PKTC-SIG-MIB DEFINITIONS ::= BEGIN

IMPORTS
      MODULE-IDENTITY,
      OBJECT-TYPE,
      Integer32,
      IpAddress
            FROM SNMPv2-SMI
      TEXTUAL-CONVENTION,
      RowStatus,
      TruthValue
            FROM SNMPv2-TC
      OBJECT-GROUP,
      MODULE-COMPLIANCE
            FROM SNMPv2-CONF
      SnmpAdminString
            FROM SNMP-FRAMEWORK-MIB
      clabProjPacketCable
            FROM CLAB-DEF-MIB
      ifIndex 
            FROM IF-MIB;

pktcSigMib  MODULE-IDENTITY
      LAST-UPDATED    "200501280000Z" -- January 28, 2005
      ORGANIZATION    "CableLabs -- PacketCable OSS Group"
      CONTACT-INFO
            "Sumanth Channabasappa
            Postal:  CableLabs, Inc.
                     858 Coal Creek Circle
                     Louisville, CO 80027-9750
                     U.S.A.
            Phone:  +1 303-661-9100
            Fax:    +1 303-661-9199
            E-mail: mibs@cablelabs.com"
    DESCRIPTION
            "This MIB module supplies the basic management 
            object for the PacketCable Signaling 
            protocols. This version of the MIB includes
            common signaling and Network Call Signaling
            (NCS) related signaling objects.
            Acknowledgements:
            Angela Lyda       Arris Interactive
            Sasha Medvinsky   Motorola
            Roy Spitzer       Telogy Networks, Inc.
            Rick Vetter       Motorola
            Itay Sherman      Texas Instruments
            Klaus Hermanns    Cisco Systems
            Eugene Nechamkin  Broadcom Corp.
            Satish Kumar      Texas Instruments
            Copyright 1999-2005 Cable Television Laboratories, Inc.
            All rights reserved."
      REVISION "200501280000Z"
      DESCRIPTION
            "This revision, published as part of the PacketCable
            1.5 Signaling MIB I01 Specification."
      ::=  { clabProjPacketCable 2 }

PktcCodecType     ::= TEXTUAL-CONVENTION
      STATUS       current
      DESCRIPTION 
            "Textual Convention defines various types of 
            CODECs that MAY be supported.   The list of CODECs 
            MUST be consistent with the Codec RTP MAP Parameters
            Table in the PacketCable CODEC specification.  In-line 
            embedded comments below contain the Literal Codec Name  
            for each CODEC. The Literal Codec Name corresponds to 
            the second column of the Codec RTP MAP Parameters Table. 
            The Literal Codec Name Column contains the CODEC name 
            that is used in the LCD of the NCS messages CRCX/MDCX, 
            and is also used to identify the CODEC in the CMS 
            Provisioning Specification. The RTP Map Parameter 
            Column of the Codec RTP MAP Parameters Table contains
            the string used in the media attribute line ('a=') of the 
            SDP parameters in NCS messages."
      REFERENCE 
            "PacketCable CODEC Specification"
      SYNTAX INTEGER {
            other    (1),
            unknown  (2),
            g729     (3),  -- G729
            reserved (4),  -- reserved for future use
            g729E    (5),  -- G729E 
            pcmu     (6),  -- PCMU
            g726at32 (7),  -- G726-32
            g728     (8),  -- G728
            pcma     (9),  -- PCMA
            g726at16 (10), -- G726-16
            g726at24 (11), -- G726-24
            g726at40 (12), -- G726-40
            ilbc     (13), -- iLBC
            bv16     (14)  -- BV16
            }

PktcRingCadence    ::= TEXTUAL-CONVENTION
      STATUS        current
      DESCRIPTION   
            "This object represents a ring cadence in bit string 
            format. The ring cadence representation starts with the 
            first 1 in the pattern (the leading 0s in the MSB are 
            padding and are to be ignored).  Each bit 
            represents 100ms of tone; 1 is tone, 0 is no tone. 64
            bits MUST be used for cadence representation, LSB 4 bits
            are used for representing repeatable characteristics. 
            0000 means repeatable, and 1000 means non repeatable. 
            During SNMP SET operations 64 bits MUST be used, 
            otherwise MTA MUST reject the value. As an example, the 
            hex representation of a ring cadence of 0.5 secs on; 4 
            secs off; repeatable would be:0x0001F00000000000."
      SYNTAX  BITS {
            interval1 (0),
            interval2 (1),
            interval3 (2),
            interval4 (3),
            interval5 (4),
            interval6 (5),
            interval7 (6),
            interval8 (7),
            interval9 (8),
            interval10 (9),
            interval11 (10),
            interval12 (11),
            interval13 (12),
            interval14 (13),
            interval15 (14),
            interval16 (15),
            interval17 (16),
            interval18 (17),
            interval19 (18),
            interval20 (19),
            interval21 (20),
            interval22 (21),
            interval23 (22),
            interval24 (23),
            interval25 (24),
            interval26 (25),
            interval27 (26),
            interval28 (27),
            interval29 (28),
            interval30 (29),
            interval31 (30),
            interval32 (31),
            interval33 (32),
            interval34 (33),
            interval35 (34),
            interval36 (35),
            interval37 (36),
            interval38 (37),
            interval39 (38),
            interval40 (39),
            interval41 (40),
            interval42 (41),
            interval43 (42),
            interval44 (43),
            interval45 (44),
            interval46 (45),
            interval47 (46),
            interval48 (47),
            interval49 (48),
            interval50 (49),
            interval51 (50),
            interval52 (51),
            interval53 (52),
            interval54 (53),
            interval55 (54),
            interval56 (55),
            interval57 (56),
            interval58 (57),
            interval59 (58),
            interval60 (59),
            interval61 (60),
            interval62 (61),
            interval63 (62),
            interval64 (63)
      }


PktcSigType     ::= TEXTUAL-CONVENTION
      STATUS       current
      DESCRIPTION  
            "These are the various types of signaling that 
            may be supported. 
            ncs - network call signaling a derivation of MGCP
            (Media Gateway Control Protocol) version 1.0
            dcs - distributed call signaling a derivation
            of SIP (Session Initiation Protocol) RFC 3261"
      SYNTAX INTEGER {
            other(1),
            unknown(2),
            ncs(3),
            dcs(4)
    }

pktcSigMibObjects            OBJECT IDENTIFIER 
                                            ::= { pktcSigMib 1 }
pktcSigDevConfigObjects      OBJECT IDENTIFIER 
                                            ::= { pktcSigMibObjects 1 }
pktcNcsEndPntConfigObjects   OBJECT IDENTIFIER 
                                            ::= { pktcSigMibObjects 2 }
pktcSigEndPntConfigObjects  OBJECT IDENTIFIER 
                                            ::= { pktcSigMibObjects 3 }
pktcDcsEndPntConfigObjects  OBJECT IDENTIFIER 
                                            ::= { pktcSigMibObjects 4 }

