-- Redline AN-50 MIB
-- ECO Rev 1.00
-- ECO Rev 1.0x
-- Copyright (c) 2006 by Redline Communications, Inc.
-- All rights reserved.
-- *****************************************************************

REDLINE-AN50-MIB DEFINITIONS ::= BEGIN
 
IMPORTS

        IpAddress, Counter, TimeTicks, enterprises  FROM RFC1155-SMI
        OBJECT-TYPE  FROM RFC-1212
        TRAP-TYPE    FROM RFC-1215
	  an50pmpLastModifiedCID,
	  an50pmpLastMissedSsMacAddress,
	  an50pmpLastRegisteredSsMacAddress  FROM REDLINE-AN50-PMP-V1-MIB;


--      ORGANIZATION "Redline Communications, Inc."

--      postal:  Redline Communications Inc.
--              302 Town Centre Suite 100
--              Markham Ontario L3R 0E8
--              Canada
--      phone:     +1 905 479-8344
--      DESCRIPTION "This MIB contains Redline-defined AN-50 attributes."

--      LAST-UPDATED "200307240930Z"
--      Author: Sinisa Djurkic
--      DESCRIPTION "New variables for PMP project intoduced."

--      REVISION "200307110930Z"
--      Author: Sinisa Djurkic
--      DESCRIPTION "Introduced OIDs for the AN30 application."

--      REVISION "200301080930Z"
--      Author: Sinisa Djurkic
--      DESCRIPTION "New AN-50 terminology and new powersupply trap introduced."

--      REVISION  "200212121145Z"
--      Author: Sinisa Djurkic
--      Appreciation: Aurel Picu, Alex Parvulescu
--      DESCRIPTION "Added scalars for front plate and chassis."

--      REVISION    "200211030000Z"
--      Author: Sinisa Djurkic
--      Appreciation: Aurel Picu
--      DESCRIPTION "Added scalars from mib-II interface tree."

--      REVISION    "200210210000Z"
--      Author: Sinisa Djurkic
--      Appreciation: Aurel Picu, Claude Daniel Ndjouou
--      DESCRIPTION "MIB overhauled, complete V1 conversion."

--      REVISION    "200204090000Z"
--      Primary Author: Claude Daniel Ndjouou, Ioan Cautil
--      DESCRIPTION "Initial version of this MIB module."

--      REVISION    "200308200000Z"
--      Author: Bogdan Moldoveanu
--      DESCRIPTION "Added an50GenChannelAutoScan and the trap an50ModifiedIDTrap."

--      REVISION    "200401070000Z"
--      Author: Bogdan Moldoveanu
--      DESCRIPTION "Added an50WrlsDFSAction an50WrlsAntennaGain,an50WrlsATPEnabled and trap an50pmpRegistrationMissed "

--      REVISION    "200401080000Z"
--      Author: Bogdan Moldoveanu
--      DESCRIPTION "Added trap an50pmpRegistrationSuccessful "

--      REVISION    "200401270000Z"
--      Author: Bogdan Moldoveanu
--      DESCRIPTION "Added trap an50DFSEvent"

--      REVISION    "200408040000Z"
--      Author: Ioan Cautil
--      DESCRIPTION "Completed descriptions of mib nodes"

--      REVISION    "200601160000Z"
--      Author: Mark Fairclough c/o Radu Morus
--      DESCRIPTION "Added an50etherMgmVid and an50etherLben OIDs"

-- Registration of object identifiers
redline         OBJECT IDENTIFIER ::= { enterprises 10728 }
redlineProducts OBJECT IDENTIFIER ::= { redline 1 }
redlineMgmt     OBJECT IDENTIFIER ::= { redline 2 }
redlineAn50     OBJECT IDENTIFIER ::= { redlineMgmt 16} 
an50General     OBJECT IDENTIFIER ::= { redlineAn50 1 }
an50Config      OBJECT IDENTIFIER ::= { redlineAn50 2 }
an50Pm          OBJECT IDENTIFIER ::= { redlineAn50 3 }
an50Trap        OBJECT IDENTIFIER ::= { redlineAn50 4 }
an50LinkPmp     OBJECT IDENTIFIER ::= { redlineAn50 5 }

