RAD-Mpmx-MIB DEFINITIONS ::= BEGIN

-- It is RAD's intent to encourage the widespread use of
-- this Specification in connection with the management of
-- RAD products. RAD grants vendors, end-users,
-- and other interested parties a non-exclusive license to
-- use this Specification in connection with the management
-- of RAD products.

-- This Specification is supplied "as is," and RAD makes
-- no warranty, either express or implied, as to the use,
-- operation, condition, or performance of the Specification.


IMPORTS

       ifAlias, ifIndex     FROM  IF-MIB
       SnmpAdminString     FROM  SNMP-FRAMEWORK-MIB
       Integer32, Counter32, IpAddress, 
       Unsigned32, OBJECT-TYPE, MODULE-IDENTITY, 
       NOTIFICATION-TYPE, OBJECT-IDENTITY     FROM  SNMPv2-SMI
       DisplayString, RowStatus, TruthValue     FROM  SNMPv2-TC
       radWan, wanGen     FROM  RAD-SMI-MIB
       agnLed, alarmEventLogSourceName, alarmEventLogAlarmOrEventId, 
       alarmEventLogDescription, alarmEventLogSeverity, alarmEventLogDateAndTime, 
       alarmEventReason     FROM  RAD-GEN-MIB
       CardType, ProtectLastSwitchReasonType     FROM  RAD-TC; 


    chasWanGen  MODULE-IDENTITY
        LAST-UPDATED "201609182024Z"  -- September 18, 2016
        ORGANIZATION "RAD Data Communications Ltd."
        CONTACT-INFO
        "System Department
     
         Email:  mibs@rad.com    
         Postal: RAD Data Communications Ltd.
                 24 Raoul Wallenberg St.
                 Tel-Aviv 6971920
                 Israel

         Phone:  +972-3-645-5421
         Fax:    +972-3-760-7844"
         DESCRIPTION
            "Megaplex Maccess MIB." 
    ::= { wanGen 1 }

    
muxHub OBJECT IDENTIFIER ::= {radWan 2}

--  ----------------------------------------------------------------------------------------------
-- chasWanGen  OBJECT IDENTIFIER ::= {wanGen 1}
agnWanGen       OBJECT IDENTIFIER ::= {wanGen 2}
mdlWanGen       OBJECT IDENTIFIER ::= {wanGen 3}
prtWanGen       OBJECT IDENTIFIER ::= {wanGen 4}
mapWanGen       OBJECT IDENTIFIER ::= {wanGen 5}
diverseIfWanGen OBJECT IDENTIFIER ::= {wanGen 6}
--diverseIfWanGen OBJECT IDENTIFIER ::= {wanGen 6}	defined  RAD-Diverse-IF-MIB

--ethIf          OBJECT IDENTIFIER ::= {diverseIfWanGen 1} (see ethif.txt)
--sonetInterface OBJECT IDENTIFIER ::= {diverseIfWanGen 2} (see radsonet.txt)
--ds3Interface	 OBJECT IDENTIFIER ::= {diverseIfWanGen 3} (see radds3.txt)
--ds1Interface	 OBJECT IDENTIFIER ::= {diverseIfWanGen 4} (see radds1.txt)
--hdlcMibObjects OBJECT IDENTIFIER ::= {diverseIfWanGen 5} (see radhdlc.txt)
--v51If          OBJECT IDENTIFIER ::= {diverseIfWanGen 6} (see v51.txt)
--ip2If          OBJECT IDENTIFIER ::= {diverseIfWanGen 7} (see ipmux.txt)
--broadbandIf    OBJECT IDENTIFIER ::= {diverseIfWanGen 8} (see bdband.txt)
--r2If           OBJECT IDENTIFIER ::= {diverseIfWanGen 9} (see r2.txt)
--adslIf		 OBJECT IDENTIFIER ::= {diverseIfWanGen 10} (see radadsl.txt)
--sdslIf		 OBJECT IDENTIFIER ::= {diverseIfWanGen 11} (see radsdsl.txt)
--shdslIf		 OBJECT IDENTIFIER ::= {diverseIfWanGen 12} (see radshdsl.txt)
--voiceIf		 OBJECT IDENTIFIER ::= {diverseIfWanGen 13} (see voiceIf.txt)
--gsmInterface	 OBJECT IDENTIFIER ::= {diverseIfWanGen 14} (see radGsm.txt)
--ds0BundleIf	 OBJECT IDENTIFIER ::= {diverseIfWanGen 15} (see radds0.txt)
--pdhInterface	 OBJECT IDENTIFIER ::= {diverseIfWanGen 16} (see radpdh.txt)

--voipWanGen OBJECT IDENTIFIER ::= {wanGen 7} (see voip.txt)


statAgnGen          OBJECT IDENTIFIER ::= {agnWanGen 1}
cnfgAgnGen          OBJECT IDENTIFIER ::= {agnWanGen 2}
cmprAgnGen          OBJECT IDENTIFIER ::= {agnWanGen 3}
alrBuffGen          OBJECT IDENTIFIER ::= {agnWanGen 4}
agnFlipDb           OBJECT IDENTIFIER ::= {agnWanGen 5}
agnSa               OBJECT IDENTIFIER ::= {agnWanGen 6}
agnListDecoding     OBJECT IDENTIFIER ::= {agnWanGen 7}
agnSystemDlci       OBJECT IDENTIFIER ::= {agnWanGen 8}
agnVoiceSwitching   OBJECT IDENTIFIER ::= {agnWanGen 9}
agnSigProfile       OBJECT IDENTIFIER ::= {agnWanGen 10}
agnSystemTs         OBJECT IDENTIFIER ::= {agnWanGen 11}
systemVoice         OBJECT IDENTIFIER ::= {agnWanGen 12}

statMdlGen      OBJECT IDENTIFIER ::= {mdlWanGen 1}
cnfgMdlGen      OBJECT IDENTIFIER ::= {mdlWanGen 2}
cmprMdlGen      OBJECT IDENTIFIER ::= {mdlWanGen 3}


statPrtGen      OBJECT IDENTIFIER ::= {prtWanGen 1}
cnfgPrtGen      OBJECT IDENTIFIER ::= {prtWanGen 2}
cmprPrtGen      OBJECT IDENTIFIER ::= {prtWanGen 3}

--statisPrtGen   OBJECT IDENTIFIER ::= {statPrtGen 3} - Statistics of Ports
--prtFrStatis    OBJECT IDENTIFIER ::= {statisPrtGen 1}
--prtCrStatis    OBJECT IDENTIFIER ::= {statisPrtGen 2}
--prtDlciStatis  OBJECT IDENTIFIER ::= {statisPrtGen 3}
--prtT1Statis    OBJECT IDENTIFIER ::= {statisPrtGen 4}

agnMux        OBJECT IDENTIFIER ::= {muxHub 1}
mdlMux        OBJECT IDENTIFIER ::= {muxHub 2}
prtMux          OBJECT IDENTIFIER ::= {muxHub 3}

--cnfgMdlMux         OBJECT IDENTIFIER ::= {mdlMux 1}
--statMdlMux         OBJECT IDENTIFIER ::= {mdlMux 2}

statPrtMux         OBJECT IDENTIFIER ::= {prtMux 1}
cnfgPrtMux      OBJECT IDENTIFIER ::= {prtMux 2}

statisPrtGen    OBJECT IDENTIFIER ::= {statPrtGen 3}

prtFrStatis     OBJECT IDENTIFIER ::= {statisPrtGen 1}
prtCrStatis     OBJECT IDENTIFIER ::= {statisPrtGen 2}
prtDlciStatis   OBJECT IDENTIFIER ::= {statisPrtGen 3}
prtT1Statis     OBJECT IDENTIFIER ::= {statisPrtGen 4}

--

--prtSExHsfStatTable   OBJECT IDENTIFIER ::= {statPrtMux 6}
--prtIsdnStatusTable   OBJECT IDENTIFIER ::= {statPrtMux 16}

--

prtClCnfg       OBJECT IDENTIFIER ::= {cnfgPrtMux 1}
prtPh1MlCnfg    OBJECT IDENTIFIER ::= {cnfgPrtMux 2} --MPH1/e1/t1
prtPhPlCnfg     OBJECT IDENTIFIER ::= {cnfgPrtMux 3} --MPH1,MPH3,MPL6
prtLs2Cnfg      OBJECT IDENTIFIER ::= {cnfgPrtMux 4} --LS2 family
--prtVc2CnfgTable      OBJECT IDENTIFIER ::= {cnfgPrtMux 5}
--prtHsfCnfgTable      OBJECT IDENTIFIER ::= {cnfgPrtMux 6}
prtHs4Cnfg      OBJECT IDENTIFIER ::= {cnfgPrtMux 7}
prtHsiCnfg      OBJECT IDENTIFIER ::= {cnfgPrtMux 8}
prtPVc4Cnfg     OBJECT IDENTIFIER ::= {cnfgPrtMux 9}
prtHsrCnfg      OBJECT IDENTIFIER ::= {cnfgPrtMux 10}
prtMbeCnfg      OBJECT IDENTIFIER ::= {cnfgPrtMux 11}
prtTreCnfg      OBJECT IDENTIFIER ::= {cnfgPrtMux 12}
prtLs6Cnfg      OBJECT IDENTIFIER ::= {cnfgPrtMux 13}
prtVc3Cnfg      OBJECT IDENTIFIER ::= {cnfgPrtMux 14}
prtVcPbxCnfg    OBJECT IDENTIFIER ::= {cnfgPrtMux 15}
prtIsdnCnfg     OBJECT IDENTIFIER ::= {cnfgPrtMux 16}
prtLogicalCnfg  OBJECT IDENTIFIER ::= {cnfgPrtMux 17}
prtFrPlusCnfg   OBJECT IDENTIFIER ::= {cnfgPrtMux 18}
prtMl4Cnfg      OBJECT IDENTIFIER ::= {cnfgPrtMux 19}
prtAcmCnfg      OBJECT IDENTIFIER ::= {cnfgPrtMux 20}
prtE2Cnfg       OBJECT IDENTIFIER ::= {cnfgPrtMux 21}
prtLanWanCnfg   OBJECT IDENTIFIER ::= {cnfgPrtMux 22}

--
-- Wan chassis general information
--

chasVersion OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..255))
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "An ASCII string for description and display of the agent chassis version."
      ::= { chasWanGen 1 }

chasTotalNoOfSlt  OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This entry indicates the number of physical slots in the
       chassis."
      ::= { chasWanGen 2 }

chasTotalNoOfIoSlt  OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This entry indicates the total number of physical IO slots
       in the chassis, (not all slots hardware should be occupied
       and active) ."
      ::= { chasWanGen 3 }

chasTotalNoOfPsSlt  OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This entry indicates the number of physical Power Supply
       slots in the chassis."
      ::= { chasWanGen 4 }

chasTotalNoOfClSlt  OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This entry indicates the number of physical Common Logic slots in the
       chassis."
      ::= { chasWanGen 5 }

--
-- Wan agent status general information
--
agnSDateFormat  OBJECT-TYPE
      SYNTAX  INTEGER
       {
          ddMMYYYY (1),
          mmDDYYYY (2),
          yyyyDDMM (3),
		  yyyyMMDD (4)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This entry indicates the date and time format used for the
       agnSDateAndTimeCmd and for the alarm history report."
      ::= { statAgnGen 1 }

agnSDateCmd  OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..255))
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This entry indicates the current date as it is known by the
       agent using its own real-time clock. The format would be as
       specified by the agnSDateFormat.
       This  parameter can be set for time synchronization between
       the NMS and the Agent."
      ::= { statAgnGen 2 }

agnSTimeCmd  OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..255))
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This entry indicates the current time as it is known by the
       agent using its own real-time clock.
       This  parameter can be set for time synchronization between
       the NMS and the Agent."
      ::= { statAgnGen 3 }

agnSActiveCnfg  OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This entry specifies the unique identifier of the  configuration,
       that is currently  active and running."
      ::= { statAgnGen 4 }
-- return 1 (db1) in phase I

agnSEditCnfg OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This entry indicates the  unique identifier of the
       configuration that is currently loaded into the tmp working
       space  for manipulation and update operations. Value of 255
       means no config. is under editing process."
      ::= { statAgnGen 5 }
-- return 1 (db1) in phase I

agnSLastCnfgFlipTime OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..255))
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This entry indicates the Date & Time of the last flip to the
       current configuration at the agent."
      ::= { statAgnGen 6 }
-- return sysUpTime in phase I

agnSLastCnfgFlipCause OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..255))
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This entry describes the flip's cause."
      ::= { statAgnGen 7 }
-- In phase I return two causes:
--          Power up
--          Update Db

agnSEditBy OBJECT-TYPE
      SYNTAX  INTEGER
       {
           none            (1),
           snmp            (2),
           terCon1         (3),
           terCon2         (4),
           terInbandCon1   (5),
           terInbandCon2   (6),
           lcd             (7)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This entry indicates which MMI application is working on  the
       edited config.
       The editing phase starts at the first modify operation and
       ends after an update(load) operation."
      ::= { statAgnGen 8 }

agnSClkSrc  OBJECT-TYPE
      SYNTAX  INTEGER
    {
        master  (1),
        fallback(2),
        internal(3)
 }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
     "This entry indicates the source of the system clock."
      ::= { statAgnGen 9 }

agnSAlrStatus OBJECT-TYPE
      SYNTAX  INTEGER
       {
  off      (2),
  event    (3),
  minor    (4),
  major    (5),
  warning  (6),
  critical (7)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Indicates the alarm state in the agent level, i.e. lower
       level (card/port) alarms not included.
    critical(7) - when there is at least one active (state ON)
                  critical alarm,
                  otherwise it will be set to
       major(5) - when there is at least one active (state ON)
                  major alarm,
                  otherwise it will be set to
       minor(4) - if there is at least one active (state ON) minor
                  alarm,
                  otherwise it will be set to
       warning(6) - if there is at least one active (state ON)
                  warning alarm,
                  otherwise it will be set to
       event(3) - if there was at least one alarm event (including
                  state on,off events) since the last clear operation."
      ::= { statAgnGen 10 }

agnSAlrStatusAll OBJECT-TYPE
      SYNTAX  INTEGER
       {
  off      (2),
  event    (3),
  minor    (4),
  major    (5),
     warning  (6),
  critical (7)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Indicates the alarm state of the entire agent, i.e.
       including card and port alarms status.
    critical(7) - when there is at least one active (state ON)
                  critical alarm,
                  otherwise it will be set to
       major(5) - when there is at least one active (state ON)
                  major alarm,
                  otherwise it will be set to
       minor(4) - if there is at least one active (state ON) minor
                  alarm,
                  otherwise it will be set to
       warning(6) - if there is at least one active (state ON)
                  warning alarm,
                  otherwise it will be set to
       event(3) - if there was at least one alarm event (including
                  state on,off events) since the last clear operation."
      ::= { statAgnGen 11 }

agnSMaskedAlrStat OBJECT-TYPE
      SYNTAX  INTEGER
       {
  off      (2),
  event    (3),
  minor    (4),
  major    (5),
     warning  (6),
  critical (7)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Indicates the alarm state in the agent level,[ i.e. lower
       level (card/port) alarms not included] including Masked
       alarms.
    critical(7) - when there is at least one active (state ON)
                  critical alarm,
                  otherwise it will be set to
       major(5) - when there is at least one active (state ON)
                  major alarm,
                  otherwise it will be set to
       minor(4) - if there is at least one active (state ON) minor
                  alarm,
                  otherwise it will be set to
       warning(6) - if there is at least one active (state ON)
                  warning alarm,
                  otherwise it will be set to
       event(3) - if there was at least one alarm event (including
                  state on,off events) since the last clear operation."
      ::= { statAgnGen 12 }

agnSMaskedAlrStatAll OBJECT-TYPE
      SYNTAX  INTEGER
       {
  off      (2),
  event    (3),
  minor    (4),
  major    (5),
     warning  (6),
  critical (7)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Indicates the alarm state of the entire agent, i.e.
       including card and port alarms status,including
       Masked alarms.
    critical(7) - when there is at least one active (state ON)
                  critical alarm,
                  otherwise it will be set to
       major(5) - when there is at least one active (state ON)
                  major alarm,
                  otherwise it will be set to
       minor(4) - if there is at least one active (state ON) minor
                  alarm,
                  otherwise it will be set to
       warning(6) - if there is at least one active (state ON)
                  warning alarm,
                  otherwise it will be set to
       event(3) - if there was at least one alarm event (including
                  state on,off events) since the last clear operation."
      ::= { statAgnGen 13 }

agnSTstStatAll OBJECT-TYPE
      SYNTAX  INTEGER
       {
  off(2),
  on (3)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "on(3) - when there is at least one test in progress in one
               of the agent cards,
       otherwise the value will be off(2)."
      ::= { statAgnGen 14 }

agnSAlrTable OBJECT-TYPE
      SYNTAX SEQUENCE OF AgnSAlrEntry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
      "List of agent related alarms and indications for alarms at
       system level."
      ::= { statAgnGen 15 }

agnSAlrEntry OBJECT-TYPE
      SYNTAX AgnSAlrEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX { agnSAlrIdx}
      ::= { agnSAlrTable 1}

AgnSAlrEntry ::=
      SEQUENCE {
  agnSAlrIdx              Integer32,
  agnSAlrCodeDescription  DisplayString,
  agnSAlrCode             Integer32,
  agnSAlrSeverity         INTEGER,
  agnSAlrState            INTEGER,
  agnSAlrCounter          Integer32,
  agnSAlrMask             INTEGER,
  agnSAlrInvert           INTEGER
      }

agnSAlrIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A unique number to identify an entry in the alarm status table
       of the agent."
      ::= { agnSAlrEntry 1 }

agnSAlrCodeDescription OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..255))
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute is a full text description of the alarm .
       The alarm description includes the following information:
       alarm code, alarm text, alarm severity, Masked or Inverted
       flag and counter."
     ::= { agnSAlrEntry 2 }

agnSAlrCode OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A code identifying the alarm of an entry in the alarm status
       table at system level."
      ::= { agnSAlrEntry 3 }

agnSAlrSeverity OBJECT-TYPE
      SYNTAX  INTEGER
       {
  event    (3),
  minor    (4),
  major    (5),
  warning  (6),
  critical (7)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The severity of the alarm."
      ::= { agnSAlrEntry 4 }

agnSAlrState  OBJECT-TYPE
      SYNTAX  INTEGER
       {
  off(2),
  on (3)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "State of the alarm."
      ::= { agnSAlrEntry 5 }

agnSAlrCounter OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A counter - how many times the alarm occured since last
       clear operation.
       ON and OFF Alarm will be counted separately."
      ::= { agnSAlrEntry 6 }

agnSAlrMask  OBJECT-TYPE
      SYNTAX  INTEGER
       {
  off(2),
  on (3)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Alarm mask : on/off."
      ::= { agnSAlrEntry 7 }

agnSAlrInvert  OBJECT-TYPE
      SYNTAX  INTEGER
       {
  off(2),
  on (3)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Alarm invert : on/off."
      ::= { agnSAlrEntry 8 }


agnSClearAlrCmd  OBJECT-TYPE
      SYNTAX  INTEGER
       {
  off(2),
  on (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Setting this attribute to ON, enforce a  clear operation on
       all the agent(general) events. General alarms are alarms
       which are not specific to a card or port. The clear
       operation will not be applied for masked/inverted alarms."
      ::= { statAgnGen 16 }

agnSClearAllAlrCmd OBJECT-TYPE
      SYNTAX  INTEGER
       {
  off(2),
  on (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Setting this attribute to ON, enforce a clear operation on
       all MUX alarm events at the levels of agent, slots and ports.
       The clear operation will not be applied for masked/inverted
       alarms."
      ::= { statAgnGen 17 }

agnSSanityCheckStatus OBJECT-TYPE
      SYNTAX  INTEGER
       {
  unknown (1),
  fail    (2),
  warning (3),
  ok      (4)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Upon completion of the Sanity check process on the TmpCnfg
       this attribute will be set to:
       FAIL(2) - when there is at least one error encountered and
                 possibly some warnings.
       WARNING(3) - when there are only warnings.
       otherwise, the value will be OK(4).
       The value will be UNKNOWN(1) if changes were made in the
       TmpCnfg following the last Sanity check."
      ::= { statAgnGen 18 }

agnSNoOfSanityCheckErr OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This entry indicates the number of errors/warnings discovered
       by the last SanityCheck process."
      ::= { statAgnGen 19 }

agnSErrListTable OBJECT-TYPE
      SYNTAX SEQUENCE OF AgnSErrListEntry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
      "List of errors and warnings found during Sanity Check
       process."
      ::= { statAgnGen 20 }

agnSErrListEntry OBJECT-TYPE
      SYNTAX AgnSErrListEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX { agnSErrIdx}
      ::= { agnSErrListTable 1}

AgnSErrListEntry ::=
      SEQUENCE {
     agnSErrIdx          Integer32,
     agnSErrDescription  DisplayString 
               }

agnSErrIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Unique number to identify an entry in the  error list table.
       The maximum entry  value cannot exceed the value of
       'agnSNoOfSanityCheckErr'. "
    ::= { agnSErrListEntry 1}

agnSErrDescription OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..255))
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute is a full text description of the sanity check
       error including error code, slot and port numbers related to
       the code ."
  ::= { agnSErrListEntry 2}

agnSMaxNoOfCnfg OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Maximum number of configurations that can be defined and
       stored in the MUX.
       If the mux has a large capacity, the maximum will be limited
       to  254."
      ::= { statAgnGen 21}
-- return 1 (db1) in phase I

agnSCnfgTable OBJECT-TYPE
      SYNTAX SEQUENCE OF AgnSCnfgEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
      "This table contains an entry per configuration. It indicates
       if the configuration is valid."
      ::= { statAgnGen 22 }
--  - in phase I only one entry

agnSCnfgEntry OBJECT-TYPE
      SYNTAX AgnSCnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX { agnSEntryIdx}
      ::= {agnSCnfgTable  1}

AgnSCnfgEntry ::=
      SEQUENCE  {
 agnSEntryIdx         Integer32,
 agnSEntryIsValid     INTEGER
      }

agnSEntryIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Unique number to identify an entry in the configuration table."
    ::= { agnSCnfgEntry 1}

agnSEntryIsValid OBJECT-TYPE
      SYNTAX  INTEGER
       {
  no  (2),
  yes (3)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the specific configuration
       is valid in the MUX . Value of NO indicates: no such
       configuration  in the MUX. "
    ::= { agnSCnfgEntry 2}

--
-- Wan agent configuration information
--
agnCSanityCheckCmd OBJECT-TYPE
      SYNTAX  INTEGER
       {
       off(2),
       on (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Setting this attribute to on(3) will initiate the process
       of Sanity check on the TmpCnfg. Upon completion the value
       will automatically be changed to off(2)."
      ::= { cnfgAgnGen 1 }

agnCSaveCnfgIdxCmd OBJECT-TYPE
      SYNTAX  Integer32   (1..100)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute specifies the Id of the target RealCnfg to
       which the TmpCnfg should be transferred. Upon set command the
       MUX will initiate the Sanity-Check  process first. If
       successful, the actual transfer will be performed. If warnings
       are detected, the user will have to perform the command again
       to confirm the operation. Setting this object a second time
       to the same value without performing any change in the database,
       will cause the result: agnSSanityCheckStatus = unknown"
      ::= { cnfgAgnGen 2 }
-- In phase I only the value 1 (Cnfg1) is valid.

agnCLoadCnfgIdxCmd OBJECT-TYPE
      SYNTAX  Integer32  (1..100)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute specifies the Id of the source Cnfg to be
       loaded into the TmpCnfg. Upon set operation the actual
       transfer will be initiated.
       The operation is valid only on Valid configurations
       (agnSEntryIsValid)"
      ::= { cnfgAgnGen 3 }
-- In phase I only the value 1 (Cnfg1) is valid.


agnCClkSrcTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF AgnCClkSrcEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
      "All the entries of this table are identical (have the same
       value) for all the configurations (1..100) except the
       TmpCnfg.
       The write operation into the Table Objects is valid only
       for the TmpCnfg entry."
       ::= { cnfgAgnGen 4}

agnCClkSrcEntry OBJECT-TYPE
      SYNTAX AgnCClkSrcEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {agnCClkCnfgIdx, agnCClkSrcIdx}
      ::= { agnCClkSrcTable 1}

AgnCClkSrcEntry ::=
      SEQUENCE {
   agnCClkCnfgIdx      Integer32,
   agnCClkSrcIdx       Integer32,
   agnCClkSrcMode      INTEGER,
   agnCClkSrcSlt       INTEGER,
   agnCClkSrcPrt       Integer32
      }

agnCClkCnfgIdx OBJECT-TYPE
      SYNTAX Integer32 (1..255)
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg(1..100) being
       accessed and Idx 255 relates to the TmpCnfg."
      ::= { agnCClkSrcEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.

agnCClkSrcIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..2)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "An index to the table. There are only two entries to this
       table.
       Index 1 points to the Master clock parameters and Index 2
       points to the Fallback clock parameters"
      ::= { agnCClkSrcEntry 2}

agnCClkSrcMode OBJECT-TYPE
      SYNTAX  INTEGER
       {
           internal   (1),
           rxClk      (2),
		   adaptive   (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The source of the nodal timing."
      ::= { agnCClkSrcEntry 3}

agnCClkSrcSlt OBJECT-TYPE
      SYNTAX  INTEGER
        {
       notApplicable   (1),
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
     }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This entry is valid only when we are working in rxClk mode.
       For an invalid entry, the return value will be '7fff'h."
      ::= { agnCClkSrcEntry 4}

agnCClkSrcPrt OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This entry is valid only when we are working in rxClk or 
       adaptive mode.
       For an invalid entry, the return value will be '7fff'h.
       - For rxClk mode, the values can be:
              exPrt1    (1) ,
              exPrt2    (2) ,
              exPrt3    (3) ,
              exPrt4    (4) ,
              exPrt5    (5) ,
              exPrt6    (6) ,
              exPrt7    (7) ,
              exPrt8    (8) ,
              exPrt9    (9) ,
              exPrt10  (10) ,
              exPrt11  (11) ,
              exPrt12  (12) ,
              notApplicable   (100),
	 	 	  inPrt1  (101) ,
	 	 	  inPrt2  (102) ,
	 	 	  inPrt3  (103) ,
	 	 	  inPrt4  (104)
       - For adaptive mode, the value will be the ifIndex of the 
         selected IP Bundle."
      ::= { agnCClkSrcEntry 5}

agnCDeleteCnfgIdxCmd OBJECT-TYPE
  SYNTAX  Integer32 (1..100)
  MAX-ACCESS  read-write
  STATUS  current
  DESCRIPTION
  "Setting this attribute will delete the requested DB
   from the NVRAM ."
  ::= { cnfgAgnGen 5 }

agnCDefaultCnfgIdxCmd OBJECT-TYPE
  SYNTAX  Integer32 (1..100)
  MAX-ACCESS  read-write
  STATUS  current
  DESCRIPTION
  "Setting this attribute will define the desired working
   configuration when no conditions of the Flip DB Table are
   fulfilled and no Net GO command was issued. This command
   will be accepted only if the Configuration number exists
   (agnSEntryIsValid=yes)."
  ::= { cnfgAgnGen 6 }

agnCnfgDataTable OBJECT-TYPE
      SYNTAX SEQUENCE OF AgnCnfgDataEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
      "This table contains data about the agent configurations.
       The table will support only data about valid configurations
       of the agent."
       ::= { cnfgAgnGen 7}

agnCnfgDataEntry OBJECT-TYPE
      SYNTAX AgnCnfgDataEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {agnCnfgIdx}
      ::= { agnCnfgDataTable 1}

AgnCnfgDataEntry ::=
      SEQUENCE {
   agnCnfgIdx      Integer32,
   agnCnfgDesc     DisplayString,
   agnCnfgUpdDate  DisplayString,
   agnCnfgUpdTime  DisplayString,
   agnCnfgUpdMnger IpAddress
      }

agnCnfgIdx OBJECT-TYPE
      SYNTAX Integer32 (1..255)
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "This object indicates the Idx of the agent' Cnfg the following 
       objects refer.
       255=Temporary Cnfg (Set is done only to this configuration)."
      ::= { agnCnfgDataEntry 1}
-- Only the values 1..10, 255 are valid.

agnCnfgDesc OBJECT-TYPE
      SYNTAX DisplayString (SIZE (0..30))
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
      "This object is a description of the Configuration, entered
       by user, to enhance Cnfg recognition."
      ::= { agnCnfgDataEntry 2}

agnCnfgUpdDate  OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..255))
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates the date when last update of this
       configuration was performed, as it is known by the
       agent using its own real-time clock. The format would be as
       specified by the agnSDateFormat.
       When update is performed, the agent should save the date."
      ::= { agnCnfgDataEntry 3 }

agnCnfgUpdTime  OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..255))
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates the time when last update of this
       configuration was performed, as it is known by the
       agent using its own real-time clock.
       When update is performed, the agent should save the time."
      ::= { agnCnfgDataEntry 4 }

agnCnfgUpdMnger  OBJECT-TYPE
      SYNTAX  IpAddress
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates the IP Address of the Manager who
       performed the last update of this configuration.
       When update is performed, the agent should save the
       IP Address of the Manager who commanded the update.
       That will enable a manager to know if he performed the last
       update, or another manager did."
      ::= { agnCnfgDataEntry 5 }


agnCnfgAlarm   OBJECT IDENTIFIER ::= { cnfgAgnGen 8}

agnCnfgAlrFilterWindow OBJECT-TYPE
      SYNTAX Integer32 (0..255)
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
      "Window of time, in seconds.
       During this Window, the alarms filter is performed.
       Same Window for all agent alarms that need filtering.
       Upon end of the Window, the state of the alarm is updated
       and a new Window starts.
       If no alarm needs filtering, this object's value will not be
       used."
      ::= { agnCnfgAlarm 1}

agnCnfgAlrTable OBJECT-TYPE
      SYNTAX SEQUENCE OF AgnCnfgAlrEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
      "This table enables the user to set attributes to each alarm.
       Setting  for a non-existing entry agnCnfgAlrMask,
       agnCnfgAlrInvert or agnCnfgAlrFilter to 'yes'(or yesAndSave
       for Mask) will add this new entry to the table.
       Setting  for an existing entry agnCnfgAlrMask/
       agnCnfgAlrInvert/agnCnfgAlrFilter (one or more) to 'no'
       (noAndSave for Mask)  so that ALL  these objects' values are
       'no' , will delete this entry from the table.
       For agnCnfgAlrMask, only if [(last saved value=noAndSave)
       AND (new value is 'no' or 'noAndSave')] the object's value
       is considered 'no' for deleting the entry.
       
       For some products (like MP, MPH, Vmux2100) the Active Alarms are always
       part of the table and cannot be removed even if their Mask/Invert/Filter
       are No."
       ::= { agnCnfgAlarm 2}

agnCnfgAlrEntry OBJECT-TYPE
      SYNTAX AgnCnfgAlrEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {agnCnfgAlrCode, agnCnfgAlrSlot, agnCnfgAlrPort}
      ::= { agnCnfgAlrTable 1}

AgnCnfgAlrEntry ::=
      SEQUENCE {
   agnCnfgAlrCode        Integer32,
   agnCnfgAlrSlot        INTEGER,
   agnCnfgAlrPort        Integer32,
   agnCnfgAlrMask        INTEGER,
   agnCnfgAlrInvert      INTEGER,
   agnCnfgAlrFilter      INTEGER,
   agnCnfgAlrFilterSet   Integer32,
   agnCnfgAlrFilterReset Integer32,
   agnCnfgAlrSeverity    INTEGER 
    
	}

agnCnfgAlrCode OBJECT-TYPE
      SYNTAX Integer32
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The alarm code. The following attributes refer this code."
      ::= { agnCnfgAlrEntry 1 }

agnCnfgAlrSlot OBJECT-TYPE
      SYNTAX INTEGER
      {
       psA   (1),
       psB   (2),
       clA   (3),
       clB   (4),
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
       io13 (17),
       io14 (18),
       io15 (19),
       all           (200),
       notApplicable (255)
   }
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The alarm slot. The following attributes apply for the alarm
       code and slot selected.
       all = the attributes apply to all slots.
       notApplicable = the selected alarm is for system level.
       For the Vmux2100 Main Board clA  (3) is used."
      ::= { agnCnfgAlrEntry 2 }

agnCnfgAlrPort OBJECT-TYPE
      SYNTAX Integer32
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The alarm port. The following attributes apply for the alarm
       code,slot and port selected.
       200 = all = the attributes apply to all ports of the selected slot.
             When selected Slot is 'all', only 'all' or	'notApplicable' are valid  
             Port selections.
       notApplicable = the selected alarm is for system or card
                       level.
					   =255 for MP
					   =100 for DXC
	   - For MP:
	     - valid cards' ports are: exPrt1(1)..exPrt16(16)
								   inPrt1(101)..inPrt48 (148)
		 - IP Bundles 
	   - For DXC, the port index will include the Slot, as for all DXC 
	     tables: [(IO Slot+10)&n]  ; n=odd  for external ports
		                             n=even for internal ports."
      ::= { agnCnfgAlrEntry 3 }

agnCnfgAlrMask OBJECT-TYPE
      SYNTAX INTEGER
      {
       no         (1),
       noAndSave  (2),
       yes        (3),
       yesAndSave (4)
   }
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
      "An attribute defining the desired Mask state of an alarm .
       no - unmask (this command is not saved in agent's common
            database)
       noAndSave -  unmask ; this command is saved in agent's
             common database
       yes - mask  (this command is not saved in agent's
             common database)
       yesAndSave - mask  ; this command is saved in
             agent's common database.
       Commands that are not saved, will be lost upon power-up or
       selected card removal.      "
      ::= { agnCnfgAlrEntry 4 }

agnCnfgAlrInvert OBJECT-TYPE
      SYNTAX INTEGER
      {
       no            (2),
       yes           (3)
   }
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
      "An attribute defining the desired Invert state of an alarm .
       no  - not inverted.
       yes - inverted. For MP, it is not applicable for alarms
             that are currently OFF."
      ::= { agnCnfgAlrEntry 5 }

agnCnfgAlrFilter OBJECT-TYPE
      SYNTAX INTEGER
      {
       no            (2),
       yes           (3)
   }
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
      "An attribute defining if Filter is desired for the alarm .
       no  - no  filter.
       yes - filter activate.

       This filter is activated within a window of time defined by
       agnCnfgAlrFilterWindow.
       Its purpose is to avoid frequent changes of an alarm between
       ON/OFF states."
      ::= { agnCnfgAlrEntry 6 }

agnCnfgAlrFilterSet OBJECT-TYPE
      SYNTAX Integer32
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
      "This is a top threshold causing the alarm that passes it,
       to be declared Set (ON) at the end of the respective
       window of time.
       - For alarms defined by default as state alarms (minor,major)
         this value will be in [%].
       - For alarms defined by default as events, this value will be
         an integer meaning how many times this event should appear
         at least, during the window in order to be considered ON.
       The maximum value will be 255.
       This value should be greater than the one of
       agnCnfgAlrFilterReset.
       Agents that do not support Alarms Filter, will return 0."
      ::= { agnCnfgAlrEntry 7 }

agnCnfgAlrFilterReset OBJECT-TYPE
      SYNTAX Integer32
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
      "This is a bottom threshold causing the alarm that does not
       pass it, to be declared Reset (ON) at the end of the
       respective window of time.
       - For alarms defined by default as state alarms (minor,major)
         this value will be in [%].
       - For alarms defined by default as events, this value will be
         an integer meaning how many times this event should appear
         at most, during the window, in order to be considered OFF.
       This value should be less than the one of
       agnCnfgAlrFilterSet.
       Agents that do not support Alarms Filter, will return 0."
      ::= { agnCnfgAlrEntry 8 }


agnCnfgAlrSeverity     OBJECT-TYPE
      SYNTAX INTEGER
      {
       event    (3),
       minor    (4),
       major    (5),
       warning  (6),
       critical (7)
       }
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
      "An attribute defining desired severity of an alarm code 
      per slot/port "
      ::= { agnCnfgAlrEntry 9 }


agnCnfgAlrReportTable OBJECT-TYPE
      SYNTAX SEQUENCE OF AgnCnfgAlrReportEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
      "This table enables the user to configure the desired Alarm
       Reports according to alarms severity."
       ::= { agnCnfgAlarm 3}

agnCnfgAlrReportEntry OBJECT-TYPE
      SYNTAX AgnCnfgAlrReportEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {agnCnfgAlrReportType}
      ::= { agnCnfgAlrReportTable 1}

AgnCnfgAlrReportEntry ::=
      SEQUENCE {
   agnCnfgAlrReportType        INTEGER,
   agnCnfgAlrStartReportOn     INTEGER,
   agnCnfgAlrStartReportOff    INTEGER
      }

agnCnfgAlrReportType OBJECT-TYPE
      SYNTAX INTEGER
         {
          trap        (1),
          buffer      (2),
          relay       (3),	 --Relay 1 = R1
          alrLedOn    (4),	 --Minor LED
          alrLedBlink (5),	 --Major LED
		  relay2      (6)    --Relay 2 = R2
         }
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The alarm report type.
       trap - traps will be sent only for alarms having the
              selected On/Off severity or higher.
       buffer - only alarms having the selected On/Off severity and
                higher, will be reported to the buffer.
       relay -  relay contact will be activated only for alarms
                having the selected On severity or higher.
				For products having 2 relays, this is the R1 Relay.

       alrLedOn/alrLedBlink - user should select a higher severity
                (ReportOn) for alrLedBlink than for alrLedOn
                (Blinking Led means a more severe alarm than steady
                 ON Led).
       alrLedOn - MTCL-1 Alarm Led will be ON only when
                agnSAlrStatusAll equals the selected severity or
                higher, but lower severity than that selected for
                'alrLedBlink'.
				For products having 2 LEDs, this is the Minor LED.
       alrLedBlink - MTCL-1 Alarm Led will Blink only when
                agnSAlrStatusAll equals the selected severity or
                higher.
				For products having 2 LEDs, this is the Major LED.
       relay2 -  relay 2 contact will be activated only for alarms
                having the selected On severity or higher.
				This is the R2 Relay."
      ::= { agnCnfgAlrReportEntry 1 }

agnCnfgAlrStartReportOn OBJECT-TYPE
      SYNTAX INTEGER
         {
          noReport (2),
          event    (3),
          minor    (4),
          major    (5),
          warning  (6),
          critical (7)
         }  
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
      "This object specifies the severity from which alarms will 
       be reported. Alarms having this severity or higher, will be
       reported.
       This object specifies the report severity only for alarms
       that turn to ON state.
       noReport - no Report at all (for any severity)."
      ::= { agnCnfgAlrReportEntry 2 }

agnCnfgAlrStartReportOff OBJECT-TYPE
      SYNTAX INTEGER
         {
        notApplicable (1),
        noReport (2),
        event    (3),
        minor    (4),
        major    (5),
        warning  (6),
        critical (7)
         }  
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
      "This object specifies the severity from which alarms will 
       be reported. Alarms having this severity or higher, will be
       reported.
       This object specifies the report severity only for alarms
       that turn to OFF state. 
       notApplicable - for 'relay','alrLedOn','alrLedBlink', 'relay2' report 
                       types, in MP.
       noReport - no Report at all (for any severity)."
      ::= { agnCnfgAlrReportEntry 3 }

agnCOffsetCmd OBJECT-TYPE
      SYNTAX INTEGER
      {
       notApplicable (1),
       normal        (2),
       u1            (3)
      }
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
      "An object defining special user request.
       notApplicable - is RO value for products that do not support this object.
       normal -  nothing special
       u1 - user 1 - for all Voice cards, the DISPLAYED Tx and Rx Levels
            will have the following Offsets:
            - 2 Wires port: Tx Level: the base value (for 0dBm) = 0
                            Rx Level: the base value (for 0dBm) = -2
            - 4 Wires port: Tx Level: the base value (for 0dBm) = -16
                            Rx Level: the base value (for 0dBm) = 7    
            The MIB and application DB will use the values without Offset."
      ::= { cnfgAgnGen 9 }


--System T1/E1 Ring Table
--
--This table contains all ML ports that participate in a T1/E1 Ring,
--and their ML port pair. 
--The table indexes are Cnfg and the Primary card & port

agnCT1E1RingTable OBJECT-TYPE
      SYNTAX SEQUENCE OF AgnCT1E1RingEntry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
      "Configuration of all T1/E1 Ring ML cards and ports.
       The write operation into the table objects is valid only
       for the TmpCnfg.
       A Slot/Port that does not participate in the T1/E1 Ring, 
       will not exist in this table.
       A ML port that exists in this table, cannot exist at the same
       time in the IO Redundancy table (sysCRdnTable)."
      ::= { cnfgAgnGen 10 }

agnCT1E1RingEntry OBJECT-TYPE
      SYNTAX AgnCT1E1RingEntry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
	  "An Entry in table agnCT1E1RingTable"
      INDEX { agnCT1E1RingCnfgIdx, agnCT1E1RingPrimeSlot, agnCT1E1RingPrimePort}
      ::= { agnCT1E1RingTable 1}

AgnCT1E1RingEntry ::=
      SEQUENCE {
     agnCT1E1RingCnfgIdx   Integer32,
     agnCT1E1RingPrimeSlot INTEGER,
     agnCT1E1RingPrimePort Integer32,
     agnCT1E1RingSecSlot   INTEGER,
     agnCT1E1RingSecPort   Integer32,
	 agnCT1E1RingRecTime   Integer32,
     agnCT1E1RingRowStatus RowStatus,
	 agnCT1E1RingWTR       Unsigned32,
	 agnCT1E1RingDualFailDetection INTEGER
      }

agnCT1E1RingCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates the Idx of the Cnfg(1..255) being 
       accessed ; Idx of 255 relates to the TmpCnfg."
      ::= { agnCT1E1RingEntry 1 }

agnCT1E1RingPrimeSlot OBJECT-TYPE
      SYNTAX  INTEGER 
       {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
       notApplicable (255)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The slot number of the Primary card of the Ring Pair."      
	  ::= { agnCT1E1RingEntry 2 }

agnCT1E1RingPrimePort OBJECT-TYPE
      SYNTAX  Integer32 
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The port number in the Primary Card.
	   For external ports, the value will be as that of the port in the
	       card. Example: external-3 -> 3
                          external-4 -> 4
	   For internal ports, the value will be 100 + the port in the
	       card. Example: internal-1 -> 101
                          internal-4 -> 104  "      
      ::= { agnCT1E1RingEntry 3 }

agnCT1E1RingSecSlot OBJECT-TYPE
      SYNTAX  INTEGER 
       {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
       notApplicable (255)
       }
      MAX-ACCESS  read-create
      STATUS  current
      DESCRIPTION
      "The slot number of the Secondary card of the Ring Pair."      
	  ::= { agnCT1E1RingEntry 4 }

agnCT1E1RingSecPort OBJECT-TYPE
      SYNTAX  Integer32 
      MAX-ACCESS  read-create
      STATUS  current
      DESCRIPTION
      "The port number in the Secondary Card.
	   For external ports, the value will be as that of the port in the
	       card. Example: external-3 -> 3
                          external-4 -> 4
	   For internal ports, the value will be 100 + the port in the
	       card. Example: internal-1 -> 101
                          internal-4 -> 104  "      
      ::= { agnCT1E1RingEntry 5 }

agnCT1E1RingRecTime OBJECT-TYPE
      SYNTAX  Integer32 
      MAX-ACCESS  read-create
      STATUS  current
      DESCRIPTION
      "T1/E1 Ring Recovery Time (sec).
       Valid Values: 1..99, 65535.
       65535=NA."
      ::= { agnCT1E1RingEntry 6 }

agnCT1E1RingRowStatus  OBJECT-TYPE
      SYNTAX  RowStatus
      MAX-ACCESS   read-create
      STATUS   current
      DESCRIPTION
      "This parameter allows NMS to create/delete entries of this table.
       The only possible supported RowStatus vaules are
       active (1) and destroy (6)."
      ::= { agnCT1E1RingEntry 7 }

agnCT1E1RingWTR OBJECT-TYPE
      SYNTAX  Unsigned32 
      MAX-ACCESS  read-create
      STATUS  current
      DESCRIPTION
      "T1/E1 Ring Wait to Restore (sec).
       Valid Values: 0..999, 65535.
       65535=NA.
       When the value <> 65535, the value of agnCT1E1RingRecTime must be 65535."
      ::= { agnCT1E1RingEntry 8 }

agnCT1E1RingDualFailDetection OBJECT-TYPE
      SYNTAX  INTEGER 
       {
       disable (2),
       enable  (3)
       }
      MAX-ACCESS  read-create
      STATUS  current
      DESCRIPTION
      "T1/E1 Ring - Dual Failure Detection enable/disable."      
	  ::= { agnCT1E1RingEntry 9 }


agnCMainExitPort OBJECT-TYPE
      SYNTAX INTEGER
      {
       notApplicable   (1),
       eth             (2),
       e1T1SerialLink  (3)
      }
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
      "An object defining the Main Exit Port for the Data of the device.
       In the Vmux-120 Device the Data can Exit via one of the 2 existing ports:
       1. Ethernet port (2)
       2. A port that can be E1 or T1 or a Serial Link (3)."
      ::= { cnfgAgnGen 11 }

-- 	Backup Configuration Table for Main Link Module
 
agnCBuMlTable OBJECT-TYPE
      SYNTAX SEQUENCE OF AgnCBuMlEntry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
      "Configuration for Primary, Secondary and Third Link.
       These are used for Link Backup."
      ::= { cnfgAgnGen 12 }

agnCBuMlEntry OBJECT-TYPE
      SYNTAX AgnCBuMlEntry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
	  "An Entry in table agnCBuMlTable"
      INDEX { agnCBuMlCnfgIdx, agnCBuMlRole}
      ::= { agnCBuMlTable 1}

AgnCBuMlEntry ::=
      SEQUENCE {
     agnCBuMlCnfgIdx          Integer32,
     agnCBuMlRole             INTEGER,
     agnCBuMlType             INTEGER,
     agnCBuMlDefaultGateway   IpAddress,
     agnCBuMlSubnetMask       IpAddress,
	 agnCBuMlOamFrequency     Integer32,
	 agnCBuMlOamTimeoutCycles Integer32,
	 agnCBuMlWaitToRestore    Unsigned32,
	 agnCBuMlBfdSessionNum    Unsigned32
	 }

agnCBuMlCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
     "This object indicates the Index of the Configuration database (1..255) being 
       accessed. Index of 255 relates to the Temporary Configuration."
      ::= { agnCBuMlEntry 1 }

agnCBuMlRole OBJECT-TYPE
      SYNTAX  INTEGER 
       {
       primary   (2),
       secondary (3),
       third     (4),
	   fourth    (5)
       }
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
      "The Role of the Link. Primary Link is the Link that should usually work.
      If the Primary Link fails, the data will go through the Secondary Link.
      If both Primary and Secondary Links fail, the data will go through the Third
      Link, provided it is up."      
	  ::= { agnCBuMlEntry 2 }

agnCBuMlType OBJECT-TYPE
      SYNTAX  INTEGER 
       {
       none  (2),
       e1T1a (3),
       e1T1b (4),
	   eth   (5),
	   ethNetUser (6)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The Type of the Link.
       For E1/T1 the Link can be Link A - e1T1a or Link B - e1T1b.
       For ETH-NET, eth (5) can be used.
       For ETH-NET/USER ethNetUser (6) can be used."      
	  ::= { agnCBuMlEntry 3 }

agnCBuMlDefaultGateway OBJECT-TYPE
      SYNTAX  IpAddress 
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Default Gateway's IP Address."    
	  ::= { agnCBuMlEntry 4 }
  
agnCBuMlSubnetMask  OBJECT-TYPE
      SYNTAX  IpAddress 
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The Link subnet mask."  
	  ::= { agnCBuMlEntry 5 }

agnCBuMlOamFrequency  OBJECT-TYPE
      SYNTAX  Integer32 
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Time in sec. between 2 OAM packets." 
	  ::= { agnCBuMlEntry 6 }

agnCBuMlOamTimeoutCycles  OBJECT-TYPE
      SYNTAX  Integer32 
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "No. of cycles the Link will send OAM packets without receiving a response
      from the remote Link before switching to the Backup Link."
	  ::= { agnCBuMlEntry 7 }

agnCBuMlWaitToRestore  OBJECT-TYPE
    SYNTAX       Unsigned32 
    MAX-ACCESS   read-write
    STATUS       current
    DESCRIPTION
    "This object defines traffic recovery time (in milliseconds) 
     of the link after its recovery.
     This object is applicable only when Recovery Mode is revertive."
    ::= { agnCBuMlEntry 8 }

agnCBuMlBfdSessionNum  OBJECT-TYPE
    SYNTAX       Unsigned32 
    MAX-ACCESS   read-write
    STATUS       current
    DESCRIPTION
    "This object defines the BFD (Bidirectional Forwarding Detection) session number of the link.
     When no session exists or when N/A, the value will be 0."
    ::= { agnCBuMlEntry 9 }


agnCQ50Table OBJECT-TYPE
      SYNTAX SEQUENCE OF AgnCQ50Entry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
      "Table for the device Q50 parameters.
       Q50 is a Signaling protocol used between PBX devices.
       It is possible to control the initiation of calls using Q.50.
       This is useful for devices when there is a congestion."
      ::= { cnfgAgnGen 13 }

agnCQ50Entry OBJECT-TYPE
      SYNTAX AgnCQ50Entry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
	  "An Entry in table agnCQ50Table"
      INDEX { agnCQ50CnfgIdx}
      ::= { agnCQ50Table 1}

AgnCQ50Entry ::=
      SEQUENCE {
     agnCQ50CnfgIdx          				Integer32,
     agnCQ50StopCallsThresh  				Integer32,
     agnCQ50DiscardPktThresh 				Integer32,
	 agnCQ50BlockNewModemVbdCallsThresh		Integer32,
	 agnCQ50BlockNewModemRelayCallsThresh	Integer32
 	 }

agnCQ50CnfgIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
      "This object indicates the Index of the Configuration database (1..255) being 
       accessed. Index of 255 relates to the Temporary Configuration."
      ::= { agnCQ50Entry 1 }

 agnCQ50StopCallsThresh OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the Bandwidth Threshold percent (%) above which
       new Calls from the PBX will be disabled."
      ::= { agnCQ50Entry 2 }

agnCQ50DiscardPktThresh OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the Bandwidth Threshold percent (%) above which
       voice packets will be discarded. Usually, the value selected should be higher
       than the value of agnCQ50StopCallsThresh."
      ::= { agnCQ50Entry 3 }

agnCQ50BlockNewModemVbdCallsThresh OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the Modem VBD Calls Threshold percent (%) above which
       new modem calls will be rejected."
      ::= { agnCQ50Entry 4 }

agnCQ50BlockNewModemRelayCallsThresh OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the Modem Relay Calls Threshold percent (%) above which
       new modem calls will be rejected."
      ::= { agnCQ50Entry 5 }


--
-- Compressed information.
--
-- Specially for RadView management station
--
agnCmprTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF AgnCmprEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "A table."
	::=  { cmprAgnGen 1 }

agnCmprEntry OBJECT-TYPE
      SYNTAX AgnCmprEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX { agnCmprTypIdx, agnCmprCnfgIdx ,agnCmprVersion}
      ::= {agnCmprTable  1}

AgnCmprEntry ::=
      SEQUENCE {
     agnCmprTypIdx      Integer32,
     agnCmprCnfgIdx     Integer32,
     agnCmprVersion     Integer32,
     agnCmprObj         OCTET STRING
      }

agnCmprTypIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Type of the Compressed being
       referred."
      ::= { agnCmprEntry 1}

agnCmprCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the configuration to which the
       Compressed information is  related."
      ::= { agnCmprEntry 2}

agnCmprVersion OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the version of the internal format
       of the Compressed data"
      ::= { agnCmprEntry 3}

agnCmprObj OBJECT-TYPE
      SYNTAX  OCTET STRING
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute is the compressed information itself."
      ::= { agnCmprEntry 4}


-- Compressed Dlci table in the Agent level
-- The only way of reading this table is by the command 'GET NEXT'

agnDlciCmprTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF AgnDlciCmprEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "A table."
	::=  {cmprAgnGen 2}

agnDlciCmprEntry OBJECT-TYPE
      SYNTAX AgnDlciCmprEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {agnDlciCmprCnfgIdx,agnDlciCmprVersion,agnDlciCmprDlciIdx}
      ::= {agnDlciCmprTable  1}

AgnDlciCmprEntry ::=
      SEQUENCE {
     agnDlciCmprCnfgIdx       Integer32,
     agnDlciCmprVersion       Integer32,
     agnDlciCmprDlciIdx       Integer32,
     agnDlciCmprObj          OCTET STRING
      }

agnDlciCmprCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the configuration to which the
       Compressed information is  related."
      ::= { agnDlciCmprEntry 1}

agnDlciCmprVersion OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the version of the internal format
       of the Compressed data"
      ::= { agnDlciCmprEntry 2}

agnDlciCmprDlciIdx  OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique identifier of  the Dlci,
       the compressed information relates to.
       The values are between 16 - 991."
      ::= { agnDlciCmprEntry 3}

agnDlciCmprObj OBJECT-TYPE
      SYNTAX  OCTET STRING
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute is the compressed information itself."
      ::= { agnDlciCmprEntry 4}

-- Compressed Status Alarm table at the Agent level
-- The only way of reading this table is by the command 'GET NEXT'

agnAlarmsCmprTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF AgnAlarmsCmprEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "A table."
	::=  {cmprAgnGen 3}

agnAlarmsCmprEntry OBJECT-TYPE
      SYNTAX AgnAlarmsCmprEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {agnAlarmsCmprVersion,agnAlarmsCmprAlarmIdx}
      ::= {agnAlarmsCmprTable  1}

AgnAlarmsCmprEntry ::=
      SEQUENCE {
     agnAlarmsCmprVersion      Integer32,
     agnAlarmsCmprAlarmIdx     Integer32,
     agnAlarmsCmprObj          OCTET STRING
      }

agnAlarmsCmprVersion OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the version of the internal
       format of the Compressed data"
      ::= { agnAlarmsCmprEntry 1}

agnAlarmsCmprAlarmIdx  OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A unique number to identify an entry in the alarm status table
       of the agent."
      ::= { agnAlarmsCmprEntry 2}

agnAlarmsCmprObj OBJECT-TYPE
      SYNTAX  OCTET STRING
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute is the compressed information itself."
      ::= { agnAlarmsCmprEntry 3}

-- Compressed History Alarms buffer
-- The only way of reading this table is by the command 'GET NEXT'

agnAlrBufCmprTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF AgnAlrBufCmprEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "A table."
	::=  {cmprAgnGen 4}

agnAlrBufCmprEntry OBJECT-TYPE
      SYNTAX AgnAlrBufCmprEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {agnAlrBufCmprVersion,agnAlrBufCmprAlarmIdx}
      ::= {agnAlrBufCmprTable  1}

AgnAlrBufCmprEntry ::=
      SEQUENCE {
     agnAlrBufCmprVersion      Integer32,
     agnAlrBufCmprAlarmIdx     Integer32,
     agnAlrBufCmprObj          OCTET STRING
      }

agnAlrBufCmprVersion OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the version of the internal format of
       the Compressed data"
      ::= { agnAlrBufCmprEntry 1}

agnAlrBufCmprAlarmIdx  OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A unique number to identify an entry in the history alarms
       buffer of the agent."
      ::= { agnAlrBufCmprEntry 2}

agnAlrBufCmprObj OBJECT-TYPE
      SYNTAX  OCTET STRING
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute is the compressed information itself."
      ::= { agnAlrBufCmprEntry 3}


-- Compressed Sanity Errors buffer
-- The only way of reading this table is by the command 'GET NEXT'


agnSCmprErrListTable OBJECT-TYPE
      SYNTAX SEQUENCE OF AgnSCmprErrListEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "A table."
	::=  { cmprAgnGen 5 }

agnSCmprErrListEntry OBJECT-TYPE
      SYNTAX AgnSCmprErrListEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {agnSCmprErrVersion,agnSCmprErrIdx}
      ::= { agnSCmprErrListTable 1}

AgnSCmprErrListEntry ::=
      SEQUENCE {
     agnSCmprErrVersion      Integer32,
     agnSCmprErrIdx          Integer32,
     agnSCmprErrObj          OCTET STRING
      }

agnSCmprErrVersion OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The version of the compressed data "
       ::= { agnSCmprErrListEntry 1}

agnSCmprErrIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Unique number to identify an entry in the errors list table.
       The maximum entry  value  cannot exceed the value of
       'agnSNoOfSanityCheckErr'. "
       ::= { agnSCmprErrListEntry 2}

agnSCmprErrObj OBJECT-TYPE
      SYNTAX  OCTET STRING
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute is a full text description of the error,
       including: error code, slot and port numbers related to the
       code ."
     ::= { agnSCmprErrListEntry 3}


-- New TS Assignment compressed table, per port 01/09/98
-- The only way of reading this table is by the command 'GET NEXT'

agnTsCmprTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF AgnTsCmprEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "A table."
	::=  { cmprAgnGen 6 }

agnTsCmprEntry OBJECT-TYPE
      SYNTAX AgnTsCmprEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX { agnTsCmprVerIdx,  agnTsCmprCnfgIdx , agnTsCmprSlotIdx,
              agnTsCmprPortIdx, agnTsCmprPduIdx }
      ::= {agnTsCmprTable  1}

AgnTsCmprEntry ::=
      SEQUENCE {
     agnTsCmprVerIdx      Integer32,
     agnTsCmprCnfgIdx     Integer32,
     agnTsCmprSlotIdx     Integer32,
     agnTsCmprPortIdx     Integer32,
     agnTsCmprPduIdx      Integer32,
     agnTsCmprData        OCTET STRING
      }

agnTsCmprVerIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates the version of the internal format
       of the Compressed data."
      ::= { agnTsCmprEntry 1}

agnTsCmprCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates the configuration to which the
       Compressed information is related.
       255=temporary configuration.
       Set can be performed only to the temporary configuration."
      ::= { agnTsCmprEntry 2}

agnTsCmprSlotIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates the Slot to which the
       Compressed information is  related.
       For MP-2100: IO-1..IO-12 = (5).. (16)
       For DXC-30 : IO-1..IO-15 = (5).. (19).
       NA=255."
      ::= { agnTsCmprEntry 3}

agnTsCmprPortIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates the Port within the Slot, to which the
       Compressed information is  related.
       For Port Index see each product's spec."
      ::= { agnTsCmprEntry 4}

agnTsCmprPduIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates the PDU index within the same port.
       That provides for the case when one PDU is not sufficient for all TS
       Assignment data of the same port."
      ::= { agnTsCmprEntry 5}

agnTsCmprData OBJECT-TYPE
      SYNTAX  OCTET STRING
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object is the compressed information itself. It provides
       information about all TSs of a port."
      ::= { agnTsCmprEntry 6}

-- Extended Compress General Table with 7 indexes -  10/02/99
-- Used for: V5.1 and V5.2 Variant 

agnXCmprTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF AgnXCmprEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "A table."
	::=  { cmprAgnGen 7 }

agnXCmprEntry OBJECT-TYPE
      SYNTAX AgnXCmprEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {agnXCmprTypIdx, agnXCmprVersion, agnXCmprIdx3,agnXCmprIdx4,
             agnXCmprIdx5, agnXCmprIdx6, agnXCmprIdx7}
      ::= {agnXCmprTable  1}

AgnXCmprEntry ::=
      SEQUENCE {
     agnXCmprTypIdx       Integer32,
     agnXCmprVersion      Integer32,
     agnXCmprIdx3         Integer32,
     agnXCmprIdx4         Integer32,
     agnXCmprIdx5         Integer32,
     agnXCmprIdx6         Integer32,
     agnXCmprIdx7         Integer32,
     agnXCmprObj          OCTET STRING
      }

agnXCmprTypIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Type of the Compressed being
       referred. 
       One of the types is V5.1 Variant data."
      ::= { agnXCmprEntry 1}

agnXCmprVersion OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the version of the internal format of
       the Compressed data."
      ::= { agnXCmprEntry 2}

agnXCmprIdx3 OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "3rd index - can be used for any purpose according to the 
       agnXCmprTypIdx.
       Example: for V5.1 Variant, this attribute indicates the configuration
       to which the Compressed information is  related.
       255=temporary configuration.
       Set can be performed only to the temporary configuration."
      ::= { agnXCmprEntry 3}

agnXCmprIdx4  OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "4th index - can be used for any purpose according to the 
       agnXCmprTypIdx.
       Example: for V5.1 Variant,this attribute indicates a unique number of 
       the slot position where the card is inserted.
	   Valid values: psA(1),psB(2),clA(3),clB(4),io1(5)..io12(16); notApplicable=255."
      ::= { agnXCmprEntry 4}

agnXCmprIdx5   OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "5th index - can be used for any purpose according to the 
       agnXCmprTypIdx.
       Example: for V5.1 Variant,this attribute indicates a unique identifier 
       of  the port	the compressed information relates to.
       Valid values: exPrt1    (1) .. exPrt12  (12) ,
                     inPrt1  (101) .. inPrt48 (148)."
      ::= { agnXCmprEntry 5}

agnXCmprIdx6  OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "6th index - can be used for any purpose according to the 
       agnXCmprTypIdx.
       Example: for V5.1 Variant,this attribute indicates the Variant index. 
       Valid values are: 0..127, 255 (= temp cnfg).Set can be performed only 
       to the temporary configuration."
      ::= { agnXCmprEntry 6}

agnXCmprIdx7  OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "7th index - can be used for any purpose according to the 
       agnXCmprTypIdx.
       Example: for V5.1 Variant,this attribute is not needed. Therefore, its 
       value will be always 255=notApplicable."
      ::= { agnXCmprEntry 7}

agnXCmprObj OBJECT-TYPE
      SYNTAX  OCTET STRING
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute is the compressed information itself."
      ::= { agnXCmprEntry 8}

--
-- Link Mapping Table for internal use
--
agnLinkMapTable OBJECT-TYPE
      SYNTAX SEQUENCE OF AgnLinkMapEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "A table."
	::=  { mapWanGen 1}

agnLinkMapEntry OBJECT-TYPE
      SYNTAX AgnLinkMapEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {mapLinkId}
      ::= {agnLinkMapTable 1}

AgnLinkMapEntry ::=
      SEQUENCE {
      mapLinkId               Integer32,
      mapLinkSltIdx           INTEGER,
      mapLinkPrtIdx           INTEGER,
      mapLinkStatus           INTEGER
      }

mapLinkId     OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A unique identifier of the link"
::=  {agnLinkMapEntry 1}

mapLinkSltIdx    OBJECT-TYPE
      SYNTAX  INTEGER
        {
          noConnect   (2),
       clA   (3),
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
    notApplicable (255)
     }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted.
       In the ?004 Unit the entries clA(3), io6(10)..io12(16) are
       not valid."
::=  {agnLinkMapEntry 2}

mapLinkPrtIdx  OBJECT-TYPE
      SYNTAX  INTEGER
      {
         exPrt1    (1) ,
         exPrt2    (2) ,
         exPrt3    (3) ,
         exPrt4    (4) ,
         exPrt5    (5) ,
         exPrt6    (6) ,
         exPrt7    (7) ,
         exPrt8    (8) ,
         exPrt9    (9) ,
         exPrt10  (10) ,
         exPrt11  (11) ,
         exPrt12  (12) ,
         noConnect  (100) ,
         inPrt1  (101) ,
         inPrt2  (102) ,
         inPrt3  (103) ,
         inPrt4  (104) ,
         inPrt5  (105) ,
         inPrt6  (106) ,
         inPrt7  (107) ,
         inPrt8  (108) ,
         inPrt9  (109) ,
         inPrt10 (110) ,
         inPrt11 (111) ,
         inPrt12 (112)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  port number. "
::=  {agnLinkMapEntry 3}

mapLinkStatus   OBJECT-TYPE
      SYNTAX  INTEGER
 {
 unknown(1),
 down(2),
 up(3)
 }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the status of the link between the
       two muxes"
::=  {agnLinkMapEntry 4}


--
-- diverseIfWanGen - diverse NON-DS1 interfaces of WAN products
--



--sonetInterface  OBJECT IDENTIFIER  ::=  {diverseIfWanGen 2}     (see radsonet.txt)
--ds3Interface    OBJECT IDENTIFIER  ::=  {diverseIfWanGen 3}	  (see radds3.txt)
--ds1Interface    OBJECT IDENTIFIER  ::=  {diverseIfWanGen 4}	  (see radds1.txt)
--hdlcMibObjects  OBJECT IDENTIFIER  ::=  {diverseIfWanGen 5}     (see radhdlc.txt)
--ip2If           OBJECT IDENTIFIER ::= { diverseIfWanGen 7 }	  (see ipmux.txt)


--
-- Wan alarm buffer (history) information
--
alrBufTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF AlrBufEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "A table."
	::=  { alrBuffGen 1 }

alrBufEntry OBJECT-TYPE
      SYNTAX AlrBufEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX { alrBufIdx }
      ::= { alrBufTable 1}

AlrBufEntry ::=
      SEQUENCE {
     alrBufIdx          Integer32,
     alrBufDescription  DisplayString,
     alrBufCode         Unsigned32,
     alrBufSlot 		INTEGER,
	 alrBufPort         Unsigned32,
	 alrBufSeverity     INTEGER,
	 alrBufState        INTEGER
      }

alrBufIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a  unique number to identify this
       entry"
    ::= { alrBufEntry 1}

alrBufDescription  OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..255))
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This entry is a unique text description of the alarm in the
       buffer.
       The alarm description includes the following information:
       alarm code, slot id, card type, channel id ,
       alarm text, alarm status, masked flag and event counter"
       ::= { alrBufEntry 2}

alrBufCode OBJECT-TYPE
      SYNTAX  Unsigned32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A code identifying the alarm of an entry in the alarm buffer
       table."
      ::= { alrBufEntry 3 }

alrBufSlot OBJECT-TYPE
      SYNTAX  INTEGER 
       {
       psA   (1),
       psB   (2),
       clA   (3),
       clB   (4),
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       notApplicable (255)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The slot number this alarm refers to.
       When the alarm refers to a system alarm, the value will be 'notApplicable(255)'."      
      ::= { alrBufEntry 4 }

alrBufPort OBJECT-TYPE
      SYNTAX  Unsigned32 
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The port number this alarm refers to.
       If the port number is irrelevant to this alarm (if it is
       a system/card level alarm) the value will be 9999."     
      ::= { alrBufEntry 5 }

alrBufSeverity OBJECT-TYPE
      SYNTAX  INTEGER
       {
       event    (3),
       minor    (4),
       major    (5),
       warning  (6),
       critical (7)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The severity of the alarm."
      ::= { alrBufEntry 6 }

alrBufState  OBJECT-TYPE
      SYNTAX  INTEGER
       {
       off(2),
       on (3)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "State of the alarm (On/Off)."
      ::= { alrBufEntry 7 }


alrBufferClearCmd OBJECT-TYPE
      SYNTAX  INTEGER
       {
      off(2),
      on (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Setting this attribute to ON, will enforce a  clear 
       operation on the Alarms Buffer. Upon completion, 
       the value will automatically change to off(2).
       For MP-2100/2200, this command will not really erase
       the Alarm Buffer, but is only an ACK of seeing the Buffer.
       It marks a pointer of the last entry's alrBufIdx, in order 
       to allow view of new alarms entered after this pointer
       (alrBufIdxUponLastAck)."
      ::= { alrBuffGen 2 }

alrBufIdxUponLastAck OBJECT-TYPE
      SYNTAX  Unsigned32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the value of alrBufIdx for the 
       last existing entry of alrBufTable, when alrBufferClearCmd
       was last Set to on(3).
       That will enable a user to see only Alarms that entered the 
       alrBufTable after last Set of alrBufferClearCmd, by GetNext 
       of alrBufDescription	with this index."
      ::= { alrBuffGen 3 }

--
-- Wan Flip Data-Base parameters
--
--         agnCAgendaTable :
--

agnCAgendaTable OBJECT-TYPE
      SYNTAX SEQUENCE OF AgnCAgendaEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
      "This table devides the week days into categories needed for
       DB flip consideration."
      ::= {agnFlipDb 1}

agnCAgendaEntry OBJECT-TYPE
      SYNTAX AgnCAgendaEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {agnCAgendaCnfgIdx, agnCAgendaDayIdx}
      ::= {agnCAgendaTable 1}

AgnCAgendaEntry ::=
      SEQUENCE {
           agnCAgendaCnfgIdx    INTEGER,
           agnCAgendaDayIdx           INTEGER,
           agnCAgendaDayCategory      INTEGER
               }

agnCAgendaCnfgIdx OBJECT-TYPE
      SYNTAX  INTEGER
              {
                active    (1),
                temporary  (255)
              }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Active or Temporary Agenda Table.
       Both configurations can be read but only the Temporary can
       be written to."
      ::= {agnCAgendaEntry 1}

agnCAgendaDayIdx OBJECT-TYPE
      SYNTAX  INTEGER
              {
                sunday    (1),
                monday    (2),
                tuesday   (3),
                wednesday (4),
                thursday  (5),
                friday    (6),
                saturday  (7)
              }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Day of week"
      ::= {agnCAgendaEntry 2}

agnCAgendaDayCategory OBJECT-TYPE
      SYNTAX  INTEGER
              {
                fullWorkday    (1),
                partialWorkday (2),
                weekend        (3)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The Category of the Day "
      ::= {agnCAgendaEntry 3}


--          agnCFlipNetEventsTable :
--

agnCFlipNetEventsTable OBJECT-TYPE
      SYNTAX SEQUENCE OF AgnCFlipNetEventsEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
      "This table holds the Net Events the MUX should trace"
      ::= {agnFlipDb 2}

agnCFlipNetEventsEntry OBJECT-TYPE
      SYNTAX AgnCFlipNetEventsEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {agnCFlipNetEventsCnfgIdx, agnCFlipNetEventIdx}
      ::= {agnCFlipNetEventsTable 1}

AgnCFlipNetEventsEntry ::=
      SEQUENCE {
    agnCFlipNetEventsCnfgIdx   INTEGER,
                agnCFlipNetEventIdx        Integer32,
                agnCFlipNetEventActive     INTEGER,
                agnCFlipNetEventType       INTEGER,
                agnCFlipNetEventNo         Integer32,
                agnCFlipNetEventSlot       INTEGER,
                agnCFlipNetEventPort       Integer32,
                agnCFlipNetEventISD        Integer32,
                agnCFlipNetEventOSD        Integer32,
                agnCFlipNetEventDayType    INTEGER,
                agnCFlipNetEventStartTime  DisplayString,
                agnCFlipNetEventEndTime    DisplayString
               }

agnCFlipNetEventsCnfgIdx OBJECT-TYPE
      SYNTAX  INTEGER
              {
                active    (1),
                temporary  (255)
              }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Active or Temporary Net Events Table.
       Both configurations can be read but only the Temporary can
       be written to."
      ::= {agnCFlipNetEventsEntry 1}

agnCFlipNetEventIdx OBJECT-TYPE
      SYNTAX  Integer32  (1..10)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Entry within the table"
      ::= {agnCFlipNetEventsEntry 2}

agnCFlipNetEventActive     OBJECT-TYPE
      SYNTAX  INTEGER
              {
                no  (2),
                yes (3)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Indicates if the entry is valid.
       In order to Add/Modify parameters of an entry, this object
       should be set to Yes.
       In order to delete an entry, this object should be Set to No."
      ::= {agnCFlipNetEventsEntry 3}


agnCFlipNetEventType OBJECT-TYPE
      SYNTAX  INTEGER
              {
                time       (1),
                linkDown   (2),
                congestion (3)   -- MP3000 Only
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The Net Event type "
      ::= {agnCFlipNetEventsEntry 4}

agnCFlipNetEventNo OBJECT-TYPE
      SYNTAX  Integer32  (1..512)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The Net Event No. (Bit Index)"
      ::= {agnCFlipNetEventsEntry 5}

agnCFlipNetEventSlot OBJECT-TYPE
      SYNTAX  INTEGER
              {
                notApplicable   (1),
                clA   (3),
                clB   (4),
                io1   (5),
                io2   (6),
                io3   (7),
                io4   (8),
                io5   (9),
                io6  (10),
                io7  (11),
                io8  (12),
                io9  (13),
                io10 (14),
                io11 (15),
                io12 (16)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The slot to which the net event relates .
       Not applicable for time event"
      ::= {agnCFlipNetEventsEntry 6}

agnCFlipNetEventPort OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The port within the relevant slot.
	   Valid values:
	   - extPrt1(1)..exPrt16(16) 
	   - notApplicable(100)
	   - inPrt1(101)..inPrt84(184)"
      ::= {agnCFlipNetEventsEntry 7}

agnCFlipNetEventISD OBJECT-TYPE
      SYNTAX  Integer32  (1..999)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The time in seconds since the Net Event was reported as ON
       until it is considered as ON.
       Not relevant for time events."
      ::= {agnCFlipNetEventsEntry 8}

agnCFlipNetEventOSD OBJECT-TYPE
      SYNTAX  Integer32  (1..999)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The time in seconds since the net event was reported as OFF
       until it is considered as OFF.
       Not relevant for time events."
      ::= {agnCFlipNetEventsEntry 9}

agnCFlipNetEventDayType OBJECT-TYPE
      SYNTAX  INTEGER
              {
                notApplicable  (1),
                fullWorkday    (2),
                partialWorkday (3),
    weekend        (4)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The time event relates to all days defined in this category in
       the agnCAgendaTable.
       Applicable only for time event"
      ::= {agnCFlipNetEventsEntry 10}

agnCFlipNetEventStartTime    OBJECT-TYPE
      SYNTAX    DisplayString (SIZE (5))
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The time event will be activated at this time.
       The format is hh:mm."
      ::= {agnCFlipNetEventsEntry 11}

agnCFlipNetEventEndTime     OBJECT-TYPE
      SYNTAX    DisplayString (SIZE (5))
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The time event will be deactivated at this time.
       The format is hh:mm."
      ::= {agnCFlipNetEventsEntry 12}