--
--      The pktcSigDevCodecTable defines the codecs supported by this
--      Media Terminal Adapter (MTA).  There is one entry for each 
--      codecs supported.
--

pktcSigDevCodecTable    OBJECT-TYPE 
      SYNTAX      SEQUENCE OF PktcSigDevCodecEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
            "This table describes the MTA supported codec types."
      ::= { pktcSigDevConfigObjects 1 }

pktcSigDevCodecEntry  OBJECT-TYPE
      SYNTAX      PktcSigDevCodecEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
            "List of supported codecs types for the MTA."
      INDEX { pktcSigDevCodecIndex }
      ::= { pktcSigDevCodecTable 1 }

PktcSigDevCodecEntry  ::= SEQUENCE {
      pktcSigDevCodecIndex  Integer32,
      pktcSigDevCodecType   PktcCodecType,
      pktcSigDevCodecMax    Integer32
      }

pktcSigDevCodecIndex  OBJECT-TYPE
      SYNTAX      Integer32 (1..16383)
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
            "The index value which uniquely identifies an entry
            in the pktcSigDevCodecTable."
    ::= { pktcSigDevCodecEntry 1 }


pktcSigDevCodecType  OBJECT-TYPE
      SYNTAX       PktcCodecType
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION
            "A codec type supported by this MTA."
      ::= { pktcSigDevCodecEntry 2 }

pktcSigDevCodecMax  OBJECT-TYPE
      SYNTAX    Integer32(1..16383)
      MAX-ACCESS  read-only
      STATUS   current
      DESCRIPTION
            "The maximum number of simultaneous sessions of the 
            specific codec that the MTA can support"
    ::= { pktcSigDevCodecEntry 3 }


--
--    These are the common signaling related definitions that affect 
--    the entire MTA device.
--


pktcSigDevEchoCancellation  OBJECT-TYPE
      SYNTAX       TruthValue
      MAX-ACCESS       read-only
      STATUS         current
      DESCRIPTION
            "This object specifies if the device is capable 
            of echo cancellation."
    ::= { pktcSigDevConfigObjects 2 }

pktcSigDevSilenceSuppression  OBJECT-TYPE
      SYNTAX       TruthValue
      MAX-ACCESS       read-only
      STATUS       current
      DESCRIPTION
            "This object specifies if the device is capable of 
             silence suppression (Voice Activity Detection)."
    ::= { pktcSigDevConfigObjects 3 }

pktcSigDevConnectionMode     OBJECT-TYPE
      SYNTAX BITS {
            voice(0), 
            fax(1), 
            modem(2)
    }
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION
            "This object specifies the connection modes that the 
             MTA device can support."
    ::= { pktcSigDevConfigObjects 4 }

--
--      In the United States Ring Cadences 0, 6, and 7 are custom
--      ring cadences definable by the user.  The following three
--      objects are used for these definitions.
--

pktcSigDevR0Cadence     OBJECT-TYPE
      SYNTAX    PktcRingCadence
      MAX-ACCESS       read-write
      STATUS       current
      DESCRIPTION
            "This object specifies ring cadence 0 (a user defined 
            field) where each bit (least significant bit) 
            represents a duration of 200 milliseconds (6 seconds 
            total)."
      DEFVAL {{ interval1, interval2, interval3, interval4, interval5,
      interval6, interval7, interval8,  interval9, interval10, 
      interval11, interval12, interval13, interval14, interval15, 
      interval16, interval17, interval18, interval19, interval20}} 
      -- '11111111111111111111000000000000000000000000000000000000000
      -- 00000'
      ::= { pktcSigDevConfigObjects 5 }


pktcSigDevR6Cadence     OBJECT-TYPE
      SYNTAX    PktcRingCadence
      MAX-ACCESS       read-write
      STATUS       current
      DESCRIPTION
            "This object specifies ring cadence 6 (a user defined 
            field) where each bit (least significant bit) 
            represents a duration of 200 milliseconds (6 seconds 
            total)."
      DEFVAL { { interval1, interval2, interval3, interval4, 
      interval5, interval6, interval7, interval8, interval9, 
      interval10, interval11, interval12, interval13, interval14, 
      interval15, interval16, interval17, interval18, interval19, 
      interval20 } }
      -- '11111111111111111111000000000000000000000000000000000000000
      -- 00000'
      ::= { pktcSigDevConfigObjects 6 }

pktcSigDevR7Cadence     OBJECT-TYPE
      SYNTAX    PktcRingCadence
      MAX-ACCESS       read-write
      STATUS       current
      DESCRIPTION
            "This object specifies ring cadence 7 (a user defined 
            field) where each bit (least significant bit) 
            represents a duration of 200 milliseconds (6 seconds 
            total)."
 
      DEFVAL { { interval1, interval2, interval3, interval4, 
      interval5, interval6, interval7, interval8, interval9, 
      interval10, interval11, interval12, interval13, interval14, 
      interval15, interval16, interval17, interval18, interval19, 
      interval20 } }
      -- '11111111111111111111000000000000000000000000000000000000000
      -- 00000'
      ::= { pktcSigDevConfigObjects 7 }


pktcSigDefCallSigTos  OBJECT-TYPE
      SYNTAX      Integer32 (0..63)    
      MAX-ACCESS    read-write    
      STATUS    current    
      DESCRIPTION
            "The default value used in the IP header for setting the 
            Type of Service (TOS) value for call signalling."
      REFERENCE
            "Refer to NCS specification"    DEFVAL { 0 }
      ::= { pktcSigDevConfigObjects 8 }

pktcSigDefMediaStreamTos  OBJECT-TYPE
      SYNTAX      Integer32 (0..63)
      MAX-ACCESS    read-write
      STATUS    current
      DESCRIPTION

