= { sysExtAlarmInputEntry 3 }

        sysAudioAlarm   OBJECT-TYPE
                SYNTAX  INTEGER { brief(1), test(2), continous(3), off(4), na(5) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Mode for audio alarm.
                         Default is off. For non-carrier-class chassis, it is na"
                ::= { systemConfig 18  }  

        sysAudioAlarmSeverity OBJECT-TYPE
                SYNTAX  INTEGER { major(1), critical(2), minor(3), na(4) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Controls for audio alarm. When the control is set to
                         minor, it will go off for all minor and up
                         alarms. Default is major. For non-carrier-class chassis,
                         it is na. These control only make sense for
                         audio alarm in brief or continous mode"
                ::= { systemConfig 19  }
        
        sysRdbcopy      OBJECT-TYPE
                SYNTAX  INTEGER { other(1), copydb(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Forces a database copy to the standby MPM.  Reading this
                         element will always return 'other'. This element can
                         only be set to 'copydb'.  If the standby MPM is present
                         then a database copy will be initiated, otherwise an 
                         error will be return."
                ::= { systemConfig 20  }

        sysRdbcopyStatus OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Displays the percentage done for forced database copies.
                         No value is returned if a forced database copy is not
                         in progress."
                ::= { systemConfig 21  }

        sysSDMRequestsQueued OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Displays the number of requests in the SDM queue."
                ::= { systemConfig 22 }

        sysModuleupdateJobsWaiting OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Displays the number of module updates jobs from the
                         current request that must wait until one or more of
                         the jobs progressing completes.  This element will
                         only be returned if one or more module update jobs
                         are in progress."
                ::= { systemConfig 23 }

        sysModuleupdateJobsTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF SysModuleupdateJobsEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table defines the module update jobs in progress.
                         Table entries will only be reutrned if one for more
                         module update jobs are in progress."
                ::= { systemConfig 24 }

       sysModuleupdateJobsEntry OBJECT-TYPE
                SYNTAX  SysModuleupdateJobsEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { sysModupdShelf, sysModupdSlot, sysModupdLocation, sysModupdRmtStation }
                ::= { sysModuleupdateJobsTable 1 }

        SysModuleupdateJobsEntry ::=
                SEQUENCE
                {
                        sysModupdShelf          INTEGER,
                        sysModupdSlot           INTEGER,
                        sysModupdLocation       CardLocation,
                        sysModupdRmtStation     INTEGER,
                        sysModupdCardtype       CardType,
                        sysModupdPercentDone    INTEGER
                }

        sysModupdShelf OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Shelf of the module being updated.  For remote updates
                         this will be the shelf of the local module through the
                         update occurs."
                ::= { sysModuleupdateJobsEntry 1 }

        sysModupdSlot OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Slot of the module being updated.  For remote updates
                         this will be the slot of the local module through the
                         update occurs."
                ::= { sysModuleupdateJobsEntry 2 }

        sysModupdLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Location (local or remote) of the module being updated"
                ::= { sysModuleupdateJobsEntry 3 }

        sysModupdRmtStation OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Remote station of the module being updated"
                ::= { sysModuleupdateJobsEntry 4 }

        sysModupdCardtype OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Type of module being updated."
                ::= { sysModuleupdateJobsEntry 5 }

        sysModupdPercentDone OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Percentage of update completed."
                ::= { sysModuleupdateJobsEntry 6 }

        sysSNMPKeepaliveEnable OBJECT-TYPE
                SYNTAX  INTEGER {enabled(1), disabled(2)}
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Enable or disable SNMP keep alive functionality."
                ::= { systemConfig 25 }

        sysSNMPKeepaliveInterval OBJECT-TYPE
                SYNTAX  INTEGER (1..1440)
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Set the SNMP keep alive interval in minutes."
                ::= { systemConfig 26 }
       
        -- The elements in the systemPerf subgroup of the current subgroup

        sysStatus       OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The global status of the system as computed based on
                         the traps (events) that are generated.  Choices are:
                         Critical, Major, Minor or Normal."
                ::= { systemPerf 1 }

        sysClearStatus  OBJECT-TYPE
                SYNTAX  ResetType
                ACCESS  not-accessible 
                STATUS  mandatory
                DESCRIPTION
                        "Reset the system state to Normal.  The value of reset
                         means set the state to Normal.  A get on this will
                         always return other. 
                         Note: This element is now made not-accessible as sysStatus
                         is now a read-only element"
                ::= { systemPerf 2 }

        sysClearCounters OBJECT-TYPE
                SYNTAX  ResetType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Reset all performance counters in this 15 minutes time
                         interval to zero.  The value of reset means to reset the
                         counters to zero.  A get on this will always return
                         other."
                ::= { systemPerf 3 }

        sysLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last system boot.  This time
                         represents the boot time of a CP card.  It is also
                         anonymous with the power-up cycle of the chassis."
                ::= { systemPerf 4 }

        sysAvailTime    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that the system has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900),
                         but, if the system has been reboot in the last 15
                         minutes interval, then it represents the number of
                         seconds the system has been up.  The criteria for the
                         system available time is having at least one CP
                         running with atmost non-service affecting minor
                         alarm system status"
                ::= { systemPerf 5 }

        sysErrFreeSecs  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that the device has not experienced any alarms.  This
                         counter is across all cards in the chassis.  The
                         system must be in Normal status for this counter to
                         be incremented."
                ::= { systemPerf 6 }

      sysExhaustTemperature OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Temperature of the Chassis.  Units of dgree centigrade."
                ::= { systemPerf 7 }

        -- The elements in the downloadPerf subgroup of the current subgroup

        dlStatus        OBJECT-TYPE
                SYNTAX  DownloadStatus
                ACCESS  read-write 
                STATUS  mandatory
                DESCRIPTION
                        "The global status of the download task.  The download task 
                         (download to the device) is either ftp_inprogress, module 
                         update inprogrss or currently idle.  Since only one download 
                         at the time is handled by the system, this flag is set to 
                         inprogress as soon as any download starts.  
                         It is reset back to idle when the download is completed.  
                         This flag is set to idle on system startup.  This flag 
                         can be remotely set to idle if a previous FTP download 
                         was interrupted."
                ::= { downloadPerf 1 }

        dlOkDownloads   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The number of successful downloads in this time
                         interval (15 minutes)."
                ::= { downloadPerf 2 }

        dlBadDownloads  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The number of failed downloads in this time
                         interval (15 minutes)."
                ::= { downloadPerf 3 }

        dlLongestTime   OBJECT-TYPE
                SYNTAX  Gauge
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Longest time for any download, in seconds, in this
                         time interval (15 minutes)."
                ::= { downloadPerf 4 }

        dlLongestSize   OBJECT-TYPE
                SYNTAX  Gauge
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Longest download size for any download, in bytes, in
                         this time interval (15 minutes)."
                ::= { downloadPerf 5 }

        -- The elements in the cpPerf subgroup of the current subgroup

        cpNumEvents     OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of events received by the active CP in
                         this time slot (15 minutes)."
                ::= { cpPerf 1 }

        cpTrapsSent     OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of traps sent by the active CP in
                         this time slot (15 minutes)."
                ::= { cpPerf 2 }

        cpSNMPCmdsRcvd  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of SNMP commands received by the active
                         CP in this time slot (15 minutes)."
                ::= { cpPerf 3 }

        cpCounterFlag   OBJECT-TYPE
                SYNTAX  FlagType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Turns software counters On or Off."
                ::= { cpPerf 4 }

        cpCntrTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF CpCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entry of the software counters.  It is only 
                         applicable to the active MPM card."
                ::= { cpPerf 5 }

        cpCntrEntry     OBJECT-TYPE
                SYNTAX  CpCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { cpCntrShelf, cpCntrSlot, cpCntrType }
                ::= { cpCntrTable 1 }

        CpCntrEntry     ::=
                SEQUENCE 
                {
                        cpCntrShelf             CardShelf,
                        cpCntrSlot              INTEGER,
                        cpCntrType              INTEGER,
                        cpTotPktSent            Counter,
                        cpTotPktRcvd            Counter,
                        cpBadPktRcvd            Counter,
                        cpTotBadTrans           Counter,
                        cpBytesSent             Counter,
                        cpBytesRcvd             Counter,
                        cpMsgsDlvrd             Counter,
                        cpBufAllocFail          Counter,
                        cpEcbAllocFail          Counter,
                        cpClearCntrs            ResetType
                }

        cpCntrShelf     OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2.
                         The system automatically determines the right value
                         for this entry based on the value of the current
                         active CP card."
                ::= { cpCntrEntry 1 }

        cpCntrSlot      OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  Valid
                         values are: 1 to 2.  The system automatically
                         determines the right value for this entry based
                         on the value of the current active CP card."
                ::= { cpCntrEntry 2 }

        cpCntrType      OBJECT-TYPE
                SYNTAX  INTEGER { spi(1) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The type of the software counter data in this row.
                         The data is collected for the SPI data channels."
                ::= { cpCntrEntry 3 }

        cpTotPktSent    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets sent over the given data
                         channel."
                ::= { cpCntrEntry 4 }

        cpTotPktRcvd    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets received over the given
                         data channel."
                ::= { cpCntrEntry 5 }

        cpBadPktRcvd    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data packets received over the given
                         data channel."
                ::= { cpCntrEntry 6 }

        cpTotBadTrans   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data transmissions over the given
                         data channel."
                ::= { cpCntrEntry 7 }

        cpBytesSent     OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of bytes sent over the given
                         data channel."
                ::= { cpCntrEntry 8 }

        cpBytesRcvd     OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of data bytes received over the given
                         data channel."
                ::= { cpCntrEntry 9 }

        cpMsgsDlvrd     OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of complete messages delivered over the
                         given data channel."
                ::= { cpCntrEntry 10 }

        cpBufAllocFail  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of buffer allocation failures for the given
                         data channel."
                ::= { cpCntrEntry 11 }

        cpEcbAllocFail  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of Event Control Block allocation failures
                         for the given data channel."
                ::= { cpCntrEntry 12 }

        cpClearCntrs    OBJECT-TYPE
                SYNTAX  ResetType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "If the value is reset, all software counters for this
                         15 minute interval are reset to zero.  A get on this
                         will always return other"
                ::= { cpCntrEntry 13 }

        cpPerfTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF CpPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each communication processor"
                ::= { cpPerf 6 }

        cpPerfEntry     OBJECT-TYPE
                SYNTAX  CpPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { cpPerfShelf, cpPerfSlot }
                ::= { cpPerfTable 1 }

        CpPerfEntry     ::=
                SEQUENCE
                {
                        cpPerfShelf             CardShelf,
                        cpPerfSlot              INTEGER,
                        cpPerfMode              RedundancyMode,
                        cpPerfState             CardState,
                        cpPerfStatus            CardStatus,
                        cpLastBootTime          DateAndTime,
                        cpAvailTime             Counter,
                        cpErrFreeSecs           Counter
                }

        cpPerfShelf     OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2"
                ::= { cpPerfEntry 1 }

        cpPerfSlot      OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  Valid
                         values are: 1 to 3"
                ::= { cpPerfEntry 2 }

        cpPerfMode      OBJECT-TYPE
                SYNTAX  RedundancyMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The valid types are: active CP or standby CP"
                ::= { cpPerfEntry 3 }

        cpPerfState     OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The status of the communication card.  The status'
                         are: online, offline, empty, loopback or diagnostics."
                ::= { cpPerfEntry 4 }

        cpPerfStatus    OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The status of the communication processor.  This
                         status represents the state of the communication
                         processor and in general is different from the
                         status of the system."
                ::= { cpPerfEntry 5 }

        cpLastBootTime  OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this CP."
                ::= { cpPerfEntry 6 }

        cpAvailTime     OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this CP has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { cpPerfEntry 7 }

        cpErrFreeSecs   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this CP has not experienced any alarms."
                ::= { cpPerfEntry 8 }

        -- The elements in the ccPerf subgroup of the current subgroup

        ccNumEvents     OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of events received for all CC's in
                         this time slot (15 minutes)."
                ::= { ccPerf 1 }

        ccCntrTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF CcCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entry for the software counters."
                ::= { ccPerf 2 }

        ccCntrEntry     OBJECT-TYPE
                SYNTAX  CcCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { ccCntrLocation, ccCntrShelf, ccCntrSlot, ccCntrType }
                ::= { ccCntrTable 1 }

        CcCntrEntry     ::=
                SEQUENCE
                {
                        ccCntrLocation          CardLocation,
                        ccCntrShelf             CardShelf,
                        ccCntrSlot              INTEGER,
                        ccCntrType              INTEGER,
                        ccCounterFlag           FlagType,
                        ccTotPktSent            Counter,
                        ccTotPktRcvd            Counter,
                        ccBadPktRcvd            Counter,
                        ccTotBadTrans           Counter,
                        ccBytesSent             Counter,
                        ccBytesRcvd             Counter,
                        ccMsgsDlvrd             Counter,
                        ccBufAllocFail          Counter,
                        ccEcbAllocFail          Counter,
                        ccClearCntrs            ResetType
                }

        ccCntrLocation  OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the CC card.  The values are: Local
                         or Remote.  The system automatically determines the
                         right value for this entry based on the known
                         CC cards."
                ::= { ccCntrEntry 1 }

        ccCntrShelf     OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2.
                         The system automatically determines the right value
                         for this entry based on the known (available) CC
                         cards."
                ::= { ccCntrEntry 2 }

        ccCntrSlot      OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  Valid
                         values are: 1 to 17.  The system automatically
                         determines the right value for this entry based
                         on the known (available) CC cards."
                ::= { ccCntrEntry 3 }

        ccCntrType      OBJECT-TYPE
                SYNTAX  INTEGER { spi(1), iwm(2) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The type of the software counter data in this row.
                         The data is collected for the SPI data channels."
                ::= { ccCntrEntry 4 }

        ccCounterFlag   OBJECT-TYPE
                SYNTAX  FlagType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Turns software counters, both On or both Off for this CC.
                         When set to Off, both counters statistic information will
                         be cleared."
                ::= { ccCntrEntry 5 }

        ccTotPktSent    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets sent over the given data
                         channel."
                ::= { ccCntrEntry 6 }

        ccTotPktRcvd    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets received over the given
                         data channel."
                ::= { ccCntrEntry 7 }

        ccBadPktRcvd    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data packets received over the given
                         data channel."
                ::= { ccCntrEntry 8 }

        ccTotBadTrans   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data transmissions over the given
                         data channel."
                ::= { ccCntrEntry 9 }

        ccBytesSent     OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of bytes sent over the given
                         data channel."
                ::= { ccCntrEntry 10 }

        ccBytesRcvd     OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of data bytes received over the given
                         data channel."
                ::= { ccCntrEntry 11 }

        ccMsgsDlvrd     OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of complete messages delivered over the
                         given data channel."
                ::= { ccCntrEntry 12 }

        ccBufAllocFail  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of buffer allocation failures for the given
                         data channel."
                ::= { ccCntrEntry 13 }

        ccEcbAllocFail  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of Event Control Block allocation failures
                         for the given data channel."
                ::= { ccCntrEntry 14 }

        ccClearCntrs    OBJECT-TYPE
                SYNTAX  ResetType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "If the value is reset, all software counters for this
                         15 minute interval are reset to zero.  A get on this
             will always return other"
                ::= { ccCntrEntry 15 }

        ccPerfTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF CcPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each channel card"
                ::= { ccPerf 3 }

        ccPerfEntry     OBJECT-TYPE
                SYNTAX  CcPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { ccPerfLocation, ccPerfShelf, ccPerfSlot }
                ::= { ccPerfTable 1 }

        CcPerfEntry     ::=
                SEQUENCE
                {
                        ccPerfLocation          CardLocation,
                        ccPerfShelf             CardShelf,
                        ccPerfSlot              INTEGER,
                        ccPerfState             CardState,
                        ccPerfStatus            CardStatus,
                        ccLastBootTime          DateAndTime,
                        ccAvailTime             Counter,
                        ccErrFreeSecs           Counter,
                        ccBiasCurrent           INTEGER,
                        ccModulation            INTEGER,
                        ccApc                   INTEGER,
                        ccIwmModulation         INTEGER,
                        ccLaserOnOff            FlagType,
                        ccTemperature           Gauge,
                        ccIntensity             Gauge,
                        ccSignalStrength        Gauge,
                        ccLossOfLight           Boolean,
                        ccSignalDetect          Boolean,
                        ccRefClock              INTEGER,
                        ccClockDiv              INTEGER,
                        ccLinkTxPwrStatus       INTEGER,
                        ccLinkRxSigStrStatus    INTEGER,
                        ccCpeRxSigDetect        INTEGER,
                        ccLinkIWMStatus         INTEGER,
                        ccLinkSummaryStatus     INTEGER,
                        ccProtectionMode        INTEGER,
                        ccLinkRxSigStr          DisplayString
                }

        ccPerfLocation  OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card.  Valid choices are Local
                         or Remote.  The system automatically selects this
                         value based on the known (available) CC cards."
                ::= { ccPerfEntry 1 }

        ccPerfShelf     OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 10"
                ::= { ccPerfEntry 2 }

        ccPerfSlot      OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  Valid
                         values are: 4 to 42"
                ::= { ccPerfEntry 3 }

        ccPerfState     OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The state of the channel card.  The states'
                         are: online, offline, empty, loopback or diagnostics."
                ::= { ccPerfEntry 4 }

        ccPerfStatus    OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The status of the channel card.  This
                         status represents the status of the communication
                         processor and in general is different from the
                         status of the system."
                ::= { ccPerfEntry 5 }

        ccLastBootTime  OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this card."
                ::= { ccPerfEntry 6 }

        ccAvailTime     OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this CC has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { ccPerfEntry 7 }

        ccErrFreeSecs   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this CC has not experienced any alarms."
                ::= { ccPerfEntry 8 }

        ccBiasCurrent   OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Bias current for the optical laser."
                ::= { ccPerfEntry 9 }

        ccModulation    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The frequency modulation for the optical laser."
                ::= { ccPerfEntry 10 }

        ccApc           OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The APC value."
                ::= { ccPerfEntry 11 }

        ccIwmModulation OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The frequency modulation for the IWM channel."
                ::= { ccPerfEntry 12 }

        ccLaserOnOff    OBJECT-TYPE
                SYNTAX  FlagType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The laser On/Off flag."
                ::= { ccPerfEntry 13 }

        ccTemperature   OBJECT-TYPE
                SYNTAX  Gauge
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The current temperature, or the operating temperature
                         of the optical device."
                ::= { ccPerfEntry 14 }

        ccIntensity     OBJECT-TYPE
                SYNTAX  Gauge
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The intensity of the optical light."
                ::= { ccPerfEntry 15 }

        ccSignalStrength OBJECT-TYPE
                SYNTAX  Gauge
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The current signal strength for the optical path."
                ::= { ccPerfEntry 16 }

        ccLossOfLight   OBJECT-TYPE
                SYNTAX  Boolean
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "If set to true, no laser light is present.  If set to
                         false, no loss of light has occurred."
                ::= { ccPerfEntry 17 }

        ccSignalDetect  OBJECT-TYPE
                SYNTAX  Boolean
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "If set to true, signal is detected.  If set to false,
                         no signal is present. Replaced with ccCpeRxSigDetect"
                ::= { ccPerfEntry 18 }

        ccRefClock      OBJECT-TYPE
                SYNTAX  INTEGER {   en1660(1), en1944(2), en1953(3) }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The value of the reference clock in decimal notation.
                         For a given value, like 1660, the actual value is
                         16.60-EN.  In otherwords, assume a two digit decimal
                         point, plus any appropriate scaling factor."
                ::= { ccPerfEntry 19 }

        ccClockDiv      OBJECT-TYPE
                SYNTAX  INTEGER { dout-1250(1), dout-622(2), dout-155(3) }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The clock divisor.  Values are 1250, 622 or 155 in the
                         appropriate clock frequency scale."
                ::= { ccPerfEntry 20 }

        ccLinkTxPwrStatus OBJECT-TYPE
                SYNTAX  INTEGER { ok(1), fault(2) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "This indicates whether the link transmit power is within the
                         normal range of operation."
                ::= { ccPerfEntry 21 }

        ccLinkRxSigStrStatus OBJECT-TYPE
                SYNTAX  INTEGER { ok(1), fault(2) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "This indicates whether the link's receive signal is within the
                         normal range of operation."
                ::= { ccPerfEntry 22 }

        ccCpeRxSigDetect OBJECT-TYPE
                SYNTAX  INTEGER { yes(1), no(2)}
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "This indicates whether there is presence of CPE receive signal"
                ::= { ccPerfEntry 23 }

        ccLinkIWMStatus OBJECT-TYPE
                SYNTAX  INTEGER { ok(1), error(2), notApplicable(3) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "This indicates the current status of IWM. This value is only
                         applicable to remote OCMs"
                ::= { ccPerfEntry 24 }

        ccLinkSummaryStatus      OBJECT-TYPE
                SYNTAX  INTEGER { ok(1), fault(2), notApplicable(3) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "This is the result of a logical and operation of all the individual
                         link status. If any of the attributes is N/A, except for the local
                         local IWM status, this value is N/A"
                ::= { ccPerfEntry 25 }

        ccProtectionMode OBJECT-TYPE
                SYNTAX  INTEGER {  working(1),  protection(2), na(3) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "UPSR Protection Mode:  active, standby and n/a."
                ::= { ccPerfEntry 26 }

        ccLinkRxSigStr  OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Link's received signal strength in dBm."
                ::= { ccPerfEntry 27 }

        -- The elements in the muxPerf subgroup of the current subgroup

        muxNumEvents    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         MUX's in this time slot (15 minutes)."
                ::= { muxPerf 1 }
    

        muxPerfTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF MuxPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each mux/demux card"
                ::= { muxPerf 2 }

        muxPerfEntry    OBJECT-TYPE
                SYNTAX  MuxPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { muxPerfLocation, muxPerfShelf, muxPerfSlot }
                ::= { muxPerfTable 1 }

        MuxPerfEntry    ::=
                SEQUENCE
                {
                        muxPerfLocation         CardLocation,
                        muxPerfShelf            CardShelf,
                        muxPerfSlot             INTEGER,
                        muxType                 INTEGER,
                        muxPerfState            CardState,
                        muxPerfStatus           CardStatus,
                        muxLastBootTime         DateAndTime,
                        muxAvailTime            Counter,
                        muxErrFreeSecs          Counter
                }

        muxPerfLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card.  Choices are local or
                         remote."
                ::= { muxPerfEntry 1 }

        muxPerfShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 10"
                ::= { muxPerfEntry 2 }

        muxPerfSlot     OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  Valid
                         values are: 1 to 42"
                ::= { muxPerfEntry 3 }

        muxType         OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The type of the mux.  The choices are: mux or demux."
                ::= { muxPerfEntry 4 }

        muxPerfState    OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The state of the mux card.  The states are:
                         online, offline, empty, loopback or diag."
                ::= { muxPerfEntry 5 }

        muxPerfStatus   OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The status of the mux card.  This status represents
                         the status of the mux card and in general is
                         different from the status of the system."
                ::= { muxPerfEntry 6 }

        muxLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this card."
                ::= { muxPerfEntry 7 }

        muxAvailTime    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this Mux has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { muxPerfEntry 8 }

        muxErrFreeSecs  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this mux has not experienced any alarms."
                ::= { muxPerfEntry 9 }

        -- The elements in the psPerf subgroup of the current subgroup

        psNumEvents     OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         Power Supplies in this time slot (15 minutes)."
                ::= { psPerf 1 }

        psVoltageLevel3pt4Volt OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..10))
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Voltage Level of the 3.4 V power supply."  
                ::= { psPerf 2 }

        psVoltageLevel5pt1Volt OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..10))
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Voltage Level of the 5.1 V power supply."  
                ::= { psPerf 3 }

        psVoltageLevel12Volt OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..10))
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Voltage Level of the 12 V power supply."  
                ::= { psPerf 4 }

        psPerfTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF PsPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each power supply card"
                ::= { psPerf 5 }

        psPerfEntry     OBJECT-TYPE
                SYNTAX  PsPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { psPerfID }
                ::= { psPerfTable 1 }

        PsPerfEntry     ::=
                SEQUENCE
                {
                        psPerfID                INTEGER,
                        psPerfType              INTEGER,
                        psPerfState             INTEGER,
                        psPerfStatus            CardStatus
                }

        psPerfID        OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The module ID where the PS is plugged in."
                ::= { psPerfEntry 1 }

        psPerfType      OBJECT-TYPE
                SYNTAX  INTEGER { psDC(1), psAC(2), unknown(3) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The type of the power supply."
                ::= { psPerfEntry 2 }


        psPerfState     OBJECT-TYPE
                SYNTAX  INTEGER  { psEmpty(1), psOK(2), psFailed(3), psDegrade(4) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The state of the power supply module."
                ::= { psPerfEntry 3 }

        psPerfStatus    OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The status of the power supply module.  This status
                         represents the status of the ps module and in general is
                         different from the status of the system."
                ::= { psPerfEntry 4 }

        psVoltageLevelFeedA OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..10))
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                    "Voltage Level of the -48 VDC input from Feed A."  
                ::= { psPerf 6 }

        psVoltageLevelFeedB OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..10))
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Voltage Level of the -48 VDC input from Feed B."  
                ::= { psPerf 7 }

        psBreakerConditionFeedA OBJECT-TYPE
                SYNTAX  INTEGER {   open(1), closed(2), na(3) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "State of Feed A breaker."  
                ::= { psPerf 8 }

        psPerfStatusFeedA OBJECT-TYPE
                SYNTAX  INTEGER { feedOK(1), feedFAILED(2), feedUNKNOWN(3), na(4) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "State of Feed A breaker. Failed if it
                         goes into shutdown condition
                         Unknown if the corresponding breaker
                         is open"  
                ::= { psPerf 9 }

        psBreakerConditionFeedB OBJECT-TYPE
                SYNTAX  INTEGER { open(1), closed(2), na(3) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "State of Feed B breaker."  
                ::= { psPerf 10 }

        psPerfStatusFeedB OBJECT-TYPE
                SYNTAX  INTEGER { feedOK(1), feedFAILED(2), feedUNKNOWN(3), na(4) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "State of Feed B.
                         Failed if it goes into shutdown condition
                         Unknown if the corresponding breaker is open"
                ::= { psPerf 11 }

        -- The elements in the fadmPerf subgroup of the current subgroup

        fadmNumEvents   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         MUX's in this time slot (15 minutes)."
                ::= { fadmPerf 1 }

        fadmPerfTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF FadmPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each fadm card"
                ::= { fadmPerf 2 }

        fadmPerfEntry   OBJECT-TYPE
                SYNTAX  FadmPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { fadmPerfLocation, fadmPerfShelf, fadmPerfSlot }
                ::= { fadmPerfTable 1 }

        FadmPerfEntry   ::=
                SEQUENCE
                {
                        fadmPerfLocation        CardLocation,
                        fadmPerfShelf           CardShelf,
                        fadmPerfSlot            INTEGER,
                        fadmPerfState           CardState,
                        fadmPerfStatus          CardStatus,
                        fadmLastBootTime        DateAndTime,
                        fadmAvailTime           Counter,
                        fadmErrFreeSecs         Counter
                }

        fadmPerfLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card.  Choices are local or
                         remote."
                ::= { fadmPerfEntry 1 }

        fadmPerfShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 10"
                ::= { fadmPerfEntry 2 }

        fadmPerfSlot    OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  Valid
                         values are: 1 to 42"
                ::= { fadmPerfEntry 3 }

        fadmPerfState   OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The status of the fadm card.  The states are:
                         online, offline, empty, loopback or diag."
                ::= { fadmPerfEntry 4 }

        fadmPerfStatus  OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The status of the fadm card.  This status represents
                         the status of the fadm card and in general is
                         different from the status of the system."
                ::= { fadmPerfEntry 5 }

        fadmLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this card."
                ::= { fadmPerfEntry 6 }

        fadmAvailTime   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this fadm card has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { fadmPerfEntry 7 }

        fadmErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this fadm card has not experienced any alarms."
                ::= { fadmPerfEntry 8 }

        -- The elements in the oppmPerf subgroup of the current subgroup

        oppmNumEvents   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         OPPM's in this time slot (15 minutes)."
                ::= { oppmPerf 1 }

        oppmPerfTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF OppmPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each oppm card"
                ::= { oppmPerf 2 }

       oppmPerfEntry    OBJECT-TYPE
                SYNTAX  OppmPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { oppmPerfLocation, oppmPerfShelf, oppmPerfSlot }
                ::= { oppmPerfTable 1 }

        OppmPerfEntry   ::=
                SEQUENCE
                {
                        oppmPerfLocation        CardLocation,
                        oppmPerfShelf           CardShelf,
                        oppmPerfSlot            INTEGER,
                        oppmPerfState           CardState,
                        oppmPerfStatus          CardStatus,
                        oppmLinkAState          INTEGER,
                        oppmLinkAStatus         INTEGER,
                        oppmLinkBState          INTEGER,
                        oppmLinkBStatus         INTEGER,
                        oppmLastBootTime        DateAndTime,
                        oppmAvailTime           Counter,
                        oppmErrFreeSecs         Counter,
                        oppmWorkingPower        INTEGER,
                        oppmProtectPower        INTEGER
                }

        oppmPerfLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card.  Choices are local or remote."
                ::= { oppmPerfEntry 1 }

        oppmPerfShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 10"
                ::= { oppmPerfEntry 2 }

        oppmPerfSlot    OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  Valid
                         values are: 4 to 42"
                ::= { oppmPerfEntry 3 }


        oppmPerfState   OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The state of the oppm card.  The states are:
                         online, offline."
                ::= { oppmPerfEntry 4 }

        oppmPerfStatus  OBJECT-TYPE
                SYNTAX  CardStatus 
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The status of the oppm card.  This status represents
                         the status of the oppm card and in general is
                         different from the status of the system."
                ::= { oppmPerfEntry 5 }

        oppmLinkAState   OBJECT-TYPE
                SYNTAX  INTEGER { linked(1), notLinked(2), unknown(3) }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The state of the oppm card.  The states are:
                         linked, notLinked."
                ::= { oppmPerfEntry 6 }

        oppmLinkAStatus OBJECT-TYPE
                SYNTAX  INTEGER { active(1), standby(2), hibernation(3) }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The status of the card channel.  This status represents
                         the status of the link A of the card and in general is
                         different from the status of the card."
                ::= { oppmPerfEntry 7 }

        oppmLinkBState  OBJECT-TYPE
                SYNTAX  INTEGER { linked(1), notLinked(2), unknown(3) }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The state of the oppm card link B.  The states are:
                         linked, notLinked."
                ::= { oppmPerfEntry 8 }

        oppmLinkBStatus OBJECT-TYPE
                SYNTAX  INTEGER { active(1), standby(2), hibernation(3) }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The status of the card channel.  This status represents
                         the status of the link B of the card and in general is
                         different from the status of the card."
                ::= { oppmPerfEntry 9 }

        oppmLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this card."
                ::= { oppmPerfEntry 10 }

        oppmAvailTime   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this oppm card has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { oppmPerfEntry 11 }

        oppmErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this oppm card has not experienced any alarms."
                ::= { oppmPerfEntry 12 }

        oppmWorkingPower OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "working power displayed in dBm unit"
                ::= { oppmPerfEntry 13 }

        oppmProtectPower OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "protect power displayed in dBm unit"
                ::= { oppmPerfEntry 14 }

        -- The elements in the mcmPerf subgroup of the current subgroup

        mcmNumEvents    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of events received for all mcmt1's/mcme1's in
                         this time slot (15 minutes)."
                ::= { mcmPerf 1 }

        mcmCntrTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF McmCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entry for the software counters."
                ::= { mcmPerf 2 }

        mcmCntrEntry    OBJECT-TYPE
                SYNTAX  McmCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { mcmCntrLocation, mcmCntrShelf, mcmCntrSlot, mcmCntrType }
                ::= { mcmCntrTable 1 }

        McmCntrEntry    ::=
                SEQUENCE
                {
                        mcmCntrLocation         CardLocation,
                        mcmCntrShelf            CardShelf,
                        mcmCntrSlot             INTEGER,
                        mcmCntrType             INTEGER,
                        mcmCounterFlag          FlagType,
                        mcmTotPktSent           Counter,
                        mcmTotPktRcvd           Counter,
                        mcmBadPktRcvd           Counter,
                        mcmTotBadTrans          Counter,
                        mcmBytesSent            Counter,
                        mcmBytesRcvd            Counter,
                        mcmMsgsDlvrd            Counter,
                        mcmBufAllocFail         Counter,
                        mcmEcbAllocFail         Counter,
                        mcmClearCntrs           ResetType
                }

        mcmCntrLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the mcmt1/mcme1 card.  The values are: Local
                         or Remote.  The system automatically determines the
                         right value for this entry based on the known
                         mcmt1/mcme1 cards."
                ::= { mcmCntrEntry 1 }

        mcmCntrShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 3.
                         The system automatically determines the right value
                         for this entry based on the known (available) mcmt1/mcme1
                         cards."
                ::= { mcmCntrEntry 2 }

        mcmCntrSlot     OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  Valid
                         values are: 1 to 21.  The system automatically
                         determines the right value for this entry based
                         on the known (available) mcmt1/mcme1 cards."
                ::= { mcmCntrEntry 3 }

        mcmCntrType     OBJECT-TYPE
                SYNTAX  INTEGER { spi(1), iwm(2) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The type of the software counter data in this row.
                         The data is collected for the SPI data channels."
                ::= { mcmCntrEntry 4 }

        mcmCounterFlag  OBJECT-TYPE
                SYNTAX  FlagType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Turns software counters On or Off for this mcmt1/mcme1."
                ::= { mcmCntrEntry 5 }

        mcmTotPktSent   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets sent over the given data
                         channel."
                ::= { mcmCntrEntry 6 }

        mcmTotPktRcvd   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets received over the given
                         data channel."
                ::= { mcmCntrEntry 7 }

        mcmBadPktRcvd   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data packets received over the given
                         data channel."
                ::= { mcmCntrEntry 8 }

        mcmTotBadTrans  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data transmissions over the given
                         data channel."
                ::= { mcmCntrEntry 9 }

        mcmBytesSent    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of bytes sent over the given
                         data channel."
                ::= { mcmCntrEntry 10 }

        mcmBytesRcvd    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of data bytes received over the given
                         data channel."
                ::= { mcmCntrEntry 11 }

        mcmMsgsDlvrd    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of complete messages delivered over the
                         given data channel."
                ::= { mcmCntrEntry 12 }

        mcmBufAllocFail OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of buffer allocation failures for the given
                         data channel."
                ::= { mcmCntrEntry 13 }

        mcmEcbAllocFail OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of Event Control Block allocation failures
                         for the given data channel."
                ::= { mcmCntrEntry 14 }

        mcmClearCntrs   OBJECT-TYPE
                SYNTAX  ResetType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "If the value is reset, all software counters for this
                         15 minute interval are reset to zero.  A get on this
             will always return other"
                ::= { mcmCntrEntry 15 }

        mcmPerfTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF McmPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each mcmt1/mcme1 card"
                ::= { mcmPerf 3 }

        mcmPerfEntry    OBJECT-TYPE
                SYNTAX  McmPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { mcmPerfLocation, mcmPerfShelf, mcmPerfSlot }
                ::= { mcmPerfTable 1 }

        McmPerfEntry    ::=
                SEQUENCE
                {
                        mcmPerfLocation         CardLocation,
                        mcmPerfShelf            CardShelf,
                        mcmPerfSlot             INTEGER,
                        mcmPerfState            CardState,
                        mcmPerfStatus           CardStatus,
                        mcmLastBootTime         DateAndTime,
                        mcmAvailTime            Counter,
                        mcmErrFreeSecs          Counter,
                        mcmBiasCurrent          INTEGER,
                        mcmModulation           INTEGER,
                        mcmApc                  INTEGER,
                        mcmIwmModulation        INTEGER,
                        mcmLaserOnOff           FlagType,
                        mcmTemperature          Gauge,
                        mcmIntensity            Gauge,
                        mcmSignalStrength       Gauge,
                        mcmLossOfLight          Boolean,
                        mcmSignalDetect         Boolean
                }

        mcmPerfLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card.  Valid choices are Local
                         or Remote.  The system automatically selects this
                         value based on the known (available) mcmt1/mcme1 cards."
                ::= { mcmPerfEntry 1 }

        mcmPerfShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 3"
                ::= { mcmPerfEntry 2 }

        mcmPerfSlot     OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  Valid
                         values are: 1 to 21"
                ::= { mcmPerfEntry 3 }

        mcmPerfState    OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The state of the mcmt1/mcme1 card.  The states' are:
                         online, offline, empty, loopback or diagnostics."
                ::= {mcmPerfEntry 4 }

        mcmPerfStatus   OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The status of the channel card.  This
                         status represents the status of the communication
                         processor and in general is different from the
                         status of the system."
                ::= { mcmPerfEntry 5 }

        mcmLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this card."
                ::= { mcmPerfEntry 6 }

        mcmAvailTime    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this mcmt1/mcme1 has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { mcmPerfEntry 7 }

        mcmErrFreeSecs  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this mcmt1/mcme1 has not experienced any alarms."
                ::= { mcmPerfEntry 8 }

        mcmBiasCurrent  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Bias current for the optical laser.  This value can
                         be set remotely"
                ::= { mcmPerfEntry 9 }

        mcmModulation   OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The frequency modulation for the optical laser.  This
                         value can be adjusted remotely."
                ::= { mcmPerfEntry 10 }

        mcmApc          OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The APC value.  This value can be set remotely."
                ::= { mcmPerfEntry 11 }

        mcmIwmModulation OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The frequency modulation for the IWM channel.  This
                         value can be adjusted remotely."
                ::= { mcmPerfEntry 12 }

        mcmLaserOnOff   OBJECT-TYPE
                SYNTAX  FlagType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The laser On/Off flag.  This value can be set
                         remotely."
                ::= { mcmPerfEntry 13 }

        mcmTemperature  OBJECT-TYPE
                SYNTAX  Gauge
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The current temperature, or the operating temperature
                         of the optical device."
                ::= { mcmPerfEntry 14 }

        mcmIntensity    OBJECT-TYPE
                SYNTAX  Gauge
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The intensity of the optical light.  This value can
                         be set remotely."
                ::= { mcmPerfEntry 15 }

        mcmSignalStrength OBJECT-TYPE
                SYNTAX  Gauge
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The current signal strength for the optical path."
                ::= { mcmPerfEntry 16 }

        mcmLossOfLight  OBJECT-TYPE
                SYNTAX  Boolean
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "If set to true, no laser light is present.  If set to
                         false, no loss of light has occurred."
                ::= { mcmPerfEntry 17 }

        mcmSignalDetect OBJECT-TYPE
                SYNTAX  Boolean
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "If set to true, signal is detected.  If set to false,
                         no signal is present."
                ::= { mcmPerfEntry 18 }

        mcmPortCurrTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF McmPortCurrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         MCMT1/MCME1 port's current counters."
                ::= { mcmPerf 4 }

        mcmPortCurrEntry OBJECT-TYPE
                SYNTAX  McmPortCurrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { mcmPortCurrCardLocation, mcmPortCurrCardShelf,
                          mcmPortCurrCardSlot,  mcmPortCurrIndex }
                ::= { mcmPortCurrTable 1 }

        McmPortCurrEntry ::=
                SEQUENCE
                {
                        mcmPortCurrCardLocation CardLocation,
                        mcmPortCurrCardShelf    CardShelf,
                        mcmPortCurrCardSlot     INTEGER,
                        mcmPortCurrIndex        INTEGER,
                        mcmPortCurrASs          Counter,
                        mcmPortCurrFrameASs     Counter,
                        mcmPortCurrFEs          Counter,
                        mcmPortCurrCRCErrs      Counter,
                        mcmPortCurrSESs         Counter,
                        mcmPortCurrSEFSs        Counter,
                        mcmPortCurrUASs         Counter,
                        mcmPortCurrLESs         Counter,
                        mcmPortCurrBESs         Counter,
                        mcmPortCurrDMs          Counter,
                        mcmPortCurrLCVs         Counter
                }

        mcmPortCurrCardLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Location of the MCMT1/MCME1 port.  Valid values are: Local in
                         the same chassis, or remote to this chassis"
                ::= { mcmPortCurrEntry 1 }

        mcmPortCurrCardShelf OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 2..3."
                ::= { mcmPortCurrEntry 2 }

        mcmPortCurrCardSlot OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the Module is in."
                ::= { mcmPortCurrEntry 3 }

        mcmPortCurrIndex OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port's index."
                ::= { mcmPortCurrEntry 4 }

        mcmPortCurrASs  OBJECT-TYPE
                SYNTAX  Counter 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's ASs counter less than 15 mins."
                ::= { mcmPortCurrEntry 5 }

        mcmPortCurrFrameASs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's FrameASs counter less than 15 mins."
               ::= { mcmPortCurrEntry 6 }

        mcmPortCurrFEs  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's FEs counter less than 15 mins." 
                ::= { mcmPortCurrEntry 7 }

        mcmPortCurrCRCErrs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's CRC errs counter less than 15 mins."
                ::= { mcmPortCurrEntry 8 }

        mcmPortCurrSESs OBJECT-TYPE
                SYNTAX  Counter 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's SESs counter less than 15 mins."
                ::= { mcmPortCurrEntry 9 }

        mcmPortCurrSEFSs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's SEFSs counter less than 15 mins."
                ::= { mcmPortCurrEntry 10 }

        mcmPortCurrUASs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's UASs counter less than 15 mins." 
                ::= { mcmPortCurrEntry 11 }

        mcmPortCurrLESs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's LESs counter less than 15 mins."
                ::= { mcmPortCurrEntry 12 }

        mcmPortCurrBESs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's BESs counter less than 15 mins."
                ::= { mcmPortCurrEntry 13 }

        mcmPortCurrDMs  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's DMSs counter less than 15 mins."
                ::= { mcmPortCurrEntry 14 }

        mcmPortCurrLCVs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's LCVs counter less than 15 mins."
                ::= { mcmPortCurrEntry 15 }

        -- The elements in the fnPerf subgroup of the current subgroup

        fnNumEvents     OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         Fans in this time slot (15 minutes)."
                ::= { fnPerf 1 }

        fnPerfTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF FnPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each fan module."
                ::= { fnPerf 2 }

        fnPerfEntry     OBJECT-TYPE
                SYNTAX  FnPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { fnPerfID }
                ::= { fnPerfTable 1 }

        FnPerfEntry     ::=
                SEQUENCE
                {
                        fnPerfID                INTEGER,
                        fnPerfState             INTEGER,
                        fnPerfStatus            CardStatus
                }

        fnPerfID        OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The module ID where the fan module is plugged in."
                ::= { fnPerfEntry 1 }

        fnPerfState     OBJECT-TYPE
                SYNTAX  INTEGER { fnEmpty(1), fnOK(2), fnFailed(3), fnDegrade(4) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The state of the fan module."
                ::= { fnPerfEntry 2 }

        fnPerfStatus    OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The status of the fan module.  This status
                         represents the status of the fan module and in general is
                         different from the status of the system."
                ::= { fnPerfEntry 3 }