--         agnCFlipTable :
--

agnCFlipTable OBJECT-TYPE
     SYNTAX SEQUENCE OF AgnCFlipEntry
     MAX-ACCESS not-accessible
     STATUS  current
     DESCRIPTION
     "The DB Flip Decisions Table"
     ::= {agnFlipDb 3}

agnCFlipEntry OBJECT-TYPE
     SYNTAX AgnCFlipEntry
     MAX-ACCESS not-accessible
     STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {agnCFlipCnfgIdx, agnCFlipIdx}
     ::= {agnCFlipTable 1}

AgnCFlipEntry ::=
     SEQUENCE {
               agnCFlipCnfgIdx    INTEGER,
               agnCFlipIdx         Integer32,
               agnCFlipActive      INTEGER,
               agnCFlipLogicalExp  DisplayString,
               agnCFlipDbNo        Integer32,
               agnCFlipDiscardDe   INTEGER
              }

agnCFlipCnfgIdx OBJECT-TYPE
      SYNTAX  INTEGER
              {
                active     (1),
                temporary  (255)
              }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Active or Temporary Flip Decisions Table.
       Both configurations can be read but only the Temporary can
       be written to."
      ::= {agnCFlipEntry 1}



agnCFlipIdx OBJECT-TYPE
     SYNTAX  Integer32  (1..10)
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
     "Entry number within the table"
     ::= {agnCFlipEntry 2}

agnCFlipActive     OBJECT-TYPE
     SYNTAX  INTEGER
             {
               no  (2),
               yes (3)
             }
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
     "Indicates if the entry is valid.
      In order to Add/Modify parameters of an entry this object
      should be Set to Yes.
      In order to delete an entry, this object should be Set to No."
     ::= {agnCFlipEntry 3}

agnCFlipLogicalExp    OBJECT-TYPE
     SYNTAX    DisplayString (SIZE (1..20))
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
     "A logical expression composed of events numbers (which were
      configured in the 'AgnCFlipNetEvantsTable') and logical operators
      ('|', '&', '!', '(', ')') between them.
      e.g - (1 & !2) | (121 & 230)"
     ::= {agnCFlipEntry 4}

agnCFlipDbNo OBJECT-TYPE
     SYNTAX  Integer32  (1..10)
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
     "The ID of the required DB "
     ::= {agnCFlipEntry 5}

agnCFlipDiscardDe     OBJECT-TYPE
     SYNTAX  INTEGER
             {
               notApplicable (1),
               no            (2),
               yes           (3)
             }
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
     "Indicates whether the Mux should start discarding
      all DE. (MP3000 Only)."
     ::= {agnCFlipEntry 6}

--  Commands concerning the Flip DB

agnFlipDbControls    OBJECT IDENTIFIER ::= {agnFlipDb 4}


agnCFlipDbSanityCheckCmd OBJECT-TYPE
     SYNTAX  INTEGER
             {
               off(2),
               on (3)
             }
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
     "Setting this attribute to on(3) will initiate the process
      of Sanity check on the Temp Flip Db and automatically be
      changed to off(2)."
     ::= { agnFlipDbControls 1 }

agnCSaveFlipDbCmd OBJECT-TYPE
     SYNTAX  INTEGER
             {
               off(2),
               on (3)
             }
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
     "Setting this attribute to on(3) will initiate the process
      of Sanity check on the Temp Flip Db and if it is OK, it will
      save the Flip Db in the NVRAM, activating the new  Flip DB .
      If check detects errors, the save will not be performed.
      Afterwards, the object's value will change automatically to off(2)."
     ::= { agnFlipDbControls 2 }

agnCSaveNetCnfgIdxCmd OBJECT-TYPE
     SYNTAX  Integer32   (1..10)
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
     "This attribute specifies the Id of the target NVRAM Cnfg to
      which the TmpCnfg should be transferred. Upon set command the
      MUX will initiate the Sanity-Check  process first. If
      successful, the actual transfer will be performed. If warnings
      are detected, the user will have to perform the command again
      to confirm the operation. Setting this object a second time
      to the same value without performing any change in the database,
      will cause the result: agnSSanityCheckStatus = unknown.
      This attribute doesn't cause actual Flip."
     ::= { agnFlipDbControls 3 }

agnCSaveNetFlipDbCmd OBJECT-TYPE
     SYNTAX  INTEGER
             {
               off(2),
               on (3)
             }
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
     "Setting this attribute to on(3) will save the Temp Flip DB
      Into the NVRAM without actual flip."
     ::= { agnFlipDbControls 4 }

agnCNetGoCmd OBJECT-TYPE
     SYNTAX  INTEGER
             {
               off(2),
               on (3)
             }
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
     "Setting this attribute to On will broadcast a 'GO' command
      to the network.  When a Mux receives a 'GO' command it issues
      a delay for 'agnCNetDelay' seconds and then activates
      the DB which was pre-defined by one of the commands :
      'agnCSaveNetCnfgIdxCmd' or 'agnCSaveNetFlipDbCmd'."
     ::= { agnFlipDbControls 5 }

agnCNetDelay OBJECT-TYPE
     SYNTAX  Integer32 (1..999)
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
     "This attribute determines the period of time in seconds that
      takes for a message to be transferred over all the network.
      After a 'GO' command the MUX issues a delay of
      'agnCNetDelay' before activating the appropriate DB.
      The delay will be applied only after performing
      agnCSaveFlipDbCmd."
     ::= { agnFlipDbControls 6 }

agnCNetEventsBcast OBJECT-TYPE
     SYNTAX  INTEGER
             {
               disabled(2),
               enabled (3)
             }
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
     "This object determines if the Net Events will be Broadcasted to
      other Muxes of the Net or not.
      disabled - Net Events will NOT be Broadcasted
      enabled  - Net Events will be Broadcasted.
   Default=disabled.
      The value will be applied only after performing
      agnCSaveFlipDbCmd."
     ::= { agnFlipDbControls 7 }

agnCNetEventsBcastInterval OBJECT-TYPE
     SYNTAX  Integer32 (10..60)
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
     "When agnCNetEventsBcast is enabled, this object determines
      the interval of time in seconds, between two consecutive
      Net Events transferred over the network.
   Default=40 sec.
      The interval will be applied only after performing
      agnCSaveFlipDbCmd."
     ::= { agnFlipDbControls 8 }

--
-- agnSa = agent Stand-Alone (not HUB) specific objects
--
agnSaSwchStatus OBJECT-TYPE
     SYNTAX  Integer32
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
  "This object indicates the status of the switches on the
   stand-alone unit.
   Each switch is represented by a bit. The status is a sum of
   2**n, according to the bits:
   bit 0   NMS (LSB)
   bit 1   Terminal    '1' = forces the DCE to be terminal with
         Rate=9600bps, Data bits=8,
         Stop bits=1
   bit 2   Xray
   bit 3   SW-Load      '1' = when SW is loaded
   bit 4   DBS
   Default of all bits=0
   When the status of these switches is unknown, the value of
   this object is 255."
     ::= { agnSa 1 }

--Decoding Table: Code vs. Description

agnListDecodingTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF AgnListDecodingEntry
      MAX-ACCESS not-accessible
      STATUS  current
   DESCRIPTION
      "A decoding table . For each type of list, a description is
       given for each existing code."
      ::= { agnListDecoding 1 }

agnListDecodingEntry OBJECT-TYPE
      SYNTAX AgnListDecodingEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX { agnListDecodingType, agnListDecodingCode }
      ::= { agnListDecodingTable 1}

AgnListDecodingEntry ::=
      SEQUENCE {
     agnListDecodingType        INTEGER,
     agnListDecodingCode        Integer32,
     agnListDecodingDescription DisplayString,
     agnListDecodingDefState    INTEGER,
     agnListDecodingSeverity    INTEGER,
     agnListDecodingAcmRelaySlt INTEGER,
     agnListDecodingAcmRelayPrt INTEGER
      }

agnListDecodingType OBJECT-TYPE
      SYNTAX  INTEGER
       {
       alr      (1),
       sanity   (2),
       counter  (3)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The type of list the decoding data refers to.
       alr - Alarms list
       sanity - Sanity Check Error list.
       counter - Counter type of ifPerfCounterType "
      ::= { agnListDecodingEntry 1}

agnListDecodingCode OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The specific code for which decoding is needed. "
      ::= { agnListDecodingEntry 2}

agnListDecodingDescription OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..255))
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The description fitting the specific code and type of list
       required. "
      ::= { agnListDecodingEntry 3}

agnListDecodingDefState OBJECT-TYPE
      SYNTAX  INTEGER
       {
  notApplicable (1),
  event    (3),
  minor    (4),
  major    (5),
  warning  (6),
  critical (7)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object is applicable only for agnListDecodingType=alr.
       It reports the default state/severity of each alarm.
       User can change the  severity of the alarms defined by
       this default via the agnListDecodingSeverity object."
      ::= { agnListDecodingEntry 4}

agnListDecodingSeverity OBJECT-TYPE
      SYNTAX  INTEGER
       {
  notApplicable (1),
  event    (3),
  minor    (4),
  major    (5),
  warning  (6),
  critical (7)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object is applicable only for agnListDecodingType=alr.
       It enables the user to select a severity for each alarm.
    The severity is set per alarm code (same for all slots/ports
    using this code).
    event - can be set only for an alarm that is defined by
            default as 'event'.
       User can change the  severity of the alarms defined by
       default as minor or major.
       The severity of an event may be set to another severity,
       but the change will actually happen only if the event
       threshold is active and passed the Set/ON condition.
       An event alarm that passed the threshold and changed its
       severity, will return automatically to event severity when
       meeting its Reset/OFF condition."
      ::= { agnListDecodingEntry 5}

agnListDecodingAcmRelaySlt OBJECT-TYPE
      SYNTAX  INTEGER
     { none  (1),
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
	   notApplicable(255)
	    }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the ACM slot, desired for outbound relay
       (report) for the selected alarm.
       In the ?004 Unit the entries io6(10)..io12(16) are not valid.
	   none - when agnListDecodingType=alr AND the selected
                       alarm should not be reported by an ACM card.
       notApplicable - when agnListDecodingType=sanity OR when
             [agnListDecodingType=alr and there is no ACM card installed in the Mux]."
      ::= { agnListDecodingEntry 6}

agnListDecodingAcmRelayPrt OBJECT-TYPE
      SYNTAX  INTEGER
       {
      exPrt1    (1) ,
      exPrt2    (2) ,
      exPrt3    (3) ,
      exPrt4    (4) ,
      notApplicable(255)
	    }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the ACM port within the slot, desired for outbound relay
       (report) for the selected alarm.
       notApplicable - when agnListDecodingType=sanity OR when
                       agnListDecodingAcmRelaySlt=notApplicable."
      ::= { agnListDecodingEntry 7}


-- Dlci Table from system point of view
agnDlciTable  OBJECT-TYPE
     SYNTAX SEQUENCE OF AgnDlciEntry
     MAX-ACCESS not-accessible
     STATUS  current
     DESCRIPTION
      "The write operation into the Table Objects is valid only
       to the TmpCnfg entry."
     ::= { agnSystemDlci 1}

agnDlciEntry OBJECT-TYPE
      SYNTAX AgnDlciEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {agnDlciCnfgIdx, agnDlciLSltIdx, agnDlciLPrtIdx, agnDlciHIdx,
         agnDlciHSltIdx, agnDlciHPrtIdx, agnDlciLIdx }
      ::= { agnDlciTable 1}

AgnDlciEntry ::=
      SEQUENCE {
 	agnDlciCnfgIdx 	 Integer32,
 	agnDlciLSltIdx 	 INTEGER,
    agnDlciLPrtIdx	 Integer32,
    agnDlciLIdx		 Integer32,
	agnDlciHSltIdx	 INTEGER,
    agnDlciHPrtIdx	 Integer32,
    agnDlciHIdx		 Integer32,
	agnDlciTxBc	     INTEGER,
    agnDlciTxBe      INTEGER,
    agnDlciRxBc      INTEGER,
    agnDlciRxBe      INTEGER,
	agnDlciPriority  Integer32,
	agnDlciStatus    INTEGER,
	agnDlciSpoofing  INTEGER,
	agnDlciFunnelEnable INTEGER,
	agnDlciRoutingProtocol INTEGER,
	agnDlciRowStatus RowStatus
      }

agnDlciCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg. "
      ::= { agnDlciEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.

agnDlciLSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
     { cl(3),
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
	   vs  (254),
	   notApplicable(255)
	    }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted. This is the Source Slot of the DLCI.
	   vs=Voice Switching
       In the ?004 Unit the entries io6(10)..io16) are not valid.
       For ISDN BRI ports of MX300/30 units:
           io1(5) = isdn1(5) and io2(6) = isdn2(6)
       LSlotIdx is defined according one of the following possiblities:
 1. LSlotIdx is < HSlotIdx.
 2. LSlotIdx is = HSlotIdx and LPrtIdx is < HPrtIdx.
 3. LSlotIdx is = HSlotIdx and LPrtIdx is = HPrtIdx but LIdx is < HIdx."
      ::= { agnDlciEntry 2}

agnDlciLPrtIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique external or internal port number,
       including linkSelector or encapsulator. This is the Source Port of the DLCI.
	   100=noConnect  (for voice switching)
        LPrtIdx is defined according one of the following possiblities:
	1. LSlotIdx is < HSlotIdx.
	2. LSlotIdx is = HSlotIdx and LPrtIdx is < HPrtIdx.
	3. LSlotIdx is = HSlotIdx and LPrtIdx is = HPrtIdx but LIdx is < HIdx."
   ::= { agnDlciEntry 3}

agnDlciLIdx OBJECT-TYPE
      SYNTAX  Integer32 (0..991)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique index for each possible
       used DLCI(16..991). This is the Source Side of the DLCI.
       0=notApplicable (for voice switching)
       LIdx is defined according one of the following possiblities:
 1. LSlotIdx is < HSlotIdx.
 2. LSlotIdx is = HSlotIdx and LPrtIdx is < HPrtIdx.
 3. LSlotIdx is = HSlotIdx and LPrtIdx is = HPrtIdx but LIdx is < HIdx."
      ::= { agnDlciEntry 4}

agnDlciHSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
 {   cl    (3),
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
       notApplicable(255)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique slot position In the Mux
       where the DLCI is routed to - Destination Slot.
       For ISDN BRI ports of MX300/30 units:
           io1(5) = isdn1(5) and io2(6) = isdn2(6)
       In the ?004 Unit the entries io6(10)..io16) are not valid"
      ::= { agnDlciEntry 5}

agnDlciHPrtIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique port number where the DLCI is
       routed to - Destination Port."
      ::= { agnDlciEntry 6}

agnDlciHIdx OBJECT-TYPE
      SYNTAX  Integer32    (1..991)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique internal connection DLCI
       number where the Source DLCI is routed to - the Destination Side of the DLCI."
      ::= { agnDlciEntry 7}

agnDlciTxBc OBJECT-TYPE
      SYNTAX  INTEGER
        {
         full           (1),
         zero           (2),
         txBc5100bps    (3),
         txBc6400bps    (4),
         txBc8300bps    (5),
         txBc9600bps    (6),
        txBc14400bps    (7),
        txBc19200bps    (8),
        txBc28800bps    (9),
        txBc32000bps   (10),
        txBc38400bps   (11),
        txBc48000bps   (12),
        txBc56000bps   (13),
        txBc57600bps   (14),
          txBc64Kbps   (15),
         txBc128Kbps   (16),
         txBc192Kbps   (17),
         txBc256Kbps   (18),
         txBc320Kbps   (19),
         txBc384Kbps   (20),
         txBc448Kbps   (21),
         txBc512Kbps   (22),
         txBc768Kbps   (23),
         txBc896Kbps   (24),
        txBc1024Kbps   (25),
        txBc1152Kbps   (26),
        txBc1280Kbps   (27),
        txBc1344Kbps   (28),
        txBc1472Kbps   (29),
        txBc1600Kbps   (30),
        txBc1728Kbps   (31),
        txBc1856Kbps   (32),
        txBc1920Kbps   (33),
        txBc1984Kbps   (34),
        txBc2048Kbps   (35),
		txBc16000bps   (36), -- Added here: No room between (7) and (8).

		-- For Mx 30/300
		txBc112Kbps    (37),
		txBc168Kbps    (38),
        txBc224Kbps    (39),
		txBc336Kbps    (40),
        txBc672Kbps    (41),
        txBc1536Kbps   (42),
        txBc1792Kbps   (43)
        }
      MAX-ACCESS  read-create
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique Tx committed bandwidth on
       the user transmit line or at the port receive line."
      DEFVAL { full }
      ::= { agnDlciEntry 8}

agnDlciTxBe OBJECT-TYPE
      SYNTAX  INTEGER
        {
         full           (1),
         zero           (2),
         txBe5100bps    (3),
         txBe6400bps    (4),
         txBe8300bps    (5),
         txBe9600bps    (6),
        txBe14400bps    (7),
        txBe19200bps    (8),
        txBe28800bps    (9),
        txBe32000bps   (10),
        txBe38400bps   (11),
        txBe48000bps   (12),
        txBe56000bps   (13),
        txBe57600bps   (14),
          txBe64Kbps   (15),
         txBe128Kbps   (16),
         txBe192Kbps   (17),
         txBe256Kbps   (18),
         txBe320Kbps   (19),
         txBe384Kbps   (20),
         txBe448Kbps   (21),
         txBe512Kbps   (22),
         txBe768Kbps   (23),
         txBe896Kbps   (24),
        txBe1024Kbps   (25),
        txBe1152Kbps   (26),
        txBe1280Kbps   (27),
        txBe1344Kbps   (28),
        txBe1472Kbps   (29),
        txBe1600Kbps   (30),
        txBe1728Kbps   (31),
        txBe1856Kbps   (32),
        txBe1920Kbps   (33),
        txBe1984Kbps   (34),
        txBe2048Kbps   (35),
		txBe16000bps   (36), -- Added here: No room between (7) and (8).

		-- For Mx 30/300
		txBe112Kbps    (37),
		txBe168Kbps    (38),
        txBe224Kbps    (39),
		txBe336Kbps    (40),
        txBe672Kbps    (41),
        txBe1536Kbps   (42),
        txBe1792Kbps   (43)
        }
      MAX-ACCESS  read-create
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique Tx excess bandwidth on the
      user transmit line or at the port receive line."
      DEFVAL { zero }
      ::= { agnDlciEntry 9}

agnDlciRxBc OBJECT-TYPE
      SYNTAX  INTEGER
        {
         full           (1),
         zero           (2),
         rxBc5100bps    (3),
         rxBc6400bps    (4),
         rxBc8300bps    (5),
         rxBc9600bps    (6),
        rxBc14400bps    (7),
        rxBc19200bps    (8),
        rxBc28800bps    (9),
        rxBc32000bps   (10),
        rxBc38400bps   (11),
        rxBc48000bps   (12),
        rxBc56000bps   (13),
        rxBc57600bps   (14),
          rxBc64Kbps   (15),
         rxBc128Kbps   (16),
         rxBc192Kbps   (17),
         rxBc256Kbps   (18),
         rxBc320Kbps   (19),
         rxBc384Kbps   (20),
         rxBc448Kbps   (21),
         rxBc512Kbps   (22),
         rxBc768Kbps   (23),
         rxBc896Kbps   (24),
        rxBc1024Kbps   (25),
        rxBc1152Kbps   (26),
        rxBc1280Kbps   (27),
        rxBc1344Kbps   (28),
        rxBc1472Kbps   (29),
        rxBc1600Kbps   (30),
        rxBc1728Kbps   (31),
        rxBc1856Kbps   (32),
        rxBc1920Kbps   (33),
        rxBc1984Kbps   (34),
        rxBc2048Kbps   (35),
		rxBc16000bps   (36), -- Added here: No room between (7) and (8).

				-- For Mx 30/300
		rxBc112Kbps    (37),
		rxBc168Kbps    (38),
        rxBc224Kbps    (39),
		rxBc336Kbps    (40),
        rxBc672Kbps    (41),
        rxBc1536Kbps   (42),
        rxBc1792Kbps   (43)
        }
      MAX-ACCESS  read-create
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique Rx committed bandwidth on
       the user receive line or at the port transmit line."
      DEFVAL { full }
      ::= { agnDlciEntry 10}

agnDlciRxBe OBJECT-TYPE
      SYNTAX  INTEGER
        {
         full           (1),
         zero           (2),
         rxBe5100bps    (3),
         rxBe6400bps    (4),
         rxBe8300bps    (5),
         rxBe9600bps    (6),
        rxBe14400bps    (7),
        rxBe19200bps    (8),
        rxBe28800bps    (9),
        rxBe32000bps   (10),
        rxBe38400bps   (11),
        rxBe48000bps   (12),
        rxBe56000bps   (13),
        rxBe57600bps   (14),
          rxBe64Kbps   (15),
         rxBe128Kbps   (16),
         rxBe192Kbps   (17),
         rxBe256Kbps   (18),
         rxBe320Kbps   (19),
         rxBe384Kbps   (20),
         rxBe448Kbps   (21),
         rxBe512Kbps   (22),
         rxBe768Kbps   (23),
         rxBe896Kbps   (24),
        rxBe1024Kbps   (25),
        rxBe1152Kbps   (26),
        rxBe1280Kbps   (27),
        rxBe1344Kbps   (28),
        rxBe1472Kbps   (29),
        rxBe1600Kbps   (30),
        rxBe1728Kbps   (31),
        rxBe1856Kbps   (32),
        rxBe1920Kbps   (33),
        rxBe1984Kbps   (34),
        rxBe2048Kbps   (35),
		rxBe16000bps   (36), -- Added here: No room between (7) and (8).

		-- For Mx 30/300
		rxBe112Kbps    (37),
		rxBe168Kbps    (38),
        rxBe224Kbps    (39),
		rxBe336Kbps    (40),
        rxBe672Kbps    (41),
        rxBe1536Kbps   (42),
        rxBe1792Kbps   (43)
		}
      MAX-ACCESS  read-create
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique Rx excess bandwidth on the
      user receive line or at the port transmit line."
      DEFVAL { zero }
      ::= { agnDlciEntry 11}

agnDlciPriority OBJECT-TYPE
      SYNTAX  Integer32  (1..8)
      MAX-ACCESS  read-create
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique priority of the pcv.
       1 is the lowest priority and 7 is the highest priority."
      ::= { agnDlciEntry 12}

agnDlciStatus OBJECT-TYPE
      SYNTAX  INTEGER
 {
          disconnected (1),
          connected    (2)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the status of the pvc. The status is
       disconnected(1) when one of the sides is programmed as
       not connected"
      ::= { agnDlciEntry 13}

agnDlciSpoofing OBJECT-TYPE
      SYNTAX  INTEGER
      {   no     (2),
          yes    (3)
	      }
      MAX-ACCESS  read-create
      STATUS  current
      DESCRIPTION
      "This object refers to sending of RIP messages:
       - yes : RIP messages will be sent ONLY if there is a change in the Net.
	   - no  : RIP messages will be always sent.
	   This object is relevant only when one side of the DLCI is a CL-NMS interface.
	   Default=no. "
      ::= { agnDlciEntry 14}

agnDlciFunnelEnable OBJECT-TYPE
      SYNTAX  INTEGER
      {   disabled    (2),
          enabled     (3),
		  source      (4),
		  destination (5)
	      }
      MAX-ACCESS  read-create
      STATUS  current
      DESCRIPTION
      "This object selects Funnel activation:

       - disabled:   Funnel operation will be disabled.
                     The agnDlciTxBe and agnDlciTxBc values are not used for funneling.
	   - enabled :   Funnel operation will be enabled both for Source and Destination
	                 of the DLCI. The agnDlciTxBe and agnDlciTxBc values are used
	                 for funneling calculations.
	   - source:     Funnel operation will be enabled only for the Source of the DLCI.
	   - destination:Funnel operation will be enabled only for the Destination of the DLCI.
	   
	   This object is relevant only for an encapsulating DLCI.

	   In case of a Link Selector DLCI, the agnDlciTxBe and agnDlciTxBc
	               values are used for bandwidth of Link Selector.
	   Default=disabled. "
      ::= { agnDlciEntry 15}

agnDlciRoutingProtocol OBJECT-TYPE
      SYNTAX  INTEGER
      {   notApplicable(1),
          rip (2),
          rip2(3),
          none(4)
	      }
      MAX-ACCESS  read-create
      STATUS  current
      DESCRIPTION
      "This object is relevant only when one side of the DLCI is a CL-NMS interface.
	   It defines which Routing Protocol will be used for management via CL-NMS port.
	   notApplicable will be used for all slots but CL.
	   rip is a proprietary rip protocol.

	   Default=rip. "
      ::= { agnDlciEntry 16}

agnDlciRowStatus OBJECT-TYPE
      SYNTAX  RowStatus
      MAX-ACCESS  read-create
      STATUS  current
      DESCRIPTION
      "This attribute allows to create/delete a row in this table.
       For creating a row, the NMS should set
	   agnRowStatus.255.id2.id3.id4.id5.id6.id7 = active(1).
       For destroying a row, the NMS should set:
	   agnRowStatus.255.id2.id3.id4.id5.id6.id7 = destroy(6).
       Only rows with status active(1) are relevant.
       The only possible supported RowStatus vaules are
       active (1) and destroy (6)."
      ::= { agnDlciEntry 17}


-- Voice Switching Configuration Support: agnVoiceSwitching group
agnVoiceSwConfTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF AgnVoiceSwConfEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
      "MXcess Configuration for Voice Switching."
     ::= { agnVoiceSwitching 1 }

agnVoiceSwConfEntry OBJECT-TYPE
      SYNTAX AgnVoiceSwConfEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX { agnVoiceSwConfIdx }
      ::= { agnVoiceSwConfTable 1}

AgnVoiceSwConfEntry ::=
      SEQUENCE {
 agnVoiceSwConfIdx INTEGER,
 agnVoiceSwConfZoneId  DisplayString,
 agnVoiceSwConfNodeId  DisplayString,
 agnVoiceSwConfNoOfHops 	Integer32,
 agnVoiceSwConfSidt         Integer32,
 agnVoiceSwConfLidt         Integer32,
 agnVoiceSwConfDialPlan		INTEGER 
	}

agnVoiceSwConfIdx OBJECT-TYPE
      SYNTAX  INTEGER {    active(1),  temporary(255)  }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Active or Temporary Table.
       Both configurations can be read but only the Temporary can
       be written to."
      ::= { agnVoiceSwConfEntry 1}

agnVoiceSwConfZoneId OBJECT-TYPE
      SYNTAX  DisplayString(SIZE(1..2))
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "1 or 2 digits, (0-9)(1-9)."
      ::= { agnVoiceSwConfEntry 2}

agnVoiceSwConfNodeId OBJECT-TYPE
      SYNTAX  DisplayString(SIZE(1..3))
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "1, 2 or 3 digits, (1-9),(0-9),(0-9)."
      ::= { agnVoiceSwConfEntry 3}

agnVoiceSwConfNoOfHops OBJECT-TYPE
      SYNTAX  Integer32 (0..20)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Number of hops the frame will go through the net before deciding to discard
       the frame (like time-to-live in IP).

       0 = notApplicable
       Default=20 ."
      ::= { agnVoiceSwConfEntry 4}

agnVoiceSwConfSidt OBJECT-TYPE
      SYNTAX  Integer32 (0..30)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "SIDT: Short Inter Digit Timeout used as timer (in sec.) between digits
       after routing is completed.
       The timeout indicates end of dialing and the call can then be setup.

       0 = notApplicable
       Default=2 sec."
      ::= { agnVoiceSwConfEntry 5}

agnVoiceSwConfLidt OBJECT-TYPE
      SYNTAX  Integer32 (0..30)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "LIDT: Long Inter Digit Timeout used as timer between digits before routing
       is completed. If no digits were dialed and LIDT expired then the user will get
       an error tone and the call will be disconnected.

       0 = notApplicable
       Default=15 sec."
      ::= { agnVoiceSwConfEntry 6}

agnVoiceSwConfDialPlan OBJECT-TYPE
      SYNTAX  INTEGER {
	   staticDialPlan(2),
	   staticDialPlanPlus(3),
	   flexDialPlan(4)
 	   }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This is the Dialing Plan method that will be used in the Voice Switching.
      Static Dialing Plan - Routing is defined by the current device Zone and
                            Node ID in the Network.
      Static Dialing Plan Plus - Includes the Static Dialing Plan but contains an
                            addition of defining the number of dialed digits.
      Flexible Dialing Plan - Routing is defined in a flexible form.
                              In this plan the user can configure the extension number
                              of a local voice channel, Route a call to a remote
                              destination and enter the Number of Digits for a specific
                              dial prefix."
      ::= { agnVoiceSwConfEntry 7}


agnVoiceSwConfRtTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF AgnVoiceSwConfRtEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
      "Routing Table for Voice Switching."
     ::= { agnVoiceSwitching 2 }

agnVoiceSwConfRtEntry OBJECT-TYPE
      SYNTAX AgnVoiceSwConfRtEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX { agnVoiceSwConfRtDbId, agnVoiceSwConfRtIdx }
      ::= { agnVoiceSwConfRtTable 1}

AgnVoiceSwConfRtEntry ::=
      SEQUENCE {
 agnVoiceSwConfRtDbId   INTEGER,
 agnVoiceSwConfRtIdx        Integer32,
 agnVoiceSwConfRtDigits  DisplayString,
 agnVoiceSwConfRtAction  INTEGER,
 agnVoiceSwConfRtData  DisplayString,
 agnVoiceSwConfRtSlot  INTEGER,
 agnVoiceSwConfRtPort  Integer32,
 agnVoiceSwConfRtDlci  Integer32,
 agnVoiceSwConfRtRowStatus RowStatus,
 agnVoiceSwConfRtMaxCalls  Integer32,
 agnVoiceSwConfRtPriority  Integer32 
	}

agnVoiceSwConfRtDbId OBJECT-TYPE
      SYNTAX  INTEGER {    active(1),  temporary(255)  }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Active or Temporary Table.
       Both configurations can be read but only the Temporary can
       be written to."
 ::= { agnVoiceSwConfRtEntry 1 }

agnVoiceSwConfRtIdx  OBJECT-TYPE
 SYNTAX  Integer32
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 " The Index of the row."
 ::= { agnVoiceSwConfRtEntry 2 }

agnVoiceSwConfRtDigits OBJECT-TYPE
 SYNTAX  DisplayString ( SIZE(1..7) )
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 " Dialed digits: Series of digits 0...9, '*', '#' or '%'.
   The '*' and '#' can have many uses according to the user's decision.
   For example, they can be used as part of the Dialed Number,
   they exist on the phone number panel.
   '*' can also be used instead of a series of numbers.
   The '%' means any digits (wildcard) and is used without a series of digits.
 
   When the agnVoiceSwConfRtAction is del (7), the series of digits that
   are configured via this MIB object will be deleted from the prefix of
   the dialed number."
 ::= { agnVoiceSwConfRtEntry 3 }

agnVoiceSwConfRtAction OBJECT-TYPE
 SYNTAX  INTEGER {
   notApplicable(1),
   zone(2),
   node(3),
   shortDialing(4), 
   in(5),  -- Internal switching
   hgr(6), -- Hunt Group
   del(7), -- Delete a prefix from the Dialed Number
   rep(8), -- Replace a prefix with a given string of digits
   pri(9), -- for ISDN
   bri(10),-- for ISDN
   numDigDP(11), -- Number of Digits user will dial according to Dialing Plan.
   route(12), -- Route to a Remote Destination
   ext(13) -- Extension to a local voice channel
 }
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 " Action that the system should perform for the digits:
   agnVoiceSwConfRtDigits.
   The action that is allowed depends on the Dialing Plan.
   Here is the list of the allowed actions:
   For Static Dialing Plan - zone, node, in, shortDialing, hgr, del, rep
   For Static Dialing Plan Plus - zone, node, in, shortDialing, hgr, del, rep, numDigDP
   For Flexible Dialing Plan - hgr, del, rep, numDigDP, route, ext"
 DEFVAL { notApplicable }
 ::= { agnVoiceSwConfRtEntry 4 }

agnVoiceSwConfRtData   OBJECT-TYPE
 SYNTAX  DisplayString(SIZE(1..7))
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 " This field is relevant for actions hgr(6), and rep(8), numDigDP(11)
   and contains the following information:
   For hgr - the number of the Hunt Group.
   For rep - the number of digits to be replaced with.
   For numDigDP - the number of digits collected before establishing the call.
                  0 indicates no defined length. In this case SIDT will be used."
-- DEFVAL {"0" }
 ::= { agnVoiceSwConfRtEntry 5 }

agnVoiceSwConfRtSlot OBJECT-TYPE
 SYNTAX  INTEGER{
       noConnect(2),
       cl    (3),
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
       notApplicable(255)
       }
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 " Routing Slot- Relevant for actions zone(2), node(3), shortDialing(4),
   route(12), ext(13)."
 DEFVAL { noConnect }
 ::= { agnVoiceSwConfRtEntry 6 }

agnVoiceSwConfRtPort OBJECT-TYPE
 SYNTAX  Integer32
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
	" Routing Port- Relevant for actions zone(2), node(3), shortDialing(4),
      route(12), ext(13).
	  100=noConnect (for non-routing case)."
 DEFVAL { 0 }
 ::= { agnVoiceSwConfRtEntry 7 }

agnVoiceSwConfRtDlci OBJECT-TYPE
	SYNTAX 	Integer32
	MAX-ACCESS	read-create
	STATUS	current
	DESCRIPTION
	" Routing DLCI- Relevant for actions zone(2), node(3), shortDialing(4),
      route(12), ext(13). 
	  Valid values:
	  0=notApplicable (for non-routing case).
	  1, 16..991 "
    DEFVAL { 15 }
	::= { agnVoiceSwConfRtEntry 8 }

agnVoiceSwConfRtRowStatus OBJECT-TYPE
 SYNTAX  RowStatus
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 " Status of the row for creating/deleting entries in the table.
   The only possible supported RowStatus vaules are
   active (1), notInService (2), notReady(3), createAndGo(4),
   createAndWait(5) and destroy(6)."
 ::= { agnVoiceSwConfRtEntry 9 }

agnVoiceSwConfRtMaxCalls OBJECT-TYPE
      SYNTAX  Integer32 
      MAX-ACCESS  read-create
      STATUS  current
      DESCRIPTION
      "Maximum no. of simultaneous voice calls that are allowed in the direction
       defined by the current entry.

       Default=0 (No Limit)."
      ::= { agnVoiceSwConfRtEntry 10}

agnVoiceSwConfRtPriority OBJECT-TYPE
      SYNTAX  Integer32 
      MAX-ACCESS  read-create
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique priority of the Voice Switching Route.
       1 is the lowest priority and 7 is the highest priority.
	   0 means N/A "       
      ::= { agnVoiceSwConfRtEntry 11}


agnVoiceSwConfHGTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF AgnVoiceSwConfHGEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
      "Table of Hunt Groups."
     ::= { agnVoiceSwitching 5 }

agnVoiceSwConfHGEntry OBJECT-TYPE
      SYNTAX AgnVoiceSwConfHGEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX { agnVoiceSwConfHGdbIdx, agnVoiceSwConfHGIdx }
      ::= { agnVoiceSwConfHGTable 1}

AgnVoiceSwConfHGEntry ::=
      SEQUENCE {
 		agnVoiceSwConfHGdbIdx			INTEGER,
 		agnVoiceSwConfHGIdx				Integer32,
 		agnVoiceSwConfHGConnect			INTEGER,
 		agnVoiceSwConfHGExt				Integer32,
		agnVoiceSwConfHGExtString		SnmpAdminString,
		agnVoiceSwConfHGUserParams		SnmpAdminString,
		agnVoiceSwConfHGStatus			INTEGER
		}

agnVoiceSwConfHGdbIdx OBJECT-TYPE
      SYNTAX  INTEGER {    active(1),  temporary(255)  }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Active or Temporary Table.
       Both configurations can be read but only the Temporary can
       be written to."
      ::= { agnVoiceSwConfHGEntry 1}

agnVoiceSwConfHGIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "For Vmux-300 devices -
	   This object represents a combination of
	   - Hunt Group number and Extension number OR
	   - Port number and Extension number.

       For other devices (e.g. MXcess, MP-2100H) -
       There may be up to 10 Hunt Groups per MXcess. That's the
       index of the hunt group relevant to this row."
      ::= { agnVoiceSwConfHGEntry 2}

agnVoiceSwConfHGConnect OBJECT-TYPE
      SYNTAX  INTEGER {  no(2),  yes(3)   }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the  hunt group  should be
       considered in any of the mux algorithms."
      ::= { agnVoiceSwConfHGEntry 3}

 agnVoiceSwConfHGExt OBJECT-TYPE
      SYNTAX  Integer32(0..99)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This is the extension number of the hunt group.
       0 is for not valid. The allowed range is 10 - 99."
      DEFVAL { 0 }
      ::= { agnVoiceSwConfHGEntry 4}

 agnVoiceSwConfHGExtString OBJECT-TYPE
      SYNTAX		SnmpAdminString
      MAX-ACCESS	read-write
      STATUS		current
      DESCRIPTION
      "This is the extension string of the hunt group.
	   This string is a combination of digits, * and #."
      ::= { agnVoiceSwConfHGEntry 5}

 agnVoiceSwConfHGUserParams OBJECT-TYPE
      SYNTAX		SnmpAdminString
      MAX-ACCESS	read-write
      STATUS		current
      DESCRIPTION
      "This object indicates the User's parameters."
      ::= { agnVoiceSwConfHGEntry 6}

 agnVoiceSwConfHGStatus OBJECT-TYPE
      SYNTAX		INTEGER
	  {
		active			(1),
		notInService	(2),
		notReady	 	(3),
		createAndGo		(4),
		createAndWait	(5),
		destroy			(6),
		notApplicable	(255)
	  }
      MAX-ACCESS	read-write
      STATUS		current
      DESCRIPTION
	  "This object enables the user to create/delete entries in this table.
	   Its usage for values (1)..(6) should be identical to RowStatus SYNTAX.
	   notApplicable(255) - should be used when the table is static
	                        (i.e. whenever create/delete entries is not allowed)."
      ::= { agnVoiceSwConfHGEntry 7}

--
-- Signaling Profiles for MP-2200 and MP-2100
--
-- Legacy Profile Table

agnSigProfileTable  OBJECT-TYPE
     SYNTAX SEQUENCE OF AgnSigProfileEntry
     MAX-ACCESS not-accessible
     STATUS  current
     DESCRIPTION
      "- For products supporting more than one configuration, the write operation 
          into the Table is valid only to the TmpCnfg entry.
        - For products that do not support configurations, the write operation 
          into the Table will be to agnSigProfileCnfgIdx=1.
       The table includes signaling profile parameters for Legacy Profiles."
     ::= { agnSigProfile 1}

agnSigProfileEntry OBJECT-TYPE
      SYNTAX AgnSigProfileEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {agnSigProfileCnfgIdx, agnSigProfileIdx, agnSigProfileRxTx}
      ::= { agnSigProfileTable 1}

AgnSigProfileEntry ::=
      SEQUENCE {
      agnSigProfileCnfgIdx       Integer32,
      agnSigProfileIdx           Integer32,
      agnSigProfileRxTx          INTEGER,
      agnSigProfileABCD          OCTET STRING,
	  agnSigProfileEcanActSignal INTEGER,
	  agnSigProfileEcanRespDelay Unsigned32
      }

agnSigProfileCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32 
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg.
       For products supporting more than one configuration,the write 
       operation is valid only to the TmpCnfg.
       For Gmux2000 the range limitation (1..255) was discarded
       since the Idx is computed as: <IO Card No.> x 1000 + 255."
      ::= { agnSigProfileEntry 1}

agnSigProfileIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..5)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Signaling Profile (1..5).
       For MP-104/204, only Profile=1 will exist."
      ::= { agnSigProfileEntry 2}

agnSigProfileRxTx OBJECT-TYPE
      SYNTAX  INTEGER
       {
       rx   (1),
       tx   (2)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates if the following objects refer to:
       Rx or Tx translation.
       Rx : ML->IO
       Tx : IO->ML  .
       For MP-104/204, that means:
       Rx : Signaling to FXS CH
       Tx : Signaling to E1 Link. "
      ::= { agnSigProfileEntry 3}

agnSigProfileABCD OBJECT-TYPE
      SYNTAX  OCTET STRING
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "For MP-2100/MP-2200 and for MP-104/204 from R2:
       This object represents 6 parameters, by 3 Octets :
       Busy  Code-MSB nibble, - applicable only for Rx translation
       Idle  Code-    nibble, - applicable only for Rx translation
       D Bit Code-    nibble,
       C Bit Code-    nibble,
       B Bit Code-    nibble,
       A Bit Code-LSB nibble.

       Each of Busy and Idle Code nibble will have the valid values:
       0000 .. FFFF.

       Each of A,B,C,D Bit Code nibble represents:
       0 hex = 0000 = 0
       1 hex = 0001 = 1
       2 hex = 0010 = A bit
       3 hex = 0011 = B bit
       4 hex = 0100 = C bit
       5 hex = 0101 = D bit
       6 hex = 0110 = A bit inverse
       7 hex = 0111 = B bit inverse
       8 hex = 1000 = C bit inverse
       9 hex = 1001 = D bit inverse
       A-F hex - not used (invalid values)

       For MP-104/204 R1:
	   This object represents 3 parameters, by 2 Octets :
       Bit  1 = Bit A - OFF Hook for Tx	; Ring for Rx (LSB)
	   Bit  2 = Bit B - OFF Hook for Tx	; Ring for Rx 
	   Bit  3 = Bit C - OFF Hook for Tx	; Ring for Rx 
	   Bit  4 = Bit D - OFF Hook for Tx	; Ring for Rx 
	   Bit  5 = Bit A - ON  Hook for Tx ; Idle for Rx
	   Bit  6 = Bit B - ON  Hook for Tx ; Idle for Rx
	   Bit  7 = Bit C - ON  Hook for Tx ; Idle for Rx
	   Bit  8 = Bit D - ON  Hook for Tx ; Idle for Rx

	   Bit  9 = Bit A - OOS State for both Tx and Rx
	   Bit 10 = Bit B - OOS State for both Tx and Rx 
	   Bit 11 = Bit C - OOS State for both Tx and Rx 
	   Bit 12 = Bit D - OOS State for both Tx and Rx 
	   Bit 13 = Spare (always 0)
	   Bit 14 = Spare (always 0)
	   Bit 15 = Spare (always 0)
	   Bit 16 = Spare (always 0)  (MSB)

       When the object is not applicable, the Octet String will have 0 bytes."
      ::= { agnSigProfileEntry 4}

agnSigProfileEcanActSignal OBJECT-TYPE
      SYNTAX  INTEGER 
       {
          notApplicable (1),
          aBit1         (2),
          aBit0         (3),
		  bBit1         (4),
		  bBit0         (5),
		  cBit1         (6),
		  cBit0         (7),
		  dBit1         (8),
		  dBit0         (9)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Echo Canceller Activation Signal.
       This object specifies which BIT (A, B, C, or D) and which value (0 or 1)
       will be used for the echo canceller activation. The inverse value will cause the
       deactivation of the echo canceller."
      ::= { agnSigProfileEntry 5}
 
agnSigProfileEcanRespDelay OBJECT-TYPE
      SYNTAX  Unsigned32 
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Echo Canceller Response Delay.
       This object specifies the response delay in msec for the activation/deactivation
       of the echo canceller.
       The value should be in multiples of 100 msec: 100, 200, 300, ...2000."
      ::= { agnSigProfileEntry 6}


-- General Profile Table

agnSigProfTable  OBJECT-TYPE
     SYNTAX SEQUENCE OF AgnSigProfEntry
     MAX-ACCESS not-accessible
     STATUS  current
     DESCRIPTION
      "The write operation into the Table Objects is valid only
       to the TmpCnfg entry. This is the general table of signaling profiles."
     ::= { agnSigProfile 2}

agnSigProfEntry OBJECT-TYPE
      SYNTAX AgnSigProfEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {agnSigProfCnfgIdx, agnSigProfIdx}
      ::= { agnSigProfTable 1}

AgnSigProfEntry ::=
      SEQUENCE {
      agnSigProfCnfgIdx       Integer32,
      agnSigProfIdx           Integer32,
      agnSigProfName          DisplayString,
	  agnSigProfType          INTEGER
      }

agnSigProfCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg.
       The write operation is valid only to the TmpCnfg."
      ::= { agnSigProfEntry 1}

agnSigProfIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..5)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Signaling Profile (1..5)."
      ::= { agnSigProfEntry 2}

agnSigProfName   OBJECT-TYPE
      SYNTAX  DisplayString(SIZE(0..12))
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
      "Profile Name given by user."
      ::= { agnSigProfEntry 3 }

agnSigProfType OBJECT-TYPE
      SYNTAX  INTEGER 
       {
          notApplicable (1),
          legacy        (2),
          r2Cas         (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Profile Type.
       legacy - usual signaling. The parameters for the Legacy Profiles 
                are detailed in the agnSigProfileTable, above.
       r2Cas  - R2 signaling. The parameters for the R2 Profiles are detailed
                in the r2 ProfileCnfg tables (belong to r2If).   "
      ::= { agnSigProfEntry 4 }


--
-- TS Assignment Table from system point of view
--
-- agnTsTable  OBJECT-TYPE ::= { agnSystemTs 1}
--
-- For this table see tsa.txt file.


-- General System Voice parameters
--
systemVoiceTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF SystemVoiceEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
      "General Parameters for voice - system level."
     ::= { systemVoice 1 }

systemVoiceEntry OBJECT-TYPE
      SYNTAX SystemVoiceEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX { systemVoiceConfIdx }
      ::= { systemVoiceTable 1}

SystemVoiceEntry ::=
      SEQUENCE {
 			systemVoiceConfIdx					Integer32,
 			systemVoiceNationalTone 			INTEGER,
 			systemVoicePacketRate				Unsigned32,
			systemVoiceFaxSupport				INTEGER,
			systemVoiceFaxRate					INTEGER,
			systemVoiceModemSupport				INTEGER,
			systemVoiceCoderAndRate				INTEGER,
			systemVoiceEchoCanceler				INTEGER,
			systemVoiceTxGain					Integer32,
			systemVoiceDtmfRelayMethod			INTEGER,
			systemVoiceDtmfRelayRxPayloadType	Unsigned32,
			systemVoiceDtmfRelayPayloadTypeNeg	INTEGER,
			systemVoiceDtmfRelayTxPayloadType	Unsigned32
 	  }

systemVoiceConfIdx OBJECT-TYPE
      SYNTAX  Integer32 
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed - Active or Temporary Configurations.
       Idx  255 relates to the temporary TmpCnfg.
       All configurations can be read but only the Temporary can
       be written to."
      ::= { systemVoiceEntry 1}

systemVoiceNationalTone OBJECT-TYPE
      SYNTAX  INTEGER 
       {
          notApplicable (1),
          usa           (2),
          australia     (3),
		  brazil        (4),
		  canada        (5),
		  france        (6),
		  germany       (7),
		  israel        (8),
		  mexico        (9),
		  portugal      (10),
		  russia        (11),
		  spain         (12),
		  unitedKingdom (13),
		  czech         (14),
  		  china         (15)  
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Tone Characteristics (Amplitude, Frequency, delays etc.).
       These characteristics are defined according to the country."
      ::= { systemVoiceEntry 2}

systemVoicePacketRate OBJECT-TYPE
      SYNTAX		Unsigned32
      MAX-ACCESS	read-write
      STATUS		current
      DESCRIPTION
      "This object indicates the G.729 and G.711 Coders
       transmitted Packet Rate in milliseconds."
      ::= { systemVoiceEntry 3}

systemVoiceFaxSupport OBJECT-TYPE
      SYNTAX		INTEGER 
      {
			notApplicable   (1),
			disable			(2),
			faxRelayT38		(3),
			vbdPassThrou	(4)
      }
      MAX-ACCESS	read-write
      STATUS		current
      DESCRIPTION
      "This object allows the user to Disable/Enable Fax support."
      ::= { systemVoiceEntry 4}

systemVoiceFaxRate OBJECT-TYPE
      SYNTAX		INTEGER 
      {
			notConnected	(1),
			r4800bps		(2),
			-- reserved for r7200bps		(3)
			r9600bps		(4),
			-- reserved for r12000bps		(5)
			r14400bps		(6)
      }
      MAX-ACCESS	read-write
      STATUS		current
      DESCRIPTION
      "This object indicates the Fax Rate limit.
       It is irrelevant when Fax support is NA or disabled."
      ::= { systemVoiceEntry 5}

systemVoiceModemSupport OBJECT-TYPE
      SYNTAX		INTEGER 
      {
			notApplicable   (1),
			disable			(2),
			vbdV152			(3),
			vbdPassThrou	(4)
      }
      MAX-ACCESS	read-write
      STATUS		current
      DESCRIPTION
      "This object allows the user to Disable/Enable Modem support."
      ::= { systemVoiceEntry 6}

systemVoiceCoderAndRate OBJECT-TYPE
      SYNTAX		INTEGER 
      {
			notApplicable   (1),
			-- reserved for g7231r6300BPS	(2)
			-- reserved for g7231r5300BPS	(3)
			-- reserved for g729A8KBPS		(4)
			g711aLAW        (5),
			g711uLAW        (6)
      }
      MAX-ACCESS	read-write
      STATUS		current
      DESCRIPTION
      "This object indicates the Coder and Rate for the Voice Compression."
      ::= { systemVoiceEntry 7}

systemVoiceEchoCanceler OBJECT-TYPE
      SYNTAX		INTEGER 
      {
			notApplicable	(1),
			disable			(2),
			enable			(3)
      }
      MAX-ACCESS	read-write
      STATUS		current
      DESCRIPTION
      "This object indicates the Echo Canceler activation."
      ::= { systemVoiceEntry 8}

systemVoiceTxGain OBJECT-TYPE
      SYNTAX		Integer32
      MAX-ACCESS	read-write
      STATUS		current
      DESCRIPTION
      "This object indicates the Transmit Gain (volume) in dB."
      ::= { systemVoiceEntry 9}

systemVoiceDtmfRelayMethod OBJECT-TYPE
      SYNTAX		INTEGER 
      {
			rfc2833			(1),
			sipInfo			(2)
      }
      MAX-ACCESS	read-write
      STATUS		current
      DESCRIPTION
      "This object indicates the DTMF Relay Method
       that is used to transmit DTMF tones.
       
       rfc2833(1) - inband DTMF relay according to RFC-2833.
       sipInfo(2) - out of band DTMF relay using SIP INFO method."
      ::= { systemVoiceEntry 10}

systemVoiceDtmfRelayRxPayloadType OBJECT-TYPE
      SYNTAX		Unsigned32
      MAX-ACCESS	read-write
      STATUS		current
      DESCRIPTION
      "This object indicates the Rx Payload Type
       for DTMF relay RTP packets.
       It is relevant only when DTMF Relay Method is RFC-2833."
      ::= { systemVoiceEntry 11}

systemVoiceDtmfRelayPayloadTypeNeg OBJECT-TYPE
      SYNTAX		INTEGER 
      {
			notApplicable	(1),
			disable			(2),
			enable			(3)
      }
      MAX-ACCESS	read-write
      STATUS		current
      DESCRIPTION
      "This object indicates whether Payload Type Negotiation is used
       (according to RFC-2833) or not.
       It is relevant only when DTMF Relay Method is RFC-2833."
      ::= { systemVoiceEntry 12}

systemVoiceDtmfRelayTxPayloadType OBJECT-TYPE
      SYNTAX		Unsigned32
      MAX-ACCESS	read-write
      STATUS		current
      DESCRIPTION
      "This object indicates the Tx Payload Type
       for DTMF relay RTP packets.
       It is relevant only when the Payload Type Negotiation is disabled."
      ::= { systemVoiceEntry 13}


systemVoiceCoderTable  OBJECT-TYPE
      SYNTAX		SEQUENCE OF SystemVoiceCoderEntry
      MAX-ACCESS	not-accessible
      STATUS		current
      DESCRIPTION
      "Voice Coders table."
     ::= { systemVoice 2 }

systemVoiceCoderEntry OBJECT-TYPE
      SYNTAX		SystemVoiceCoderEntry
      MAX-ACCESS	not-accessible
      STATUS		current
	  DESCRIPTION  "An entry in Voice Coders table."
	  INDEX { systemVoiceCoderConfIdx, systemVoiceCoderPriority }
      ::= { systemVoiceCoderTable 1}

SystemVoiceCoderEntry ::=
      SEQUENCE {
 			systemVoiceCoderConfIdx      	Unsigned32,
 			systemVoiceCoderPriority		Unsigned32,
			systemVoiceCoderCoderAndRate	INTEGER
 	  }

systemVoiceCoderConfIdx OBJECT-TYPE
      SYNTAX		Unsigned32 
      MAX-ACCESS	not-accessible
      STATUS		current
      DESCRIPTION
	"The first index of the table.
	 
	 This object might represent the Configuration Index (1..100) being accessed;
	 Index=255 relates to the TmpCnfg.
	 For devices with multiple configurations, Set is permitted to TmpCnfg(255) only.
	 
	 Not-Applicable = 1."
      ::= { systemVoiceCoderEntry 1}

systemVoiceCoderPriority OBJECT-TYPE
      SYNTAX		Unsigned32 
      MAX-ACCESS	not-accessible
      STATUS		current
      DESCRIPTION
      "This object indicates the Coder's Priority."
      ::= { systemVoiceCoderEntry 2}

systemVoiceCoderCoderAndRate OBJECT-TYPE
      SYNTAX		INTEGER
      {
			notApplicable		(1),
			g7231r6300BPS		(2),
			g7231r5300BPS		(3),
			g729A8KBPS			(4),
			g711aLAW			(5),
			g711uLAW			(6),
			none				(255)
      }
      MAX-ACCESS	read-write
      STATUS		current
      DESCRIPTION
      "This object indicates the Coder and Rate for the Voice Compression."
      ::= { systemVoiceCoderEntry 3}


--
-- Wan installed module status general information
--
mdlSInstTable  OBJECT-TYPE
    SYNTAX SEQUENCE OF MdlSInstEntry
    MAX-ACCESS not-accessible
    STATUS current
	DESCRIPTION  "A table."
	::=  { statMdlGen 1 }

mdlSInstEntry OBJECT-TYPE
    SYNTAX MdlSInstEntry
    MAX-ACCESS not-accessible
    STATUS current
	DESCRIPTION  "An entry in table."
	INDEX { mdlSInstSltIdx }
      ::= { mdlSInstTable 1}

MdlSInstEntry ::=
      SEQUENCE {
     mdlSInstSltIdx        INTEGER,
     mdlSInstCardType      INTEGER,
     mdlSHwVersion         DisplayString,
     mdlSSwVersion         DisplayString,
     mdlSAlrStatus         INTEGER,
     mdlSAlrStatusAll      INTEGER,
     mdlSMaskedAlrStat     INTEGER,
     mdlSMaskedAlrStatAll  INTEGER,
     mdlSTstStatusAll      INTEGER,
     mdlSClearAlrCmd       INTEGER,
     mdlSClearAllAlrCmd    INTEGER,
	 mdlSTemperature       Integer32
      }

mdlSInstSltIdx OBJECT-TYPE
   SYNTAX  INTEGER
   {
       psA   (1),
       psB   (2),
       clA   (3),
       clB   (4),
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
   }
   MAX-ACCESS  read-only
   STATUS  current
   DESCRIPTION
   "A unique number to identify a slot position in the mux.
    In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io(16)
    are not valid.
    For the Vmux2100 Main Board clA  (3) is used."
   ::= { mdlSInstEntry 1}

mdlSInstCardType OBJECT-TYPE
   SYNTAX  INTEGER
   {
  --
  -- General types
  --		 
         unknown        (1),
         empty          (2),

  -- (3)..(7) are reserved ; they appear in the compress structure

		 acm            (9), --alarm module
  --
  -- Power Supply Modules
  --
        ps60W          (10),
        ps100W         (11),
   -- (12)..(16) are reserved for the Programmed PS cards
		ps             (17), 

  --
  -- Cl Modules
  --
        cl1            (20),
        clEth          (21),
        cl2            (22),
		cl2Eth         (23),
        cl3            (24),
		cl3Eth         (25),
		cl1Clk         (26), --CL1 with Station Clock (for LRS102)
  --
  -- Packet Cards of Megaplex
  --
        mPh1            (31),
        mPh3            (32),
        mPh1T1DSU       (33),
        mPh1T1CSU       (34),
        mPh1E1DSU       (35),
        mPh1E1LTU       (36),

  -- TDM Cards

        mtmlFT1         (37),
        mtmlFE1         (38),
		mtmlH4E1        (39),
		mtmlH4E12W      (40),
		mtmlH4T1        (41),
		mtmlH4T12W      (42),
		mtHsh4E1        (43),
		mtHsh4E12W      (44),
		mtHsh4T1        (45),
		mtHsh4T12W      (46),
		mtmlH2E1        (47),
		mtmlH2E12W      (48),
		mtmlH2T1        (49),
		mtmlH2T12W      (50),
		hsh2E1          (51),
		hsh2E12W        (52),
		hsh2T1          (53),
		hsh2T12W        (54),
		mlIp            (55),
		mtml4Ip         (56),
		ml20N1          (57),
		ml20N2          (58),

  -- Packet Cards of Megaplex

        mPl6            (60),
        mPl3            (61),

  -- VF cards of Megaplex
        vf24T1          (62),
		vf30E1          (63),
		vf48T1          (64),
		vf60E1          (65),

  -- Vmux-2100 Main Link cards 
	    ml2E1           (68),
	    ml4E1           (69),
        ml2T1           (70),
	    ml4T1           (71),

        mPv4            (72), 
  --
  -- TDM Cards
  --
      vc16A             (73),
      vc8EandM          (74),
      vc8Fxo            (75),
      vc8Fxs            (76),
      vc16EandM         (77),
      vc16Fxo           (78),
      vc16Fxs           (79),

      vf3EandM          (80),
      vf3Fxs            (81),
      vf3Fxo            (82),

      vfPbx             (83),
      vfPbxT1           (84),
      vfPbxE1           (85),

	  mtMlE2S           (86), --Single Link
	  mtMlE2D           (87), --Dual Link 
      mtMlF2T1          (88),
      mtMlF2E1          (89),
      mtMlT1Fiber       (90),
      mtMlE1Fiber       (91),
      mtMlT1FiberFb     (92),
      mtMlE1FiberFb     (93),
      mtmlHE1           (94),
      mtmlH1E1          (95),
      mtmlHSE1          (96),
      ml20              (97),
      mtMl4T1           (98),
      mtMl4E1           (99),

      mtMl1T1DSU       (100),
      mtMl1T1CSU       (101),
      mtMl1E1DSU       (102),
      mtMl1E1LTU       (103),
      mtMl1T1DSUfb     (104),
      mtMl1T1CSUfb     (105),
      mtMl1E1DSUfb     (106),
      mtMl1E1LTUfb     (107),
      mtMl2T1          (108),
      mtMl2E1          (109),

       ls2CcittX50     (110),
       ls2CcittX58     (111),
       ls2ATandTSdm    (112),
       ls2ACcittX50    (113),
       ls2ACcittX58    (114),
       ls2AATandTSdm   (115),
       ls2A2Ts         (116),
       ls2M            (117),

      mtMlT1           (118),
      mtMlE1           (119),

       hs2             (120),
       hs3             (121),
       hsq             (122),
       hs703           (123),
       hsQM            (124),
       hsqN            (125),
       hs6             (126),
       hs12            (127),
	   hsDp            (128),
	   hsp             (129), 

       hs4T1           (130),
       hs4E1           (131),
       hs4             (132),
       hsEth           (133),

	   ml8T1           (134),
	   ml8E1           (135),     

  --  Vmux-2100  Voice cards 
       vc2E1           (136),
       vc4E1           (137),
       vc2T1           (138),
       vc4T1           (139), 

       vc2EandM        (140),
       vc2Fxs1Plar     (141),
       vc2Fxo1         (142),
       vc2Fxs2         (143),
       vc2Fxo2         (144),
       vc2Fxs3         (145),
       vc2Fxo3         (146),
       vc26EandM       (147),
       mtvc2           (148),
       vc2R2Fxs        (149),

       hsu             (150),

       mbeA            (151),
       mbeB            (152),
       mbeU            (153),
       tre             (154),

       hsuI            (155),
       hsr             (156),
       hss             (157),
       hsu1            (158),

       ls12            (159),
       ls6             (160),
       ls6V1EandM      (161),
       ls6V1Fxo        (162),
       ls6V1Fxs        (163),
       ls6V2EandM      (164),
       ls6V2Fxo        (165),
       ls6V2Fxs        (166),
       ls6VfEandM      (167),
       ls6VfFxo        (168),
       ls6VfFxs        (169),

       vc3EandM        (170),
       vc3Fxo          (171),
       vc3Fxs          (172),

       vcPbx           (173),
       vcPbxT1         (174),
       vcPbxE1         (175),

       vc6EandM        (176),
       vc6Fxo          (177),
       vc6Fxs          (178),

       vcq             (179),

       ls6n            (180),

  --
  -- Packet Cards of MAXcess and Hybrid
  --

        -- High speed cards

        mhs1V36          (181),
        mhs1V35          (182),
        mhs1G703         (183),
        mhs1DDS          (184),
        mhs3             (185),
        mhs1X21          (186),
        mhs1V24          (187),
		mhs4             (188),
        mhsE1Hs          (189),
		mhsT1Hs          (190),
		mhsHyE1Hs        (191), -- 2 HS ports + 1 Hybrid E1 port
		mhsHyT1Hs        (192), -- 2 HS ports + 1 Hybrid T1 port
        mlfHybE1Hs       (193), -- Fiber Optic Hybrid: 2 HS + 1 Hybrid E1 port
        mlfHybT1Hs       (194), -- Fiber Optic Hybrid: 2 HS + 1 Hybrid T1 port 

        -- T1/E1 cards

        mhs2e1			 (195),
		mhs2t1           (196),
		mhsHy2e1         (197), -- 2 Hybrid E1 ports
		mhsHy2t1         (198), -- 2 Hybrid T1 ports
        mlfHybE12        (199), -- Fiber Optic Hybrid: 2 E1 ports
   

        -- Low speed cards

        mls6             (200),
        mls3             (201),


        -- More  T1/E1 cards

        mlHybAtmE1       (202), -- Hybrid ATM E1
        mlHybAtmT1       (203), -- Hybrid ATM T1
        mlfHybT12        (204), -- Fiber Optic Hybrid: 2 T1 ports


		--  Voice cards

        mvc8             (205), -- MVC-8 name in marketing: MVC-4N
        mvc8PbxE1        (206),
        mvc8PbxT1Dsu     (207),
        mvc8PbxT1Csu     (208),
        mvc8PbxE1Slave   (209),

        mvc4             (210),
        mvc4PbxE1        (211),
        mvc4PbxT1Dsu     (212),
        mvc4PbxT1Csu     (213),
        mvc4PbxE1Slave   (214),
        mvc4PbxT1Slave   (215),
 
        mvc8PbxT1Slave   (216),	-- MVC-8 T1 Slave is here
        mvc8ExtAnalog    (217), -- MVC-8 with 8 External ports
		mvcE1            (218), -- 8 External ports & 30 Internals
		mvcT1            (219), -- 8 External ports & 24 Internals

		-- ISDN for Maxcess
        mhsS             (220),
        mhsU             (221),
        mhsPriE1         (222),
        mhsPriT1         (223),

        --Card of MP-2100/4
        hsEthSwitch      (224),

        -- CCS for Maxcess & MPH
        mPriE1FramerCcs  (225),
        mPriT1FramerCcs  (226),
        mPriE1SlaveCcs   (227),
        mPriT1SlaveCcs   (228),
		mDualBri         (229),

        --Voice cards for MP
        vc12EandM        (230),
        vc12Fxo          (231),
        vc12Fxs          (232),
		vc6aEandM        (233),
        vc6aFxo          (234),
        vc6aFxs          (235),
        vc6AgFxo         (236),
        vc6AgFxs         (237),
        vc6a4LB          (238),

        --Video card for MP
		vid              (239),

        --ISDN cards for MP
		hsu12            (240),
		hsu6             (241),
		hss12            (242),
		hss6             (243),

        -- MPH and MP-2100/4 cards
        hsDp3			 (244),	  
        hsDp6			 (245),	  

        -- MP-2100/4 card
        hsf1             (246),

        -- More Hybrid cards + IP cards for MPH
    	mhsHyE1          (247),   -- 1 Hybrid E1 port
		mhsHyT1          (248),   -- 1 Hybrid T1 port         
        mhsIp            (249),   -- 1 Eth  port + 1 HS port
        mlIpHs           (250),   -- 1 Eth  port + 3 HS ports
        mlHybIpE1        (251),   -- 1 Eth  port + 1 HS port + 1 E1
        mlHybIpT1        (252),   -- 1 Eth  port + 1 HS port + 1 T1

        -- VOIP cards for MPH & MX
        mvg1Lan          (253),
        mvg2Lan          (254),

        -- MP-2100/4 card
        vc4Fxs           (255),
		vc4EandM         (256),
		vc4Fxo           (257),
        hsf2             (258),

        -- More VOIP cards for MPH
        mvgSwitch4Lan    (260),

        --SHDSL cards of Megaplex
        msl4E1W2         (261),
		msl4E1W4         (262),
		msl8E1W2         (263),
        msl4E1W2Eth      (264),
		msl8E1W2Eth      (265),
		asmi54cE1AndEth  (266), -- & LRS-102 (E1 & ETH)
		asmi54cT1AndEth  (267), -- & LRS-102 (T1 & ETH)
		asmi54c          (268), -- & LRS-102 (ETH only)

        --HS cards of Megaplex
		hs6N             (271),
		hs12N            (272),
		hsNRZ            (273),

       -- Vmux 2100 Enhanced Voice Cards
	   evc2E1            (281),
	   evc4E1            (282),
	   evc2T1            (283),
	   evc4T1            (284),

   --  Vmux-2200  Voice cards 
       vc2E1Pri          (285),
       vc4E1Pri          (286),

   --  MP Voice cards
       vc4OmniEandM      (291),
       vc4OmniWestern    (292),
       
   --  MP-4100 and/or LRS-102 cards
       clx1              (301),
       clx1GbE           (302),
       clx1S155          (303),
       clx1S155GbE       (304),
       ml8T1Eth          (305),
       ml8E1Eth          (306),
	   op106cEth         (307),	--no external T1
	   op108cEth         (308),	--no external E1
	   op106cEthT1       (309), --with external T1 (used also by LRS-102)
	   op108cEthE1       (310), --with external E1 (used also by LRS-102)
	   op108cEthE1Unbal  (311),	--used only by LRS-102
	   mpw1              (312),
       
  -- VFS cards of Megaplex
        vfs24T1          (321),
		vfs30E1          (322),
		vfs48T1          (323),	 --2T1
		vfs60E1          (324),  --2E1

-- MiniCVS cards
        mm4E1            (325),
        mm4T1            (326),
        mm8E1            (327),
        mm8T1            (328),
        mm12E1           (329),
        mm12T1           (330),
        mm16E1           (331),
        mm16T1           (332)
     }
   MAX-ACCESS  read-only
   STATUS  current
   DESCRIPTION
   "This attribute indicates the type of card installed
    in the specific slot position.
    Only PS cards are possible in the PS slots.
    Only CL cards are possible in the CL slots.
    Only IO cards are possible in the IO slots."
   ::= { mdlSInstEntry 2}

mdlSHwVersion OBJECT-TYPE
   SYNTAX  DisplayString (SIZE (0..255))
   MAX-ACCESS  read-only
   STATUS  current
   DESCRIPTION
   "This attribute indicates the Hardware version of the
    installed card in the specific slot position."
   ::= { mdlSInstEntry 3 }

mdlSSwVersion OBJECT-TYPE
   SYNTAX  DisplayString (SIZE (0..255))
   MAX-ACCESS  read-only
   STATUS  current
   DESCRIPTION
   "This attribute indicates the Software version of the
    installed card in the specific slot position."
   ::= {mdlSInstEntry 4}

mdlSAlrStatus OBJECT-TYPE
  SYNTAX  INTEGER
  {
  off      (2),
  event    (3),
  minor    (4),
  major    (5),
  warning  (6),
  critical (7)
  }
  MAX-ACCESS  read-only
  STATUS  current
  DESCRIPTION
  "Indicates the alarm state at module level, i.e. lower level
  (port alarms) status is not included.
  This attribute will be set to:
    critical(7) - when there is at least one active (state ON)
                  critical alarm,
                  otherwise it will be set to
       major(5) - when there is at least one active (state ON)
                  major alarm,
                  otherwise it will be set to
       minor(4) - if there is at least one active (state ON) minor
                  alarm,
                  otherwise it will be set to
       warning(6) - if there is at least one active (state ON)
                  warning alarm,
                  otherwise it will be set to
       event(3) - if there was at least one alarm event (including
                  state on,off events) since the last clear operation."
   ::= { mdlSInstEntry 5 }

mdlSAlrStatusAll OBJECT-TYPE
  SYNTAX  INTEGER
  {
  off      (2),
  event    (3),
  minor    (4),
  major    (5),
  warning  (6),
  critical (7)
  }
  MAX-ACCESS  read-only
  STATUS  current
  DESCRIPTION
  "Indicates the alarm state in the module-all level, i.e. lower level
  (port alarms) included.
  This attribute will be set to:
    critical(7) - when there is at least one active (state ON)
                  critical alarm,
                  otherwise it will be set to
       major(5) - when there is at least one active (state ON)
                  major alarm,
                  otherwise it will be set to
       minor(4) - if there is at least one active (state ON) minor
                  alarm,
                  otherwise it will be set to
       warning(6) - if there is at least one active (state ON)
                  warning alarm,
                  otherwise it will be set to
       event(3) - if there was at least one alarm event (including
                  state on,off events) since the last clear operation."
   ::= { mdlSInstEntry 6 }

mdlSMaskedAlrStat OBJECT-TYPE
  SYNTAX  INTEGER
  {
  off      (2),
  event    (3),
  minor    (4),
  major    (5),
  warning  (6),
  critical (7)
  }
  MAX-ACCESS  read-only
  STATUS  current
  DESCRIPTION
  "Indicates the alarm state at module level, [i.e. lower level
  (port alarms) status is not included],including Masked alarms.
  This attribute will be set to:
    critical(7) - when there is at least one active (state ON)
                  critical alarm,
                  otherwise it will be set to
       major(5) - when there is at least one active (state ON)
                  major alarm,
                  otherwise it will be set to
       minor(4) - if there is at least one active (state ON) minor
                  alarm,
                  otherwise it will be set to
       warning(6) - if there is at least one active (state ON)
                  warning alarm,
                  otherwise it will be set to
       event(3) - if there was at least one alarm event (including
                  state on,off events) since the last clear operation."
  ::= { mdlSInstEntry 7 }

mdlSMaskedAlrStatAll OBJECT-TYPE
  SYNTAX  INTEGER
  {
  off      (2),
  event    (3),
  minor    (4),
  major    (5),
  warning  (6),
  critical (7)
  }
  MAX-ACCESS  read-only
  STATUS  current
  DESCRIPTION
  "Indicates the alarm state in the module-all level, i.e. lower level
  (port alarms) included, including Masked alarms.
  This attribute will be set to:
    critical(7) - when there is at least one active (state ON)
                  critical alarm,
                  otherwise it will be set to
       major(5) - when there is at least one active (state ON)
                  major alarm,
                  otherwise it will be set to
       minor(4) - if there is at least one active (state ON) minor
                  alarm,
                  otherwise it will be set to
       warning(6) - if there is at least one active (state ON)
                  warning alarm,
                  otherwise it will be set to
       event(3) - if there was at least one alarm event (including
                  state on,off events) since the last clear operation."
  ::= { mdlSInstEntry 8 }

mdlSTstStatusAll OBJECT-TYPE
  SYNTAX  INTEGER
  {
  off(2),
  on (3)
  }
  MAX-ACCESS  read-only
  STATUS  current
  DESCRIPTION
  "This attribute will be set to on(3) when there is at least
   one test in progress on a channel of the card, otherwise
   the value will be off(2)."
  ::= { mdlSInstEntry 9 }

mdlSClearAlrCmd  OBJECT-TYPE
  SYNTAX  INTEGER
  {
  off(2),
  on (3)
  }
  MAX-ACCESS  read-write
  STATUS  current
  DESCRIPTION
  "Setting this command to ON, enforces a clear of all the
   alarms in the given slot, excluding alarms of port level.
   The clear operation will not be applied for masked/inverted
   alarms."
  ::= { mdlSInstEntry 10 }

mdlSClearAllAlrCmd  OBJECT-TYPE
  SYNTAX  INTEGER
  {
  off(2),
  on (3)
  }
  MAX-ACCESS  read-write
  STATUS  current
  DESCRIPTION
  "Setting this command to ON, enforces a  clear of all the
   alarms in the given slot, including all its ports alarms.
   The clear operation will not be applied for masked/inverted
   alarms."
  ::= { mdlSInstEntry 11 }

mdlSTemperature OBJECT-TYPE
  SYNTAX  Integer32
  MAX-ACCESS  read-only
  STATUS  current
  DESCRIPTION
  "Temperature of the card, in Celsius degrees."
  ::= { mdlSInstEntry 12 }


mdlSAlrTable OBJECT-TYPE
      SYNTAX SEQUENCE OF MdlSAlrEntry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
      "The list of card agent alarms ; includes also an alarm
       indicating existence of alarms on its ports if there are any."
      ::= { statMdlGen 2 }

mdlSAlrEntry OBJECT-TYPE
      SYNTAX MdlSAlrEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {mdlSAlrSltIdx , mdlSAlrIdx}
      ::= { mdlSAlrTable 1}