            "This object contains the default value used in the IP 
            header for setting the Type of Service (TOS) for media
            stream packets. The MTA MUST NOT update this object with
            the value supplied by the CMS in the NCS messages (if 
            present).  When the value of this object is updated by 
            SNMP, the MTA MUST use the new value as a default starting
            from the new connection.  Existing connections are not
            affected by the value's update."      REFERENCE
            "Refer to NCS specification"
      DEFVAL { 0 }
      ::= { pktcSigDevConfigObjects 9 }

pktcSigTosFormatSelector  OBJECT-TYPE
      SYNTAX      INTEGER { 
            ipv4TOSOctet(1),
            dscpCodepoint(2)
      }          
      MAX-ACCESS    read-write
      STATUS    current
      DESCRIPTION
            "The format of the default signaling and media 
            Type of Service (TOS) values."
      DEFVAL { ipv4TOSOctet }
      ::= { pktcSigDevConfigObjects 10 }

--
--      pktcSigCapabilityTable - This table defines the valid signaling
--      types supported by this MTA.
--

pktcSigCapabilityTable    OBJECT-TYPE
      SYNTAX        SEQUENCE OF PktcSigCapabilityEntry
      MAX-ACCESS    not-accessible
      STATUS        current
      DESCRIPTION   
            "This table describes the signaling types by this MTA."
      ::= { pktcSigDevConfigObjects 11 }

pktcSigCapabilityEntry    OBJECT-TYPE
      SYNTAX        PktcSigCapabilityEntry   
      MAX-ACCESS    not-accessible
      STATUS        current
      DESCRIPTION   
            "Entries in pktcMtaDevSigCapabilityTable - List of 
            supported signaling types, versions and vendor extensions 
            for this MTA. Each entry in the list provides for one 
            signaling type and version combination. If the device 
            supports multiple versions of the same signaling type - 
            it will require multiple entries."
      INDEX { pktcSignalingIndex }
      ::= { pktcSigCapabilityTable 1 }

PktcSigCapabilityEntry  ::= SEQUENCE {
      pktcSignalingIndex             Integer32,
      pktcSignalingType              PktcSigType,
      pktcSignalingVersion           SnmpAdminString,
      pktcSignalingVendorExtension   SnmpAdminString
      }

pktcSignalingIndex       OBJECT-TYPE
      SYNTAX        Integer32 (1..16383)
      MAX-ACCESS    not-accessible
      STATUS        current
      DESCRIPTION   
            "The index value which uniquely identifies 
            an entry in the pktcSigCapabilityTable." 
      ::= { pktcSigCapabilityEntry 1 }

pktcSignalingType      OBJECT-TYPE
      SYNTAX        PktcSigType
      MAX-ACCESS    read-only
      STATUS        current
      DESCRIPTION   
            "The Type identifies the type of signaling 
            used, this can be NCS, DCS, etc. This value
            has to be associated with a single signaling 
            version - reference pktcMtaDevSignalingVersion."
    ::= { pktcSigCapabilityEntry 2 }

pktcSignalingVersion      OBJECT-TYPE
      SYNTAX        SnmpAdminString
      MAX-ACCESS    read-only
      STATUS        current
      DESCRIPTION   
            "Provides the version of the signaling type -
            reference pktcSignalingType. Examples
            would be 1.0 or 2.33 etc."
    ::= { pktcSigCapabilityEntry 3 }

pktcSignalingVendorExtension      OBJECT-TYPE
      SYNTAX        SnmpAdminString
      MAX-ACCESS    read-only
      STATUS        current
      DESCRIPTION  
            "The vendor extension allows vendors to 
            provide a list of additional capabilities,
            vendors can decide how to encode these
            Extensions, although space separated text is
            suggested."
    ::= { pktcSigCapabilityEntry 4 }

pktcSigDefNcsReceiveUdpPort  OBJECT-TYPE
      SYNTAX      Integer32 (1025..65535)
      MAX-ACCESS    read-write
      STATUS    current
      DESCRIPTION
            "This object contains the MTA User Datagram Protocol
            (UDP) receive port that is being used for NCS call 
            signaling. This object should only be changed by the 
            configuration file."
      REFERENCE
            "Refer to NCS specification"
      DEFVAL { 2427 }
      ::= { pktcSigDevConfigObjects 12 }

pktcSigServiceClassNameUS   OBJECT-TYPE
      SYNTAX    SnmpAdminString (SIZE (0..15)) 
      MAX-ACCESS   read-write
      STATUS       obsolete
      DESCRIPTION
            "This object contains a string indicating the Service 
            Class name to create an Upstream Service (US) Flow for 
            NCS. If the object has an empty string value then the 
            upstream NCS SF is not created and the best effort 
            SF is used for upstream NCS data. The creation of the NCS 
            SF primary occurs before Voice Communication Service is 
            activated on the device. If this object is set to a 
            non-empty (non-zero length) string, the MTA MUST create 
            the NCS SF if it does not currently exist and the 
            pktcSigServiceClassNameMask object has a non-zero value. 
            If this object is subsequently set to an empty 
            (zero-length)string , the MTA MUST delete the NCS SF 
            if it exists.  Setting this object to a different value 
            does not cause the Upstream Service Flow to be 
            re-created. The string MUST contain printable ASCII
            characters. The length of the string does not include a 
            terminating zero.  The MTA MUST append a terminating zero
            when the MTA creates the service flow. " 
      ::= { pktcSigDevConfigObjects 13 }

pktcSigServiceClassNameDS   OBJECT-TYPE
      SYNTAX     SnmpAdminString (SIZE (0..15)) 
      MAX-ACCESS   read-write
      STATUS       obsolete
      DESCRIPTION
            "This object contains a string indicating the Service 
           Class Name to create a Downstream Service Flow for NCS. 
            If the object has an empty string value then the 
            NCS SF is not created and the best effort primary SF is 
            used for downstream NCS data. The creation of the NCS SF 
            occurs before Voice Communication Service is activated on 
            the device. If this object is set to a non-empty (non-zero 
            length) string, the MTA MUST create the NCS SF if it does 
            not currently exist and the pktcSigServiceClassNameMask 
            object has a non-zero value.  If this object is 
            subsequently set to an empty (zero-length) string, the MTA 
            MUST delete the NCS SF if it exists.  Setting this object 
            to a different value does not cause the Downstream Service 
            Flow to be re-created.  The string MUST contain printable 
            ASCII characters. The length of the string does not include 
            a terminating zero.  The MTA MUST append a terminating 
            zero when the MTA creates the service flow. "
      ::= { pktcSigDevConfigObjects 14 }

pktcSigServiceClassNameMask   OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS read-write
      STATUS     obsolete
      DESCRIPTION
            "This object contains a value for the Call Signaling 
            Network Mask. The value is used as the NCS Call Signaling 
            classifier mask. The object is used to delete the NCS SF 
            when set to zero. When the object is set to a non-zero 
            value by the SNMP Manager, the NCS SF are to be created."
      DEFVAL { 0 }
      ::= { pktcSigDevConfigObjects 15 }

