LHX-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
    enterprises, Integer32, Unsigned32	    	    	FROM SNMPv2-SMI
    MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF
    TEXTUAL-CONVENTION, DisplayString, TruthValue   	FROM SNMPv2-TC
    InetAddressType, InetAddress, InetPortNumber    	FROM INET-ADDRESS-MIB
    sysContact, sysName, sysLocation                    FROM RFC1213-MIB;

raritan MODULE-IDENTITY
    LAST-UPDATED "201701270000Z"      -- January 27, 2017
    ORGANIZATION "Raritan"
    CONTACT-INFO "
                  Author:       Raritan Americas, Inc.
                  postal:       Raritan Americas, Inc.
                                400 Cottontail Lane
                                Somerset, NJ 08873
                  email:        tech@raritan.com
                  phone:        +1 732 764 8886
                 "
    DESCRIPTION  "This MIB describes the SNMP functions of the
                  Schroff Varistar LHX heat exchanger
		  supported by Raritan devices."

    REVISION	 "201701270000Z"      -- January 27, 2017
    
    DESCRIPTION  "1) Added deviceSerialNumber under trapInformation
                  2) Added deviceSerialNumber to the OBJECTS clause of all traps
                 "



    REVISION	 "201501050000Z"      -- January 5, 2015
    
    DESCRIPTION  "1) Added agentInetPortNumber under trapInformation
                  2) Added agentInetPortNumber as a varbind to all traps
                 "



    REVISION	 "201307240000Z"      -- July 24, 2013
    
    DESCRIPTION  "SHX 30 support:
		  - add lhxVoltageLow, lhxBaseElectronicsFailure and
		    lhxCondenserPumpFailure traps
		  - add model and fwVersion to lhxConfigurationTable
		  - add sensorName to sensorConfigurationTable
		  - support valvePosition sensor type
		  - add sysContact, sysName, sysLocation to all traps"

    
    REVISION	 "201208130000Z"      -- August 13, 2012

    DESCRIPTION  "Extend LHX MIB:
    	    	  - add maximumCoolingState
		  - add alertState
		  - add defaultFanSpeed
		  - make defaultFanSpeed read-writable"

    REVISION	 "201105030000Z"      -- May 3, 2011

    DESCRIPTION  "The first version of the MIB."

		 ::= { enterprises 13742 }


lhxgw		OBJECT IDENTIFIER ::= { raritan 9 }

traps           OBJECT IDENTIFIER ::= { lhxgw 0 }
configuration   OBJECT IDENTIFIER ::= { lhxgw 1 }
measurements	OBJECT IDENTIFIER ::= { lhxgw 2 }
conformance     OBJECT IDENTIFIER ::= { lhxgw 3 }

lhx  	    	OBJECT IDENTIFIER ::= { configuration 3 }
gwSensors     	OBJECT IDENTIFIER ::= { configuration 4 }

trapInformation OBJECT IDENTIFIER ::= { traps 0 }

compliances     OBJECT IDENTIFIER ::= { conformance 1 }
groups          OBJECT IDENTIFIER ::= { conformance 2 }


-- Textual Conventions

OperationalStateEnumeration
	::= TEXTUAL-CONVENTION
	STATUS		current
	DESCRIPTION
	    "The operational states of an lhx controller."
	SYNTAX INTEGER {
		disconnected(0),
		offline(1),
		online(2)
	}

GwSensorTypeEnumeration
	::= TEXTUAL-CONVENTION
	STATUS		current
	DESCRIPTION
	    "The types an lhx sensor can be."
	SYNTAX INTEGER {
		airTemperature(0),
		waterTemperature(1),
		fanSpeed(2),
		doorContact(3),
		valvePosition(4)
	}

SensorUnitsEnumeration
	::= TEXTUAL-CONVENTION
	STATUS		current
	DESCRIPTION
	    "The units an lhx sensor can be."
	SYNTAX INTEGER {
		none(-1),
                other(0),
                volt(1),
                amp(2),
                watt(3),
                voltamp(4),
                wattHour(5),
                voltampHour(6),
                degreeC(7),
                hertz(8),
                percent(9),
                meterpersec(10),
                pascal(11),
                psi(12),
                g(13),
                degreeF(14),
                feet(15),
                inches(16),
                cm(17),
                meters(18),
		rpm(19)
	}
						
SensorStateEnumeration
	::= TEXTUAL-CONVENTION
	STATUS		current
	DESCRIPTION
	    "The states a sensor can be in."
	SYNTAX INTEGER {
                unavailable(-1),
                open(0),
                closed(1),
                belowLowerCritical(2),
                belowLowerWarning(3),
                normal(4),
                aboveUpperWarning(5),
                aboveUpperCritical(6),
                on(7),
                off(8),
                detected(9),
                notDetected(10),
                alarmed(11)
	}