MdlSAlrEntry ::=
      SEQUENCE {
  mdlSAlrSltIdx           INTEGER,
  mdlSAlrIdx              Integer32,
  mdlSAlrCodeDescription  DisplayString,
  mdlSAlrCode             Integer32,
  mdlSAlrSeverity         INTEGER,
  mdlSAlrState            INTEGER,
  mdlSAlrCounter          Integer32,
  mdlSAlrMask             INTEGER,
  mdlSAlrInvert           INTEGER
      }

mdlSAlrIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A unique number to identify an entry in the alarm status table.
       Users should use the get next function to read this table because
       the indexes are not consecutive."
      ::= { mdlSAlrEntry 1}

mdlSAlrSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
       {
       psA   (1),
       psB   (2),
       clA   (3),
       clB   (4),
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the  desired slot position.
       In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io12(16)
       are not valid.
       For the Vmux2100 Main Board clA  (3) is used."
      ::= { mdlSAlrEntry 2}

mdlSAlrCodeDescription OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..255))
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute is a full text description of the alarm .
       The alarm description includes the following information:
       alarm code, alarm text, alarm severity, Masked or Inverted
       flag and counter."
      ::= { mdlSAlrEntry 3}

mdlSAlrCode OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A code identifying the alarm of an entry in the alarm status
       table at card level."
      ::= { mdlSAlrEntry 4 }

mdlSAlrSeverity OBJECT-TYPE
      SYNTAX  INTEGER
       {
  event    (3),
  minor    (4),
  major    (5),
  warning  (6),
  critical (7)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The severity of the alarm."
      ::= { mdlSAlrEntry 5 }

mdlSAlrState  OBJECT-TYPE
      SYNTAX  INTEGER
       {
  off(2),
  on (3)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "State of the alarm."
      ::= { mdlSAlrEntry 6 }

mdlSAlrCounter OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A counter - how many times the alarm occured since last
       clear operation.
       ON and OFF Alarm will be counted separately."
      ::= { mdlSAlrEntry 7 }

mdlSAlrMask  OBJECT-TYPE
      SYNTAX  INTEGER
       {
  off(2),
  on (3)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Alarm mask : on/off."
      ::= { mdlSAlrEntry 8 }

mdlSAlrInvert  OBJECT-TYPE
      SYNTAX  INTEGER
       {
  off(2),
  on (3)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Alarm invert : on/off."
      ::= { mdlSAlrEntry 9 }


--
-- Wan module configuration information
--
mdlCPrgTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF MdlCPrgEntry
      MAX-ACCESS not-accessible
      STATUS current
    DESCRIPTION  "A table."
    ::=  { cnfgMdlGen 1 }

mdlCPrgEntry OBJECT-TYPE
      SYNTAX MdlCPrgEntry
      MAX-ACCESS not-accessible
      STATUS current
    DESCRIPTION  "An entry in table."
    INDEX { mdlCCnfgIdx, mdlCSltIdx  }
      ::= { mdlCPrgTable 1}

MdlCPrgEntry ::= SEQUENCE {
    mdlCCnfgIdx             Integer32,
    mdlCSltIdx              INTEGER,
    mdlCPrgCardType         INTEGER,
   		mdlCNoOfExternPrt     Integer32,   -- RO
   		mdlCNoOfInternPrt     Integer32,   -- RO
		mdlCWorkMode          INTEGER,
		mdlCDhcpClientEnable  INTEGER,
		mdlCRdnExists         INTEGER,	   -- RO
		mdlCInterfaces        OCTET STRING
 }

mdlCCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg(1..100) being
       referred.
       Value  255 specifies the TmpCnfg "
      ::= { mdlCPrgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.

mdlCSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
       {
       psA   (1),
       psB   (2),
       clA   (3),
       clB   (4),
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique number of  the slot
       position where the card is inserted.
       In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16)
       are not valid."
      ::= { mdlCPrgEntry 2}

mdlCPrgCardType OBJECT-TYPE
      SYNTAX  INTEGER
       {
--
-- General types
--
        unknown         (1),
        empty           (2),

    -- (3)..(7) are reserved ; they appear in the compress structure

         acm            (9), --alarm module

--
-- Power Supply Modules
--
        ps48x60W       (10),
        ps48x100W      (11),
        ps110x60W      (12),
        ps110x100W     (13),
        ps220x60W      (14),
        ps220x100W     (15),
        ps180W         (16),
        ps             (17), 

--
-- Cl Modules
--
        cl1            (20),
        clEth          (21),
        cl2            (22),
        cl2Eth         (23),
        cl3            (24),
        cl3Eth         (25),
        cl1Clk         (26), --CL1 with Station Clock (for LRS102)
--
-- Packet Cards of Megaplex
--
        mPh1           (31),
        mPh3           (32),
        mPh1T1DSU      (33),
        mPh1T1CSU      (34),
        mPh1E1DSU      (35),
        mPh1E1LTU      (36),

-- TDM Cards

        mtmlFT1        (37),
        mtmlFE1        (38),
        mtmlH4E1       (39),
        mtmlH4E12W     (40),
        mtmlH4T1       (41),
        mtmlH4T12W     (42),
        mtHsh4E1       (43),
        mtHsh4E12W     (44),
        mtHsh4T1       (45),
        mtHsh4T12W     (46),
        mtmlH2E1       (47),
        mtmlH2E12W     (48),
        mtmlH2T1       (49),
        mtmlH2T12W     (50),
        hsh2E1         (51),
        hsh2E12W       (52),
        hsh2T1         (53),
        hsh2T12W       (54),
        mlIp           (55),
        mtml4Ip        (56),
        ml20N1         (57),
        ml20N2         (58),

-- Packet Cards of Megaplex

        mPl6           (60),
--      mPl3           (61),

-- VF cards of Megaplex
        vf24T1         (62),
        vf30E1         (63),
        vf48T1         (64),
        vf60E1         (65),

-- Vmux-2100 Main Link cards 
        ml2E1          (68),
        ml4E1          (69),
        ml2T1          (70),
        ml4T1          (71),

--      mPv4           (72),

--
-- TDM Cards
--
        vc16A          (73),
        vc8EandM       (74),
        vc8Fxo         (75),
        vc8Fxs         (76),
        vc16EandM      (77),
        vc16Fxo        (78),
        vc16Fxs        (79),

        vf3EandM       (80),
        vf3Fxs         (81),
        vf3Fxo         (82),

        vfPbx          (83),
        vfPbxT1        (84),
        vfPbxE1        (85),

        mtMlE2S        (86), --Single Link
        mtMlE2D        (87), --Dual Link 
        mtMlF2T1       (88),
        mtMlF2E1       (89),
        mtMlT1Fiber    (90),
        mtMlE1Fiber    (91),
        mtMlT1FiberFb  (92),
        mtMlE1FiberFb  (93),
        mtmlHE1        (94),
        mtmlH1E1       (95),
        mtmlHSE1       (96),
        ml20           (97),
        mtMl4T1        (98),
        mtMl4E1        (99),

        mtMl1T1DSU     (100),
        mtMl1T1CSU     (101),
        mtMl1E1DSU     (102),
        mtMl1E1LTU     (103),
        mtMl1T1DSUfb   (104),
        mtMl1T1CSUfb   (105),
        mtMl1E1DSUfb   (106),
        mtMl1E1LTUfb   (107),
        mtMl2T1        (108),
        mtMl2E1        (109),

        ls2CcittX50    (110),
        ls2CcittX58    (111),
        ls2ATandTSdm   (112),
        ls2ACcittX50   (113),
        ls2ACcittX58   (114),
        ls2AATandTSdm  (115),
        ls2A2Ts        (116),
        ls2M           (117),

        mtMlT1         (118),
        mtMlE1         (119),

        hs2            (120),
        hs3            (121),
        hsq            (122),
        hs703          (123),
        hsQM           (124),
        hsqN           (125),
        hs6            (126),
        hs12           (127),
        hsDp           (128), 
        hsp            (129), 

        hs4T1          (130),
        hs4E1          (131),
--      hs4            (132),
        hsEth          (133),

        ml8T1          (134),
        ml8E1          (135),     

--  Vmux-2100  Voice cards 
        vc2E1          (136),
        vc4E1          (137),
        vc2T1          (138),
        vc4T1          (139),

        vc2EandM       (140),
        vc2Fxs1Plar    (141),
        vc2Fxo1        (142),
        vc2Fxs2        (143),
        vc2Fxo2        (144),
        vc2Fxs3        (145),
        vc2Fxo3        (146),
        vc26EandM      (147),
        mtvc2          (148),
        vc2R2Fxs       (149),

        hsu            (150),

        mbeA           (151),
        mbeB           (152),
        mbeU           (153),
        tre            (154),

        hsuI           (155),
        hsr            (156),
        hss            (157),
        hsu1           (158),

        ls12           (159),
        ls6            (160),
        ls6V1EandM     (161),
        ls6V1Fxo       (162),
        ls6V1Fxs       (163),
        ls6V2EandM     (164),
        ls6V2Fxo       (165),
        ls6V2Fxs       (166),
        ls6VfEandM     (167),
        ls6VfFxo       (168),
        ls6VfFxs       (169),

        vc3EandM       (170),
        vc3Fxo         (171),
        vc3Fxs         (172),

        vcPbx          (173),
        vcPbxT1        (174),
        vcPbxE1        (175),

        vc6EandM       (176),
        vc6Fxo         (177),
        vc6Fxs         (178),
        
        vcq            (179),

        ls6n           (180),

--
-- Packet Cards of Maxcess and Hybrid
--

-- High speed cards

        mhs1V36        (181),
        mhs1V35        (182),
        mhs1G703       (183),
        mhs1DDS        (184),
        mhs3           (185),
        mhs1X21        (186),
        mhs1V24        (187),
        mhs4           (188),
        mhsE1Hs        (189),
        mhsT1Hs        (190),
        mhsHyE1Hs      (191), -- 2 HS ports + 1 Hybrid E1 port
        mhsHyT1Hs      (192), -- 2 HS ports + 1 Hybrid T1 port
        mlfHybE1Hs     (193), -- Fiber Optic Hybrid: 2 HS + 1 Hybrid E1 port
        mlfHybT1Hs     (194), -- Fiber Optic Hybrid: 2 HS + 1 Hybrid T1 port 

-- T1/E1 cards

        mhs2e1         (195),
        mhs2t1         (196),
        mhsHy2e1       (197), -- 2 Hybrid E1 ports
        mhsHy2t1       (198), -- 2 Hybrid T1 ports
        mlfHybE12      (199), -- Fiber Optic Hybrid: 2 E1 ports

-- Low speed cards

        mls6           (200),
        mls3           (201),


-- More  T1/E1 cards
        mlHybAtmE1     (202), -- Hybrid ATM E1
        mlHybAtmT1     (203), -- Hybrid ATM T1
        mlfHybT12      (204), -- Fiber Optic Hybrid: 2 T1 ports

--  Voice cards

        mvc8           (205), -- MVC-8 name in marketing: MVC-4N
        mvc8PbxE1      (206),
        mvc8PbxT1Dsu   (207),
        mvc8PbxT1Csu   (208),
        mvc8PbxE1Slave (209),

  
        mvc4           (210),
        mvc4PbxE1      (211),
        mvc4PbxT1Dsu   (212),
        mvc4PbxT1Csu   (213),
        mvc4PbxE1Slave (214),
        mvc4PbxT1Slave (215),

        mvc8PbxT1Slave (216), -- MVC-8 T1 Slave is here 
        mvc8ExtAnalog  (217), -- MVC-8 with 8 External ports
        mvcE1          (218), -- 8 External ports & 30 Internals
        mvcT1          (219), -- 8 External ports & 24 Internals

-- ISDN for Maxcess
        mhsS           (220),
        mhsU           (221),
        mhsPriE1       (222),
        mhsPriT1       (223),

-- Card of MP-2100/4
        hsEthSwitch    (224),

-- CCS for Maxcess & MPH
        mPriE1FramerCcs  (225),
        mPriT1FramerCcs  (226),
        mpriE1SlaveCcs   (227),
        mpriT1SlaveCcs   (228),
        mDualBri         (229),

-- Voice cards for MP
        vc12EandM        (230),
        vc12Fxo          (231),
        vc12Fxs          (232),
        vc6aEandM        (233),
        vc6aFxo          (234),
        vc6aFxs          (235),
        vc6AgFxo         (236),
        vc6AgFxs         (237),
        vc6a4LB          (238),

-- Video card for MP
        vid              (239),

-- ISDN cards for MP
        hsu12            (240),
        hsu6             (241),
        hss12            (242),
        hss6             (243),

-- MPH and MP-2100/4 cards
        hsDp3            (244),   
        hsDp6            (245),   

-- MP-2100/4 card
        hsf1             (246),

-- More Hybrid cards + IP cards for MPH
        mhsHyE1          (247), -- 1 Hybrid E1 port
        mhsHyT1          (248), -- 1 Hybrid T1 port         
        mhsIp            (249), -- 1 Eth  port + 1 HS port
        mlIpHs           (250), -- 1 Eth  port + 3 HS ports
        mlHybIpE1        (251), -- 1 Eth  port + 1 HS port + 1 E1
        mlHybIpT1        (252), -- 1 Eth  port + 1 HS port + 1 T1

-- VOIP cards for MPH & MX
        mvg1Lan          (253),
        mvg2Lan          (254),

-- MP-2100/4 card
        vc4Fxs           (255),
        vc4EandM         (256),
        vc4Fxo           (257),
        hsf2             (258),

-- More VOIP cards for MPH
        mvgSwitch4Lan    (260),

-- SHDSL cards of Megaplex
        msl4E1W2         (261),
        msl4E1W4         (262),
        msl8E1W2         (263),
        msl4E1W2Eth      (264),
        msl8E1W2Eth      (265),
        asmi54cE1AndEth  (266), -- & LRS-102 (E1 & ETH)
        asmi54cT1AndEth  (267), -- & LRS-102 (T1 & ETH)
        asmi54c          (268), -- & LRS-102 (ETH only)

-- HS cards of Megaplex
        hs6N             (271),
        hs12N            (272),
        hsNRZ            (273),

-- Vmux 2100 Enhanced Voice Cards
        evc2E1           (281),
        evc4E1           (282),
        evc2T1           (283),
        evc4T1           (284),

-- Vmux-2200  Voice cards 
        vc2E1Pri         (285),
        vc4E1Pri         (286),

-- MP Voice cards
        vc4OmniEandM     (291),
        vc4OmniWestern   (292),
       
-- MP-4100 and/or LRS-102 cards
        clx1             (301),
        clx1GbE          (302),
        clx1S155         (303),
        clx1S155GbE      (304),
        ml8T1Eth         (305),
        ml8E1Eth         (306),
        op106cEth        (307), -- no external T1
        op108cEth        (308), -- no external E1
        op106cEthT1      (309), -- with external T1 (used also by LRS-102)
        op108cEthE1      (310), -- with external E1 (used also by LRS-102)
        op108cEthE1Unbal (311), -- used only by LRS-102
        mpw1             (312),
        op34c            (313), -- no external E1
        op25c            (314), -- no external T1
        op34cE1          (315), -- with external E1 (used also by LRS-102)
        op25cT1          (316), -- with external T1 (used also by LRS-102)
        m16e1            (317), 
        m16t1            (318), 
        op108cE1Unbal    (319), -- used only by LRS-102
        op108cE1Bal      (320), -- used only by LRS-102.
       
-- VFS cards of Megaplex
        vfs24T1          (321),
        vfs30E1          (322),
        vfs48T1          (323), -- 2T1
        vfs60E1          (324), -- 2E1                

-- MiniCVS cards: This is a placeholder. The following cards exist only in the mdlSInstCardType.
--        mm4E1            (325),
--        mm4T1            (326),
--        mm8E1            (327),
--        mm8T1            (328),
--        mm12E1           (329),
--        mm12T1           (330),
--        mm16E1           (331),
--        mm16T1           (332),
      
-- More MP-4100 / LRS-102  SDHSL Cards
        asmi54cE1N       (340), -- E1 only New Hardware
        asmi54cN         (341), -- ETH only New Hardware
        asmi54cHsN       (342), -- V.35 only (HighSpeed) New Hardware
        asmi54cHsAndEthN (343), -- ETH & V.35 (HighSpeed) New Hardware

-- MP4100 R3.0 cards
        cl2n             (350), -- CL.2   
        cl2GbE           (351), -- CL.2-GbE
        cl2s622          (352), -- CL.2-622
        cl2s622GbE       (353), -- CL.2-622GbE
        cl2s622GbEa      (354), -- CL.2-622GbE/a with Advanced ETH features
        cl2GbEa          (355), -- CL.2-GbE a with Advanced ETH features
        cl2ds0           (356), -- CL.2 with DS0 cross connect capabilities only  

-- MP4104 cards (horizontal , low cost hub, lowprofile panels )
        cl2nl            (360), -- CL.2   
        cl2GbEl          (361), -- CL.2-GbE
        cl2s622l         (362), -- CL.2-622
        cl2s622GbEl      (363), -- CL.2-622GbE
        cl2s622GbEal     (364), -- CL.2-622GbE/a with Advanced ETH features
        cl2GbEal         (365), -- CL.2-GbE a with Advanced ETH features
        cl2ds0l          (366), -- CL.2 with DS0 cross connect capabilities only      
       
-- MP4100 R3.1 cards       
        mEth6            (370), -- M-ETH6 Card   
        mEth8            (371), -- M-ETH8 Card

-- TeleProtection Module
        mTp              (372), -- TeleProtection module

-- MP4100 R3.4 cards        
        mT3              (373), -- M-T3 DS3
       
        mEthPoe          (374), -- M-ETH8 with Power Over Ethernet support.       
       
-- MP4100 R4.5 cards
-- X Module based cards
        mp4mSh16         (381), -- MP-4M-SH-16
        mp4mVs12         (382), -- MP-4M-VS-12
        mp4mVs6s37       (383), -- MP-4M-VS-6/37
        mp4mVs6Bin       (384), -- MP-4M-VS-6/BIN
        mp4mVs6E1T1      (385), -- MP-4M-VS-6/E1T1
        mp4mE1T1         (386), -- MP-4M-E1T1
        mp4mT3           (387), -- MP-4M-T3
        mp4mVs6Fxs       (388), -- MP-4M-VS6-FXS 
        mp4mVs6Fxo       (389), -- MP-4M-VS6-FXO
        mp4mVs6Em        (390), -- MP-4M-VS6-EM
        mp4mFxsEm        (391), -- MP-4M-FXS-EM
       
-- MP4100 R4.7 cards       
        mp4mshE1         (392), -- MP-4M-SH-E1
        mp4mshE1Pw       (393), -- MP-4M-SH-E1-PW
        mp4mvs16E1Eop    (394), -- MP-4M-VS-16E1/EOP
        mp4mvs16T1Eop    (395), -- MP-4M-VS-16T1/EOP
        mp4mvs16E1Pw     (396), -- MP-4M-VS-16E1/PW
        mp4mvs16T1Pw     (397), -- MP-4M-VS-16T1/PW
        mp4mvs6S8E1Pw    (398), -- MP-4M-VS-6S/8E1/PW
        mp4mvs6S8T1Pw    (399), -- MP-4M-VS-6S/8T1/PW
    
-- Virtual Entity  ( x.86 Module )
        mp4mDnfv1        (401), -- MP-4M-DNFV-1  virtual entity (X.86 module)    

--MP4100 R4.9 cards 
        mp4mvsG703       (411), -- MP-4M-VS-G703
        mp4mVs6FxsPwAcr  (412), -- MP-4M-VS6-FXS-PW-ACR
        mp4mVs6FxoPwAcr  (413), -- MP-4M-VS6-FXO-PW-ACR
        mp4mVs6EmPwAcr   (414)  -- MP-4M-VS6-EM-PW-ACR      

        }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the type of card assigned to the
       specific slot in the common configuration.
       This object is identical in all the configurations (1..100).
       Only the TmpCnf(255) may have different value.
       The write operation is valid only to the TmpCnfg entry."
      ::= { mdlCPrgEntry 3}

mdlCNoOfExternPrt OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Number of external ports in the programmed card of the
       specific slot position"
      ::= { mdlCPrgEntry 4}

mdlCNoOfInternPrt OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Number of internal ports in the programmed card of the
       specific slot position."
      ::= { mdlCPrgEntry 5}

mdlCWorkMode OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable (1),
	   standAlone    (2),
	   integrated    (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Working mode of the card.
       The user may configure the card to work in a stand alone mode or integrated
       with the device.
       
	   Example for use in MHS-IP cards:

       - standAlone - in this mode, the router works so that data is received
         via the LAN (Eth) port and is transmitted via the WAN (HS) external port
         without going through the MPH device.

       - integrated - in this mode, the router works so that it is integrated in the MPH
         and routes DLCIs into the device."
      ::= { mdlCPrgEntry 6}

mdlCDhcpClientEnable OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable (1),
	   disable       (2),
	   enable        (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Enable/Disable the feature of DHCP Client for the selected card."
      ::= { mdlCPrgEntry 7} 

mdlCRdnExists OBJECT-TYPE
      SYNTAX  INTEGER
       {
	   no            (2),
	   yes           (3)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates whether any port of the programmed card is
       configured to be part of a Redundancy/APS pair.
       If at least one port of the programmed card is configured to be
       part of a Redundancy/APS pair, the value will be 'yes'. 
       Otherwise, it will be 'no'."
      ::= { mdlCPrgEntry 8}
      
mdlCInterfaces OBJECT-TYPE
  SYNTAX      OCTET STRING
  MAX-ACCESS  read-only
  STATUS  current
  DESCRIPTION
  "Octet string which indicates 'present' interfaces in card. 
  Each '0' bit  stands for non-present interface.
  Each '1' bit stands for present interface.

  For ASMi54C card of LRS-102 and MP-4100 notPresent interfaces may be:
     - SHDSL Line ID with no wire pairs assigned to it	(does not exist in ifTable)  
     - PCS without SHDSL Line binded to it, (exist in ifTable, with 
       ifOperStatus= notPresent)
     - External DS1 when its LIU is used by an Internal DS1 of the same card
     - Internal DS1 when single bearer is not TDM.

     In each octet, MS bit represents port 1 
     and LS bit represents port 8

         MSB           LSB
          1 0 0 0 1 0 0 0 -- Example: Port # 1 and 5 are present.
     Port 1 2 3 4 5 6 7 8 
  
     1st Octet (MSB octet) represents SDHSL Lines
     2nd Octet represents PCS 
     3rd Octet represents External DS1 
     4th Octet represents Internal DS1
     5th and 6th Octets are reserved for future Internal DS1.
  
  For OP-108/106 cards of LRS-102 and MP-4100 notPresent interfaces may be:
     - External DS1 when its 'associated' Int-DS1 port is connected to another card
     - Internal DS1 when its 'associated' Ext-DS1 port is connected to another card
    (Both may be 'present' when inter-connected).
     1st Octet represents External DS1 
     2nd Octet represents Internal DS1
	 Bit representation, same as for ASMi-54C card.
  "
  ::= { mdlCPrgEntry 9 }
      
       

--
-- Compressed information.
--
-- Specially for RadView management station
--
mdlCmprTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF MdlCmprEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "A table."
	::=  { cmprMdlGen 1 }

mdlCmprEntry OBJECT-TYPE
      SYNTAX MdlCmprEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX { mdlCmprTypIdx, mdlCmprCnfgIdx ,mdlCmprVersion,mdlCmprSltIdx }
      ::= {mdlCmprTable  1}

MdlCmprEntry ::=
      SEQUENCE {
  mdlCmprTypIdx     Integer32,
  mdlCmprCnfgIdx    Integer32,
  mdlCmprVersion    Integer32,
  mdlCmprSltIdx     INTEGER,
  mdlCmprObj        OCTET STRING
      }

mdlCmprTypIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Type of the Compressed being
       referred."
      ::= { mdlCmprEntry 1}

mdlCmprCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the configuration to which the
       Compressed information is  related."
      ::= { mdlCmprEntry 2}

mdlCmprVersion OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the version of the internal format
       of the Compressed data"
      ::= { mdlCmprEntry 3}

mdlCmprSltIdx  OBJECT-TYPE
      SYNTAX  INTEGER
       {
       psA   (1),
       psB   (2),
       clA   (3),
       clB   (4),
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique number of  the slot
       position where the card is inserted.
       In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16)
       are not valid."
      ::= { mdlCmprEntry 4}

mdlCmprObj OBJECT-TYPE
      SYNTAX  OCTET STRING
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute is the compressed information itself."
      ::= { mdlCmprEntry 5}

-- Compressed Alarm table at Card level
-- The only way of reading this table is by the command 'GET NEXT'

mdlAlarmsCmprTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF MdlAlarmsCmprEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "A table."
	::=  {cmprMdlGen 2}

mdlAlarmsCmprEntry OBJECT-TYPE
      SYNTAX MdlAlarmsCmprEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {mdlAlarmsCmprVersion,
             mdlAlarmsCmprAlarmSlot,mdlAlarmsCmprAlarmIdx}
      ::= {mdlAlarmsCmprTable  1}

MdlAlarmsCmprEntry ::=
      SEQUENCE {
     mdlAlarmsCmprVersion      Integer32,
     mdlAlarmsCmprAlarmSlot    Integer32,
     mdlAlarmsCmprAlarmIdx     Integer32,
     mdlAlarmsCmprObj          OCTET STRING
      }

mdlAlarmsCmprVersion OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the version of the internal format
       of the Compressed data"
      ::= { mdlAlarmsCmprEntry 1}

mdlAlarmsCmprAlarmSlot  OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the  desired slot position.
       In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io(16)
       are not valid."
      ::= { mdlAlarmsCmprEntry 2}

mdlAlarmsCmprAlarmIdx  OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A unique number to identify an entry in the alarm status table
       of the agent."
      ::= { mdlAlarmsCmprEntry 3}

mdlAlarmsCmprObj OBJECT-TYPE
      SYNTAX  OCTET STRING
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute is the compressed information itself."
      ::= { mdlAlarmsCmprEntry 4}


--
-- Wan port status general information
--
prtSInstTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtSInstEntry
      MAX-ACCESS not-accessible
      STATUS current
    DESCRIPTION  "A table."
    ::=  { statPrtGen 1 }

prtSInstEntry OBJECT-TYPE
      SYNTAX PrtSInstEntry
      MAX-ACCESS not-accessible
      STATUS current
    DESCRIPTION  "An entry in table."
    INDEX { prtSInstSltIdx, prtSInstPrtIdx }
      ::= { prtSInstTable 1}

PrtSInstEntry ::= SEQUENCE {
    prtSInstSltIdx       INTEGER,
    prtSInstPrtIdx       Integer32,
    prtSInstPrtType      INTEGER,
    prtSInstIfIndex      Integer32,
    prtSActiveStatus     INTEGER,
    prtSAlrStatus        INTEGER,
    prtSMaskedAlrStat    INTEGER,
    prtSClearAlrCmd      INTEGER,
    prtSTestMask         Integer32,
--        prtSTstStatus        INTEGER,
    prtSTstCmd           INTEGER,
    prtSTstDuration      Integer32,
    prtSBertClrCmd       INTEGER,
    prtSBertTstRslt      Integer32,
    prtSInterfaceType    DisplayString,
    prtSParamStatus      OCTET STRING,
    prtSTestMaskXp       OCTET STRING,
    prtSRdnStatus        INTEGER 
 }

prtSInstSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
       {
       clA   (3),
       clB   (4),
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
       notApplicable (255)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique number to identify the
       slot where the card is inserted.
       In the ?004 Unit the entries io6(10)..io(16) are not valid.
       For the Vmux2100 Main Board clA  (3) is used."
      ::= { prtSInstEntry 1}

prtSInstPrtIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique number to identify a port
       in a specific card.
       The valid ports depend on the installed card:
       the valid external ports (interfaces) are (1..mdlCNoOfExternPrt) if any,
       and the valid internal ports are (101..100+mdlCNoOfInternPrt) if any.
       Generally, for MP-2100/2200:  exPrt1 (1) .. exPrt16  (16),inPrt1(101) 
       .. inPrt48 (148)

       For the Vmux-2100 device:
       This index will have values of 1...4 for the physical ports & values
       of ifIndex for the bundles.

       For other products, see product's spec."
      ::= { prtSInstEntry 2}

prtSInstPrtType  OBJECT-TYPE
      SYNTAX  INTEGER
       {
  external      (2),
  internal      (3),
  highSpeedV35  (4),
  highSpeedV24  (5),
  highSpeedV36  (6),
  highSpeedX21  (7),
  highSpeedG703 (8),
  highSpeedDDS  (9),
  lowSpeed      (10),
  voice         (11),
  cl            (12),
  isdns         (13),
  isdnu         (14),
  ethernet      (15),
  voiceS0       (16),
  voiceU        (17),
  voiceQsigS    (18),
  voiceQsigU    (19)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
       "This attribute describes the type of the designated port.
       In MX 3000 only external & internal options are used.
       All the other options are only for MX 30/300 which need special handling.
       In order to support interface types in MX 3000, return an ascii string for
       prtSInterfaceType in this table or support the general RAD value of
       physicalConnector.

       External port - is a port with  a physical connector.
       Internal port - might be of two types:
         a) A composite port which collects a few external ports
            data into a common bandwidth (usually routed through
            DS1 link)
         b) A port which gets only part of the external ports
            (usually a few DS0's)
    The following types are used when all ports are external/
    internal and the connector/interface type is necessary
    (for example, stand-alone units):
       High Speed port types
       Low  Speed port types
       Voice port types, CL port types.
       
       ISDN Voice in MX 30/300 Phase 4: voiceS0   (16), voiceU     (17) should be used.
       ISDN Voice in MX 30/300 Phase 5: voiceQsigS(18), voiceQsigU (19) should be used."
      ::= { prtSInstEntry 3}

prtSInstIfIndex  OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the  unique  interface number
       assigned to the port. The specific interface of this
       attribute is the same as the interface identified by the
       value of ifindex  in MIB-II.If there is no interface for
       the specific prtIdx the value will be '7fffffff'h."
      ::= { prtSInstEntry 4}

prtSActiveStatus   OBJECT-TYPE
      SYNTAX  INTEGER
       {
         unknown           (1),
         notUsed           (2),
         offLine           (3),
         onLine            (4),
         offLineRedundancy (5),
         onLineRedundancy  (6)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute describes the activity status of the port.
       unknown(1) indicates that the information is not supported.
       notUsed(2) indicates that the ch is not connected according
                  to the active config.
       offLine(3) indicates that the ch is down (not working)
                  because of any problem.
       onLine(4)  indicates that the ch is up (working)
       offLineRedundancy(5) indicates that the ch is down, because
                            it is redundant port.
       onLineRedundancy(6)  indicates that the ch is up, and it is
                            the active link"
      ::= { prtSInstEntry 5}

prtSAlrStatus OBJECT-TYPE
      SYNTAX  INTEGER
       {
  off      (2),
  event    (3),
  minor    (4),
  major    (5),
  warning  (6),
  critical (7)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Indicates the alarm state in the port(ch) agent level.
      This attribute will be set to:
    critical(7) - when there is at least one active (state ON)
                  critical alarm,
                  otherwise it will be set to
       major(5) - when there is at least one active (state ON)
                  major alarm,
                  otherwise it will be set to
       minor(4) - if there is at least one active (state ON) minor
                  alarm,
                  otherwise it will be set to
       warning(6) - if there is at least one active (state ON)
                  warning alarm,
                  otherwise it will be set to
       event(3) - if there was at least one alarm event (including
                  state on,off events) since the last clear operation."
      ::= { prtSInstEntry 6}

prtSMaskedAlrStat OBJECT-TYPE
      SYNTAX  INTEGER
       {
  off      (2),
  event    (3),
  minor    (4),
  major    (5),
  warning  (6),
  critical (7)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Indicates the alarm state in the port(ch) agent level,
       including Masked alarms.
       This attribute will be set to:
    critical(7) - when there is at least one active (state ON)
                  critical alarm,
                  otherwise it will be set to
       major(5) - when there is at least one active (state ON)
                  major alarm,
                  otherwise it will be set to
       minor(4) - if there is at least one active (state ON) minor
                  alarm,
                  otherwise it will be set to
       warning(6) - if there is at least one active (state ON)
                  warning alarm,
                  otherwise it will be set to
       event(3) - if there was at least one alarm event (including
                  state on,off events) since the last clear operation."
 ::= {prtSInstEntry 7}

prtSClearAlrCmd  OBJECT-TYPE
      SYNTAX  INTEGER
       {
  off(2),
  on (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Setting this attribute to on(3) enforces a clear operation
       of the alarm status events in the given port. The clear
       operation will not be applied for masked/inverted alarms."
      ::= { prtSInstEntry 8}

prtSTestMask OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This is a mask which indicates which tests from the
       'prtSTstCmd' list are allowed for the requested port.
       If a specific test is allowed, its respective bit
       will be SET in the mask :

         TEST                  BIT
        -----------            ---
        local-loop              1
        remote-loop             2
        loc-and-rem-main-loops  3
        remote-analog-loop      4
        remote-digital-loop     5
        rem-loop-on-ext-unit    6
        bert                    7
        tone-injection          8
        dlci local-loop         9
        all dlci local-loop    10
        dlci remote-loop       11
        all dlci remote-loop   12
        bert-and-rem-loop-on-rem-unit 13
        rem-loop-on-rem-unit   14
        block                  15
        backward-tone-inject   16
        llb                    17
        rlb                    18

        ft1Enable              21
        lbbd                   22  --for 2B+D
        lb1                    23  --for B1
        lb2                    24  --for B2
        llb-on-rem-unit        25
        bert-on-rem-unit       26
        bert-on-rem-and-llb-on-rem-unit 27
        local-and-bert-on-rem-unit 28
        local-loop-on-rem-unit 29
        localBert              30  --towards IO ports
        test-per-TS            31

        e.g : If the return value is 3 -> 0000000000000011  ->
              Bits 1 & 2 are set -> the allowed tests are :
                                           local-loop
                                           remote-loop
        "
      ::= { prtSInstEntry 9}

-- prtSTstStatus OBJECT-TYPE
--      SYNTAX  INTEGER
--          {
--        off(2),
--        on (3)
--          }
--      MAX-ACCESS  read-only
--      STATUS  current
--      DESCRIPTION
--      "This attribute will be set to on(3) when there is at least
--       one test in progress in the port, otherwise the value
--       will be off(2)."
--      ::= { prtSInstEntry 10}
--


prtSTstCmd OBJECT-TYPE
      SYNTAX  INTEGER
       {
        none                 (1),
        localLoop            (2),
        remoteLoop           (3),
        locAndRemMainLoops   (4),
        remoteAnalogLoop     (5),
        remoteDigitalLoop    (6),
        remLoopOnExtUnit     (7),
        bert                 (8),
        toneInjection        (9),
        dlciLocalLoop        (10),
        allDlciLocalLoop     (11),
        dlciRemoteLoop       (12),
        allDlciRemoteLoop    (13),
        extInitLocalLoop     (14),
        bertAndRemLoopOnRemUnit (15),
        remLoopOnRemUnit     (16),
        block                (17),
        backwardToneInject   (18),
        llb                  (19),
        rlb                  (20),
        ft1Enable            (21),
        lbbd                 (22),  --for 2B+D
        lb1                  (23),  --for B1
        lb2                  (24),  --for B2
        llbOnRemUnit         (25),
        bertOnRemUnit        (26),
        bertOnRemAndLlbOnRemUnit (27),
        localAndBertOnRemUnit(28),
        localLoopOnRemUnit   (29),
        localBert            (30),
        testPerTS            (31),
        csuLoopAndBert       (32),
        dsuLoopAndBert       (33),
        remoteOcuLoopAndBert (34),
        remoteCsuLoopAndBert (35),
        remoteDsuLoopAndBert (36)

       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Setting this attribute to any of the above values will
       initiate a test on the specific port if the operation is
       legal. If the operation is not legal, the mux will ignore
       the operation.
       testPerTS(31) - when this test is selected, the selection of tests
                       for each TS is done via the prtExPh1MlTsTest object. 
       If a test time out is needed, the test will be set with a
       default timeout of 2 minutes until the user will set the
       parameter 'prtSTstDuration' to the required time out.
       If no time out is needed , the test will be set with infinite
       timeout until the user will set the parameter
       'prtSTstDuration' to the required time out."
      ::= { prtSInstEntry 10}

prtSTstDuration OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the maximum duration of executing
      a test on the specific port. This entry applies to all the
      test operations. The resolution will be a minute, and the
      maximum duration is limited to 30 minutes.

      For Vmux devices, the values are in seconds.

      A zero  value specifies no time limitation.
      When the test isn't active, the agent initiates this object to
      2 when the duration is needed and to 0 if its not required.
      The user should set this parameter after setting the
      'prtSTstCmd' parameter."
      ::= { prtSInstEntry 11}

prtSBertClrCmd  OBJECT-TYPE
      SYNTAX  INTEGER {
      off(2),
      on (3)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Setting this attribute initiates bert count clear operation.
       It is valid only when bert test is active on the specific
       port."
      ::= { prtSInstEntry 12}

prtSBertTstRslt   OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the number of Bit Error Rate
       indicated during the BERT operation.
       It is valid only when bert test is active on the specific
       port."
      ::= { prtSInstEntry 13}

prtSInterfaceType OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..255))
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique HW interface type of the
       selected port."
      ::= { prtSInstEntry 14}

prtSParamStatus OBJECT-TYPE
      SYNTAX  OCTET STRING
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates Status of parameters specific to the
       selected port.
       - For a port that has no special status or is supported
         by prtSExHsfStatTable - 1 Octet: 00hex

       - For VC-6, VC-6A, VC-6AG, VC-6A/4LB, VC-12, VC-12/6,  external ports - 1 Octet :
         Bit 7 (MSB)..Bit 2 = 0 (NA)
         Bit 1:       Tx Signaling '1'=On ; '0'=Off
         Bit 0 (LSB): Rx Signaling '1'=On ; '0'=Off

       - For VC-2/R2(FXS) external ports - 1 Octet :
         Bit  -   7 6 5 4 3 2 1 0
                  |_| |_________|
                  Call  Call State
             Direction

         Bit 7 (MSB) and Bit 6  : Call Direction
         00 - Incoming
         01 - Outgoing
         Bit 5..Bit 0: Call State
         000000 - Idle
         000001 - Seized
         000010 - Both-Way Conflict
         000011 - Seizure Ack
         000100 - Answered
         000101 - Clear Backward
         000110 - Clear Forward
         000111 - Blocked
         001000 - Fault
         001001 - Fault 3
         001010 - Fault 4
         001011 - Fault 5
         001100 - Fault 6
         001101 - Fault 7

       - For ML-20 external port - 3 Octets :
         - 1 MS Octet will represent the Real Rate used:
               Bit    - 7 6 5 4 3 2 1 0
                        |___| |_______|
                        spare    Rate

           Valid values: 0..31, meaning 0..31x64Kbps
           Invalid values: 32..255.
         - 2 LS Octets will represent the Status of 7 Control
           Signals:
           Signal - ---  CTS  DSR  DCD   RJ   TM   DTR  RTS
           Bit   - 7 6  5 4  3 2  1 0    7 6  5 4  3 2  1 0
           Octet  -          2                     3 (LS)
           '---' will always have the value 00
           Rest of the Signals (2 bits each) can have the following
           values:
           00=NA   ;  01=unused ; 10=Off  ; 11=On

       - For ML-H/E1, ML-H/1/E1, ML-H/S/E1 internal port - 1 Octet
         Bit    - 7 6 5 4 3 2 1 0
                  |___________|
                    spare       Mode of Operation

         Mode of Operation: '1'=Central  ; '0'=Remote

       - For ACM external port - 1 Octet
         Bit    - 7 6 5 4 3 2 1 0
                  |_________|
                    spare       Alarm State

         Alarm State: according to bits 1,0:
         00=NA   ;  01=unused ; 10=Off  ; 11=On

       - For HS-U/1 external port - 1 Octet
         Bit 7  6  5  4  3  2  1  0 LSB
             |________|  |__|  |__|
               spare     modem  sync  
               
         modem: 00 = other         sync:  00 = not sync
                01 = unknown              01 = sync
                10 = ASMi-31/2            10 = reserved
                11 = reserved             11 = reserved
         
       - For MTML-2/4  external ports, ML-8 externalports, ML-IP (MTML-IP) 
         internal ports and MTML-E2 internal ports - 1 Octet :
         Bit 7  6  5  4  3  2  1  0 LSB
                                  |
                                 BERT State
         BERT State (Bit 0):
         0 = OFF (BERT is not running on this port or any of its TSs/Bits)
         1 = ON  (BERT is running on this port OR on one of its TSs/Bits)
         
       - For ML-20N external ports - 4 Octets 
         - 1 MS Octet will represent the Actual Link Rate:
               Bit    - 7 6 5 4 3 2 1 0
                        |_| |_________|
                       spare    Rate

           Valid values: 0..34, meaning: 
           0..32 = (0..32)x64Kbps
           33 = Invalid Rate
           34 = not applicable (when Rate is not Auto)
           35 = 0 Kbps

           Invalid values: 36..255.

         - 2 middle Octets will represent the Status of 4 Control
           Signals: 
           - LS Octet - Bits 3-0: RTS/C (Command, for X.21 interface)
                        Bits 7-4: DCD/I (Indication for X.21 interface) 
           - MS Octet - Bits 3-0: DTR
                        Bits 7-4: DSR
           Each 4 Bits are divided as follows:
           - 2 MS bits: DCE
           - 2 LS bits: DTE
           For each 2 bits (DCE/DTE): 
           00=NA   ;  01=unused ; 10=Off  ; 11=On.

        
         - LS Octet: (as for MTML-2):
           Bit 7  6  5  4  3  2  1  0 LSB
                                    |
                                 BERT State
           BERT State (Bit 0):
           0 = OFF (BERT is not running on this port or any of its TSs/Bits)
           1 = ON  (BERT is running on this port OR on one of its TSs/Bits) 

           
       - For MP-2100/2200 MSL-4/E1, MSL-8/E1 External ports - 3 Octets
         - MS octet: far-end modem channel interface
         - Middle octet: Material (plastic/metal), far-end modem type,   
                         synchronization with far-end modem
         - LS octet: BERT state (at port/TS/Bit level)

         - MS octet: 0000 0000 = no interface
                     0000 0001 = db15 (X21)
                     0000 0010 = IR-IP
                     0000 0011 = IR-ETH-Q
                     0000 0100 = V35
                     0000 0101 = ETH-RJ45
                     0000 0110 = G703
                     0000 0111 = db25 (RS530)
                     0000 1000 = ETH-BNC
                     0000 1001 = E1(Balanced)
                     0000 1010 = E1(Unbalanced)
                     0000 1011 = IR-ETH-QN 
                     Rest of the combinations: reserved
   
          - Middle octet:
                     
         Bit 7  6  5  4  3  2  1  0 LSB
             |  |___________|  |__|
    Box material     modem     sync
          
               
    Box material      modem: 00000 = other      sync:  00 = not sync
    (for ASMi-52 SA)         00001 = unknown           01 = sync
    0=metal                  00010 = reserved          10 = reserved
    1=plastic                00011 = reserved          11 = reserved
                             00100 = reserved           
                             00101 = reserved
                             00110 = ASMi-52 SA/2W/Slave
                             00111 = ASMi-52 SA/2W/Master     
                             01000 = ASMi-52/CQ card of LRS-24
                             01001 = ASMi-52/CD card of LRS-24
                             01010 = D16GSDSL card of DXC-3000
                             01011 = LRS-52
                             01100 = FCD-IP
                             01101 = FCD-IPM  
                             01110 = D8SL card of DXC-30
                             01111 = ASMi-52A
                             10000 = MP card (SHDSL)
                             10001 = ASMi-52L 
                             Rest  = reserved 

          - LS Octet: (as for MTML-2):
            Bit 7  6  5  4  3  2  1  0 LSB
                                     |
                                 BERT State
            BERT State (Bit 0):
            0 = OFF (BERT is not running on this port or any of its TSs)
            1 = ON  (BERT is running on this port OR on one of its TSs)

       - For MP-4100 MSL card Links - 4 Octets
         - MS octet: far-end modem DTE2 interface (same as for MP-2100 MSL cards)
         - after MS octet: far-end modem DTE1 interface (same as for MP-2100 MSL cards)
         - before LS octet: Material (plastic/metal), far-end modem type,   
                         synchronization with far-end modem (same as for MP-2100 MSL cards)
         - LS octet: BERT state (at port/TS/Bit level)- same as for MP-2100 MSL cards

       - For MP-4100, LRS-102 OP-108/106 , OP-34/25 Links - 3 Octets
         - MS octet: Far-End PS type and state
         - Middle octet: synchronization with Far-End device
         - LS octet: BERT state (at port/TS level) - same as for MP-2100 MSL cards

         - MS octet:
           Bit 7  6  5  4    3  2  1  0 LSB
               |__|  |__|    |__|  |__|
               PS-A  PS-A    PS-B  PS-B  
            PS Type PS State PS Type PS State
            00=None                  00=None
            01=AC-DC                 01=OK
            10=DC                    10=Fail
            11=AC
            
          - Middle octet:
                     
           Bit 7  6  5  4  3  2  1  0 LSB
                                 |__|
                                 sync:          
                                     00 = not sync
                                     01 = sync
                                     10 = reserved
                                     11 = reserved
            Rest  = reserved             
            "
      ::= { prtSInstEntry 15}

prtSTestMaskXp OBJECT-TYPE
      SYNTAX  OCTET STRING
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This is an Expanded test mask of the prtSTestMask object.
       The prtSTestMask object reached its maximum, being an Integer with 32 bits.
       This object indicates which tests from the  'prtSTstCmdXP' list are 
       allowed for the selected port.
       If a specific test is allowed, its respective bit will be SET 
       in the mask :

         TEST                  BIT
        -----------            ---
        local-loop              1
        remote-loop             2
        loc-and-rem-main-loops  3
        remote-analog-loop      4
        remote-digital-loop     5
        rem-loop-on-ext-unit    6
        bert                    7
        tone-injection          8
        dlci local-loop         9
        all dlci local-loop    10
        dlci remote-loop       11
        all dlci remote-loop   12
        bert-and-rem-loop-on-rem-unit 13
        rem-loop-on-rem-unit   14
        block                  15
        backward-tone-inject   16
        llb                    17
        rlb                    18

        ft1Enable              21
        lbbd                   22  --for 2B+D
        lb1                    23  --for B1
        lb2                    24  --for B2
        llb-on-rem-unit        25
        bert-on-rem-unit       26
        bert-on-rem-and-llb-on-rem-unit 27
        local-and-bert-on-rem-unit 28
        local-loop-on-rem-unit 29
        localBert              30  --towards IO ports
        test-per-TS            31
        csuLoopAndBert         32
        dsuLoopAndBert         33
        remoteOcuLoopAndBert   34
        remoteCsuLoopAndBert   35
        remoteDsuLoopAndBert   36

        e.g : If the return value is  00000003 hex  ->
              Bits 1 & 2 are set -> the allowed tests are :
                                           local-loop
                                           remote-loop  "
      ::= { prtSInstEntry 16}

prtSRdnStatus  OBJECT-TYPE
      SYNTAX  INTEGER {
      noRdn  (1),
      offline(2),
      online (3)
      }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Redundancy Status of this port.
       noRdn - this port is not part of a Redundancy pair/group.
       offline - this port is offline from Redundancy point of view.
       online  - this port is online from Redundancy point of view."
      ::= { prtSInstEntry 17}




prtSAlrTable OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtSAlrEntry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
      "The list of port agent alarms."
      ::= { statPrtGen 2 }

prtSAlrEntry OBJECT-TYPE
      SYNTAX PrtSAlrEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX { prtSAlrSltIdx, prtSAlrPrtIdx, prtSAlrIdx}
      ::= { prtSAlrTable 1}

PrtSAlrEntry ::=
      SEQUENCE {
  prtSAlrSltIdx            INTEGER,
  prtSAlrPrtIdx            Integer32,
  prtSAlrIdx               Integer32,
  prtSAlrCodeDescription   DisplayString,
  prtSAlrCode              Integer32,
  prtSAlrSeverity          INTEGER,
  prtSAlrState             INTEGER,
  prtSAlrCounter           Integer32,
  prtSAlrMask              INTEGER,
  prtSAlrInvert            INTEGER,
  prtSAlrCardType          INTEGER
      }

prtSAlrIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A unique number to identify an entry in the alarm status table.
       Users should use the get next function to read this table because
       the indexes are not consecutive"
      ::= { prtSAlrEntry 1}

prtSAlrSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
       {
       psA   (1),
       psB   (2),
       clA   (3),
       clB   (4),
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
    notApplicable (255)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique identifier of  the slot
       where the card is inserted.
       In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io12(16)
       are not valid.
       For the Vmux2100 Main Board clA  (3) is used."
    ::= { prtSAlrEntry 2}

prtSAlrPrtIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique identifier of  the port
       the alarm applies to.
       All the values are valid. No alarms exist for a port
       which does not exist.
       Valid valuesfor MP-2100/2200: exPrt1    (1) .. exPrt16  (16) ,
                     inPrt1  (101) .. inPrt48 (148),
                     IP Bundles.
       For other products, see product's spec."
    ::= { prtSAlrEntry 3}

prtSAlrCodeDescription OBJECT-TYPE
      SYNTAX  DisplayString (SIZE (0..255))
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute is a full text description of the alarm.
       The alarm description includes the following information:
       alarm code, alarm text, alarm severity, Masked  or Inverted
       flag and counter."
       ::= { prtSAlrEntry 4}

prtSAlrCode OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A code identifying the alarm of an entry in the alarm status
       table at port level."
      ::= { prtSAlrEntry 5 }

prtSAlrSeverity OBJECT-TYPE
      SYNTAX  INTEGER
       {
  event    (3),
  minor    (4),
  major    (5),
     warning  (6),
  critical (7)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The severity of the alarm."
      ::= { prtSAlrEntry 6 }

prtSAlrState  OBJECT-TYPE
      SYNTAX  INTEGER
       {
  off(2),
  on (3)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "State of the alarm."
      ::= { prtSAlrEntry 7 }

prtSAlrCounter OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A counter - how many times the alarm occured since last
       clear operation.
       ON and OFF Alarm will be counted separately."
      ::= { prtSAlrEntry 8 }

prtSAlrMask  OBJECT-TYPE
      SYNTAX  INTEGER
       {
       off(2),
       on (3)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Alarm mask : on/off."
      ::= { prtSAlrEntry 9 }

prtSAlrInvert  OBJECT-TYPE
      SYNTAX  INTEGER
       {
       off(2),
       on (3)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Alarm invert : on/off."
      ::= { prtSAlrEntry 10 }

prtSAlrCardType OBJECT-TYPE
   SYNTAX  INTEGER
   {
  --
  -- General types
  --		 
         unknown        (1),
         empty          (2),
  --
  -- Power Supply Modules
  --
		ps             (17), 


  --
  -- Cl Modules
  --
		cl1				(20),
		cl1Clk          (26), --CL1 with Station Clock (for LRS102)


 
  -- VF cards of Megaplex
        vf24T1          (62),
		vf30E1          (63),
		vf48T1          (64),
		vf60E1          (65),
  --
  -- TDM Cards
  --
      vc8EandM          (74),
      vc8Fxo            (75),
      vc8Fxs            (76),
      vc16EandM         (77),
      vc16Fxo           (78),
      vc16Fxs           (79),

	   ml8T1           (134),
	   ml8E1           (135),     

       hsr             (156),

       ls12            (159),

       ls6n            (180),

       hsEthSwitch     (224),

       hsu12           (240),
	   hsu6            (241),

       vc4Fxs          (255),
       vc4EandM        (256),
	   vc4Fxo          (257),

       msl4E1W2        (261),

	   msl8E1W2        (263),
       msl4E1W2Eth     (264),
	   msl8E1W2Eth     (265),
       asmi54cE1AndEth (266), -- & LRS-102 (E1 & ETH)
       asmi54cT1AndEth (267), -- & LRS-102 (T1 & ETH)
	   asmi54c         (268), -- & LRS-102 (ETH only)

 	   hs6N            (271),
	   hs12N           (272),
       
   --  MP-4100 (and LRS-102) cards
       clx1            (301),
       clx1GbE         (302),
       clx1S155        (303),
       clx1S155GbE     (304),
       ml8T1Eth        (305),
       ml8E1Eth        (306),
	   op106cEth       (307), --no external T1
	   op108cEth       (308), --no external E1
	   op106cEthT1     (309), --with external T1 (used also by LRS-102)
	   op108cEthE1     (310), --with external E1 (used also by LRS-102)
	   op108cEthE1Unbal(311), --used only by LRS-102
	   mpw1            (312),
       
  -- VFS cards of Megaplex
        vfs24T1        (321),
		vfs30E1        (322),
		vfs48T1        (323),  --2T1
		vfs60E1        (324)   --2E1                
     }
   MAX-ACCESS  read-only
   STATUS  current
   DESCRIPTION
   "This attribute indicates the type of card installed
    in the specific slot position. The enumeration is according
    to mdlSInstCardType."
    ::= { prtSAlrEntry 11 }

--
-- Statistics of Ports
--

--statisPrtGen   OBJECT IDENTIFIER ::= {statPrtGen 3}

--prtFrStatis    OBJECT IDENTIFIER ::= {statisPrtGen 1}
--prtCrStatis    OBJECT IDENTIFIER ::= {statisPrtGen 2}
--prtDlciStatis  OBJECT IDENTIFIER ::= {statisPrtGen 3}
--prtT1Statis    OBJECT IDENTIFIER ::= {statisPrtGen 4}


--prtFrStatis - Port Statistics for (FR) Frame Relay protocol

prtFrStatisTable  OBJECT-TYPE
     SYNTAX SEQUENCE OF PrtFrStatisEntry
     MAX-ACCESS not-accessible
     STATUS  current
     DESCRIPTION
      "This table is applicable only for an active port running an
       FR protocol ."
  ::= { prtFrStatis 1}

prtFrStatisEntry OBJECT-TYPE
      SYNTAX PrtFrStatisEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtFrStatisSltIdx, prtFrStatisPrtIdx, prtFrStatisInvIdx}
      ::= { prtFrStatisTable 1}

PrtFrStatisEntry ::=
      SEQUENCE {
      prtFrStatisSltIdx    INTEGER,
      prtFrStatisPrtIdx    INTEGER,
   prtFrStatisInvIdx    INTEGER,
      prtFrTimeElapsed     Integer32,
      prtFrRxTotalFrames   Counter32,
      prtFrTxTotalFrames   Counter32,
      prtFrRxTotalBytes    Counter32,
      prtFrTxTotalBytes    Counter32,
      prtFrRxMngFrames     Counter32,
      prtFrTxMngFrames     Counter32,
      prtFrRxDeFrames      Counter32,
      prtFrTxDeFrames      Counter32,
      prtFrRxDcrdCongDeFr  Counter32,
      prtFrTxDcrdCongDeFr  Counter32,
      prtFrRxDcrdCongAllFr Counter32,
      prtFrTxDcrdCongAllFr Counter32,
      prtFrRxFecn     Counter32,
      prtFrTxFecn     Counter32,
      prtFrRxBecn     Counter32,
      prtFrTxBecn     Counter32,
      prtFrRxBeViol     Counter32,
      prtFrTxBeViol        Counter32,
      prtFrRxBcViol     Counter32,
      prtFrTxBcViol     Counter32
      }

prtFrStatisSltIdx    OBJECT-TYPE
      SYNTAX  INTEGER
       {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
       notApplicable (255)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the module is inserted.
       In the ?004 Unit the entries io6(10)..io12(16) are not valid.
       For stand-alone units this index will be notApplicable (255)."
      ::= { prtFrStatisEntry 1}

prtFrStatisPrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
      {
          exPrt1  (1) ,
          exPrt2  (2) ,
          exPrt3  (3) ,
          exPrt4  (4) ,
          exPrt5  (5) ,
          exPrt6  (6)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  port number."
      ::= { prtFrStatisEntry 2}

prtFrStatisInvIdx OBJECT-TYPE
      SYNTAX  INTEGER
       {
          currentInv (1),
    last       (2)
    }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
   "The Interval of 15 min. for which the following statistics
    counters are applicable."
      ::= { prtFrStatisEntry 3}

prtFrTimeElapsed OBJECT-TYPE
      SYNTAX  Integer32 (0..899)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The number of seconds that have elapsed  since the
       beginning of the current error-measurement interval.
       This object is applicable mainly for the current interval.
       For other interval:
       - if data is available: value will be 899.
       - if data is not available: value will be 0."
      ::= { prtFrStatisEntry 4 }

prtFrRxTotalFrames OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "The total number of frames received by this port during the
       selected interval."
      ::= { prtFrStatisEntry 5 }

prtFrTxTotalFrames OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "The total number of frames sent by this port during the
       selected interval."
      ::= { prtFrStatisEntry 6 }

prtFrRxTotalBytes OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "The total number of bytes received by this port during the
       selected interval."
      ::= { prtFrStatisEntry 7 }

prtFrTxTotalBytes OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "The total number of bytes sent by this port during the
       selected interval."
      ::= { prtFrStatisEntry 8 }

prtFrRxMngFrames OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "The management number of frames received by this port
       during the selected interval."
      ::= { prtFrStatisEntry 9 }

prtFrTxMngFrames OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "The management number of frames sent by this port during the
       selected interval."
      ::= { prtFrStatisEntry 10 }

prtFrRxDeFrames OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "The number of De frames received by this port during the
       selected interval."
      ::= { prtFrStatisEntry 11 }

prtFrTxDeFrames OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "The number of De frames sent by this port during the
       selected interval."
      ::= { prtFrStatisEntry 12 }

prtFrRxDcrdCongDeFr OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "The number of De frames discarded due to congestion,
       received by this port during the selected interval."
      ::= { prtFrStatisEntry 13 }

prtFrTxDcrdCongDeFr OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "The number of De frames discarded due to congestion,
       sent by this port during the selected interval."
      ::= { prtFrStatisEntry 14 }

prtFrRxDcrdCongAllFr OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "All the frames discarded due to congestion,
       received by this port during the selected interval."
      ::= { prtFrStatisEntry 15 }

prtFrTxDcrdCongAllFr OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "All the frames discarded due to congestion,
       sent by this port during the selected interval."
      ::= { prtFrStatisEntry 16 }

prtFrRxFecn OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "Number of frames received by this port during the
       selected interval, indicating forward congestion."
      ::= { prtFrStatisEntry 17 }

prtFrTxFecn OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "Number of frames sent by this port during the
       selected interval, indicating forward congestion."
      ::= { prtFrStatisEntry 18 }

prtFrRxBecn OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "Number of frames received by this port during the
       selected interval, indicating backward congestion."
      ::= { prtFrStatisEntry 19 }

prtFrTxBecn OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "Number of frames sent by this port during the
       selected interval, indicating backward congestion."
      ::= { prtFrStatisEntry 20 }

prtFrRxBeViol OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "Number of data frames received by this port during the
       selected interval, exceeding the Burst Excess value."
      ::= { prtFrStatisEntry 21 }

prtFrTxBeViol OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "Number of data frames sent by this port during the
       selected interval, exceeding the Burst Excess value."
      ::= { prtFrStatisEntry 22 }

prtFrRxBcViol OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "Number of data frames received by this port during the
       selected interval, exceeding the Burst Committed value."
      ::= { prtFrStatisEntry 23 }

prtFrTxBcViol OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "Number of data frames sent by this port during the
       selected interval, exceeding the Burst Committed value."
      ::= { prtFrStatisEntry 24 }


--prtCrStatis - Port Statistics for (CR) Cell Relay protocol

prtCrStatisTable  OBJECT-TYPE
     SYNTAX SEQUENCE OF PrtCrStatisEntry
     MAX-ACCESS not-accessible
     STATUS  current
     DESCRIPTION
      "This table is applicable only for an active port running a
       CR protocol ."
  ::= { prtCrStatis 1}

prtCrStatisEntry OBJECT-TYPE
      SYNTAX PrtCrStatisEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtCrStatisSltIdx, prtCrStatisPrtIdx, prtCrStatisInvIdx}
      ::= { prtCrStatisTable 1}

PrtCrStatisEntry ::=
      SEQUENCE {
      prtCrStatisSltIdx    INTEGER,
      prtCrStatisPrtIdx    INTEGER,
      prtCrStatisInvIdx    INTEGER,
      prtCrTimeElapsed     Integer32,
      prtCrRxTotalCells    Counter32,
      prtCrTxTotalCells    Counter32,
      prtCrRxDataCells     Counter32,
      prtCrTxDataCells     Counter32
      }

prtCrStatisSltIdx    OBJECT-TYPE
      SYNTAX  INTEGER
       {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
       notApplicable (255)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the module is inserted.
       In the ?004 Unit the entries io6(10)..io12(16) are not valid.
       For stand-alone units this index will be notApplicable (255)."
      ::= { prtCrStatisEntry 1}

prtCrStatisPrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
      {
          exPrt1  (1) ,
          exPrt2  (2) ,
          exPrt3  (3) ,
          exPrt4  (4) ,
          exPrt5  (5) ,
          exPrt6  (6)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  port number."
      ::= { prtCrStatisEntry 2}

prtCrStatisInvIdx OBJECT-TYPE
      SYNTAX  INTEGER
       {
          currentInv (1),
    last       (2)
    }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
   "The Interval of 15 min. for which the following statistics
    counters are applicable."
      ::= { prtCrStatisEntry 3}

prtCrTimeElapsed OBJECT-TYPE
      SYNTAX  Integer32 (0..899)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The number of seconds that have elapsed  since the
       beginning of the current error-measurement interval.
       This object is applicable mainly for the current interval.
       For other interval:
       - if data is available: value will be 899.
       - if data is not available: value will be 0."
      ::= { prtCrStatisEntry 4 }

prtCrRxTotalCells OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "The total number of cells received by this port during the
       selected interval."
      ::= { prtCrStatisEntry 5 }

prtCrTxTotalCells OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "The total number of cells sent by this port during the
       selected interval."
      ::= { prtCrStatisEntry 6 }

prtCrRxDataCells OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "The number of Data Cells received by this port during the
       selected interval."
      ::= { prtCrStatisEntry 7 }

prtCrTxDataCells OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "The number of Data Cells sent by this port during the
       selected interval."
      ::= { prtCrStatisEntry 8 }


--prtDlciStatis - Port DLCI Statistics for FR, FR+ and CR protocol

prtDlciStatisTable  OBJECT-TYPE
     SYNTAX SEQUENCE OF PrtDlciStatisEntry
     MAX-ACCESS not-accessible
     STATUS  current
     DESCRIPTION
      "This table is applicable only for an active port running an
       FR, FR+ or CR protocol, with valid DLCIs ."
  ::= { prtDlciStatis 1}

prtDlciStatisEntry OBJECT-TYPE
      SYNTAX PrtDlciStatisEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtDlciSltIdx, prtDlciPrtIdx, prtDlciIdx}
      ::= { prtDlciStatisTable 1}

PrtDlciStatisEntry ::=
      SEQUENCE {
      prtDlciSltIdx          INTEGER,
      prtDlciPrtIdx          INTEGER,
      prtDlciIdx             Integer32,
      prtDlciRxDeFrames      Counter32,
      prtDlciTxDeFrames      Counter32,
      prtDlciRxDcrdCongDeFr  Counter32,
      prtDlciTxDcrdCongDeFr  Counter32,
      prtDlciRxDcrdCongAllFr Counter32,
      prtDlciTxDcrdCongAllFr Counter32,
      prtDlciTxFecn       Counter32,
      prtDlciTxBecn       Counter32,
      prtDlciRxBeViol      Counter32,
      prtDlciTxBeViol        Counter32,
      prtDlciRxBcViol      Counter32,
      prtDlciTxBcViol       Counter32
      }

prtDlciSltIdx    OBJECT-TYPE
      SYNTAX  INTEGER
       {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
       notApplicable (255)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the module is inserted.
       In the ?004 Unit the entries io6(10)..io12(16) are not valid.
       For stand-alone units this index will be notApplicable (255)."
      ::= { prtDlciStatisEntry 1}

prtDlciPrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
      {
          exPrt1  (1) ,
          exPrt2  (2) ,
          exPrt3  (3) ,
          exPrt4  (4) ,
          exPrt5  (5) ,
          exPrt6  (6)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  port number."
      ::= { prtDlciStatisEntry 2}

prtDlciIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..991)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique DLCI index for each valid
       DLCI (16..991). "
      ::= { prtDlciStatisEntry 3}

prtDlciRxDeFrames OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "The number of De frames received by this DLCI."
      ::= { prtDlciStatisEntry 4 }

prtDlciTxDeFrames OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "The number of De frames sent by this DLCI."
      ::= { prtDlciStatisEntry 5 }

prtDlciRxDcrdCongDeFr OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "The number of De frames discarded due to congestion,
       received by this DLCI."
      ::= { prtDlciStatisEntry 6 }

prtDlciTxDcrdCongDeFr OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "The number of De frames discarded due to congestion,
       sent by this DLCI."
      ::= { prtDlciStatisEntry 7 }

prtDlciRxDcrdCongAllFr OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "All the frames discarded due to congestion,
       received by this DLCI."
      ::= { prtDlciStatisEntry 8 }

prtDlciTxDcrdCongAllFr OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "All the frames discarded due to congestion,
       sent by this DLCI."
      ::= { prtDlciStatisEntry 9 }

prtDlciTxFecn OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "Number of frames sent by this DLCI, indicating forward
       congestion."
      ::= { prtDlciStatisEntry 10 }

prtDlciTxBecn OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "Number of frames sent by this DLCI, indicating backward
       congestion."
      ::= { prtDlciStatisEntry 11 }

prtDlciRxBeViol OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "Number of data frames received by this DLCI, exceeding the
       Burst Excess value."
      ::= { prtDlciStatisEntry 12 }

prtDlciTxBeViol OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "Number of data frames sent by this DLCI, exceeding the Burst
       Excess value."
      ::= { prtDlciStatisEntry 13 }

prtDlciRxBcViol OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "Number of data frames received by this DLCI, exceeding the
       Burst Committed value."
      ::= { prtDlciStatisEntry 14 }

prtDlciTxBcViol OBJECT-TYPE
      SYNTAX   Counter32
      MAX-ACCESS   read-only
      STATUS   current
      DESCRIPTION
      "Number of data frames sent by this DLCI, exceeding the Burst
       Committed value."
      ::= { prtDlciStatisEntry 15 }


--prtT1 Last FDL Message Table - Statistics

prtT1FdlMsgTable  OBJECT-TYPE
     SYNTAX SEQUENCE OF PrtT1FdlMsgEntry
     MAX-ACCESS not-accessible
     STATUS  current
     DESCRIPTION
      "This table is applicable for a T1 interface with 'esf'
       LineType ."
  ::= { prtT1Statis 1}

prtT1FdlMsgEntry OBJECT-TYPE
      SYNTAX PrtT1FdlMsgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtT1FdlMsgSltIdx, prtT1FdlMsgPrtIdx, prtT1FdlMsgFdlTxRx}
      ::= { prtT1FdlMsgTable 1}

PrtT1FdlMsgEntry ::=
      SEQUENCE {
      prtT1FdlMsgSltIdx    INTEGER,
      prtT1FdlMsgPrtIdx    INTEGER,
      prtT1FdlMsgFdlTxRx   INTEGER,
      prtT1FdlMsg          OCTET STRING
      }

prtT1FdlMsgSltIdx    OBJECT-TYPE
      SYNTAX  INTEGER
       {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the module is inserted.
       In the ?004 Unit the entries io6(10)..io12(16) are not valid."
      ::= { prtT1FdlMsgEntry 1}

prtT1FdlMsgPrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
       {
       exPrt1    (1)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  port number.
       MTML-1/T1 modules have just one external interface."
      ::= { prtT1FdlMsgEntry 2}

prtT1FdlMsgFdlTxRx OBJECT-TYPE
      SYNTAX  INTEGER
       {
          tx    (1),
          rx    (2)
    }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
   "The Fdl tx/rx reference of the Fdl message."
      ::= { prtT1FdlMsgEntry 3}


prtT1FdlMsg  OBJECT-TYPE
   SYNTAX  OCTET STRING
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "FDL message."
      ::= { prtT1FdlMsgEntry 4}

--
-- Extension of the Time Slot Config Table of ML ports
--
-- Time Slot is split to 8 Bits


prtExTsSplitTable OBJECT-TYPE
     SYNTAX SEQUENCE OF PrtExTsSplitEntry
     MAX-ACCESS not-accessible
     STATUS  current
     DESCRIPTION
      "The write operation into the Table Objects is valid only
       to the TmpCnfg entry, except prtExTsBitTest that will be
       written directly to the Active Configuration."
     ::= {cnfgPrtGen 1}

prtExTsSplitEntry OBJECT-TYPE
      SYNTAX PrtExTsSplitEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtExTsCnfgIdx, prtExTsSltIdx, prtExTsPrtIdx,
             prtExTsIdx, prtExTsBit}
      ::= { prtExTsSplitTable 1}