an50GenUBR OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
        "Indicates the system's current uncoded burst rate. With 
	   adaptive modulation enabled, this rate may change over time,
         depending on the prevailing propagation conditions. "
        ::= { an50General 1 }

an50GenRFLink OBJECT-TYPE
        SYNTAX  INTEGER { 
			notConnected(1), -- remote terminal not connected
			connected(2)     -- remote terminal connected
			}
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "connected(2) indicates  the  terminal  is  communicating  
		 properly  to  the remote terminal. 
             notConnected(1) indicates there is no communication with 
		 the remote terminal."
        ::= { an50General 2 }

an50GenFrequency OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "The frequency which represents the operating channel of the link. 
		The system can be configured to operate over 9 distinct channels."
        ::= { an50General 3 }

an50GenAllignmentMode OBJECT-TYPE
        SYNTAX  INTEGER { 
			voltage (1), -- antenna alignment is done with voltage
			buzzer (2)   -- antenna alignment is done with buzzer
			}
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "Specifies if the antenna alignment is done with buzzer or voltage."
        ::= { an50General 4 }

an50GenEncryptionEnabled OBJECT-TYPE
        SYNTAX  INTEGER { 
			no (1), -- encryption not enabled
			yes (2) -- encryption enabled
			}
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "Specifies if encryption is enabled or not."
        ::= { an50General 5 }

an50GenFlowControlEnabled OBJECT-TYPE
        SYNTAX  INTEGER { 
			no (1), -- flow control is not enabled 
			yes (2) -- flow control is enabled 
			}
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "This attribute specifies if flow control is enabled or not."
        ::= { an50General 6 }

an50GenHttpAccessEnabled OBJECT-TYPE
        SYNTAX  INTEGER { 
			no (1), -- Http access is not enabled 
			yes (2) -- Http access is enabled 
			}
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "This attribute specifies if Http Access is enabled or not."
        ::= { an50General 7 }

an50GenTelnetAccessEnabled OBJECT-TYPE
        SYNTAX  INTEGER { 
			no (1), -- Telnet access is not enabled 
			yes (2) -- Telnet access is enabled 
			}
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "This attribute specifies if Telnet Access is enabled or not."
        ::= { an50General 8 }

an50GenTelnetPort OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "This attribute specifies the Telnet port number."
        ::= { an50General 9 }

an50GenOptionsKey OBJECT-TYPE
        SYNTAX  OCTET STRING
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "This attribute specifies the Product Options Key."
        ::= { an50General 10 }

an50GenResetDevice OBJECT-TYPE
        SYNTAX  INTEGER { 
			donothing(1), -- do not reset the AN50 terminal
			reset(2)      -- reset the AN50 terminal
			}
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "reset(2) indicates to reset the AN50 terminal.
		 donothing(1) indicates do not reset AN50 terminal."
        ::= { an50General 11 }

an50GenFault OBJECT-TYPE
        SYNTAX  INTEGER { 
			off (1),    -- fault LED status off
			on (2),     -- fault LED status on
			unknown (3) -- fault LED status unknown
			}
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "The attribute specifies the Fault LED status of the terminal."
        ::= { an50General 12 }

an50GenTxPower OBJECT-TYPE
        SYNTAX  INTEGER (-20 .. 20)
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
        "This object specifies the actual Tx Power of the AN-50 Node in ?"
        ::= { an50General 13 }

an50GenRegisteredStations OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
        "This object specifies the actual number of configured links."
        ::= { an50General 14 }

an50GenRegisteredConnections OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
        "This object specifies the actual number of configured connections."
        ::= { an50General 15 }

an50GenActiveWirelessLinks OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
        "This object specifies the actual number of provisioned links."
        ::= { an50General 16 }

an50GenChannelAutoScan OBJECT-TYPE
	  SYNTAX  INTEGER { 
			no (1), -- Auto-Scanning disabled
			yes (2) -- Auto-Scanning enabled
			}
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
        "This object specifies the Auto-Scanning feature for the channel."
        ::= { an50General 17 }

an50GenIduType OBJECT-TYPE
	  SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
        "This object specifies the Indoor Unit Type."
        ::= { an50General 18 }

an50GenOduType OBJECT-TYPE
	  SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
        "This object specifies the Outdoor Unit Type."
        ::= { an50General 19 }