-- the traps

lhxSensorFailure
    	NOTIFICATION-TYPE
    	OBJECTS {
		deviceName,
                sysContact,
                sysName,
                sysLocation,
    	    	deviceInetAddressType,
    	    	deviceInetIPAddress,
           agentInetPortNumber,
	    	lhxErrorCode,
    	    	portId,
    	    	probeId,
           deviceSerialNumber
    	}
    	STATUS	    	current
    	DESCRIPTION
    	    "A sensor failure (broken or short circuit) occurred."
    	::= { traps 1 }

lhxFanFailure
    	NOTIFICATION-TYPE
    	OBJECTS {
		deviceName,
                sysContact,
                sysName,
                sysLocation,
    	    	deviceInetAddressType,
    	    	deviceInetIPAddress,
           agentInetPortNumber,
	    	lhxErrorCode,
    	    	portId,
    	    	fanId,
           deviceSerialNumber
    	}
    	STATUS	    	current
    	DESCRIPTION
    	    "A fan motor failure occurred."
    	::= { traps 2 }

lhxPowerSupplyFailure
    	NOTIFICATION-TYPE
    	OBJECTS {
		deviceName,
                sysContact,
                sysName,
                sysLocation,
    	    	deviceInetAddressType,
    	    	deviceInetIPAddress,
           agentInetPortNumber,
	    	lhxErrorCode,
    	    	portId,
    	    	powerSupplyId,
           deviceSerialNumber
    	}
    	STATUS	    	current
    	DESCRIPTION
    	    "A power supply failure occurred."
    	::= { traps 3 }

lhxThresholdAirOutlet
    	NOTIFICATION-TYPE
    	OBJECTS {
		deviceName,
                sysContact,
                sysName,
                sysLocation,
    	    	deviceInetAddressType,
    	    	deviceInetIPAddress,
           agentInetPortNumber,
	    	lhxErrorCode,
    	    	portId,
           deviceSerialNumber
    	}
    	STATUS	    	current
    	DESCRIPTION
    	    "The air outlet temperature threshold was crossed."
    	::= { traps 4 }

lhxThresholdAirInlet
    	NOTIFICATION-TYPE
    	OBJECTS {
		deviceName,
                sysContact,
                sysName,
                sysLocation,
    	    	deviceInetAddressType,
    	    	deviceInetIPAddress,
           agentInetPortNumber,
	    	lhxErrorCode,
    	    	portId,
           deviceSerialNumber
    	}
    	STATUS	    	current
    	DESCRIPTION
    	    "The air inlet temperature threshold was crossed."
    	::= { traps 5 }

lhxThresholdWaterInlet
    	NOTIFICATION-TYPE
    	OBJECTS {
		deviceName,
                sysContact,
                sysName,
                sysLocation,
    	    	deviceInetAddressType,
    	    	deviceInetIPAddress,
           agentInetPortNumber,
	    	lhxErrorCode,
    	    	portId,
           deviceSerialNumber
    	}
    	STATUS	    	current
    	DESCRIPTION
    	    "The water inlet temperature threshold was crossed."
    	::= { traps 6 }

lhxDoorOpened
    	NOTIFICATION-TYPE
    	OBJECTS {
		deviceName,
                sysContact,
                sysName,
                sysLocation,
    	    	deviceInetAddressType,
    	    	deviceInetIPAddress,
           agentInetPortNumber,
	    	lhxErrorCode,
    	    	portId,
           deviceSerialNumber
    	}
    	STATUS	    	current
    	DESCRIPTION
    	    "The door was opened."
    	::= { traps 7 }

lhxMaximumCoolingRequest
    	NOTIFICATION-TYPE
    	OBJECTS {
		deviceName,
                sysContact,
                sysName,
                sysLocation,
    	    	deviceInetAddressType,
    	    	deviceInetIPAddress,
           agentInetPortNumber,
	    	lhxErrorCode,
    	    	portId,
           deviceSerialNumber
    	}
    	STATUS	    	current
    	DESCRIPTION
    	    "Maximum cooling was requested."
    	::= { traps 8 }

lhxEmergencyCooling
    	NOTIFICATION-TYPE
    	OBJECTS {
		deviceName,
                sysContact,
                sysName,
                sysLocation,
    	    	deviceInetAddressType,
    	    	deviceInetIPAddress,
           agentInetPortNumber,
	    	lhxErrorCode,
    	    	portId,
           deviceSerialNumber
    	}
    	STATUS	    	current
    	DESCRIPTION
    	    "Emergency cooling was activated."
    	::= { traps 9 }