        -- The elements in the csimPerf subgroup of the current subgroup

        csimNumEvents   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This variable keeps track of the number of events
                         related to ColorSIM. The reason this has been made obsolete
                         is that all colorsim related events would eventually be part
                         of ocm events"
                ::= { csimPerf 1 }
     
        csimCurrentTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF CsimCurrentEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         colorsim card in the most current interval"
                ::= { csimPerf 2 }

        csimCurrentEntry OBJECT-TYPE
                SYNTAX  CsimCurrentEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below."
                INDEX   { csimCurrentLocation, csimCurrentShelf, csimCurrentSlot }
                ::= { csimCurrentTable 1 }

        CsimCurrentEntry ::=
                SEQUENCE
                {
                        csimCurrentLocation     CardLocation,
                        csimCurrentShelf        CardShelf,
                        csimCurrentSlot         INTEGER,
                        csimCurrentEFIs         INTEGER,
                        csimCurrentEIs          INTEGER,
                        csimCurrentSEIs         INTEGER,
                        csimCurrentBERs         DisplayString,
                        csimCurrentUAIs         INTEGER,
                        csimCurrentGIs          INTEGER,
                        csimCurrentDateTime     INTEGER
                }
    
        csimCurrentLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        " Location of the ColorSIM module"
                ::= { csimCurrentEntry 1 }

        csimCurrentShelf OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf of the ColorSIM module"
                ::= { csimCurrentEntry 2 }

        csimCurrentSlot OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The Slot of the ColorSIM module"
                ::= { csimCurrentEntry 3 }

        csimCurrentEFIs OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The counter associated with the number of Error Free
                         Interval Counts in the current update (default: 15
                         minutes) interval."
                ::= { csimCurrentEntry 4 }

        csimCurrentEIs  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The counter associated with the number of Errored
                         Interval Counts in the current update (default: 15
                         minutes) interval."
                ::= { csimCurrentEntry 5 }

        csimCurrentSEIs OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The counter associated with the number of Severly
                         Errored Interval Counts in the current update
                        (default:15 minutes) interval."
                ::= { csimCurrentEntry 6}

        csimCurrentBERs OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The counter associated with the number of Bit Error
                         Rates Counts in the current update (default: 15
                         minutes) interval. The unit will be in the form of
                         x.ye-z."
                ::= { csimCurrentEntry 7 }

        csimCurrentUAIs OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The counter associated with the number of Unavailable
                         Interval Counts in the current update (default: 15
                         minutes) interval."
                ::= { csimCurrentEntry 8 }

        csimCurrentGIs  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of gating intervals over which the data was
                         collected."
                ::= { csimCurrentEntry 9 }

        csimCurrentDateTime OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Time in seconds elasped since 01/01/1970 00:00:00 GMT. Assuming
                         local time is same as GMT"
                ::= { csimCurrentEntry 10 }

        -- The elements in the rpsmPerf subgroup of the current subgroup

        rpsmNumEvents   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         RPSM's in this time slot (15 minutes)."
                ::= { rpsmPerf 1 }
    

        rpsmPerfTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF RpsmPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each rpsm card"
                ::= { rpsmPerf 2 }

        rpsmPerfEntry   OBJECT-TYPE
                SYNTAX  RpsmPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { rpsmPerfLocation, rpsmPerfShelf, rpsmPerfSlot }
                ::= { rpsmPerfTable 1 }

        RpsmPerfEntry    ::=
                SEQUENCE
                {
                        rpsmPerfLocation    CardLocation,
                        rpsmPerfShelf       CardShelf,
                        rpsmPerfSlot        INTEGER,
                        rpsmPerfState       CardState,
                        rpsmPerfStatus      CardStatus,
                        rpsmLinkEastState   INTEGER,
                        rpsmLinkEastStatus  INTEGER,
                        rpsmLinkWestState   INTEGER,
                        rpsmLinkWestStatus  INTEGER,
                        rpsmLastBootTime    DateAndTime,
                        rpsmAvailTime       Counter,
                        rpsmErrFreeSecs     Counter,
                        rpsmWorkingPower    INTEGER,
                        rpsmProtectionPower INTEGER
                }

        rpsmPerfLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card.  Choices are local or
                         remote."
                ::= { rpsmPerfEntry 1 }

        rpsmPerfShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 10"
                ::= { rpsmPerfEntry 2 }

        rpsmPerfSlot    OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { rpsmPerfEntry 3 }

        rpsmPerfState   OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The state of the rpsm card.  The possible states
                         are: online, offline, empty, loopback or diag."
                ::= { rpsmPerfEntry 4 }

        rpsmPerfStatus  OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The status of the rpsm card.  This status represents
                         the status of the rpsm card and in general is
                         different from the status of the system."
                ::= { rpsmPerfEntry 5 }

        rpsmLinkEastState OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            linked(1),
                            notLinked(2),
                            unknown(3)
                        }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The link state of path East, whether light
                         is being detected.  The states are:
                         linked, notLinked."
                ::= { rpsmPerfEntry 6 }

        rpsmLinkEastStatus OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            active(1),
                            standby(2),
                            hibernation(3)
                        }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The status of the card channel.  This status represents
                         the status of the link East of the card and in general
                         is different from the status of the card."
                ::= { rpsmPerfEntry 7 }


        rpsmLinkWestState OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            linked(1),
                            notLinked(2),
                            unknown(3)
                        }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The link state of path West, whether light
                         is being detected.  The states are:
                         linked, notLinked."
                ::= { rpsmPerfEntry 8 }

        rpsmLinkWestStatus OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            active(1),
                            standby(2),
                            hibernation(3)
                        }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The status of the card channel.  This status represents
                         the status of the link West of the card and in general
                         is different from the status of the card."
                ::= { rpsmPerfEntry 9 }


        rpsmLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this card."
                ::= { rpsmPerfEntry 10 }

        rpsmAvailTime   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this rpsm has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { rpsmPerfEntry 11 }

        rpsmErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this rpsm has not experienced any alarms."
                ::= { rpsmPerfEntry 12 }

        rpsmWorkingPower OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Working link power of the RPSM card in dBm."
                ::= { rpsmPerfEntry 13 }

        rpsmProtectionPower OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Protection link power of the RPSM card in dBm."
                ::= { rpsmPerfEntry 14 }

        -- The elements in the rsdmPerf subgroup of the current subgroup

        rsdmNumEvents   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         RSDM's in this time slot (15 minutes)."
                ::= { rsdmPerf 1 }

        rsdmPerfTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF RsdmPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each rsdm card"
                ::= { rsdmPerf 2 }

        rsdmPerfEntry   OBJECT-TYPE
                SYNTAX  RsdmPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { rsdmPerfLocation, rsdmPerfShelf, rsdmPerfSlot }
                ::= { rsdmPerfTable 1 }

        RsdmPerfEntry    ::=
                SEQUENCE
                {
                        rsdmPerfLocation        CardLocation,
                        rsdmPerfShelf           CardShelf,
                        rsdmPerfSlot            INTEGER,
                        rsdmPerfState           CardState,
                        rsdmPerfStatus          CardStatus,
                        rsdmLinkEastState       INTEGER,
                        rsdmLinkEastStatus      INTEGER,
                        rsdmLinkWestState       INTEGER,
                        rsdmLinkWestStatus      INTEGER,
                        rsdmLastBootTime        DateAndTime,
                        rsdmAvailTime           Counter,
                        rsdmErrFreeSecs         Counter,
                        rsdmWorkingPower        INTEGER,
                        rsdmProtectionPower     INTEGER
                }

        rsdmPerfLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card.  Choices are local or remote."
                ::= { rsdmPerfEntry 1 }

        rsdmPerfShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in."
                ::= { rsdmPerfEntry 2 }

        rsdmPerfSlot    OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { rsdmPerfEntry 3 }


        rsdmPerfState   OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The state of the rsdm card.  The states are:
                         online, offline."
                ::= { rsdmPerfEntry 4 }

        rsdmPerfStatus  OBJECT-TYPE
                SYNTAX  CardStatus 
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The status of the rsdm card.  This status represents
                         the status of the rsdm card and in general is
                         different from the status of the system."
                ::= { rsdmPerfEntry 5 }

        rsdmLinkEastState OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            linked(1),
                            notLinked(2),
                            unknown(3)
                        }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The link state of path A, whether light
                         is being detected.  The states are:
                         linked, notLinked."
                ::= { rsdmPerfEntry 6 }

        rsdmLinkEastStatus OBJECT-TYPE
                SYNTAX  INTEGER {
                    active(1),
                    standby(2),
                    hibernation(3)
                }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The status of the card channel.  This status represents
                         the status of the link East of the card and in general is
                         different from the status of the card."
                ::= { rsdmPerfEntry 7 }


        rsdmLinkWestState OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            linked(1),
                            notLinked(2),
                            unknown(3)
                        }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The link state of path West, whether light
                         is being detected.  The states are:
                         linked, notLinked."
                ::= { rsdmPerfEntry 8 }

        rsdmLinkWestStatus   OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            active(1),
                            standby(2),
                            hibernation(3)
                        }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The status of the card channel.  This status represents
                         the status of the link West of the card and in general
                         is different from the status of the card."
                ::= { rsdmPerfEntry 9 }

        rsdmLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this card."
                ::= { rsdmPerfEntry 10 }

        rsdmAvailTime    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this rsdm card has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { rsdmPerfEntry 11 }

        rsdmErrFreeSecs  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this rsdm card has not experienced any alarms."
                ::= { rsdmPerfEntry 12 }

        rsdmWorkingPower OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Working link power of the RSDM card in dBm."
                ::= { rsdmPerfEntry 13 }

        rsdmProtectionPower OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Protection link power of the RSDM card in dBm."
                ::= { rsdmPerfEntry 14 }


        -- The elements in the rtdmPerf subgroup of the current subgroup

        rtdmNumEvents   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         RTDM's in this time slot (15 minutes)."
                ::= { rtdmPerf 1 }
    

        rtdmPerfTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF RtdmPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each rtdm card"
                ::= { rtdmPerf 2 }

        rtdmPerfEntry   OBJECT-TYPE
                SYNTAX  RtdmPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { rtdmPerfLocation, rtdmPerfShelf, rtdmPerfSlot }
                ::= { rtdmPerfTable 1 }

        RtdmPerfEntry    ::=
                SEQUENCE
                {
                        rtdmPerfLocation CardLocation,
                        rtdmPerfShelf    CardShelf,
                        rtdmPerfSlot     INTEGER,
                        rtdmPerfState    CardState,
                        rtdmPerfStatus   CardStatus,
                        rtdmLastBootTime DateAndTime,
                        rtdmAvailTime    Counter,
                        rtdmErrFreeSecs  Counter
                }

        rtdmPerfLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card.  Choices are local or
                         remote."
                ::= { rtdmPerfEntry 1 }

        rtdmPerfShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in."
                ::= { rtdmPerfEntry 2 }

        rtdmPerfSlot    OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { rtdmPerfEntry 3 }

        rtdmPerfState   OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The state of the rtdm card.  The states are:
                         online, offline, empty, loopback or diag."
                ::= { rtdmPerfEntry 4 }

        rtdmPerfStatus  OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The status of the rtdm card.  This status represents
                         the status of the rtdm card and in general is
                         different from the status of the system."
                ::= { rtdmPerfEntry 5 }

        rtdmLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this card."
                ::= { rtdmPerfEntry 6 }

        rtdmAvailTime   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this rtdm has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { rtdmPerfEntry 7 }

        rtdmErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this rtdm has not experienced any alarms."
                ::= { rtdmPerfEntry 8 }

        -- The elements in the osamPerf subgroup of the current subgroup

        osamNumEvents   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of events received for all osam's in
                         the most current 15 minutes slot."
                ::= { osamPerf 1 }

        osamCntrTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF OsamCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entry for the software counters."
                ::= { osamPerf 2 }

        osamCntrEntry   OBJECT-TYPE
                SYNTAX  OsamCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { osamCntrLocation, osamCntrShelf, osamCntrSlot }
                ::= { osamCntrTable 1 }

        OsamCntrEntry   ::=
                SEQUENCE
                {
                        osamCntrLocation            CardLocation,
                        osamCntrShelf               CardShelf,
                        osamCntrSlot                INTEGER,
                        osamCntrKeepAlivePktSent    Counter,
                        osamCntrKeepAlivePktRcvd    Counter,
                        osamCntrKeepAliveBadPktRcvd Counter
                }

        osamCntrLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Location of the module."
                ::= { osamCntrEntry 1 }

        osamCntrShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf number in which the module is plugged in."
                ::= { osamCntrEntry 2 }

        osamCntrSlot    OBJECT-TYPE
                SYNTAX  INTEGER (1..16)
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot number in which the module is plugged in."
                ::= { osamCntrEntry 3 }

        osamCntrKeepAlivePktSent OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The total number of keep alive packets sent."
                ::= { osamCntrEntry 4 }

        osamCntrKeepAlivePktRcvd OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The total number of keep alive packets received."
                ::= { osamCntrEntry 5 }

        osamCntrKeepAliveBadPktRcvd OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The total number of bad keep alive data packets 
                         received."
                ::= { osamCntrEntry 6 }

        osamPerfTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF OsamPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each osam card"
                ::= { osamPerf 3 }

        osamPerfEntry   OBJECT-TYPE
                SYNTAX  OsamPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { osamPerfLocation, osamPerfShelf, osamPerfSlot }
                ::= { osamPerfTable 1 }

        OsamPerfEntry   ::=
                SEQUENCE
                {
                        osamPerfLocation            CardLocation,
                        osamPerfShelf               CardShelf,
                        osamPerfSlot                INTEGER,
                        osamPerfState               CardState,
                        osamPerfStatus              CardStatus,
                        osamPerfLastBootTime        DateAndTime,
                        osamPerfAvailTime           Counter,
                        osamPerfErrFreeSecs         Counter,
                        osamPerfAprStatus           FlagType,
                        osamPerfInputPower          DisplayString,
                        osamPerfBFDPower            DisplayString,
                        osamPerfOutputPower         DisplayString,
                        osamPerfAPRDetector1Power   DisplayString,
                        osamPerfAPRDetector2Power   DisplayString,
                        osamPerfLaserTemperature    INTEGER,
                        osamPerfTecCurrent          INTEGER,
                        osamPerfBiasCurrent         INTEGER,
                        osamPerfAmplifierGain       DisplayString,
                        osamPerfPCBTemperature      INTEGER,
                        osam2PerfPump1BFDPower      INTEGER,
                        osam2PerfPump2BFDPower      INTEGER,
                        osam2PerfPump1IBias         INTEGER,  
                        osam2PerfPump2IBias         INTEGER,
                        osam2PerfPump1ITEC          INTEGER,
                        osam2PerfPump2ITEC          INTEGER,
                        osam2PerfPump1Temp          DisplayString,
                        osam2PerfPump2Temp          DisplayString,    
                        osam2PerfGBInputPower       DisplayString,
                        osam2PerfGBOutputPower      DisplayString,
                        osam2PerfAttenuation        DisplayString         
                }

        osamPerfLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Location of the module."
                ::= { osamPerfEntry 1 }

        osamPerfShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf number in which the module is plugged in."
                ::= { osamPerfEntry 2 }

        osamPerfSlot    OBJECT-TYPE
                SYNTAX  INTEGER (1..16)
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot number in which the module is plugged in."
                ::= { osamPerfEntry 3 }

        osamPerfState   OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The current state of the module."
                ::= { osamPerfEntry 4 }

        osamPerfStatus  OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The current alarm status of the channel."
                ::= { osamPerfEntry 5 }

        osamPerfLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this module."
                ::= { osamPerfEntry 6 }

        osamPerfAvailTime OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in the most current 15 minutes
                         interval that this module has been up and running."
                ::= { osamPerfEntry 7 }

        osamPerfErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in the most current 15 minutes
                         interval that this module has not experienced any
                         alarms."
                ::= { osamPerfEntry 8 }

        osamPerfAprStatus OBJECT-TYPE
                SYNTAX  FlagType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The status of the automatic power reduction mode.
                         Not applicable to OSAM-HP/LP module"
                ::= { osamPerfEntry 9 }

        osamPerfInputPower OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The power at the input in dBm.
                         Not applicable to OSAM-HP/LP 
                         module"
                ::= { osamPerfEntry 10 }

        osamPerfBFDPower OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The back facet diode reading in the pump laser;
                         related to the power output of the pump laser.
                         This values isn't calibrated and doesn't have a
                         unit. Not applicable to OSAM-HP/LP module"
                ::= { osamPerfEntry 11 }

        osamPerfOutputPower OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The power at the output port in dBm."
                ::= { osamPerfEntry 12 }

        osamPerfAPRDetector1Power OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The automatic power reduction detector 1 reading 
                         in dBm. Two readings are provided for redundancy
                         purposes. Not applicable to OSAM-HP/LP module"
                ::= { osamPerfEntry 13 }

        osamPerfAPRDetector2Power OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The automatic power reduction detector 2 reading 
                         in dBm. Two readings are provided for redundancy
                         purposes. Not applicable to OSAM-HP/LP module"
                ::= { osamPerfEntry 14 }

        osamPerfLaserTemperature OBJECT-TYPE
                SYNTAX  INTEGER (15..35)
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The pump laser temperature in degree Celsius.
                         Not applicable to OSAM-HP/LP module"
                ::= { osamPerfEntry 15 }

        osamPerfTecCurrent OBJECT-TYPE
                SYNTAX  INTEGER (0..1500)
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The Thermo-Electric Cooler current in mA.
                         Not applicable to OSAM-HP/LP module"
                ::= { osamPerfEntry 16 }

        osamPerfBiasCurrent OBJECT-TYPE
                SYNTAX  INTEGER (0..255)
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The measured pump laser bias current in mA.
                         Not applicable to OSAM-HP/LP module"
                ::= { osamPerfEntry 17 }

        osamPerfAmplifierGain OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The measured overall amplifier gain in dB."
                ::= { osamPerfEntry 18 }

        osamPerfPCBTemperature OBJECT-TYPE
                SYNTAX  INTEGER (0..75)
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The temperature of the printed circuit board in
                         degree Celsius."
                ::= { osamPerfEntry 19 }

        osam2PerfPump1BFDPower OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The back facet diode reading in pump 1 laser;
                         related to the power output of the pump laser.
                         Unit to represent the value is DAC (Digital to
                         Analog converter)"
                ::= { osamPerfEntry 20 }

        osam2PerfPump2BFDPower OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The back facet diode reading in pump 2 laser;
                         related to the power output of the pump laser.
                         Unit to represent the value is DAC (Digital to
                         Analog converter).
                         Applicable only for OSAM-HP module"
                ::= { osamPerfEntry 21 }

        osam2PerfPump1IBias OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Indicates the bias current of Pump 1 in mA. 
                         The range of values of bias current range from 40 mA - 
                         barely turning on, to MaxIbias - maximum operating current 
                         recommended by the manufacturer.  
                         Pump IBias is used internally to set off alarms and to indicate the 
                         health of the module."
                ::= { osamPerfEntry 22 }

        osam2PerfPump2IBias OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Indicates the bias current of Pump 2 in mA. 
                         The range of values of bias current range from 40 mA - 
                         barely turning on, to MaxIbias - maximum operating current 
                         recommended by the manufacturer.  
                         Pump IBias is used internally to set off alarms and to indicate the 
                         health of the module.
                         Applicable only for OSAM-HP module"
                ::= { osamPerfEntry 23 }

        osam2PerfPump1ITEC OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Indicates the current level in mA of Thermal Electric Cooler (TEC)
                         used for cooling laser pump 1. "
                ::= { osamPerfEntry 24 }

        osam2PerfPump2ITEC OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Indicates the current level in mA of Thermal Electric Cooler (TEC)
                         used for cooling laser pump 2. 
                         Applicable only for OSAM-HP"
                ::= { osamPerfEntry 25 }

        osam2PerfPump1Temp OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Laser pump (#1) temperature in degree celcius"
                ::= { osamPerfEntry 26 }

        osam2PerfPump2Temp OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Laser pump (#2) temperature in degree celcius
                         Applicable only for OSAM-HP module"
                ::= { osamPerfEntry 27 }

        osam2PerfGBInputPower OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Gain block input power in dBm."
                ::= { osamPerfEntry 28 }

        osam2PerfGBOutputPower OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Gain block output power in dBm with attenuation
                         set to zero."
                ::= { osamPerfEntry 29 }

        osam2PerfAttenuation OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Indicates optical attenuation in dB imposed by
                         variable optical attenuator(VOA)"
                ::= { osamPerfEntry 30 }

        -- The elements in the rsmPerf subgroup of the current subgroup

        rsmNumEvents    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         RSM's in this time slot (15 minutes)."
                ::= { rsmPerf 1 }
    

        rsmPerfTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF RsmPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each rsm card"
                ::= { rsmPerf 2 }

        rsmPerfEntry    OBJECT-TYPE
                SYNTAX  RsmPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { rsmPerfLocation, rsmPerfShelf, rsmPerfSlot }
                ::= { rsmPerfTable 1 }

        RsmPerfEntry    ::=
                SEQUENCE
                {
                        rsmPerfLocation         CardLocation,
                        rsmPerfShelf            CardShelf,
                        rsmPerfSlot             CardSlot,
                        rsmPerfState            CardState,
                        rsmPerfStatus           CardStatus,
                        rsmLinkAState           INTEGER,
                        rsmLinkAStatus          INTEGER,
                        rsmLinkBState           INTEGER,
                        rsmLinkBStatus          INTEGER,
                        rsmLastBootTime         DateAndTime,
                        rsmAvailTime            Counter,
                        rsmErrFreeSecs          Counter,
                        rsmWorkingPower         INTEGER,
                        rsmProtectionPower      INTEGER
                }

        rsmPerfLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card."
                ::= { rsmPerfEntry 1 }

        rsmPerfShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in."
                ::= { rsmPerfEntry 2 }

        rsmPerfSlot     OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { rsmPerfEntry 3 }

        rsmPerfState    OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The state of the rsm card.  The possible states
                         are: online, offline, empty, loopback or diag."
                ::= { rsmPerfEntry 4 }

        rsmPerfStatus   OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The status of the rsm card.  This status represents
                         the status of the rsm card and in general is
                         different from the status of the system."
                ::= { rsmPerfEntry 5 }

        rsmLinkAState   OBJECT-TYPE
                SYNTAX  INTEGER { linked(1), notLinked(2), unknown(3) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The link state of path A (East), whether light
                         is being detected.  The states are:
                         linked, notLinked."
                ::= { rsmPerfEntry 6 }

        rsmLinkAStatus  OBJECT-TYPE
                SYNTAX  INTEGER { active(1), standby(2), na(3) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The status of the card channel.  This status represents
                         the status of the link A (East) of the card and in general
                         is different from the status of the card."
                ::= { rsmPerfEntry 7 }


        rsmLinkBState   OBJECT-TYPE
                SYNTAX  INTEGER  { linked(1), notLinked(2), unknown(3) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The link state of path B (West), whether light
                         is being detected.  The states are:
                         linked, notLinked."
                ::= { rsmPerfEntry 8 }

        rsmLinkBStatus  OBJECT-TYPE
                SYNTAX  INTEGER { active(1), standby(2), na(3) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The status of the card channel.  This status represents
                         the status of the link B (West) of the card and in general
                         is different from the status of the card."
                ::= { rsmPerfEntry 9 }

        rsmLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this card."
                ::= { rsmPerfEntry 10 }

        rsmAvailTime    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this rsm has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { rsmPerfEntry 11 }

        rsmErrFreeSecs  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this rsm has not experienced any alarms."
                ::= { rsmPerfEntry 12 }

        rsmWorkingPower OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Working link power of the RSM card in dBm."
                ::= { rsmPerfEntry 13 }

        rsmProtectionPower OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Protection link power of the RSM card in dBm."
                ::= { rsmPerfEntry 14 }

        -- The elements in the upsmPerf subgroup of the current subgroup

        upsmNumEvents   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         UPSM's in this time slot (15 minutes)."
                ::= { upsmPerf 1 }
    

        upsmPerfTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF UpsmPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each upsm card"
                ::= { upsmPerf 2 }

        upsmPerfEntry   OBJECT-TYPE
                SYNTAX  UpsmPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { upsmPerfLocation, upsmPerfShelf, upsmPerfSlot }
                ::= { upsmPerfTable 1 }

        UpsmPerfEntry   ::=
                SEQUENCE
                {
                        upsmPerfLocation        CardLocation,
                        upsmPerfShelf           CardShelf,
                        upsmPerfSlot            CardSlot,
                        upsmPerfState           CardState,
                        upsmPerfStatus          CardStatus,
                        upsmLinkAState          INTEGER,
                        upsmLinkAStatus         INTEGER,
                        upsmLinkBState          INTEGER,
                        upsmLinkBStatus         INTEGER,
                        upsmLastBootTime        DateAndTime,
                        upsmAvailTime           Counter,
                        upsmErrFreeSecs         Counter,
                        upsmWorkingPower        INTEGER,
                        upsmProtectionPower     INTEGER
                }

        upsmPerfLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card."
                ::= { upsmPerfEntry 1 }

        upsmPerfShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in."
                ::= { upsmPerfEntry 2 }

        upsmPerfSlot    OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { upsmPerfEntry 3 }

        upsmPerfState   OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The state of the upsm card.  The possible states
                         are: online, offline, empty, loopback or diag."
                ::= { upsmPerfEntry 4 }

        upsmPerfStatus  OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The status of the upsm card.  This status represents
                         the status of the upsm card and in general is
                         different from the status of the system."
                ::= { upsmPerfEntry 5 }

        upsmLinkAState  OBJECT-TYPE
                SYNTAX  INTEGER { linked(1), notLinked(2), unknown(3) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The link state of path A (East), whether light
                         is being detected.  The states are:
                         linked, notLinked."
                ::= { upsmPerfEntry 6 }

        upsmLinkAStatus   OBJECT-TYPE
                SYNTAX  INTEGER { active(1), standby(2), hibernation(3) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The status of the card channel.  This status represents
                         the status of the link A (East) of the card and in general
                         is different from the status of the card."
                ::= { upsmPerfEntry 7 }

        upsmLinkBState  OBJECT-TYPE
                SYNTAX  INTEGER { linked(1), notLinked(2), unknown(3) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The link state of path B (West), whether light
                         is being detected.  The states are:
                         linked, notLinked."
                ::= { upsmPerfEntry 8 }

        upsmLinkBStatus OBJECT-TYPE
                SYNTAX  INTEGER { active(1), standby(2), hibernation(3) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The status of the card channel.  This status represents
                         the status of the link B (West) of the card and in general
                         is different from the status of the card."
                ::= { upsmPerfEntry 9 }

        upsmLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this card."
                ::= { upsmPerfEntry 10 }

        upsmAvailTime   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this upsm has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { upsmPerfEntry 11 }

        upsmErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this upsm has not experienced any alarms."
                ::= { upsmPerfEntry 12 }

        upsmWorkingPower OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Working link power of the UPSM card in dBm."
                ::= { upsmPerfEntry 13 }

        upsmProtectionPower OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Protection link power of the UPSM card in dBm."
                ::= { upsmPerfEntry 14 }

        -- The elements in the mcmescPerf subgroup of the current subgroup

        mcmescNumEvents OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of events received for all mcmesc's in
                         this time slot (15 minutes)."
                ::= { mcmescPerf 1 }

        mcmescCntrTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF McmescCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entry for the software counters."
                ::= { mcmescPerf 2 }

        mcmescCntrEntry OBJECT-TYPE
                SYNTAX  McmescCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { mcmescCntrLocation, mcmescCntrShelf, mcmescCntrSlot, mcmescCntrType }
                ::= { mcmescCntrTable 1 }

        McmescCntrEntry ::=
                SEQUENCE
                {
                        mcmescCntrLocation      CardLocation,
                        mcmescCntrShelf         CardShelf,
                        mcmescCntrSlot          INTEGER,
                        mcmescCntrType          INTEGER,
                        mcmescCounterFlag       FlagType,
                        mcmescTotPktSent        Counter,
                        mcmescTotPktRcvd        Counter,
                        mcmescBadPktRcvd        Counter,
                        mcmescTotBadTrans       Counter,
                        mcmescBytesSent         Counter,
                        mcmescBytesRcvd         Counter,
                        mcmescMsgsDlvrd         Counter,
                        mcmescClearCntrs        ResetType
                }

        mcmescCntrLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the mcmesc card.  The values are: Local
                         or Remote.  The system automatically determines the
                         right value for this entry based on the known
                         mcmesc cards."
                ::= { mcmescCntrEntry 1 }

        mcmescCntrShelf OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 3.
                         The system automatically determines the right value
                         for this entry based on the known (available) mcmesc
                         cards."
                ::= { mcmescCntrEntry 2 }

        mcmescCntrSlot  OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  Valid
                         values are: 1 to 21.  The system automatically
                         determines the right value for this entry based
                         on the known (available) mcmesc cards."
                ::= { mcmescCntrEntry 3 }

        mcmescCntrType  OBJECT-TYPE
                SYNTAX  INTEGER { spi(1), iwm(2) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The type of the software counter data in this row.
                         The data is collected for the SPI data channels."
                ::= { mcmescCntrEntry 4 }

        mcmescCounterFlag OBJECT-TYPE
                SYNTAX  FlagType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Turns software counters On or Off for this mcmesc."
                ::= { mcmescCntrEntry 5 }

        mcmescTotPktSent OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets sent over the given data
                         channel."
                ::= { mcmescCntrEntry 6 }

        mcmescTotPktRcvd OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets received over the given
                         data channel."
                ::= { mcmescCntrEntry 7 }

        mcmescBadPktRcvd OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data packets received over the given
                         data channel."
                ::= { mcmescCntrEntry 8 }

        mcmescTotBadTrans OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data transmissions over the given
                         data channel."
                ::= { mcmescCntrEntry 9 }

        mcmescBytesSent OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of bytes sent over the given
                         data channel."
                ::= { mcmescCntrEntry 10 }

        mcmescBytesRcvd OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of data bytes received over the given
                         data channel."
                ::= { mcmescCntrEntry 11 }

        mcmescMsgsDlvrd OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of complete messages delivered over the
                         given data channel."
                ::= { mcmescCntrEntry 12 }

        mcmescClearCntrs OBJECT-TYPE
                SYNTAX  ResetType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "If the value is reset, all software counters
                         are reset to zero.  A get on this will always return other"
                ::= { mcmescCntrEntry 13 }

        mcmescPerfTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF McmescPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each mcmesc card"
                ::= { mcmescPerf 3 }

        mcmescPerfEntry OBJECT-TYPE
                SYNTAX  McmescPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { mcmescPerfLocation, mcmescPerfShelf, mcmescPerfSlot }
                ::= { mcmescPerfTable 1 }

        McmescPerfEntry ::=
                SEQUENCE
                {
                        mcmescPerfLocation      CardLocation,
                        mcmescPerfShelf         CardShelf,
                        mcmescPerfSlot          INTEGER,
                        mcmescPerfState         CardState,
                        mcmescPerfStatus        CardStatus,
                        mcmescLastBootTime      DateAndTime,
                        mcmescAvailTime         Counter
                }

        mcmescPerfLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card.  Valid choices are Local
                         or Remote.  The system automatically selects this
                         value based on the known (available) mcmesc cards."
                ::= { mcmescPerfEntry 1 }

        mcmescPerfShelf OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 3"
                ::= { mcmescPerfEntry 2 }

        mcmescPerfSlot  OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  Valid
                         values are: 1 to 21"
                ::= { mcmescPerfEntry 3 }

        mcmescPerfState OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The state of the mcmesc card.  The states' are:
                         online, offline, empty, loopback or diagnostics."
                ::= {mcmescPerfEntry 4 }

        mcmescPerfStatus OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The status of the channel card.  This
                         status represents the status of the communication
                         processor and in general is different from the
                         status of the system."
                ::= { mcmescPerfEntry 5 }

        mcmescLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this card."
                ::= { mcmescPerfEntry 6 }

        mcmescAvailTime OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this mcmesc has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { mcmescPerfEntry 7 }


        mcmescPortCurrTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF McmescPortCurrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         mcmesc cpe port's current counters."
                ::= { mcmescPerf 4 }

        mcmescPortCurrEntry OBJECT-TYPE
                SYNTAX  McmescPortCurrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { mcmescPortCurrCardLocation, mcmescPortCurrCardShelf,
                          mcmescPortCurrCardSlot,  mcmescPortCurrPort }
                ::= { mcmescPortCurrTable 1 }

        McmescPortCurrEntry ::=
                SEQUENCE
                {
                        mcmescPortCurrCardLocation  CardLocation,
                        mcmescPortCurrCardShelf     CardShelf,
                        mcmescPortCurrCardSlot      INTEGER,
                        mcmescPortCurrPort          INTEGER,
                        mcmescPortCurrRxSig         DisplayString,
                        mcmescPortCurrDuration      DisplayString,
                        mcmescPortCurrEns           DisplayString,
                        mcmescPortCurrLoss          DisplayString,
                        mcmescPortCurrCrcErr        DisplayString,
                        mcmescPortCurrOobErr        DisplayString,
                        mcmescPortCurrRdpErr        DisplayString,
                        mcmescPortCurrBer           DisplayString  
                }

        mcmescPortCurrCardLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Location of the MCMESC CPE port.  Valid values are: Local in
                         the same chassis, or remote to this chassis"
                ::= { mcmescPortCurrEntry 1 }

        mcmescPortCurrCardShelf OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 2..3."
                ::= { mcmescPortCurrEntry 2 }

        mcmescPortCurrCardSlot OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the Module is in."
                ::= { mcmescPortCurrEntry 3 }

        mcmescPortCurrPort OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CPE port's index."
                ::= { mcmescPortCurrEntry 4 }

        mcmescPortCurrRxSig OBJECT-TYPE
               SYNTAX  DisplayString (SIZE (0..10))
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CPE port's receive signal power." 
                ::= { mcmescPortCurrEntry 5 }

        mcmescPortCurrDuration OBJECT-TYPE
                SYNTAX  DisplayString 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "mcmesc CPE port's current ongoing interval duration."
                ::= { mcmescPortCurrEntry 6 }

       mcmescPortCurrEns OBJECT-TYPE
               SYNTAX  DisplayString
               ACCESS  read-only
               STATUS  mandatory
               DESCRIPTION
                       "mcmesc CPE port's enabled seconds during current ongoing 
                        interval."
              ::= { mcmescPortCurrEntry 7 }

        mcmescPortCurrLoss OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "mcmesc CPE port's loss of signal seconds during current 
                         ongoing interval." 
                ::= { mcmescPortCurrEntry 8 }

        mcmescPortCurrCrcErr OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "mcmesc CPE port's CRC error counter during current 
                         ongoing interval."
                ::= { mcmescPortCurrEntry 9 }

        mcmescPortCurrOobErr OBJECT-TYPE
                SYNTAX  DisplayString 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "mcmesc CPE port's Out-Of_Band error counter during current 
                         ongoing interval." 
                ::= { mcmescPortCurrEntry 10 }

        mcmescPortCurrRdpErr OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "mcmesc CPE port's Running Disparity error counter during current 
                         ongoing interval." 
                ::= { mcmescPortCurrEntry 11 }

        mcmescPortCurrBer OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "mcmesc CPE port's BER, in the form of x.yE-z." 
                ::= { mcmescPortCurrEntry 12 }

        mcmescLinkCurrTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF McmescLinkCurrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         mcmesc cpe port's current counters."
                ::= { mcmescPerf 5 }

        mcmescLinkCurrEntry OBJECT-TYPE
                SYNTAX  McmescLinkCurrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { mcmescLinkCurrCardLocation, mcmescLinkCurrCardShelf,
                          mcmescLinkCurrCardSlot }
                ::= { mcmescLinkCurrTable 1 }

        McmescLinkCurrEntry ::=
                SEQUENCE
                {
                        mcmescLinkCurrCardLocation  CardLocation,
                        mcmescLinkCurrCardShelf     CardShelf,
                        mcmescLinkCurrCardSlot      INTEGER,
                        mcmescLinkCurrRxSig         DisplayString,
                        mcmescLinkCurrDuration      DisplayString,
                        mcmescLinkCurrTsos          DisplayString,
                        mcmescLinkCurrLoss          DisplayString,
                        mcmescLinkCurrCrcErr        DisplayString,
                        mcmescLinkCurrOobErr        DisplayString,
                        mcmescLinkCurrRdpErr        DisplayString,
                        mcmescLinkCurrBer           DisplayString  
                }

        mcmescLinkCurrCardLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Location of the MCMESC CPE port.  Valid values are: Local in
                         the same chassis, or remote to this chassis"
                ::= { mcmescLinkCurrEntry 1 }

        mcmescLinkCurrCardShelf OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 2..3."
                ::= { mcmescLinkCurrEntry 2 }

        mcmescLinkCurrCardSlot OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the Module is in."
                ::= { mcmescLinkCurrEntry 3 }

       mcmescLinkCurrRxSig OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..10))
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Link port's receive signal power." 
                ::= { mcmescLinkCurrEntry 4 }

        mcmescLinkCurrDuration OBJECT-TYPE
                SYNTAX  DisplayString 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "mcmesc LINK port's current ongoing interval duration."
                ::= { mcmescLinkCurrEntry 5 }

       mcmescLinkCurrTsos OBJECT-TYPE
               SYNTAX  DisplayString
               ACCESS  read-only
               STATUS  mandatory
               DESCRIPTION
                       "mcmesc LINK port's test-sequence on seconds during current ongoing 
                        interval."
              ::= { mcmescLinkCurrEntry 6 }

        mcmescLinkCurrLoss OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "mcmesc LINK port's loss of signal seconds during current 
                         ongoing interval." 
                ::= { mcmescLinkCurrEntry 7 }

        mcmescLinkCurrCrcErr OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "mcmesc LINK port's CRC error counter during current 
                         ongoing interval."
                ::= { mcmescLinkCurrEntry 8 }

        mcmescLinkCurrOobErr OBJECT-TYPE
                SYNTAX  DisplayString 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "mcmesc LINK port's Out-Of_Band error counter during current 
                         ongoing interval." 
                ::= { mcmescLinkCurrEntry 9 }

        mcmescLinkCurrRdpErr OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "mcmesc LINK port's Running Disparity error counter during current 
                         ongoing interval." 
                ::= { mcmescLinkCurrEntry 10 }

        mcmescLinkCurrBer OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "mcmesc LINK port's BER, in the form of x.yE-z." 
                ::= { mcmescLinkCurrEntry 11 }

        -- The elements in the routingPerf subgroup of the current subgroup

        imnRoutingPerfTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF ImnRoutingPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each route"
                ::= { routingPerf 1 }

        imnRoutingPerfEntry OBJECT-TYPE
                SYNTAX  ImnRoutingPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { imnRoutePerfIpDest}
                ::= { imnRoutingPerfTable 1 }

        ImnRoutingPerfEntry ::=
                SEQUENCE
                {
                        imnRoutePerfIpDest      IpAddress,
                        imnRoutePerfStatus      INTEGER
                }


        imnRoutePerfIpDest OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Destination IP address. Not supported for
                         remote TMM masters."
                ::= { imnRoutingPerfEntry 1}

        imnRoutePerfStatus OBJECT-TYPE
                SYNTAX  INTEGER { dead(1), comatose(2), active(3) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Is the route active, comatose or dead"
                ::= { imnRoutingPerfEntry 2}

        -- The elements in the muxPerf subgroup of the current subgroup

        tapNumEvents    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         TAP modules in this time slot (15 minutes)."
                ::= { tapPerf 1 }
    

        tapPerfTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF TapPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each TAP module."
                ::= { tapPerf 2 }

        tapPerfEntry    OBJECT-TYPE
                SYNTAX  TapPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { tapPerfLocation, tapPerfShelf, tapPerfSlot }
                ::= { tapPerfTable 1 }

        TapPerfEntry    ::=
                SEQUENCE
                {
                        tapPerfLocation         CardLocation,
                        tapPerfShelf            CardShelf,
                        tapPerfSlot             INTEGER,
                        tapType                 INTEGER,
                        tapPerfState            CardState,
                        tapPerfStatus           CardStatus,
                        tapLastBootTime         DateAndTime,
                        tapAvailTime            Counter,
                        tapErrFreeSecs          Counter
                }

        tapPerfLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the module.  Choices are local or remote."
                ::= { tapPerfEntry 1 }

        tapPerfShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the module is in."
                ::= { tapPerfEntry 2 }

        tapPerfSlot     OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the module is in."
                ::= { tapPerfEntry 3 }

        tapType         OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module type."
                ::= { tapPerfEntry 4 }

        tapPerfState    OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The state of the TAP module.  The states are:
                         online, offline, empty, loopback or diag."
                ::= { tapPerfEntry 5 }

        tapPerfStatus   OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The status of the TAP module.  This status represents
                         the status of the TAP module and in general is
                         different from the status of the system."
                ::= { tapPerfEntry 6 }

        tapLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this module."
                ::= { tapPerfEntry 7 }

        tapAvailTime    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this module has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { tapPerfEntry 8 }

        tapErrFreeSecs  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this module has not experienced any alarms."
                ::= { tapPerfEntry 9 }

        -- The elements in the voadmPerf subgroup of the current subgroup

        voadmNumEvents    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         VOADM modules in this time slot (15 minutes)."
                ::= { voadmPerf 1 }
    

        voadmPerfTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF VoadmPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each VOADM module."
                ::= { voadmPerf 2 }

        voadmPerfEntry    OBJECT-TYPE
                SYNTAX  VoadmPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { voadmPerfLocation, voadmPerfShelf, voadmPerfSlot }
                ::= { voadmPerfTable 1 }

        VoadmPerfEntry    ::=
                SEQUENCE
                {
                        voadmPerfLocation         CardLocation,
                        voadmPerfShelf            CardShelf,
                        voadmPerfSlot             INTEGER,
                        voadmType                 INTEGER,
                        voadmPerfState            CardState,
                        voadmPerfStatus           CardStatus,
                        voadmLastBootTime         DateAndTime,
                        voadmAvailTime            Counter,
                        voadmErrFreeSecs          Counter
                }

        voadmPerfLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the module.  Choices are local or remote."
                ::= { voadmPerfEntry 1 }

        voadmPerfShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the module is in."
                ::= { voadmPerfEntry 2 }

        voadmPerfSlot     OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the module is in."
                ::= { voadmPerfEntry 3 }

        voadmType         OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module type."
                ::= { voadmPerfEntry 4 }

        voadmPerfState    OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The state of the VOADM module.  The states are:
                         online, offline, empty, loopback or diag."
                ::= { voadmPerfEntry 5 }

        voadmPerfStatus   OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The status of the VOADM module.  This status represents
                         the status of the VOADM module and in general is
                         different from the status of the system."
                ::= { voadmPerfEntry 6 }

        voadmLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this module."
                ::= { voadmPerfEntry 7 }

        voadmAvailTime    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this module has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { voadmPerfEntry 8 }

        voadmErrFreeSecs  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this module has not experienced any alarms."
                ::= { voadmPerfEntry 9 }

