WebGraph-Thermometer-US-MIB DEFINITIONS ::= BEGIN
----------------------------------------------------------------
-- Revison: 1.26
----------------------------------------------------------------
-- 28.06.2006 	New: Community String Trap
--		
----------------------------------------------------------------
-- Revison: 1.25
----------------------------------------------------------------
-- 22.05.2006 	Table entry names changed
--		
----------------------------------------------------------------
-- Revison: 1.24
----------------------------------------------------------------
-- 26.07.2005 	#57605, WebGraph Thermometer
--		CRON timer function
----------------------------------------------------------------
-- Revison: 1.23
----------------------------------------------------------------
-- 14.07.2005 	#57605, WebGraph Thermometer
--		FTP functions
----------------------------------------------------------------
-- Revison: 1.22
----------------------------------------------------------------
-- 02.06.2005 	#57605, WebGraph Thermometer
--		Trap NMS annotations
----------------------------------------------------------------
-- Revison: 1.21
----------------------------------------------------------------
-- 19.04.2005 	#57605, WebGraph Themometer
--		Mail Authentication
----------------------------------------------------------------
-- Revison: 1.20
----------------------------------------------------------------
-- 05.11.2004 	#57605, WebGraph
--		New: Syslog
--		     
----------------------------------------------------------------
-- Revison: 1.19
----------------------------------------------------------------
-- 27.09.2004 	#57601/3/4, Webio Digital
--		New: 
--		     Entry AlarmHysteresis corrected
----------------------------------------------------------------
-- Revison: 1.18
----------------------------------------------------------------
-- 21.07.2004 	#57601/3/4, Webio Anx
--		New: 
--		     Diagnosis
----------------------------------------------------------------
-- Revison: 1.17
----------------------------------------------------------------
-- 28.06.2004 	#57630/1/2, Webio Digital
--		Neu: Puls Mode
----------------------------------------------------------------
-- Revison: 1.16
----------------------------------------------------------------
-- 16.04.2004 	New: #57632, Webio Digital EA24x24
--
--		#57630/1, Webio Digital EA12x12
--		New:
--			wtWebioAn1GraphInputCounterClear
----------------------------------------------------------------
-- Revison: 1.15
----------------------------------------------------------------
-- 27.02.2004 	#57630/1, Webio Digital EA12x12
--		New:
--		Length changed to 32 Bit:
--			wtWebioEA12x12InputValue
--			wtWebioEA12x12OutputValue
--			wtWebioEA12x12LoadControlView
--			wtWebioEA12x12LCShutDownView
--			wtWebioEA12x12SetOutput
--			wtWebioEA12x12AlarmInputTrigger
--			wtWebioEA12x12AlarmOutputTrigger
--			wtWebioEA12x12PortOutputSafetyState
----------------------------------------------------------------
-- Revison: 1.14
----------------------------------------------------------------
-- 16.02.2004 	#57630/1, Webio Digital EA12x12
--		New:
--		Text: Location, Contact
--		SNMP: ColdStart, WarmStart, ComunityString Read/RW
--		Alarm: ColdStart / WarmStart trigger
--
-- 	 	#57601, 1xWebThermometer
--		#57603, 2xWebThermometer		
--		#57604, 8xWebThermometer
--		New:
--		Alarm Hysteresis 
--		Alarm Clear Traps and Mails
----------------------------------------------------------------
-- Revison: 1.13
----------------------------------------------------------------
-- 05.02.2004 	#57601, 1xWebThermometer
--		#57603, 2xWebThermometer		
--		#57604, 8xWebThermometer
--		New:
--		Text: Location, Contact
--		SNMP: ColdStart, WarmStart, ComunityString Read/RW
--		Alarm: ColdStart / WarmStart trigger
----------------------------------------------------------------
-- Revison: 1.12
----------------------------------------------------------------
-- 05.11.2003 	#57601, 1xWebThermometer
--		#57603, 2xWebThermometer		
--		#57604, 8xWebThermometer
--		New features:
--		Mail  : Option CSV attachment
--		Port  : Offset calibration
--		Alarm : TCP Client mode		
----------------------------------------------------------------
-- Revison: 1.11
----------------------------------------------------------------
-- 28.10.2003 	#57630/1, Webio Digital EA12x12
--		New features:
--		Alarm : TCP Client mode		
--		Inputs: Puls filter
----------------------------------------------------------------
-- Revison: 1.10
----------------------------------------------------------------
-- 22.07.2003 	#57630, Webio Digital EA12x12
--		New navigation tree, new binary modes		
--
----------------------------------------------------------------
-- Revison: 1.09
----------------------------------------------------------------
-- 24.03.2003 	Trap Enterprise (Type 1, 2) corrected 
----------------------------------------------------------------
-- Revison: 1.08
----------------------------------------------------------------
-- 04.03.2003 	reconciled the language versions DE/US
----------------------------------------------------------------
-- Revison: 1.07
----------------------------------------------------------------
-- 25.02.2003 	Correction: wtWebioEA12x12LoadControl
----------------------------------------------------------------
-- Revison: 1.06
----------------------------------------------------------------
-- 24.02.2003 	New:
--		#57630, Webio EA12x12, LoadControl Group
--		Correction: Trap variable names
----------------------------------------------------------------
-- Revison: 1.05
----------------------------------------------------------------
-- 21.01.2003 	New:
--		#57630, Webio EA12x12
----------------------------------------------------------------
-- Revison: 1.04
----------------------------------------------------------------
-- 02.01.2003 	New:
--		#57601, 1xWebThermometer
--		#57603, 2xWebThermometer, 8 alarms
----------------------------------------------------------------
-- Revison: 1.03
----------------------------------------------------------------
-- 21.11.2002 	New:
--		#57604, 2xWebThermometer, BOOTP, StartupSite
--		#57603, 8xWebThermometer, BOOTP, StartupSite
----------------------------------------------------------------
-- Revison: 1.02
----------------------------------------------------------------
-- 26.07.2002 	New:
--		#57604, 2xWebThermometer
--		#57603, 8xWebThermometer
-- 		


    IMPORTS

    OBJECT-TYPE                                        FROM RFC-1212
    TRAP-TYPE                                          FROM RFC-1215
    DisplayString, PhysAddress                         FROM RFC1213-MIB
    enterprises, TimeTicks, IpAddress, NetworkAddress  FROM RFC1155-SMI;

 
--    IpAddress ::=
--        [APPLICATION 0]
--            IMPLICIT OCTET STRING (SIZE (4))
--    Counter ::=
--        [APPLICATION 1]
--            IMPLICIT INTEGER (0..4294967295)
--    Gauge ::=
--        [APPLICATION 2]
--            IMPLICIT INTEGER (0..4294967295)
--    TimeTicks ::=
--        [APPLICATION 3]
--            IMPLICIT INTEGER (0..4294967295)


--    DisplayString ::= OCTET STRING
--    PhysAddress   ::= OCTET STRING

--    internet         OBJECT IDENTIFIER ::= { iso org(3) dod(6) 1 }
--    privat           OBJECT IDENTIFIER ::= { internet 4 }
--    enterprises      OBJECT IDENTIFIER ::= { privat 1 }



--  Wiesemann & Theis Com-Server MIB

    wut                		OBJECT IDENTIFIER ::= { enterprises 5040 }
    wtComServer        		OBJECT IDENTIFIER ::= { wut 1 }
    wtWebio            		OBJECT IDENTIFIER ::= { wtComServer 2 }

--  wtWebio Tree

    wtWebioAn1Graph    		OBJECT IDENTIFIER ::= { wtWebio 8 }
    
--  wtWebioAn1Graph Tree

    wtWebioAn1GraphTemp      	OBJECT IDENTIFIER ::= { wtWebioAn1Graph 1 }
    wtWebioAn1GraphSessCntrl 	OBJECT IDENTIFIER ::= { wtWebioAn1Graph 2 }
    wtWebioAn1GraphConfig    	OBJECT IDENTIFIER ::= { wtWebioAn1Graph 3 }
    
--  wtWebioAn1GraphConfig Tree

    wtWebioAn1GraphDevice    	OBJECT IDENTIFIER ::= { wtWebioAn1GraphConfig 1 }
    wtWebioAn1GraphPorts     	OBJECT IDENTIFIER ::= { wtWebioAn1GraphConfig 2 }	
    wtWebioAn1GraphManufact  	OBJECT IDENTIFIER ::= { wtWebioAn1GraphConfig 3 }
    wtWebioAn1GraphDiag      	OBJECT IDENTIFIER ::= { wtWebioAn1GraphConfig 4 }