--
--  Ethernet Configuration Group
--

an50ConfigEther  	OBJECT IDENTIFIER ::= { an50Config 1 }

an50EtherMacAddress OBJECT-TYPE
        SYNTAX  OCTET STRING
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "This object specifies the Ethernet MAC address of the local terminal." 
        ::= { an50ConfigEther 1 }

an50EtherGateway OBJECT-TYPE
        SYNTAX      IpAddress
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "The IP Gateway of the AN-50 This field is used to specify 
		 the IP address of the gateway which
             the AN-50 is communicating through the core network."
        ::= { an50ConfigEther 2 }

an50EtherPortStatus OBJECT-TYPE
        SYNTAX  INTEGER { 
			down (1),   -- Ethernet Port down
			up (2),     -- Ethernet Port up
			unknown (3) -- Ethernet Port status unknown
			}
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "The attribute specifies the status of the Ethernet Port of the AN50."
        ::= { an50ConfigEther 3 }

an50EtherIP OBJECT-TYPE
        SYNTAX  IpAddress
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "The IP address of the AN-50. The default address from the factory
		 is 192.168.25.2. For the initial set-up, the terminal should not
		 be connected to the Internet network, i.e. the host computer should
		 be connected directly to the terminal Ethernet port, to  avoid  address
		 conflicts with other devices in a public network. Once the IP address
		 has been set, the terminal can be connected to  the  core  network,  
		 where  it  can  receive  either static  or  dynamic addressing (DHCP) 
		 in future configuration updates." 
        ::= { an50ConfigEther 4 }

an50EtherMask OBJECT-TYPE
        SYNTAX    IpAddress
        ACCESS    read-write
        STATUS    mandatory
        DESCRIPTION
            "The IP Subnet Mask of the AN-50. The value is typically set 
		 to 255.255.255.0 (Class C subnet), which prevents certain 
		 local devices from going out into the wireless network."
        ::= { an50ConfigEther 5 }

an50Ether100 OBJECT-TYPE
        SYNTAX  INTEGER { 
			s10Mbs (1),  -- 100 Mb/s Ethernet LED status off
			s100Mbs (2), -- 100 Mb/s Ethernet LED status on
			unknown (3)  -- 100 Mb/s Ethernet LED status unknown
			}
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "This object specifies the 100 Mb/s Ethernet LED status of the AN50."
        ::= { an50ConfigEther 6 }

an50EtherFd OBJECT-TYPE
        SYNTAX  INTEGER { 
		halfDuplex (1), -- Ethernet FullDuplex LED status off
		fullDuplex (2), -- Ethernet FullDuplex LED status on
		unknown (3)     -- Ethernet FullDuplex LED status unknown
		}
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "The object specifies the Ethernet FullDuplex LED status of the AN50."
        ::= { an50ConfigEther 7 }

an50EtherMgmVidEn OBJECT-TYPE
        SYNTAX  INTEGER {  no (1), yes (2) }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "The attribute specifies the Ethernet Management Vlan Enabled Status of the AN50."
        ::= { an50ConfigEther 8 }

an50EtherMgmVid OBJECT-TYPE
        SYNTAX  INTEGER ( 0..4095 )
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "The attribute specifies the Ethernet Management Vlan Id of the AN50."
        ::= { an50ConfigEther 9 }

an50EtherLben OBJECT-TYPE
        SYNTAX  INTEGER {  no (1), yes (2) }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "The attribute specifies the Link Backup Enable Status of the AN50."
        ::= { an50ConfigEther 10 }

