-- file :a2002nv3.pkb
-- 
ACE2002-MIB

			DEFINITIONS ::= BEGIN

--Title:     ACE2002   MIB

-- Copyright 2201 RAD Data Communications, Ltd.
-- All Rights Reserved.  

-- It is RAD's intent to encourage the widespread use of
-- this Specification in connection with the management of
-- RAD products. RAD grants vendors, end-users,
-- and other interested parties a non-exclusive license to
-- use this Specification in connection with the management
-- of RAD products.

-- This Specification is supplied "as is," and RAD makes
-- no warranty, either express or implied, as to the use,
-- operation, condition, or performance of the Specification.

IMPORTS
      TimeTicks,enterprises, 
      IpAddress, OBJECT-TYPE, Integer32, 
      Counter32, Gauge32, OBJECT-IDENTITY,
      NOTIFICATION-TYPE, Counter64,Unsigned32 FROM SNMPv2-SMI
	  PerfCurrentCount, 
	  PerfIntervalCount, PerfTotalCount     FROM PerfHist-TC-MIB
      InterfaceIndex, ifAlias, ifIndex		FROM IF-MIB				
      dsx1LineStatus, 
      dsx1LineStatusLastChange,
      dsx1CurrentIndex, dsx1LineIndex,
      dsx1IntervalIndex, dsx1IntervalNumber, 
      dsx1LoopbackStatus, 
      dsx1TotalIndex                        FROM DS1-MIB 
      imaGroupIndex, imaLinkIfIndex, 
      imaGroupFailureStatus  		        FROM IMA-MIB
      RowStatus, DisplayString, TimeStamp,
      DateAndTime, TruthValue               FROM SNMPv2-TC
	  SnmpAdminString 		                FROM SNMP-FRAMEWORK-MIB
	  frAtmIwfConnectionEntry               FROM FR-ATM-PVC-SERVICE-IWF-MIB
	  isdnSignalingEntry                    FROM ISDN-MIB
	  VlanIndex, PortList                   FROM Q-BRIDGE-MIB
      dot1dBasePortEntry					FROM BRIDGE-MIB
	  atmfCESConfEntry                      FROM ATMF-CES
	  atmVclEntry, aal5VccEntry,
	  aal5VccVpi, aal5VccVci,    
	  atmVplVpi, atmVclVpi, atmVclVci,       
	  	  atmVpCrossConnectEntry,
	  atmVcCrossConnectEntry,               
	        atmVclEntry, aal5VccEntry       FROM ATM-MIB
	  IANAifType							FROM IANAifType-MIB	
	  ipoaLisIfMappingEntry					FROM IPOA-MIB ;


-- Some MIB compilers need those two lines:
-- enterprises OBJECT IDENTIFIER ::=
--		     { iso org(3) dod(6) internet(1) private(4) 1 }

 MacAddress ::= OCTET STRING (SIZE(6))

rad OBJECT IDENTIFIER ::= { enterprises 164 }
radTokenRing OBJECT IDENTIFIER ::= { rad 1 } -- RAD Token Ring tree
radFddi      OBJECT IDENTIFIER ::= { rad 2 } -- rad FDDI Tree
radWan       OBJECT IDENTIFIER ::= { rad 3 } -- rad WAN Tree
radBridges  OBJECT IDENTIFIER ::= {rad 4 }
radConverters OBJECT IDENTIFIER ::= { rad 5 }  -- RAD Converters products' tree
radGen        OBJECT IDENTIFIER ::= { rad 6} -- General information
radStkHub         OBJECT IDENTIFIER ::=  { rad 7 } -- stackable products
radAtm        OBJECT IDENTIFIER ::=  { rad 12} -- stackable products
wanGen  OBJECT IDENTIFIER  ::=  {radWan 1}
diverseIfWanGen  OBJECT IDENTIFIER  ::=  {wanGen 6}

--atmNte	 OBJECT IDENTIFIER ::= { radAtm 3 }
--atmNtePrt		OBJECT IDENTIFIER ::= { atmNte 2 }
--atmNtePrtConfig		OBJECT IDENTIFIER ::= { atmNtePrt 1 }
--dacsMux       OBJECT IDENTIFIER ::= {radWan 3}
--genDacsMux    OBJECT IDENTIFIER ::= {dacsMux 4}
radRouter     OBJECT IDENTIFIER ::= { rad 11 }  
rtrBridge     OBJECT IDENTIFIER ::= { radRouter 7 }
radExperimental OBJECT IDENTIFIER ::= { rad 20 }  -- Drafts that have no MIB tree yet
-- igmpStdMIB MODULE-IDENTITY ::= { radExperimental 1 }
-- apsMIB  OBJECT IDENTIFIER  ::= { radExperimental 2 }


-- 
-- file :v:\doc\rdv\mib\ver495\radgen.txt
-- 
--Version:   5.00
--First Version Date:   25.01.99              
--By:        Orly Nicklass
--File:      radgen.txt

--Last update: 09-Oct-2003 by Smadar Tauber


systems OBJECT IDENTIFIER ::= { radGen 1}  --    list of RAD products

--agnt OBJECT IDENTIFIER ::= { radGen 2}  agent general tree
 
--services OBJECT IDENTIFIER ::= { radGen 3}  See services.txt


radSysTR  OBJECT IDENTIFIER ::= { systems 1 } -- RAD Token Ring 

radRADring    OBJECT IDENTIFIER  ::= { radSysTR  1 }

radTMA  OBJECT IDENTIFIER  ::= { radSysTR  2 }

radRingMonitor    OBJECT IDENTIFIER  ::= { radSysTR  3 }

radSysFddi OBJECT IDENTIFIER ::= { systems 2 } -- RAD Fddi 

radFDX100  OBJECT IDENTIFIER ::= { radSysFddi  1 } -- RAD Fddi
 
radSysWan OBJECT IDENTIFIER ::= { systems 3 }  -- RAD Wan products

radSysWanEvents OBJECT-IDENTITY
     STATUS  current
     DESCRIPTION
     "The events for RAD Wan products."
     ::= { radSysWan 0 }

radMP2100      OBJECT IDENTIFIER ::= { radSysWan  1 }
radMP2104      OBJECT IDENTIFIER ::= { radSysWan  2 }
radMP2100B     OBJECT IDENTIFIER ::= { radSysWan  3 }
radMP2100F     OBJECT IDENTIFIER ::= { radSysWan  4 }

radMP2100H      OBJECT IDENTIFIER ::= { radSysWan  5 }
radMP2104H      OBJECT IDENTIFIER ::= { radSysWan  6 }
radMP2200B      OBJECT IDENTIFIER ::= { radSysWan  7 }
radMP2200F      OBJECT IDENTIFIER ::= { radSysWan  8 }

radMX3000       OBJECT IDENTIFIER ::= { radSysWan  9 }
radMX3004       OBJECT IDENTIFIER ::= { radSysWan 10 }
radMX30			OBJECT IDENTIFIER ::= { radSysWan 11 }
radMX300		OBJECT IDENTIFIER ::= { radSysWan 12 }

radVOIP         OBJECT IDENTIFIER ::= { radSysWan 13 }

radKM2100	    OBJECT IDENTIFIER ::= { radSysWan 15 }
radKM2104		OBJECT IDENTIFIER ::= { radSysWan 16 }

radDXC30        OBJECT IDENTIFIER ::= { radSysWan 20 }
radDXC10A       OBJECT IDENTIFIER ::= { radSysWan 21 }
radDXC8R        OBJECT IDENTIFIER ::= { radSysWan 22 }
radDXC30E       OBJECT IDENTIFIER ::= { radSysWan 23 }
radDXC3000      OBJECT IDENTIFIER ::= { radSysWan 24 }
radDXC8RNew     OBJECT IDENTIFIER ::= { radSysWan 25 }

radFcdT1L        OBJECT IDENTIFIER ::= { radSysWan 28 }
radFcdE1L        OBJECT IDENTIFIER ::= { radSysWan 29 }
radFcdT1         OBJECT IDENTIFIER ::= { radSysWan 30 }
radFcdE1         OBJECT IDENTIFIER ::= { radSysWan 31 }
radFcdE1I        OBJECT IDENTIFIER ::= { radSysWan 32 }
radFcdT1M        OBJECT IDENTIFIER ::= { radSysWan 33 }
radFcdE1M        OBJECT IDENTIFIER ::= { radSysWan 34 }
radFcdIP         OBJECT IDENTIFIER ::= { radSysWan 35} 
radFcdT1A        OBJECT IDENTIFIER ::= { radSysWan 36 }
radFcdE1A        OBJECT IDENTIFIER ::= { radSysWan 37 }
radFcdW          OBJECT IDENTIFIER ::= { radSysWan 38 }
radFcdSTM        OBJECT IDENTIFIER ::= { radSysWan 39 }

radHtuE1Sa      OBJECT IDENTIFIER ::= { radSysWan 40 }
radHtuE1        OBJECT IDENTIFIER ::= { radSysWan 41 }	 --card
radHtu2Sa       OBJECT IDENTIFIER ::= { radSysWan 42 }
radHtu2         OBJECT IDENTIFIER ::= { radSysWan 43 }	 --card
radAsmi450R768Sa OBJECT IDENTIFIER ::= { radSysWan 44 }
radAsmi450R768  OBJECT IDENTIFIER ::= { radSysWan 45 }	 --card
radAsmi450R1152Sa  OBJECT IDENTIFIER ::= { radSysWan 46 }
radAsmi450R1152 OBJECT IDENTIFIER ::= { radSysWan 47 }	 --card

radLrs12F        OBJECT IDENTIFIER ::= { radSysWan 48 }
radLrs12B        OBJECT IDENTIFIER ::= { radSysWan 49 }
radLrs52         OBJECT IDENTIFIER ::= { radSysWan 50 }

radHcdE1Sa       OBJECT IDENTIFIER ::= { radSysWan 51 }
radHcdE1         OBJECT IDENTIFIER ::= { radSysWan 52 }  --card
radHtuT1Sa       OBJECT IDENTIFIER ::= { radSysWan 53 }
radHtuT1         OBJECT IDENTIFIER ::= { radSysWan 54 }	 --card

radOptimux4E1         OBJECT IDENTIFIER ::= { radSysWan 55 }
radOptimux4T1         OBJECT IDENTIFIER ::= { radSysWan 56 }
radOptimuxXLE1         OBJECT IDENTIFIER ::= { radSysWan 57 }
radOptimuxXLT1         OBJECT IDENTIFIER ::= { radSysWan 58 }
radOptimuxXL16E1       OBJECT IDENTIFIER ::= { radSysWan 59 }

radImx64        OBJECT IDENTIFIER ::= { radSysWan 60 }
radImx6L        OBJECT IDENTIFIER ::= { radSysWan 61 }
radImx2         OBJECT IDENTIFIER ::= { radSysWan 62 }
radImx4T1       OBJECT IDENTIFIER ::= { radSysWan 63 }
radImx4E1       OBJECT IDENTIFIER ::= { radSysWan 64 }
radImx2T1E1     OBJECT IDENTIFIER ::= { radSysWan 65 }
radImxi4		OBJECT IDENTIFIER ::= { radSysWan 66 }

radOptimux155     OBJECT IDENTIFIER ::= { radSysWan 67 }  --SA
radOptimux4T1L    OBJECT IDENTIFIER ::= { radSysWan 68 }  --SA Low Cost
radOptimux4E1L    OBJECT IDENTIFIER ::= { radSysWan 69 }  --SA Low Cost
radHtuE1SaV2      OBJECT IDENTIFIER ::= { radSysWan 70 }
radHtuE1V2        OBJECT IDENTIFIER ::= { radSysWan 71 }  --card
radFomiE3         OBJECT IDENTIFIER ::= { radSysWan 72 }  --card
radFomiT3         OBJECT IDENTIFIER ::= { radSysWan 73 }  --card
radOpt4E1C        OBJECT IDENTIFIER ::= { radSysWan 74 }  --card
radOpt4T1C        OBJECT IDENTIFIER ::= { radSysWan 75 }  --card
radPrbiE3         OBJECT IDENTIFIER ::= { radSysWan 76 }  --SA
radPrbiT3         OBJECT IDENTIFIER ::= { radSysWan 77 }  --SA
radHcd4Sa         OBJECT IDENTIFIER ::= { radSysWan 78 }  --SA
radOptimuxT3      OBJECT IDENTIFIER ::= { radSysWan 79 }  --SA

radFRmon          OBJECT IDENTIFIER ::= { radSysWan 80 } 
radIpMux4         OBJECT IDENTIFIER ::= { radSysWan 81 } 
radIpMux1         OBJECT IDENTIFIER ::= { radSysWan 82 } 
radIpMux16        OBJECT IDENTIFIER ::= { radSysWan 83 } 
radIpMux1E        OBJECT IDENTIFIER ::= { radSysWan 84 }
radVmux2100       OBJECT IDENTIFIER ::= { radSysWan 85 }
radMP104          OBJECT IDENTIFIER ::= { radSysWan 86 }
radMP204          OBJECT IDENTIFIER ::= { radSysWan 87 }
radVmux110        OBJECT IDENTIFIER ::= { radSysWan 88 }
-- reserved for radVmux105        OBJECT IDENTIFIER ::= { radSysWan 89 }

radFcd155        OBJECT IDENTIFIER ::= { radSysWan 90 } --SA
radIpMux8        OBJECT IDENTIFIER ::= { radSysWan 91 }
radOptimux155DS3 OBJECT IDENTIFIER ::= { radSysWan 92 }  --SA
radOptimuxT3L    OBJECT IDENTIFIER ::= { radSysWan 93 }  --SA Low Cost
-- reserved for radIpMux1000     OBJECT IDENTIFIER ::= { radSysWan 94 }
radOp16E1L		 OBJECT IDENTIFIER ::= { radSysWan 95 }  --19 inch box
radOp16E1LS      OBJECT IDENTIFIER ::= { radSysWan 96 }  --half 19 inch box (single)
radPRBm20        OBJECT IDENTIFIER ::= { radSysWan 97 }  -- half 19 inch box
radPRBm22        OBJECT IDENTIFIER ::= { radSysWan 98 }  -- 19 inch box
-- reserved for radAsmi52Sa      OBJECT IDENTIFIER ::= { radSysWan 99 }

radOpXLE1        OBJECT IDENTIFIER ::= { radSysWan 100 } -- New-Look
radOpXLT1        OBJECT IDENTIFIER ::= { radSysWan 101 } -- New-Look
radOpXL16E1      OBJECT IDENTIFIER ::= { radSysWan 102 } -- New-Look


radSysBRG OBJECT IDENTIFIER ::= { systems 4 }  -- RAD Bridges products

radTRE1  OBJECT IDENTIFIER ::= { radSysBRG 1 }  -- RAD Bridges products

radTRE1D  OBJECT IDENTIFIER ::= { radSysBRG 2 }  -- RAD Bridges products

radTRE8  OBJECT IDENTIFIER ::= { radSysBRG 3 }  -- RAD Bridges products

radTRE8D  OBJECT IDENTIFIER ::= { radSysBRG 4 }  -- RAD Bridges products

radMBE1  OBJECT IDENTIFIER ::= { radSysBRG 5 }  -- RAD Bridges products

radMBE1D  OBJECT IDENTIFIER ::= { radSysBRG  6 }  -- RAD Bridges products

radMBE8  OBJECT IDENTIFIER ::= { radSysBRG  7 }  -- RAD Bridges products

radMBE8D  OBJECT IDENTIFIER ::= { radSysBRG  8 }  -- RAD Bridges products

radMLBT   OBJECT IDENTIFIER ::= { radSysBRG  9 }  -- RAD Bridges products 

radFEB4DAS    OBJECT IDENTIFIER ::= { radSysBRG  10 }  -- RAD Bridges products

radTrimBrg10  OBJECT IDENTIFIER ::= { radSysBRG 11 }  -- RAD Bridges products

radTrimBrg16  OBJECT IDENTIFIER ::= { radSysBRG 12 }  -- RAD Bridges products

radRRTRE8  OBJECT IDENTIFIER ::= { radSysBRG 13 }  -- RAD Bridges products

radRRTRE8D  OBJECT IDENTIFIER ::= { radSysBRG 14 }  -- RAD Bridges products

radRRMLBT   OBJECT IDENTIFIER ::= { radSysBRG 15 }  -- RAD Bridges products 

radRRMLBTF   OBJECT IDENTIFIER ::= { radSysBRG 16 }  -- RAD Bridges products 

radRRTRE1D  OBJECT IDENTIFIER ::= { radSysBRG 17 }  -- RAD Bridges products

radTRERAS  OBJECT IDENTIFIER ::= { radSysBRG 18 }  -- RAD Bridges products

radTRERASa  OBJECT IDENTIFIER ::= { radSysBRG 19 }  -- RAD Bridges products

radMBERAS  OBJECT IDENTIFIER ::= { radSysBRG 20 }  -- RAD Bridges products

radMBERASa  OBJECT IDENTIFIER ::= { radSysBRG 21 }  -- RAD Bridges products
 
radFEB4FDX   OBJECT IDENTIFIER ::= { radSysBRG 22 }  -- RAD Bridges products

radFEB4SAS  OBJECT IDENTIFIER ::= { radSysBRG 23 }  -- RAD Bridges products

radRRFTBDAS  OBJECT IDENTIFIER ::= { radSysBRG 24 }  -- RAD Bridges products

radRRFTBSAS  OBJECT IDENTIFIER ::= { radSysBRG 25 }  -- RAD Bridges products

radFTBDAS    OBJECT IDENTIFIER ::= { radSysBRG 26 }  -- RAD Bridges products

radFTBSAS    OBJECT IDENTIFIER ::= { radSysBRG 27 }  -- RAD Bridges products

radFastWay100    OBJECT IDENTIFIER ::= { radSysBRG 28 }  -- RAD Bridges products

radSysCnvrtr OBJECT IDENTIFIER ::= { systems 5 }  -- RAD Converters products

radSTC1   OBJECT IDENTIFIER ::= { radSysCnvrtr 1 }  -- RAD Converters products

radSTC2   OBJECT IDENTIFIER ::= { radSysCnvrtr 3 }  -- RAD Converters products

radSTC1UDP  OBJECT IDENTIFIER ::= { radSysCnvrtr 4 }  -- RAD Converters products

radSTC2UDP  OBJECT IDENTIFIER ::= { radSysCnvrtr 6 }  -- RAD Converters products

radFTC1   OBJECT IDENTIFIER ::= { radSysCnvrtr 10 }  -- RAD Converters products

radFTC2   OBJECT IDENTIFIER ::= { radSysCnvrtr 12 }  -- RAD Converters products

radFTC1UDP    OBJECT IDENTIFIER ::= { radSysCnvrtr 13 }  -- RAD Converters products

radFTC2UDP    OBJECT IDENTIFIER ::= { radSysCnvrtr 15 }  -- RAD Converters products

radSEC1   OBJECT IDENTIFIER ::= { radSysCnvrtr 20 }  -- RAD Converters products

radSEC2   OBJECT IDENTIFIER ::= { radSysCnvrtr 22 }  -- RAD Converters products

radSEC1UDP   OBJECT IDENTIFIER ::= { radSysCnvrtr 23 }  -- RAD Converters products

radSEC2UDP   OBJECT IDENTIFIER ::= { radSysCnvrtr 25 }  -- RAD Converters products

radFEC1   OBJECT IDENTIFIER ::= { radSysCnvrtr 30 }  -- RAD Converters products

radFEC2   OBJECT IDENTIFIER ::= { radSysCnvrtr 32 }  -- RAD Converters products

radFEC1UDP   OBJECT IDENTIFIER ::= { radSysCnvrtr 33 }  -- RAD Converters products

radFEC2UDP   OBJECT IDENTIFIER ::= { radSysCnvrtr 35 }  -- RAD Converters products

radRIC155   OBJECT IDENTIFIER ::= { radSysCnvrtr 36 }  -- RAD Converters products


radSysStkHub  OBJECT IDENTIFIER ::= { systems 7 }  -- RAD Stackable products

radRBHE    OBJECT IDENTIFIER ::= { radSysStkHub 1 }  -- RAD Stackable products

radRBHT    OBJECT IDENTIFIER ::= { radSysStkHub 2 }  -- RAD Stackable products

radRBHEEvents OBJECT-IDENTITY
     STATUS  current
     DESCRIPTION
     "The events for RAD Stackable products."
     ::= { radRBHE 0 }

radRBHTEvents OBJECT-IDENTITY
     STATUS  current
     DESCRIPTION
     "The events for RAD Stackable products."
     ::= { radRBHT 0 }

radETS4fddiDAS   OBJECT IDENTIFIER ::= { radSysStkHub 3 }  -- RAD Stackable products

radETS4fddiSAS   OBJECT IDENTIFIER ::= { radSysStkHub 4 }  -- RAD Stackable products

radSAHEMX  OBJECT IDENTIFIER ::= { radSysStkHub 5 }  -- RAD Stackable products

radSAHTM   OBJECT IDENTIFIER ::= { radSysStkHub 6 }  -- RAD Stackable products

radETS4   OBJECT IDENTIFIER ::= { radSysStkHub 7 }  -- RAD Stackable products

radSAHEMU  OBJECT IDENTIFIER ::= { radSysStkHub 8 }  -- RAD Stackable products


unknown    	OBJECT IDENTIFIER ::= { radSysStkHub 9 }  -- RAD Stackable products

radSAH16Eint   OBJECT IDENTIFIER ::= { radSysStkHub 10 }  -- RAD Stackable products

radSAH16Tint   OBJECT IDENTIFIER ::= { radSysStkHub 11 }  -- RAD Stackable products

radSAH16Eext   OBJECT IDENTIFIER ::= { radSysStkHub 12 }  -- RAD Stackable products

radSAH16Text   OBJECT IDENTIFIER ::= { radSysStkHub 13 }  -- RAD Stackable products



radSysPS OBJECT IDENTIFIER ::=  { systems 8 } -- RAD Packet Switch  (PS) products 

radSysPSEvents OBJECT-IDENTITY
     STATUS  current
     DESCRIPTION
     "The events for RAD Packet Switch  (PS) products."
     ::= { radSysPS 0 }

radSPS2  OBJECT IDENTIFIER ::=  { radSysPS 1 } -- RAD Packet Switch  (PS) products 

radSPS3  OBJECT IDENTIFIER ::=  { radSysPS 2 } -- RAD Packet Switch  (PS) products 

radSPS6  OBJECT IDENTIFIER ::=  { radSysPS 3 } -- RAD Packet Switch  (PS) products 

radSPS9  OBJECT IDENTIFIER ::=  { radSysPS 4 } -- RAD Packet Switch  (PS) products 

radSPS12 OBJECT IDENTIFIER ::=  { radSysPS 5 } -- RAD Packet Switch  (PS) products 

radAPD2  OBJECT IDENTIFIER ::=  { radSysPS 6 } -- RAD Packet Switch  (PS) products 

radAPD8  OBJECT IDENTIFIER ::=  { radSysPS 7 } -- RAD Packet Switch  (PS) products 

radAPS8  OBJECT IDENTIFIER ::=  { radSysPS 8 } -- RAD Packet Switch  (PS) products 

radAPS16 OBJECT IDENTIFIER ::=  { radSysPS 9 } -- RAD Packet Switch  (PS) products 

radAPS24 OBJECT IDENTIFIER ::=  { radSysPS 10 } -- RAD Packet Switch  (PS) products 

radSPS3S  OBJECT IDENTIFIER ::=  { radSysPS 11} -- RAD Packet Switch  (PS) products 

radFPS8  OBJECT IDENTIFIER ::=  { radSysPS 12} -- RAD Packet Switch  (PS) products 

radFPS12  OBJECT IDENTIFIER ::=  { radSysPS 13} -- RAD Packet Switch  (PS) products 

radSPS3ScSL  OBJECT IDENTIFIER ::= { radSysPS 14} -- RAD Packet Switch  (PS) products 

radSPS3Sc2S  OBJECT IDENTIFIER ::=  { radSysPS 15} -- RAD Packet Switch  (PS) products 

radFPS8c OBJECT IDENTIFIER ::=  { radSysPS 16} -- RAD Packet Switch  (PS) products

radFPS4 OBJECT IDENTIFIER ::=  { radSysPS 17} -- RAD Packet Switch  (PS) products



radSysEth  OBJECT IDENTIFIER ::= { systems 9 } -- RAD Ethernet products 

radEP8T    OBJECT IDENTIFIER ::= {radSysEth 1} -- RAD Ethernet products

radEP4TAUI   OBJECT IDENTIFIER ::= {radSysEth 2} -- RAD Ethernet products

radEP4T2FL   OBJECT IDENTIFIER ::= {radSysEth 3} -- RAD Ethernet products

radEP4TFL    OBJECT IDENTIFIER ::= {radSysEth 4} -- RAD Ethernet products

radEP4FL     OBJECT IDENTIFIER ::= {radSysEth 5} -- RAD Ethernet products


radEPR8T   OBJECT IDENTIFIER ::= {radSysEth 7} -- RAD Ethernet products

radEPR4TAUI  OBJECT IDENTIFIER ::= {radSysEth 8} -- RAD Ethernet products

radEPR4T2FL  OBJECT IDENTIFIER ::= {radSysEth 9} -- RAD Ethernet products

radEPR4TFL   OBJECT IDENTIFIER ::= {radSysEth 10} -- RAD Ethernet products

radEPR4FL    OBJECT IDENTIFIER ::= {radSysEth 11} -- RAD Ethernet products



radSysRtr  OBJECT IDENTIFIER ::= { systems 11 } -- RAD Router products 

radSysRtrEvents OBJECT-IDENTITY
     STATUS  current
     DESCRIPTION
     "The events for RAD Router products."
     ::= { radSysRtr 0 }

radRTED    OBJECT IDENTIFIER ::= {radSysRtr 1} -- RAD Router products

radRTEM    OBJECT IDENTIFIER ::= {radSysRtr 2} -- RAD Router products

radRTEC    OBJECT IDENTIFIER ::= {radSysRtr 3} -- RAD Router products

radWebRanger    OBJECT IDENTIFIER ::= {radSysRtr 4} -- RAD Router products

radTinyRouter   OBJECT IDENTIFIER ::= {radSysRtr 5} -- RAD Router products

radLA240	    OBJECT IDENTIFIER ::= {radSysRtr 6} -- RAD Router products

radSuperLan	    OBJECT IDENTIFIER ::= {radSysRtr 7} -- RAD Router products (LA-240)

radLA240I	    OBJECT IDENTIFIER ::= {radSysRtr 8} -- RAD Router products

radFcdIsdn      OBJECT IDENTIFIER ::= {radSysRtr 9} -- RAD Router products

radEFcdIp	    OBJECT IDENTIFIER ::= {radSysRtr 10} -- RAD Router products (FCD-IP/D)

radFcdIpD       OBJECT IDENTIFIER ::= {radSysRtr 11} -- RAD Router products

radFcdIpM       OBJECT IDENTIFIER ::= {radSysRtr 12} -- RAD Router products (LA-240)


radSysAtm  OBJECT IDENTIFIER ::= { systems 12 } -- RAD ATM products 

radSysAtmEvents OBJECT-IDENTITY
     STATUS  current
     DESCRIPTION
     "The events for RAD ATM products."
     ::= { radSysAtm 0 }

radStarSwitch    OBJECT IDENTIFIER ::= {radSysAtm 1} --RAD StartSwitch products

radStarSwitchATM25    OBJECT IDENTIFIER ::= {radStarSwitch 1} --RAD StartSwitch products
radStarSwitchATM25L   OBJECT IDENTIFIER ::= {radStarSwitch 2} --RAD StartSwitch products
radStarSwitchATM155   OBJECT IDENTIFIER ::= {radStarSwitch 3} --RAD StartSwitch products


radAtmCsuDsu  OBJECT IDENTIFIER ::= {radSysAtm 2} --RAD CSU/DSU products 

radAmcdE1  OBJECT IDENTIFIER ::= {radAtmCsuDsu 1} -- RAD CSU/DSU products
radAmcdT1  OBJECT IDENTIFIER ::= {radAtmCsuDsu 2} -- RAD CSU/DSU products
radAce20E  OBJECT IDENTIFIER ::= {radAtmCsuDsu 3} -- RAD CSU/DSU products
radAce20T  OBJECT IDENTIFIER ::= {radAtmCsuDsu 4} -- RAD CSU/DSU products

radAce2005 OBJECT IDENTIFIER ::= { radAtmCsuDsu 5} -- RAD ACE2005
radAce2002 OBJECT IDENTIFIER ::= { radAtmCsuDsu 6} -- RAD ACE2002
radAce2002E OBJECT IDENTIFIER ::= { radAtmCsuDsu 7} -- RAD ACE2002E

radAce2E  OBJECT IDENTIFIER ::= {radAtmCsuDsu 8} -- RAD CSU/DSU products
radAce2T  OBJECT IDENTIFIER ::= {radAtmCsuDsu 9} -- RAD CSU/DSU products

radMlAtmE1  OBJECT IDENTIFIER ::= {radAtmCsuDsu 10} -- RAD ATM Piggy
radMlAtmT1  OBJECT IDENTIFIER ::= {radAtmCsuDsu 11} -- RAD ATM Piggy

radAmc102  OBJECT IDENTIFIER ::= {radAtmCsuDsu 12} -- RAD AMC102
radAmc102c  OBJECT IDENTIFIER ::= {radAtmCsuDsu 13} -- RAD AMC102 CARD

radAce202 OBJECT IDENTIFIER ::= { radAtmCsuDsu 14} -- RAD ACE202

radAce  OBJECT IDENTIFIER ::= {radSysAtm 3} --RAD ACE products 
radAce101  OBJECT IDENTIFIER ::= {radAce 1} -- RAD ACE101
radAce102  OBJECT IDENTIFIER ::= {radAce 2} -- RAD ACE102
radAce50   OBJECT IDENTIFIER ::= {radAce 3} -- RAD ACE50
radAce52   OBJECT IDENTIFIER ::= {radAce 4} -- RAD ACE52

radSysLA	  OBJECT IDENTIFIER ::= {systems 13} --RAD  IAD (Integrated Access Device) products
radLA140      OBJECT IDENTIFIER ::= {radSysLA 1} -- RAD LA-140
radLA110      OBJECT IDENTIFIER ::= {radSysLA 2} -- RAD LA-110
radLA104      OBJECT IDENTIFIER ::= {radSysLA 3} -- RAD LA-104 (LA-110 with IMA)

radSysTerminal  OBJECT IDENTIFIER ::= {systems 100} --RAD Terminal Meta-MIB; 
-- no objects should be added to this branch in RAD MIB.                                     


agnt OBJECT IDENTIFIER ::= { radGen 2} 
-- agent general tree
-- Agent General  
agnHwVersion OBJECT-TYPE
      SYNTAX  DisplayString
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "ASCII string for description and display of the agent hardware version,
      as it is known by the agent software.The user can update the version
       upon request when he changes   components in the agent's module  "
      ::= { agnt 1 }

agnTrapMask OBJECT-TYPE   
      SYNTAX  Integer32 
      MAX-ACCESS  read-write    
      STATUS  current
      DESCRIPTION
      "The value of this attribute determines the type of traps the 
       agent should mask and not send to the management console. The 
       value is differently determined for different products. There are 
       mainly two methods:
       - an integer number, specifying the traps' severity.
       - a sum of 2**n, where n is a bit assigned to a certain 
         masked trap group.
       User should consult the product specification, to find out 
       the method employed."
      ::= { agnt 2 }

agnTrapValue OBJECT-TYPE
	SYNTAX  OCTET STRING
	MAX-ACCESS  read-only
	STATUS deprecated
	DESCRIPTION
	"The value of the trap decoded in internal RAD format. Full description is given
	  in the Trap definition file"
	::= {agnt 3}

agnChangeCnt OBJECT-TYPE
	SYNTAX  Counter32
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
	"The number of changes in system configuration that were  reported to the 
	manager since last cold start"
	::= {agnt 4 }

agnSpecific OBJECT-TYPE
      SYNTAX  OBJECT IDENTIFIER
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      " Object identifier of entity containing additional information 
      regarding this instance."
      ::= { agnt 5}

agnConfigMsg OBJECT-TYPE   
      SYNTAX  OCTET STRING
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Full configuration message  coded in internal RAD application format.
       This entry describes agent's configuration.

       For MP-2200 R3, this object describes agent's support of the V5.1
       feature: 1 octet ; bit 0 (LSB). 
       '1' - V5.1 feature is supported
       '0' - V5.1 feature is not supported."
      ::= { agnt 6 }

-- Manager table to record all IP addresses

mngTrapIpTable  OBJECT-TYPE
	SYNTAX  SEQUENCE OF MngEntry
	MAX-ACCESS  not-accessible
	STATUS current
	DESCRIPTION
	"This table indicates  the destination address of the traps.
	  Internally it will be limited to ten addresses. "
	::= { agnt 7 }

mngEntry OBJECT-TYPE
	SYNTAX  MngEntry
	MAX-ACCESS  not-accessible
	STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {  mngID }
	::= { mngTrapIpTable 1 }


MngEntry  ::=
	    SEQUENCE {
	mngID
	  Integer32,
	mngIP
	  IpAddress,
	mngIPMask
	  IpAddress,
    mngTrapMask
      Integer32	
    }

mngID OBJECT-TYPE
	SYNTAX  Integer32 
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
	" This value indicates an index of a specific IP address"
	::= { mngEntry 1 }

mngIP OBJECT-TYPE
	SYNTAX  IpAddress 
	MAX-ACCESS  read-write
	STATUS current
	DESCRIPTION
	"This value indicates  the  destination address of the traps. IP 0.0.0.0 removes the entry. "
	::= { mngEntry 2 }

mngIPMask OBJECT-TYPE
	SYNTAX  IpAddress 
	MAX-ACCESS  read-write
	STATUS deprecated
	DESCRIPTION
	"This value indicates  the  mask of the destination addresses of the traps. "
	::= { mngEntry 3 }

mngTrapMask OBJECT-TYPE
	SYNTAX  Integer32 
	MAX-ACCESS  read-write
	STATUS current
	DESCRIPTION
      "The value of this attribute determines the type of traps the 
       agent should mask and not send to this NMS. The 
       value is differently determined for different products. There are 
       mainly two methods:
       - an integer number, specifying the traps' severity.
       - a sum of 2**n, where n is a bit assigned to a certain 
         masked trap group.
       User should consult the product specification, to find out 
       the method employed."
	::= { mngEntry 4 }

agnIndication OBJECT-TYPE   
      SYNTAX  INTEGER {
		 faulty  (1), -- =major
		 warning (2),
		 normal  (3), -- off
		 minor   (4),
		 major   (5),
		 event   (6),
		 critical(7)
		}
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Attribute describing the state of the entity the agent is responsible for.
       In case of a modular entity, the value of this attribute will be according
       to the component which is in the worst state.
       The order of severity (from top to bottom) is:
       critical-> major (or faulty)-> minor-> event-> warning-> normal (off)."   
      ::= { agnt 8 }


agnMonitorModeCmd OBJECT-TYPE
	SYNTAX  INTEGER {
	notApplicable(1),
	off(2),
	on(3)
	}
	MAX-ACCESS  read-write
	STATUS current
	DESCRIPTION
	"Setting this attribute to ON, will enforce the agent to change its mode of operation to
	 Monitor Mode"
	::= {agnt 9}

agnLed OBJECT-TYPE
	SYNTAX  OCTET STRING
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
	"This entry specifies  the LEDs status of the agent module . Each led will be represented by 4 
	 bits  where the first 2 bits (left) will specify  the status :
	 (00=NA, 01=OFF, 10=ON, 11=BLINK),
     and the next two bits (right) will specify the color :
     (00=GREEN, 01=RED, 10=YELLOW, 11=GRAY)"
	::= {agnt 10}

trapTable  OBJECT-TYPE
	SYNTAX  SEQUENCE OF TrapEntry
	MAX-ACCESS  not-accessible
	STATUS current
	DESCRIPTION
	"This table includes the last few traps generated by the agent, for future retrieval. The table
	 has a limited capacity. If traps are not retrieved in proper time, they will be
	 over-written by new traps "
	::= {agnt 11}

trapEntry OBJECT-TYPE
	SYNTAX  TrapEntry
	MAX-ACCESS  not-accessible
	STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {  trapID }
	::= { trapTable 1 }

TrapEntry  ::=
	    SEQUENCE {
	trapID
	  Integer32,
	trapVal
	  DisplayString,
	 trapTimeSinceOccurrence
	   TimeTicks
	}

trapID OBJECT-TYPE
	SYNTAX  Integer32 
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
	" This value indicates an index of a specific trap "
	::= { trapEntry 1 }

trapVal OBJECT-TYPE
	SYNTAX  DisplayString 
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
	"This value is the actual ASCII description  of the trap. "
	::= { trapEntry 2 }

trapTimeSinceOccurrence OBJECT-TYPE
	 SYNTAX    TimeTicks
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
	"This value indicates the amount of  time passed since the occurrence of the event that
	   trigger this trap. "
	::= { trapEntry 3 }

fileTransfer  OBJECT IDENTIFIER ::= { agnt 12 }

fileServerIP  OBJECT-TYPE
	SYNTAX  IpAddress
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
	"The IP address of the server from which the file is loaded "
	::= { fileTransfer 1 }

fileName  OBJECT-TYPE
	SYNTAX  DisplayString
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
	"The name of the file to be loaded. For protection, read returns
	 NULL. "
	::= { fileTransfer 2 }

fileTransCmd  OBJECT-TYPE
	SYNTAX  INTEGER {
	                 swDwnLoad     (1),
					 configDwnLoad (2),
					 configUpLoad  (3),
					 coProcDwnLoad (4),
					 stateUpLoad   (5),
					 dwnLoadUserFile   (6),
					 upLoadUserFile    (7), 
					 swDwnLoadAndReset (8),
					 swUpLoad          (9),
					 noOp            (255)
					}
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
	"The command to be executed on fileName at fileServerIP."
	::= { fileTransfer 3 }
 
-- tftp  group  

tftpRetryTimeOut OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
        " General Retransmission time-out value (seconds) "
    -- DEFVAL  { 15 }
    ::= { fileTransfer 4 }

tftpTotalTimeOut OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
        " Total Retransmission time-out value (seconds) "
    -- DEFVAL  { 60 }
    ::= { fileTransfer 5 }

tftpStatus OBJECT-TYPE
    SYNTAX  INTEGER {
		noOp(2),
		connecting(3),
		transferringData(4),
		endedTimeOut(5),
		endedOk(6),
		error(7)
	}
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "Status of tftp session. When a session ended with success,
    the tftpStatus should be endedOk(6). Before restarting a
    tftp session, the NMS should set the tftpStatus to noOp(2).
    That's the reason of MAX-ACCESS read-write to this field."
    DEFVAL  { noOp}
    ::= { fileTransfer 6 }

tftpError OBJECT-TYPE
    SYNTAX  OCTET STRING ( SIZE(2) )
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
    " The MSB represents the standard error code.
    The LSB represents the private error code.
    0x0000 is No Error
    0x0100 is File Not Found
    0x0400 is Illegal TFTP operation
    0x0500 is Unknown transfer ID
    0x0001 is Server Overflow
    0x0002 is No empty UDP port
    0x0003 is No empty connection
    0x0004 is Illegal File Mode
    0x0007 is Illegal PDU size "
    DEFVAL  { '0000'h }
    ::= { fileTransfer 7 }

fileTransferToSubSystems OBJECT-TYPE
    SYNTAX  OCTET STRING 
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    " This object represents the sub-systems the fileTransCmd 
      refers to. It should be used when a system is divided 
      to sub-systems and each sub-system (or part of them) can 
	  have a different SW/Configuration.