--  wtWebioAn1GraphDevice Tree

    wtWebioAn1GraphText		OBJECT IDENTIFIER ::= { wtWebioAn1GraphDevice 1 }	
    wtWebioAn1GraphTimeDate 	OBJECT IDENTIFIER ::= { wtWebioAn1GraphDevice 2 }
    wtWebioAn1GraphBasic	OBJECT IDENTIFIER ::= { wtWebioAn1GraphDevice 3 }	
    wtWebioAn1GraphDatalogger	OBJECT IDENTIFIER ::= { wtWebioAn1GraphDevice 4 }	
    wtWebioAn1GraphAlarm	OBJECT IDENTIFIER ::= { wtWebioAn1GraphDevice 5 }
    
--  wtWebioAn1GraphTimeDate Tree

    wtWebioAn1GraphTimeZone	OBJECT IDENTIFIER ::= { wtWebioAn1GraphTimeDate 1 }
    wtWebioAn1GraphTimeServer	OBJECT IDENTIFIER ::= { wtWebioAn1GraphTimeDate 2 }	
    wtWebioAn1GraphDeviceClock	OBJECT IDENTIFIER ::= { wtWebioAn1GraphTimeDate 3 }

--  wtWebioAn1GraphBasic Tree
    
    wtWebioAn1GraphNetwork	OBJECT IDENTIFIER ::= { wtWebioAn1GraphBasic 1 }
    wtWebioAn1GraphHTML		OBJECT IDENTIFIER ::= { wtWebioAn1GraphBasic 2 }
    wtWebioAn1GraphMail		OBJECT IDENTIFIER ::= { wtWebioAn1GraphBasic 3 }	
    wtWebioAn1GraphSNMP		OBJECT IDENTIFIER ::= { wtWebioAn1GraphBasic 4 }
    wtWebioAn1GraphUDP		OBJECT IDENTIFIER ::= { wtWebioAn1GraphBasic 5 }
    wtWebioAn1GraphSyslog	OBJECT IDENTIFIER ::= { wtWebioAn1GraphBasic 6 }    
    wtWebioAn1GraphFTP		OBJECT IDENTIFIER ::= { wtWebioAn1GraphBasic 7 }
    wtWebioAn1GraphHTTP		OBJECT IDENTIFIER ::= { wtWebioAn1GraphBasic 8 }
       
-- wtWebioAn1GraphTemp Group
------------------------

wtWebioAn1GraphSensors OBJECT-TYPE
    SYNTAX INTEGER (1..8)
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Number of temperature sensors"
    ::= { wtWebioAn1GraphTemp 1 }

-- Interface Table

wtWebioAn1GraphSensorTable OBJECT-TYPE
    SYNTAX SEQUENCE OF WtWebioAn1GraphSensorEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "List of sensors."
    ::= { wtWebioAn1GraphTemp 2 }

wtWebioAn1GraphSensorEntry OBJECT-TYPE
    SYNTAX WtWebioAn1GraphSensorEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "Temperature sensor numbers."
    INDEX  { wtWebioAn1GraphSensorNo }
    ::= { wtWebioAn1GraphSensorTable 1 }

WtWebioAn1GraphSensorEntry ::= SEQUENCE {
    wtWebioAn1GraphSensorNo INTEGER
}

wtWebioAn1GraphSensorNo OBJECT-TYPE
    SYNTAX INTEGER (1)
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Temperature sensor number."
    ::= { wtWebioAn1GraphSensorEntry 1 }


-- wtWebioAn1GraphTempValue Table

wtWebioAn1GraphTempValueTable OBJECT-TYPE
    SYNTAX SEQUENCE OF WtWebioAn1GraphTempValueEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "List of temperature values corresponding to the channel numbers."
    ::= { wtWebioAn1GraphTemp 3 }

wtWebioAn1GraphTempValueEntry OBJECT-TYPE
    SYNTAX WtWebioAn1GraphTempValueEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "Temperatures of the sensors."
    INDEX  { wtWebioAn1GraphSensorNo }
    ::= { wtWebioAn1GraphTempValueTable 1 }

WtWebioAn1GraphTempValueEntry ::= SEQUENCE{
    wtWebioAn1GraphTempValue OCTET STRING
}

wtWebioAn1GraphTempValue OBJECT-TYPE
    SYNTAX OCTET STRING (SIZE (5))
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Temperature value of the sensor, ASCII, 5 characters in length."
    ::= { wtWebioAn1GraphTempValueEntry 1 }

-- wtWebioAn1GraphBinaryTempValue Table

wtWebioAn1GraphBinaryTempValueTable OBJECT-TYPE
    SYNTAX SEQUENCE OF WtWebioAn1GraphBinaryTempValueEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "List of binary temperature values corresponding to the channel numbers."
    ::= { wtWebioAn1GraphTemp 4 }

wtWebioAn1GraphBinaryTempValueEntry OBJECT-TYPE
    SYNTAX WtWebioAn1GraphBinaryTempValueEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "Binary temperature values of the sensors."
    INDEX  { wtWebioAn1GraphSensorNo }
    ::= { wtWebioAn1GraphBinaryTempValueTable 1 }

WtWebioAn1GraphBinaryTempValueEntry ::= SEQUENCE{
    wtWebioAn1GraphBinaryTempValue INTEGER
}    

wtWebioAn1GraphBinaryTempValue OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Binary temperature value of the sensor in 1/10 degrees Celsius,
        signed number, 0x7FFF indicates an 
        invalid measured value."
    ::= { wtWebioAn1GraphBinaryTempValueEntry 1 }

-- wtWebioAn1GraphSessCntrl Group
--------------------------------

wtWebioAn1GraphSessCntrlPassword OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Entering this password opens a session which is ended by writing a 1 to 
        wtWebioAn1GraphSessCntrlLogout. When read this variable provides a string of
        length zero."
    ::= { wtWebioAn1GraphSessCntrl 1 }

wtWebioAn1GraphSessCntrlConfigMode OBJECT-TYPE
    SYNTAX INTEGER {
    wtWebioAn1GraphSessCntrl-NoSession(0),
    wtWebioAn1GraphSessCntrl-Session(1)
    }
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "When the device is in SNMP configuration mode, the value 1 is
        returned, otherwise 0. If the read value is 0 even though the
        password was written, the device is already in config mode and the
        variables can only be read."
    ::= { wtWebioAn1GraphSessCntrl 2 }

wtWebioAn1GraphSessCntrlLogout OBJECT-TYPE
    SYNTAX INTEGER 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "If the device is in configuration mode and the session was opened by
        this SNMP Manager, writing a 1 to this variable will end the session 
        and all parameters are stored.
        Writing a 2 discards all entries again.
        When read this variable provides the value 0."
    ::= { wtWebioAn1GraphSessCntrl 3 }

wtWebioAn1GraphSessCntrlAdminPassword OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "This password protects access to the variables with administrator rights.
        It can only be changed by the administrator. If no password was assigned,
        the valid password is public."
    ::= { wtWebioAn1GraphSessCntrl 4 }

wtWebioAn1GraphSessCntrlConfigPassword OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "This password protects access to the variables with configurator rights. It can
        be changed by the administrator and by the configurator. If no password was assigned, 
        the valid password is public. When read this variable provides a null-pointer."
    ::= { wtWebioAn1GraphSessCntrl 5 }
    

-- wtWebioAn1GraphText Group
------------------------

wtWebioAn1GraphDeviceName OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Name of the Webio, which is user definable."
    ::= { wtWebioAn1GraphText 1 }

wtWebioAn1GraphDeviceText OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Description of the Webio, which is user definable."
    ::= { wtWebioAn1GraphText 2 }

wtWebioAn1GraphDeviceLocation OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Description of the location of the Webio, which is user definable."
    ::= { wtWebioAn1GraphText 3 }

wtWebioAn1GraphDeviceContact OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Contact address of the system operator of the Webio, which is user definable."
    ::= { wtWebioAn1GraphText 4 }