--
--  Wireless Configuration Group
--

an50ConfigWireless  	OBJECT IDENTIFIER ::= { an50Config 2 }

an50WrlsChannel OBJECT-TYPE
        SYNTAX  INTEGER { 
			chan1 (1),  -- 5735 MHz
			chan1A (2), -- 5745 MHz
			chan2 (3),  -- 5755 MHz
			chan2A (4), -- 5765 MHz
		      chan3 (5),  -- 5775 MHz
			chan3A (6), -- 5785 MHz
			chan4 (7),  -- 5795 MHz
			chan4A (8), -- 5805 MHz
			chan5 (9)   -- 5815 MHz
			}
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "specifies the  operating  channel  of  the  system,  
		within the 100 MHz available in the 5.8GHz UNII band. 
		To  avoid  interference, two PTP links  operating  in  
		the  same  physical location (co-located) or within close 
		proximity (e.g. across the street) must be separated by at 
		least one channel, i.e. the gap between channels should 
		be 20 MHz or more (e.g. channels 1 and 3)."
        ::= { an50ConfigWireless 1 }

an50WrlsTxPower OBJECT-TYPE
        SYNTAX  INTEGER (-20 .. 20)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
     	   	"The Tx Power of the AN-50 in dBm. Specifies the power level of the system, 
		which is preset at the factory  and should not be altered.  In the event 
		that this parameter needs to be changed, please contact the 
		Redline support team."
        ::= { an50ConfigWireless 2 }

an50WrlsModReduction OBJECT-TYPE
        SYNTAX  INTEGER (0..7)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "The Modulation Reduction Level of the AN-50. Applies  when  the  
		Adaptive rate is  disabled. Specifies how many levels the system 
		must drop in modulation before beginning re-transmission to address 
		packet errors. 
		The value can be set from 1-7, with 2 being the typical value."
        ::= { an50ConfigWireless 3 }

an50WrlsAdaptiveMod OBJECT-TYPE
         SYNTAX  INTEGER { 
		notAdaptiveRate(1), -- do not operate in adaptive modulation mode
		adaptiveRate(2)     -- operate in adaptive modulation mode
		}
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION 
		"Setting this attribute to AdaptiveRate(2) sets the system 
		to operate in adaptive modulation mode. It is recommended 
		to keep the AN-50 in this mode so that the system can 
		automatically adjust the modulation level to the highest possible 
		data rate based on measured RF performance. The user 
		can define the minimum desired modulation level by setting the 
		Main rate parameter.
		If the  system  meets this data  rate, then the Signal LED on the front
		panel will light continuously green. If packet errors exceed 
		one out of a million, the system will automatically lower the modulation
		level to maintain the link. In this case, the LED will flash green.   
		If errors continue when the system reaches the lowest modulation level, 
		the LED will flash red to indicate a failed RF link.  
		The user can also disable the dynamic modulation mode by disabling
		Adaptive Modulation. In this mode, the user is required to set the 
		Burst Rate and the Modulation Reduction Level. It is recommended not 
		to operate the system in manual mode, as this mode is intended primarily 
		for field support.
		Note the Signal LED will light solid green when the packet error rate is 
		less than 1 out of a million. When  the errors exceed this limit, the LED 
		will not illuminate, indicating the RF link has failed."
        ::= { an50ConfigWireless 4 }

an50WrlsUBR OBJECT-TYPE
        SYNTAX  INTEGER (0..7)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
        	"This object contains the desired net uncoded burst rate for the link.
		 Set uncoded burst rate in steps (0=6Mb/s, 1=9Mb/s, 2=12Mb/s, 
		 3=18Mb/s, 4=24Mb/s, 5=36Mb/s, 6=48Mb/s, 7=54Mbs)."
        ::= { an50ConfigWireless 5 }

an50WrlsMaster OBJECT-TYPE
        SYNTAX INTEGER { 
			ptpSlave(1),  -- device is configured as a PTP Slave
			ptpMaster(2), -- device is configured as a PTP Master
			pmpSlave(3),  -- device is configured as a PMP Slave
			pmpMaster(4)  -- device is configured as a PMP Master
			}
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
		"The object contains the configured mode of the AN50 terminal.
		1 = PTP Slave, 2 = PTP Master, 3 = PMP Slave, 4 = PMP Master"
        ::= { an50ConfigWireless 6 }

an50WrlsVersion OBJECT-TYPE
        SYNTAX INTEGER { 
		firstFlash(1), -- use the software from the first flash memory
		secondFlash(2) -- use the software from the second flash memory
		}
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION 
		"Sets the version of the AN50 system software. The software 
             can be remotely downloaded into the AN50. The system 
             comprises sufficient memory to hold two independent software loads.
             The operator can specify which load to set as the active version."
        ::= { an50ConfigWireless 7 }