PrtExTsSplitEntry ::=
      SEQUENCE {
      prtExTsCnfgIdx        Integer32,
      prtExTsSltIdx         INTEGER,
      prtExTsPrtIdx         Integer32,
      prtExTsIdx            Integer32,
      prtExTsBit            Integer32,
      prtExTsIConSlot       INTEGER,
      prtExTsIConPrt        Integer32,
	  prtExTsBitTest        INTEGER,
	  prtExTsTxSignaling    OCTET STRING,
	  prtExTsRxSignaling    OCTET STRING,
	  prtExTsTxIoSignaling  OCTET STRING,
	  prtExTsRxIoSignaling  OCTET STRING
      }

prtExTsCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32  (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg. "
      ::= { prtExTsSplitEntry 1}

prtExTsSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
     {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
       notApplicable (255)
        }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted.
       In the ?004 Unit the entries io6(10)..io12(16) are not valid.
       notApplicable - for stand-alone units."
      ::= { prtExTsSplitEntry 2}

prtExTsPrtIdx OBJECT-TYPE
      SYNTAX  Integer32
--  For MP:
--    {
--      exPrt1    (1),
--     inPrt1  (101)
--     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  port number.
       Most ML cards have only one external interface.
       inPrt1 - for MTML-H/E1 cards.
       For other products' index see their specification."
      ::= { prtExTsSplitEntry 3}

prtExTsIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique time slot  position.
       The valid time slots are:
       1..24 for T1 Card and
       1..31 for E1 interface.
       In G732S-E1 lines, time slot 16 is not valid for data,
       it is dedicated to multiframe synchronization bits
       and voice signaling."
      ::= { prtExTsSplitEntry 4}

prtExTsBit OBJECT-TYPE
      SYNTAX  Integer32 
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique Bit within the time slot.
       The valid Bits are: 1..8.
       255=NA."
      ::= { prtExTsSplitEntry 5}

prtExTsIConSlot OBJECT-TYPE
      SYNTAX  INTEGER
       {
       noConnect (2),
          io1       (5),
          io2       (6),
          io3       (7),
          io4       (8),
          io5       (9),
          io6      (10),
          io7      (11),
          io8      (12),
          io9      (13),
          io10     (14),
          io11     (15),
          io12     (16),
    notApplicable (255)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the specified time slot is
       connected/routed internally in the Agent and to which card
       it is connected.
       In the ?004 Unit the entries io6(10)..io12(16) are not valid.
       notApplicable - for stand-alone units."
      ::= {prtExTsSplitEntry 6}

prtExTsIConPrt OBJECT-TYPE
      SYNTAX  Integer32
--    For MP:
--       {
--       exPrt1    (1) ,
--       exPrt2    (2) ,
--       exPrt3    (3) ,
--       exPrt4    (4) ,
--       exPrt5    (5) ,
--       exPrt6    (6) ,
--       exPrt7    (7) ,
--       exPrt8    (8) ,
--       exPrt9    (9) ,
--       exPrt10  (10) ,
--       exPrt11  (11) ,
--       exPrt12  (12) ,
--
--        noConnect (100),
--
--       inPrt1  (101) ,
--       inPrt2  (102) ,
--       inPrt3  (103) ,
--       inPrt4  (104) ,
--       inPrt5  (105) ,
--       inPrt6  (106) ,
--       inPrt7  (107) ,
--       inPrt8  (108) ,
--       inPrt9  (109) ,
--       inPrt10 (110) ,
--    inPrt11 (111) ,
--    inPrt12 (112)
--       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the internally (In Mux)
       connected/routed port.
       For other products' index see their specification."
      ::= {prtExTsSplitEntry 7}

prtExTsBitTest OBJECT-TYPE
      SYNTAX  INTEGER
     {
       none                    (1),
       remoteBert              (8),
       localBert               (30),
       notApplicable           (255)
        }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a test to be activated on the selected Bit.
	   It is applicable only when prtExPh1MlTsTest=split(254).
	   none - no test is applied for the selected Bit.
       notApplicable - when prtExPh1MlTsTest is NOT split(254)."
      ::= { prtExTsSplitEntry 8}

prtExTsTxSignaling OBJECT-TYPE
        SYNTAX OCTET STRING
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
        "Link - Tx Signaling per TS, for TSs having TS Type=Voice
         (agnTsType=voice(2)). 
         It monitors what is sent to Link for the selected TS, 
         for A,B,C,D Signaling Bits.
         Bit 1= LSB
         Bit 8= MSB 
        Bit  1-2 = A Signaling Bit:  00='0'  ; 01='1' ; 10=not used ; 11=NA
        Bit  3-4 = B Signaling Bit:  00='0'  ; 01='1' ; 10=not used ; 11=NA
        Bit  5-6 = C Signaling Bit:  00='0'  ; 01='1' ; 10=not used ; 11=NA        
        Bit  7-8 = D Signaling Bit:  00='0'  ; 01='1' ; 10=not used ; 11=NA"
        ::= { prtExTsSplitEntry 9}

prtExTsRxSignaling OBJECT-TYPE
        SYNTAX OCTET STRING
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
        "Link - Rx Signaling per TS, for TSs having TS Type=Voice
         (agnTsType=voice(2)). 
         It monitors what is received from Link for the selected TS, 
         for A,B,C,D Signaling Bits.
         Bit 1= LSB
         Bit 8= MSB 
        Bit  1-2 = A Signaling Bit:  00='0'  ; 01='1' ; 10=not used ; 11=NA
        Bit  3-4 = B Signaling Bit:  00='0'  ; 01='1' ; 10=not used ; 11=NA
        Bit  5-6 = C Signaling Bit:  00='0'  ; 01='1' ; 10=not used ; 11=NA        
        Bit  7-8 = D Signaling Bit:  00='0'  ; 01='1' ; 10=not used ; 11=NA"
        ::= { prtExTsSplitEntry 10}

prtExTsTxIoSignaling OBJECT-TYPE
        SYNTAX OCTET STRING
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
        "IO - Tx Signaling per TS, for TSs having TS Type=Voice
         (agnTsType=voice(2)). 
         It monitors what is sent to IO port for the selected TS, 
         for A,B,C,D Signaling Bits.
         Bit 1= LSB
         Bit 8= MSB 
        Bit  1-2 = A Signaling Bit:  00='0'  ; 01='1' ; 10=not used ; 11=NA
        Bit  3-4 = B Signaling Bit:  00='0'  ; 01='1' ; 10=not used ; 11=NA
        Bit  5-6 = C Signaling Bit:  00='0'  ; 01='1' ; 10=not used ; 11=NA        
        Bit  7-8 = D Signaling Bit:  00='0'  ; 01='1' ; 10=not used ; 11=NA"
        ::= { prtExTsSplitEntry 11}

prtExTsRxIoSignaling OBJECT-TYPE
        SYNTAX OCTET STRING
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
        "IO - Rx Signaling per TS, for TSs having TS Type=Voice
         (agnTsType=voice(2)). 
         It monitors what is received from IO port for the selected TS, 
         for A,B,C,D Signaling Bits.
         Bit 1= LSB
         Bit 8= MSB 
        Bit  1-2 = A Signaling Bit:  00='0'  ; 01='1' ; 10=not used ; 11=NA
        Bit  3-4 = B Signaling Bit:  00='0'  ; 01='1' ; 10=not used ; 11=NA
        Bit  5-6 = C Signaling Bit:  00='0'  ; 01='1' ; 10=not used ; 11=NA        
        Bit  7-8 = D Signaling Bit:  00='0'  ; 01='1' ; 10=not used ; 11=NA"
        ::= { prtExTsSplitEntry 12}


prtCnfgAgenda OBJECT IDENTIFIER ::= {cnfgPrtGen 2}

prtAgendaBehaviourTable OBJECT-TYPE
     SYNTAX SEQUENCE OF PrtAgendaBehaviourEntry
     MAX-ACCESS not-accessible
     STATUS  current
     DESCRIPTION
      "The write operation into the Table Objects is valid only
       to the TmpCnfg entry."
     ::= { prtCnfgAgenda 1}

prtAgendaBehaviourEntry OBJECT-TYPE
      SYNTAX PrtAgendaBehaviourEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtAgendaBehaviourCnfgIdx, prtAgendaBehaviourSltIdx,
             prtAgendaBehaviourPrtIdx }
      ::= { prtAgendaBehaviourTable 1}

PrtAgendaBehaviourEntry ::=
      SEQUENCE {
      prtAgendaBehaviourCnfgIdx Integer32,
      prtAgendaBehaviourSltIdx  Integer32,
      prtAgendaBehaviourPrtIdx  Integer32,
      prtAgendaBehaviourOnOff   INTEGER
}

prtAgendaBehaviourCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32  (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg. "
      ::= { prtAgendaBehaviourEntry 1}

prtAgendaBehaviourSltIdx  OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This parameter should be:
 - slot number for MX3000
 - 255 = N/A  for MX300/30. "
      ::= { prtAgendaBehaviourEntry 2 }

prtAgendaBehaviourPrtIdx  OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This parameter should be:
 - port number for MX300/30
 - 100 = N/A  for MX3000. "
      ::= { prtAgendaBehaviourEntry 3 }

prtAgendaBehaviourOnOff   OBJECT-TYPE
      SYNTAX  INTEGER
              {
                notApplicable(1),
                off(2),
                on (3)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Setting this command to on(3) enables the agenda function
       at module (3000) or port (300/30) level."
      DEFVAL { off }
      ::= { prtAgendaBehaviourEntry 4 }

prtCnfgAgendaTable OBJECT-TYPE
     SYNTAX SEQUENCE OF PrtCnfgAgendaEntry
     MAX-ACCESS not-accessible
     STATUS  current
     DESCRIPTION
      "This table allows the user to schedule the time a session
        is active per week basis."
     ::= { prtCnfgAgenda 2}

prtCnfgAgendaEntry OBJECT-TYPE
      SYNTAX PrtCnfgAgendaEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX { prtCnfgAgendaCnfgIdx, prtCnfgAgendaSltIdx,
 prtCnfgAgendaPrtIdx, prtCnfgAgendaDayIdx, prtCnfgAgendaSesId }
      ::= { prtCnfgAgendaTable 1}

PrtCnfgAgendaEntry ::=
      SEQUENCE {
      prtCnfgAgendaCnfgIdx        Integer32,
      prtCnfgAgendaSltIdx         Integer32,
      prtCnfgAgendaPrtIdx         Integer32,
      prtCnfgAgendaDayIdx         INTEGER,
      prtCnfgAgendaSesId          Integer32,
      prtCnfgAgendaFrom           Integer32,
      prtCnfgAgendaTo             Integer32 
	}

prtCnfgAgendaCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32  (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg. "
      ::= { prtCnfgAgendaEntry 1}

prtCnfgAgendaSltIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute is equal to:
 -slot number for MX3000
 -255 = N/A for MX300/30"
      ::= { prtCnfgAgendaEntry 2}

prtCnfgAgendaPrtIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute is equal to:
       - port number for MX300/30
	   - port number for MX3000. For example 1-4 in MHS-4 cards.
       - 100 = N/A for MX3000 when not used."
      ::= { prtCnfgAgendaEntry 3}


prtCnfgAgendaDayIdx OBJECT-TYPE
      SYNTAX  INTEGER {
                monday   (1),
                tuesday  (2),
                wednesday(3),
                thursday (4),
                friday   (5),
                saturday (6),
                sunday   (7)
        }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute for which day of the week this row applies."
      ::= { prtCnfgAgendaEntry 4 }


prtCnfgAgendaSesId OBJECT-TYPE
      SYNTAX  Integer32 (1..4)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The user may define 4 different active intervals per day."
      ::= { prtCnfgAgendaEntry  5 }

prtCnfgAgendaFrom OBJECT-TYPE
      SYNTAX  Integer32 (0..86400)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Start from time interval in seconds."
      DEFVAL {86400}
      ::= { prtCnfgAgendaEntry 6 }

prtCnfgAgendaTo OBJECT-TYPE
      SYNTAX  Integer32 (0..86400)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "To time interval in seconds."
      DEFVAL {86400}
      ::= { prtCnfgAgendaEntry 7 }

-- General Port Configuration parameters

prtGenCnfgTable OBJECT-TYPE
     SYNTAX SEQUENCE OF PrtGenCnfgEntry
     MAX-ACCESS not-accessible
     STATUS  current
     DESCRIPTION
      "This table allows the user to configure general
       port parameters."
     ::= {cnfgPrtGen 3}

prtGenCnfgEntry OBJECT-TYPE
      SYNTAX PrtGenCnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX { prtGenCnfgIdx, prtGenCnfgSltIdx, prtGenCnfgPrtIdx }
      ::= { prtGenCnfgTable 1}

PrtGenCnfgEntry ::=
      SEQUENCE {
      prtGenCnfgIdx            Integer32,
      prtGenCnfgSltIdx         INTEGER,
      prtGenCnfgPrtIdx         Integer32,
      prtGenCnfgLinkToSlot     INTEGER,
      prtGenCnfgLinkToPort     Integer32,
	  prtGenCnfgPortId         Integer32,
	  prtGenCnfgBusConnection  INTEGER,
	  prtGenCnfgInbandMng      INTEGER,
	  prtGenCnfgInbandMngRoutProt INTEGER,
	  prtGenCnfgProtectionMode INTEGER,	 --not used
	  prtGenCnfgConnect        INTEGER,  
	  prtGenCnfgSignalingType  INTEGER  
	}

prtGenCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32  (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg.
       The write operation is valid only to the TmpCnfg."
      ::= { prtGenCnfgEntry 1}

prtGenCnfgSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
   {   clA   (3),
	   clB   (4),
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
    notApplicable (255)
   }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted."
      ::= { prtGenCnfgEntry 2}

prtGenCnfgPrtIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique external or internal port number.
     For MP:
     exPrt1    (1) .. exPrt16  (16) ,
     notApplicable(100),
     inPrt1  (101) .. inPrt84 (184) "
      ::= { prtGenCnfgEntry 3}

prtGenCnfgLinkToSlot OBJECT-TYPE
      SYNTAX  INTEGER
       {
       clA   (3),
       clB   (4),
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
    notApplicable (255)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the slot of the ML card to which
       the IO port is mapped."
      ::= { prtGenCnfgEntry 4}

prtGenCnfgLinkToPort OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the port in the prtGenCnfgLinkToSlot of
       the ML card to which the IO port is mapped.
    For MP:
     exPrt1    (1) ,
     exPrt2    (2) ,
     exPrt3    (3) ,
     exPrt4    (4) ,
     exPrt5    (5) ,
     exPrt6    (6) ,
     exPrt7    (7) ,
     exPrt8    (8) ,
     inPrt1  (101) ,
     inPrt2  (102) ,
     inPrt3  (103) ,
     inPrt4  (104) ,
	 inPrt5  (105) ,
     inPrt6  (106) ,
     inPrt7  (107) ,
     inPrt8  (108) ,
     inPrt9  (109),
     inPrt10 (110),
     inPrt11 (111),
     inPrt12 (112),
     inPrt13 (113),
     inPrt14 (114),
     inPrt15 (115),
     inPrt16 (116),
     inPrt17 (117),
     inPrt18 (118),
     inPrt19 (119),
     inPrt20 (120),
     inPrt21 (121),
     inPrt22 (122),
     inPrt23 (123),
     inPrt24 (124),
     inPrt25 (125),
     inPrt26 (126),
     inPrt27 (127),
     inPrt28 (128),
     inPrt29 (129),
     inPrt30 (130),
     inPrt31 (131),
     inPrt32 (132),
     inPrt33 (133),
     inPrt34 (134),
     inPrt35 (135),
     inPrt36 (136),
     inPrt37 (137),
     inPrt38 (138),
     inPrt39 (139),
     inPrt40 (140),
     inPrt41 (141),
     inPrt42 (142),
     inPrt43 (143),
     inPrt44 (144),
     inPrt45 (145),
     inPrt46 (146),
     inPrt47 (147),
     inPrt48 (148),
     inPrt49 (149),
     inPrt50 (150),
     inPrt51 (151),
     inPrt52 (152),
     inPrt53 (153),
     inPrt54 (154),
     inPrt55 (155),
     inPrt56 (156),
     inPrt57 (157),
     inPrt58 (158),
     inPrt59 (159),
     inPrt60 (160),
     inPrt61 (161),
     inPrt62 (162),
     inPrt63 (163),
     inPrt64 (164),
     inPrt65 (165),
     inPrt66 (166),
     inPrt67 (167),
     inPrt68 (168),
     inPrt69 (169),
     inPrt70 (170),
     inPrt71 (171),
     inPrt72 (172),
     inPrt73 (173),
     inPrt74 (174),
     inPrt75 (175),
     inPrt76 (176),
     inPrt77 (177),
     inPrt78 (178),
     inPrt79 (179),
     inPrt80 (180),
     inPrt81 (181),
     inPrt82 (182),
     inPrt83 (183),
     inPrt84 (184),
     notApplicable (255) "
      ::= { prtGenCnfgEntry 5}

prtGenCnfgPortId OBJECT-TYPE
      SYNTAX  Integer32 (0..16777215)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "IO Port Id for V5.1 use.
       This object is applicable only for part of the PSTN and ISDN IO ports.       
       Generally, 0 is a valid value.
       Nevertheless, for ports that do not support this object, the value
       will be: notApplicable= 0"
      ::= { prtGenCnfgEntry 6}

prtGenCnfgBusConnection OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable (1),
       partial       (2),
       full          (3),
	   partialCD     (4)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the support of the card regarding Bus Connection.
	   Same value for all ports of the card.
       partial = 2 Buses (AB)
       full    = 4 Buses (ABCD)
	   partial CD = 2 Buses CD
       Actually the support depends on the card's HW. But, since CL has to assign
       data on Buses even when the card is not installed, this object has to be 
       configured.
       If the actual card installed will not match the value configured, an Alarm
       will be issued."
      ::= { prtGenCnfgEntry 7}

prtGenCnfgInbandMng  OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable(1),
       off (2),
       on  (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates whether Inband Management is used over the
       link."
      ::= {prtGenCnfgEntry 8}

prtGenCnfgInbandMngRoutProt  OBJECT-TYPE
      SYNTAX  INTEGER
       {
      none           (1),
      rip2           (2),
      proprietaryRip (3),
	  notApplicable  (255)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the Inband Mng Routing Protocol of
       the port."
      ::= {prtGenCnfgEntry 9}

prtGenCnfgProtectionMode  OBJECT-TYPE
      SYNTAX  INTEGER
       {
      notApplicable (1),
      secondary     (2),
      primary       (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the Protection Mode of the port.
       notApplicable- when Bus Protection Point=No.
       For VC-4/Omni card this object is supported RO."
      ::= {prtGenCnfgEntry 10}

prtGenCnfgConnect  OBJECT-TYPE
      SYNTAX  INTEGER
       {
      no        (2),
      yes       (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates whether the port should be considered in
       any of the mux  algorithms."
      ::= {prtGenCnfgEntry 11}
      
prtGenCnfgSignalingType  OBJECT-TYPE
      SYNTAX  INTEGER
       {
      legacy       (3),
 	  abcd         (4),
	  none         (5) 
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object selects the Type of Signaling used by the port."
      ::= {prtGenCnfgEntry 12} 
       

--
-- Compressed information.
--
-- Specially for RadView management station
--
prtCmprTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtCmprEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "A table."
	::=  { cmprPrtGen 1 }

prtCmprEntry OBJECT-TYPE
      SYNTAX PrtCmprEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtCmprTypIdx, prtCmprCnfgIdx,prtCmprVersion,prtCmprSltIdx,prtCmprPrtIdx}
      ::= {prtCmprTable  1}

PrtCmprEntry ::=
      SEQUENCE {
     prtCmprTypIdx       Integer32,
     prtCmprCnfgIdx      Integer32,
     prtCmprVersion      Integer32,
     prtCmprSltIdx       INTEGER,
     prtCmprPrtIdx       Integer32,
     prtCmprObj          OCTET STRING,
	 prtCmprStatisticObj OCTET STRING
      }

prtCmprTypIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Type of the Compressed being
       referred."
      ::= { prtCmprEntry 1}

prtCmprCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the configuration to which the
       Compressed information is  related."
      ::= { prtCmprEntry 2}

prtCmprVersion OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the version of the internal format of
       the Compressed data"
      ::= { prtCmprEntry 3}

prtCmprSltIdx  OBJECT-TYPE
      SYNTAX  INTEGER
       {
       psA   (1),
       psB   (2),
       clA   (3),
       clB   (4),
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
    notApplicable (255)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique number of the slot position
       where the card is inserted.
       In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16)
       are not valid."
      ::= { prtCmprEntry 4}

prtCmprPrtIdx  OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique identifier of  the port
       the compressed information relates to.
       Valid values: exPrt1    (1) .. exPrt16  (16) ,
                     inPrt1  (101) .. inPrt48 (148)."
      ::= { prtCmprEntry 5}

prtCmprObj OBJECT-TYPE
      SYNTAX  OCTET STRING
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute is the compressed information itself."
      ::= { prtCmprEntry 6}

prtCmprStatisticObj OBJECT-TYPE
      SYNTAX  OCTET STRING
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute is the compressed statistics information itself."
      ::= { prtCmprEntry 7}


-- Compressed Dlci table in the Port level
-- The only way of reading this table is by the command 'GET NEXT'

prtDlciCmprTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtDlciCmprEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "A table."
	::=  { cmprPrtGen 2 }

prtDlciCmprEntry OBJECT-TYPE
      SYNTAX PrtDlciCmprEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtDlciCmprCnfgIdx,prtDlciCmprVersion,
             prtDlciCmprSltIdx,prtDlciCmprPrtIdx,prtDlciCmprDlciIdx}
      ::= {prtDlciCmprTable  1}

PrtDlciCmprEntry ::=
      SEQUENCE {
     prtDlciCmprCnfgIdx       Integer32,
     prtDlciCmprVersion    Integer32,
     prtDlciCmprSltIdx    INTEGER,
     prtDlciCmprPrtIdx    INTEGER,
     prtDlciCmprDlciIdx       Integer32,
     prtDlciCmprObj          OCTET STRING
      }

prtDlciCmprCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the configuration to which the
       Compressed information is  related."
      ::= { prtDlciCmprEntry 1}

prtDlciCmprVersion OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the version of the internal format of
       the Compressed data"
      ::= { prtDlciCmprEntry 2}

prtDlciCmprSltIdx  OBJECT-TYPE
     SYNTAX  INTEGER
         {
         io1   (5),
         io2   (6),
         io3   (7),
         io4   (8),
         io5   (9),
         io6  (10),
         io7  (11),
         io8  (12),
         io9  (13),
         io10 (14),
         io11 (15),
         io12 (16),
      notApplicable (255)
         }
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
     "This attribute indicates a unique number of the slot position
      where the module is inserted.
      In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16)
      are not valid."
     ::= { prtDlciCmprEntry 3}

prtDlciCmprPrtIdx  OBJECT-TYPE
     SYNTAX  INTEGER
     {
    exPrt1    (1) ,
    exPrt2    (2) ,
    exPrt3    (3) ,
    exPrt4    (4) ,
    exPrt5    (5) ,
    exPrt6    (6) ,
    exPrt7    (7) ,
    exPrt8    (8) ,
    exPrt9    (9) ,
    exPrt10  (10) ,
    inPrt1  (101) ,
    inPrt2  (102) ,
    inPrt3  (103) ,
    inPrt4  (104) ,
    inPrt5  (105) ,
    inPrt6  (106) ,
    inPrt7  (107) ,
    inPrt8  (108) ,
    inPrt9  (109) ,
    inPrt10 (110) ,
 inPrt11 (111) ,
 inPrt12 (112)
     }
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
     "This attribute indicates a unique identifier of  the port
      the compressed information relates to.
      All the values are valid."
     ::= { prtDlciCmprEntry 4}

prtDlciCmprDlciIdx  OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique identifier of  the Dlci
       the compressed information relates to.
       The values are between 16 - 991."
      ::= { prtDlciCmprEntry 5}

prtDlciCmprObj OBJECT-TYPE
      SYNTAX  OCTET STRING
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute is the compressed information itself."
      ::= { prtDlciCmprEntry 6}


-- Compressed Alarm table in the Port level
-- The only way of reading this table is by the command 'GET NEXT'

prtAlarmsCmprTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtAlarmsCmprEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "A table."
	::=  {cmprPrtGen 3}

prtAlarmsCmprEntry OBJECT-TYPE
      SYNTAX PrtAlarmsCmprEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtAlarmsCmprVersion,prtAlarmsCmprAlarmSlot,
             prtAlarmsCmprAlarmPort,prtAlarmsCmprAlarmIdx}
      ::= {prtAlarmsCmprTable  1}

PrtAlarmsCmprEntry ::=
      SEQUENCE {
     prtAlarmsCmprVersion      Integer32,
     prtAlarmsCmprAlarmSlot    Integer32,
     prtAlarmsCmprAlarmPort    Integer32,
     prtAlarmsCmprAlarmIdx     Integer32,
     prtAlarmsCmprObj          OCTET STRING
      }

prtAlarmsCmprVersion OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the version of the internal format of
       the Compressed data"
      ::= { prtAlarmsCmprEntry 1}

prtAlarmsCmprAlarmSlot  OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the  desired slot position.
       In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io(16)
       are not valid.
       For Stand-alone units, notApplicable(255) will appear."
      ::= { prtAlarmsCmprEntry 2}

prtAlarmsCmprAlarmPort  OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique identifier of  the port
       the alarm applies to.
       All the values are valid. No alarms exist for a non-existing
       port. IP Bundles are considered a port too, for this matter."
      ::= { prtAlarmsCmprEntry 3}

prtAlarmsCmprAlarmIdx  OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A unique number to identify an entry in the alarm status table
       of the agent."
      ::= { prtAlarmsCmprEntry 4}

prtAlarmsCmprObj OBJECT-TYPE
      SYNTAX  OCTET STRING
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute is the compressed information itself."
      ::= { prtAlarmsCmprEntry 5}


--
-- Specific port status for each module Type
-- *****************************************
--

-- Megaplex?000/?004 port specific status for HS(TDM) modules
-- HS-2,HS-3,HS-Q, HS-6, HS-12
prtSExHsfStatTable OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtSExHsfStatEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "A table."
	::=  {statPrtMux 6}

prtSExHsfStatEntry OBJECT-TYPE
      SYNTAX PrtSExHsfStatEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtSExHsfSltIdx, prtSExHsfPrtIdx }
      ::= {prtSExHsfStatTable 1}

PrtSExHsfStatEntry ::=
      SEQUENCE {
      prtSExHsfSltIdx           INTEGER,
      prtSExHsfPrtIdx           INTEGER,
      prtSExHsfInterfaceTyp     INTEGER,
      prtSExHsfRts              INTEGER
      }


prtSExHsfSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
        {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted.
       In the ?004 Unit the entries io6(10)..io16) are not valid."
      ::= { prtSExHsfStatEntry 1}

prtSExHsfPrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
      {
      exPrt1    (1) ,
      exPrt2    (2) ,
      exPrt3    (3) ,
      exPrt4    (4) ,
      exPrt5    (5) ,
      exPrt6    (6) ,
      exPrt7    (7) ,
      exPrt8    (8) ,
      exPrt9    (9) ,
      exPrt10  (10) ,
      exPrt11  (11) ,
      exPrt12  (12)
      }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  port number. "
      ::= { prtSExHsfStatEntry 2}

prtSExHsfInterfaceTyp OBJECT-TYPE
      SYNTAX  INTEGER
        {
         unknown     (1),
         v35         (2),
         rs422       (3)
     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique interface type of a
       selected port."
      ::= { prtSExHsfStatEntry 3}

prtSExHsfRts OBJECT-TYPE
      SYNTAX  INTEGER
        {
         unknown     (1),
         notActive   (2),
         active      (3)
     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  RTS control signal state."
      ::= { prtSExHsfStatEntry 4}



-- ISDN Port Status

prtIsdnStatusTable OBJECT-TYPE
       SYNTAX SEQUENCE OF PrtIsdnStatusEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
          "This table contains ISDN Statistics parameters that do not appear
           in the standard MIBs or for agents that don't support the standard Index
           of Call Set Up Time."
       ::= { statPrtMux 16 }
			  
prtIsdnStatusEntry OBJECT-TYPE
       SYNTAX  PrtIsdnStatusEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
           "Entries for ISDN Statistics parameters that do not appear in the standard MIBs
            or for agents that don't support the standard Index of Call Set Up Time."
       INDEX { ifIndex }
       ::= { prtIsdnStatusTable 1 }


PrtIsdnStatusEntry ::=
       SEQUENCE {
              prtIsdnStatusDspMode            INTEGER,
              prtIsdnStatusCallState          INTEGER,
			  prtIsdnStatusCallingNumber      DisplayString,
			  prtIsdnStatusCalledNumber       DisplayString,
			  prtIsdnStatusCalledIP           IpAddress,
			  prtIsdnStatusCallDirection      INTEGER
       }

prtIsdnStatusDspMode OBJECT-TYPE
       SYNTAX INTEGER
       {
          voice (2),
          idle  (3),
          fax   (4),
		  vbd   (5)
       }
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The DSP can be in one of the following Modes:
            Voice, Idle, Fax, Voice Band Data (VBD)- Modem."
       ::= { prtIsdnStatusEntry 1 }	

prtIsdnStatusCallState OBJECT-TYPE
       SYNTAX INTEGER
       {
          present            (2),
          overlapReceive     (3),
          incoming           (4),
		  receive            (5),
		  initiated          (6),
		  overlapSend        (7),
		  outGoingProceed    (8),
		  callDeliver        (9),
		  active             (10),
		  disconnectIndicate (11),
		  releaseRequest     (12),
		  disconnectReq      (13),
		  notActive          (14)
       }
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The state that the current call is in."
       ::= { prtIsdnStatusEntry 2 }

prtIsdnStatusCallingNumber OBJECT-TYPE
       SYNTAX DisplayString
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "This is the local Number (ISDN Address) associated with this entry."
       ::= { prtIsdnStatusEntry 3 }

prtIsdnStatusCalledNumber OBJECT-TYPE
       SYNTAX DisplayString
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "This is the remote Number (ISDN Address) associated with this entry."
       ::= { prtIsdnStatusEntry 4 }

prtIsdnStatusCalledIP OBJECT-TYPE
       SYNTAX IpAddress
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "This is the remote IP Address associated with this entry."
       ::= { prtIsdnStatusEntry 5 }

prtIsdnStatusCallDirection OBJECT-TYPE
       SYNTAX INTEGER
       {
          notApplicable      (1),
          incoming           (2),
          outgoing           (3)
        }
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
       "Attribute indicating the Direction of the Call.
        The value of notApplicable will be used for example when
        prtIsdnStatusCallState = notActive(14)."
       ::= { prtIsdnStatusEntry 6 }


cnfgMdlMux         OBJECT IDENTIFIER ::= {mdlMux 1}
mdlPbxFramerCnfg   OBJECT IDENTIFIER ::= {cnfgMdlMux 1}

mdlPbxFramerCnfgTable   OBJECT-TYPE
        SYNTAX SEQUENCE OF MdlPbxFramerCnfgEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
        "This table contains parameters relevant to a module belonging to
         a digital voice system, except mdlPbxFraEnhEcho which is relevant
         also for analog cards."
::= {mdlPbxFramerCnfg 1}

mdlPbxFramerCnfgEntry  OBJECT-TYPE
        SYNTAX MdlPbxFramerCnfgEntry
        MAX-ACCESS not-accessible
        STATUS current
	DESCRIPTION  "An entry in table."
	INDEX { mdlPbxFraCnfgIdx, mdlPbxFraSltIdx }
        ::=  {mdlPbxFramerCnfgTable 1}

MdlPbxFramerCnfgEntry ::=
        SEQUENCE {
                mdlPbxFraCnfgIdx Integer32,
                mdlPbxFraSltIdx  INTEGER,
                mdlPbxFraEnhEcho INTEGER,
                mdlPbxFraTSGroupAss INTEGER,
                mdlPbxFraSignalMode INTEGER,
                mdlPbxFraSignalVector OCTET STRING,
                mdlPbxFraSignalMask   OCTET STRING,
	            mdlPbxFraFramerSlot INTEGER,
				mdlPbxFraSignaling  INTEGER,
				mdlPbxFraTransSigTs Integer32 
	}

mdlPbxFraCnfgIdx OBJECT-TYPE
SYNTAX Integer32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg. "
--        DEFVAL {1}
        ::= { mdlPbxFramerCnfgEntry 1}

mdlPbxFraSltIdx OBJECT-TYPE
        SYNTAX INTEGER{ io1(5), io2(6), io3(7), io4(8), io5(9),
                        io6(10), io7(11), io8(12), io9(13), io10(14),
                        io11(15), io12(16) }
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
        "The slot relevant to this module."
        ::= { mdlPbxFramerCnfgEntry 2}

mdlPbxFraEnhEcho OBJECT-TYPE
 SYNTAX INTEGER     { notApplicable(1) ,
   disabled(2),
   ms16(3),
   ms32(4)
    }
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
        "Refers to external ports of an analogue module
        and to the internal ports of the other mvc4 types
        of modules.
        ms16(3) means that the four voice ports have enhanced
                echo of 16ms.
        ms32(4) means that the two first ports have enhanced
                echo of 32 ms while the last two ports have no
                enhanced echo."
        ::= { mdlPbxFramerCnfgEntry 3}

mdlPbxFraTSGroupAss OBJECT-TYPE
        SYNTAX INTEGER{ group1(1), group2(2), group3(3), group4(4),
                        group5(5), group6(6), group7(7), group8(8),
                        notApplicable(255) }
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
        "In case of T1 modules:
        group1=(1,2,3,4), ...., group6=(21,22,23,24)
        while in case of E1 modules:
		   - If prtExPh1MlLineType=g732sE1 or g732sE1CRC:
             group1=(1,2,3,4),..,group4=(13,14,15,17),
             group5=(18,19,20,21),...,group7=(26,27,28,29)
             group8=(30,31).
		   - If prtExPh1MlLineType=g732nE1 or g732nE1CRC:
             group1=(1,2,3,4),..,group4=(13,14,15,16),
             group5=(17,18,19,20),...,group7=(25,26,27,28)
             group8=(29,30,31)."
        ::= { mdlPbxFramerCnfgEntry 4}

mdlPbxFraSignalMode OBJECT-TYPE
        SYNTAX INTEGER { notApplicable(1),
			tieTrunk(2),
			tieInvert(3),
			casTrans(4),
            userDefined(5),
			ccsTrans(6),
			noSignaling(7)
			}
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
        "Refers to the signaling mode of the Framer module.
         tieTrunk(2), tieInvert(3), casTrans(4) are standard
        coding of the signaling protocol.

        casTrans(4) is Channel Associated Signaling (the signaling is within the
        channels time slot).
		ccsTrans(6) is Transparent Common Channel Signaling (the signaling is not within
		the channels time slot - a TS for signaling is used).

        userDefined(5) allows the user to define the signaling
        protocol he wants. In this case, the next two MIB fields
        are relevant."
        DEFVAL { casTrans }
        ::= { mdlPbxFramerCnfgEntry 5}

mdlPbxFraSignalVector OBJECT-TYPE
        SYNTAX OCTET STRING
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
        "In the case of mdlPbxFraSignalMode = userDefined(5), this
        field defines the A,B,C Bits. D bit is supplied for future
        versions.
        Bit  1 = Bit A ON Hook  - Local
        Bit  2 = Bit B ON Hook  - Local
        Bit  3 = Bit C ON Hook  - Local
        Bit  4 = Bit D ON Hook  - Local
        Bit  5 = Bit A OFF Hook - Local
        Bit  6 = Bit B OFF Hook - Local
        Bit  7 = Bit C OFF Hook - Local
        Bit  8 = Bit D OFF Hook - Local

        Bit  9 = Bit A ON Hook  - Remote
        Bit 10 = Bit B ON Hook  - Remote
        Bit 11 = Bit C ON Hook  - Remote
        Bit 12 = Bit D ON Hook  - Remote
        Bit 13 = Bit A OFF Hook - Remote
        Bit 14 = Bit B OFF Hook - Remote
        Bit 15 = Bit C OFF Hook - Remote
        Bit 16 = Bit D OFF Hook - Remote

        In conjunction with the Mask, mdlPbxFraSignalMask, it is
        possible to compute the signal mode."
        DEFVAL { '0000'H}
        ::= { mdlPbxFramerCnfgEntry 6}

mdlPbxFraSignalMask OBJECT-TYPE
        SYNTAX OCTET STRING
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
        "In the case of mdlPbxFraSignalMode = userDefined(5), this
        field defines the 'don't care' A,B,C Bits. D bit is supplied
        for future versions.
        Bit  1 = Bit A ON Hook  - Local
        Bit  2 = Bit B ON Hook  - Local
        Bit  3 = Bit C ON Hook  - Local
        Bit  4 = Bit D ON Hook  - Local
        Bit  5 = Bit A OFF Hook - Local
        Bit  6 = Bit B OFF Hook - Local
        Bit  7 = Bit C OFF Hook - Local
        Bit  8 = Bit D OFF Hook - Local

        Bit  9 = Bit A ON Hook  - Remote
        Bit 10 = Bit B ON Hook  - Remote
        Bit 11 = Bit C ON Hook  - Remote
        Bit 12 = Bit D ON Hook  - Remote
        Bit 13 = Bit A OFF Hook - Remote
        Bit 14 = Bit B OFF Hook - Remote
        Bit 15 = Bit C OFF Hook - Remote
        Bit 16 = Bit D OFF Hook - Remote."
	DEFVAL { 'ffff'H }
        ::= { mdlPbxFramerCnfgEntry 7}

mdlPbxFraFramerSlot OBJECT-TYPE
        SYNTAX INTEGER { io1(5), io2(6), io3(7), io4(8), io5(9),
                        io6(10), io7(11), io8(12), io9(13), io10(14),
                        io11(15), io12(16) }
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
        "Slot where is sitting the Framer."
     ::= { mdlPbxFramerCnfgEntry 8}

mdlPbxFraSignaling OBJECT-TYPE
        SYNTAX INTEGER {
            notApplicable   (1),
			endToEnd        (2),
			localTermination(3)
			}
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
        "Signaling - describes the way the signaling ABCD bits pass from the
		             local extension to the remote extension and vice-versa.

         endToEnd = the signaling ABCD bits pass without change from local to
                    remote extension.
         localTermination = the signaling ABCD bits received from the local extension
                    are translated to different ON Hook/OFF Hook bit values and then
                    passed to remote extension. This is relevant when the Local
                    and Remote ON Hook/OFF Hook values are different."
        DEFVAL { endToEnd }
        ::= { mdlPbxFramerCnfgEntry 9}

mdlPbxFraTransSigTs OBJECT-TYPE
        SYNTAX Integer32 
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
        "This is the Time Slot that is used for Transparent CCS signaling.
         The values of this TS are 1-24 for T1 & 1-31 for E1.
         The default for E1 is 16 & for T1 it is 24. If no signaling is used then
         the TS should be 255 (None)."
        ::= { mdlPbxFramerCnfgEntry 10}

--Protected IP Adresses list for ML-IP cards of MP-2100/4 and MP-2200
--for IP Ring Mode

mdlProtIpTable   OBJECT-TYPE
      SYNTAX SEQUENCE OF MdlProtIpEntry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
      "This table contains Protected IP Addresses for ML-IP cards
       when working in IP Ring Mode."
      ::= {cnfgMdlMux 2}

mdlProtIpEntry  OBJECT-TYPE
      SYNTAX MdlProtIpEntry
      MAX-ACCESS not-accessible
      STATUS current
	  DESCRIPTION  "An entry in table."
	  INDEX { mdlProtIpCnfgIdx, mdlProtIpSlotIdx, mdlProtIpAddress}
      ::=  {mdlProtIpTable 1}

MdlProtIpEntry ::=
      SEQUENCE {
       mdlProtIpCnfgIdx   Integer32,
       mdlProtIpSlotIdx   INTEGER,
       mdlProtIpAddress   IpAddress,
       mdlProtIpRowStatus RowStatus
	}

mdlProtIpCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg being accessed.
       Idx 255 relates to the TmpCnfg.
       For Agents having several configuration, Write operation is
       allowed only to the Temporary Configuration."
      ::= { mdlProtIpEntry 1}

mdlProtIpSlotIdx OBJECT-TYPE
      SYNTAX  INTEGER
      {
       notApplicable (1),
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
      }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the module is inserted.
       In the 2104 Unit the entries io6(10)..io16) are not valid."
      ::= { mdlProtIpEntry 2}

mdlProtIpAddress OBJECT-TYPE
      SYNTAX  IpAddress 
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A Protected IP address."
      ::= { mdlProtIpEntry 3 }

mdlProtIpRowStatus  OBJECT-TYPE
      SYNTAX  RowStatus
      MAX-ACCESS   read-create
      STATUS   current
      DESCRIPTION
      "This parameter allows creating/deleting entries of this table."
      ::= { mdlProtIpEntry 4 }


statMdlMux  OBJECT IDENTIFIER ::= {mdlMux 2}

--
-- Card status table
--
mdlStatTable  OBJECT-TYPE
    SYNTAX SEQUENCE OF MdlStatEntry
    MAX-ACCESS not-accessible
    STATUS current
	DESCRIPTION  "A table."
	::=  { statMdlMux 1 }

mdlStatEntry OBJECT-TYPE
    SYNTAX MdlStatEntry
    MAX-ACCESS not-accessible
    STATUS current
	DESCRIPTION  "An entry in table."
	INDEX { mdlStatSltIdx }
      ::= { mdlStatTable 1}

MdlStatEntry ::=
      SEQUENCE {
     mdlStatSltIdx         INTEGER,
     mdlStatHostIP         IpAddress,
     mdlStatHostMask       IpAddress,
     mdlStatDefaultGateway IpAddress
      }

mdlStatSltIdx OBJECT-TYPE
   SYNTAX  INTEGER
   {
       psA   (1),
       psB   (2),
       clA   (3),
       clB   (4),
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
   }
   MAX-ACCESS  read-only
   STATUS  current
   DESCRIPTION
   "A unique number to identify a slot position in the mux.
    In the 2104 Unit the entries psB(2),clB(4),io6(10)..io12(16)
    are not valid."
   ::= { mdlStatEntry 1}

mdlStatHostIP OBJECT-TYPE
    SYNTAX  IpAddress 
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
    "The host interface IP address when DHCP Client=Yes.
     This object is relevant only when DHCP Client=Yes "
    ::= { mdlStatEntry 2 }

mdlStatHostMask OBJECT-TYPE
    SYNTAX  IpAddress 
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
    "The host interface subnet mask when DHCP Client=Yes.
     This object is relevant only when DHCP Client=Yes "
    ::= { mdlStatEntry 3 }

mdlStatDefaultGateway OBJECT-TYPE
    SYNTAX  IpAddress
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
    "Default Gateway's IP Address when DHCP Client=Yes.
     This object is relevant only when DHCP Client=Yes "
    ::= { mdlStatEntry 4 }


--
-- Specific port config for each module Type
-- *****************************************

--
-- MPCL.1 configuration parameters
--
--prtExClCnfgTable   OBJECT IDENTIFIER ::= {prtClCnfg 1}
-- prtInClInbandTable OBJECT IDENTIFIER ::= {prtClCnfg 2}

prtExClCnfgTable OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtExClCnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "A table."
	::=  {prtClCnfg 1}

prtExClCnfgEntry OBJECT-TYPE
      SYNTAX PrtExClCnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
      "All the entries at this table are identical (have the same
       value) for all the configurations (1..100) except the
       TmpCnfg.
       The write operation into the Table Objects is valid only
       to the TmpCnfg entry."
      INDEX {prtExClCnfgIdx, prtExClSltIdx, prtExClPrtIdx }
      ::= { prtExClCnfgTable 1}

PrtExClCnfgEntry ::=
      SEQUENCE {
      prtExClCnfgIdx         Integer32,
      prtExClSltIdx          INTEGER,
      prtExClPrtIdx          INTEGER,
   prtExClUsage           INTEGER,
   prtExClRate            INTEGER,
   prtExClDataBits        INTEGER,
   prtExClParity          INTEGER,
   prtExClStopBits        INTEGER,
   prtExClRoutingProtocol INTEGER,
   prtExClEnabled         INTEGER
      }


prtExClCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg."
      ::= { prtExClCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.

prtExClSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
        {
       clA   (3),
       clB   (4),
       notApplicable (255)
        }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted. Because the second Cl is only for
       redundancy, all the parameters are identical in the two
       modules, i.e. change of any parameter in one module will
       change automatically the value of the other module..
       In the ?004 Unit the entry clB(4) is not valid."
      ::= { prtExClCnfgEntry 2}

prtExClPrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
      {
  exPrt1    (1) ,
  exPrt2    (2)
      }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  port number. "
      ::= { prtExClCnfgEntry 3}

prtExClUsage OBJECT-TYPE
      SYNTAX  INTEGER
       {
  unknown (1),
  noUse   (2),
  nmsSlip (3),
  nmsPpp  (4),
  muxSlip (5),
  muxPpp  (6),
  terminal(7)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates what is the usage of the port."
      ::= { prtExClCnfgEntry 4}

prtExClRate OBJECT-TYPE
      SYNTAX  INTEGER
       {
        r300Bps (1),
        r1200Bps (2),
        r2400Bps (3),
        r4800Bps (4),
        r9600Bps (5),
        r19200Bps (6),
        r38400Bps (7),
        r57600Bps (8),
        r115200Bps (9)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the operation rate of the port."
      ::= { prtExClCnfgEntry 5}

prtExClDataBits OBJECT-TYPE
      SYNTAX  INTEGER
       {
        dataBits7Bits (1),
        dataBits8Bits (2)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the number of data bits in async
       frame"
      ::= { prtExClCnfgEntry 6}

prtExClParity OBJECT-TYPE
      SYNTAX  INTEGER
       {
        odd   (1),
        even  (2),
        none  (3)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates if the parity operation mode in
       async frame"
      ::= { prtExClCnfgEntry 7}

prtExClStopBits OBJECT-TYPE
      SYNTAX  INTEGER
       {
          stopBits1Bit      (1),
          stopBits1dot5Bits (2),
          stopBits2Bits     (3)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the minimum number of stop bits in
       the tx async frame"
      ::= { prtExClCnfgEntry 8}

prtExClRoutingProtocol OBJECT-TYPE
      SYNTAX  INTEGER
       {
       none    (1),
       rip2    (2)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the routing protocol of the port.
       When prtExClUsage is nmsSlip or nmsPpp - all values are
                                                applicable .
       Else - only 'none' is applicable."
      ::= { prtExClCnfgEntry 9}

prtExClEnabled OBJECT-TYPE
      SYNTAX  INTEGER
       {
      notApplicable(1),
      disabled     (2),
	  enabled      (3)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates if Ethernet port of CL
       is enabled or not for management.
       It is applicable only on the ETH port of the CL, when the 
       MP includes an ML-IP card.
       disabled - will happen when there is Inband Management via
	              the ML-IP link/s
	   enabled  - will happen when ML-IP link/s is not used for Inband 
	              Management, but CL's ETH port ."
      ::= { prtExClCnfgEntry 10}

--
-- MPH1.T1, MPH1.E1, MTML.1/T1 , MTML.1/E1, ML-20
-- TDM and Hybrid(TDM & Packet) Main Link Modules
--
--prtExPh1MlCnfgTable OBJECT IDENTIFIER ::= {prtPh1MlCnfg 1}
--prtExPh1MlTsTable   OBJECT IDENTIFIER ::= {prtPh1MlCnfg 2}
--prtInPh1MlCnfgTable OBJECT IDENTIFIER ::= {prtPh1MlCnfg 3}
--prtInPh1MlDlciTable OBJECT IDENTIFIER ::= {prtPh1MlCnfg 4}
--prtPhMlCnfgTable    OBJECT IDENTIFIER ::= {prtPh1MlCnfg 5}

--
-- T1/E1 Port Objects
--
prtExPh1MlCnfgTable  OBJECT-TYPE
     SYNTAX SEQUENCE OF PrtExPh1MlCnfgEntry
     MAX-ACCESS not-accessible
     STATUS  current
     DESCRIPTION
      "- For products supporting more than one configuration, the write operation 
         into the Table is valid only to the TmpCnfg entry.
       - For products that do not support configurations, the write operation 
         into the Table will be to prtExPh1MlCnfgIdx=1."
     ::= {prtPh1MlCnfg 1}

prtExPh1MlCnfgEntry OBJECT-TYPE
      SYNTAX PrtExPh1MlCnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
    DESCRIPTION  "An entry in table."
    INDEX {prtExPh1MlCnfgIdx, prtExPh1MlSltIdx, prtExPh1MlPrtIdx }
      ::= { prtExPh1MlCnfgTable 1}

PrtExPh1MlCnfgEntry ::= SEQUENCE {
    prtExPh1MlCnfgIdx        Integer32,
    prtExPh1MlSltIdx         INTEGER,
    prtExPh1MlPrtIdx         INTEGER,
      prtExPh1MlConnect        INTEGER,
      prtExPh1MlLineType       INTEGER,
    prtExPh1MlLineCode       INTEGER,
      prtExPh1MlLineLen        INTEGER,
      prtExPh1MlRestoreTime    INTEGER,
      prtExPh1MlTxGain         INTEGER,
      prtExPh1MlRxSensitivity  INTEGER,
      prtExPh1MlIdleCode       Integer32,
      prtExPh1MlTdmTrunk       INTEGER,
      prtExPh1MlClkMode        INTEGER,
      prtExPh1MlMfClkSrcSlt    INTEGER,
      prtExPh1MlMfClkSrcPrt    INTEGER,
      prtExPh1MlFdlType        INTEGER,
      prtExPh1MlInbandMng      INTEGER,
      prtExPh1MlInbandMngRate  INTEGER,
      prtExPh1MlRedundType     INTEGER,
      prtExPh1MlRedundSlot     INTEGER,
      prtExPh1MlRedundPort     INTEGER,
      prtExPh1MlRedundRecTime  Integer32,
   prtExPh1MlInbandMngRoutProt INTEGER,
      prtExPh1MlIfType         INTEGER,
	  prtExPh1MlMultiplier     INTEGER,
	  prtExPh1MlSupportedTS    Integer32,
	  prtExPh1MlImpedance      INTEGER,
	  prtExPh1MlQ50BwControl   INTEGER,	  
	  prtExPh1MlQ50SignalPair  INTEGER,
	  prtExPh1MlInternalSwitch INTEGER,
	  prtExPh1MlSigService     INTEGER,
	  prtExPh1MlFragmentSize   Integer32
 }

prtExPh1MlCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg. "
      ::= { prtExPh1MlCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.

prtExPh1MlSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
     {
       notApplicable (1),
       clA   (3),
       clB   (4),
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the module is inserted.
       In the ?004 Unit the entries io6(10)..io16) are not valid.
       For the Vmux2100 Main Board notApplicable (1) is used."
      ::= { prtExPh1MlCnfgEntry 2}

prtExPh1MlPrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
       {
       exPrt1     (1),
       exPrt2     (2),
       exPrt3     (3),
       exPrt4     (4),
       exPrt5     (5),
       exPrt6     (6),
       exPrt7     (7),
       exPrt8     (8),
       exPrt9     (9),
       exPrt10   (10),
       exPrt11   (11),
       exPrt12   (12),
       exPrt13   (13),
       exPrt14   (14),
       exPrt15   (15),
       exPrt16   (16),
       exPrt17   (17),
       exPrt18   (18),
       inPrt1   (101),
       inPrt2   (102),
       inPrt3   (103),
       inPrt4   (104),
       inPrt5   (105),
       inPrt6   (106),
       inPrt7   (107),
       inPrt8   (108),
       inPrt9   (109),
       inPrt10  (110),
       inPrt11  (111),
       inPrt12  (112),
       inPrt13  (113),
       inPrt14  (114),
       inPrt15  (115),
       inPrt16  (116),
       inPrt17  (117),
       inPrt18  (118),
       inPrt19  (119),
       inPrt20  (120),
       inPrt21  (121),
       inPrt22  (122),
       inPrt23  (123),
       inPrt24  (124),
       inPrt25  (125),
       inPrt26  (126),
       inPrt27  (127),
       inPrt28  (128),
       inPrt29  (129),
       inPrt30  (130),
       inPrt31  (131),
       inPrt32  (132),
       inPrt33  (133),
       inPrt34  (134),
       inPrt35  (135),
       inPrt36  (136),
       inPrt37  (137),
       inPrt38  (138),
       inPrt39  (139),
       inPrt40  (140),
       inPrt41  (141),
       inPrt42  (142),
       inPrt43  (143),
       inPrt44  (144),
       inPrt45  (145),
       inPrt46  (146),
       inPrt47  (147),
       inPrt48  (148),
       inPrt49  (149),
       inPrt50  (150),
       inPrt51  (151),
       inPrt52  (152),
       inPrt53  (153),
       inPrt54  (154),
       inPrt55  (155),
       inPrt56  (156),
       inPrt57  (157),
       inPrt58  (158),
       inPrt59  (159),
       inPrt60  (160),
       inPrt61  (161),
       inPrt62  (162),
       inPrt63  (163),
       inPrt64  (164),
       inPrt65  (165),
       inPrt66  (166),
       inPrt67  (167),
       inPrt68  (168),
       inPrt69  (169),
       inPrt70  (170),
       inPrt71  (171),
       inPrt72  (172),
       inPrt73  (173),
       inPrt74  (174),
       inPrt75  (175),
       inPrt76  (176),
       inPrt77  (177),
       inPrt78  (178),
       inPrt79  (179),
       inPrt80  (180),
       inPrt81  (181),
       inPrt82  (182),
       inPrt83  (183),
       inPrt84  (184)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  port number.
       MP-2100/2200:
       MTML-1/E1 and MTML-1/T1 cards have only one external interface.
       inPrt1, inPrt2 - for MTML-H/2E1 and HSH cards.
       inPrt1..inPrt4 - for MTML-E2 and MSL-4 cards.
       exPrt2..exPrt4 - for MTML-4 cards and others
       exPrt1..exPrt8 - for ML-8 cards.
       inPrt1..inPrt8 - for MSL-8 and VF-30 card family.
       MP-104/204:  only exPrt3 (3) is applicable.
       MP-4100:     intPrt1...intPrt84 - for CLX cards.
       For other products' index see their specification."
      ::= { prtExPh1MlCnfgEntry 3}

prtExPh1MlConnect OBJECT-TYPE
      SYNTAX  INTEGER
       {
        no  (2),
        yes (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the port should be considered
       in any of the mux  algorithms. It also affects all the card
       considerations because it may indicate that the module has only
       one physical interface."
      ::= {prtExPh1MlCnfgEntry 4}

prtExPh1MlLineType OBJECT-TYPE
      SYNTAX  INTEGER
       {
        esfT1          (2), --> dsx1ESF
        sfT1           (3), --> dsx1D4
        g732nE1        (4), --> dsx1E1
        g732nE1CRC     (5), --> dsx1E1-CRC
        g732sE1        (6), --> dsx1E1-MF
        g732sE1CRC     (7), --> dsx1E1-MF-CRC
        g732unframed   (8), --> dsx1Unframed, for T1 Unframed
		e1Unframed     (9), --> dsx1E1Unframed
		framed       (101)  
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute is the line type parameter for T1/E1 interface.
       The user should select only the values which are relevant
       to the specific port:
       (2),(3), (8)  - for T1 port
       (4)..(7), (9) - for E1 port.
	   (101) framed - This value does not exist	in standard MIB and is used 
	                  for a non-standard E1 port that doesn't has real framer.
	   Note: for old devices, g732unframed(8) was used as E1 Unframed.
	         That was because at the time this value did not exist in
	         the standard MIB (RFC-1406), so we added it in private MIB.
	         Now that it was added to standard MIB, private MIB was 
	         updated as well.   
       This parameter has the same values as dsx1LineType in DS1
       MIB (RFC-3895). The parameters in dsx1LineType are:
                     other          (1)
      esfT1          dsx1ESF        (2)
      sfT1           dsx1D4         (3)
      g732nE1        dsx1E1         (4)
      g732nE1CRC     dsx1E1-CRC     (5)
      g732sE1        dsx1E1-MF      (6)
      g732sE1CRC     dsx1E1-MF-CRC  (7)
      g732unframed   dsx1Unframed   (8)	--from RFC-3895
      e1Unframed     dsx1E1Unframed (9) --from RFC-3895 "
      ::= { prtExPh1MlCnfgEntry 5}

prtExPh1MlLineCode OBJECT-TYPE
      SYNTAX  INTEGER
       {
        b7T1   (1),  --> dsx1JBZS (for E1 & T1)
        b8zsT1 (2),  --> dsx1B8ZS (for E1 & T1)
        transT1(3),  --> dsx1AMI
        hdb3E1 (4),  --> dsx1HDB3 (for E1 & T1)
        notApplicable(255)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute is the line code parameter used for T1/E1
       interface.
       The user should select only the parameters which are relevant
       to the specific card:
       T1 line code parameters for MPH.1/T1
       E1 line code parameters for MPH.1/E1.
       This parameter has the same values as dsx1LineCoding in T1/E1
       MIB (RFC-1406).  The parameters in dsx1LineCoding are:
       dsx1JBZS  (1)
       dsx1B8ZS  (2)
       dsx1HDB3  (3)
       dsx1ZBTSI (4)
       dsx1AMI   (5)
       other     (6)"
      ::= { prtExPh1MlCnfgEntry 6}

prtExPh1MlLineLen OBJECT-TYPE
      SYNTAX  INTEGER
       {
        unknown      (1),
        len0p133ft   (2),
        len134p266ft (3),
        len267p399ft (4),
        len400p533ft (5),
        len534p655ft (6),
        lenFcc68     (7),
        notApplicable(255)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute is the line length parameter used only for T1/DSU
       interfaces.
       lenXXXpXXXft = len-XXX-XXXft."
      ::= { prtExPh1MlCnfgEntry 7}

prtExPh1MlRestoreTime OBJECT-TYPE
      SYNTAX  INTEGER
       {
        restoreT1secFast      (2),
        restoreT10sec62411    (3),
        ccittE1                (4)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The time passing from the disappearance of the loss of
       synchronization condition (red alarm) to the restoration of
       normal service. The options 1secFast(2) and 10sec62411(3)
       for E1 interfaces are proprietary implementation of the T1
       standard to the E1 interface."
      ::= { prtExPh1MlCnfgEntry 8}

prtExPh1MlTxGain OBJECT-TYPE
      SYNTAX  INTEGER
       {
          notApplicable(1),
          txGain0db         (2),
          txGain7dot5db     (3),
          txGain15db        (4),
          txGain22dot5db    (5)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute is the tx gain parameter used only for
       T1/CSU interfaces."
      ::= { prtExPh1MlCnfgEntry 9}

prtExPh1MlRxSensitivity OBJECT-TYPE
      SYNTAX  INTEGER
       {
        notApplicable(1),
        low26dBm  (2),
        high36dBm (3),
        shortHaul (4),
        longHaul  (5),
        low15dbm  (6)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute is the rx line sensitivity parameter.
       low26dBm, high36dBm - applicable for T1-CSU
       shortHaul, longHaul - applicable for MTML-4 cards
       low15dbm was added for vmux110/210 T1 ports."
      ::= { prtExPh1MlCnfgEntry 10}

prtExPh1MlIdleCode OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
     "Determines the code for transmission in empty time slots.
      Type value(00-FFH), Excluding 0H,8H,10H,12H,21H,24H,42H,49H,
      84H,92H"
      ::= { prtExPh1MlCnfgEntry 11}

prtExPh1MlTdmTrunk  OBJECT-TYPE
      SYNTAX  INTEGER
       {
        linkA   (1),
        linkB   (2),
        none    (3),
        notApplicable (255)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the port is used to transfer
       TDM cards data and through which Bus."
      ::= {prtExPh1MlCnfgEntry 12}

prtExPh1MlClkMode OBJECT-TYPE
      SYNTAX  INTEGER
       {
        internalLocal (1),
        loopBackLocal (2),
        nodalTiming   (3),
		loopBackFromLink (4),
		loopBackFromChannel (5),
		loopbackFromSystem (6)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Defines the clock operation mode of the T1/E1 interface.
       Ports that are connected to the TDM Buses must be in
       nodalTiming(3) clock mode. "
      ::= {prtExPh1MlCnfgEntry 13}

prtExPh1MlMfClkSrcSlt  OBJECT-TYPE
      SYNTAX  INTEGER
       {
          notApplicable(1),
          local (2),
          io1   (5),
          io2   (6),
          io3   (7),
          io4   (8),
          io5   (9),
          io6  (10),
          io7  (11),
          io8  (12),
          io9  (13),
          io10 (14),
          io11 (15),
          io12 (16)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the port Tx multiframe is
       synchronized with Rx multiframe of another port and the slot
       position of that port.
       This operation is required in order to bypass signaling of
       PCM voice channels. Its value is always local(2) when the port
       isn't connected to any TDM bus. When it's value is local(2)
       there is no meaning to 'prtExPh1MlMfClkSrcPrt' parameter.
       In the ?004 Unit the entries io6(10)..io16) are not valid"
      ::= {prtExPh1MlCnfgEntry 14}

prtExPh1MlMfClkSrcPrt  OBJECT-TYPE
      SYNTAX  INTEGER
       {
          exPrt1         (1),
		  exPrt2         (2),
          inPrt1       (101),
          notApplicable(255)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "A unique number to identify a port position in the mux. It
       has no effect when the prtExPh1MlMfClkSrcSlt selected is Local.
       inPrt1 - for MTML-H/E1 cards."
    ::= {prtExPh1MlCnfgEntry 15}

prtExPh1MlFdlType  OBJECT-TYPE
      SYNTAX  INTEGER
       {
          notApplicable(1),
          response   (2),
          command    (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "A unique number to identify  the side of the FDL operation.
      Normal: 'response' for the user side and 'command' for the PTT
      side.
      Applicable only when working with ESF-T1 link"
      ::= {prtExPh1MlCnfgEntry 16}

prtExPh1MlInbandMng  OBJECT-TYPE
      SYNTAX  INTEGER
       {
       off                 (2),
       fdlOrTs0            (3),
       dedicatedTs         (4),
       dedicatedPpp        (5),
       dedicatedFr         (6),
       notApplicable     (255)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "A unique number to identify an Inband management over the
       link."
      ::= {prtExPh1MlCnfgEntry 17}

prtExPh1MlInbandMngRate  OBJECT-TYPE
      SYNTAX  INTEGER
       {
          notApplicable(1),
          r4k   (2),
          r8k   (3),
          r12k  (4),
          r16k  (5),
          r32k  (6),
          r64k  (7),
          r20k  (8)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "A unique number to identify the rate of the Inband
       management (Kbps).
       E1 port - it is not applicable when prtExPh1MlInbandMng
                 selected is off.
       T1 port - it is not applicable when prtExPh1MlInbandMng
                 selected is off OR fdlOrTs0."
      ::= {prtExPh1MlCnfgEntry 18}

prtExPh1MlRedundType  OBJECT-TYPE
      SYNTAX  INTEGER
       {
          none                (1),
          dualCableAIS        (2),
          yCable              (3),
          dualCableParallelTx (4)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object determines the ML redundancy type:
       none - no ML redundacy
       dualCableAIS -        each ML card is connected by a separate
       dualCableParallelTx   cable to the other MUX (two cables
                             connect two MUXes).  There are two
                             types of dual redundancy.
       yCable - Y cable is connected to both ML cards (one cable
                connects two MUXes).
       Default=none
       When only one ML card exists, the type can be only 'none'.
       The value should be the same for both ML slots."
      ::= {prtExPh1MlCnfgEntry 19}

prtExPh1MlRedundSlot  OBJECT-TYPE
      SYNTAX  INTEGER
       {
          notApplicable (1),
          io1   (5),
          io2   (6),
          io3   (7),
          io4   (8),
          io5   (9),
          io6  (10),
          io7  (11),
          io8  (12),
          io9  (13),
          io10 (14),
          io11 (15),
          io12 (16)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the slot containing the redundacy ML
       card, coupled with the current ML (prtExPh1MlSltIdx).
       When prtExPh1MlRedundType=none (no ML redundancy) this
       object will be 'notApplicable'.
       In the ?004 Unit the entries io6(10)..io12(16) are not valid
       When value is not 'none', it should be mutual to the
       redundant ML slot."
      ::= {prtExPh1MlCnfgEntry 20}

prtExPh1MlRedundPort  OBJECT-TYPE
      SYNTAX  INTEGER
       {
       exPrt1          (1),
       exPrt2          (2),
       exPrt3          (3),
       exPrt4          (4),
       inPrt1        (101),
       inPrt2        (102),
       inPrt3        (103),
       inPrt4        (104),
       notApplicable (255)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the redundacy ML port, coupled with the
       current ML port (prtExPh1MlPrtIdx).
       When prtExPh1MlRedundType=none (no ML redundancy) this
       object will be 'notApplicable'.
       When value is not 'none', it should be mutual to the
       redundant ML port.
       inPrt1 - for MTML-H/E1 cards.
       inPrt1..inPrt4 - for MTML-E2 cards.
       exPrt2..exPrt4 - for MTML-4 cards."
      ::= {prtExPh1MlCnfgEntry 21}

prtExPh1MlRedundRecTime  OBJECT-TYPE
      SYNTAX  Integer32  (1..99)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Redundancy Recovery Time (sec). After switching the ML card
       to the current (prtExPh1MlSltIdx), the next ML switch can
       be performed only after a minimum time, indicated by
       this object."
      ::= {prtExPh1MlCnfgEntry 22}

prtExPh1MlInbandMngRoutProt  OBJECT-TYPE
      SYNTAX  INTEGER
       {
      none    (1),
      rip2    (2),
      proprietary        (3),
	  proprietaryNoNmsTx (4)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Inband Mng routing protocol of
       the port."
      ::= {prtExPh1MlCnfgEntry 23}

prtExPh1MlIfType  OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable (1),
       csu    (2),
       dsu    (3),
	   ltu    (4)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Interface type of the port.
       For T1 - csu, dsu are the valid values
       For E1 - dsu, ltu are the valid values."
      ::= {prtExPh1MlCnfgEntry 24}

prtExPh1MlMultiplier  OBJECT-TYPE
      SYNTAX  INTEGER { 
      notApplicable (1), 
      br56 (2),
      br64 (3)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The data rate of each TS. The multiplier values
       can be 56 kbps or 64 kbps."
      ::= {prtExPh1MlCnfgEntry 25}

prtExPh1MlSupportedTS  OBJECT-TYPE
      SYNTAX  Integer32 
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Number of Supported Time Slots by the agent.
       For Vmux-110 there is HW that supports less than 31/24
       Time Slots for the E1/T1 port."
      ::= {prtExPh1MlCnfgEntry 26}

prtExPh1MlImpedance  OBJECT-TYPE
      SYNTAX  INTEGER { 
      notApplicable (1), 
      unbalanced    (2),
      balanced      (3)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The Line Impedance.
       For T1 (always balanced), impedance is 100 ohm.
       For E1:
       - balanced   = 120 ohm
       - unbalanced =  75 ohm."
      ::= {prtExPh1MlCnfgEntry 27}

prtExPh1MlQ50BwControl  OBJECT-TYPE
      SYNTAX  INTEGER { 
      disable       (2),
      annexA        (3),
      annexB        (4)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object enables configuration of Q.50 Bandwidth Control on the port.
	   If the bandwidth exceeds a certain threshold it is possible to disable
	   new calls in the PBX via Q.50 protocol.

	   Q.50 supports only E1 ports with Line Types:
	   E1-MF (G.732S), E1-CRC-MF(G.732SCRC ) 	   
	   It does not support T1 ports.
	   
	   Annex A - the basic type of Q.50 which focuses only on the bandwidth control.
       Can use one of the following pairs of signaling bits: A&B or C&D.

       Annex B - Expansion of Annex A which includes also call release messages
       and Maintenance Messages. Uses A&B bits only."
      ::= {prtExPh1MlCnfgEntry 28}

prtExPh1MlQ50SignalPair  OBJECT-TYPE
      SYNTAX  INTEGER { 
      notApplicable (1), 
      aAndB         (2),
      cAndD         (3)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Q.50 Signaling bits Pair that is currently in use:
       A&B bits or C&D bits. For Annex B it will always be: aAndB (2)."
      ::= {prtExPh1MlCnfgEntry 29}

 prtExPh1MlInternalSwitch  OBJECT-TYPE
      SYNTAX  INTEGER { 
      disable      (2),
      enable       (3)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This parameter shows whether the data will be transferred from one port to
       the other port within the same group of 2 ports.
	   The default value is: Enable.
	   Disable value might be necessary for security implementations or
	   for ring applications.
      