        -- The elements in the dmmPerf subgroup of the current subgroup

        dmmNumEvents    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         DMM modules in this time slot (15 minutes)."
                ::= { dmmPerf 1 }
    

        dmmPerfTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF DmmPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each DMM module."
                ::= { dmmPerf 2 }

        dmmPerfEntry    OBJECT-TYPE
                SYNTAX  DmmPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { dmmPerfLocation, dmmPerfShelf, dmmPerfSlot }
                ::= { dmmPerfTable 1 }

        DmmPerfEntry    ::=
                SEQUENCE
                {
                        dmmPerfLocation         CardLocation,
                        dmmPerfShelf            CardShelf,
                        dmmPerfSlot             INTEGER,
                        dmmPerfState            CardState,
                        dmmPerfStatus           CardStatus,
                        dmmLastBootTime         DateAndTime,
                        dmmAvailTime            Counter,
                        dmmErrFreeSecs          Counter
                }

        dmmPerfLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the module.  Choices are local or remote."
                ::= { dmmPerfEntry 1 }

        dmmPerfShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the module is in."
                ::= { dmmPerfEntry 2 }

        dmmPerfSlot     OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the module is in."
                ::= { dmmPerfEntry 3 }

        dmmPerfState    OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The state of the DMM module.  The states are:
                         online, offline, empty, loopback or diag."
                ::= { dmmPerfEntry 4 }

        dmmPerfStatus   OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The status of the DMM module.  This status represents
                         the status of the DMM module and in general is
                         different from the status of the system."
                ::= { dmmPerfEntry 5 }

        dmmLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this module."
                ::= { dmmPerfEntry 6 }

        dmmAvailTime    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this module has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { dmmPerfEntry 7 }

        dmmErrFreeSecs  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this module has not experienced any alarms."
                ::= { dmmPerfEntry 8 }

        dmmCntrTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF DmmCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entry for the software counters."
                ::= { dmmPerf 3 }

        dmmCntrEntry     OBJECT-TYPE
                SYNTAX  DmmCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { dmmCntrLocation, dmmCntrShelf, dmmCntrSlot, dmmCntrType }
                ::= { dmmCntrTable 1 }

        DmmCntrEntry     ::=
                SEQUENCE
                {
                        dmmCntrLocation          CardLocation,
                        dmmCntrShelf             CardShelf,
                        dmmCntrSlot              INTEGER,
                        dmmCntrType              INTEGER,
                        dmmTotPktSent            Counter,
                        dmmTotPktRcvd            Counter,
                        dmmTotBadTrans           Counter,
                        dmmBadPktRcvd            Counter,
                        dmmBytesSent             Counter,
                        dmmBytesRcvd             Counter,
                        dmmMsgsDlvrd             Counter,
                        dmmClearCntrs            ResetType
                }

        dmmCntrLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the DMM card.  The values are: Local
                         or Remote.  The system automatically determines the
                         right value for this entry based on the known
                         DMM cards."
                ::= { dmmCntrEntry 1 }

        dmmCntrShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2.
                         The system automatically determines the right value
                         for this entry based on the known (available) DMM
                         cards."
                ::= { dmmCntrEntry 2 }

        dmmCntrSlot     OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  Valid
                         values are: 1 to 17.  The system automatically
                         determines the right value for this entry based
                         on the known (available) DMM cards."
                ::= { dmmCntrEntry 3 }

        dmmCntrType     OBJECT-TYPE
                SYNTAX  INTEGER { spi(1), ibm(2), hdlc(3) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The type of the software counter data in this row."
                ::= { dmmCntrEntry 4 }

        dmmTotPktSent   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets sent over the given data
                         channel."
                ::= { dmmCntrEntry 5 }

        dmmTotPktRcvd   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets received over the given
                         data channel."
                ::= { dmmCntrEntry 6 }

        dmmTotBadTrans  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data transmissions over the given
                         data channel."
                ::= { dmmCntrEntry 7 }

        dmmBadPktRcvd   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data packets received over the given
                         data channel."
                ::= { dmmCntrEntry 8 }

        dmmBytesSent    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of bytes sent over the given
                         data channel."
                ::= { dmmCntrEntry 9 }

        dmmBytesRcvd    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of data bytes received over the given
                         data channel."
                ::= { dmmCntrEntry 10 }

        dmmMsgsDlvrd    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of complete messages delivered over the
                         given data channel."
                ::= { dmmCntrEntry 11 }

        dmmClearCntrs   OBJECT-TYPE
                SYNTAX  ResetType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "If the value is reset, all software counters for this
                         15 minute interval are reset to zero.  A get on this
                         will always return other"
                ::= { dmmCntrEntry 12 }

        dmmPmTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF DmmPmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entry for the software counters."
                ::= { dmmPerf 4 }

        dmmPmEntry      OBJECT-TYPE
                SYNTAX  DmmPmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { dmmPmLocation, dmmPmShelf, dmmPmSlot, dmmPmType }
                ::= { dmmPmTable 1 }

        DmmPmEntry     ::=
                SEQUENCE
                {
                        dmmPmLocation           CardLocation,
                        dmmPmShelf              CardShelf,
                        dmmPmSlot               INTEGER,
                        dmmPmType               INTEGER,
                        dmmPmErrors             Counter,
                        dmmPmErredSecs          Counter,
                        dmmStartTime            DateAndTime,
                        dmmClearPmCntrs         ResetType,
                        dmmPmRxPower            DisplayString,
                        dmmPmTxPower            DisplayString
                }

        dmmPmLocation   OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the DMM card.  The values are: Local
                         or Remote.  The system automatically determines the
                         right value for this entry based on the known
                         DMM cards."
                ::= { dmmPmEntry 1 }

        dmmPmShelf      OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2.
                         The system automatically determines the right value
                         for this entry based on the known (available) DMM
                         cards."
                ::= { dmmPmEntry 2 }

        dmmPmSlot       OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  Valid
                         values are: 1 to 17.  The system automatically
                         determines the right value for this entry based
                         on the known (available) DMM cards."
                ::= { dmmPmEntry 3 }

        dmmPmType       OBJECT-TYPE
                SYNTAX  INTEGER { link(1), port1(2), port2(3) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The type of the software counter data in this row."
                ::= { dmmPmEntry 4 }

        dmmPmErrors     OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of packets errors since port last came online."
                ::= { dmmPmEntry 5 }

        dmmPmErredSecs  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of erred seconds since port last came online."
                ::= { dmmPmEntry 6 }

        dmmStartTime    OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date/time the port came last online."
                ::= { dmmPmEntry 7 }

        dmmClearPmCntrs   OBJECT-TYPE
                SYNTAX  ResetType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "If the value is reset, all PM counters for this
                         port are reset to zero.  A get on this will always
                         return other"
                ::= { dmmPmEntry 8 }

        dmmPmRxPower OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port receive power."
                ::= { dmmPmEntry 9 }

        dmmPmTxPower OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port receive power."
                ::= { dmmPmEntry 10 }


        -- The elements in the ocm10gfPerf subgroup of the current subgroup

        ocm10gfNumEvents    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         OCM10GF modules in this time slot (15 minutes)."
                ::= { ocm10gfPerf 1 }
    

        ocm10gfPerfTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF Ocm10gfPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each OCM10GF module."
                ::= { ocm10gfPerf 2 }

        ocm10gfPerfEntry    OBJECT-TYPE
                SYNTAX  Ocm10gfPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { ocm10gfPerfLocation, ocm10gfPerfShelf, ocm10gfPerfSlot }
                ::= { ocm10gfPerfTable 1 }

        Ocm10gfPerfEntry    ::=
                SEQUENCE
                {
                        ocm10gfPerfLocation         CardLocation,
                        ocm10gfPerfShelf            CardShelf,
                        ocm10gfPerfSlot             INTEGER,
                        ocm10gfPerfState            CardState,
                        ocm10gfPerfStatus           CardStatus,
                        ocm10gfLastBootTime         DateAndTime,
                        ocm10gfAvailTime            Counter,
                        ocm10gfErrFreeSecs          Counter
                }

        ocm10gfPerfLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the module.  Choices are local or remote."
                ::= { ocm10gfPerfEntry 1 }

        ocm10gfPerfShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the module is in."
                ::= { ocm10gfPerfEntry 2 }

        ocm10gfPerfSlot     OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the module is in."
                ::= { ocm10gfPerfEntry 3 }

        ocm10gfPerfState    OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The state of the OCM10GF module.  The states are:
                         online, offline, empty, loopback or diag."
                ::= { ocm10gfPerfEntry 4 }

        ocm10gfPerfStatus   OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The status of the OCM10GF module.  This status represents
                         the status of the OCM10GF module and in general is
                         different from the status of the system."
                ::= { ocm10gfPerfEntry 5 }

        ocm10gfLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this module."
                ::= { ocm10gfPerfEntry 6 }

        ocm10gfAvailTime    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this module has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { ocm10gfPerfEntry 7 }

        ocm10gfErrFreeSecs  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this module has not experienced any alarms."
                ::= { ocm10gfPerfEntry 8 }

        ocm10gfCntrTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF Ocm10gfCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entry for the software counters."
                ::= { ocm10gfPerf 3 }

        ocm10gfCntrEntry     OBJECT-TYPE
                SYNTAX  Ocm10gfCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { ocm10gfCntrLocation, ocm10gfCntrShelf, ocm10gfCntrSlot, ocm10gfCntrType }
                ::= { ocm10gfCntrTable 1 }

        Ocm10gfCntrEntry     ::=
                SEQUENCE
                {
                        ocm10gfCntrLocation          CardLocation,
                        ocm10gfCntrShelf             CardShelf,
                        ocm10gfCntrSlot              INTEGER,
                        ocm10gfCntrType              INTEGER,
                        ocm10gfTotPktSent            Counter,
                        ocm10gfTotPktRcvd            Counter,
                        ocm10gfTotBadTrans           Counter,
                        ocm10gfBadPktRcvd            Counter,
                        ocm10gfBytesSent             Counter,
                        ocm10gfBytesRcvd             Counter,
                        ocm10gfMsgsDlvrd             Counter,
                        ocm10gfClearCntrs            ResetType
                }

        ocm10gfCntrLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the OCM10GF card.  The values are: Local
                         or Remote.  The system automatically determines the
                         right value for this entry based on the known
                         OCM10GF cards."
                ::= { ocm10gfCntrEntry 1 }

        ocm10gfCntrShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2.
                         The system automatically determines the right value
                         for this entry based on the known (available) OCM10GF
                         cards."
                ::= { ocm10gfCntrEntry 2 }

        ocm10gfCntrSlot     OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  Valid
                         values are: 1 to 17.  The system automatically
                         determines the right value for this entry based
                         on the known (available) OCM10GF cards."
                ::= { ocm10gfCntrEntry 3 }

        ocm10gfCntrType     OBJECT-TYPE
                SYNTAX  INTEGER { spi(1), ibm(2), hdlc(3) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The type of the software counter data in this row."
                ::= { ocm10gfCntrEntry 4 }

        ocm10gfTotPktSent   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets sent over the given data
                         channel."
                ::= { ocm10gfCntrEntry 5 }

        ocm10gfTotPktRcvd   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets received over the given
                         data channel."
                ::= { ocm10gfCntrEntry 6 }

        ocm10gfTotBadTrans  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data transmissions over the given
                         data channel."
                ::= { ocm10gfCntrEntry 7 }

        ocm10gfBadPktRcvd   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data packets received over the given
                         data channel."
                ::= { ocm10gfCntrEntry 8 }

        ocm10gfBytesSent    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of bytes sent over the given
                         data channel."
                ::= { ocm10gfCntrEntry 9 }

        ocm10gfBytesRcvd    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of data bytes received over the given
                         data channel."
                ::= { ocm10gfCntrEntry 10 }

        ocm10gfMsgsDlvrd    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of complete messages delivered over the
                         given data channel."
                ::= { ocm10gfCntrEntry 11 }

        ocm10gfClearCntrs   OBJECT-TYPE
                SYNTAX  ResetType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "If the value is reset, all software counters for this
                         15 minute interval are reset to zero.  A get on this
                         will always return other"
                ::= { ocm10gfCntrEntry 12 }

        ocm10gfPmTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF Ocm10gfPmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entry for the software counters."
                ::= { ocm10gfPerf 4 }

        ocm10gfPmEntry      OBJECT-TYPE
                SYNTAX  Ocm10gfPmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { ocm10gfPmLocation, ocm10gfPmShelf, ocm10gfPmSlot }
                ::= { ocm10gfPmTable 1 }

        Ocm10gfPmEntry     ::=
                SEQUENCE
                {
                        ocm10gfPmLocation               CardLocation,
                        ocm10gfPmShelf                  CardShelf,
                        ocm10gfPmSlot                   INTEGER,
                        ocm10gfPmNumIntervals           INTEGER,
                        ocm10gfPmLinkRxPwr              DisplayString,
                        ocm10gfPmLinkTxPwr              DisplayString,
                        ocm10gfPmLinkFecErrors          DisplayString,
                        ocm10gfPmLinkUncorrectedFecErrs Counter,
                        ocm10gfPmLinkCorrectedFecErrs   DisplayString,
                        ocm10gfPmLinkCorrectedOnesErr   DisplayString,
                        ocm10gfPmLinkErredSeconds       Counter,
                        ocm10gfPmCpeRxPwr               DisplayString,
                        ocm10gfPmCpeTxPwr               DisplayString,
                        ocm10gfPmCpeSonetRxB2Errs       DisplayString,
                        ocm10gfPmCpeSonetTxB2Errs       DisplayString,
                        ocm10gfPmCpe10GbeRxTotalPkts    DisplayString,
                        ocm10gfPmCpe10GbeRxErredPkts    DisplayString,
                        ocm10gfPmCpe10GbeTxTotalPkts    DisplayString,
                        ocm10gfPmCpe10gbeTxErredPkts    DisplayString,
                        ocm10gfPmCpeErredSeconds        Counter,
                        ocm10gfClearPmCntrs             ResetType
                }

        ocm10gfPmLocation   OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the OCM10GF card.  The values are: Local
                         or Remote.  The system automatically determines the
                         right value for this entry based on the known
                         OCM10GF cards."
                ::= { ocm10gfPmEntry 1 }

        ocm10gfPmShelf      OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2.
                         The system automatically determines the right value
                         for this entry based on the known (available) OCM10GF
                         cards."
                ::= { ocm10gfPmEntry 2 }

        ocm10gfPmSlot       OBJECT-TYPE 
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  Valid
                         values are: 1 to 17.  The system automatically
                         determines the right value for this entry based
                         on the known (available) OCM10GF cards."
                ::= { ocm10gfPmEntry 3 }


        ocm10gfPmNumIntervals OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        ""
                ::= { ocm10gfPmEntry 4 }

        ocm10gfPmLinkRxPwr OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        ""
                ::= { ocm10gfPmEntry 5 }

        ocm10gfPmLinkTxPwr OBJECT-TYPE 
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        ""
                ::= { ocm10gfPmEntry 6 }

        ocm10gfPmLinkFecErrors OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        ""
                ::= { ocm10gfPmEntry 7 }

        ocm10gfPmLinkUncorrectedFecErrs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        ""
                ::= { ocm10gfPmEntry 8 }

        ocm10gfPmLinkCorrectedFecErrs OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        ""
                ::= { ocm10gfPmEntry 9 }

        ocm10gfPmLinkCorrectedOnesErr OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        ""
                ::= { ocm10gfPmEntry 10 }

        ocm10gfPmLinkErredSeconds OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        ""
                ::= { ocm10gfPmEntry 11 }

        ocm10gfPmCpeRxPwr OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        ""
                ::= { ocm10gfPmEntry 12 }

        ocm10gfPmCpeTxPwr OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        ""
                ::= { ocm10gfPmEntry 13 }

        ocm10gfPmCpeSonetRxB2Errs OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        ""
                ::= { ocm10gfPmEntry 14 }

        ocm10gfPmCpeSonetTxB2Errs OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        ""
                ::= { ocm10gfPmEntry 15 }

        ocm10gfPmCpe10GbeRxTotalPkts OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        ""
                ::= { ocm10gfPmEntry 16 }

        ocm10gfPmCpe10GbeRxErredPkts OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        ""
                ::= { ocm10gfPmEntry 17 }

        ocm10gfPmCpe10GbeTxTotalPkts OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        ""
                ::= { ocm10gfPmEntry 18 }

        ocm10gfPmCpe10gbeTxErredPkts OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        ""
                ::= { ocm10gfPmEntry 19 }

        ocm10gfPmCpeErredSeconds OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        ""
                ::= { ocm10gfPmEntry 20 }

        ocm10gfClearPmCntrs   OBJECT-TYPE
                SYNTAX  ResetType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "If the value is reset, all PM counters for this
                         port are reset to zero.  A get on this will always
                         return other"
                ::= { ocm10gfPmEntry 21 }

        -- The elements in the ocm2Perf subgroup of the current subgroup

        ocm2NumEvents    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         OCM2 modules in this time slot (15 minutes)."
                ::= { ocm2Perf 1 }
    

        ocm2PerfTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF Ocm2PerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each OCM2 module."
                ::= { ocm2Perf 2 }

        ocm2PerfEntry    OBJECT-TYPE
                SYNTAX  Ocm2PerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { ocm2PerfLocation, ocm2PerfShelf, ocm2PerfSlot }
                ::= { ocm2PerfTable 1 }

        Ocm2PerfEntry    ::=
                SEQUENCE
                {
                        ocm2PerfLocation         CardLocation,
                        ocm2PerfShelf            CardShelf,
                        ocm2PerfSlot             INTEGER,
                        ocm2PerfState            CardState,
                        ocm2PerfStatus           CardStatus,
                        ocm2LastBootTime         DateAndTime,
                        ocm2AvailTime            Counter,
                        ocm2ErrFreeSecs          Counter
                }

        ocm2PerfLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the module.  Choices are local or remote."
                ::= { ocm2PerfEntry 1 }

        ocm2PerfShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the module is in."
                ::= { ocm2PerfEntry 2 }

        ocm2PerfSlot     OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the module is in."
                ::= { ocm2PerfEntry 3 }

        ocm2PerfState    OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The state of the OCM2 module.  The states are:
                         online, offline, empty, loopback or diag."
                ::= { ocm2PerfEntry 4 }

        ocm2PerfStatus   OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The status of the OCM2 module.  This status represents
                         the status of the OCM2 module and in general is
                         different from the status of the system."
                ::= { ocm2PerfEntry 5 }

        ocm2LastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this module."
                ::= { ocm2PerfEntry 6 }

        ocm2AvailTime    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this module has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { ocm2PerfEntry 7 }

        ocm2ErrFreeSecs  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this module has not experienced any alarms."
                ::= { ocm2PerfEntry 8 }

        ocm2CntrTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF Ocm2CntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entry for the software counters."
                ::= { ocm2Perf 3 }

        ocm2CntrEntry     OBJECT-TYPE
                SYNTAX  Ocm2CntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { ocm2CntrLocation, ocm2CntrShelf, ocm2CntrSlot, ocm2CntrType }
                ::= { ocm2CntrTable 1 }

        Ocm2CntrEntry     ::=
                SEQUENCE
                {
                        ocm2CntrLocation          CardLocation,
                        ocm2CntrShelf             CardShelf,
                        ocm2CntrSlot              INTEGER,
                        ocm2CntrType              INTEGER,
                        ocm2TotPktSent            Counter,
                        ocm2TotPktRcvd            Counter,
                        ocm2TotBadTrans           Counter,
                        ocm2BadPktRcvd            Counter,
                        ocm2BytesSent             Counter,
                        ocm2BytesRcvd             Counter,
                        ocm2MsgsDlvrd             Counter,
                        ocm2ClearCntrs            ResetType
                }

        ocm2CntrLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the OCM2 card.  The values are: Local
                         or Remote.  The system automatically determines the
                         right value for this entry based on the known
                         OCM2 cards."
                ::= { ocm2CntrEntry 1 }

        ocm2CntrShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2.
                         The system automatically determines the right value
                         for this entry based on the known (available) OCM2
                         cards."
                ::= { ocm2CntrEntry 2 }

        ocm2CntrSlot     OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  Valid
                         values are: 1 to 17.  The system automatically
                         determines the right value for this entry based
                         on the known (available) OCM2 cards."
                ::= { ocm2CntrEntry 3 }

        ocm2CntrType     OBJECT-TYPE
                SYNTAX  INTEGER { spi(1), ibm1(2), ibm2(3), hdlc(4) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The type of the software counter data in this row."
                ::= { ocm2CntrEntry 4 }

        ocm2TotPktSent   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets sent over the given data
                         channel."
                ::= { ocm2CntrEntry 5 }

        ocm2TotPktRcvd   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets received over the given
                         data channel."
                ::= { ocm2CntrEntry 6 }

        ocm2TotBadTrans  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data transmissions over the given
                         data channel."
                ::= { ocm2CntrEntry 7 }

        ocm2BadPktRcvd   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data packets received over the given
                         data channel."
                ::= { ocm2CntrEntry 8 }

        ocm2BytesSent    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of bytes sent over the given
                         data channel."
                ::= { ocm2CntrEntry 9 }

        ocm2BytesRcvd    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of data bytes received over the given
                         data channel."
                ::= { ocm2CntrEntry 10 }

        ocm2MsgsDlvrd    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of complete messages delivered over the
                         given data channel."
                ::= { ocm2CntrEntry 11 }

        ocm2ClearCntrs   OBJECT-TYPE
                SYNTAX  ResetType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "If the value is reset, all software counters for this
                         15 minute interval are reset to zero.  A get on this
                         will always return other"
                ::= { ocm2CntrEntry 12 }

        ocm2PmTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF Ocm2PmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entry for the software counters."
                ::= { ocm2Perf 4 }

        ocm2PmEntry      OBJECT-TYPE
                SYNTAX  Ocm2PmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { ocm2PmLocation, ocm2PmShelf, ocm2PmSlot, ocm2PmLink }
                ::= { ocm2PmTable 1 }

        Ocm2PmEntry     ::=
                SEQUENCE
                {
                        ocm2PmLocation              CardLocation,
                        ocm2PmShelf                 CardShelf,
                        ocm2PmSlot                  CardSlot,
                        ocm2PmLink                  INTEGER,
                        ocm2PmLinkRxPwr             DisplayString,
                        ocm2PmLinkTxPwr             DisplayString,
                        ocm2PmCpeRxPwr              DisplayString,
                        ocm2PmCpeTxPwr              DisplayString,
                        ocm2PmNumLinkRxIntervals    INTEGER,
                        ocm2PmLinkRxErrors          DisplayString,
                        ocm2PmLinkRxErredSeconds    Counter,
                        ocm2PmNumCpeRxIntervals     INTEGER,
                        ocm2PmCpeRxErrors           DisplayString,
                        ocm2PmCpeRxErredSeconds     Counter,
                        ocm2PmNumCpeTxIntervals     INTEGER,
                        ocm2PmCpeTxErrors           DisplayString,
                        ocm2PmCpeTxErredSeconds     Counter,
                        ocm2ClearPmCntrs            ResetType
                }

        ocm2PmLocation   OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the OCM2 card.  The values are: Local
                         or Remote.  The system automatically determines the
                         right value for this entry based on the known
                         OCM2 cards."
                ::= { ocm2PmEntry 1 }

        ocm2PmShelf      OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2.
                         The system automatically determines the right value
                         for this entry based on the known (available) OCM2
                         cards."
                ::= { ocm2PmEntry 2 }

        ocm2PmSlot       OBJECT-TYPE 
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  Valid
                         values are: 1 to 17.  The system automatically
                         determines the right value for this entry based
                         on the known (available) OCM2 cards."
                ::= { ocm2PmEntry 3 }


        ocm2PmLink OBJECT-TYPE
                SYNTAX  INTEGER { link1(1), link2(2) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The link for which statistics are for."
                ::= { ocm2PmEntry 4 }

        ocm2PmLinkRxPwr OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Link receive power."
                ::= { ocm2PmEntry 5 }

        ocm2PmLinkTxPwr OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Link transmit power."
                ::= { ocm2PmEntry 6 }

        ocm2PmCpeRxPwr OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CPE receive power."
                ::= { ocm2PmEntry 7 }

        ocm2PmCpeTxPwr OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CPE transmit power."
                ::= { ocm2PmEntry 8 }

        ocm2PmNumLinkRxIntervals OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The of intervals (seconds) over which the link Rx 
                         statistics have been accumulated."
                ::= { ocm2PmEntry 9 }

        ocm2PmLinkRxErrors OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Link receive errors."
                ::= { ocm2PmEntry 10 }

        ocm2PmLinkRxErredSeconds OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Link receive errored seconds."
                ::= { ocm2PmEntry 11 }

        ocm2PmNumCpeRxIntervals OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The of intervals (seconds) over which the CPE Rx 
                         statistics have been accumulated."
                ::= { ocm2PmEntry 12 }

        ocm2PmCpeRxErrors OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CPE receive errors."
                ::= { ocm2PmEntry 13 }

        ocm2PmCpeRxErredSeconds OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CPE receive errored seconds."
                ::= { ocm2PmEntry 14 }

        ocm2PmNumCpeTxIntervals OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The of intervals (seconds) over which the CPE Tx 
                         statistics have been accumulated."
                ::= { ocm2PmEntry 15 }

        ocm2PmCpeTxErrors OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CPE transmit errors."
                ::= { ocm2PmEntry 16 }

        ocm2PmCpeTxErredSeconds OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CPE transmit errored seconds."
                ::= { ocm2PmEntry 17 }

        ocm2ClearPmCntrs   OBJECT-TYPE
                SYNTAX  ResetType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "If the value is reset, all PM counters for this
                         port are reset to zero.  A get on this will always
                         return other"
                ::= { ocm2PmEntry 18 }

        -- The elements in the oscPerf subgroup of the current subgroup

        oscNumEvents    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         OSC modules in this time slot (15 minutes)."
                ::= { oscPerf 1 }
    

        oscPerfTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF OscPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each OSC module."
                ::= { oscPerf 2 }

        oscPerfEntry    OBJECT-TYPE
                SYNTAX  OscPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { oscPerfLocation, oscPerfShelf, oscPerfSlot }
                ::= { oscPerfTable 1 }

        OscPerfEntry    ::=
                SEQUENCE
                {
                        oscPerfLocation         CardLocation,
                        oscPerfShelf            CardShelf,
                        oscPerfSlot             INTEGER,
                        oscPerfState            CardState,
                        oscPerfStatus           CardStatus,
                        oscLastBootTime         DateAndTime,
                        oscAvailTime            Counter,
                        oscErrFreeSecs          Counter
                }

        oscPerfLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the module.  Choices are local or remote."
                ::= { oscPerfEntry 1 }

        oscPerfShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the module is in."
                ::= { oscPerfEntry 2 }

        oscPerfSlot     OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the module is in."
                ::= { oscPerfEntry 3 }

        oscPerfState    OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The state of the OSC module.  The states are:
                         online, offline, empty, loopback or diag."
                ::= { oscPerfEntry 4 }

        oscPerfStatus   OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The status of the OSC module.  This status represents
                         the status of the OSC module and in general is
                         different from the status of the system."
                ::= { oscPerfEntry 5 }

        oscLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this module."
                ::= { oscPerfEntry 6 }

        oscAvailTime    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this module has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { oscPerfEntry 7 }

        oscErrFreeSecs  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this module has not experienced any alarms."
                ::= { oscPerfEntry 8 }

        oscCntrTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF OscCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entry for the software counters."
                ::= { oscPerf 3 }

        oscCntrEntry     OBJECT-TYPE
                SYNTAX  OscCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { oscCntrLocation, oscCntrShelf, oscCntrSlot, oscCntrType }
                ::= { oscCntrTable 1 }

        OscCntrEntry     ::=
                SEQUENCE
                {
                        oscCntrLocation          CardLocation,
                        oscCntrShelf             CardShelf,
                        oscCntrSlot              INTEGER,
                        oscCntrType              INTEGER,
                        oscTotPktSent            Counter,
                        oscTotPktRcvd            Counter,
                        oscTotBadTrans           Counter,
                        oscBadPktRcvd            Counter,
                        oscBytesSent             Counter,
                        oscBytesRcvd             Counter,
                        oscMsgsDlvrd             Counter,
                        oscClearCntrs            ResetType
                }

        oscCntrLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the OSC card.  The values are: Local
                         or Remote.  The system automatically determines the
                         right value for this entry based on the known
                         OSC cards."
                ::= { oscCntrEntry 1 }

        oscCntrShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2.
                         The system automatically determines the right value
                         for this entry based on the known (available) OSC
                         cards."
                ::= { oscCntrEntry 2 }

        oscCntrSlot     OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  Valid
                         values are: 1 to 17.  The system automatically
                         determines the right value for this entry based
                         on the known (available) OSC cards."
                ::= { oscCntrEntry 3 }

        oscCntrType     OBJECT-TYPE
                SYNTAX  INTEGER { spi(1), ibm(2), hdlc(3) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The type of the software counter data in this row."
                ::= { oscCntrEntry 4 }

        oscTotPktSent   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets sent over the given data
                         channel."
                ::= { oscCntrEntry 5 }

        oscTotPktRcvd   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets received over the given
                         data channel."
                ::= { oscCntrEntry 6 }

        oscTotBadTrans  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data transmissions over the given
                         data channel."
                ::= { oscCntrEntry 7 }

        oscBadPktRcvd   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data packets received over the given
                         data channel."
                ::= { oscCntrEntry 8 }

        oscBytesSent    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of bytes sent over the given
                         data channel."
                ::= { oscCntrEntry 9 }

        oscBytesRcvd    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of data bytes received over the given
                         data channel."
                ::= { oscCntrEntry 10 }

        oscMsgsDlvrd    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of complete messages delivered over the
                         given data channel."
                ::= { oscCntrEntry 11 }

        oscClearCntrs   OBJECT-TYPE
                SYNTAX  ResetType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "If the value is reset, all software counters for this
                         15 minute interval are reset to zero.  A get on this
                         will always return other"
                ::= { oscCntrEntry 12 }

        oscPmTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF OscPmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entry for the software counters."
                ::= { oscPerf 4 }

        oscPmEntry      OBJECT-TYPE
                SYNTAX  OscPmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { oscPmLocation, oscPmShelf, oscPmSlot }
                ::= { oscPmTable 1 }

        OscPmEntry     ::=
                SEQUENCE
                {
                        oscPmLocation          CardLocation,
                        oscPmShelf             CardShelf,
                        oscPmSlot              INTEGER,
                        oscPmErrors            Counter,
                        oscPmErredSecs         Counter,
                        oscStartTime           DateAndTime,
                        oscClearPmCntrs        ResetType
                }

        oscPmLocation   OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the OSC card.  The values are: Local
                         or Remote.  The system automatically determines the
                         right value for this entry based on the known
                         OSC cards."
                ::= { oscPmEntry 1 }

        oscPmShelf      OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2.
                         The system automatically determines the right value
                         for this entry based on the known (available) OSC
                         cards."
                ::= { oscPmEntry 2 }

        oscPmSlot       OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  Valid
                         values are: 1 to 17.  The system automatically
                         determines the right value for this entry based
                         on the known (available) OSC cards."
                ::= { oscPmEntry 3 }

        oscPmErrors     OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of packets errors since port last came online."
                ::= { oscPmEntry 4 }

        oscPmErredSecs  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of erred seconds since port last came online."
                ::= { oscPmEntry 5 }

        oscStartTime    OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date/time the port came last online."
                ::= { oscPmEntry 6 }

        oscClearPmCntrs   OBJECT-TYPE
                SYNTAX  ResetType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "If the value is reset, all PM counters for this
                         port are reset to zero.  A get on this will always
                         return other"
                ::= { oscPmEntry 7 }


        -- The elements in the ocm4gPerf subgroup of the current subgroup

        ocm4gNumEvents    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         OCM4G modules in this time slot (15 minutes)."
                ::= { ocm4gPerf 1 }
    

        ocm4gPerfTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF Ocm4gPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each OCM4G module."
                ::= { ocm4gPerf 2 }

        ocm4gPerfEntry    OBJECT-TYPE
                SYNTAX  Ocm4gPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { ocm4gPerfLocation, ocm4gPerfShelf, ocm4gPerfSlot }
                ::= { ocm4gPerfTable 1 }

        Ocm4gPerfEntry    ::=
                SEQUENCE
                {
                        ocm4gPerfLocation         INTEGER,
                        ocm4gPerfShelf            CardShelf,
                        ocm4gPerfSlot             INTEGER,
                        ocm4gPerfState            CardState,
                        ocm4gPerfStatus           CardStatus,
                        ocm4gLastBootTime         DateAndTime,
                        ocm4gAvailTime            Counter,
                        ocm4gErrFreeSecs          Counter
                }

        ocm4gPerfLocation OBJECT-TYPE
                SYNTAX  INTEGER { local(1) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the module.  Choices are local or remote."
                ::= { ocm4gPerfEntry 1 }

        ocm4gPerfShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the module is in."
                ::= { ocm4gPerfEntry 2 }

        ocm4gPerfSlot     OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the module is in."
                ::= { ocm4gPerfEntry 3 }

        ocm4gPerfState    OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The state of the OCM4G module.  The states are:
                         online, offline, empty, loopback or diag."
                ::= { ocm4gPerfEntry 4 }

        ocm4gPerfStatus   OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The status of the OCM4G module.  This status represents
                         the status of the OCM4G module and in general is
                         different from the status of the system."
                ::= { ocm4gPerfEntry 5 }

        ocm4gLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this module."
                ::= { ocm4gPerfEntry 6 }

        ocm4gAvailTime    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this module has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { ocm4gPerfEntry 7 }

        ocm4gErrFreeSecs  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this module has not experienced any alarms."
                ::= { ocm4gPerfEntry 8 }

        ocm4gCntrTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF Ocm4gCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entry for the software counters."
                ::= { ocm4gPerf 3 }

        ocm4gCntrEntry     OBJECT-TYPE
                SYNTAX  Ocm4gCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { ocm4gCntrLocation, ocm4gCntrShelf, ocm4gCntrSlot, ocm4gCntrType }
                ::= { ocm4gCntrTable 1 }

        Ocm4gCntrEntry     ::=
                SEQUENCE
                {
                        ocm4gCntrLocation          INTEGER,
                        ocm4gCntrShelf             CardShelf,
                        ocm4gCntrSlot              INTEGER,
                        ocm4gCntrType              INTEGER,
                        ocm4gTotPktSent            Counter,
                        ocm4gTotPktRcvd            Counter,
                        ocm4gTotBadTrans           Counter,
                        ocm4gBadPktRcvd            Counter,
                        ocm4gBytesSent             Counter,
                        ocm4gBytesRcvd             Counter,
                        ocm4gMsgsDlvrd             Counter,
                        ocm4gClearCntrs            ResetType
                }

        ocm4gCntrLocation OBJECT-TYPE
                SYNTAX  INTEGER { local(1) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the OCM4G card.  The values are: Local
                         or Remote.  The system automatically determines the
                         right value for this entry based on the known
                         OCM4G cards."
                ::= { ocm4gCntrEntry 1 }

        ocm4gCntrShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2.
                         The system automatically determines the right value
                         for this entry based on the known (available) OCM4G
                         cards."
                ::= { ocm4gCntrEntry 2 }

        ocm4gCntrSlot     OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  Valid
                         values are: 1 to 17.  The system automatically
                         determines the right value for this entry based
                         on the known (available) OCM4G cards."
                ::= { ocm4gCntrEntry 3 }

        ocm4gCntrType     OBJECT-TYPE
                SYNTAX  INTEGER { spi(1), ibm1(2), ibm2(3), hdlc(4) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The type of the software counter data in this row."
                ::= { ocm4gCntrEntry 4 }

        ocm4gTotPktSent   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets sent over the given data
                         channel."
                ::= { ocm4gCntrEntry 5 }

        ocm4gTotPktRcvd   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets received over the given
                         data channel."
                ::= { ocm4gCntrEntry 6 }

        ocm4gTotBadTrans  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data transmissions over the given
                         data channel."
                ::= { ocm4gCntrEntry 7 }

        ocm4gBadPktRcvd   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data packets received over the given
                         data channel."
                ::= { ocm4gCntrEntry 8 }

        ocm4gBytesSent    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of bytes sent over the given
                         data channel."
                ::= { ocm4gCntrEntry 9 }

        ocm4gBytesRcvd    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of data bytes received over the given
                         data channel."
                ::= { ocm4gCntrEntry 10 }

        ocm4gMsgsDlvrd    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of complete messages delivered over the
                         given data channel."
                ::= { ocm4gCntrEntry 11 }

        ocm4gClearCntrs   OBJECT-TYPE
                SYNTAX  ResetType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "If the value is reset, all software counters for this
                         15 minute interval are reset to zero.  A get on this
                         will always return other"
                ::= { ocm4gCntrEntry 12 }

        ocm4gPmTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF Ocm4gPmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entry for the software counters."
                ::= { ocm4gPerf 4 }

        ocm4gPmEntry      OBJECT-TYPE
                SYNTAX  Ocm4gPmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { ocm4gPmLocation, ocm4gPmShelf, ocm4gPmSlot, ocm4gPmLink }
                ::= { ocm4gPmTable 1 }

        Ocm4gPmEntry     ::=
                SEQUENCE
                {
                        ocm4gPmLocation              INTEGER,
                        ocm4gPmShelf                 CardShelf,
                        ocm4gPmSlot                  CardSlot,
                        ocm4gPmLink                  INTEGER,
                        ocm4gPmLinkRxPwr             DisplayString,
                        ocm4gPmLinkTxPwr             DisplayString,
                        ocm4gPmCpeRxPwr              DisplayString,
                        ocm4gPmCpeTxPwr              DisplayString,
                        ocm4gPmNumLinkRxIntervals    INTEGER,
                        ocm4gPmLinkRxErrors          DisplayString,
                        ocm4gPmLinkRxErredSeconds    Counter,
                        ocm4gPmNumCpeRxIntervals     INTEGER,
                        ocm4gPmCpeRxErrors           DisplayString,
                        ocm4gPmCpeRxErredSeconds     Counter,
                        ocm4gPmNumCpeTxIntervals     INTEGER,
                        ocm4gPmCpeTxErrors           DisplayString,
                        ocm4gPmCpeTxErredSeconds     Counter,
                        ocm4gClearPmCntrs            ResetType
                }

        ocm4gPmLocation   OBJECT-TYPE
                SYNTAX  INTEGER { local(1) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the OCM4G card.  The values are: Local
                         or Remote.  The system automatically determines the
                         right value for this entry based on the known
                         OCM4G cards."
                ::= { ocm4gPmEntry 1 }

        ocm4gPmShelf      OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2.
                         The system automatically determines the right value
                         for this entry based on the known (available) OCM4G
                         cards."
                ::= { ocm4gPmEntry 2 }

        ocm4gPmSlot       OBJECT-TYPE 
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  Valid
                         values are: 1 to 17.  The system automatically
                         determines the right value for this entry based
                         on the known (available) OCM4G cards."
                ::= { ocm4gPmEntry 3 }


        ocm4gPmLink OBJECT-TYPE
                SYNTAX  INTEGER { link1(1), link2(2) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The link for which statistics are for."
                ::= { ocm4gPmEntry 4 }

        ocm4gPmLinkRxPwr OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Link receive power."
                ::= { ocm4gPmEntry 5 }

        ocm4gPmLinkTxPwr OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Link transmit power."
                ::= { ocm4gPmEntry 6 }

        ocm4gPmCpeRxPwr OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CPE receive power."
                ::= { ocm4gPmEntry 7 }

        ocm4gPmCpeTxPwr OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CPE transmit power."
                ::= { ocm4gPmEntry 8 }

        ocm4gPmNumLinkRxIntervals OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The of intervals (seconds) over which the link Rx 
                         statistics have been accumulated."
                ::= { ocm4gPmEntry 9 }

        ocm4gPmLinkRxErrors OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Link receive errors."
                ::= { ocm4gPmEntry 10 }

        ocm4gPmLinkRxErredSeconds OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Link receive errored seconds."
                ::= { ocm4gPmEntry 11 }

        ocm4gPmNumCpeRxIntervals OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The of intervals (seconds) over which the CPE Rx 
                         statistics have been accumulated."
                ::= { ocm4gPmEntry 12 }

        ocm4gPmCpeRxErrors OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CPE receive errors."
                ::= { ocm4gPmEntry 13 }

        ocm4gPmCpeRxErredSeconds OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CPE receive errored seconds."
                ::= { ocm4gPmEntry 14 }

        ocm4gPmNumCpeTxIntervals OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The of intervals (seconds) over which the CPE Tx 
                         statistics have been accumulated."
                ::= { ocm4gPmEntry 15 }

        ocm4gPmCpeTxErrors OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CPE transmit errors."
                ::= { ocm4gPmEntry 16 }

        ocm4gPmCpeTxErredSeconds OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CPE transmit errored seconds."
                ::= { ocm4gPmEntry 17 }

        ocm4gClearPmCntrs   OBJECT-TYPE
                SYNTAX  ResetType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "If the value is reset, all PM counters for this
                         port are reset to zero.  A get on this will always
                         return other"
                ::= { ocm4gPmEntry 18 }

        -- The elements in the oetPerf subgroup of the current subgroup

        oetNumEvents    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         OET modules in this time slot (15 minutes)."
                ::= { oetPerf 1 }
    

        oetPerfTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF OetPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each OET module."
                ::= { oetPerf 2 }

        oetPerfEntry    OBJECT-TYPE
                SYNTAX  OetPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { oetPerfLocation, oetPerfShelf, oetPerfSlot }
                ::= { oetPerfTable 1 }

        OetPerfEntry    ::=
                SEQUENCE
                {
                        oetPerfLocation         CardLocation,
                        oetPerfShelf            CardShelf,
                        oetPerfSlot             INTEGER,
                        oetPerfState            CardState,
                        oetPerfStatus           CardStatus,
                        oetLastBootTime         DateAndTime,
                        oetAvailTime            Counter,
                        oetErrFreeSecs          Counter
                }

        oetPerfLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the module.  Choices are local or remote."
                ::= { oetPerfEntry 1 }

        oetPerfShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the module is in."
                ::= { oetPerfEntry 2 }

        oetPerfSlot     OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the module is in."
                ::= { oetPerfEntry 3 }

        oetPerfState    OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The state of the OET module.  The states are:
                         online, offline, empty, loopback or diag."
                ::= { oetPerfEntry 4 }

        oetPerfStatus   OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The status of the OET module.  This status represents
                         the status of the OET module and in general is
                         different from the status of the system."
                ::= { oetPerfEntry 5 }

        oetLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this module."
                ::= { oetPerfEntry 6 }

        oetAvailTime    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this module has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { oetPerfEntry 7 }

        oetErrFreeSecs  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this module has not experienced any alarms."
                ::= { oetPerfEntry 8 }

        oetPmLinkTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF OetPmLinkEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entry for the OET Link ports."
                ::= { oetPerf 3 }

        oetPmLinkEntry      OBJECT-TYPE
                SYNTAX  OetPmLinkEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { oetPmLinkLocation, oetPmLinkShelf, oetPmLinkSlot, oetPmLink }
                ::= { oetPmLinkTable 1 }