	  Each bit of this object will represent one of the sub-systems.
	  Bit='1' - APPLY to respective sub-system
	  Bit='0' - DO NOT APPLY to respective sub-system

	  For the meaning of each bit, see product's specification.
	  User will select the sub-systems envolved by filling-in the bits
      that represent these sub-systems.
      In this case, the file represented by 'fileName' will 
	  include several parts, each representing one of the sub-systems.
	  The agent will refer only to the part/s indicated by this object.

      0 Octet Strings = not applicable  
      DEFVAL = 0h	for  the products that support this object."
    ::= { fileTransfer 8 }


fileNameWithinProduct  OBJECT-TYPE
	SYNTAX  DisplayString
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
	"The file name used by the product within the product file system."
	::= { fileTransfer 9 }

--Internal SW Download table

intSwdlTable  OBJECT-TYPE 
      SYNTAX SEQUENCE OF IntSwdlEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
      "This parameters table is for 
       internal Software down load. It also includes data 
       about all files contained in the Object from which 
       down-load is performed."
      ::= { fileTransfer 10 }

intSwdlEntry OBJECT-TYPE
      SYNTAX IntSwdlEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {intSwdlObjIdx, intSwdlFileIdx }
      ::= { intSwdlTable 1}

IntSwdlEntry ::=
      SEQUENCE {
      intSwdlObjIdx            Integer32,
	  intSwdlFileIdx           Integer32,
	  intSwdlFileName		   DisplayString,
	  intSwdlFileSwVer		   DisplayString,
	  intSwdlSwDate			   DisplayString,
	  intSwdlSize			   DisplayString,
	  intSwdlCmd			   INTEGER,
	  intSwdlToSubSystem	   OCTET STRING
      }

intSwdlObjIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The index of the object from which down-load is performed."
      ::= {intSwdlEntry 1}

intSwdlFileIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The index of the files included in intSwdlObjIdx.
       One of these files can be selected to be internally 
       downloaded."
      ::= {intSwdlEntry 2}

intSwdlFileName OBJECT-TYPE
      SYNTAX  	 DisplayString
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The name of the file."
      ::= {intSwdlEntry 3}

intSwdlFileSwVer OBJECT-TYPE
      SYNTAX  	 DisplayString
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The software version of the file."
      ::= {intSwdlEntry 4}

intSwdlSwDate OBJECT-TYPE
      SYNTAX  	 DisplayString
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The software version date of the file."
      ::= {intSwdlEntry 5}

intSwdlSize OBJECT-TYPE
      SYNTAX  	 DisplayString
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The size of the file."
      ::= {intSwdlEntry 6}

intSwdlCmd OBJECT-TYPE
      SYNTAX  	  INTEGER
	  				{
					notApplicable		(1),
					off		(2),
					on		(3)
					}
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The command to down-load a SW file to an object.
       The Agent will change the value of this MIB object to off(2) 
	  automatically, after accepting the command."
      ::= {intSwdlEntry 7}

intSwdlToSubSystem	OBJECT-TYPE   
      SYNTAX  OCTET STRING
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      " This object defines the subsystem for download.
       Bit='1'- APPLY to respective sub system.
       Bit='0'- DO NOT APPLY to respective sub system.
       For more details see product specification. 
       For every octet bit0=LSB, bit7=MSB"
      ::= { intSwdlEntry  8 }

--SW Download Status table

swdlStatusTable  OBJECT-TYPE 
      SYNTAX SEQUENCE OF SwdlStatusEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
      "This parameters table is for software download status. 
       It also includes data about the files down-loaded or 
       attempted to be down-loaded."
      ::= { fileTransfer 11 }

swdlStatusEntry OBJECT-TYPE
      SYNTAX SwdlStatusEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {swdlStatusTypeIdx, swdlStatusIdx }
      ::= { swdlStatusTable 1}

SwdlStatusEntry ::=
      SEQUENCE {
      swdlStatusTypeIdx            Integer32,
	  swdlStatusIdx       		   Integer32,
	  swdlStatusFileName		   DisplayString,
	  swdlStatusSlot			   DisplayString,
	  swdlStatusSubSystem		   DisplayString,
	  swdlStatusStatus			   Integer32,
	  swdlStatusTime			   DisplayString
	       }

swdlStatusTypeIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The index of the down-load type (e.g. external (1) or internal (2))."
      ::= {swdlStatusEntry 1}

swdlStatusIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The index of the status rows."
      ::= {swdlStatusEntry 2}

swdlStatusFileName OBJECT-TYPE
      SYNTAX  	 DisplayString
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The name of the file."
      ::= {swdlStatusEntry 3}

swdlStatusSlot OBJECT-TYPE
      SYNTAX  	 DisplayString
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The slot of the updated (or attempted to be updated) object."
      ::= {swdlStatusEntry 4}

 swdlStatusSubSystem OBJECT-TYPE
      SYNTAX  	 DisplayString
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The subsystem that updated (or attempted to be updated)."
      ::= {swdlStatusEntry 5}

swdlStatusStatus  OBJECT-TYPE
      SYNTAX  	  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The status of the down load process.
	  Value:  Fail (2), OK (3), InProcess (4)."
      ::= {swdlStatusEntry 6}

swdlStatusTime	   OBJECT-TYPE
          SYNTAX   DisplayString
          MAX-ACCESS  read-only
          STATUS  current
          DESCRIPTION
          "This MIB parameter indicates the time SW download was finished.
           The format shuld be YYYY-MM-DD, hh:mm:ss"

          ::= {swdlStatusEntry 7}

clearDwldStatusLog  OBJECT-TYPE
	SYNTAX  Integer32
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
	"This object clears the status log.
	  Value: off(2), external(3), internal(4)
	  The Agent will change the value of this MIB object to off(2) 
	  automatically, after accepting the command ."
	::= { fileTransfer 12 }


systemReset  OBJECT-TYPE
	SYNTAX  INTEGER	{
	                 off         (2),
					 on          (3), --HW
					 resetConfig (4)  
				    }
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
	"Reset action to be performed on the system."
	::= { agnt 13 }

systemTiming  OBJECT IDENTIFIER ::= { agnt 14 }

systemDate OBJECT-TYPE
        SYNTAX  DisplayString
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
           "System date."
        ::= { systemTiming 1 }
        
systemTime OBJECT-TYPE
        SYNTAX  DisplayString
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
           "System time."
        ::= { systemTiming 2 }


systemPort  OBJECT IDENTIFIER ::= { agnt 15 }

physicalConnectorTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PhysicalConnectorEntry
	MAX-ACCESS  not-accessible
	STATUS current
	DESCRIPTION
	"This table includes the connector type of ports or interfaces."
	::= {systemPort 1}

physicalConnectorEntry OBJECT-TYPE
	SYNTAX  PhysicalConnectorEntry
	MAX-ACCESS  not-accessible
	STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {portIdx}
	::= { physicalConnectorTable 1 }

PhysicalConnectorEntry  ::=
	    SEQUENCE {
	portIdx
	  Integer32,
	physicalConnector
	  INTEGER,
	portOptWaveLength
	  INTEGER,
	portOptMode
	  INTEGER,
	portBalance
	  INTEGER
	}

portIdx OBJECT-TYPE
	SYNTAX  Integer32 
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
	"This object is an index of the specific port or interface.
	 For a port, the index will be as agreed between agent and 
	 application.
	 For an interface, ifIndex may be used."
	::= { physicalConnectorEntry 1 }

physicalConnector OBJECT-TYPE
	SYNTAX  INTEGER 
	        {
			other (1),
			v35   (2),	  --34 pin female
			rs530 (3),	  --DB25
			x21   (4),	  --DB15
			bnc   (5),
			utp   (6),	  --RJ45
			aui   (7),
			rs422 (8),	  --DB25
			crossUtp (9), --RJ45
			rj45    (10),
			v24     (11), --DB25
			g703    (12), --TB5
			termBlock3AndRj45 (13),
			terminalBlock3    (14),
			terminalBlock5    (15),
			terminalBlock7    (16),
			db25              (17),
			db15              (18),
			rj45ethernet      (19),
			termBlock5AndRj45 (20),
			db9               (21),
			g703E1            (22),  --BNC-RJ45-BNC	
			g703E1-LTU        (23),  --BNC-RJ45-BNC
			sc                (24),	 --sc optical 
			st                (25),	 --st optical
			stl               (26),
			fc                (27),	 --fc optical
			tb5w              (28),  --Term-Block-5-Wire (for HCD)
			termBlock6AndRj45 (29),
			ethBnc            (30),
			scsi26            (31),  --SCSI with 26 pins
			eth4381           (32),  --RJ45 with two embeded LEDs
			twoBnc			  (33),  --Two BNC
			scsi50            (34),  --SCSI with 50 pins
			twoMiniBnc        (35),  --Two mini BNC
			sf1               (36),  --sf1=single fiber optical 
			terminalBlock4    (37),
			sf2         	  (38),  --sf2=single fiber optical
			db25Balanced      (39),  --DB25 Balanced
			v36               (40),
			block4W           (41),  --like in WR connector for Modems
			iripRj45          (42),
			irEthQRj45        (43),
			iripBnc           (44),
			rs530WA           (45),  --rs530/IR that solves a wander problem for SDH network	 
			v35WA             (46),  --v35/IR that solves a wander problem for SDH network
			irEthQBnc         (47),
			v35Db25           (48),  --V.35 with connector DB25
			rj11              (49),  --Used for FXS & FXO 	 
			mtrj              (50),  --optical
			lc                (51),  --optical
			terminalBlock2    (52),
			irEth10s100       (53),  --IR-ETH 10/100
			scsi68            (54),  -- SCSI 68 pins 
			sf3				  (55),  -- sf3=single fiber of sc optical  
			fcLH			  (56),  -- fc Long Haul
			telco50           (57),  -- TELCO 50
			telco64			  (58),	 -- TELCO 64
			irEthQN			  (59),
			none             (255)    	
			}	 
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
	"The connector of the port/interface.
	 other - none of the specified connectors
	 none -  no connector."
	::= { physicalConnectorEntry 2 }

portOptWaveLength OBJECT-TYPE
    SYNTAX  INTEGER {
		notApplicable(1),
		nm850(2),
		nm1300(3),
		nm1300Laser(4),
		nm1550Laser(5)
	}
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
     "Wave Length of an Optical interface/port in [nm] and specification if 
      Laser or not.
      notApplicable - for non-optical ports."
     ::= { physicalConnectorEntry 3 }

portOptMode OBJECT-TYPE
    SYNTAX  INTEGER {
		notApplicable(1),
		singleMode(2),
		multiMode(3)	   
	}
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
     "Laser Mode of an Optical Laser interface/port.
       notApplicable - for non-Laser ports."
     ::= { physicalConnectorEntry 4 }

portBalance OBJECT-TYPE
    SYNTAX  INTEGER {
      notApplicable (1), 
      unbalanced    (2),
      balanced      (3)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object is according to the port Impedance.
       For T1 - always balanced.
       For E1 - there are different impedance values for balanced
	            and unbalanced."
     ::= { physicalConnectorEntry 5 }


prtSupervisory  OBJECT IDENTIFIER ::= { systemPort 2 }


prtSpTable OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtSpEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "A table."
	::=  {prtSupervisory 1}

prtSpEntry OBJECT-TYPE
      SYNTAX PrtSpEntry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
      "Supervisory port parameter table."
      INDEX {prtSupervisoryIndex }
      ::= { prtSpTable 1}

PrtSpEntry ::=
      SEQUENCE {
      prtSupervisoryIndex       Integer32,
	  prtSupervisoryRate        INTEGER,
	  prtSupervisoryDataBits    INTEGER,
	  prtSupervisoryParity      INTEGER,
	  prtSupervisoryStopBits    INTEGER,
	  prtSupervisoryUsage       INTEGER,
	  prtSupervisoryInterface   INTEGER,
	  prtSupervisoryCTS		    INTEGER,
	  prtSupervisoryDcdDelay    INTEGER,
	  prtSupervisoryDSR		    INTEGER,
	  prtSupervisoryRoutProtocol   INTEGER
      }				  

prtSupervisoryIndex OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The SP port index.
       For some products, having modules (cards): 
       The LS byte of the integer is the port index 1..255. 
       The MS byte is different than 0 only if the port belongs to 
       a module. In	that case it is the module number.
       For other products' index see their specification."
      ::= { prtSpEntry 1}

prtSupervisoryRate     OBJECT-TYPE
      SYNTAX  INTEGER
	      {
        auto      (1),
        s300bps   (2),
        s1200bps  (3),
        s2400bps  (4),
        s4800bps  (5),
        s9600bps  (6),
        s19200bps (7),
        s38400bps (8),
        s57600bps (9),
        s115200bps (10)
	      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the operation rate (speed) of the 
       port.
       auto - automatic rate selection, by the agent."
      ::= { prtSpEntry 2}

prtSupervisoryDataBits OBJECT-TYPE
      SYNTAX  INTEGER
	      {
        dataBits7 (1),
        dataBits8 (2)
	      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the number of data bits in an async 
       frame"
      ::= { prtSpEntry 3}

prtSupervisoryParity OBJECT-TYPE
      SYNTAX  INTEGER
	      {
        none  (1),
        odd   (2),
        even  (3)
	      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the parity mode in an async frame"
      ::= { prtSpEntry 4}

prtSupervisoryStopBits OBJECT-TYPE
      SYNTAX  INTEGER
	      {
		notApplicable  (1),
        stopBits1      (2),
        stopBits1dot5  (3),
        stopBits2      (4)
	      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the parity mode in an async frame."
      ::= { prtSpEntry 5}

prtSupervisoryUsage OBJECT-TYPE
      SYNTAX  INTEGER
	      {
		unknown (1),
		noUse   (2),
		terminal(3),
		nmsSlip (4),
		nmsPpp  (5),
		muxSlip (6),
		muxPpp  (7),
		dialOut (8)
	      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the usage of the SP port."
      ::= { prtSpEntry 6}

prtSupervisoryInterface OBJECT-TYPE
      SYNTAX  INTEGER
	      {
		  notApplicable(1),
          dce  (2),
          dte  (3)
	      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the supervisory port interface."
      ::= { prtSpEntry 7}

prtSupervisoryCTS OBJECT-TYPE
      SYNTAX  INTEGER
	      {
          	notApplicable   (1),
          	on            	(2),        --Old value for DCE.
			rts           	(3),        --Old value for DCE 
			dteWait         (4),        --DTE will wait for CTS to become active before transmit date.
			dteIgnore       (5)         --DTE will Ignore CTS signal and will transmit date anyway.
	      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
	  "CTS line state." 
      ::= { prtSpEntry 8}

prtSupervisoryDcdDelay OBJECT-TYPE
      SYNTAX  INTEGER
	      {
          notApplicable (1),
          d0   (2),
          d10  (3),
		  d50  (4),
		  d100 (5),
		  d200 (6),
		  d300 (7)
	      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
	  "DCD delay in msec." 
      ::= { prtSpEntry 9}

prtSupervisoryDSR OBJECT-TYPE
      SYNTAX  INTEGER
	      {
          notApplicable (1),
          on   (2),
          dtr  (3)
	      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
	  "DSR line state." 
      ::= { prtSpEntry 10}

prtSupervisoryRoutProtocol OBJECT-TYPE
      SYNTAX  INTEGER
       {
        notApplicable (1),
  		none          (2),
        proprietary   (3),
        rip2          (4)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This attribute indicates the routing protocol of the port.
       notApplicable - for DP."
      ::= { prtSpEntry 11}

--Port Performance Data

prtPerformance  OBJECT IDENTIFIER ::= { systemPort 3 }

prtPerfTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PrtPerfEntry
	MAX-ACCESS  not-accessible
	STATUS current
	DESCRIPTION
	"This table includes G.826 ports or interfaces."
	::= {prtPerformance 1}

prtPerfEntry OBJECT-TYPE
	SYNTAX  PrtPerfEntry
	MAX-ACCESS  not-accessible
	STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtPerfIdx, prtPerfPeriodRef}
	::= { prtPerfTable 1 }

PrtPerfEntry  ::=
	    SEQUENCE {
	prtPerfIdx
	  Integer32,
	prtPerfPeriodRef
	  INTEGER,
	prtPerfElapsedTime
	  Integer32,
	prtPerfUAS
	  Integer32,
	prtPerfES
	  Integer32,
	prtPerfSES
	  Integer32,
	prtPerfBBE
	  Integer32,
	prtPerfBlocksPerSec
	  Integer32,
	prtPerfTimeTag
	  TimeTicks,
	prtPerfSaveAndResetCmd
	  INTEGER
	  }

prtPerfIdx OBJECT-TYPE
	SYNTAX  Integer32 
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
	"This object is an index of the specific port or interface.
	 For a port, the index will be as agreed between agent and 
	 application.
	 For an interface, ifIndex may be used."
	::= { prtPerfEntry 1 }

prtPerfPeriodRef OBJECT-TYPE
	SYNTAX  INTEGER 
	      {
          currentPeriod (1),
          lastPeriod    (2)
	      }
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION
	"This object is an index that specifies which period of time, the next
	 5 objects refer to.
	 currentPeriod - the period since last prtPerfSaveAndResetCmd received or
	           since Start-up (if no prtPerfSaveAndResetCmd was received since
	           Start-up) until now.
	 lastPeriod - the period between last two commands of prtPerfSaveAndResetCmd.
	           - If only one command occured since Start-up: the period between 
	             Start-up and last command.
	           - If no command occured since Start-up: this period will not 
	             actually exist. In this case, he following 5 objects will be 0."
	::= { prtPerfEntry 2 }

prtPerfElapsedTime OBJECT-TYPE
	SYNTAX  Integer32 
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION
	"Elapsed Time in seconds.
	 - for prtPerfPeriodRef=currentPeriod:
	   The period since last prtPerfSaveAndResetCmd received or	since Start-up 
	   (if no prtPerfSaveAndResetCmd was received since	Start-up) until now.
	 - for prtPerfPeriodRef=lastPeriod:
	   The value of prtPerfElapsedTime when last prtPerfSaveAndResetCmd
	   was received."
	::= { prtPerfEntry 3 }

prtPerfUAS OBJECT-TYPE
	SYNTAX  Integer32 
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION
	"Number of Unavailable Seconds for the reference period (prtPerfPeriodRef)."
	::= { prtPerfEntry 4 }

prtPerfES OBJECT-TYPE
	SYNTAX  Integer32 
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION
	"Number of Errored Seconds for the reference period (prtPerfPeriodRef)."
	::= { prtPerfEntry 5 }

prtPerfSES OBJECT-TYPE
	SYNTAX  Integer32 
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION
	"Number of Severely Errored Seconds for the reference period (prtPerfPeriodRef)."
	::= { prtPerfEntry 6 }

prtPerfBBE OBJECT-TYPE
	SYNTAX  Integer32 
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION
	"Number of Background Block (or Frame) Errors for the reference period 
	 (prtPerfPeriodRef)."
	::= { prtPerfEntry 7 }

prtPerfBlocksPerSec OBJECT-TYPE
	SYNTAX  Integer32 
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION
	"Blocks per second (or frames per second) of the port/interface indicated by 
	 portIdx. This object is constant for a certain port/interface.
	 It is not affected by the prtPerfPeriodRef index."
	::= { prtPerfEntry 8 }

prtPerfTimeTag OBJECT-TYPE
	SYNTAX  TimeTicks 
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION
	"Time Tag of Last Period: sysUpTime when last prtPerfSaveAndResetCmd was
	 executed.
	 This object is applicable only for prtPerfPeriodRef=lastPeriod.
	 For prtPerfPeriodRef=currentPeriod, the value will always be 0."
	::= { prtPerfEntry 9 }

prtPerfSaveAndResetCmd OBJECT-TYPE
    SYNTAX   INTEGER
	      {
    		off(2),
	    	on (3)
	      }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "A command per port/interface, to Save data of Current Period in Last Period
     data-set and start a new counting period for Current Period.
     This object is applicable only for prtPerfPeriodRef=currentPeriod.
     Setting this object to on(3) for prtPerfPeriodRef=last, will cause the agent
     to return: Bad Value response.
     When setting validly this object to on(3), agent will perform the required 
     command and will reset automatically the value of this object to off(2).
     Setting this object to off(2), will do nothing."
    ::= { prtPerfEntry 10 }

--Port Test Data

prtTest OBJECT IDENTIFIER ::= { systemPort 4 }

prtTestTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PrtTestEntry
	MAX-ACCESS  not-accessible
	STATUS current
	DESCRIPTION
	"This table includes test data for ports or interfaces."
	::= {prtTest 1}

prtTestEntry OBJECT-TYPE
	SYNTAX  PrtTestEntry
	MAX-ACCESS  not-accessible
	STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtTestIdx}
	::= { prtTestTable 1 }

PrtTestEntry  ::=
	    SEQUENCE {
     	prtTestIdx
	    Integer32,
    	prtTestCmdAndStatus
        Integer32,
    	prtBertCounter
        Integer32,
		prtTestInitiator
		INTEGER,
		prtTestTimeout
		Integer32
        } 

prtTestIdx OBJECT-TYPE
	SYNTAX  Integer32  
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
	"This object is an index of the specific port or interface.
	 For a port, the index will be as agreed between agent and 
	 application.
	 For an interface, ifIndex may be used."
	::= { prtTestEntry 1 }

prtTestCmdAndStatus OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Setting this object to a value as detailed further on 
       (except 0) will initiate a test on the specific port. 
       The test/s requested will be set according to the respective
       bit. The value of this object will be a sum of (2**n), where n is
       the Bit:
         TEST                  BIT	                     VALUE
        -----------            ---						------
        reserved                0						   1
		PayloadLoop=RLB     	1 (=Remote Loopback)	   2
        LineLoop=DIG            2 (=Digital)			   4
        OtherLoop               3						   8
        InwardLoop=LLB          4 (=Local Loopback)       16
        BERT                    5						  32
        LC                      6                         64
		ToneInjection			7						 128
		Inband 				    8			   			 256

        e.g : If the requested value is 20 -> 010100  ->
              Bits 2 & 4 are set -> the requested tests are :
                                    LineLoopback=DIG
                                    InwardLoopback=LLB
                                      
       Not all tests combinations are valid.
	   For valid test combination, see each product's specification.
	   For LRS52, only single test is allowed simultaneously

       The terminology and order of the first tests (except BERT) 
       is according to the one used for Test Status of DS1 and DS3 standards.
	   The notations : RLB, LLB, DIG are the most used in RAD's products, but they 
	   can be different. For exact definition see product's spec. 

       Setting this object to stop (value=0 ; all bits are 0), 
       will stop all the user requested tests running on the 
       selected port.

       When no test is running on the port, the Get value (test status)
	   will be 0.

	   PayloadLoop=RLB
	     The received signal at this interface is looped
	     through the device.  Typically the received signal
	     is looped back for retransmission after it has
	     passed through the device's framing function.

	   LineLoop=DIG
	     The received signal at this interface does not
	     go through the device (minimum penetration) but
	     is looped back out.

	   OtherLoop
	     Loopbacks that are not defined here.

	   InwardLoop=LLB 
	     The sent signal at this interface is looped back
	     through the device.

	   LC
	     This loop is applicable only for HSSI interface, towards the router .
	   
	   ToneInjection
		 This loop is applicable for analog voice (like FXS)."

   	  ::= { prtTestEntry 2 }

prtBertCounter   OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates the number of BERT errors encountered
       during the BERT operation.
       It is valid only when BERT (Bit Error Rate Test) is active on the 
       specific port.
       The Counter starts from zero (0) anytime BERT is initiated."
      ::= { prtTestEntry 3}

prtTestInitiator OBJECT-TYPE
    SYNTAX   INTEGER
	      {
    		unknown   (1),
    		user      (2),
	    	remoteUnit(3),
			dteRouter (4)
	      }
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
    "This object indicates who initiated this port's test/s."
    ::= { prtTestEntry 4 }

prtTestTimeout OBJECT-TYPE
   SYNTAX   Integer32  (0..4095)
   MAX-ACCESS  read-write
   STATUS  current
   DESCRIPTION
   "This object is applicable only when a single 
   test is running. It indicates the test 
   activation timeout in minutes.
   When the timeout expires, the test is stopped.
   Value of 0 indicates test may run Forever "
   ::= { prtTestEntry 5 }

--Port General Parameters

prtParam OBJECT IDENTIFIER ::= { systemPort 5 }

prtParamTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PrtParamEntry
	MAX-ACCESS  not-accessible
	STATUS current
	DESCRIPTION
	"This table includes general port parameters. The meaning is
	 different for every product that supports it due to a general
     parameter - prtControlCnfg.
	 
	 For ACE2002:
	 -This table is used as a mechanism to create the next interface index.
      The algorithm description: 
      The NMS will send the agent the following get command: get(nextIfIndex.index), 
      where index=interface on which the new index is dependent on. 
      Upon this command the agent will generate and return the new index to the NMS.
     - This table is partially supported according to the interface type. 
       Upon getNext function the irrelevant parameters will be skipped."
	::= {prtParam 1}

prtParamEntry OBJECT-TYPE
	SYNTAX  PrtParamEntry
	MAX-ACCESS  not-accessible
	STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtParamIdx}
	::= { prtParamTable 1 }

PrtParamEntry  ::=
	    SEQUENCE {
	prtParamIdx
	  Integer32,
	prtControlCnfg
	  Integer32,
    prtParamClkSrc
	  INTEGER,
    prtParamPhantom
	  INTEGER,
    prtParamResetStatsCmd
	  INTEGER,
	prtParamLastResetStatsTime
	  TimeStamp,
	prtParamInterfaceType
	  INTEGER,
	prtParamClearAlarm
	  INTEGER,
	prtParamLeds
	  OCTET STRING
	}

prtParamIdx OBJECT-TYPE
	SYNTAX  Integer32 
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
	"This object is an index of the specific port or interface.
	 For a port, the index will be as agreed between agent and 
	 application.
	 For an interface, ifIndex may be used.
	 
	 For ACE2002:
	 This parameter is the physical layer ifIndex of the slot on 
     which the NMS requires the next interface index."
	::= { prtParamEntry 1 }

prtControlCnfg OBJECT-TYPE
	SYNTAX  Integer32 
	MAX-ACCESS  read-write
	STATUS current
	DESCRIPTION
	"This object may be used for port RW general parameter/s.
	 For detailed meaning, see product's spec.
	 Supported by: PRBi-E3/T3.
	 
	 For ACE2002:
	 This parameter will include the value of the new index 
	 generated by agent.
	 
	 For Optimux-T3 and OP-155-1:
	 This parameter will be used for Release Remote LLB Command:
	 on=2= Set value only. Command to release LLB of Remote Unit.
	       Agent will return automatically to 'off' value after performing
	       the command.
	 off=3=Get value only.
	 
	 
	 For LA140
	 This parameter will be used as EchoCanceler per timeslot
	 off = 2 Echo Canceler is disabled
	 on =  3 Echo Canceler is enabled 
	 
	 For FCD-155
	 This parameter will be used to select the port that is
	 clock source for a PDH port, when 2495.dsx1TransmitClockSource=throughTiming.
	 VC12/VT1.5 = 2
	 SDH/SONET  = 3
	 
	 For ACE-52
	 This parameter will be used as Transmit Frame Type, i.e. 
	 which type of frame the corresponding bridge port will transmit:
	 Untagged = 2
	 Tagged = 3 
	 ."
	::= { prtParamEntry 2 }

prtParamClkSrc OBJECT-TYPE
    SYNTAX  INTEGER {
       loopTiming    (1),
       localTiming   (2),
       throughTiming (3),
	   adaptive      (4),
	   master        (5),
	   fallback      (6),   
	   notApplicable (255)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
       "The source of Transmit Clock.
        'loopTiming' or 'loopback' indicates that the recovered receive clock 
         is used as the transmit clock.

        'localTiming' or 'internal' indicates that a local clock
         source is used or when an external clock is
         attached to the box containing the interface.

        'throughTiming' or 'external' indicates that recovered receive clock 
         from another card or interface is used as the transmit clock.
         
        'adaptive' indicates that the clock is recovered according
         to the received data flow rate. 

        'master' and 'fallback' values may be used RO to 
         indicate active clock."    
	::= { prtParamEntry 3 }


prtParamPhantom OBJECT-TYPE
    SYNTAX  INTEGER {
       notApplicable (1),
       disable       (2),
       enable        (3)
	}
	MAX-ACCESS  read-write
	STATUS current
	DESCRIPTION
	"Power feeding to another device."
	::= { prtParamEntry 4 }

prtParamResetStatsCmd OBJECT-TYPE
    SYNTAX  INTEGER {
       off(2),
	   on (3)
	}
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "Reset statistics of the selected port."
    ::= { prtParamEntry 5 }

prtParamLastResetStatsTime OBJECT-TYPE
     SYNTAX  TimeStamp
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
     "The value of MIB II's sysUpTime object at the last time that 
      prtParamResetStatsCmd was Set to on(3) for this port.  
      If prtParamResetStatsCmd was never Set to on(3) since last 
      re-initialization of the agent, then this object contains a zero value.
      This object enables calculating the running time of Statistics
      counters for this port, by: [sysUpTime-prtParamLastResetStatsTime].
      For some devices other types of 'Reset' may affect this parameter"
     ::= { prtParamEntry 6 }

prtParamInterfaceType OBJECT-TYPE
    SYNTAX  INTEGER {
	   notApplicable (1),
       e1            (2),
       t1            (3),
       fr            (4),
	   hdlc          (5)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
       "The type of the port."
	::= { prtParamEntry 7 }

prtParamClearAlarm OBJECT-TYPE
    SYNTAX  INTEGER {
       off (2),
       on  (3)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
       "Setting this attribute to ON, will enforce a clear 
       operation on the Port Alarms.
       Upon completion, the value will automatically change
       to off(2)."
	::= { prtParamEntry 8 }

prtParamLeds  OBJECT-TYPE
	SYNTAX  OCTET STRING
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
	"This entry specifies the LEDs status of the port.
	 Each led is represented by 4 bits where the first 2 bits
	 (left) specify  the status :
	 (00=NA, 01=OFF, 10=ON, 11=BLINK),
     and the next two bits (right) specify the color :
     (00=GREEN, 01=RED, 10=YELLOW, 11=GRAY).
     The order of the LEDS is from top to bottom, left to right:
     For each row starting from the top, 
     the LEDS are returned from left to right."
     ::= {prtParamEntry 9} 


prtIP OBJECT IDENTIFIER ::= { systemPort 6 }

prtIpParamTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PrtIpParamEntry
	MAX-ACCESS  not-accessible
	STATUS current
	DESCRIPTION  "A table - Parameters for IP Ports."
	::= {prtIP 1}

prtIpParamEntry OBJECT-TYPE
	SYNTAX  PrtIpParamEntry
	MAX-ACCESS  not-accessible
	STATUS current
	DESCRIPTION  "An entry in table."
	INDEX { prtIpParamConfigIdx, prtIpParamSlotIdx, prtIpParamIdx }
	::= { prtIpParamTable 1 }

PrtIpParamEntry  ::=
    SEQUENCE {
    prtIpParamConfigIdx	      Integer32,
    prtIpParamSlotIdx  	      Integer32,
    prtIpParamIdx             Integer32,
	prtIpParamHostIP	      IpAddress,
	prtIpParamHostMask	      IpAddress,
	prtIpParamDefaultGateway  IpAddress,
	prtIpParamMediaMode		  INTEGER,
	prtIpParamMediaRate		  INTEGER,
	prtIpParamMngVlanSupport  INTEGER,
	prtIpParamMngVlanId       Integer32,
	prtIpParamMngVlanPriority Integer32,
	prtIpParamRingMode		  INTEGER,
	prtIpParamProtIpEnable    INTEGER,
	prtIpParamTrafficPriority INTEGER,
	prtIpParamRemoteIP	      IpAddress,
	prtIpParamMaxTxBandwidth  INTEGER
	}

prtIpParamConfigIdx OBJECT-TYPE
	SYNTAX  Integer32 
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION 
	"This object indicates the Configuration number (1..255) 
     referred.
     Value of 255 specifies the TmpCnfg (Scratch).
     For products having Agent and Edit configurations, 
     Write operation for the table entries is allowed only to 
     Config=255."
	::= { prtIpParamEntry 1 }

prtIpParamSlotIdx OBJECT-TYPE
    SYNTAX  Integer32   
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
    "This object indicates a unique number of the slot position 
     in which the module is inserted.
     notApplicable = 255 (for products that don't have slots).
       