       For Vmux-2100 device this parameter is used on the Channelized Cards.
       Both ports in each group should have the same value for this parameter."
      ::= {prtExPh1MlCnfgEntry 30}

 prtExPh1MlSigService  OBJECT-TYPE
      SYNTAX  INTEGER {
      notApplicable(1), 
      normal       (2),
      advanced     (3)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Signaling Service given by this link.
       notApplicable - for T1 links 
       normal - usual Signaling
       advanced - V5 Signaling. "
      ::= {prtExPh1MlCnfgEntry 31}

prtExPh1MlFragmentSize  OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This parameter indicates the maximum number of bytes permitted in a packet send over the Link.
      Exceeding this size will cause packet fragmentation."
      ::= {prtExPh1MlCnfgEntry 32}
--
-- MPH1.T1 & MPH1.E1
-- Time Slot Assignment Table
--
prtExPh1MlTsTable  OBJECT-TYPE
     SYNTAX SEQUENCE OF PrtExPh1MlTsEntry
     MAX-ACCESS not-accessible
     STATUS  current
     DESCRIPTION
      "The write operation into the Table Objects is valid only
       to the TmpCnfg entry, except prtExPh1MlTsTest that will be written
       directly to the Active Configuration."
     ::= {prtPh1MlCnfg 2}

prtExPh1MlTsEntry OBJECT-TYPE
      SYNTAX PrtExPh1MlTsEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtExPh1MlTsCnfgIdx, prtExPh1MlTsSltIdx, prtExPh1MlTsPrtIdx, prtExPh1MlTsIdx }
      ::= { prtExPh1MlTsTable 1}

PrtExPh1MlTsEntry ::=
      SEQUENCE {
      prtExPh1MlTsCnfgIdx        Integer32,
      prtExPh1MlTsSltIdx         INTEGER,
      prtExPh1MlTsPrtIdx         INTEGER,
      prtExPh1MlTsIdx            Integer32,
      prtExPh1MlTsIConSlot       INTEGER,
      prtExPh1MlTsIConPrt        Integer32,
      prtExPh1MlTsIConTs         Integer32,
      prtExPh1MlTsExt    		 OBJECT IDENTIFIER,
	  prtExPh1MlTsTest           INTEGER,
	  prtExPh1MlTsType           INTEGER,
	  prtExPh1MlTsBundle         Integer32,
	  prtExPh1MlTsTestDuration   Integer32,
	  prtExPh1MlTsSubChType      INTEGER,
	  prtExPh1MlTsSubChMask      Integer32,
	  prtExPh1MlTsChRate      	 INTEGER,
	  prtExPh1MlTsByteReversal   INTEGER,
	  prtExPh1MlTsSigProfile     INTEGER
      }

prtExPh1MlTsCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32  (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg. "
      ::= { prtExPh1MlTsEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.

prtExPh1MlTsSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
     {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
	   notApplicable (255)
     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted.
       In the ?004 Unit the entries io6(10)..io16) are not valid.
       For the Vmux2100 Main Board notApplicable (255) is used."
      ::= { prtExPh1MlTsEntry 2}

prtExPh1MlTsPrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
	{
          exPrt1    (1),
	  exPrt2    (2),
	  exPrt3    (3),
	  exPrt4    (4),
          exPrt5    (5),
	  exPrt6    (6),
	  exPrt7    (7),
	  exPrt8    (8),
          exPrt9    (9),
	  exPrt10    (10),
	  exPrt11    (11),
	  exPrt12    (12),
          exPrt13    (13),
	  exPrt14    (14),
	  exPrt15    (15),
	  exPrt16    (16),
	  exPrt17    (17),
	  exPrt18    (18),

	  inPrt1    (101),
	  inPrt2    (102),
	  inPrt3    (103),
	  inPrt4    (104),
          inPrt5    (105),
	  inPrt6    (106),
	  inPrt7    (107),
	  inPrt8    (108),
          inPrt9    (109),
	  inPrt10   (110),
	  inPrt11   (111),
	  inPrt12   (112),
          inPrt13   (113),
	  inPrt14   (114),
	  inPrt15   (115),
	  inPrt16   (116),
	  inPrt17   (117),
	  inPrt18   (118),
	  inPrt19   (119),
	  inPrt20   (120)	      }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  port number.
       MPH.1/E1 and MPH.1/T1 cards have only one external interface.
	   exPrt2 - for ME1-2, MT1-2 and mhsPri cards.
	   exPrt3, exPrt4 - for mhsPri cards.
       inPrt1 - for MTML-H/E1 cards."
      ::= { prtExPh1MlTsEntry 3}

prtExPh1MlTsIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique time slot  position.
       The valid time slots are 1..24 for T1 Card and
       1..31 for E1 interface. In G732S-E1 lines time slot 16 is not
       valid for data, it is dedicated for multiframe synchronization bits
       and voice signaling."
      ::= { prtExPh1MlTsEntry 4}

prtExPh1MlTsIConSlot OBJECT-TYPE
      SYNTAX  INTEGER
       {
          unknown   (1),		  
          noConnect (2),
          split     (4),
          io1       (5),
          io2       (6),
          io3       (7),
          io4       (8),
          io5       (9),
          io6      (10),
          io7      (11),
          io8      (12),
          io9      (13),
          io10     (14),
          io11     (15),
          io12     (16),
		  notApplicable (255)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the specified time slot is
       connected/routed internally in the Agent and to which card
       it is connected.
       In the ?004 Unit the entries io6(10)..io16) are not valid.
       split - will be used when the Src TS is connected to more
               than one slot OR more than one port (each needing
               less than a whole TS)."
      ::= {prtExPh1MlTsEntry 5}

prtExPh1MlTsIConPrt OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the internally (In Mux)
       connected/routed port.
       For MP, the values will be:
       	      {
	      exPrt1    (1) ,
	      exPrt2    (2) ,
	      exPrt3    (3) ,
	      exPrt4    (4) ,
	      exPrt5    (5) ,
	      exPrt6    (6) ,
	      exPrt7    (7) ,
	      exPrt8    (8) ,
	      exPrt9    (9) ,
	      exPrt10  (10) ,
          exPrt11  (11) ,
          exPrt12  (12) ,

          noConnect (100),

	      inPrt1  (101) ,
	      inPrt2  (102) ,
	      inPrt3  (103) ,
	      inPrt4  (104) ,
	      inPrt5  (105) ,
	      inPrt6  (106) ,
	      inPrt7  (107) ,
	      inPrt8  (108) ,
	      inPrt9  (109) ,
	      inPrt10 (110)	,
		  inPrt11 (111) ,
		  inPrt12 (112)
	      }		   
	For other products see specific values at spec."
      ::= {prtExPh1MlTsEntry 6}

prtExPh1MlTsIConTs OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique time slot  position.
       The valid time slots are 1..24 for T1 Card and
       1..31 for E1 interface. In G732S-E1 lines time slot 16 is not
       valid for data, it is dedicated to multiframe synchronization
       and voice signaling."
      ::= {prtExPh1MlTsEntry 7}

prtExPh1MlTsExt OBJECT-TYPE
        SYNTAX  OBJECT IDENTIFIER
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
             "A pointer to an extension of this table:
              prtExTsSplitTable.
              - If prtExPh1MlTsIConSlot='split', its value
                should be set to the OBJECT IDENTIFIER of the
                prtExTsSplitTable, with its relevant CnfgIdx,
                SltIdx, PrtIdx, TsIdx and 1st TsBit.
              - If prtExPh1MlTsIConSlot is not 'split', its value
                should be set to the OBJECT IDENTIFIER { 0 0 }. "
     ::= { prtExPh1MlTsEntry 8 }

prtExPh1MlTsTest OBJECT-TYPE
      SYNTAX  INTEGER
     {
       none                    (1),
       localLoop               (2),
       remoteLoop              (3),
       remoteBert              (8),	  -- BERT 
       localToneInjection      (9),	  
       remoteToneInjection     (18),  
       localBert               (30),
	   split                   (254),
       notApplicable           (255)
        }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a test to be activated on the selected TS.
	   It is applicable only when prtSTstCmd=testPerTS(31).
	   notApplicable - when prtSTstCmd is NOT testPerTS(31).
	   none  - no test is applied for the selected TS.
       split - when the tests are per Bit of the selected TS."
      ::= { prtExPh1MlTsEntry 9 }

prtExPh1MlTsType OBJECT-TYPE
      SYNTAX  INTEGER
     {
       noConnect               (2),
       data                    (3),
       voice                   (4),
	   cas					   (5),
	   ss7                     (6),
	   transparent             (7),
	   data2                   (8),
       data3                   (9),
	   data4                   (10),
	   ss7n2                   (11),
	   hdlcV2Compatible        (12),
	   subCh1				   (13),
	   subCh2				   (14),
	   subCh3				   (15),
	   subCh4				   (16),
	   subCh5				   (17),
	   subCh6				   (18),
	   subCh7				   (19),
	   subCh8				   (20),
	   trau					   (21),
	   qmux					   (22),
	   dynamic				   (23),
	   signaling			   (24),
	   notApplicable           (255)
        }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The Time Slot Type.

       Transparent - means that the Time Slot will be Rx/Tx as is without processing it.

       If the device requires more than 1 unique data or ss7 Time Slot,
       options with numbers can be used like: data...data4.
       Each numbered Type can go to a different destination.
       ss7n2 - means the 2nd group of ss7 Time Slots.
       data2,data3, data4 mean group 2,3,4 of Data Time Slots.
       subCh1...subCh8 mean Sub Channel 1...8, respectively.
       trau, qmux, dynamic, signaling - are used by GSM devices."      
      ::= { prtExPh1MlTsEntry 10 }

prtExPh1MlTsBundle OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The number of the bundle containing this Time Slot.
       If no bundle exists for this TS or the bundle number
       is irrelevant, the value will be 0."
      ::= { prtExPh1MlTsEntry 11 }


prtExPh1MlTsTestDuration OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
       "This attribute indicates the maximum duration of executing
      a test on the specific TS. This entry applies to all the
      test operations. 

      For the Vmux2100 the values are:
      0 - 60 seconds.

      A zero  value specifies no time limitation.      
      When the test isn't active, the agent initiates this object to
      2 when the duration is needed and to 0 if its not required.
      The user should set this parameter after setting the
      'prtExPh1MlTsTest' parameter."
      ::= { prtExPh1MlTsEntry 12 }

prtExPh1MlTsSubChType OBJECT-TYPE
      SYNTAX  INTEGER
     {
	hdlc			(1),
	transparent		(2),
	notApplicable	(255)
        }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The Time Slot Sub-Channel Type.
	   This variable is relevant only when Time-Slot Type is SubCh
	   (e.g. prtExPh1MlTsType = subCh1...subCh8)."      
      ::= { prtExPh1MlTsEntry 13 }

prtExPh1MlTsSubChMask OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The Sub-Channel Type Mask.
	   This variable is relevant only when Time-Slot Type is SubCh
	   (e.g. prtExPh1MlTsType = subCh1...subCh8)."      
      ::= { prtExPh1MlTsEntry 14 }
	  
prtExPh1MlTsChRate OBJECT-TYPE
      SYNTAX  INTEGER
     	{
		notApplicable	(1),
		r16Kbps			(2),
		r32Kbps			(3),
		r64Kbps			(4),
		r8Kbps			(5),
		auto			(6)	
        }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The Rate of the Signaling Channel.
       notApplicable(1) when TS Type is other than Signaling or Transparent"      
      ::= { prtExPh1MlTsEntry 15 }

prtExPh1MlTsByteReversal OBJECT-TYPE
      SYNTAX  INTEGER
     	{
		notApplicable	(1),
		no				(2),
		yes				(3)
		}
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Byte Reversal.
	   This variable defines whether the LSB or MSB is transmitted first.
	   no(2)	- MSB is transmitted first
	   yes(3)	- LSB is transmitted first."      
      ::= { prtExPh1MlTsEntry 16 }

prtExPh1MlTsSigProfile OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable (1),
--       none          (2),
       p1            (3),
       p2            (4),
       p3            (5),
       p4            (6),
       p5            (7)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the Signaling Profile of the port.
       It is applicable only when prtMl4SigProfile=perTS.
       p1  = profile 1
       p2  = profile 2
       p3  = profile 3
       p4  = profile 4
       p5  = profile 5 "
      ::= { prtExPh1MlTsEntry 17 }

--
-- MPH.1/T1 & MPH.1/E1
-- Internal port objects table
-- (only for the Hybrid modules)
--
prtInPh1MlCnfgTable  OBJECT-TYPE
     SYNTAX SEQUENCE OF PrtInPh1MlCnfgEntry
     MAX-ACCESS not-accessible
     STATUS  current
     DESCRIPTION
      "The write operation into the Table Objects is valid only
       to the TmpCnfg entry."
     ::= {prtPh1MlCnfg 3}

prtInPh1MlCnfgEntry OBJECT-TYPE
      SYNTAX PrtInPh1MlCnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtInPh1MlCnfgIdx, prtInPh1MlSltType, prtInPh1MlPrtIdx }
      ::= { prtInPh1MlCnfgTable 1}

PrtInPh1MlCnfgEntry ::=
      SEQUENCE {
      prtInPh1MlCnfgIdx            Integer32,
      prtInPh1MlSltType            INTEGER,
      prtInPh1MlPrtIdx             Integer32,
      prtInPh1MlConnect            INTEGER,
      prtInPh1MlRate               INTEGER,
      prtInPh1MlProtocol           INTEGER,
      prtInPh1MlConnectionTyp      INTEGER,
      prtInPh1MlCongResponse       INTEGER,
      prtInPh1MlCongLevel          Integer32,
      prtInPh1MlTc                 INTEGER,
      prtInPh1MlFlowControl        INTEGER,
      prtInPh1MlSegment            INTEGER,
      prtInPh1MlFrMngProt          INTEGER,
      prtInPh1MlEnqPeriod          Integer32,
      prtInPh1MlFullRptPeriod      Integer32,
      prtInPh1MlFrWindowSize       Integer32,
      prtInPh1MlErrorsThreshold    Integer32,
      prtInPh1MlMaxIdleTime        Integer32,
	  prtInPh1MlBearerCh           INTEGER,
	  prtInPh1MlAssociatedExCh     INTEGER,
	  prtInPh1MlClockEncoding      INTEGER,
	  prtInPh1MlMinSeparators      Integer32,
	  prtInPh1MlCcittCrc           INTEGER,
	  prtInPh1MlFrameSeparator     INTEGER
      }


prtInPh1MlCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg. "
      ::= { prtInPh1MlCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.

prtInPh1MlSltType OBJECT-TYPE
      SYNTAX  INTEGER
     {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
       notApplicable(255)
     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted.
       For ISDN BRI port of MX300/30:
       io1(5) = isdn1(5) and io2(6) = isdn2(6)
       In the ?004 Unit the entries io6(10)..io12(16) are not valid"
      ::= { prtInPh1MlCnfgEntry 2}

prtInPh1MlPrtIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique port number.
       MPH.1/E1 and MPH.1/T1 cards have three internal interfaces.
       MX3000 modules may have up to 50 internal ports."
      ::= { prtInPh1MlCnfgEntry 3}

prtInPh1MlConnect OBJECT-TYPE
      SYNTAX  INTEGER
       {
  no  (2),
  yes (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the port should be
       considered in any of the mux  algorithms."
      ::= { prtInPh1MlCnfgEntry 4}

prtInPh1MlRate OBJECT-TYPE
      SYNTAX  INTEGER
       {
        r1x56eq56Kbps    (1),
        r1x64eq64Kbps    (2),
        r2x56eq112Kbps   (3),
        r2x64eq128Kbps   (4),
        r3x56eq168Kbps   (5),
        r3x64eq192Kbps   (6),
        r4x56eq224Kbps   (7),
        r4x64eq256Kbps   (8),
        r5x56eq280Kbps   (9),
        r5x64eq320Kbps  (10),
        r6x56eq336Kbps  (11),
        r6x64eq384Kbps  (12),
        r7x56eq392Kbps  (13),
        r7x64eq448Kbps  (14),
        r8x56eq448Kbps  (15),
        r8x64eq512Kbps  (16),
        r9x56eq504Kbps  (17),
        r9x64eq576Kbps  (18),
        r10x56eq560Kbps (19),
        r10x64eq640Kbps (20),
        r11x56eq616Kbps (21),
        r11x64eq704Kbps (22),
        r12x56eq672Kbps (23),
        r12x64eq768Kbps (24),
        r13x56eq728Kbps (25),
        r13x64eq832Kbps (26),
        r14x56eq784Kbps (27),
        r14x64eq896Kbps (28),
        r15x56eq840Kbps (29),
        r15x64eq960Kbps (30),
        r16x56eq896Kbps (31),
        r16x64eq1024Kbps(32),
        r17x56eq952Kbps (33),
        r17x64eq1088Kbps(34),
        r18x56eq1008Kbps(35),
        r18x64eq1152Kbps(36),
        r19x56eq1064Kbps(37),
        r19x64eq1216Kbps(38),
        r20x56eq1120Kbps(39),
        r20x64eq1280Kbps(40),
        r21x56eq1176Kbps(41),
        r21x64eq1344Kbps(42),
        r22x56eq1232Kbps(43),
        r22x64eq1408Kbps(44),
        r23x56eq1288Kbps(45),
        r23x64eq1472Kbps(46),
        r24x56eq1344Kbps(47),
        r24x64eq1536Kbps(48),
        r25x56eq1400Kbps(49),
        r25x64eq1600Kbps(50),
        r26x56eq1456Kbps(51),
        r26x64eq1664Kbps(52),
        r27x56eq1512Kbps(53),
        r27x64eq1728Kbps(54),
        r28x56eq1568Kbps(55),
        r28x64eq1792Kbps(56),
        r29x56eq1624Kbps(57),
        r29x64eq1856Kbps(58),
        r30x56eq1680Kbps(59),
        r30x64eq1920Kbps(60),
        r31x56eq1736Kbps(61),
        r31x64eq1984Kbps(62),
        r32x56eq1792Kbps(63),
        r32x64eq2048Kbps(64),
		r1x1dot5eq1dot5M(65),
		r2x1dot5eq3M    (66),
		r3x1dot5eq4dot5M(67),
		r4x1dot5eq6M    (68),
		r5x1dot5eq7dot5M(69),
		r6x1dot5eq9M    (70),
		r7x1dot5eq10dot5M(71),
		r8x1dot5eq12M   (72),
		r1x2Meq2M       (73),
		r2x2Meq4M       (74),
		r3x2Meq6M       (75),
		r4x2Meq8M       (76),
		r5x2Meq10M      (77),
		r6x2Meq12M      (78),
		r7x2Meq14M      (79),
		r8x2Meq16M      (80),
		noRate         (100)
     }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the port speed. "
      ::= { prtInPh1MlCnfgEntry 5}

prtInPh1MlProtocol OBJECT-TYPE
      SYNTAX  INTEGER
     {
        fr                 (1),
        frPlus             (2),
        pCellRelay         (3),
        hdlcSdlc           (4),
        transparentHdlc    (5),
		ciscoBridgedEth    (6)
     }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the applied protocol."
      ::= { prtInPh1MlCnfgEntry 6}

prtInPh1MlConnectionTyp OBJECT-TYPE
      SYNTAX  INTEGER
     {
	    sameNetManaged  (1),
	    sameNetNotMana  (2),
	    user            (3),
	    otherNet        (4),
	    pubNet          (5),
		notApplicable (255)
     }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the link connection type.
       It is required for three reasons:
     FR/CR Inband management operation (LMI,CLMM...).
     CIR check.
     NMS network management.

       SameNetManaged - indicates network internal line.
       SameNetNotMana - indicates network internal line, but the remote
               mux is not managed by the nms.

       User           - User to Network Interface.
       OtherNet       - Network To Network Interfce.
       PubNet         - Access Mux To PubNet Interface."
      ::= { prtInPh1MlCnfgEntry 7}

prtInPh1MlCongResponse OBJECT-TYPE
      SYNTAX  INTEGER
     {
     no              (2),
        flowControl     (3)
     }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
"This attribute indicates how to handle the congestion indication
 to/from the mux internal connection side (for example
 transmit/receive becn to/from the network).
   no           - do nothing
   FlowControl  - translate the congestion indication between the
                  port and the internal connection port according to
                  the definition of the prtInPh1MlFlowControl
                  parameters. The operation is done in both directions."
      ::= { prtInPh1MlCnfgEntry 8}

prtInPh1MlCongLevel OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the level of delayed data in
       precents of the total available dynamic memory,
       for which the port will start to operate .
       The resolution of the parameter is 5 percent.
	   Valid values: 10..70, 255.
       255=notApplicable."
      ::= { prtInPh1MlCnfgEntry 9}

prtInPh1MlTc OBJECT-TYPE
      SYNTAX  INTEGER
          {
          tc1sec  (1),
          tc2sec  (2),
          tc3sec  (3),
          tc4sec  (4),
		  notApplicable (255)
          }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Tc parameter which is the time
       period of the sliding window in which the Bc/Be are tested.
       The value of this parameter is identical for all the ports in the
       specific card.
       255=notApplicable."
      ::= { prtInPh1MlCnfgEntry 10}

prtInPh1MlFlowControl OBJECT-TYPE
      SYNTAX  INTEGER
     {
        none                (2),
        fecnBecn            (3)
     }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the required flow control betweeen
       the port and the remote equipment."
      ::= { prtInPh1MlCnfgEntry 11}

prtInPh1MlSegment OBJECT-TYPE
      SYNTAX  INTEGER
   {
   notApplicable (1),
   s36Byte       (2),
   s150Byte      (3),
   s264Byte      (4),
   s378Byte      (5),
   s492Byte      (6),
   s236Byte      (7),
   s472Byte      (8),
   s708Byte      (9),
   s944Byte     (10),
   s1180Byte    (11)
   }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object is the Segmentation in Bytes.
	   In protocol FR+, ISDN internals, MX 30/300 the segmentation is:

       50 (2) ,158 (3) ,266 (4) ,376 (5), 484 (6)

       In  MX 3000/4:
       For protocol FR+ (internal ISDN ports of MHS.S, MHS.U, MHS.E1, MHS.T1
       cards) segmentation values are:

       236 (7),472 (8), 708 (9), 944 (10) ,1180 (11)"

    ::= { prtInPh1MlCnfgEntry 12}

prtInPh1MlFrMngProt OBJECT-TYPE
      SYNTAX  INTEGER
   {
   notApplicable (1),
   none          (2),
   lmi           (3),
   ansiT1        (4), --Annex D
   annexA        (5)
   }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the Frame-Relay management protocol.
       ansiT1 = ANSI T1.617 Annex D (this is the default value).
       This parameter is applicable only for FR and FR+ protocols.
       When prtInPh1MlConnectionTyp = sameNetManaged, this object
       will be RO (internally determined). "
      ::= { prtInPh1MlCnfgEntry 13}

prtInPh1MlEnqPeriod OBJECT-TYPE
      SYNTAX  Integer32 (0..30)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object is the Status Enquiry Period, in seconds.
       It determines the frequency of the Status Enquiry message
       as sent by the FR user side.
       At the FR network side, it determines the timeout for this
       message reception.
    Default = 4 seconds.
       This parameter is applicable only for FR and FR+ protocols
    AND
       only when prtInPh1MlFrMngProt is NOT (notApplicable or none).
       0=notApplicable."
    ::= { prtInPh1MlCnfgEntry 14}

prtInPh1MlFullRptPeriod OBJECT-TYPE
      SYNTAX  Integer32 (0..255)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object is the Full Report Frequency.
       It determines the number of the Status Enquiry messages
       sent by the FR user side, before a Full Report Request is
       sent.
       The units are : Status Enquiry messages (periods).
    Valid values: 1 .. 255.
       255 = infinite (never sent).
       This parameter is applicable only for FR and FR+ protocols
    AND
       only when prtInPh1MlFrMngProt is NOT (notApplicable or none).
       0=notApplicable."
    ::= { prtInPh1MlCnfgEntry 15}

prtInPh1MlFrWindowSize OBJECT-TYPE
      SYNTAX  Integer32 (0..10)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object is the FR Window Size.
       It determines the number of samplings in the sliding window
       that counts the errors.
       This parameter is applicable only for FR and FR+ protocols
    AND
       only when prtInPh1MlFrMngProt is NOT (notApplicable or none).
       0=notApplicable."
    ::= { prtInPh1MlCnfgEntry 16}

prtInPh1MlErrorsThreshold OBJECT-TYPE
      SYNTAX  Integer32 (0..10)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object is the Max Errors.
       It determines the number of Status Enquiry Errors that
       occured within the FR sliding window, before this port is
       considered DOWN (threshold).
       This parameter is applicable only for FR and FR+ protocols
    AND
       only when prtInPh1MlFrMngProt is NOT (notApplicable or none).
       0=notApplicable. "
    ::= { prtInPh1MlCnfgEntry 17}

prtInPh1MlMaxIdleTime OBJECT-TYPE
     SYNTAX  Integer32 (0..1800)
     MAX-ACCESS   read-write
     STATUS   current
     DESCRIPTION
     "Move to higher prioritized connected link	after this period of
      seconds of silence on the current link.
	  0=Never. Never move to higher prioritized connected link.
      UNIT is seconds.
      Valid values are: 0, 1, 2, 3, 4, 5, 10, 20, 30, 40, 50, 60, 120, 180, 240, 300,
      360, 420, 480, 540, 600, 900, 1200, 1500, 1800.
      Attempt to Set an invalid value will result in getting the default value."
     DEFVAL { 10 }
     ::= {prtInPh1MlCnfgEntry 18}

prtInPh1MlBearerCh OBJECT-TYPE
     SYNTAX  INTEGER
	 {
      notApplicable (1),
      channelB1     (3),
      channelB2     (4),
	  chB1andchB2   (5),
	  none          (255)
	       }
	 MAX-ACCESS   read-write
     STATUS   current
     DESCRIPTION
	 "Defines which B (bearer) channels are used for transferring ISDN data.
	  Default value is: none (255).
	  anyChannel (2) is skipped because it is not in use here."
	 ::= {prtInPh1MlCnfgEntry 19}

prtInPh1MlAssociatedExCh OBJECT-TYPE
      SYNTAX  INTEGER
     {
        exPrt1        (1),
        exPrt2        (2),
		exPrt3        (3),
		exPrt4        (4),
		notApplicable (255)
     }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the external port associated to this internal
       port. At present, it is used by the Hybrid (mp2100h), MHS-4 cards which
       can have up to 64 dynamic internal ports associated with External ports.

       For ISDN cards, the value will be: notApplicable (255).
       The associated external of an ISDN internal port is represented
       by the MIB object: prtIsdnDirectoryPrtNu."
      ::= { prtInPh1MlCnfgEntry 20}

prtInPh1MlClockEncoding OBJECT-TYPE
      SYNTAX  INTEGER
	  {
	  notApplicable (1),
	  nrz           (2),
	  nrzI          (3),
	  fm0           (4),
	  manchester    (5),
	  diffManchester(6)
	  }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object is the Encoding type of the Line.
       This parameter is applicable only for FR and FR+ protocols."
	   ::= { prtInPh1MlCnfgEntry 21}

prtInPh1MlMinSeparators OBJECT-TYPE
      SYNTAX  Integer32 (0..16)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Minimum number of bytes separating between two adjacent frames (HDLC item).
       0 = notApplicable"
	   ::= { prtInPh1MlCnfgEntry 22}

prtInPh1MlCcittCrc OBJECT-TYPE
      SYNTAX  INTEGER
	  {
	  notApplicable (1),
	  crc16         (2),
	  crc32         (3)
	  }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates how many Bits are used for CRC (HDLC item)."
	   ::= { prtInPh1MlCnfgEntry 23}

prtInPh1MlFrameSeparator OBJECT-TYPE
      SYNTAX  INTEGER
	  {
	  notApplicable (1),
	  idles         (2),
	  flags         (3)
	  }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates what should be transferred on the line when there
       are no frames to pass (HDLC item).
       idles: mean that FF will pass on the line
       flags: mean that 7E will pass on the line."
	   ::= { prtInPh1MlCnfgEntry 24}


--
-- MPH1.T1 & MPH1.E1
-- Internal port Dlci objects table
--

prtInPh1MlDlciTable  OBJECT-TYPE
     SYNTAX SEQUENCE OF PrtInPh1MlDlciEntry
     MAX-ACCESS not-accessible
     STATUS  current
     DESCRIPTION
      "The write operation into the Table Objects is valid only
       to the TmpCnfg entry."
     ::= {prtPh1MlCnfg 4}

prtInPh1MlDlciEntry OBJECT-TYPE
      SYNTAX PrtInPh1MlDlciEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtInPh1MlDlciCnfgIdx, prtInPh1MlDlciSltIdx, prtInPh1MlDlciPrtIdx, prtInPh1MlDlciIdx }
      ::= { prtInPh1MlDlciTable 1}

PrtInPh1MlDlciEntry ::=
      SEQUENCE {
      prtInPh1MlDlciCnfgIdx        Integer32,
      prtInPh1MlDlciSltIdx         INTEGER,
      prtInPh1MlDlciPrtIdx         INTEGER,
      prtInPh1MlDlciIdx            Integer32,

      prtInPh1MlDlciValid          INTEGER,
      prtInPh1MlDlciIConSlt        INTEGER,
      prtInPh1MlDlciIConPrt        INTEGER,
      prtInPh1MlDlciIConDlci       Integer32,

      prtInPh1MlDlciTxBc           INTEGER,
      prtInPh1MlDlciTxBe           INTEGER,
      prtInPh1MlDlciRxBc           INTEGER,
      prtInPh1MlDlciRxBe           INTEGER,

      prtInPh1MlDlciPriority       Integer32,

      prtInPh1MlDlciStatus         INTEGER
      }


prtInPh1MlDlciCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg. "
      ::= { prtInPh1MlDlciEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.

prtInPh1MlDlciSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
     {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted.
       In the ?004 Unit the entries io6(10)..io16) are not valid"
      ::= { prtInPh1MlDlciEntry 2}

prtInPh1MlDlciPrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
 {
       inPrt1  (101) ,
       inPrt2  (102) ,
       inPrt3  (103)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique internal port number.
       MPH.1/E1 and MPH.1/T1 cards have three internal ports."
      ::= { prtInPh1MlDlciEntry 3}

prtInPh1MlDlciIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..991)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique index for each possible
       used dlci(16..991). When the protocol is not Multiplexing
       protocol, then its type is 'user' and the only valid index
       is 1."
      ::= { prtInPh1MlDlciEntry 4}

prtInPh1MlDlciValid OBJECT-TYPE
      SYNTAX  INTEGER
     {
     no  (2),
     yes (3)
     }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the attributes in this entry
       are valid or not. The user can add/delete pvc (dlci to dlci
       connection) by modifing this object"
      ::= { prtInPh1MlDlciEntry 5}

prtInPh1MlDlciIConSlt OBJECT-TYPE
      SYNTAX  INTEGER
 {
          noConnect(2),
    cl    (3),
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique slot position In the Mux
       (Agent) where the dlci is routed to.
       In the ?004 Unit the entries io6(10)..io16) are not valid"
      ::= { prtInPh1MlDlciEntry 6}

prtInPh1MlDlciIConPrt OBJECT-TYPE
      SYNTAX  INTEGER
      {
       exPrt1    (1) ,
       exPrt2    (2) ,
       exPrt3    (3) ,
       exPrt4    (4) ,
       exPrt5    (5) ,
       exPrt6    (6) ,
       exPrt7    (7) ,
       exPrt8    (8) ,
       exPrt9    (9) ,
       exPrt10  (10) ,
    clNMS    (99) ,
          noConnect (100),
       inPrt1  (101) ,
       inPrt2  (102) ,
       inPrt3  (103) ,
       inPrt4  (104) ,
       inPrt5  (105) ,
       inPrt6  (106) ,
       inPrt7  (107) ,
       inPrt8  (108) ,
       inPrt9  (109) ,
       inPrt10 (110) ,
    inPrt11 (111) ,
    inPrt12 (112)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique port id which the dlci is
       routed to."
      ::= { prtInPh1MlDlciEntry 7}


prtInPh1MlDlciIConDlci OBJECT-TYPE
      SYNTAX  Integer32    (1..991)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique internal connection dlci
       number which the src dlci is routed to."
      ::= { prtInPh1MlDlciEntry 8}

prtInPh1MlDlciTxBc OBJECT-TYPE
      SYNTAX  INTEGER
        {
         full       (1),
         zero       (2),
         txBc9600bps    (3),
        txBc14200bps    (4),
        txBc19200bps    (5),
        txBc28800bps    (6),
        txBc32000bps    (7),
        txBc38400bps    (8),
        txBc48000bps    (9),
        txBc56000bps   (10),
        txBc57600bps   (11),
          txBc64Kbps   (12),
         txBc128Kbps   (13),
         txBc192Kbps   (14),
         txBc256Kbps   (15),
         txBc320Kbps   (16),
         txBc384Kbps   (17),
         txBc448Kbps   (18),
         txBc512Kbps   (19),
         txBc768Kbps   (20),
        txBc1024Kbps   (21)
        }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique Tx committed bandwidth on
       the user transmit line or at the port receive line."
      ::= { prtInPh1MlDlciEntry 9}


prtInPh1MlDlciTxBe OBJECT-TYPE
      SYNTAX  INTEGER
        {
         full       (1),
         zero       (2),
         txBe9600bps    (3),
        txBe14200bps    (4),
        txBe19200bps    (5),
        txBe28800bps    (6),
        txBe32000bps    (7),
        txBe38400bps    (8),
        txBe48000bps    (9),
        txBe56000bps   (10),
        txBe57600bps   (11),
          txBe64Kbps   (12),
         txBe128Kbps   (13),
         txBe192Kbps   (14),
         txBe256Kbps   (15),
         txBe320Kbps   (16),
         txBe384Kbps   (17),
         txBe448Kbps   (18),
         txBe512Kbps   (19),
         txBe768Kbps   (20),
        txBe1024Kbps   (21)
        }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique Tx excess bandwidth on the
      user transmit line or at the port receive line."
      ::= { prtInPh1MlDlciEntry 10}


prtInPh1MlDlciRxBc OBJECT-TYPE
      SYNTAX  INTEGER
        {
         full       (1),
         zero       (2),
         rxBc9600bps    (3),
        rxBc14200bps    (4),
        rxBc19200bps    (5),
        rxBc28800bps    (6),
        rxBc32000bps    (7),
        rxBc38400bps    (8),
        rxBc48000bps    (9),
        rxBc56000bps   (10),
        rxBc57600bps   (11),
          rxBc64Kbps   (12),
         rxBc128Kbps   (13),
         rxBc192Kbps   (14),
         rxBc256Kbps   (15),
         rxBc320Kbps   (16),
         rxBc384Kbps   (17),
         rxBc448Kbps   (18),
         rxBc512Kbps   (19),
         rxBc768Kbps   (20),
        rxBc1024Kbps   (21)
        }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique Rx committed bandwidth on
       the user receive line or at the port transmit line."
      ::= { prtInPh1MlDlciEntry 11}


prtInPh1MlDlciRxBe OBJECT-TYPE
      SYNTAX  INTEGER
        {
         full       (1),
         zero       (2),
         rxBe9600bps    (3),
        rxBe14200bps    (4),
        rxBe19200bps    (5),
        rxBe28800bps    (6),
        rxBe32000bps    (7),
        rxBe38400bps    (8),
        rxBe48000bps    (9),
        rxBe56000bps   (10),
        rxBe57600bps   (11),
          rxBe64Kbps   (12),
         rxBe128Kbps   (13),
         rxBe192Kbps   (14),
         rxBe256Kbps   (15),
         rxBe320Kbps   (16),
         rxBe384Kbps   (17),
         rxBe448Kbps   (18),
         rxBe512Kbps   (19),
         rxBe768Kbps   (20),
        rxBe1024Kbps   (21)
        }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique Rx excess bandwidth on the
      user receive line or at the port transmit line."
      ::= { prtInPh1MlDlciEntry 12}


prtInPh1MlDlciPriority OBJECT-TYPE
      SYNTAX  Integer32  (1..8)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique priority of the pcv.
       1 is the lowest priority and 8 is the highest priority."
      ::= { prtInPh1MlDlciEntry 13}



prtInPh1MlDlciStatus OBJECT-TYPE
      SYNTAX  INTEGER
 {
          disconnected (1),
          connected    (2)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the status of the pvc. The status is
       disconnected(1) when one of the sides is programmed as
       not connected"
      ::= { prtInPh1MlDlciEntry 14}


--
-- ML-20 - High Speed Main Link card
-- External Port Objects
--
prtPhMlCnfgTable  OBJECT-TYPE
     SYNTAX SEQUENCE OF PrtPhMlCnfgEntry
     MAX-ACCESS not-accessible
     STATUS  current
     DESCRIPTION
      "The write operation into the Table Objects is valid only
       to the TmpCnfg entry."
     ::= {prtPh1MlCnfg 5}

prtPhMlCnfgEntry OBJECT-TYPE
      SYNTAX PrtPhMlCnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtPhMlCnfgIdx, prtPhMlSltIdx, prtPhMlPrtIdx }
      ::= { prtPhMlCnfgTable 1}

PrtPhMlCnfgEntry ::=
      SEQUENCE {
      prtPhMlCnfgIdx        Integer32,
      prtPhMlSltIdx         INTEGER,
      prtPhMlPrtIdx         INTEGER,
      prtPhMlConnect        INTEGER,
      prtPhMlRate           INTEGER,
      prtPhMlCAS            INTEGER,
      prtPhMlClockMode      INTEGER,
      prtPhMlSatBuffer      INTEGER,
      prtPhMlDialProcess    INTEGER,
      prtPhMlSyncRestore    Integer32,
      prtPhMlBus            INTEGER,
      prtPhMlMfSyncSlot     INTEGER,
	  prtPhMlClockSource    INTEGER,
	  prtPhMlErrCorrection  INTEGER,
	  prtPhMlCorrectionMode INTEGER,
	  prtPhMlControlSignals INTEGER,
	  prtPhMlInterfaceType  INTEGER,
	  prtPhMlClockPolarity 	INTEGER
      }


prtPhMlCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg. "
      ::= { prtPhMlCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.

prtPhMlSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
     {
       notApplicable (1),
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the module is inserted.
       In the ?004 Unit the entries io6(10)..io12(16) are not valid.
       
       For the Vmux2100 Main Board notApplicable (1) is used."
      ::= { prtPhMlCnfgEntry 2}

prtPhMlPrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
       {
       exPrt1    (1)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  port number.
       ML-20 cards have just one external interface."
      ::= { prtPhMlCnfgEntry 3}

prtPhMlConnect OBJECT-TYPE
      SYNTAX  INTEGER
       {
  no  (2),
  yes (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the port should be considered
       in any of the mux  algorithms."
      ::= {prtPhMlCnfgEntry 4}

prtPhMlRate     OBJECT-TYPE
      SYNTAX  INTEGER
       {
        r1x64eq64Kbps    (2),
        r2x64eq128Kbps   (4),
        r3x64eq192Kbps   (6),
        r4x64eq256Kbps   (8),
        r5x64eq320Kbps  (10),
        r6x64eq384Kbps  (12),
        r7x64eq448Kbps  (14),
        r8x64eq512Kbps  (16),
        r9x64eq576Kbps  (18),
        r10x64eq640Kbps (20),
        r11x64eq704Kbps (22),
        r12x64eq768Kbps (24),
        r13x64eq832Kbps (26),
        r14x64eq896Kbps (28),
        r15x64eq960Kbps (30),
        r16x64eq1024Kbps(32),
        r17x64eq1088Kbps(34),
        r18x64eq1152Kbps(36),
        r19x64eq1216Kbps(38),
        r20x64eq1280Kbps(40),
        r21x64eq1344Kbps(42),
        r22x64eq1408Kbps(44),
        r23x64eq1472Kbps(46),
        r24x64eq1536Kbps(48),
        r25x64eq1600Kbps(50),
        r26x64eq1664Kbps(52),
        r27x64eq1728Kbps(54),
        r28x64eq1792Kbps(56),
        r29x64eq1856Kbps(58),
        r30x64eq1920Kbps(60),
        r31x64eq1984Kbps(62),
        r32x64eq2048Kbps(64),		
		auto            (70)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the configured port speed.
       auto - rate is adapted automatically to the attached modem rate."
      ::= {prtPhMlCnfgEntry 5}

prtPhMlCAS OBJECT-TYPE
      SYNTAX  INTEGER
       {
  no  (2),
  yes (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether Channel Associated
       Signaling (CAS) is used."
      ::= {prtPhMlCnfgEntry 6}

prtPhMlClockMode OBJECT-TYPE
      SYNTAX  INTEGER
       {
          dce     (2),
          ext-dce (3),
          dte     (4)
          }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Clock mode."
      ::= { prtPhMlCnfgEntry 7}

prtPhMlSatBuffer OBJECT-TYPE
      SYNTAX  INTEGER
       {
  notApplicable (1),
  no  (2),
  yes (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Satellite Buffer (+/- 256)."
      ::= {prtPhMlCnfgEntry 8}

prtPhMlDialProcess OBJECT-TYPE
      SYNTAX  INTEGER
       {
  notApplicable (1),
  no            (2),
  callIn        (3),
  callOut       (4)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Dial Process."
      ::= {prtPhMlCnfgEntry 9}

prtPhMlSyncRestore OBJECT-TYPE
      SYNTAX  Integer32 (0..10)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Sync Restoration time, in seconds.
       notApplicable=0. "
      ::= {prtPhMlCnfgEntry 10}

prtPhMlBus OBJECT-TYPE
      SYNTAX  INTEGER
       {
  none (1),
  busA (2),
  busB (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The TDM BUS this port is linked to."
      ::= {prtPhMlCnfgEntry 11}

prtPhMlMfSyncSlot  OBJECT-TYPE
      SYNTAX  INTEGER
       {
          none  (2),
          io1   (5),
          io2   (6),
          io3   (7),
          io4   (8),
          io5   (9),
          io6  (10),
          io7  (11),
          io8  (12),
          io9  (13),
          io10 (14),
          io11 (15),
          io12 (16)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the sync is synchronized
       according to a certain card and the slot of this card.
       This operation is required in order to bypass signaling of
       PCM voice channels.
       In the ?004 Unit the entries io6(10)..io12(16) are not valid"
      ::= {prtPhMlCnfgEntry 12}

prtPhMlClockSource OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable (1),
       txClock       (2),
       rxClock       (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The Clock Source: TC (Tx Clock) or RC (Rx Clock) signals."
      ::= {prtPhMlCnfgEntry 13}

prtPhMlErrCorrection OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable (1),
       no            (2),
       yes           (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates if Error Correction mechanism should be applied or not.
       It will be applicable only if the interface HW includes the Error Correction 
       chip."
      ::= {prtPhMlCnfgEntry 14}

prtPhMlCorrectionMode OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable (1),
       random        (2),
       bursty        (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object is applicable only when prtPhMlErrCorrection=yes.
       random - enables to correct up to 3 random errors in an 23 bit frame
                built from 12 data bits and 11 appended parity bits.
       bursty - interleaving 3 frames, allows correcting bursts of 9 bit length."
      ::= {prtPhMlCnfgEntry 15}

   
prtPhMlControlSignals OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable (1),
       ignore        (2),
       implement     (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object shows whether the Port will ignore or implement the control signals
       like DCD, CTS, DTR."
      ::= {prtPhMlCnfgEntry 16}

prtPhMlInterfaceType OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable (1),
       v35           (2),
       x21           (3), -- v.11
       rs232         (4),  -- v.28
       rs449         (5),
       ei530         (6),
       ei530a        (7)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The SW Configurable Interface Type."
      ::= {prtPhMlCnfgEntry 17}

prtPhMlClockPolarity  OBJECT-TYPE     
	 SYNTAX  INTEGER
       {
       notApplicable   (1),
       normal          (2),
       inverted        (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the clock polarity."
      ::= {prtPhMlCnfgEntry 18}

-- This table is an extension for new version of MAXcess
-- modules.
prtLogicalCnfgTable  OBJECT-TYPE
     SYNTAX SEQUENCE OF PrtLogicalCnfgEntry
     MAX-ACCESS not-accessible
     STATUS  current
     DESCRIPTION
      "The write operation into the Table Objects is valid only
       to the TmpCnfg entry."
     ::= {prtLogicalCnfg 1}

prtLogicalCnfgEntry OBJECT-TYPE
      SYNTAX PrtLogicalCnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtLogicalCnfgIdx, prtLogicalSltIdx, prtLogicalPrtIdx }
      ::= { prtLogicalCnfgTable 1}

PrtLogicalCnfgEntry ::=
      SEQUENCE {
      prtLogicalCnfgIdx   Integer32,
      prtLogicalSltIdx    INTEGER,
      prtLogicalPrtIdx   Integer32,
      prtLogicalConnect    INTEGER,
      prtLogicalFunction        INTEGER,
      prtLogicalRowStatus      RowStatus
}

prtLogicalCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg. "
      ::= { prtLogicalCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.

prtLogicalSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
            {
              io1   (5),
              io2   (6),
              io3   (7),
              io4   (8),
              io5   (9),
              io6  (10),
              io7  (11),
              io8  (12),
              io9  (13),
              io10 (14),
              io11 (15),
              io12 (16),
       notApplicable(255)
            }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
        "Slot Index.
         For ISDN BRI Ports of MX300/30,
    io1(5) = isdn1(5) and io2(6) = isdn2(6)."
      ::= { prtLogicalCnfgEntry 2}

prtLogicalPrtIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  port number.
       This port number should be an internal port number:
        inPrt1(101)->inPrt50(150), linkSel1(200)->linkSel50(250),
        encaps1(300)-> encaps50(350), huntGr1(101) -> huntGr10(110)."
      ::= { prtLogicalCnfgEntry 3}

prtLogicalConnect OBJECT-TYPE
      SYNTAX  INTEGER
              {
                no  (2),
             yes (3)
              }
      MAX-ACCESS  read-create
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the port should be considered
       in any of the mux  algorithms."
      ::= { prtLogicalCnfgEntry 4}

prtLogicalFunction  OBJECT-TYPE
      SYNTAX  INTEGER
              {
                notApplicable(1),
                linkSelector(2),
         encapsulator(3),
   huntGroup(4)
              }
     MAX-ACCESS   read-create
     STATUS   current
     DESCRIPTION
     "This parameter defines the function of the relevant channel."
     ::= { prtLogicalCnfgEntry 5 }

prtLogicalRowStatus  OBJECT-TYPE
     SYNTAX  RowStatus
     MAX-ACCESS   read-create
     STATUS   current
     DESCRIPTION
     "This parameter allows the NMS to create/delete logical ports.
      The only possible supported RowStatus vaules are
      active (1) and destroy (6)."
     ::= { prtLogicalCnfgEntry 6 }


-- This group contains management information for the
-- link selector function.

linkSelectorCnfgTable  OBJECT-TYPE
     SYNTAX SEQUENCE OF LinkSelectorCnfgEntry
     MAX-ACCESS not-accessible
     STATUS  current
     DESCRIPTION
      "The write operation into the Table Objects is valid only
       to the TmpCnfg entry."
     ::= { prtLogicalCnfg 2}

linkSelectorCnfgEntry OBJECT-TYPE
      SYNTAX LinkSelectorCnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {linkSelectorCnfgIdx, linkSelectorSltIdx, linkSelectorPrtIdx }
      ::= { linkSelectorCnfgTable 1}

LinkSelectorCnfgEntry ::=
      SEQUENCE {
      linkSelectorCnfgIdx      Integer32,
      linkSelectorSltIdx         INTEGER,
      linkSelectorPrtIdx         Integer32,
      linkSelectorMaxIdleTime      Integer32,
      linkSelectorMode INTEGER,
      linkSelectorRevert INTEGER,
      linkSelectorMinBUSession      Integer32 
	}

linkSelectorCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of
      the Cnfg (1..100) being accessed.
       Idx 255 relates to the TmpCnfg. "
      ::= { linkSelectorCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.

linkSelectorSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
            {
              io1   (5),
              io2   (6),
              io3   (7),
              io4   (8),
              io5   (9),
              io6  (10),
              io7  (11),
              io8  (12),
              io9  (13),
              io10 (14),
              io11 (15),
              io12 (16),
       notApplicable(255)
            }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
        "Slot Index"
      ::= { linkSelectorCnfgEntry 2}

linkSelectorPrtIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  port number.
       This port number should be internal port number:
       higher or equal to linkSeL1(201)."
      ::= { linkSelectorCnfgEntry 3}

linkSelectorMaxIdleTime OBJECT-TYPE
     SYNTAX  Integer32 (0..255)
     MAX-ACCESS   read-write
     STATUS   current
     DESCRIPTION
     "Move to higher prioritized connected link
     after this period of seconds of silence on the current link.
     0=move immediately to higher prioritized connected link.
     UNIT is seconds."
     DEFVAL { 0 }
::= {linkSelectorCnfgEntry 4}

linkSelectorMode OBJECT-TYPE
      SYNTAX  INTEGER { notApplicable(1),
    backup(2), bod(3)       }
      MAX-ACCESS   read-write
     STATUS   current
     DESCRIPTION
     " If the link selector is in mode:
      backup(2)=then the link with the lower priority will be
                used in case of failure of the higher priority link,
      bod(3)=bandwidth on demand or dynamic bandwidth allocation
             means that links with lower priority will be used
             whenever additional bandwidth is required. "
     DEFVAL { backup }
::= {linkSelectorCnfgEntry 5}

linkSelectorRevert OBJECT-TYPE
      SYNTAX  INTEGER { notApplicable(1),
   auto(2), manual(3)       }
      MAX-ACCESS   read-write
     STATUS   current
     DESCRIPTION
     " If the link selector is in mode backup:
      auto(2)=return automatically to Main link when it is OK.
      manual(3)=stays connected to backup link."
     DEFVAL { auto }
::= {linkSelectorCnfgEntry 6}

linkSelectorMinBUSession     OBJECT-TYPE
     SYNTAX  Integer32 (1..255)
     MAX-ACCESS   read-write
     STATUS   current
     DESCRIPTION
     "Minimum duration of a backup session before
     returning to Main Link. Relevant in Backup Mode and
     when Revert is auto(2).  Value 255 is for NEVER which
     means never return to Main Link.
     UNIT is minutes."
     DEFVAL { 10 }
::= {linkSelectorCnfgEntry 7}

-- Prioritized Links
linkSelectorPLinkTable  OBJECT-TYPE
     SYNTAX SEQUENCE OF LinkSelectorPLinkEntry
     MAX-ACCESS not-accessible
     STATUS  current
     DESCRIPTION
      "The write operation into the Table Objects is valid only
       to the TmpCnfg entry."
     ::= { prtLogicalCnfg 3}

linkSelectorPLinkEntry OBJECT-TYPE
      SYNTAX LinkSelectorPLinkEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {pLinkCnfgIdx, pLinkSltIdx, pLinkPrtIdx, pLinkIdx }
      ::= { linkSelectorPLinkTable 1}

LinkSelectorPLinkEntry ::=
      SEQUENCE {
      pLinkCnfgIdx      Integer32,
      pLinkSltIdx   INTEGER,
      pLinkPrtIdx       Integer32,
      pLinkIdx         Integer32,
      pLinkSlotNu       INTEGER,
      pLinkPortNu       Integer32,
      pLinkPrioNu       Integer32,
      pLinkVRate        INTEGER
}

pLinkCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
     "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg. "
      ::= { linkSelectorPLinkEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.

pLinkSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
            {
              io1   (5),
              io2   (6),
              io3   (7),
              io4   (8),
              io5   (9),
              io6  (10),
              io7  (11),
              io8  (12),
              io9  (13),
              io10 (14),
              io11 (15),
              io12 (16),
       notApplicable(255)
            }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
        "Slot Index"
      ::= { linkSelectorPLinkEntry 2}

pLinkPrtIdx OBJECT-TYPE
      SYNTAX  Integer32(200..250)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  port number.
       This port number should be the link selector number."
::= { linkSelectorPLinkEntry 3}


pLinkIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..8)
      MAX-ACCESS   read-only
     STATUS   current
     DESCRIPTION
     "This index is the row number."
::= { linkSelectorPLinkEntry 4}

pLinkSlotNu OBJECT-TYPE
      SYNTAX  INTEGER {
      noConnect (2), cl(3),
        io1(5),
        io2(6),
        io3(7),
        io4(8),
        io5(9),
        io6(10),
        io7(11),
        io8(12),
        io9(13),
        io10(14),
        io11(15),
        io12(16),
        notApplicable(255)
       }
     MAX-ACCESS   read-write
     STATUS   current
     DESCRIPTION
     "The slot of the prioritized link.
     For ISDN BRI ports of MX300/30,
 io1(5) = isdn1(5) and io2(6) = isdn2(6)."
     DEFVAL { noConnect }
::= { linkSelectorPLinkEntry 5 }

pLinkPortNu OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS   read-write
      STATUS   current
      DESCRIPTION
      "The port of the prioritized link.
      Value 100 is for noConnect."
      DEFVAL { 100 }
::= { linkSelectorPLinkEntry 6 }

pLinkPrioNu OBJECT-TYPE
      SYNTAX  Integer32(1..8)
      MAX-ACCESS   read-write
      STATUS   current
      DESCRIPTION
      "The priority of the prioritized link.
       MIN=1...., MAX=8."
::= { linkSelectorPLinkEntry 7 }

pLinkVRate OBJECT-TYPE
       SYNTAX INTEGER {
        r1x56eq56Kbps    (1),
        r1x64eq64Kbps    (2),
        r2x56eq112Kbps   (3),
        r2x64eq128Kbps   (4),
        r3x56eq168Kbps   (5),
        r3x64eq192Kbps   (6),
        r4x56eq224Kbps   (7),
        r4x64eq256Kbps   (8),
        r5x56eq280Kbps   (9),
        r5x64eq320Kbps  (10),
        r6x56eq336Kbps  (11),
        r6x64eq384Kbps  (12),
        r7x56eq392Kbps  (13),
        r7x64eq448Kbps  (14),
        r8x56eq448Kbps  (15),
        r8x64eq512Kbps  (16),
        r9x56eq504Kbps  (17),
        r9x64eq576Kbps  (18),
        r10x56eq560Kbps (19),
        r10x64eq640Kbps (20),
        r11x56eq616Kbps (21),
        r11x64eq704Kbps (22),
        r12x56eq672Kbps (23),
        r12x64eq768Kbps (24),
        r13x56eq728Kbps (25),
        r13x64eq832Kbps (26),
        r14x56eq784Kbps (27),
        r14x64eq896Kbps (28),
        r15x56eq840Kbps (29),
        r15x64eq960Kbps (30),
        r16x56eq896Kbps (31),
        r16x64eq1024Kbps(32),
        r17x56eq952Kbps (33),
        r17x64eq1088Kbps(34),
        r18x56eq1008Kbps(35),
        r18x64eq1152Kbps(36),
        r19x56eq1064Kbps(37),
        r19x64eq1216Kbps(38),
        r20x56eq1120Kbps(39),
        r20x64eq1280Kbps(40),
        r21x56eq1176Kbps(41),
        r21x64eq1344Kbps(42),
        r22x56eq1232Kbps(43),
        r22x64eq1408Kbps(44),
        r23x56eq1288Kbps(45),
        r23x64eq1472Kbps(46),
        r24x56eq1344Kbps(47),
        r24x64eq1536Kbps(48),
        r25x56eq1400Kbps(49),
        r25x64eq1600Kbps(50),
        r26x56eq1456Kbps(51),
        r26x64eq1664Kbps(52),
        r27x56eq1512Kbps(53),
        r27x64eq1728Kbps(54),
        r28x56eq1568Kbps(55),
        r28x64eq1792Kbps(56),
        r29x56eq1624Kbps(57),
        r29x64eq1856Kbps(58),
        r30x56eq1680Kbps(59),
        r30x64eq1920Kbps(60),
        r31x56eq1736Kbps(61),
        r31x64eq1984Kbps(62),
        noRate(100)
       }
       MAX-ACCESS   read-write
       STATUS   current
       DESCRIPTION
     "The rate to use with this link."
       DEFVAL { noRate }
::= { linkSelectorPLinkEntry 8 }


--
-- Megaplex or Kilomux ?000/?004 MPH.1/3 High speed packet data cards.
-- Megaplex or Kilomux ?000/?004 MPL.6 Low speed packet data cards.
--      (Mph1, Mph3, Mpl6)
-- Maxcess 3000/3004 MLS-3/6, MHS-1/3
--
-- prtExPhPlCnfgTable  OBJECT IDENTIFIER ::= {prtPhPlCnfg 1}
-- prtExPhPlDlciTable  OBJECT IDENTIFIER ::= {prtPhPlCnfg 2}
-- prtExPhPlModemTable OBJECT IDENTIFIER ::= {prtPhPlCnfg 3}

-- Mph.1 Mph.3 Mpl.6/ Kphs.1 Kphs.3 Mls.3 Mls.6 Mhs.1 Mhs.3
-- External port objects table

prtExPhPlCnfgTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtExPhPlCnfgEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION "The write operation into the Table Objects is
      valid only to the TmpCnfg entry."
      ::= {prtPhPlCnfg 1}

prtExPhPlCnfgEntry OBJECT-TYPE
      SYNTAX PrtExPhPlCnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtExPhPlCnfgIdx, prtExPhPlSltIdx, prtExPhPlPrtIdx}
      ::= { prtExPhPlCnfgTable 1}

PrtExPhPlCnfgEntry ::=
      SEQUENCE {
      prtExPhPlCnfgIdx            Integer32,
      prtExPhPlSltIdx             INTEGER,
      prtExPhPlPrtIdx             INTEGER,
      prtExPhPlConnect            INTEGER,
      prtExPhPlHRate              INTEGER,
      prtExPhPlLRate              INTEGER,
      prtExPhPlProtocol           INTEGER,
      prtExPhPlConnectionTyp      INTEGER,
      prtExPhPlClkMode            INTEGER,
      prtExPhPlDceClkSrc          INTEGER,
      prtExPhPlCongResponse       INTEGER,
      prtExPhPlCongLevel          Integer32,
      prtExPhPlTc                 INTEGER,
      prtExPhPlFlowControl        INTEGER,
      prtExPhPlDcdRts             INTEGER,
      prtExPhPlDcdRtsControlPath  INTEGER,
      prtExPhPlDataBits           INTEGER,
      prtExPhPlParity             INTEGER,
      prtExPhPlStopBits           INTEGER,
      prtExPhPlLXon               Integer32,
      prtExPhPlLXoff              Integer32,
	  prtExPhPlFrMngProt          INTEGER,
	  prtExPhPlEnqPeriod          Integer32,
	  prtExPhPlFullRptPeriod      Integer32,
	  prtExPhPlFrWindowSize       Integer32,
	  prtExPhPlErrorsThreshold    Integer32,
	  prtExPhPlPvcCreateMsg       INTEGER,
	  prtExPhPlCllmMsg            INTEGER,
	  prtExPhPlProtDelayLevel     INTEGER,
	  prtExPhPlClockEncoding      INTEGER,
	  prtExPhPlMinSeparators      Integer32,
	  prtExPhPlCcittCrc           INTEGER,
	  prtExPhPlFrameSeparator     INTEGER,
	  prtExPhPlIdleCode           Integer32,
	  prtExPhPlJitter             Integer32 
	}

prtExPhPlCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg. "
      ::= { prtExPhPlCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.

prtExPhPlSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
     {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
    notApplicable (255)
     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted.
       In the ?004 Unit the entries io6(10)..io12(16) are not valid"
      ::= { prtExPhPlCnfgEntry 2}

prtExPhPlPrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
 {
          exPrt1  (1) ,
          exPrt2  (2) ,
          exPrt3  (3) ,
          exPrt4  (4) ,
          exPrt5  (5) ,
          exPrt6  (6)
       }
      MAX-ACCESS read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique port number.
       In case of PH.1 card, only exPrt(1) is valid."
      ::= { prtExPhPlCnfgEntry 3}

prtExPhPlConnect OBJECT-TYPE
      SYNTAX  INTEGER
       {
  no  (2),
  yes (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the port should be considered
       in any of the mux  algorithms."
      ::= { prtExPhPlCnfgEntry 4}

prtExPhPlHRate OBJECT-TYPE
      SYNTAX  INTEGER
       {
        notApplicable (1),
        r32KbpsNLE    (2),
        r48KbpsNLE    (3),
        r56KbpsNLE    (4),
        r64KbpsNLE    (5),
        r112KbpsNLE   (6),
        r128KbpsNLE   (7),
        r168KbpsNLE   (8),
        r192KbpsNLE   (9),
        r224KbpsNLE  (10),
        r256KbpsNLE  (11),
        r280KbpsE    (12),
        r320KbpsE    (13),
        r336KbpsNLE  (14),
        r384KbpsNLE  (15),
        r392KbpsE    (16),
        r448KbpsNLE  (17),
        r504KbpsLE   (18), -- r504KbpsE 
        r512KbpsE    (19), -- r512KbpsNLE			  
        r560KbpsE    (20),
        r576KbpsLE   (21), -- r576KbpsE
        r616KbpsE    (22),
        r640KbpsE    (23),
        r672KbpsNLE  (24),
        r704KbpsE    (25),
        r728KbpsE    (26),
        r768KbpsNLE  (27),
        r784KbpsE    (28),
        r832KbpsE    (29),
        r840KbpsE    (30),
        r896KbpsNLE  (31),
        r952KbpsE    (32),
        r960KbpsE    (33),
       r1008KbpsLE   (34), -- r1008KbpsE
       r1024KbpsE    (35), -- r1024KbpsNLE
       r1064KbpsE    (36),
       r1088KbpsE    (37),
       r1120KbpsE    (38),
       r1152KbpsLE   (39), -- r1152KbpsE
       r1176KbpsE    (40),
       r1216KbpsE    (41),
       r1232KbpsE    (42),
       r1280KbpsE    (43),
       r1288KbpsE    (44),
       r1344KbpsNLE  (45),
       r1400KbpsE    (46),
       r1408KbpsE    (47),
       r1456KbpsE    (48),
       r1472KbpsE    (49),
       r1512KbpsE    (50),
       r1536KbpsE    (51), -- r1536KbpsNLE
       r1568KbpsE    (52),
       r1600KbpsE    (53),
       r1624KbpsE    (54),
       r1664KbpsE    (55),
       r1680KbpsE    (56),
       r1728KbpsE    (57),
       r1736KbpsE    (58),
       r1792KbpsNLE  (59),
       r1856KbpsE    (60),
       r1920KbpsE    (61),
       r1984KbpsE    (62),
       r2048KbpsE    (63), -- r2048KbpsNLE
--
--  Additional rates for: MAXcess, MP2100h 
--
       r9d6KbpsNLE   (65),
       r14d4KbpsNLE  (66),
       r16KbpsNLE    (67),
       r19d2KbpsNLE  (68),
       r28d8KbpsNLE  (69),
       r38d4KbpsNLE  (70),
       r57d6KbpsNLE  (71), -- For Mx 30/300 Only
       r115d2KbpsNLE (72),  -- For Mx 30/300 Only
       r24000bps     (73)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the port speed for HIGH speed cards.
       The card has limitations about the maximum sigma channel
       speeds and about the possible rates for each clock mode .
       N - The rate is valid for DCE and EXT-DCE Nodal clock mode.
       L - The rate is valid for DCE and EXT-DCE Local clock mode.
       E - The rate is valid for DTE External clock mode.
       'r9d6KbpsNLE' means rate of 9.6 Kbps ('d'=dot).
       
       Note: Some rate attributes have been changed. As the MIB was already
             released with the old attributes, the names of the options were
             not changed. The new names + attributes are in a comment.
             Example:   r2048KbpsE (63), -- r2048KbpsNLE"
      ::= { prtExPhPlCnfgEntry 5}

prtExPhPlLRate  OBJECT-TYPE
      SYNTAX  INTEGER
       {
          notApplicable  (1),
          r300bpsNLE     (2),
          r600bpsNLE     (3),
          r800bpsNLE     (4),
          r1200bpsNLE    (5),
          r2400bpsNLE    (6),
          r4800bpsNLE    (7),
          r9600bpsNLE    (8),
          r14400bpsLE    (9),  -- r14400bpsNLE
          r19200bpsNLE   (10),
          r28800bpsLE    (11), -- r28800bpsNLE
          r32000bpsNLE   (12),
          r38400bpsNLE   (13),
          r48000bpsNLE   (14),
          r56000bpsNLE   (15),
          r57600bpsLE    (16), -- r57600bpsNLE
          r64000bpsNLE   (17),
          r112000bps     (18), -- For Mx 30/300 Only: r112000bpsNLE 
          r115200bps     (19), -- For Mx 30/300 Only: r115200bpsNLE
--
-- additional rates
--
         r16000bpsNLE    (20),
         r100bpsNLE      (21), -- For Mx 30/300 Only
         r128000bps      (22), -- For Mx 30/300 Only
         r24000bps       (23)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the port speed for LOW speed cards.
       The card has limitations about the possible rates for each
       clock mode.
       N - The rate is valid for DCE and EXT-DCE Nodal clock mode.
       L - The rate is valid for DCE and EXT-DCE Local clock mode.
       E - The rate is valid for DTE External clock mode.

       Note: Some rate attributes have been changed. As the MIB was already
             released with the old attributes, the names of the options were
             not changed. The new names + attributes are in a comment.
             Example:  r57600bpsLE (16), -- r57600bpsNLE  "

      ::= { prtExPhPlCnfgEntry 6}

prtExPhPlProtocol OBJECT-TYPE
      SYNTAX  INTEGER
     {
        fr                 (1),
        frPlus             (2),
        pCellRelay         (3),
        hdlcSdlc           (4),
        transparentHdlc    (5),
        async              (6),
        asyncReliable      (7),
        activePPP          (8),
        slip               (9),
        pppAgent           (10),
        slipAgent          (11),
        transparent        (12),
        sna                (13),
		ft1Dot2            (14) -- Standard IEC 870-5-1 for Frame Transport
     }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the applied protocol."
      ::= { prtExPhPlCnfgEntry 7}

prtExPhPlConnectionTyp OBJECT-TYPE
      SYNTAX  INTEGER
     {
     sameNetManaged  (1),
     sameNetNotMana  (2),
     user            (3),
     otherNet        (4),
     pubNet          (5),
        notApplicable (255)
     }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the link connection type.
       It is required for three reasons:
     FR/CR Inband management opration (LMI,CLMM...).
     CIR check.
     NMS network management.

       SameNetManaged - indicates network internal line.
       SameNetMotMana - indicates network internal line, but the
                        remote mux is not managed by the NMS.