pktcSigNcsServiceFlowState  OBJECT-TYPE
      SYNTAX      INTEGER {
            notactive  (1),
            active     (2),
            error      (3)
      }
      MAX-ACCESS read-only
      STATUS     obsolete
      DESCRIPTION
            "This object contains a status value of the Call Signaling 
            Service Flow. 
            - 'notactive' indicates that the NCS SF is not being used,
            and has not tried to be created, 
            - 'active' indicates that the NCS SF is in use, 
            - 'error' indicates that the NCS SF creation resulted in 
            an error and the best effort channel is used for NCS 
            Signaling."
      ::= { pktcSigDevConfigObjects 16 }

pktcSigDevR1Cadence       OBJECT-TYPE
      SYNTAX    PktcRingCadence
      MAX-ACCESS       read-write
      STATUS       current
      DESCRIPTION
            "This object specifies ring cadence 1 (a user defined 
            field) where each bit (least significant bit) 
            represents a duration of 100 milliseconds (6 seconds
            total)."

      DEFVAL { { interval1, interval2, interval3, interval4, 
      interval5, interval6, interval7, interval8, interval9, 
      interval10, interval11, interval12, interval13, interval14, 
      interval15, interval16, interval17, interval18, interval19, 
      interval20 } }
      -- '11111111111111111111000000000000000000000000000000000000000
      -- 00000'
      ::= { pktcSigDevConfigObjects 17 }

pktcSigDevR2Cadence       OBJECT-TYPE
      SYNTAX    PktcRingCadence
      MAX-ACCESS       read-write
      STATUS       current
      DESCRIPTION
            "This object specifies ring cadence 2 (a user
            defined field) where each bit (least significant
            bit) represents a duration of 100 milliseconds
            (6 seconds total)."
 
      DEFVAL { { interval1, interval2, interval3, interval4, 
      interval5, interval6, interval7, interval8, interval13, 
      interval14, interval15, interval16, interval17, interval18, 
      interval19, interval20 } }
      -- '11111111000011111111000000000000000000000000000000000000000
      -- 00000'
      ::= { pktcSigDevConfigObjects 18 }

pktcSigDevR3Cadence       OBJECT-TYPE
      SYNTAX    PktcRingCadence
      MAX-ACCESS       read-write
      STATUS       current
      DESCRIPTION
        "This object specifies ring cadence 3 (a user
        defined field) where each bit (least significant
        bit) represents a duration of 100 milliseconds
       (6 seconds total)."
 
      DEFVAL { { interval1, interval2, interval3, interval4, 
      interval7, interval8, interval9, interval10, interval13, 
      interval14, interval15, interval16, interval17, interval18, 
      interval19, interval20 } }
      -- '11110011110011111111000000000000000000000000000000000000000
      -- 00000'
    ::= { pktcSigDevConfigObjects 19 }

pktcSigDevR4Cadence        OBJECT-TYPE
      SYNTAX    PktcRingCadence
      MAX-ACCESS       read-write
      STATUS       current
      DESCRIPTION
            "This object specifies ring cadence 4 (a user
            defined field) where each bit (least significant
            bit) represents a duration of 100 milliseconds
            (6 seconds total)."
      DEFVAL { { interval1, interval2, interval3, interval6, 
      interval7, interval8, interval9, interval10, interval11, 
      interval12, interval13, interval14, interval15, interval18, 
      interval19, interval20 } }
      -- '11100111111111100111000000000000000000000000000000000000000
      -- 00000'
    ::= { pktcSigDevConfigObjects 20 }

pktcSigDevR5Cadence       OBJECT-TYPE
      SYNTAX    PktcRingCadence
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION
            "This object specifies ring cadence 5 (a user
            defined field) where each bit (least significant
            bit) represents a duration of 100 milliseconds."
      DEFVAL { { interval1, interval2, interval3, interval4, 
      interval5, interval61 } }
      -- '11111000000000000000000000000000000000000000000000000000000
      -- 01000'
      ::= { pktcSigDevConfigObjects 21 }

pktcSigDevRgCadence       OBJECT-TYPE
      SYNTAX    PktcRingCadence
      MAX-ACCESS       read-write
      STATUS       current
      DESCRIPTION
            "This object specifies ring cadence rg (a user
            defined field) where each bit (least significant
            bit) represents a duration of 100 milliseconds
           (6 seconds total)."

      DEFVAL { { interval1, interval2, interval3, interval4, 
      interval5, interval6, interval7, interval8, interval9, 
      interval10, interval11, interval12, interval13, interval14, 
      interval15, interval16, interval17, interval18, interval19, 
      interval20 } }
      -- '11111111111111111111000000000000000000000000000000000000000
      -- 00000'
    ::= { pktcSigDevConfigObjects 22 }

pktcSigDevRsCadence       OBJECT-TYPE
      SYNTAX       PktcRingCadence
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION
            "This object specifies ring cadence rs (a user 
            defined field) where each bit (least significant bit)
            represents a duration of 100 milliseconds (6 seconds 
            total). MTA MUST reject any attempt to make this 
            object repeatable."
      DEFVAL { { interval1, interval2, interval3, interval4, 
      interval5, interval61 } }
      -- '11111000000000000000000000000000000000000000000000000000000
      -- 01000'
    ::= { pktcSigDevConfigObjects 23 }

pktcSigDevRtCadence       OBJECT-TYPE
      SYNTAX    PktcRingCadence
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION
            "This object specifies ring cadence rt (a user
            defined field) where each bit (least significant
            bit) represents a duration of 100 milliseconds
           (6 seconds total)."
      DEFVAL { { interval1, interval2, interval3, interval4, 
      interval5, interval6, interval7, interval8, interval9, 
      interval10, interval11, interval12, interval13, interval14, 
      interval15, interval16, interval17, interval18, interval19, 
      interval20 } }
      -- '11111111111111111111000000000000000000000000000000000000000
      -- 00000'
    ::= { pktcSigDevConfigObjects 24 }