        OetPmLinkEntry     ::=
                SEQUENCE
                {
                        oetPmLinkLocation              CardLocation,
                        oetPmLinkShelf                 CardShelf,
                        oetPmLinkSlot                  CardSlot,
                        oetPmLink                      INTEGER,
                        oetPmLinkNumIntervals          INTEGER,
                        oetPmLinkRxPwr                 DisplayString,
                        oetPmLinkRxBytes               DisplayString,
                        oetPmLinkRxFcsErrs             DisplayString,
                        oetPmLinkTxPwr                 DisplayString,
                        oetPmLinkTxTemp                DisplayString,
                        oetPmLinkTxBytes               DisplayString,
                        oetPmLinkFecTx                 DisplayString,
                        oetPmLinkFecCorrected1s        INTEGER,
                        oetPmLinkFecCorrected0s        INTEGER,
                        oetPmLinkFecCorrectedBit       INTEGER,
                        oetPmLinkFecCorrectedByte      INTEGER,
                        oetPmLinkFecUncorrectedByte    INTEGER,
                        oetPmLinkFecBlock              INTEGER
                }
                        
        oetPmLinkLocation   OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the OET card.  The values are: Local
                         or Remote.  The system automatically determines the
                         right value for this entry based on the known
                         OET cards."
                ::= { oetPmLinkEntry 1 }

        oetPmLinkShelf      OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2.
                         The system automatically determines the right value
                         for this entry based on the known (available) OET
                         cards."
                ::= { oetPmLinkEntry 2 }

        oetPmLinkSlot       OBJECT-TYPE 
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  Valid
                         values are: 1 to 17.  The system automatically
                         determines the right value for this entry based
                         on the known (available) OET cards."
                ::= { oetPmLinkEntry 3 }


        oetPmLink OBJECT-TYPE
                SYNTAX  INTEGER { linkA(11), linkB(12) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The link for which the statistics are for."
                ::= { oetPmLinkEntry 4 }

        oetPmLinkNumIntervals OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The of intervals (seconds) over which the link 
                         statistics have been accumulated."
                ::= { oetPmLinkEntry 5 }

        oetPmLinkRxPwr OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Link receive power."
                ::= { oetPmLinkEntry 6 }

        oetPmLinkRxBytes OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Link Rx Bytes."
                ::= { oetPmLinkEntry 7 }

        oetPmLinkRxFcsErrs OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Link Rx FCS Errors."
                ::= { oetPmLinkEntry 8 }

        oetPmLinkTxPwr OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Link Tx power."
                ::= { oetPmLinkEntry 9 }

        oetPmLinkTxTemp OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Pump temp in C"
                ::= { oetPmLinkEntry 10 }

        oetPmLinkTxBytes OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Link Tx Bytes."
                ::= { oetPmLinkEntry 11 }

        oetPmLinkFecTx OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "FEC Link Tx."
                ::= { oetPmLinkEntry 12 }

        oetPmLinkFecCorrected1s OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "FEC Corrected '1's"
                ::= { oetPmLinkEntry 13 }

        oetPmLinkFecCorrected0s OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "FEC Corrected '0's"
                ::= { oetPmLinkEntry 14 }

        oetPmLinkFecCorrectedBit OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "FEC Corrected Bits"
                ::= { oetPmLinkEntry 15 }

        oetPmLinkFecCorrectedByte OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "FEC Corrected Bytes"
                ::= { oetPmLinkEntry 16 }

        oetPmLinkFecUncorrectedByte OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "FEC Uncorrected Bytes"
                ::= { oetPmLinkEntry 17 }

        oetPmLinkFecBlock OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "FEC Block Number"
                ::= { oetPmLinkEntry 18 }

        oetPmPortTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF OetPmPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entry for the OET CPE ports."
                ::= { oetPerf 4 }

        oetPmPortEntry      OBJECT-TYPE
                SYNTAX  OetPmPortEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { oetPmPortLocation, oetPmPortShelf, oetPmPortSlot, oetPmPortIndex }
                ::= { oetPmPortTable 1 }

        OetPmPortEntry     ::=
                SEQUENCE
                {
                        oetPmPortLocation              CardLocation,
                        oetPmPortShelf                 CardShelf,
                        oetPmPortSlot                  CardSlot,
                        oetPmPortIndex                 INTEGER,
                        oetPmPortNumIntervals          INTEGER,
                        oetPmPortRxPwr                 DisplayString,
                        oetPmPortRxBytes               DisplayString,
                        oetPmPortRxFcsErrs             DisplayString,
                        oetPmPortTxPwr                 DisplayString,
                        oetPmPortTxTemp                DisplayString,
                        oetPmPortTxBytes               DisplayString
                }
 
        oetPmPortLocation   OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the OET card.  The values are: Local
                         or Remote.  The system automatically determines the
                         right value for this entry based on the known
                         OET cards."
                ::= { oetPmPortEntry 1 }

        oetPmPortShelf      OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2.
                         The system automatically determines the right value
                         for this entry based on the known (available) OET
                         cards."
                ::= { oetPmPortEntry 2 }

        oetPmPortSlot       OBJECT-TYPE 
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  Valid
                         values are: 1 to 17.  The system automatically
                         determines the right value for this entry based
                         on the known (available) OET cards."
                ::= { oetPmPortEntry 3 }


        oetPmPortIndex OBJECT-TYPE
                SYNTAX  INTEGER { cpe(1), cpe(2), cpe(3), cpe(4), cpe(5), 
                     cpe(6), cpe(7), cpe(8), cpe(9), cpe(10)}
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port for which the statistics are for."
                ::= { oetPmPortEntry 4 }

        oetPmPortNumIntervals OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The of intervals (seconds) over which the port 
                         statistics have been accumulated."
                ::= { oetPmPortEntry 5 }

        oetPmPortRxPwr OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port receive power."
                ::= { oetPmPortEntry 6 }

        oetPmPortRxBytes OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port Rx Bytes."
                ::= { oetPmPortEntry 7 }

        oetPmPortRxFcsErrs OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port Rx FCS Errors."
                ::= { oetPmPortEntry 8 }

        oetPmPortTxPwr OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Link Tx power."
                ::= { oetPmPortEntry 9 }

        oetPmPortTxTemp OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Pump temp in C"
                ::= { oetPmPortEntry 10 }

        oetPmPortTxBytes OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Port Tx Bytes."
                ::= { oetPmPortEntry 11 }

        -- The elements in the systemHist subgroup of the historical subgroup

        sysHistTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF SysHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for historical
                         data collected for the overall system"
                ::= { systemHist 1 }

        sysHistEntry    OBJECT-TYPE
                SYNTAX  SysHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { sysHMode }
                ::= { sysHistTable 1 }

        SysHistEntry    ::=
                SEQUENCE
                {
                        sysHMode                HistoryMode,
                        sysHLastBootTime        DateAndTime,
                        sysHAvailTime           Counter,
                        sysHErrFreeSecs         Counter
                }

        sysHMode        OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { sysHistEntry 1 }

        sysHLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last system boot.  This time
                         represents the boot time of a CP card.  It is also
                         anonymous with the power-up cycle of the chassis."
                ::= { sysHistEntry 2 }

        sysHAvailTime   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds since the system has been up
                         and running.  The criteria for the system
                         available time is having at least one CP
                         running with atmost non-service affecting minor
                         alarm system status"
                ::= { sysHistEntry 3 }

        sysHErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that the device has not
                         experienced any alarms.  This counter is across all
                         cards in the chassis.  The system must be in Normal
                         status for this counter to be incremented."
                ::= { sysHistEntry 4 }

        -- The elements in the downloadHist subgroup of the historical subgroup

        dlHistTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF DlHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for historical
                         data collected for the download process"
                ::= { downloadHist 1 }

        dlHistEntry     OBJECT-TYPE
                SYNTAX  DlHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { dlHMode }
                ::= { dlHistTable 1 }

        DlHistEntry     ::=
                SEQUENCE
                {
                        dlHMode                 HistoryMode,
                        dlHOkDownloads          Counter,
                        dlHBadDownloads         Counter,
                        dlHLongestTime          Gauge,
                        dlHLongestSize          Gauge
                }

        dlHMode         OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { dlHistEntry 1 }

        dlHOkDownloads  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The number of successful downloads"
                ::= { dlHistEntry 2 }

        dlHBadDownloads OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The number of failed downloads"
                ::= { dlHistEntry 3 }

        dlHLongestTime  OBJECT-TYPE
                SYNTAX  Gauge
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Longest time for any download, in seconds"
                ::= { dlHistEntry 4 }

        dlHLongestSize  OBJECT-TYPE
                SYNTAX  Gauge
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Longest download size for any download, in bytes"
                ::= { dlHistEntry 5 }

        -- The elements in the cpHist subgroup of the historical subgroup

        cpHistTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF CpHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for historical
                         data collected for the communication card"
                ::= { cpHist 1 }

        cpHistEntry     OBJECT-TYPE
                SYNTAX  CpHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { cpHMode }
                ::= { cpHistTable 1 }

        CpHistEntry     ::=
                SEQUENCE
                {
                        cpHMode                 HistoryMode,
                        cpHNumEvents            Counter,
                        cpHTrapsSent            Counter,
                        cpHSNMPCmdsRcvd         Counter
                }

        cpHMode         OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { cpHistEntry 1 }

        cpHNumEvents    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of events received by the active CP"
                ::= { cpHistEntry 2 }

        cpHTrapsSent    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of traps sent by the active CP"
                ::= { cpHistEntry 3 }

        cpHSNMPCmdsRcvd OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of SNMP commands received by the active
                         CP."
                ::= { cpHistEntry 4 }

        cpHCntrTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF CpHCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entry for the software counters.  It is only
                         applicable to the active MPM card."
                ::= { cpHist 2 }

        cpHCntrEntry    OBJECT-TYPE
                SYNTAX  CpHCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { cpHCntrMode, cpCntrShelf, cpCntrSlot, cpCntrType }
                ::= { cpHCntrTable 1 }

        CpHCntrEntry    ::=
                SEQUENCE
                {
                        cpHCntrMode             HistoryMode,
                        cpHCntrShelf            CardShelf,
                        cpHCntrSlot             INTEGER,
                        cpHCntrType             INTEGER,
                        cpHTotPktSent           Counter,
                        cpHTotPktRcvd           Counter,
                        cpHBadPktRcvd           Counter,
                        cpHTotBadTrans          Counter,
                        cpHBytesSent            Counter,
                        cpHBytesRcvd            Counter,
                        cpHMsgsDlvrd            Counter,
                        cpHBufAllocFail         Counter,
                        cpHEcbAllocFail         Counter
                }

        cpHCntrMode     OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { cpHCntrEntry 1 }

        cpHCntrShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 10.
                         The system automatically determines the right value
                         for this entry based on the value of the current
                         active CP card."
                ::= { cpHCntrEntry 2 }

        cpHCntrSlot     OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in. The
                         system automatically determines the right value
                         for this entry based on the value of the current
                         active CP card."
                ::= { cpHCntrEntry 3 }

        cpHCntrType     OBJECT-TYPE
                SYNTAX  INTEGER { spi(1) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The type of the software counter data in this row.
                         The data is collected for the SPI data channels."
                ::= { cpHCntrEntry 4 }

        cpHTotPktSent   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets sent over the given data
                         channel."
                ::= { cpHCntrEntry 5 }

        cpHTotPktRcvd   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets received over the given
                         data channel."
                ::= { cpHCntrEntry 6 }

        cpHBadPktRcvd   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data packets received over the given
                         data channel."
                ::= { cpHCntrEntry 7 }

        cpHTotBadTrans  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data transmissions over the given
                         data channel."
                ::= { cpHCntrEntry 8 }

        cpHBytesSent    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of bytes sent over the given
                         data channel."
                ::= { cpHCntrEntry 9 }

        cpHBytesRcvd    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of data bytes received over the given
                         data channel."
                ::= { cpHCntrEntry 10 }

        cpHMsgsDlvrd    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of complete messages delivered over the
                         given data channel."
                ::= { cpHCntrEntry 11 }

        cpHBufAllocFail OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of buffer allocation failures for the given
                         data channel."
                ::= { cpHCntrEntry 12 }

        cpHEcbAllocFail OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of Event Control Block allocation failures
                         for the given data channel."
                ::= { cpHCntrEntry 13 }

        cpHHistTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF CpHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each communication processor"
                ::= { cpHist 3 }

        cpHHistEntry    OBJECT-TYPE
                SYNTAX  CpHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { cpHHistMode, cpHHistShelf, cpHHistSlot }
                ::= { cpHHistTable 1 }

        CpHHistEntry    ::=
                SEQUENCE
                {
                        cpHHistMode             HistoryMode,
                        cpHHistShelf            CardShelf,
                        cpHHistSlot             INTEGER,
                        cpHLastBootTime         DateAndTime,
                        cpHAvailTime            Counter,
                        cpHErrFreeSecs          Counter
                }

        cpHHistMode     OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { cpHHistEntry 1 }

        cpHHistShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 10"
                ::= { cpHHistEntry 2 }

        cpHHistSlot     OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { cpHHistEntry 3 }

        cpHLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this CP."
                ::= { cpHHistEntry 4 }

        cpHAvailTime    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this CP has been up and
             running."
                ::= { cpHHistEntry 5 }

        cpHErrFreeSecs  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this CP has not
                         experienced any alarms."
                ::= { cpHHistEntry 6 }

        -- The elements in the ccHist subgroup of the historical subgroup

        ccHistTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF CcHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for historical
                         data collected for the channel card"
                ::= { ccHist 1 }

        ccHistEntry     OBJECT-TYPE
                SYNTAX  CcHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { ccHMode }
                ::= { ccHistTable 1 }

        CcHistEntry     ::=
                SEQUENCE
                {
                        ccHMode                 HistoryMode,
                        ccHNumEvents            Counter
                }

        ccHMode         OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { ccHistEntry 1 }

        ccHNumEvents    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of events received for all CC's"
                ::= { ccHistEntry 2 }

        ccHCntrTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF CcHCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entry for the software counters."
                ::= { ccHist 2 }

        ccHCntrEntry    OBJECT-TYPE
                SYNTAX  CcHCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { ccHCntrMode, ccHCntrLocation, ccHCntrShelf,
                          ccHCntrSlot, ccHCntrType }
                ::= { ccHCntrTable 1 }

        CcHCntrEntry    ::=
                SEQUENCE
                {
                        ccHCntrMode             HistoryMode,
                        ccHCntrLocation         CardLocation,
                        ccHCntrShelf            CardShelf,
                        ccHCntrSlot             INTEGER,
                        ccHCntrType             INTEGER,
                        ccHTotPktSent           Counter,
                        ccHTotPktRcvd           Counter,
                        ccHBadPktRcvd           Counter,
                        ccHTotBadTrans          Counter,
                        ccHBytesSent            Counter,
                        ccHBytesRcvd            Counter,
                        ccHMsgsDlvrd            Counter,
                        ccHBufAllocFail         Counter,
                        ccHEcbAllocFail         Counter
                }

        ccHCntrMode     OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { ccHCntrEntry 1 }

        ccHCntrLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the CC card.  The values are: Local
                         or Remote.  The system automatically determines the
                         right value for this entry based on the known
                         CC cards."
                ::= { ccHCntrEntry 2 }

        ccHCntrShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 10.
                         The system automatically determines the right value
                         for this entry based on the known (available) CC
                         cards."
                ::= { ccHCntrEntry 3 }

        ccHCntrSlot     OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  The
                         system automatically determines the right value
                         for this entry based on the known (available)
                         CC cards."
                ::= { ccHCntrEntry 4 }

        ccHCntrType     OBJECT-TYPE
                SYNTAX  INTEGER { spi(1), iwm(2) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The type of the software counter data in this row.
                         The data is collected for the SPI data channels."
                ::= { ccHCntrEntry 5 }

        ccHTotPktSent   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets sent over the given data
                         channel."
                ::= { ccHCntrEntry 6 }

        ccHTotPktRcvd   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets received over the given
                         data channel."
                ::= { ccHCntrEntry 7 }

        ccHBadPktRcvd   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data packets received over the given
                         data channel."
                ::= { ccHCntrEntry 8 }

        ccHTotBadTrans  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data transmissions over the given
                         data channel."
                ::= { ccHCntrEntry 9 }

        ccHBytesSent    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of bytes sent over the given
                         data channel."
                ::= { ccHCntrEntry 10 }

        ccHBytesRcvd    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of data bytes received over the given
                         data channel."
                ::= { ccHCntrEntry 11 }

        ccHMsgsDlvrd    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of complete messages delivered over the
                         given data channel."
                ::= { ccHCntrEntry 12 }

        ccHBufAllocFail OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of buffer allocation failures for the given
                         data channel."
                ::= { ccHCntrEntry 13 }

        ccHEcbAllocFail OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of Event Control Block allocation failures
                         for the given data channel."
                ::= { ccHCntrEntry 14 }

        ccHHistTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF CcHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each channel card"
                ::= { ccHist 3 }

        ccHHistEntry    OBJECT-TYPE
                SYNTAX  CcHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { ccHHistMode, ccHHistLocation, ccHHistShelf,
                          ccHHistSlot }
                ::= { ccHHistTable 1 }

        CcHHistEntry    ::=
                SEQUENCE
                {
                        ccHHistMode             HistoryMode,
                        ccHHistLocation         CardLocation,
                        ccHHistShelf            CardShelf,
                        ccHHistSlot             INTEGER,
                        ccHLastBootTime         DateAndTime,
                        ccHAvailTime            Counter,
                        ccHErrFreeSecs          Counter
                }

        ccHHistMode     OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { ccHHistEntry 1 }

        ccHHistLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card.  Valid choices are Local
                         or Remote.  The system automatically selects this
                         value based on the known (available) CC cards."
                ::= { ccHHistEntry 2 }

        ccHHistShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 10"
                ::= { ccHHistEntry 3 }

        ccHHistSlot     OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { ccHHistEntry 4 }

        ccHLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this card."
                ::= { ccHHistEntry 5 }

        ccHAvailTime    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this CC has been up and
                         running."
                ::= { ccHHistEntry 6 }

        ccHErrFreeSecs  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this CC has not experienced
                         any alarms."
                ::= { ccHHistEntry 7 }

        -- The elements in the muxHist subgroup of the historical subgroup

        muxHistTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF MuxHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for historical
                         data collected for the mux/demux card"
                ::= { muxHist 1 }

        muxHistEntry    OBJECT-TYPE
                SYNTAX  MuxHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { muxHMode }
                ::= { muxHistTable 1 }

        MuxHistEntry    ::=
                SEQUENCE
                {
                        muxHMode                HistoryMode,
                        muxHNumEvents           Counter
                }

        muxHMode        OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { muxHistEntry 1 }

        muxHNumEvents   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         MUX's."
                ::= { muxHistEntry 2 }

        muxHHistTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF MuxHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each mux/demux card"
                ::= { muxHist 2 }

        muxHHistEntry   OBJECT-TYPE
                SYNTAX  MuxHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { muxHHistMode, muxHHistLocation, muxHHistShelf,
                          muxHHistSlot }
                ::= { muxHHistTable 1 }

        MuxHHistEntry   ::=
                SEQUENCE
                {
                        muxHHistMode            HistoryMode,
                        muxHHistLocation        CardLocation,
                        muxHHistShelf           CardShelf,
                        muxHHistSlot            INTEGER,
                        muxHHistType            INTEGER,
                        muxHLastBootTime        DateAndTime,
                        muxHAvailTime           Counter,
                        muxHErrFreeSecs         Counter
                }

        muxHHistMode    OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { muxHHistEntry 1 }

        muxHHistLocation  OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card.  Choices are local or
                         remote."
                ::= { muxHHistEntry 2 }

        muxHHistShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 10"
                ::= { muxHHistEntry 3 }

        muxHHistSlot    OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { muxHHistEntry 4 }

        muxHHistType    OBJECT-TYPE
                SYNTAX  INTEGER { mux(4), demux(5), w4cd(10), w2cmd(13), w4cm(21)}
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The type of the mux.  The choices are: mux or demux."
                ::= { muxHHistEntry 5 }

        muxHLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this card."
                ::= { muxHHistEntry 6 }

        muxHAvailTime   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this Mux has been up and
                         running."
                ::= { muxHHistEntry 7 }

        muxHErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this mux has not
                         experienced any alarms."
                ::= { muxHHistEntry 8 }

        -- The elements in the psHist subgroup of the historical subgroup

        psHistTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF PsHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for historical
                         data collected for the power supply card"
                ::= { psHist 1 }

        psHistEntry     OBJECT-TYPE
                SYNTAX  PsHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { psHMode }
                ::= { psHistTable 1 }

        PsHistEntry     ::=
                SEQUENCE
                {
                        psHMode                 HistoryMode,
                        psHNumEvents            Counter
                }

        psHMode         OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { psHistEntry 1 }

        psHNumEvents    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         Power Supplies."
                ::= { psHistEntry 2 }

        -- The elements in the fadmHist subgroup of the historical subgroup

        fadmHistTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF FadmHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for historical
                         data collected for the fadm card"
                ::= { fadmHist 1 }

        fadmHistEntry    OBJECT-TYPE
                SYNTAX  FadmHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { fadmHMode }
                ::= { fadmHistTable 1 }

        FadmHistEntry   ::=
                SEQUENCE
                {
                        fadmHMode               HistoryMode,
                        fadmHNumEvents          Counter
                }

        fadmHMode       OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { fadmHistEntry 1 }

        fadmHNumEvents  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         FADM's."
                ::= { fadmHistEntry 2 }

        fadmHHistTable  OBJECT-TYPE
                SYNTAX  SEQUENCE OF FadmHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each fadm card"
                ::= { fadmHist 2 }

        fadmHHistEntry  OBJECT-TYPE
                SYNTAX  FadmHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { fadmHHistMode, fadmHHistLocation, fadmHHistShelf,
                          fadmHHistSlot }
                ::= { fadmHHistTable 1 }

        FadmHHistEntry  ::=
                SEQUENCE
                {
                        fadmHHistMode           HistoryMode,
                        fadmHHistLocation       CardLocation,
                        fadmHHistShelf          CardShelf,
                        fadmHHistSlot           INTEGER,
                        fadmHLastBootTime       DateAndTime,
                        fadmHAvailTime          Counter,
                        fadmHErrFreeSecs        Counter
                }

        fadmHHistMode   OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { fadmHHistEntry 1 }

        fadmHHistLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card.  Choices are local or
                         remote."
                ::= { fadmHHistEntry 2 }

        fadmHHistShelf  OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 10"
                ::= { fadmHHistEntry 3 }

        fadmHHistSlot   OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { fadmHHistEntry 4 }

        fadmHLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this card."
                ::= { fadmHHistEntry 6 }

        fadmHAvailTime  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this Mux has been up and
                         running."
                ::= { fadmHHistEntry 7 }

        fadmHErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this mux has not
                         experienced any alarms."
                ::= { fadmHHistEntry 8 }

        -- The elements in the oppmHist subgroup of the historical subgroup

        oppmHistTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF OppmHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for historical
                         data collected for the oppm card"
                ::= { oppmHist 1 }

        oppmHistEntry   OBJECT-TYPE
                SYNTAX  OppmHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { oppmHMode }
                ::= { oppmHistTable 1 }

        OppmHistEntry   ::=
                SEQUENCE
                {
                        oppmHMode               HistoryMode,
                        oppmHNumEvents          Counter
                }

        oppmHMode       OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { oppmHistEntry 1 }

        oppmHNumEvents  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         OPPM's."
                ::= { oppmHistEntry 2 }

        oppmHHistTable  OBJECT-TYPE
                SYNTAX  SEQUENCE OF OppmHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each fadm card"
                ::= { oppmHist 2 }

        oppmHHistEntry  OBJECT-TYPE
                SYNTAX  OppmHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { oppmHHistMode, oppmHHistLocation, oppmHHistShelf,
                        oppmHHistSlot }
                ::= { oppmHHistTable 1 }

        OppmHHistEntry  ::=
                SEQUENCE
                {
                        oppmHHistMode           HistoryMode,
                        oppmHHistLocation       CardLocation,
                        oppmHHistShelf          CardShelf,
                        oppmHHistSlot           INTEGER,
                        oppmHLastBootTime       DateAndTime,
                        oppmHAvailTime          Counter,
                        oppmHErrFreeSecs        Counter
                }

        oppmHHistMode   OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { oppmHHistEntry 1 }

        oppmHHistLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card.  Choices are local or
                         remote."
                ::= { oppmHHistEntry 2 }

        oppmHHistShelf  OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 10"
                ::= { oppmHHistEntry 3 }

        oppmHHistSlot   OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { oppmHHistEntry 4 }

        oppmHLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this card."
                ::= { oppmHHistEntry 6 }

        oppmHAvailTime  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this Mux has been up and
                         running."
                ::= { oppmHHistEntry 7 }

        oppmHErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this mux has not
                         experienced any alarms."
                ::= { oppmHHistEntry 8 }

        -- The elements in the mcmHist subgroup of the historical subgroup

        mcmHistTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF McmHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for historical
                         data collected for the channel card"
                ::= { mcmHist 1 }

        mcmHistEntry    OBJECT-TYPE
                SYNTAX  McmHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { mcmHMode }
                ::= { mcmHistTable 1 }

        McmHistEntry    ::=
                SEQUENCE
                {
                        mcmHMode                HistoryMode,
                        mcmHNumEvents           Counter
                }

        mcmHMode        OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { mcmHistEntry 1 }

        mcmHNumEvents   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of events received for all mcmt1's/mcme1's"
                ::= { mcmHistEntry 2 }

        mcmHCntrTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF McmHCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entry for the software counters."
                ::= { mcmHist 2 }

        mcmHCntrEntry   OBJECT-TYPE
                SYNTAX  McmHCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { mcmHCntrMode, mcmHCntrLocation, mcmHCntrShelf,
                          mcmHCntrSlot, mcmHCntrType }
                ::= { mcmHCntrTable 1 }

        McmHCntrEntry   ::=
                SEQUENCE
                {
                        mcmHCntrMode            HistoryMode,
                        mcmHCntrLocation        CardLocation,
                        mcmHCntrShelf           CardShelf,
                        mcmHCntrSlot            INTEGER,
                        mcmHCntrType            INTEGER,
                        mcmHTotPktSent          Counter,
                        mcmHTotPktRcvd          Counter,
                        mcmHBadPktRcvd          Counter,
                        mcmHTotBadTrans         Counter,
                        mcmHBytesSent           Counter,
                        mcmHBytesRcvd           Counter,
                        mcmHMsgsDlvrd           Counter,
                        mcmHBufAllocFail        Counter,
                        mcmHEcbAllocFail        Counter
                }

        mcmHCntrMode    OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { mcmHCntrEntry 1 }

        mcmHCntrLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the mcm/mcme1 card.  The values are: Local
                         or Remote.  The system automatically determines the
                         right value for this entry based on the known
                         mcmt1/mcme1 cards."
                ::= { mcmHCntrEntry 2 }

        mcmHCntrShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 3.
                         The system automatically determines the right value
                         for this entry based on the known (available) mcmt1/mcme1
                         cards."
                ::= { mcmHCntrEntry 3 }

        mcmHCntrSlot    OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in. The
                         system automatically determines the right
                         value for this entry based on the known
                         (available) mcmt1/mcme1 cards."
                ::= { mcmHCntrEntry 4 }

        mcmHCntrType    OBJECT-TYPE
                SYNTAX  INTEGER { spi(1), iwm(2) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The type of the software counter data in this row.
                         The data is collected for the SPI data channels."
                ::= { mcmHCntrEntry 5 }

        mcmHTotPktSent  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets sent over the given data
                         channel."
                ::= { mcmHCntrEntry 6 }

        mcmHTotPktRcvd  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets received over the given
                         data channel."
                ::= { mcmHCntrEntry 7 }

        mcmHBadPktRcvd  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data packets received over the given
                         data channel."
                ::= { mcmHCntrEntry 8 }

        mcmHTotBadTrans OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data transmissions over the given
                         data channel."
                ::= { mcmHCntrEntry 9 }

        mcmHBytesSent   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of bytes sent over the given
                         data channel."
                ::= { mcmHCntrEntry 10 }

        mcmHBytesRcvd   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of data bytes received over the given
                         data channel."
                ::= { mcmHCntrEntry 11 }

        mcmHMsgsDlvrd   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of complete messages delivered over the
                         given data channel."
                ::= { mcmHCntrEntry 12 }

        mcmHBufAllocFail OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of buffer allocation failures for the given
                         data channel."
                ::= { mcmHCntrEntry 13 }

        mcmHEcbAllocFail OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of Event Control Block allocation failures
                         for the given data channel."
                ::= { mcmHCntrEntry 14 }

        --       port entries

        mcmPortHIntervalTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF McmPortHIntervalEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entry for the mcmt1/mcme1 port counters."
                ::= { mcmHist 3 }

        mcmPortHIntervalEntry OBJECT-TYPE
                SYNTAX  McmPortHIntervalEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { mcmPortHIntervalLocation, mcmPortHIntervalShelf,
                          mcmPortHIntervalSlot, mcmPortHIntervalPort,
                          mcmPortHIntervalNumber }
                ::= { mcmPortHIntervalTable 1 }

        McmPortHIntervalEntry ::=
                SEQUENCE
                {
                        mcmPortHIntervalLocation    CardLocation,
                        mcmPortHIntervalShelf       CardShelf,
                        mcmPortHIntervalSlot        INTEGER,
                        mcmPortHIntervalPort        INTEGER,
                        mcmPortHIntervalNumber      INTEGER,
                        mcmPortHIntervalASs         Counter,
                        mcmPortHIntervalFrameASs    Counter,
                        mcmPortHIntervalFEs         Counter,
                        mcmPortHIntervalCRCErrs     Counter,
                        mcmPortHIntervalSESs        Counter,
                        mcmPortHIntervalSEFSs       Counter,
                        mcmPortHIntervalUASs        Counter,
                        mcmPortHIntervalLESs        Counter,
                        mcmPortHIntervalBESs        Counter,
                        mcmPortHIntervalDMs         Counter,
                        mcmPortHIntervalLCVs        Counter
                }


        mcmPortHIntervalLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the mcm/mcme1 card.  The values are: Local
                         or Remote.  The system automatically determines the
                         right value for this entry based on the known
                         mcm/mcme1 cards."
                ::= { mcmPortHIntervalEntry 1 }

        mcmPortHIntervalShelf OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 3.
                         The system automatically determines the right value
                         for this entry based on the known (available) mcmt1/mcme1
                         cards."
                ::= { mcmPortHIntervalEntry 2 }

        mcmPortHIntervalSlot OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  The
                         system automatically determines the right value
                         for this entry based on the known (available)
                         mcmt1/mcme1 cards."
                ::= { mcmPortHIntervalEntry 3 }

        mcmPortHIntervalPort OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The port within the shelf the card is in.  Valid
                         values are: 1 to 4.  The system automatically
                         determines the right value for this entry based
                         on the known (available) mcmt1/mcme1 cards."
                ::= { mcmPortHIntervalEntry 4 }


        mcmPortHIntervalNumber OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The Interval number of the ds1 port.  Valid
                         values are: 1 to 96.  The system automatically
                         determines the right value for this entry based
                         on the known (available) interval number."
                ::= { mcmPortHIntervalEntry 5 }

        mcmPortHIntervalASs OBJECT-TYPE
                SYNTAX  Counter 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's ASs counter for specific interval."
                ::= { mcmPortHIntervalEntry 6 }

        mcmPortHIntervalFrameASs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's FrameASs counter for specific interval."
                ::= { mcmPortHIntervalEntry 7 }

        mcmPortHIntervalFEs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's FEs counter for specific interval." 
                ::= { mcmPortHIntervalEntry 8 }

        mcmPortHIntervalCRCErrs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's CRC errs counter for specific interval."
                ::= { mcmPortHIntervalEntry 9 }

        mcmPortHIntervalSESs OBJECT-TYPE
                SYNTAX  Counter 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's SESs counter less than 15 mins."
                ::= { mcmPortHIntervalEntry 10 }

        mcmPortHIntervalSEFSs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's SEFSs counter less than 15 mins."
                ::= { mcmPortHIntervalEntry 11 }

        mcmPortHIntervalUASs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's UASs counter less than 15 mins." 
                ::= { mcmPortHIntervalEntry 12 }

        mcmPortHIntervalLESs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's LESs counter less than 15 mins."
                ::= { mcmPortHIntervalEntry 13 }

        mcmPortHIntervalBESs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's BESs counter less than 15 mins."
                ::= { mcmPortHIntervalEntry 14 }

        mcmPortHIntervalDMs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's DMSs counter less than 15 mins."
                ::= { mcmPortHIntervalEntry 15 }

        mcmPortHIntervalLCVs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's LCVs counter less than 15 mins."
                ::= { mcmPortHIntervalEntry 16 }

        --  24 hr total port entries

        mcmPortHTotalTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF McmPortHTotalEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entry for the mcmt1/mcme1 port counters."
                ::= { mcmHist 4 }

        mcmPortHTotalEntry OBJECT-TYPE
                SYNTAX  McmPortHTotalEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { mcmPortHTotalLocation, mcmPortHTotalShelf,
                          mcmPortHTotalSlot, mcmPortHTotalPort }
                ::= { mcmPortHTotalTable 1 }

        McmPortHTotalEntry ::=
                SEQUENCE
                {
                        mcmPortHTotalLocation   CardLocation,
                        mcmPortHTotalShelf      CardShelf,
                        mcmPortHTotalSlot       INTEGER,
                        mcmPortHTotalPort       INTEGER,
                        mcmPortHTotalASs        Counter,
                        mcmPortHTotalFrameASs   Counter,
                        mcmPortHTotalFEs        Counter,
                        mcmPortHTotalCRCErrs    Counter,
                        mcmPortHTotalSESs       Counter,
                        mcmPortHTotalSEFSs      Counter,
                        mcmPortHTotalUASs       Counter,
                        mcmPortHTotalLESs       Counter,
                        mcmPortHTotalBESs       Counter,
                        mcmPortHTotalDMs        Counter,
                        mcmPortHTotalLCVs       Counter
                }


        mcmPortHTotalLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the mcm card.  The values are: Local
                         or Remote.  The system automatically determines the
                         right value for this entry based on the known
                         mcm/mcme1 cards."
                ::= { mcmPortHTotalEntry 1 }

        mcmPortHTotalShelf OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 3.
                         The system automatically determines the right value
                         for this entry based on the known (available) mcmt1/mcme1
                         cards."
                ::= { mcmPortHTotalEntry 2 }

        mcmPortHTotalSlot OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  The
                         system automatically determines the right
                         value for this entry based on the known
                         (available) mcmt1/mcme1 cards."
                ::= { mcmPortHTotalEntry 3 }



        mcmPortHTotalPort OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The port within the shelf the card is in.  Valid
                         values are: 1 to 4.  The system automatically
                         determines the right value for this entry based
                         on the known (available) mcmt1/mcme1 cards."
                ::= { mcmPortHTotalEntry 4 }

        mcmPortHTotalASs OBJECT-TYPE
                SYNTAX  Counter 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's ASs counter for the last 24 hrs."
                ::= { mcmPortHTotalEntry 5 }

        mcmPortHTotalFrameASs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's FrameASs counter for the last 24 hrs."
                ::= { mcmPortHTotalEntry 6 }

        mcmPortHTotalFEs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's FEs counter for the last 24 hrs." 
                ::= { mcmPortHTotalEntry 7 }

        mcmPortHTotalCRCErrs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's CRC errs counter for the last 24 hrs."
                ::= { mcmPortHTotalEntry 8 }

        mcmPortHTotalSESs OBJECT-TYPE
                SYNTAX  Counter 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's SESs counter less than 15 mins."
                ::= { mcmPortHTotalEntry 9 }

        mcmPortHTotalSEFSs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's SEFSs counter less than 15 mins."
                ::= { mcmPortHTotalEntry 10 }

        mcmPortHTotalUASs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's UASs counter less than 15 mins." 
                ::= { mcmPortHTotalEntry 11 }

        mcmPortHTotalLESs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's LESs counter less than 15 mins."
                ::= { mcmPortHTotalEntry 12 }

        mcmPortHTotalBESs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's BESs counter less than 15 mins."
                ::= { mcmPortHTotalEntry 13 }

        mcmPortHTotalDMs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's DMSs counter less than 15 mins."
                ::= { mcmPortHTotalEntry 14 }

        mcmPortHTotalLCVs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMT1/MCME1 port's LCVs counter less than 15 mins."
                ::= { mcmPortHTotalEntry 15 }

        -- The elements in the fnHist subgroup of the historical subgroup

        fnHistTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF FnHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for historical
                         data collected for the fan modules"
                ::= { fnHist 1 }

        fnHistEntry     OBJECT-TYPE
                SYNTAX  FnHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { fnHMode }
                ::= { fnHistTable 1 }

        FnHistEntry     ::=
                SEQUENCE
                {
                        fnHMode                 HistoryMode,
                        fnHNumEvents            Counter
                }

        fnHMode         OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  not-accessible 
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { fnHistEntry 1 }

        fnHNumEvents    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible 
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         fan modules."
                ::= { fnHistEntry 2 }

        -- The elements in the csimHist subgroup of the historical subgroup

        csimHistTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF CsimHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for historical
                         data collected for the ColorSIM "
                ::= { csimHist 1 }

        csimHistEntry   OBJECT-TYPE
                SYNTAX  CsimHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { csimHMode }
                ::= { csimHistTable 1 }

        CsimHistEntry   ::=
                SEQUENCE
                {
                        csimHMode               HistoryMode,
                        csimHNumEvents          Counter
                }

        csimHMode       OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm. The reason this has been made obsolete
                         is that all colorsim related events would eventually be part
                         of ocm events"
                ::= { csimHistEntry 1 }

        csimHNumEvents  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This variable keeps track of the number of events
                         related to ColorSIM. The reason this has been made obsolete
                         is that all colorsim related events would eventually be part
                         of ocm events"
                ::= { csimHistEntry 2 }
     
        csimHistIntervalTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF CsimHistIntervalEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         colorsim card."
                ::= { csimHist 2 }

        csimHistIntervalEntry OBJECT-TYPE
                SYNTAX  CsimHistIntervalEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { csimIntervalLocation, csimIntervalShelf,
                          csimIntervalSlot, csimIntervalNumber }
                ::= { csimHistIntervalTable 1 }

        CsimHistIntervalEntry ::=
                SEQUENCE
                {
                        csimIntervalLocation    CardLocation,
                        csimIntervalShelf       CardShelf,
                        csimIntervalSlot        INTEGER,
                        csimIntervalNumber      INTEGER,
                        csimIntervalEFIs        INTEGER,
                        csimIntervalEIs         INTEGER,
                        csimIntervalSEIs        INTEGER,
                        csimIntervalBERs        DisplayString,
                        csimIntervalUAIs        INTEGER,
                        csimIntervalValidData   Boolean,
                        csimIntervalDateTime    INTEGER
                }
    
        csimIntervalLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        " Location of the ColorSIM module"
                ::= { csimHistIntervalEntry 1 }

        csimIntervalShelf OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf of the ColorSIM module"
                ::= { csimHistIntervalEntry 2 }

        csimIntervalSlot OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The Slot of the ColorSIM module"
                ::= { csimHistIntervalEntry 3 }

        csimIntervalNumber OBJECT-TYPE
                SYNTAX  INTEGER (1..96)
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "This variable indicates the interval for which
                         the set of statistics data is available."
                ::= { csimHistIntervalEntry 4 }

        csimIntervalEFIs OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The counter associated with the number of Error Free
                         Interval Counts in this interval."
                ::= { csimHistIntervalEntry 5 }

        csimIntervalEIs OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The counter associated with the number of Errored
                         Interval Counts in this interval."
                ::= { csimHistIntervalEntry 6 }

        csimIntervalSEIs OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The counter associated with the number of Severely
                         Errored Interval Counts in this interval."
                ::= { csimHistIntervalEntry 7 }

        csimIntervalBERs OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The counter associated with the number of Bit
                         Error Rate Counts in this interval.  The unit
                         is in the form of x.ye-z."
                ::= { csimHistIntervalEntry 8 }

        csimIntervalUAIs OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The counter associated with the number of Unavailable
                         Interval Counts in this interval."
                ::= { csimHistIntervalEntry 9 }

        csimIntervalValidData OBJECT-TYPE
                SYNTAX  Boolean
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This variable indicates if the data for this interval
                         is valid. Not supported"
                ::= { csimHistIntervalEntry 10 }

        csimIntervalDateTime OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Time in seconds elasped since 01/01/1970 00:00:00 GMT for this interval. 
                         Assuming local time is same as GMT" 
                ::= { csimHistIntervalEntry 11 }

        -- The elements in the rpsmHist subgroup of the historical subgroup

        rpsmHistTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF RpsmHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for historical
                         data collected for the rpsm card"
                ::= { rpsmHist 1 }

        rpsmHistEntry   OBJECT-TYPE
                SYNTAX  RpsmHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { oppmHMode }
                ::= { rpsmHistTable 1 }

        RpsmHistEntry    ::=
                SEQUENCE
                {
                        rpsmHMode        HistoryMode,
                        rpsmHNumEvents   Counter
                }

        rpsmHMode       OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { rpsmHistEntry 1 }

        rpsmHNumEvents  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         RPSM's."
                ::= { rpsmHistEntry 2 }

        rpsmHHistTable  OBJECT-TYPE
                SYNTAX  SEQUENCE OF RpsmHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each rpsm card"
                ::= { rpsmHist 2 }

        rpsmHHistEntry  OBJECT-TYPE
                SYNTAX  RpsmHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { rpsmHHistMode, rpsmHHistLocation, rpsmHHistShelf,
                        rpsmHHistSlot }
                ::= { rpsmHHistTable 1 }

        RpsmHHistEntry   ::=
                SEQUENCE
                {
                        rpsmHHistMode      HistoryMode,
                        rpsmHHistLocation  CardLocation,
                        rpsmHHistShelf     CardShelf,
                        rpsmHHistSlot      INTEGER,
                        rpsmHLastBootTime  DateAndTime,
                        rpsmHAvailTime     Counter,
                        rpsmHErrFreeSecs   Counter
                }

        rpsmHHistMode   OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { rpsmHHistEntry 1 }

        rpsmHHistLocation  OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card.  Choices are local or
                         remote."
                ::= { rpsmHHistEntry 2 }

        rpsmHHistShelf  OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 10"
                ::= { rpsmHHistEntry 3 }

        rpsmHHistSlot   OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { rpsmHHistEntry 4 }

        rpsmHLastBootTime  OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this card."
                ::= { rpsmHHistEntry 6 }

        rpsmHAvailTime  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this rpsm has been up and
                         running."
                ::= { rpsmHHistEntry 7 }

        rpsmHErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this rpsm has not
                         experienced any alarms."
                ::= { rpsmHHistEntry 8 }

        -- The elements in the rsdmHist subgroup of the historical subgroup

        rsdmHistTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF RsdmHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for historical
                         data collected for the rsdm card"
                ::= { rsdmHist 1 }

        rsdmHistEntry   OBJECT-TYPE
                SYNTAX  RsdmHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { rsdmHMode }
                ::= { rsdmHistTable 1 }