       User           - User to Network Interface.
       OtherNet       - Network To Network Interface.
       PubNet         - Access Mux To PubNet Interface."
      ::= { prtExPhPlCnfgEntry 8}

prtExPhPlClkMode OBJECT-TYPE
      SYNTAX  INTEGER
              {
                  dce     (1),
                  extDce  (2),
                  dte     (3),
      int     (4),
      lbt     (5)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Clock mode."
      ::= { prtExPhPlCnfgEntry 9}

prtExPhPlDceClkSrc OBJECT-TYPE
      SYNTAX  INTEGER
              {
                  notApplicable (1),
                  local         (2),
                  nodalTiming   (3)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the source of the clock when working
       in dce or ext-dce clock mode.
       notApplicable(1) - is applied for dte(3) and lbt(5) clock modes.
	                      When clock mode is dte, the clock source is
						  always external, therefore this object's value is
						  notApplicable.
       local(2) and nodalTiming(3) - are valid in dce(1), extDce(2)
                                     or int(4) clock modes.
       The recommended clock source is local(2)."
      ::= { prtExPhPlCnfgEntry 10}

prtExPhPlCongResponse OBJECT-TYPE
      SYNTAX  INTEGER
     {
        no                  (2),
        flowControl         (3), -- duplex, to/from flow control
        toFlowControl       (4)  -- simplex , only to flow control
     }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
"This attribute indicates how to handle the congestion indication
 to/from the mux internal connection side (for example
 transmit/received becn to/from the network).
   no           - do nothing
   flowControl  - translates the congestion indication between the
                  port and the internal connection port according
                  to the definition of the prtInPh1MlFlowControl
                  parameters. The operation is done on both
                  directions.
   toFlowControl- translates the backward congestion indication
                  received from the internal connection port
                  (normally the network side) to flow control and
                  do nothing in the other direction."
      ::= { prtExPhPlCnfgEntry 11}

prtExPhPlCongLevel OBJECT-TYPE
      SYNTAX  Integer32 (0..70)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the level of delayed data in
       precents of total available dynamic memory,
       for which the port will start to operate as congested.
       The resolution of the parameter is 5 percent."
      ::= { prtExPhPlCnfgEntry 12}

prtExPhPlTc OBJECT-TYPE
      SYNTAX  INTEGER
          {
          tc1sec  (1),
          tc2sec  (2),
          tc3sec  (3),
          tc4sec  (4),
    notApplicable (255)
          }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Tc parameter which is the time
       period of the sliding window in which the Bc/Be are tested.
       The value of this parameter is identical for all the ports
       of a  specific card ."
      ::= { prtExPhPlCnfgEntry 13}

prtExPhPlFlowControl OBJECT-TYPE
      SYNTAX  INTEGER
     {
        none                (2),
        fecnBecn            (3),
        xonXoff             (4),
        dtrCts              (5),
        speedReduction      (6)   -- simplex response only congestion to flow control
     }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the required flow control betweeen
       the port and the remote equipment.
       fecnBecn - is valid only for FR, FR+ and CR protocols.
       xonXoff,dtrCts - are valid only for Async protocols.
       speedReduction - is valid only for DLC protocol when the
                        Clock Mode is DCE and the Clock Source is
                        Local."
      ::= { prtExPhPlCnfgEntry 14}

prtExPhPlDcdRts OBJECT-TYPE
      SYNTAX  INTEGER
     {
        notApplicable     (1),
        on                (2),
        endToEnd          (3)
     }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Protocol may require end to end connect indication over the
       network. End to end link connection establishment over the
       FR network will be indicated to the user by using DCD or
       RTS control signals, depending on the clock mode: DCE or
       DTE respectively.
       The options are :
       - On :
              DCD(DCE)/RTS(DTE) will be constantly ON no matter
              if the End to End connection is established or not.
       - End to End:
              The DCD(DCE)/RTS(DTE) will be according to the status
              of the End to End connection."
      ::= { prtExPhPlCnfgEntry 15}

prtExPhPlDcdRtsControlPath OBJECT-TYPE
      SYNTAX  INTEGER
     {
        notApplicable     (1),
        off               (2),
        on                (3)
     }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Protocol may require end to end connect indication over the
       network. This parameter defines whether to take the user
       connection status (RTS(DCE)/DCD(DTE)) and forward it to the
       network side.
      - on : Transmit active connection to the network regardless
              the RTS/DCD control lines status.
      - off: Transmit active connection to the network according
              to the status of the RTS/DCD pin. "
      ::= { prtExPhPlCnfgEntry 16}

prtExPhPlDataBits OBJECT-TYPE
      SYNTAX  INTEGER
         {
         notApplicable  (1),
         dataBits7Bits (2),
         dataBits8Bits (3)
         }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the number of data bits in async
       frame.
       It is relevant only for Async protocols."
      ::= { prtExPhPlCnfgEntry 17}

prtExPhPlParity OBJECT-TYPE
      SYNTAX  INTEGER
         {
         notApplicable  (1),
         odd            (2),
         even           (3),
         none           (4)
         }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the parity operation mode in
       async frame.
       It is relevant only for Async protocols."
      ::= { prtExPhPlCnfgEntry 18}

prtExPhPlStopBits OBJECT-TYPE
      SYNTAX  INTEGER
         {
         notApplicable  (1),
         sb1Bit           (2),
         sb1dot5Bits      (3),
         sb2Bits          (4)
         }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the minimum number of stop bits
       in the tx async frame.
       It is relevant only for Async protocols."
      ::= { prtExPhPlCnfgEntry 19}

prtExPhPlLXon OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the character used as X-On to
       notify receive enable.
       This parameter is valid only for async protocols.
    Valid values: 0..255.
       The value 256 indicates that it's not applicable "
      ::= { prtExPhPlCnfgEntry 20}

prtExPhPlLXoff OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the character used as X-Off to
       notify receive disable.
       This parameter is valid only for async protocols.
    Valid values: 0..255.
       The value 256 indicates that it's not applicable "
      ::= { prtExPhPlCnfgEntry 21}

prtExPhPlFrMngProt OBJECT-TYPE
      SYNTAX  INTEGER
   {
   notApplicable (1),
   none          (2),
   lmi           (3),
   ansiT1        (4),  --Annex D
   annexA        (5)
   }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the Frame-Relay management protocol.
       ansiT1 = ANSI T1.617 Annex D (this is the default value).
       This parameter is applicable only for FR and FR+ protocols.
       When prtExPhPlConnectionTyp = sameNetManaged, this object
       will be RO (internally determined). "
      ::= { prtExPhPlCnfgEntry 22}

prtExPhPlEnqPeriod OBJECT-TYPE
      SYNTAX  Integer32 (1..30)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object is the Status Enquiry Period, in seconds.
       It determines the frequency of the Status Enquiry message
       as sent by the FR user side.
       At the FR network side, it determines the timeout for this
       message reception.
    Default = 4 seconds.
       This parameter is applicable only for FR and FR+ protocols
    AND
       only when prtExPhPlFrMngProt is NOT (notApplicable or none)."
    ::= { prtExPhPlCnfgEntry 23}

prtExPhPlFullRptPeriod OBJECT-TYPE
      SYNTAX  Integer32 (1..255)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object is the Full Report Frequency.
       It determines the number of the Status Enquiry messages
       sent by the FR user side, before a Full Report Request is
       sent.
       The units are : Status Enquiry messages (periods).
    Valid values: 1 .. 255.
       255 = infinite.
       This parameter is applicable only for FR and FR+ protocols
    AND
       only when prtExPhPlFrMngProt is NOT (notApplicable or none)."
    ::= { prtExPhPlCnfgEntry 24}

prtExPhPlFrWindowSize OBJECT-TYPE
      SYNTAX  Integer32 (1..10)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object is the FR Window Size.
       It determines the number of samplings in the sliding window
       that counts the errors.
       This parameter is applicable only for FR and FR+ protocols
    AND
       only when prtExPhPlFrMngProt is NOT (notApplicable or none)."
    ::= { prtExPhPlCnfgEntry 25}

prtExPhPlErrorsThreshold OBJECT-TYPE
      SYNTAX  Integer32 (1..10)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object is the Max Errors.
       It determines the number of Status Enquiry Errors that
       occured within the FR sliding window, before this port is
       considered DOWN (threshold).
       This parameter is applicable only for FR and FR+ protocols
    AND
       only when prtExPhPlFrMngProt is NOT (notApplicable or none)."
    ::= { prtExPhPlCnfgEntry 26}

prtExPhPlPvcCreateMsg OBJECT-TYPE
      SYNTAX  INTEGER
   {
   notApplicable (1),
   no            (2),
   yes           (3)
   }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object is Update Message (if required or not).
       It determines whether a message of a New PVC Creation is
       requested or not (yes/no).
       Default = no.
       This parameter is applicable only for FR and FR+ protocols
    AND
       only when prtExPhPlFrMngProt is NOT (notApplicable or none)."
    ::= { prtExPhPlCnfgEntry 27}

prtExPhPlCllmMsg OBJECT-TYPE
      SYNTAX  INTEGER
   {
   notApplicable (1),
   no            (2),
   yes           (3)
   }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object is CLLM Message (if required or not).
       It determines whether to send (or not) a congestion message
       when the port is Rx congested.
       Default = no.
       This parameter is applicable only for FR and FR+ protocols
    AND
       only when prtExPhPlFrMngProt is NOT (notApplicable or none)."
    ::= { prtExPhPlCnfgEntry 28}

prtExPhPlProtDelayLevel OBJECT-TYPE
      SYNTAX  INTEGER
	  {
	  notApplicable (1),
	  s36Byte       (2),  --level 1
	  s150Byte      (3),  --level 2
	  s264Byte      (4),  --level 3
	  s378Byte      (5),  --level 4
	  s492Byte      (6)	  --level 5
	  }
      MAX-ACCESS  read-write
      STATUS  current

      DESCRIPTION
      "This object is the Segmentation in Bytes.
       	In some cases, the enumerated values will mean
	    other segmentation values than specified:

	   Product:    MX-3000 	    MX-3000 	   MX-300/MX-30
	   Protocol:     FR+     	Transparent		FR+
	   -----------------------------------------------------
	   level 1     50 Bytes		44 Bytes		50 Bytes
	   level 2    158 Bytes	   155 Bytes	   158 Bytes
	   level 3    266 Bytes	   266 Bytes	   266 Bytes
	   level 4    376 Bytes	   377 Bytes	   376 Bytes
	   level 5    484 Bytes	   488 Bytes	   484 Bytes

	   Defval=level 1 value

       This parameter is applicable only for FR+ and
       transparent protocols."
	   ::= { prtExPhPlCnfgEntry 29}

prtExPhPlClockEncoding OBJECT-TYPE
      SYNTAX  INTEGER
	  {
	  notApplicable (1),
	  nrz           (2),
	  nrzI          (3),
	  fm0           (4),
	  manchester    (5),
	  diffManchester(6),
	  nrzISpace     (7),
	  nrzIMark      (8)
	  }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object is the Encoding type of the Line.
       This parameter is applicable only for FR and FR+ protocols.
       For MAXCESS 3000 & MP2100H: when setting to nrzI (3) the nrzI works
       as nrzI Mark.
       For MAXCESS 30/300 when setting to nrzI (3) the nrzI works as nrzI Space."
	   ::= { prtExPhPlCnfgEntry 30}

prtExPhPlMinSeparators OBJECT-TYPE
      SYNTAX  Integer32 (0..16)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Minimum number of bytes separating between two adjacent frames (HDLC item).
       0 = notApplicable"
	   ::= { prtExPhPlCnfgEntry 31}

prtExPhPlCcittCrc OBJECT-TYPE
      SYNTAX  INTEGER
	  {
	  notApplicable (1),
	  crc16         (2),
	  crc32         (3)
	  }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates how many Bits are used for CRC (HDLC item)."
	   ::= { prtExPhPlCnfgEntry 32}

prtExPhPlFrameSeparator OBJECT-TYPE
      SYNTAX  INTEGER
	  {
	  notApplicable (1),
	  idles         (2),
	  flags         (3)
	  }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates what should be transferred on the line when there
       are no frames to pass (HDLC item).
       idles: mean that FF will pass on the line
       flags: mean that 7E will pass on the line."
	   ::= { prtExPhPlCnfgEntry 33}

prtExPhPlIdleCode       OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Determines the code for transmission when there are no frames to transmit 
       on the line. The value should be 0 to FFH."
	   ::= { prtExPhPlCnfgEntry 34}

prtExPhPlJitter OBJECT-TYPE
      SYNTAX  Integer32  (0..1000)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Maximum variant delay of the FR network, in msec."
 	   ::= { prtExPhPlCnfgEntry 35}

--
-- PH.1 & PH.3
-- External port Dlci table
--
prtExPhPlDlciTable  OBJECT-TYPE
     SYNTAX SEQUENCE OF PrtExPhPlDlciEntry
     MAX-ACCESS not-accessible
     STATUS  current
     DESCRIPTION
      "The write operation into the Table Objects is valid only
       at the TmpCnfg entry."
     ::= {prtPhPlCnfg 2}

prtExPhPlDlciEntry OBJECT-TYPE
      SYNTAX PrtExPhPlDlciEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtExPhPlDlciCnfgIdx, prtExPhPlDlciSltIdx, prtExPhPlDlciPrtIdx, prtExPhPlDlciIdx }
      ::= { prtExPhPlDlciTable 1}

PrtExPhPlDlciEntry ::=
      SEQUENCE {
      prtExPhPlDlciCnfgIdx        Integer32,
      prtExPhPlDlciSltIdx         INTEGER,
      prtExPhPlDlciPrtIdx         INTEGER,
      prtExPhPlDlciIdx            Integer32,

      prtExPhPlDlciValid          INTEGER,
      prtExPhPlDlciIConSlt        INTEGER,
      prtExPhPlDlciIConPrt        INTEGER,
      prtExPhPlDlciIConDlci       Integer32,

      prtExPhPlDlciTxBc           INTEGER,
      prtExPhPlDlciTxBe           INTEGER,
      prtExPhPlDlciRxBc           INTEGER,
      prtExPhPlDlciRxBe           INTEGER,

      prtExPhPlDlciPriority       Integer32,

      prtExPhPlDlciStatus         INTEGER
      }


prtExPhPlDlciCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg. "
      ::= { prtExPhPlDlciEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.

prtExPhPlDlciSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
     {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
    notApplicable (255)
     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted.
       In the ?004 Unit the entries io6(10)..io16) are not valid"
      ::= { prtExPhPlDlciEntry 2}

prtExPhPlDlciPrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
 {
          exPrt1  (1) ,
          exPrt2  (2) ,
          exPrt3  (3) ,
    exPrt4  (4) ,
    exPrt5  (5) ,
    exPrt6  (6)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique internal port number.
       PH.1/E1 and PH.1/T1 cards have three internal ports.
       Stand-alone units may have six such ports."
      ::= { prtExPhPlDlciEntry 3}

prtExPhPlDlciIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..991)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique index for each possible
       used dlci(16..991). When the protocol is not Multiplexing
       protocol, its type is 'user' and the only valid index is 1."
      ::= { prtExPhPlDlciEntry 4}

prtExPhPlDlciValid OBJECT-TYPE
      SYNTAX  INTEGER
     {
     no  (2),
     yes (3)
     }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the attributes in this
       entry are valid or not. The user can add/delete pvc (dlci
       to dlci connection) by modifing this object"
      ::= { prtExPhPlDlciEntry 5}

prtExPhPlDlciIConSlt OBJECT-TYPE
      SYNTAX  INTEGER
 {
          noConnect (2),
    cl    (3),
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
    notApplicable (255)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique slot position In the Mux
       (Agent) where the dlci is routed to.
    cl - will represent any of the CL slots. This value can be
         selected for multiple DLCIs of the product.
       In the ?004 Unit the entries io6(10)..io16) are not valid"
      ::= { prtExPhPlDlciEntry 6}

prtExPhPlDlciIConPrt OBJECT-TYPE
      SYNTAX  INTEGER
      {
       exPrt1    (1) ,
       exPrt2    (2) ,
       exPrt3    (3) ,
       exPrt4    (4) ,
       exPrt5    (5) ,
       exPrt6    (6) ,
       exPrt7    (7) ,
       exPrt8    (8) ,
       exPrt9    (9) ,
       exPrt10  (10) ,
    clNMS      (99),
          noConnect (100),
       inPrt1  (101) ,
       inPrt2  (102) ,
       inPrt3  (103) ,
       inPrt4  (104) ,
       inPrt5  (105) ,
       inPrt6  (106) ,
       inPrt7  (107) ,
       inPrt8  (108) ,
       inPrt9  (109) ,
       inPrt10 (110)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique port id which the dlci is
       routed to.
       clNMS - will be used for NMS SNMP messages. It can be any
               port of the CL card.
               This value will be selectable only if
               prtExPhPlDlciIConSlt='cl' or 'notApplicable'."
      ::= { prtExPhPlDlciEntry 7}


prtExPhPlDlciIConDlci OBJECT-TYPE
      SYNTAX  Integer32    (1..991)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique internal connection dlci
       number,  the dlci is routed to."
      ::= { prtExPhPlDlciEntry 8}

prtExPhPlDlciTxBc OBJECT-TYPE
      SYNTAX  INTEGER
        {
         full       (1),
         zero       (2),
         txBc9600bps    (3),
        txBc14400bps    (4),
        txBc19200bps    (5),
        txBc28800bps    (6),
        txBc32000bps    (7),
        txBc38400bps    (8),
        txBc48000bps    (9),
        txBc56000bps   (10),
        txBc57600bps   (11),
          txBc64Kbps   (12),
         txBc128Kbps   (13),
         txBc192Kbps   (14),
         txBc256Kbps   (15),
         txBc320Kbps   (16),
         txBc384Kbps   (17),
         txBc448Kbps   (18),
         txBc512Kbps   (19),
         txBc768Kbps   (20),
        txBc1024Kbps   (21),
--
--KM30 ; KM300 additional rates
--
        txBc16000bps   (25),
   txBc112Kbps   (26)
        }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique Tx committed bandwidth on
       the user transmit line (or at the port receive line)."
      ::= { prtExPhPlDlciEntry 9}


prtExPhPlDlciTxBe OBJECT-TYPE
      SYNTAX  INTEGER
        {
         full       (1),
         zero       (2),
         txBe9600bps    (3),
        txBe14400bps    (4),
        txBe19200bps    (5),
        txBe28800bps    (6),
        txBe32000bps    (7),
        txBe38400bps    (8),
        txBe48000bps    (9),
        txBe56000bps   (10),
        txBe57600bps   (11),
          txBe64Kbps   (12),
         txBe128Kbps   (13),
         txBe192Kbps   (14),
         txBe256Kbps   (15),
         txBe320Kbps   (16),
         txBe384Kbps   (17),
         txBe448Kbps   (18),
         txBe512Kbps   (19),
         txBe768Kbps   (20),
        txBe1024Kbps   (21),
--
--KM30 ; KM300 additional rates
--
        txBc16000bps   (25),
   txBc112Kbps   (26)
        }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique Tx excess bandwidth on the
      user transmit line (or at the port receive line)."
      ::= { prtExPhPlDlciEntry 10}


prtExPhPlDlciRxBc OBJECT-TYPE
      SYNTAX  INTEGER
        {
         full       (1),
         zero       (2),
         rxBc9600bps    (3),
        rxBc14400bps    (4),
        rxBc19200bps    (5),
        rxBc28800bps    (6),
        rxBc32000bps    (7),
        rxBc38400bps    (8),
        rxBc48000bps    (9),
        rxBc56000bps   (10),
        rxBc57600bps   (11),
        rxBc64Kbps   (12),
         rxBc128Kbps   (13),
         rxBc192Kbps   (14),
         rxBc256Kbps   (15),
         rxBc320Kbps   (16),
         rxBc384Kbps   (17),
         rxBc448Kbps   (18),
         rxBc512Kbps   (19),
         rxBc768Kbps   (20),
        rxBc1024Kbps   (21),
--
--KM30 ; KM300 additional rates
--
        rxBc16000bps   (25),
   rxBc112Kbps   (26)
        }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique Rx committed bandwidth on the
      user receive line (or at the port transmit line)."
      ::= { prtExPhPlDlciEntry 11}


prtExPhPlDlciRxBe OBJECT-TYPE
      SYNTAX  INTEGER
        {
         full       (1),
         zero       (2),
         rxBe9600bps    (3),
        rxBe14400bps    (4),
        rxBe19200bps    (5),
        rxBe28800bps    (6),
        rxBe32000bps    (7),
        rxBe38400bps    (8),
        rxBe48000bps    (9),
        rxBe56000bps   (10),
        rxBe57600bps   (11),
          rxBe64Kbps   (12),
         rxBe128Kbps   (13),
         rxBe192Kbps   (14),
         rxBe256Kbps   (15),
         rxBe320Kbps   (16),
         rxBe384Kbps   (17),
         rxBe448Kbps   (18),
         rxBe512Kbps   (19),
         rxBe768Kbps   (20),
        rxBe1024Kbps   (21),
--
--KM30 ; KM300 additional rates
--
        rxBc16000bps   (25),
   rxBc112Kbps   (26)
        }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique Rx excess bandwidth on the
      user receive line (or at the port transmit line)."
      ::= { prtExPhPlDlciEntry 12}


prtExPhPlDlciPriority OBJECT-TYPE
      SYNTAX  Integer32  (1..8)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique priority of the pcv.
       1 is the lowest priority and 8 is the highest priority."
      ::= { prtExPhPlDlciEntry 13}


prtExPhPlDlciStatus OBJECT-TYPE
      SYNTAX  INTEGER
 {
          disconnected (1),
          connected    (2)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the status of the pvc. The status is
       disconnected(1) when one of the sides is programmed as not
       connected"
      ::= { prtExPhPlDlciEntry 14}


-- Parameters of an external Modem which is connected to a High/Low Speed
-- Port.

prtExPhPlModemTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtExPhPlModemEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION "External Modem Parameters.
      The write operation into the
      Table Objects is valid only for the TmpCnfg entry."
      ::= {prtPhPlCnfg 3}

prtExPhPlModemEntry OBJECT-TYPE
      SYNTAX PrtExPhPlModemEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtExPhPlModemCnfgIdx,prtExPhPlModemSltIdx,prtExPhPlModemPrtIdx}
      ::= { prtExPhPlModemTable 1}

PrtExPhPlModemEntry ::=
      SEQUENCE {
      prtExPhPlModemCnfgIdx           Integer32,
      prtExPhPlModemSltIdx            INTEGER,
      prtExPhPlModemPrtIdx            INTEGER,
      prtExPhPlModemStatus            INTEGER,
      prtExPhPlModemActivate          INTEGER,
      prtExPhPlModemMaxIdleTime       Integer32,
      prtExPhPlModemTimeBtwnCalls     Integer32,
	  prtExPhPlModemCallDelay         Integer32 
	}

prtExPhPlModemCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg. "
      ::= { prtExPhPlModemEntry 1}

prtExPhPlModemSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
     {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
       notApplicable (255)
     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted.
       In the ?004 Unit the entries io6(10)..io12(16) are not valid"
      ::= { prtExPhPlModemEntry 2}

prtExPhPlModemPrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
 {
          exPrt1  (1) ,
          exPrt2  (2) ,
          exPrt3  (3) ,
          exPrt4  (4) ,
          exPrt5  (5) ,
          exPrt6  (6)
       }
      MAX-ACCESS read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique port number.
       In case of PH.1 card, only exPrt(1) is valid."
      ::= { prtExPhPlModemEntry 3}

prtExPhPlModemStatus OBJECT-TYPE
      SYNTAX INTEGER
      {
       disable (2),
       enable  (3),
	   relay   (4)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates whether a Dial Up Modem is enabled on this port.
       Default: disable
       
       For Vmux devices this object shows whether there is Modem Relay support."       
      ::= { prtExPhPlModemEntry 4}

prtExPhPlModemActivate OBJECT-TYPE
      SYNTAX INTEGER
     {
      onFirstFrame(2),
      always    (3),
      notApplicable (255)
     }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates whether the Dial Up Modem is activated when
       the first frame is received or it is always activated.
       Default: onFirstFrame"
      ::= { prtExPhPlModemEntry 5}

prtExPhPlModemMaxIdleTime OBJECT-TYPE
      SYNTAX Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Max Time allowed in Seconds without any traffic before the line
       is disconnected.

       Legal Values are: 1 sec, 2 sec .. 5 sec, 10 sec, 20 sec..
       1 min, 2 min .. 10 min, 15 min, 20 min, 25 min, 30 min.
       65535 sec. means that this parameter is not applicable. 

       Default: 1 sec."
       ::= { prtExPhPlModemEntry 6}

prtExPhPlModemTimeBtwnCalls OBJECT-TYPE
      SYNTAX Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Minimum Time in Seconds which is required after a call was
       disconnected. In this time no other call will be initiated
       from this Modem port even if there were frames transmitted
       to this port. This time is required for some Modems which
       have initializations that take a few seconds.
       
       Legal Values are:
	   0 sec. - 30 sec., 1-5 min.
       65535 sec. means that this parameter is not applicable. 

       Default: 0 sec"
       ::= { prtExPhPlModemEntry 7}

prtExPhPlModemCallDelay OBJECT-TYPE
      SYNTAX Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Time in Seconds that the device will wait before dialing to the remote
	   device.
	   
	   This feature is mostly used when there is a backup modem to the 
	   main link and the main link is down. In this case it is important to prevent
	   the 2 devices from dialing through the backup modems to each other at the same time.
	   It is advised to configure one side with a small call delay and the other side
	   with a large call delay.
       
       Legal Values are:
	   0 - 30, 60, 120, 180, 240, 300, 600, 900, 1200, 1500, 1800 . 
       65535 sec. means that this parameter is not applicable. 

       Default: 0 sec"
       ::= { prtExPhPlModemEntry 8}

--
-- Megaplex ?000/?004 LS-2 TDM I/O family card include:
-- Ls2-CCITT-X.50, Ls2-CCITT-X.58, Ls2-AT&T-SDM
--
--prtExLs2CnfgTable OBJECT IDENTIFIER ::= {prtLs2Cnfg 1}
--prtInLs2CnfgTable OBJECT IDENTIFIER ::= {prtLs2Cnfg 2}

prtExLs2CnfgTable OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtExLs2CnfgEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
       "The write operation into the Table Objects is valid only
        to the TmpCnfg entry."
      ::= {prtLs2Cnfg 1}

prtExLs2CnfgEntry OBJECT-TYPE
      SYNTAX PrtExLs2CnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtExLs2CnfgIdx, prtExLs2SltIdx, prtExLs2PrtIdx }
      ::= {prtExLs2CnfgTable  1}

PrtExLs2CnfgEntry ::=
      SEQUENCE {
        prtExLs2CnfgIdx   Integer32,
        prtExLs2SltIdx    INTEGER,
        prtExLs2PrtIdx    INTEGER,
        prtExLs2Connect   INTEGER,
        prtExLs2Rate      INTEGER,
        prtExLs2ClkMode   INTEGER,
        prtExLs2Cts       INTEGER,
        prtExLs2Dcd       INTEGER,
        prtExLs2EnvIdx    Integer32 
	}

prtExLs2CnfgIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx  255 relates to the TmpCnfg"
      ::= {prtExLs2CnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.

prtExLs2SltIdx OBJECT-TYPE
      SYNTAX  INTEGER
          {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted.
       In the ?004 Unit the entries io6(10)..io16) are not valid."
      ::= {prtExLs2CnfgEntry 2}

prtExLs2PrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
          {
          exPrt1    (1) ,
          exPrt2    (2) ,
          exPrt3    (3) ,
          exPrt4    (4) ,
          exPrt5    (5) ,
          exPrt6    (6) ,
          exPrt7    (7) ,
          exPrt8    (8) ,
          exPrt9    (9) ,
          exPrt10  (10)
          }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  port index.
      For the Ls2/X.58 exPrt(7)..exPrt(10) are not valid."
      ::= {prtExLs2CnfgEntry 3}


prtExLs2Connect OBJECT-TYPE
      SYNTAX  INTEGER
              {
                no  (2),
                yes (3)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the  port  should be
       considered in any of the mux algorithms."
      ::= {prtExLs2CnfgEntry 4}

prtExLs2Rate OBJECT-TYPE
      SYNTAX  INTEGER
       {
          r2400bps  (2),
          r4800bps  (3),
          r9600bps  (4),
          r19200bps (5)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Port rates."
      ::= {prtExLs2CnfgEntry 5}

prtExLs2ClkMode OBJECT-TYPE
      SYNTAX  INTEGER
       {
          dce     (1),
          ext-dce (2),
          dte     (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique port operation clock mode."
      ::= {prtExLs2CnfgEntry 6}

prtExLs2Cts OBJECT-TYPE
      SYNTAX  INTEGER
       {
    on       (2),
    rts-min  (3),
    rts-max  (4)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "CTS."
      ::= {prtExLs2CnfgEntry 7}

prtExLs2Dcd OBJECT-TYPE
      SYNTAX  INTEGER
       {
    on        (2),
    card-sync (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "DCD."
      ::= {prtExLs2CnfgEntry 8}

prtExLs2EnvIdx OBJECT-TYPE
      SYNTAX  Integer32 (0..24)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Envelope Index.
       When prtInLs2EnvAssign=auto, the value is 0 (not applicable)."
      ::= {prtExLs2CnfgEntry 9}

-- Ls2 Internal composit channel parameters
--
prtInLs2CnfgTable OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtInLs2CnfgEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
       "The write operation into the Table Objects is valid only
        to the TmpCnfg entry."
      ::= {prtLs2Cnfg 2}

prtInLs2CnfgEntry OBJECT-TYPE
      SYNTAX PrtInLs2CnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtInLs2CnfgIdx, prtInLs2SltIdx, prtInLs2PrtIdx }
      ::= {prtInLs2CnfgTable 1}

PrtInLs2CnfgEntry ::=
      SEQUENCE {
        prtInLs2CnfgIdx   Integer32,
        prtInLs2SltIdx    INTEGER,
        prtInLs2PrtIdx    INTEGER,
        prtInLs2Connect   INTEGER,
        prtInLs2Group     Integer32,
        prtInLs2Member    Integer32,
        prtInLs2LinkTo    INTEGER,
        prtInLs2EnvAssign INTEGER
      }

prtInLs2CnfgIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx  255 relates to the TmpCnfg"
      ::= {prtInLs2CnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.

prtInLs2SltIdx OBJECT-TYPE
      SYNTAX  INTEGER
          {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted.
       In the ?004 Unit the entries io6(10)..io16) are not valid."
      ::= {prtInLs2CnfgEntry 2}

prtInLs2PrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
          {
          inPrt1    (101),
    inPrt2    (102)
          }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique internal port index."
      ::= {prtInLs2CnfgEntry 3}

prtInLs2Connect OBJECT-TYPE
      SYNTAX  INTEGER
              {
                no  (2),
                yes (3)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the port should be considered in
       any of the mux  algorithms. It also affects all the module
       considerations because the module has only one Internal
       interface which is the composite channel."
      ::= {prtInLs2CnfgEntry 4}

prtInLs2Group OBJECT-TYPE
      SYNTAX  Integer32 (1..12)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the group number of the port.
       LS-2 internal ports with the same group number share the same Time slot of the main
       link"
      ::= {prtInLs2CnfgEntry 5}

prtInLs2Member OBJECT-TYPE
      SYNTAX  Integer32 (1..4)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the group member id of the port.
       This parameter is for the automatic envelope assignment
       algorithm."
      ::= {prtInLs2CnfgEntry 6}

prtInLs2LinkTo OBJECT-TYPE
      SYNTAX  INTEGER
       {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
       }
      MAX-ACCESS  read-write
      STATUS  deprecated
      DESCRIPTION
      "It indicates the slot of the main link card to which the
       LS2 card is mapped.
       STATUS  deprecated - this object is replaced by prtGenCnfgLinkToSlot
       and prtGenCnfgLinkToPort."
      ::= {prtInLs2CnfgEntry 7}

prtInLs2EnvAssign OBJECT-TYPE
      SYNTAX  INTEGER
       {
        auto    (2),
        manual  (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Envelope assignment type."
      ::= {prtInLs2CnfgEntry 8}


--
-- Megaplex?000/?004 VC-2, VC-6, VC-2/R2, VC-Q TDM I/O family port.
-- (Vc2E&m,Vc2Fxs1Plar,Vc2Fxo1,Vc2Fxs2,Vc2Fxo2,Vc2Fxs3,Vc2Fxo3)
-- Vc6E&M, Vc6Fxo, Vc6Fxs, Vc6aE&M, Vc6aFxo, Vc6aFxs
-- Vc2/R2(Fxs)
-- VC-Q
-- VC-12, VC-12/6
-- VC-8,  VC-16

prtVc2CnfgTable OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtVc2CnfgEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
       "- For products supporting more than one configuration, the write operation 
          into the Table is valid only to the TmpCnfg entry.
        - For products that do not support configurations, the write operation 
          into the Table will be to prtVc2CnfgIdx=1."
      ::= { cnfgPrtMux 5}

prtVc2CnfgEntry OBJECT-TYPE
      SYNTAX PrtVc2CnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtVc2CnfgIdx, prtVc2SltIdx, prtVc2PrtIdx }
      ::= { prtVc2CnfgTable 1}

PrtVc2CnfgEntry ::=
      SEQUENCE {
        prtVc2CnfgIdx       Integer32,
        prtVc2SltIdx        INTEGER,
        prtVc2PrtIdx        Integer32,

        prtExVc2Connect     INTEGER,
        prtExVc2TransGain   Integer32,
        prtExVc2ReceiveGain Integer32,
        prtExVc2Wire        INTEGER,
        prtExVc2CodingLaw   INTEGER,
        prtExVc2Sig         INTEGER,
        prtExVc2Oos         INTEGER,
        prtExVc2LinkTo      INTEGER,
        prtExVc2OperMode    INTEGER,
        prtExVc2SigProfile  INTEGER,
        prtExVc2CallEnable  INTEGER,
        prtExVc2R2Delay     INTEGER,
        prtExVc2CasStd      INTEGER,
        prtExVc2EchoCanceler INTEGER,
        prtExVc2IfType      INTEGER,
        prtExVc2Encoding    INTEGER,
        prtExVc2TxBitCode   OCTET STRING,
        prtExVc2RxBitOutput OCTET STRING,
		prtExVc2MeterRate   INTEGER,
		prtExVc2IfSignaling INTEGER,
        prtExVc2SeizeAck    INTEGER,
        prtExVc2EandMType   INTEGER,
		prtExVc2RemType     INTEGER,
		prtExVc2ConvTime    INTEGER,
		prtExVc2SigFeedback INTEGER,
		prtExVc2EchoCancelerModule INTEGER,
		prtExVc2ReversePolarity    INTEGER,
		prtExVc2RingerFrequency    INTEGER,
		prtExVc2SigService         INTEGER,
		prtExVc2CallerIdEnable     INTEGER,
		prtExVc2CompressMethod     INTEGER,
		prtExVc2ObMode             INTEGER,
		prtExVc2VAD                INTEGER,
		prtExVc2NoiseLevelForVAD   INTEGER,
		prtExVc2WesternSigMode     INTEGER,
		prtExVc2BusProtectionPoint INTEGER,	--not used
		prtExVc2ImpedanceStandard  INTEGER
      }

prtVc2CnfgIdx OBJECT-TYPE
      SYNTAX  Integer32  (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx  255 relates to the TmpCnfg"
      ::= {prtVc2CnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.

prtVc2SltIdx OBJECT-TYPE
      SYNTAX  INTEGER
 {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
       notApplicable (255)
 }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted.
       For Stand Alone products like WR: notApplicable (255)"
      ::= {prtVc2CnfgEntry 2}

prtVc2PrtIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A unique identifier of the port, within the card.
       For MP-2100/2200 card ports, Web Ranger and FCD-IP Voice ports 
 	   the values will be:
       exPrt1    (1) 
       exPrt2    (2) 
       exPrt3    (3) 
       exPrt4    (4) 
       exPrt5    (5) 
       exPrt6    (6) 
       exPrt7    (7) 
       exPrt8    (8) 
       exPrt9    (9) 
       exPrt10  (10) 
       exPrt11  (11) 
       exPrt12  (12)
       exPrt13  (13) 
       exPrt14  (14) 
       exPrt15  (15) 
       exPrt16  (16) 
 	   
	   For LA-240:
	     The index for fixed voice ports will be - 
	       exPrt6    (6) 
           exPrt7    (7) 
           exPrt8    (8) 
           exPrt9    (9) 
		 The index for voice card ports will be - 
		   Slot number * 100 + ch (for IO-1: 101..104, for IO-2: 201..204).
	   For other products' index see their specification."
      ::= {prtVc2CnfgEntry 3}

prtExVc2Connect OBJECT-TYPE
      SYNTAX  INTEGER
              {
                no  (2),
                yes (3),
				v51 (4),
				v52 (5) 
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the  port  should be
       considered in any of the mux algorithms."
      ::= {prtVc2CnfgEntry 4}

prtExVc2TransGain OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Transmit gain in dBm.
       For ports of MP-104/204, MP-2100/2200  VC-6A, VC-6AG, VC-8
       VC-4/Omni and VC-16 cards, the units will be 0.1dBm because 
       valid values can be in 0.5dBm steps."
      ::= {prtVc2CnfgEntry 5}

prtExVc2ReceiveGain OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Receive gain in dBm.
       For ports of MP-104/204, MP-2100/2200  VC-6A, VC-6AG, VC-8
       VC-4/Omni and VC-16 cards, the units will be 0.1dBm because 
       valid values can be in 0.5dBm steps."
      ::= {prtVc2CnfgEntry 6}

prtExVc2Wire OBJECT-TYPE
      SYNTAX  INTEGER
       {
          w2wire   (1),
          w4wire   (2),
		  notApplicable  (255)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "For some cards, this object is equal for all the ports in the specific
       card because of HW limitations.
       For FXO & FXS this parameter is not applicable."
      ::= {prtVc2CnfgEntry 7}

prtExVc2CodingLaw OBJECT-TYPE
      SYNTAX  INTEGER
       {
          aLAW    (1),
          uLAW    (2)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Method/Law for decoding/encoding the voice
       information.
       aLaw(1) is the standard Law for E1 links.
       uLaw(2) is the standard Law for T1 links.

       This object is equal for all the ports in the specific module because
       of HW limitations"
      ::= {prtVc2CnfgEntry 8}

prtExVc2Sig OBJECT-TYPE
      SYNTAX  INTEGER
       {
          noSignaling           (1),
          robbedBitMultiFrame   (2),
          chAssociatedE1        (3),
          robbedBitFrame        (4)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the method for decoding/encoding the signaling
       information(on/off hook).
       noSignaling        (1) - not using signaling (only voice).
       robbedBitMultiFrame(2) - is the standard method for T1 links and
                                proprietary method for E1 links.
       chAssociatedE1     (3) - is valid only for E1 G.732S links.
       robbedBitFrame     (4) - is proprietary method implimenting 7 bit for
                                the voice and 1 bit dedicated for signaling.

       For some cards, this object is equal for all the ports in the specific module 
       because of HW limitations."
      ::= {prtVc2CnfgEntry 9}

prtExVc2Oos OBJECT-TYPE
      SYNTAX  INTEGER
       {
          forcedIdle     (1),
          forcedBusy     (2),
          busyIdle       (3),
          idleBusy       (4),
          notApplicable  (5)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object is equal for all the ports in the specific card
       because of HW limitations"
      ::= {prtVc2CnfgEntry 10}

prtExVc2LinkTo OBJECT-TYPE
      SYNTAX  INTEGER
       {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
	   notApplicable  (255)
       }
      MAX-ACCESS  read-write
      STATUS  deprecated
      DESCRIPTION
      "This attribute indicates the slot of the ML card to which
       the VC card is mapped.
       STATUS  deprecated - this object is replaced by prtGenCnfgLinkToSlot
       and prtGenCnfgLinkToPort."
      ::= {prtVc2CnfgEntry 11}

prtExVc2OperMode OBJECT-TYPE
      SYNTAX  INTEGER
       {
       normal          (2),
       unidirectRx     (3),
       broadcast       (4)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the operation mode of the port.
       normal = bi-directional (Tx/Rx)
       unidirectRx = unidirectional Rx.
       broadcast = Tx upon request."
      ::= {prtVc2CnfgEntry 12}


prtExVc2SigProfile OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable   (1),
       manual          (2),
       p1              (3),
       p2              (4),
       p3Fxo3S3        (5),
       reversePolarity (6),	 --3RP
       meteringPulse   (7),	 --3MP
	   p4              (8)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the Signaling Profile of the port.
       notApplicable - for VC-2 family and when
                       prtExVc2Sig=noSignaling(1)
       p1 = profile 1
       p2 = profile 2
       p3 = profile 3 
       p4 = profile 4 "
      ::= {prtVc2CnfgEntry 13}

prtExVc2CallEnable OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable (1),
       incoming      (2),
       outgoing      (3),
       both          (4)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the Enabled Call direction.
       notApplicable - for all cards except VC-2/R2.
       both     - incoming + outgoing."
      ::= {prtVc2CnfgEntry 14}

prtExVc2R2Delay OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable (1),
       terrestrial   (2),
       satellite     (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the R2 Delay.
       notApplicable - for all cards except VC-2/R2."
      ::= {prtVc2CnfgEntry 15}

prtExVc2CasStd OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable (1),
       r2Q422        (2),
       specialA      (3),
       specialB      (4),
	   specialC      (5),
	   specialD      (6),
	   specialE      (7),
   	   specialF      (8),
       specialG      (9)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the CAS (Channel Associated Signaling)
       Standard.
       notApplicable - for all cards except VC-2/R2."
      ::= {prtVc2CnfgEntry 16}

prtExVc2EchoCanceler OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable (1),
          off    (2),
          on     (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Echo canceler activation.
       notApplicable - for VC-2 and VC-6 cards."
      ::= {prtVc2CnfgEntry 17}

prtExVc2IfType OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable (1),
       w2Em     (2),
       w4Em     (3),
       fxo      (4),
       fxs      (5)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Interface Type."
      ::= {prtVc2CnfgEntry 18}

prtExVc2Encoding OBJECT-TYPE
      SYNTAX  INTEGER
       {
          notApplicable (1),
          pcm           (2),
          adpcm         (3),
		  linear        (4)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Voice Encoding Mode.
       linear - is relevant only for the ports of VC-16A card."
      ::= {prtVc2CnfgEntry 19}

prtExVc2TxBitCode OBJECT-TYPE
      SYNTAX  OCTET STRING
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "
       - - - For MP & FCD - - -

       This object represents 4 parameters, by 2 Octets :
       Tx D Bit Code-MSB nibble,
       Tx C Bit Code-    nibble,
       Tx B Bit Code-    nibble,
       Tx A Bit Code-LSB nibble.

       Each nibble:
    0 hex = 0000 = Not Applicable
    1 hex = 0001 = M lead
    2 hex = 0010 = M lead inverse
    3 hex = 0011 = Reverse Polarity
    4 hex = 0100 = Metering Pulse
    5 hex = 0101 = Forced 1
    6 hex = 0110 = Forced 0
    7-F hex - not used (invalid values)
       This object will be RO if prtExVc2SigProfile is NOT manual.
      
       
      - - - For WR II - - -

   This object represents the following 4 parameters by 2 Octets:
   1. On/Off hook signaling transmission mode from the FXS towards the T1/E1 (MSB nibble 1).
   2. Default signaling bits that are not in use (nibble 2).
   3. Ring Detection signaling transmission mode from the FXO towards the T1/E1(nibble 3).
   4. M (Mouth) Signaling transmission mode from the E&M towards the T1/E1(LSB nibble 4). 

      Each nibble:
	---------------------------------------------------------------------------------------
	Value          On/Off Hook       Default sig.      Ring Detect.        M (Mouth)
	---------------------------------------------------------------------------------------
    0 hex = 0000   Not Applicable    Not Applicable.  Not Applicable	   Not Applicable
    1 hex = 0001   Tx A bit			 Values 1-3 are	  Tx A bit			   Tx A bit
    2 hex = 0010   Tx A bit inverse	 for On/Off Hook  Tx A bit inv.	  	   Tx A bit inv.
    3 hex = 0011   Tx B bit			 A,B,A Inv,B Inv. Tx B bit			   Tx B bit
    4 hex = 0100   Tx B bit inverse	 Values 4-7 are	  Tx B bit inv.		   Tx B bit inv.
    5 hex = 0101   not Used-invalid	 for On/Off Hook  not Used-invalid	   not Used-invalid
    6 hex = 0110   not Used-invalid	 A, A Inverse.	  not Used-invalid 	   not Used-invalid
    7 hex = 0111   not Used-invalid			 		  not Used-invalid	   not Used-invalid	 
    8 hex = 1000   not Used-invalid	 Values 8-11 are  not Used-invalid	   not Used-invalid
    9 hex = 1001   not Used-invalid	 for On/Off Hook  not Used-invalid	   not Used-invalid
	A hex = 1010   not used-invalid	 B, B Inverse.	  not Used-invalid	   not Used-invalid
	B hex = 1011   not used-invalid	 The Bits order:  not Used-invalid	   not Used-invalid
    C-F hex 	   not used-invalid	 ABCD			  not Used-invalid	   not Used-invalid
   

    Default value: 11 11 "
      ::= {prtVc2CnfgEntry 20}

prtExVc2RxBitOutput OBJECT-TYPE
      SYNTAX  OCTET STRING
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "
       - - - For MP (VC-Q card only) & FCD - - -
       This object represents 3  parameters by 2 Octets:
       Spare       -MSB nibble, always=0 hex
       E Lead Output          -    nibble,
       Reverse Polarity Output-    nibble,
       Metering Pulse Output  -LSB nibble.

       Each nibble:
    0 hex = 0000 = Not Applicable
    1 hex = 0001 = Rx A bit
    2 hex = 0010 = Rx A bit inverse
    3 hex = 0011 = Rx B bit
    4 hex = 0100 = Rx B bit inverse
    5 hex = 0101 = Rx C bit
    6 hex = 0110 = Rx C bit inverse
    7 hex = 0111 = Rx D bit
    8 hex = 1000 = Rx D bit inverse
    9 hex = 1001 = none
    A-F hex - not used (invalid values)
       This object will be RO if prtExVc2SigProfile is NOT manual.

      - - - For MP (VC-8, VC-16, VC-16A cards) - - - 

    This object represents 4 parameters, by 2 Octets :
    Tx D Bit Code-MSB nibble,
    Tx C Bit Code-    nibble,
    Tx B Bit Code-    nibble,
    Tx A Bit Code-LSB nibble.

    Each nibble:
    0 hex = 0000 = Not Applicable
    1 hex = 0001 = not used (invalid value)
    2 hex = 0010 = not used (invalid value)
    3 hex = 0011 = not used (invalid value)
    4 hex = 0100 = not used (invalid value)
    5 hex = 0101 = Forced 1
    6 hex = 0110 = Forced 0
    7-F hex - not used (invalid values)
    This object will be RO.
       
             
      - - - For WR II - - -

   This object represents the following 2 parameters in 1 Octet:
   1. On/Off hook signaling receive mode from the T1/E1 into the FXS/FXO (MSB nibble 1).
   2. E (Ear) Signaling receive mode from the T1/E1 into the E&M (LSB nibble 2). 

      Each nibble:
	---------------------------------------------------------------------------------------
	Value          On/Off Hook       E (Ear)
	---------------------------------------------------------------------------------------
    0 hex = 0000   Not Applicable    Not Applicable
    1 hex = 0001   Rx A bit			 Rx A bit
    2 hex = 0010   Rx A bit inverse	 Rx A bit inverse
    3 hex = 0011   Rx B bit			 Rx B bit
    4 hex = 0100   Rx B bit inverse	 Rx B bit inverse
    5-F hex 	   not used-invalid	 not Used-invalid
   
	Default value: 11  "
      ::= {prtVc2CnfgEntry 21}

prtExVc2MeterRate OBJECT-TYPE
      SYNTAX  INTEGER
      {
        notApplicable(1),
        r16Khz  (2),
        r12Khz  (3),
		disabled(4)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This entry is applicable only for VC-6A/FXO, VC-6A/FXS, VC-8/FXO,
       VC-8/FXS, VC-16/FXO and VC-16/FXS.
       Meter Rate means rate of Call Meter in Public Phones, in KHz units.
       For some cards, the value must be the same for all card's ports."
      ::= {prtVc2CnfgEntry 22}

prtExVc2IfSignaling OBJECT-TYPE
      SYNTAX  INTEGER
      {
        notApplicable(1),
        loopStart    (2),
		groundStart  (3),
		winkStart    (4)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This entry is applicable only for VC-6A, VC-6AG, VC-8/FXO, VC-8/FXS,
       VC-16/FXO and VC-16/FXS cards.
       Interface Analog Signaling.
       Must be the same for all card's ports.
       loopStart - for the usual trunk/phone types.
       groundStart - for trunks that need Ground signaling .
       winkStart - for trunks that need Reverse Polarity. "
      ::= {prtVc2CnfgEntry 23}

prtExVc2SeizeAck OBJECT-TYPE
      SYNTAX INTEGER
      {
      notApplicable (1),
	  no  (2),
      yes (3)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This parameter shows whether the device will acknowledge
       a seize signal (On/Off Hook).
       When the value is set to yes(3) & the device receives an on/off hook signal
       it will transmit back an on/off hook signal.
	   When the value is set to no(2) & the device receives an on/off hook signal
       it will NOT transmit back an on/off hook signal.
       
       Default value for WR FXO: no(2)."
       ::= {prtVc2CnfgEntry 24}

prtExVc2EandMType OBJECT-TYPE
       SYNTAX INTEGER
	   {
       notApplicable (1),
	   type1 (2),
       type2 (3),
       type3 (4),
       type5 (5)  -- SSDC5  
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This is the signaling type on the E&M analog side.
       The analog signaling includes voltage, no. of pins and other parameters."
       ::= {prtVc2CnfgEntry 25}

prtExVc2RemType OBJECT-TYPE
       SYNTAX INTEGER
	   {
       notApplicable (1),
	   lb  (2),
       pbx (3),
	   e1  (4),
	   t1  (5),	 --T1ESF
	   t1D4  (6)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Remote Type.
       Applicable for VC-6A/4LB card &
       for IPMUX-1E Far End Type - E1,T1(T1-ESF) or T1-D4 ."
       ::= {prtVc2CnfgEntry 26}

prtExVc2ConvTime OBJECT-TYPE
       SYNTAX INTEGER
	   {
       notApplicable (1),
	   m2 (2),
       m3 (3),
	   m5 (4),
	   unlimited (5)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Conversation Time in minutes.
       Applicable for VC-6A/4LB card."
       ::= {prtVc2CnfgEntry 27}

prtExVc2SigFeedback OBJECT-TYPE
       SYNTAX INTEGER
	   {
       notApplicable (1),
	   no  (2),
       yes (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Signaling Feedback.
       Applicable for VC-8/FXO and VC-16/FXO cards."
       ::= {prtVc2CnfgEntry 28}

prtExVc2EchoCancelerModule OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable (1),
       notExist   (2),
       exist      (3)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This parameter indicates whether Echo canceler module exists for this port."
      ::= {prtVc2CnfgEntry 29}

prtExVc2ReversePolarity OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable (1),
       disabled      (2),
       enabled       (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object Enables/Disables Reverse Polarity for this port."
      ::= {prtVc2CnfgEntry 30}

prtExVc2RingerFrequency OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable (1),
       f20Hz         (2),
       f25Hz         (3),
	   f50Hz         (4)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object selects the Ringer Frequency (Hz) for this port."
      ::= {prtVc2CnfgEntry 31}

prtExVc2SigService OBJECT-TYPE
      SYNTAX  INTEGER
       {
          notApplicable (1),
          normal        (2),
          advanced      (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Signaling Service.
       advanced - is relevant only for ports of VC-8, VC-16 FXS cards.
       It is used for Signaling Services of V5.1 or R2."
      ::= {prtVc2CnfgEntry 32}

prtExVc2CallerIdEnable OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable (1),
       disabled      (2),
       enabled       (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object Enables/Disables Receiving the Caller Id number from the
       remote side, for this port/channel."
      ::= {prtVc2CnfgEntry 33}

prtExVc2CompressMethod OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable (1),
       g726          (2),
       g727          (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object is applicable only when prtExVc2Encoding=adpcm.
       It defines which method is used for Compression.
       g726 - for 4 bits (the standard method).
       g726 - for 3 bits. It is especially needed for T1 applications with signaling."
      ::= {prtVc2CnfgEntry 34}

prtExVc2ObMode OBJECT-TYPE
      SYNTAX  INTEGER
       {
       pointToPoint     (1),
       omniBus          (2),
       pointToMultiPointSrc(3),
	   pointToMultiPointDst(4)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object defines the Net operation mode of the Omni-Bus card's port.
       pointToPoint - only 2 end-point ports talk; like any other voice card
       omniBus      - many talk and listen. Like conference call. 
                      All can listen to all.
       pointToMultiPointSrc - There is one Master who can be heard by all. 
                      All can talk, but only the Master can hear all. Others can hear
                      only the Master. This port is of the Master (Src).
       pointToMultiPointDst - There is one Master who can be heard by all. 
                      All can talk, but only the Master can hear all. Others can hear
                      only the Master. This port is of a Destination (NOT Master)."             
      ::= {prtVc2CnfgEntry 35}

prtExVc2VAD OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable(1),
       off          (2),
       on           (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object defines whether Voice Activation Detector (VAD)
       will be On or Off.
	   off - will be usually selected when a Modem is connected
	         to the port; not a phone.
       notApplicable - when prtExVc2DspMode=pointToPoint."
      ::= {prtVc2CnfgEntry 36}

prtExVc2NoiseLevelForVAD OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable(1),
       low          (2),
       medium       (3),
	   high         (4) 
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object defines the Level of Noise on the line,
       the Voice Activation Detector (VAD) will have to deal with.
       notApplicable - when prtExVc2VAD=off."
      ::= {prtVc2CnfgEntry 37}

prtExVc2WesternSigMode OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable(1),
       detector     (2),
       generator    (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object defines the Western Signaling Mode.
	   detector - detects signal and passes it as is.
	   generator - generates the signal.
       notApplicable - when Western HW is not installed."
      ::= {prtVc2CnfgEntry 38}

prtExVc2BusProtectionPoint OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable(1),
       no     (2),
       first  (3),
	   last   (4)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object defines if the port is Bus Protection Point or not.
       notApplicable - when prtExVc2DspMode=pointToPoint.
       When we have a chain of devices where the edge devices ports are the 
       Bus Protection Point, user must configure one of these ports as 'first'
       and the other as 'last'. It does not matter which one, it just matters 
       that they will be different."
      ::= {prtVc2CnfgEntry 39}

prtExVc2ImpedanceStandard OBJECT-TYPE
      SYNTAX  INTEGER
       {
       g712     (1),
       q552ETSI (2),
       q522Italy(3)
        }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object defines the Standard used for Impedance.
       -G.712 - 600 Ohm - used in USA and other countries.
       -Q552/ETSI - used in some countries in Europe
       -Q522/Italy - used in Italy."
      ::= {prtVc2CnfgEntry 40}


--
-- Megaplex?000/?004 port specific config for HS(TDM) modules
-- HS-2,HS-3,HS-Q, HS-Q/SC, HS-6, HS-12
--
prtHsfCnfgTable OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtHsfCnfgEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
       "The write operation into the Table Objects is valid only
        to the TmpCnfg entry."
      ::= { cnfgPrtMux 6}

prtHsfCnfgEntry OBJECT-TYPE
      SYNTAX PrtHsfCnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtHsfCnfgIdx, prtHsfSltIdx, prtHsfPrtIdx }
      ::= { prtHsfCnfgTable 1}

PrtHsfCnfgEntry ::=
      SEQUENCE {
        prtHsfCnfgIdx       	Integer32,
        prtHsfSltIdx        	INTEGER,
        prtHsfPrtIdx        	INTEGER,
        prtExHsfConnect     	INTEGER,
        prtExHsfRate        	INTEGER,
        prtExHsfClkMode     	INTEGER,
        prtExHsfCts        	 	INTEGER,
        prtExHsfFifoSize    	INTEGER,
        prtExHsfLinkTo      	INTEGER,
  		prtExHsfOperMode    	INTEGER,
  		prtExHsfInbandLoopback 	INTEGER,
		prtExHsfClkPolarity     INTEGER,
		prtExHsfControlSignal   INTEGER,
		prtExHsfBcastRingSrcPort INTEGER
      }

prtHsfCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx  255 relate to the TmpCnfg. "
      ::= {prtHsfCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.

prtHsfSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
          {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted.
       In the ?004 Unit the entries io6(10)..io16) are not valid."
      ::= {prtHsfCnfgEntry 2}

prtHsfPrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
          {
         exPrt1    (1) ,
         exPrt2    (2) ,
         exPrt3    (3) ,
         exPrt4    (4) ,
         exPrt5    (5) ,
         exPrt6    (6) ,
         exPrt7    (7) ,
         exPrt8    (8) ,
         exPrt9    (9) ,
         exPrt10  (10) ,
         exPrt11  (11) ,
         exPrt12  (12) ,
		 inPrt1  (101) ,
		 inPrt2  (102)
          }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  external port index.
        Hs2 has only two ports (exPrt1,exPrt2).
        Hs3 has three ports (exPrt1,exPrt2,exPrt3).
        Hsq and hsqN has four ports.
        Hs6 has six external ports.
        Hs12 has twelve external ports.
        inPrt1, inPrt2 - are relevant for VID card."
      ::= {prtHsfCnfgEntry 3}

prtExHsfConnect OBJECT-TYPE
      SYNTAX  INTEGER
              {
                no  (2),
                yes (3)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the port should be
       considered in any of the mux algorithms."
      ::= {prtHsfCnfgEntry 4}

prtExHsfRate     OBJECT-TYPE
      SYNTAX  INTEGER
       {
        r1x56eq56Kbps    (1),
        r1x64eq64Kbps    (2),
        r2x56eq112Kbps   (3),
        r2x64eq128Kbps   (4),
        r3x56eq168Kbps   (5),
        r3x64eq192Kbps   (6),
        r4x56eq224Kbps   (7),
        r4x64eq256Kbps   (8),
        r5x56eq280Kbps   (9),
        r5x64eq320Kbps  (10),
        r6x56eq336Kbps  (11),
        r6x64eq384Kbps  (12),
        r7x56eq392Kbps  (13),
        r7x64eq448Kbps  (14),
        r8x56eq448Kbps  (15),
        r8x64eq512Kbps  (16),
        r9x56eq504Kbps  (17),
        r9x64eq576Kbps  (18),
        r10x56eq560Kbps (19),
        r10x64eq640Kbps (20),
        r11x56eq616Kbps (21),
        r11x64eq704Kbps (22),
        r12x56eq672Kbps (23),
        r12x64eq768Kbps (24),
        r13x56eq728Kbps (25),
        r13x64eq832Kbps (26),
        r14x56eq784Kbps (27),
        r14x64eq896Kbps (28),
        r15x56eq840Kbps (29),
        r15x64eq960Kbps (30),
        r16x56eq896Kbps (31),
        r16x64eq1024Kbps(32),
        r17x56eq952Kbps (33),
        r17x64eq1088Kbps(34),
        r18x56eq1008Kbps(35),
        r18x64eq1152Kbps(36),
        r19x56eq1064Kbps(37),
        r19x64eq1216Kbps(38),
        r20x56eq1120Kbps(39),
        r20x64eq1280Kbps(40),
        r21x56eq1176Kbps(41),
        r21x64eq1344Kbps(42),
        r22x56eq1232Kbps(43),
        r22x64eq1408Kbps(44),
        r23x56eq1288Kbps(45),
        r23x64eq1472Kbps(46),
        r24x56eq1344Kbps(47),
        r24x64eq1536Kbps(48),
        r25x56eq1400Kbps(49),
        r25x64eq1600Kbps(50),
        r26x56eq1456Kbps(51),
        r26x64eq1664Kbps(52),
        r27x56eq1512Kbps(53),
        r27x64eq1728Kbps(54),
        r28x56eq1568Kbps(55),
        r28x64eq1792Kbps(56),
        r29x56eq1624Kbps(57),
        r29x64eq1856Kbps(58),
        r30x56eq1680Kbps(59),
        r30x64eq1920Kbps(60),
        r31x56eq1736Kbps(61),
        r31x64eq1984Kbps(62),
        r32Kbps         (63)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the port speed. "
      ::= {prtHsfCnfgEntry 5}

prtExHsfClkMode OBJECT-TYPE
      SYNTAX  INTEGER
       {
          dce     (1),
          ext-dce (2),
          dte     (3),
          none    (4)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique port operation clock mode."
      ::= { prtHsfCnfgEntry 6}

prtExHsfCts OBJECT-TYPE
      SYNTAX  INTEGER
       {
     notApplicable (1),
     on            (2),
     rts           (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique CTS control line
       operation mode."
      ::= {prtHsfCnfgEntry 7}

prtExHsfFifoSize OBJECT-TYPE
      SYNTAX  INTEGER
       {
           auto     (2),
           s16bits  (3),
           s30bits  (4),
           s52bits  (5),
           s72bits  (6)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Size in bits."
      ::= {prtHsfCnfgEntry 8}

prtExHsfLinkTo  OBJECT-TYPE
      SYNTAX  INTEGER
       {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
       }
      MAX-ACCESS  read-write
      STATUS  deprecated
      DESCRIPTION
      "This attribute indicates a slot of Main Link module, that the
       port is linked to. This object is the same for all the
       ports in the specific card because of HW limitations.
       STATUS  deprecated - this object is replaced by prtGenCnfgLinkToSlot
       and prtGenCnfgLinkToPort."
      ::= {prtHsfCnfgEntry 9}

prtExHsfOperMode OBJECT-TYPE
      SYNTAX  INTEGER
       {
       normal          (2),
       unidirectRx     (3),
       broadcast       (4),
	   bidirBcastRing  (5)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the operation mode of the port.
       normal = bi-directional (Tx/Rx)
       unidirectRx = unidirectional Rx.
       broadcast = Tx upon request.
       bidirBcastRing = Bidirectional Broadcast Ring. When this value is selected,
                AND RTS=On, the port opens its transmission channel."
      ::= {prtHsfCnfgEntry 10}

prtExHsfInbandLoopback OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable   (1),
       disabled        (2),
       ft1Enabled      (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates if Inband Loopback from the Network
       should be enabled or disabled."
      ::= {prtHsfCnfgEntry 11}

prtExHsfClkPolarity OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable   (1),
       normal          (2),
       invert          (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the clock polarity.
       For FCD-M this object will be applicable only for the fixed HS port
       (the fixed port on the device)."
      ::= {prtHsfCnfgEntry 12}

prtExHsfControlSignal OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable   (1),
       local           (2),
       endToEnd        (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the Control Signal according to G.797 ITU-T standard.
       For FCD-M this object will be applicable for the fixed HS port
       (the fixed port on the device) and HS-Q/N channels.
       Local and End to End are applicable only when channel Interface type is RS-530, 
       else it will be Not Applicable."
      ::= {prtHsfCnfgEntry 13}

prtExHsfBcastRingSrcPort OBJECT-TYPE
      SYNTAX  INTEGER
          {
         exPrt1    (1) ,
         exPrt2    (2) ,
         exPrt3    (3) ,
         exPrt4    (4) ,
         exPrt5    (5) ,
         exPrt6    (6) ,
         exPrt7    (7) ,
         exPrt8    (8) ,
         exPrt9    (9) ,
         exPrt10  (10) ,
         exPrt11  (11) ,
         exPrt12  (12) ,
		 none    (100) , 
		 notApplicable  (255)
          }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object is applicable only when prtExHsfOperMode= 
       bidirBcastRing. In this case, the values mean:
       - none - this port will be connected to ML in TSA as usual.
       - exPrt1.. exPrtX ; X=maximum ports of the card in focus :
         it means that the same TS that is assigned in TSA to this port
         is actually connected also to this port, for Broadcast Ring mode.
         Therefore, this port should NOT be connected to ML in TSA."
      ::= {prtHsfCnfgEntry 14}

--
-- Megaplex?000/?004 Hs-4/1(HS4T1) HS-4/2(HS4E1) port configuration
--
--prtExHs4CnfgTable   OBJECT IDENTIFIER ::= {prtHs4Cnfg 1}
--prtExHs4TsCnfgTable OBJECT IDENTIFIER ::= {prtHs4Cnfg 2}

prtExHs4CnfgTable OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtExHs4CnfgEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
       "The write operation into the Table Objects is valid only
        to the TmpCnfg entry."
      ::= {prtHs4Cnfg 1}

prtExHs4CnfgEntry OBJECT-TYPE
      SYNTAX PrtExHs4CnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtExHs4CnfgIdx, prtExHs4SltIdx,  prtExHs4PrtIdx }
      ::= { prtExHs4CnfgTable 1}

PrtExHs4CnfgEntry ::=
      SEQUENCE {
        prtExHs4CnfgIdx     Integer32,
        prtExHs4SltIdx      INTEGER,
        prtExHs4PrtIdx      INTEGER,

     prtExHs4Connect     INTEGER,
     prtExHs4LineType    INTEGER,
     prtExHs4LineCode    INTEGER,
     prtExHs4LineLen     INTEGER,
     prtExHs4RestoreT    INTEGER,
     prtExHs4OosSig      INTEGER,
     prtExHs4OosCode     INTEGER,
     prtExHs4IdleCode    Integer32,
     prtExHs4MfClkSrcSlt INTEGER,
     prtExHs4MfClkSrcPrt INTEGER
      }

prtExHs4CnfgIdx OBJECT-TYPE
      SYNTAX  Integer32  (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx  255 relates to the TmpCnfg"
      ::= {prtExHs4CnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.

prtExHs4SltIdx OBJECT-TYPE
      SYNTAX  INTEGER
     {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted."
      ::= {prtExHs4CnfgEntry 2}

prtExHs4PrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
     {
       exPrt1    (1)
     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A unique identifier of the port, within the card."
      ::= {prtExHs4CnfgEntry 3}

prtExHs4Connect OBJECT-TYPE
      SYNTAX  INTEGER
       {
  no  (2),
  yes (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the port should be
       considered in any of the mux  algorithm. It also affects
       all the module considerations because the card has only
       one external (physical) interface."
      ::= {prtExHs4CnfgEntry 4}

prtExHs4LineType    OBJECT-TYPE
      SYNTAX  INTEGER
       {
  esfT1          (2), --> dsx1ESF
  sfT1           (3), --> dsx1D4
  g732nE1        (4), --> dsx1E1
  g732nE1CRC    (5), --> dsx1E1-CRC
  g732sE1        (6), --> dsx1E1-MF
  g732sE1CRC    (7)  --> dsx1E1-MF-CRC
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute is the line type parameter for T1/E1
       interface.
       The user should select only the parameters relevant to the
       specific card:
       T1 line code parameters for the HS-4/1 and
       E1 line code parameters for the HS-4/2.
       This parameter has the same values as dsx1LineType in T1/E1
       MIB (RFC-1406). The parameters in dsx1LineType are:
      other          (1)
      dsx1ESF        (2)
      dsx1D4         (3)
      dsx1E1         (4)
      dsx1E1-CRC     (5)
      dsx1E1-MF      (6)
      dsx1E1-MF-CRC  (7)"
      ::= {prtExHs4CnfgEntry 5}

prtExHs4LineCode OBJECT-TYPE
      SYNTAX  INTEGER
       {
  b7T1   (1),  --> dsx1JBZS
  b8zsT1 (2),  --> dsx1B8ZS
        hdb3E1 (4)   --> dsx1HDB3
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute is the line code parameter used for T1/E1
       interface.
       The user should select only the parameters relevant to the
       specific card:
       T1 line code parameters for the MPH.1/T1 and
       E1 line code parameters for the MPH.1/E1.
       This parameter has the same values as dsx1LineCoding in T1/E1
       MIB (RFC-1406).  The parameters in dsx1LineCoding are:
     dsx1JBZS  (1)
     dsx1B8ZS  (2)
     dsx1HDB3  (3)
     dsx1ZBTSI (4)
     dsx1AMI   (5)
     other     (6)"
      ::= {prtExHs4CnfgEntry 6}

prtExHs4LineLen  OBJECT-TYPE
      SYNTAX  INTEGER
       {
  unknown   (1),
        len0p133ft   (2),
        len134p266ft (3),
        len267p399ft (4),
        len400p533ft (5),
        len534p655ft (6),
        fcc68    (7)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute is the line length parameter used only for
       T1 interfaces.
       len399p533ft=len-399-533ft "
      ::= {prtExHs4CnfgEntry 7}

prtExHs4RestoreT OBJECT-TYPE
      SYNTAX  INTEGER
       {
        restoreT1secFast      (2),
        restoreT10sec62411    (3),
  ccittE1       (4)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Time passing from the disappearance of the loss of
       synchronization condition (red alarm), to the restoration
       of normal service."
      ::= {prtExHs4CnfgEntry 8}

prtExHs4OosSig   OBJECT-TYPE
      SYNTAX  INTEGER
       {
        notsupported  (2),
        forcedIdle    (3),
        forcedBusy    (4),
        busyIdle      (5),
        idleBusy      (6)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Out of Service signal type."
      ::= {prtExHs4CnfgEntry 9}

prtExHs4OosCode  OBJECT-TYPE
      SYNTAX  INTEGER
          {
          notsupported (2),
            oosCode00H        (3),
            oosCode1aH        (4),
            oosCode54H        (5),
            oosCode7eH        (6),
            oosCode7fH        (7),
            oosCode98H        (8),
            oosCode9eH        (9),
            oosCoded5H        (10),
            oosCodee4H        (11),
            oosCodeffH        (12)
          }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "OOS Code"
      ::= {prtExHs4CnfgEntry 10}

prtExHs4IdleCode  OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      " Type value(00 - FF HEX), excluding 0H,8H,10H,12H,21H,24H,
        42H,49H,84H,92H"
      ::= {prtExHs4CnfgEntry 11}

prtExHs4MfClkSrcSlt  OBJECT-TYPE
      SYNTAX  INTEGER
       {
          local (2),
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
"This attribute indicates whether the port Tx is multiframe
synchronized with Rx multiframe of another port and the slot position of that port.
This opration is required in order to bypass signaling of PCM
voice channels.
When its value is Local(2) there is no meaning to 'prtExHs4MfClkSrcPrt'
parameter.
In the ?004 Unit the entries io6(10)..io16) are not valid"
      ::= {prtExHs4CnfgEntry 12}

prtExHs4MfClkSrcPrt  OBJECT-TYPE
      SYNTAX  INTEGER
      {
       exPrt1    (1),
       exPrt2    (2),
       inPrt1  (101)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "A unique number to identify a port position in the mux if the
       MultiFrame clock source is valid (YES).
       inPrt1 - for MTML-H/E1 cards."
      ::= {prtExHs4CnfgEntry 13}

--
-- Hs4 Time Slot Config Table
--
prtExHs4TsCnfgTable OBJECT-TYPE
     SYNTAX SEQUENCE OF PrtExHs4TsEntry
     MAX-ACCESS not-accessible
     STATUS  current
     DESCRIPTION
      "The write operation into the Table Objects is valid only
       to the TmpCnfg entry."
     ::= {prtHs4Cnfg 2}

prtExHs4TsEntry OBJECT-TYPE
      SYNTAX PrtExHs4TsEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtExHs4TsCnfgIdx, prtExHs4TsSltIdx, prtExHs4TsPrtIdx, prtExHs4TsIdx }
      ::= { prtExHs4TsCnfgTable 1}

PrtExHs4TsEntry ::=
      SEQUENCE {
      prtExHs4TsCnfgIdx        Integer32,
      prtExHs4TsSltIdx         INTEGER,
      prtExHs4TsPrtIdx         INTEGER,
      prtExHs4TsIdx            Integer32,
      prtExHs4TsIConSlot       INTEGER,
      prtExHs4TsIConPrt        INTEGER,
      prtExHs4TsIConTs         Integer32 
	}

prtExHs4TsCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32  (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg. "
      ::= { prtExHs4TsEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.

prtExHs4TsSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
     {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted.
       In the ?004 Unit the entries io6(10)..io16) are not valid"
      ::= { prtExHs4TsEntry 2}

prtExHs4TsPrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
 {
          exPrt1    (1)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  port number.
       Hs4/T1 and Hs4/T1 cards have only one external interface."
      ::= { prtExHs4TsEntry 3}

prtExHs4TsIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique time slot  position.
       The valid time slots are:
       1..24 for T1 Card and
       1..31 for E1 interface.
       In G732S-E1 lines, time slot 16 is not valid for data,
       it is dedicated to multiframe synchronization bits
       and voice signaling."
      ::= { prtExHs4TsEntry 4}

prtExHs4TsIConSlot OBJECT-TYPE
      SYNTAX  INTEGER
       {
       noConnect (2),
          io1       (5),
          io2       (6),
          io3       (7),
          io4       (8),
          io5       (9),
          io6      (10),
          io7      (11),
          io8      (12),
          io9      (13),
          io10     (14),
          io11     (15),
          io12     (16),
    split   (100)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the specified time slot is
       connected/routed internally in the Agent and to which card
       it is connected.
       In the ?004 Unit the entries io6(10)..io16) are not valid.
    split - will be used when the Src TS is connected to more
               than one slot OR more than one port (each needing
               less than a whole TS)."
      ::= {prtExHs4TsEntry 5}

prtExHs4TsIConPrt OBJECT-TYPE
      SYNTAX  INTEGER
       {
       exPrt1    (1) ,
       exPrt2    (2) ,
       exPrt3    (3) ,
       exPrt4    (4) ,
       exPrt5    (5) ,
       exPrt6    (6) ,
       exPrt7    (7) ,
       exPrt8    (8) ,
       exPrt9    (9) ,
       exPrt10  (10) ,
       exPrt11  (11) ,
       exPrt12  (12) ,
       noConnect (100)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the internally (In Mux)
       connected/routed port."
      ::= {prtExHs4TsEntry 6}

prtExHs4TsIConTs OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique time slot  position.
       The valid time slots are:
       1..24 for T1 Module and
       1..31 for E1 interface.
       In G732S-E1 lines time slot 16 is not valid for data,
       it is dedicated for multiframe synchronization bits
       and voice signaling."
      ::= { prtExHs4TsEntry 7}

--
-- Megaplex?000/?004 and DXC Hs-U port configuration
--
--prtExHsiCnfgTable   OBJECT IDENTIFIER ::= {prtHsiCnfg 1}

prtExHsiCnfgTable OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtExHsiCnfgEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
       "The write operation into the Table Objects is valid only
        to the TmpCnfg entry."
      ::= {prtHsiCnfg 1}

prtExHsiCnfgEntry OBJECT-TYPE
      SYNTAX PrtExHsiCnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtExHsiCnfgIdx, prtExHsiSltIdx,  prtExHsiPrtIdx }
      ::= { prtExHsiCnfgTable 1}

PrtExHsiCnfgEntry ::=
      SEQUENCE {
        prtExHsiCnfgIdx     Integer32,
        prtExHsiSltIdx      INTEGER,
        prtExHsiPrtIdx      Integer32,

        prtExHsiConnect     INTEGER,
        prtExHsiRate        INTEGER,
        prtExHsiLinkTo      INTEGER,
        prtExHsiInterface   INTEGER,
		prtExHsiActType		INTEGER
      }

prtExHsiCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32  (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg"
      ::= {prtExHsiCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.

prtExHsiSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
     {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
	   io13 (17),
	   io14 (18),
	   io15 (19),
	   notApplicable (255)
     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted."
      ::= {prtExHsiCnfgEntry 2}

prtExHsiPrtIdx OBJECT-TYPE
      SYNTAX  Integer32
--     {
--          exPrt1    (1),
--          exPrt2    (2),
--          exPrt3    (3),
--          exPrt4    (4),
--          exPrt5    (5),
--          exPrt6    (6),
--          exPrt7    (7),
--          exPrt8    (8),
--          exPrt9    (9),
--          exPrt10  (10),
--          exPrt11  (11),
--          exPrt12  (12)
--        }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A unique port identifier within the card.
       For MP : 1..12
       For DXC: 111 .. 2531. See DXC R6 spec for port index convention.
       For FCD-A, 'S' Interface external ports: 131, 141, 151, 161."
      ::= {prtExHsiCnfgEntry 3}

prtExHsiConnect OBJECT-TYPE
      SYNTAX  INTEGER
       {
        no  (2),
        yes (3),
		v51 (4),
		v52 (5)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the port should be considered in
       any of the mux  algorithms.
       v51 - this port is connected to a V5.1 interface. All rest of the
             values will be 'notApplicable' in this case. V5 MIB will be
             used instead.
       v52 - this port is connected to a V5.2 interface. All rest of the
             values will be 'notApplicable' in this case. V5 MIB will be
             used instead."
      ::= {prtExHsiCnfgEntry 4}

prtExHsiRate    OBJECT-TYPE
      SYNTAX  INTEGER
       {
          r600bps   (2),
          r1200bps  (3),
          r2400bps  (4),
          r4800bps  (5),
          r9600bps  (6),
          r19200bps (7),
          r38400bps (8),
          r48kbps   (9),
          r56kbps  (10),
          r64kbps  (11),
          r128kbps (12),
    notApplicable (255)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the port speed."
      ::= {prtExHsiCnfgEntry 5}

prtExHsiLinkTo  OBJECT-TYPE
      SYNTAX  INTEGER
       {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
       }
      MAX-ACCESS  read-write
      STATUS  deprecated
      DESCRIPTION
      "It indicates the slot of the main link card to which the HS-? card
       is mapped.
       STATUS  deprecated - this object is replaced by prtGenCnfgLinkToSlot
       and prtGenCnfgLinkToPort."
      ::= {prtExHsiCnfgEntry 6}

prtExHsiInterface  OBJECT-TYPE
      SYNTAX  INTEGER
       {
       lt   (1),
       nt   (2),
       te   (3),
	   lt1  (4),
    notApplicable (255)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "It indicates the interface type:
       lt = line termination
       nt = network termination
       te = terminal equipment.
	   lt1 - for ASMi-31 connection (not ISDN)
	   For MP:
       For HS-U/I only 'lt' and 'nt' are applicable.
	   For HS-U/1 only 'lt' is applicable.
       For HS-S , only 'te' and 'nt' are applicable.
       For HS-U, this object is not applicable.
       For HS-U6, HS-U12, are applicable: 'lt'=lt-i,'nt'=nt-i, lt1.
       For DXC:
       For HS-U8, HS-U16, are applicable: 'lt'=LT-I,'nt'=NT-I, 'lt1'=LT-1."
      ::= {prtExHsiCnfgEntry 7}

prtExHsiActType  OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable (1),
       type1 (2),
       type2 (3),
	   type3 (4)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "It indicates the Activation Type. Activation Type is the Synchronization
	   type towards the PBX. It is applicable only when prtExHsiInterface=nt.
	   notApplicable - for cards that do not support this object, or when 
	   prtExHsiInterface is NOT nt."
      ::= {prtExHsiCnfgEntry 8}


--prtInHsiCnfgTable   OBJECT IDENTIFIER ::= {prtHsiCnfg 2}
--This table is not applicable for MP-2100 HS-U card type

prtInHsiCnfgTable OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtInHsiCnfgEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
       "The write operation into the Table Objects is valid only
        to the TmpCnfg entry.
        This table is not applicable for MP-2100 HS-U card type."
      ::= {prtHsiCnfg 2}

prtInHsiCnfgEntry OBJECT-TYPE
      SYNTAX PrtInHsiCnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtInHsiCnfgIdx, prtInHsiSltIdx,  prtInHsiPrtIdx }
      ::= { prtInHsiCnfgTable 1}

PrtInHsiCnfgEntry ::=
      SEQUENCE {
        prtInHsiCnfgIdx     Integer32,
        prtInHsiSltIdx      INTEGER,
        prtInHsiPrtIdx      Integer32,

        prtInHsiConnect     INTEGER,
        prtInHsiRate        INTEGER,
		prtInHsiConcentratedTo Integer32 
	}

prtInHsiCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32  (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg"
      ::= {prtInHsiCnfgEntry 1}

prtInHsiSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
     {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
	   io13 (17),
	   io14 (18),
	   io15 (19),
	   notApplicable (255)
     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates a unique  slot  position where
       the card is inserted."
      ::= {prtInHsiCnfgEntry 2}

prtInHsiPrtIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A unique port identifier within the card.
       Valid values for MP: inPrt1 (101) .. inPrt48 (148).
       Valid values for DXC: 11012.. 25316. See DXC R6 spec for port index convention."
      ::= {prtInHsiCnfgEntry 3}

prtInHsiConnect OBJECT-TYPE
      SYNTAX  INTEGER
       {
       no  (2),
       yes (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the port should be considered in
       any of the mux  algorithms."
      ::= {prtInHsiCnfgEntry 4}

prtInHsiRate    OBJECT-TYPE
      SYNTAX  INTEGER
       {
          r600bps   (2),
          r1200bps  (3),
          r2400bps  (4),
          r4800bps  (5),
          r9600bps  (6),
          r19200bps (7),
          r38400bps (8),
          r48kbps   (9),
          r56kbps  (10),
          r64kbps  (11),
          r128kbps (12),
		  concentrated  (13),
		  notConnected (100),  
          notApplicable(255)
          }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the port speed.
       For HS-U/I and HS-S ports:
       2 bit - up to 9600bps
       4 bit - 19200bps
       8 bit - 38400bps .. 64kbps.
       concentrated - this D channel goes to a Concentration channel,
                      that represents many channels that this value was
                      selected for them. The Concentrated channel is an
                      Internal D Channel of the same card. 
                      This value is applicable only for	D channels, except 
                      Concentration channel itself.
                      --for HS-S and HS-U/I cards the Concentration channel 
                        will always be: internal-13
                      --for MP-2200 HS-S12, HS-S6, HS-U12, HS-U6 and
                        DXC HS-U8 and HS-U16 cards, the Concentration channel
                        is selected via the prtInHsiConcentratedTo object.
       notConnected - same as prtInHsiConnect=no."
      ::= {prtInHsiCnfgEntry 5}

prtInHsiConcentratedTo OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The Concentration D Channel of the prtInHsiPrtIdx port.
	   The port always belongs to the same card as prtInHsiPrtIdx port.
	   This object is applicable only when prtInHsiRate=concentrated.
       Valid values:
	   - notApplicable: 255
       - for MP-2200: HS-S12, HS-U12 cards: inPrt37 (137) .. inPrt48 (148).
                      HS-S6, HS-U6 cards: inPrt19 (119) .. inPrt24 (124).
       - for DXC:     HS-U8  cards: 112 .. 254
                      HS-U16 cards: 112 .. 258. See DXC R6 spec for port index 
                      convention."
      ::= {prtInHsiCnfgEntry 6}

--
-- Megaplex?000/?004 Hs-R and HS-U port configuration
-- DXC HS-U8, HS-U16 port configuration for Interface=LT-1
--
--prtExHsrCnfgTable   OBJECT IDENTIFIER ::= {prtHsrCnfg 1}

prtExHsrCnfgTable OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtExHsrCnfgEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
       "The write operation into the Table Objects is valid only
        to the TmpCnfg entry."
      ::= {prtHsrCnfg 1}

prtExHsrCnfgEntry OBJECT-TYPE
      SYNTAX PrtExHsrCnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtExHsrCnfgIdx, prtExHsrSltIdx,  prtExHsrPrtIdx }
      ::= { prtExHsrCnfgTable 1}

PrtExHsrCnfgEntry ::=
      SEQUENCE {
        prtExHsrCnfgIdx     Integer32,
        prtExHsrSltIdx      INTEGER,
        prtExHsrPrtIdx      Integer32,

        prtExHsrConnect     INTEGER,
        prtExHsrProtocol    INTEGER,
        prtExHsrRate        INTEGER,
        prtExHsrDataBits    INTEGER,
        prtExHsrParity      INTEGER,
        prtExHsrStopBits    INTEGER,
        prtExHsrCts         INTEGER,
        prtExHsrClkMode     INTEGER,
        prtExHsrLinkTo      INTEGER,
        prtExHsrDcdDsr      INTEGER,
        prtExHsrOperMode    INTEGER,
        prtExHsrRtsDtr      INTEGER,
		prtExHsrLlbEnable   INTEGER,
		prtExHsrRlbEnable   INTEGER,
		prtExHsrRateAdapt   INTEGER,
		prtExHsrRemoteModem INTEGER ,
		prtExHsrEncapsMode  INTEGER
      }

prtExHsrCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32  (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg"
      ::= {prtExHsrCnfgEntry 1}

prtExHsrSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
     {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
	   io13 (17),
	   io14 (18),
	   io15 (19)
     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates a unique  slot  position where
       the card is inserted."
      ::= {prtExHsrCnfgEntry 2}

prtExHsrPrtIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A unique prt identifier within the card.
       Valid values:
	   For MP:
        - For HS-R cards: exPrt1 (1)   .. exPrt4 (4)
        - For HS-U/1 cards: inPrt1 (101) .. inPrt4 (104)
        - For HS-S12, HS-S6, HS-U12, HS-U6 cards:
          exPrt1 (1) .. exPrt12 (12). 
          This MIB table is used only for LT-1 interface.
       For DXC:
        - For HS-U8, HS-U16 cards:
          111 .. 2531 (See DXC R6 spec for port index convention). 
          This MIB table is used only for LT-1 interface."
      ::= {prtExHsrCnfgEntry 3}

prtExHsrConnect OBJECT-TYPE
      SYNTAX  INTEGER
       {
       no  (2),
       yes (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates whether the port should be considered in
       any of the mux  algorithms."
      ::= {prtExHsrCnfgEntry 4}

prtExHsrProtocol OBJECT-TYPE
      SYNTAX  INTEGER
              {
                sync  (2),
                async (3)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the protocol."
      ::= {prtExHsrCnfgEntry 5}

prtExHsrRate    OBJECT-TYPE
      SYNTAX  INTEGER
       {
       r600bps    (2),
       r1200bps   (3),
       r2400bps   (4),
       r4800bps   (5),
       r9600bps   (6),
       r19200bps  (7),
       r38400bps  (8),
       r48kbps    (9),
       r56kbps   (10),
       r64kbps   (11),
       r16000bps (12),
       r32000bps (13),
       r57600bps (14),
       r115200bps(15),
       r128000bps(16),
	   r7200bps  (17),
	   r14400bps (18),
	   r28800bps (19),
	   notConnected (100)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the port speed.
       The 16,32,48,56,64 and 128 kbps rates are applicable only for Sync
       protocol.
       The 57.6 and 115.2 kbps rates are applicable only for Async
       protocol.
       notConnected= 0 rate."
      ::= {prtExHsrCnfgEntry 6}

prtExHsrDataBits OBJECT-TYPE
      SYNTAX  INTEGER
       {
        d5bits    (1),
        d6bits    (2),
        d7bits    (3),
        d8bits    (4),
        notApplicable (255)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Data Bits.
       This object is applicable for Async protocol only."
      ::= {prtExHsrCnfgEntry 7}

prtExHsrParity OBJECT-TYPE
      SYNTAX  INTEGER
       {
        no  (2),
        yes (3),
		odd (4),
		even(5),
        notApplicable (255)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "- For HS-R card, this object indicates if the parity bit is needed or not.
	     Therefore, the 'no' and 'yes; values are applicable. 
       - For HS-S12, HS-U12, the parity type is selected: no, odd, even.
       This object is applicable for Async protocol only."
      ::= { prtExHsrCnfgEntry 8}

prtExHsrStopBits OBJECT-TYPE
      SYNTAX  INTEGER
       {
        stopBits1Bit      (1),
        stopBits2Bits     (2),
        notApplicable   (255)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the minimum number of stop bits in
       the tx async frame.
       This object is applicable for Async protocol only."
      ::= { prtExHsrCnfgEntry 9}

prtExHsrCts OBJECT-TYPE
      SYNTAX  INTEGER
       {
       on       (2),
       rts      (3),
       notApplicable   (255)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "CTS.
       This object is applicable for Async protocol only."
      ::= {prtExHsrCnfgEntry 10}

prtExHsrClkMode OBJECT-TYPE
      SYNTAX  INTEGER
      {
      dce     (1),
      extDce  (2),
      notApplicable  (255)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Clock mode.
       This object is applicable for Sync protocol only."
      ::= { prtExHsrCnfgEntry 11}

prtExHsrLinkTo  OBJECT-TYPE
      SYNTAX  INTEGER
       {
	   notApplicable (1),
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
       }
      MAX-ACCESS  read-write
      STATUS  deprecated
      DESCRIPTION
      "It indicates the slot of the main link card to which the HS-R card
       is mapped.
       notApplicable - for HS-U/1 internal ports.
       STATUS  deprecated - this object is replaced by prtGenCnfgLinkToSlot
       and prtGenCnfgLinkToPort."
      ::= {prtExHsrCnfgEntry 12}

prtExHsrDcdDsr OBJECT-TYPE
      SYNTAX  INTEGER
       {
        notApplicable (1),
        local         (2),
        endToEnd      (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "DCD & DSR."
      ::= {prtExHsrCnfgEntry 13}


prtExHsrOperMode OBJECT-TYPE
      SYNTAX  INTEGER
       {
       normal          (2),
       unidirectRx     (3),
       broadcast       (4)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the operation mode of the port.
       normal = bi-directional (Tx/Rx)
       unidirectRx = unidirectional Rx.
       broadcast = Tx upon request."
      ::= {prtExHsrCnfgEntry 14}

prtExHsrRtsDtr OBJECT-TYPE
      SYNTAX  INTEGER
       {
        notApplicable (1),
        local         (2),
        endToEnd      (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "RTS & DTR."
      ::= {prtExHsrCnfgEntry 15}

prtExHsrLlbEnable OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable (1),
       disabled      (2),
       enabled       (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Enable/Disable LLB."
      ::= {prtExHsrCnfgEntry 16}

prtExHsrRlbEnable OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable (1),
       disabled      (2),
       enabled       (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Enable/Disable RLB."
      ::= {prtExHsrCnfgEntry 17}

prtExHsrRateAdapt OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable (1),
       proprietary   (2),
       v110          (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Rate Adaptation - takes a low rate and adapts it to 64Kbps.
       This object specifies the means this adaptation is done by."
      ::= {prtExHsrCnfgEntry 18}

prtExHsrRemoteModem OBJECT-TYPE
      SYNTAX  INTEGER
       {
    notApplicable (1),
    asmi31        (2),
    asmi31s2      (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Remote modem.
       asmi31s2 = ASMi-31/2 "
      ::= {prtExHsrCnfgEntry 19}

prtExHsrEncapsMode OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable    (1),
       bwOptimized      (2),
	   latencyOptimized (3),
       asmi31           (4)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Low Speed encapsulation method over PCM.