     For KM:
     kmxMlA (103),
     kmxMlB (104)."
    ::= { prtIpParamEntry 2 }

prtIpParamIdx OBJECT-TYPE
	SYNTAX  Integer32 
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
	"This object indicates a unique Port Index."
	::= { prtIpParamEntry 3 }

prtIpParamHostIP OBJECT-TYPE
    SYNTAX  IpAddress 
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "The host interface IP address."
    ::= { prtIpParamEntry 4 }

prtIpParamHostMask OBJECT-TYPE
    SYNTAX  IpAddress 
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "The host interface subnet mask."
    ::= { prtIpParamEntry 5 }

prtIpParamDefaultGateway OBJECT-TYPE
    SYNTAX  IpAddress
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "Default Gateway's IP Address."
    ::= { prtIpParamEntry 6 }

prtIpParamMediaMode OBJECT-TYPE
    SYNTAX  INTEGER
	{
       notApplicable (1),
       halfDuplex    (2),
       fullDuplex    (3) 
    }
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
    "This object indicates the real Media Mode."
    ::= { prtIpParamEntry 7 }

prtIpParamMediaRate OBJECT-TYPE
    SYNTAX  INTEGER
	{
       notApplicable (1),
       r10Mbps       (2),
       r100Mbps      (3) 
    }
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
    "This object indicates the real Media Rate (Mbps)."
    ::= { prtIpParamEntry 8 }

prtIpParamMngVlanSupport OBJECT-TYPE
    SYNTAX  INTEGER 
    {
    notApplicable(1),
    no		(2),
    yes	    (3)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "Management VLAN support (Tagging).
     no - No support of VLAN Tagging.
     yes - 4 VLAN bytes will be added to the frame."
    ::= { prtIpParamEntry 9 }

prtIpParamMngVlanId OBJECT-TYPE
     SYNTAX  Integer32 
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
     "Management VLAN ID."
     ::= { prtIpParamEntry 10 }
  
prtIpParamMngVlanPriority OBJECT-TYPE
     SYNTAX  Integer32 
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
     "Management VLAN Frame priority."
     ::= { prtIpParamEntry 11 }

prtIpParamRingMode OBJECT-TYPE
    SYNTAX  INTEGER
	{
       notApplicable (1),
       disable       (2),
       enable        (3) 
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "This object indicates If Ring Mode is enabled or not."
    ::= { prtIpParamEntry 12 }

prtIpParamProtIpEnable OBJECT-TYPE
    SYNTAX  INTEGER
	{
       notApplicable (1),
       disable       (2),
       enable        (3) 
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "This object indicates whether a list of Protected IP Addresses 
     is enabled or not. This object is applicable only if 
     prtIpParamRingMode=enable."
    ::= { prtIpParamEntry 13 }

prtIpParamTrafficPriority OBJECT-TYPE
    SYNTAX  INTEGER
	{
       notApplicable (1),
       low           (2),
       high          (3) 
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "This object indicates the traffic priority of this port."
    ::= { prtIpParamEntry 14 } 

prtIpParamRemoteIP  OBJECT-TYPE
    SYNTAX  IpAddress 
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "This is the IP Address of the remote device that is connected to the
     current device (Point to Point Application). It is used for sending OAM packets
     on the LAN to the remote side in order to check that the connection is OK."
    ::= { prtIpParamEntry 15 }


prtIpParamMaxTxBandwidth OBJECT-TYPE
    SYNTAX  INTEGER
	{
       full  (2),
       e1    (3),
	   t1    (4)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "This object shows the Max Bandwidth allowed on the LAN.
     Full - means that a Maximum of 100 Mega Byte Rate may go through the LAN.
	 e1(3) means that the maximum is an E1 rate. t1(4) is for a maximum of a T1 rate."
    ::= { prtIpParamEntry 16 } 



prtClkSrc OBJECT IDENTIFIER ::= { systemPort 7 }

prtClkSrcTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PrtClkSrcEntry
	MAX-ACCESS  not-accessible
	STATUS current
	DESCRIPTION  
	"A table - Parameters for  master and fallback 
     clock source of ports ."
	::= {prtClkSrc 1}

prtClkSrcEntry OBJECT-TYPE
    SYNTAX PrtClkSrcEntry
    MAX-ACCESS not-accessible
    STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtClkSrcCnfgIdx, prtClkSrcPrtIdx, prtClkSrcIdx}
    ::= { prtClkSrcTable 1}

PrtClkSrcEntry ::=
    SEQUENCE {
    prtClkSrcCnfgIdx   Integer32,
    prtClkSrcPrtIdx	   Integer32,
    prtClkSrcIdx       INTEGER,
    prtClkSrcMode      INTEGER,
    prtClkSrcPrt       Integer32
	}

prtClkSrcCnfgIdx OBJECT-TYPE
    SYNTAX Integer32 (1..255)
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION
    "This attribute indicates the Idx of the Cnfg(1..255) being 
     accessed ; Idx of 255 relates to the TmpCnfg."
    ::= { prtClkSrcEntry 1}

prtClkSrcPrtIdx OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
    "This object indicates a unique Port Index (receiving clock).
     Refer to device specification for port Index"
    ::= { prtClkSrcEntry 2}

prtClkSrcIdx OBJECT-TYPE
    SYNTAX  INTEGER 
    {
    master    (1),
    fallback  (2)
    }
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
    "An index in the table. 
     master   - refers Master clock parameters 
     fallback - refers Fallback clock parameters"
    ::= { prtClkSrcEntry 3}

prtClkSrcMode OBJECT-TYPE
    SYNTAX  INTEGER
    {
--  none            (1),
    internal        (2),
    rxClk           (3),
--  station         (4),
--  lbt             (5),
--  ntr             (6),
--	adaptive        (7),  
    notApplicable (255)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "This entry indicates the source the nodal timing is 
     locked to.	"
    ::= { prtClkSrcEntry 4}

prtClkSrcPrt OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "This entry is valid only when working in rxClk mode.
	 It specifies the port from which the clock willl be taken.
	 Refer to device specification for source port Index"      
    ::= { prtClkSrcEntry 5}


systemResetAllStatsCmd OBJECT-TYPE
      SYNTAX   INTEGER
	  {
      off(2),
	  on (3)
	  }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
       "Reset statistics of all ports and connections of the device."
      ::= { agnt 16 }

systemClearTablesCmd OBJECT-TYPE
      SYNTAX   INTEGER
	      {
    		off(2),
	    	tempCnfgTables (3)
	      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
       "tempCnfgTables - Set *RowStatus = destroy for all entries of 
                         some tables having *RowStatus object, for 
                         temporary configuration only! (255).
                         For the relevant tables, see product's specification.
                         This object should be used by WAN product applications 
                         before performing the Update operation, in order to clear 
                         old entries of these tables.
                         For MP-104/204 the entries will be destroyed for cnfg=1. 
        off - agent will automatically change to this value, after performing the 
              command. "
      ::= { agnt 17 }

systemParameter OBJECT-TYPE
      SYNTAX   Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
       "This parameter can be used for different purposes: 
        - TELNET session time-out in seconds.
	   	- Ace20: when trying to create row in a table that already
				 has row with the same values, if set of values has to be unique
				 in table, this attribute is set to the index of the existing row.
		- Optimux-T3: when CH interfaces are RJ-45, user can select via this
		         object, the interface type for each Group of channels: T1 or E1:
		         The selection will be a sum of the following Bits.
		         '0' = T1
		         '1' = E1
		         Bit    Group               Value for each Bit having '1'
				  1		  1 (CH-1..CH-8)        	  1
				  2		  2 (CH-9..CH-12)       	  2
				  3		  3 (CH-13..CH-20)	          4
				  4		  4 (CH-21..CH-28)	          8
				 Examples:
				 15 = all Groups are selected to be E1
				  6 = Group 2 and Group 3 are selected to be E1 
				     (Group 1 and Group 4 are T1).
		- FCD-A, FCD-M: user can select via this object the configuration
		         used for Get values of MSDSL parameters that don't have
		         configuration index.
		         1  =active configuration
		         255=temporary configuration.
		         Set of this object should be done before Getting the MSDSL 
		         RW parameters.
		- Ace2002: This parameter indicates the number of intervals that
		         were successfully uploaded upon statistics collection session.        
		- FCD-IP, WR, FCD-IPD, LA-240:
		         This parameter indicates whether Telnet Access is enabled/disabled:
		         Values:
				 2 - Telnet Access is Disabled.
				 3 - Telnet Access is Enabled. 				 
        -Vmux-110: This parameter value equals to maximum number of bundles.
		-Optimux-155: Simmilar usage to Optimux T3. user can select via this
		         object, interface type T1 or E1 for each Group of 
		         channels (LIU):  LIU group consists of 7 channels. 
		         Up to 12 LIUs are represented (84 T1 Channels).
                 The selection will be a sum of the 2**n
                 For each bit:'0' = T1 ,'1' = E1
		         Bit    Group              
				  1		  1 (CH-1 ..  CH-7)   
				  2		  2 (CH-8 .. CH-14)  
				  3		  3 (CH-15 ..CH-21) 
                   ...
				  9		  9 (CH-56.. CH-63) 
                   ...
				  10	  10 (CH-64..CH-70) 
				  11	  11 (CH-71..CH-77) 
				  12	  12 (CH-78..CH-84) "
       ::= { agnt 18 }

 
agnGlobalAlarmMask OBJECT-TYPE   
      SYNTAX OCTET STRING 
      MAX-ACCESS  read-write    
      STATUS  current
      DESCRIPTION
      "The value of this attribute determines the alarm traps the 
       agent should mask and not send to the managers.
       Each bit from a certain octet represents a certain alarm."
      ::= { agnt 19 }

alarmSeverity   OBJECT-TYPE
      	SYNTAX   INTEGER
	      	{
			event		(3),
			minor		(4),
			major		(5),
	    	warning		(6),
			critical	(7)
	  		}
      	MAX-ACCESS  read-only
      	STATUS  current
      	DESCRIPTION
       	"This object specifies the severity of the alarms."
      ::= { agnt 20 }

alarmState   OBJECT-TYPE
      	SYNTAX   INTEGER
	      	{
			off (2), 	-- End, 
			on  (3) 	-- Start.
	  		}
      	MAX-ACCESS  read-only
      	STATUS  current
      	DESCRIPTION
       "."
      ::= { agnt 21 }


agnTestStatus OBJECT-TYPE
	SYNTAX	INTEGER
		{
		 off			(2),
		 on 			(3)
		}

	MAX-ACCESS	read-only
	STATUS	current
	DESCRIPTION
	"Indicates the current test status (for all levels: system,
	   card, port).
       This attribute will be set to: 
         on(3): when there is at least one test	in progress on the
                system/card/port
		 off(2): when there is NO test in progress on the
    	         system/card/port" 
      ::= {agnt 22  }

systemSaveAndResetAllStatsCmd OBJECT-TYPE
      SYNTAX   INTEGER
	      {
    		off(2),
	    	on (3)
	      }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "on  - a command to Save data of Current Period in Last Period
           data-set and start a new counting period for Current Period.
     off - agent will automatically change to this value, after performing the 
           command."
      ::= { agnt 23 }

systemDefaultGateway OBJECT-TYPE
      SYNTAX   IpAddress
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "Default Gateway's IP Address."
      ::= { agnt 24 }

-- PS Table
systemPsTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF SystemPsEntry
	MAX-ACCESS  not-accessible
	STATUS current
	DESCRIPTION
	"This table describes the PS types of a device.
	Usage of this table is specified in the device's NMS SRS"
	::= { agnt 25 }

systemPsEntry OBJECT-TYPE
	SYNTAX  SystemPsEntry
	MAX-ACCESS  not-accessible
	STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {systemPsIndex1, systemPsIndex2}
	::= { systemPsTable 1 }

SystemPsEntry  ::=
	    SEQUENCE {
	systemPsIndex1
	  Integer32,
	systemPsIndex2
	  Integer32,
	systemPsType
	  INTEGER,
	systemPsStatus
	  INTEGER,
	systemPsHotSwap
	  INTEGER
	}

systemPsIndex1 OBJECT-TYPE
	SYNTAX  Integer32 
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
	"First Index. 
	In HUBs:
	1 = PS-A slot
	2 = PS-B slot.
	In SA units:
	1 = PS1
	2 = PS2
	Default = 1"
	::= { systemPsEntry 1 }

systemPsIndex2 OBJECT-TYPE
	SYNTAX  Integer32 
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
	"Second Index. 
	In HUBs:
	1 always.
    In SA units:
	1 = Local
	2 = Remote
	Default = 1."
	::= { systemPsEntry 2 }

systemPsType OBJECT-TYPE
      SYNTAX  INTEGER
	      {
		  none  (1),
	      ac    (2),
	      dc    (3),
		  acDc  (4),
		  acPF  (5),
		  dcPF  (6)
	      }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The type of PS, for a stand-alone product.
      acDc - AC with rj45 DC.
      acPF - Power Feeding (phantom) box that is feeding another box by external AC.
      dcPF - Power Feeding (phantom) box that is feeding another box by external DC."
      ::= { systemPsEntry 3 }

systemPsStatus OBJECT-TYPE
      SYNTAX  INTEGER
	      {
		  notApplicable  (1),
	      failed         (2),
	      ok             (3)
	      }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The Status of the PS unit."
      ::= { systemPsEntry 4 }

systemPsHotSwap	OBJECT-TYPE
      SYNTAX  INTEGER
	      {
		  notApplicable  (1),
	      fixed          (2),
	      hotSwap        (3)
	      }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "Is PS unit hot swap or fixed."
      ::= { systemPsEntry 5 }

agnFans OBJECT-TYPE
	SYNTAX  OCTET STRING
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
	"This entry specifies the FANs existence and status. 
	 Each fan will be represented by 2 bits,
	 where the first bit (right) will specify the existence:
	 (0= Not exist, 1=exist),
     and the left bit will specify it's status
     (0= OK, 1=FAIL), so for each fan:
     00 - FAN does not exist
     01 - FAN exists and OK
     11 - FAN exists and is Failed 
	 bits 0-1 are for first fan
	 bits 2-3 are for 2nd fan (if exists)."
     ::= { agnt 26 }

agnSendTrapParameter OBJECT-TYPE
	SYNTAX  Integer32
	MAX-ACCESS  read-write
	STATUS current
	DESCRIPTION
	"This object specifies if the agent will attach a specific
	parameter to a trap.
	
	For ACE2002 the agent will attach or not the openViewSeverity 
	parameter according to the value of this parameter:
	1 - will attach openViewSeverity.
	0 - will not attach openViewSeverity."
     ::= { agnt 27 }

agnSensorsStatus OBJECT-TYPE
	SYNTAX  OCTET STRING
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
	"This entry specifies the Sensors (Temperature sensors or others)
	 existence and status. 
	 Each sensor will be represented by 2 bits,
	 where the first bit (right) will specify the existence:
	 (0= Not exist, 1=exist),
     and the left bit will specify it's status
     (0= OK, 1=FAIL), so for each sensor:
     00 - sensor does not exist
     01 - sensor exists and status is OK
     11 - sensor exists and status is not OK 
                  ( e.g. temperature exceeds pre-defined threshold)
	 bits 0-1 are for first sensor
	 bits 2-3 are for 2nd sensor (if exists)
	 and so on...
	 Bit 0 is the LSB."
     ::= { agnt 28 }

agnStationClockCard OBJECT-TYPE
	SYNTAX  INTEGER
	{
	 notApplicable	(1),
	 notExist       (2),
	 notValid       (3),
	 ok             (4)
	 }
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
	"This entry specifies the station clock card
	 existence and status. 
     notExist - station clock card (piggy) does not exist.
     notValid - station clock card exists but clock status is not valid.
     ok       - station clock card exists, and its status is OK "
     ::= { agnt 29 }

xcIndexNext  OBJECT-TYPE
          SYNTAX         Integer32 (0..2147483647)
          MAX-ACCESS         read-only
          STATUS         current
          DESCRIPTION
           "This object contains an appropriate value to
            be used for xcIndex when creating
            entries in the xcTable.  The value
            0 indicates that no unassigned entries are
            available. To obtain the xcIndex
            value for a new entry, the manager issues a
            management protocol retrieval operation to obtain
            the current value of this object.  After each
            retrieval, the agent should modify the value to
            the next unassigned index.
            After a manager retrieves a value the agent will
            determine through its local policy when this index
            value will be made available for reuse."
          ::= { agnt 30 }

--XC Table
xcTable OBJECT-TYPE
      SYNTAX SEQUENCE OF XcEntry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
      "Configuration of system cross-connect entries.
      The table follows the behavior described in RFC 2515, 
      RFC 1604 regarding the creation deletion and modification 
      of an entry within the table."
      ::= { agnt 31 }

xcEntry OBJECT-TYPE
      SYNTAX XcEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX { xcIndex, xcIfIndex1, xcVpi, xcVci, xcIfIndex2 }
      ::= { xcTable 1}

XcEntry ::=
      SEQUENCE {
	 xcIndex            Integer32,
     xcIfIndex1   	    Integer32,
     xcVpi 	            Integer32,
     xcVci 	            Integer32,
     xcIfIndex2   	    Integer32,
	 xcRowStatus        RowStatus,
	 xcDescr            DisplayString,
     xcAdminStatus      INTEGER,
     xcOperStatus       INTEGER,
	 xcAttachedIfType   INTEGER,
	 xcInputPriority    Integer32,
	 xcBitMapping       Integer32
      }

xcIndex OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
      "Cross Connect Identifier."
      ::= { xcEntry 1 }

xcIfIndex1 OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
      "The interface Index from the ifTable, which identify one side 
      of the connection."
      ::= { xcEntry 2 }

xcVpi OBJECT-TYPE
      SYNTAX  Integer32 
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
      "The VPI value."
      ::= { xcEntry 3 }

xcVci OBJECT-TYPE
      SYNTAX  Integer32 
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
      "The VCI value."
      ::= { xcEntry 4 }

xcIfIndex2 OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
      "The interface Index from the ifTable, which identifies the other 
      side of the connection."
      ::= { xcEntry 5 }

xcRowStatus  OBJECT-TYPE
      SYNTAX  RowStatus
     MAX-ACCESS   read-create
     STATUS   current
     DESCRIPTION
     "This parameter allows NMS to create/delete entries of this table."
     ::= { xcEntry 6 }

xcDescr  OBJECT-TYPE
     SYNTAX  DisplayString
     MAX-ACCESS   read-create
     STATUS   current
     DESCRIPTION
     "A textual string containing information about the
      xc entry."
     ::= { xcEntry 7 }


xcAdminStatus OBJECT-TYPE
        SYNTAX   INTEGER {
           up(1),
           down(2)
            }
      MAX-ACCESS  read-create
      STATUS  current
      DESCRIPTION
      "The desired administrative status of this bi-directional 
      cross-connect."
      ::= { xcEntry 8 }

xcOperStatus OBJECT-TYPE
        SYNTAX   INTEGER {
           up(1),
           down(2),
           unknown(3)
           }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The operational status of this bi-directional cross-connect."
      ::= { xcEntry 9 }

xcAttachedIfType OBJECT-TYPE
        SYNTAX   INTEGER {
          notApplicable(1),
          free         (2),
          routerAtm    (3),
          lis          (4)
          }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates if the specific VCC is
      already attached to any interface, and indicates
      the type of the interface.
      This object's purpose is to ease the checking to 
      the NMS.
      notApplicable - used for entries that are not LAN (as HDLC), 
                      or when the VCC was attached to a bridge, or 
                      when this parameter is irrelevant.
      free          - the LAN VCC wasn't attached yet to any router 
                      interface. 
      routerAtm      - attached to an ATM router interface.
      lis           - attached to a LIS interface."
      ::= { xcEntry 10 }

xcInputPriority OBJECT-TYPE
        SYNTAX   Integer32  (1..4)
      MAX-ACCESS  read-create
      STATUS  current
      DESCRIPTION
      "This object is the priority, by which the LAN frames will be 
      internaly sent to the ATM HW. This parameter is applicable if 
      atmNteMdlInputPriorityMechanism=enabled.
      
      1 -  Highest priority. Will be the first to be sent to the ATM HW.
      4 -  Lowest priority. Will be the last to be sent to the ATM HW."
      ::= { xcEntry 11 }

xcBitMapping OBJECT-TYPE
        SYNTAX   Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object maps this entry to a bit of an octet string.
      For ACE2002 this object maps the LAN VCC to the bit of the 
      VLAN Port Lists. If the value is '0' then it means that 
      this VCC is not mapped to a port list or it may be an HDSL
      entry."
      ::= { xcEntry 12 }

systemModule  OBJECT IDENTIFIER ::= { agnt 32 }


modlParam  OBJECT IDENTIFIER ::= { systemModule 1 }

modlParamTable OBJECT-TYPE
      SYNTAX SEQUENCE OF ModlParamEntry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
      "This table include parameters for system modules."
      ::= { modlParam 1 }

modlParamEntry OBJECT-TYPE
      SYNTAX ModlParamEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX { modlParamIndex }
      ::= { modlParamTable 1}


ModlParamEntry ::=
      SEQUENCE {
	 modlParamIndex        Integer32,
     modlParamReset 	    INTEGER,
     modlParamSwdlStatus	INTEGER,
	 modlParamLeds          OCTET STRING
      }

modlParamIndex OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The module index.
       The index can be the slot number or any other module index as described
       in the specifications of the device.
       For Vmux-2100 device, the index will have values of: 1..4 for slots 1..4."
      ::= { modlParamEntry 1 }

modlParamReset  OBJECT-TYPE
	SYNTAX  INTEGER	{
	                 off         (2),
					 on          (3),
					 factory	 (4) 			 
				    }
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
	"Reset action to be performed on the module. 
	 Set the parameter will be done always to on(3) or factory (4). 
	 After performing the Reset operation, Agent will automatically set the parameter to off(2)."
	::= { modlParamEntry 2 }
		   
modlParamSwdlStatus  OBJECT-TYPE
    SYNTAX  INTEGER	{
	notApplicable	(1),
	off         	(2),
	inProcess   	(3) 
		    }
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
      "This parameter indicates whatever the swdl is in process or not."
    ::= {modlParamEntry 3}

modlParamLeds  OBJECT-TYPE
	SYNTAX  OCTET STRING
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
	"This entry specifies the LEDs status of the module.
	 Each led is represented by 4 bits where the first 2 bits (left) specify  the status :
	 (00=NA, 01=OFF, 10=ON, 11=BLINK),
     and the next two bits (right) specify the color :
     (00=GREEN, 01=RED, 10=YELLOW, 11=GRAY).
     The order of the LEDS is from top to bottom, left to right:
     For each row starting from the top, the LEDS are returned from left to right."
     ::= {modlParamEntry 4}

agnNearFarConnection OBJECT-TYPE   
      SYNTAX  INTEGER {
		 notApplicable	(1),
		 disconnected  	(2), 
		 connected 		(3)
		 		}
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This parameter describes the connection between near-end and far-end agents."   
      ::= { agnt 33 }

agnAccess OBJECT IDENTIFIER ::= {agnt 34} 

agnTelnetAccess OBJECT-TYPE
	SYNTAX  INTEGER
	{
	 disable       (2),
	 enable        (3),
	 managersOnly  (4)
	 }
	MAX-ACCESS  read-write
	STATUS current
	DESCRIPTION
	"Enable/Disable accessing the device via Telnet.
	
	 disable - no one will be allowed to access the device via Telnet.
	 enable - all users are allowed Telnet Access.
	 managersOnly - Only manager stations listed in the manager's list are allowed."
     ::= { agnAccess 1 }

agnWebAccess OBJECT-TYPE
	SYNTAX  INTEGER
	{
	 disable       (2),
	 enable        (3),
	 managersOnly  (4)
	 }
	MAX-ACCESS  read-write
	STATUS current
	DESCRIPTION
	"Enable/Disable accessing the device via Web.
	
	 disable - no one will be allowed to access the device via Web.
	 enable - all users are allowed Web Access.
	 managersOnly - Only manager stations listed in the manager's list are allowed."
     ::= { agnAccess 2 }



systemInterface	 OBJECT IDENTIFIER  ::=  { agnt 35 }

SysIfEntityType ::= INTEGER
--	STATUS  current
--	DESCRIPTION
--	"This type defines the Entity Type.
--   The values existing in IANAifType MIB
--	 should be taken from there only.
--	 Additional values can be added, starting from 1000 decimal,
--	 when necessary."
	{
		other(1),
        ethernetLan(6),
        atm(37),				
		fastEther(62),			-- Fast Ethernet (100BaseT)
        ipForward(142),			-- Router
		teLink(200),
		bridge(209)
 	}

-- Interface Configuration Table

ifCreateTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF IfCreateEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
	"The Interface Configuration Table.
	 This table enables to create inferfaces of Entities."
    ::= { systemInterface 1 }

ifCreateEntry OBJECT-TYPE
    SYNTAX  IfCreateEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
    "An entry in the Interface Configuration table."
    INDEX   { ifCreateEntityType , ifCreateEntityIdx ,
    			ifCreateNumber }
    ::= { ifCreateTable 1 }

IfCreateEntry ::=
    SEQUENCE {
        ifCreateEntityType			SysIfEntityType,
        ifCreateEntityIdx			Integer32,
		ifCreateNumber				Integer32,
		ifCreateRowStatus			RowStatus,
		ifCreateType				IANAifType,
		ifCreateIndex				Integer32
    }
		
ifCreateEntityType OBJECT-TYPE
    SYNTAX  SysIfEntityType
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
    "This object indicates the Entity Type."
    ::= { ifCreateEntry 1 }

ifCreateEntityIdx OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
    "This object indicates the Entity Index."
    ::= { ifCreateEntry 2 }

ifCreateNumber OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
    "This object indicates the Interface Number."
    ::= { ifCreateEntry 3 }
	
ifCreateRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
    "This object enables the user to 
     create/delete entries in this table."
    ::= { ifCreateEntry 4 }

ifCreateType OBJECT-TYPE
    SYNTAX  IANAifType
    MAX-ACCESS  read-create
    STATUS  current
    DESCRIPTION
    "This object indicates the Interface Type."
    ::= { ifCreateEntry 5 }

ifCreateIndex OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
    "This object indicates the ifIndex of the created Interface."
    ::= { ifCreateEntry 6 }

systemOam	 OBJECT IDENTIFIER  ::=  { agnt 36 }

systemOamTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF SystemOamEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
	"The OAM Configuration Table."
	::= { systemOam 1 }

systemOamEntry OBJECT-TYPE
    SYNTAX  SystemOamEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
    "An entry in the OAM table."
    INDEX   { systemOamCnfgIdx }
    ::= { systemOamTable 1 }

SystemOamEntry ::=
    SEQUENCE {
        systemOamCnfgIdx            Integer32,
        systemOamFrequency			Integer32,
		systemOamTimeoutCycles		Integer32		
    }

systemOamCnfgIdx OBJECT-TYPE
    SYNTAX Integer32 (1..255)
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION
    "This attribute indicates the Idx of the Cnfg(1..255) being 
     accessed ; Idx of 255 relates to the TmpCnfg."
    ::= {  systemOamEntry 1}

systemOamFrequency OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "Time in sec. between 2 OAM packets."
    ::= { systemOamEntry 2 }

systemOamTimeoutCycles OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "No. of cycles the agent will send OAM packets without receiving a response
     from the remote device before declaring that the connection to the remote side
     is down - Time Out."
    ::= { systemOamEntry 3 }

bitMappingTable OBJECT-TYPE
      SYNTAX SEQUENCE OF BitMappingEntry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
      "This table maps bits of an octet string to an interface.
      For ACE-2002 this table is used to map bits of VLAN port lists
      to LAN VCC's. This table is the opposite view of the xcTable for
      xcBitMapping. It is used to ease the bit translation for the NMS."
      ::= { agnt 38 }

bitMappingEntry OBJECT-TYPE
      SYNTAX BitMappingEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  
	"Each entry in the table describes a correlation of a bit location to 
	an interface.
	For ACE-2002 - Upon creation of a new LAN VCC the agent will add an 
	entry to this table that will define the bit location for that VCC."
	INDEX { bitMappingLocation }
      ::= { bitMappingTable 1}

BitMappingEntry ::=
      SEQUENCE {
	  bitMappingLocation       Integer32,
      bitMappingIndex          Integer32
      }

bitMappingLocation OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
      "The bit location in an octet string."
      ::= { bitMappingEntry 1 }

bitMappingIndex OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The interface index or any other index that should be mapped."
      ::= { bitMappingEntry 2 }

bitMappingView OBJECT-TYPE
      SYNTAX  OCTET STRING
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A view of the bitMappingTable in one object - each entry in the 
      biMappingTable will have the corresponding Bit of this object 
      (bitMappingLocation) = '1'.
      For ACE-2002 it is used to describe all the existing LAN VCC's
      So that the NMS can easily calculate which VCC's can be selected
      as members for a VLAN, instead of reading all the bitMapping Table."
      ::= { agnt 39 }



--TRAPS

--NOTIFICATIONS

systemsEvents OBJECT-IDENTITY
     STATUS  current
     DESCRIPTION
     "The events for RAD products."
     ::= { systems 0 }

tftpStatusChangeTrap  NOTIFICATION-TYPE
     OBJECTS       { tftpStatus }
     STATUS current
     DESCRIPTION     
     "This trap is sent whenever the status of tftp changed."
     ::= { systemsEvents 1 }

agnStatusChangeTrap  NOTIFICATION-TYPE
	OBJECTS		{agnIndication }
    STATUS current
	DESCRIPTION
	"This trap is sent whenever the state of the entity the agent is
	 responsible for changed.
	 TDM devices will send agnTestStatus variable to indicate the current test status."
	::= { systemsEvents 2 }

prtStatusChangeTrap  NOTIFICATION-TYPE
    STATUS current
	DESCRIPTION
	"This trap is sent whenever the state of a port changed.
	 Attached, will be parameter/s that indicate the new port status.
	 The attached variables will be specified in the specifications
	 of the products supporting this trap."
	::= { systemsEvents 3 }

swdlStatusResult	    NOTIFICATION-TYPE
	OBJECTS			{swdlStatusFileName}
    STATUS  current
	DESCRIPTION
	"This notification is sent when Software Down Load is finished.
	 The attached object indicates the File Name."
	::= { systemsEvents 4 }

intSwdlSlotFileMismatch	    NOTIFICATION-TYPE
	OBJECTS			{intSwdlFileName}
    STATUS  current
	DESCRIPTION
	"This notification is sent when the card in the chosen slot doesn't match 
	 the chosen file.
	 The attached object indicates the File Name."
	::= { systemsEvents 5 }

agnCounterChange  NOTIFICATION-TYPE
    STATUS  current
	DESCRIPTION
	"This notification is sent when the value of a specific Counter is changed.
	 Agent can send as attached object the updated Counter.
	 For details about this Counter and attached object, see spec of the relevant
	 application."
	::= { systemsEvents 6 }

prtClkSrcChangeTrap NOTIFICATION-TYPE
      STATUS  current
      DESCRIPTION
	  "This trap is sent upon any port clock change."
    ::= { systemsEvents 7 }

moduleFailTrap NOTIFICATION-TYPE
      STATUS  current
      DESCRIPTION
	  "This trap is sent upon a module failure."
    ::= { systemsEvents 8 }
	
moduleInitFailTrap NOTIFICATION-TYPE
    STATUS current
      DESCRIPTION
	  "This trap is sent upon a module initialization failure."
	::= { systemsEvents 9 }

clkSrcChangeTrap NOTIFICATION-TYPE
      STATUS  current
      DESCRIPTION
	  "This trap is sent upon any change in Clock Source."
    ::= { systemsEvents 10 }

agnUploadDataTrap  NOTIFICATION-TYPE
     STATUS current
     DESCRIPTION     
     "This trap is sent upon an upload data session termination.
     For more details see product specification."
     ::= { systemsEvents 11 }

enrollmentTrap  NOTIFICATION-TYPE
     STATUS current
     DESCRIPTION     
     "This trap is a periodically trap, which sent to manager 
     untill Agent get any response (Get or Set) from this manager."
     ::= { systemsEvents 12 }

agnPowerFailureTrap  NOTIFICATION-TYPE
     STATUS current
     DESCRIPTION     
     "This trap is sent upon power failure. It is applicable for 
     the following devices:
     1. Devices having one PS unit, which sense the failure in advance,
        and still have time to send this trap before it goes off.
     2. Devices having 2 PS units and send this trap in order to notify a
        failure in one of the units."
     ::= { systemsEvents 13 }

-- 
-- file :v:\doc\rdv\mib\ver495\radds1.txt
-- 
-- RAD-DS1-MIB DEFINITIONS ::= BEGIN

--Title:    RAD-DS1   MIB
--
-- Copyright 1998 RAD Data Communications, Ltd.
-- All Rights Reserved.  

-- IMPORTS
-- PerfCurrentCount, PerfIntervalCount	FROM PerfHist-TC-MIB;

--      OBJECT-TYPE                     FROM RFC-1212
 --     radWan                          FROM RAD-GEN-MIB;
--                RAD-DS1 MIB   

--Title:     RAD's DS1 INTERFACE MIB
--Date:      03.02.98
--By:        Ilana Schvetz
--File:      radds1.mib

-- Last updated by Shlomo Shoham 20-Jan-2003

ds1Interface  OBJECT IDENTIFIER  ::=  {diverseIfWanGen 4}
prtDs1PerfHistory  OBJECT IDENTIFIER  ::=  {ds1Interface 1}

  --   Extension to the dsx1 current table
  
dsx1XCurrentTable  OBJECT-TYPE
       SYNTAX      SEQUENCE OF Dsx1XCurrentEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
       "A list of current statistics entries.  This table
        contains additional objects for the current table."
       ::= { prtDs1PerfHistory 2 }

dsx1XCurrentEntry OBJECT-TYPE
       SYNTAX  Dsx1XCurrentEntry 
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
       "An entry containing additional statistical counters
        applicable to a particular current table."
 --      AUGMENTS    { dsx1CurrentEntry }
         INDEX   { dsx1CurrentIndex }
       ::= { dsx1XCurrentTable 1 }

Dsx1XCurrentEntry     ::=
      SEQUENCE {
        dsx1CurrentLOS		    PerfCurrentCount,
        dsx1CurrentLOF		    PerfCurrentCount,
        dsx1CurrentLOC			PerfCurrentCount,
        dsx1CurrentAIS		    PerfCurrentCount,
        dsx1CurrentRAI			PerfCurrentCount,
        dsx1CurrentLOMF			PerfCurrentCount,
        dsx1CurrentFEBE			PerfCurrentCount,
        dsx1CurrentStatus		OCTET STRING,
		dsx1CurrentBPV			PerfCurrentCount,
		dsx1CurrentLOCRCMF	    PerfCurrentCount,
		dsx1CurrentLOFC			PerfCurrentCount,
		dsx1CurrentCRCErrors	PerfCurrentCount


}

dsx1CurrentLOS OBJECT-TYPE
        SYNTAX PerfCurrentCount
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
        "The counter associated with the number of LOS
         seconds, encountered by a DS1 interface in
         the current 15 minute interval."
        ::= { dsx1XCurrentEntry 1 }

dsx1CurrentLOF OBJECT-TYPE
        SYNTAX PerfCurrentCount
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
        "The counter associated with the number of LOF
         seconds, encountered by a DS1
         interface in the current 15 minute interval."
        ::= { dsx1XCurrentEntry 2 }


dsx1CurrentLOC OBJECT-TYPE
         SYNTAX PerfCurrentCount
         MAX-ACCESS  read-only
         STATUS  current
         DESCRIPTION
         " Loss Of Cell delineation. Counts number of cells the ATM UNI cells receiver
           lost cells delineation ."
         ::= { dsx1XCurrentEntry 3 }

dsx1CurrentAIS OBJECT-TYPE
        SYNTAX PerfCurrentCount
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
        "The counter associated with the number of AIS
         seconds, encountered by a DS1
         interface in the current 15 minute interval."
        ::= { dsx1XCurrentEntry 4 }

dsx1CurrentRAI OBJECT-TYPE
         SYNTAX PerfCurrentCount
         MAX-ACCESS  read-only
         STATUS  current
         DESCRIPTION
         "Remote Alarm Indication: Transmitted  in the outgoing direction
	      (toward the PABX) over FDL bits when the DS1 device detected 
          an incoming Loss Of Frame. Received from the far end (PABX) 
          over FDL when it detects a Loss of frame."
         ::= { dsx1XCurrentEntry 5 }

dsx1CurrentLOMF OBJECT-TYPE
         SYNTAX PerfCurrentCount
         MAX-ACCESS  read-only
         STATUS  current
         DESCRIPTION
         "Loss of Multi-Frame sequence  in E1 time slot 16."
         ::= { dsx1XCurrentEntry 6 }

dsx1CurrentFEBE OBJECT-TYPE
         SYNTAX PerfCurrentCount
         MAX-ACCESS  read-only
         STATUS  current
         DESCRIPTION
         "Far End Block Errors, as reported in the first bit
          of frames 13 and 15, on multiframe E1 lines with CRC4,
          in the current 15 minute interval."
         ::= { dsx1XCurrentEntry 7 }


dsx1CurrentStatus OBJECT-TYPE
	SYNTAX OCTET STRING  (SIZE (4))
         MAX-ACCESS  read-only
         STATUS  current
         DESCRIPTION
         "The statuses of the current interval:
           0 - Valid.
           1 - redundantLinkSwitch - the link has been switched 
               by a redundancy mechanism.
           2 - discontinuity - module was partialy out.
           4 - notValid - module is out."
         ::= { dsx1XCurrentEntry 8 }

dsx1CurrentBPV OBJECT-TYPE
         SYNTAX PerfCurrentCount
         MAX-ACCESS  read-only
         STATUS  current
         DESCRIPTION
         "The counter associated with the number of BPVs (Bi-Polar Violations)
          encountered by a DS1	interface in the current 15 minute interval."
         ::= { dsx1XCurrentEntry 9 }

dsx1CurrentLOCRCMF OBJECT-TYPE
         SYNTAX PerfCurrentCount
         MAX-ACCESS  read-only
         STATUS  current
         DESCRIPTION
         "Loss of CRC4 Multi-Frame sequence in E1.
          encountered in the current 15 minute interval"
         ::= { dsx1XCurrentEntry 10 }

dsx1CurrentLOFC	OBJECT-TYPE
         SYNTAX PerfCurrentCount 
         MAX-ACCESS  read-only
         STATUS  current
         DESCRIPTION
         "Counts the number of loss of frame events measured.
          encountered in the current 15 minute interval"
         ::= { dsx1XCurrentEntry 11 }

dsx1CurrentCRCErrors  OBJECT-TYPE
         SYNTAX PerfCurrentCount
         MAX-ACCESS  read-only
         STATUS  current
         DESCRIPTION
         "Counts the number of CRC error events,
          encountered in the current 15 minute interval."
         ::= { dsx1XCurrentEntry 12 }