-- wtWebioAn1GraphTimeZone Group
----------------------------

wtWebioAn1GraphTzOffsetHrs OBJECT-TYPE
    SYNTAX INTEGER 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Offset hours for the time zone (winter time) with respect to UTC."
    ::= { wtWebioAn1GraphTimeZone 1 }

wtWebioAn1GraphTzOffsetMin OBJECT-TYPE
    SYNTAX INTEGER 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Offset minutes for the time zone (winter time) with respect to UTC."
    ::= { wtWebioAn1GraphTimeZone 2 }

wtWebioAn1GraphTzEnable OBJECT-TYPE
    SYNTAX OCTET STRING (SIZE(4))
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Binary coded conditions:
        Octet 1: unused
        Octet 2: unused
        Octet 3: unused
        Octet 4:
        	Bit 1-7: unused
	        Bit 0  : Apply Timezone"
    ::= { wtWebioAn1GraphTimeZone 3 }    
    
wtWebioAn1GraphStTzOffsetHrs OBJECT-TYPE
    SYNTAX INTEGER 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Offset hours of the time zone (summer time) with respect to UTC."
    ::= { wtWebioAn1GraphTimeZone 4 }

wtWebioAn1GraphStTzOffsetMin OBJECT-TYPE
    SYNTAX INTEGER 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Offset minutes of the time zone (summer time) with respect to UTC."
    ::= { wtWebioAn1GraphTimeZone 5 }
    
wtWebioAn1GraphStTzEnable OBJECT-TYPE
    SYNTAX OCTET STRING (SIZE(4))
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Binary coded conditions:
        Octet 1: unused
        Octet 2: unused
        Octet 3: unused
        Octet 4:
        	Bit 1-7: unused
	        Bit 0  : Apply Summertime"
    ::= { wtWebioAn1GraphTimeZone 6 }       
    
wtWebioAn1GraphStTzStartMonth OBJECT-TYPE
    SYNTAX INTEGER {
    	wtWebioAn1GraphStartMonth-January(1),
    	wtWebioAn1GraphStartMonth-February(2),
    	wtWebioAn1GraphStartMonth-March(3),
    	wtWebioAn1GraphStartMonth-April(4),
    	wtWebioAn1GraphStartMonth-May(5),
    	wtWebioAn1GraphStartMonth-June(6),
    	wtWebioAn1GraphStartMonth-July(7),
    	wtWebioAn1GraphStartMonth-August(8),
    	wtWebioAn1GraphStartMonth-September(9),
    	wtWebioAn1GraphStartMonth-October(10),
    	wtWebioAn1GraphStartMonth-November(11),
    	wtWebioAn1GraphStartMonth-December(12)
    	}
    	
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Month in which the change is made from winter time to summer time."
    ::= { wtWebioAn1GraphTimeZone 7 }

wtWebioAn1GraphStTzStartMode OBJECT-TYPE
    SYNTAX INTEGER {
    	wtWebioAn1GraphStartMode-first(1),
    	wtWebioAn1GraphStartMode-second(2),
    	wtWebioAn1GraphStartMode-third(3),
    	wtWebioAn1GraphStartMode-fourth(4),
    	wtWebioAn1GraphStartMode-last(5)
    	}
    	
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Mode of the day of the week for which the change is made from winter time to summer time."
    ::= { wtWebioAn1GraphTimeZone 8 }

wtWebioAn1GraphStTzStartWday OBJECT-TYPE
    SYNTAX INTEGER {
    	wtWebioAn1GraphStartWday-Sunday(1),
    	wtWebioAn1GraphStartWday-Monday(2),
    	wtWebioAn1GraphStartWday-Tuesday(3),
    	wtWebioAn1GraphStartWday-Thursday(4),
    	wtWebioAn1GraphStartWday-Wednesday(5),
    	wtWebioAn1GraphStartWday-Friday(6),
    	wtWebioAn1GraphStartWday-Saturday(7)
    	}
    	
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Day of the week on which the change is made from winter time to summer time"
    ::= { wtWebioAn1GraphTimeZone 9 }
    
wtWebioAn1GraphStTzStartHrs OBJECT-TYPE
    SYNTAX INTEGER 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Hour in which the time zone is changed from winter to summer time with
        respect to UTC."
    ::= { wtWebioAn1GraphTimeZone 10 }

wtWebioAn1GraphStTzStartMin OBJECT-TYPE
    SYNTAX INTEGER 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Minute in which the time zone is changed from winter to summer time with
        respect to UTC."
    ::= { wtWebioAn1GraphTimeZone 11 }
 
wtWebioAn1GraphStTzStopMonth OBJECT-TYPE
    SYNTAX INTEGER {
    	wtWebioAn1GraphStopMonth-January(1),
    	wtWebioAn1GraphStopMonth-February(2),
    	wtWebioAn1GraphStopMonth-March(3),
    	wtWebioAn1GraphStopMonth-April(4),
    	wtWebioAn1GraphStopMonth-May(5),
    	wtWebioAn1GraphStopMonth-June(6),
    	wtWebioAn1GraphStopMonth-July(7),
    	wtWebioAn1GraphStopMonth-August(8),
    	wtWebioAn1GraphStopMonth-September(9),
    	wtWebioAn1GraphStopMonth-October(10),
    	wtWebioAn1GraphStopMonth-November(11),
    	wtWebioAn1GraphStopMonth-December(12)
    	}
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Month in which the change is made from summer time to winter time."
   ::= { wtWebioAn1GraphTimeZone 12 }

wtWebioAn1GraphStTzStopMode OBJECT-TYPE
    SYNTAX INTEGER {
    	wtWebioAn1GraphStopMode-first(1),
    	wtWebioAn1GraphStopMode-second(2),
    	wtWebioAn1GraphStopMode-third(3),
    	wtWebioAn1GraphStopMode-fourth(4),
    	wtWebioAn1GraphStopMode-last(5)
    	}
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Mode of the week day on which the change is made from summer time to winter time."
    ::= { wtWebioAn1GraphTimeZone 13 }

wtWebioAn1GraphStTzStopWday OBJECT-TYPE
    SYNTAX INTEGER {
    	wtWebioAn1GraphStopWday-Sunday(1),
    	wtWebioAn1GraphStopWday-Monday(2),
    	wtWebioAn1GraphStopWday-Tuesday(3),
    	wtWebioAn1GraphStopWday-Thursday(4),
    	wtWebioAn1GraphStopWday-Wednesday(5),
    	wtWebioAn1GraphStopWday-Friday(6),
    	wtWebioAn1GraphStopWday-Saturday(7)
    	}
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Day of the week on which the change is made from summer time to winter time."
    ::= { wtWebioAn1GraphTimeZone 14 }
    
wtWebioAn1GraphStTzStopHrs OBJECT-TYPE
    SYNTAX INTEGER 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Hour at which the time zone is changed from summer to winter time with
        respect to UTC."
    ::= { wtWebioAn1GraphTimeZone 15 }

wtWebioAn1GraphStTzStopMin OBJECT-TYPE
    SYNTAX INTEGER 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Minute at which the time zone is changed from summer to winter time with
        respect to UTC."
    ::= { wtWebioAn1GraphTimeZone 16 }

-- wtWebioAn1GraphTimeServer Group
----------------------------

wtWebioAn1GraphTimeServer1 OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "IP address or name of the 1st time server in ASCII"
    ::= { wtWebioAn1GraphTimeServer 1 }

wtWebioAn1GraphTimeServer2 OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "IP address or name of the 2nd time server in ASCII"
    ::= { wtWebioAn1GraphTimeServer 2 }
    
wtWebioAn1GraphTsEnable OBJECT-TYPE
    SYNTAX OCTET STRING (SIZE(4))
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Binary coded conditions:
        Octet 1: unused
        Octet 2: unused
        Octet 3: unused
        Octet 4:
        	Bit 1-7: unused
	        Bit 0  : Apply Time Server"
    ::= { wtWebioAn1GraphTimeServer 3 }
    
wtWebioAn1GraphTsSyncTime OBJECT-TYPE
    SYNTAX INTEGER 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Daily synchronisation time with the time server (hour: 0-23)."
    ::= { wtWebioAn1GraphTimeServer 4 } 
    