       When Encapsulation mode is Latency optimized, only rates up to 19.2 are supported.
       In this case a double number of bits occupy the Time Slot.
       For up to 9.6 Kbps   - 4 bits are occupied.
       For 14.4 & 19.2 Kbps - 8 bits are occupied.
       
       When Encapsulation Mode is Bandwidth Optimized:
       For up to 9.6 Kbps   - 2 bits are occupied.
       For 14.4 & 19.2 Kbps - 4 bits are occupied.
       For higher rates - 8 bits are occupied."
      ::= {prtExHsrCnfgEntry 20}

--
-- Megaplex?000/?004 MBE port configuration
--

prtExMbeCnfgTable OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtExMbeCnfgEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
       "The write operation into the Table Objects is valid only
        to the TmpCnfg entry."
      ::= {prtMbeCnfg 1}

prtExMbeCnfgEntry OBJECT-TYPE
      SYNTAX PrtExMbeCnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtExMbeCnfgIdx, prtExMbeSltIdx,  prtExMbePrtIdx }
      ::= { prtExMbeCnfgTable 1}

PrtExMbeCnfgEntry ::=
      SEQUENCE {
        prtExMbeCnfgIdx     Integer32,
        prtExMbeSltIdx      INTEGER,
        prtExMbePrtIdx      INTEGER,

        prtExMbeLan         INTEGER
      }

prtExMbeCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32  (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg"
      ::= {prtExMbeCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.

prtExMbeSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
     {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted.
       In the ?004 Unit the entries io6(10)..io16) are not valid."
      ::= {prtExMbeCnfgEntry 2}

prtExMbePrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
     {
          exPrt1    (1)
     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A unique port identifier within the card."
      ::= {prtExMbeCnfgEntry 3}

prtExMbeLan OBJECT-TYPE
      SYNTAX  INTEGER
       {
        remote  (1),
        main    (2)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the MBE port is operated
       as main or remote bridge."
      ::= {prtExMbeCnfgEntry 4}

prtInMbeCnfgTable OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtInMbeCnfgEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
       "The write operation into the Table Objects is valid only
        to the TmpCnfg entry."
      ::= {prtMbeCnfg 2}

prtInMbeCnfgEntry OBJECT-TYPE
      SYNTAX PrtInMbeCnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtInMbeCnfgIdx, prtInMbeSltIdx,  prtInMbePrtIdx }
      ::= { prtInMbeCnfgTable 1}

PrtInMbeCnfgEntry ::=
      SEQUENCE {
        prtInMbeCnfgIdx     Integer32,
        prtInMbeSltIdx      INTEGER,
        prtInMbePrtIdx      INTEGER,

        prtInMbeConnect     INTEGER,
        prtInMbeRate        INTEGER,
        prtInMbeLinkTo      INTEGER
      }

prtInMbeCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32  (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg"
      ::= {prtInMbeCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.

prtInMbeSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
     {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted.
       In the ?004 Unit the entries io6(10)..io16) are not valid."
      ::= {prtInMbeCnfgEntry 2}

prtInMbePrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
     {
          inPrt1    (101)
     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A unique port identifier within the card."
      ::= {prtInMbeCnfgEntry 3}

prtInMbeConnect OBJECT-TYPE
      SYNTAX  INTEGER
       {
  no  (2),
  yes (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the port should be considered in
       any of the mux  algorithms."
      ::= {prtInMbeCnfgEntry 4}

prtInMbeRate    OBJECT-TYPE
      SYNTAX  INTEGER
	      {
        r1x64eq64Kbps    (1),
        r2x64eq128Kbps   (2),
        r3x64eq192Kbps   (3),
        r4x64eq256Kbps   (4),
        r5x64eq320Kbps   (5),
        r6x64eq384Kbps   (6),
        r7x64eq448Kbps   (7),
        r8x64eq512Kbps   (8),
        r9x64eq576Kbps   (9),
        r10x64eq640Kbps (10),
        r11x64eq704Kbps (11),
        r12x64eq768Kbps (12),
        r13x64eq832Kbps (13),
        r14x64eq896Kbps (14),
        r15x64eq960Kbps (15),
        r16x64eq1024Kbps(16),
        r17x64eq1088Kbps(17),
        r18x64eq1152Kbps(18),
        r19x64eq1216Kbps(19),
        r20x64eq1280Kbps(20),
        r21x64eq1344Kbps(21),
        r22x64eq1408Kbps(22),
        r23x64eq1472Kbps(23),
        r24x64eq1536Kbps(24)
	      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the port speed."
      ::= {prtInMbeCnfgEntry 5}

prtInMbeLinkTo  OBJECT-TYPE
      SYNTAX  INTEGER
       {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
       }
      MAX-ACCESS  read-write
      STATUS  deprecated
      DESCRIPTION
      "It indicates the slot of the main link card to which the
       MBE card is mapped.
       In the ?004 Unit the entries io6(10)..io16) are not valid.
       STATUS  deprecated - this object is replaced by prtGenCnfgLinkToSlot
       and prtGenCnfgLinkToPort."
      ::= {prtInMbeCnfgEntry 6}


--
-- Megaplex?000/?004 TRE port configuration
--

prtExTreCnfgTable OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtExTreCnfgEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
       "The write operation into the Table Objects is valid only
        to the TmpCnfg entry."
      ::= {prtTreCnfg 1}

prtExTreCnfgEntry OBJECT-TYPE
      SYNTAX PrtExTreCnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtExTreCnfgIdx, prtExTreSltIdx,  prtExTrePrtIdx }
      ::= { prtExTreCnfgTable 1}

PrtExTreCnfgEntry ::=
      SEQUENCE {
        prtExTreCnfgIdx     Integer32,
        prtExTreSltIdx      INTEGER,
        prtExTrePrtIdx      INTEGER,

        prtExTreLan         INTEGER,
        prtExTreLanRate     INTEGER

      }

prtExTreCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32  (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg"
      ::= {prtExTreCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.

prtExTreSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
     {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted.
       In the ?004 Unit the entries io6(10)..io16) are not valid."
      ::= {prtExTreCnfgEntry 2}

prtExTrePrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
     {
          exPrt1    (1)
     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A unique port identifier within the card."
      ::= {prtExTreCnfgEntry 3}

prtExTreLan OBJECT-TYPE
      SYNTAX  INTEGER
       {
        remote  (1),
        main    (2)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the TRE port is operated
       as main or remote bridge.
       Default=remote."
      ::= {prtExTreCnfgEntry 4}

prtExTreLanRate OBJECT-TYPE
      SYNTAX  INTEGER
       {
        r4M  (1),
        r16M (2)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Rate of the TRE port
       in Mbit/sec.
       Default-r4M."
      ::= {prtExTreCnfgEntry 5}



prtInTreCnfgTable OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtInTreCnfgEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
       "The write operation into the Table Objects is valid only
        to the TmpCnfg entry."
      ::= {prtTreCnfg 2}

prtInTreCnfgEntry OBJECT-TYPE
      SYNTAX PrtInTreCnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtInTreCnfgIdx, prtInTreSltIdx,  prtInTrePrtIdx }
      ::= { prtInTreCnfgTable 1}

PrtInTreCnfgEntry ::=
      SEQUENCE {
        prtInTreCnfgIdx     Integer32,
        prtInTreSltIdx      INTEGER,
        prtInTrePrtIdx      INTEGER,

        prtInTreConnect     INTEGER,
        prtInTreRate        INTEGER,
        prtInTreLinkTo      INTEGER
      }

prtInTreCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32  (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg"
      ::= {prtInTreCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.

prtInTreSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
     {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted.
       In the ?004 Unit the entries io6(10)..io16) are not valid."
      ::= {prtInTreCnfgEntry 2}

prtInTrePrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
     {
          inPrt1    (101)
     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A unique port identifier within the card."
      ::= {prtInTreCnfgEntry 3}

prtInTreConnect OBJECT-TYPE
      SYNTAX  INTEGER
       {
  no  (2),
  yes (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the port should be considered
       in any of the mux  algorithms."
      ::= {prtInTreCnfgEntry 4}

prtInTreRate    OBJECT-TYPE
      SYNTAX  INTEGER
       {
        r1x56eq56Kbps    (1),
        r1x64eq64Kbps    (2),
        r2x56eq112Kbps   (3),
        r2x64eq128Kbps   (4),
        r3x56eq168Kbps   (5),
        r3x64eq192Kbps   (6),
        r4x56eq224Kbps   (7),
        r4x64eq256Kbps   (8),
        r5x56eq280Kbps   (9),
        r5x64eq320Kbps   (10),
        r6x56eq336Kbps   (11),
        r6x64eq384Kbps   (12),
        r7x56eq392Kbps   (13),
        r7x64eq448Kbps   (14),
        r8x56eq448Kbps   (15),
        r8x64eq512Kbps   (16),
        r9x56eq504Kbps   (17)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the port speed."
      ::= {prtInTreCnfgEntry 5}

prtInTreLinkTo  OBJECT-TYPE
      SYNTAX  INTEGER
       {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
       }
      MAX-ACCESS  read-write
      STATUS  deprecated
      DESCRIPTION
      "It indicates the slot of the main link card to which the
       MBE card is mapped.
       In the ?004 Unit the entries io6(10)..io16) are not valid.
       STATUS  deprecated - this object is replaced by prtGenCnfgLinkToSlot
       and prtGenCnfgLinkToPort."
      ::= {prtInTreCnfgEntry 6}


-- Packet VC cards. 
-- This table is used for compressed voice cards with 4/8 ports.
--

prtExPVc4CnfgTable OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtExPVc4CnfgEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
       "The write operation into the Table Objects is valid only
        to the TmpCnfg entry."
      ::= { prtPVc4Cnfg 1}

prtExPVc4CnfgEntry OBJECT-TYPE
      SYNTAX PrtExPVc4CnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtExPVc4CnfgIdx, prtExPVc4SltIdx, prtExPVc4PrtIdx }
      ::= { prtExPVc4CnfgTable 1}

PrtExPVc4CnfgEntry ::=
      SEQUENCE {
        prtExPVc4CnfgIdx      Integer32,
        prtExPVc4SltIdx       INTEGER,
        prtExPVc4PrtIdx       INTEGER,

		prtExPVc4PrtType      INTEGER,
        prtExPVc4Connect      INTEGER,
		prtExPVc4IfType       INTEGER,
        prtExPVc4TxGain       Integer32,
        prtExPVc4RxGain       Integer32,
		prtExPVc4MaxRate      INTEGER,
        prtExPVc4Tc           INTEGER,
        prtExPVc4Oos          INTEGER,
		prtExPVc4EchoCanceler INTEGER,
		prtExPVc4VarDelay     Integer32,
		prtExPVc4CongLevel    Integer32,
		prtExPVc4Wire         INTEGER,
		prtExPVc4ExtensionType		INTEGER,
		prtExPVc4ExtensionNumber	DisplayString,
		prtExPVc4OutPulsing 		INTEGER,
		prtExPVc4HuntGroupMb		INTEGER,
		prtExPVc4HuntGroupIdx		Integer32,
		prtExPVc4AutoFaxMode		INTEGER,
		prtExPVc4FaxRate            INTEGER,
		prtExPVc4SeizeAck           INTEGER,
		prtExPVc4SignalingProtocol  INTEGER,
		prtExPVc4DelayStart         Integer32,
		prtExPVc4WinkMinDuration    Integer32,
		prtExPVc4WinkMaxDuration    Integer32,
        prtExPVc4GenerateTone       INTEGER,
		prtExPVc4CodingLaw          INTEGER,
        prtExPVc4GenerateRingBack   INTEGER,
		prtExPVc4ChannelId          Integer32,
		prtExPVc4PortConnection     INTEGER,
		prtExPVc4CoderAndRate       INTEGER,
		prtExPVc4DestinationNum     DisplayString,
		prtExPVc4DtmfRelay          INTEGER,
		prtExPVc4DiscOnSilence      Integer32,
		prtExPVc4DynamicJitter      INTEGER,
		prtExPVc4EandMType          INTEGER,
		prtExPVc4Rate               Integer32,
		prtExPVc4FrameSize          Integer32,
		prtExPVc4MultiplexInterval  Integer32,
		prtExPVc4TransportProtocol  INTEGER,
		prtExPVc4MultiFreqRelay     INTEGER,
		prtExPVc4MinPulseWidth      Integer32,
		prtExPVc4MinPowerLevel      Integer32,
		prtExPVc4SuperTandem        INTEGER,
		prtExPVc4DestIp             IpAddress,
		prtExPVc4DestBundle         Integer32,
		prtExPVc4SrcIpAddress       IpAddress,
		prtExPVc4SrcIpMask          IpAddress,
		prtExPVc4DefaultGateway     IpAddress,
		prtExPVc4SigPacketInterval	Unsigned32
      }

prtExPVc4CnfgIdx OBJECT-TYPE
      SYNTAX  Integer32  (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx  255 relates to the TmpCnfg"
      ::= {prtExPVc4CnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.

prtExPVc4SltIdx OBJECT-TYPE
      SYNTAX  INTEGER
 {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
    notApplicable (255)
 }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted."
      ::= {prtExPVc4CnfgEntry 2}

prtExPVc4PrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
 {
       exPrt1  (1),
       exPrt2  (2),
       exPrt3  (3),
       exPrt4  (4),
       inPrt1(101),
       inPrt2(102),
       inPrt3(103),
       inPrt4(104),
	   inPrt5(105),
	   inPrt6(106),
	   inPrt7(107),
	   inPrt8(108)
 }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates the port number in the selected card
       (slot)."
      ::= {prtExPVc4CnfgEntry 3}

prtExPVc4PrtType OBJECT-TYPE
      SYNTAX  INTEGER
	{
	      eAndM  (1),
	      fxo    (2),
	      fxs    (3),
	      internal(4),
	      s0      (5),
		  u       (6),
		  sQsig	  (7),
		  uQsig   (8)
	}
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the type of the selected port.
	   In Mx 30/300 phase 4: s0 & u are for Voice over ISDN.
	   In MX 30/300 phase 5: sQsig & uQsig are used for Voice over ISDN with Qsig option.
	   	   
	   In MX MVC4 voice cards, each pair of ports 1-2, 3-4 may have a different type:
       E&M, FXO, FXS.
	   In MVC4 compressed voice cards ports 1..4 have the same interface for all ports.
       In MVC8 compressed voice cards each group of ports 1..4, 5..8 may have
       a different type: E&M, FXO, FXS."
      ::= {prtExPVc4CnfgEntry 4}

prtExPVc4Connect OBJECT-TYPE
      SYNTAX  INTEGER
              {
                no  (2),
                yes (3)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the  port  should be
       considered in any of the mux algorithms."
      ::= {prtExPVc4CnfgEntry 5}

prtExPVc4IfType OBJECT-TYPE
      SYNTAX  INTEGER
              {
                unknown     (1),
                eAndM4wires (2),
   			    eAndM2wires (3),
                fxoGnd      (4),
                fxoLoop     (5),
                fxsGnd      (6),
				fxsLoop     (7),
				e1Framer    (8),
				e1Slave     (9),
				t1Framer   (10),
				t1Slave    (11)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the interface type of the  port.
       eAndM4wires and eAndM2wires - are valid only for E&M
                                     port type
	   eAndM4wires - means 2/4 wires
       fxoGnd and fxoLoop - are valid only for FXO port type
       fxsGnd and fxsLoop - are valid only for FXS port type
       e1Framer, e1Slave, t1Framer, t1Slave - are applicable for the mvc4Pbx
       cards only."
      ::= {prtExPVc4CnfgEntry 6}

prtExPVc4TxGain OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Transmission gain in dB."
      ::= {prtExPVc4CnfgEntry 7}

prtExPVc4RxGain OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Reception gain in dBm."
      ::= {prtExPVc4CnfgEntry 8}

prtExPVc4MaxRate OBJECT-TYPE
      SYNTAX  INTEGER
       {
         notConnected  (1),
         r4800bps      (2),
         r7200bps      (3),
         r9600bps      (4),
		 notApplicatble (255)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Voice rate."
      ::= {prtExPVc4CnfgEntry 9}

prtExPVc4Tc OBJECT-TYPE
      SYNTAX  INTEGER
       {
          t1sec    (1),
          t2sec    (2),
          t3sec    (3),
          t4sec    (4)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Time interval for CIR control, in seconds. The value will
       be the same for all cards' ports."
      ::= {prtExPVc4CnfgEntry 10}

prtExPVc4Oos OBJECT-TYPE
      SYNTAX  INTEGER
       {
          notSupported   (2),
          forcedIdle     (3),
          forcedBusy     (4),
          busyIdle       (5),
          idleBusy       (6)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Handling type, when connection is lost."
      ::= {prtExPVc4CnfgEntry 11}

prtExPVc4EchoCanceler OBJECT-TYPE
      SYNTAX  INTEGER
       {
          off    (2),
          on     (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Echo canceler activation."
      ::= {prtExPVc4CnfgEntry 12}

prtExPVc4VarDelay OBJECT-TYPE
      SYNTAX  Integer32  (0..300)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Maximum variant delay of the FR network, in msec."
      ::= {prtExPVc4CnfgEntry 13}

prtExPVc4CongLevel OBJECT-TYPE
      SYNTAX  Integer32 (0..70)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the level of delayed data in
       precents of total available dynamic memory,
       for which the port will start to operate as congested.
       The resolution of the parameter is 5%."
      ::= {prtExPVc4CnfgEntry 14}

prtExPVc4Wire OBJECT-TYPE
      SYNTAX  INTEGER
       {
          w2wire   (1),
          w4wire   (2),
    notApplicable (255)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the wiring of the E&M port.
       It is applicable only for E&M card type."
      ::= {prtExPVc4CnfgEntry 15}

prtExPVc4ExtensionType OBJECT-TYPE
       SYNTAX  INTEGER
           { notApplicable(1),
             forceConnect(2),
             voiceSwitching(3),
             transparent(4),
             transparentPlus(5),
             ipForceConnect(6),
             permanentDial (7),
             autoAccept (8) }
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
      "This object indicates the type of extension relevant for this port.

       ipForceConnect (6) is used for automatic connection or automatic
       dialing when the phone is off hook (hot line).
       permanentDial (7) means that the call is established upon power up. 
	   The hook may be on or off.
	   Permanent Dialing can be used when there is no signaling. 
	   autoAccept (8) means that the called party in the Permanent Dialing
	   will accept the call from the remote side automatically
	   upon on or off hook."
      ::= {prtExPVc4CnfgEntry 16}

prtExPVc4ExtensionNumber OBJECT-TYPE
       SYNTAX  DisplayString (SIZE(2))
     MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
      "This is the extension number of this port.
      This field is relevant only when the extension
     type is voice switching and is read only if the
     port is member of a hunt group."
      ::= {prtExPVc4CnfgEntry 17}

prtExPVc4OutPulsing OBJECT-TYPE
       SYNTAX  INTEGER { notApplicable(1), no(2), yes(3) }
     MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
      "This field indicates whether to outpulse the received
     digits. It is notApplicable(1) when the extension type
     is forceConnect(2)."
      ::= {prtExPVc4CnfgEntry 18}

prtExPVc4HuntGroupMb OBJECT-TYPE
     SYNTAX  INTEGER { notApplicable(1), no(2), yes(3) }
     MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
      "This object indicates if this port belongs to
      an hunt group."
      ::= {prtExPVc4CnfgEntry 19}

prtExPVc4HuntGroupIdx	OBJECT-TYPE
	    SYNTAX  Integer32(0..10)
    	MAX-ACCESS  read-write
      	STATUS  current
      	DESCRIPTION
     	"If it belongs to an hunt group, this fields
	     indicates the index of the relevant hunt group.
	     0 = notApplicable "
      ::= {prtExPVc4CnfgEntry 20}

prtExPVc4AutoFaxMode	OBJECT-TYPE
    	SYNTAX  INTEGER { notApplicable(1), no(2), yes(3) }
    	MAX-ACCESS  read-write
      	STATUS  current
      	DESCRIPTION
     	"This object indicates if the system will switch automatically to
     	 FAX mode when detecting FAX activity.
     	 Default=Yes."
      ::= {prtExPVc4CnfgEntry 21}

prtExPVc4FaxRate OBJECT-TYPE
      SYNTAX  INTEGER
	      {
          notConnected  (1),
          r4800bps      (2),
		  r7200bps      (3),
		  r9600bps      (4),
		  r12000bps     (5),
		  r14400bps     (6),
          r2400bps      (7),
		  vbdFax        (8)
	      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "FAX initial rate.
       Default=9600 bps."
      ::= {prtExPVc4CnfgEntry 22}

prtExPVc4SeizeAck OBJECT-TYPE
      SYNTAX INTEGER
      {
	  no   (2),
      yes  (3)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This parameter shows whether the device will acknowledge
       a seize signal (On/Off Hook).
       When the value is set to yes(3) & the device receives an on/off hook signal
       it will transmit back an on/off hook signal.
	   When the value is set to no(2) & the device receives an on/off hook signal
       it will NOT transmit back an on/off hook signal.
       
       Example:
       If Seize Ack Parameter = YES, when the MVC.4 receives a seize signal (Off Hook) 
       from the PBX it will send an Off Hook to the PBX.

       The Seize Parameter is relevant for all the following cards:
       MVC-4
       MVC-4/E1-Framer
       MVC-4/T1-DSU-Framer
       MVC-4/T1-CSU-Framer
       MVC-4/E1-SLAVE
       MVC-4/T1-SLAVE

       Default values:
       Analog FXS - No (value can't be changed).
       Analog FXO - Yes (value can't be changed).
       Analog E&M - No (values NO/YES).
       Digital E1/T1 Framer & Slave - No."
      ::= {prtExPVc4CnfgEntry 23}

prtExPVc4SignalingProtocol OBJECT-TYPE
      SYNTAX INTEGER
      {
	  delayStart      (2),
      immediateStart  (3),
	  winkStart       (4)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The signaling protocol that will be used between the PABX & the voice port.

	   Delay Start Protocol: the line is seized by sending an Off hook signal
	   and after a delay, if the called party is available (On hook)   
	   DTMF (Dual Tone Multi Frequency) digits are sent towards the called party.

       Immediate Start Protocol: the line is seized by sending an Off Hook signal
       and immediately DTMF digits are sent towards the called party.
       
       Wink start protocol: the line is seized by sending an Off Hook signal
       and then the called party sends a short Off Hook wink signal.
       Now the calling party starts sending DTMF digits."
      ::= {prtExPVc4CnfgEntry 24} 

prtExPVc4DelayStart OBJECT-TYPE
      SYNTAX Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This parameter is used only for Delay Protocol.
	   This is the time that the calling party will wait after sending an Off hook
	   signal and before sending DTMF digits to the called party.
       The delay values are 100..5000 msec in intervals of 100 msec."
      ::= {prtExPVc4CnfgEntry 25}

prtExPVc4WinkMinDuration OBJECT-TYPE
      SYNTAX Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This parameter is used only for Wink Protocol.
	   Min Duration of the Wink Signal (off hook duration from the called party).
       Legal values: 40..400 msec in intervals of 10 msec."
      ::= {prtExPVc4CnfgEntry 26}

prtExPVc4WinkMaxDuration OBJECT-TYPE
      SYNTAX Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This parameter is used only for Wink Protocol.
	   Max Duration of the Wink Signal (off hook duration from the called party).
       Legal values: 40..400 msec in intervals of 10 msec."
      ::= {prtExPVc4CnfgEntry 27}

prtExPVc4GenerateTone OBJECT-TYPE
      SYNTAX  INTEGER
	      {
          notApplicable  (1),
          no       (2),
		  yes      (3)
		  }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This parameter indicates whether the device (MX or MPH) should generate
       dial tones for the channel.
       If the value is yes (3), it generates dial tones.
       If the value is no  (2), the connected equipment will generate dial tones.
       For example for some ISDN sets the dial tone is generated by the
       phone itself while for others sets it is generated by the MX."
      ::= {prtExPVc4CnfgEntry 28}

prtExPVc4CodingLaw OBJECT-TYPE
      SYNTAX  INTEGER
       {
          aLAW    (1),
          uLAW    (2)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Method/Law for decoding/encoding the voice
       information.
       aLaw(1) is the standard Law for E1 links.
       uLaw(2) is the standard Law for T1 links.

       This object is equal for all the ports in the specific module because
       of HW limitations"
      ::= {prtExPVc4CnfgEntry 29}

prtExPVc4GenerateRingBack OBJECT-TYPE
      SYNTAX  INTEGER
       {
          notApplicable  (1),
          no    (2),
          yes   (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Determines whether the Ring Back tone is generated locally or from the
       remote end.
   	   The default is - NO (Meaning coming from the remote end).
	   Yes means that the Ring Back Tone is generated locally.
       Applicable only for Force Connect."
      ::= {prtExPVc4CnfgEntry 30}

prtExPVc4ChannelId OBJECT-TYPE
      SYNTAX  Integer32 (0..256)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Channel Identifier.
       According to FRF11 each voice port that works as force connect should add a
       CH Id after the DLCI in the frame header.

       Default : 1 

       Applicable only for Force Connect.
       Not Applicable value will be 0."
      ::= {prtExPVc4CnfgEntry 31}

prtExPVc4PortConnection OBJECT-TYPE
      SYNTAX  INTEGER 
       {
	      notApplicable (1),
          line    (2),
          trunk   (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Port connection determines whether the port is connected to a PABX (Trunk) or to
       Telephone set (Line) .

       It determines whether to send certain messages to the port or not.
       If the type is LINE then the port generates a
       ring back tone , if TRUNK it doesn't (The PBX does it)."
      ::= {prtExPVc4CnfgEntry 32}

prtExPVc4CoderAndRate  OBJECT-TYPE
      SYNTAX  INTEGER 
       {
       notApplicable   (1),
       g7231r6300BPS   (2),		                    
       g7231r5300BPS   (3),                
       g729A8KBPS      (4),               
       g711aLAW        (5),                    
       g711uLAW        (6),                     
       g726r16KBPS     (7),                   
       g726r24KBPS     (8),                   
       g726r32KBPS     (9),                   
       g726r40KBPS     (10),                   
       g727r16KBPS     (11),                   
       g727r24r16KBPS  (12),                
       g727r24KBPS     (13),                   
       g727r16r32KBPS  (14),                
       g727r32r24KBPS  (15),                
       g727r32KBPS     (16),                                
       g727r40r16KBPS  (17),                
       g727r40r24KBPS  (18),                
       g727r40r32KBPS  (19),                
       transparent     (20),                    
       netcoder6400BPS (21),              
       netcoder7200BPS (22),              
       netcoder8KBPS   (23),                
       netcoder8800BPS (24),              
       netcoder9600BPS (25),
       lowBitRateR2660BPS (26),
       amr4750BPS      (27), -- Adaptive Multirate Coders of GSM
	   amr5150BPS      (28),
       amr5900BPS      (29),              
       amr6700BPS      (30),
       amr7400BPS      (31),
	   amr7950BPS      (32),
	   amr10200BPS     (33),
	   amr12200BPS     (34)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Coder and Rate for the Voice Compression.
       In MPH: Relevant for MVC-8 card only."
      ::= {prtExPVc4CnfgEntry 33}

prtExPVc4DestinationNum  OBJECT-TYPE
      SYNTAX  DisplayString 
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The destination phone number: 0 to 22 digits.
       Applicable for Auto Dial - ipForceConnect(6), Permanent Dial and 
       Auto Accept Extension Types.      

       Default: Null String"
      ::= {prtExPVc4CnfgEntry 34}
		
prtExPVc4DtmfRelay  OBJECT-TYPE
      SYNTAX  INTEGER 
             {
               disable (2),
               enable  (3)
             }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "When DTMF RELAY is disabled, the DTMF digits (dialed by the user)
       are transmitted as compressed voice and in the remote unit are decompressed.
 
       When DTMF RELAY is enabled, the DTMF digits are detected at the near side and not
       transmitted as voice. Instead, only an indication of what digits were
       dialed are transmitted and in the far end the tone is regenerated."
      ::= {prtExPVc4CnfgEntry 35}

prtExPVc4DiscOnSilence  OBJECT-TYPE
      SYNTAX  Integer32 
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "No. of silenced seconds after which the call will be disconected.
       A value of 0 means that there will be no disconnect when there is silence.
       Possible values: 0 - 900 sec."
      ::= {prtExPVc4CnfgEntry 36}

prtExPVc4DynamicJitter  OBJECT-TYPE
      SYNTAX  INTEGER 
             {
               disable (2),
               enable  (3)
             }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The MVC8 uses two mechanisms to overcome the network delay.
       The first one is a static jitter buffer which holds a constant buffer of up
       to 300 Msec and can be controled by the JITTER parameter (prtExPVc4VarDelay).
       The second one is the dynamic jitter which calculates, in real time,
       the network delay and handles a jitter buffer dynamically.
       The dynamic mechanism that is implemented in MVC8, was intended to overcome
       network delay yet when the network bursts, the MVC8 dynamic mechanism is
       not able to overcome the delay.
       Therefore it is better not to use the dynamic jitter
       (DISABLE - should be the default) where bursts may occur often."
      ::= {prtExPVc4CnfgEntry 37}

prtExPVc4EandMType OBJECT-TYPE
       SYNTAX INTEGER
	   {
       notApplicable (1),
	   type1 (2),
       type2 (3),
       type3 (4),
       ssdc5 (5) 
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This is the signaling type on the E&M analog side.
       The analog signaling includes voltage, no. of pins and other parameters."
       ::= {prtExPVc4CnfgEntry 38}

prtExPVc4Rate OBJECT-TYPE
      SYNTAX Integer32 (0..31)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This is the Rate of the port in TS units. It is used by VF-30 card family.
       0 = NA = port is not intended to be connected; therefore, no Rate."
       ::= {prtExPVc4CnfgEntry 39}

prtExPVc4FrameSize  OBJECT-TYPE
      SYNTAX  Integer32 
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Defines the maximum size in Bytes of the multiplexed frame.
       In some cases this must be limited to avoid IP fragmentation,
       which makes the multiplexing useless, and can also decrease
       the damage in case of frame loss.
       Valid range: 100..1461.
       notApplicable=0."
      ::= {prtExPVc4CnfgEntry 40}

prtExPVc4MultiplexInterval  OBJECT-TYPE
      SYNTAX  Integer32                   
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Defines the maximum amout of time (msec.) between multiplexed frames 
       that are sent.

	   For Vmux-400/420 devices:
	   It defines the Payload Packetizing Interval.

       Valid values: 10-90 msec.
       notApplicable=0."
       ::= {prtExPVc4CnfgEntry 41}

prtExPVc4TransportProtocol OBJECT-TYPE
      SYNTAX INTEGER
	  {
      notApplicable (1),
	  ptp           (2),
      aal2oMpls     (3)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Transport Protocol.
       ptp = point to point.
       aal2oMpls = AAL2 over MPLS."
      ::= {prtExPVc4CnfgEntry 42}

prtExPVc4MultiFreqRelay OBJECT-TYPE
      SYNTAX INTEGER
	  {
      notApplicable (1),
	  disable       (2),
	  enable        (3)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object enables/disables Multi Frequency Signaling Detection."
      ::= {prtExPVc4CnfgEntry 43}

prtExPVc4MinPulseWidth  OBJECT-TYPE
      SYNTAX  Integer32                   
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Defines the minimum Pulse Width in msec.
       Valid values: 45-100 msec.
       notApplicable=0."
       ::= {prtExPVc4CnfgEntry 44}

prtExPVc4MinPowerLevel  OBJECT-TYPE
      SYNTAX  Integer32                   
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Defines the minimum Power Level in dBm.
       Valid values: -1..-35 dBm."
      ::= {prtExPVc4CnfgEntry 45}
	     
prtExPVc4SuperTandem OBJECT-TYPE
      SYNTAX INTEGER
	  {
      notApplicable (1),
	  disable       (2),
	  enable        (3)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The Super Tandem feature provides end to end compression 
       over multiple hops, solving the double compression problem 
       detected in Voice compressing systems.
       The Super Tandem, when enabled, allows transmission of 
       compressed voice between a few devices and eliminates the 
       need to decompress an recompress it over each voice card and 
       PBX, thus improving voice quality and reducing delay."    
      ::= {prtExPVc4CnfgEntry 46}
		      
prtExPVc4DestIp  OBJECT-TYPE
      SYNTAX  IpAddress 
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object defines the destination IP Address."
      ::= {prtExPVc4CnfgEntry 47}

prtExPVc4DestBundle  OBJECT-TYPE
      SYNTAX  Integer32 
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object defines the destination Bundle at the 
       far-end device."
      ::= {prtExPVc4CnfgEntry 48}

prtExPVc4SrcIpAddress  OBJECT-TYPE
      SYNTAX  IpAddress 
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object defines the Source IP Address."
      ::= {prtExPVc4CnfgEntry 49}

prtExPVc4SrcIpMask  OBJECT-TYPE
      SYNTAX  IpAddress 
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object defines the Source IP Mask."
      ::= {prtExPVc4CnfgEntry 50}

prtExPVc4DefaultGateway  OBJECT-TYPE
      SYNTAX  IpAddress 
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object defines the Default Gateway for this interface."
      ::= {prtExPVc4CnfgEntry 51}

prtExPVc4SigPacketInterval OBJECT-TYPE
	SYNTAX		Unsigned32                   
	MAX-ACCESS	read-write
	STATUS		current
	DESCRIPTION
	"Defines the Signaling Packetizing Interval,
	 which is the maximum time interval, measured in msec (milliseconds),
	 between multiplexed signaling frames."
	::= { prtExPVc4CnfgEntry 52 }


--
-- Packet VC4 card
-- External port Dlci table
--
prtExPVc4DlciTable  OBJECT-TYPE
     SYNTAX SEQUENCE OF PrtExPVc4DlciEntry
     MAX-ACCESS not-accessible
     STATUS  current
     DESCRIPTION
      "The write operation into the Table Objects is valid only
       at the TmpCnfg entry."
     ::= {prtPVc4Cnfg 2}

prtExPVc4DlciEntry OBJECT-TYPE
      SYNTAX PrtExPVc4DlciEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtExPVc4DlciCnfgIdx, prtExPVc4DlciSltIdx, prtExPVc4DlciPrtIdx}
      ::= { prtExPVc4DlciTable 1}

PrtExPVc4DlciEntry ::=
      SEQUENCE {
      prtExPVc4DlciCnfgIdx        Integer32,
      prtExPVc4DlciSltIdx         INTEGER,
      prtExPVc4DlciPrtIdx         INTEGER,

      prtExPVc4DlciValid          INTEGER,
      prtExPVc4DlciIConSlt        INTEGER,
      prtExPVc4DlciIConPrt        INTEGER,
      prtExPVc4DlciIConDlci       Integer32,

      prtExPVc4DlciTxBc           INTEGER,
      prtExPVc4DlciTxBe           INTEGER,
      prtExPVc4DlciRxBc           INTEGER,
      prtExPVc4DlciRxBe           INTEGER,

      prtExPVc4DlciPriority       Integer32,

      prtExPVc4DlciStatus         INTEGER
      }


prtExPVc4DlciCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg. "
      ::= { prtExPVc4DlciEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.

prtExPVc4DlciSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
     {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
    notApplicable (255)
     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted.
       In the ?004 Unit the entries io6(10)..io16) are not valid"
      ::= { prtExPVc4DlciEntry 2}

prtExPVc4DlciPrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
 {
          exPrt1  (1) ,
          exPrt2  (2) ,
          exPrt3  (3) ,
    exPrt4  (4)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique internal port number.
       VC4 cards have four external ports."
      ::= { prtExPVc4DlciEntry 3}


prtExPVc4DlciValid OBJECT-TYPE
      SYNTAX  INTEGER
     {
     no  (2),
     yes (3)
     }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the attributes in this
       entry are valid or not. The user can add/delete pvc (dlci
       to dlci connection) by modifing this object"
      ::= { prtExPVc4DlciEntry 4}

prtExPVc4DlciIConSlt OBJECT-TYPE
      SYNTAX  INTEGER
 {
          noConnect (2),
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
    notApplicable (255)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique slot position In the Mux
       (Agent) where the dlci is routed to.
       In the ?004 Unit the entries io6(10)..io16) are not valid"
      ::= { prtExPVc4DlciEntry 5}

prtExPVc4DlciIConPrt OBJECT-TYPE
      SYNTAX  INTEGER
      {
       exPrt1    (1) ,
       exPrt2    (2) ,
       exPrt3    (3) ,
       exPrt4    (4) ,
       exPrt5    (5) ,
       exPrt6    (6) ,
       exPrt7    (7) ,
       exPrt8    (8) ,
       exPrt9    (9) ,
       exPrt10  (10) ,
          noConnect (100),
       inPrt1  (101) ,
       inPrt2  (102) ,
       inPrt3  (103) ,
       inPrt4  (104) ,
       inPrt5  (105) ,
       inPrt6  (106) ,
       inPrt7  (107) ,
       inPrt8  (108) ,
       inPrt9  (109) ,
       inPrt10 (110) ,
    inPrt11 (111) ,
    inPrt12 (112)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique port id which the dlci is
       routed to."
      ::= { prtExPVc4DlciEntry 6}


prtExPVc4DlciIConDlci OBJECT-TYPE
      SYNTAX  Integer32    (1..991)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique internal connection dlci
       number,  the dlci is routed to."
      ::= { prtExPVc4DlciEntry 7}

prtExPVc4DlciTxBc OBJECT-TYPE
      SYNTAX  INTEGER
        {
         full       (1),
         zero       (2),
         txBc9600bps    (3),
        txBc14400bps    (4),
        txBc19200bps    (5),
        txBc28800bps    (6),
        txBc32000bps    (7),
        txBc38400bps    (8),
        txBc48000bps    (9),
        txBc56000bps   (10),
        txBc57600bps   (11),
          txBc64Kbps   (12),
         txBc128Kbps   (13),
         txBc192Kbps   (14),
         txBc256Kbps   (15),
         txBc320Kbps   (16),
         txBc384Kbps   (17),
         txBc448Kbps   (18),
         txBc512Kbps   (19),
         txBc768Kbps   (20),
        txBc1024Kbps   (21),
--
--KM30 ; KM300 additional rates
--
        txBc16000bps   (25),
   txBc112Kbps   (26)
        }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique Tx committed bandwidth on
       the user transmit line (or at the port receive line)."
      ::= { prtExPVc4DlciEntry 8}


prtExPVc4DlciTxBe OBJECT-TYPE
      SYNTAX  INTEGER
        {
         full       (1),
         zero       (2),
         txBe9600bps    (3),
        txBe14400bps    (4),
        txBe19200bps    (5),
        txBe28800bps    (6),
        txBe32000bps    (7),
        txBe38400bps    (8),
        txBe48000bps    (9),
        txBe56000bps   (10),
        txBe57600bps   (11),
          txBe64Kbps   (12),
         txBe128Kbps   (13),
         txBe192Kbps   (14),
         txBe256Kbps   (15),
         txBe320Kbps   (16),
         txBe384Kbps   (17),
         txBe448Kbps   (18),
         txBe512Kbps   (19),
         txBe768Kbps   (20),
        txBe1024Kbps   (21),
--
--KM30 ; KM300 additional rates
--
        txBc16000bps   (25),
   txBc112Kbps   (26)
        }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique Tx excess bandwidth on the
      user transmit line (or at the port receive line)."
      ::= { prtExPVc4DlciEntry 9}


prtExPVc4DlciRxBc OBJECT-TYPE
      SYNTAX  INTEGER
        {
         full       (1),
         zero       (2),
         rxBc9600bps    (3),
        rxBc14400bps    (4),
        rxBc19200bps    (5),
        rxBc28800bps    (6),
        rxBc32000bps    (7),
        rxBc38400bps    (8),
        rxBc48000bps    (9),
        rxBc56000bps   (10),
        rxBc57600bps   (11),
        rxBc64Kbps   (12),
         rxBc128Kbps   (13),
         rxBc192Kbps   (14),
         rxBc256Kbps   (15),
         rxBc320Kbps   (16),
         rxBc384Kbps   (17),
         rxBc448Kbps   (18),
         rxBc512Kbps   (19),
         rxBc768Kbps   (20),
        rxBc1024Kbps   (21),
--
--KM30 ; KM300 additional rates
--
        rxBc16000bps   (25),
   rxBc112Kbps   (26)
        }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique Rx committed bandwidth on the
      user receive line (or at the port transmit line)."
      ::= { prtExPVc4DlciEntry 10}


prtExPVc4DlciRxBe OBJECT-TYPE
      SYNTAX  INTEGER
        {
         full       (1),
         zero       (2),
         rxBe9600bps    (3),
        rxBe14400bps    (4),
        rxBe19200bps    (5),
        rxBe28800bps    (6),
        rxBe32000bps    (7),
        rxBe38400bps    (8),
        rxBe48000bps    (9),
        rxBe56000bps   (10),
        rxBe57600bps   (11),
          rxBe64Kbps   (12),
         rxBe128Kbps   (13),
         rxBe192Kbps   (14),
         rxBe256Kbps   (15),
         rxBe320Kbps   (16),
         rxBe384Kbps   (17),
         rxBe448Kbps   (18),
         rxBe512Kbps   (19),
         rxBe768Kbps   (20),
        rxBe1024Kbps   (21),
--
--KM30 ; KM300 additional rates
--
        rxBc16000bps   (25),
   rxBc112Kbps   (26)
        }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique Rx excess bandwidth on the
      user receive line (or at the port transmit line)."
      ::= { prtExPVc4DlciEntry 11}


prtExPVc4DlciPriority OBJECT-TYPE
      SYNTAX  Integer32  (6..8)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique priority of the pvc.
       6 is the lowest priority and 8 is the highest priority."
      ::= { prtExPVc4DlciEntry 12}



prtExPVc4DlciStatus OBJECT-TYPE
      SYNTAX  INTEGER
 {
          disconnected (1),
          connected    (2)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the status of the pvc. The status is
       disconnected(1) when one of the sides is programmed as not
       connected"
      ::= { prtExPVc4DlciEntry 13}


--
-- Megaplex ?000/?004 LS-6 TDM I/O family card include:
-- Ls6, Ls6V1/E, Ls6V1/O, Ls6V1/S, Ls6V2/E, Ls6V2/O, Ls6V2/S,
-- Ls6Vf/E, Ls6Vf/O, Ls6Vf/S
--
--prtExLs6CnfgTable OBJECT IDENTIFIER ::=  {prtLs6Cnfg 1}
--prtExLs6VCnfgTable OBJECT IDENTIFIER ::= {prtLs6Cnfg 2}
--prtInLs6CnfgTable OBJECT IDENTIFIER ::=  {prtLs6Cnfg 3}

--prtExLs6CnfgTable defines the parameters of the
-- LS-6 cards family external Data ports (1-6) ; LS-12 (1-12)

prtExLs6CnfgTable OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtExLs6CnfgEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
       "The write operation into the Table Objects is valid only
        to the TmpCnfg entry."
      ::= {prtLs6Cnfg 1}

prtExLs6CnfgEntry OBJECT-TYPE
      SYNTAX PrtExLs6CnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtExLs6CnfgIdx, prtExLs6SltIdx, prtExLs6PrtIdx }
      ::= {prtExLs6CnfgTable  1}

PrtExLs6CnfgEntry ::=
      SEQUENCE {
        prtExLs6CnfgIdx    Integer32,
        prtExLs6SltIdx     INTEGER,
        prtExLs6PrtIdx     INTEGER,
        prtExLs6Connect    INTEGER,
        prtExLs6Protocol   INTEGER,
        prtExLs6Rate       INTEGER,
        prtExLs6ClkMode    INTEGER,
        prtExLs6CtrlSignal INTEGER,
        prtExLs6DataBits   INTEGER,
        prtExLs6Cts        INTEGER,
        prtExLs6LinkToInternal INTEGER
      }

prtExLs6CnfgIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx  255 relates to the TmpCnfg"
      ::= {prtExLs6CnfgEntry 1}

prtExLs6SltIdx OBJECT-TYPE
      SYNTAX  INTEGER
          {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
       notApplicable (255)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted.
       In the ?004 Unit the entries io6(10)..io12(16) are not valid."
      ::= {prtExLs6CnfgEntry 2}

prtExLs6PrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
          {
          exPrt1    (1) ,
          exPrt2    (2) ,
          exPrt3    (3) ,
          exPrt4    (4) ,
          exPrt5    (5) ,
          exPrt6    (6) ,
          exPrt7    (7) ,
          exPrt8    (8) ,
          exPrt9    (9) ,
          exPrt10  (10) ,
          exPrt11  (11) ,
          exPrt12  (12)
          }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  port index."
      ::= {prtExLs6CnfgEntry 3}

prtExLs6Connect OBJECT-TYPE
      SYNTAX  INTEGER
              {
                no  (2),
                yes (3)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the  port  should be
       considered in any of the mux algorithms."
      ::= {prtExLs6CnfgEntry 4}

prtExLs6Protocol OBJECT-TYPE
      SYNTAX  INTEGER
              {
                sync  (2),
                async (3)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the protocol.
       async - can be selected only for ports 1-2."
      ::= {prtExLs6CnfgEntry 5}

prtExLs6Rate OBJECT-TYPE
      SYNTAX  INTEGER
       {
          r300bps      (2),
          r600bps      (3),
          r1200bps     (4),
          r2400bps     (5),
          r4800bps     (6),
          r7200bps     (7),
          r8000bps     (8),
          r9600bps     (9),
          r14400bps   (10),
          r16000bps   (11),
          r19200bps   (12),
          r24000bps   (13),
          r28800bps   (14),
          r32000bps   (15),
          r38400bps   (16),
          r48000bps   (17),
          r56000bps   (18),
          r57600bps   (19),
          r64000bps   (20)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Port rates in bps.
       g1 - contains the values : (2)-(6),(9),(12),(16)
       g2 - contains the values : (7),(10),(14),(19)
       g3 - contains the values : (8),(11),(13),(15),(17),(18),(20);
            it is not applicable when using Async protocol.
       Rates of pair ports (1-2, 3-4, 5-6) must be from the same
       group."
      ::= {prtExLs6CnfgEntry 6}

prtExLs6ClkMode OBJECT-TYPE
      SYNTAX  INTEGER
       {
          dce     (1),
          extDce  (2),
          dte1    (3),
          notApplicable (255)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique port operation clock mode.
       It is applicable for Sync protocol only ."
      ::= {prtExLs6CnfgEntry 7}

prtExLs6CtrlSignal OBJECT-TYPE
      SYNTAX  INTEGER
       {
    local     (2),
    rts       (3),
    dtrAndRts (4)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Control Signal."
      ::= {prtExLs6CnfgEntry 8}

prtExLs6DataBits OBJECT-TYPE
      SYNTAX  INTEGER
       {
    d6bits    (1),
    d7bits    (2),
    d8bits    (3),
    d9bits    (4),
    notApplicable (255)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Data Bits.
       This object is applicable for Async protocol only."
      ::= {prtExLs6CnfgEntry 9}

prtExLs6Cts OBJECT-TYPE
      SYNTAX  INTEGER
       {
     notApplicable (1),
     on            (2),
     rts           (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the CTS control line
       operation mode."
      ::= {prtExLs6CnfgEntry 10}

prtExLs6LinkToInternal OBJECT-TYPE
      SYNTAX  INTEGER
          {
          inPrt1        (101) ,
          inPrt2        (102) ,
    notApplicable (255)
          }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates which internal port of the card,
       the external port is linked to."
      ::= {prtExLs6CnfgEntry 11}


--prtExLs6VCnfgTable defines the parameters of the
-- LS-6 cards family external Voice & FAX ports (7-8)

prtExLs6VCnfgTable OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtExLs6VCnfgEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
       "The write operation into the Table Objects is valid only
        to the TmpCnfg entry."
      ::= {prtLs6Cnfg 2}

prtExLs6VCnfgEntry OBJECT-TYPE
      SYNTAX PrtExLs6VCnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtExLs6VCnfgIdx, prtExLs6VSltIdx, prtExLs6VPrtIdx }
      ::= {prtExLs6VCnfgTable  1}


PrtExLs6VCnfgEntry ::=
      SEQUENCE {
        prtExLs6VCnfgIdx       Integer32,
        prtExLs6VSltIdx        INTEGER,
        prtExLs6VPrtIdx        INTEGER,

        prtExLs6VConnect       INTEGER,
        prtExLs6VRate          INTEGER,
        prtExLs6VEchoCanceler  INTEGER,
        prtExLs6VIfType        INTEGER,
        prtExLs6VTxGain        Integer32,
        prtExLs6VRxGain        Integer32,
        prtExLs6VOos           INTEGER
      }

prtExLs6VCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32  (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx  255 relates to the TmpCnfg"
      ::= {prtExLs6VCnfgEntry 1}

prtExLs6VSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
 {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
 }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted.
       In the ?004 Unit the entries io6(10)..io12(16) are not valid."
    ::= {prtExLs6VCnfgEntry 2}

prtExLs6VPrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
 {
       exPrt7    (7) ,
       exPrt8    (8)
 }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A unique identifier of the port, within the card."
      ::= {prtExLs6VCnfgEntry 3}

prtExLs6VConnect OBJECT-TYPE
      SYNTAX  INTEGER
              {
                no  (2),
                yes (3)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the  port  should be
       considered in any of the mux algorithms."
      ::= {prtExLs6VCnfgEntry 4}


prtExLs6VRate OBJECT-TYPE
      SYNTAX  INTEGER
       {
          r6400bps      (2),
    r7200bps      (3),
    r8000bps      (4),
    r9600bps      (5),
    r16000bps     (6),
    r24000bps     (7),
    r32000bps     (8),
    r64000bps     (9)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Rate (bps) used for FAX transmission and Voice coding."
      ::= {prtExLs6VCnfgEntry 5}

prtExLs6VEchoCanceler OBJECT-TYPE
      SYNTAX  INTEGER
       {
          off    (2),
          on     (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Echo canceler activation."
      ::= {prtExLs6VCnfgEntry 6}

prtExLs6VIfType OBJECT-TYPE
      SYNTAX  INTEGER
              {
          w2wire   (1),
          w4wire   (2)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the interface type of the  port.
       w4wire - is applicable only for E&M port type."
      ::= {prtExLs6VCnfgEntry 7}

prtExLs6VTxGain OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Transmit gain in dBm.
       E&M - values range: -17 .. 8
       FXO - values range: -16 .. 4
       FXS - values range: -13 .. 8  "
      ::= {prtExLs6VCnfgEntry 8}

prtExLs6VRxGain OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Receive gain in dBm.
       E&M - values range: -17 .. 2
       FXO - values range: -17 .. -1
       FXS - values range: -17 .. 2  "
      ::= {prtExLs6VCnfgEntry 9}

prtExLs6VOos OBJECT-TYPE
      SYNTAX  INTEGER
       {
          forcedIdle     (1),
          forcedBusy     (2),
          busyIdle       (3),
          idleBusy       (4)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Out of Service signaling mode."
      ::= {prtExLs6VCnfgEntry 10}



-- Ls6 and Ls12 Internal composite channel parameters
--

prtInLs6CnfgTable OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtInLs6CnfgEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
       "The write operation into the Table Objects is valid only
        to the TmpCnfg entry."
      ::= {prtLs6Cnfg 3}

prtInLs6CnfgEntry OBJECT-TYPE
      SYNTAX PrtInLs6CnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtInLs6CnfgIdx, prtInLs6SltIdx, prtInLs6PrtIdx }
      ::= {prtInLs6CnfgTable 1}

PrtInLs6CnfgEntry ::=
      SEQUENCE {
        prtInLs6CnfgIdx    Integer32,
        prtInLs6SltIdx     INTEGER,
        prtInLs6PrtIdx     INTEGER,
        prtInLs6Connect    INTEGER,
        prtInLs6TandemMode INTEGER,
        prtInLs6Rate       INTEGER,
        prtInLs6RemoteType INTEGER,
        prtInLs6LinkTo     INTEGER
      }

prtInLs6CnfgIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx  255 relates to the TmpCnfg"
      ::= {prtInLs6CnfgEntry 1}

prtInLs6SltIdx OBJECT-TYPE
      SYNTAX  INTEGER
          {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted.
       In the ?004 Unit the entries io6(10)..io12(16) are not valid."
      ::= {prtInLs6CnfgEntry 2}

prtInLs6PrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
          {
          inPrt1    (101),
          inPrt2    (102)
          }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique internal port index."
      ::= {prtInLs6CnfgEntry 3}

prtInLs6Connect OBJECT-TYPE
      SYNTAX  INTEGER
              {
                no  (2),
                yes (3)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the port should be considered in
       any of the mux  algorithms. It also affects all the module
       considerations because the module has only one Internal
       interface which is the composite channel."
      ::= {prtInLs6CnfgEntry 4}

prtInLs6TandemMode  OBJECT-TYPE
      SYNTAX  INTEGER
       {
     noTandem     (1),
     tandemMaster (2),
     tandemSlave  (3)
    }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the Tandem Mode.
       tandemSlave - is valid only for an LS-6 card having on
    the (current slot-1) an LS-6 card with 'tandemMaster' mode."
       ::= {prtInLs6CnfgEntry 5}

prtInLs6Rate OBJECT-TYPE
      SYNTAX  INTEGER
       {
     r32Kbps   (1),
     r56Kbps   (2),
     r64Kpbs   (3),
     r128Kbps  (4),
     r256Kbps  (5),
     r384Kbps  (6),
     r192Kbps  (7),
     r512Kbps  (8),
     r768Kbps  (9),
	 r14400bps(10) 
    }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Main Rate in Kbps."
      ::= {prtInLs6CnfgEntry 6}

prtInLs6RemoteType OBJECT-TYPE
      SYNTAX  INTEGER
       {
     ls6            (1),
     km2kSlave      (2),
     km2kStandalone (3),
     notApplicable (255)
    }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Remote Type.
       notApplicable - when prtInLs6TandemMode=tandemSlave "
      ::= {prtInLs6CnfgEntry 7}

prtInLs6LinkTo OBJECT-TYPE
      SYNTAX  INTEGER
       {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
    notApplicable (255)
       }
      MAX-ACCESS  read-write
      STATUS  deprecated
      DESCRIPTION
      "It indicates the slot of the main link card to which the
       Ls6 card is mapped.
       In the ?004 Unit the entries io6(10)..io12(16) are not valid.
       notApplicable - when prtInLs6TandemMode=tandemSlave.
       STATUS  deprecated - this object is replaced by prtGenCnfgLinkToSlot
       and prtGenCnfgLinkToPort. "
      ::= {prtInLs6CnfgEntry 8}

--
-- Megaplex?000/?004 VC-3 TDM I/O family port.
-- (VC3/E&M,VC3/FXO,VC3/FXS)
--
--

--prtExVc3CnfgTable defines the parameters of the
-- VC-3 and VF-3 cards family external ports

prtExVc3CnfgTable OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtExVc3CnfgEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
       "The write operation into the Table Objects is valid only
        to the TmpCnfg entry."
      ::= { prtVc3Cnfg 1}

prtExVc3CnfgEntry OBJECT-TYPE
      SYNTAX PrtExVc3CnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtExVc3CnfgIdx, prtExVc3SltIdx, prtExVc3PrtIdx }
      ::= { prtExVc3CnfgTable 1}

PrtExVc3CnfgEntry ::=
      SEQUENCE {
        prtExVc3CnfgIdx        Integer32,
        prtExVc3SltIdx         INTEGER,
        prtExVc3PrtIdx         INTEGER,

        prtExVc3Connect      INTEGER,
        prtExVc3TransGain    Integer32,
        prtExVc3ReceiveGain  Integer32,
        prtExVc3Wire         INTEGER,
        prtExVc3Rate         INTEGER,
        prtExVc3EchoCanceler INTEGER
      }

prtExVc3CnfgIdx OBJECT-TYPE
      SYNTAX  Integer32  (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx  255 relates to the TmpCnfg"
      ::= {prtExVc3CnfgEntry 1}

prtExVc3SltIdx OBJECT-TYPE
      SYNTAX  INTEGER
 {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
 }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted.
       In the ?004 Unit the entries io6(10)..io12(16) are not valid."
      ::= {prtExVc3CnfgEntry 2}

prtExVc3PrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
 {
       exPrt1    (1) ,
       exPrt2    (2) ,
       exPrt3    (3)
 }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A unique identifier of the port, within the card."
      ::= {prtExVc3CnfgEntry 3}

prtExVc3Connect OBJECT-TYPE
      SYNTAX  INTEGER
              {
                no  (2),
                yes (3)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the  port  should be
       considered in any of the mux algorithms."
      ::= {prtExVc3CnfgEntry 4}

prtExVc3TransGain OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Transmit gain in dBm."
      ::= {prtExVc3CnfgEntry 5}

prtExVc3ReceiveGain OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Receive gain in dBm."
      ::= {prtExVc3CnfgEntry 6}

prtExVc3Wire OBJECT-TYPE
      SYNTAX  INTEGER
       {
          w2wire   (1),
          w4wire   (2)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object is equal for all the ports in the specific
       card because of HW limitations"
      ::= {prtExVc3CnfgEntry 7}

prtExVc3Rate OBJECT-TYPE
      SYNTAX  INTEGER
       {
          r9600bps    (1),
    r4800bps    (2)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Rate in bps."
      ::= {prtExVc3CnfgEntry 8}

prtExVc3EchoCanceler OBJECT-TYPE
      SYNTAX  INTEGER
       {
          off    (2),
          on     (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Echo canceler activation. The value will be the same for
       all the card's external ports."
      ::= {prtExVc3CnfgEntry 9}

--prtInVc3CnfgTable defines the parameters of the
-- VC-3 or VF-3 cards family internal ports

prtInVc3CnfgTable OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtInVc3CnfgEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
       "The write operation into the Table Objects is valid only
        to the TmpCnfg entry."
      ::= { prtVc3Cnfg 2}

prtInVc3CnfgEntry OBJECT-TYPE
      SYNTAX PrtInVc3CnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtInVc3CnfgIdx, prtInVc3SltIdx, prtInVc3PrtIdx }
      ::= { prtInVc3CnfgTable 1}

PrtInVc3CnfgEntry ::=
      SEQUENCE {
        prtInVc3CnfgIdx        Integer32,
        prtInVc3SltIdx         INTEGER,
        prtInVc3PrtIdx         INTEGER,

        prtInVc3Connect        INTEGER,
        prtInVc3Rate           INTEGER,
        prtInVc3Oos            INTEGER,
        prtInVc3LinkTo         INTEGER

      }

prtInVc3CnfgIdx OBJECT-TYPE
      SYNTAX  Integer32  (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx  255 relates to the TmpCnfg"
      ::= {prtInVc3CnfgEntry 1}

prtInVc3SltIdx OBJECT-TYPE
      SYNTAX  INTEGER
 {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
 }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted.
       In the ?004 Unit the entries io6(10)..io12(16) are not valid."
      ::= {prtInVc3CnfgEntry 2}

prtInVc3PrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
 {
       inPrt1    (101)
 }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A unique identifier of the port, within the card."
      ::= {prtInVc3CnfgEntry 3}

prtInVc3Connect OBJECT-TYPE
      SYNTAX  INTEGER
              {
                no  (2),
                yes (3)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the  port  should be
       considered in any of the mux algorithms."
      ::= {prtInVc3CnfgEntry 4}

prtInVc3Rate OBJECT-TYPE
      SYNTAX  INTEGER
       {
          r32000bps    (1),
    r16000bps    (2)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Rate in bps."
      ::= {prtInVc3CnfgEntry 5}

prtInVc3Oos OBJECT-TYPE
      SYNTAX  INTEGER
       {
          forcedIdle     (1),
          forcedBusy     (2),
          busyIdle       (3),
          idleBusy       (4)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      " This object is equal for all the ports in the specific
        card because of HW limitations"
      ::= {prtInVc3CnfgEntry 6}

prtInVc3LinkTo OBJECT-TYPE
      SYNTAX  INTEGER
       {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
       }
      MAX-ACCESS  read-write
      STATUS  deprecated
      DESCRIPTION
      "This attribute indicates the slot of the ML card to which
       the VC card is mapped.
       In the ?004 Unit the entries io6(10)..io12(16) are not valid.
       STATUS  deprecated - this object is replaced by prtGenCnfgLinkToSlot
       and prtGenCnfgLinkToPort."
      ::= {prtInVc3CnfgEntry 7}


--
-- Megaplex?000/?004 VC-3 TDM I/O family port.
-- (VC-PBX, VC-PBX/T1,VC-PBX/E1)
--
--

--prtExVcPbxCnfgTable defines the parameters of the
-- VC-PBX or VF-PBX cards family external ports

prtExVcPbxCnfgTable OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtExVcPbxCnfgEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
       "The write operation into the Table Objects is valid only
        to the TmpCnfg entry."
      ::= { prtVcPbxCnfg 1}

prtExVcPbxCnfgEntry OBJECT-TYPE
      SYNTAX PrtExVcPbxCnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtExVcPbxCnfgIdx, prtExVcPbxSltIdx, prtExVcPbxPrtIdx }
      ::= { prtExVcPbxCnfgTable 1}