-- Interval table

dsx1XIntervalTable OBJECT-TYPE
         SYNTAX  SEQUENCE OF Dsx1XIntervalEntry
         MAX-ACCESS  not-accessible
         STATUS  current
         DESCRIPTION
         " A list of Interval entries.  This table
           contains additional objects for the interval table."
         ::= { prtDs1PerfHistory 3 }

dsx1XIntervalEntry OBJECT-TYPE
         SYNTAX  Dsx1XIntervalEntry
         MAX-ACCESS  not-accessible
         STATUS  current
         DESCRIPTION
         "An entry containing additional statistical counters
          applicable to a particular interval table."
      -- AUGMENTS    { dsx1IntervalEntry }
         INDEX   { dsx1IntervalIndex, dsx1IntervalNumber }
         ::= { dsx1XIntervalTable 1 }

Dsx1XIntervalEntry     ::=
         SEQUENCE {
         dsx1IntervalLOS	   PerfIntervalCount,
         dsx1IntervalLOF	   PerfIntervalCount,
	     dsx1IntervalLOC       PerfIntervalCount,
         dsx1IntervalAIS	   PerfIntervalCount,
	     dsx1IntervalRAI	   PerfIntervalCount,
	     dsx1IntervalLOMF	   PerfIntervalCount,
		 dsx1IntervalFEBE	   PerfIntervalCount,
         dsx1IntervalStatus	   OCTET STRING,
         dsx1IntervalBPV	   PerfIntervalCount,
		 dsx1IntervalLOCRCMF   PerfIntervalCount,
		 dsx1IntervalLOFC	   PerfIntervalCount
}


dsx1IntervalLOS OBJECT-TYPE
         SYNTAX PerfIntervalCount
         MAX-ACCESS  read-only
         STATUS  current
         DESCRIPTION
          "The counter associated with the number of LOS
           seconds , encountered by a DS1 interface in
           one of the previous 96, individual 15 minute,
           intervals."
         ::= { dsx1XIntervalEntry 1 }

dsx1IntervalLOF OBJECT-TYPE
          SYNTAX PerfIntervalCount
          MAX-ACCESS  read-only
          STATUS  current
          DESCRIPTION
           "The counter associated with the number of OOF
            seconds, encountered by a DS1
            interface in one of the previous 96, individual 15
            minute, intervals."
          ::= { dsx1XIntervalEntry 2 }

dsx1IntervalLOC OBJECT-TYPE
         SYNTAX PerfIntervalCount
         MAX-ACCESS  read-only
         STATUS  current
         DESCRIPTION
          " Loss Of Cell delineation. Counts number of cells the ATM UNI cells receiver
            lost cells delineation ."
         ::= { dsx1XIntervalEntry 3 }

dsx1IntervalAIS OBJECT-TYPE
          SYNTAX PerfIntervalCount
          MAX-ACCESS  read-only
          STATUS  current
          DESCRIPTION
           "The counter associated with the number of AIS
            seconds, encountered by a SONET
            interface in one of the previous 96, individual 15
            minute, intervals."
          ::= { dsx1XIntervalEntry 4 }

dsx1IntervalRAI OBJECT-TYPE
           SYNTAX PerfIntervalCount
           MAX-ACCESS  read-only
           STATUS  current
           DESCRIPTION
           "Remote Alarm Indication: Transmitted  in the outgoing direction
	        (toward the PABX) over FDL bits when the DS1 device detected 
            an incoming Loss Of Frame. Received from the far end (PABX) 
            over FDL when it detects a Loss of frame."
           ::= { dsx1XIntervalEntry 5 }

dsx1IntervalLOMF OBJECT-TYPE
           SYNTAX PerfIntervalCount
           MAX-ACCESS  read-only
           STATUS  current
           DESCRIPTION
           "Loss of Multi-Frame sequence  in E1 time slot 16."
           ::= { dsx1XIntervalEntry 6 }

dsx1IntervalFEBE OBJECT-TYPE
          SYNTAX PerfIntervalCount
          MAX-ACCESS  read-only
          STATUS  current
          DESCRIPTION
          "Far End Block Errors, as reported in the first bit
           of frames 13 and 15, on multiframe E1 lines with CRC4,
           in one of the previous 96, individual, 15 minute intervals."
          ::= { dsx1XIntervalEntry 7 }

dsx1IntervalStatus OBJECT-TYPE
	SYNTAX OCTET STRING  (SIZE (4))
           MAX-ACCESS  read-only
           STATUS  current
           DESCRIPTION
            "The statuses of the current interval:
              0 - Valid.
              1 - redundantLinkSwitch - the link has been switched 
                  by a redundancy mechanism.
              2 - discontinuity - module was partialy out.
              4 - notValid - module is out."
           ::= { dsx1XIntervalEntry 8 }

dsx1IntervalBPV OBJECT-TYPE
         SYNTAX PerfIntervalCount
         MAX-ACCESS  read-only
         STATUS  current
         DESCRIPTION
         "The counter associated with the number of BPV (Bi-Polar Violations)
          encountered by a DS1	interface in one of the previous 96, 
          individual 15 minute, intervals."
         ::= { dsx1XIntervalEntry 9 }

dsx1IntervalLOCRCMF OBJECT-TYPE
         SYNTAX PerfIntervalCount
         MAX-ACCESS  read-only
         STATUS  current
         DESCRIPTION
         "Loss of CRC4 Multi-Frame sequence in E1."
         ::= { dsx1XIntervalEntry 10 }

dsx1IntervalLOFC OBJECT-TYPE
          SYNTAX PerfIntervalCount
          MAX-ACCESS  read-only
          STATUS  current
          DESCRIPTION
          "Counts the number of loss of frame events measured
          in one of the previous 96, individual 15 minute, intervals."
          ::= { dsx1XIntervalEntry 11 }


--   Extension to the dsx1 Total table
  
dsx1XTotalTable  OBJECT-TYPE
       SYNTAX      SEQUENCE OF Dsx1XTotalEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
       "A list of Total statistics entries.  This table
        contains additional objects for the Total table."
       ::= { prtDs1PerfHistory 4 }

dsx1XTotalEntry OBJECT-TYPE
       SYNTAX  Dsx1XTotalEntry 
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
       "An entry containing additional statistical counters
        applicable to a particular current table."
 --     AUGMENTS    { dsx1CurrentEntry }
        INDEX   { dsx1TotalIndex }
       ::= { dsx1XTotalTable 1 }

Dsx1XTotalEntry     ::=
      SEQUENCE {
	  dsx1TotalBPV			PerfTotalCount,
      dsx1TotalLOFC			PerfTotalCount
      }

dsx1TotalBPV OBJECT-TYPE
      SYNTAX PerfTotalCount
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The counter associated with the number of BPV (Bi-Polar Violations)
       encountered by a DS1	interface in the previous 24 hour interval.
       Invalid 15 minute intervals count as 0."
      ::= { dsx1XTotalEntry 9 }


dsx1TotalLOFC OBJECT-TYPE
      SYNTAX PerfTotalCount
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "The counter associated with the number loss of frames
       encountered by a DS1	interface in the previous 24 hour interval.
       Invalid 15 minute intervals count as 0."
      ::= { dsx1XTotalEntry 11 }


--   Extension to the DS1 Configuration Table
  
dsx1XConfigTable  OBJECT-TYPE
       SYNTAX      SEQUENCE OF Dsx1XConfigEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
               " An extension to the DS1 Configuration table."
       ::= { ds1Interface 2 }

dsx1XConfigEntry OBJECT-TYPE
       SYNTAX  Dsx1XConfigEntry 
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "An entry containing additional configuration
           parameters."
 --      AUGMENTS    { dsx1ConfigTable }
         INDEX   { dsx1LineIndex }
       ::= { dsx1XConfigTable 1 }

Dsx1XConfigEntry      ::=
       SEQUENCE {
         dsx1IdleCode		    	Integer32,
         dsx1LineMode		    	INTEGER,
         dsx1dBTxGain     			INTEGER,
         dsx1RxSensitivity			INTEGER,
         dsx1RestoreTime			INTEGER,
         dsx1TcFirstSignal			Integer32,
         dsx1TcSignal   			Integer32,
         dsx1TcPattern     			Integer32,
         dsx1Scramble     			INTEGER,
         dsx1LineAdaptiveTimingMode INTEGER,
		 dsx1TxClockSource          INTEGER,
		 dsx1AisEnable				INTEGER,
		 dsx1TsEchoCancel			OCTET STRING,
		 dsx1EchoCancelerModule     INTEGER,
         dsx1PortFunction 		    INTEGER,
		 dsx1PortMultiplier			INTEGER,
		 dsx1LeasedLine				INTEGER,	
		 dsx1CsuLoop				INTEGER
       }

dsx1IdleCode OBJECT-TYPE
         SYNTAX  Integer32
         MAX-ACCESS   read-write
         STATUS  current
         DESCRIPTION
	     "Byte pattern of the data received/transmitted in the 
	      E1T1 framer idle timeslots.
	      Valid range: (0 - FF HEX)."
         ::= { dsx1XConfigEntry 1 }

dsx1LineMode OBJECT-TYPE
          SYNTAX  INTEGER { 
          csu(1),
          dsu(2)
          }
          MAX-ACCESS  read-write
          STATUS  current
          DESCRIPTION
                  "T1 device operation mode. 
                   Valid for T1 only."
          ::= { dsx1XConfigEntry 2 }

dsx1dBTxGain OBJECT-TYPE
         SYNTAX  INTEGER { 
         notApplicable (1),
         neg75dB       (2),
         neg15dB       (3),
         neg225dB      (4),
		 zerodB	       (5)
         }
         MAX-ACCESS  read-write
         STATUS  current
         DESCRIPTION
                 "Transmit line Gain for T1 CSU line mode."
         ::= { dsx1XConfigEntry 3 }

dsx1RxSensitivity OBJECT-TYPE
        SYNTAX  INTEGER { 
		notApplicable  (1),
        neg10dB        (2),
        neg32dB        (3)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
        "Determine the maximum attenuation of the 
         receive signal that can be compensated for 
         by the interface receive path. Not applicable for T1."
        ::= { dsx1XConfigEntry 4 }

dsx1RestoreTime OBJECT-TYPE
        SYNTAX  INTEGER { 
        other(1),
        sec1(2),
        sec10(3)
        }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
        "Used to change the sync. algorithms to reduce the time 
         required for the port to return to normal operation after 
         a RED alarm."
        ::= { dsx1XConfigEntry 5 }

dsx1TcFirstSignal OBJECT-TYPE
        SYNTAX  Integer32
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
        "Trunk conditioning signal - value to be sent as a signal
         during the first 2.5 seconds after alarm detection.
		 Range is 0x0..0xF. 0xFF is a NULL value. Valid for T1 only."
        ::= { dsx1XConfigEntry 6 }

dsx1TcSignal OBJECT-TYPE
        SYNTAX  Integer32 
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
        "Trunk conditioning signal value after alarm detection. 
         Range is 0x1..0xF for E1, and 0x0..0xF for T1."
        ::= { dsx1XConfigEntry 7 }

dsx1TcPattern OBJECT-TYPE
       SYNTAX  Integer32
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
       "Trunk conditioning data pattern to be sent upon a DS0 fail.
	  	Range is 0x0..0xFF."
       ::= { dsx1XConfigEntry 8 }

dsx1Scramble  OBJECT-TYPE
       SYNTAX  INTEGER { 
       notApplicable (1),
       notActive     (2),
       active        (3)
       }
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
       "Scrambling is an operation that randomizes the bits 
        of the payload of the ATM cell by a polynom.
        This operation helps with the error detection mechanism
        of the HEC. Not applicable for E1.
        active - will scramble/descramble the payload ATM cell
        notActive - will not scramble/descramble. "
       ::= { dsx1XConfigEntry 9 }

dsx1LineAdaptiveTimingMode OBJECT-TYPE
       SYNTAX  INTEGER {
       off(1),
       on(2)
       }
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
       "Enables end to end clock synchronization.
        Default value - off."
       ::= { dsx1XConfigEntry 10 }

dsx1TxClockSource OBJECT-TYPE
       SYNTAX  INTEGER {
       loopTiming(1),
       localTiming(2),
       throughTiming(3),
	   adaptive(4)
       }
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
       "The source of Transmit Clock.
        'loopTiming' indicates that the recovered receive clock 
         is used as the transmit clock.

        'localTiming' indicates that a local clock
         source is used or when an external clock is
         attached to the box containing the interface.

        'throughTiming' indicates that recovered receive clock 
         from another interface is used as the transmit clock.
         
        'adaptive' indicates that the clock is recovered according
         to the received data flow rate. "
       ::= { dsx1XConfigEntry 11 }

dsx1AisEnable  OBJECT-TYPE
       SYNTAX  INTEGER {
       notApplicable(1),
       disable(2),
       enable(3)
       }
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
       "Enable/ disable AIS transmit when Ethernet cable (for TDMoIP) is out (disconnected)."
       ::= { dsx1XConfigEntry 12 }

dsx1TsEchoCancel OBJECT-TYPE
       SYNTAX OCTET STRING  (SIZE (4))
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
       "This parameter defines for each TS whether Echo-Cancellation is on.
	  	Each bit represents one TS as follow:
		First octet bit'0' = TS#1, bit'7' = TS#8, .. 2nd octet bit'0' = TS#9,.., 
		4th octet bit'7' = TS#32.
		Octets and bits order is from left to right:
		[31,30,..24]      [23..16]    [15..8]      [7..0]
		MSB       LSB 	 MSB	LSB	 MSB   LSB	  MSB	LSB
	  	
	  	For each bit values are:
         0 - Echo-Cancellation off.
         1 - Echo-Cancellation on."
       ::= { dsx1XConfigEntry 13 }

dsx1EchoCancelerModule OBJECT-TYPE
       SYNTAX  INTEGER { 
       notExist(2),
       exist(3)
       }
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
       "This parameter indicates whether echo-cancellation module
        exists for this line."
       ::= { dsx1XConfigEntry 14 }

dsx1PortFunction OBJECT-TYPE
       SYNTAX  INTEGER { 
	    notApplicable (1),	
	  	uni (2),
	  	ces (3),
	  	ima (4)
	    }
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
       "This object determines the ATM Mode over the 
        physical port.
        uni - The port will function as an ATM UNI.  
        ces - The port will function as a CES.
        ima - The port will function as an IMA-ATM."
       ::= { dsx1XConfigEntry 15 }

dsx1PortMultiplier OBJECT-TYPE
       SYNTAX  INTEGER { 
	    notApplicable (1),	
	  	r56 (2),
	  	r64 (3)
	    }
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
       "This object determines the data rate of each TS 
        (Kbps units). 
        This parameter is applicable for T1 only."
       ::= { dsx1XConfigEntry 16 }

dsx1LeasedLine OBJECT-TYPE
       SYNTAX  INTEGER { 
	    notApplicable (1),	
	  	disable (2),
	  	enable (3)
	    }
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
       "This parameter defines whether Line mode is regular (non Leased Line mode) 
       or transparent (Leased Line mode)."
       ::= { dsx1XConfigEntry 17 }

dsx1CsuLoop OBJECT-TYPE
       SYNTAX  INTEGER { 
	    notApplicable	(1),
       local	  	    (2),
	   transparent		(3)	    }
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
       "This parameter defines whether CSU loop will be done locally (by IPmux)
        or will be transferred to the TDM device."
       ::= { dsx1XConfigEntry 18 }



-- END
-- 
-- file :v:\doc\rdv\mib\Before~1\radds3.txt
-- 
-- RAD-DS3-MIB DEFINITIONS ::= BEGIN

--Title:    RAD-DS3   MIB
--
-- Copyright 1993 RAD Data Communications, Ltd.
-- All Rights Reserved.  

-- It is RAD's intent to encourage the widespread use of
-- this Specification in connection with the management of
-- RAD products. RAD grants vendors, end-users,
-- and other interested parties a non-exclusive license to
-- use this Specification in connection with the management
-- of RAD products.
-- This Specification is supplied "as is," and RAD makes
-- no warranty, either express or implied, as to the use,
-- operation, condition, or performance of the Specification.

-- IMPORTS
--      Gauge32                           FROM SNMPv2-SMI
--      ifIndex                         FROM SNMPv2-TC
--      OBJECT-TYPE                     FROM SNMPv2-SMI
 --     radWan                          FROM RAD-GEN-MIB;



--                RAD-DS3 MIB   

--Title:     RAD's DS3 INTERFACE MIB
--Version:   1.0
--Date:      13.10.96
--By:        Yair Arian
--File:      ds3.mib
--
--Last update: 27.01.98 by Ilana



ds3Interface  OBJECT IDENTIFIER  ::=  {diverseIfWanGen 3}

prtDs3PerfHistory  OBJECT IDENTIFIER  ::=  {ds3Interface 1}


          -- The DS3 Interface Table

          prtSDs3IfTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF PrtDs3IfEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "The DS3 interface table."
              ::= { prtDs3PerfHistory 1 }

          prtDs3IfEntry OBJECT-TYPE
              SYNTAX  PrtDs3IfEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "An entry in the DS3 interface table."
              INDEX   { ifIndex }
              ::= { prtSDs3IfTable 1 }

          PrtDs3IfEntry ::=
              SEQUENCE {
                  prtDs3IfTimeElapsed
                      Integer32,
                  prtDs3IfValidIntervals
                      Integer32
                     }

           prtDs3IfTimeElapsed OBJECT-TYPE
               SYNTAX  Integer32 (0..899)
               MAX-ACCESS  read-only
               STATUS  current
               DESCRIPTION
                       "The number of seconds that have elapsed since
                       the beginning of the near end current error-
                       measurement period."
              ::= { prtDs3IfEntry 1 }

          prtDs3IfValidIntervals OBJECT-TYPE
              SYNTAX  Integer32 (0..96)
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The number of previous near end intervals for
                      which valid data was collected.  The value will be
                      96 unless the interface was brought online within
                      the last 24 hours, in which case the value will be
                      the number of complete 15 minute near end
                      intervals since the interface has been online."
              ::= { prtDs3IfEntry 2 }


          -- The DS3 Current Table

          -- The DS3 Current table contains various statistics being
          -- collected for the current 15 minute interval.

          prtDs3CurrentTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF PrtDs3CurrentEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "The DS3 Current table."
              ::= { prtDs3PerfHistory 2 }

          prtDs3CurrentEntry OBJECT-TYPE
              SYNTAX  PrtDs3CurrentEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "An entry in the DS3 Current table."
              INDEX   { ifIndex }
              ::= { prtDs3CurrentTable 1 }

          PrtDs3CurrentEntry ::=
              SEQUENCE {
                  prtDs3CurrentLOS
                      Gauge32,
                  prtDs3CurrentOOF
                      Gauge32,
                  prtDs3CurrentLOC
                      Gauge32,
                  prtDs3CurrentAIS
                      Gauge32,
                  prtDs3CurrentRDI
                      Gauge32,
                  prtDs3CurrentUAS
                      Gauge32,
	              prtDs3CurrentBIP
                      Gauge32,
                  prtDs3CurrentFEBE
	                  Gauge32,
	              prtDs3CurrentSLM
	                  Gauge32,
                  prtDs3CurrentSES
                      Gauge32,
                  prtDs3CurrentES 
                      Gauge32,
                  prtDs3CurrentBitParity
                      Gauge32,
                  prtDs3CurrentPlcpLOF
                      Gauge32,
                  prtDs3CurrentPlcpRAI
                       Gauge32,
	              prtDs3CurrentPlcpBIP
                       Gauge32,
                  prtDs3CurrentPlcpFEBE
	                   Gauge32,
				 prtDs3CurrentBPV
				       Gauge32,
				 prtDs3CurrentLCE
				       Gauge32,
				  prtDs3CurrentStatus
				       OCTET STRING
}

          prtDs3CurrentLOS OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of LOS
                       seconds, encountered by a DS3 interface in
                      the current 15 minute interval."
              ::= { prtDs3CurrentEntry 1 }

          prtDs3CurrentOOF OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of OOF
                       seconds, encountered by a DS3
                       interface in the current 15 minute interval."
              ::= { prtDs3CurrentEntry 2 }

          prtDs3CurrentLOC OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of LOC
                      seconds, encountered by a DS3
                      interface in the current 15 minute interval."
              ::= { prtDs3CurrentEntry 3 }

          prtDs3CurrentAIS OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of AIS
                      seconds, encountered by a DS3
                      interface in the current 15 minute interval."
              ::= { prtDs3CurrentEntry 4 }

          prtDs3CurrentRDI OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of RDI
                      seconds, encountered by a DS3
                      interface."
              ::= { prtDs3CurrentEntry 5 }

          prtDs3CurrentUAS OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of UAS, 
                      encountered by a SONET interface."
              ::= { prtDs3CurrentEntry 6 }

        prtDs3CurrentBIP OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of 
                      BIP errors, encountered by a DS3
                      interface in the current 15 minute interval."
              ::= { prtDs3CurrentEntry 7 }

          prtDs3CurrentFEBE OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of 
                      FEBE errors, encountered by a DS3
                      interface in the current 15 minute interval."
              ::= { prtDs3CurrentEntry 8 }

          prtDs3CurrentSLM OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of SLM
                       seconds, encountered by an E3 (only )
                       interface in the current 15 minute interval."
              ::= { prtDs3CurrentEntry 9 }

        prtDs3CurrentSES OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of SES
                       encountered by a E3
                       interface in the current 15 minute interval."
	     ::= { prtDs3CurrentEntry 10 }

	  prtDs3CurrentES OBJECT-TYPE
	SYNTAX Gauge32 
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      " The number of Errored Seconds, encountered  by a
                      DS3 interface in the current 15 minute interval."
	::= { prtDs3CurrentEntry 11 }

     prtDs3CurrentBitParity OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "Bit Parity Error counter. Relevant to T3 only."
              ::= { prtDs3CurrentEntry 12 }

        prtDs3CurrentPlcpLOF OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of LOF
                      seconds, encountered by a DS3
                      interface in one of the previous 96, individual 15
                      minute, intervals. This counter is relevant for plcpInternal(5)
                       or plcpExternal(6) configuration If frame types only."
              ::= { prtDs3CurrentEntry 13 }

prtDs3CurrentPlcpRAI OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                    "Receiving Yellow/Remote Alarm Indication. This counter is 
                      relevant for PLCP (external/internal) frame types only."
              ::= { prtDs3CurrentEntry 14 }

      prtDs3CurrentPlcpBIP OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                    " The counter associated with the number of BIP errors, 
                      encountered by a DS3 interface in the current 15 minute 
                      interval. This counter is relevant for PLCP (external/internal) 
                      frame types only."
              ::= { prtDs3CurrentEntry 15 }

      prtDs3CurrentPlcpFEBE OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                    " The counter associated with the number of FEBE
                      errors, encountered by a DS3 interface in the current
                      15 minute interval. This counter is relevant for PLCP
                      (external/internal) frame types only."
              ::= { prtDs3CurrentEntry 16 }

      prtDs3CurrentBPV OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                    " Number of BPVs (Bi-Polar Violations) , encountered by a 
                      DS3 interface in the current 15 minute interval. 
                      This object is relevant only for Electrical Line
                      of Fomi-E3/T3."
              ::= { prtDs3CurrentEntry 17 }

      prtDs3CurrentLCE OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                    " Number of LCE (Link Code Errors)  encountered 
                      by a DS3 interface in the current 15 minute interval. 
                      This object is relevant only for Optical Links
                      of Fomi-E3/T3."
              ::= { prtDs3CurrentEntry 18 }

     prtDs3CurrentStatus OBJECT-TYPE
	          SYNTAX OCTET STRING  (SIZE (4))
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The statuses of the current interval:
                        0 - Valid.
                        1 - redundantLinkSwitch - the link has been switched 
                            by a redundancy mechanism.
                        2 - discontinuity - module was partialy out.
                        4 - notValid - module is out."
              ::= { prtDs3CurrentEntry 19 }

         -- The DS3 interface Interval

          -- The DS3 Interval Table contains various statistics
          -- collected by the Interface over the previous 24
          -- hours of operation.  The past 24 hours are broken into 96
          -- completed 15 minute intervals.

          prtDs3IntervalTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF PrtDs3IntervalEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "The DS3 Interval table."
              ::= { prtDs3PerfHistory 3 }

          prtDs3IntervalEntry OBJECT-TYPE
              SYNTAX  PrtDs3IntervalEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "An entry in the DS3 Interval table."
              INDEX   { ifIndex, prtDs3IntervalNumber }
              ::= { prtDs3IntervalTable 1 }

          PrtDs3IntervalEntry ::=
              SEQUENCE {
                  prtDs3IntervalNumber
                      Integer32,
                  prtDs3IntervalLOS
                      Gauge32,
                  prtDs3IntervalOOF
                      Gauge32,
                  prtDs3IntervalLOC
                      Gauge32,
                  prtDs3IntervalAIS
                      Gauge32,
                  prtDs3IntervalRDI
                      Gauge32,
                  prtDs3IntervalUAS
                      Gauge32,
	              prtDs3IntervalBIP
                      Gauge32,
                  prtDs3IntervalFEBE
                      Gauge32,
	              prtDs3IntervalSLM
                      Gauge32,
                  prtDs3IntervalSES 
                      Gauge32,
	              prtDs3IntervalES
                      Gauge32,
                  prtDs3IntervalBitParity
                      Gauge32,
                  prtDs3IntervalPlcpLOF
                      Gauge32,
                  prtDs3IntervalPlcpRAI
                      Gauge32,
	              prtDs3IntervalPlcpBIP
                      Gauge32,
                  prtDs3IntervalPlcpFEBE
	                  Gauge32,
				  prtDs3IntervalBPV
				       Gauge32,
				  prtDs3IntervalLCE
				       Gauge32,
				  prtDs3IntervalStatus 
	                  OCTET STRING
}

          prtDs3IntervalNumber OBJECT-TYPE
              SYNTAX  Integer32 (1..96)
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "A number between 1 and 96, where 1 is the most
                      recently completed 15 minute interval and 96 is
                      the least recently completed 15 minutes interval
                      (assuming that all 96 intervals are valid)."
              ::= { prtDs3IntervalEntry 1 }

          prtDs3IntervalLOS OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of LOS
                      seconds , encountered by a DS3 interface in
                      one of the previous 96, individual 15 minute,
                      intervals."
              ::= { prtDs3IntervalEntry 2 }

          prtDs3IntervalOOF OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of OOF
                      seconds, encountered by a DS3
                      interface in one of the previous 96, individual 15
                      minute, intervals."
              ::= { prtDs3IntervalEntry 3 }

          prtDs3IntervalLOC OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of LOC
                      seconds, encountered by a DS3
                      interface in one of the previous 96,
                      individual 15 minute, intervals."
              ::= { prtDs3IntervalEntry 4 }

          prtDs3IntervalAIS OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of AIS
                      seconds, encountered by a SONET
                      interface in one of the previous 96, individual 15
                      minute, intervals."
              ::= { prtDs3IntervalEntry 5 }

          prtDs3IntervalRDI OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of RDI
                      seconds, encountered by a DS3
                      interface in one of the previous 96, individual 15
                      minute, intervals."
              ::= { prtDs3IntervalEntry 6 }

          prtDs3IntervalUAS OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of UAS,
                      encountered by a DS3
                      interface in one of the previous 96, individual 15
                      minute, intervals."
              ::= { prtDs3IntervalEntry 7 }

          prtDs3IntervalBIP OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of 
                      BIP errors, encountered by a DS3 
                      interface in one of the previous 96, individual 15
                      minute, intervals."
              ::= { prtDs3IntervalEntry 8 }

          prtDs3IntervalFEBE OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of 
                      FEBE errors, encountered by a DS3
                      interface in one of the previous 96, individual 15
                      minute, intervals."
              ::= { prtDs3IntervalEntry 9 }

          prtDs3IntervalSLM OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of SLM
                      seconds, encountered by an E3
                      interface in one of the previous 96, individual 15
                      minute, intervals."
              ::= { prtDs3IntervalEntry 10 }

	 prtDs3IntervalSES OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of SES
                      encountered by a E3
                      interface in one of the previous 96, individual 15
                      minute, intervals."
	      ::= { prtDs3IntervalEntry 11 }

	 prtDs3IntervalES OBJECT-TYPE
	SYNTAX Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      " The number of Errored Seconds, encountered  by a
                      DS3 interface in one of the previous 96, individual 15
                      minute, intervals."
	::= { prtDs3IntervalEntry 12 }

prtDs3IntervalBitParity OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "Bit Parity Error counter. Relevant to T3 only."
              ::= { prtDs3IntervalEntry 13 }

        prtDs3IntervalPlcpLOF OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of LOF
                      seconds, encountered by a DS3
                      interface in one of the previous 96, individual 15
                      minute, intervals. This counter is relevant for plcpInternal(5)
                       or plcpExternal(6) configuration If frame types only."
              ::= { prtDs3IntervalEntry 14 }

prtDs3IntervalPlcpRAI OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                    "Receiving Yellow/Remote Alarm Indication. This counter is 
                      relevant for PLCP (external/internal) frame types only."
              ::= { prtDs3IntervalEntry 15 }

      prtDs3IntervalPlcpBIP OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                    " The counter associated with the number of BIP errors, 
                      encountered by a DS3 interface in the current 15 minute 
                      interval. This counter is relevant for PLCP (external/internal) 
                      frame types only."
              ::= { prtDs3IntervalEntry 16 }

      prtDs3IntervalPlcpFEBE OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                    " The counter associated with the number of FEBE
                      errors, encountered by a DS3 interface in the current
                      15 minute interval. This counter is relevant for PLCP
                      (external/internal) frame types only."
              ::= { prtDs3IntervalEntry 17 }

      prtDs3IntervalBPV OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                    " Number of BPVs (Bi-Polar Violations) , encountered by a 
                      DS3 interface in the specified 15 minute interval. 
                      This object is relevant only for Electrical Line
                      of Fomi-E3/T3."
              ::= { prtDs3IntervalEntry 18 }

      prtDs3IntervalLCE OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                    " Number of LCE (Link Code Errors) encountered 
                      by a DS3 interface in the specified 15 minute interval. 
                      This object is relevant only for Optical Links
                      of Fomi-E3/T3."
              ::= { prtDs3IntervalEntry 19 }


     prtDs3IntervalStatus OBJECT-TYPE
	          SYNTAX OCTET STRING  (SIZE (4))
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The statuses of the current interval:
                        0 - Valid.
                        1 - redundantLinkSwitch - the link has been switched 
                            by a redundancy mechanism.
                        2 - discontinuity - module was partialy out.
                        4 - notValid - module is out."
              ::= { prtDs3IntervalEntry 20 }

-- the DS3 Total table

prtDs3TotalTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF PrtDs3TotalEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
              " A list of Total entries."
              ::= { prtDs3PerfHistory 4 }

prtDs3TotalEntry OBJECT-TYPE
              SYNTAX  PrtDs3TotalEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
              "An entry of Total table."
              INDEX   { ifIndex }
              ::= { prtDs3TotalTable 1 }

PrtDs3TotalEntry     ::=
          SEQUENCE {
       	    prtDs3TotalUAS	Gauge32,
        	prtDs3TotalBPV	Gauge32,
            prtDs3TotalLCE  Gauge32
            }

prtDs3TotalUAS OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
              "Number of UASs (Unavailable Seconds) , encountered by a 
               DS3 interface in the previous 96 intervals.
               Invalid 15 minute intervals count as 0."
              ::= { prtDs3TotalEntry 6 }

prtDs3TotalBPV OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
              "Number of BPVs (Bi-Polar Violations) , encountered by a 
               DS3 interface in the previous 96 intervals.
               Invalid 15 minute intervals count as 0."
              ::= { prtDs3TotalEntry 17 }

prtDs3TotalLCE OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
              "Number of LCE (Link Code Errors) encountered 
               by a DS3 interface in the previous 96 intervals.
               Invalid 15 minute intervals count as 0."
              ::= { prtDs3TotalEntry 18 }
-- END
-- 
-- file :v:\doc\rdv\mib\ver495\brggen.txt
-- 
 --Version 4.95
--Initial Version:   4.0
--Date:   16.10.94              
--By:       Debby Koren &  Orly Nicklass
--File:       BRGgen.txt

--Last Updated by Ilana Schvetz 15-Jan-2003.


genBridge      OBJECT IDENTIFIER ::= {radBridges 1 }

-- At the end of the MIB there is a definition of all RAD general traps for bridges. 


radBridgeAction OBJECT-TYPE
    SYNTAX  INTEGER {
       reset(1),
       sendNetworkTab(2),
       deleteNetworkTab(3),
       sendRoutingTab(4),    -- Level II
       deleteRoutinTab(5),
       sendLanTab(6),
       deleteLanTab(7),
       deleteArpTab(8),
       sendArpTab(9),
       deleteRouteTab(10),   -- Level III
       sendRouteTab(11),
       deactivateAllMasks(12),
       saveAllActiveMasks(13),
       loadAndActivateAllMasksFromNVRAM(14),
       clearAllMasksFromNVRAM(15),
	   defaultConfig(16),
	   resetNVRAM(17),
	   clearIPNVRAM(18),
	noOp(255)
     }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"This variable enables the operator to perform one of the
	specified actions on the tables maintained by the network device.
	Send actions are not currently implemented.  Not all actions can 
	be performed on all bridges."
   ::= { genBridge 1  }

radBridgeInactiveArpTimeOut OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"This variable defines the maximum time period that can pass
	between ARP requests concerning an entry in the ARP table.
	After this time period, the entry is deleted from the table."
    ::= { genBridge 2  }


-- radBridgeMaskTab defines the format of  RAD Bridge OLD masking tables

radBridgeMaskTable    OBJECT-TYPE
    SYNTAX  SEQUENCE  OF RadBridgeMaskEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
	"Mask tables enable definition of forwarding restrictions and 
	control of message flow in the internetwork. Each entry
	in this table defines a mask statement consisting of up to 
	three mask definitions and an action defined by 
	radBridgeMaskOper. Different types of mask entries are supported, 
	as defined by radBridgeMaskType."
    ::=  { genBridge 3 }

radBridgeMaskEntry OBJECT-TYPE
    SYNTAX  RadBridgeMaskEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
    "An entry in table radBridgeMaskTable."
    INDEX   { radBridgeMaskType, radBridgeMaskIfIndex, radBridgeMaskNum  }
    ::=  { radBridgeMaskTable 1  }

RadBridgeMaskEntry ::= SEQUENCE {
    radBridgeMaskType
     INTEGER,
    radBridgeMaskIfIndex
     Integer32,   
    radBridgeMaskNum
     Integer32,
    radBridgeMaskDest
     INTEGER,
    radBridgeMaskPat1
     OCTET STRING,
    radBridgeMaskActiveBit1
     OCTET STRING,
    radBridgeMaskFrom1
     INTEGER,
    radBridgeMaskOffset1
     Integer32,
    radBridgeMaskCond1
     INTEGER,
    radBridgeMaskPat2
     OCTET STRING,
    radBridgeMaskActiveBit2
     OCTET STRING,
    radBridgeMaskFrom2
     INTEGER,
    radBridgeMaskOffset2
     Integer32,
    radBridgeMaskCond2
     INTEGER,
    radBridgeMaskPat3
     OCTET STRING,
    radBridgeMaskActiveBit3
     OCTET STRING,
    radBridgeMaskFrom3
     INTEGER,
    radBridgeMaskOffset3
     Integer32,
    radBridgeMaskCond3
     INTEGER,
    radBridgeMaskOper
     INTEGER
    }

radBridgeMaskType  OBJECT-TYPE
    SYNTAX INTEGER {
       tx(1),
       rx(2),
       compress(3),
       priority(4),
       loadSharing(5),
       facs(6),
       codConnect(7),
	   codDisconnect(8)
      }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"Defines the type of mask entry."
    ::= { radBridgeMaskEntry 1  }

radBridgeMaskIfIndex  OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION 
	"Specifies the if Index of the interface to which the mask is applied."
   ::= { radBridgeMaskEntry 2  }

radBridgeMaskNum  OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"The Mask entry number, defined by its line number in the mask
	table."
   ::= {  radBridgeMaskEntry 3  }

radBridgeMaskDest  OBJECT-TYPE
    SYNTAX INTEGER {
       unassigned-cond (1),
       broadcast-msge (2),
       multicast-msge (3),
       all-msge(4),
   none(5)
    }