an50WrlsEncryptCode OBJECT-TYPE
        SYNTAX  OCTET STRING
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "The object contains the Encryption Key used for the 
		 AN-50 terminal. Enter the MAC address of the remote 
             terminal to enable over-the-air data encryption."
        ::= { an50ConfigWireless 8 }

an50WrlsCableAttenuation OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "This object contains the Cable Attenuation for the AN-50 in dB."
        ::= { an50ConfigWireless 9 }

an50WrlsRfPortStatus OBJECT-TYPE
        SYNTAX  INTEGER { 
			down (1),   -- AN50s Wireless Port down
			up (2),     -- AN50s Wireless Port up
			unknown (3) -- AN50s Wireless Port status unknown
			}
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "The object specifies the status of the AN50s Wireless Port."
        ::= { an50ConfigWireless 10 }

an50WrlsSaveConfig OBJECT-TYPE
        SYNTAX  INTEGER { 
		donothing(1), -- do not save the config set of the AN50
		saveConfig(2)  -- save the entire config set of the AN50
		}
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "The object saves the entire config set of the AN50."
        ::= { an50ConfigWireless 11 }

an50WrlsActivateConfig OBJECT-TYPE
        SYNTAX  INTEGER { 
		donothing(1),  -- do not activate the config set of the AN50
		activeConfig(2) -- activate the entire config set of the AN50
		}
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "The object activates the entire config set of the AN50."
        ::= { an50ConfigWireless 12 }

an50WrlsRadioEnable OBJECT-TYPE
        SYNTAX  INTEGER { 
			txOff (1), -- radio transmission is disabled 
			txOn (2)   -- radio transmission is enabled 
			}
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "The object specifies whether radio transmission is enabled or disabled."
        ::= { an50ConfigWireless 13 }

an50WrlsRfStatusErrorCode OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "The object specifies the Error Code for the RF Status."
        ::= { an50ConfigWireless 14 }

an50WrlsRfSignal OBJECT-TYPE
        SYNTAX  INTEGER { 
		off (1),    -- Wireless Signal LED status off
		on (2),     -- Wireless Signal LED status on
		blinking(3) -- Wireless Signal LED status blinking
		}
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "The object specifies the Wireless Signal LED status."
        ::= { an50ConfigWireless 15 }


an50WrlsLLMode OBJECT-TYPE
        SYNTAX  INTEGER { 
			auto (1),  -- Link length set automatically
			manual (2) -- Link length set manually
			}
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "Link length set mode."
        ::= { an50ConfigWireless 16 }

an50WrlsLMU OBJECT-TYPE
        SYNTAX  INTEGER { 
			mile (1), -- link measurement unit in mile
			km (2)    -- link measurement unit in Km
			}
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "This object specifies the Link measurements unit (mile / Km)."
        ::= { an50ConfigWireless 17 }

an50WrlsLL OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "This object specifies the Link Length. 
		 See an50WrlsLMU object for units."
        ::= { an50ConfigWireless 18 }


an50ConfigScheduler OBJECT IDENTIFIER ::= { an50ConfigWireless 19 }

an50WrlsFrameSize OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "This object specifies the size of wireless frame (DL+RTD+UL)
		 in micro seconds."
        ::= { an50ConfigScheduler 1 }

an50WrlsMinBlockSize OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "This object specifies a minimum number of bytes comprising 
		 transmitted block."
        ::= { an50ConfigScheduler 2 }

an50WrlsDownlinkSize OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "This object specifies the size of downlink sub-frame in micro seconds."
        ::= { an50ConfigScheduler 3 }

an50WrlsRoundTripDelay OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "This object specifies the round trip delay in micro seconds."
        ::= { an50ConfigScheduler 4 }

an50WrlsAdaptiveDLSize OBJECT-TYPE
        SYNTAX  INTEGER { 
			off (1), -- adaptive downlink size disabled
			on (2)   -- adaptive downlink size enabled
			}
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "This object specifies if adaptive downlink size is 
		 enabled or disabled."
        ::= { an50ConfigScheduler 5 }