lhxWaterLeak
    	NOTIFICATION-TYPE
    	OBJECTS {
		deviceName,
                sysContact,
                sysName,
                sysLocation,
    	    	deviceInetAddressType,
    	    	deviceInetIPAddress,
           agentInetPortNumber,
	    	lhxErrorCode,
    	    	portId,
           deviceSerialNumber
    	}
    	STATUS	    	current
    	DESCRIPTION
    	    "Water leakage was detected."
    	::= { traps 10 }

lhxThresholdHumidity
    	NOTIFICATION-TYPE
    	OBJECTS {
		deviceName,
                sysContact,
                sysName,
                sysLocation,
    	    	deviceInetAddressType,
    	    	deviceInetIPAddress,
           agentInetPortNumber,
	    	lhxErrorCode,
    	    	portId,
           deviceSerialNumber
    	}
    	STATUS	    	current
    	DESCRIPTION
    	    "The humidity threshold was crossed."
    	::= { traps 11 }

lhxExternalWaterCoolingFailure
    	NOTIFICATION-TYPE
    	OBJECTS {
		deviceName,
                sysContact,
                sysName,
                sysLocation,
    	    	deviceInetAddressType,
    	    	deviceInetIPAddress,
           agentInetPortNumber,
	    	lhxErrorCode,
    	    	portId,
           deviceSerialNumber
    	}
    	STATUS	    	current
    	DESCRIPTION
    	    "An external water cooling failure occurred."
    	::= { traps 12 }

lhxThresholdWaterOutlet
    	NOTIFICATION-TYPE
    	OBJECTS {
		deviceName,
                sysContact,
                sysName,
                sysLocation,
    	    	deviceInetAddressType,
    	    	deviceInetIPAddress,
           agentInetPortNumber,
	    	lhxErrorCode,
    	    	portId,
           deviceSerialNumber
    	}
    	STATUS	    	current
    	DESCRIPTION
    	    "The water outlet temperature threshold was crossed."
    	::= { traps 13 }

lhxParameterDataLoss
    	NOTIFICATION-TYPE
    	OBJECTS {
		deviceName,
                sysContact,
                sysName,
                sysLocation,
    	    	deviceInetAddressType,
    	    	deviceInetIPAddress,
           agentInetPortNumber,
	    	lhxErrorCode,
    	    	portId,
           deviceSerialNumber
    	}
    	STATUS	    	current
    	DESCRIPTION
    	    "Data loss in parameter memory was detected."
    	::= { traps 14 }

lhxStBusError
    	NOTIFICATION-TYPE
    	OBJECTS {
		deviceName,
                sysContact,
                sysName,
                sysLocation,
    	    	deviceInetAddressType,
    	    	deviceInetIPAddress,
           agentInetPortNumber,
	    	lhxErrorCode,
    	    	portId,
           deviceSerialNumber
    	}
    	STATUS	    	current
    	DESCRIPTION
    	    "An ST-Bus communication error was detected."
    	::= { traps 15 }
	
lhxCollectiveFault
    	NOTIFICATION-TYPE
    	OBJECTS {
		deviceName,
                sysContact,
                sysName,
                sysLocation,
    	    	deviceInetAddressType,
    	    	deviceInetIPAddress,
           agentInetPortNumber,
	    	lhxErrorCode,
    	    	portId,
           deviceSerialNumber
    	}
    	STATUS	    	current
    	DESCRIPTION
    	    "An error was detected."
    	::= { traps 16 }

gwSensorStateChange
    	NOTIFICATION-TYPE
        OBJECTS {
	    	deviceName,
                sysContact,
                sysName,
                sysLocation,
                deviceInetAddressType,
                deviceInetIPAddress,
                agentInetPortNumber,
		portId,
		sensorTypeId,
		sensorId,
    	    	probeId,
                measurementsSensorTimeStamp,
                measurementsSensorValue,
                measurementsSensorState,
                oldSensorState,
                deviceSerialNumber
	}
        STATUS	    	current
        DESCRIPTION
            "Sensor State Change."
        ::= { traps 17 }

gwLhxOperationalStateChange
    	NOTIFICATION-TYPE
        OBJECTS {
	    	deviceName,
                sysContact,
                sysName,
                sysLocation,
                deviceInetAddressType,
                deviceInetIPAddress,
                agentInetPortNumber,
		portId,
		operationalState,
                oldOperationalState,
           deviceSerialNumber
	}
        STATUS	    	current
        DESCRIPTION
            "Operational State Change."
        ::= { traps 18 }