    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION 
	"Specifies the type of destination address carried by the frame
	to which the mask will be applied. Unassigned-condition 
	deactivates the mask entry."
    ::= {  radBridgeMaskEntry 4   }


radBridgeMaskPat1 OBJECT-TYPE
    SYNTAX OCTET STRING  -- (SIZE (2))
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"Describes the mask field which is either a 16 bit binary pattern,
	or four digit hexadecimal pattern."
    ::= { radBridgeMaskEntry 5  }

radBridgeMaskActiveBit1  OBJECT-TYPE
    SYNTAX OCTET STRING  -- (SIZE (2))
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"Specifies the positions of the wild card characters (*) 
	in the radBridgeMaskPat1 field."
    ::= { radBridgeMaskEntry 6  }

radBridgeMaskFrom1  OBJECT-TYPE
    SYNTAX INTEGER {
       mac(1),
       llc(2),
	   net(3)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"Offset base of radBridgeMaskPat1 within the frame.
	 Net can be in some cases the data start point."
    ::= { radBridgeMaskEntry 7  }

radBridgeMaskOffset1  OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"Specifies the radBridgeMaskPat1 offset within the frame (in bytes) from 
	the base defined in by radBridgeMaskForm1.The mask offset is an even
	decimal number in the range of 0 to 1518." 
    ::= { radBridgeMaskEntry 8  }

radBridgeMaskCond1 OBJECT-TYPE
    SYNTAX INTEGER {
       false (1),
       true (2)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"Specifies the logical condition of the mask pattern:

	true  - Condition is valid if at the position specified by 
		radBridgeMaskOffset1 the packet contains data that matches
		the content of radBridgeMaskPat1.

	false - Condition is valid if at the position specified by 
		radBridgeMaskOffset1 the packet contains data that does not
		match the content of radBridgeMaskPat1."
    ::= {  radBridgeMaskEntry 9  }

radBridgeMaskPat2  OBJECT-TYPE
    SYNTAX OCTET STRING  --   (SIZE (2))
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"Describes the mask field which is either a 16 bit binary pattern,
	 or four digit hexadecimal pattern."
    ::= {  radBridgeMaskEntry 10  }

radBridgeMaskActiveBit2  OBJECT-TYPE
    SYNTAX OCTET STRING  --   (SIZE (2))
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"Specifies the positions of the wild card characters (*) 
	in the radBridgeMaskPat2 field."
    ::= {  radBridgeMaskEntry 11  }

radBridgeMaskFrom2  OBJECT-TYPE
    SYNTAX INTEGER { 
       mac (1),
       llc (2),
	   net(3)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"Offset base of radBridgeMaskPat2 within the frame.
	 Net can be in some cases the data start point."
    ::= {  radBridgeMaskEntry 12  }

radBridgeMaskOffset2  OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"Specifies the radBridgeMaskPat2 offset within the frame (in bytes) from 
	the base defined in by radBridgeMaskForm2.The mask offset is an even
	decimal number in the range of 0 to 1518." 
    ::= {  radBridgeMaskEntry 13  }

radBridgeMaskCond2 OBJECT-TYPE
    SYNTAX INTEGER { 
       false (1),
       true (2)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"Specifies the logical condition of the mask pattern:

	true  - Condition is valid if at the position specified by 
		radBridgeMaskOffset2 the packet contains data that matches
		the content of radBridgeMaskPat2.

	false - Condition is valid if at the position specified by 
		radBridgeMaskOffset2 the packet contains data that does not
		match the content of radBridgeMaskPat2."
    ::= {  radBridgeMaskEntry 14  }

radBridgeMaskPat3 OBJECT-TYPE
    SYNTAX OCTET STRING  --   (SIZE (2))
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"Describes the mask field which is either a 16 bit binary pattern,
	or four digit hexadecimal pattern."
    ::= {  radBridgeMaskEntry 15  }

radBridgeMaskActiveBit3 OBJECT-TYPE
    SYNTAX OCTET STRING  --   (SIZE (2))
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"Specifies the positions of the wild card characters (*) 
	in the radBridgeMaskPat3 field."
    ::= {  radBridgeMaskEntry 16  }

radBridgeMaskFrom3 OBJECT-TYPE
    SYNTAX INTEGER { 
       mac (1),
       llc (2),
	   net (3)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"Offset base of radBridgeMaskPat3 within the frame.
	 Net can be in some cases the data start point."
    ::= {  radBridgeMaskEntry 17  }

radBridgeMaskOffset3 OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"Specifies the radBridgeMaskPat3 offset within the frame (in bytes) from 
	the base defined in by radBridgeMaskForm3. The mask offset is an even
	decimal number in the range of 0 to 1518." 
    ::= {  radBridgeMaskEntry 18  }

radBridgeMaskCond3 OBJECT-TYPE
   SYNTAX INTEGER { 
       false (1),
       true (2)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"Specifies the logical condition of the mask pattern:

	true  - Condition is valid if at the position specified by 
		radBridgeMaskOffset3 the packet contains data that matches
		the content of radBridgeMaskPat3

	false - Condition is valid if at the position specified by 
		radBridgeMaskOffset3 the packet contains data that does not
		match the content of radBridgeMaskPat3."
    ::= {  radBridgeMaskEntry 19  }

radBridgeMaskOper OBJECT-TYPE
    SYNTAX INTEGER { 
       block (1),
       forward (2),
       route (3),
       forward-route (4),
       high-priority (5),
       noOp(6),
       delete(7)
     }
   
   
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
	"The type of action to be taken if the frame meets the 
     conditions of the mask.
     noOp = disabled (mask remains on list, but is not active) 
	 delete = mask is removed from the list. "
    ::= {  radBridgeMaskEntry 20 }

radBridgeCOD      OBJECT IDENTIFIER ::= {genBridge 4 }

radBridgeCODParamTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF RadBridgeCODEntry
	MAX-ACCESS  not-accessible
	STATUS  current
	DESCRIPTION
	       "The table of COD parameters "
	::= { radBridgeCOD 1}


radBridgeCODEntry OBJECT-TYPE
	SYNTAX RadBridgeCODEntry
	MAX-ACCESS  not-accessible
	STATUS  current
	DESCRIPTION
	       "Each radBridgeCODEntry consists of the following parameters"
	INDEX   {radBridgeCODIfIndex}
	::= { radBridgeCODParamTable 1 }


RadBridgeCODEntry ::= SEQUENCE {
	  radBridgeCODIfIndex
		Integer32,
	  radBridgeCODManualConnect
		INTEGER,
	  radBridgeCODMode
		INTEGER,
	  radBridgeCODConnectDelay
		Integer32,
	  radBridgeCODisConnectDelay
		Integer32,
	  radBridgeCODImplicitSwitch
		INTEGER,
	  radBridgeCODNumAccess
		Counter32,
	  radBridgeCODTotalConnecTime
		Integer32
 }

radBridgeCODIfIndex OBJECT-TYPE
	SYNTAX  Integer32 
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION
	       "The interface to which this COD entry is applicable."
	::= { radBridgeCODEntry 1 }

radBridgeCODManualConnect OBJECT-TYPE
	SYNTAX  INTEGER {
		connect(1),
		disconnect(2)
	     }
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
	       "The management station can start connection manually
		by setting this parameter"
	::= { radBridgeCODEntry 2 }


radBridgeCODMode OBJECT-TYPE
	SYNTAX  INTEGER {
		answer(1),
		originate(2),
		disable(3),
	    answerAndOriginate(4)
	     }
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
	     "In answer mode only one incoming call may be accepted at a time. Other nodes
	      attempting to access the local modem will receive a busy signal until the
	      connection is terminated. (Answer mode has no difficulty supporting multiple
	      remote connections to one local port, as blocking multiple incoming calls is
	      just a modem function. Originate mode, on the other
	      hand will only support a single local port to remote port connection).
	      The disable parameter disables the COD utility for this interface. 
	      Choosing any other mode will enable the COD utility."
	::= { radBridgeCODEntry 3 }

radBridgeCODConnectDelay OBJECT-TYPE
	SYNTAX  Integer32
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
     "The connect delay defines the minimum time period that 
      the link must stay disconnected, between 2 succesive 
      connections (in seconds)."
	::= { radBridgeCODEntry 4 }

radBridgeCODisConnectDelay OBJECT-TYPE
	SYNTAX  Integer32
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
		"The disconnect delay defines the minimum time period
		 the link must stay connected, between 2 succesive
		 disconnections (in seconds)."
	::= { radBridgeCODEntry 5 }


radBridgeCODImplicitSwitch  OBJECT-TYPE
	SYNTAX  INTEGER  {
	      enable(1),
	      disable(2)
	}
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
	     "The inplicit switch allows the user to ignore implicit triggers  provided 
	      by the COD software."
--      DEFVAL  { 1 }
	::= { radBridgeCODEntry 6 }


radBridgeCODNumAccess  OBJECT-TYPE
	SYNTAX Counter32
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
	     "The number of successful connections that have been established since 
	      the COD has been reset."
	::= { radBridgeCODEntry 7}

radBridgeCODTotalConnecTime  OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
	     "The sum of all the connect time intervals since the COD was reset."
	::= { radBridgeCODEntry 8}




 
radBridgeCODTimeTriggerTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF RadBridgeCODTimeTriggerEntry
	MAX-ACCESS  not-accessible
	STATUS  current
	DESCRIPTION
		     "The table of COD parameters "
	::= { radBridgeCOD 2 }

radBridgeCODTimeTriggerEntry  OBJECT-TYPE
	SYNTAX RadBridgeCODTimeTriggerEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
	      "Each radBridgeCODTimeTriggerEntry consists of the following parameters"
	INDEX   { radBridgeCODTimeIfIndex, radBridgeCODDay, radBridgeCODTimeTriggerNum }
	::= { radBridgeCODTimeTriggerTable 1 }

RadBridgeCODTimeTriggerEntry ::= SEQUENCE {
	radBridgeCODTimeIfIndex
	      Integer32,
	radBridgeCODDay
	      INTEGER,
	radBridgeCODTimeTriggerNum
	      Integer32,
	radBridgeCODTimeTriggerFrom
	      DisplayString,
	radBridgeCODTimeTriggerTo
	      DisplayString,
	radBridgeCODTimeTriggerStatus
	      INTEGER
	}

radBridgeCODTimeIfIndex OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
	       "The interface to which this COD  Time Trigger  entry is applicable."
	    ::= { radBridgeCODTimeTriggerEntry 1}

radBridgeCODDay  OBJECT-TYPE
    SYNTAX  INTEGER {
	  mon(1),
	  tue(2),
	  wed(3),
	  thu(4),
	  fri(5),
	  sat(6),
	  sun(7)
	 }
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
       " The  day of the week in which  the dial up connection operates."
    ::= { radBridgeCODTimeTriggerEntry 2 }

radBridgeCODTimeTriggerNum  OBJECT-TYPE
    SYNTAX  Integer32  (1..3)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
       " Every day of the week the user can configure 3 dial up connections."
   ::= { radBridgeCODTimeTriggerEntry 3 }

radBridgeCODTimeTriggerFrom  OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
       "Time to start Dial Up connection, in format hh:mm."
    ::= {radBridgeCODTimeTriggerEntry 4 }

radBridgeCODTimeTriggerTo  OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
       "Time to terminate Dial Up connection, in format HH:MM."
 ::= {radBridgeCODTimeTriggerEntry 5 }

radBridgeCODTimeTriggerStatus OBJECT-TYPE
	     SYNTAX  INTEGER {
		  valid(1),
		  invalid(2)           
	    }
	     MAX-ACCESS  read-write
	     STATUS  current
	     DESCRIPTION
	       "The status of a table entry."
   ::= { radBridgeCODTimeTriggerEntry  6 }

radBridgeCODTraffic  OBJECT IDENTIFIER ::= { radBridgeCOD 3}

radBridgeCODTrafficTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF RadBridgeCODTrafficEntry
	MAX-ACCESS  not-accessible
	STATUS  current
	DESCRIPTION
	       "The table of COD Traffic trigger "
	::= { radBridgeCODTraffic 1 }

radBridgeCODTrafficEntry OBJECT-TYPE
	SYNTAX RadBridgeCODTrafficEntry
	MAX-ACCESS  not-accessible
	STATUS  current
	DESCRIPTION
	       "Each radBridgeCODTrafficEntry consists of the following parameters."
	INDEX {radBridgeCODProtocolType}
	::= { radBridgeCODTrafficTable 1}


RadBridgeCODTrafficEntry ::= SEQUENCE {
	  radBridgeCODProtocolType
		INTEGER,
	  radBridgeCODTrafficTriggerStatus
		INTEGER }


radBridgeCODProtocolType OBJECT-TYPE
	SYNTAX INTEGER {
		ip(1),
		ipx(2),
		other(3)
}                                   
 
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
		"The Protocol Type of the Traffic Table"
	::= { radBridgeCODTrafficEntry 1 }


radBridgeCODTrafficTriggerStatus OBJECT-TYPE
	SYNTAX INTEGER {
		enable(1),
		disable(2) 
}
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
		"Command of Status of the Protocol Traffic Trigger"
	::= { radBridgeCODTrafficEntry 2 }


radBridgeCODRemoteIPAddr  OBJECT-TYPE
	SYNTAX IpAddress
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
		" This is the Remote IP Address"
	::= { radBridgeCODTraffic 2 }


radBridgeCODIPMask  OBJECT-TYPE
	SYNTAX IpAddress
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
		" This is the Mask of the Remote IP Address"
	::= { radBridgeCODTraffic 3 }

radBridgeCODTrafficTriggerProtType OBJECT-TYPE
	SYNTAX  OCTET STRING
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
		"Protocol Type for the User Defined Protocol Traffic Trigger (3)."
	::= { radBridgeCODTraffic 4 }


--COD Condition table

radBridgeCODCondTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF RadBridgeCODCondEntry
	MAX-ACCESS  not-accessible
	STATUS  current
	DESCRIPTION
	       "The table of COD Condition parameters "
	::= { radBridgeCOD 4}


radBridgeCODCondEntry OBJECT-TYPE
	SYNTAX RadBridgeCODCondEntry
	MAX-ACCESS  not-accessible
	STATUS  current
	DESCRIPTION
	       "Each radBridgeCODCondEntry consists of the following parameters"
	INDEX   {radBridgeCODCondIfIndex}
	::= { radBridgeCODCondTable 1 }


RadBridgeCODCondEntry ::= SEQUENCE {
	  radBridgeCODCondIfIndex 
	  	Integer32, 
	  radBridgeCODOriginateConnectCondition 
	  	INTEGER, 
	  radBridgeCODOriginateDisConnectCondition
	  	INTEGER,
	  radBridgeCODOriginateDisConnectDelay
	  	Integer32, 
	  radBridgeCODAnswerConnectCondition
	  	INTEGER, 
      radBridgeCODSpecificOnTrafficOIDCondition
        OBJECT IDENTIFIER, 
      radBridgeCODDisConnectMinimunFramesNumber
        Integer32 



  }


radBridgeCODCondIfIndex OBJECT-TYPE
	SYNTAX  Integer32 
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION
	"The interface, this COD entry is applicable to."
	::= { radBridgeCODCondEntry 1 }
   
radBridgeCODOriginateConnectCondition OBJECT-TYPE
	SYNTAX  INTEGER {
               onPowerOn           (1),
               whenAnyStationOnLan (2),
               onTraffic           (3),
               onManualConnect     (4)
               }
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
	     " This condition, allows the user to specify the 
	       condition under which the link is connected.
           The options are
                  onPowerOn           - On power on.
                  whenAnyStationOnLan - When any station on lan.
                  onTraffic           - On traffic. The user can specify the 
                                        condition/s for connection.
                                        The connection will be defined in
                                        CODSpecificOnTrafficConditionOID .
                  onManualConnect     - depends on radBridgeCODManualConnect 
                                        OBJECT-TYPE (=connect).
                  "
	::= { radBridgeCODCondEntry 2 }
   
radBridgeCODOriginateDisConnectCondition OBJECT-TYPE
	SYNTAX  INTEGER {
               noStationOnLan                 (1),
               onTraffic                      (2),
               onDelayFromConnectionOnRequest (3),
               onManualDisConnect             (4)
               }
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
	     "This condition allows the user to specify the 
	      condition under which the link is disconnected.
          The options are: 
                  noStationOnLan - When there is no station on lan.
                                   Counts 15 minutes from the point the last 
                                   frame from lan has been received. If no 
                                   frame have been transmitted on lan by the 
                                   end of this period, disconnect the connection.
                  onTraffic      - On traffic. The user can specify the 
                                   condition/s for disconnection.
                                   The disconnection will be defined in
                                   CODSpecificOnTrafficConditionOID .
                  onDelayFromConnectionOnRequest - 
                                   On Delay From Connection On Request .
                                   The delay time period will be defined in
                                   CODOriginateDisConnectDelay . 
                  onManualDisConnect - depends on radBridgeCODManualConnect 
                                    OBJECT-TYPE (=disconnect).
                  "
	::= { radBridgeCODCondEntry 3 }

radBridgeCODOriginateDisConnectDelay OBJECT-TYPE
	SYNTAX  Integer32 
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
             "Delay time in seconds. "
	::= { radBridgeCODCondEntry 4 }

radBridgeCODAnswerConnectCondition OBJECT-TYPE
	SYNTAX  INTEGER {
               onPowerOn           (1),
               whenAnyStationOnLan (2),
               onTraffic           (3),
               onManualConnect     (4)
               }
	MAX-ACCESS  read-write
	STATUS  current
	DESCRIPTION
	     "CODCondAnswerConnect allows the user to specify 
	      the condition under which the link is connected.
          The options are: 
                  onPowerOn           - On power on.
                  whenAnyStationOnLan - When any station on lan.
                  onTraffic           - On traffic. The user can specify the 
                                        condition/s for connection.
                                        The connection will be defined in
                                        CODSpecificOnTrafficConditionOID .
                  onManualConnect     - depends on radBridgeCODManualConnect 
                                        OBJECT-TYPE .
             "     
	::= { radBridgeCODCondEntry 5 }


radBridgeCODSpecificOnTrafficOIDCondition OBJECT-TYPE
        SYNTAX  OBJECT IDENTIFIER
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
             "A reference to a specific entry in the
			  radBridgeMaskTable, which describes the 
              particular COD condition .
              If Connect or Disconnect Conditions are not 
              onTraffic, its value should be set to the 
              OBJECT IDENTIFIER { 0 0 }. "
	::= { radBridgeCODCondEntry 6 }


radBridgeCODDisConnectMinimunFramesNumber OBJECT-TYPE
        SYNTAX Integer32
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
             "Frames rate."
	::= { radBridgeCODCondEntry 7 }

--The IPX following objects define the Spoofing 

radBridgeIPX      OBJECT IDENTIFIER ::= {genBridge 5 }


radBridgeIPXdriver      OBJECT IDENTIFIER ::=  {radBridgeIPX 1 }
radBridgeIPXRip          OBJECT IDENTIFIER ::=  {radBridgeIPX 2 }
radBridgeIPXSap         OBJECT IDENTIFIER ::=  {radBridgeIPX 3 }

radBridgeIPXForwarding OBJECT-TYPE
    SYNTAX  INTEGER {
	forwarding(1),
       not-forwarding(2)
       }
    MAX-ACCESS  read-write      
    STATUS  current
    DESCRIPTION
       "The indication of whether this entity is acting as an IPX
       gateway in respect to the forwarding of datagrams received by,
       but not addressed to, this entity.  IPX gateways forward
       datagrams.  IPX hosts do not.  Note that changing this parameter 
       requiers RESET of the router."
--      DEFVAL  { 1 }
    ::= { radBridgeIPXdriver 1 }

radBridgeIPXRipOutPackets OBJECT-TYPE
    SYNTAX  Counter32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "The total number of packets transmitted by RIP."
    ::= { radBridgeIPXRip 1 }
    
radBridgeIPXRipInPackets OBJECT-TYPE
    SYNTAX  Counter32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "The total number of packets received by RIP.  This will include
       any packets that are subsequently discarded."
    ::= { radBridgeIPXRip 2 }
    
radBridgeIPXRipInDiscards OBJECT-TYPE
    SYNTAX  Counter32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "The number of received packets discarded by RIP."
    ::= { radBridgeIPXRip 3 }
    
radBridgeIPXRipTblNoOfEntries OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "The max number of entries that exist in the RIP routing table."
    ::= { radBridgeIPXRip 4 }
    
radBridgeIPXRipTblBcastTrigUpdateInterval OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
       "The default time interval (in seconds)between triggered RIP updates on 
       a broadcast type interface.  A triggered update occurs when a change is 
       detected in the routing database.  This time interval delays the 
       broadcasting of these updates so that changes on the network will 
       not result in a lot of triggered updates."
    ::= { radBridgeIPXRip 5 }
  

 
radBridgeIPXRipTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF RadBridgeIPXRipTableEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "The routing table used by RIP to calculate routes to remote
       desination networks."
    ::= { radBridgeIPXRip 6 }
    
radBridgeIPXRipTableEntry OBJECT-TYPE
    SYNTAX  RadBridgeIPXRipTableEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "The routing information for one of this entity's destination networks."
    INDEX   { radBridgeIPXRipDestNetwork, 
	      radBridgeIPXRipPolicy }
    ::= { radBridgeIPXRipTable 1 }
    
RadBridgeIPXRipTableEntry ::= SEQUENCE {
radBridgeIPXRipDestNetwork
     OCTET STRING (SIZE(4)),
radBridgeIPXRipPolicy
     INTEGER,
radBridgeIPXRipForwardingRouter
     OCTET STRING (SIZE(6)),
radBridgeIPXRipNIC
     Integer32,
radBridgeIPXRipTickMetric
     Integer32,
radBridgeIPXRipHopMetric
     Integer32,
radBridgeIPXRipAgingTime
     TimeTicks,
radBridgeIPXRipValueStatus
     INTEGER,
radBridgeIPXRipForwardType
     INTEGER
}

radBridgeIPXRipDestNetwork OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(4))
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
	 "The destination network address to which this entry's
	  routing information pertains."
    ::= {radBridgeIPXRipTableEntry 1 }
    
radBridgeIPXRipPolicy OBJECT-TYPE
    SYNTAX  INTEGER  {
	main(1),
	alternate(2)
    }
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "A value specifying the precidence of the route.  A value of
       zero means that the route is the best route, a value of one
       means that the route is the second best route and so on."
    ::= { radBridgeIPXRipTableEntry 2 }
    
radBridgeIPXRipForwardingRouter OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(6))
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
       "The IPX node address of the next hop (router) for the
       entry's associated destination network."
    ::= { radBridgeIPXRipTableEntry 3 }
    
radBridgeIPXRipNIC OBJECT-TYPE
    SYNTAX  Integer32 
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
       "An interface identifier specifying what IPX interface the
       next hop can be found on."
    ::= { radBridgeIPXRipTableEntry 4 }
    
radBridgeIPXRipTickMetric OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
       "The metric, in terms of transit time, associated with the route
       given by the entry.  This time is in terms of 1/18ths of a
       second."
    ::= { radBridgeIPXRipTableEntry 5 }
    
radBridgeIPXRipHopMetric OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
       "The metric, in terms of distance , associated with the route
	given by the entry."
    ::= { radBridgeIPXRipTableEntry 6 }
    
    
radBridgeIPXRipAgingTime OBJECT-TYPE
    SYNTAX  TimeTicks
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
      "The last time that the entry was updated.  The time will be
       provided in terms of the MIB-I object sysUpTime."
    ::= {radBridgeIPXRipTableEntry 7 }
    
radBridgeIPXRipValueStatus OBJECT-TYPE
    SYNTAX  INTEGER {
	static(1),
	dynamic(2),
	invalid(3),
	semiDynamic(4)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
       "The entry status value; whether the entry is permanent (added
	statically), reachable or unreachable.  In the latter two cases
       it would be added by RIP. A semiDynamic entry is an entry
       enterd manualy by the user and can be updated by the router."
    ::= { radBridgeIPXRipTableEntry 8 }
    
radBridgeIPXRipForwardType  OBJECT-TYPE
    SYNTAX  INTEGER {
	 other    (1), -- not specified by this MIB
	 local    (2), -- local interface
	 remote   (3)  -- remote destination
     }
     MAX-ACCESS   read-write
     STATUS   current
     DESCRIPTION
	"The type of route. Note that local(2) refers to a route for which the 
	 next hop is the final destination; remote(3) refers to  a  route  
	 for which  the next  hop is not the final destination."
    ::= {radBridgeIPXRipTableEntry 9 }
    
	  
    
radBridgeIPXRipInfTable OBJECT-TYPE
     SYNTAX  SEQUENCE OF RadBridgeIPXRipInfEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
     "The RIP interface table."
     ::= { radBridgeIPXRip 7 }
    
radBridgeIPXRipInfEntry OBJECT-TYPE
     SYNTAX  RadBridgeIPXRipInfEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
	  "Each entry corresponds to one ifindex."
     INDEX   { radBridgeIPXRipInfIfIndex}
     ::= { radBridgeIPXRipInfTable 1 }
    
RadBridgeIPXRipInfEntry ::= SEQUENCE {
     radBridgeIPXRipInfIfIndex
     Integer32,
     radBridgeIPXRipInfBcastUpdate
     Integer32,
     radBridgeIPXRipInfAgeMultiplier
     Integer32
     }
    
radBridgeIPXRipInfIfIndex OBJECT-TYPE
     SYNTAX  Integer32
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
	  "This value of Ifindex is same as radBridgeIPXIfIndex in the
	   IPX Interface Table."
     ::= { radBridgeIPXRipInfEntry 1 }
    
radBridgeIPXRipInfBcastUpdate OBJECT-TYPE
     SYNTAX  Integer32
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
	    "The RIP periodic update interval, in seconds. Zero value
	     corresponds to infinite interval."
--     DEFVAL {60}
     ::= { radBridgeIPXRipInfEntry 2 }
    
radBridgeIPXRipInfAgeMultiplier OBJECT-TYPE
     SYNTAX  Integer32
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
       "The holding multiplier for information received in RIP
       periodic updates. Zero value corresponds to infinite aging time."
--     DEFVAL {3}
     ::= { radBridgeIPXRipInfEntry 3 }

radBridgeIPXSapOutPackets OBJECT-TYPE
    SYNTAX  Counter32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
	   "The total number of packets transmitted by SAP."
    ::= { radBridgeIPXSap 1 }
    
radBridgeIPXSapInPackets OBJECT-TYPE
    SYNTAX  Counter32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
      "The total number of packets received by SAP.  This will include
       any packets that are subsequently discarded."
    ::= { radBridgeIPXSap 2 }
    
radBridgeIPXSapInDiscards OBJECT-TYPE
    SYNTAX  Counter32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
	   "The number of received packets discarded by SAP."
    ::= { radBridgeIPXSap 3 }
    
    
radBridgeIPXSapTblNoOfEntries OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
	   "The max number of entries that exist in the SAP Server
    Information table."
    ::= { radBridgeIPXSap 4 }
    
radBridgeIPXSapTblBcastTrigUpdateInterval OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
       "The default time interval (in seconds) between triggered SAP updates on a
	broadcast style interface.  A triggered update occurs when a
	change is detected in the service database.  This time interval
	delays the transmission of these updates so that changes on the
	network will not result in a lot of triggered updates."
    ::= { radBridgeIPXSap 5 }
        
    
   
radBridgeIPXSapTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF RadBridgeIPXSapTableEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
	   "The Server Information table is used by SAP to store information
	   of services which are available on the internetwork."
    ::= { radBridgeIPXSap 6 }
    
radBridgeIPXSapTableEntry OBJECT-TYPE
    SYNTAX  RadBridgeIPXSapTableEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "The server information for one of this entity's server entries."
    INDEX   { radBridgeIPXSapServerType,
	  radBridgeIPXSapName }
    ::= { radBridgeIPXSapTable 1 }

RadBridgeIPXSapTableEntry ::= SEQUENCE {
    radBridgeIPXSapServerType
	Integer32,
    radBridgeIPXSapName
	DisplayString (SIZE(48)),
    radBridgeIPXSapNetwork
	OCTET STRING (SIZE(4)),
    radBridgeIPXSapNode
	OCTET STRING (SIZE(6)),
    radBridgeIPXSapSocket
	Integer32,
    radBridgeIPXSapHopsToServer
	Integer32,
    radBridgeIPXSapNIC
	Integer32,
    radBridgeIPXSapAgingTime
	TimeTicks,
   radBridgeIPXSapStatus
	INTEGER 
    }
    
radBridgeIPXSapServerType OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
	   "The type of the server for which this entry pertains."
    ::= { radBridgeIPXSapTableEntry 1 }
    
radBridgeIPXSapName OBJECT-TYPE
    SYNTAX  DisplayString (SIZE(48))
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
	   "The name of the server for which this entry pertains."
    ::= { radBridgeIPXSapTableEntry 2 }
    
radBridgeIPXSapNetwork OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(4))
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	   "The IPX network address of the host on which this server exists."
    ::= { radBridgeIPXSapTableEntry 3 }
    
radBridgeIPXSapNode OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(6))
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	   "The IPX node address of the host on which this server exists."
    ::= { radBridgeIPXSapTableEntry 4 }
    
radBridgeIPXSapSocket OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	   "The IPX socket number that is being used by the server to
	   which this entry pertains."
    ::= { radBridgeIPXSapTableEntry 5 }
    
radBridgeIPXSapHopsToServer OBJECT-TYPE
    SYNTAX  Integer32 (1..16)
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
       "The number of hops to the entity on which this server exists."
    ::= { radBridgeIPXSapTableEntry 6 }
    
radBridgeIPXSapNIC OBJECT-TYPE
    SYNTAX  Integer32 
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
       "An Network Interface Card identifier specifying what IPX 
	interface the next hop can be found on."
    ::= { radBridgeIPXSapTableEntry 7 }
    
radBridgeIPXSapAgingTime OBJECT-TYPE
    SYNTAX  TimeTicks
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "The last time that the entry was updated.  The time will be
	provided in terms of the MIB-I object sysUpTime."
    ::= { radBridgeIPXSapTableEntry 8 }
    
radBridgeIPXSapStatus OBJECT-TYPE
    SYNTAX  INTEGER {
    permanent(1),
    dynamic(2),
    invalid(3),
    semiDynamic(4)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
       "The status of the entry."
    ::= { radBridgeIPXSapTableEntry 9 }
   
  

radBridgeIPXSapInfTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF RadBridgeIPXSapInfEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
    "The Sap interface table."
    ::= { radBridgeIPXSap 7 }
    
radBridgeIPXSapInfEntry OBJECT-TYPE
    SYNTAX  RadBridgeIPXSapInfEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
	 "Each entry corresponds to one ifindex."
    INDEX   {radBridgeIPXSapInfIfIndex}
    ::= { radBridgeIPXSapInfTable 1 }
    
RadBridgeIPXSapInfEntry ::= SEQUENCE {
    radBridgeIPXSapInfIfIndex
    Integer32,
    radBridgeIPXSapInfBcastUpdate
    Integer32,
    radBridgeIPXSapInfAgeMultiplier
    Integer32
    }
    
radBridgeIPXSapInfIfIndex OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
	 "This value of Ifindex is same as radBridgeIPXIfIndex in the
	  IPX Interface Table."
    ::= { radBridgeIPXSapInfEntry 1 }
    
radBridgeIPXSapInfBcastUpdate OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
       "The SAP periodic update interval, in seconds. Zero value
       corresponds to infinite interval."
--    DEFVAL {60}
    ::= { radBridgeIPXSapInfEntry 2 }
    
radBridgeIPXSapInfAgeMultiplier OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
       "The holding multiplier for information received in SAP
       periodic updates. Zero value corresponds to infinite aging time."
--    DEFVAL {3}
    ::= { radBridgeIPXSapInfEntry 3 }


-- radMaskingTab defines the new format of RAD Bridge masking tables


GenAddress ::= OCTET STRING (SIZE(12))

newMasking     OBJECT IDENTIFIER ::= {genBridge 6 }

maskingMaxEntries OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
        "The maximum number of entries in the masking table."
    ::=  { newMasking 1 }


maskingCurrentEntries OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
        "The number of entries in the mask table."
    ::=  { newMasking 2 }

maskingTable    OBJECT-TYPE
    SYNTAX  SEQUENCE  OF MaskingEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
	    "This is the new masking scheme. 
	    Mask tables enable definition of forwarding restrictions and 
	    control of message flow in the internetwork. Each entry
	    in this table defines a mask statement and an action defined by 
	    maskingOperation."
    ::=  { newMasking 3 }
    
maskingEntry OBJECT-TYPE
    SYNTAX  MaskingEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
	    "Defines the contents of each line in the mask table."
    INDEX  { maskingType, maskingIfIndex, maskingIndex }
    ::=  { maskingTable 1 }

MaskingEntry ::= SEQUENCE {
                     maskingType
					  INTEGER,
                     maskingIfIndex
                      Integer32,
                     maskingIndex
                      Integer32,
                     maskingProtocolType
                      INTEGER,
					 maskingSmartMaskOID
					  OBJECT IDENTIFIER,
                     maskingFrameType
                      INTEGER,
                     maskingFrameTypeCondition
                      INTEGER,
                     maskingSourceAddress
                      GenAddress,
                     maskingSourceActiveBits
                      GenAddress,
                     maskingSourceMacOrNet
                        INTEGER,
                     maskingSourceCondition
                      INTEGER,
                     maskingDestAddress
                      GenAddress,
                     maskingDestActiveBits
                      GenAddress,
                     maskingDestMacOrNet
                        INTEGER,
                     maskingDestCondition
                      INTEGER,
                     maskingLowLevelProt
                      INTEGER,
                     maskingLowLevelProtCondition
                      INTEGER,
                     maskingHighLevelProt
                      Integer32,
                     maskingHighLevelProtCondition
                      INTEGER,
                     maskingPortNum
                      Integer32,
                     maskingPortNumCondition
                      INTEGER,
                     maskingOperation
                      INTEGER,
                     maskingSrcPortNum 
                      Integer32,
                     maskingSrcPortNumCondition 
                      INTEGER
                       }

   maskingType OBJECT-TYPE
    SYNTAX  INTEGER {
	  tx            (1),
	  rx            (2),
      compress(3),
      priority(4),
      loadSharing(5),
      facs(6),
      codConnect(7),
      codDisconnect(8)
     }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
        "Defines the type of mask entry. "
    ::= {    maskingEntry 1  }


   maskingIfIndex  OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION 
	"Specifies the ifIndex of the interface to which the mask is applied."
	::= {    maskingEntry 2  }
   

                  
   maskingIndex OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
        "An index to the masking table. This number should not be greater than maskingMaxEntries"
    ::= {    maskingEntry 3  }
                  
            
                
        
   maskingProtocolType OBJECT-TYPE
    SYNTAX  INTEGER {
    unknown     (1),
    ip          (2),
	ipx         (3),
	sna         (4),
	netbios     (5),
              apple      (6),
              dec         (7),
    all         (255)
    }			
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
         "The base protocol for masking. IPX, IP, others."
    ::= {    maskingEntry 4  }


    maskingSmartMaskOID OBJECT-TYPE
	 SYNTAX  OBJECT IDENTIFIER
	 MAX-ACCESS  read-only
	 STATUS  current
	 DESCRIPTION
	      "A reference to a specific Smart mask table (old radBridgeMaskTable)
	       which enables a more specific mask type.
		   If this information is not available, its value 
		   should be set to the OBJECT IDENTIFIER { 0 0 }. "
     ::= {  maskingEntry 5  }		    

         
    maskingFrameType OBJECT-TYPE
    SYNTAX  INTEGER {
    unknown     (1),
    all         (2),
    broadcast   (3),
    multicast   (4)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
        "Enables the user to decide about frame type 
          * all frame 
          * just broadcast 
          * just multicast."
    ::= {    maskingEntry 6  }

   maskingFrameTypeCondition OBJECT-TYPE
    SYNTAX  INTEGER {
    false      (1),
    true       (2)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"Specifies the logical condition of the mask pattern:

	true  - Condition is valid if at the position specified by 
   		   maskingFrameType the packet contains data that matches
  	the content of maskingFrameType.

	fa    lse - Condition is valid if at the position specified by 
		   maskingFrameType the packet contains data that does not
    		match the content of maskingFrameType."
    ::= {    maskingEntry 7  }

   maskingSourceAddress OBJECT-TYPE
    SYNTAX  GenAddress
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
       "The source address is according to the maskingMacOrNet and 
        maskingProtocolType variables. 
        In case of 'MAC' enter 6 bytes (48 bit) of source address.
        In case of 'NET' 
            if the    maskingProtocolType is IP, this is the IP address
            if the    maskingProtocolType is IPX, this is the IPX address 
                 (nnnnmmmmmmss)
                                nnnn   - IPX net address
                                mmmmmm - Node address (Mac)
                                ss     - IPX socket
        In case of 'Apple' 
                                nn - net address (4 nibbles) 
                                ss - socket (4 nibbles)."   
    ::= {    maskingEntry 8  }

   maskingSourceActiveBits OBJECT-TYPE
    SYNTAX  GenAddress
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	   "Specifies the positions of the wild card characters (*) 
	    in the    maskingSourceAddress field. Only the 1's bit will be taken in 
        considerations."
    ::= {    maskingEntry 9  }

   maskingSourceMacOrNet OBJECT-TYPE
    SYNTAX  INTEGER {
    macAddress  (1),
    netAddress  (2),
    ipRange     (3),
    appleAddress(4)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"The variable maskingSourceAddress and maskingSourceActiveBits 
	 will be treated as MAC, or NET address.
	 -  If maskingProtocolType = 'all', 'sna', 'netbios', dec or 
		'unknown', the maskingSourceMacOrNet can be macAddress only!
	 -  If maskingProtocolType = 'ip' the 
		maskingSourceMacOrNet can be  macAddress or netAddress or 
		appleAddress. 
	 -  If maskingProtocolType = 'ipx', the 
		maskingSourceMacOrNet can be either macAddress or netAddress. 
	 -  If maskingProtocolType = 'apple', the 
		maskingSourceMacOrNet can be either macAddress or appleAddress." 
    ::= {    maskingEntry 10  }
    
   maskingSourceCondition OBJECT-TYPE
    SYNTAX  INTEGER {
    false (1),
    true (2)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"Specifies the logical condition of the mask pattern:

	true  - Condition is valid if at the position specified by 
	           maskingSourceAddress (in conjunction with maskingSourceActiveBits) 
	        the packet contains data that matches the content of maskingSourceAddress.