        RsdmHistEntry    ::=
                SEQUENCE
                {
                        rsdmHMode        HistoryMode,
                        rsdmHNumEvents   Counter
                }

        rsdmHMode       OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { rsdmHistEntry 1 }

        rsdmHNumEvents  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         RSDM's."
                ::= { rsdmHistEntry 2 }

        rsdmHHistTable  OBJECT-TYPE
                SYNTAX  SEQUENCE OF RsdmHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each rsdm card."
                ::= { rsdmHist 2 }

        rsdmHHistEntry  OBJECT-TYPE
                SYNTAX  RsdmHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { rsdmHHistMode, rsdmHHistLocation, rsdmHHistShelf,
                        rsdmHHistSlot }
                ::= {rsdmHHistTable 1 }

        RsdmHHistEntry   ::=
                SEQUENCE
                {
                        rsdmHHistMode      HistoryMode,
                        rsdmHHistLocation  CardLocation,
                        rsdmHHistShelf     CardShelf,
                        rsdmHHistSlot      INTEGER,
                        rsdmHLastBootTime  DateAndTime,
                        rsdmHAvailTime     Counter,
                        rsdmHErrFreeSecs   Counter
                }

        rsdmHHistMode   OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { rsdmHHistEntry 1 }

        rsdmHHistLocation  OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card.  Choices are local or
                         remote."
                ::= { rsdmHHistEntry 2 }

        rsdmHHistShelf  OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 10"
                ::= { rsdmHHistEntry 3 }

        rsdmHHistSlot   OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { rsdmHHistEntry 4 }

        rsdmHLastBootTime  OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this card."
                ::= { rsdmHHistEntry 6 }

        rsdmHAvailTime  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this rsdm has been up and
                         running."
                ::= { rsdmHHistEntry 7 }

        rsdmHErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this rsdm has not
                         experienced any alarms."
                ::= { rsdmHHistEntry 8 }

        -- The elements in the rtdmHist subgroup of the historical subgroup

        rtdmHistTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF RtdmHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for historical
                         data collected for the rtdm card"
                ::= { rtdmHist 1 }

        rtdmHistEntry   OBJECT-TYPE
                SYNTAX  RtdmHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { rtdmHMode }
                ::= { rtdmHistTable 1 }

        RtdmHistEntry    ::=
                SEQUENCE
                {
                        rtdmHMode        HistoryMode,
                        rtdmHNumEvents   Counter
                }

        rtdmHMode       OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { rtdmHistEntry 1 }

        rtdmHNumEvents  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         rtdm's."
                ::= { rtdmHistEntry 2 }

        rtdmHHistTable  OBJECT-TYPE
                SYNTAX  SEQUENCE OF RtdmHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each rtdm card."
                ::= { rtdmHist 2 }

        rtdmHHistEntry  OBJECT-TYPE
                SYNTAX  RtdmHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { rtdmHHistMode, rtdmHHistLocation, rtdmHHistShelf,
                        rtdmHHistSlot }
                ::= { rtdmHHistTable 1 }

        RtdmHHistEntry   ::=
                SEQUENCE
                {
                        rtdmHHistMode      HistoryMode,
                        rtdmHHistLocation  CardLocation,
                        rtdmHHistShelf     CardShelf,
                        rtdmHHistSlot      INTEGER,
                        rtdmHLastBootTime  DateAndTime,
                        rtdmHAvailTime     Counter,
                        rtdmHErrFreeSecs   Counter
                }

        rtdmHHistMode   OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { rtdmHHistEntry 1 }

        rtdmHHistLocation  OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card.  Choices are local or
                         remote."
                ::= { rtdmHHistEntry 2 }

        rtdmHHistShelf  OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 10"
                ::= { rtdmHHistEntry 3 }

        rtdmHHistSlot   OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { rtdmHHistEntry 4 }

        rtdmHLastBootTime  OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this card."
                ::= { rtdmHHistEntry 5 }

       rtdmHAvailTime   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this rtdm has been up and
                         running."
                ::= { rtdmHHistEntry 6 }

       rtdmHErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this rtdm has not
                         experienced any alarms."
                ::= { rtdmHHistEntry 7 }

        -- The elements in the osamHist subgroup of the historical subgroup

        osamHistTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF OsamHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for historical
                         data collected for the osam module."
                ::= { osamHist 1 }

        osamHistEntry    OBJECT-TYPE
                SYNTAX  OsamHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { osamHMode }
                ::= { osamHistTable 1 }

        OsamHistEntry   ::=
                SEQUENCE
                {
                        osamHMode               HistoryMode,
                        osamHNumEvents          Counter
                }

        osamHMode       OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of data collection."
                ::= { osamHistEntry 1 }

        osamHNumEvents  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of events received for all osam's."
                ::= { osamHistEntry 2 }

        osamHHistTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF OsamHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for 
                         historical performance data collected for each 
                         osam module."
                ::= { osamHist 2 }

        osamHHistEntry   OBJECT-TYPE
                SYNTAX  OsamHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { osamHHistMode, osamHHistLocation, osamHHistShelf,
                          osamHHistSlot }
                ::= { osamHHistTable 1 }

        OsamHHistEntry  ::=
                SEQUENCE
                {
                        osamHHistMode           HistoryMode,
                        osamHHistLocation       CardLocation,
                        osamHHistShelf          CardShelf,
                        osamHHistSlot           INTEGER,
                        osamHHistLastBootTime   DateAndTime,
                        osamHHistAvailTime      Counter,
                        osamHHistErrFreeSecs    Counter
                }

        osamHHistMode   OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection."
                ::= { osamHHistEntry 1 }

        osamHHistLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Location of the module."
                ::= { osamHHistEntry 2 }

        osamHHistShelf  OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf number in which the module is plugged in."
                ::= { osamHHistEntry 3 }

        osamHHistSlot   OBJECT-TYPE
                SYNTAX  INTEGER (1..16)
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot number  in which the module is plugged in."
                ::= { osamHHistEntry 4 }

        osamHHistLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this module."
                ::= { osamHHistEntry 5 }

        osamHHistAvailTime OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds since the start of this 
                         historical mode that this module has been up and
                         running."
                ::= { osamHHistEntry 6 }

        osamHHistErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds since the start of this 
                         historical mode that this module has not experienced
                         any alarms."
                ::= { osamHHistEntry 7 }

        -- The elements in the rsmHist subgroup of the historical subgroup

        rsmHistTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF RsmHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for historical
                         data collected for the rsm card"
                ::= { rsmHist 1 }

        rsmHistEntry    OBJECT-TYPE
                SYNTAX  RsmHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { rsmHMode }
                ::= { rsmHistTable 1 }

        RsmHistEntry    ::=
                SEQUENCE
                {
                        rsmHMode                HistoryMode,
                        rsmHNumEvents           Counter
                }

        rsmHMode        OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { rsmHistEntry 1 }

        rsmHNumEvents   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         RSM's."
                ::= { rsmHistEntry 2 }

        rsmHHistTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF RsmHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each rsm card."
                ::= { rsmHist 2 }

        rsmHHistEntry   OBJECT-TYPE
                SYNTAX  RsmHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { rsmHHistMode, rsmHHistLocation, rsmHHistShelf,
                          rsmHHistSlot }
                ::= {rsmHHistTable 1 }

        RsmHHistEntry   ::=
                SEQUENCE
                {
                        rsmHHistMode            HistoryMode,
                        rsmHHistLocation        CardLocation,
                        rsmHHistShelf           CardShelf,
                        rsmHHistSlot            CardSlot,
                        rsmHLastBootTime        DateAndTime,
                        rsmHAvailTime           Counter,
                        rsmHErrFreeSecs         Counter
                }

        rsmHHistMode    OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { rsmHHistEntry 1 }

        rsmHHistLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card."
                ::= { rsmHHistEntry 2 }

        rsmHHistShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in."
                ::= { rsmHHistEntry 3 }

        rsmHHistSlot    OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { rsmHHistEntry 4 }

        rsmHLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this card."
                ::= { rsmHHistEntry 6 }

        rsmHAvailTime   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this rsm has been up and
                         running."
                ::= { rsmHHistEntry 7 }

        rsmHErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this rsm has not
                         experienced any alarms."
                ::= { rsmHHistEntry 8 }

        -- The elements in the upsmHist subgroup of the historical subgroup

        upsmHistTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF UpsmHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for historical
                         data collected for the upsm card"
                ::= { upsmHist 1 }

        upsmHistEntry   OBJECT-TYPE
                SYNTAX  UpsmHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { upsmHMode }
                ::= { upsmHistTable 1 }

        UpsmHistEntry   ::=
                SEQUENCE
                {
                        upsmHMode               HistoryMode,
                        upsmHNumEvents          Counter
                }

        upsmHMode       OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { upsmHistEntry 1 }

        upsmHNumEvents  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         UPSM's."
                ::= { upsmHistEntry 2 }

        upsmHHistTable  OBJECT-TYPE
                SYNTAX  SEQUENCE OF UpsmHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each upsm card."
                ::= { upsmHist 2 }

        upsmHHistEntry  OBJECT-TYPE
                SYNTAX  UpsmHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { upsmHHistMode, upsmHHistLocation, upsmHHistShelf,
                          upsmHHistSlot }
                ::= {upsmHHistTable 1 }

        UpsmHHistEntry  ::=
                SEQUENCE
                {
                        upsmHHistMode           HistoryMode,
                        upsmHHistLocation       CardLocation,
                        upsmHHistShelf          CardShelf,
                        upsmHHistSlot           CardSlot,
                        upsmHLastBootTime       DateAndTime,
                        upsmHAvailTime          Counter,
                        upsmHErrFreeSecs        Counter
                }

        upsmHHistMode   OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { upsmHHistEntry 1 }

        upsmHHistLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card."
                ::= { upsmHHistEntry 2 }

        upsmHHistShelf  OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in."
                ::= { upsmHHistEntry 3 }

        upsmHHistSlot   OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { upsmHHistEntry 4 }

        upsmHLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this card."
                ::= { upsmHHistEntry 6 }

        upsmHAvailTime  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this upsm has been up and
                         running."
                ::= { upsmHHistEntry 7 }

        upsmHErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this upsm has not
                         experienced any alarms."
                ::= { upsmHHistEntry 8 }

        -- The elements in the mcmescHist subgroup of the historical subgroup

        mcmescHistTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF McmescHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for historical
                         data collected for the channel card"
                ::= { mcmescHist 1 }

        mcmescHistEntry OBJECT-TYPE
                SYNTAX  McmescHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { mcmescHMode }
                ::= { mcmescHistTable 1 }

        McmescHistEntry ::=
                SEQUENCE
                {
                        mcmescHMode             HistoryMode,
                        mcmescHNumEvents        Counter
                }

        mcmescHMode     OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or long term."
                ::= { mcmescHistEntry 1 }

        mcmescHNumEvents OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of events received for all mcmesc's"
                ::= { mcmescHistEntry 2 }

        mcmescHCntrTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF McmescHCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entry for the software counters."
                ::= { mcmescHist 2 }

        mcmescHCntrEntry OBJECT-TYPE
                SYNTAX  McmescHCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { mcmescHCntrMode, mcmescHCntrLocation, mcmescHCntrShelf,
                          mcmescHCntrSlot, mcmescHCntrType }
                ::= { mcmescHCntrTable 1 }

        McmescHCntrEntry ::=
                SEQUENCE
                {
                        mcmescHCntrMode         HistoryMode,
                        mcmescHCntrLocation     CardLocation,
                        mcmescHCntrShelf        CardShelf,
                        mcmescHCntrSlot         INTEGER,
                        mcmescHCntrType         INTEGER,
                        mcmescHTotPktSent       Counter,
                        mcmescHTotPktRcvd       Counter,
                        mcmescHBadPktRcvd       Counter,
                        mcmescHTotBadTrans      Counter,
                        mcmescHBytesSent        Counter,
                        mcmescHBytesRcvd        Counter,
                        mcmescHMsgsDlvrd        Counter
                }

        mcmescHCntrMode OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or long term."
                ::= { mcmescHCntrEntry 1 }

        mcmescHCntrLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the mcmesc card.  The values are: Local
                         or Remote.  The system automatically determines the
                         right value for this entry based on the known
                         mcmesc cards."
                ::= { mcmescHCntrEntry 2 }

        mcmescHCntrShelf OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2.
                         The system automatically determines the right value
                         for this entry based on the known (available) mcmesc
                         cards."
                ::= { mcmescHCntrEntry 3 }

        mcmescHCntrSlot OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in. The
                         system automatically determines the right
                         value for this entry based on the known
                         (available) mcmesc cards."
                ::= { mcmescHCntrEntry 4 }

        mcmescHCntrType OBJECT-TYPE
                SYNTAX  INTEGER { spi(1), iwm(2) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The type of the software counter data in this row.
                         The data is collected for the SPI data channels."
                ::= { mcmescHCntrEntry 5 }

        mcmescHTotPktSent OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets sent over the given data
                         channel."
                ::= { mcmescHCntrEntry 6 }

        mcmescHTotPktRcvd OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets received over the given
                         data channel."
                ::= { mcmescHCntrEntry 7 }

        mcmescHBadPktRcvd OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data packets received over the given
                         data channel."
                ::= { mcmescHCntrEntry 8 }

        mcmescHTotBadTrans OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data transmissions over the given
                         data channel."
                ::= { mcmescHCntrEntry 9 }

        mcmescHBytesSent OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of bytes sent over the given
                         data channel."
                ::= { mcmescHCntrEntry 10 }

        mcmescHBytesRcvd OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of data bytes received over the given
                         data channel."
                ::= { mcmescHCntrEntry 11 }

        mcmescHMsgsDlvrd OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of complete messages delivered over the
                         given data channel."
                ::= { mcmescHCntrEntry 12 }

        -- The elements in the tapHist subgroup of the historical subgroup

        tapHistTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF TapHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for historical
                         data collected for the TAP module."
                ::= { tapHist 1 }

        tapHistEntry    OBJECT-TYPE
                SYNTAX  TapHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { tapHMode }
                ::= { tapHistTable 1 }

        TapHistEntry    ::=
                SEQUENCE
                {
                        tapHMode                HistoryMode,
                        tapHNumEvents           Counter
                }

        tapHMode        OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { tapHistEntry 1 }

        tapHNumEvents   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         TAP modules."
                ::= { tapHistEntry 2 }

        tapHHistTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF TapHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each TAP module"
                ::= { tapHist 2 }

        tapHHistEntry   OBJECT-TYPE
                SYNTAX  TapHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { tapHHistMode, tapHHistLocation, tapHHistShelf,
                          tapHHistSlot }
                ::= { tapHHistTable 1 }

        TapHHistEntry   ::=
                SEQUENCE
                {
                        tapHHistMode            HistoryMode,
                        tapHHistLocation        CardLocation,
                        tapHHistShelf           CardShelf,
                        tapHHistSlot            INTEGER,
                        tapHHistType            INTEGER,
                        tapHLastBootTime        DateAndTime,
                        tapHAvailTime           Counter,
                        tapHErrFreeSecs         Counter
                }

        tapHHistMode    OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { tapHHistEntry 1 }

        tapHHistLocation  OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the module.  Choices are local or remote."
                ::= { tapHHistEntry 2 }

        tapHHistShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the module is in."
                ::= { tapHHistEntry 3 }

        tapHHistSlot    OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the module is in."
                ::= { tapHHistEntry 4 }

        tapHHistType    OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module type."
                ::= { tapHHistEntry 5 }

        tapHLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this module."
                ::= { tapHHistEntry 6 }

        tapHAvailTime   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this module has been up and
                         running."
                ::= { tapHHistEntry 7 }

        tapHErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this module has not
                         experienced any alarms."
                ::= { tapHHistEntry 8 }

        -- The elements in the voadmHist subgroup of the historical subgroup

        voadmHistTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF VoadmHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for historical
                         data collected for the VOADM module."
                ::= { voadmHist 1 }

        voadmHistEntry    OBJECT-TYPE
                SYNTAX  VoadmHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { voadmHMode }
                ::= { voadmHistTable 1 }

        VoadmHistEntry    ::=
                SEQUENCE
                {
                        voadmHMode                HistoryMode,
                        voadmHNumEvents           Counter
                }

        voadmHMode        OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { voadmHistEntry 1 }

        voadmHNumEvents   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         VOADM modules."
                ::= { voadmHistEntry 2 }

        voadmHHistTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF VoadmHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each VOADM module"
                ::= { voadmHist 2 }

        voadmHHistEntry   OBJECT-TYPE
                SYNTAX  VoadmHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { voadmHHistMode, voadmHHistLocation, voadmHHistShelf,
                          voadmHHistSlot }
                ::= { voadmHHistTable 1 }

        VoadmHHistEntry   ::=
                SEQUENCE
                {
                        voadmHHistMode            HistoryMode,
                        voadmHHistLocation        CardLocation,
                        voadmHHistShelf           CardShelf,
                        voadmHHistSlot            INTEGER,
                        voadmHHistType            INTEGER,
                        voadmHLastBootTime        DateAndTime,
                        voadmHAvailTime           Counter,
                        voadmHErrFreeSecs         Counter
                }

        voadmHHistMode    OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { voadmHHistEntry 1 }

        voadmHHistLocation  OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the module.  Choices are local or remote."
                ::= { voadmHHistEntry 2 }

        voadmHHistShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the module is in."
                ::= { voadmHHistEntry 3 }

        voadmHHistSlot    OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the module is in."
                ::= { voadmHHistEntry 4 }

        voadmHHistType    OBJECT-TYPE
                SYNTAX  CardType
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Module type."
                ::= { voadmHHistEntry 5 }

        voadmHLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this module."
                ::= { voadmHHistEntry 6 }

        voadmHAvailTime   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this module has been up and
                         running."
                ::= { voadmHHistEntry 7 }

        voadmHErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this module has not
                         experienced any alarms."
                ::= { voadmHHistEntry 8 }

        -- The elements in the dmmHist subgroup of the historical subgroup

        dmmHistTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF DmmHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for historical
                         data collected for the DMM module."
                ::= { dmmHist 1 }

        dmmHistEntry    OBJECT-TYPE
                SYNTAX  DmmHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { dmmHMode }
                ::= { dmmHistTable 1 }

        DmmHistEntry    ::=
                SEQUENCE
                {
                        dmmHMode                HistoryMode,
                        dmmHNumEvents           Counter
                }

        dmmHMode        OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { dmmHistEntry 1 }

        dmmHNumEvents   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         DMM modules."
                ::= { dmmHistEntry 2 }

        dmmHHistTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF DmmHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each DMM module"
                ::= { dmmHist 2 }

        dmmHHistEntry   OBJECT-TYPE
                SYNTAX  DmmHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { dmmHHistMode, dmmHHistLocation, dmmHHistShelf,
                          dmmHHistSlot }
                ::= { dmmHHistTable 1 }

        DmmHHistEntry   ::=
                SEQUENCE
                {
                        dmmHHistMode            HistoryMode,
                        dmmHHistLocation        CardLocation,
                        dmmHHistShelf           CardShelf,
                        dmmHHistSlot            INTEGER,
                        dmmHLastBootTime        DateAndTime,
                        dmmHAvailTime           Counter,
                        dmmHErrFreeSecs         Counter
                }

        dmmHHistMode    OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { dmmHHistEntry 1 }

        dmmHHistLocation    OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the module.  Choices are local or remote."
                ::= { dmmHHistEntry 2 }

        dmmHHistShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the module is in."
                ::= { dmmHHistEntry 3 }

        dmmHHistSlot    OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the module is in."
                ::= { dmmHHistEntry 4 }

        dmmHLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this module."
                ::= { dmmHHistEntry 5 }

        dmmHAvailTime   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this module has been up and
                         running."
                ::= { dmmHHistEntry 6 }

        dmmHErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this module has not
                         experienced any alarms."
                ::= { dmmHHistEntry 7 }

        -- The elements in the ocm10gfHist subgroup of the historical subgroup

        ocm10gfHistTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF Ocm10gfHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for historical
                         data collected for the OCM10GF module."
                ::= { ocm10gfHist 1 }

        ocm10gfHistEntry    OBJECT-TYPE
                SYNTAX  Ocm10gfHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { ocm10gfHMode }
                ::= { ocm10gfHistTable 1 }

        Ocm10gfHistEntry    ::=
                SEQUENCE
                {
                        ocm10gfHMode                HistoryMode,
                        ocm10gfHNumEvents           Counter
                }

        ocm10gfHMode        OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { ocm10gfHistEntry 1 }

        ocm10gfHNumEvents   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         OCM10GF modules."
                ::= { ocm10gfHistEntry 2 }

        ocm10gfHHistTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF Ocm10gfHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each OCM10GF module"
                ::= { ocm10gfHist 2 }

        ocm10gfHHistEntry   OBJECT-TYPE
                SYNTAX  Ocm10gfHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { ocm10gfHHistMode, ocm10gfHHistLocation, ocm10gfHHistShelf,
                          ocm10gfHHistSlot }
                ::= { ocm10gfHHistTable 1 }

        Ocm10gfHHistEntry   ::=
                SEQUENCE
                {
                        ocm10gfHHistMode            HistoryMode,
                        ocm10gfHHistLocation        CardLocation,
                        ocm10gfHHistShelf           CardShelf,
                        ocm10gfHHistSlot            INTEGER,
                        ocm10gfHLastBootTime        DateAndTime,
                        ocm10gfHAvailTime           Counter,
                        ocm10gfHErrFreeSecs         Counter
                }

        ocm10gfHHistMode    OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { ocm10gfHHistEntry 1 }

        ocm10gfHHistLocation    OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the module.  Choices are local or remote."
                ::= { ocm10gfHHistEntry 2 }

        ocm10gfHHistShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the module is in."
                ::= { ocm10gfHHistEntry 3 }

        ocm10gfHHistSlot    OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the module is in."
                ::= { ocm10gfHHistEntry 4 }

        ocm10gfHLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this module."
                ::= { ocm10gfHHistEntry 5 }

        ocm10gfHAvailTime   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this module has been up and
                         running."
                ::= { ocm10gfHHistEntry 6 }

        ocm10gfHErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this module has not
                         experienced any alarms."
                ::= { ocm10gfHHistEntry 7 }

        -- The elements in the ocm2Hist subgroup of the historical subgroup

        ocm2HistTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF Ocm2HistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for historical
                         data collected for the OCM2 module."
                ::= { ocm2Hist 1 }

        ocm2HistEntry    OBJECT-TYPE
                SYNTAX  Ocm2HistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { ocm2HMode }
                ::= { ocm2HistTable 1 }

        Ocm2HistEntry    ::=
                SEQUENCE
                {
                        ocm2HMode                HistoryMode,
                        ocm2HNumEvents           Counter
                }

        ocm2HMode        OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { ocm2HistEntry 1 }

        ocm2HNumEvents   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         OCM2 modules."
                ::= { ocm2HistEntry 2 }

        ocm2HHistTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF Ocm2HHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each OCM2 module"
                ::= { ocm2Hist 2 }

        ocm2HHistEntry   OBJECT-TYPE
                SYNTAX  Ocm2HHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { ocm2HHistMode, ocm2HHistLocation, ocm2HHistShelf,
                          ocm2HHistSlot }
                ::= { ocm2HHistTable 1 }

        Ocm2HHistEntry   ::=
                SEQUENCE
                {
                        ocm2HHistMode            HistoryMode,
                        ocm2HHistLocation        CardLocation,
                        ocm2HHistShelf           CardShelf,
                        ocm2HHistSlot            INTEGER,
                        ocm2HLastBootTime        DateAndTime,
                        ocm2HAvailTime           Counter,
                        ocm2HErrFreeSecs         Counter
                }

        ocm2HHistMode    OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { ocm2HHistEntry 1 }

        ocm2HHistLocation    OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the module.  Choices are local or remote."
                ::= { ocm2HHistEntry 2 }

        ocm2HHistShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the module is in."
                ::= { ocm2HHistEntry 3 }

        ocm2HHistSlot    OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the module is in."
                ::= { ocm2HHistEntry 4 }

        ocm2HLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this module."
                ::= { ocm2HHistEntry 5 }

        ocm2HAvailTime   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this module has been up and
                         running."
                ::= { ocm2HHistEntry 6 }

        ocm2HErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this module has not
                         experienced any alarms."
                ::= { ocm2HHistEntry 7 }

        -- The elements in the oscHist subgroup of the historical subgroup

        oscHistTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF OscHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for historical
                         data collected for the OSC module."
                ::= { oscHist 1 }

        oscHistEntry    OBJECT-TYPE
                SYNTAX  OscHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { oscHMode }
                ::= { oscHistTable 1 }

        OscHistEntry    ::=
                SEQUENCE
                {
                        oscHMode                HistoryMode,
                        oscHNumEvents           Counter
                }

        oscHMode        OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { oscHistEntry 1 }

        oscHNumEvents   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         OSC modules."
                ::= { oscHistEntry 2 }

        oscHHistTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF OscHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each OSC module"
                ::= { oscHist 2 }

        oscHHistEntry   OBJECT-TYPE
                SYNTAX  OscHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { oscHHistMode, oscHHistLocation, oscHHistShelf,
                          oscHHistSlot }
                ::= { oscHHistTable 1 }

        OscHHistEntry   ::=
                SEQUENCE
                {
                        oscHHistMode            HistoryMode,
                        oscHHistLocation        CardLocation,
                        oscHHistShelf           CardShelf,
                        oscHHistSlot            INTEGER,
                        oscHLastBootTime        DateAndTime,
                        oscHAvailTime           Counter,
                        oscHErrFreeSecs         Counter
                }

        oscHHistMode    OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { oscHHistEntry 1 }

        oscHHistLocation    OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the module.  Choices are local or remote."
                ::= { oscHHistEntry 2 }

        oscHHistShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the module is in."
                ::= { oscHHistEntry 3 }

        oscHHistSlot    OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the module is in."
                ::= { oscHHistEntry 4 }

        oscHLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this module."
                ::= { oscHHistEntry 5 }

        oscHAvailTime   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this module has been up and
                         running."
                ::= { oscHHistEntry 6 }

        oscHErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this module has not
                         experienced any alarms."
                ::= { oscHHistEntry 7 }

        -- The elements in the ocm4gHist subgroup of the historical subgroup

        ocm4gHistTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF Ocm4gHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for historical
                         data collected for the OCM4G module."
                ::= { ocm4gHist 1 }

        ocm4gHistEntry    OBJECT-TYPE
                SYNTAX  Ocm4gHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { ocm4gHMode }
                ::= { ocm4gHistTable 1 }

        Ocm4gHistEntry    ::=
                SEQUENCE
                {
                        ocm4gHMode                HistoryMode,
                        ocm4gHNumEvents           Counter
                }

        ocm4gHMode        OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { ocm4gHistEntry 1 }

        ocm4gHNumEvents   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         OCM4G modules."
                ::= { ocm4gHistEntry 2 }

        ocm4gHHistTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF Ocm4gHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each OCM4G module"
                ::= { ocm4gHist 2 }

        ocm4gHHistEntry   OBJECT-TYPE
                SYNTAX  Ocm4gHHistEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { ocm4gHHistMode, ocm4gHHistLocation, ocm4gHHistShelf,
                          ocm4gHHistSlot }
                ::= { ocm4gHHistTable 1 }

        Ocm4gHHistEntry   ::=
                SEQUENCE
                {
                        ocm4gHHistMode            HistoryMode,
                        ocm4gHHistLocation        INTEGER,
                        ocm4gHHistShelf           CardShelf,
                        ocm4gHHistSlot            INTEGER,
                        ocm4gHLastBootTime        DateAndTime,
                        ocm4gHAvailTime           Counter,
                        ocm4gHErrFreeSecs         Counter
                }

        ocm4gHHistMode    OBJECT-TYPE
                SYNTAX  HistoryMode
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The mode of the data collection.  Valid values are:
                         daily or longterm."
                ::= { ocm4gHHistEntry 1 }

        ocm4gHHistLocation    OBJECT-TYPE
                SYNTAX  INTEGER { local(1) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the module.  Choices are local or remote."
                ::= { ocm4gHHistEntry 2 }

        ocm4gHHistShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the module is in."
                ::= { ocm4gHHistEntry 3 }

        ocm4gHHistSlot    OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the module is in."
                ::= { ocm4gHHistEntry 4 }

        ocm4gHLastBootTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the last boot for this module."
                ::= { ocm4gHHistEntry 5 }

        ocm4gHAvailTime   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this module has been up and
                         running."
                ::= { ocm4gHHistEntry 6 }

        ocm4gHErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds that this module has not
                         experienced any alarms."
                ::= { ocm4gHHistEntry 7 }

        -- The elements in the oscHist subgroup of the historical subgroup
        --     CPE port 96 interval entries

        mcmescPortHIntervalTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF McmescPortHIntervalEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entry for the mcmesc port counters."
                ::= { mcmescHist 3 }

        mcmescPortHIntervalEntry OBJECT-TYPE
                SYNTAX  McmescPortHIntervalEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { mcmescPortHIntervalLocation, mcmescPortHIntervalShelf,
                          mcmescPortHIntervalSlot, mcmescPortHIntervalPort,
                          mcmescPortHIntervalNumber }
                ::= { mcmescPortHIntervalTable 1 }

        McmescPortHIntervalEntry ::=
                SEQUENCE 
                {
                        mcmescPortHIntervalLocation CardLocation,
                        mcmescPortHIntervalShelf    CardShelf,
                        mcmescPortHIntervalSlot     INTEGER,
                        mcmescPortHIntervalPort     INTEGER,
                        mcmescPortHIntervalNumber   INTEGER,
                        mcmescPortHIntervalDuration DisplayString,
                        mcmescPortHIntervalEns      DisplayString,
                        mcmescPortHIntervalLoss     DisplayString,
                        mcmescPortHIntervalCrcErr   DisplayString,
                        mcmescPortHIntervalOobErr   DisplayString,
                        mcmescPortHIntervalRdpErr   DisplayString
                }


        mcmescPortHIntervalLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the mcmesc card.  The values are: Local
                         or Remote.  The system automatically determines the
                         right value for this entry based on the known
                         mcmesc cards."
                ::= { mcmescPortHIntervalEntry 1 }

        mcmescPortHIntervalShelf OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 3.
                         The system automatically determines the right value
                         for this entry based on the known (available) mcmesc
                         cards."
                ::= { mcmescPortHIntervalEntry 2 }

        mcmescPortHIntervalSlot OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  The
                         system automatically determines the right value
                         for this entry based on the known (available)
                         mcmesc cards."
                ::= { mcmescPortHIntervalEntry 3 }

        mcmescPortHIntervalPort OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The CPE port within the shelf the card is in.  Valid
                         values are: 1 to 12.  The system automatically
                         determines the right value for this entry based
                         on the known (available) mcmesc cards."
                ::= { mcmescPortHIntervalEntry 4 }

        mcmescPortHIntervalNumber OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The interval number.  Valid values are: 1 to 96, where 1 
                         indicates the most recently completed interval."
                ::= { mcmescPortHIntervalEntry 5 }

        mcmescPortHIntervalDuration OBJECT-TYPE
                SYNTAX  DisplayString 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMESC CPE port's duration, in seconds, for specific interval.
                         The * indicates an incomplete interval resulted from interval setting 
                         change."
                ::= { mcmescPortHIntervalEntry 6 }

        mcmescPortHIntervalEns OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMESC CPE port's enabled seconds for specific interval."
                ::= { mcmescPortHIntervalEntry 7 }

        mcmescPortHIntervalLoss OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMESC CPE port's loss of signal seconds for specific interval." 
                ::= { mcmescPortHIntervalEntry 8 }

        mcmescPortHIntervalCrcErr OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMESC CPE port's CRC errs counter for specific interval."
                ::= { mcmescPortHIntervalEntry 9 }

        mcmescPortHIntervalOobErr OBJECT-TYPE
                SYNTAX  DisplayString 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMESC CPE port's Out-of_band error counter for specific 
                         interval."
                ::= { mcmescPortHIntervalEntry 10 }

        mcmescPortHIntervalRdpErr OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMESC CPE port's Running Disparity error counter for 
                         specific interval."
                ::= { mcmescPortHIntervalEntry 11 }

        --     Link port 96 interval entries

        mcmescLinkHIntervalTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF McmescLinkHIntervalEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entry for the mcmesc port counters."
                ::= { mcmescHist 4 }

        mcmescLinkHIntervalEntry OBJECT-TYPE
                SYNTAX  McmescLinkHIntervalEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { mcmescLinkHIntervalLocation, mcmescLinkHIntervalShelf,
                          mcmescLinkHIntervalSlot, mcmescLinkHIntervalNumber }
                ::= { mcmescLinkHIntervalTable 1 }

        McmescLinkHIntervalEntry ::=
                SEQUENCE
                {
                        mcmescLinkHIntervalLocation CardLocation,
                        mcmescLinkHIntervalShelf    CardShelf,
                        mcmescLinkHIntervalSlot     INTEGER,
                        mcmescLinkHIntervalNumber   INTEGER,
                        mcmescLinkHIntervalDuration DisplayString,
                        mcmescLinkHIntervalTsos     DisplayString,
                        mcmescLinkHIntervalLoss     DisplayString,
                        mcmescLinkHIntervalCrcErr   DisplayString,
                        mcmescLinkHIntervalOobErr   DisplayString,
                        mcmescLinkHIntervalRdpErr   DisplayString
                }


        mcmescLinkHIntervalLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the mcmesc card.  The values are: Local
                         or Remote.  The system automatically determines the
                         right value for this entry based on the known
                         mcmesc cards."
                ::= { mcmescLinkHIntervalEntry 1 }

        mcmescLinkHIntervalShelf OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 2.
                         The system automatically determines the right value
                         for this entry based on the known (available) mcmesc
                         cards."
                ::= { mcmescLinkHIntervalEntry 2 }

        mcmescLinkHIntervalSlot OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  The
                         system automatically determines the right value
                         for this entry based on the known (available)
                         mcmesc cards."
                ::= { mcmescLinkHIntervalEntry 3 }

        mcmescLinkHIntervalNumber OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The interval number.  Valid values are: 1 to 96, where 
                         1 indicates the most recently completed interval."
                ::= { mcmescLinkHIntervalEntry 4 }

        mcmescLinkHIntervalDuration OBJECT-TYPE
                SYNTAX  DisplayString 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMESC link port's duration, in seconds, for specific interval.
                         The * indicates an incomplete interval resulted from interval setting 
                         change."
                ::= { mcmescLinkHIntervalEntry 5 }

        mcmescLinkHIntervalTsos OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMESC link port's test-sequence on seconds for specific interval."
                ::= { mcmescLinkHIntervalEntry 6 }

        mcmescLinkHIntervalLoss OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMESC link port's loss of signal seconds for specific interval." 
                ::= { mcmescLinkHIntervalEntry 7 }

        mcmescLinkHIntervalCrcErr OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMESC link port's CRC errs counter for specific interval."
                ::= { mcmescLinkHIntervalEntry 8 }

        mcmescLinkHIntervalOobErr OBJECT-TYPE
                SYNTAX  DisplayString 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMESC link port's Out-of_band error counter for specific 
                         interval."
                ::= { mcmescLinkHIntervalEntry 9 }

        mcmescLinkHIntervalRdpErr OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMESC link port's Running Disparity error counter for 
                         specific interval."
                ::= { mcmescLinkHIntervalEntry 10 }

        -- CPE port's total perf counter of up to 96 intervals

        mcmescPortHTotalTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF McmescPortHTotalEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         mcmesc cpe port's total counters of up to 96 intervals."
                ::= { mcmescHist 5 }

        mcmescPortHTotalEntry OBJECT-TYPE
                SYNTAX  McmescPortHTotalEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { mcmescPortHTotalCardLocation, mcmescPortHTotalCardShelf,
                          mcmescPortHTotalCardSlot,  mcmescPortHTotalPort }
                ::= { mcmescPortHTotalTable 1 }

        McmescPortHTotalEntry ::=
                SEQUENCE
                {
                        mcmescPortHTotalCardLocation    CardLocation,
                        mcmescPortHTotalCardShelf       CardShelf,
                        mcmescPortHTotalCardSlot        INTEGER,
                        mcmescPortHTotalPort            INTEGER,
                        mcmescPortHTotalDuration        Counter,
                        mcmescPortHTotalEns             Counter,
                        mcmescPortHTotalLoss            Counter,
                        mcmescPortHTotalCrcErr          DisplayString,
                        mcmescPortHTotalOobErr          DisplayString,
                        mcmescPortHTotalRdpErr          DisplayString
                }

        mcmescPortHTotalCardLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Location of the MCMESC CPE port.  Valid values are: Local in
                         the same chassis, or remote to this chassis"
                ::= { mcmescPortHTotalEntry 1 }

        mcmescPortHTotalCardShelf OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1..2."
                ::= { mcmescPortHTotalEntry 2 }

        mcmescPortHTotalCardSlot OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the Module is in."
                ::= { mcmescPortHTotalEntry 3 }

        mcmescPortHTotalPort OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "CPE port's index."
                ::= { mcmescPortHTotalEntry 4 }

        mcmescPortHTotalDuration OBJECT-TYPE
                SYNTAX  Counter 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMESC CPE port's total duration of up to 96 intervals."
                ::= { mcmescPortHTotalEntry 5 }

       mcmescPortHTotalEns OBJECT-TYPE
               SYNTAX  Counter
               ACCESS  read-only
               STATUS  mandatory
               DESCRIPTION
                       "MCMESC CPE port's total enabled seconds during up to 96 
                        intervals."
              ::= { mcmescPortHTotalEntry 6 }

        mcmescPortHTotalLoss OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMESC CPE port's total loss of signal seconds during 
                         up to 96 intervals." 
                ::= { mcmescPortHTotalEntry 7 }

        mcmescPortHTotalCrcErr OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMESC CPE port's total CRC error counter during up to  
                         96 intervals."
                ::= { mcmescPortHTotalEntry 8 }

        mcmescPortHTotalOobErr OBJECT-TYPE
                SYNTAX  DisplayString 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMESC CPE port's total Out-Of_Band error counter during
                         up to 96 intervals." 
                ::= { mcmescPortHTotalEntry 9 }

        mcmescPortHTotalRdpErr OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMESC CPE port's total Running Disparity error counter 
                         during up to 96 intervals."
                ::= { mcmescPortHTotalEntry 10 }

        -- Link port's total perf counter of up to 96 intervals

        mcmescLinkHTotalTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF McmescLinkHTotalEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         mcmesc cpe port's total counters of up to 96 intervals."
                ::= { mcmescHist 6 }

        mcmescLinkHTotalEntry OBJECT-TYPE
                SYNTAX  McmescLinkHTotalEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { mcmescLinkHTotalCardLocation, mcmescLinkHTotalCardShelf,
                          mcmescLinkHTotalCardSlot }
                ::= { mcmescLinkHTotalTable 1 }

        McmescLinkHTotalEntry ::=
                SEQUENCE
                {
                        mcmescLinkHTotalCardLocation    CardLocation,
                        mcmescLinkHTotalCardShelf       CardShelf,
                        mcmescLinkHTotalCardSlot        INTEGER,
                        mcmescLinkHTotalDuration        Counter,
                        mcmescLinkHTotalTsos            Counter,
                        mcmescLinkHTotalLoss            Counter,
                        mcmescLinkHTotalCrcErr          DisplayString,
                        mcmescLinkHTotalOobErr          DisplayString,
                        mcmescLinkHTotalRdpErr          DisplayString,
                        mcmescLinkHTotalBer             DisplayString  
                }

        mcmescLinkHTotalCardLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Location of the MCMESC link port.  Valid values are: Local in
                         the same chassis, or remote to this chassis"
                ::= { mcmescLinkHTotalEntry 1 }

        mcmescLinkHTotalCardShelf OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1..2."
                ::= { mcmescLinkHTotalEntry 2 }

        mcmescLinkHTotalCardSlot OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the Module is in."
                ::= { mcmescLinkHTotalEntry 3 }

        mcmescLinkHTotalDuration OBJECT-TYPE
                SYNTAX  Counter 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMESC link port's total duration of up to 96 intervals."
                ::= { mcmescLinkHTotalEntry 4 }

       mcmescLinkHTotalTsos OBJECT-TYPE
               SYNTAX  Counter
               ACCESS  read-only
               STATUS  mandatory
               DESCRIPTION
                       "MCMESC link port's total test-sequence on seconds during up to 96 
                        intervals."
              ::= { mcmescLinkHTotalEntry 5 }

        mcmescLinkHTotalLoss OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMESC link port's total loss of signal seconds during 
                         up to 96 intervals." 
                ::= { mcmescLinkHTotalEntry 6 }

        mcmescLinkHTotalCrcErr OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMESC link port's total CRC error counter during up to  
                         96 intervals."
                ::= { mcmescLinkHTotalEntry 7 }

        mcmescLinkHTotalOobErr OBJECT-TYPE
                SYNTAX  DisplayString 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMESC link port's total Out-Of_Band error counter during
                         up to 96 intervals." 
                ::= { mcmescLinkHTotalEntry 8 }

        mcmescLinkHTotalRdpErr OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "MCMESC link port's total Running Disparity error counter 
                         during up to 96 intervals."
                ::= { mcmescLinkHTotalEntry 9 }

        -- The elements in the systemCond subgroup of the specialConditions

        sysCStatus      OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The global status of the system as computed based on
                         the traps (events) that are generated.  Choices are:
                         Critical, Major, Minor or Normal."
                ::= { systemCond 1 }

        sysCSetMode     OBJECT-TYPE
                SYNTAX  FlagType
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "If on, the special conditions counters will be
                         activated.  These counters continue counting until
                         the mode is off.  On startup, this flag is off."
                ::= { systemCond 2 }

        sysCAvailTime   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds since this mode is started
                         that the system has been up and running. The Criteria
                         for the system available time is having at least one CP
                         running with atmost non-service affecting minor
                         alarm system status"
                ::= { systemCond 3 }

        sysCErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds since this mode is started
                         that the device has not experienced any alarms.  This
                         counter is across all cards in the chassis.  The
                         system must be in Normal status for this counter to
                         be incremented."
                ::= { systemCond 4 }


        -- The elements in the downloadCond subgroup of the specialConditions

        dlCStatus       OBJECT-TYPE
                SYNTAX  DownloadStatus
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The global status of the download task.  The download task 
                (download to the device) is either ftp-inprogress, module 
                update inprogress or currently idle.  Since only one download 
                at the time is handled by the system, this flag is set to 
                inprogress as soon as any download starts.  
                It is reset back to idle when the download is completed.  
                This flag is set to idle on system startup.  This flag 
                can be remotely set to idle if a previous FTP download 
                was interrupted."
                ::= { downloadCond 1 }

        dlCOkDownloads  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of successful downloads in this time
                         interval (15 minutes)."
                ::= { downloadCond 2 }

        dlCBadDownloads OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of failed downloads in this time
                         interval (15 minutes)."
                ::= { downloadCond 3 }

        dlCLongestTime  OBJECT-TYPE
                SYNTAX  Gauge
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Longest time for any download, in seconds, in this
                         time interval (15 minutes)."
                ::= { downloadCond 4 }

        dlCLongestSize  OBJECT-TYPE
                SYNTAX  Gauge
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Longest download size for any download, in bytes, in
                         this time interval (15 minutes)."
                ::= { downloadCond 5 }

        dlCCounterFlag  OBJECT-TYPE
                SYNTAX  FlagType
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Turns software counters On or Off."
                ::= { downloadCond 6 }