-- wtWebioAn1GraphDeviceClock Group
----------------------------

wtWebioAn1GraphClockHrs OBJECT-TYPE
    SYNTAX INTEGER (0..23)
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Clock hours taking into account the time zone settings."
    ::= { wtWebioAn1GraphDeviceClock 1 }

wtWebioAn1GraphClockMin OBJECT-TYPE
    SYNTAX INTEGER (0..59)
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Clock minutes taking into account the time zone settings."
    ::= { wtWebioAn1GraphDeviceClock 2 }

wtWebioAn1GraphClockDay OBJECT-TYPE
    SYNTAX INTEGER (1..31)
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Date: Day of the month, taking into account the time zone settings."
    ::= { wtWebioAn1GraphDeviceClock 3 }

wtWebioAn1GraphClockMonth OBJECT-TYPE
   SYNTAX INTEGER {
    	wtWebioAn1GraphClockMonth-January(1),
    	wtWebioAn1GraphClockMonth-February(2),
    	wtWebioAn1GraphClockMonth-March(3),
    	wtWebioAn1GraphClockMonth-April(4),
    	wtWebioAn1GraphClockMonth-May(5),
    	wtWebioAn1GraphClockMonth-June(6),
    	wtWebioAn1GraphClockMonth-July(7),
    	wtWebioAn1GraphClockMonth-August(8),
    	wtWebioAn1GraphClockMonth-September(9),
    	wtWebioAn1GraphClockMonth-October(10),
    	wtWebioAn1GraphClockMonth-November(11),
    	wtWebioAn1GraphClockMonth-December(12)
    	}
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Date: Month, taking into account the time zone settings."
    ::= { wtWebioAn1GraphDeviceClock 4 }

wtWebioAn1GraphClockYear OBJECT-TYPE
    SYNTAX INTEGER (0..65535)
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Date: Year, taking into account the time zone settings."
    ::= { wtWebioAn1GraphDeviceClock 5 }
    

-- wtWebioAn1GraphNetwork Group
------------------------

wtWebioAn1GraphIpAddress OBJECT-TYPE
    SYNTAX IpAddress
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "IP address of the Webio"
    ::= { wtWebioAn1GraphNetwork 1 }

wtWebioAn1GraphSubnetMask OBJECT-TYPE
    SYNTAX IpAddress
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Subnet mask of the Webio"
    ::= { wtWebioAn1GraphNetwork 2 }

wtWebioAn1GraphGateway OBJECT-TYPE
    SYNTAX IpAddress
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Gateway of the Webio"
    ::= { wtWebioAn1GraphNetwork 3 }

wtWebioAn1GraphDnsServer1 OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "IP address of the 1st DNS server in ASCII"
    ::= { wtWebioAn1GraphNetwork 4 }

wtWebioAn1GraphDnsServer2 OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "IP address of the 2nd DNS server in ASCII"
    ::= { wtWebioAn1GraphNetwork 5 }

wtWebioAn1GraphAddConfig OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Additional configuration (1=ON):
        Octet 1: unused
        Octet 2: unused
        Octet 3: unused
        Octet 4:
	        Bit 0: BOOTP disable
	        "
    ::= { wtWebioAn1GraphNetwork 6 }

--  wtWebioAn1GraphHTTP Group
--------------------------------

wtWebioAn1GraphStartup OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Binary coded start page:
        Octet 1: unused
        Octet 2: unused
        Octet 3: unused
        Octet 4:
	        Bit 1: Index.htm
	        Bit 2: Home.htm
	        Bit 3: User.htm
	Only one page may be selected at a time."
    ::= { wtWebioAn1GraphHTTP 1 }

wtWebioAn1GraphGetHeaderEnable OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "If this bit is set, every answer of a short form GET question will be lead
        by the IP-address and name of the device:
        Octet 1: unused
        Octet 2: unused
        Octet 3: unused
        Octet 4:
        	Bit 1-7: unused
                Bit 0  : GET Header enable"
    ::= { wtWebioAn1GraphHTTP 2 }  
    
wtWebioAn1GraphHttpPort OBJECT-TYPE
    SYNTAX INTEGER (1..65535)
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Definition of the standard HTML port (Default: 80)."
    ::= { wtWebioAn1GraphHTTP 3 }    


-- wtWebioAn1GraphMail Group
--------------------------------

wtWebioAn1GraphMailAdName OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Device name for mail administration."
    ::= { wtWebioAn1GraphMail 1 }
    
wtWebioAn1GraphMailReply OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Reply address for the mail server."
    ::= { wtWebioAn1GraphMail 2 }
    
wtWebioAn1GraphMailServer OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Name or IP address of the mail server."
    ::= { wtWebioAn1GraphMail 3 }
    
wtWebioAn1MailEnable OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Set this bit to enable the sending of mails:
        Octet 1: unused
        Octet 2: unused
        Octet 3: unused
        Octet 4:
        	Bit 1-7: unused
                Bit 0  : Mail enable"
    ::= { wtWebioAn1GraphMail 4 }
    
wtWebioAn1GraphMailAuthentication OBJECT-TYPE
    SYNTAX OCTET STRING (SIZE (4))
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Selection of the authentication modi:
        The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. 
        Bit 0 corresponds to the LSB.
        OCTET 1: unused
        OCTET 2: unused
        OCTET 3: unused
        OCTET 4: Bit 3-7: unused
        	 Bit 2  : POP3 before SMTP
        	 Bit 1  : ESMTP, authentication
        	 Bit 0  : SMTP, no authentication"
    ::= { wtWebioAn1GraphMail 5 }
    
wtWebioAn1GraphMailAuthUser OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Name of the user to be authenticated."
    ::= { wtWebioAn1GraphMail 6 }    
    
wtWebioAn1GraphMailAuthPassword OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Authentication password."
    ::= { wtWebioAn1GraphMail 7 }    
    
wtWebioAn1GraphMailPop3Server OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Name or Ip-address of the POP3 Servers."
    ::= { wtWebioAn1GraphMail 8 }        
    

-- wtWebioAn1GraphSNMP Group
--------------------------------

wtWebioAn1GraphSnmpCommunityStringRead OBJECT-TYPE
    SYNTAX OCTET STRING
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Community string read only"
    ::= { wtWebioAn1GraphSNMP 1 }

wtWebioAn1GraphSnmpCommunityStringReadWrite OBJECT-TYPE
    SYNTAX OCTET STRING
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Community string read / write"
    ::= { wtWebioAn1GraphSNMP 2 }

wtWebioAn1GraphSystemTrapManagerIP OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Name or IP address of the TCP server which accepts the system trap."
    ::= { wtWebioAn1GraphSNMP 3 }
    
wtWebioAn1GraphSystemTrapEnable OBJECT-TYPE
    SYNTAX OCTET STRING (SIZE(4))
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Binary coded trigger conditions:
        Octet 1: unused
        Octet 2: unused
        Octet 3: unused
        Octet 4:
	        Bit 0:   ColdStart
	        Bit 1:   WarmStart
	        Bit 2-7: unused"
    ::= { wtWebioAn1GraphSNMP 4 }
    
wtWebioAn1GraphSnmpEnable OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Set bit 0 to enable SNMP.
        If disabled, the device did not respond to any SNMP requests.
        Bit 1 decided wether the community string of read operations 
        is compared with the system password or not:
        Octet 1: unused
        Octet 2: unused
        Octet 3: unused
        Octet 4:
        	Bit 1-7: unused
        	Bit 0  : SNMP enable"
    ::= { wtWebioAn1GraphSNMP 5 }

wtWebioAn1GraphSnmpCommunityStringTrap OBJECT-TYPE
    SYNTAX OCTET STRING
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Community string of the traps."
    ::= { wtWebioAn1GraphSNMP 6 }    
        
-- wtWebioAn1GraphUDP Group
--------------------------------
    
wtWebioAn1GraphUdpPort OBJECT-TYPE
    SYNTAX INTEGER (1..65535)
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Udp port to which the Udp queries ( short form GET requests) can be sent. This
        port number must be unique within the device."
    ::= { wtWebioAn1GraphUDP 1 }
    
wtWebioAn1GraphUdpEnable OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Set this bit to enable UDP support:
        Octet 1: unused
        Octet 2: unused
        Octet 3: unused
        Octet 4:
        	Bit 1-7: unused
                Bit 0  : UDP enable"
    ::= { wtWebioAn1GraphUDP 2 }

    
--  wtWebioAn1GraphSyslog Group
--------------------------------
    
wtWebioAn1GraphSyslogServerIP OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Name or IP address of the Syslog server, which accepts the Syslog messgaes."
    ::= { wtWebioAn1GraphSyslog 1 }
    
wtWebioAn1GraphSyslogServerPort OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Portnumber of the Syslog servers, default 514."
    ::= { wtWebioAn1GraphSyslog 2 }

wtWebioAn1GraphSyslogSystemMessagesEnable OBJECT-TYPE
    SYNTAX OCTET STRING (SIZE(4))
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Binary coded trigger conditions:
        Octet 1: unused
        Octet 2: unused
        Octet 3: unused
        Octet 4:
	        Bit 0:   ColdStart
	        Bit 1:   WarmStart
	        Bit 2:   Diag Messages
	        Bit 3-7: unused"
    ::= { wtWebioAn1GraphSyslog 3 }    

wtWebioAn1GraphSyslogEnable OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Set bit 0 to enable Syslog:
        Octet 1: unused
        Octet 2: unused
        Octet 3: unused
        Octet 4:
        	Bit 1-7: unused
                Bit 0  : Syslog enable"
    ::= { wtWebioAn1GraphSyslog 4 }
    