	false - Condition is valid if at the position specified by 
		   maskingSourceAddress (in conjunction with maskingSourceActiveBits) 
	    	the packet contains data that does not match the content of
	        maskingSourceAddress."
    ::= {    maskingEntry 11 }
    
   maskingDestAddress OBJECT-TYPE
    SYNTAX  GenAddress
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
       "If maskingFrameType = broadcast or multicast, this object
	    is NOT APPLICABLE.
	    If maskingFrameType = all or unknown, this object is 
	    applicable.
        The destination address is according to the maskingMacOrNet and maskingProtocolType variables. 
        In case of 'MAC' enter 6 bytes (48 bit) of source address.
        In case of 'NET' 
            if the    maskingProtocolType is IP, this is the IP address
            if the    maskingProtocolType is IPX, this is the IPX address 
                 (nnnnmmmmmmss)
                                nnnn   - IPX net address
                                mmmmmm - Node address (Mac)
                                ss     - IPX socket.
        In case of 'Apple' 
                                nn - net address (4 nibbles) 
                                ss - socket (4 nibbles).
        The IPX socket entered here has priority over the value of
        maskingLowLevelProt, when it is ipxRip, ipxSap or ipxSpx, 
        unless the entered IPX socket is don't care. "   
    ::= {    maskingEntry 12  }

   maskingDestActiveBits OBJECT-TYPE
    SYNTAX  GenAddress
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	   "If maskingFrameType = broadcast or multicast, this object
	    is NOT APPLICABLE.
	    If maskingFrameType = all or unknown, this object is 
	    applicable.
	    Specifies the positions of the wild card characters (*) 
	    in the    maskingDestAddress field. Only the 1's bit will be taken in 
        considerations."
    ::= {    maskingEntry 13   }

   maskingDestMacOrNet OBJECT-TYPE
    SYNTAX  INTEGER {
    macAddress  (1),
    netAddress  (2),
    ipRange     (3),
    appleAddress(4)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"If maskingFrameType = broadcast or multicast, this object
	 is NOT APPLICABLE.
	 If maskingFrameType = all or unknown, this object is 
	 applicable.
	 -  If maskingProtocolType = 'all', 'sna', 'netbios', dec or 
		'unknown', the maskingDestMacOrNet can be macAddress only!
	 -  If maskingProtocolType = 'ip' the 
		maskingDestMacOrNet can be  macAddress or netAddress or 
		appleAddress. 
	 -  If maskingProtocolType = 'ipx', the 
		maskingDestMacOrNet can be either macAddress or netAddress. 
	 -  If maskingProtocolType = 'apple', the 
		maskingDestMacOrNet can be either macAddress or appleAddress. 
     The variable maskingDestAddress and maskingDestActiveBits will 
	 be treated as MAC, or NET address.	"
    ::= {    maskingEntry 14  }

   maskingDestCondition OBJECT-TYPE
    SYNTAX  INTEGER {
    false (1),
    true (2)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"If maskingFrameType = broadcast or multicast, this object
	 is NOT APPLICABLE.
	 If maskingFrameType = all or unknown, this object is 
	 applicable.
	Specifies the logical condition of the mask pattern:

	true  - Condition is valid if at the position specified by 
	           maskingDestAddress (in conjunction with maskingDestActiveBits) 
	        the packet contains data that matches the content of maskingDestAddress.

	false - Condition is valid if at the position specified by 
		   maskingDestAddress (in conjunction with maskingDestActiveBits) 
		the packet contains data that does not match the content of maskingDestAddress."
    ::= {    maskingEntry 15  }

   maskingLowLevelProt OBJECT-TYPE
    SYNTAX  INTEGER {
      unknown (1), -- don't care
      ipxRip  (2), -- 0x51
      ipxSap  (3), -- 0x52
      ipxSpx  (4), -- 0x53
      ipUdp   (5), -- 0x54
      ipTcp   (6), -- 0x55
      ipIcmp  (7), -- 0x56
	ipxNcp  (8), -- 0x57
	ipxWan  (9), -- 0x58
	ipxEco (10), -- 0x59
	ipxErr (11), -- 0x5a
	ipxPep (12)  -- 0x5b 
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
         "This field is set in conjunction with the maskingProtocolType variable.
          This variable specifies the low level protocol.
          The IPX socket entered in maskingDestAddress has priority 
          over the value of maskingLowLevelProt, when it is ipxRip, 
          ipxSap or ipxSpx, unless the entered IPX socket is don't 
          care."
    ::= {    maskingEntry 16  }

   maskingLowLevelProtCondition OBJECT-TYPE
    SYNTAX  INTEGER {
    false  (1),
    true (2)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"Specifies the logical condition of the mask pattern:

	true  - Condition is valid if at the position specified by 
    	   maskingLowLevelProt the packet contains data that matches
		the content of maskingLowLevelProt.

	false - Condition is valid if at the position specified by 
		   maskingLowLevelProt the packet contains data that does not
		match the content of maskingLowLevelProt."
    ::= {    maskingEntry 17  }

   maskingHighLevelProt OBJECT-TYPE
    SYNTAX  Integer32 
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
         "This field is set in connection to the maskingProtocolType variable.
          This variable specifies the high level protocols (application).
          As for today it supports just IP protocol stack.
          The object's value is a sum of the following instances values 
          (selected by user):  
                     none     (0), -- don't care
    			   ftp      (1), 
    			   ftpC     (2), 
    			   telnet   (4), 
    			   smtp     (8),
    			   tftp     (16),
    			   snmp     (32),
    			   snmpTrap (64),
			       ipRip    (128),
			       www      (256),
			       email    (512),
			       dns      (1024),
                     
                     For Apple Protocol only:
                     rtmp     (2048), 
                     nbp      (4096), 
                     atp      (8192), 
                     aep      (16384), 
                     zip      (32768), 
                     adsp     (65536),
					 pap      (131072),
					 asp      (262144)
 
          Example: if ftp(1), snmp(32) and snmpTrap(64) instances 
                   were selected, the value should be 97 (=1+32+64)."
    ::= {    maskingEntry 18  }

   maskingHighLevelProtCondition OBJECT-TYPE
    SYNTAX  INTEGER {
    false  (1),
    true (2)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"Specifies the logical condition of the mask pattern:

	true  - Condition is valid if at the position specified by 
		   maskingHighLevelProt the packet contains data that matches
		the content of    maskingHighLevelProt.

	false - Condition is valid if at the position specified by 
		   maskingHighLevelProt the packet contains data that does not
		match the content of    maskingHighLevelProt."
    ::= {    maskingEntry 19  }

   maskingPortNum OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
        "The port number is the same as in high level protocol. It 
         specifies the dest. port in IP case or the dest. socket 
         in case of IPX & apple protocols.
		 IP  -  This object is applicable only if none (0) value was selected in
		        maskingHighLevelProt.
         IPX -  This object is applicable only if the socket 
                entered in maskingDestAddress is 'don't care'(00) AND
			    maskingLowLevelProt is NOT ipxRip or ipxSap.
	     Apple - This option is applicable only if the socket 
                entered in maskingDestAddress is 'don't care'(00)."
    ::= {    maskingEntry 20  }

   maskingPortNumCondition OBJECT-TYPE
    SYNTAX  INTEGER  {
    false  (1),
    true (2)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"Specifies the logical condition of the mask pattern:

	true  - Condition is valid if at the position specified by 
		   maskingPortNum the packet contains data that matches
		the content of    maskingPortNum.

	false - Condition is valid if at the position specified by 
		   maskingPortNum the packet contains data that does not
		match the content of    maskingPortNum.
	 This object is applicable only when maskingPortNum is applicable."
    ::= {    maskingEntry 21  }

 
maskingOperation OBJECT-TYPE
    SYNTAX INTEGER { 
       block         (1),
       forward       (2),
       route         (3),
       forward-route (4),
       high-priority (5),
       noOp          (6),
       delete        (7),
       smartMask     (8)
}
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
	"The type of action to be taken if the frame meets the 
     conditions of the mask.
       noOp = disabled (mask remains on list, but is not active) 
	 delete = mask is removed from the list.
	 smartMask = the operation and destination of the mask will
	             be determined by the objects of the Smart Table 
	             (old masking table: radBridgeMaskTable). 
     If maskingType is codConnect, the 'block' value is NOT 
     allowed. 
     If maskingType is codDisconnect, the 'forward' value is NOT 
     allowed."     
     ::= {  maskingEntry 22 }    

maskingSrcPortNum OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
        "The source port number.
         For IP:   No Condition.
         For IPX:  This object is applicable only if the socket entered in
                   maskingSourceAddress is don't care (00) and maskingLowLevelProt
                   is NOT ipxRip or ipxSap.
         For Apple:This object is applicable only if the socket entered in
                   maskingSourceAddress is don't care (00). "
    ::= {    maskingEntry 23  }

maskingSrcPortNumCondition OBJECT-TYPE
    SYNTAX  INTEGER  {
    false  (1),
    true (2)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"The same as 'maskingPortNumCondition'.
       Relates to source port."
    ::= {  maskingEntry 24  }
 

radBridgePerformance      OBJECT IDENTIFIER ::= {genBridge 7 }

 -- The RAD Bridge current table contains statistics being
 -- collected for the current 15 minute interval.

 radBridgeCurrentTable OBJECT-TYPE
     SYNTAX  SEQUENCE OF RadBridgeCurrentEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
             "The RAD Bridge Current table."
     ::= { radBridgePerformance 1 }

 radBridgeCurrentEntry OBJECT-TYPE
     SYNTAX  RadBridgeCurrentEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
             "An entry in the RAD Bridge Current table."
     INDEX   { radBridgeCurrentIndex }
     ::= { radBridgeCurrentTable 1 }

 RadBridgeCurrentEntry ::=
     SEQUENCE {
      radBridgeCurrentIndex	  
           Integer32,
      radBridgeCurrentIngressFilteringDiscardedFrames
             Gauge32,
      radBridgeCurrentFrameTypeDiscardedFrames
             Gauge32
 		  }

radBridgeCurrentIndex OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The index of the Bridge interface. 
        It may be ifIndex."
    ::= { radBridgeCurrentEntry 1 }

radBridgeCurrentIngressFilteringDiscardedFrames OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The counter associated with the number of Discarded 
        Frames upon Ingress Filtering, encountered by a Bridge
        interface in the current 15 minute interval."
    ::= { radBridgeCurrentEntry 2 }

radBridgeCurrentFrameTypeDiscardedFrames OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The counter associated with the number of Discarded 
        Frames upon Frame Type and Tagging Mismatch, encountered 
        by a Bridge interface in the current 15 minute interval."
    ::= { radBridgeCurrentEntry 3 }



--Interval Table

-- The RAD Bridge Interval table contains statistics being
-- collected by each Interface over the previous 24
-- hours of operation.  The past 24 hours are broken into 96
-- completed 15 minute intervals.

radBridgeIntervalTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF RadBridgeIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
            "The RAD Bridge Interval table."
    ::= { radBridgePerformance 2 }

radBridgeIntervalEntry OBJECT-TYPE
    SYNTAX  RadBridgeIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
            "An entry in the RAD Bridge Interval table."
    INDEX   { radBridgeIntervalIndex, radBridgeIntervalNumber }
    ::= { radBridgeIntervalTable 1 }

RadBridgeIntervalEntry ::=
    SEQUENCE {
     radBridgeIntervalIndex	  
          Integer32,
     radBridgeIntervalNumber
         Integer32,
     radBridgeIntervalIngressFilteringDiscardedFrames
            Gauge32,
     radBridgeIntervalFrameTypeDiscardedFrames
            Gauge32
	  }

radBridgeIntervalIndex OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
    "The index of the bridge interface. 
    It may be ifIndex."
    ::= { radBridgeIntervalEntry 1 }

radBridgeIntervalNumber OBJECT-TYPE
    SYNTAX  Integer32 (1..96)
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
    "A number between 1 and 96, where 1 is the most
     recently completed 15 minute interval and 96 is
     the least recently completed 15 minutes interval
     (assuming that all 96 intervals exist)."
    ::= { radBridgeIntervalEntry 2 }

radBridgeIntervalIngressFilteringDiscardedFrames OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
    "The counter associated with the number of Discarded 
    Frames upon Ingress Filtering, encountered by a 
    Bridge interface in one of the previous 96, individual 
    15 minute, intervals."
    ::= { radBridgeIntervalEntry 3 }

radBridgeIntervalFrameTypeDiscardedFrames OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
    "The counter associated with the number of Discarded 
    Frames upon Frame Type and Tagging Mismatch, encountered 
    by a Bridge interface in one of the previous 96, individual 
    15 minute, intervals."
    ::= { radBridgeIntervalEntry 4 }


radBridgePortBaseVlan      OBJECT IDENTIFIER ::= {genBridge 8 }

radBridgePortBaseVlanTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF RadBridgePortBaseVlanEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
    "A table containing static configuration information for
     each VLAN configured into the device by  management.
     All entries are permanent and will
     be restored after the device is reset."
    ::= { radBridgePortBaseVlan 1 }

radBridgePortBaseVlanEntry  OBJECT-TYPE
    SYNTAX      RadBridgePortBaseVlanEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
    "Static information for a VLAN configured into the
    device by (local or network) management."
    INDEX   { radBridgePortBaseVlanCnfgIdx,radBridgePortBaseVlanIdx }
    ::= { radBridgePortBaseVlanTable 1 }

RadBridgePortBaseVlanEntry ::=
    SEQUENCE {
        radBridgePortBaseVlanCnfgIdx       Integer32,
        radBridgePortBaseVlanIdx           Integer32,
        radBridgePortBaseVlanName          SnmpAdminString,
        radBridgePortBaseVlanEgressPorts   PortList,
        radBridgePortBaseVlanVirtualGroups PortList,
        radBridgePortBaseVlanRowStatus     RowStatus,
		radBridgePortBaseVlanMng		   INTEGER
    }

radBridgePortBaseVlanCnfgIdx OBJECT-TYPE
    SYNTAX  Integer32 (1..255)
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
    "This object indicates the Idx of the Agent Cnfg the following 
     objects refer.
     255=Temporary Cnfg (when relevant, 
     Set is done only to this configuration).
     For Agents that support only one configuration, 
     this object will be  constant=1. "
    ::= { radBridgePortBaseVlanEntry 1 }

radBridgePortBaseVlanIdx OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
    "Index of the port based VLAN."
    ::= { radBridgePortBaseVlanEntry 2 }

radBridgePortBaseVlanName OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..32))
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
    "An administratively assigned string, which may be used
     to identify the the port based VLAN."
    ::= { radBridgePortBaseVlanEntry 3 }

radBridgePortBaseVlanEgressPorts OBJECT-TYPE
    SYNTAX      PortList
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
    "The set of ports which are permanently assigned to the
    egress list for this port based VLAN by management.  
    The default value of this object is a string of zeros."
    ::= { radBridgePortBaseVlanEntry 4 }


radBridgePortBaseVlanVirtualGroups OBJECT-TYPE
    SYNTAX      PortList
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
    "The set of Virtual Groups which are permanently assigned to
     this port based VLAN by management. 
     (read Virtual Group instead of port in PortList Textual Convention)
     The default value of this object is a string of zeros."
    ::= { radBridgePortBaseVlanEntry 5 }


radBridgePortBaseVlanRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
    "This object enable user to 
     create/delete entries in this table."
    ::= { radBridgePortBaseVlanEntry 6 }
 
radBridgePortBaseVlanMng  OBJECT-TYPE		   
   SYNTAX         INTEGER
      {
      notApplicable  (1),
	  disable		 (2),
	  enable		 (3)
   	  }
    MAX-ACCESS     read-create
    STATUS         current
    DESCRIPTION
    "This object allows user to enable/disable 
    management traffic on this VLAN."
    ::= { radBridgePortBaseVlanEntry 7 }


-- The Bridge's Ports-VLANs Memebership Table

radBridgePortVlanMemberTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF RadBridgePortVlanMemberEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
	"The Bridge Ports-VLAN Membership table.
	 This table enables the user to assign:
	 - Several VLANs to a Port.
	 - Several Ports to a VLAN."
    ::= { radBridgePortBaseVlan 2 }

radBridgePortVlanMemberEntry OBJECT-TYPE
    SYNTAX  RadBridgePortVlanMemberEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
    "An entry in the Bridge Ports-VLANs Memebership table."
    INDEX   { radBridgePortVlanMemberBridgeIdx, 
    		  radBridgePortVlanMemberPortIdx, 
    		  radBridgePortVlanMemberVlanId }
    ::= { radBridgePortVlanMemberTable 1 }

RadBridgePortVlanMemberEntry ::=
    SEQUENCE {
		radBridgePortVlanMemberBridgeIdx	Integer32,
		radBridgePortVlanMemberPortIdx		Integer32,
		radBridgePortVlanMemberVlanId		Integer32,
		radBridgePortVlanMemberRowStatus	RowStatus
    }

radBridgePortVlanMemberBridgeIdx OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
    "This object indicates the Bridge Index."
    ::= { radBridgePortVlanMemberEntry 1 }

radBridgePortVlanMemberPortIdx OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
    "This object indicates the Bridge's Port Index.
     For some cases, it can be used as the Port ofIndex."
    ::= { radBridgePortVlanMemberEntry 2 }

radBridgePortVlanMemberVlanId OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
    "This object indicates the VLAN ID."
    ::= { radBridgePortVlanMemberEntry 3 }
	
radBridgePortVlanMemberRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
    "This object enables the user to 
     create/delete entries in this table."
    ::= { radBridgePortVlanMemberEntry 4 }

radBridgeGenCnfg      OBJECT IDENTIFIER ::= {genBridge 9 }


radBridgeGenFlowTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF RadBridgeGenFlowEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
    "A table containing static configuration information for
    Bridge configured into the device by (local or
    network) management.  All entries are permanent and will
    be restored after the device is reset."
    ::= {  radBridgeGenCnfg 1 }

radBridgeGenFlowEntry  OBJECT-TYPE
    SYNTAX      RadBridgeGenFlowEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
    "Static information for a Bridge configured into the
    device by  management."
    INDEX   { radBridgeGenFlowCnfgIdx,radBridgeGenFlowIdx }
    ::= { radBridgeGenFlowTable 1 }

RadBridgeGenFlowEntry ::=
SEQUENCE
    { 
    radBridgeGenFlowCnfgIdx                    Integer32,
    radBridgeGenFlowIdx                        Integer32,
    radBridgeGenFlowRowStatus                  RowStatus,
    radBridgeGenFlowFloodOrBcastMaxRate 	   Integer32,
    radBridgeGenFlowQosMode                    INTEGER,
    radBridgeGenFlowSchedulingMode             INTEGER 

    }

radBridgeGenFlowCnfgIdx OBJECT-TYPE
    SYNTAX  Integer32 (1..255)
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
    "This object indicates the Idx of the 
     Agent Cnfg the following objects refer.
     255=Temporary Cnfg (when relevant, 

     Set is done only to this configuration).
     For Agents that support only one configuration, 
     this object will be  constant=1. "
    ::= { radBridgeGenFlowEntry 1 }

radBridgeGenFlowIdx OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
    "For Agent having more than one bridge, 
     this index may be used as bridge index "
    ::= { radBridgeGenFlowEntry 2 }

radBridgeGenFlowRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
    "This object enable user to 
     create/delete entries in this table."
    ::= { radBridgeGenFlowEntry 3 }


radBridgeGenFlowFloodOrBcastMaxRate OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
    "This object controls maximum Flooding or Broadcast Rate:
     Max number of multicast along with unknown 
     or flooded unicast frames allowed to enter 
     any port. 
     The number is presented as percentage of bandwidth.        
     Once the limit is exceeded, any multicast or flooded 
     frame entering from the port is discarded
     For RIC-155 valid values are 0-100 
     For FCD-155 valid values are 3% , 6%, 12% 
     and 100% = No Limit "
    ::= { radBridgeGenFlowEntry 4 }


radBridgeGenFlowQosMode OBJECT-TYPE
    SYNTAX      INTEGER
    {
     notApplicable   (1),
     vlanTag         (2),
     dscp            (3),
     dscpAndVlanTag  (4),
     vlanTagAndDscp  (5),
	 none			 (6)
          }
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
    "This object controls Quality of Service mode.
    User may select which field(s) 
    (in case of fields -  which one has precedence) 
    will affect prioritization of data between egress queues."
    ::= { radBridgeGenFlowEntry 5 }

radBridgeGenFlowSchedulingMode  OBJECT-TYPE
    SYNTAX      INTEGER
    {
     notApplicable (1),
     wfq           (2), -- Weighted Fair Queuing
     sp            (3)  -- Strict Priority
          }
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
    "This object controls which scheduling mode is used:
     Weighted Fair Queuing (WFQ) scheme or Strict Priority (SP)."
    ::= { radBridgeGenFlowEntry 6 }

radBridgeStatus      OBJECT IDENTIFIER ::= {genBridge 10 }

radBridgeInvBasePortTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF RadBridgeInvBasePortEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
    "An inversed table to dot1dBasePortTable 
     from RFC1493 with reduced information.
     This table index is known to the NMS and 
     this way the needed information can be received
     by just one Get command, instead of searching 
     the entire dot1dBasePortTable (where it is an 
     attribute). "
    ::= { radBridgeStatus 1 }

radBridgeInvBasePortEntry OBJECT-TYPE
    SYNTAX  RadBridgeInvBasePortEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
    "The bridge port number for each bridge port 
     interface index."
     INDEX  { radBridgeInvBasePortIfIndex }
    ::= { radBridgeInvBasePortTable 1 }

RadBridgeInvBasePortEntry ::=
    SEQUENCE {
    radBridgeInvBasePortIfIndex	Integer32,
    radBridgeInvBasePort		Integer32
              }

radBridgeInvBasePortIfIndex OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
    "The value of the instance of the ifIndex object,
     defined in MIB-II, for the interface corresponding
     to this Bridge port."
    ::= { radBridgeInvBasePortEntry 1 }

radBridgeInvBasePort OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
    "The Bridge port number."
    ::= { radBridgeInvBasePortEntry 2 }


-- END -- 
-- file :v:\doc\rdv\mib\ver495\radsonet.txt
-- 
-- RAD-SONET-MIB DEFINITIONS ::= BEGIN

--Title:    RAD-SONET   MIB	 ver495
--

--     IMPORTS
--     Gauge32                         FROM RFC1155-SMI
--     ifIndex                         FROM RFC1213-MIB
--     OBJECT-TYPE                     FROM RFC-1212
--     radWan                          FROM RAD-GEN-MIB;



--                RAD-SONET MIB   

--Title:     RAD's SONET INTERFACE MIB
--Version:   1.0
--Date:      13.10.96
--By:        Yair Arian
--File:      sonet.mib
--
--Last update: 25-Septemper-2002 by Yig'al Hachmon



sonetInterface  OBJECT IDENTIFIER  ::=  {diverseIfWanGen 2}

prtSonetPerfHistory  OBJECT IDENTIFIER  ::=  {sonetInterface 1}


-- The SONET Medium Table

prtSonetMediumTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF PrtSonetMediumEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
            "The SONET Medium table."
    ::= { prtSonetPerfHistory 1 }

prtSonetMediumEntry OBJECT-TYPE
    SYNTAX  PrtSonetMediumEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
            "An entry in the SONET Medium table. ifIndex of the
             lowest SONET layer of type sonet(39)."
    INDEX   { ifIndex }
    ::= { prtSonetMediumTable 1 }

PrtSonetMediumEntry ::=
    SEQUENCE {
        prtSonetMediumTimeElapsed
            Integer32,
        prtSonetMediumValidIntervals
            Integer32
           }

 prtSonetMediumTimeElapsed OBJECT-TYPE
     SYNTAX  Integer32 (0..899)
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
             "The number of seconds that have elapsed since
             the beginning of the near end current error-
             measurement period."
    ::= { prtSonetMediumEntry 1 }

prtSonetMediumValidIntervals OBJECT-TYPE
    SYNTAX  Integer32 (0..96)
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The number of previous near end intervals for
            which valid data was collected.  The value will be
            96 unless the interface was brought online within
            the last 24 hours, in which case the value will be
            the number of complete 15 minute near end
            intervals since the interface has been online."
    ::= { prtSonetMediumEntry 2 }


-- The SONET Section/Line Current	Table

-- The SONET Section/Line Current table contains various statistics being
-- collected for the current 15 minute interval.

prtSonetSectionLineCurrentTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF PrtSectionLineCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
            "The SONET Section/Line Current table."
    ::= { prtSonetPerfHistory 2 }

prtSectionLineCurrentEntry OBJECT-TYPE
    SYNTAX  PrtSectionLineCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
            "An entry in the SONET Section/Line Current table.
             ifIndex of the section/line SONET layer of type 
             sonet(39)."
    INDEX   { ifIndex }
    ::= { prtSonetSectionLineCurrentTable 1 }

PrtSectionLineCurrentEntry ::=
    SEQUENCE {
        prtSonetCurrentLOS
            Gauge32,
        prtSonetCurrentLOF
            Gauge32,
        prtSonetCurrentLineAIS
            Gauge32,
        prtSonetCurrentLineFERF
            Gauge32,
        prtSonetCurrentSectionBIP
            Gauge32,
        prtSonetCurrentLineBIP
            Gauge32,
        prtSonetCurrentLineFEBE
            Gauge32,
        prtSonetCurrentUAS
            Gauge32,
        prtSonetCurrentSES
            Gauge32,
        prtSonetCurrentES 
            Gauge32,
        prtSonetCurrentStatus 
            OCTET STRING,
        prtSonetCurrentLSV 
            Gauge32

    }

prtSonetCurrentLOS OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of LOS
             seconds, encountered by a SONET interface in
            the current 15 minute interval."
    ::= { prtSectionLineCurrentEntry 1 }

prtSonetCurrentLOF OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of LOF
             seconds, encountered by a SONET
             interface in the current 15 minute interval."
    ::= { prtSectionLineCurrentEntry 2 }

prtSonetCurrentLineAIS OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of Line AIS
            seconds, encountered by a SONET
            interface in the current 15 minute interval."
    ::= { prtSectionLineCurrentEntry 3 }

prtSonetCurrentLineFERF OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of Line
            FERF seconds, encountered by a SONET
            interface in the current 15 minute interval."
    ::= { prtSectionLineCurrentEntry 4 }

prtSonetCurrentSectionBIP OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of Section
            BIP errors, encountered by a SONET
            interface in the current 15 minute interval."
    ::= { prtSectionLineCurrentEntry 5 }

prtSonetCurrentLineBIP OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of Line
            BIP errors, encountered by a SONET
            interface in the current 15 minute interval."
    ::= { prtSectionLineCurrentEntry 6 }

prtSonetCurrentLineFEBE OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of Line
            FEBE errors, encountered by a SONET
            interface in the current 15 minute interval."
    ::= { prtSectionLineCurrentEntry 7 }

prtSonetCurrentUAS OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of UAS
             encountered by a SONET
             interface in the current 15 minute interval."
    ::= { prtSectionLineCurrentEntry 8 }

prtSonetCurrentSES OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of SES
             encountered by a SONET
             interface in the current 15 minute interval."
    ::= { prtSectionLineCurrentEntry 9 }

prtSonetCurrentES OBJECT-TYPE
     SYNTAX Gauge32 
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
            "The number of Errored Seconds, encountered  by a
              SONET interface in the current 15 minute interval."
     ::= { prtSectionLineCurrentEntry 10 }

prtSonetCurrentStatus OBJECT-TYPE
     SYNTAX OCTET STRING  (SIZE (4))
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The statuses of the current interval:
              0 - O.K.
              1 - The link has been switched by a redundancy mechanism.
              2 - Module is in/out.
              4 - Empty - card is out."
    ::= { prtSectionLineCurrentEntry 11 }

prtSonetCurrentLSV OBJECT-TYPE
     SYNTAX  Gauge32
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
             "The counter associated with the number of LSV
              seconds (Line Symbol Violation), encountered by a 
              SONET interface in the current 15 minute interval."
     ::= { prtSectionLineCurrentEntry 12 }


 -- The SONET Section/Line interface Interval

 -- The SONET Section/Line Interval Table contains various statistics
 -- collected by the Interface over the previous 24
 -- hours of operation.  The past 24 hours are broken into 96
 -- completed 15 minute intervals.

 prtSonetSectionLineIntervalTable OBJECT-TYPE
     SYNTAX  SEQUENCE OF PrtSectionLineIntervalEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
             "The Section/Line Interval table."
     ::= { prtSonetPerfHistory 3 }

 prtSectionLineIntervalEntry OBJECT-TYPE
     SYNTAX  PrtSectionLineIntervalEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
             "An entry in the SONET Section/Line Interval table.
              ifIndex of the section/line SONET layer of type 
              sonet(39)."
     INDEX   { ifIndex, prtSonetLineIntervalNumber }
     ::= { prtSonetSectionLineIntervalTable 1 }

PrtSectionLineIntervalEntry ::=
     SEQUENCE {
         prtSonetLineIntervalNumber
             Integer32,
         prtSonetIntervalLOS
             Gauge32,
         prtSonetIntervalLOF
             Gauge32,
         prtSonetIntervalLineAIS
             Gauge32,
         prtSonetIntervalLineFERF
             Gauge32,
         prtSonetIntervalSectionBIP
             Gauge32,
         prtSonetIntervalLineBIP
             Gauge32,
         prtSonetIntervalLineFEBE
             Gauge32,
         prtSonetIntervalUAS
             Gauge32,
         prtSonetIntervalSES
             Gauge32,
         prtSonetIntervalES
             Gauge32,
	  prtSonetIntervalStatus
             OCTET STRING,
	  prtSonetIntervalLSV
             Gauge32    }

prtSonetLineIntervalNumber OBJECT-TYPE
    SYNTAX  Integer32 (1..96)
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "A number between 1 and 96, where 1 is the most
            recently completed 15 minute interval and 96 is
            the least recently completed 15 minutes interval
            (assuming that all 96 intervals are valid)."
    ::= { prtSectionLineIntervalEntry 1 }

prtSonetIntervalLOS OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of LOS
            seconds , encountered by a SONET interface in
            one of the previous 96, individual 15 minute,
            intervals."
    ::= { prtSectionLineIntervalEntry 2 }

prtSonetIntervalLOF OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of LOF
            seconds, encountered by a SONET
            interface in one of the previous 96, individual 15
            minute, intervals."
    ::= { prtSectionLineIntervalEntry 3 }

prtSonetIntervalLineAIS OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
           "The counter associated with the number of Line
           AIS seconds, encountered by a SONET
           interface in one of the previous 96,
           individual 15 minute, intervals."
   ::= { prtSectionLineIntervalEntry 4 }

prtSonetIntervalLineFERF OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of Line
            FERF seconds, encountered by a SONET
            interface in one of the previous 96, individual 15
            minute, intervals."
    ::= { prtSectionLineIntervalEntry 5 }

prtSonetIntervalSectionBIP OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of Section
            BIP errors, encountered by a SONET
            interface in one of the previous 96, individual 15
            minute, intervals."
    ::= { prtSectionLineIntervalEntry 6 }

prtSonetIntervalLineBIP OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of Line
            BIP errors, encountered by a SONET 
            interface in one of the previous 96, individual 15
            minute, intervals."
    ::= { prtSectionLineIntervalEntry 7 }

prtSonetIntervalLineFEBE OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of Line
            FEBE errors, encountered by a SONET
            interface in one of the previous 96, individual 15
            minute, intervals."
    ::= { prtSectionLineIntervalEntry 8 }

prtSonetIntervalUAS OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
             "The counter associated with the number of UAS
             encountered by a SONET
             interface in one of the previous 96, individual 15
             minute, intervals."
     ::= { prtSectionLineIntervalEntry 9 }

prtSonetIntervalSES OBJECT-TYPE
     SYNTAX  Gauge32
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
             "The counter associated with the number of SES
             encountered by a SONET
             interface in one of the previous 96, individual 15
             minute, intervals."
     ::= { prtSectionLineIntervalEntry 10 }

prtSonetIntervalES OBJECT-TYPE
     SYNTAX Gauge32 
     MAX-ACCESS  read-only
     STATUS current 
     DESCRIPTION
            "The number of Errored Seconds, encountered  by a
            SONET interface in one of the previous 96, individual 15
            minute, intervals."
     ::= { prtSectionLineIntervalEntry 11 }

prtSonetIntervalStatus OBJECT-TYPE
     SYNTAX OCTET STRING  (SIZE (4))
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
             " The statuses of the current interval:
               0 - O.K.
               1 - The link has been switched by a redundancy mechanism.
               2 - Module is in/out.
               4 - Empty - card is out."
     ::= { prtSectionLineIntervalEntry 12 }

prtSonetIntervalLSV OBJECT-TYPE
     SYNTAX  Gauge32
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
             "The counter associated with the number of LSV seconds 
             (Line Symbol Violation), encountered by a SONET interface 
             in one of the previous 96, individual 15 minute, intervals."
     ::= { prtSectionLineIntervalEntry 13 }
                             
        
  -- The SONET Path Current	Table

-- The SONET Path Current table contains various statistics being
-- collected for the current 15 minute interval.

prtSonetPathCurrentTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF PrtPathCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
            "The SONET Path Current table."
    ::= { prtSonetPerfHistory 4 }

prtPathCurrentEntry OBJECT-TYPE
    SYNTAX  PrtPathCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
            "An entry in the SONET Path Current table.
             ifIndex of the Path SONET layer of type 
             sonetPath(50)."
    INDEX   { ifIndex }
    ::= { prtSonetPathCurrentTable 1 }

PrtPathCurrentEntry ::=
    SEQUENCE {
        prtSonetCurrentPathAIS
            Gauge32,
        prtSonetCurrentPathFERF
            Gauge32,
        prtSonetCurrentLOP
            Gauge32,
        prtSonetCurrentSLM
            Gauge32,
        prtSonetCurrentLOC
            Gauge32,
        prtSonetCurrentPathBIP
            Gauge32,
        prtSonetCurrentPathFEBE
            Gauge32
    }

prtSonetCurrentPathAIS OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of Path AIS
             seconds, encountered by a SONET interface in
            the current 15 minute interval."
    ::= { prtPathCurrentEntry 1 }

prtSonetCurrentPathFERF OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of Path FERF
             seconds, encountered by a SONET
             interface in the current 15 minute interval."
    ::= { prtPathCurrentEntry 2 }

prtSonetCurrentLOP OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number LOP
            seconds, encountered by a SONET
            interface in the current 15 minute interval."
    ::= { prtPathCurrentEntry 3 }

prtSonetCurrentSLM OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of SLM
             seconds, encountered by a SONET
             interface in the current 15 minute interval."
    ::= { prtPathCurrentEntry 4 }

prtSonetCurrentLOC OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of LOC
            seconds, encountered by a SONET
            interface in the current 15 minute interval."
    ::= { prtPathCurrentEntry 5 }

prtSonetCurrentPathBIP OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of Path
            BIP errors, encountered by a SONET
            interface in the current 15 minute interval."
    ::= { prtPathCurrentEntry 6 }

prtSonetCurrentPathFEBE OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of Path
            FEBE errors, encountered by a SONET
            interface in the current 15 minute interval."
    ::= { prtPathCurrentEntry 7 }


-- The SONET Path interface Interval

-- The SONET Path Interval Table contains various statistics
-- collected by the Interface over the previous 24
-- hours of operation.  The past 24 hours are broken into 96
-- completed 15 minute intervals.

prtSonetPathIntervalTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF PrtPathIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
            "The Path Interval table."
    ::= { prtSonetPerfHistory 5 }

prtPathIntervalEntry OBJECT-TYPE
    SYNTAX  PrtPathIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
            "An entry in the SONET Path Interval table."
    INDEX   { ifIndex, prtSonetPathIntervalNumber }
    ::= { prtSonetPathIntervalTable 1 }