--
-- The following Table will provide endpoint configuration
-- information that is common to all signaling Protocols.
-- Currently only the signaling index is present in an effort
-- not to deprecate any MIB objects.
--

pktcSigEndPntConfigTable    OBJECT-TYPE
      SYNTAX        SEQUENCE OF PktcSigEndPntConfigEntry
      MAX-ACCESS    not-accessible
      STATUS        current
      DESCRIPTION   
            "This table describes the PacketCable EndPoint selected
            signaling type. The number of entries in this table 
            represents the number of provisioned end points.
            For each conceptual row of pktcSigEndPntConfigTable 
            defined, an associated row MUST be defined in one of 
            the specific signaling tables such as 
            pktcNcsEndPntConfigTable."
     ::=  { pktcSigEndPntConfigObjects 1 }

pktcSigEndPntConfigEntry    OBJECT-TYPE
      SYNTAX        PktcSigEndPntConfigEntry
      MAX-ACCESS    not-accessible
      STATUS        current
      DESCRIPTION   
            "Entries in pktcSigEndPntConfigTable - Each entry 
            describes what signaling type a particular endpoint uses."
      INDEX { ifIndex }
      ::=  { pktcSigEndPntConfigTable 1 }

PktcSigEndPntConfigEntry  ::= SEQUENCE {
            pktcSigEndPntCapabilityIndex           Integer32 
      }


pktcSigEndPntCapabilityIndex    OBJECT-TYPE
      SYNTAX        Integer32 (1..16383)  
      MAX-ACCESS    read-create
      STATUS        current
      DESCRIPTION   
            "The associated index value in the pktcSigCapablityTable."
      ::= { pktcSigEndPntConfigEntry 1 }
--
--    The NCS End Point Config Table is used to define attributes that 
--    are specific to connection EndPoints.
--
--

pktcNcsEndPntConfigTable  OBJECT-TYPE
      SYNTAX        SEQUENCE OF PktcNcsEndPntConfigEntry
      MAX-ACCESS    not-accessible
      STATUS        current
      DESCRIPTION   
            "This table describes the PacketCable EndPoint selected 
             signaling type. The number of entries in this table 
             represents the number of provisioned end points.
             For each conceptual row of pktcSigEndPntConfigTable 
             defined, an associated row MUST be defined in one of 
             the specific signaling tables such as 
             pktcNcsEndPntConfigTable."
      ::=  { pktcNcsEndPntConfigObjects 1 }

pktcNcsEndPntConfigEntry  OBJECT-TYPE
      SYNTAX        PktcNcsEndPntConfigEntry
      MAX-ACCESS    not-accessible
      STATUS        current
      DESCRIPTION   
            "Entries in pktcNcsEndPntConfigTable - Each entry 
            describes what signaling type a particular endpoint uses."
      INDEX { ifIndex }
      ::=  { pktcNcsEndPntConfigTable 1 }

PktcNcsEndPntConfigEntry  ::= SEQUENCE {
      pktcNcsEndPntConfigCallAgentId            SnmpAdminString,
      pktcNcsEndPntConfigCallAgentUdpPort       Integer32,
      pktcNcsEndPntConfigPartialDialTO          Integer32,
      pktcNcsEndPntConfigCriticalDialTO         Integer32,
      pktcNcsEndPntConfigBusyToneTO             Integer32,
      pktcNcsEndPntConfigDialToneTO             Integer32,
      pktcNcsEndPntConfigMessageWaitingTO       Integer32,
      pktcNcsEndPntConfigOffHookWarnToneTO      Integer32,
      pktcNcsEndPntConfigRingingTO              Integer32,
      pktcNcsEndPntConfigRingBackTO             Integer32,
      pktcNcsEndPntConfigReorderToneTO          Integer32,
      pktcNcsEndPntConfigStutterDialToneTO      Integer32,
      pktcNcsEndPntConfigTSMax                  Integer32,
      pktcNcsEndPntConfigMax1                   Integer32,
      pktcNcsEndPntConfigMax2                   Integer32,
      pktcNcsEndPntConfigMax1QEnable            TruthValue,
      pktcNcsEndPntConfigMax2QEnable            TruthValue,
      pktcNcsEndPntConfigMWD                    Integer32,
      pktcNcsEndPntConfigTdinit                 Integer32,
      pktcNcsEndPntConfigTdmin                  Integer32,
      pktcNcsEndPntConfigTdmax                  Integer32,
      pktcNcsEndPntConfigRtoMax                 Integer32,
      pktcNcsEndPntConfigRtoInit                Integer32,
      pktcNcsEndPntConfigLongDurationKeepAlive  Integer32,
      pktcNcsEndPntConfigThist                  Integer32,
      pktcNcsEndPntConfigStatus                 RowStatus,
      pktcNcsEndPntConfigCallWaitingMaxRep      Integer32,
      pktcNcsEndPntConfigCallWaitingDelay     Integer32,
      pktcNcsEndPntStatusCallIpAddress        IpAddress,
      pktcNcsEndPntStatusError                INTEGER
      }

pktcNcsEndPntConfigCallAgentId     OBJECT-TYPE
      SYNTAX     SnmpAdminString(SIZE (3..255))
      MAX-ACCESS read-create
      STATUS     current
      DESCRIPTION
            "This object contains a string indicating the call agent 
            name(e.g.: ca@abc.def.com). The call agent name 
            after the character '@', MUST be a fully qualified 
            domain name and MUST have a corresponding 
            pktcMtaDevCmsFqdn entry in the pktcMtaDevCmsTable.  For 
            each particular end-point, the MTA MUST use the current 
            value of this object to communicate with the corresponding
            CMS.  The MTA MUST update this object with the value of the
            'Notified Entity' parameter of the NCS message.  If the 
            Notified Entity parameter does not contain a CallAgent 
            port, the MTA MUST update this object with default value 
            of 2727.  Because of the high importance of this object to
            the ability of the MTA to maintain reliable NCS 
            communication with the CMS, it is highly recommended not 
            to change this object's value through management station
            during normal operations."

    ::= {  pktcNcsEndPntConfigEntry 1 }

pktcNcsEndPntConfigCallAgentUdpPort    OBJECT-TYPE
      SYNTAX    Integer32 (1025..65535)
      MAX-ACCESS   read-create 
      STATUS       current
      DESCRIPTION
            "This object contains the current value of the User 
            Datagram Protocol (UDP) receive port on which the call 
            agent will receive NCS signaling from the endpoint. 
            For each particular end-point, the MTA MUST use 
            the current value of this object to communicate with the 
            corresponding CMS.  The MTA MUST update this 
            object with the value of the 'Notified Entity' parameter 
            of the NCS message.  If the Notified Entity 
            parameter does not contain a CallAgent port, the MTA MUST 
            update this object with default value of 2727. 
            Because of the high importance of this object to the 
            ability of the MTA to maintain reliable NCS communication 
            with the CMS, it is highly recommended not to change this 
            object's value through management station during normal 
            operations."
      REFERENCE
            "Refer to NCS specification"
      DEFVAL    { 2727 }
      ::= { pktcNcsEndPntConfigEntry 2 }