--  wtWebioAn1GraphFTP Group
--------------------------------

wtWebioAn1GraphFTPServerIP OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Name or IP address of the FTP server, which accepts the FTP messages."
    ::= { wtWebioAn1GraphFTP 1 }
    
wtWebioAn1GraphFTPServerControlPort OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Portnumber of the control port of the FTP server, default 21."
    ::= { wtWebioAn1GraphFTP 2 }
    
wtWebioAn1GraphFTPUserName OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "FTP Loggin: user name."
    ::= { wtWebioAn1GraphFTP 3 }
    
wtWebioAn1GraphFTPPassword OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "FTP Loggin: user password."
    ::= { wtWebioAn1GraphFTP 4 }

wtWebioAn1GraphFTPAccount OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "FTP Loggin: name of account."
    ::= { wtWebioAn1GraphFTP 5 }

wtWebioAn1GraphFTPOption OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Bit 0 switches the FTP Server in Passiv-Mode,
        the Client controls the data connection on its own:
        Octet 1: unused
        Octet 2: unused
        Octet 3: unused
        Octet 4:
        	Bit 1-7: unused
                Bit 0  : PASV enable"
    ::= { wtWebioAn1GraphFTP 6 }
    
wtWebioAn1GraphFTPEnable OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Set Bit 0 to enable FTP:
        Octet 1: unused
        Octet 2: unused
        Octet 3: unused
        Octet 4:
        	Bit 1-7: unused
                Bit 0  : FTP enable"
    ::= { wtWebioAn1GraphFTP 7 }
    
-- wtWebioAn1GraphDatalogger Group
--------------------------------

wtWebioAn1GraphLoggerTimebase OBJECT-TYPE
    SYNTAX INTEGER {
    wtWebioAn1GraphDatalogger-1Min(1),
    wtWebioAn1GraphDatalogger-5Min(2),
    wtWebioAn1GraphDatalogger-15Min(3),
    wtWebioAn1GraphDatalogger-60Min(4)
    }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Time base of the data logger"
    ::= { wtWebioAn1GraphDatalogger 1 }

wtWebioAn1GraphLoggerSensorSel OBJECT-TYPE
    SYNTAX OCTET STRING (SIZE(4))
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Binary coded trigger conditions:
        Octet 1: unused
        Octet 2: unused
        Octet 3: unused
        Octet 4:
        	Bit 0: Sensor 1
        	Bit 1: Sensor 2
        	Bit 2: Sensor 3
        	Bit 3: Sensor 4
        	Bit 4: Sensor 5
        	Bit 5: Sensor 6
        	Bit 6: Sensor 7
        	Bit 7: Sensor 8"
    ::= { wtWebioAn1GraphDatalogger 2 }

wtWebioAn1GraphDisplaySensorSel OBJECT-TYPE
    SYNTAX OCTET STRING (SIZE(4))
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Binary coded sensor selection:
        only selected sensors will be shown in the graphical presentation:
        Octet 1: unused
        Octet 2: unused
        Octet 3: unused
        Octet 4:
        	Bit 0: Sensor 1
        	Bit 1: Sensor 2
        	Bit 2: Sensor 3
        	Bit 3: Sensor 4
        	Bit 4: Sensor 5
        	Bit 5: Sensor 6
        	Bit 6: Sensor 7
        	Bit 7: Sensor 8"
    ::= { wtWebioAn1GraphDatalogger 3 }    
    
-- Graph Sensor Color Table

wtWebioAn1GraphSensorColorTable OBJECT-TYPE
    SYNTAX SEQUENCE OF WtWebioAn1GraphSensorColorEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "List of sensor colors for the praphical presentation."
    ::= { wtWebioAn1GraphDatalogger 4 }

wtWebioAn1GraphSensorColorEntry OBJECT-TYPE
    SYNTAX WtWebioAn1GraphSensorColorEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "Index numbers of the sensors."
    INDEX  { wtWebioAn1GraphSensorNo }
    ::= { wtWebioAn1GraphSensorColorTable 1 }

WtWebioAn1GraphSensorColorEntry ::= SEQUENCE {
    wtWebioAn1GraphSensorColor OCTET STRING
}

wtWebioAn1GraphSensorColor OBJECT-TYPE
    SYNTAX OCTET STRING (SIZE(3))
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Color of the sensors at the praphical presention."
    ::= { wtWebioAn1GraphSensorColorEntry 1 }
    
wtWebioAn1GraphAutoScaleEnable OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "If bit 0 is set, vertical auto scale is enabled:
        Octet 1: unused
        Octet 2: unused
        Octet 3: unused
        Octet 4:
        	Bit 1-7: unused
                Bit 0  : Auto Scale enable"
    ::= { wtWebioAn1GraphDatalogger 5 }
    
wtWebioAn1GraphVerticalUpperLimit OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "This value defines the maximum temperature shown in the graphical presentation,
        if no auto scaling is selected.
        Temperature in degrees with maximum 2 decimal places."
    ::= { wtWebioAn1GraphDatalogger 6 }

wtWebioAn1GraphVerticalLowerLimit OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "This value defines the minimum temperature shown in the graphical presentation,
        if no auto scaling is selected.
        Temperature in degrees with maximum 2 decimal places."
    ::= { wtWebioAn1GraphDatalogger 7 }
    
wtWebioAn1GraphHorizontalZoom OBJECT-TYPE
    SYNTAX INTEGER {
    wtWebioAn1GraphZoom-25min(1),
    wtWebioAn1GraphZoom-75min(2),
    wtWebioAn1GraphZoom-5hrs(3),
    wtWebioAn1GraphZoom-30hrs(4),
    wtWebioAn1GraphZoom-5days(5),
    wtWebioAn1GraphZoom-25days(6)
    }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Defines the default zoom stage, if no auto scaling is selected."
    ::= { wtWebioAn1GraphDatalogger 8 }    

-- wtWebioAn1GraphAlarm Group
----------------------------

wtWebioAn1GraphAlarmCount OBJECT-TYPE
    SYNTAX INTEGER (1..8)
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Number of independent alarms."
    ::= { wtWebioAn1GraphAlarm 1 }
    
-- Alarm Interface Table

wtWebioAn1GraphAlarmIfTable OBJECT-TYPE
    SYNTAX SEQUENCE OF WtWebioAn1GraphAlarmIfEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "List of alarm indices."
    ::= { wtWebioAn1GraphAlarm 2 }

wtWebioAn1GraphAlarmIfEntry OBJECT-TYPE
    SYNTAX WtWebioAn1GraphAlarmIfEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "Numbers of the alarms."
    INDEX  { wtWebioAn1GraphAlarmNo }
    ::= { wtWebioAn1GraphAlarmIfTable 1 }

WtWebioAn1GraphAlarmIfEntry ::= SEQUENCE {
    wtWebioAn1GraphAlarmNo INTEGER
}

wtWebioAn1GraphAlarmNo OBJECT-TYPE
    SYNTAX INTEGER (1..8)
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Alarm number."
    ::= { wtWebioAn1GraphAlarmIfEntry 1 }

-- Alarm Table

wtWebioAn1GraphAlarmTable OBJECT-TYPE
    SYNTAX SEQUENCE OF WtWebioAn1GraphAlarmEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "List of settings depending on the alarm number."
    ::= { wtWebioAn1GraphAlarm 3 }

wtWebioAn1GraphAlarmEntry OBJECT-TYPE
    SYNTAX WtWebioAn1GraphAlarmEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "Alarm parameters of the individual alarms."
    INDEX  { wtWebioAn1GraphAlarmNo }
    ::= { wtWebioAn1GraphAlarmTable 1 }

