-- MibName=raisecomKeepaliveToSNMPManagerGroup
-- =======================================================================
-- Version info 
--
-- Version 0.1 Created 2007.07.09 by LIAOBIN
-- Copyright(c) 2003-2007 by RAISECOM TECH, Ltd. 
-- =======================================================================

-- ===========================================================================

--
-- RAISECOM keepalive management objects
--            

RAISECOM-KEEPALIVE-MIB DEFINITIONS ::= BEGIN

    IMPORTS
		MODULE-IDENTITY,
		OBJECT-TYPE,
		NOTIFICATION-TYPE ,
		Integer32,
		IpAddress,
		Counter32,
		Unsigned32
			FROM SNMPv2-SMI
		DisplayString,
		TimeStamp,
		RowStatus,
		TruthValue
			FROM SNMPv2-TC    
		DateAndTime,
		EnableVar
			FROM SWITCH-TC       
		raisecomAgent		
			FROM RAISECOM-BASE-MIB
			
		rcL3IpSubnetIfIndex,rcL3IpSubnetIpAddress,rcL3IpSubnetMask	
         FROM SWITCH-L3-MIB           		
    sysName,sysObjectID           	
         FROM RFC1213-MIB  		        
    rcSwitchMacAddress,rcSwitchRoseVersion, rcSwitchHardwareVersion	
         FROM SWITCH-SYSTEM-MIB  		         
          
		raisecomCommonManagement
			FROM RAISECOM-COMMON-MANAGEMENT-MIB;

	raisecomKeepaliveToSNMPManagerGroup    MODULE-IDENTITY
		LAST-UPDATED 	"200707090000Z"
		ORGANIZATION 	"RAISECOM TECH, Ltd."
		CONTACT-INFO 	"www.raisecom.com"
		DESCRIPTION  	
		    "The MIB module defining objects for SNMP keepalive functions"
		::= { raisecomCommonManagement  6}  
              	
-- raisecomKeepaliveToSNMPManagerGroup   
    
 	raisecomKeepaliveMibObjects OBJECT IDENTIFIER ::= { raisecomKeepaliveToSNMPManagerGroup 1 }
	raisecomKeepaliveTraps   OBJECT IDENTIFIER ::= { raisecomKeepaliveToSNMPManagerGroup 2 }

	raisecomKeepaliveTrapEnable  OBJECT-TYPE
  	SYNTAX          INTEGER{
        			enable(1),
        			disable(2),
        			pause(3)
        			}
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
            "Indicates whether keepalive traps should be generated periodically.Disable 
            and pause indicate keepalive traps should not be generated.If the value of 
            this object is disable,it allow to be config loaded.If user makes this object 
            disable and saves config,keepalive trap will not be generated after load 
            config.If this object is pause,it don't allow to be config loaded."    
        DEFVAL	{ enable }
    	::= { raisecomKeepaliveMibObjects 1 }


	raisecomKeepaliveTrapInterval  OBJECT-TYPE
        SYNTAX        INTEGER (120 .. 28800) 
        UNITS         "seconds"
        MAX-ACCESS    read-write
        STATUS        current
        DESCRIPTION   "The value of this object indicates number of 
                       seconds between the transmission of keepalive  
                       trap."                       
        DEFVAL { 300 }
        ::= { raisecomKeepaliveMibObjects 2 }
        
  raisecomKeepaliveTrapCounter  OBJECT-TYPE
        SYNTAX        Counter32 
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION   "The value of this object indicates number of 
                       keepalive trap have sent."                       
        ::= { raisecomKeepaliveMibObjects 3}
	
   raisecomKeepalive NOTIFICATION-TYPE
           OBJECTS {rcL3IpSubnetIfIndex,rcL3IpSubnetIpAddress,rcL3IpSubnetMask,sysName,sysObjectID, 
           rcSwitchMacAddress,rcSwitchRoseVersion, rcSwitchHardwareVersion}
           STATUS  current
           DESCRIPTION
               "notify snmp manager that rcL3IpSubnetIp and other information periodically."
       ::= { raisecomKeepaliveTraps 1 }
       
END