pktcNcsEndPntConfigPartialDialTO     OBJECT-TYPE
      SYNTAX       Integer32
      UNITS        "seconds"
      MAX-ACCESS   read-create
      STATUS       current
      DESCRIPTION
            "This object contains maximum value of the partial 
             dial time out."
      REFERENCE
            "Refer to PacketCable NCS specification"
      DEFVAL { 16 }
      ::= { pktcNcsEndPntConfigEntry 3 }


pktcNcsEndPntConfigCriticalDialTO     OBJECT-TYPE
      SYNTAX    Integer32
      UNITS        "seconds"
      MAX-ACCESS    read-create
      STATUS    current
      DESCRIPTION
            "This object contains the maximum value of the critical 
            dial time out."
      REFERENCE
            "Refer NCS specification"
      DEFVAL { 4 }
      ::= { pktcNcsEndPntConfigEntry 4 }

pktcNcsEndPntConfigBusyToneTO     OBJECT-TYPE
      SYNTAX    Integer32
      UNITS        "seconds"
      MAX-ACCESS   read-create
      STATUS       current
      DESCRIPTION
            "This object contains the default timeout value for busy
            tone.The MTA MUST NOT update this object with the
            value provided in the NCS Message (if present). 
            If the value of the object is modified by the 
            SNMP Management Station, the MTA MUST use the new value as
            a default only for a new signal requested by the NCS 
            message."   
      REFERENCE
            "Refer to NCS specification"
      DEFVAL    { 30 }
      ::= { pktcNcsEndPntConfigEntry 5 }

pktcNcsEndPntConfigDialToneTO     OBJECT-TYPE
      SYNTAX    Integer32
      UNITS        "seconds"
      MAX-ACCESS   read-create
      STATUS       current
      DESCRIPTION
            "This object contains the default timeout value for dial
             tone. The MTA MUST NOT update this object with
             the value provided in the NCS Message (if present). 
             If the value of the object is modified by the 
             SNMP Management Station, the MTA MUST use the new value
             as a default only for a new signal requested by the NCS
             message."   
      REFERENCE
            "Refer to NCS specification "
      DEFVAL    { 16 }
      ::= { pktcNcsEndPntConfigEntry 6 }

pktcNcsEndPntConfigMessageWaitingTO     OBJECT-TYPE
      SYNTAX    Integer32
      UNITS        "seconds"
      MAX-ACCESS    read-create
      STATUS    current
      DESCRIPTION
            "This object contains the default timeout value for 
            message waiting indicator The MTA MUST NOT 
            update this object with the value provided in the NCS 
            Message (if present).  If the value of the object
            is modified by the SNMP Management Station, the MTA MUST 
            use the new value as a default only for a new signal 
            requested by the NCS message."   
      REFERENCE
            "Refer to NCS specification"
      DEFVAL    { 16 }
      ::= { pktcNcsEndPntConfigEntry 7 }

pktcNcsEndPntConfigOffHookWarnToneTO     OBJECT-TYPE
      SYNTAX    Integer32
      UNITS        "seconds"
      MAX-ACCESS   read-create
      STATUS       current
      DESCRIPTION
            "This object contains the default timeout value for the
            off hook Warning tone. The MTA MUST NOT update
            this object with the value provided in the NCS Message (if
            present).  If the value of the object is modified
            by the SNMP Management Station, the MTA MUST use the new 
            value as a default only for a new signal requested by the 
            NCS message. "  
      REFERENCE
            "Refer to NCS specification"
      DEFVAL { 0 }
      ::= { pktcNcsEndPntConfigEntry 8 }

pktcNcsEndPntConfigRingingTO     OBJECT-TYPE
      SYNTAX    Integer32
      UNITS        "seconds"
      MAX-ACCESS    read-create
      STATUS    current
      DESCRIPTION
            "This object contains the default timeout value for 
            ringing. The MTA MUST NOT update this object with
            the value provided in the NCS Message (if present). 
            If the value of the object is modified by the 
            SNMP Management Station, the MTA MUST use the new value 
            as a default only for a new signal requested by the NCS
            message."   
      REFERENCE
            "Refer to NCS specification"
      DEFVAL    { 180 }
      ::= { pktcNcsEndPntConfigEntry 9 }

pktcNcsEndPntConfigRingBackTO     OBJECT-TYPE
      SYNTAX    Integer32
      UNITS        "seconds"
      MAX-ACCESS    read-create
      STATUS    current
      DESCRIPTION
            "This object contains the default timeout value for ring 
            back. The MTA MUST NOT update this object with 
            the value provided in the NCS Message (if present). 
            If the value of the object is modified by the 
            SNMP Management Station, the MTA MUST use the new value as
            a default only for a new signal requested by the NCS 
            message."   
      REFERENCE
            "Refer to NCS specification"
      DEFVAL    { 180 }
      ::= { pktcNcsEndPntConfigEntry 10 }

pktcNcsEndPntConfigReorderToneTO     OBJECT-TYPE
      SYNTAX    Integer32
      UNITS        "seconds"
      MAX-ACCESS    read-create
      STATUS    current
      DESCRIPTION
            "This object contains the default timeout value for 
            reorder tone. The MTA MUST NOT update this 
            object with the value provided in the NCS Message (if 
            present).  If the value of the object is modified 
            by the SNMP Management Station, the MTA MUST use the new
            value as a default only for a new signal requested by 
            the NCS message."  
      REFERENCE
            "Refer to NCS specification"
      DEFVAL    { 30 }
      ::= { pktcNcsEndPntConfigEntry 11 }

pktcNcsEndPntConfigStutterDialToneTO     OBJECT-TYPE
      SYNTAX    Integer32
      UNITS        "seconds"
      MAX-ACCESS    read-create
      STATUS    current
      DESCRIPTION
            "This object contains the default timeout value for
            stutter dial tone. The MTA MUST NOT update this
            object with the value provided in the NCS Message (if 
            present).  If the value of the object is modified
            by the SNMP Management Station, the MTA MUST use the new 
            value as a default only for a new signal requested by the
            NCS message."   
      REFERENCE
          "Refer to NCS specification"
      DEFVAL    { 16 }
      ::= { pktcNcsEndPntConfigEntry 12 }

pktcNcsEndPntConfigTSMax     OBJECT-TYPE
      SYNTAX      Integer32
      MAX-ACCESS    read-create
      STATUS    current
      DESCRIPTION
            "This object contains the max time in seconds since the 
            sending of the initial datagram."
      REFERENCE
            "Refer to NCS specification"
      DEFVAL { 20 }
      ::= { pktcNcsEndPntConfigEntry 13 }