lhxVoltageLow
	NOTIFICATION-TYPE
	OBJECTS {
		deviceName,
                sysContact,
                sysName,
                sysLocation,
		deviceInetAddressType,
		deviceInetIPAddress,
           agentInetPortNumber,
		lhxErrorCode,
		portId,
           deviceSerialNumber
	}
	STATUS		current
	DESCRIPTION
	    "The supply voltage of an LHX became low."
	::= { traps 19 }

lhxBaseElectronicsFailure
	NOTIFICATION-TYPE
	OBJECTS {
		deviceName,
                sysContact,
                sysName,
                sysLocation,
		deviceInetAddressType,
		deviceInetIPAddress,
           agentInetPortNumber,
		lhxErrorCode,
		portId,
           deviceSerialNumber
	}
	STATUS		current
	DESCRIPTION
	    "The base electronics of an LHX controller failed."
	::= { traps 20 }

lhxCondenserPumpFailure
	NOTIFICATION-TYPE
	OBJECTS {
		deviceName,
                sysContact,
                sysName,
                sysLocation,
		deviceInetAddressType,
		deviceInetIPAddress,
		lhxErrorCode,
           agentInetPortNumber,
		portId,
           deviceSerialNumber
	}
	STATUS		current
	DESCRIPTION
	    "An LHX condenser pump failed."
	::= { traps 21 }

-- the TrapInformation

deviceName
    	OBJECT-TYPE
    	SYNTAX	    	DisplayString
    	MAX-ACCESS  	accessible-for-notify
    	STATUS	    	current
    	DESCRIPTION
    	    "The user-defined name for the Device."
    	::= { trapInformation 1 }

deviceInetAddressType
    	OBJECT-TYPE
    	SYNTAX	    	InetAddressType
    	MAX-ACCESS  	accessible-for-notify
    	STATUS	    	current
    	DESCRIPTION
    	    "The type of address format"
    	::= { trapInformation 2 }

deviceInetIPAddress
    	OBJECT-TYPE
    	SYNTAX	    	InetAddress
    	MAX-ACCESS  	accessible-for-notify
    	STATUS	    	current
    	DESCRIPTION
    	    "The current IP address. A value of 0.0.0.0 indicates an
    	     error or an unset option."
    	::= { trapInformation 3 }

lhxErrorCode
    	OBJECT-TYPE
    	SYNTAX	    	DisplayString
    	MAX-ACCESS  	accessible-for-notify
    	STATUS	    	current
    	DESCRIPTION
    	    "The LHX error code (F1 -  F25, EP)."
    	::= { trapInformation 4 }

portId OBJECT-TYPE
    	SYNTAX        Integer32(1..256)
    	MAX-ACCESS    accessible-for-notify
    	STATUS        current
    	DESCRIPTION
    	    "A unique value for the physical port, the LHX controlller
	     is connected to.
	     Its value ranges between 1 and the value of portCount."
    	::= { trapInformation 5 }

probeId
    	OBJECT-TYPE
    	SYNTAX	    	DisplayString
    	MAX-ACCESS  	accessible-for-notify
    	STATUS	    	current
    	DESCRIPTION
    	    "The physical Sensor ID (F1 - F7)."
    	::= { trapInformation 6 }


fanId	OBJECT-TYPE
    	SYNTAX	    	DisplayString
    	MAX-ACCESS  	accessible-for-notify
    	STATUS	    	current
    	DESCRIPTION
    	    "The Fan ID (M1 - M6)."
    	::= { trapInformation 7 }


powerSupplyId
    	OBJECT-TYPE
    	SYNTAX	    	DisplayString
    	MAX-ACCESS  	accessible-for-notify
    	STATUS	    	current
    	DESCRIPTION
    	    "The Power Supply ID (1, 2)."
    	::= { trapInformation 8 }

oldSensorState
    	OBJECT-TYPE
        SYNTAX	    	SensorStateEnumeration
        MAX-ACCESS  	accessible-for-notify
        STATUS	    	current
        DESCRIPTION
            "The old sensor state used in Sensor State Transition traps."
        ::= { trapInformation 9 }

sensorTypeId
    	OBJECT-TYPE
        SYNTAX        GwSensorTypeEnumeration
        MAX-ACCESS    accessible-for-notify
        STATUS        current
        DESCRIPTION
            "A unique value for the type of sensor."
        ::= { trapInformation 10 }

sensorId
    	OBJECT-TYPE
        SYNTAX        Integer32(1..256)
        MAX-ACCESS    accessible-for-notify
        STATUS        current
        DESCRIPTION
            "A unique value for each sensor. Its value
             ranges between 1 and the value of sensorCount."
        ::= { trapInformation 11 }
	