PrtPathIntervalEntry ::=
    SEQUENCE {
        prtSonetPathIntervalNumber
            Integer32,
        prtSonetIntervalPathAIS
            Gauge32,
        prtSonetIntervalPathFERF
            Gauge32,
        prtSonetIntervalLOP
            Gauge32,
        prtSonetIntervalSLM
            Gauge32,
        prtSonetIntervalLOC
            Gauge32,
        prtSonetIntervalPathBIP
            Gauge32,
        prtSonetIntervalPathFEBE
            Gauge32
    }

prtSonetPathIntervalNumber OBJECT-TYPE
    SYNTAX  Integer32 (1..96)
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "A number between 1 and 96, where 1 is the most
            recently completed 15 minute interval and 96 is
            the least recently completed 15 minutes interval
            (assuming that all 96 intervals are valid)."
    ::= { prtPathIntervalEntry 1 }

prtSonetIntervalPathAIS OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of Path
            AIS seconds , encountered by a SONET interface in
            one of the previous 96, individual 15 minute,
            intervals."
    ::= { prtPathIntervalEntry 2 }

prtSonetIntervalPathFERF OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of Path
            FERF seconds, encountered by a SONET
            interface in one of the previous 96, individual 15
            minute, intervals."
    ::= { prtPathIntervalEntry 3 }

prtSonetIntervalLOP OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of LOP
            seconds, encountered by a SONET
            interface in one of the previous 96,
            individual 15 minute, intervals."
    ::= { prtPathIntervalEntry 4 }

prtSonetIntervalSLM OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of SLM
            seconds, encountered by a SONET
            interface in one of the previous 96, individual 15
            minute, intervals."
    ::= { prtPathIntervalEntry 5 }

prtSonetIntervalLOC OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of LOC
            seconds, encountered by a SONET
            interface in one of the previous 96, individual 15
            minute, intervals."
    ::= { prtPathIntervalEntry 6 }

prtSonetIntervalPathBIP OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of Path
            BIP errors, encountered by a SONET 
            interface in one of the previous 96, individual 15
            minute, intervals."
    ::= { prtPathIntervalEntry 7 }

prtSonetIntervalPathFEBE OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The counter associated with the number of Path
            FEBE errors, encountered by a SONET
            interface in one of the previous 96, individual 15
            minute, intervals."
    ::= { prtPathIntervalEntry 8 }



virtualIfStatistics  OBJECT IDENTIFIER  ::=  { prtSonetPerfHistory 6}


-- the Virtual Interface Current Table

virtualIfCurrentTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF VirtualIfCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "The Virtual Interface Current table."
     ::= { virtualIfStatistics 1 }

virtualIfCurrentEntry OBJECT-TYPE
    SYNTAX  VirtualIfCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "An entry in the Virtual Interface Current table."
    INDEX   { ifIndex  }
     ::= { virtualIfCurrentTable 1 }

VirtualIfCurrentEntry ::=
    SEQUENCE {
 		 virtualIfCurrentMinActiveVC	           Integer32,
 		 virtualIfCurrentMaxActiveVC	           Integer32,
         virtualIfCurrentRxFrames                  Counter64,
         virtualIfCurrentTxFrames				   Counter64,
         virtualIfCurrentRxAbortFrames		   	   PerfCurrentCount,
         virtualIfCurrentTxAbortFrames		   	   PerfCurrentCount,
         virtualIfCurrentMinLengthViolation		   PerfCurrentCount,
         virtualIfCurrentMaxLengthViolation        PerfCurrentCount,
		 virtualIfCurrentFcsError				   PerfCurrentCount,
		 virtualIfCurrentByteDestuffingViolation   PerfCurrentCount,
		 virtualIfCurrentAdressMismatch			   PerfCurrentCount,
		 virtualIfCurrentControlMismatch		   PerfCurrentCount,
		 virtualIfCurrentActiveVC				   Integer32

    }
								
virtualIfCurrentMinActiveVC OBJECT-TYPE
     SYNTAX  Integer32 (1..63)
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
       "This object holds the minimum number of active virtual containers (VCs)  
        of the Virtual Concatenation Group in the current 15-minute interval."
      ::= { virtualIfCurrentEntry 1 }
 
 virtualIfCurrentMaxActiveVC OBJECT-TYPE
     SYNTAX  Integer32 (1..63)
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
       "This object holds the maximum number of active virtual containers (VCs)  
        of the Virtual Concatenation Group in the current 15-minute interval."
      ::= {virtualIfCurrentEntry 2 }

virtualIfCurrentRxFrames OBJECT-TYPE
    SYNTAX  Counter64
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of frames received from STS-3/STM-1 
        by a Virtual Interface in the current 15-minute interval."
     ::= { virtualIfCurrentEntry 3}

virtualIfCurrentTxFrames OBJECT-TYPE
    SYNTAX  Counter64
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of frames transmitted to STS-3/STM-1 
        by a Virtual Interface in the current 15-minute interval."
    ::= { virtualIfCurrentEntry 4 }
 
 virtualIfCurrentRxAbortFrames OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "The counter associated with the number of Received Aborted frames
        encountered by a Virtual Interface in the current 15-minute interval."
      ::= { virtualIfCurrentEntry 5 }

virtualIfCurrentTxAbortFrames OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "The counter associated with the number of Transmitted Aborted frames
        encountered by a Virtual Interface in the current 15-minute interval."
      ::= { virtualIfCurrentEntry 6 }

virtualIfCurrentMinLengthViolation OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        Rx payload Min Length Violation frames encountered by a Virtual Interface 
        in the current 15-minute interval."
    ::= { virtualIfCurrentEntry 7 }

virtualIfCurrentMaxLengthViolation OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        Rx payload Max Length Violation frames  
        encountered by a Virtual Interface in the current 15-minute interval."
    ::= { virtualIfCurrentEntry 8 }

virtualIfCurrentFcsError OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "The counter is associated with the number of
        Frame Check Sequence errors	encountered by a Virtual Interface  
        in the current 15-minute interval."
    ::= { virtualIfCurrentEntry 9 }

virtualIfCurrentByteDestuffingViolation OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "The counter associated with the number of 
        Byte De-stuffing Violations encountered by a Virtual Interface
        in the current 15-minute interval."
    ::= {virtualIfCurrentEntry 10 }
				 

virtualIfCurrentAdressMismatch	 OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "The counter associated with the number of 
        Adress Mismatch encountered by a Virtual Interface
        in the current 15-minute interval."
    ::= {virtualIfCurrentEntry 11 }
 
virtualIfCurrentControlMismatch OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "The counter associated with the number of 
        Control Mismatch encountered by a Virtual Interface
        in the current 15-minute interval."
    ::= {virtualIfCurrentEntry 12 }

virtualIfCurrentActiveVC OBJECT-TYPE
     SYNTAX  Integer32 (1..64)
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
       "This object holds the number of active virtual containers (VCs)  
        of the Virtual Concatenation Group in the current 15-minute interval."
      ::= {virtualIfCurrentEntry 13 }

   

-- the Virtual Interface Interval Table

-- The Virtual Interface Interval Table
-- contains various statistics collected  over a maximum
-- of the previous 24 hours of operation.  
-- The past 24 hours may be broken into 96 
-- completed 15 minute intervals.

virtualIfIntervalTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF VirtualIfIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "The Virtual Interface Interval table."
     ::= { virtualIfStatistics 2 }

virtualIfIntervalEntry OBJECT-TYPE
    SYNTAX  VirtualIfIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "An entry in the Virtual Interface Interval table."
    INDEX   { ifIndex, virtualIfIntervalNumber }
     ::= { virtualIfIntervalTable 1 }

VirtualIfIntervalEntry ::=
    SEQUENCE {
         virtualIfIntervalNumber                   Integer32,
		 virtualIfIntervalMinActiveVC	           Integer32,
		 virtualIfIntervalMaxActiveVC	           Integer32,
         virtualIfIntervalRxFrames                 Counter64,
         virtualIfIntervalTxFrames                 Counter64,
         virtualIfIntervalRxAbortFrames		       PerfIntervalCount,
         virtualIfIntervalTxAbortFrames		       PerfIntervalCount,
         virtualIfIntervalMinLengthViolation       PerfIntervalCount,
         virtualIfIntervalMaxLengthViolation       PerfIntervalCount,
		 virtualIfIntervalFcsError			       PerfIntervalCount,
		 virtualIfIntervalByteDestuffingViolation  PerfIntervalCount,
		 virtualIfIntervalAdressMismatch		   PerfIntervalCount,
		 virtualIfIntervalControlMismatch		   PerfIntervalCount,
		 virtualIfIntervalBelowMinThreshold		   PerfIntervalCount
    }

virtualIfIntervalNumber OBJECT-TYPE
    SYNTAX  Integer32 (1..96)
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
      "A number between 1 and 96, which identifies the
       interval for which the set of statistics is available.
       The interval identified by 1 is the most recently
       completed 15 minute interval,
       and the interval identified
       by N is the interval immediately preceding the
       one identified  by N-1."
     ::= { virtualIfIntervalEntry 1 }

virtualIfIntervalMinActiveVC OBJECT-TYPE
    SYNTAX  Integer32 (1..64)
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
      "This object holds the minimum number of 
       active virtual containers (VCs) of the Virtual Concatenation Group, in a
       particular 15-minute interval in the past 24 hours."
     ::= { virtualIfIntervalEntry 2 }

virtualIfIntervalMaxActiveVC OBJECT-TYPE
    SYNTAX  Integer32 (1..64)
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
      "This object holds the maximum number of 
       active virtual containers (VCs) of the Virtual Concatenation Group, in a
       particular 15-minute interval in the past 24 hours."
     ::= { virtualIfIntervalEntry 3 }

virtualIfIntervalRxFrames OBJECT-TYPE
    SYNTAX  Counter64
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        frames received from STS-3/STM-1 by a Virtual Interface in a
        particular 15-minute interval in the past 24 hours."
    ::= { virtualIfIntervalEntry 4 }

virtualIfIntervalTxFrames OBJECT-TYPE
    SYNTAX  Counter64
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        frames transmitted to STS-3/STM-1 by a Virtual Interface in a
        particular 15-minute interval in the past 24 hours."
    ::= { virtualIfIntervalEntry 5 }

  virtualIfIntervalRxAbortFrames OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        Received Abort frames encountered by a Virtual Interface in a
        particular 15-minute interval in the past 24 hours."
    ::= {virtualIfIntervalEntry 6 }

virtualIfIntervalTxAbortFrames OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        Transmitted Abort frames encountered by a Virtual Interface in a
        particular 15-minute interval in the past 24 hours."
    ::= { virtualIfIntervalEntry 7 }

virtualIfIntervalMinLengthViolation OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        Rx payload Min Length Violation frames  
        encountered by a Virtual Interface in a
        particular 15-minute interval in the past 24 hours."
    ::= { virtualIfIntervalEntry 8 }

virtualIfIntervalMaxLengthViolation OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        Rx payload Max Length Violation frames  
        encountered by a Virtual Interface in a
        particular 15-minute interval in the past 24 hours."
    ::= { virtualIfIntervalEntry 9 }

virtualIfIntervalFcsError OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        Frame Check Sequence errors encountered by a Virtual Interface in a
        particular 15-minute interval in the past 24 hours."
    ::= { virtualIfIntervalEntry 10 }

virtualIfIntervalByteDestuffingViolation OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of 
        Byte De-stuffing Violations
        encountered by a Virtual Interface in a
        particular 15-minute interval in the past 24 hours."
    ::= { virtualIfIntervalEntry 11 }


virtualIfIntervalAdressMismatch	   OBJECT-TYPE 
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        Address Mismatch encountered by a Virtual Interface in a
        particular 15-minute interval in the past 24 hours."
    ::= { virtualIfIntervalEntry 12 }

virtualIfIntervalControlMismatch  OBJECT-TYPE	  
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        Control mismatch encountered by a Virtual Interface in a
        particular 15-minute interval in the past 24 hours."
    ::= { virtualIfIntervalEntry 13 }

virtualIfIntervalBelowMinThreshold	 OBJECT-TYPE		   
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        seconds that number of active VCs was below minimum threshold
		defined by vcGroupCnfgNoOfVCs, 
		encountered by Virtual Interface in a
        particular 15-minute interval in the past 24 hours."
    ::= { virtualIfIntervalEntry 14 }





-- the  Virtual Interface LAPS Current Table

virtualIfLAPSCurrentTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF VcGroupLAPSCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "The Virtual Interface LAPS Current table."
     ::= { virtualIfStatistics 3 }

virtualIfLAPSCurrentEntry OBJECT-TYPE
    SYNTAX  VcGroupLAPSCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "An entry in the Virtual Interface 
        LAPS Current table."
    INDEX   { ifIndex  }
     ::= { virtualIfLAPSCurrentTable 1 }  

VcGroupLAPSCurrentEntry ::=
    SEQUENCE {
           virtualIfLAPSCurrentSapiMismatch            PerfCurrentCount
             }
								

virtualIfLAPSCurrentSapiMismatch OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        received SAPI field mismatch  
        encountered by a Virtual Interface 
        in the current 15-minute interval."
    ::= { virtualIfLAPSCurrentEntry 1 }

				 

-- the Virtual Interface LAPS Interval Table

-- The Virtual Interface LAPS Interval Table
-- contains various statistics collected  over a maximum
-- of the previous 24 hours of operation.  
-- The past 24 hours may be broken into 96 
-- completed 15 minute intervals.

virtualIfLAPSIntervalTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF VirtualIfLAPSIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "The Virtual Interface LAPS table."
     ::= { virtualIfStatistics 4 }

virtualIfLAPSIntervalEntry OBJECT-TYPE
    SYNTAX  VirtualIfLAPSIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "An entry in the Virtual Interface 
       LAPS Interval table."
    INDEX   { ifIndex, virtualIfIntervalNumber }
     ::= { virtualIfLAPSIntervalTable 1 }

VirtualIfLAPSIntervalEntry ::=
    SEQUENCE {
         virtualIfLAPSIntervalSapiMismatch     PerfIntervalCount
              }

virtualIfLAPSIntervalSapiMismatch OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        received SAPI field mismatch 
        encountered by a Virtual Interface in a
        particular 15-minute interval in the past 24 hours."
    ::= { virtualIfLAPSIntervalEntry 1 }


-- the Virtual Interface LAPF Current Table

virtualIfLAPFCurrentTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF VirtualIfLAPFCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "The Virtual Interface LAPF Current table."
     ::= { virtualIfStatistics 5 }

virtualIfLAPFCurrentEntry OBJECT-TYPE
    SYNTAX  VirtualIfLAPFCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "An entry in the Virtual Interface 
        LAPF Current table."
    INDEX   { ifIndex  }
     ::= { virtualIfLAPFCurrentTable 1 }

VirtualIfLAPFCurrentEntry ::=
    SEQUENCE {
		 virtualIfLAPFCurrentNlpidMismatch  PerfCurrentCount,
         virtualIfLAPFCurrentOuiMismatch    PerfCurrentCount,
		 virtualIfLAPFCurrentPidMismatch	  PerfCurrentCount,
		 virtualIfLAPFCurrentDlciMismatch	  PerfCurrentCount,
		 virtualIfLAPFCurrentMacRxFrames    PerfCurrentCount,
		 virtualIfLAPFCurrentMacTxFrames    PerfCurrentCount
    }
								

virtualIfLAPFCurrentNlpidMismatch OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        received NLPID field mismatch  
        encountered by a Virtual Interface 
        in the current 15-minute interval."
    ::= { virtualIfLAPFCurrentEntry 1 }

virtualIfLAPFCurrentOuiMismatch OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        received OUI field mismatch  
        encountered by a Virtual Interface 
        in the current 15-minute interval."
    ::= { virtualIfLAPFCurrentEntry 2 }


virtualIfLAPFCurrentPidMismatch OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        received PID field mismatch  
        encountered by a Virtual Interface 
        in the current 15-minute interval."
    ::= { virtualIfLAPFCurrentEntry 3 }


virtualIfLAPFCurrentDlciMismatch OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        received DLCI field mismatch  
        encountered by a Virtual Interface 
        in the current 15-minute interval."
    ::= { virtualIfLAPFCurrentEntry 4 }


virtualIfLAPFCurrentMacRxFrames OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        frames received from LAN  
        by a Virtual Interface 
        in the current 15-minute interval."
    ::= { virtualIfLAPFCurrentEntry 5 }


virtualIfLAPFCurrentMacTxFrames OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        frames transmitted to LAN
        by a Virtual Interface 
        in the current 15-minute interval."
    ::= { virtualIfLAPFCurrentEntry 6 }


-- the Virtual Interface LAPF Interval Table

-- The Virtual Interface LAPF Interval Table
-- contains various statistics collected  over a maximum
-- of the previous 24 hours of operation.  
-- The past 24 hours may be broken into 96 
-- completed 15 minute intervals.

virtualIfLAPFIntervalTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF VirtualIfLAPFIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "The Virtual Interface LAPF Interval table."
     ::= { virtualIfStatistics 6 }

virtualIfLAPFIntervalEntry OBJECT-TYPE
    SYNTAX  VirtualIfLAPFIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "An entry in the Virtual Interface Interval table."
    INDEX   { ifIndex, virtualIfIntervalNumber }
     ::= { virtualIfLAPFIntervalTable 1 }

VirtualIfLAPFIntervalEntry ::=
    SEQUENCE {
         virtualIfLAPFIntervalNlpidMismatch   PerfIntervalCount,
         virtualIfLAPFIntervalOuiMismatch     PerfIntervalCount,
		 virtualIfLAPFIntervalPidMismatch	  PerfIntervalCount,
		 virtualIfLAPFIntervalDlciMismatch    PerfIntervalCount,
		 virtualIfLAPFIntervalMacRxFrames     PerfIntervalCount,
		 virtualIfLAPFIntervalMacTxFrames     PerfIntervalCount
     }


virtualIfLAPFIntervalNlpidMismatch OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        received NLPID field mismatch 
        encountered by a Virtual Interface in a
        particular 15-minute interval in the past 24 hours."
    ::= { virtualIfLAPFIntervalEntry 1 }


virtualIfLAPFIntervalOuiMismatch OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        received OUI field mismatch 
        encountered by a Virtual Interface in a
        particular 15-minute interval in the past 24 hours."
    ::= { virtualIfLAPFIntervalEntry 2 }



virtualIfLAPFIntervalPidMismatch OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        received PID field mismatch 
        encountered by a Virtual Interface in a
        particular 15-minute interval in the past 24 hours."
    ::= { virtualIfLAPFIntervalEntry 3 }


virtualIfLAPFIntervalDlciMismatch OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        received DLCI field mismatch  
        by a Virtual Interface in a
        particular 15-minute interval in the past 24 hours."
    ::= { virtualIfLAPFIntervalEntry 4 }

virtualIfLAPFIntervalMacRxFrames OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        frames received from LAN 
        by a Virtual Interface in a
        particular 15-minute interval in the past 24 hours."
    ::= { virtualIfLAPFIntervalEntry 5 }

virtualIfLAPFIntervalMacTxFrames OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        frames transmitted to LAN 
        encountered by a Virtual Interface in a
        particular 15-minute interval in the past 24 hours."
    ::= { virtualIfLAPFIntervalEntry 6 }


-- the Virtual Interface GFP Current Table

virtualIfGFPCurrentTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF VirtualIfGFPCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "The Virtual Interface GFP Current table."
     ::= { virtualIfStatistics 7 }

virtualIfGFPCurrentEntry OBJECT-TYPE
    SYNTAX  VirtualIfGFPCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "An entry in the Virtual Interface 
       GFP Current table."
    INDEX   { ifIndex  }
     ::= { virtualIfGFPCurrentTable 1 }

VirtualIfGFPCurrentEntry ::=
    SEQUENCE {
		 virtualIfGFPCurrentIdleFrameError  PerfCurrentCount,
		 virtualIfGFPCurrentCHecSbError     PerfCurrentCount,
         virtualIfGFPCurrentPtiMismatch     PerfCurrentCount,
		 virtualIfGFPCurrentExiMismatch     PerfCurrentCount,
		 virtualIfGFPCurrentUpiMismatch     PerfCurrentCount,
		 virtualIfGFPCurrentTHecSbError     PerfCurrentCount,
		 virtualIfGFPCurrentTHecMbError     PerfCurrentCount,
         virtualIfGFPCurrentCidMismatch     PerfCurrentCount,
         virtualIfGFPCurrentEHecSbError     PerfCurrentCount,
         virtualIfGFPCurrentEHecMbError     PerfCurrentCount
    }
								
virtualIfGFPCurrentIdleFrameError OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        received  GFP IDLE frames that are 
        detected to be in error,
        encountered by a Virtual Interface 
        in the current 15-minute interval."
     ::= { virtualIfGFPCurrentEntry 1}

virtualIfGFPCurrentCHecSbError OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        received GFP frames that are detected to have 
        single-bit errors in the Core 
        header (i.e. cHEC field) only, 
        encountered by a Virtual Interface 
        in the current 15-minute interval."
    ::= { virtualIfGFPCurrentEntry 2 }

virtualIfGFPCurrentPtiMismatch OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        rreceived GFP frames that are detected with 
        a mismatch on the PTI field 
        (i.e. value of PTI is not equal to 
        Client Data or Management frame),
        encountered by a Virtual Interface 
        in the current 15-minute interval."
    ::= { virtualIfGFPCurrentEntry 3 }


virtualIfGFPCurrentExiMismatch OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        received GFP frames that are detected with 
        a mismatch on the EXI field 
        (i.e. value of EXI is not equal 
        to NULL or LINEAR modes), 
        encountered by a Virtual Interface 
        in the current 15-minute interval."
    ::= { virtualIfGFPCurrentEntry 4 }


virtualIfGFPCurrentUpiMismatch OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        received GFP frames that are detected with a 
        mismatch on the UPI field
        (i.e. value of EXI is not equal to 00000001),
        encountered by a Virtual Interface               
        in the current 15-minute interval."
    ::= { virtualIfGFPCurrentEntry 5 }


virtualIfGFPCurrentTHecSbError OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        received GFP frames that are detected 
        to only have single-bit errors in the Type header 
        (i.e. tHEC field),
        encountered by a Virtual Interface 
        in the current 15-minute interval."
    ::= { virtualIfGFPCurrentEntry 6 }


virtualIfGFPCurrentTHecMbError OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
       received GFP frames that are detected to 
       only have multi-bit errors in the 
       Type header (i.e. tHEC field),        
       encountered by a Virtual Interface 
        in the current 15-minute interval."
    ::= { virtualIfGFPCurrentEntry 7 }

virtualIfGFPCurrentCidMismatch OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
       received GFP frames that are detected to have a 
       mismatch/unsupported value in the CID field only,  
       encountered by a Virtual Interface 
       in the current 15-minute interval."
    ::= { virtualIfGFPCurrentEntry 8 }

virtualIfGFPCurrentEHecSbError OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        received  GFP frames that are detected 
        to only have single-bit errors 
        in the Extension header (i.e. eHEC field), 
        encountered by a Virtual Interface 
        in the current 15-minute interval."
    ::= { virtualIfGFPCurrentEntry 9 }

virtualIfGFPCurrentEHecMbError OBJECT-TYPE
    SYNTAX  PerfCurrentCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        received GFP frames that are detected to only 
        have single-bit errors in the 
        Extension header (i.e. eHEC field), 
        encountered by a Virtual Interface 
        in the current 15-minute interval."
    ::= { virtualIfGFPCurrentEntry 10 }


-- the Virtual Interface GFP Interval Table

-- The Virtual Interface GFP Interval Table
-- contains various statistics collected  over a maximum
-- of the previous 24 hours of operation.  
-- The past 24 hours may be broken into 96 
-- completed 15 minute intervals.

virtualIfGFPIntervalTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF VirtualIfGFPIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "The Virtual Interface GFP Interval table."
     ::= { virtualIfStatistics 8 }

virtualIfGFPIntervalEntry OBJECT-TYPE
    SYNTAX  VirtualIfGFPIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "An entry in the Virtual Interface 
       GFP Interval table."
    INDEX   { ifIndex, virtualIfIntervalNumber }
     ::= { virtualIfGFPIntervalTable 1 }

VirtualIfGFPIntervalEntry ::=
    SEQUENCE {
     	  virtualIfGFPIntervalIdleFrameError	  PerfIntervalCount,
     	  virtualIfGFPIntervalCHecSbError	      PerfIntervalCount,
     	  virtualIfGFPIntervalPtiMismatch	      PerfIntervalCount,
     	  virtualIfGFPIntervalExiMismatch	      PerfIntervalCount,
     	  virtualIfGFPIntervalUpiMismatch	      PerfIntervalCount,
     	  virtualIfGFPIntervalTHecSbError	      PerfIntervalCount,
     	  virtualIfGFPIntervalTHecMbError	      PerfIntervalCount,
     	  virtualIfGFPIntervalCidMismatch	      PerfIntervalCount,
     	  virtualIfGFPIntervalEHecSbError	      PerfIntervalCount,
     	  virtualIfGFPIntervalEHecMbError	      PerfIntervalCount
     	      }

virtualIfGFPIntervalIdleFrameError OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        received  GFP IDLE frames that are detected to be in error,
        encountered by a Virtual Interface in a
        particular 15-minute interval in the past 24 hours."
    ::= { virtualIfGFPIntervalEntry 1 }

virtualIfGFPIntervalCHecSbError OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        received GFP frames that are detected to have 
        single-bit errors in the Core header (i.e. cHEC field) only, 
        encountered by a Virtual Interface in a
        particular 15-minute interval in the past 24 hours."
    ::= { virtualIfGFPIntervalEntry 2 }

virtualIfGFPIntervalPtiMismatch OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        rreceived GFP frames that are detected with 
        a mismatch on the PTI field (i.e. value of PTI 
        is not equal to Client Data or Management frame),
        encountered by a Virtual Interface in a
        particular 15-minute interval in the past 24 hours."
    ::= { virtualIfGFPIntervalEntry 3 }

virtualIfGFPIntervalExiMismatch OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        received GFP frames that are detected with 
        a mismatch on the EXI field (i.e. value of EXI is not 
        equal  to NULL or LINEAR modes), 		        
        encountered by a Virtual Interface in a
        particular 15-minute interval in the past 24 hours."
    ::= { virtualIfGFPIntervalEntry 4 }

virtualIfGFPIntervalUpiMismatch OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        received GFP frames that are detected with a 
        mismatch on the UPI field (i.e. value of EXI 
        is not equal to 00000001),
         encountered by a Virtual Interface in a
        particular 15-minute interval in the past 24 hours."
    ::= { virtualIfGFPIntervalEntry 5 }

virtualIfGFPIntervalTHecSbError OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        received GFP frames that are detected to only have
         single-bit errors in the Type header (i.e. tHEC field),
        encountered by a Virtual Interface in a
        particular 15-minute interval in the past 24 hours."
    ::= { virtualIfGFPIntervalEntry 6 }

virtualIfGFPIntervalTHecMbError OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated withthe number of
       received GFP frames that are detected to only have
       multi-bit errors in the Type header (i.e. tHEC field), 
       encountered by a Virtual Interface in a
       particular 15-minute interval in the past 24 hours."
    ::= { virtualIfGFPIntervalEntry 7 }

virtualIfGFPIntervalCidMismatch OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with  the number of
       received GFP frames that are detected to have a 
       mismatch/unsupported value in the CID field only,
       encountered by a Virtual Interface in a
       particular 15-minute interval in the past 24 hours."
    ::= { virtualIfGFPIntervalEntry 8 }

virtualIfGFPIntervalEHecSbError OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the number of
        received  GFP frames that are detected 
        to only have single-bit errors 
        in the Extension header (i.e. eHEC field),         
        encountered by a Virtual Interface in a
        particular 15-minute interval in the past 24 hours."
    ::= { virtualIfGFPIntervalEntry 9 }

virtualIfGFPIntervalEHecMbError OBJECT-TYPE
    SYNTAX  PerfIntervalCount
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "This counter is associated with the the number of
        received GFP frames that are detected to only  have
        multi-bit errors in the  Extension header (i.e. eHEC field),
        encountered by a Virtual Interface in a
        particular 15-minute interval in the past 24 hours."
    ::= { virtualIfGFPIntervalEntry 10 }



prtSonetConfig  OBJECT IDENTIFIER  ::=  {sonetInterface 2}

prtSonetGen  	OBJECT IDENTIFIER  ::=  {prtSonetConfig 1}

prtSonetGenTable OBJECT-TYPE
     SYNTAX  SEQUENCE OF PrtSonetGenEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
     "Sonet/SDH general port configuration table."
     ::= { prtSonetGen 1}
   
prtSonetGenEntry   OBJECT-TYPE
     SYNTAX  PrtSonetGenEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
     " An entry in the Sonet/SDH general port configuration table."
     INDEX { prtSonetGenCnfgIdx, prtSonetGenIdx }
     ::= { prtSonetGenTable 1}

PrtSonetGenEntry ::=
     SEQUENCE {
     prtSonetGenCnfgIdx
     Integer32,
     prtSonetGenIdx
     Integer32,
     prtSonetGenSdThreshold
     INTEGER,
     prtSonetGenEedThreshold
     INTEGER,
	  prtSonetGenBerEnable
     INTEGER

     }
 
prtSonetGenCnfgIdx OBJECT-TYPE
     SYNTAX  Integer32 (1..255)
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
     "This object indicates the Idx of the Config being accessed.
      Idx of 255 relates to the Temporary (Scratch) Config.
      For products that support several configurations, Set can be performed
      only to the Temporary Config (=255). "
     ::= { prtSonetGenEntry 1}

prtSonetGenIdx OBJECT-TYPE
     SYNTAX  Integer32
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
     "This object indicates a unique  port or interface number.
	 For numbering, see product's spec.
     For some products, the numbering can equal ifIndex."
     ::= { prtSonetGenEntry 2}

prtSonetGenSdThreshold OBJECT-TYPE
     SYNTAX  INTEGER {
     notApplicable(1),
     n3           (3),
     n4           (4),  
     n5           (5),
     n6			  (6),
     n7			  (7),
     n8			  (8),
     n9			  (9)   
     }
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
     "SD=Signal Degraded Threshold. Units: [10E-].
	  The threshold is 10E-x relative to the frequency of the data flow.
	  x=3, 4, 5, 6, 7, 8, 9.
      n3= 10E-3
      n4= 10E-4
      n5= 10E-5
      n6= 10E-6
      n7= 10E-7
      n8= 10E-8
      n9= 10E-9  ."
     ::= { prtSonetGenEntry 3 }

prtSonetGenEedThreshold OBJECT-TYPE
     SYNTAX  INTEGER {
     notApplicable(1),
	 n3			  (3),
	 n4			  (4),
	 n5			  (5),
     n6           (6),
     n7           (7),  
     n8           (8),
     n9           (9)    
     }
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
     "EED=Excessive Error Defect Threshold. Units: [10E-].
	  The threshold is 10E-x relative to the frequency of the data flow.
	  x=3, 4, 5, 6, 7, 8, 9.
      n3= 10E-3
      n4= 10E-4
      n5= 10E-5
      n6= 10E-6
      n7= 10E-7
      n8= 10E-8
      n9= 10E-9 ."
     ::= { prtSonetGenEntry 4 }

prtSonetGenBerEnable OBJECT-TYPE
     SYNTAX  INTEGER {
     notApplicable(1),
	 disable      (2),
     enable       (3)    
     }
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
      "Controls the activation of the Line Ber (Bit Error Rate), means whether 
       SD and EED threshold parameters will be enabled."
      ::= { prtSonetGenEntry 5 }




--STM-1 ports

prtSonetStm1  	OBJECT IDENTIFIER  ::=  {prtSonetConfig 2}


prtSonetStm1Table OBJECT-TYPE
     SYNTAX  SEQUENCE OF PrtSonetStm1Entry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
     "Sonet/SDH STM-1 port configuration table."
     ::= { prtSonetStm1 1}
   
prtSonetStm1Entry   OBJECT-TYPE
     SYNTAX  PrtSonetStm1Entry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
     " An entry in the Sonet/SDH STM-1 port configuration table."
     INDEX { prtSonetStm1CnfgIdx, prtSonetStm1Idx }
     ::= { prtSonetStm1Table 1}

PrtSonetStm1Entry ::=
     SEQUENCE {
     prtSonetStm1CnfgIdx
     Integer32,
     prtSonetStm1Idx
     Integer32,
     prtSonetStm1ClockSrc
     INTEGER,
     prtSonetStm1DccMode
     INTEGER,
	 prtSonetStm1RoutingProt
	 INTEGER,
	 prtSonetStm1MngProt
	 INTEGER,
	 prtSonetStm1OperationalMode
	 INTEGER,	  
     prtSonetStm1VoiceChannel 
     INTEGER	 
	 }
 
prtSonetStm1CnfgIdx OBJECT-TYPE
     SYNTAX  Integer32 (1..255)
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
     "This object indicates the Idx of the Config being accessed.
      Idx of 255 relates to the Temporary (Scratch) Config.
      For products that support several configurations, Set can be performed
      only to the Temporary Config (=255). "
     ::= { prtSonetStm1Entry 1}

prtSonetStm1Idx OBJECT-TYPE
     SYNTAX  Integer32
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
     "This object indicates a unique  port or interface number.
	 For numbering, see product's spec.
     For some products, the numbering can equal ifIndex."
     ::= { prtSonetStm1Entry 2}

prtSonetStm1ClockSrc OBJECT-TYPE
     SYNTAX  INTEGER {
     notApplicable(1),
     internal     (2),
     lbt          (3)
     }
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
     "Clock Source of the STM-1 port.
      lbt = Loop Back Timing."
     ::= { prtSonetStm1Entry 3 }

prtSonetStm1DccMode OBJECT-TYPE
     SYNTAX  INTEGER {
     notApplicable(1),
     none         (2),
     d1ToD3       (3),  
     d4ToD12      (4),
     d1           (5),
     d2           (6),
     d3           (7),
     d4           (8),     
     d5           (9),     
     d6           (10),     
     d7           (11),     
     d8           (12),     
     d9           (13),     
     d10          (14),     
     d11          (15),
     d12          (16)        
     }
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
     "DCC Mode. DCC=Data Communication Channel.
	  d1ToD3 = D1-D3  bytes are used (RS=Regeneration Section).
	  d4ToD12= D4-D12 bytes are used (MS=Multiplexing Section).
	  d1.... d12 enable user to select single DCC byte "
     ::= { prtSonetStm1Entry 4 }

prtSonetStm1RoutingProt OBJECT-TYPE
     SYNTAX  INTEGER {
      notApplicable (1),
      none          (2),  
      proprietary   (3),
	  rip2          (4)
     }
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
     "Routing Protocol."
     ::= { prtSonetStm1Entry 5 }

prtSonetStm1MngProt OBJECT-TYPE
     SYNTAX  INTEGER {
      notApplicable (1),
      -- none (2)
      proprietary   (3),  
      -- rip2  (4)
      ppp           (5),
	  frameRelay    (6)
     }
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
     "Management Protocol over DCC:  Proprietary, PPP or Frame Relay."
     ::= { prtSonetStm1Entry 6 }

prtSonetStm1OperationalMode OBJECT-TYPE
     SYNTAX  INTEGER {
      notApplicable    (1),
      terminal         (2),
      linear           (3),  
      linearProtection (4)
     }
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
     "Operational Mode.
      linear - cannot be selected when there is Redundancy between the
               STM-1 ports."
     ::= { prtSonetStm1Entry 7 }

prtSonetStm1VoiceChannel  OBJECT-TYPE
     SYNTAX  INTEGER {
      notApplicable (1),
      none   (2),
      e1Byte (3),
      e2Byte (4)  
     }
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
     "This parameter enable user to select whether
      voice channel will be transferred using E1 byte, E2 Byte, or not at all."
     ::= { prtSonetStm1Entry 8 }

  
--SONET/SDH VC-3, VC-4 and VC-12 ports parameters

prtSonetVc  	OBJECT IDENTIFIER  ::=  {prtSonetConfig 3}


prtSonetVcTable OBJECT-TYPE
     SYNTAX  SEQUENCE OF PrtSonetVcEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
     "Sonet/SDH VC port configuration table."
     ::= { prtSonetVc 1}
   
prtSonetVcEntry   OBJECT-TYPE
     SYNTAX  PrtSonetVcEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
     " An entry in the Sonet/SDH VC port configuration table."
     INDEX { prtSonetVcCnfgIdx, prtSonetVcIdx }
     ::= { prtSonetVcTable 1}