an50WrlsExtSyncronize OBJECT-TYPE
        SYNTAX  INTEGER { 
			off (1), -- external synchronization disabled
			on (2)   -- external synchronization enabled
			}
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "This object specifies if external synchronization is
		 enabled or disabled."
        ::= { an50ConfigScheduler 6 }

an50WrlsMaximumDistance OBJECT-TYPE
        SYNTAX  INTEGER (0..100)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "This object specifies the maximum distance between 
		 base station and subscriber station in Km."
        ::= { an50ConfigScheduler 7 }

an50WrlsRegistrationPeriod OBJECT-TYPE
        SYNTAX  INTEGER (0..100)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "This object specifies the number of frames between registration periods."
        ::= { an50ConfigScheduler 8 }


--
-- Config Default Group
--
an50ConfigDefGroup OBJECT IDENTIFIER ::= { an50ConfigWireless 20 }
an50WrlsBroadcastDLCIR OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "This object specifies the broadcast downlink commited rate in kb/s."
        ::= { an50ConfigDefGroup 1 }

an50WrlsBroadcastDLPIR OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "This object specifies the broadcast downlink peak rate in kb/s."
        ::= { an50ConfigDefGroup 2 }

an50WrlsDFSAction OBJECT-TYPE
        SYNTAX  INTEGER { 
			none (1),      -- none
			txDisabled(2), -- transmission disabled
			changeFreq(3)  -- change frequency
			}
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "This object specifies the action taken when another system 
		 is detected on the same frequency"
        ::= { an50ConfigWireless 21 }

an50WrlsAntennaGain OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "Antenna Gain in dB."
        ::= { an50ConfigWireless 22 }

an50WrlsATPEnabled OBJECT-TYPE
        SYNTAX  INTEGER { 
		no (1), -- automatic transmitted power control disabled
		yes(2)  -- automatic transmitted power control enabled
		}
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "This object specifies if the Automatic Transmitted Power Control 
		 is enabled"
        ::= { an50ConfigWireless 23 }


--
-- Performance Data Group
--

an50ResetStatistics OBJECT-TYPE
        SYNTAX INTEGER { 
		donothing(1), -- do not reset the performance statistics 
		reset(2)      -- reset the performance statistics 
		}
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "A value of reset(2) resets the performance statistics on 
		 the AN-50, a value of donothing(1) does nothing."
        ::= { an50Pm 1 }
--
-- Ethernet Performance Data Group
--
an50PmEther		OBJECT IDENTIFIER ::= { an50Pm 2 }

an50PmEtherRxPackets OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
		"This object counts the  number of ethernet packets 
		 successfully received by the local system." 
        ::= { an50PmEther 1 }

an50PmEtherRxPacketsErr OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
		"This object counts the  number of ethernet packet errors 
		 received by the local system." 
        ::= { an50PmEther 2 }

an50PmEtherTxPackets OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
		"This object counts the number of Ethernet packets 
		 transmitted by the local system." 
        ::= { an50PmEther 3 }

an50PmEtherTxPacketsErr OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
		"This object counts the number of Ethernet error packets 
		 transmitted by the local system." 
        ::= { an50PmEther 4 }

an50PmEtherRxPacketsDisc OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
		"This object counts the number of ethernet packets discarded 
		 by receiver." 
        ::= { an50PmEther 5 }

an50PmEtherTxPacketsDisc OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
		"This object counts the number of ethernet packets discarded 
		 by transmitter." 
        ::= { an50PmEther 6 }