PrtExVcPbxCnfgEntry ::=
      SEQUENCE {
        prtExVcPbxCnfgIdx        Integer32,
        prtExVcPbxSltIdx         INTEGER,
        prtExVcPbxPrtIdx         INTEGER,

        prtExVcPbxConnect        INTEGER,
        prtExVcPbxGroup          INTEGER,
        prtExVcPbxTransparent    INTEGER,
        prtExVcPbxTransSignalTs  Integer32,
        prtExVcPbxFrame          INTEGER,
        prtExVcPbxRestoreTime    INTEGER,
  prtExVcPbxLineCode       INTEGER,
        prtExVcPbxLineLength     INTEGER,
        prtExVcPbxLinkTo         INTEGER,
     prtExVcPbxSignalOper     INTEGER,
  prtExVcPbxIdleCode       INTEGER
      }

prtExVcPbxCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32  (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx  255 relates to the TmpCnfg"
      ::= {prtExVcPbxCnfgEntry 1}

prtExVcPbxSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
 {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
 }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates a unique  slot  position where
       the card is inserted.
       In the ?004 Unit the entries io6(10)..io12(16) are not valid."
      ::= {prtExVcPbxCnfgEntry 2}

prtExVcPbxPrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
 {
       exPrt1    (1)
 }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A unique identifier of the port, within the card."
      ::= {prtExVcPbxCnfgEntry 3}

prtExVcPbxConnect OBJECT-TYPE
      SYNTAX  INTEGER
              {
                no  (2),
                yes (3)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates whether the  port  should be
       considered in any of the mux algorithms."
      ::= {prtExVcPbxCnfgEntry 4}

prtExVcPbxGroup OBJECT-TYPE
      SYNTAX  INTEGER
 {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
    notApplicable (255)
 }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The group object links together several VC-PBX cards,
       concerning compression of the same input T1/E1 link
       time-slots.
       When ports of different slots have the same group, they are
       linked.
       When ports have a different group, they are not linked.
    For VC-PBX/T1 and E1 cards, this object is - their own
    IO Slot.
       In the ?004 Unit the entries io6(10)..io12(16) are not valid."
      ::= {prtExVcPbxCnfgEntry 5}

prtExVcPbxTransparent     OBJECT-TYPE
      SYNTAX  INTEGER
              {
                no  (2),
                yes (3),
    notApplicable (255)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates whether the Transparent transfer
       of Time-Slots is required or not.
       Time-Slots transferred by Transparent, will not be
       compressed.
       no  - applicable only for VC-PBX/T1 and VC-PBX/E1 cards
       yes - applicable only for VC-PBX/T1 and VC-PBX/E1 cards
       notApplicable - only for VC-PBX cards."
      ::= {prtExVcPbxCnfgEntry 6}

prtExVcPbxTransSignalTs     OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object specifies the ML Time-Slot dedicated to
       the signaling of the PABX Transparent TSs.
       None = 255.
       When prtExVcPbxTransparent=no this object's value=None (255)
       When prtExVcPbxTransparent=notApplicable, this object's
       value=None (255).
       When prtExVcPbxTransparent=yes:
    - for VC-PBX/T1 ports, this object's valid values are 1..16
      or None (255).
       - for VC-PBX/E1 ports, this object's value will be 16 or None
      (255)."
      ::= {prtExVcPbxCnfgEntry 7}

prtExVcPbxFrame OBJECT-TYPE
      SYNTAX  INTEGER
       {
  esfT1          (2), --> dsx1ESF
  sfT1           (3), --> dsx1D4
  g732nE1        (4), --> dsx1E1
  g732nE1CRC     (5), --> dsx1E1-CRC
  g732sE1        (6), --> dsx1E1-MF
  g732sE1CRC     (7),  --> dsx1E1-MF-CRC
  notApplicable  (255)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object is the frame parameter for T1/E1 interface.
       The user should select only the parameters which are relevant
       to the specific card:
       T1 values for the VC-PBX/T1 card.
       E1 values for the VC-PBX/E1 card.
    notApplicable - for the VC-PBX card.
       This parameter has the same values as dsx1LineType in T1/E1
       MIB (RFC-1406). The parameters in dsx1LineType are:
                     other          (1)
      esfT1          dsx1ESF        (2)
      sfT1           dsx1D4         (3)
      g732nE1        dsx1E1         (4)
      g732nE1CRC     dsx1E1-CRC     (5)
      g732sE1        dsx1E1-MF      (6)
      g732sE1CRC     dsx1E1-MF-CRC  (7)  "
      ::= {prtExVcPbxCnfgEntry 8}

prtExVcPbxRestoreTime OBJECT-TYPE
      SYNTAX  INTEGER
       {
        restoreT1secFast      (2),
        restoreT10sec62411    (3),
        ccittE1               (4),
  notApplicable         (255)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The time passing from the disappearance of the loss of
       synchronization condition (red alarm) to the restoration of
       normal service. The options 1secFast(2) and 10sec62411(3)
       for E1 interfaces are proprietary implementation of the T1
       standard to the E1 interface.
       ccittE1 - is applicable only for VC-PBX/E1 card
       notApplicable - is applicable for VC-PBX card"
      ::= {prtExVcPbxCnfgEntry 9}

prtExVcPbxLineCode OBJECT-TYPE
      SYNTAX  INTEGER
       {
  b7zsT1 (1),  --> dsx1JBZS
  b8zsT1 (2),  --> dsx1B8ZS
        transT1(3),  --> dsx1AMI
        hdb3E1 (4),  --> dsx1HDB3
  notApplicable (255)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object is the line code parameter used for T1/E1
       interface.
       The user should select only the parameters which are relevant
       to the specific card:
       T1 line code parameters for VC-PBX/T1
       E1 line code parameters for VC-PBX/E1
    notApplicable - for VC-PBX
       This parameter has the same values as dsx1LineCoding in T1/E1
       MIB (RFC-1406).  The parameters in dsx1LineCoding are:
     dsx1JBZS  (1)
     dsx1B8ZS  (2)
     dsx1HDB3  (3)
     dsx1ZBTSI (4)
     dsx1AMI   (5)
     other     (6)"
      ::= {prtExVcPbxCnfgEntry 10}

prtExVcPbxLineLength OBJECT-TYPE
      SYNTAX  INTEGER
       {
        unknown      (1),
        len0p133ft   (2),
        len134p266ft (3),
        len267p399ft (4),
        len400p533ft (5),
        len534p655ft (6),
        notApplicable (255)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object is the line length parameter.
       It is applicable only for the VC-PBX/T1 card.
       notApplicable - for the VC-PBX and VC-PBX/E1 card.
       lenXXXpXXXft = len-XXX-XXXft."
      ::= {prtExVcPbxCnfgEntry 11}

prtExVcPbxLinkTo OBJECT-TYPE
      SYNTAX  INTEGER
       {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
    notApplicable (255)
       }
      MAX-ACCESS  read-write
      STATUS  deprecated
      DESCRIPTION
      "This object indicates the slot of the ML card to which
       the VC-PBX/T1, VC-PBX/E1 card Transparent TSs are mapped.
       notApplicable - for VC-PBX card AND
       for VC-PBX/T1, VC-PBX/E1 cards, when prtExVcPbxTransparent=no .
       In the ?004 Unit the entries io6(10)..io12(16) are not valid.
       STATUS  deprecated - this object is replaced by prtGenCnfgLinkToSlot
       and prtGenCnfgLinkToPort."
      ::= {prtExVcPbxCnfgEntry 12}

prtExVcPbxSignalOper OBJECT-TYPE
      SYNTAX  INTEGER
          {
          notApplicable (1),
          normal        (2),
          bEqA          (3),
    inverseA      (4)
          }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the Signaling Operation of the
       VC-PBX/T1, VC-PBX/E1 external port.
       notApplicable - for VC-PBX card
    normal - all 4 signaling bits are transferred.
    bEqA   - copy the A bit into the B bit. Applicable only for
             VC-PBX/T1."
      ::= {prtExVcPbxCnfgEntry 13}

prtExVcPbxIdleCode OBJECT-TYPE
      SYNTAX  INTEGER
          {
          notApplicable  (1),
          hff            (2),
          he4            (3),
    hd5            (4),
    h9e            (5),
    h98            (6),
    h7f            (7),
    h7e            (8),
    h54            (9),
    h1a           (10)
          }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Determines the code for transmission in empty time slots.
       notApplicable - for VC-PBX card ."
      ::= {prtExVcPbxCnfgEntry 14}



--prtIn1p6VcPbxCnfgTable defines the parameters of the
-- VC-PBX or VF-PBX cards family internal ports 1-6

prtIn1p6VcPbxCnfgTable OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtIn1p6VcPbxCnfgEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
       "The write operation into the Table Objects is valid only
        to the TmpCnfg entry."
      ::= { prtVcPbxCnfg 2}

prtIn1p6VcPbxCnfgEntry OBJECT-TYPE
      SYNTAX PrtIn1p6VcPbxCnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtIn1p6VcPbxCnfgIdx, prtIn1p6VcPbxSltIdx, prtIn1p6VcPbxPrtIdx }
      ::= { prtIn1p6VcPbxCnfgTable 1}

PrtIn1p6VcPbxCnfgEntry ::=
      SEQUENCE {
        prtIn1p6VcPbxCnfgIdx        Integer32,
        prtIn1p6VcPbxSltIdx         INTEGER,
        prtIn1p6VcPbxPrtIdx         INTEGER,

        prtIn1p6VcPbxConnect      INTEGER,
        prtIn1p6VcPbxRate         INTEGER,
        prtIn1p6VcPbxEchoCanceler INTEGER,
        prtIn1p6VcPbxPabxTs       Integer32 
	}

prtIn1p6VcPbxCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32  (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx  255 relates to the TmpCnfg"
      ::= {prtIn1p6VcPbxCnfgEntry 1}

prtIn1p6VcPbxSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
 {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
 }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates a unique  slot  position where
       the card is inserted.
       In the ?004 Unit the entries io6(10)..io12(16) are not valid."
      ::= {prtIn1p6VcPbxCnfgEntry 2}

prtIn1p6VcPbxPrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
 {
       inPrt1  (101) ,
       inPrt2  (102) ,
       inPrt3  (103) ,
       inPrt4  (104) ,
       inPrt5  (105) ,
       inPrt6  (106)
 }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A unique identifier of the port, within the card."
      ::= {prtIn1p6VcPbxCnfgEntry 3}

prtIn1p6VcPbxConnect OBJECT-TYPE
      SYNTAX  INTEGER
              {
                no  (2),
                yes (3)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates whether the  port  should be
       considered in any of the mux algorithms."
      ::= {prtIn1p6VcPbxCnfgEntry 4}

prtIn1p6VcPbxRate OBJECT-TYPE
      SYNTAX  INTEGER
              {
                r4800bps  (1),
                r6400bps  (2),
                r7200bps  (3),
                r8000bps  (4),
    r9600bps  (5),
    r12800bps (6)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the port Rate.
       For Normal mode (prtIn7p8VcPbxMode=normal), only part of the values
       are valid (constant rate).
       For Server mode (prtIn7p8VcPbxMode=server), all values are
       applicable (user can select the desired compression rate). "
      ::= {prtIn1p6VcPbxCnfgEntry 5}

prtIn1p6VcPbxEchoCanceler OBJECT-TYPE
      SYNTAX  INTEGER
       {
          off    (2),
          on     (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Echo canceler activation."
      ::= {prtIn1p6VcPbxCnfgEntry 6}

prtIn1p6VcPbxPabxTs OBJECT-TYPE
      SYNTAX  Integer32 (1..31)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object defines the PABX Time-Slot assigned to this
       internal port.
       For a  T1 link, the valid values are: 1 .. 24.
       For an E1 link, the valid values are: 1 .. 31.
       This object is NOT applicable when prtIn1p6VcPbxConnect=no.
       This object is applicable for all cards of VC-PBX family.
       Default=the internal port index (1..6)."
      ::= {prtIn1p6VcPbxCnfgEntry 7}

--prtIn7p8VcPbxCnfgTable defines the parameters of the
-- VC-PBX or VF-PBX cards family internal ports 7-8

prtIn7p8VcPbxCnfgTable OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtIn7p8VcPbxCnfgEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
       "The write operation into the Table Objects is valid only
        to the TmpCnfg entry."
      ::= { prtVcPbxCnfg 3}

prtIn7p8VcPbxCnfgEntry OBJECT-TYPE
      SYNTAX PrtIn7p8VcPbxCnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtIn7p8VcPbxCnfgIdx, prtIn7p8VcPbxSltIdx, prtIn7p8VcPbxPrtIdx }
      ::= { prtIn7p8VcPbxCnfgTable 1}

PrtIn7p8VcPbxCnfgEntry ::=
      SEQUENCE {
        prtIn7p8VcPbxCnfgIdx        Integer32,
        prtIn7p8VcPbxSltIdx         INTEGER,
        prtIn7p8VcPbxPrtIdx         INTEGER,

        prtIn7p8VcPbxConnect      INTEGER,
        prtIn7p8VcPbxMode         INTEGER,
        prtIn7p8VcPbxRate         INTEGER,
        prtIn7p8VcPbxSignalMode   INTEGER,
        prtIn7p8VcPbxOos          INTEGER,
        prtIn7p8VcPbxLinkTo       INTEGER
      }

prtIn7p8VcPbxCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32  (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx  255 relates to the TmpCnfg"
      ::= {prtIn7p8VcPbxCnfgEntry 1}

prtIn7p8VcPbxSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
 {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
 }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates a unique  slot  position where
       the card is inserted.
       In the ?004 Unit the entries io6(10)..io12(16) are not valid."
      ::= {prtIn7p8VcPbxCnfgEntry 2}

prtIn7p8VcPbxPrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
 {
       inPrt7  (107) ,
       inPrt8  (108)
 }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A unique identifier of the port, within the card."
      ::= {prtIn7p8VcPbxCnfgEntry 3}

prtIn7p8VcPbxConnect OBJECT-TYPE
      SYNTAX  INTEGER
              {
                no  (2),
                yes (3)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates whether the  port  should be
       considered in any of the mux algorithms."
      ::= {prtIn7p8VcPbxCnfgEntry 4}

prtIn7p8VcPbxMode OBJECT-TYPE
      SYNTAX  INTEGER
              {
                normal  (1),
                server  (2)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the working mode of the port:
       - normal - the compressed voice will be sent to an MTML
                  card inside the Mux.
       - server - the compressed voice will be sent to the Digital
                  Voice connector, as a service to an outside user."
      ::= {prtIn7p8VcPbxCnfgEntry 5}

prtIn7p8VcPbxRate OBJECT-TYPE
      SYNTAX  INTEGER
              {
                r32Kbps  (1),
    r16Kbps  (2),
                notApplicable (255)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the port Main Rate.
       For Server mode (prtIn7p8VcPbxMode=server), the value will
       be notApplicable. "
      ::= {prtIn7p8VcPbxCnfgEntry 6}

prtIn7p8VcPbxSignalMode OBJECT-TYPE
      SYNTAX  INTEGER
              {
                none    (1),
                aBit    (2),
    abcBit  (3),
    abcdBit (4)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the Signal Mode.
       For Server mode (prtIn7p8VcPbxMode=server), the only valid
       values are:
       - none
       - aBit "
      ::= {prtIn7p8VcPbxCnfgEntry 7}

prtIn7p8VcPbxOos OBJECT-TYPE
      SYNTAX  INTEGER
       {
          forcedIdle     (1),
          forcedBusy     (2)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      " Out of service Signaling mode."
      ::= {prtIn7p8VcPbxCnfgEntry 8}

prtIn7p8VcPbxLinkTo OBJECT-TYPE
      SYNTAX  INTEGER
       {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
       notApplicable (255)
       }
      MAX-ACCESS  read-write
      STATUS  deprecated
      DESCRIPTION
      "This object indicates the slot of the ML card to which
       the VC card is mapped.
       In the ?004 Unit the entries io6(10)..io12(16) are not valid.
       For Server mode (prtIn7p8VcPbxMode=server), this object is
       not applicable.
       Both ports, 7 and 8 should be linked to the same Slot.
       STATUS  deprecated - this object is replaced by prtGenCnfgLinkToSlot
       and prtGenCnfgLinkToPort."
      ::= {prtIn7p8VcPbxCnfgEntry 9}

--prtExVcPbxTsTable defines PABX Time Slots assignment of the
-- VC-PBX E1/T1 cards, VF-PBX cards , VF-24/30/48/60 T1/E1 cards
-- and VFS cards

prtExVcPbxTsTable OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtExVcPbxTsEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
       "The write operation into the table objects is valid only
        to the TmpCnfg entry."
      ::= { prtVcPbxCnfg 4}

prtExVcPbxTsEntry OBJECT-TYPE
      SYNTAX PrtExVcPbxTsEntry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION  "An entry in table."
	  INDEX {prtExVcPbxTsCnfgIdx, prtExVcPbxTsSltIdx, prtExVcPbxTsPrtIdx, prtExVcPbxTsIdx }
      ::= { prtExVcPbxTsTable 1}

PrtExVcPbxTsEntry ::=
      SEQUENCE {
      prtExVcPbxTsCnfgIdx        Integer32,
      prtExVcPbxTsSltIdx         INTEGER,
      prtExVcPbxTsPrtIdx         INTEGER,
      prtExVcPbxTsIdx            Integer32,
      prtExVcPbxTsMode           INTEGER,
      prtExVcPbxTsIConSlot       INTEGER,
      prtExVcPbxTsIConPrt        INTEGER,
	  prtExVcPbxTsIConTs         Integer32,
	  prtExVcPbxTsRemPrt         INTEGER,
	  prtExVcPbxTsRemTs          Integer32,
	  prtExVcPbxTsRemConnID      Unsigned32,
	  prtExVcPbxTsSourceSlot     INTEGER, 
      prtExVcPbxTsSourcePrt      Unsigned32
	  }

prtExVcPbxTsCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32  (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg. "
      ::= { prtExVcPbxTsEntry 1}

prtExVcPbxTsSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
     {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted.
       In the ?004 Unit the entries io6(10)..io12(16) are not valid"
      ::= { prtExVcPbxTsEntry 2}

prtExVcPbxTsPrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
      {
          exPrt1    (1),
		  exPrt2    (2),
		  inPrt9  (109),
		  inPrt10 (110) 
      }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  port number.
       VCPBX/E1, VCPBX/T1, VFPBX/E1, VFPBX/T1, VF-24/T1 and VF-30 cards 
       have only one external interface.
       VF-48/T1 and VF-60/E1 cards have two external interfaces.
       VFS cards have also internal ports."
      ::= { prtExVcPbxTsEntry 3}

prtExVcPbxTsIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique PABX time slot  position.
       The valid time slots are 1..24 for T1 cards and
       1..31 for E1 cards."
      ::= { prtExVcPbxTsEntry 4}

prtExVcPbxTsMode OBJECT-TYPE
      SYNTAX  INTEGER
              {
                unused       (1),
                compressed   (2),  -- =compressedVoice
                transparent  (3),
				compressedCcs(4),
				mng          (5),
				ccs1        (11),
				ccs2        (12),
				ccs3        (13),
				ccs4        (14),
				ccs5        (15),
				ccs6        (16),
				ccs7        (17),
				ccs8        (18),
				ss7n1       (41),
				ss7n2       (42),
				ss7n3       (43),
				ss7n4       (44),
				ss7n5       (45),
				ss7n6       (46),
				ss7n7       (47),
				ss7n8       (48)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the usage, process and way of the
       specific PABX TS towards its destination:
       unused - the TS is not used (no processing, no destination).
       compressed - the TS is used, sent for compression to an
                internal port (for VF-PBX cards: 1..6 for of either 
                the same card or a VF-PBX card of the same group).
				For VF-24/30/48/60 - 'compressed' represents 'compressed Voice'
				(to differentiate it from 'compressedCcs').
				In this case, the TS is compressed by an internal port (1..8). 
       transparent - the TS is used; no processing. It is sent
                directly for Bypass to a ML card the VF port/TS is linked to.
       compressedCcs - supported only by VF-24/30/48/60 cards. The TS is used;
                sent for compression to the CPU.
       mng    - the TS is used for Management (this option is used when the 
                external port is connected to another product that has to be 
                managed via this dedicated TS.
	   ccs1..ccs8 - supported only by VF-24/30/48/60 cards. Compressed TS that
	            comes from a bundle of V5.1 or V5.2 PBX.
       ss7n1..ss7n8 - supported only by VF-24/30/48/60 cards. Compressed TS that
	            comes from a bundle of V5.1 or V5.2 PBX. ss7n1 can work versus
	            Vmux having prtExPh1MlTsType=ss7(6)."
      ::= { prtExVcPbxTsEntry 5}

prtExVcPbxTsIConSlot OBJECT-TYPE
      SYNTAX  INTEGER
       {
          noConnect (2),
          io1       (5),
          io2       (6),
          io3       (7),
          io4       (8),
          io5       (9),
          io6      (10),
          io7      (11),
          io8      (12),
          io9      (13),
          io10     (14),
          io11     (15),
          io12     (16)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "For VF-PBX cards, the io1..io12 values are applicable only when
       prtExVcPbxTsMode=compressed. Otherwise, its value should be
       noConnect.
	   For VF-24/30/48/60 cards:
	   - when prtExVcPbxTsMode=transparent or voiceTransparent, the io1..io12 values are applicable,
	     indicating the ML Slot this TS is connected to.
	   - when prtExVcPbxTsMode=compressed or compressedCcs, the	value
	     will be the same as prtExVcPbxTsSltIdx, since the compression is 
	     done within the same card.
	   - for rest of the prtExVcPbxTsMode values, the value will be: noConnect.   
       This object indicates whether the specified compressed/transparent
       time slot is connected/routed internally in the Agent and
       to which card it is connected.
       For VF-PBX card, the valid selectable slots are either the current one,
       (prtExVcPbxTsSltIdx), or a slot containing a VF-PBX card.
       In the ?004 Unit the entries io6(10)..io12(16) are not valid."
      ::= {prtExVcPbxTsEntry 6}

prtExVcPbxTsIConPrt OBJECT-TYPE
      SYNTAX  INTEGER
       {
       exPrt1      (1),
       exPrt2      (2),
	   exPrt3      (3),
	   exPrt4      (4),
	   exPrt5      (5),
	   exPrt6      (6),
	   exPrt7      (7),
	   exPrt8      (8),
       noConnect (100),
       inPrt1    (101),
       inPrt2    (102),
       inPrt3    (103),
       inPrt4    (104),
       inPrt5    (105),
       inPrt6    (106),
	   inPrt7    (107),
	   inPrt8    (108)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the port to which this TS is connected.
	   For VF-PBX cards, only inPrt1..inPrt6 ports are valid.
	   For VF-24/30/48/60 cards:
	       - for prtExVcPbxTsMode=transparent or voiceTransparent, the valid ports are
		     ML ports (exPrt1.. exPrt8, inPrt1.. inPrt8)
	       - for prtExVcPbxTsMode=compressed or compressedCcs, the valid 
	         ports are internal ports of the same card (inPrt1..inPrt8)
       noConnect - when prtExVcPbxTsIConSlot=noConnect."
      ::= {prtExVcPbxTsEntry 7}

prtExVcPbxTsIConTs OBJECT-TYPE
      SYNTAX  Integer32	(1..255)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the ML TS to which this TS is connected.
	   This object is not applicable for VF-PBX cards.
	   For VF-24/30/48/60 cards it is applicable only when 
	   prtExVcPbxTsMode=transparent or voiceTransparent.
       The valid time slots are 1..24 for ML T1 cards and 1..31 for ML E1 cards.
       notApplicable - 255. "
      ::= { prtExVcPbxTsEntry 8}

prtExVcPbxTsRemPrt OBJECT-TYPE
      SYNTAX  INTEGER
      {
          exPrt1    (1),
		  exPrt2    (2),
          noConnect (100)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the end-point port on the Remote unit.
	   VF-24/T1 and VF-30/E1 cards have one external interface.
       VF-48/T1 and VF-60/E1 cards have two external interfaces.
       noConnect - when prtExVcPbxTsMode=unused, transparent, voiceTransparent or mng."
      ::= { prtExVcPbxTsEntry 9}

prtExVcPbxTsRemTs OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the end-point TS on the Remote unit.
       The valid time slots are 1..24 for T1 ports and 1..31 for E1 ports.
       notApplicable - 255."
      ::= { prtExVcPbxTsEntry 10}

prtExVcPbxTsRemConnID OBJECT-TYPE
      SYNTAX  Unsigned32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Connection ID with the Remote unit.
       notApplicable = 0."
      ::= { prtExVcPbxTsEntry 11}

prtExVcPbxTsSourceSlot OBJECT-TYPE
      SYNTAX  INTEGER
       {
          noConnect (2),
          io1       (5),
          io2       (6),
          io3       (7),
          io4       (8),
          io5       (9),
          io6      (10),
          io7      (11),
          io8      (12),
          io9      (13),
          io10     (14),
          io11     (15),
          io12     (16)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "For VFS cards. These cards offer Compresed Voice Services for 
	   Analog Voice ports of the MP.
	   This object indicates the Source Slot of the Analog Voice port we want 
	   to compress.
       io1..io12 values are applicable only when prtExVcPbxTsMode=compressed(voice). 
       Otherwise, its value should be noConnect.
       In the ?004 Unit the entries io6(10)..io12(16) are not valid."
      ::= {prtExVcPbxTsEntry 12}

prtExVcPbxTsSourcePrt OBJECT-TYPE
      SYNTAX  Unsigned32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "For VFS cards. These cards offer Compresed Voice Services for 
	   Analog Voice ports of the MP.
       This object indicates the Source Port within the Slot of the Analog Voice Card, 
       we want to compress.
	   exPrt1 - exPrt16 = 1 - 16
       noConnect=100 - when prtExVcPbxTsCvServiceSlot=noConnect."
      ::= {prtExVcPbxTsEntry 13}

-- The following tables contains information specific to
-- the isdn access modules

prtIsdnCnfgTable OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtIsdnCnfgEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
       "The write operation into the table objects is valid only
        to the TmpCnfg entry."
      ::= { prtIsdnCnfg 1}

prtIsdnCnfgEntry OBJECT-TYPE
      SYNTAX PrtIsdnCnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtIsdnCnfgIdx, prtIsdnSltIdx, prtIsdnPrtIdx}
      ::= { prtIsdnCnfgTable 1}

PrtIsdnCnfgEntry ::=
      SEQUENCE {
      prtIsdnCnfgIdx           Integer32,
      prtIsdnSltIdx            INTEGER,
      prtIsdnPrtIdx            Integer32,
      prtIsdnConnect           INTEGER,
      prtIsdnSignalingProtocol      INTEGER,
      prtIsdnBasicRateLineTopology  INTEGER,
      prtIsdnMode              INTEGER,
      prtIsdnFilter            INTEGER,
      prtIsdnSimultaneousCall  INTEGER,
      prtIsdnNumOfAbstractTerm Integer32,
      prtIsdnSwitchMode        INTEGER,
	  prtIsdnAbSide            INTEGER,
	  prtIsdnQsigRole          INTEGER,
	  prtIsdnInterface         INTEGER,
	  prtIsdnCallMode          INTEGER,
	  prtIsdnCallBackTimeout   Integer32
        }

prtIsdnCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32  (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg. "
      ::= { prtIsdnCnfgEntry 1}

prtIsdnSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
            {
              io1  (5),
              io2  (6),
              io3  (7),
              io4  (8),
              io5  (9),
              io6 (10),
              io7 (11),
              io8 (12),
              io9 (13),
              io10(14),
              io11(15),
              io12(16),
              kmxMlA (103),
              kmxMlB (104),
              notApplicable(255)
            }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted.
       In the ?004 Unit the entries io6(10)..io12(16) are not valid
       For KM2100/4 Valid entries are 'kmxMlA ' or 'kmxMlB'"
      ::= { prtIsdnCnfgEntry 2}

prtIsdnPrtIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  port number.
       For MAXcess the values will be:
          exPrt1(1),
          exPrt2(2),
          exPrt3(3),
          exPrt4(4),
       For KM-2100 the port index is calculated as follows:
       100*Slot+Ch"
       ::= { prtIsdnCnfgEntry 3}

prtIsdnConnect OBJECT-TYPE
      SYNTAX  INTEGER { no(2), yes(3) }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates if the port is connected."
      ::= { prtIsdnCnfgEntry 4 }

prtIsdnSignalingProtocol OBJECT-TYPE
      SYNTAX  INTEGER
      {
        other(1), etsi(3), ess4(5), ess5(6), dms100(7), 
        ni1(9), ni2(10), ins64(17), ins1500(18), qsig(21),
        notApplicable(255)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute fixes which signaling protocol
        is used at this port (D-Channel).
        It is equivalent to isdnSignalingProtocol
        in the isdn MIB."
      DEFVAL { etsi }
      ::= { prtIsdnCnfgEntry 5 }

prtIsdnBasicRateLineTopology OBJECT-TYPE
      SYNTAX  INTEGER
      {
        pointToPoint(1),
        pointToMultipoint(2),
        notApplicable(255)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute is relevant for ISDN BRI only.
        It is equivalent to isdnBasicRateLineTopology
        in the isdn MIB."
      ::= { prtIsdnCnfgEntry 6 }

prtIsdnMode OBJECT-TYPE
      SYNTAX  INTEGER
      {
        dialup(1),
        leased(2),
		syncLeased(3),
        notApplicable(255)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute allows the user to configure the port as
       leased(2) in case of connection to a TDM network."
      ::= { prtIsdnCnfgEntry 7}

prtIsdnFilter OBJECT-TYPE
      SYNTAX  INTEGER
      { notApplicable(1),
        answerAll(2),
        rejectAll(3),
        selective(4),
		callBack (5)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute allows the user to configure the port:
       answerAll(2): accept all incoming calls,
       rejectAll(3): reject all incoming calls,
       selective(4): accept or reject according directory table.
       callBack (5): In this mode the ISDN Ch will reject incoming calls
       and will initiate call back to the rejected phone number."
      ::= { prtIsdnCnfgEntry 8}

prtIsdnSimultaneousCall OBJECT-TYPE
      SYNTAX  INTEGER
      { notApplicable(1),
 accept(2), reject(3) }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "In case of simultaneous call (local,remote and remote,local):
       accept(2): accept the incoming call,
       reject(3): reject the incoming call."
      ::= { prtIsdnCnfgEntry 9}

prtIsdnNumOfAbstractTerm OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "An object for KM2100/4 agents.
    255=Not Applicable
       When ISDN Standard = ETSI or NTT (European) the value should be 255 (NotApplicable)
       else If ML speed is 64Kbps value should be 1.
       If ML speed is 128Kbps value can be either 1 or 2 (user selection)."
      ::= { prtIsdnCnfgEntry 10}

prtIsdnSwitchMode OBJECT-TYPE
      SYNTAX  INTEGER
      {
        notApplicable(1),
        auto   (2),
        manual (3),
		connect(4)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "For KM2100.
       auto   - The call is initiated automatically by one of the IO cards connected
                to KML.10(ISDN card) having ISDN Switch Mode.
       manual - The call is initiated by the user manually,  for KML.10
                having ISDN Switch Mode (via mdlSCmd).
       connect- The call is initiated 'immediately', for KML.10 having ISDN Switch Mode.
                'immediately'- means: immediately after power-up (when product performed
                                      Reset) OR, since this value appears in the active
                 					  configuration.
                In this case, the call can be disconnected only by power-off of the
                product or by changing this object to another value (or actual Remove
                of the KML.10 relevant card).
       notApplicable - For other card types."
      ::= { prtIsdnCnfgEntry 11}

prtIsdnAbSide OBJECT-TYPE
      SYNTAX  INTEGER
      {
        notApplicable(1),
        aSide (2),
        bSide (3)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This parameter indicates the QSIG side in layer 3.
       This definition is from the QSIG Standard."
      ::= { prtIsdnCnfgEntry 12}

prtIsdnQsigRole OBJECT-TYPE
      SYNTAX  INTEGER
      {
        notApplicable(1),
        slave    (2),
        master   (3)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This parameter indicates the QSIG side in layer 1 & 2."
      ::= { prtIsdnCnfgEntry 13}

prtIsdnInterface  OBJECT-TYPE
      SYNTAX  INTEGER
       {
       lt   (1),
       nt   (2),
       te   (3),
       notApplicable (255)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "It indicates the interface type:
       lt = line termination
       nt = network termination
       te = terminal equipment."
      ::= { prtIsdnCnfgEntry 14}

prtIsdnCallMode     OBJECT-TYPE
      SYNTAX  INTEGER  { 
                 notApplicable(1), 
                 initiate     (2), 
                 listen       (3) 
                 }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the acceptance of incoming calls.
       Initiate - Callout
       Listen   - Callin. "
      ::= { prtIsdnCnfgEntry 15}


prtIsdnCallBackTimeout  OBJECT-TYPE
      SYNTAX  Integer32 
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object is applicable only if 'prtIsdnFilter' is 'CallBack'
       and determines how long to wait from receiving the incoming call
       until initiating the call back call.
       The vaules range should be '1..20 sec' and the default 10 sec."
      ::= { prtIsdnCnfgEntry 16}



prtIsdnEndpointTable OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtIsdnEndpointEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
       "The write operation into the table objects is valid only
        to the TmpCnfg entry."
      ::= { prtIsdnCnfg 2}

prtIsdnEndpointEntry OBJECT-TYPE
      SYNTAX PrtIsdnEndpointEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtIsdnEndpointCnfgIdx, prtIsdnEndpointSltIdx,
        prtIsdnEndpointPrtIdx, prtIsdnEndpointIdx }
      ::= { prtIsdnEndpointTable 1}

PrtIsdnEndpointEntry ::=
      SEQUENCE {
      prtIsdnEndpointCnfgIdx        Integer32,
      prtIsdnEndpointSltIdx         INTEGER,
      prtIsdnEndpointPrtIdx         Integer32,
      prtIsdnEndpointIdx            INTEGER,
      prtIsdnEndpointTeiType        INTEGER,
      prtIsdnEndpointTeiValue       Integer32,
      prtIsdnEndpointSpid           DisplayString,
	  prtIsdnEndpointBearerCh       INTEGER,
      prtIsdnEndpointRowStatus      RowStatus
        }

prtIsdnEndpointCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32  (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg. "
      ::= { prtIsdnEndpointEntry 1}

prtIsdnEndpointSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
            {
              io1(5),
              io2(6),
              io3(7),
              io4(8),
              io5(9),
              io6(10),
              io7(11),
              io8(12),
              io9(13),
              io10(14),
              io11(15),
              io12(16),
              kmxMlA (103),
              kmxMlB (104),
              notApplicable(255)
            }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted.
       In ?004 Unit the entries io6(10)..io12(16) are not valid
       For KM2100/4 Valid entries are 'kmxMlA ' or 'kmxMlB'"
      ::= { prtIsdnEndpointEntry 2}

prtIsdnEndpointPrtIdx OBJECT-TYPE
        SYNTAX  Integer32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
       "This attribute indicates a unique  port number.
         For MAXcess the values will be:
          exPrt1(1),
          exPrt2(2),
          exPrt3(3),
          exPrt4(4),
         For KM-2100 the port index is calculated as follows:
         100*Slot+Ch"
       ::= { prtIsdnEndpointEntry 3}

prtIsdnEndpointIdx OBJECT-TYPE
        SYNTAX  INTEGER { atei1(1), atei2(2) }
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
        "Since more than one endpoint may be defined per
        isdn entity, this field is a simple index.
        It corresponds to isdnEndpointIdx in the isdn MIB."
--         DEFVAL { atei1 }
        ::= { prtIsdnEndpointEntry 4}

prtIsdnEndpointTeiType OBJECT-TYPE
        SYNTAX  INTEGER { dynamic(1), static(2), notApplicable(255) }
        MAX-ACCESS read-create
        STATUS current
        DESCRIPTION
        "The type of TEI (Terminal Endpoint Identifier)
             used for this Terminal Endpoint. In case of dynamic(1),
             the TEI value is selected by the switch. In
             case of static(2), a valid TEI value has to be
             entered in the isdnEndpointTeiValue object.
             interface type as well as the Terminal Endpoint type.
             static(2). On Basic Rate interfaces the default value
             is dynamic(1) for isdn(63) Terminal Endpoints.
        It corresponds to isdnEndpointTeiType in the isdn MIB."
        ::= { prtIsdnEndpointEntry 5}

prtIsdnEndpointTeiValue OBJECT-TYPE
        SYNTAX  Integer32
        MAX-ACCESS read-create
        STATUS current
        DESCRIPTION
        "When the TEI Type is static, the value of the TEI should be
         between 0 and 63. Else, it is not selectable by user.
		 255 = notApplicable.
         It corresponds to isdnEndpointTeiValue in the isdn MIB"
        ::= { prtIsdnEndpointEntry 6 }

prtIsdnEndpointSpid OBJECT-TYPE
        SYNTAX  DisplayString
        MAX-ACCESS read-create
        STATUS current
        DESCRIPTION
        "The Service profile IDentifier (SPID) information
         for this Terminal Endpoint. It is is composed of
         9-20 numeric characters.
        It corresponds to isdnEndpointSpid in the isdn MIB."
        ::= { prtIsdnEndpointEntry 7 }

prtIsdnEndpointBearerCh OBJECT-TYPE
        SYNTAX  INTEGER {
                notApplicable(1),
                anyChannel (2),
                channelB1  (3),
                channelB2  (4) }
        MAX-ACCESS read-create
        STATUS current
        DESCRIPTION
        "This is the selected dialing channel.
         anyChannel - the system selects the dialing channel."
        ::= { prtIsdnEndpointEntry 8}

prtIsdnEndpointRowStatus OBJECT-TYPE
        SYNTAX  RowStatus
        MAX-ACCESS read-create
        STATUS current
        DESCRIPTION
        "This field indicates whether to consider this endpoint or not.
         The only possible supported RowStatus vaules are
         active (1) and destroy (6)."
        ::= { prtIsdnEndpointEntry 9}

prtIsdnDirectoryTable OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtIsdnDirectoryEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
       "The write operation into the table objects is valid only
        to the TmpCnfg entry."
      ::= { prtIsdnCnfg 3}

prtIsdnDirectoryEntry OBJECT-TYPE
      SYNTAX PrtIsdnDirectoryEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX { prtIsdnDirectoryCnfgIdx, prtIsdnDirectorySltIdx, prtIsdnDirectoryPrtIdx }
      ::= { prtIsdnDirectoryTable 1}

PrtIsdnDirectoryEntry ::=
      SEQUENCE {
      prtIsdnDirectoryCnfgIdx   Integer32,
      prtIsdnDirectorySltIdx         INTEGER,
      prtIsdnDirectoryPrtIdx         Integer32,
      prtIsdnDirectoryLocalAddr    DisplayString,
      prtIsdnDirectoryLocalSubAddr   DisplayString,
      prtIsdnDirectoryRemoteAddr    DisplayString,
      prtIsdnDirectoryRemoteSubAddr  DisplayString,
      prtIsdnDirectoryPrtNu          Integer32,
      prtIsdnDirectoryTeiId          Integer32,
      prtIsdnDirectoryRowStatus      RowStatus,
      prtIsdnDirectoryLocalAddr2     DisplayString,
      prtIsdnDirectoryLocalSubAddr2  DisplayString,
      prtIsdnDirectoryRemoteAddr2    DisplayString,
      prtIsdnDirectoryRemoteSubAddr2 DisplayString
      }

prtIsdnDirectoryCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32  (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg. "
      ::= { prtIsdnDirectoryEntry 1}

prtIsdnDirectorySltIdx OBJECT-TYPE
      SYNTAX  INTEGER
            {
              io1(5),
              io2(6),
              io3(7),
              io4(8),
              io5(9),
              io6(10),
              io7(11),
              io8(12),
              io9(13),
              io10(14),
              io11(15),
              io12(16),
              kmxMlA (103),
              kmxMlB (104),
			  notApplicable (255)
            }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the card is inserted.
       For MX300/30 ports:
       io1(5) = isdn1(5) and io2(6) = isdn2(6).
       In ?004 Unit the entries io6(10)..io12(16) are not valid
       For KM2100/4 Valid entries are 'kmxMlA ' or 'kmxMlB'"
      ::= { prtIsdnDirectoryEntry 2}

prtIsdnDirectoryPrtIdx OBJECT-TYPE
        SYNTAX  Integer32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
        "For MAXcess this is the internal port number: 101, 102,....
         For KM-2100 the port index is calculated as follows:
         100*Slot+Ch"
        ::= { prtIsdnDirectoryEntry 3}

prtIsdnDirectoryLocalAddr OBJECT-TYPE
        SYNTAX DisplayString (SIZE(17..20))
        MAX-ACCESS read-create
        STATUS current
        DESCRIPTION
        "This is the local address associated with this
         entry.
         - For MX: Size=17 , Default=0	(17 characters)
         - For KM: Size=20, Default=blank (20 characters) "
        ::= { prtIsdnDirectoryEntry 4}

prtIsdnDirectoryLocalSubAddr OBJECT-TYPE
        SYNTAX DisplayString (SIZE(4..6))
        MAX-ACCESS read-create
        STATUS current
        DESCRIPTION
        "This is the local subaddress associated with this
         entry.
         - For MX: Size=6 , Default=0	(6 characters)
         - For KM: Size=4 , Default=blank (4 characters)"
        ::= { prtIsdnDirectoryEntry 5}

prtIsdnDirectoryRemoteAddr OBJECT-TYPE
        SYNTAX DisplayString (SIZE(17..20))
        MAX-ACCESS read-create
        STATUS current
        DESCRIPTION
        "This is the remote address associated with this
         entry.
         - For MX: Size=17 , Default=0	(17 characters)
         - For KM: Size=20, Default=blank (20 characters)"
        ::= { prtIsdnDirectoryEntry 6}

prtIsdnDirectoryRemoteSubAddr OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(4..6))
        MAX-ACCESS read-create
        STATUS current
        DESCRIPTION
        "This is the remote subaddress associated with this
         entry.
         - For MX: Size=6 , Default=0 (6 characters)
         - For KM: Size=4 , Default=blank (4 characters)"
        ::= { prtIsdnDirectoryEntry 7}


prtIsdnDirectoryPrtNu OBJECT-TYPE
        SYNTAX  Integer32
        MAX-ACCESS read-create
        STATUS current
        DESCRIPTION
        "This is the external port number connected to
         this entry."
         DEFVAL { 1 }
        ::= { prtIsdnDirectoryEntry 8}

prtIsdnDirectoryTeiId OBJECT-TYPE
        SYNTAX  Integer32
        MAX-ACCESS read-create
        STATUS current
        DESCRIPTION
        "This is the abstract terminal id if relevant,
        connected to this entry."
        DEFVAL { 1 }
        ::= { prtIsdnDirectoryEntry 9}

prtIsdnDirectoryRowStatus OBJECT-TYPE
        SYNTAX  RowStatus
        MAX-ACCESS read-create
        STATUS current
        DESCRIPTION
        "This is the status for the row. It allows to know
        whether to consider this row or not.
        The only possible supported RowStatus vaules are
        active (1) and destroy (6)."
        ::= { prtIsdnDirectoryEntry 10}

prtIsdnDirectoryLocalAddr2 OBJECT-TYPE
        SYNTAX DisplayString (SIZE(17..20))
        MAX-ACCESS read-create
        STATUS current
        DESCRIPTION
        "This is the second local address associated with this
         entry.
         - For MX: Size=17 , Default=0 (17 characters)
         - For KM: Size=20, Default=blank (20 characters)"
        ::= { prtIsdnDirectoryEntry 11}

prtIsdnDirectoryLocalSubAddr2 OBJECT-TYPE
        SYNTAX DisplayString (SIZE(4..6))
        MAX-ACCESS read-create
        STATUS current
        DESCRIPTION
        "This is the second local subaddress associated with this
         entry.
         - For MX: Size=6 , Default=0 (6 characters)
         - For KM: Size=4 , Default=blank (4 characters)"
        ::= { prtIsdnDirectoryEntry 12}

prtIsdnDirectoryRemoteAddr2 OBJECT-TYPE
        SYNTAX DisplayString (SIZE(17..20))
        MAX-ACCESS read-create
        STATUS current
        DESCRIPTION
        "This is the second remote address associated with this
         entry.
         - For MX: Size=17 , Default=0 (17 characters)
         - For KM: Size=20, Default=blank(20 characters) "
        ::= { prtIsdnDirectoryEntry 13}

prtIsdnDirectoryRemoteSubAddr2 OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(4..6))
        MAX-ACCESS read-create
        STATUS current
        DESCRIPTION
        "This is the second remote subaddress associated with this
         entry.
         - For MX: Size=6 , Default=0 (6 characters)
         - For KM: Size=4 , Default=blank (4 characters) "
        ::= { prtIsdnDirectoryEntry 14}



-- This table is an extension for new version of MAXcess
-- modules.
prtFrPlusCnfgTable  OBJECT-TYPE
     SYNTAX SEQUENCE OF PrtFrPlusCnfgEntry
     MAX-ACCESS not-accessible
     STATUS  current
     DESCRIPTION
      "The write operation into the Table Objects is valid only
       to the TmpCnfg entry."
     ::= {prtFrPlusCnfg 1}

prtFrPlusCnfgEntry OBJECT-TYPE
      SYNTAX PrtFrPlusCnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtFrPlusCnfgIdx, prtFrPlusSltIdx, prtFrPlusPrtIdx }
      ::= { prtFrPlusCnfgTable 1}

PrtFrPlusCnfgEntry ::=
      SEQUENCE {
      prtFrPlusCnfgIdx   Integer32,
      prtFrPlusSltIdx    INTEGER,
      prtFrPlusPrtIdx   Integer32,
      prtFrPlusNotSegmentedPriorities  OCTET STRING
}

prtFrPlusCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg. "
      ::= { prtFrPlusCnfgEntry 1}

prtFrPlusSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
            {
              io1   (5),
              io2   (6),
              io3   (7),
              io4   (8),
              io5   (9),
              io6  (10),
              io7  (11),
              io8  (12),
              io9  (13),
              io10 (14),
              io11 (15),
              io12 (16),
       notApplicable(255)
            }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
        "Slot Index.
         For ISDN BRI Ports of MX300/30,
    io1(5) = isdn1(5) and io2(6) = isdn2(6)."
      ::= { prtFrPlusCnfgEntry 2}

prtFrPlusPrtIdx  OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  port number.
       This port number should be:
       - for ISDN cards: inPrt1(101)->inPrt50(150)
       - for MHS1 card : exPrt1(1)
       - for MHS3, MLS3 cards: exPrt1(1)->exPrt3(3)
       - for MLS6 cards: exPrt1(1)->exPrt6(6)."
      ::= { prtFrPlusCnfgEntry 3}

prtFrPlusNotSegmentedPriorities OBJECT-TYPE
       SYNTAX OCTET STRING(SIZE(1))
       MAX-ACCESS   read-write
       STATUS   current
       DESCRIPTION
      "This parameter is relevant only for FR+ protocol and
       asks the MXcess NOT to segment data with specified
       priorities:  from LSB:
       bit 1  is for priority 1,
       bit 2  is for priority 2, .... till bit 7 for priority 7.
	   - a priority selected to be segmented : its bit will be '0'
	   - a priority not to be segmented : its bit will be '1'
       Default is 00000000; i.e, segment all priorities."
     DEFVAL { '00'H }
     ::= { prtFrPlusCnfgEntry 4 }


-- This table is an extension of prtExPh1MlCnfgTable for MTML cards
-- of MP-2200 and MP-2100

    prtMl4CnfgTable  OBJECT-TYPE
     SYNTAX SEQUENCE OF PrtMl4CnfgEntry
     MAX-ACCESS not-accessible
     STATUS  current
     DESCRIPTION
      "This is an extension table for MTML-4 card parameters."
     ::= {prtMl4Cnfg 1}

prtMl4CnfgEntry OBJECT-TYPE
      SYNTAX PrtMl4CnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtMl4CnfgIdx, prtMl4SltIdx, prtMl4PrtIdx }
      ::= { prtMl4CnfgTable 1}

PrtMl4CnfgEntry ::=
      SEQUENCE {
      prtMl4CnfgIdx              Integer32,
      prtMl4SltIdx               INTEGER,
      prtMl4PrtIdx               INTEGER,
      prtMl4SigProfile           INTEGER,
      prtMl4CGA                  INTEGER,
      prtMl4Oos                  INTEGER,
      prtMl4VoiceOos             OCTET STRING,
      prtMl4DataOos              OCTET STRING,
	  prtMl4Service              INTEGER,
	  prtMl4IpAddress            IpAddress,
	  prtMl4IpMask               IpAddress,
	  prtMl4SignalingMode        INTEGER,
	  prtMl4EchoCanceler         INTEGER,
	  prtMl4OosErrorSource       INTEGER,
	  prtMl4OosEntryThreshold    Integer32,
	  prtMl4OosExitThreshold     Integer32,
	  prtMl4LogicalLinkId        Integer32,
	  prtMl4DedicatedTs          Integer32,
	  prtMl4RemCrc               INTEGER,
	  prtMl4CrossConnectLevel    INTEGER,
	  prtMl4PppEchoFailDetection INTEGER,
	  prtMl4EcanCasControl       INTEGER
      }


prtMl4CnfgIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg. The write operation is valid only
       to the TmpCnfg."
      ::= { prtMl4CnfgEntry 1}

prtMl4SltIdx OBJECT-TYPE
      SYNTAX  INTEGER
     {
       clA   (3),
       clB   (4),
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
	   notApplicable (255)
     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the module is inserted."
      ::= { prtMl4CnfgEntry 2}

prtMl4PrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
       {
       exPrt1    (1),
       exPrt2    (2),
       exPrt3    (3),
       exPrt4    (4),
       exPrt5    (5),
       exPrt6    (6),
       exPrt7    (7),
       exPrt8    (8),
       inPrt1  (101),
       inPrt2  (102),
       inPrt3  (103),
       inPrt4  (104),
       inPrt5  (105),
       inPrt6  (106),
       inPrt7  (107),
       inPrt8  (108),
       inPrt9   (109),
       inPrt10  (110),
       inPrt11  (111),
       inPrt12  (112),
       inPrt13  (113),
       inPrt14  (114),
       inPrt15  (115),
       inPrt16  (116),
       inPrt17  (117),
       inPrt18  (118),
       inPrt19  (119),
       inPrt20  (120),
       inPrt21  (121),
       inPrt22  (122),
       inPrt23  (123),
       inPrt24  (124),
       inPrt25  (125),
       inPrt26  (126),
       inPrt27  (127),
       inPrt28  (128),
       inPrt29  (129),
       inPrt30  (130),
       inPrt31  (131),
       inPrt32  (132),
       inPrt33  (133),
       inPrt34  (134),
       inPrt35  (135),
       inPrt36  (136),
       inPrt37  (137),
       inPrt38  (138),
       inPrt39  (139),
       inPrt40  (140),
       inPrt41  (141),
       inPrt42  (142),
       inPrt43  (143),
       inPrt44  (144),
       inPrt45  (145),
       inPrt46  (146),
       inPrt47  (147),
       inPrt48  (148),
       inPrt49  (149),
       inPrt50  (150),
       inPrt51  (151),
       inPrt52  (152),
       inPrt53  (153),
       inPrt54  (154),
       inPrt55  (155),
       inPrt56  (156),
       inPrt57  (157),
       inPrt58  (158),
       inPrt59  (159),
       inPrt60  (160),
       inPrt61  (161),
       inPrt62  (162),
       inPrt63  (163),
       inPrt64  (164),
       inPrt65  (165),
       inPrt66  (166),
       inPrt67  (167),
       inPrt68  (168),
       inPrt69  (169),
       inPrt70  (170),
       inPrt71  (171),
       inPrt72  (172),
       inPrt73  (173),
       inPrt74  (174),
       inPrt75  (175),
       inPrt76  (176),
       inPrt77  (177),
       inPrt78  (178),
       inPrt79  (179),
       inPrt80  (180),
       inPrt81  (181),
       inPrt82  (182),
       inPrt83  (183),
       inPrt84  (184)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  port number."
      ::= { prtMl4CnfgEntry 3}

prtMl4SigProfile OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable (1),
       none          (2),
       p1            (3),
       p2            (4),
       p3            (5),
       p4            (6),
       p5            (7),
	   perTS         (8) 
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the Signaling Profile of the port.
       none - when the Frame is G732N (no MF) or Unframed.
       p1  = profile 1
       p2  = profile 2
       p3  = profile 3
       p4  = profile 4
       p5  = profile 5 
       perTS = when Signaling Profile is selected per TS."
	  ::= {prtMl4CnfgEntry 4}

prtMl4CGA OBJECT-TYPE
    SYNTAX  INTEGER {
      none (1),
      trans(2),
      full (3)
            }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "This object selects the method used to signal the CGA state
     to the other end, through the main link.
     'none'  - non-transparent mode. When one of the links
               (main) will be in Out Of Service state, both
               'Data/Voice Oos' and 'Oos' will be
               transmitted to the other end.
     'trans' - when one of the links (main) will be in Out
               Of Service state, 'Data/Voice Oos' will be
               transmitted to the other end.
     'full'  - fully-transparent mode. When one of the links
                  (main) will be in Out Of Service state,
                  neither 'Data/Voice Oos' nor 'Oos' will
                  be transmitted to the other end."
 ::= { prtMl4CnfgEntry 5 }

prtMl4Oos  OBJECT-TYPE
      SYNTAX  INTEGER
       {
        notSupported  (2),
        forcedIdle    (3),
        forcedBusy    (4),
        busyIdle      (5),
        idleBusy      (6)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "'idle' = '0' = on-hook, idle state
       'busy' = '1' = off-hook, busy state
       'forcedIdle' = SP = both A and B signaling bits are forced
                      to '0' during out-of-service periods.
       'forcedBusy' = MK = both A and B signaling bits are forced
                      to '1' during out-of-service periods.
       'busyIdle'   = MK_SP = A and B bits are forced to '1' for
                      2.5 seconds; then they are switched to '0'
                      until out-of-service condition disappears.
       'idleBusy'   = SP_MK = A and B bits are forced to '0' for
                      2.5 seconds; then they are switched to '1'
                      until out-of-service condition disappears.
       - for T1:    '0'=0   ;  '1'=1
       - for E1:    '0'=1   ;  '1'=0   "
   ::= { prtMl4CnfgEntry 6 }

prtMl4VoiceOos  OBJECT-TYPE
 SYNTAX  OCTET STRING (SIZE (0..4))
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "Voice Out-Of-Service code. Valid range: (0 - FF HEX).
     For agents that do not support this feature, the value will
     always be 0."
   ::= { prtMl4CnfgEntry 7 }

prtMl4DataOos  OBJECT-TYPE
 SYNTAX  OCTET STRING (SIZE (0..4))
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "Data Out-Of-Service code. Valid range: (0 - FF HEX).
     For agents that do not support this feature, the value will
     always be 0."
   ::= { prtMl4CnfgEntry 8 }

prtMl4Service OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable (1),
       leasedLine    (2),
       v51           (3),
	   v52Master     (4),
	   v52Slave      (5)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Link Service.
       leasedLine - usual TDM interface.
       v51        - V5.1 interface.
       v52Master  - V5.2 Link to Local Exchange.
       v52Slave   - a ML that is transferred to the v52Master."
      ::= {prtMl4CnfgEntry 9}

prtMl4IpAddress OBJECT-TYPE
      SYNTAX  IpAddress
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "IP Address of the port."
      ::= {prtMl4CnfgEntry 10}

prtMl4IpMask OBJECT-TYPE
      SYNTAX  IpAddress
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "IP subnet mask of the port."
      ::= {prtMl4CnfgEntry 11}

prtMl4SignalingMode OBJECT-TYPE
      SYNTAX INTEGER { notApplicable(1),
		cas(2),
		ccs(3),
		robbedBit(4),
		other (5)
		}
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
      "Refers to the signaling mode of the port (or framer module).
	  notApplicable(1)- means that no framer is needed for this port (no signaling),
	         or that this object is not relevant.
      cas(2) means Channel Associated Signaling. Used for E1 Links.
      ccs(3) is the Common Channel Signaling (the signaling is not within
             the channels time slot - a TS for signaling is used).
      robbedBit(4) is a method implementing 7 bits for the voice and 1 bit
                   dedicated for signaling. Used for T1 Links.
      other (5)- Signaling generally exists though not specifically according
              to one of the values listed ; this port uses a framer in this case."
      ::= {prtMl4CnfgEntry 12}

prtMl4EchoCanceler OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable (1),
       off    (2),
       on     (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Echo canceler activation."
      ::= {prtMl4CnfgEntry 13}

prtMl4OosErrorSource OBJECT-TYPE
      SYNTAX  INTEGER
       {
       notApplicable (1),
       none          (2),
       framing       (3),
	   bpv		     (4)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "OOS (Out-of-Service) Error Source.
       This object is applicable for T1 ports only."
      ::= {prtMl4CnfgEntry 14}

prtMl4OosEntryThreshold OBJECT-TYPE
      SYNTAX  Integer32 (0..999)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object defines the number of Errors per Second that determine the 
       minimum unacceptable noise level. This value will be the Entry Threshold
       to the OOS (Out-of-Service) state.
       This object is applicable only when prtMl4OosErrorSource=framing(3) or bpv(4).
       0=notApplicable."
      ::= { prtMl4CnfgEntry 15}

prtMl4OosExitThreshold OBJECT-TYPE
      SYNTAX  Integer32 (0..99)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object defines the number of consecutive Error-Free-Seconds before
       going from OOS state to Normal state. This value will be the Exit Threshold
       from the OOS (Out-of-Service) state.
	   Units=seconds
       This object is applicable only when prtMl4OosErrorSource=framing(3) or bpv(4).
       0=notApplicable."
      ::= { prtMl4CnfgEntry 16}

prtMl4LogicalLinkId OBJECT-TYPE
      SYNTAX  Integer32 (0..257)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object defines for a V5.2 Master ML the Logical Link Id.
       Valid values are: 0..256.
       NA=257."
      ::= { prtMl4CnfgEntry 17}

prtMl4DedicatedTs OBJECT-TYPE
      SYNTAX  Integer32 (1..255)
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "A unique number to identify Dedicated TS of the E1 port (V5.2).
       It is applicable only when prtMl4Service=v52Slave and 
       prtExPh1MlInbandMng selected is dedicatedTs, dedicatedPpp or dedicatedFr.
       1..31 - Dedicated TS of E1
       255   - notApplicable 
       Other values are invalid."
      ::= { prtMl4CnfgEntry 18}

prtMl4RemCrc OBJECT-TYPE
      SYNTAX  INTEGER 
       {
        notApplicable	(1), 
        no              (2),
        yes             (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates whether the E1 of the Remote device
       connected to this E1 port, will have CRC-4 or not."
      ::= { prtMl4CnfgEntry 19 }

prtMl4CrossConnectLevel OBJECT-TYPE
      SYNTAX  INTEGER 
       {
        notApplicable	(1), 
        ds0             (2),
        ds1             (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates whether the cross connect is 
       on DS1 or DS0 (time-slots) level.  
       When cross connect level is ds1, Destination Slot 
       is indicated by prtGenCnfgLinkToSlot,
       Destination Port is indicated by prtGenCnfgLinkToPort. 
       For Unframed Line Type, cross connect level can be either
       notApplicable (NC=not connected) or DS1.
       Otherwise, default value is ds0."
      ::= { prtMl4CnfgEntry 20 }

prtMl4PppEchoFailDetection  OBJECT-TYPE
      SYNTAX  INTEGER 
       {
        notApplicable	(1), 
        disable         (2),
        enable          (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates whether the PPP Echo is taken into account
       for its Fail Detection.  
       This object is relevant when Inband Mng between devices is Dedicated TS PPP.
       Default=Disable.
	   Enable - will be selected mainly when a T1/E1 Ring exists and between 2 adjacent 
	            Ring devices there is another device or Net, that causes these Ring devices
	            not to sense that the PPP connection between them is lost. In this case,
	            Echo Request should be initiated by the port."
      ::= { prtMl4CnfgEntry 21 }

prtMl4EcanCasControl OBJECT-TYPE
      SYNTAX  INTEGER 
       {
        notApplicable	(1), 
        disable         (2),
        enable          (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object enables/disables ECAN (Echo Canceller) control activation/deactivation
       sent via the A, B, C, D multiframe signaling BITs."
	  ::= { prtMl4CnfgEntry 22 }				 


--prtAcmCnfgTable defines the parameters of the
--ACM cards family external ports 1-8

prtAcmCnfgTable  OBJECT-TYPE
     SYNTAX SEQUENCE OF PrtAcmCnfgEntry
     MAX-ACCESS not-accessible
     STATUS  current
     DESCRIPTION
      "This is a table for ACM port parameters."
     ::= {prtAcmCnfg 1}

prtAcmCnfgEntry OBJECT-TYPE
      SYNTAX PrtAcmCnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtAcmCnfgIdx, prtAcmSltIdx, prtAcmPrtIdx }
      ::= { prtAcmCnfgTable 1}

PrtAcmCnfgEntry ::=
      SEQUENCE {
      prtAcmCnfgIdx        Integer32,
      prtAcmSltIdx         INTEGER,
      prtAcmPrtIdx         INTEGER,
      prtAcmConnect        INTEGER,
      prtAcmActiveState    INTEGER,
      prtAcmAlrString      DisplayString
      }

prtAcmCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg. The write operation is valid only
       to the TmpCnfg."
      ::= { prtAcmCnfgEntry 1}

prtAcmSltIdx OBJECT-TYPE
      SYNTAX  INTEGER
     {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16),
	   notApplicable (255)
     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the module is inserted."
      ::= { prtAcmCnfgEntry 2}

prtAcmPrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
       {
       exPrt1    (1),
       exPrt2    (2),
       exPrt3    (3),
       exPrt4    (4),
       exPrt5    (5),
       exPrt6    (6),
       exPrt7    (7),
       exPrt8    (8) ,
       exPrt9    (9) ,
       exPrt10  (10) ,
       exPrt11  (11) ,
       exPrt12  (12)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  port number."
      ::= { prtAcmCnfgEntry 3}

prtAcmConnect OBJECT-TYPE
      SYNTAX  INTEGER
              {
                no  (2),
                yes (3)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the port should be
       connected or not. Only a connected port can perform activity."
      ::= {prtAcmCnfgEntry 4}

prtAcmActiveState OBJECT-TYPE
      SYNTAX  INTEGER
              {
                low  (2),
                high (3)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Electric Active State of the port."
      ::= {prtAcmCnfgEntry 5}

prtAcmAlrString OBJECT-TYPE
        SYNTAX DisplayString (SIZE(0..35))
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
        "Alarm string selected by user for the Inbound ports.
         This object is applicable only for the Inbound Ports: ext-5..ext-12.
         For the Outbound Ports (ext-1..ext-4), the size of this string will be 0."
      ::= {prtAcmCnfgEntry 6}

--prtE2CnfgTable defines the parameters of the
--E2 card ports 

prtE2CnfgTable  OBJECT-TYPE
     SYNTAX SEQUENCE OF PrtE2CnfgEntry
     MAX-ACCESS not-accessible
     STATUS  current
     DESCRIPTION
      "This is a table for E2 port parameters."
     ::= {prtE2Cnfg 1}

prtE2CnfgEntry OBJECT-TYPE
      SYNTAX PrtE2CnfgEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtE2CnfgIdx, prtE2SltIdx, prtE2PrtIdx }
      ::= { prtE2CnfgTable 1}

PrtE2CnfgEntry ::=
      SEQUENCE {
      prtE2CnfgIdx        Integer32,
      prtE2SltIdx         INTEGER,
      prtE2PrtIdx         INTEGER,
      prtE2Connect        INTEGER,
      prtE2MngOnNationalBit INTEGER
      }

prtE2CnfgIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg (1..100) being
       accessed.
       Idx 255 relates to the TmpCnfg. The write operation is valid only
       to the TmpCnfg."
      ::= { prtE2CnfgEntry 1}

prtE2SltIdx OBJECT-TYPE
      SYNTAX  INTEGER
     {
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
     }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  slot  position where
       the module is inserted."
      ::= { prtE2CnfgEntry 2}

prtE2PrtIdx OBJECT-TYPE
      SYNTAX  INTEGER
       {
       exPrt1    (1),
       exPrt2    (2)
       }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This attribute indicates a unique  port number."
      ::= { prtE2CnfgEntry 3}

prtE2Connect OBJECT-TYPE
      SYNTAX  INTEGER
              {
                no  (2),
                yes (3)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether the port should be
       connected or not. Only a connected port can perform activity."
      ::= {prtE2CnfgEntry 4}

prtE2MngOnNationalBit OBJECT-TYPE
      SYNTAX  INTEGER
              {
                no  (2),
                yes (3)
              }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates whether National Bit will be used for
       Management or not."
      ::= {prtE2CnfgEntry 5}

--prtLanWanCnfgTable defines the parameters of the Lan-Wan ports
--(for HS-ETUB MP card)

prtLanWanCnfgTable  OBJECT-TYPE
    SYNTAX SEQUENCE OF PrtLanWanCnfgEntry
    MAX-ACCESS not-accessible
    STATUS  current
    DESCRIPTION
     "This is a table for Lan-Wan port parameters."
    ::= {prtLanWanCnfg 1}

prtLanWanCnfgEntry OBJECT-TYPE
    SYNTAX PrtLanWanCnfgEntry
    MAX-ACCESS not-accessible
    STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtLanWanCnfgIdx, prtLanWanSltIdx, prtLanWanPrtIdx }
      ::= { prtLanWanCnfgTable 1}

PrtLanWanCnfgEntry ::=
    SEQUENCE {
    prtLanWanCnfgIdx        Integer32,
    prtLanWanSltIdx         INTEGER,
    prtLanWanPrtIdx         Integer32,
    prtLanWanMode           INTEGER,
    prtLanWanDestIf         Integer32,
	prtLanWanEgressVlanMode INTEGER,
	prtLanWanL2Protocol     INTEGER,
	prtLanWanStpPriority    Integer32,
	prtLanWanStpCost        Integer32,
	prtLanWanToLanVlanMode  INTEGER,
	prtLanWanVlanId         Integer32,
	prtLanWanVlanPriority   Integer32,
	prtLanWanMtu            Integer32,
	prtLanWanVlanType		INTEGER
    }

prtLanWanCnfgIdx OBJECT-TYPE
    SYNTAX  Integer32 (1..255)
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
    "This object indicates the Idx of the Cnfg (1..100) being
     accessed.
     Idx 255 relates to the TmpCnfg. The write operation is valid only
     to the TmpCnfg."
    ::= {prtLanWanCnfgEntry 1}

prtLanWanSltIdx OBJECT-TYPE
    SYNTAX  INTEGER
    {
       notApplicable (1),
       io1   (5),
       io2   (6),
       io3   (7),
       io4   (8),
       io5   (9),
       io6  (10),
       io7  (11),
       io8  (12),
       io9  (13),
       io10 (14),
       io11 (15),
       io12 (16)
    }
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
    "This object indicates a unique slot position where the module is inserted."
    ::= {prtLanWanCnfgEntry 2}

prtLanWanPrtIdx OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
    "This object indicates a unique number to identify a port
     in a specific card.
     Generally, for MP-210X/2200, the Port Index will be according to the 
     external/internal port number:  
     - exPrtX : X
     - inPrtX : 100 + X
     For FCD-155, refer to device specification" 
    ::= {prtLanWanCnfgEntry 3}

prtLanWanMode OBJECT-TYPE
    SYNTAX  INTEGER
    {
     notApplicable (1),
     bridge        (2),
     bridgeAndStp  (3),
     layer3SubnetSwitch(4)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "This object determines the working mode of this port.
    For FCD155, layer3SubnetSwitch is not applicable"
    ::= {prtLanWanCnfgEntry 4}

prtLanWanDestIf OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "This object determines the Destination Interface for the frames
     received by this port.
	 - Switching Table = 100 (it means that the destination interface
	                          will be determined by the Switching Table)
     - inPrtX (internal-X port): 100 + X .
     For FCD-155 this object is not applicable =0 " 
    ::= {prtLanWanCnfgEntry 5}

prtLanWanEgressVlanMode OBJECT-TYPE
    SYNTAX  INTEGER
    {
     notApplicable (1),
     unmodified	   (2),
	 tag           (3),
	 doubleTag 	   (4),
	 untag         (5)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "This object determines what to do with the VLAN frames that exit
     via the WAN side of the port.
     This object is not applicable when prtLanWanMode=l3SubnetSwitch(4)."
    ::= {prtLanWanCnfgEntry 6}

prtLanWanL2Protocol OBJECT-TYPE
    SYNTAX  INTEGER
    {
     notApplicable (1),
     none   	   (2),
	 ppp           (3),
	 hdlc          (4),
	 pppoHdlc      (5),
	 mlppp         (6)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "L2 Protocol.
     When prtLanWanMode=l3SubnetSwitch(4), the only valid value is ppp(3)."
    ::= {prtLanWanCnfgEntry 7}

prtLanWanStpPriority OBJECT-TYPE
    SYNTAX  Integer32 (0..255)
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "The value of the priority field which is contained in the first 
     (in network byte order) octet of the (2 octet long) Port ID."
    ::= {prtLanWanCnfgEntry 8}

prtLanWanStpCost OBJECT-TYPE
    SYNTAX  Integer32 (1..65535)
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "The contribution of this port to the path cost of paths towards 
     the spanning tree root which include this port.  802.1D-1990 recommends 
     that the default value of this parameter be in inverse	proportion 
     to the speed of the attached LAN."
    ::= {prtLanWanCnfgEntry 9}

prtLanWanToLanVlanMode OBJECT-TYPE
    SYNTAX  INTEGER
    {
     notApplicable (1),
     unmodified	   (2),
	 tag           (3),
	 doubleTag 	   (4),
	 untag         (5)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "This object determines what to do with the VLAN frames that come from
     WAN side of the port and exit towards one of the LAN ports.
     This object is applicable only when prtLanWanDestIf=100 or 101 
     (Switching Table or inPrt1)."
    ::= {prtLanWanCnfgEntry 10}

prtLanWanVlanId OBJECT-TYPE
    SYNTAX  Integer32 (0..4095)
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "This is the VLAN Id attached to a frame, when the relevant
     Vlan Mode (prtLanWanEgressVlanMode or prtLanWanToLanVlanMode) is
     tag or doubleTag.
     0=not applicable."
    ::= {prtLanWanCnfgEntry 11}

prtLanWanVlanPriority OBJECT-TYPE
    SYNTAX  Integer32 
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "This is the VLAN Priority attached to a frame, when the relevant
     Vlan Mode (prtLanWanEgressVlanMode or prtLanWanToLanVlanMode) is
     tag or doubleTag.
     Valid values: 0..7
     255=not applicable."
    ::= {prtLanWanCnfgEntry 12}

prtLanWanMtu OBJECT-TYPE
    SYNTAX  Integer32 
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "The size of the largest packet which can be sent/received on the interface, 
     specified in octets.
     Valid values change per device.
     0=not applicable."
    ::= {prtLanWanCnfgEntry 13}

prtLanWanVlanType	OBJECT-TYPE	   
      SYNTAX    INTEGER 
      {
       notApplicable          (1),
       portBasedVlan          (2),
       ieee802dot1q           (3),
	   ieee802dot1qTaggedOnly (4)
       }
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
      "This oject indicates type of VLAN this port is assigned to.
       Port Base Vlan parameters are defined by objects under
       radBridgePortBaseVlan"
       ::= { prtLanWanCnfgEntry 14}
 
--
-- The following table includes the IP addresses of all the NMS to which
-- Traps will be sent
--

--mngTrapIpTable  OBJECT-TYPE
--      SYNTAX  SEQUENCE OF MngTrapIpEntry
--      MAX-ACCESS  not-accessible
--      STATUS current
--      DESCRIPTION
--        "This table indicates  the destination address of the traps.
--         Internally it will be limited to ten addresses. "
--      ::= { agnt 7 }
--
--mngTrapIpEntry OBJECT-TYPE
--      SYNTAX  MngTrapIpEntry
--      MAX-ACCESS  not-accessible
--      STATUS  current
--      INDEX   { mngTrapIpIdx }
--      ::= { mngTrapIpTable 1 }
--
--MngTrapIpEntry  ::=
--      SEQUENCE {
--      mngTrapIpIdx   Integer32,
--      mngTrapIpIP    IpAddress,
--      mngTrapIpIPMask IpAddress
--      }
--
--mngTrapIpIdx OBJECT-TYPE
--      SYNTAX  Integer32
--      MAX-ACCESS  read-only
--      STATUS current
--      DESCRIPTION
--      " This value indicates an index of a specific IP address"
--      ::= { mngTrapIpEntry 1 }
--
--mngTrapIpIP OBJECT-TYPE
--      SYNTAX  IpAddress
--      MAX-ACCESS  read-write
--      STATUS current
--      DESCRIPTION
--      "This value indicates  the  destination addresses of the traps. "
--      ::= { mngTrapIpEntry 2 }
--
--mngTrapIpIPMask OBJECT-TYPE
--      SYNTAX  IpAddress
--      MAX-ACCESS  read-write
--      STATUS current
--      DESCRIPTION
--      "This value indicates  the  mask of the destination addresses of the traps. "
--      ::= { mngTrapIpEntry 3 }
--
--
-- Traps

--NOTIFICATIONS

 muxHubEvents OBJECT-IDENTITY
     STATUS  current
     DESCRIPTION
     "The events for ."
     ::= { muxHub 0 }

 alarmsTrap  NOTIFICATION-TYPE
     OBJECTS       { alrBufDescription }
     STATUS current
     DESCRIPTION
     "This trap is sent whenever alarm occurs in the agent."
     ::= { muxHubEvents 1 }

  sanityTrap  NOTIFICATION-TYPE
     OBJECTS       { agnSSanityCheckStatus, agnCSaveCnfgIdxCmd }
     STATUS current
     DESCRIPTION
     "This trap is sent after a data base update.
      It returns the sanity result status and the configuration no.
      checked.
      If the result is of Flip DB Sanity Check, the configuration
      no. sent will be 0.
      If the result is of Variant Sanity Check, the configuration
      no. sent will be 100."
     ::= { muxHubEvents 2 }

  cnfgFlipTrap  NOTIFICATION-TYPE
     OBJECTS       { agnSActiveCnfg }
     STATUS current
     DESCRIPTION
     "This trap is sent upon change of the active Configuration DB.
      Attached, is the new active Configuration no."
     ::= { muxHubEvents 3 }

  flipDbChangeTrap  NOTIFICATION-TYPE
     STATUS current
     DESCRIPTION
     "This trap is sent upon change of the active Flip tables
      (Flip DB)."
     ::= { muxHubEvents 4 }

  statusChangedTrap  NOTIFICATION-TYPE
     OBJECTS       { agnLed }
     STATUS current
     DESCRIPTION
     "This trap is sent upon any change of the LEDs status."
     ::= { muxHubEvents 5 }