pktcNcsEndPntConfigMax1     OBJECT-TYPE
      SYNTAX      Integer32
      MAX-ACCESS    read-create
      STATUS    current
      DESCRIPTION
            "This object contains the suspicious error threshold 
            for signaling messages."
      REFERENCE
            "Refer to NCS specification"
      DEFVAL { 5 }
      ::= { pktcNcsEndPntConfigEntry 14 }

 
pktcNcsEndPntConfigMax2     OBJECT-TYPE
      SYNTAX      Integer32
      MAX-ACCESS    read-create
      STATUS    current
      DESCRIPTION
            "This object contains the disconnect error 
            threshold for signaling messages."
      REFERENCE
            "Refer to NCS specification"
      DEFVAL { 7 }
      ::= { pktcNcsEndPntConfigEntry 15 }

pktcNcsEndPntConfigMax1QEnable     OBJECT-TYPE
      SYNTAX      TruthValue
      MAX-ACCESS    read-create
      STATUS    current
      DESCRIPTION
            "This object enables/disables the Max1 Domain Name
            Server (DNS) query operation when Max1 expires."
      DEFVAL { true }
      ::= { pktcNcsEndPntConfigEntry 16 }

pktcNcsEndPntConfigMax2QEnable     OBJECT-TYPE
      SYNTAX      TruthValue
      MAX-ACCESS    read-create
      STATUS    current
      DESCRIPTION
            "This object enables/disables the Max2 DNS query
            operation when Max2 expires."
      DEFVAL { true }
      ::= { pktcNcsEndPntConfigEntry 17 }

pktcNcsEndPntConfigMWD     OBJECT-TYPE
      SYNTAX      Integer32
      UNITS     "seconds"
      MAX-ACCESS    read-create
      STATUS    current
      DESCRIPTION
            "Maximum Waiting Delay (MWD) contains the maximum 
            number of seconds a MTA waits after a restart."
      REFERENCE
            "Refer to NCS specification"
      DEFVAL { 600 }
      ::= { pktcNcsEndPntConfigEntry 18 }


pktcNcsEndPntConfigTdinit     OBJECT-TYPE
      SYNTAX      Integer32
      UNITS     "seconds"
      MAX-ACCESS    read-create
      STATUS    current
      DESCRIPTION
            "This object contains the initial number of seconds 
            a MTA waits after a disconnect."
      REFERENCE
            "Refer to NCS specification"
      DEFVAL { 15 }
      ::= { pktcNcsEndPntConfigEntry 19 }

pktcNcsEndPntConfigTdmin     OBJECT-TYPE
      SYNTAX      Integer32
      UNITS     "seconds"
      MAX-ACCESS    read-create
      STATUS    current
      DESCRIPTION
            "This object contains the minimum number of seconds a 
            MTA waits after a disconnect."
      REFERENCE
            "Refer to NCS specification"
      DEFVAL { 15 }
      ::= { pktcNcsEndPntConfigEntry 20 }

pktcNcsEndPntConfigTdmax     OBJECT-TYPE
      SYNTAX      Integer32
      UNITS     "seconds"
      MAX-ACCESS    read-create
      STATUS    current
      DESCRIPTION
            "This object contains the maximum number of seconds 
            a MTA waits after a disconnect."
      REFERENCE
            "Refer to NCS specification"
      DEFVAL { 600 }
      ::= { pktcNcsEndPntConfigEntry 21 }

pktcNcsEndPntConfigRtoMax     OBJECT-TYPE
      SYNTAX      Integer32
      UNITS     "seconds"
      MAX-ACCESS    read-create
      STATUS    current
      DESCRIPTION
            "This object contains the maximum number of seconds 
            for the retransmission timer."
      REFERENCE
            "Refer to NCS specification"
      DEFVAL { 4 }
      ::= { pktcNcsEndPntConfigEntry 22 }


pktcNcsEndPntConfigRtoInit     OBJECT-TYPE
      SYNTAX      Integer32
      UNITS          "milliseconds"
      MAX-ACCESS    read-create
      STATUS    current
      DESCRIPTION
            "This object contains the initial number of seconds 
            for the retransmission timer."
      REFERENCE
            "Refer to NCS specification"
      DEFVAL { 200 }
      ::= { pktcNcsEndPntConfigEntry 23 }

pktcNcsEndPntConfigLongDurationKeepAlive     OBJECT-TYPE
      SYNTAX      Integer32
      UNITS     "minutes"
      MAX-ACCESS    read-create
      STATUS    current
      DESCRIPTION
            "Specifies a timeout value in minutes for sending 
            long duration call notification message."
      REFERENCE
            "Refer to NCS specification"
      DEFVAL { 60 }
      ::= { pktcNcsEndPntConfigEntry 24 }

pktcNcsEndPntConfigThist  OBJECT-TYPE
      SYNTAX    Integer32
      UNITS     "seconds"
      MAX-ACCESS    read-create
      STATUS    current
      DESCRIPTION
            "Timeout period in seconds before no response is 
            declared."
      REFERENCE
            "Refer to NCS specification"
      DEFVAL { 30 }
      ::= { pktcNcsEndPntConfigEntry 25 }

pktcNcsEndPntConfigStatus     OBJECT-TYPE
      SYNTAX      RowStatus
      MAX-ACCESS    read-create
      STATUS    current
      DESCRIPTION
            "This object contains the Row Status associated with 
            the pktcNcsEndPntConfigTable."
      ::= { pktcNcsEndPntConfigEntry 26 }

pktcNcsEndPntConfigCallWaitingMaxRep     OBJECT-TYPE
      SYNTAX    Integer32 (0..10)
      MAX-ACCESS    read-create
      STATUS    current
      DESCRIPTION
            "This object contains the default value of the maximum
            number of repetitions of the call waiting tone that the
            MTA will play from a single CMS request. The MTA 
            MUST NOT update this object with the information provided
            in the NCS Message (if present).  If the value of
            the object is modified by the SNMP Management Station, 
            the MTA MUST use the new value as a default only for a new 
            signal requested by the NCS message." 
      DEFVAL    { 1 }
      ::= { pktcNcsEndPntConfigEntry 27 }

pktcNcsEndPntConfigCallWaitingDelay     OBJECT-TYPE
      SYNTAX    Integer32 (1..100)
      UNITS "seconds"
      MAX-ACCESS    read-create
      STATUS    current
      DESCRIPTION
            "This object contains the delay between repetitions
            of the call waiting tone that the MTA will play from 
            a single CMS request."
      DEFVAL    { 10 }
      ::= { pktcNcsEndPntConfigEntry 28 }