oldOperationalState
    	OBJECT-TYPE
    	SYNTAX	    	OperationalStateEnumeration
    	MAX-ACCESS  	read-only
    	STATUS	    	current
    	DESCRIPTION
    	    "The old operational state used in Operational State Transition traps."
    	DEFVAL {0}
    	::= { trapInformation 12 }

agentInetPortNumber   OBJECT-TYPE
                      SYNTAX        InetPortNumber
                      MAX-ACCESS    accessible-for-notify
                      STATUS        current
                      DESCRIPTION
                          "The UDP port number used for accessing 
                              the SNMP agent on the device.
                              Examples: 
                                   If the associated device MIB (PX2-MIB, EMD-MIB) has deviceCascadeType set to portForwarding, then
                                       master: 50500
                                       slave 1:50501
                                       slave 2: 50502
                                       ...... 
                                   If cascading mode is not portForwarding and default (Standard) ports are being used, then
                                        port: 161
                                                       
                            "
         ::= { trapInformation 13  }  


deviceSerialNumber
    	OBJECT-TYPE
    	SYNTAX	    	DisplayString
    	MAX-ACCESS  	accessible-for-notify
    	STATUS	    	current
    	DESCRIPTION
    	    "The serial number of the Device."
    	::= { trapInformation 14 }

	
-- the LHX configuration

portCount
    	OBJECT-TYPE
    	SYNTAX	    	Integer32(1..255)
    	MAX-ACCESS  	read-only
    	STATUS	    	current
    	DESCRIPTION
    	    "The number of lhx units supported."
    	::= { configuration 1 }

sensorCountTable
    	OBJECT-TYPE
        SYNTAX	    	SEQUENCE OF SensorCountEntryStruct
        MAX-ACCESS  	not-accessible
        STATUS	    	current
        DESCRIPTION
            "A list of lhx sensor count extries."
        ::= { configuration 2 }

sensorCountEntry
    	OBJECT-TYPE
        SYNTAX	    	SensorCountEntryStruct
        MAX-ACCESS  	not-accessible
        STATUS	    	current
        DESCRIPTION
            "An entry containing the number of lhx sensors of a certain type."
        INDEX	    	{ portIdx, sensorTypeIdx }
        ::= { sensorCountTable 1 }

SensorCountEntryStruct
    	::= SEQUENCE {
		sensorCount Integer32
    	}

sensorCount
    	OBJECT-TYPE
    	SYNTAX	    	Integer32
    	MAX-ACCESS  	read-only
    	STATUS	    	current
    	DESCRIPTION
    	    "The number of sensors."
    	::= { sensorCountEntry 1 }

-- lhx centric configuration

lhxConfigurationTable
    	OBJECT-TYPE
        SYNTAX	    	SEQUENCE OF LhxConfigurationEntryStruct
        MAX-ACCESS  	not-accessible
        STATUS	    	current
        DESCRIPTION
            "A list of lhx controller configuration extries.
             The number of entries is given by the value of portCount."
        ::= { lhx 1 }

lhxConfigurationEntry
    	OBJECT-TYPE
        SYNTAX	    	LhxConfigurationEntryStruct
        MAX-ACCESS  	not-accessible
        STATUS	    	current
        DESCRIPTION
            "An entry containing parameters for an lhx."
        INDEX	    	{ portIdx }
        ::= { lhxConfigurationTable 1 }

LhxConfigurationEntryStruct
    	::= SEQUENCE {
	    	operationalState    OperationalStateEnumeration,
		setpointVentilators Integer32,
		setpointWaterValve  Integer32,
		defaultFanSpeed     Integer32,
		maximumCoolingState TruthValue,
		alertState  	    TruthValue,
		model	    	    DisplayString,
		fwVersion   	    DisplayString
    	}

operationalState
    	OBJECT-TYPE
    	SYNTAX	    	OperationalStateEnumeration
    	MAX-ACCESS  	read-write
    	STATUS	    	current
    	DESCRIPTION
    	    "The operational state of the lhx controller.
	     To switch LHX power state while controller is connected,
	     set operationalState to 1 (off) or 2 (on).
	     Switching power state while LHX is disconnected or to 
	     0 (disconnected) is undefined."
    	DEFVAL {0}
    	::= { lhxConfigurationEntry 1 }

setpointVentilators
    	OBJECT-TYPE
    	SYNTAX	    	Integer32
    	MAX-ACCESS  	read-write
    	STATUS	    	current
    	DESCRIPTION
    	    "The setpoint of the ventilators."
    	DEFVAL {0}
    	::= { lhxConfigurationEntry 2 }

setpointWaterValve
    	OBJECT-TYPE
    	SYNTAX	    	Integer32
    	MAX-ACCESS  	read-write
    	STATUS	    	current
    	DESCRIPTION
    	    "The setpoint of the water valve."
    	DEFVAL {0}
    	::= { lhxConfigurationEntry 3 }