        -- The elements in the cpCond subgroup of the specialConditions

        cpCNumEvents    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total number of events received by the active CP
                         since this mode was activated."
                ::= { cpCond 1 }

        cpCTrapsSent    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total number of traps sent by the active CP since
                         this mode was activated."
                ::= { cpCond 2 }

        cpCSNMPCmdsRcvd OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total number of SNMP commands received by the active
                         CP since this mode was activated."
                ::= { cpCond 3 }

        cpCCounterFlag  OBJECT-TYPE
                SYNTAX  FlagType
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Turns software counters On or Off."
                ::= { cpCond 4 }

        cpCCntrTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF CpCCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entry for the software counters.  It is only
             applicable to the active MPM card."
                ::= { cpCond 5 }

        cpCCntrEntry    OBJECT-TYPE
                SYNTAX  CpCCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { cpCCntrShelf, cpCCntrSlot, cpCCntrType }
                ::= { cpCCntrTable 1 }

        CpCCntrEntry    ::=
                SEQUENCE
                {
                        cpCCntrShelf    CardShelf,
                        cpCCntrSlot     INTEGER,
                        cpCCntrType     INTEGER,
                        cpCTotPktSent   Counter,
                        cpCTotPktRcvd   Counter,
                        cpCBadPktRcvd   Counter,
                        cpCTotBadTrans  Counter,
                        cpCBytesSent    Counter,
                        cpCBytesRcvd    Counter,
                        cpCMsgsDlvrd    Counter,
                        cpCBufAllocFail Counter,
                        cpCEcbAllocFail Counter
                }

        cpCCntrShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 10.
                         The system automatically determines the right value
                         for this entry based on the value of the current
                         active CP card."
                ::= { cpCCntrEntry 1 }

        cpCCntrSlot     OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  The
                         system automatically determines the right value
                         for this entry based on the value of the current
                         active CP card."
                ::= { cpCCntrEntry 2 }

        cpCCntrType     OBJECT-TYPE
                SYNTAX  INTEGER { spi(1) }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The type of the software counter data in this row.
                         The data is collected for the SPI data channels."
                ::= { cpCCntrEntry 3 }

        cpCTotPktSent   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets sent over the given data
                         channel."
                ::= { cpCCntrEntry 4 }

        cpCTotPktRcvd   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets received over the given
                         data channel."
                ::= { cpCCntrEntry 5 }

        cpCBadPktRcvd   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data packets received over the given
                         data channel."
                ::= { cpCCntrEntry 6 }

        cpCTotBadTrans  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data transmissions over the given
                         data channel."
                ::= { cpCCntrEntry 7 }

        cpCBytesSent    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total number of bytes sent over the given
                         data channel."
                ::= { cpCCntrEntry 8 }

        cpCBytesRcvd    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total number of data bytes received over the given
                         data channel."
                ::= { cpCCntrEntry 9 }

        cpCMsgsDlvrd    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of complete messages delivered over the
                         given data channel."
                ::= { cpCCntrEntry 10 }

        cpCBufAllocFail OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Number of buffer allocation failures for the given
                         data channel."
                ::= { cpCCntrEntry 11 }

        cpCEcbAllocFail OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Number of Event Control Block allocation failures
                         for the given data channel."
                ::= { cpCCntrEntry 12 }

        cpCPerfTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF CpCPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each communication processor"
                ::= { cpCond 6 }

        cpCPerfEntry    OBJECT-TYPE
                SYNTAX  CpCPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { cpCPerfShelf, cpCPerfSlot }
                ::= { cpCPerfTable 1 }

        CpCPerfEntry    ::=
                SEQUENCE
                {
                        cpCPerfShelf    CardShelf,
                        cpCPerfSlot     INTEGER,
                        cpCPerfMode     RedundancyMode,
                        cpCPerfState    CardState,
                        cpCPerfStatus   CardStatus,
                        cpCAvailTime    Counter,
                        cpCErrFreeSecs  Counter
                }

        cpCPerfShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 10"
                ::= { cpCPerfEntry 1 }

        cpCPerfSlot     OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { cpCPerfEntry 2 }

        cpCPerfMode     OBJECT-TYPE
                SYNTAX  RedundancyMode
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The valid types are: active CP or standby CP"
                ::= { cpCPerfEntry 3 }

        cpCPerfState    OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The state of the communication card.  The states
                         are: online, offline, empty, loopback or diagnostics."
                ::= { cpCPerfEntry 4 }

        cpCPerfStatus   OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The status of the communication processor.  This
                         status represents the state of the communication
                         processor and in general is different from the
                         status of the system."
                ::= { cpCPerfEntry 5 }

        cpCAvailTime    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds since this mode is started
                         that this CP has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { cpCPerfEntry 7 }

        cpCErrFreeSecs  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds since this mode is started
                         that this CP has not experienced any alarms."
                ::= { cpCPerfEntry 8 }


        -- The elements in the ccCond subgroup of the specialConditions

        ccCNumEvents    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total number of events received for all CC's since
                         this mode was started."
                ::= { ccCond 1 }

        ccCCntrTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF CcCCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entry for the software counters."
                ::= { ccCond 2 }

        ccCCntrEntry    OBJECT-TYPE
                SYNTAX  CcCCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { ccCCntrLocation, ccCCntrShelf, ccCCntrSlot,
                        ccCCntrType }
                ::= { ccCCntrTable 1 }

        CcCCntrEntry    ::=
                SEQUENCE
                {
                        ccCCntrLocation CardLocation,
                        ccCCntrShelf    CardShelf,
                        ccCCntrSlot     INTEGER,
                        ccCCntrType     INTEGER,
                        ccCCounterFlag  FlagType,
                        ccCTotPktSent   Counter,
                        ccCTotPktRcvd   Counter,
                        ccCBadPktRcvd   Counter,
                        ccCTotBadTrans  Counter,
                        ccCBytesSent    Counter,
                        ccCBytesRcvd    Counter,
                        ccCMsgsDlvrd    Counter,
                        ccCBufAllocFail Counter,
                        ccCEcbAllocFail Counter,
                        ccCClearCntrs   ResetType 
                }

        ccCCntrLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  not-accessible 
                STATUS  mandatory
                DESCRIPTION
                        "The location of the CC card.  The values are: Local
                         or Remote.  The system automatically determines the
                         right value for this entry based on the known
                         CC cards."
                ::= { ccCCntrEntry 1 }

        ccCCntrShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 10.
                         The system automatically determines the right value
                         for this entry based on the known (available) CC
                         cards."
                ::= { ccCCntrEntry 2 }

        ccCCntrSlot     OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  The
                         system automatically determines the right value
                         for this entry based on the known (available)
                         CC cards."
                ::= { ccCCntrEntry 3 }

        ccCCntrType     OBJECT-TYPE
                SYNTAX  INTEGER { spi(1), iwm(2) }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The type of the software counter data in this row.
                         The data is collected for the SPI data channels."
                ::= { ccCCntrEntry 4 }

        ccCCounterFlag  OBJECT-TYPE
                SYNTAX  FlagType
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Turns software counters, both On or both Off for this CC. When Off Clears both counters Statistic information "
                ::= { ccCCntrEntry 5 }

        ccCTotPktSent   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets sent over the given data
                         channel."
                ::= { ccCCntrEntry 6 }

        ccCTotPktRcvd   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets received over the given
                         data channel."
                ::= { ccCCntrEntry 7 }

        ccCBadPktRcvd   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data packets received over the given
                         data channel."
                ::= { ccCCntrEntry 8 }

        ccCTotBadTrans  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data transmissions over the given
                         data channel."
                ::= { ccCCntrEntry 9 }

        ccCBytesSent    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total number of bytes sent over the given
                         data channel."
                ::= { ccCCntrEntry 10 }

        ccCBytesRcvd    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total number of data bytes received over the given
                         data channel."
                ::= { ccCCntrEntry 11 }

        ccCMsgsDlvrd    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of complete messages delivered over the
                         given data channel."
                ::= { ccCCntrEntry 12 }

        ccCBufAllocFail OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Number of buffer allocation failures for the given
                         data channel."
                ::= { ccCCntrEntry 13 }

        ccCEcbAllocFail OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Number of Event Control Block allocation failures
                         for the given data channel."
                ::= { ccCCntrEntry 14 }
    ccCClearCntrs    OBJECT-TYPE
        SYNTAX  ResetType
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
            "If the value is reset, all software counters for this
             15 minute interval are reset to zero.  A get on this
             will always return other."
        ::= { ccCCntrEntry 15 }

        ccCPerfTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF CcCPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each channel card."
                ::= { ccCond 3 }

        ccCPerfEntry    OBJECT-TYPE
                SYNTAX  CcCPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { ccCPerfLocation, ccCPerfShelf, ccCPerfSlot }
                ::= { ccCPerfTable 1 }

        CcCPerfEntry    ::=
                SEQUENCE
                {
                        ccCPerfLocation     CardLocation,
                        ccCPerfShelf        CardShelf,
                        ccCPerfSlot         INTEGER,
                        ccCPerfState        CardState,
                        ccCPerfStatus       CardStatus,
                        ccCAvailTime        Counter,
                        ccCErrFreeSecs      Counter,
                        ccCBiasCurrent      INTEGER,
                        ccCModulation       INTEGER,
                        ccCApc              INTEGER,
                        ccCIwmModulation    INTEGER,
                        ccCLaserOnOff       FlagType,
                        ccCTemperature      Gauge,
                        ccCIntensity        Gauge,
                        ccCSignalStrength   Gauge,
                        ccCLossOfLight      Boolean,
                        ccCSignalDetect     Boolean,
                        ccCRefClock         INTEGER,
                        ccCClockDiv         INTEGER,
                        ccCProtectionMode   INTEGER
                }

        ccCPerfLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card.  Valid choices are Local
                         or Remote.  The system automatically selects this
                         value based on the known (available) CC cards."
                ::= { ccCPerfEntry 1 }

        ccCPerfShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 10"
                ::= { ccCPerfEntry 2 }

        ccCPerfSlot     OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { ccCPerfEntry 3 }

        ccCPerfState    OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The state of the channel card.  The states'
                         are: online, offline, empty, loopback or diagnostics."
                ::= { ccCPerfEntry 4 }

        ccCPerfStatus   OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The status of the channel card.  This
                         status represents the status of the communication
                         processor and in general is different from the
                         status of the system."
                ::= { ccCPerfEntry 5 }

        ccCAvailTime    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this CC has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { ccCPerfEntry 6 }

        ccCErrFreeSecs  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this CC has not experienced any alarms."
                ::= { ccCPerfEntry 7 }

        ccCBiasCurrent  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Bias current for the optical laser."
                ::= { ccCPerfEntry 8 }

        ccCModulation   OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The frequency modulation for the optical laser."
                ::= { ccCPerfEntry 9 }

        ccCApc          OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The APC value."
                ::= { ccCPerfEntry 10 }

        ccCIwmModulation  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The frequency modulation for the IWM channel."
                ::= { ccCPerfEntry 11 }

        ccCLaserOnOff   OBJECT-TYPE
                SYNTAX  FlagType
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The laser On/Off flag."
                ::= { ccCPerfEntry 12 }

        ccCTemperature  OBJECT-TYPE
                SYNTAX  Gauge
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The current temperature, or the operating temperature
                         of the optical device."
                ::= { ccCPerfEntry 13 }

        ccCIntensity    OBJECT-TYPE
                SYNTAX  Gauge
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The intensity of the optical light."
                ::= { ccCPerfEntry 14 }

        ccCSignalStrength OBJECT-TYPE
                SYNTAX  Gauge
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The current signal strength for the optical path."
                ::= { ccCPerfEntry 15 }

        ccCLossOfLight  OBJECT-TYPE
                SYNTAX  Boolean
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "If set to true, no laser light is present.  If set to
                         false, no loss of light has occurred."
                ::= { ccCPerfEntry 16 }

        ccCSignalDetect OBJECT-TYPE
                SYNTAX  Boolean
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "If set to true, signal is detected.  If set to false,
                         no signal is present."
                ::= { ccCPerfEntry 17 }

        ccCRefClock     OBJECT-TYPE
                SYNTAX  INTEGER {   en1660 (1),
                            en1944(2),
                            en1953(3)
                } 
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The value of the reference clock in decimal notation.
                         For a given value, like 1660, the actual value is
                         16.60-EN.  In otherwords, assume a two digit decimal
                         point, plus any appropriate scaling factor."
                ::= { ccCPerfEntry 18 }

        ccCClockDiv     OBJECT-TYPE
                SYNTAX  INTEGER { dout-1250(1), dout-622(2), dout-155(3) }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The clock divisor.  Values are 1250, 622 or 155 in the
                         appropriate clock frequency scale."
                ::= { ccCPerfEntry 19 }

        ccCProtectionMode     OBJECT-TYPE
                SYNTAX  INTEGER 
                        { 
                            active(1), 
                            standby(2), 
                            na(3) 
                        }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "UPSR Protection Mode:  active, standby and na."
                ::= { ccCPerfEntry 20 }


        -- The elements in the muxCond subgroup of the specialConditions

        muxCNumEvents   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         MUX's since this mode is started."
                ::= { muxCond 1 }

        muxCPerfTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF MuxCPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each mux/demux card"
                ::= { muxCond 2 }

        muxCPerfEntry   OBJECT-TYPE
                SYNTAX  MuxCPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { muxCPerfLocation, muxCPerfShelf, muxCPerfSlot }
                ::= { muxCPerfTable 1 }

        MuxCPerfEntry   ::=
                SEQUENCE
                {
                        muxCPerfLocation  CardLocation,
                        muxCPerfShelf     CardShelf,
                        muxCPerfSlot      INTEGER,
                        muxCType          INTEGER,
                        muxCPerfState     CardState,
                        muxCPerfStatus    CardStatus,
                        muxCAvailTime     Counter,
                        muxCErrFreeSecs   Counter
                }

        muxCPerfLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card.  Choices are local or
                         remote."
                ::= { muxCPerfEntry 1 }

        muxCPerfShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 10"
                ::= { muxCPerfEntry 2 }

        muxCPerfSlot    OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { muxCPerfEntry 3 }

        muxCType        OBJECT-TYPE
                SYNTAX  INTEGER { mux(4), demux(5), w4cd(10), w2cmd(13), w4cm(21)}
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The type of the mux.  The choices are: mux or demux."
                ::= { muxCPerfEntry 4 }

        muxCPerfState   OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The status of the mux card.  The states are:
                         online, offline, empty, loopback or diag."
                ::= { muxCPerfEntry 5 }

        muxCPerfStatus  OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The status of the mux card.  This status represents
                         the status of the mux card and in general is
                         different from the status of the system."
                ::= { muxCPerfEntry 6 }

        muxCAvailTime   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this Mux has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { muxCPerfEntry 7 }

        muxCErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this mux has not experienced any alarms."
                ::= { muxCPerfEntry 8 }

        muxCCounterFlag   OBJECT-TYPE
                SYNTAX  FlagType
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Turns special condition software counters On or Off
             for this card. Default is off."
                ::= { muxCond 3}


        -- The elements in the psCond subgroup of the specialConditions

        psCNumEvents    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         Power Supplies since this mode is started."
                ::= { psCond 1 }

        psCVoltageLevel3pt3Volt     OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Voltage Level of the 3.3 V power supply.  Need to divide 
                         this value by ten to get the actual voltage level."  
                ::= { psCond 2 }

        psCVoltageLevel5Volt      OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Voltage Level of the 5 V power supply.  Need to divide 
                         this value by ten to get the actual voltage level."  
                ::= { psCond 3 }

        psCVoltageLevel12Volt     OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Voltage Level of the 12 V power supply.  Need to divide 
                         this value by ten to get the actual voltage level."  
                ::= { psCond 4 }


        psCPerfTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF PsCPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each power supply card"
                ::= { psCond 5 }

        psCPerfEntry    OBJECT-TYPE
                SYNTAX  PsCPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { psCPerfID }
                ::= { psCPerfTable 1 }

        PsCPerfEntry    ::=
                SEQUENCE
                {
                        psCPerfID       INTEGER,
                        psCPerfType     RedundancyMode,
                        psCPerfState    CardState,
                        psCPerfStatus   CardStatus
                }

        psCPerfID    OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The module id where ps is in.  Valid values are: 1 to 4"
                ::= { psCPerfEntry 1 }

        psCPerfType     OBJECT-TYPE
                SYNTAX  RedundancyMode
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The type of the power supply card.  The choices are:
                         active (primary PS) or standby."
                ::= { psCPerfEntry 2 }

        psCPerfState    OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The state of the power supply card.  The states are:
                         online, offline, empty, loopback or diagnostics."
                ::= { psCPerfEntry 3 }

        psCPerfStatus   OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The status of the power supply card.  This status
                         represents the status of the ps card and in general is
                         different from the status of the system."
                ::= { psCPerfEntry 4 }


        -- The elements in the fadmCond subgroup of the specialConditions

        fadmCNumEvents  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         FADM's since this mode is started."
                ::= { fadmCond 1 }

        fadmCCounterFlag  OBJECT-TYPE
                SYNTAX  FlagType
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Turns software counters On or Off for this FADM."
                ::= { fadmCond 2 }

        fadmCPerfTable  OBJECT-TYPE
                SYNTAX  SEQUENCE OF FadmCPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each fadm card"
                ::= { fadmCond 3 }

        fadmCPerfEntry  OBJECT-TYPE
                SYNTAX  FadmCPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { fadmCPerfLocation, fadmCPerfShelf, fadmCPerfSlot }
                ::= { fadmCPerfTable 1 }

        FadmCPerfEntry   ::=
                SEQUENCE
                {
                        fadmCPerfLocation  CardLocation,
                        fadmCPerfShelf     CardShelf,
                        fadmCPerfSlot      INTEGER,
                        fadmCPerfState     CardState,
                        fadmCPerfStatus    CardStatus,
                        fadmCAvailTime     Counter,
                        fadmCErrFreeSecs   Counter
                }

        fadmCPerfLocation  OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card.  Choices are local or
                         remote."
                ::= { fadmCPerfEntry 1 }

        fadmCPerfShelf  OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 10"
                ::= { fadmCPerfEntry 2 }

        fadmCPerfSlot   OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { fadmCPerfEntry 3 }

        fadmCPerfState  OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The status of the mux card.  The states are:
                         online, offline, empty, loopback or diag."
                ::= { fadmCPerfEntry 5 }

        fadmCPerfStatus OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The status of the mux card.  This status represents
                         the status of the mux card and in general is
                         different from the status of the system."
                ::= { fadmCPerfEntry 6 }

        fadmCAvailTime  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this Mux has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { fadmCPerfEntry 7 }

        fadmCErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this mux has not experienced any alarms."
                ::= { fadmCPerfEntry 8 }

        -- The elements in the oppmCond subgroup of the specialConditions


        oppmCNumEvents  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         OPPMs' since this mode is started."
                ::= { oppmCond 1 }


        oppmCPerfTable  OBJECT-TYPE
                SYNTAX  SEQUENCE OF OppmCPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each oppm card"
                ::= { oppmCond 2 }

        oppmCPerfEntry  OBJECT-TYPE
                SYNTAX  OppmCPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { oppmCPerfLocation, oppmCPerfShelf, oppmCPerfSlot }
                ::= { oppmCPerfTable 1 }

        OppmCPerfEntry   ::=
                SEQUENCE
                {
                        oppmCPerfLocation  CardLocation,
                        oppmCPerfShelf     CardShelf,
                        oppmCPerfSlot      INTEGER,
                        oppmCPerfState     CardState,
                        oppmCPerfStatus    CardStatus,
                        oppmCAvailTime     Counter,
                        oppmCErrFreeSecs   Counter
                }

        oppmCPerfLocation  OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card.  Choices are local or
                         remote."
                ::= { oppmCPerfEntry 1 }

        oppmCPerfShelf  OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 10"
                ::= { oppmCPerfEntry 2 }

        oppmCPerfSlot   OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { oppmCPerfEntry 3 }

        oppmCPerfState  OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The status of the oppm card.  The states are:
                         online, offline, empty, loopback or diag."
                ::= { oppmCPerfEntry 4 }

        oppmCPerfStatus OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The status of the oppm card.  This status represents
                         the status of the oppm card and in general is
                         different from the status of the system."
                ::= { oppmCPerfEntry 5 }

        oppmCAvailTime  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this oppm has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { oppmCPerfEntry 6 }

        oppmCErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this oppm has not experienced any alarms."
                ::= { oppmCPerfEntry 7 }

        oppmCCounterFlag OBJECT-TYPE
                SYNTAX  FlagType
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Turns special condition software counters On or Off for
                         this card. Default is off."
                ::= { oppmCond 3}


        -- The elements in the mcmCond subgroup of the specialConditions

        mcmCNumEvents   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total number of events received for all MCM's since
                         this mode was started."
                ::= { mcmCond 1 }

        mcmCCntrTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF McmCCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entry for the software counters."
                ::= { mcmCond 2 }

        mcmCCntrEntry   OBJECT-TYPE
                SYNTAX  McmCCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { mcmCCntrLocation, mcmCCntrShelf, mcmCCntrSlot,
                        mcmCCntrType }
                ::= { mcmCCntrTable 1 }

        McmCCntrEntry    ::=
                SEQUENCE
                {
                        mcmCCntrLocation CardLocation,
                        mcmCCntrShelf    CardShelf,
                        mcmCCntrSlot     INTEGER,
                        mcmCCntrType     INTEGER,
                        mcmCCounterFlag  FlagType,
                        mcmCTotPktSent   Counter,
                        mcmCTotPktRcvd   Counter,
                        mcmCBadPktRcvd   Counter,
                        mcmCTotBadTrans  Counter,
                        mcmCBytesSent    Counter,
                        mcmCBytesRcvd    Counter,
                        mcmCMsgsDlvrd    Counter,
                        mcmCBufAllocFail Counter,
                        mcmCEcbAllocFail Counter,
                        mcmCClearCntrs   ResetType 
                }

        mcmCCntrLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The location of the MCM card.  The values are: Local
                         or Remote.  The system automatically determines the
                         right value for this entry based on the known
                         MCM cards."
                ::= { mcmCCntrEntry 1 }

        mcmCCntrShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 10.
                         The system automatically determines the right value
                         for this entry based on the known (available) MCM
                         cards."
                ::= { mcmCCntrEntry 2 }

        mcmCCntrSlot    OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in.  The
                         system automatically determines the right value
                         for this entry based on the known (available)
                         MCM cards."
                ::= { mcmCCntrEntry 3 }

        mcmCCntrType    OBJECT-TYPE
                SYNTAX  INTEGER { spi(1), iwm(2) }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The type of the software counter data in this row.
                         The data is collected for the SPI data channels."
                ::= { mcmCCntrEntry 4 }

        mcmCCounterFlag OBJECT-TYPE
                SYNTAX  FlagType
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Turns software counters On or Off for this MCM."
                ::= { mcmCCntrEntry 5 }

        mcmCTotPktSent  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets sent over the given data
                         channel."
                ::= { mcmCCntrEntry 6 }

        mcmCTotPktRcvd  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of data packets received over the given
                         data channel."
                ::= { mcmCCntrEntry 7 }

        mcmCBadPktRcvd  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data packets received over the given
                         data channel."
                ::= { mcmCCntrEntry 8 }

        mcmCTotBadTrans OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of bad data transmissions over the given
                         data channel."
                ::= { mcmCCntrEntry 9 }

        mcmCBytesSent   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total number of bytes sent over the given
                         data channel."
                ::= { mcmCCntrEntry 10 }

        mcmCBytesRcvd   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total number of data bytes received over the given
                         data channel."
                ::= { mcmCCntrEntry 11 }

        mcmCMsgsDlvrd   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of complete messages delivered over the
                         given data channel."
                ::= { mcmCCntrEntry 12 }

        mcmCBufAllocFail OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Number of buffer allocation failures for the given
                         data channel."
                ::= { mcmCCntrEntry 13 }

        mcmCEcbAllocFail OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Number of Event Control Block allocation failures
                         for the given data channel."
                ::= { mcmCCntrEntry 14 }

        mcmCClearCntrs  OBJECT-TYPE
                SYNTAX  ResetType
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "If the value is reset, all software counters for this
                         15 minute interval are reset to zero.  A get on this
                         will always return other."
                ::= { mcmCCntrEntry 15 }

        mcmCPerfTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF McmCPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each channel card"
                ::= { mcmCond 3 }

        mcmCPerfEntry   OBJECT-TYPE
                SYNTAX  McmCPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { mcmCPerfLocation, mcmCPerfShelf, mcmCPerfSlot }
                ::= { mcmCPerfTable 1 }

        McmCPerfEntry    ::=
                SEQUENCE
                {
                        mcmCPerfLocation   CardLocation,
                        mcmCPerfShelf      CardShelf,
                        mcmCPerfSlot       INTEGER,
                        mcmCPerfState      CardState,
                        mcmCPerfStatus     CardStatus,
                        mcmCAvailTime      Counter,
                        mcmCErrFreeSecs    Counter,
                        mcmCBiasCurrent    INTEGER,
                        mcmCModulation     INTEGER,
                        mcmCApc            INTEGER,
                        mcmCIwmModulation  INTEGER,
                        mcmCLaserOnOff     FlagType,
                        mcmCTemperature    Gauge,
                        mcmCIntensity      Gauge,
                        mcmCSignalStrength Gauge,
                        mcmCLossOfLight    Boolean,
                        mcmCSignalDetect   Boolean,
                        mcmCRefClock       INTEGER,
                        mcmCClockDiv       INTEGER
                }

        mcmCPerfLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card.  Valid choices are Local
                         or Remote.  The system automatically selects this
                         value based on the known (available) CC cards."
                ::= { mcmCPerfEntry 1 }

        mcmCPerfShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 10"
                ::= { mcmCPerfEntry 2 }

        mcmCPerfSlot    OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { mcmCPerfEntry 3 }

        mcmCPerfState   OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The state of the channel card.  The states'
                         are: online, offline, empty, loopback or diagnostics."
                ::= { mcmCPerfEntry 4 }

        mcmCPerfStatus  OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The status of the channel card.  This
                         status represents the status of the communication
                         processor and in general is different from the
                         status of the system."
                ::= { mcmCPerfEntry 5 }

        mcmCAvailTime   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this CC has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { mcmCPerfEntry 6 }

        mcmCErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this MCM has not experienced any alarms."
                ::= { mcmCPerfEntry 7 }

        mcmCBiasCurrent OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Bias current for the optical laser."
                ::= { mcmCPerfEntry 8 }

        mcmCModulation  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The frequency modulation for the optical laser."
                ::= { mcmCPerfEntry 9 }

        mcmCApc         OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The APC value."
                ::= { mcmCPerfEntry 10 }

        mcmCIwmModulation  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The frequency modulation for the IWM channel."
                ::= { mcmCPerfEntry 11 }

        mcmCLaserOnOff  OBJECT-TYPE
                SYNTAX  FlagType
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The laser On/Off flag."
                ::= { mcmCPerfEntry 12 }

        mcmCTemperature OBJECT-TYPE
                SYNTAX  Gauge
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The current temperature, or the operating temperature
                         of the optical device."
                ::= { mcmCPerfEntry 13 }

        mcmCIntensity   OBJECT-TYPE
                SYNTAX  Gauge
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The intensity of the optical light."
                ::= { mcmCPerfEntry 14 }

        mcmCSignalStrength OBJECT-TYPE
                SYNTAX  Gauge
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The current signal strength for the optical path."
                ::= { mcmCPerfEntry 15 }

        mcmCLossOfLight OBJECT-TYPE
                SYNTAX  Boolean
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "If set to true, no laser light is present.  If set to
                         false, no loss of light has occurred."
                ::= { mcmCPerfEntry 16 }

        mcmCSignalDetect OBJECT-TYPE
                SYNTAX  Boolean
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "If set to true, signal is detected.  If set to false,
                         no signal is present."
                ::= { mcmCPerfEntry 17 }

        mcmCRefClock    OBJECT-TYPE
                SYNTAX  INTEGER 
                        {
                            en1660 (1),
                            en1944(2),
                            en1953(3)
                        }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The value of the reference clock in decimal notation.
                         For a given value, like 1660, the actual value is
                         16.60-EN.  In otherwords, assume a two digit decimal
                         point, plus any appropriate scaling factor."
                ::= { mcmCPerfEntry 18 }

        mcmCClockDiv    OBJECT-TYPE
                SYNTAX  INTEGER { dout-1250(1), dout-622(2), dout-155(3) }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The clock divisor.  Values are 1250, 622 or 155 in the
                         appropriate clock frequency scale."
                ::= { mcmCPerfEntry 19 }

        mcmPortCCntrTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF McmPortCCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         MCM port's current counters."
                ::= { mcmCond 4 }

        mcmPortCCntrEntry OBJECT-TYPE
                SYNTAX  McmPortCCntrEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { mcmPortCCntrCardLocation, mcmPortCCntrCardShelf,
                        mcmPortCCntrCardSlot,  mcmPortCCntrIndex }
                ::= { mcmPortCCntrTable 1 }

        McmPortCCntrEntry        ::=
                SEQUENCE
                {
                        mcmPortCCntrCardLocation    CardLocation,
                        mcmPortCCntrCardShelf       CardShelf,
                        mcmPortCCntrCardSlot        INTEGER,
                        mcmPortCCntrIndex           INTEGER,
                        mcmPortCCntrASs             Counter,
                    --  mcmPortCCntrFrameASs        Counter,
                        mcmPortCCntrFEs             Counter,
                        mcmPortCCntrCRCErrs         Counter,
                        mcmPortCCntrSESs            Counter,
                        mcmPortCCntrSEFSs           Counter,
                        mcmPortCCntrUASs            Counter,
                        mcmPortCCntrLESs            Counter,
                        mcmPortCCntrBESs            Counter,
                        mcmPortCCntrDMs             Counter,
                        mcmPortCCntrLCVs            Counter
                }

        mcmPortCCntrCardLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Location of the MCM port.  Valid values are:
             Local in the same chassis, or remote to this
             chassis"
                ::= { mcmPortCCntrEntry 1 }

        mcmPortCCntrCardShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values
             are: 2..3."
                ::= { mcmPortCCntrEntry 2 }

        mcmPortCCntrCardSlot     OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the Module is in."
                ::= { mcmPortCCntrEntry 3 }

        mcmPortCCntrIndex      OBJECT-TYPE
                SYNTAX  INTEGER 
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Port's index."
                ::= { mcmPortCCntrEntry 4 }

        mcmPortCCntrASs OBJECT-TYPE
                SYNTAX  Counter 
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "mcm port's ASs counter less than 15 mins."
                ::= { mcmPortCCntrEntry 5 }

        --mcmPortCCntrFrameASs      OBJECT-TYPE
        --        SYNTAX  Counter
        --        ACCESS  not-accessible
        --        STATUS  mandatory
        --        DESCRIPTION
        --                "MCM port's FrameASs counter less than 15 mins."
        --        ::= { mcmPortCCntrEntry 6 }

        mcmPortCCntrFEs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "MCM port's FEs counter less than 15 mins." 
                ::= { mcmPortCCntrEntry 7 }

        mcmPortCCntrCRCErrs    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "MCM port's CRC errs counter less than 15 mins."
                ::= { mcmPortCCntrEntry 8 }

        mcmPortCCntrSESs OBJECT-TYPE
                SYNTAX  Counter 
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "mcm port's SESs counter less than 15 mins."
                ::= { mcmPortCCntrEntry 9 }

        mcmPortCCntrSEFSs      OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "MCM port's SEFSs counter less than 15 mins."
                ::= { mcmPortCCntrEntry 10 }

        mcmPortCCntrUASs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "MCM port's UASs counter less than 15 mins." 
                ::= { mcmPortCCntrEntry 11 }

        mcmPortCCntrLESs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "MCM port's LESs counter less than 15 mins."
                ::= { mcmPortCCntrEntry 12 }

        mcmPortCCntrBESs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "MCM port's BESs counter less than 15 mins."
                ::= { mcmPortCCntrEntry 13 }

        mcmPortCCntrDMs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "MCM port's DMSs counter less than 15 mins."
                ::= { mcmPortCCntrEntry 14 }

        mcmPortCCntrLCVs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "MCM port's LCVs counter less than 15 mins."
                ::= { mcmPortCCntrEntry 15 }

        -- The elements in the fnCond subgroup of the specialConditions subgroup

        fnCNumEvents    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible 
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         Fans since this mode is started."
                ::= { fnCond 1 }

        fnCPerfTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF FnCPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each fan module."
                ::= { fnCond 2 }

        fnCPerfEntry    OBJECT-TYPE
                SYNTAX  FnCPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { fnCPerfID }
                ::= { fnCPerfTable 1 }

        FnCPerfEntry     ::=
                SEQUENCE
                {
                        fnCPerfID       INTEGER,
                        fnCPerfState    INTEGER,
                        fnCPerfStatus   CardStatus
                }

        fnCPerfID       OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible 
                STATUS  mandatory
                DESCRIPTION
                        "The module ID where the fan module is plugged in."
                ::= { fnCPerfEntry 1 }

        fnCPerfState    OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            fnOK(1),
                            fnDegrade(2),
                            fnFailed(3),
                            fnEmpty(4)
                        }
                ACCESS  not-accessible 
                STATUS  mandatory
                DESCRIPTION
                        "The state of the fan module."
                ::= { fnCPerfEntry 2 }

        fnCPerfStatus   OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  not-accessible 
                STATUS  mandatory
                DESCRIPTION
                        "The status of the fan module.  This status
                         represents the status of the fan module and in general is
                         different from the status of the system."
                ::= { fnCPerfEntry 3 }

        -- The elements in the rpsmCond subgroup of the specialConditions


        rpsmCNumEvents  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         RPSMs' since this mode is started."
                ::= { rpsmCond 1 }


        rpsmCPerfTable  OBJECT-TYPE
                SYNTAX  SEQUENCE OF RpsmCPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each rpsm card"
                ::= { rpsmCond 2 }

        rpsmCPerfEntry  OBJECT-TYPE
                SYNTAX  RpsmCPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { rpsmCPerfLocation, rpsmCPerfShelf, rpsmCPerfSlot }
                ::= { rpsmCPerfTable 1 }

        RpsmCPerfEntry   ::=
                SEQUENCE
                {
                        rpsmCPerfLocation  CardLocation,
                        rpsmCPerfShelf     CardShelf,
                        rpsmCPerfSlot      INTEGER,
                        rpsmCPerfState     CardState,
                        rpsmCPerfStatus    CardStatus,
                        rpsmCAvailTime     Counter,
                        rpsmCErrFreeSecs   Counter
                }

        rpsmCPerfLocation  OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card.  Choices are local or
                         remote."
                ::= { rpsmCPerfEntry 1 }

        rpsmCPerfShelf  OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 10"
                ::= { rpsmCPerfEntry 2 }

        rpsmCPerfSlot   OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { rpsmCPerfEntry 3 }

        rpsmCPerfState  OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The state of the rpsm card.  The states are:
                         online, offline, empty, loopback or diag."
                ::= { rpsmCPerfEntry 4 }

        rpsmCPerfStatus OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The status of the rpsm card.  This status represents
                         the status of the rpsm card and in general is
                         different from the status of the system."
                ::= { rpsmCPerfEntry 5 }

        rpsmCAvailTime  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this rpsm has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { rpsmCPerfEntry 6 }

        rpsmCErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this rpsm has not experienced any alarms."
                ::= { rpsmCPerfEntry 7 }

        rpsmCCounterFlag OBJECT-TYPE
                SYNTAX  FlagType
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Turns special condition software counters On or
                         Off for this card. Default is off."
                ::= { rpsmCond 3}

        -- The elements in the rsdmCond subgroup of the specialConditions

        rsdmCNumEvents  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         RSDMs' since this mode is started."
                ::= { rsdmCond 1 }


        rsdmCPerfTable  OBJECT-TYPE
                SYNTAX  SEQUENCE OF RsdmCPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each oppm card"
                ::= { rsdmCond 2 }

        rsdmCPerfEntry  OBJECT-TYPE
                SYNTAX  RsdmCPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { rsdmCPerfLocation, rsdmCPerfShelf, rsdmCPerfSlot }
                ::= { rsdmCPerfTable 1 }

        RsdmCPerfEntry   ::=
                SEQUENCE
                {
                        rsdmCPerfLocation  CardLocation,
                        rsdmCPerfShelf     CardShelf,
                        rsdmCPerfSlot      INTEGER,
                        rsdmCPerfState     CardState,
                        rsdmCPerfStatus    CardStatus,
                        rsdmCAvailTime     Counter,
                        rsdmCErrFreeSecs   Counter
                }

        rsdmCPerfLocation  OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card.  Choices are local or
                         remote."
                ::= { rsdmCPerfEntry 1 }

        rsdmCPerfShelf  OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 10"
                ::= { rsdmCPerfEntry 2 }

        rsdmCPerfSlot   OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { rsdmCPerfEntry 3 }

        rsdmCPerfState  OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The state of the rsdm card.  The states are:
                         online, offline, empty, loopback or diag."
                ::= { rsdmCPerfEntry 4 }

        rsdmCPerfStatus OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The status of the rsdm card.  This status represents
                         the status of the rsdm card and in general is
                         different from the status of the system."
                ::= { rsdmCPerfEntry 5 }

        rsdmCAvailTime  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this rsdm has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { rsdmCPerfEntry 6 }

        rsdmCErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this rsdm has not experienced any alarms."
                ::= { rsdmCPerfEntry 7 }

        rsdmCCounterFlag OBJECT-TYPE
                SYNTAX  FlagType
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
            "Turns special condition software counters On
             or Off for this card. Default is off."
                ::= { rsdmCond 3}

        -- The elements in the rtdmCond subgroup of the specialConditions

        rtdmCNumEvents  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         RTDM's since this mode is started."
                ::= { rtdmCond 1 }


        rtdmCPerfTable  OBJECT-TYPE
                SYNTAX  SEQUENCE OF RtdmCPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each mux/demux card"
                ::= { rtdmCond 2 }

        rtdmCPerfEntry  OBJECT-TYPE
                SYNTAX  RtdmCPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { rtdmCPerfLocation, rtdmCPerfShelf, rtdmCPerfSlot }
                ::= { rtdmCPerfTable 1 }

        RtdmCPerfEntry   ::=
                SEQUENCE
                {
                        rtdmCPerfLocation  CardLocation,
                        rtdmCPerfShelf     CardShelf,
                        rtdmCPerfSlot      INTEGER,
                        rtdmCPerfState     CardState,
                        rtdmCPerfStatus    CardStatus,
                        rtdmCAvailTime     Counter,
                        rtdmCErrFreeSecs   Counter
                }

        rtdmCPerfLocation  OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card.  Choices are local or
                         remote."
                ::= { rtdmCPerfEntry 1 }

        rtdmCPerfShelf  OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in.  Valid values are: 1 to 10"
                ::= { rtdmCPerfEntry 2 }

        rtdmCPerfSlot   OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { rtdmCPerfEntry 3 }

        rtdmCPerfState  OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The status of the mux card.  The states are:
                         online, offline, empty, loopback or diag."
                ::= { rtdmCPerfEntry 4 }

        rtdmCPerfStatus OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The status of the mux card.  This status represents
                         the status of the mux card and in general is
                         different from the status of the system."
                ::= { rtdmCPerfEntry 5 }

        rtdmCAvailTime  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this Mux has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { rtdmCPerfEntry 6 }

        rtdmCErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this mux has not experienced any alarms."
                ::= { rtdmCPerfEntry 7 }

        rtdmCCounterFlag OBJECT-TYPE
                SYNTAX  FlagType
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Turns special condition software counters On or Off
             for this card. Default is off."
                ::= { rtdmCond 3}


        -- The elements in the osamCond subgroup of the specialConditions

        osamCNumEvents  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total number of events received for all osam's since
                         this mode was started."
                ::= { osamCond 1 }

        osamCPerfTable  OBJECT-TYPE
                SYNTAX  SEQUENCE OF OsamCPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for 
                         special conditions performance data collected for 
                         each osam module."
                ::= { osamCond 2 }

        osamCPerfEntry  OBJECT-TYPE
                SYNTAX  OsamCPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { osamCPerfLocation, osamCPerfShelf, osamCPerfSlot }
                ::= { osamCPerfTable 1 }

        OsamCPerfEntry   ::=
                SEQUENCE
                {
                        osamCPerfLocation           CardLocation,
                        osamCPerfShelf              CardShelf,
                        osamCPerfSlot               INTEGER,
                        osamCPerfState              CardState,
                        osamCPerfStatus             CardStatus,
                        osamCPerfAvailTime          Counter,
                        osamCPerfErrFreeSecs        Counter
                }

        osamCPerfLocation  OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Location of the module."
                ::= { osamCPerfEntry 1 }

        osamCPerfShelf  OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf number in which the module is plugged in."
                ::= { osamCPerfEntry 2 }

        osamCPerfSlot   OBJECT-TYPE
                SYNTAX  INTEGER (1..16)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot number in which the module is plugged in."
                ::= { osamCPerfEntry 3 }

        osamCPerfState  OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The current state of the module."
                ::= { osamCPerfEntry 4 }

        osamCPerfStatus OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The current alarm status of the channel."
                ::= { osamCPerfEntry 5 }

        osamCPerfAvailTime   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds since the start of this mode
                         that this module has been up and running."
                ::= { osamCPerfEntry 6 }

        osamCPerfErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds since the start of this mode
                         that this module has been experienced any alarms."
                ::= { osamCPerfEntry 7 }

        osamCPerfCounterFlag   OBJECT-TYPE
                SYNTAX  FlagType
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Turns osam special condition software counters on
             and off. Default is off."
                ::= { osamCond 3}

        -- The elements in the rsmCond subgroup of the specialConditions

        rsmCNumEvents   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         RSMs' since this mode is started."
                ::= { rsmCond 1 }


        rsmCPerfTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF RsmCPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each rsm card"
                ::= { rsmCond 2 }

        rsmCPerfEntry   OBJECT-TYPE
                SYNTAX  RsmCPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { rsmCPerfLocation, rsmCPerfShelf, rsmCPerfSlot }
                ::= { rsmCPerfTable 1 }