pktcNcsEndPntStatusCallIpAddress  OBJECT-TYPE    
      SYNTAX IpAddress    
      MAX-ACCESS read-only    
      STATUS current    
      DESCRIPTION    
            "This object contains the IP address of the CMS 
            currently being used for this endpoint. This IP 
            address is used to create the appropriate security 
            association."
      ::= { pktcNcsEndPntConfigEntry 29 }

pktcNcsEndPntStatusError  OBJECT-TYPE    
      SYNTAX INTEGER {
            operational           (1), 
            noSecurityAssociation (2), 
            disconnected          (3) 
      }
      MAX-ACCESS   read-only    
      STATUS       current    
      DESCRIPTION
            "This object contains the error status for this interface.
            The operational state indicates that all operations 
            necessary to put the line in service have occurred and CMS 
            has acknowledged the RSIP message successfully.
            If 'pktcMtaDevCmsIpsecCtrl' is enabled for the associated 
            Call Agent, the noSecurityAssociation status indicates 
            that no Security Association (SA) yet exists for this 
            endpoint. Otherwise, the state is unused.
            The disconnected status indicates one of the following two:
            1. If 'pktcMtaDevCmsIpsecCtrl' is disabled then no 
            security association is involved with this endpoint: the 
            NCS signaling Software is in process of establishing the 
            NCS signaling Link via an RSIP exchange.
            2. Otherwise, pktcMtaDevCmsIpsecCtrl is enabled, the 
            security Association has been established and the NCS 
            signaling Software is in process of establishing the NCS
            signaling Link via an RSIP exchange."

      ::= { pktcNcsEndPntConfigEntry 30 }
--
-- notification group is for future extension.
-- 
pktcSigNotificationPrefix OBJECT IDENTIFIER     ::= { pktcSigMib 2 }
pktcSigNotification  OBJECT IDENTIFIER     ::= {
 pktcSigNotificationPrefix 0 }
pktcSigConformance   OBJECT IDENTIFIER     ::= { pktcSigMib 3 }
pktcSigCompliances   OBJECT IDENTIFIER     ::= { pktcSigConformance 1 }
pktcSigGroups        OBJECT IDENTIFIER     ::= { pktcSigConformance 2 }


-- compliance statements

pktcSigBasicCompliance  MODULE-COMPLIANCE
      STATUS     current
      DESCRIPTION
        "The compliance statement for devices that implement Signaling
        on the MTA."
       
MODULE  -- pktcSigMib

-- unconditionally mandatory groups

MANDATORY-GROUPS {
      pktcSigGroup
      }
      GROUP pktcNcsGroup
      DESCRIPTION 
            "This group is mandatory for any MTA implementing NCS
            signaling"
      ::={ pktcSigCompliances 1 }

-- units of conformance

pktcSigGroup  OBJECT-GROUP
      OBJECTS {
      pktcSigDevCodecType,
      pktcSigDevCodecMax,
      pktcSigDevEchoCancellation,
      pktcSigDevSilenceSuppression,
      pktcSigDevConnectionMode,    
      pktcSigDevR0Cadence,
      pktcSigDevR6Cadence,
      pktcSigDevR7Cadence,
      pktcSigDefCallSigTos,
      pktcSigDefMediaStreamTos,
      pktcSigTosFormatSelector,
      pktcSignalingType,
      pktcSignalingVersion,
      pktcSignalingVendorExtension,
      pktcSigEndPntCapabilityIndex,
      pktcSigDefNcsReceiveUdpPort,
      pktcSigDevR1Cadence,
      pktcSigDevR2Cadence,
      pktcSigDevR3Cadence,
      pktcSigDevR4Cadence,
      pktcSigDevR5Cadence,
      pktcSigDevRgCadence,
      pktcSigDevRsCadence,
      pktcSigDevRtCadence
      }
      STATUS current
      DESCRIPTION
          "Group of objects for the common portion of the
          PacketCable Signaling MIB."
      ::= { pktcSigGroups 1 } 

pktcNcsGroup  OBJECT-GROUP
      OBJECTS {
      pktcNcsEndPntConfigCallAgentId,
     pktcNcsEndPntConfigCallAgentUdpPort,
      pktcNcsEndPntConfigPartialDialTO,
      pktcNcsEndPntConfigCriticalDialTO,
      pktcNcsEndPntConfigBusyToneTO,
      pktcNcsEndPntConfigDialToneTO,
      pktcNcsEndPntConfigMessageWaitingTO,
      pktcNcsEndPntConfigOffHookWarnToneTO,
      pktcNcsEndPntConfigRingingTO,
      pktcNcsEndPntConfigRingBackTO,
      pktcNcsEndPntConfigReorderToneTO,
      pktcNcsEndPntConfigStutterDialToneTO,
      pktcNcsEndPntConfigTSMax,
      pktcNcsEndPntConfigMax1,
      pktcNcsEndPntConfigMax2,
      pktcNcsEndPntConfigMax1QEnable,
      pktcNcsEndPntConfigMax2QEnable,
      pktcNcsEndPntConfigMWD,
      pktcNcsEndPntConfigTdinit,
      pktcNcsEndPntConfigTdmin,
      pktcNcsEndPntConfigTdmax,
      pktcNcsEndPntConfigRtoMax,
      pktcNcsEndPntConfigRtoInit,
      pktcNcsEndPntConfigLongDurationKeepAlive,
      pktcNcsEndPntConfigThist,
      pktcNcsEndPntConfigStatus,
      pktcNcsEndPntConfigCallWaitingMaxRep,
      pktcNcsEndPntConfigCallWaitingDelay,
      pktcNcsEndPntStatusCallIpAddress,
      pktcNcsEndPntStatusError
      }
      STATUS current
      DESCRIPTION
            "Group of objects for the NCS portion of the
            PacketCable Signaling MIB.  This is mandatory for
            NCS signaling."
      ::= { pktcSigGroups 2 } 

pktcSigObsoleteGroup  OBJECT-GROUP
      OBJECTS {
            pktcSigServiceClassNameUS,
            pktcSigServiceClassNameDS,
            pktcSigServiceClassNameMask,
            pktcSigNcsServiceFlowState  
      }
      STATUS  obsolete
      DESCRIPTION
            " Collection of obsolete objects for PacketCable 
            Signaling MIB."
      ::= { pktcSigGroups 3}
END