defaultFanSpeed
    	OBJECT-TYPE
    	SYNTAX	    	Integer32
    	MAX-ACCESS  	read-write
    	STATUS	    	current
    	DESCRIPTION
    	    "The 'default' fan speed during normal operation in per mill.
	     Default is 80% (= 800)."
    	DEFVAL {0}
    	::= { lhxConfigurationEntry 4 }

maximumCoolingState
    	OBJECT-TYPE
	SYNTAX	    	TruthValue
    	MAX-ACCESS  	read-write
    	STATUS	    	current
    	DESCRIPTION
    	    "Indicates whether maximum cooling was requested or not.
	     To request maximum cooling, set maximumCoolingState to 1 (true).
	     Setting maximumCoolingState to 2 (false) is undefined,
	     set alertState to 2 (false) instead."
    	DEFVAL {2}
    	::= { lhxConfigurationEntry 5 }

alertState
    	OBJECT-TYPE
	SYNTAX	    	TruthValue
    	MAX-ACCESS  	read-write
    	STATUS	    	current
    	DESCRIPTION
    	    "Indicates whether LHX controler is in alert state or not.
	     To acknowledge alert status, set alertState to 2 (false).
	     Setting alertState to 1 (true) is undefined."
    	DEFVAL {2}
    	::= { lhxConfigurationEntry 6 }

model
	OBJECT-TYPE
	SYNTAX	    	DisplayString
	MAX-ACCESS	read-only
	STATUS		current
	DESCRIPTION
	    "The model indentifier of an LHX controller."
	::= { lhxConfigurationEntry 7 }

fwVersion
	OBJECT-TYPE
	SYNTAX	    	DisplayString
	MAX-ACCESS	read-only
	STATUS		current
	DESCRIPTION
	    "The firmware version of an LHX controller."
	::= { lhxConfigurationEntry 8 }

-- sensor centric configuration

sensorConfigurationTable
    	OBJECT-TYPE
        SYNTAX	    	SEQUENCE OF SensorConfigurationEntryStruct
        MAX-ACCESS  	not-accessible
        STATUS	    	current
        DESCRIPTION
            "A list of lhx sensor configuration extries.
             The number of entries is given by the value of portCount."
        ::= { gwSensors 1 }

sensorConfigurationEntry
    	OBJECT-TYPE
	SYNTAX	    	SensorConfigurationEntryStruct
	MAX-ACCESS  	not-accessible
	STATUS	    	current
	DESCRIPTION
            "An entry containing parameters for an lhx."
	INDEX         { portIdx, sensorTypeIdx, sensorIdx }
	::= { sensorConfigurationTable 1 }

SensorConfigurationEntryStruct
    	::= SEQUENCE {
	    	portIdx     	    	    	Integer32,
        	sensorTypeIdx    	    	Integer32,
		sensorIdx   	    	    	Integer32,
        	sensorLabel                 	DisplayString,
        	sensorUnit  	    	    	SensorUnitsEnumeration,
        	sensorDecimalDigits             Unsigned32,
        	sensorMaximum                   Integer32,
        	sensorMinimum                   Integer32,
        	sensorHysteresis                Unsigned32,
        	sensorLowerCriticalThreshold    Integer32,
        	sensorLowerWarningThreshold     Integer32,
        	sensorUpperCriticalThreshold	Integer32,
        	sensorUpperWarningThreshold     Integer32,
        	sensorEnabledThresholds         BITS,
        	sensorThresholdMaximum          Integer32,
	sensorThresholdMinimum          Integer32,
		sensorName  	    	    	DisplayString
        }

portIdx
    	OBJECT-TYPE
        SYNTAX        Integer32(1..256)
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
            "A unique value for each port. Its value
             ranges between 1 and the value of portCount."
        ::= { sensorConfigurationEntry 1 }

sensorTypeIdx
    	OBJECT-TYPE
        SYNTAX        Integer32(0..255)
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
            "A unique value for the type of sensor."
        ::= { sensorConfigurationEntry 2 }

sensorIdx
    	OBJECT-TYPE
        SYNTAX        Integer32(1..256)
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
            "A unique value for each sensor. Its value
             ranges between 1 and the value of sensorCount."
        ::= { sensorConfigurationEntry 3 }

sensorLabel
    	OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The short ID of the sensor (e.g. F1, M2)."
        ::= { sensorConfigurationEntry 4 }

sensorUnit
    	OBJECT-TYPE
        SYNTAX        SensorUnitsEnumeration
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The base units.
             This parameter does not apply to state sensors."
        ::= { sensorConfigurationEntry 5 }