        RsmCPerfEntry   ::=
                SEQUENCE
                {
                        rsmCPerfLocation  CardLocation,
                        rsmCPerfShelf     CardShelf,
                        rsmCPerfSlot      CardSlot,
                        rsmCPerfState     CardState,
                        rsmCPerfStatus    CardStatus,
                        rsmCAvailTime     Counter,
                        rsmCErrFreeSecs   Counter
                }

        rsmCPerfLocation  OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card."
                ::= { rsmCPerfEntry 1 }

        rsmCPerfShelf   OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in."
                ::= { rsmCPerfEntry 2 }

        rsmCPerfSlot    OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { rsmCPerfEntry 3 }

        rsmCPerfState   OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The state of the rsm card.  The states are:
                         online, offline, empty, loopback or diag."
                ::= { rsmCPerfEntry 4 }

        rsmCPerfStatus  OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The status of the rsm card.  This status represents
                         the status of the rsm card and in general is
                         different from the status of the system."
                ::= { rsmCPerfEntry 5 }

        rsmCAvailTime   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this rsm has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { rsmCPerfEntry 6 }

        rsmCErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this rsm has not experienced any alarms."
                ::= { rsmCPerfEntry 7 }

        rsmCCounterFlag OBJECT-TYPE
                SYNTAX  FlagType
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
            "Turns special condition software counters On
             or Off for this card. Default is off."
                ::= { rsmCond 3}

        -- The elements in the upsmCond subgroup of the specialConditions

        upsmCNumEvents  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Total number of all traps (events) generated by all
                         UPSMs' since this mode is started."
                ::= { upsmCond 1 }


        upsmCPerfTable  OBJECT-TYPE
                SYNTAX  SEQUENCE OF UpsmCPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for performance
                         data collected for each upsm card"
                ::= { upsmCond 2 }

        upsmCPerfEntry  OBJECT-TYPE
                SYNTAX  UpsmCPerfEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { upsmCPerfLocation, upsmCPerfShelf, upsmCPerfSlot }
                ::= { upsmCPerfTable 1 }

        UpsmCPerfEntry   ::=
                SEQUENCE
                {
                        upsmCPerfLocation   CardLocation,
                        upsmCPerfShelf      CardShelf,
                        upsmCPerfSlot       CardSlot,
                        upsmCPerfState      CardState,
                        upsmCPerfStatus     CardStatus,
                        upsmCAvailTime      Counter,
                        upsmCErrFreeSecs    Counter
                }

        upsmCPerfLocation  OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card."
                ::= { upsmCPerfEntry 1 }

        upsmCPerfShelf  OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The shelf the card is in."
                ::= { upsmCPerfEntry 2 }

        upsmCPerfSlot   OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The slot within the shelf the card is in."
                ::= { upsmCPerfEntry 3 }

        upsmCPerfState  OBJECT-TYPE
                SYNTAX  CardState
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The state of the upsm card.  The states are:
                         online, offline, empty, loopback or diag."
                ::= { upsmCPerfEntry 4 }

        upsmCPerfStatus OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The status of the upsm card.  This status represents
                         the status of the upsm card and in general is
                         different from the status of the system."
                ::= { upsmCPerfEntry 5 }

        upsmCAvailTime  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this upsm has been up and running.  This will
                         generally be the same as 15 minutes in seconds (900)."
                ::= { upsmCPerfEntry 6 }

        upsmCErrFreeSecs OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The number of seconds in this time slot (15 minutes)
                         that this upsm has not experienced any alarms."
                ::= { upsmCPerfEntry 7 }

        upsmCCounterFlag OBJECT-TYPE
                SYNTAX  FlagType
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Turns special condition software counters On
                         or Off for this card. Default is off."
                ::= { upsmCond 3}

        -- The elements in the eventLog subgroup of the traps

        eveTrapThreshold OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Threshold before events of the same type are no longer
                         sent. Default can be a number as small as 1."
                ::= { eventLog 1 }

        eveNumEvents    OBJECT-TYPE
                SYNTAX  EventBuffer
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of events logged in the table below.  This
                         counter is automatically set by the software."
                ::= { eventLog 2 }

        eveLogTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF EveLogEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for the
                         event log buffer.  There are a maximum of 700
                         entries in the event log.  The events are kept
                         in a circular buffer fashion with eveSeqNum
                         going from 1 to 9999."
                ::= { eventLog 3 }

        eveLogEntry     OBJECT-TYPE
                SYNTAX  EveLogEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { eveDateTime, eveSeqNum }
                ::= { eveLogTable 1 }

        EveLogEntry     ::=
                SEQUENCE
                {
                        eveDateTime             DateAndTime,
                        eveEventId              INTEGER,
                        eveSeverity             TrapStatus,
                        eveSysStatus            CardStatus,
                        eveSource               DisplayString,
                        eveDescr                DisplayString,
                        eveTrap                 Boolean,
                        eveSeqNum               INTEGER
                }

        eveDateTime     OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the event logged in the buffer"
                ::= { eveLogEntry 1 }

        eveEventId      OBJECT-TYPE
                SYNTAX  INTEGER (0..9999)
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The event ID assigned to this event."
                ::= { eveLogEntry 2 }

        eveSeverity     OBJECT-TYPE
                SYNTAX  TrapStatus
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The severity of this event.  Could be critical, major,
                         minor, or normal (informational)."
                ::= { eveLogEntry 3 }

        eveSysStatus    OBJECT-TYPE
                SYNTAX  CardStatus
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The current status of the system.  Could be critical,
                         major, minor, or normal (informational)."
                ::= { eveLogEntry 4 }

        eveSource       OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..152))
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "A five to seven tuple string composed of the
                         following items: System Name:card type (MPM,
                         OCMITU, OFCM, etc.). location (L for local,
                         R[number] for remote with optional station number).
                         shelf #. slot id[. port #][:link name(optional
                         depending on card type)] [:ring name(optional)] [:path name(optional)].
                         When an event applies to all slots of the whole
                         chassis, 0 will be displayed for both shelf and slot.
                         Example: SystemInSunnyvale:OCMITU.L.1.6:ITU23"
                ::= { eveLogEntry 5 }

        eveDescr        OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..100))
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "A string signifying the cause of the error in natural
                         language (preferrably English) format."
                ::= { eveLogEntry 6 }

        eveTrap         OBJECT-TYPE
                SYNTAX  Boolean
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "If set to True, this event was sent as a trap.  If
                         set to False, this event was merely logged and not
                         sent as a trap."
                ::= { eveLogEntry 7 }

        eveSeqNum       OBJECT-TYPE
                SYNTAX  INTEGER (0..9999)
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The unique sequence number for this event entry in
                         the event log."
                ::= { eveLogEntry 8 }

        eveDeleteLog    OBJECT-TYPE
                SYNTAX  ResetType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "If the value is reset, the event log table of the
                         active cp is deleted - meaning all the log entries
                         are flushed!!"
                ::= { eventLog 4 }

        eveLastEntryDateTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Date and time stamp of the last event log entry.  This
                         provides quick access into the last event log entry."
                ::= { eventLog 5 }

        eveHundredthEntryDateTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Date and time stamp of the most recent 100th event
                         log entry.  This provides quick access into
                         retrieving the most recent 100 event log entries.
                         If less than 100 entries exist in the event log,
                         the return value contains all zeroes."
                ::= { eventLog 6 }

        eveTwoHundredthEntryDateTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Date and time stamp of the most recent 200th event
                         log entry.  This provides quick access into
                         retrieving the most recent 200 event log entries.
                         If less than 200 entries exist in the event log,
                         the return value contains all zeroes."
                ::= { eventLog 7 }

        eveThreeHundredthEntryDateTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Date and time stamp of the most recent 300th event
                         log entry.  This provides quick access into
                         retrieving the most recent 300 event log entries.
                         If less than 300 entries exist in the event log,
                         the return value contains all zeroes."
                ::= { eventLog 8 }

        eveFourHundredthEntryDateTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Date and time stamp of the most recent 400th event
                         log entry.  This provides quick access into
                         retrieving the most recent 400 event log entries.
                         If less than 400 entries exist in the event log,
                         the return value contains all zeroes."
                ::= { eventLog 9 }

        eveFiveHundredthEntryDateTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Date and time stamp of the most recent 500th event
                         log entry.  This provides quick access into
                         retrieving the most recent 500 event log entries.
                         If less than 500 entries exist in the event log,
                         the return value contains all zeroes."
                ::= { eventLog 10 }

        eveSixHundredthEntryDateTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Date and time stamp of the most recent 600th event
                         log entry.  This provides quick access into
                         retrieving the most recent 600 event log entries.
                         If less than 600 entries exist in the event log,
                         the return value contains all zeroes."
                ::= { eventLog 11 }

        eveSevenHundredthEntryDateTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Date and time stamp of the most recent 700th event
                         log entry.  This provides quick access into
                         retrieving the most recent 700 event log entries.
                         If less than 700 entries exist in the event log,
                         the return value contains all zeroes."
                ::= { eventLog 12 }

        eveEightHundredthEntryDateTime    OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Date and time stamp of the most recent 800th event
                         log entry.  This provides quick access into
                         retrieving the most recent 800 event log entries.
                         If less than 800 entries exist in the event log,
                         the return value contains all zeroes."
                ::= { eventLog 13 }

        eveNineHundredthEntryDateTime    OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Date and time stamp of the most recent 900th event
                         log entry.  This provides quick access into
                         retrieving the most recent 900 event log entries.
                         If less than 900 entries exist in the event log,
                         the return value contains all zeroes."
                ::= { eventLog 14 }

        -- The elements in the userLog subgroup of the traps

        usrNumLogs      OBJECT-TYPE
                SYNTAX  UserBuffer
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Number of user events logged in the table below.  This
                         counter is automatically set by the software."
                ::= { userLog 1 }

        usrLogTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF UsrLogEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for user event
                         log buffer"
                ::= { userLog 2 }

        usrLogEntry     OBJECT-TYPE
                SYNTAX  UsrLogEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { usrDateTime, usrLogonId }
                ::= { usrLogTable 1 }

        UsrLogEntry     ::=
                SEQUENCE
                {
                        usrDateTime             DateAndTime,
                        usrLogonId              LogonID,
                        usrTarget               DisplayString (SIZE (0..30)),
                        usrLogDescr             DisplayString (SIZE (0..100)),
                        usrTrap                 Boolean
                }

        usrDateTime     OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The date and time of the event logged in the buffer"
                ::= { usrLogEntry 1 }

        usrLogonId      OBJECT-TYPE
                SYNTAX  LogonID
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The Logon ID of the user causing this event to be
                         logged."
                ::= { usrLogEntry 2 }

        usrTarget       OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..30))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "A four tuple string composed of the following items:
                         location (remote or local), type (cp, cc, mux or ps),
                         shelf, and slot id.  The tuples are separated by
                         comma.  Example: local,cp,b,1.  This column identifies
                         which subsystem was affected by the user action."
                ::= { usrLogEntry 3 }

        usrLogDescr     OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..100))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "A string signifying the action logged in natural
                         language (preferrably English) format."
                ::= { usrLogEntry 4 }

        usrTrap         OBJECT-TYPE
                SYNTAX  Boolean
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "If set to True, this user event was sent as a trap.
                         If set to False, this event was merely logged and not
                         sent as a trap."
                ::= { usrLogEntry 5 }

        -- The elements in the alarmLog subgroup of the faults group


        alarmNumEvents  OBJECT-TYPE
                SYNTAX  INTEGER(0..300)
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of alarms logged in the table below.  This
                         counter is automatically set by the software. The max
                         is 300 entries."
                ::= { alarmLog 1}

        alarmLogTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF AlarmLogEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for the alarm
                         log buffer"
                ::= { alarmLog 2 }

        alarmLogEntry   OBJECT-TYPE
                SYNTAX  AlarmLogEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { alarmFirstDateTime, alarmTag }
                ::= { alarmLogTable 1 }

        AlarmLogEntry   ::=
                SEQUENCE
                {
                    alarmFirstDateTime  DateAndTime,
                    alarmTag            INTEGER,
                    alarmLastDateTime   DateAndTime,
                    alarmEventId        INTEGER,
                    alarmSeverity       INTEGER,
                    alarmSource         DisplayString,
                    alarmDescr          DisplayString,
                    alarmCnt            INTEGER,
                    alarmAck            INTEGER,
                    alarmClear          INTEGER
                }

        alarmFirstDateTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time for the first alarm occurrence."
                ::= { alarmLogEntry 1 }

        alarmTag        OBJECT-TYPE
                SYNTAX  INTEGER(1..999)
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "A unique tag used to identify the alarm entry."
                ::= { alarmLogEntry 2 }

        alarmLastDateTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The date and time for the most recent alarm occurrence.
                         If this is the first time occurrence, it would be same
                         as alarmFirstDateTime."
                ::= { alarmLogEntry 3 }

        alarmEventId    OBJECT-TYPE
                SYNTAX  INTEGER (0..9999)
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The event ID assigned to this alarm."
                ::= { alarmLogEntry 4 }

        alarmSeverity   OBJECT-TYPE
                SYNTAX  INTEGER { critical(1), major(2), minor(3) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The severity of this alarm.  Could be critical, major,
                         or minor."
                ::= { alarmLogEntry 5 }


        alarmSource     OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..152))
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "A five to seven tuple string composed of the
                         following items: System Name:card type (MPM,
                         OCMITU, OFCM, etc.). location (L for local,
                         R[number] for remote with optional station number).
                         shelf #. slot id[. port #][:link name(optional
                         depending on card type)][:ring name (optional)]
                         [:pathname(optional)].
                         When an event applies to all slots of the whole
                         chassis, 0 will be displayed for both shelf and slot.
                         Example: SystemInSunnyvale:OCMITU.L.1.6:ITU23"
                ::= { alarmLogEntry 6 }

        alarmDescr      OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..100))
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "A string signifying the cause of the error in natural
                         language (preferrably English) format."
                ::= { alarmLogEntry 7 }

        alarmCnt        OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of times alarm has occurred(from the same source)."
                ::= { alarmLogEntry 8 }

        alarmAck        OBJECT-TYPE
                SYNTAX  INTEGER { acknowledged(1), unacknowledged(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Acknowledge or unacknowledge the active alarm. Ack will
                         remove its contribution to the external dry contact alarm
                         closure. Default is unacknowledged."
                ::= { alarmLogEntry  9 }

        alarmClear      OBJECT-TYPE
                SYNTAX  INTEGER { other(1), clear(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "An action to clear the alarm from the alarm log. If
                         alarm persists, another alarm will be sent. A GET
                         operation would always return other(1)."
                ::= { alarmLogEntry  10 }

        alarmLastChange OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Time ticks in microseconds of when the last change
                         was made to the alarm log.  This includes ack/unack,
                         clear, and alarm addition/deletion."
                ::= { alarmLog 3}

        -- The elements in the diagnostics subgroup of the traps

        diagModeNum     OBJECT-TYPE
                SYNTAX  INTEGER (0..128)
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of cards in diagnostics mode in the table
                         below.  This counter is automatically set by the
                         software."
                ::= { diagnostics 1 }

        diagModeTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF DiagModeEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each card
                         in diagnostics mode."
                ::= { diagnostics 2 }

        diagModeEntry   OBJECT-TYPE
                SYNTAX  DiagModeEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { diagLocation, diagShelf, diagSlot }
                ::= { diagModeTable 1 }

        DiagModeEntry   ::=
                SEQUENCE
                {
                        diagLocation            CardLocation,
                        diagShelf               CardShelf,
                        diagSlot                INTEGER,
                        diagSetMode             INTEGER
                }

        diagLocation    OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card: local or remote"
                ::= { diagModeEntry 1 }

        diagShelf       OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The shelf in which the card is located."
                ::= { diagModeEntry 2 }

        diagSlot        OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The card slot in which the card is located."
                ::= { diagModeEntry 3 }

        diagSetMode     OBJECT-TYPE
                SYNTAX  INTEGER 
                        {
                            other(1),
                            warmboot(2),
                            loopbackDisabled(3),
                            loopbackEnabled(4),
                            selftest(5)
                        }                
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "If on, the card will be in diagnostics mode.  If
                         off, the card comes out of diagnostics mode."
                ::= { diagModeEntry 4 }

        diagTestNum     OBJECT-TYPE
                SYNTAX  INTEGER (0..20)
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of built-in diagnostics tests in the table
                         below."
                ::= { diagnostics 3 }

        diagTestTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF DiagTestEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         built-in diagnostics test."
                ::= { diagnostics 4 }

        diagTestEntry   OBJECT-TYPE
                SYNTAX  DiagTestEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { diagTestId, diagTLocation, diagTShelf, diagTSlot }
                ::= { diagTestTable 1 }

        DiagTestEntry   ::=
                SEQUENCE
                {
                        diagTestId              INTEGER,
                        diagTLocation           CardLocation,
                        diagTShelf              CardShelf,
                        diagTSlot               INTEGER,
                        diagParam1              DisplayString (SIZE (0..30)),
                        diagParam2              DisplayString (SIZE (0..30)),
                        diagParam3              DisplayString (SIZE (0..30)),
                        diagTSetMode            FlagType
                }

        diagTestId      OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            lLoopBack(1),
                            rLoopBack(2),
                            lNormal(3),
                            rNormal(4)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The name of the built-in diagnostics test."
                ::= { diagTestEntry 1 }

        diagTLocation   OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card to run the test on"
                ::= { diagTestEntry 2 }

        diagTShelf      OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The shelf in which the card is located."
                ::= { diagTestEntry 3 }

        diagTSlot       OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The card slot in which the card is located."
                ::= { diagTestEntry 4 }

        diagParam1      OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..30))
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The first parameter, if any to pass to the built-in
                         test module.  This parameter may be NULL to signify
                         no run-time parameters.  If there is a parameter in,
                         any data type, it should be passed as a String
                         equivalent."
                ::= { diagTestEntry 5 }

        diagParam2      OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..30))
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The second parameter, if any to pass to the built-in
                         test module.  This parameter may be NULL to signify
                         no more run-time parameters.  If there is a parameter
                         in any data type, it should be passed as a String
                         equivalent."
                ::= { diagTestEntry 6 }

        diagParam3      OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..30))
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The third parameter, if any to pass to the built-in
                         test module.  This parameter may be NULL to signify
                         no more run-time parameters.  If there is a parameter
                         in any data type, it should be passed as a String
                         equivalent."
                ::= { diagTestEntry 7 }

        diagTSetMode    OBJECT-TYPE
                SYNTAX  FlagType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "If on, the given test will be run on the given card.
                         The value off has no effect in this case and is
                         ignored."
                ::= { diagTestEntry 8 }

        mcmescSelfTestTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF McmescSelfTestEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the self-test results for mcmesc link port."
                ::= { mcmescSelfTest 1 }

        mcmescSelfTestEntry OBJECT-TYPE
                SYNTAX  McmescSelfTestEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { mcmescSelfTestLocation, mcmescSelfTestShelf, mcmescSelfTestSlot }
                ::= { mcmescSelfTestTable 1 }

        
        McmescSelfTestEntry ::=
                SEQUENCE
                {
                        mcmescSelfTestLocation  CardLocation,
                        mcmescSelfTestShelf     CardShelf,
                        mcmescSelfTestSlot      INTEGER,
                        mcmescSelfTestStart     INTEGER,
                        mcmescSelfTestResult    INTEGER,    
                        mcmescSelfTestSeqNum    DisplayString,
                        mcmescSelfTestTimeStamp DisplayString
                }

        mcmescSelfTestLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card: local or remote. The self test
                         is applicable to local mcmesc only."
                ::= { mcmescSelfTestEntry 1 }

        mcmescSelfTestShelf OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The shelf in which the card is located."
                ::= { mcmescSelfTestEntry 2 }

        mcmescSelfTestSlot OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The card slot in which the card is located."
                ::= { mcmescSelfTestEntry 3 }

        mcmescSelfTestStart OBJECT-TYPE
                SYNTAX  INTEGER { other(1), yes(2) }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Initiate a self-test. A get on this will always return an other.
                         Any outstanding loopbacks will be turned off before starting
                         self-test."
                ::= { mcmescSelfTestEntry 4 }

        mcmescSelfTestResult OBJECT-TYPE
                SYNTAX  INTEGER { passed(1), failed(2), inprogress(3),  notreported(4) }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Indicate an overall result of the latest self-test.
                         The value inprogress(3) will be given if a self-test is in progress.
                         The table mcmescLinkSelfTestResult and mcmescPortSelfTestResult
                         show the detail result of each individual test item."
                ::= { mcmescSelfTestEntry 5 }

        mcmescSelfTestSeqNum OBJECT-TYPE
                SYNTAX  DisplayString 
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Indicate a sequece number associated with the latest 
                         complete self test.
                         The sring of inprogress will be given if a self-test is in progress.
                         The table mcmescLinkSelfTestResult and mcmescPortSelfTestResult
                         show the detail result of each individual test item."
                ::= { mcmescSelfTestEntry 6 }

        mcmescSelfTestTimeStamp OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Indicate the time stamp associated with the latest 
                         complete self test.
                         The value inprogress(3) will be given if a self-test is in progress.
                         The table mcmescLinkSelfTestResult and mcmescPortSelfTestResult
                         show the detail result of each individual test item."
                ::= { mcmescSelfTestEntry 7 }

        mcmescLinkSelfTestResultTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF McmescLinkSelfTestResultEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the self-test results for mcmesc link port."
                ::= { mcmescSelfTest 2 }

        mcmescLinkSelfTestResultEntry OBJECT-TYPE
                SYNTAX  McmescLinkSelfTestResultEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { mcmescLinkSelfTestLocation, mcmescLinkSelfTestShelf, mcmescLinkSelfTestSlot }
                ::= { mcmescLinkSelfTestResultTable 1 }

        
        McmescLinkSelfTestResultEntry ::=
                SEQUENCE
                {
                        mcmescLinkSelfTestLocation  CardLocation,
                        mcmescLinkSelfTestShelf     CardShelf,
                        mcmescLinkSelfTestSlot      INTEGER,
                        mcmescLinkSelfTestTxI2c     INTEGER,
                        mcmescLinkSelfTestCdrI2c    INTEGER,
                        mcmescLinkSelfTestDataPath  INTEGER
                }

        mcmescLinkSelfTestLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card: local or remote. The self test
                         is applicable to local mcmesc only."
                ::= { mcmescLinkSelfTestResultEntry 1 }

        mcmescLinkSelfTestShelf OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The shelf in which the card is located."
                ::= { mcmescLinkSelfTestResultEntry 2 }

        mcmescLinkSelfTestSlot OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The card slot in which the card is located."
                ::= { mcmescLinkSelfTestResultEntry 3 }

        mcmescLinkSelfTestTxI2c OBJECT-TYPE
                SYNTAX  INTEGER { passed(1), failed(2), inprogress(3), notreported(4) }                
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Indicate the link port's Tx I2C self-test result.
                         The value inprogress(3) will be given if a self-test is in progress."
                ::= { mcmescLinkSelfTestResultEntry 4 }

        mcmescLinkSelfTestCdrI2c OBJECT-TYPE
                SYNTAX  INTEGER { passed(1), failed(2), inprogress(3), notreported(4) }                
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Indicate the link port's CDR I2C self-test result.
                         The value inprogress(3) will be given if a self-test is in progress."
                ::= { mcmescLinkSelfTestResultEntry 5 }

        mcmescLinkSelfTestDataPath OBJECT-TYPE
                SYNTAX  INTEGER { passed(1), failed(2), inprogress(3), notreported(4) }                
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Indicate the link port's data path self-test result.
                         The value inprogress(3) will be given if a self-test is in progress."
                ::= { mcmescLinkSelfTestResultEntry 6 }

        mcmescPortSelfTestResultTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF McmescPortSelfTestResultEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the self-test results for mcmesc CPE port."
                ::= { mcmescSelfTest 3 }

        mcmescPortSelfTestResultEntry   OBJECT-TYPE
                SYNTAX  McmescPortSelfTestResultEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { mcmescPortSelfTestLocation, mcmescPortSelfTestShelf, 
                          mcmescPortSelfTestSlot, mcmescPortSelfTestPort}
           
                ::= { mcmescPortSelfTestResultTable 1 }

        
        McmescPortSelfTestResultEntry ::=
                SEQUENCE
                {
                        mcmescPortSelfTestLocation      CardLocation,
                        mcmescPortSelfTestShelf         CardShelf,
                        mcmescPortSelfTestSlot          INTEGER,
                        mcmescPortSelfTestPort          INTEGER,
                        mcmescPortSelfTestTxI2c         INTEGER,
                        mcmescPortSelfTestCdrI2c        INTEGER,
                        mcmescPortSelfTestTxDataPath    INTEGER,
                        mcmescPortSelfTestRxDataPath    INTEGER
                }

        mcmescPortSelfTestLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The location of the card: local or remote. The self test
                         is applicable to local mcmesc only."
                ::= { mcmescPortSelfTestResultEntry 1 }

        mcmescPortSelfTestShelf OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The shelf in which the card is located."
                ::= { mcmescPortSelfTestResultEntry 2 }

        mcmescPortSelfTestSlot OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The card slot in which the card is located."
                ::= { mcmescPortSelfTestResultEntry 3 }

        mcmescPortSelfTestPort OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "The CPE port's index."
                ::= { mcmescPortSelfTestResultEntry 4 }

        mcmescPortSelfTestTxI2c OBJECT-TYPE
                SYNTAX  INTEGER { passed(1), failed(2), inprogress(3), notreported(4) }                
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Indicate the CPE port's Tx I2C self-test result.
                         The value inprogress(3) will be given if a self-test is in progress."
                ::= { mcmescPortSelfTestResultEntry 5 }

        mcmescPortSelfTestCdrI2c OBJECT-TYPE
                SYNTAX  INTEGER { passed(1), failed(2), inprogress(3), notreported(4) }                
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Indicate the CPE port's CDR I2C self-test result.
                         The value inprogress(3) will be given if a self-test is in progress."
                ::= { mcmescPortSelfTestResultEntry 6 }

        mcmescPortSelfTestTxDataPath OBJECT-TYPE
                SYNTAX  INTEGER { passed(1), failed(2), inprogress(3), notreported(4) }                
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Indicate the CPE port's Tx data path self-test result.
                         The value inprogress(3) will be given if a self-test is in progress."
                ::= { mcmescPortSelfTestResultEntry 7 }

        mcmescPortSelfTestRxDataPath OBJECT-TYPE
                SYNTAX  INTEGER { passed(1), failed(2), inprogress(3), notreported(4) }                
                ACCESS  read-only 
                STATUS  mandatory
                DESCRIPTION
                        "Indicate the CPE port's Rx data path self-test result.
                         The value inprogress(3) will be given if a self-test is in progress."
                ::= { mcmescPortSelfTestResultEntry 8 }

        -- The elements in the userSecMgmt subgroup of the Security group

        usrNumUsers     OBJECT-TYPE
                SYNTAX  INTEGER (0..999)
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Number of user Logons in the table below.  This
                         counter is automatically set by the software."
                ::= { userSecMgmt 1 }

        usrSecTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF UsrSecEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each user
                         logon entry."
                ::= { userSecMgmt 2 }

        usrSecEntry     OBJECT-TYPE
                SYNTAX  UsrSecEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { usrSecLogonId }
                ::= { usrSecTable 1 }

        UsrSecEntry     ::=
                SEQUENCE
                {
                        usrSecLogonId           LogonID,
                        usrSecPasswd            HashedPasswd,
                        usrSecRole              INTEGER,
                        usrSecFullName          DisplayString (SIZE (0..45)),
                        usrSecActDateTime       DateAndTime,
                        usrSecLastDateTime      DateAndTime,
                        usrSecSetLastDateTime   ResetType
                }

        usrSecLogonId   OBJECT-TYPE
                SYNTAX  LogonID
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The unique logon ID assigned to each user.  This field
                         should only be written by users that are in the right
                         security role."
                ::= { usrSecEntry 1 }

        usrSecPasswd    OBJECT-TYPE
                SYNTAX  HashedPasswd
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The hashed password for each unique logon ID.  To
                         turn the user account off, typically the password
                         is set to some fixed value.  Fixed passwords are
                         not accepted as valid passwords.  Since this field
                         is one-way hashed, it can be safely read without
                         compromising the security of the system."
                ::= { usrSecEntry 2 }

        usrSecRole      OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The role associated with each user logon ID.  This is
                         an index into the system role(s) table."
                ::= { usrSecEntry 3 }

        usrSecFullName  OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..45))
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The full name of the user associated with each unique
                         logon ID."
                ::= { usrSecEntry 4 }

        usrSecActDateTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The Time & Date of the user account activation."
                ::= { usrSecEntry 5 }

        usrSecLastDateTime OBJECT-TYPE
                SYNTAX  DateAndTime
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The Time & Date of the last user logon to the system"
                ::= { usrSecEntry 6 }

        usrSecSetLastDateTime OBJECT-TYPE
                SYNTAX  ResetType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "An action to set the Time & Date of the last user
                         logon to the current systemtime."
                ::= { usrSecEntry 7 }

        -- The elements in the systemSecMgmt subgroup of the Security group

        secNumRoles     OBJECT-TYPE
                SYNTAX  INTEGER (0..9999)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Number of system security roles in the table below.
                         This counter is automatically set by the software."
                ::= { systemSecMgmt 1 }

        secRoleTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF SecRoleEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         system security role entry."
                ::= { systemSecMgmt 2 }

        secRoleEntry    OBJECT-TYPE
                SYNTAX  SecRoleEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { secRole }
                ::= { secRoleTable 1 }

        SecRoleEntry    ::=
                SEQUENCE
                {
                        secRole                 EntityName,
                        secRoleDescr            DisplayString (SIZE (0..60))
                }

        secRole         OBJECT-TYPE
                SYNTAX  EntityName
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Each row in this table defines a unique security
                         role."
                ::= { secRoleEntry 1 }

        secRoleDescr    OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..60))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The full narrated description of each security Role."
                ::= { secRoleEntry 2 }

        secNumGroups    OBJECT-TYPE
                SYNTAX  INTEGER (0..9999)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Number of entity groups in the table below.
                         This counter is automatically set by the software."
                ::= { systemSecMgmt 3 }

        secGroupTable   OBJECT-TYPE
                SYNTAX  SEQUENCE OF SecGroupEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entity group entry."
                ::= { systemSecMgmt 4 }

        secGroupEntry   OBJECT-TYPE
                SYNTAX  SecGroupEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { secGroup, secGroupRole }
                ::= { secGroupTable 1 }

        SecGroupEntry   ::=
                SEQUENCE
                {
                        secGroup                EntityName,
                        secGroupRole            EntityName
                }

        secGroup        OBJECT-TYPE
                SYNTAX  EntityName
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Each row in this table defines a grouping of entities
                         or elements from the MIB."
                ::= { secGroupEntry 1 }

        secGroupRole    OBJECT-TYPE
                SYNTAX  EntityName
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The containment of this group within a security role.
                         Under the given schema, each Role may have zero or
                         more entity groups.  Given an entity group, it may
                         have been contained within one or more roles."
                ::= { secGroupEntry 2 }

        secNumElements  OBJECT-TYPE
                SYNTAX  INTEGER (0..9999)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Number of elements or entities in the table below.
                         This counter is automatically set by the software."
                ::= { systemSecMgmt 5 }

        secElementTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF SecElementEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         entity or element in the MIB."
                ::= { systemSecMgmt 6 }

        secElementEntry OBJECT-TYPE
                SYNTAX  SecElementEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { secElement }
                ::= { secElementTable 1 }

        SecElementEntry ::=
                SEQUENCE
                {
                        secElement              EntityName,
                        secElementAccess        INTEGER,
                        secElementOID           DisplayString (SIZE (0..30)),
                        secElementType          INTEGER,
                        secElementParent        EntityName
                }

        secElement      OBJECT-TYPE
                SYNTAX  EntityName
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Each row in this table defines an element or entity
                         from the MIB."
                ::= { secElementEntry 1 }

        secElementAccess OBJECT-TYPE
                SYNTAX  INTEGER { read(1), write(2), readWrite(3), none(4) }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The original access mode for this element from the
                         MIB."
                ::= { secElementEntry 2 }

        secElementOID   OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..30))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The original SNMP OID for this element from the
                         MIB."
                ::= { secElementEntry 3 }

        secElementType  OBJECT-TYPE
                SYNTAX  INTEGER { element(1), group(2), table(3) }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The original type for this element from the
                         MIB."
                ::= { secElementEntry 4 }

        secElementParent OBJECT-TYPE
                SYNTAX  EntityName
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The original parent name for this element from the
                         MIB.  The parent is either a table or a subgroup."
                ::= { secElementEntry 5 }

        secNumElmntGrp  OBJECT-TYPE
                SYNTAX  INTEGER (0..9999)
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Number of element-to-group mappings in the table
                         below. This counter is automatically set by the
                         software."
                ::= { systemSecMgmt 7 }

        secElmntGrpTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF SecElmntGrpEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         element-to-group mapping."
                ::= { systemSecMgmt 8 }

        secElmntGrpEntry OBJECT-TYPE
                SYNTAX  SecElmntGrpEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX { elmntName, grpName }
                ::= { secElmntGrpTable 1 }

        SecElmntGrpEntry ::=
                SEQUENCE
                {
                        elmntName               EntityName,
                        grpName                 EntityName,
                        elmntGrpAccess          INTEGER
                }

        elmntName       OBJECT-TYPE
                SYNTAX  EntityName
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Each row in this table defines a mapping of elements
                         to groups.  This column is an index into the
                         secElementTable."
                ::= { secElmntGrpEntry 1 }

        grpName         OBJECT-TYPE
                SYNTAX  EntityName
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Each row in this table defines a mapping of elements
                         to groups.  This column is an index into the
                         secGroupTable."
                ::= { secElmntGrpEntry 2 }

        elmntGrpAccess  OBJECT-TYPE
                SYNTAX  INTEGER { read(1), write(2), readWrite(3), none(4) }
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The access mode assigned to each element/group entry.
                         Under the given schema, each group may have zero or
                         more MIB elements.  Given an element, it may
                         have been contained within one or more groups.  The
                         access mode specified here defines what is the granted
                         access mode to the named element contained in this
                         group.  Note, the granted access right can never
                         exceed that of the actual MIB access privilege."
                ::= { secElmntGrpEntry 3 }

        -- The elements in the radiusSecMgmt subgroup of the Security group

        radiusAuthOrder   OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            local(1),
                            radius(2),
                            localRadius(3),
                            radiusLocal(4)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The authentication order used when validating a user
                         login id and password."
                ::= { radiusSecMgmt 1 }

        radiusNasIdentifier   OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..32))
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "NAS-Identifier for the MPM."
                ::= { radiusSecMgmt 2 }

        radiusDefaultRealm   OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (0..32))
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Default realm used for radius authentication.  This
                         realm is not used for local authentication."
                ::= { radiusSecMgmt 3 }

        radiusTimeout   OBJECT-TYPE
                SYNTAX  INTEGER (1..60)
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Timeout when sending an authentication request to
                         a radius server."
                ::= { radiusSecMgmt 4 }

        radiusRetries   OBJECT-TYPE
                SYNTAX  INTEGER (1..10)
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Number of times to resend requests when a timeout
                         occurs."
                ::= { radiusSecMgmt 5 }

        radiusSecTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF RadiusSecEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Radius server table."
                ::= { radiusSecMgmt 6 }

        radiusSecEntry     OBJECT-TYPE
                SYNTAX  RadiusSecEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { radiusServerIndex }
                ::= { radiusSecTable 1 }

        RadiusSecEntry     ::=
                SEQUENCE
                {
                        radiusServerIndex       INTEGER,
                        radiusServerAddress     IpAddress,
                        radiusServerPort        INTEGER,
                        radiusServerSecret      DisplayString
                }

        radiusServerIndex   OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "Index into the radius server table.  This index also
                         specifies the server order used for sending authentication
                         requests."
                ::= { radiusSecEntry 1 }

        radiusServerAddress    OBJECT-TYPE
                SYNTAX  IpAddress
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "IP address of the radius server.  Setting the address to
                         0 will delete the server entry."
                ::= { radiusSecEntry 2 }

        radiusServerPort      OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Radius port used for authentication requests."
                ::= { radiusSecEntry 3 }

        radiusServerSecret  OBJECT-TYPE
                SYNTAX  DisplayString (SIZE (1..48))
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Secret shared with authentication server."
                ::= { radiusSecEntry 4 }

        radiusAddServer   OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Add server to the server table.  Servers are added 
                         to the first available entry in the server table. To
                         add a server provide server IP address, radius port, 
                         and shared secret in the format '<ip address>,<port>,
                         <secret>'.  All fields are required.  a get on this 
                         element will return '0,0,0'."
                ::= { radiusSecMgmt 7 }


        -- The elements in the sshSecMgmt subgroup of the Security group

        sshMode   OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            enabled(1),
                            disabled(2)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Enables or disables the SSH server.  Enabling
                         SSH will disable the built in telnet server.
                         Disabling SSH will enable the telnet server."
                ::= { sshSecMgmt 1 }

        sshKeySize   OBJECT-TYPE
                SYNTAX  INTEGER (512..1024)
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The size (in bits) of the DSS key to generate.
                         Key size must be a multiple of 8 and between 512 
                         and 1024 bits."
                ::= { sshSecMgmt 2 }

        sshMaxSessions   OBJECT-TYPE
                SYNTAX  INTEGER (1..6)
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "The maximum number of SSH sessions that can be
                         active at one time.  Setting this element will
                         also affect the number of telnet sessions that
                         can be active at a time."
                ::= { sshSecMgmt 3 }

        sshGenKey   OBJECT-TYPE
                SYNTAX  INTEGER
                        {
                            other(1),
                            genDssKey(2)
                        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "Setting this element to genDssKey(2) will cause a
                         new DSS key to be generated.  The process of
                         generating a new key can take some time (several 
                         minutes) and may cause significant system slowdown
                         until the process is complete. Reading this element
                         will always return other(1)."
                ::= { sshSecMgmt 4 }

        -- The elements in the cpAcct subgroup of the accounting group

        acctCPTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF AcctCPEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         system accounting data maintained for each CP."
                ::= { cpAcct 1 }

        acctCPEntry     OBJECT-TYPE
                SYNTAX  AcctCPEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { acctCPShelf, acctCPSlot }
                ::= { acctCPTable 1 }

        AcctCPEntry     ::=
                SEQUENCE
                {
                        acctCPShelf             CardShelf,
                        acctCPSlot              INTEGER,
                        acctCPDsgnAct           Counter,
                        acctCPDsgnStdby         Counter,
                        acctCPActive            Counter,
                        acctCPStandby           Counter,
                        acctCPUpTime            Counter,
                        acctCPUnAvail           Counter,
                        acctCPResetCntrs        ResetType
                }

        acctCPShelf     OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf in which the given CP card is placed."
                ::= { acctCPEntry 1 }

        acctCPSlot      OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot in which the given CP card is placed."
                ::= { acctCPEntry 2 }

        acctCPDsgnAct   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The total time this CP has been designated Active"
                ::= { acctCPEntry 3 }

        acctCPDsgnStdby OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "The total time this CP has been designated Standby"
                ::= { acctCPEntry 4 }

        acctCPActive    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The total time this CP has actually been the primary"
                ::= { acctCPEntry 5 }

        acctCPStandby   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The total time this CP has actually been the standby"
                ::= { acctCPEntry 6 }

        acctCPUpTime    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The total time since this CP has been commissioned"
                ::= { acctCPEntry 7 }

        acctCPUnAvail   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The total time this CP has not been available due
                         to an alarm, diag testing or being put offline"
                ::= { acctCPEntry 8 }

        acctCPResetCntrs OBJECT-TYPE
                SYNTAX  ResetType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "If reset, the CP accounting counters will be reset to 0.
                         A get on this will always return other."
                ::= { acctCPEntry 9 }

        -- The elements in the ccAcct subgroup of the accounting group

        acctCCTable     OBJECT-TYPE
                SYNTAX  SEQUENCE OF AcctCCEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         system accounting data maintained for each CC."
                ::= { ccAcct 1 }

        acctCCEntry     OBJECT-TYPE
                SYNTAX  AcctCCEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { acctCCLocation, acctCCShelf, acctCCSlot }
                ::= { acctCCTable 1 }

        AcctCCEntry     ::=
                SEQUENCE
                {
                        acctCCLocation          CardLocation,
                        acctCCShelf             CardShelf,
                        acctCCSlot              INTEGER,
                        acctCCUpTime            Counter,
                        acctCCUnAvail           Counter,
                        acctCCResetCntrs        ResetType
                }

        acctCCLocation  OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the CC card: local or remote."
                ::= { acctCCEntry 1 }

        acctCCShelf     OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf in which the given CC card is placed."
                ::= { acctCCEntry 2 }

        acctCCSlot      OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot in which the given CC card is placed."
                ::= { acctCCEntry 3 }

        acctCCUpTime    OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The total time since this CC has been commissioned"
                ::= { acctCCEntry 4 }

        acctCCUnAvail   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The total time this CC has not been available due
                         to an alarm, diag testing or being put offline"
                ::= { acctCCEntry 5 }

        acctCCResetCntrs OBJECT-TYPE
                SYNTAX  ResetType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "If reset, the CC accounting counters will be reset to 0.
                         A get on this will always return other."
                ::= { acctCCEntry 6 }

        -- The elements in the mcmAcct subgroup of the accounting group

        acctmcmTable    OBJECT-TYPE
                SYNTAX  SEQUENCE OF AcctmcmEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         system accounting data maintained for each MCMT1/MCME1."
                ::= { mcmAcct 1 }

        acctmcmEntry     OBJECT-TYPE
                SYNTAX  AcctmcmEntry 
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { acctmcmLocation, acctmcmShelf, acctmcmSlot }
                ::= { acctmcmTable 1 }

        AcctmcmEntry    ::=
                SEQUENCE
                {
                        acctmcmLocation         CardLocation,
                        acctmcmShelf            CardShelf,
                        acctmcmSlot             INTEGER,
                        acctmcmUpTime           Counter,
                        acctmcmUnAvail          Counter,
                        acctmcmResetCntrs       ResetType
                }

        acctmcmLocation  OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the MCMT1/MCME1 card: local or remote."
                ::= { acctmcmEntry 1 }

        acctmcmShelf    OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf in which the given MCMT1/MCME1 card is placed."
                ::= { acctmcmEntry 2 }

        acctmcmSlot     OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot in which the given MCMT1/MCME1 card is placed."
                ::= { acctmcmEntry 3 }

        acctmcmUpTime   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The total time since this MCMT1/MCME1 has been commissioned"
                ::= { acctmcmEntry 4 }

        acctmcmUnAvail  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The total time this MCMT1/MCME1 has not been available due
                         to an alarm, diag testing or being put offline"
                ::= { acctmcmEntry 5 }

        acctmcmResetCntrs OBJECT-TYPE
                SYNTAX  ResetType
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION
                        "If reset, the MCMT1/MCME1 accounting counters will be
                         reset to 0. A get on this will always
                         return other."
                ::= { acctmcmEntry 6 }

        -- The elements in the mcmescAcct subgroup of the accounting group

        acctmcmescTable OBJECT-TYPE
                SYNTAX  SEQUENCE OF AcctmcmescEntry
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "This table represents the information for each
                         system accounting data maintained for each MCMESC."
                ::= { mcmescAcct 1 }

        acctmcmescEntry OBJECT-TYPE
                SYNTAX  AcctmcmescEntry 
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION
                        "Specifies the index for each row in the table below"
                INDEX   { acctmcmescLocation, acctmcmescShelf, acctmcmescSlot }
                ::= { acctmcmescTable 1 }