WtWebioAn1GraphAlarmEntry ::= SEQUENCE {
    wtWebioAn1GraphAlarmTrigger			OCTET STRING,
    wtWebioAn1GraphAlarmMin			OCTET STRING,
    wtWebioAn1GraphAlarmMax			OCTET STRING,
    wtWebioAn1GraphAlarmHysteresis		OCTET STRING,
    wtWebioAn1GraphAlarmDelay			OCTET STRING,
    wtWebioAn1GraphAlarmInterval		OCTET STRING,
    wtWebioAn1GraphAlarmEnable			OCTET STRING,
    wtWebioAn1GraphAlarmEMailAddr		OCTET STRING,
    wtWebioAn1GraphAlarmMailSubject		OCTET STRING,
    wtWebioAn1GraphAlarmMailText		OCTET STRING,
    wtWebioAn1GraphAlarmManagerIP		OCTET STRING,
    wtWebioAn1GraphAlarmTrapText		OCTET STRING,
    wtWebioAn1GraphAlarmMailOptions		OCTET STRING,
    wtWebioAn1GraphAlarmTcpIpAddr		OCTET STRING,
    wtWebioAn1GraphAlarmTcpPort			INTEGER,
    wtWebioAn1GraphAlarmTcpText			OCTET STRING,
    wtWebioAn1GraphAlarmClearMailSubject	OCTET STRING,
    wtWebioAn1GraphAlarmClearMailText		OCTET STRING,
    wtWebioAn1GraphAlarmClearTrapText		OCTET STRING,
    wtWebioAn1GraphAlarmClearTcpText		OCTET STRING,    
    wtWebioAn1GraphAlarmSyslogIpAddr		OCTET STRING,
    wtWebioAn1GraphAlarmSyslogPort		INTEGER,
    wtWebioAn1GraphAlarmSyslogText		OCTET STRING,
    wtWebioAn1GraphAlarmFtpDataPort		OCTET STRING,
    wtWebioAn1GraphAlarmFtpFileName		OCTET STRING,
    wtWebioAn1GraphAlarmFtpText			OCTET STRING,
    wtWebioAn1GraphAlarmFtpClearText		OCTET STRING,
    wtWebioAn1GraphAlarmFtpOption		OCTET STRING,
    wtWebioAn1GraphAlarmTimerCron		OCTET STRING
    
}

wtWebioAn1GraphAlarmTrigger OBJECT-TYPE
    SYNTAX OCTET STRING (SIZE(4))
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Binary coded trigger conditions:
        Octet 1: unused
        Octet 2: unused
        Octet 3:
        	Bit 0: Timer
        	Bit 1: ColdStart
        	Bit 2: WarmStart
        	
        Octet 4:
        	Bit 0: Sensor 1
        	Bit 1: Sensor 2
        	Bit 2: Sensor 3
        	Bit 3: Sensor 4
        	Bit 4: Sensor 5
        	Bit 5: Sensor 6
        	Bit 6: Sensor 7
        	Bit 7: Sensor 8"
    ::= { wtWebioAn1GraphAlarmEntry 1 }

wtWebioAn1GraphAlarmMin OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Minimum temperature in degrees with maximum 2 decimal places."
    ::= { wtWebioAn1GraphAlarmEntry 2 }

wtWebioAn1GraphAlarmMax OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Maximum temperature in degrees with maximum 2 decimal places."
    ::= { wtWebioAn1GraphAlarmEntry 3 }
    
wtWebioAn1GraphAlarmHysteresis OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
        , in degrees with maximum 2 decimal places."
    ::= { wtWebioAn1GraphAlarmEntry 4 }

wtWebioAn1GraphAlarmDelay OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Alarm will be delayed by setting this time while stable alarm 
        condition occur (time in minutes)."
    ::= { wtWebioAn1GraphAlarmEntry 5 }
        

wtWebioAn1GraphAlarmInterval OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Send interval for alarm messages."
    ::= { wtWebioAn1GraphAlarmEntry 6 }

wtWebioAn1GraphAlarmEnable OBJECT-TYPE
    SYNTAX OCTET STRING (SIZE(4))
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Binary coded alarm enable:
        Octet 1: unused
        Octet 2: unused
        Octet 3: unused
        Octet 4:
		Bit 0:	Mail Enable
        	Bit 1:	SNMP Trap enable
        	Bit 2:  TCP Client enable"
    ::= { wtWebioAn1GraphAlarmEntry 7 }

wtWebioAn1GraphAlarmEMailAddr OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "E-Mail address for sending the alarm mail to."
    ::= { wtWebioAn1GraphAlarmEntry 8 }

wtWebioAn1GraphAlarmMailSubject OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Subject line for alarm mail."
    ::= { wtWebioAn1GraphAlarmEntry 9 }

wtWebioAn1GraphAlarmMailText OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Alarm mail text: <Tn> provides the current temperature; n = 1..8.
        <Z> provides the current time."
    ::= { wtWebioAn1GraphAlarmEntry 10 }

wtWebioAn1GraphAlarmManagerIP OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Name or IP address of the SNMP Manager which accepts the trap."
    ::= { wtWebioAn1GraphAlarmEntry 11 }

wtWebioAn1GraphAlarmTrapText OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "This text is sent in the trap body."
    ::= { wtWebioAn1GraphAlarmEntry 12 }
    
wtWebioAn1GraphAlarmMailOptions OBJECT-TYPE
    SYNTAX OCTET STRING (SIZE(4))
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Binary coded options:
        Octet 1: unused
        Octet 2: unused
        Octet 3: unused
        Octet 4:
		Bit 0  :	Attach Thermo.csv Enable
        	Bit 1-7:	unused"
    ::= { wtWebioAn1GraphAlarmEntry 13 }    
    
wtWebioAn1GraphAlarmTcpIpAddr OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Name or IP address of the TCP server which accepts the trap."
    ::= { wtWebioAn1GraphAlarmEntry 14 }    

wtWebioAn1GraphAlarmTcpPort OBJECT-TYPE
    SYNTAX INTEGER (1..65535) 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Port number of the TCP server which accepts the trap."
    ::= { wtWebioAn1GraphAlarmEntry 15 }    

wtWebioAn1GraphAlarmTcpText OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "This text is sent in the TCP trap body."
    ::= { wtWebioAn1GraphAlarmEntry 16 }

wtWebioAn1GraphAlarmClearMailSubject OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Subject line for alarm clear mail."
    ::= { wtWebioAn1GraphAlarmEntry 17 }

wtWebioAn1GraphAlarmClearMailText OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        " Alarm clear mail text: <Tn> provides the current temperature; n = 1..8. <Z> provides the current time."
    ::= { wtWebioAn1GraphAlarmEntry 18 }

wtWebioAn1GraphAlarmClearTrapText OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "This text is sent in the trap body."
    ::= { wtWebioAn1GraphAlarmEntry 19 }

wtWebioAn1GraphAlarmClearTcpText OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "This text is sent in the TCP trap body."
    ::= { wtWebioAn1GraphAlarmEntry 20 }
    
wtWebioAn1GraphAlarmSyslogIpAddr OBJECT-TYPE
    SYNTAX IpAddress 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "IP address of the syslog server to which the Webio device should send syslog messages."
    ::= { wtWebioAn1GraphAlarmEntry 21 }    

wtWebioAn1GraphAlarmSyslogPort OBJECT-TYPE
    SYNTAX INTEGER (1..65535) 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Port number of the syslog server to which the Webio device should send syslog messages."
    ::= { wtWebioAn1GraphAlarmEntry 22 }    

wtWebioAn1GraphAlarmSyslogText OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
        This text appears in the following syslog message body."
    ::= { wtWebioAn1GraphAlarmEntry 23 }    
    
wtWebioAn1GraphAlarmSyslogClearText OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
        This text appears in the following syslog message body."
    ::= { wtWebioAn1GraphAlarmEntry 24 } 
    
wtWebioAn1GraphAlarmFtpDataPort OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Local data port: 1..65535 or AUTO: the next free port will be assigned."
    ::= { wtWebioAn1GraphAlarmEntry 25 }
    
wtWebioAn1GraphAlarmFtpFileName OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Name of the file including path informations."
    ::= { wtWebioAn1GraphAlarmEntry 26 }
    
wtWebioAn1GraphAlarmFtpText OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Message text to store on the FTP server."
    ::= { wtWebioAn1GraphAlarmEntry 27 }

wtWebioAn1GraphAlarmFtpClearText OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Alarm clear message to store on the FTP server."
    ::= { wtWebioAn1GraphAlarmEntry 28 }
    
wtWebioAn1GraphAlarmFtpOptions OBJECT-TYPE
    SYNTAX OCTET STRING (SIZE(4))
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Binary coded options, select only one option at the same time:
        STORE  = replace file
        APPEND = append message at the end of the file
        