sensorDecimalDigits
    	OBJECT-TYPE
        SYNTAX        Unsigned32
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The number of digits displayed to the right of the decimal point.
             This parameter does not apply to state sensors."
        ::= { sensorConfigurationEntry 6 }

sensorMaximum
    	OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The largest possible value.
             The value of this OID variable should be scaled by
             sensorDecimalDigits.  For example, if the value is 1 and
             sensorDecimalDigits is 2, then actual value is 0.01.
             This parameter does not apply to state sensors."
        ::= { sensorConfigurationEntry 7 }

sensorMinimum
    	OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The smallest possible value.
             The value of this OID variable should be scaled by
             sensorDecimalDigits.  For example, if the value is 1 and
             sensorDecimalDigits is 2, then actual value is 0.01.
             This parameter does not apply to state sensors."
        ::= { sensorConfigurationEntry 8 }

sensorHysteresis
    	OBJECT-TYPE
        SYNTAX        Unsigned32
        MAX-ACCESS    read-write
        STATUS        current
        DESCRIPTION
            "The hysteresis used for deassertions.
             The value of this OID variable should be scaled by
             sensorDecimalDigits.  For example, if the value is 1 and
             sensorDecimalDigits is 2, then actual value is 0.01.
             This parameter does not apply to state sensors."
        ::= { sensorConfigurationEntry 9 }

sensorLowerCriticalThreshold
    	OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-write
        STATUS        current
        DESCRIPTION
            "The lower critical threshold.
             The value of this OID variable should be scaled by
             sensorDecimalDigits.  For example, if the value is 1 and
             sensorDecimalDigits is 2, then actual value is 0.01.
             This parameter does not apply to state sensors."
        ::= { sensorConfigurationEntry 10 }

sensorLowerWarningThreshold
    	OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-write
        STATUS        current
        DESCRIPTION
            "The lower non-critical (warning) threshold.
             The value of this OID variable should be scaled by
             sensorDecimalDigits.  For example, if the value is 1 and
             sensorDecimalDigits is 2, then actual value is 0.01.
             This parameter does not apply to state sensors."
        ::= { sensorConfigurationEntry 11 }

sensorUpperCriticalThreshold
    	OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-write
        STATUS        current
        DESCRIPTION
            "The upper critical  threshold.
             The value of this OID variable should be scaled by
             sensorDecimalDigits.  For example, if the value is 1 and
             sensorDecimalDigits is 2, then actual value is 0.01.
             This parameter does not apply to state sensors."
        ::= { sensorConfigurationEntry 12 }

sensorUpperWarningThreshold
    	OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-write
        STATUS        current
        DESCRIPTION
            "The upper non-critical (warning) threshold.
             The value of this OID variable should be scaled by
             sensorDecimalDigits.  For example, if the value is 1 and
             sensorDecimalDigits is 2, then actual value is 0.01.
             This parameter does not apply to state sensors."
        ::= { sensorConfigurationEntry 13 }

sensorEnabledThresholds
    	OBJECT-TYPE
        SYNTAX BITS {
    	    	lowerCritical(0),
                lowerWarning(1),
                upperWarning(2),
                upperCritical(3)
    	}
        MAX-ACCESS    read-write
        STATUS        current
        DESCRIPTION
            "A bit string which indicates which thresholds are enabled.
             This parameter does not apply to state sensors."
        ::= { sensorConfigurationEntry 14 }

sensorThresholdMaximum
    	OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The largest possible threshold value.
             The value of this OID variable should be scaled by
             sensorDecimalDigits.  For example, if the value is 1 and
             sensorDecimalDigits is 2, then actual value is 0.01.
             This parameter does not apply to state sensors."
        ::= { sensorConfigurationEntry 15 }

sensorThresholdMinimum
    	OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The smallest possible threshold value.
             The value of this OID variable should be scaled by
             sensorDecimalDigits.  For example, if the value is 1 and
             sensorDecimalDigits is 2, then actual value is 0.01.
             This parameter does not apply to state sensors."
        ::= { sensorConfigurationEntry 16 }

sensorName
	OBJECT-TYPE
        SYNTAX        DisplayString
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The descriptive ID of the sensor (e.g. Fan Speed 1)."
        ::= { sensorConfigurationEntry 17 }

-- the Sensor Measurements table

sensorMeasurementsTable
    	OBJECT-TYPE
    	SYNTAX        SEQUENCE OF SensorMeasurementsEntryStruct
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
            "A list of external sensor entries. The number of
             entries is given by the value of sensorCount
             for the LHX."
        ::= { measurements 1 }

sensorMeasurementsEntry
    	OBJECT-TYPE
    	SYNTAX        SensorMeasurementsEntryStruct
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
            "An entry containing measurement objects for an external sensor."
        INDEX         { portIdx, sensorTypeIdx, sensorIdx }
        ::= { sensorMeasurementsTable 1 }