        AcctmcmescEntry ::=
                SEQUENCE
                {
                        acctmcmescLocation      CardLocation,
                        acctmcmescShelf         CardShelf,
                        acctmcmescSlot          INTEGER,
                        acctmcmescUpTime        Counter,
                        acctmcmescUnAvail       Counter,
                        acctmcmescResetCntrs    ResetType
                }

        acctmcmescLocation OBJECT-TYPE
                SYNTAX  CardLocation
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The location of the MCMESC card: local or remote."
                ::= { acctmcmescEntry 1 }

        acctmcmescShelf OBJECT-TYPE
                SYNTAX  CardShelf
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The shelf in which the given MCMESC card is placed."
                ::= { acctmcmescEntry 2 }

        acctmcmescSlot  OBJECT-TYPE
                SYNTAX  CardSlot
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The slot in which the given MCMESC card is placed."
                ::= { acctmcmescEntry 3 }

        acctmcmescUpTime OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The total time since this MCMESC has been commissioned."
                ::= { acctmcmescEntry 4 }

        acctmcmescUnAvail OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION
                        "The total time this MCMESC has not been available due
                         to an alarm, diag testing or being put offline."
                ::= { acctmcmescEntry 5 }

        acctmcmescResetCntrs OBJECT-TYPE
                SYNTAX  ResetType
                ACCESS  read-only                
                STATUS  mandatory
                DESCRIPTION
                        "If reset, the MCMESC accounting counters will be reset to 0. A get 
                         on this will always return other."
                ::= { acctmcmescEntry 6 }

        -- The Generic Trap supported by the LuxN MIB.

        luxNGenericTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This is a generic trap identifying an event for
                     a given event source.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 1

        luxNVoadmDetectorFailureTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a failure is detected on the
                     VOADM power monitor.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 1001

        luxNVoadmDetectorFailureResolvedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a failure on the VOADM power 
                     monitor has been resolved.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 1002

        luxNVoadmOutofRangeTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the user configured settings
                     for a VOADM would force the power levels to be outside 
                     of allowed operating ranges for the current link 
                     conditions.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 1003

        luxNVoadmOutofRangeResolvedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when an existing VOADM out of range
                     condition is resolved.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 1004

        luxNsignalStrengthHighTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the receieve signal
                     strength is high.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 1005

        luxNsignalStrengthLowTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the receieve signal
                     strength is low.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 1006

        luxNsignalStrengthNormalTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the receieve signal
                     strength is normal.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 1007

        luxNlaserPowerOutOfRangeTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent upon detection of out of range
                     laser power.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 1008

        luxNlaserPowerNormalTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent upon detection of normal
                     laser power.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 1009

        luxNberHighThresholdExceeded  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent upon detecting that MCMESC's BER high threshold is
                     exceeds.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event. The port number 1 to 12 is applicable to CPE ports, a NULL
                     port number indicates the link.
                     Each event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 1010

        luxNberHighThresholdExceededNormal  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent upon detecting that MCMESC's BER high threshold is
                     not exceeded.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event. The port number 1 to 12 is applicable to CPE ports, a NULL
                     port number indicates the link.
                     Each event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 1011

        luxNberModerateThresholdExceeded  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent upon detecting that MCMESC's BER moderate threshold
                     is exceeded. The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event. The port number 1 to 12 is applicable to CPE ports, a NULL
                     port number indicates the link.
                     Each event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 1012

        luxNberModerateThresholdExceededNormal  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent upon detecting that MCMESC's BER moderate threshold
                     is not exceeded.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event. The port number 1 to 12 is applicable to CPE ports, a NULL
                     port number indicates the link.
                     Each event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 1013

        luxNSNMPKeepalive  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent out periodicly by the MPM when SNMP keep alive
                     functionality is enabled."
                ::= 2000

        luxNSNMPKeepalivesEnabled  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent upon SNMP keep alive functionality being enabled"
                ::= 2001

        luxNSNMPKeepalivesDisabled  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent upon SNMP keep alive functionality being disabled"
                ::= 2002

        luxNSNMPKeepaliveIntervalChanged  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the SNMP keep alive interval is modified"
                ::= 2003

        luxNTelnetClientEnabled  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "Telnet client has been enabled for active telnet sessions"
                ::= 2004

        luxNTelnetClientDisabled  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "Telnet client has been disabled for active telnet sessions"
                ::= 2005

        luxNsnmpAuthenticationFailureTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent upon receipt of invalid
                     community strings.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2017

        luxNcoldStartTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the device has reinitialized
                     itself.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2018

        luxNwarmStartTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the device has undergone
                     a warm boot.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2019

        luxNlossOfLightResolvedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a loss of light condition
                     has been resolved. For OCM/MCMT1/MCME1, it indicates that the link between two
                     optically connected channel cards is up.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2021

        luxNlossOfLightDetectedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a loss of light condition
                     has been detected. For OCM/MCMT1/MCME1, it indicates that the link between two
                     optically connected channel cards is down.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2022

        luxNntpEnableTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when NTP is enabled.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2023

        luxNntpDisableTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when NTP is disabled.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2024

        luxNntpTimeServerChangedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the NTP time
                     server is changed.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2025

        luxNntpUpdateIntervalChangedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the NTP update
                     interval is changed.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2026

        luxNtimeZoneChangedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the system time
                     zone is changed.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2027

        luxNspiConnectionUpTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "Obsolete.  This trap is sent when SPI communications
                     has been established with a card specified in the
                     source field.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2030

        luxNcardLostTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when SPI communications has been
                     lost with a card specified in the source field.
                     The reason is either that the card has been physically
                     removed or there exist a failure condition.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2031

        luxNConfigChangeTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a configuration change
                     has ocurred for a card specified in the source
                     field.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2034

        luxNstatsPollFailedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when statistics data can no longer
                     be gathered from a card in the specified source
                     field.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2035

        luxNCardFoundTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a card has been 
                     discovered in the chassis.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2040

        luxNlocalLoopbackEnabledTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the local loopback mode
                     has been enabled for a channel card in the
                     specified source field. The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2041

        luxNremoteLoopbackEnabledTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the remote loopback mode
                     has been enabled for a channel card in the
                     specified source field. The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2042

        luxNlocalLoopbackDisabledTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the local loopback mode
                     has been disabled for a channel card in the
                     specified source field. The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2043

        luxNremoteLoopbackDisabledTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the remote loopback mode
                     has been disabled for a channel card in the
                     specified source field. The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2044

        luxNftpSessionInitiatedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a ftp session has been
                     initiated from the CLI. The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2047

        luxNuserResetStatusTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "Obsolete.  This trap is sent when the status information
                     for a card specified in the source field has
                     been modified via the snmp agent.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2050

        luxNprotectionSwitchTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a protection switch has
                     occurred either automatically or manually.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2051

        luxNipAddressErrorTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "Obsolete.  This trap is sent when an error has
                     occurred while configuring the IP address.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2052

        luxNipNetmaskErrorTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "Obsolete.  This trap is sent when an error has
                     occurred while configuring the Netmask.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2053

        luxNdefaultGatewayErrorTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "Obsolete.  This trap is sent when an error has
                     occurred while configuring the default gateway.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2054

        luxNlossOfSignalTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a loss of signal is
                     detected on one of the ports on a channel card
                     specified in the source field.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2055

        luxNlossOfSignalNormalTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a loss of signal problem
                     on one of the ports on a channel card
                     specified in the source field has been corrected.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2056

        luxNlossOfFrameTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a loss of frame error
                     condition is detected on one of the ports on a
                     channel card specified in the source field.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2057

        luxNlossOfFrameNormalTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a loss of frame error
                     condition on one of the ports on a channel card
                     specified in the source field has been corrected.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2058

        luxNrecvAISTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a receive AIS (Alarm
                     Indication Signal) is detected on one of the ports
                     on a channel card specified in the source field.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2059

        luxNrecvAISNormalTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a receive AIS (Alarm
                     Indication Signal) problem on one of the ports
                     on a channel card specified in the source field
                     has been corrected.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2060

        luxNrecvYellowAlarmTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a receive receive yellow
                     alarm is detected on one of the ports on a channel
                     card specified in the source field.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2061

        luxNrecvYellowAlarmNormalTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a receive receive yellow
                     alarm problem on one of the ports on a channel
                     card specified in the source field has been
                     corrected.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2062

        luxNlineCodeViolationTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a line code violation error
                     condition is detected on one of the ports on a
                     channel card specified in the source field.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2063

        luxNlineCodeViolationNormalTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a line code violation error
                     condition on one of the ports on a channel card
                     specified in the source field has been corrected.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2064

        luxNframingAlarmTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a framing alarm is
                     detected on one of the ports on a channel card
                     specified in the source field.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2065

        luxNframingAlarmNormalTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a framing alarm problem
                     on one of the ports on a channel card specified
                     in the source field has been corrected.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2066

        luxNlossOfTimingTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a loss of timing condition
                     is detected on a channel card specified in
                     the source field.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2067

        luxNlossOfTimingNormalTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a loss of timing problem
                     on a channel card specified in the source field
                     has been corrected.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2068

        luxNselfTestFailTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a self-test failure
                     is detected on a channel card specified in
                     the source field.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2073

        luxNselfTestPassTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a successful self-test
                     is detected on a channel card specified in
                     the source field.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2074

        luxNIbmDownTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a problem is detected on a
                     inband management link.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2075

        luxNIbmNormalTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a problem is resolved on a
                     inband management link.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2076

        luxNnearendCardLoopbackEnabledTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that a near-end card
                     loopback has been enabled on an mcmt1/mcme1 or mcmesc card.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2077

        luxNnearendCardLoopbackDisabledTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                "This trap is sent to indicate that a near-end card
                 loopback has been disabled on an mcmt1/mcme1 or mcmesc card.
                 The source is a 4 or 5 tuple
                 specifying the type, location, shelf, slot ID, and
                 optionally the port number of the source of the
                 event.  In the case of the power supply and fan,
                 the shelf number is set to 0.  Each event has an
                 unique event ID.  It also has a preset event
                 severity.  The severity or trap type may be:
                 critical, major, minor, or normal.  For a given
                 event severity, there is a corresponding system
                 status, not necessarily the same as the event
                 severity.  For each reported trap, the IP address
                 of the CP responsible for sending this trap is
                 also included in the trap structure."
                ::= 2078

        luxNnetworkPortLoopbackEnabledTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                "This trap is sent to indicate that a network port
                 loopback has been enabled on an mcmt1/mcme1 or mcmesc card.
                 The source is a 4 or 5 tuple
                 specifying the type, location, shelf, slot ID, and
                 optionally the port number of the source of the
                 event.  In the case of the power supply and fan,
                 the shelf number is set to 0.  Each event has an
                 unique event ID.  It also has a preset event
                 severity.  The severity or trap type may be:
                 critical, major, minor, or normal.  For a given
                 event severity, there is a corresponding system
                 status, not necessarily the same as the event
                 severity.  For each reported trap, the IP address
                 of the CP responsible for sending this trap is
                 also included in the trap structure."
                ::= 2079

        luxNnetworkPortLoopbackDisabledTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that a network port
                     loopback has been disabled on an mcmt1/mcme1 or mcmesc card.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2080

        luxNnetworkCardLoopbackEnabledTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that a network card
                     loopback has been enabled on an mcmt1/mcme1 or mcmesc card.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2081

        luxNnetworkCardLoopbackDisabledTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that a network card
                     loopback has been disabled on an mcmt1/mcme1 or mcmesc card.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2082

        luxNnearendPortLoopbackEnabledTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that a nearend port
                     loopback has been enabled on an mcmt1/mcme1 or mcmesc card.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2083

        luxNnearendPortLoopbackDisabledTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that a nearend port
                     loopback has been disabled on an mcmt1/mcme1 or mcmesc card.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2084

        luxNpowerSupplyNotPresentTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the power supply
                     specified in the source field is not present.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2085

        luxNpowerSupplyOKTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the power supply
                     specified in the source field is performing
                     properly.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2086

        luxNpowerSupplyDegradedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the performance
                     of the power supply specified in the source field
                     has degraded.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2087

        luxNpowerSupplyFailureTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the power
                     supply specified in the source field has failed.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2088

        luxNfanOKTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the fan
                     specified in the source field is performing
                     properly.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2089

        luxNfanFailureTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the fan
                     specified in the source field has failed.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2090

        luxNcsimDataUnavailableTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the ColorSIM
                     module as specified in the source field is in
                     a Data Unavailable state.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2091

        luxNcsimDataAvailableTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the ColorSIM
                     module as specified in the source field is in
                     a Data Available state.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2092

        luxNcsimModuleFailureTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the ColorSIM
                     module as specified in the source field has
                     failed to operate properly.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2093

        luxNethernetLossOfCarrierTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that loss of carrier
                     has been detected on the CPE's ethernet port.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2094

        luxNethernetCarrierDetectedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the carrier
                     has been detected on the CPE's ethernet port.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2095

        luxNtimingPriorityChangedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the timing
                     priority for a card has been changed.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2096

        luxNopenFiberCPEAlarmTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when an open fiber condition
                     on the CPE has been detected from a
                     card specified in the source field.  The
                     source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2097

        luxNopenFiberCPEAlarmResolvedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when an open fiber condition
                     on the CPE has been resolved from a
                     card specified in the source field.  The
                     source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2098

        luxNstandbyMPMDetectedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the standby MPM card
                     has been detected.  The
                     source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2099

        luxNstandbyMPMLostTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the standby MPM card
                     has been lost.  The
                     source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2100

        luxNprotectionLinkFailureTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the protection link has
                     become unaviable due to either low receive power
                     level or an open fiber condition.  The
                     source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2101

        luxNprotectionLinkFailureResolvedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the protection link
                     has become available as a result of a corrective
                     action to resolve a previous failure condition.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2102

        luxNtopologyDatabaseChangedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent whenever a link has either been
                     added or deleted from the topology database.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2103

        luxNredundantDatabaseCopyComplete  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent upon completion of a forced redundant database 
                     copy.  The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2104

        luxNredundantDatabaseCopyFailed  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a failure occurs during a 
                     forced redundant database copy.  The source is a 
                     4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2105

        luxNimageExportInProgressTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when an module image is being
                     exported from the MPM through ftp. 
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2106

        luxNimageExportSuccessTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a module image exported from
                     the MPM through ftp has been completed successfully.   
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2107

        luxNimageExportFailedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a module image exported
                     from the MPM through ftp has failed.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2108

        luxNunknownCardTypeDetectedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a module with an unknown
                     card type is detected.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2109

        luxNosamBiasCurrentOverLimitTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the osam's bias current
                     exceeds 90% of allowed maximum.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2110

        luxNosamBiasCurrentNormal  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the osam's bias current
                     is within normal range.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2111

        luxNosamTecCurrentOverLimit  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the osam's TEC current
                     is above the specified limit.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2112

        luxNosamTecCurrentNormal  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the osam's TEC current
                     is within normal range.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2113

        luxNosamLaserTemperatureDrift  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the osam's laser temperature
                     drifts by more than +/- 2 degree Celsius.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2114

        luxNosamLaserTemperatureStable  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the osam's laser temperature
                     no longer drifts.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2115

        luxNosamMaxInputPowerReached  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the osam's input power
                     is greater than or equal to 9 dBm.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2116

        luxNosamInputPowerBackDownNormal  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the osam's input power
                     has fallen within normal range.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2117

        luxNosamMaxOutputPowerReached  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the osam's output power
                     is greater than or equal to 13 dBm.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2118

        luxNosamOutputPowerNormal  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the osam's output power
                     is within normal range.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2119

        luxNosamOpticalGainDeltaExceeded  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the osam's gain delta
                     is greater than or equal to 4 dB.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2120

        luxNosamOpticalGainDeltaNormal  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the osam's gain delta
                     is less than 4 dB.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2121

        luxNosamMinInputPowerBelowLimit  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the osam's input power is
                     less than or equal to -30 dBm.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2122

        luxNosamInputPowerBackUpNormal  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the osam's input power
                     has risen within normal range.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2123

        luxNosamSingleAprSensorFailed  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the osam's APR sensor is
                     not functioning.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2124

        luxNosamSingleAprSensorNormal  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the osam's APR sensor has
                     become functional.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2125

        luxNosamDualAprSensorFailed  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when both of the osam's APR sensors 
                     are not functioning.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2126

        luxNosamDualAprSensorNormal  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when both of the osam's APR sensors 
                     has become functional.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2127

        luxNosamFiberDisconnected  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a fiber disconnect condition
                     has been detected on an osam module.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2128

        luxNosamFiberConnected  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a fiber connect condition
                     has been detected after a fiber disconnect on an osam 
                     module. The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2129

        luxNosamControlChanged  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when either the current control or
                     gain control has been changed.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2130

        luxNosamLaserModuleOn  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the laser module has
                     been turned on by the osam firmware.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2131

        luxNosamLaserModuleOff  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the laser module has
                     been turned off by the osam firmware.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2132

        luxNipAuthenticationFailure  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "Not yet supported.  This trap is sent when access
                     from an invalid IP address based on the ACL has
                     been detected.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2133

        luxNftpCompletedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the ftp session has
                     been disconnected.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2134

        luxNftpHostFailedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the MPM is unable to
                     connect to the ftp host. 
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2135

        luxNimageUpdateInProgressTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when an module image is being
                     downloaded to MPM through ftp. 
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2136

        luxNimageUpdateSuccessTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a module image download to
                     MPM through ftp has been completed successfully.   
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2137

        luxNimageUpdateFailedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a module image download
                     to MPM through ftp has failed.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2138

        luxNmoduleUpdateInProgressTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a module image is being
                     transferred from the MPM to the module.  
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2139
        
        luxNmoduleUpdateSuccessTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a module image transfer
                     from the MPM to the module has been completed
                     successfully.  
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2140

        luxNmoduleUpdateFailedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a module image transfer
                     from the MPM to the module has failed.  
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2141

        luxNethernetLinkFailure  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent upon detection of the ethernet
                     link failure on the MPM.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2142

        luxNethernetLinkFailureResolved  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent upon resolution of the ethernet
                     link failure on the MPM.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2143

        luxNfanNotPresentTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the fan
                     specified in the source field is not present
                     in the system. The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2144

        luxNcardMismatchTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a card mismatch is found in a given slot.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2145

        luxNpwrFeedLowVoltageTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the DC voltage level on the power feed
                     reaches very close to the shutdown voltage.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2146

        luxNpwrFeedLowVoltageRecoveryTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the DC voltage level on the power feed
                     recovers from the low voltage level condition .
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2147

        luxNpwrFeedOKTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the DC voltage level on the power feed
                     is within the operating window of the chassis .
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2148

        luxNpwrFeedFailureTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the DC voltage level on the power feed
                     is either too low or too high to operate the chassis
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2149

        luxNpwrFeedBrkOpenTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a user manually flips open the breaker relay
                     switch attached to that feed.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2150

        luxNextCritAlmInpTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when an alarm gets generated at an external
                     alarm input that is configured for critical severity.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply, fan and ext. alarm input,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2151

        luxNextMajAlmInpTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when an alarm gets generated at an external
                     alarm input that is configured for majority severity.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply, fan and ext. alarm input,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2152

        luxNextMinorAlmInpTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when an alarm gets generated at an external
                     alarm input that is configured for minor severity.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply, fan and ext. alarm input,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2153

        luxNextClearAlmInpTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when an alarm gets cleared at an external
                     alarm input.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply, fan and ext. alarm input,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2154

        luxNpwrFeedOverVoltageTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the DC voltage level on the power feed
                     reaches very close to the shutdown voltage on the higher side.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2155

        luxNpwrFeedOverVoltageRecoveryTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the DC voltage level on the power feed
                     recovers from the over voltage level condition .
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2156

        luxNstandbySWMismatchTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when there is a mismatch between the software version of 
                     standby and active MPM.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2157

        luxNstandbyDBNotSupportedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the standby MPM do not 
                     support Active MPM's database.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2158

        luxNactiveStandbySWAlignedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the software version between 
                     standby and active MPM is aligned.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2159

        luxNactiveStandbyDBAlignedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the database version between 
                     standby and active MPM is aligned.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2160

        luxNmcmescTestSequenceOnTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the test-sequence is set to ON
                     on an MCMESC card specified in the source field.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event. The port number 1 to 12 is applicable to CPE ports, a NULL
                     port number indicates the link.
                     Each event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2161

        luxNmcmescTestSequenceOffTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the test-sequence is set to OFF
                     on an MCMESC card specified in the source field.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event. The port number 1 to 12 is applicable to CPE ports, a NULL
                     port number indicates the link.
                     Each event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2162

        luxNselfTestStartedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when self-test 
                     has started for a channel card in the
                     specified source field. The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2163

        luxNselfTestEndedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when self-test 
                     has ended for a channel card in the
                     specified source field. The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2164

        luxNvoadmMuxSetPointOutOfRange  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a VOADM module has detected that the
                     recently configured mux set point value would bring down the fibre
                     if applied.  The set point value is rejected and the MPM and 
                     module returns to the previously configured mux set point. 
                     The source is a 4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and optionally the port number of the source
                     of the event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2165

        luxNvoadmDemuxForceConfig  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a VOADM module forces its Demux configuration
                     into fixed power mode. Forcing the Demux mode to fixed power mode
                     can only occur when the Demux ports are configured for fixed
                     attentuation mode and network conditions change sufficently
                     that the current configuration may cause damage to the laser.             
                     The source is a 4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and optionally the port number of the source
                     of the event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2166

        luxNSfpNotPresent  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a missing SFP is detect.
                     The source is a 4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and optionally the port number of the source
                     of the event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2167

        luxNSfpPresent  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a SFP has been inserted into the
                     module .The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number
                     of the source of the event.  In the case of the power 
                     supply and fan, the shelf number is set to 0.  Each event
                     has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2168

        luxNSfpFailure  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a SFP failure is detected.             
                     The source is a 4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and optionally the port number of the source
                     of the event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2169

        luxNSfpFailureResolved  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a SFP failure is resolved.             
                     The source is a 4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and optionally the port number of the source
                     of the event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2170

        luxNSfpNotAuthorized  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when an unauthorized SFP is detected.             
                     The source is a 4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and optionally the port number of the source
                     of the event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2171

        luxNSfpAuthorized  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when an unauthorized SFP is replaced with
                     an authorized SFP. The source is a 4 or 5 tuple specifying
                     the type, location, shelf, slot ID, and optionally the port
                     number of the source of the event.  In the case of the
                     power supply and fan, the shelf number is set to 0. Each
                     event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2172

        luxNSfpRateMismatch  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a SFP does not supported the user
                     configured line rate. The source is a 4 or 5 tuple specifying
                     the type, location, shelf, slot ID, and optionally the port
                     number of the source of the event.  In the case of the power
                     supply and fan, the shelf number is set to 0.  Each event has
                     an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2173

        luxNSfpRateMismatchResolved  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a SFP that does not support the user
                     configured line rate is replaced with an SFP that does.
                     The source is a 4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and optionally the port number of the source
                     of the event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2174

        luxNLinkRxSignalDegraded  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the packet error rate increases over
                     10e-4.  The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number
                     of the source of the event.  In the case of the power
                     supply and fan, the shelf number is set to 0.  Each event
                     has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2175

        luxNLinkRxSignalDegradedResolved  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the packet error rate falls below
                     10e-4. The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number
                     of the source of the event.  In the case of the power
                     supply and fan, the shelf number is set to 0.  Each event
                     has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2176

        luxNLinkTxFault  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a Tx fault is detect on the link port.
                     The source is a 4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and optionally the port number of the source
                     of the event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2177

        luxNLinkTxFaultResolved  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a Tx fault is resolved on the link port.
                     The source is a 4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and optionally the port number of the source
                     of the event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2178

        luxNPortTxFault  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a Tx fault is detect on a CPE port.
                     The source is a 4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and optionally the port number of the source
                     of the event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2179

        luxNPortTxFaultResolved  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a Tx fault is resolved on a CPE port.
                     The source is a 4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and optionally the port number of the source
                     of the event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2180

        luxNXfpNotPresent  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a missing XFP is detect.
                     The source is a 4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and optionally the port number of the source
                     of the event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2181

        luxNXfpPresent  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a XFP has been inserted into the
                     module .The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number
                     of the source of the event.  In the case of the power 
                     supply and fan, the shelf number is set to 0.  Each event
                     has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2182

        luxNXfpFailure  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a XFP failure is detected.             
                     The source is a 4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and optionally the port number of the source
                     of the event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2183

        luxNXfpFailureResolved  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a XFP failure is resolved.             
                     The source is a 4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and optionally the port number of the source
                     of the event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2184

        luxNXfpNotAuthorized  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when an unauthorized XFP is detected.             
                     The source is a 4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and optionally the port number of the source
                     of the event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2185

        luxNXfpAuthorized  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when an unauthorized XFP is replaced with
                     an authorized XFP. The source is a 4 or 5 tuple specifying
                     the type, location, shelf, slot ID, and optionally the port
                     number of the source of the event.  In the case of the
                     power supply and fan, the shelf number is set to 0. Each
                     event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2186

        luxNXfpRateMismatch  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a XFP does not supported the user
                     configured line rate. The source is a 4 or 5 tuple specifying
                     the type, location, shelf, slot ID, and optionally the port
                     number of the source of the event.  In the case of the power
                     supply and fan, the shelf number is set to 0.  Each event has
                     an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2187

        luxNXfpRateMismatchResolved  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a XFP that does not support the user
                     configured line rate is replaced with a XFP that does.
                     The source is a 4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and optionally the port number of the source
                     of the event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2188

        luxNCpeXfpNotPresent  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a missing XFP is detect for a CPE port.
                     The source is a 4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and optionally the port number of the source
                     of the event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2189

        luxNCpeXfpPresent  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a XFP has been inserted into the
                     module CPE port.The source is a 4 or 5 tuple specifying
                     the type, location, shelf, slot ID, and optionally the 
                     port number of the source of the event.  In the case of
                     the power  supply and fan, the shelf number is set to 0.
                     Each event has an unique event ID.  It also has a preset
                     event severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2190

        luxNCpeXfpFailure  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a CPE XFP failure is detected.             
                     The source is a 4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and optionally the port number of the source
                     of the event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2191

        luxNCpeXfpFailureResolved  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a CPE XFP failure is resolved.             
                     The source is a 4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and optionally the port number of the source
                     of the event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2192

        luxNCpeXfpNotAuthorized  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when an unauthorized XFP is detected in a
                     CPE prot. The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number of
                     the source of the event.  In the case of the power supply 
                     and fan, the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2193

        luxNCpeXfpAuthorized  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when an unauthorized XFP is replaced with
                     an authorized XFP in a CPE port. The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and optionally
                     the port number of the source of the event.  In the case of the
                     power supply and fan, the shelf number is set to 0. Each
                     event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2194

        luxNCpeXfpRateMismatch  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a CPE XFP does not supported the user
                     configured line rate. The source is a 4 or 5 tuple specifying
                     the type, location, shelf, slot ID, and optionally the port
                     number of the source of the event.  In the case of the power
                     supply and fan, the shelf number is set to 0.  Each event has
                     an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2195

        luxNCpeXfpRateMismatchResolved  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a CPE XFP that does not support the
                     user configured line rate is replaced with an XFP that does.
                     The source is a 4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and optionally the port number of the source
                     of the event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2196

        luxNOutOfFrame  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when an out of frame error is detected.
                     The source is a 4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and optionally the port number of the source
                     of the event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2197

        luxNOutOfFrameResolved  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when an out of frame error is resolved.
                     The source is a 4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and optionally the port number of the source
                     of the event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2198

        luxNCpeLossOfFrame  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a loss of frame error is detected on
                     a CPE port. The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number of
                     the source of the event.  In the case of the power supply
                     and fan, the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2199

        luxNCpeLossOfFrameResolved  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a loss of frame error is resolved on
                     a CPE port. The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number of
                     the source of the event.  In the case of the power supply
                     and fan, the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2200

        luxNCpeOutOfFrame  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when an out of frame error is detected on
                     a CPE port. The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number of
                     the source of the event.  In the case of the power supply
                     and fan, the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2201

        luxNCpeOutOfFrameResolved  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when an out of frame error is resolved on
                     a CPE port. The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number of
                     the source of the event.  In the case of the power supply
                     and fan, the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2202

        luxNCdrFailure  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a CDR failure is detected.
                     The source is a 4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and optionally the port number of the source
                     of the event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2203

        luxNCdrFailureResolved  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a CDR failure is resolved.
                     The source is a 4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and optionally the port number of the source
                     of the event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2204

        luxNBitError10Em3  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the modules bit error rate exceeds
                     10E-3. The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number
                     of the source of the event.  In the case of the power
                     supply and fan, the shelf number is set to 0.  Each
                     event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2205

        luxNBitError10Em3Resolved  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the modules bit error rate falls below
                     10E-3. The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number
                     of the source of the event.  In the case of the power
                     supply and fan, the shelf number is set to 0.  Each
                     event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2206

        luxNBitError10Em4  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the modules bit error rate exceeds
                     10E-4. The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number
                     of the source of the event.  In the case of the power
                     supply and fan, the shelf number is set to 0.  Each
                     event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2207

        luxNBitError10Em4Resolved  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the modules bit error rate falls below
                     10E-4. The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number
                     of the source of the event.  In the case of the power
                     supply and fan, the shelf number is set to 0.  Each
                     event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2208

        luxNBitError10Em6  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the modules bit error rate exceeds
                     10E-6. The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number
                     of the source of the event.  In the case of the power
                     supply and fan, the shelf number is set to 0.  Each
                     event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2209

        luxNBitError10Em6Resolved  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the modules bit error rate falls below
                     10E-6. The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number
                     of the source of the event.  In the case of the power
                     supply and fan, the shelf number is set to 0.  Each
                     event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2210

        luxNBitError10Em7  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the modules bit error rate exceeds
                     10E-7. The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number
                     of the source of the event.  In the case of the power
                     supply and fan, the shelf number is set to 0.  Each
                     event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2211

        luxNBitError10Em7Resolved  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the modules bit error rate falls below
                     10E-7. The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number
                     of the source of the event.  In the case of the power
                     supply and fan, the shelf number is set to 0.  Each
                     event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2212

        luxNAisReceived  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when AIS-L is received on the port.
                     The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number
                     of the source of the event.  In the case of the power
                     supply and fan, the shelf number is set to 0.  Each
                     event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2213

        luxNAisReceivedResolved  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when AIS-L is no longer received on the
                     port. The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number
                     of the source of the event.  In the case of the power
                     supply and fan, the shelf number is set to 0.  Each
                     event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2214

        luxNAisTransmitted  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when starts transmitting on the port.
                     The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number
                     of the source of the event.  In the case of the power
                     supply and fan, the shelf number is set to 0.  Each
                     event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2215

        luxNAisTransmittedResolved  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when is no longer transmitting on the
                     port. The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number
                     of the source of the event.  In the case of the power
                     supply and fan, the shelf number is set to 0.  Each
                     event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2216

        luxNcaseTemperatureHiTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when case temperature is HI. 
                     The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number
                     of the source of the event.  In the case of the power
                     supply and fan, the shelf number is set to 0.  Each
                     event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2225

        luxNcaseTemperatureNormalTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when case temperature is normal. 
                     The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number
                     of the source of the event.  In the case of the power
                     supply and fan, the shelf number is set to 0.  Each
                     event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2226

        luxNcaseTemperatureLoTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when case temperature is LO. 
                     The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number
                     of the source of the event.  In the case of the power
                     supply and fan, the shelf number is set to 0.  Each
                     event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2227

        luxNcaseTemperatureLoNormalTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when case temperature is normal. 
                     The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number
                     of the source of the event.  In the case of the power
                     supply and fan, the shelf number is set to 0.  Each
                     event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2228

        luxNpumpTemperatureHiTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when pump temperature is HI. 
                     The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number
                     of the source of the event.  In the case of the power
                     supply and fan, the shelf number is set to 0.  Each
                     event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2229

        luxNpumpTemperatureNormalTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when pump temperature is normal. 
                     The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number
                     of the source of the event.  In the case of the power
                     supply and fan, the shelf number is set to 0.  Each
                     event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2230

        luxNcoilTemperatureHiTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when coil temperature is HI. 
                     The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number
                     of the source of the event.  In the case of the power
                     supply and fan, the shelf number is set to 0.  Each
                     event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2231

        luxNcoilTemperatureNormalTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when coil temperature is normal. 
                     The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number
                     of the source of the event.  In the case of the power
                     supply and fan, the shelf number is set to 0.  Each
                     event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2232

        luxNlossOutputPowerTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when loss of output power (or gain) is detected. 
                     The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number
                     of the source of the event.  In the case of the power
                     supply and fan, the shelf number is set to 0.  Each
                     event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2233

        luxNlossOutputPowerNormalTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when loss of output power (or gain) is normal. 
                     The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number
                     of the source of the event.  In the case of the power
                     supply and fan, the shelf number is set to 0.  Each
                     event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2234

        luxNreflectedOutputPowerHiTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when excessive reflected output power is detected. 
                     The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number
                     of the source of the event.  In the case of the power
                     supply and fan, the shelf number is set to 0.  Each
                     event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2235

        luxNreflectedOutputPowerNormalTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when reflected output power is normal. 
                     The source is a 4 or 5 tuple specifying the type,
                     location, shelf, slot ID, and optionally the port number
                     of the source of the event.  In the case of the power
                     supply and fan, the shelf number is set to 0.  Each
                     event has an unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 2236

        luxNlineRateNotSuppoted  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the module hardware 
                     does not support the configured line rate.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3001

        luxNmpmBootImageChangedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the executable
                     image for the MPM has been changed. Upon reset of
                     the MPM card, this new bootfile will be used.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3002

        luxNdateTimeSetTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the date and
                     time of the system has been changed.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3003

        luxNuserAddedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that a new user
                     has been added to the system.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3004

        luxNuserDeletedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that a user
                     has been deleted from the system.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3005

        luxNuserPasswordChangeTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the password
                     of one of the user's has been changed.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3006

        luxNuserLevelModifiedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the privilege
                     level of one of the user's has been changed.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3007

        luxNsystemNameChangeTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the name of
                     the system has been changed.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3008

        luxNcardAddedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that a new card has
                     been added to the system through either CLI/SNMP
                     in the specified source field.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3009

        luxNcardDeletedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that a card has
                     been deleted from the system through either
                     CLI/SNMP in the specified source field.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3010

        luxNmpmRedundancySwitchOverTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that a mpm
                     switchover has occurred.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3011

        luxNconnectionAddedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that a connectino
                     has been added to an ofcm/ofcd card.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3012

        luxNconnectionDeletedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that a connection
                     has been deleted from an ofcm/ofcd card.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3013

        luxNipAddressChangedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the IP address
                     has been changed successfully.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3014

        luxNipNetmaskChangedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the netmask
                     has been changed successfully.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3015

        luxNdefaultGatewayChangedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the default
                     gateway has been changed successfully.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3016

        luxNGetCommunityChangeTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the getcommunity
                     has been changed.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3017

        luxNSetCommunityChangeTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the setcommunity
                     has been changed.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3018

        luxNModuleResetTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that a module has
                     been reset.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3019

        luxNtopologyRediscoveredTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the topology
                     database has been rediscovered which is triggered
                     through either CLI or snmp. The source is a
                     4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3020

        luxNcolorsimEnabledTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the ColorSIM
                     feature has been enabled. The source is a
                     4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3021

        luxNcolorsimDisabledTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the ColorSIM
                     feature has been disabled. The source is a
                     4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3022

        luxNautoCutoffEnabledTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the auto cutoff
                     feature has been enabled. The source is a
                     4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3023

        luxNautoCutoffDisabledTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the auto cutoff
                     feature has been disabled. The source is a
                     4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3024

        luxNextAlarmsEnabledTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the external
                     alarm closures have been enabled. The source is a
                     4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3025

        luxNextAlarmsDisabledTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the external
                     alarm closures have been disabled. The source is a
                     4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3026

        luxNdlModuleActivatedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that a module
                     activation, switching to another module image
                     version, has occurred.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3027

        luxNhttpEnabledTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the http
                     server has been enabled. The source is a
                     4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3032

        luxNhttpDisabledTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the http
                     server has been disabled. The source is a
                     4 or 5 tuple specifying the type, location,
                     shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3033

        luxNstaticRouteAddedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that a new route has
                     been added to the system through either CLI/SNMP
                     in the specified source field.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure. The eveDescr  field consists of
                     trap description and the route information - local CC shelf, slot 
                     and destination IP address"
                ::= 3034

        luxNstaticRouteDeletedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that a route has
                     been deleted from the system through either CLI/SNMP
                     in the specified source field.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event. Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure. The eveDescr  field consists of
                     trap description and the route information - local CC shelf, slot 
                     and destination IP address"
                ::= 3035


        luxNupsrProtectionSwitchOverSrc  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that UPSR protection switch over occurred 
                     on the source either through SNMP or CLI. If the module type is OCM
                     for this trap, then after issuing this trap it goes into standby mode.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event. Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3036

        luxNupsrProtectionSwitchOverDest  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that UPSR protection switch over occurred 
                     on the destination either through SNMP or CLI. If the module type is OCM
                     for this trap, then after issuing this trap it goes into active mode
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event. Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3037

        luxNimnIpAddressChanged  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that a IMN Ip address is successfully
                     changed either through SNMP or CLI.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event. Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3038


        luxNupsrNormal  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that UPSR is successfully
                     enabled either through SNMP or CLI on the system.
                     This is done once UPSR functionality is normal on the 
                     system.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event. Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3039

        luxNupsrDegraded  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that UPSR is successfully
                     disabled either through SNMP, CLI or SPI driver on the system.
                     This is done after the UPSR functionality on the system is degraded
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event. Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3040

        luxNusrOneAlarmAction  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that user has performed acknowledgment/
                     unacknowledgment/Clearing of a single alarm in the alarm log either 
                     through SNMP or CLI .
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event. Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3041

        luxNusrAllAlarmAction  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that user has performed acknowledgment/
                     unacknowledgment/Clearing of all alarms in the alarm log either through 
                     SNMP or CLI .
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event. Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3042

        luxNringConfigurationChanged  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the user has changed the 
                     ring configuration either through deletion or addition of
                     ringId or pathId.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event. Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure. The eveDescr  field consists of
                     trap description and the cross connect information "
                ::= 3047

        luxNeventLogCleared  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that the user has cleared the
                     event log either through CLI or SNMP.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event. Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3048

        luxNextAlarmInpTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when an user sets up alarm severity 
                     (crit/maj/minor/disable) on external alarm input.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply, fan and ext. alarm input,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3049

        luxNextAudioAlarmTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when an user enables or disables audio alarm.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply, fan and ext. alarm input,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3050

        luxNTrapHostConfigChangeTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a trap host is added, deleted, or
                     modified (port configuration).
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3051

        luxNTrapHostImnRouteEnabled  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    ""
                ::= 3052

        luxNTrapHostImnRouteDisabled  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    ""
                ::= 3053

        luxNTrapHostAutoUpdateEnabled  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    ""
                ::= 3054

        luxNTrapHostAutoUpdateDisabled  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    ""
                ::= 3055

        luxNTrapPathAdded  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a path is configured.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply, fan and ext. alarm input,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3056

        luxNTrapPathDeleted  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a path is deleted.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply, fan and ext. alarm input,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3057

        luxNdlModuleActivateFailedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a module activation, 
                     switching to another module image version, 
                     has failed.
                     The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3058

        luxNLogServerAddedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a syslog server has been
                     added. The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3059

        luxNLogServerDeletedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a syslog server has been
                     deleted. The source is a 4 or 5 tuple specifying the
                     type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3060

        luxNLogMaskChangedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the syslog mask has been
                     changed. The source is a 4 or 5 tuple specifying
                     the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3061

        luxNRadiusAuthChangedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the radius authentication order
                     has been changed. The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3062

        luxNRadiusDefaultRealmChangedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the radius default realm
                     has been changed. The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3063

        luxNRadiusNasIdChangedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the radius NAS Identifier
                     has been changed. The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3064

        luxNRadiusRetriesChangedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the radius retries has been
                     changed. The source is a 4 or 5 tuple specifying
                     the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3065

        luxNRadiusServerAddedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when a radius server has been
                     added. The source is a 4 or 5 tuple specifying
                     the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3066

        luxNRadiusServerDeletedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when radius server has been
                     deleted. The source is a 4 or 5 tuple specifying
                     the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3067

        luxNRadiusServerModifiedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when radius server port or secret
                     has been modified. The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3068

        luxNRadiusTimeoutChangedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the radius timeout has been
                     changed. The source is a 4 or 5 tuple specifying
                     the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3069

        luxNSshEnabledTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the SSHD has been enabled.
                     The source is a 4 or 5 tuple specifying the type
                     location, shelf, slot ID, and optionally the port
                     number of the source of the event.  In the case 
                     of the power supply and fan, the shelf number is 
                     set to 0.  Each event has an unique event ID. It 
                     also has a preset event severity.  The severity 
                     or trap type may be: critical, major, minor, or 
                     normal.  For a given event severity, there is a 
                     corresponding system status, not necessarily the
                     same as the event severity.  For each reported 
                     trap, the IP address of the CP responsible for 
                     sending this trap is also included in the trap 
                     structure."
                ::= 3070

        luxNSshDisabledTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the SSHD has been disabled.
                     The source is a 4 or 5 tuple specifying the type
                     location, shelf, slot ID, and optionally the port
                     number of the source of the event.  In the case 
                     of the power supply and fan, the shelf number is 
                     set to 0.  Each event has an unique event ID. It 
                     also has a preset event severity.  The severity 
                     or trap type may be: critical, major, minor, or 
                     normal.  For a given event severity, there is a 
                     corresponding system status, not necessarily the
                     same as the event severity.  For each reported 
                     trap, the IP address of the CP responsible for 
                     sending this trap is also included in the trap 
                     structure."
                ::= 3071

        luxNSshKeySizeSetTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the SSHD key size has been
                     changed. The source is a 4 or 5 tuple specifying
                     the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3072

        luxNSshMaxSessionsSetTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the telnet/SSHD max sessions
                     has been changed. The source is a 4 or 5 tuple 
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3073

        luxNSshKeyGeneratedTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent when the SSH DSS key has finished
                     being generated. The source is a 4 or 5 tuple 
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 3074

        luxNlogonIntruderTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that someone is
                     repeatly trying to logon using an invalid
                     password.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 4000

        luxNlogonSessionStarted  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that a user has
                     logged into the MPM.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 4001

        luxNlogonSessionClosed  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that a user has
                     logged out of the MPM.  The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 4002

        luxNcpAuthenticationErrorTrap  TRAP-TYPE
                ENTERPRISE  luxN
                VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
                            eveSysStatus, eveSource,  cpIpAddress, eveSeqNum }
                DESCRIPTION
                    "This trap is sent to indicate that an invalid
                     login attempt has been detected.
                     The source is a 4 or 5 tuple
                     specifying the type, location, shelf, slot ID, and
                     optionally the port number of the source of the
                     event.  In the case of the power supply and fan,
                     the shelf number is set to 0.  Each event has an
                     unique event ID.  It also has a preset event
                     severity.  The severity or trap type may be:
                     critical, major, minor, or normal.  For a given
                     event severity, there is a corresponding system
                     status, not necessarily the same as the event
                     severity.  For each reported trap, the IP address
                     of the CP responsible for sending this trap is
                     also included in the trap structure."
                ::= 4003

END