--
-- Wireless Performance Data Group
--
an50PmWrls	OBJECT IDENTIFIER ::= { an50Pm 3 }

an50PmWrlsRxSigMin OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
		"This object indicates the minimum received signal strength  
		 measured since the last SNMP update."
        ::= { an50PmWrls 1 }

an50PmWrlsRxSigMean OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
		"This object indicates the average received signal strength 
		 measured since the last SNMP update."
        ::= { an50PmWrls 2 }

an50PmWrlsRxSigMax OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
		"This object indicates the maximum received signal strength  
		 measured since the last SNMP update"
        ::= { an50PmWrls 3 }

an50PmWrlsAvgSinAdr OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
	      "This object indicates the average signal to noise ratio measured 
		 since the last SNMP update. The ratio is based on the 
        	 digital information provided from the output of the AtoD converter."
        ::= { an50PmWrls 4 }

an50PmWrlsRxPackets OBJECT-TYPE
        SYNTAX   Counter
        ACCESS  read-only
        STATUS   mandatory
        DESCRIPTION
		"This object indicates the number of packets received 
		 over the air from the remote terminal."
        ::= { an50PmWrls 5 }

an50PmWrlsRxPacketsRetx OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION 
		"This object indicates the number of packets retransmitted 
		 over the air from the remoter terminal."
        ::= { an50PmWrls 6 }

an50PmWrlsRxPacketsDisc OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
		"This object indicates the number of packets, originating from 
		 the remote terminal lost over the air due to degradation in the RF link."
        ::= { an50PmWrls 7 }

an50PmWrlsTxPackets OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
		"This object indicates the number of wireless packets 
		 (including Ethernet frames and error correction bytes) 
		 transmitted over the air by the local terminal."
        ::= { an50PmWrls 8}

an50PmWrlsTxPacketsRetx OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION 
		"This object indicates the number of packets retransmitted 
		 over the air by the local terminal.  The retransmission scheme 
		 is based on the Acknowledge/Request (ARQ) algorithm that detects 
		 when packets are lost and makes a request to the MAC scheduler 
		 to repeat transmission of the lost packets."
        ::= { an50PmWrls 9}

an50PmWrlsTxPacketsDisc OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
		"This object indicates the total number of packets lost 
		 over the air due to degradation in the RF link."
        ::= { an50PmWrls 10}

an50PmWrlsCalcDst OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
		"This object contains the calculated link distance."
        ::= { an50PmWrls 11}

--
-- Software Upgrade Group
--

an50Sw  		OBJECT IDENTIFIER ::= { an50Config 3 }

an50SwServer OBJECT-TYPE
        SYNTAX      IpAddress
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "The address of the TFTP server used for software upgrades.
             If the address of the TFTP server is unknown, return 0.0.0.0."
        ::= { an50Sw 1 }

an50SwFilename OBJECT-TYPE
        SYNTAX      OCTET STRING (SIZE(0..32))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "The file name of the software image to be loaded into this device."
        ::= { an50Sw 2 }

an50SwAdminStatus OBJECT-TYPE
        SYNTAX INTEGER { 
			noUpgrade(1), -- 
			upgrade(2)    -- download TFTP software image using an50SwFilename
			}
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "If set to upgrade(2), the device will initiate a
             TFTP software image download using an50SwFilename.
             If the download process is interrupted by a reset or
             power failure, the device will load the previous image.
             If set to noUpgrade(1), the device will revert to the 
             previous version of the software.
             At initial startup, this object has the default value of
             noUpgrade(1)."
        ::= { an50Sw 3 }

an50SwOperStatus OBJECT-TYPE
        SYNTAX INTEGER { 
			inProgress(1),      -- TFTP download in progress
			completeSuccess(2), -- TFTP download successful
			failed(3),          -- TFTP download failed
			other(4)            -- TFTP download 
			}
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION 
		" This object shows the download status.
		 inProgress(1) indicates that a TFTP download is underway
             completeSuccess(2) indicates that the last software upgrade 
		                    was successful
             failed(3) indicates that the last attempted download
                       failed, ordinarily due to TFTP timeout."
        ::= { an50Sw 4 }

an50SwCurrentVers OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The software version currently operating in this device's flash.
             This object should be in the syntax used by the individual
             vendor to identify software versions. If it is not applicable,
             this MUST contain an empty string."
    ::= { an50Sw 5 }

an50SwOtherVers OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION 
		"The software version in the secondary flash.
             This object should be in the syntax used by the individual
             vendor to identify software versions. If it is not 
             applicable, this MUST contain an empty string."
    ::= { an50Sw 6 }