SensorMeasurementsEntryStruct
    	::= SEQUENCE {
    	    	measurementsSensorIsAvailable	TruthValue,
        	measurementsSensorState     	SensorStateEnumeration,
        	measurementsSensorValue     	Integer32,
        	measurementsSensorTimeStamp 	Unsigned32
    	}

measurementsSensorIsAvailable
    	OBJECT-TYPE
        SYNTAX        TruthValue
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "Is the sensor available?"
        ::= { sensorMeasurementsEntry 1 }

measurementsSensorState
    	OBJECT-TYPE
        SYNTAX        SensorStateEnumeration
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The sensor state."
        ::= { sensorMeasurementsEntry 2 }

measurementsSensorValue
    	OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The sensor reading.
             This parameter does not apply to state sensors."
        ::= { sensorMeasurementsEntry 3 }

measurementsSensorTimeStamp
    	OBJECT-TYPE
        SYNTAX        Unsigned32
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "The sensor reading timestamp."
        ::= { sensorMeasurementsEntry 4 }
	
-- Conformance Information
-- compliance statements

complianceRev1
    	MODULE-COMPLIANCE
        STATUS	    	current
        DESCRIPTION
            "The requirements for conformance to the LHX-MIB."
        MODULE -- this module

        GROUP configurationGroup
        DESCRIPTION
            "The configuration group."

        GROUP measurementsGroup
        DESCRIPTION
            "The measurements group."

        GROUP trapInformationGroup
        DESCRIPTION
            "The information group."

        GROUP trapsGroup
        DESCRIPTION
            "The traps group."

        ::= { compliances 1 }

-- units of conformance

configurationGroup
    	OBJECT-GROUP
        OBJECTS {
		portCount,
    	    	portId,
		operationalState,
		sensorCount,
        	sensorLabel,
        	sensorUnit,
        	sensorDecimalDigits,
        	sensorMaximum,
        	sensorMinimum,
        	sensorHysteresis,
        	sensorLowerCriticalThreshold,
        	sensorLowerWarningThreshold,
        	sensorUpperCriticalThreshold,
        	sensorUpperWarningThreshold,
        	sensorEnabledThresholds,
		setpointVentilators,
		setpointWaterValve,
		defaultFanSpeed,
		maximumCoolingState,
		alertState,
		sensorThresholdMaximum,
		sensorThresholdMinimum,
		model,
		fwVersion,
		sensorName
    	}
        STATUS	    	current
        DESCRIPTION
            "A collection of objects representing configuration data."
        ::= { groups 1 }

measurementsGroup
    	OBJECT-GROUP
        OBJECTS {
    	    	measurementsSensorIsAvailable, 	
    	    	measurementsSensorState,	
    	    	measurementsSensorValue,	
    	    	measurementsSensorTimeStamp	
    	}
        STATUS	    	current
        DESCRIPTION
            "A collection of objects providing the measurement
             capability of LHX."
        ::= { groups 2 }

trapInformationGroup
    	OBJECT-GROUP
        OBJECTS {
		deviceName,
    	    	deviceInetAddressType,
    	    	deviceInetIPAddress,
	    	lhxErrorCode,
		portId,
    	    	probeId,
		fanId,
		powerSupplyId,
    	    	oldSensorState,
		sensorTypeId,
		sensorId,
		oldOperationalState,
           agentInetPortNumber,
           deviceSerialNumber
    	}
        STATUS	    	current
        DESCRIPTION
            "A collection of objects providing
             information in the traps."
        ::= { groups 3 }

trapsGroup
    	NOTIFICATION-GROUP
        NOTIFICATIONS {
		lhxSensorFailure,
		lhxFanFailure,
		lhxPowerSupplyFailure,
		lhxThresholdAirOutlet,
		lhxThresholdAirInlet,
		lhxThresholdWaterInlet,
		lhxDoorOpened,
		lhxMaximumCoolingRequest,
		lhxEmergencyCooling,
		lhxWaterLeak,
		lhxThresholdHumidity,
		lhxExternalWaterCoolingFailure,
		lhxThresholdWaterOutlet,
		lhxParameterDataLoss,
		lhxStBusError,
		lhxCondenserPumpFailure,
		gwSensorStateChange,
		gwLhxOperationalStateChange,
		lhxCollectiveFault,
		lhxVoltageLow,
		lhxBaseElectronicsFailure
    	}
        STATUS	    	current
        DESCRIPTION
                "A collection of traps."
        ::= { groups 4 }