        Octet 1: unused
        Octet 2: unused
        Octet 3: unused
        Octet 4:
		Bit 0  :	STORE
		Bit 1  :	APPEND
        	Bit 2-7:	unused"
    ::= { wtWebioAn1GraphAlarmEntry 29 }      
    
wtWebioAn1GraphAlarmTimerCron OBJECT-TYPE
    SYNTAX OCTET STRING
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "This entry contains 5 text fields space or tab seperated for time trigger definition.
        Each field must match with the actual time to trigger a message, weekday and day of month
        are interpreted separately.
        1: Minutes	Range 0-59
        2. Hours	Range 0-23, 0 is midnight
        3: Day of month	Range 1-31
        4: Month	Range 1-12
        5: Weekday	Range 0-6, 0 is sunday
        
        Syntax for every field:
         - an asterix (*) enables every possible setting of a field
         - single numbers seperated by commas
         - a partition within the allowed range (1-5)
         - step size within an partition of the allowed range (0-59/2: every second minute)."
    ::= { wtWebioAn1GraphAlarmEntry 30 }  

-- wtWebioAn1GraphPorts Group
----------------------------

-- Table

wtWebioAn1GraphPortTable OBJECT-TYPE
    SYNTAX SEQUENCE OF WtWebioAn1GraphPortEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "List of settings depending on the sensor number."
    ::= { wtWebioAn1GraphPorts 1 }

wtWebioAn1GraphPortEntry OBJECT-TYPE
    SYNTAX WtWebioAn1GraphPortEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "Sensor parameters for the individual sensors."
    INDEX  { wtWebioAn1GraphSensorNo }
    ::= { wtWebioAn1GraphPortTable 1 }

WtWebioAn1GraphPortEntry ::= SEQUENCE {
    wtWebioAn1GraphPortName		OCTET STRING,
    wtWebioAn1GraphPortText		OCTET STRING,
    wtWebioAn1GraphPortOffset1		OCTET STRING,
    wtWebioAn1GraphPortTemperature1	OCTET STRING,
    wtWebioAn1GraphPortOffset2		OCTET STRING,
    wtWebioAn1GraphPortTemperature2	OCTET STRING,
    wtWebioAn1GraphPortComment		OCTET STRING
    
}

wtWebioAn1GraphPortName OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Name of the sensor."
    ::= { wtWebioAn1GraphPortEntry 1 }

wtWebioAn1GraphPortText OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Description of the sensor."
    ::= { wtWebioAn1GraphPortEntry 2 }

wtWebioAn1GraphPortOffset1 OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1."
    ::= { wtWebioAn1GraphPortEntry 3 }

wtWebioAn1GraphPortTemperature1 OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places."
    ::= { wtWebioAn1GraphPortEntry 4 }

wtWebioAn1GraphPortOffset2 OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2."
    ::= { wtWebioAn1GraphPortEntry 5 }

wtWebioAn1GraphPortTemperature2 OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places."
    ::= { wtWebioAn1GraphPortEntry 6 }

wtWebioAn1GraphPortComment OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Offset calibration: informations of date, name of operator, reference devices."
    ::= { wtWebioAn1GraphPortEntry 7 }   
    
-- wtWebioAn1GraphManufact Group
----------------------------

wtWebioAn1GraphMfName OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Manufacturer company name"
    ::= { wtWebioAn1GraphManufact 1 }

wtWebioAn1GraphMfAddr OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Manufacturer address."
    ::= { wtWebioAn1GraphManufact 2 }

wtWebioAn1GraphMfHotline OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Manufacturer hotline."
    ::= { wtWebioAn1GraphManufact 3 }

wtWebioAn1GraphMfInternet OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Manufacturer Internet address."
    ::= { wtWebioAn1GraphManufact 4 }

wtWebioAn1GraphMfDeviceTyp OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Manufacturer device name (model number)."
    ::= { wtWebioAn1GraphManufact 5 }

wtWebioAn1GraphMfOrderNo OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Manufacturer part number."
    ::= { wtWebioAn1GraphManufact 6 }

-- wtWebioAn1GraphDiag Group
----------------------------

wtWebioAn1GraphDiagErrorCount OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Number of entries in the error memory."
    ::= { wtWebioAn1GraphDiag 1 }

wtWebioAn1GraphDiagBinaryError OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Error causes coded bit-by-bit."
    ::= { wtWebioAn1GraphDiag 2 }

wtWebioAn1GraphDiagErrorIndex OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "The value of this variable is used as an index to read 
        an error massege from wtWebioAn1GraphDiagErrorMessage.
        Errors are numbered from 1 to wtWebioAn1GraphDiagErrorCount.
        Writing a valid value into this variable, making the appropriate 
        message readable from wtWebioAn1GraphDiagErrorMessage."
    ::= { wtWebioAn1GraphDiag 3 }

wtWebioAn1GraphDiagErrorMessage OBJECT-TYPE
    SYNTAX OCTET STRING 
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Using wtWebioAn1GraphDiagErrorIndex as an index, the appropriate message is available."
    ::= { wtWebioAn1GraphDiag 4 }
    
wtWebioAn1GraphDiagErrorClear OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS write-only
    STATUS mandatory
    DESCRIPTION
        "Writing 1 into this variable clears all diagnosis messages."
    ::= { wtWebioAn1GraphDiag 5 }

-- TRAP DEFINITIONS

-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen 

wtWebioAn1GraphAlert1 TRAP-TYPE
    ENTERPRISE  wtWebioAn1Graph
    VARIABLES   { wtWebioAn1GraphAlarmTrapText }
    DESCRIPTION
        "This SNMP trap is generated when Alarm 1 was triggered,
        SNMP trap enable is set and
        SNMP is enabled."
    -- NMS trap annotation
    --#TYPE "Web-Thermograph Alarm 1"
    --#SUMMARY "Alarm 1: %s"
    --#ARGUMENTS {0}
    --#SEVERITY INFORMATIONAL
    --#TIMEINDEX 99
    --#STATE OPERATIONAL    
    ::= 31

wtWebioAn1GraphAlert2 TRAP-TYPE
    ENTERPRISE  wtWebioAn1Graph
    VARIABLES   { wtWebioAn1GraphAlarmTrapText }
    DESCRIPTION
        "This SNMP trap is generated when Alarm 2 was triggered,
        SNMP trap enable is set and
        SNMP is enabled."
    -- NMS trap annotation
    --#TYPE "Web-Thermograph Alarm 2"
    --#SUMMARY "Alarm 2: %s"
    --#ARGUMENTS {0}
    --#SEVERITY INFORMATIONAL
    --#TIMEINDEX 99
    --#STATE OPERATIONAL    
    ::= 32

wtWebioAn1GraphAlert3 TRAP-TYPE
    ENTERPRISE  wtWebioAn1Graph
    VARIABLES   { wtWebioAn1GraphAlarmTrapText }
    DESCRIPTION
        "This SNMP trap is generated when Alarm 3 was triggered,
        SNMP trap enable is set and
        SNMP is enabled."
    -- NMS trap annotation
    --#TYPE "Web-Thermograph Alarm 3"
    --#SUMMARY "Alarm 3: %s"
    --#ARGUMENTS {0}
    --#SEVERITY INFORMATIONAL
    --#TIMEINDEX 99
    --#STATE OPERATIONAL    
    ::= 33

wtWebioAn1GraphAlert4 TRAP-TYPE
    ENTERPRISE  wtWebioAn1Graph
    VARIABLES   { wtWebioAn1GraphAlarmTrapText }
    DESCRIPTION
        "This SNMP trap is generated when Alarm 4 was triggered,
        SNMP trap enable is set and
        SNMP is enabled."
    -- NMS trap annotation
    --#TYPE "Web-Thermograph Alarm 4"
    --#SUMMARY "Alarm 4: %s"
    --#ARGUMENTS {0}
    --#SEVERITY INFORMATIONAL
    --#TIMEINDEX 99
    --#STATE OPERATIONAL    
    ::= 34

wtWebioAn1GraphAlert5 TRAP-TYPE
    ENTERPRISE  wtWebioAn1Graph
    VARIABLES   { wtWebioAn1GraphAlarmTrapText }
    DESCRIPTION
        "This SNMP trap is generated when Alarm 5 was triggered,
        SNMP trap enable is set and
        SNMP is enabled."
    -- NMS trap annotation
    --#TYPE "Web-Thermograph Alarm 5"
    --#SUMMARY "Alarm 5: %s"
    --#ARGUMENTS {0}
    --#SEVERITY INFORMATIONAL
    --#TIMEINDEX 99
    --#STATE OPERATIONAL    
    ::= 35