--
-- Traps Group.
--

an50SysLastTrapTime OBJECT-TYPE
    SYNTAX      	TimeTicks
    ACCESS  	read-only
    STATUS      	mandatory
    DESCRIPTION
        "The value of system.sysUpTime when the last trap was generated. If no traps
         have been generated since the last reset, this attribute has a value of 0.
         No trap is issued as a result of a change to this value."
    ::= { an50Trap 1 }


an50TftpFailTrap TRAP-TYPE
      ENTERPRISE redline
      VARIABLES { an50SwServer,
                  an50SwFilename,
                  an50SwAdminStatus, 
                  an50SwOperStatus,
                  an50SysLastTrapTime }
	DESCRIPTION 
		"An event to report the failure of a Software Download."
      ::= 1

an50TftpSuccessTrap TRAP-TYPE
      ENTERPRISE redline
      VARIABLES { an50SwServer,
                  an50SwFilename,
			an50SwAdminStatus, 
			an50SwOperStatus, 
                  an50SysLastTrapTime }
	DESCRIPTION 
		"An event to report the success of a Software Download."
      ::= 2

an50PswdChangeFailTrap TRAP-TYPE
      ENTERPRISE redline
      VARIABLES { an50SysLastTrapTime }
      DESCRIPTION 
		"An event to report the failure of a password change."
      ::= 3

an50FirmwareConfigFailTrap TRAP-TYPE
      ENTERPRISE redline
      VARIABLES { an50SysLastTrapTime }
      DESCRIPTION 
		"An event to report the failure of a firmware config."
      ::= 4

an50EepromCorruptedTrap TRAP-TYPE
      ENTERPRISE redline
      VARIABLES { an50SysLastTrapTime }
      DESCRIPTION 
		"An event to report the corruption of the EEPROM."
      ::= 5

an50PowerSupplyFailureTrap TRAP-TYPE
      ENTERPRISE redline
      VARIABLES { an50SysLastTrapTime }
      DESCRIPTION 
		"An event to report the power supply failure."
      ::= 6
   
an50SaveConfigTrap TRAP-TYPE
      ENTERPRISE redline
      VARIABLES { an50SysLastTrapTime }
      DESCRIPTION 
		"An event to report the saving of configuration"
      ::= 7

an50ModifiedIDTrap TRAP-TYPE
      ENTERPRISE redline
      VARIABLES { an50pmpLastModifiedCID,
			an50SysLastTrapTime  }
      DESCRIPTION 
		"An event to report the modification in the configuration of a CID"
      ::= 8

an50pmpRegistrationMissed TRAP-TYPE
      ENTERPRISE redline
      VARIABLES { an50pmpLastMissedSsMacAddress,
			an50SysLastTrapTime  }
      DESCRIPTION 
		"An event to report the missing of the registration by a AN50 
		 Subscriber to one BS.This trap is sent by the BS and contains 
		 the MAC address of the SS missing the registration"
      ::= 9

an50pmpRegistrationSuccessful TRAP-TYPE
      ENTERPRISE redline
      VARIABLES { an50pmpLastRegisteredSsMacAddress,
			an50SysLastTrapTime  }
      DESCRIPTION 
		"An event to report the successful registration of an AN50 
		 Subscriber to BS. This trap is sent by the BS and contains 
		 the MAC address of the newly registered SS"
      ::= 10

an50DFSEvent TRAP-TYPE
      ENTERPRISE redline
      VARIABLES { an50SysLastTrapTime  }
      DESCRIPTION 
		"An event to report a dynamic frequency selection (DFS) event in AN50"
      ::= 11

an50MaxCid	 	OBJECT-TYPE
	SYNTAX      	INTEGER (1 .. 1024)
	ACCESS  		read-only
	STATUS      	mandatory
      DESCRIPTION        	
		"The object contains the maximum number of CID for this equipment"
    ::= { an50LinkPmp 1 }

an50LinkCurrentAvailId	OBJECT-TYPE
	SYNTAX      	INTEGER
    	ACCESS  		read-only
    	STATUS      	mandatory
    	DESCRIPTION        		
		"The current available ID in the Links table that is queried by NMS before creating a new row in Link Table"
    ::= { an50LinkPmp 2 }

END