wtWebioAn1GraphAlert6 TRAP-TYPE
    ENTERPRISE  wtWebioAn1Graph
    VARIABLES   { wtWebioAn1GraphAlarmTrapText }
    DESCRIPTION
        "This SNMP trap is generated when Alarm 6 was triggered,
        SNMP trap enable is set and
        SNMP is enabled."
    -- NMS trap annotation
    --#TYPE "Web-Thermograph Alarm 6"
    --#SUMMARY "Alarm 6: %s"
    --#ARGUMENTS {0}
    --#SEVERITY INFORMATIONAL
    --#TIMEINDEX 99
    --#STATE OPERATIONAL    
    ::= 36

wtWebioAn1GraphAlert7 TRAP-TYPE
    ENTERPRISE  wtWebioAn1Graph
    VARIABLES   { wtWebioAn1GraphAlarmTrapText }
    DESCRIPTION
        "This SNMP trap is generated when Alarm 7 was triggered,
        SNMP trap enable is set and
        SNMP is enabled."
    -- NMS trap annotation
    --#TYPE "Web-Thermograph Alarm 7"
    --#SUMMARY "Alarm 7: %s"
    --#ARGUMENTS {0}
    --#SEVERITY INFORMATIONAL
    --#TIMEINDEX 99
    --#STATE OPERATIONAL    
    ::= 37

wtWebioAn1GraphAlert8 TRAP-TYPE
    ENTERPRISE  wtWebioAn1Graph
    VARIABLES   { wtWebioAn1GraphAlarmTrapText }
    DESCRIPTION
        "This SNMP trap is generated when Alarm 8 was triggered,
        SNMP trap enable is set and
        SNMP is enabled."
    -- NMS trap annotation
    --#TYPE "Web-Thermograph Alarm 8"
    --#SUMMARY "Alarm 8: %s"
    --#ARGUMENTS {0}
    --#SEVERITY INFORMATIONAL
    --#TIMEINDEX 99
    --#STATE OPERATIONAL    
    ::= 38

    
wtWebioAn1GraphAlert9 TRAP-TYPE
    ENTERPRISE  wtWebioAn1Graph
    VARIABLES   { wtWebioAn1GraphAlarmClearTrapText }
    DESCRIPTION
        "This SNMP trap is generated when Alarm 1 was cleared,
        SNMP trap enable is set and
        SNMP is enabled."
    -- NMS trap annotation
    --#TYPE "Web-Thermograph Release Alarm 1"
    --#SUMMARY "Release Alarm 1: %s"
    --#ARGUMENTS {0}
    --#SEVERITY INFORMATIONAL
    --#TIMEINDEX 99
    --#STATE OPERATIONAL    
    ::= 91

wtWebioAn1GraphAlert10 TRAP-TYPE
    ENTERPRISE  wtWebioAn1Graph
    VARIABLES   { wtWebioAn1GraphAlarmClearTrapText }
    DESCRIPTION
        "This SNMP trap is generated when Alarm 2 was cleared,
        SNMP trap enable is set and
        SNMP is enabled."
    -- NMS trap annotation
    --#TYPE "Web-Thermograph Release Alarm 2"
    --#SUMMARY "Release Alarm 2: %s"
    --#ARGUMENTS {0}
    --#SEVERITY INFORMATIONAL
    --#TIMEINDEX 99
    --#STATE OPERATIONAL    
    ::= 92

wtWebioAn1GraphAlert11 TRAP-TYPE
    ENTERPRISE  wtWebioAn1Graph
    VARIABLES   { wtWebioAn1GraphAlarmClearTrapText }
    DESCRIPTION
        "This SNMP trap is generated when Alarm 3 was cleared,
        SNMP trap enable is set and
        SNMP is enabled."
    -- NMS trap annotation
    --#TYPE "Web-Thermograph Release Alarm 3"
    --#SUMMARY "Release Alarm 3: %s"
    --#ARGUMENTS {0}
    --#SEVERITY INFORMATIONAL
    --#TIMEINDEX 99
    --#STATE OPERATIONAL    
    ::= 93

wtWebioAn1GraphAlert12 TRAP-TYPE
    ENTERPRISE  wtWebioAn1Graph
    VARIABLES   { wtWebioAn1GraphAlarmClearTrapText }
    DESCRIPTION
        "This SNMP trap is generated when Alarm 4 was cleared,
        SNMP trap enable is set and
        SNMP is enabled."
    -- NMS trap annotation
    --#TYPE "Web-Thermograph Release Alarm 4"
    --#SUMMARY "Release Alarm 4: %s"
    --#ARGUMENTS {0}
    --#SEVERITY INFORMATIONAL
    --#TIMEINDEX 99
    --#STATE OPERATIONAL    
    ::= 94

wtWebioAn1GraphAlert13 TRAP-TYPE
    ENTERPRISE  wtWebioAn1Graph
    VARIABLES   { wtWebioAn1GraphAlarmClearTrapText }
    DESCRIPTION
        "This SNMP trap is generated when Alarm 5 was cleared,
        SNMP trap enable is set and
        SNMP is enabled."
    -- NMS trap annotation
    --#TYPE "Web-Thermograph Release Alarm 5"
    --#SUMMARY "Release Alarm 5: %s"
    --#ARGUMENTS {0}
    --#SEVERITY INFORMATIONAL
    --#TIMEINDEX 99
    --#STATE OPERATIONAL    
    ::= 95

wtWebioAn1GraphAlert14 TRAP-TYPE
    ENTERPRISE  wtWebioAn1Graph
    VARIABLES   { wtWebioAn1GraphAlarmClearTrapText }
    DESCRIPTION
        "This SNMP trap is generated when Alarm 6 was cleared,
        SNMP trap enable is set and
        SNMP is enabled."
    -- NMS trap annotation
    --#TYPE "Web-Thermograph Release Alarm 6"
    --#SUMMARY "Release Alarm 6: %s"
    --#ARGUMENTS {0}
    --#SEVERITY INFORMATIONAL
    --#TIMEINDEX 99
    --#STATE OPERATIONAL    
    ::= 96

wtWebioAn1GraphAlert15 TRAP-TYPE
    ENTERPRISE  wtWebioAn1Graph
    VARIABLES   { wtWebioAn1GraphAlarmClearTrapText }
    DESCRIPTION
        "This SNMP trap is generated when Alarm 7 was cleared,
        SNMP trap enable is set and
        SNMP is enabled."
    -- NMS trap annotation
    --#TYPE "Web-Thermograph Release Alarm 7"
    --#SUMMARY "Release Alarm 7: %s"
    --#ARGUMENTS {0}
    --#SEVERITY INFORMATIONAL
    --#TIMEINDEX 99
    --#STATE OPERATIONAL    
    ::= 97

wtWebioAn1GraphAlert16 TRAP-TYPE
    ENTERPRISE  wtWebioAn1Graph
    VARIABLES   { wtWebioAn1GraphAlarmClearTrapText }
    DESCRIPTION
        "This SNMP trap is generated when Alarm 8 was cleared,
        SNMP trap enable is set and
        SNMP is enabled."
    -- NMS trap annotation
    --#TYPE "Web-Thermograph Release Alarm 8"
    --#SUMMARY "Release Alarm 8: %s"
    --#ARGUMENTS {0}
    --#SEVERITY INFORMATIONAL
    --#TIMEINDEX 99
    --#STATE OPERATIONAL    
    ::= 98

wtWebioAn1GraphAlertDiag TRAP-TYPE
    ENTERPRISE  wtWebioAn1Graph
    VARIABLES   { 	
    		wtWebioAn1GraphDiagErrorIndex,
    	  	wtWebioAn1GraphDiagErrorMessage
    		}
    DESCRIPTION
        "This SNMP trap is generated when a diagnosis/error message was triggered,
        SNMP trap enable is set and
        SNMP is enabled."
    -- NMS trap annotation
    --#TYPE "Web-Thermograph Diagnose Error"
    --#SUMMARY "Diagnose error index: %d, Message: %s."
    --#ARGUMENTS {0,1}
    --#SEVERITY MAJOR
    --#TIMEINDEX 99
    --#STATE DEGRADED    
    ::= 110 

END