PrtSonetVcEntry ::=
     SEQUENCE {
     prtSonetVcCnfgIdx
     Integer32,
     prtSonetVcIdx
     Integer32,
     prtSonetVcJTxPathTraceEnable
     INTEGER,
     prtSonetVcJRxPathTraceEnable
     INTEGER,
	 prtSonetVcJPathTrace
	 DisplayString,
	 prtSonetVcConnect
	 INTEGER
     }
 
prtSonetVcCnfgIdx OBJECT-TYPE
     SYNTAX  Integer32 (1..255)
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
     "This object indicates the Idx of the Config being accessed.
      Idx of 255 relates to the Temporary (Scratch) Config.
      For products that support several configurations, Set can be performed
      only to the Temporary Config (=255). "
     ::= { prtSonetVcEntry 1}

prtSonetVcIdx OBJECT-TYPE
     SYNTAX  Integer32
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
     "This object indicates a unique  port or interface number.
	 For numbering, see product's spec.
     For some products, the numbering can equal ifIndex."
     ::= { prtSonetVcEntry 2}

prtSonetVcJTxPathTraceEnable OBJECT-TYPE
     SYNTAX  INTEGER {
     notApplicable(1),
     disable      (2),
	 enable       (3)
     }
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
     "Enable/Disable Transmitting Jy Path Trace. y=1, 2:
      J1 - for VC-4  layer
      J2 - for VC-12 layer."
     ::= { prtSonetVcEntry 3 }

prtSonetVcJRxPathTraceEnable OBJECT-TYPE
     SYNTAX  INTEGER {
     notApplicable(1),
     disable      (2),
	 enable       (3)
     }
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
     "Enable/Disable checking Jy Path Trace. y=1, 2:
      J1 - for VC-4  layer
      J2 - for VC-12 layer."
     ::= { prtSonetVcEntry 4 }

prtSonetVcJPathTrace OBJECT-TYPE
     SYNTAX  DisplayString (SIZE(0..16))
     MAX-ACCESS  read-write
     STATUS  current
     DESCRIPTION
     "Jy Path Trace. y=1, 2:
      J1 - for VC-4  layer
      J2 - for VC-12 layer.
      This object is applicable only if one of the previous 2 objects is 'enable'."
     ::= { prtSonetVcEntry 5 }

prtSonetVcConnect  OBJECT-TYPE
      SYNTAX  INTEGER
      {
      notApplicable (1),
	  no (2),
	  yes (3)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "Connect VCn (n - 11,12,2,3,4) port (yes/no)." 
     ::= { prtSonetVcEntry 6 }



--TU-12 (within VC-4) Connect Table

prtSonetTuTable  OBJECT-TYPE
     SYNTAX SEQUENCE OF PrtSonetTuEntry
     MAX-ACCESS not-accessible
     STATUS  current
     DESCRIPTION
      "The write operation into the Table's Objects is valid only
       for the TmpCnfg entry (Scratch)."
  ::= { prtSonetVc 2}

prtSonetTuEntry OBJECT-TYPE
      SYNTAX PrtSonetTuEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {prtSonetTuCnfgIdx, prtSonetTuPrtIdx, prtSonetTuIdx, prtSonetTuConPrtIdx }
      ::= { prtSonetTuTable 1}

PrtSonetTuEntry ::=
      SEQUENCE {
      prtSonetTuCnfgIdx        Integer32,
      prtSonetTuPrtIdx         Integer32,
      prtSonetTuIdx            Integer32,
      prtSonetTuConPrtIdx      Integer32,
      prtSonetTuType           INTEGER,
      prtSonetTuMode           INTEGER,
	  prtSonetTuRowStatus      RowStatus
      }

prtSonetTuCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32  (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates the Idx of the Config being accessed.
      Idx of 255 relates to the Temporary (Scratch) Config.
      For products that support several configurations, Set can be performed
      only to the Temporary Config (=255). "
      ::= { prtSonetTuEntry 1}

prtSonetTuPrtIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates a unique  port or interface number.
	  For port numbering, see product's spec.
      For some products, the numbering can equal ifIndex."
      ::= { prtSonetTuEntry 2}

prtSonetTuIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates a unique TU (Tributary Unit) within VC-4.
	   The valid TUs are 1..63."
      ::= { prtSonetTuEntry 3}

prtSonetTuConPrtIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates the connected port, when prtSonetTuType=connect.
	   For port numbering, see product's spec.
       For some products, the numbering can equal ifIndex.
       notApplicable - will be indicated as 100."
      ::= {prtSonetTuEntry 4}

prtSonetTuType  OBJECT-TYPE
      SYNTAX  INTEGER
      {
      connect (2),
	  bypass  (3)
      }
      MAX-ACCESS  read-create
      STATUS  current
      DESCRIPTION
      "The type of TU (Tributary Unit). 
       connect - connected to one of the E1 ports.
	   bypass  - bypassed to the other VC4 port.
       TUs that are not connected or bypassed, will not exist in this table." 
      ::= { prtSonetTuEntry 5}

prtSonetTuMode  OBJECT-TYPE
      SYNTAX  INTEGER
      {
      notApplicable(1),
      addAndDrop   (2),
      add          (3)
      }
      MAX-ACCESS  read-create
      STATUS  current
      DESCRIPTION
      "TU Mode of connection. 
       addAndDrop    - Add & Drop
       add           - Add (TU receives from the E1 ports)." 
      ::= { prtSonetTuEntry 6}

prtSonetTuRowStatus OBJECT-TYPE
      SYNTAX RowStatus 
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
      "Creation/Deletion of rows in the table."
      ::= { prtSonetTuEntry 7}


-- SDH Cross Connect Table
-- May be used also for SONET 

prtSonetXConnect  OBJECT IDENTIFIER  ::= {sonetInterface 3}

prtSonetXConnectTable  OBJECT-TYPE
     SYNTAX SEQUENCE OF PrtSonetXConnectEntry
     MAX-ACCESS not-accessible
     STATUS  current
     DESCRIPTION
      "The write operation into the Table's Objects is valid only
       for the TmpCnfg entry (Scratch)."
     ::= { prtSonetXConnect 1}

prtSonetXConnectEntry OBJECT-TYPE
      SYNTAX PrtSonetXConnectEntry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION  "An entry in table."
	  INDEX  { 
	         prtSonetXConnectCnfgIdx,
	         prtSonetXConnectPrtIdx,
	         prtSonetXConnectConPrtIdx,
	         prtSonetXConnectAUGIdx,
	         prtSonetXConnectTUG3Idx,
	         prtSonetXConnectTUG2Idx,
	         prtSonetXConnectTUnIdx
	         }
	      ::= { prtSonetXConnectTable 1}

PrtSonetXConnectEntry ::=
      SEQUENCE {
      prtSonetXConnectCnfgIdx        Integer32,
      prtSonetXConnectPrtIdx         Integer32,
	  prtSonetXConnectConPrtIdx      Integer32,
      prtSonetXConnectAUGIdx         Integer32,
      prtSonetXConnectTUG3Idx        Integer32,
      prtSonetXConnectTUG2Idx        Integer32,
      prtSonetXConnectTUnIdx         Integer32,
	  prtSonetXConnectRowStatus      RowStatus,
	  prtSonetXConnectDirection      INTEGER,
      prtSonetXConnectTuNumber       INTEGER
      }

prtSonetXConnectCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32  (1..255)
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates the Idx of the Config being accessed.
       Idx of 255 relates to the Temporary (Scratch) Config.
       For products that support several configurations, Set can be performed
       only to the Temporary Config (=255). "
      ::= { prtSonetXConnectEntry 1}

prtSonetXConnectPrtIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates a unique  port or interface number.
	   For port numbering, see product's spec.
       For some products, the numbering can equal ifIndex."
      ::= { prtSonetXConnectEntry 2}

prtSonetXConnectConPrtIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates the connected port. 
	   For port numbering, see product's spec.
       For some products, the numbering can equal ifIndex.
       notApplicable - will be indicated as 255."
      ::= {prtSonetXConnectEntry 3}


prtSonetXConnectAUGIdx OBJECT-TYPE
      SYNTAX  Integer32	
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates an  AUG (Administrative Unit Group) within STM-N.
	   The valid AUGs values are:
	   1 for STM-1
	   1...4 for STM-4,
	   1..16 for STM-16  and  
	   1..64 for STM-64  (STM-64)  
	   255 designates NA."
      ::= { prtSonetXConnectEntry 4}

prtSonetXConnectTUG3Idx OBJECT-TYPE
      SYNTAX  Integer32	
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates a  TUG-3 (Tributary Unit Group 3) within VC-4.
	   The valid TUG3s are values are 1..3. and 255 which designates NA "
      ::= { prtSonetXConnectEntry 5}

prtSonetXConnectTUG2Idx OBJECT-TYPE
      SYNTAX  Integer32	
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates a TUG2 (Tributary Unit Group 2 ) within VC-3.
	   The valid TUG2's values  are 1..7 and 255 which designates NA "
      ::= { prtSonetXConnectEntry 6}

prtSonetXConnectTUnIdx OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "This object indicates a TUn within TUG-2 or TUG-3
       (Tributary Unit n, where  n is 2, 12 or 11 within TUG-2,  
       or 3 within TUG-3)
       valid values are
	   1 for TU-2
	   1 for TU-3
	   1..4  for TU-11
	   1..3  for TU-12
	   255 designates NA" 
	   ::= { prtSonetXConnectEntry 7}


prtSonetXConnectRowStatus OBJECT-TYPE
      SYNTAX RowStatus 
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
      "Creation/Deletion of rows in the table."
      ::= { prtSonetXConnectEntry 8}


prtSonetXConnectDirection  OBJECT-TYPE
      SYNTAX  INTEGER
      {
      notApplicable(1),
      rx   (2),
      tx   (3),
	  both (4) 
      }
      MAX-ACCESS  read-create
      STATUS  current
      DESCRIPTION
      "TU direction of connection. 
      rx=Drop
      tx=Add
      both = Add & Drop "
      ::= { prtSonetXConnectEntry 9}
   
prtSonetXConnectTuNumber OBJECT-TYPE
      SYNTAX  INTEGER
      {
      notApplicable (1),
      tu2			(2),
      tu3           (3),
      tu11          (4),
	  tu12          (5)
      }
      MAX-ACCESS  read-create
      STATUS  current
      DESCRIPTION
       "This object indicates which TU is used in prtSonetXConnectTUnIdx "
      ::= { prtSonetXConnectEntry 10}


prtVcGroupCnfg  OBJECT IDENTIFIER  ::=  {prtSonetConfig 4}

vcGroupCnfgTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF VcGroupCnfgEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "The Virtual Concatenation Group configuration table."
     ::= { prtVcGroupCnfg 1 }

vcGroupCnfgEntry OBJECT-TYPE
    SYNTAX  VcGroupCnfgEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "An entry in the Virtual Concatenation Group 
        configuration table."
    INDEX   { vcGroupCnfgIdx,vcGroupCnfgNumber}
     ::= { vcGroupCnfgTable 1 }

VcGroupCnfgEntry ::=
    SEQUENCE {
             vcGroupCnfgIdx            Integer32,
             vcGroupCnfgNumber         Integer32,
             vcGroupCnfgRowStatus      RowStatus,
             vcGroupCnfgVcType         INTEGER,
             vcGroupCnfgNoOfVCs        Integer32,
             vcGroupCnfgLCAS           INTEGER,
             vcGroupCnfgEncapsulation  INTEGER,
		     vcGroupCnfgGroupIfIndex   InterfaceIndex,
		     vcGroupCnfgRip2           INTEGER,
			 vcGroupCnfgGfpChId		   Integer32
		      }

vcGroupCnfgIdx OBJECT-TYPE
     SYNTAX  Integer32 (1..255)
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
     "This object indicates the Idx of the Config being accessed.
      Idx of 255 relates to the Temporary (Scratch) Config.
      For products that support several configurations, Set can be performed
      only to the Temporary Config (=255). "
     ::= { vcGroupCnfgEntry 1}


vcGroupCnfgNumber OBJECT-TYPE
     SYNTAX    Integer32 
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
      "Virtual Concatenation Group Number.
       For FCD=155 up to four groups are defined
       valid values are 1..4"
      ::= { vcGroupCnfgEntry 2}

vcGroupCnfgRowStatus OBJECT-TYPE
      SYNTAX RowStatus 
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
      "Creation/Deletion of rows in the table."
      ::= { vcGroupCnfgEntry 3}

vcGroupCnfgVcType OBJECT-TYPE
      SYNTAX INTEGER
      {
       notApplicable  (1),
       vc12           (2), --SDH
       vc3            (3), --SDH
       vc4            (4), --SDH
       vt1dot5        (5), --SONET VT1.5
       sts1           (6)  --SONET STS-1 /SPE 
       }
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
      "User may select type of SDH Virtual Containers (VC) 
       (SONET Virtual Tributaries VT ) to be concatenated
       in this Virtual Concatenation Group.
       For SDH,  values 2,3,4 are valid.
       For SONET, values 5 and 6 are valid."
      ::= { vcGroupCnfgEntry 4}

vcGroupCnfgNoOfVCs  OBJECT-TYPE
     SYNTAX    Integer32 (0..84)
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
      "User may select number of  Virtual Containers (VC) 
       (SONET Virtual Tributaries VT ) to be concatenated
       in this Virtual Concatenation Group.
       Valid range for this number depends on 
       type VC selected by vcGroupCnfgVCType
       For SDH,  up to 63 VC12, or
                 up to 3  VC3,  or
                       1  VC4  are valid
       For SONET, up to 84 VT1.5 without LCAS, 
                  or 64 VT1.5 under  LCAS control.
                  or up tp 3 STS-1/SPE, or
                           1 STS-3"
      ::= { vcGroupCnfgEntry 5}

vcGroupCnfgLCAS OBJECT-TYPE
      SYNTAX INTEGER
      {
       notApplicable (1),
       lcasNotActive (2),
       lcasActive    (3)
       }
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
      "This object controls Link Capacity Adjustment 
      Scheme (LCAS)  activation."
      ::= { vcGroupCnfgEntry 6}

vcGroupCnfgEncapsulation OBJECT-TYPE
      SYNTAX INTEGER
      {
       notApplicable (1),
       laps          (2), -- Link access protocol S
       lapf          (3), -- Link access protocol F (Frame relay)
       gfp           (4)  -- Generic Framing Procedure
       }
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
      "This object enables user to select encapsulation method."
      ::= { vcGroupCnfgEntry 7}


vcGroupCnfgGroupIfIndex  OBJECT-TYPE
      SYNTAX InterfaceIndex
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The ifIndex assigend to this group."                              
      ::= { vcGroupCnfgEntry 8}

vcGroupCnfgRip2 OBJECT-TYPE
      SYNTAX INTEGER
      {
       notApplicable (1),
       no            (2),
       yes           (3)
       }
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
      "This object controls RIP 2.
      User may select to send RIP 2 message over 
      selected group or not"
      ::= { vcGroupCnfgEntry 9}


vcGroupCnfgGfpChId	OBJECT-TYPE	   
      SYNTAX    Integer32 (0..255)
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
      "Generic Framing Procedure (GFP) Channel ID, 
      Valid only when vcGroupCnfgEncapsulation = gfp (4)
      Valid values are 0x00 - oxFF  (hex) "
      ::= { vcGroupCnfgEntry 10}

  

vcgGfpMuxCnfgTable	OBJECT-TYPE
      SYNTAX  SEQUENCE OF VcgGfpMuxCnfgEntry
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
      "The Virtual Concatenation Group GFP Mux configuration table."
       ::= { prtVcGroupCnfg 2 }

-- This table defines multiplexing scheme for GFP mux of 
-- Virtual Concatenation Groups:
-- Primary group, Secondary group/s and bandwidth allocation   
-- to each group.

vcgGfpMuxCnfgEntry OBJECT-TYPE
      SYNTAX  VcgGfpMuxCnfgEntry
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
      "An entry in the Virtual Concatenation Group GFP Mux 
       configuration table."
      INDEX   { vcgGfpMuxCnfgIdx,vcgGfpMuxCnfgMuxNumber}
       ::= { vcgGfpMuxCnfgTable 1 }

VcgGfpMuxCnfgEntry ::=
    SEQUENCE {						 
 		      vcgGfpMuxCnfgIdx     Integer32,
			  vcgGfpMuxCnfgMuxNumber   Integer32,
 		      vcgGfpMuxCnfgRowStatus   RowStatus,
			  vcgGfpMuxCnfgMuxName     SnmpAdminString,
 		      vcgGfpMuxCnfgPrimeGroup  Integer32,
  		      vcgGfpMuxCnfgGrpBwAlloc OCTET STRING
 		      }

vcgGfpMuxCnfgIdx OBJECT-TYPE
      SYNTAX  Integer32 (1..255)
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
      "This object indicates the Index of the configuration being accessed.
       Index of 255 relates to the Temporary (Scratch) coninguration.
       For products that support several configurations, Set can be performed
       only to the Temporary Config (=255). "
      ::= { vcgGfpMuxCnfgEntry 1}

vcgGfpMuxCnfgMuxNumber OBJECT-TYPE
      SYNTAX    Integer32 
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
      "Virtual Concatenation Group GFP Mux Number.
       For FCD=155 up to 2 GFP muxes can be created."
      ::= { vcgGfpMuxCnfgEntry 2}
 
vcgGfpMuxCnfgRowStatus OBJECT-TYPE
      SYNTAX RowStatus 
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
      "Creation/Deletion of rows in the table."
      ::= { vcgGfpMuxCnfgEntry 3}

vcgGfpMuxCnfgMuxName  OBJECT-TYPE
      SYNTAX    SnmpAdminString 
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
      "Virtual Concatenation Group, GFP Mux name."
      ::= { vcgGfpMuxCnfgEntry 4}


vcgGfpMuxCnfgPrimeGroup OBJECT-TYPE
     SYNTAX  Integer32 
     MAX-ACCESS  read-create
     STATUS  current
     DESCRIPTION
     "Index of Virtual Concatenation Group used as 
      Primary for the GFP mux created 
      for FCD 155 four Virtual Concatenation Group are defined:
      1 -> Virtual Concatenation Group 1
	  2 -> Virtual Concatenation Group 2
      3 -> Virtual Concatenation Group 3
      4 -> Virtual Concatenation Group 4"
     ::= { vcgGfpMuxCnfgEntry 5}


vcgGfpMuxCnfgGrpBwAlloc OBJECT-TYPE
     SYNTAX  OCTET STRING 
     MAX-ACCESS  read-create
     STATUS  current
     DESCRIPTION
     "This object indicates the  allocated bandwidth (BW) to each 
     Virtual Concatenation Group (VCG).
     Each nibble indicates BW percentage, in 12.5% steps, 
     assigned to a group. 
     
     For FCD-155,  there are 4 VCGs. 
     One VCG is identified as primary group by vcGfpMuxConfPrimeGroup.
	 Other VCGs may be secondaries.
	 VCG with allocated BW value of zero does not belong to the GFPmux
	 defined by GFP Mux number.
	          ________________________________________
	         |     Octet 0       |     Octet 1       |  
             |Nibble 4   Nibble 3| Nibble 2| Nibble 1|
	   MSB   | 7 6 5 4 | 3 2 1 0 | 7 6 5 4 | 3 2 1 0 | LSB
	           VCG1        VCG2     VCG 3    VCG4
       Nibble value - BW Percentage
       (0...7)         (0 ...87.5%) 
      1   0001            12.5 %
      2   0010 		      25%
	  3   0011            37.5
	  .....
	  7   0111            87.5%
        
	  at least one nibble must be greater that zero. 
	  Sum of alloacted BW must be 100%.
	  Primary VCG BW must be greater than zero."
     ::= { vcgGfpMuxCnfgEntry 6}


-- END-- 
-- file :v:\doc\rdv\mib\ver495\atm\NtePrtCo.txt
-- 
-- *************************
-- file  : NtePrtConfg.txt
--
--Version:   1.0
--Date:      12.11.97
--By:        Ilana Schvetz
--File:      v:\doc\rdv\mib\ver495\atm\NtePrtConfg.txt 

--Last Update: 15-Feb-04 by Yig'al Hachmon (back to original 495)
-- Copyright 1997 RAD Data Communications, Ltd.
-- All Rights Reserved.

atmNte              OBJECT IDENTIFIER ::= { radAtm 3 }
atmNtePrt		    OBJECT IDENTIFIER ::= { atmNte 2 }
atmNtePrtConfig		OBJECT IDENTIFIER ::= { atmNtePrt 1 }

atmNteEvents OBJECT-IDENTITY
     STATUS  current
     DESCRIPTION
     "The events for RAD ATM products."
     ::= { atmNte 0 }

atmNteConfIfTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF AtmNteConfIfEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
              "The Physical interface configuration table."
              ::= { atmNtePrtConfig 1 }

          atmNteConfIfEntry OBJECT-TYPE
              SYNTAX  AtmNteConfIfEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
              "An entry in the Physical interface configuration table.
               The ifIndex is of the lowest physical layer."
              INDEX   { ifIndex}
              ::= { atmNteConfIfTable 1 }

          AtmNteConfIfEntry ::=
              SEQUENCE {
				atmConfIfTransmitClk
				      INTEGER,
				atmConfIfLoopback
				      INTEGER,
				atmConfIfFrameType
				      INTEGER,
				atmConfIfCardType
				      INTEGER,
				atmConfAtmIfVpiVciLimit
				      INTEGER,
				atmConfIfHwFeatures
				      INTEGER,
				atmConfIfOutputRate
				      Integer32,
				atmConfIfInputRate
				      Integer32,
				atmConfAlarmForwarding
				      INTEGER,
				atmConfIfAllocatedBw
					  Integer32,
				atmConfIfLowerVpi
					  Integer32,
				atmConfIfOamMode
					  INTEGER
					  }

          atmConfIfTransmitClk OBJECT-TYPE
              SYNTAX  INTEGER { internal(2), external(3), loopback(4), adaptive(5) }
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION
              "The transmit clock of the port."
              ::= { atmNteConfIfEntry 1 }

          atmConfIfLoopback OBJECT-TYPE
              SYNTAX  INTEGER { internal(2), external(3), disable(4) }
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION
              "Interface Loopback."
              ::= { atmNteConfIfEntry 2 }

          atmConfIfFrameType OBJECT-TYPE
              SYNTAX  INTEGER {  
              other        (1),
              sonet        (2),
			  sdh          (3),
			  direct       (4),
			  plcpInternal (5),
			  plcpExternal (6),
			  e3           (7),
			  ethCrcTrans  (8),	
			  ethCrcNotTrans          (9),
	          directNoScrmbling       (10),
	          plcpInternalNoScrmbling (11),
	          plcpExternalNoScrmbling (12)
	          }
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION
              "The frame type. Valid values for a 155M interface:
               sonet(2), sdh(3). Valid values for a T3 interface:
               direct(4), plcpInternal(5), plcpExternal(6), 
               directNoScrmbling(10), plcpInternalNoScrmbling(11),
               plcpExternalNoScrmbling(12). Valid values for Ethernet 
               interface: ethCrcTrans (8), ethCrcNotTrans(9). 
               (DS1 interfaces frame type is specified in the DSX1 mib)."
              ::= { atmNteConfIfEntry 3 }

          atmConfIfCardType OBJECT-TYPE
              SYNTAX  INTEGER {
		      notApplicable(1), 
		      sc13m-155(2),
		      st13s-155(3),
		      st13l-155(4),
		      utp-155(5),
		      cx-bnc-155(6),
		      e3(7),
		      t3(8),
			  e1(9),
		      e1-ltu(10),
		      fc13l-155(11),
		      fc13lh-155(12),
		      fc15lh-155(13),
		      fc13l-e3(14),
	          fc13lh-e3(15),
		      fc15lh-e3(16),
		      fc13l-t3(17),
		      fc13lh-t3(18),
		      fc15lh-t3(19)
              }			
         	  MAX-ACCESS  read-only
         	  STATUS  deprecated
         	  DESCRIPTION
         	          "The card type."
         	  ::= { atmNteConfIfEntry 4 }
				
         	  atmConfAtmIfVpiVciLimit OBJECT-TYPE
         	  SYNTAX  INTEGER { 
         	  bits15(2),
			  bits17(3)
			   }
         	  MAX-ACCESS  read-only
         	  STATUS  current
         	  DESCRIPTION
         	  "The limit on the sum of the VPI+VCI bits for this interface."
         	  ::= { atmNteConfIfEntry 5 }
				
              atmConfIfHwFeatures  OBJECT-TYPE
              SYNTAX  INTEGER { 
              disable(1),
			  enable(2)
			  }
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION
              "HW features command."
              ::= { atmNteConfIfEntry 6 }

              atmConfIfOutputRate  OBJECT-TYPE
              SYNTAX  Integer32
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION
              "This parameter indicates the output rate in cells/sec, which is 
              supported per port. Successfully setting this parameter 
              is dependent on all other ports values calculations, 
              which are described in the NMS SRS."
              ::= { atmNteConfIfEntry 7 }

              atmConfIfInputRate  OBJECT-TYPE
              SYNTAX  Integer32
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION
              "This parameter indicates the input rate in cells/sec, which is 
              supported per port. Successfully setting this parameter 
              is dependent on all other ports values calculations, 
              which are described in the NMS SRS."
              ::= { atmNteConfIfEntry 8 }

          atmConfAlarmForwarding OBJECT-TYPE
              SYNTAX  INTEGER { disable(2), enable(3) }
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION
              "Enables Path AIS Alarm forwarding upon a failure detection. The
			  following might be considered as a failure: LOS, LOF, LOC, SLM, 
			  LOP, Path AIS and Line AIS. 
              
              disable(2) -  will not forward an alarm upon a failure on this port.  
              
              enable(3) - will forward an alarm upon a failure on this port."
              ::= { atmNteConfIfEntry 9 }

		  atmConfIfAllocatedBw OBJECT-TYPE
			  SYNTAX  Integer32 
    		  MAX-ACCESS read-only
			  STATUS current
			  DESCRIPTION
			  	"Total VC Bandwidth Allocation."
			  ::= { atmNteConfIfEntry 10 }

		  atmConfIfLowerVpi OBJECT-TYPE
    		  SYNTAX  Integer32
 		      MAX-ACCESS  read-write
		      STATUS  current
		      DESCRIPTION
			    "The Lower possible VPI."
			  ::= { atmNteConfIfEntry 11 }
		  
		  atmConfIfOamMode OBJECT-TYPE
    		  SYNTAX  INTEGER {
              		--	intermediate(1),
              		segmentTermination(2),
              		endToEndTermination(3)
			  		-- vpEndToEndVcSegment(4)
              	}
 		      MAX-ACCESS  read-write
		      STATUS  current
		      DESCRIPTION
			    "OAM support Mode, which determines the
			     interface's location in a segment wise."
			  ::= { atmNteConfIfEntry 12 }
																	 
atmNteAlarmIfTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF AtmNteAlarmIfEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "The interface Alarm table."
              ::= { atmNtePrtConfig 2 }

          atmNteAlarmIfEntry OBJECT-TYPE
              SYNTAX  AtmNteAlarmIfEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "An entry in the interface Alarm table."
              INDEX   { ifIndex}
              ::= { atmNteAlarmIfTable 1 }

          AtmNteAlarmIfEntry ::=
              SEQUENCE {
				atmInterfaceActiveAlarms
				      Integer32,
				atmThresholdSectionBIP
				      Integer32,
				atmThresholdLineBIP
				      Integer32,
				atmThresholdLineFEBE
				      Integer32,
				atmThresholdPathBIP
				      Integer32,
				atmThresholdPathFEBE
				      Integer32,
				atmThresholdErroredCells
				      Integer32,
				atmThresholdLostCells
				      Integer32,
				atmThresholdMisinsertedCells
				      Integer32,
			    atmInterfaceAlarmStatus
				      INTEGER,
                atmInterfaceMaskAlarms
				      Integer32
              }

          atmInterfaceActiveAlarms OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "A Bit String of the active alarms on this interface.
					   An up bit (1) means there is an active alarm of this
					   type. A down bit (0) means there is no such alarm.
                       The meaning of the bits is as follows:
                       1 - LOS
                       2 - LOF
                       3 - Line AIS (SONET)/ PLCP LOF (DS3)
                       4 - LOP
                       5 - Path AIS
                       6 - SLM
                       7 - LCD
                       8 - Line RDI  (SONET)/ PLCP Yellow (DS3)
                       9 - Path RDI  (SONET)/ RDI (DS3)
					   10 - Section BIP (SONET)/ P1/P2 (DS3) > Threshold
					   11 -	Line BIP (SONET)/ PLCP BIP (DS3) > Threshold
					   12 - Line FEBE (SONET)/ PLCP FEBE (DS3) > Threshold
					   13 - Path BIP > Threshold
					   14 - Path FEBE > Threshold
					   15 - HW Failure
                       "
              ::= { atmNteAlarmIfEntry 1 }

          atmThresholdSectionBIP OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION
                      "When Section BIPs are greater than this threshold,
	an active alarm is raised. N/A for ds3/e3 interface."
              ::= { atmNteAlarmIfEntry 2 }

          atmThresholdLineBIP OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION
                      "When Line BIPs are greater than this threshold,
	an active alarm is raised. N/A for ds3/e3 interface."
              ::= { atmNteAlarmIfEntry 3 }

          atmThresholdLineFEBE OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION
                      "When Line FEBEs are greater than this threshold,
	an active alarm is raised. N/A for ds3/e3 interface."
              ::= { atmNteAlarmIfEntry 4 }

          atmThresholdPathBIP OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION
                      "When Path BIPs are greater than this threshold,
					   an active alarm is raised."
              ::= { atmNteAlarmIfEntry 5 }

          atmThresholdPathFEBE OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION
                      "When Path FEBEs are greater than this threshold,
					   an active alarm is raised."
              ::= { atmNteAlarmIfEntry 6 }

          atmThresholdErroredCells OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION
                      "When Errored Cells are greater than this threshold,
					   an active alarm is raised."
              ::= { atmNteAlarmIfEntry 7 }

          atmThresholdLostCells OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION
                      "When Lost Cells are greater than this threshold,
					   an active alarm is raised."
              ::= { atmNteAlarmIfEntry 8 }

          atmThresholdMisinsertedCells OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION
                      "When Misinserted Cells are greater than this threshold,
					   an active alarm is raised."
              ::= { atmNteAlarmIfEntry 9 }

 

          atmInterfaceAlarmStatus OBJECT-TYPE
              SYNTAX  INTEGER { off(2),
			                    on(3) }
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The variable is on(3) when there is any active alarm
                       on this interface."
              ::= { atmNteAlarmIfEntry 10 }

          atmInterfaceMaskAlarms OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION
                      "A Bit String of alarms mask on this interface.
					   An up bit (1) means that the respective alarm is masked.
					   A down bit (0) means no mask.
                       The mask is supported for the following alarms:
                       1 - LOS
                       "
              ::= { atmNteAlarmIfEntry 11 }


          atmNteConfVpTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF AtmNteConfVpEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "The ATM VP configuration table.
                       The table is an extension to the atmVplTable of
                       RFC-1695."
              ::= { atmNtePrtConfig 3 }

          atmNteConfVpEntry OBJECT-TYPE
              SYNTAX  AtmNteConfVpEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "An entry in the ATM VP configuration table.
                       ifIndex of the ATM layer."
              INDEX   { ifIndex, atmVplVpi }
              ::= { atmNteConfVpTable 1 }

          AtmNteConfVpEntry ::=
              SEQUENCE {
			atmConfVpPolicing            INTEGER,
			atmConfVpCCAdminStatus       INTEGER,
			atmConfVpLoopbackAdminStatus INTEGER,
			atmConfVpLoopbackSinkAddress OCTET STRING,
			atmConfVpCongestionControl   OCTET STRING,
			atmConfVpCCDirection         INTEGER,
            atmConfVpCreationTime        DateAndTime,
            atmConfVpOamSupport          INTEGER,
            atmConfVpCCOperStatus        INTEGER,
			atmConfVpLoopbackTraffic     INTEGER,
            atmConfVpLoopbackFailureInd	 INTEGER,
            atmConfVpLoopbackFailureThreshold	 Integer32,
			atmConfVpOamDirection         INTEGER
           }

 atmConfVpPolicing OBJECT-TYPE
              SYNTAX  INTEGER { 
                 none(1), 
                 police(2), 
                 monitor(3), 
                 shaping(4), 
                 policingAndShaping(5) 
              }
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION
                      "Policing method desired for this VPL."
              ::= { atmNteConfVpEntry 1 }

        atmConfVpCCAdminStatus OBJECT-TYPE
             SYNTAX INTEGER {
		            up    (2), 
            		down  (3), 
		            source(4),      -- agent send Oam CC cells 
		            sink  (5),      -- agent check received Oam CC cells
                    listenToActivationCells (6),
                    originateActivationCells(7)     
                            } 
             MAX-ACCESS read-write
             STATUS current
             DESCRIPTION
                     	"up(2) - Activate Continuity Check (CC).
                      	down(3) - Deactivate CC.
		                source(4)      - Activate OAM CC(Continuity Check) of local agent
                        			( start sending Oam cells to the remote side ).
      		            sink(5)          - Activate CC of remote agent ( start receiving Oam cells from
      		             				remote 	side ).
                     listenToActivationCells (6) - Passive listener till gets an activation request
                     originateActivationCells(7) - Sands Activation cell according to atmConfVcCCDirection."
             ::= {atmNteConfVpEntry 2}

	atmConfVpLoopbackAdminStatus OBJECT-TYPE
                    SYNTAX INTEGER {
		            up(2),
		            down(3),
		            llid(4),
		            segment(5),
		            endToEnd(6),
		            segmentLlid(7),
		            endToEndLlid(8)
	                } 
             		MAX-ACCESS read-write
             		STATUS current
             		DESCRIPTION
                        "up(2) - Start loopback OAM cells.
                         down(3) - Stop sending loopback OAM cells.
                   
                         For ace2002:
                         up(2)   - Transmitting LB cells with llid all ones 
                                   (i.e. FFFF..FF)
                         down(3) - Not transmitting LB cells. 
                         llid(4) - Transmitting LB cells with llid indicated 
                                    in the address field.
                         segment(5) - Transmitting Segment LB cells with llid
                                       all ones. 
                         endToEnd(6) - Transmitting End to End LB cells with llid
                                        all ones. 
                         segmentLlid(7) - Transmitting Segment LB cells with
                                           llid indicated in the address field.  
                         endToEndLlid(8) - Transmitting LB cells with llid
                                            indicated in the address field.  
                   
                         This parameter value might be in conflict with 
                         atmConfVpOamSupport value, since this parameter is for LB, 
                         while atmConfVpOamSupport is for any other OAM cells."                   
             ::= {atmNteConfVpEntry 3}

	atmConfVpLoopbackSinkAddress OBJECT-TYPE
             		SYNTAX OCTET STRING  (SIZE(0..20))
             		MAX-ACCESS read-write
             		STATUS current
             		DESCRIPTION
                    	 "Destination address.
                    	 For ace101: 2 bytes are used.
                    	 For ace2002: 16 bytes are used."
             ::= {atmNteConfVpEntry 4}

	atmConfVpCongestionControl OBJECT-TYPE
             		SYNTAX OCTET STRING
             		MAX-ACCESS read-write
             		STATUS current
             		DESCRIPTION
                    	 "Each bit indicates a selection of one option 
                               as the following description.  All combinations 
                               are possible and legal.
                               The codes are: 
                               1 - EPD
                               2 - CLP
                               4 - EFCI"
             ::= {atmNteConfVpEntry 5}

     atmConfVpCCDirection OBJECT-TYPE
             SYNTAX  INTEGER {
		            both  (2), 
		            source(4),      
		            sink  (5)     
                            } 
             MAX-ACCESS read-write
             STATUS current
             DESCRIPTION
                     	"both(2) - Agent send OAM CC cells and check received OAM CC cells
                        source(4)- Agent send OAM CC cells.
      		            sink(5)  - Agent checks received OAM CC cells."    
             ::= {atmNteConfVpEntry 6}

     atmConfVpCreationTime OBJECT-TYPE
         SYNTAX   DateAndTime
         MAX-ACCESS   read-only
         STATUS   current
         DESCRIPTION
            "A date-time in which the VP was created."
         ::= { atmNteConfVpEntry 7 }

     atmConfVpOamSupport OBJECT-TYPE
               SYNTAX  INTEGER {
                          intermediate(1),
                          segmentTermination(2),
                          endToEndTermination(3)
                      }
               MAX-ACCESS  read-write
               STATUS  current
               DESCRIPTION
               "OAM support  mode, which determines the device location
                in a segment wise."
               ::= { atmNteConfVpEntry 8 }


	atmConfVpCCOperStatus OBJECT-TYPE
             SYNTAX INTEGER {
		             initial (1),
		             source(4),       
		             sink  (5),
					 both  (8),
		 			 timeout (9), 
				     denied (10),
					 conflict (11),
					 manual (12)
                            } 
             MAX-ACCESS read-only
             STATUS current
             DESCRIPTION
                     	"
		                initial(1) - The CC activation process is not started.
		                source(4) - Agent sends OAM CC cells.
      		            sink(5)   - Agent checks received OAM CC cells.
						both (8) - OAM CC of local and remote agents activation.
		                timeout (9) - Timeout occured on receiving answer from
                                      the remote agent.
		                denied  (10) - CC activation process rejected by remote agent.
		                conflict (11) - local and remote sides requested activation
                                      simultaneously.
				        manual (12) - OAM CC of local agent activated manually.
                        "
             ::= {atmNteConfVpEntry 9}

	atmConfVpLoopbackTraffic OBJECT-TYPE
             		SYNTAX INTEGER { off(2), on(3) } 
             		MAX-ACCESS read-write
             		STATUS current
             		DESCRIPTION
                    	 "This parameter has both command and status meanings: 
                    	 off(2) - Set to 'Off' will Stop traffic loop. Getting this
                    	          value means that the loop is not running.
                      	 on (3) - Set to 'On' will start traffic loop. Getting 
                      	          this value means that the loop is currently running."
             ::= {atmNteConfVpEntry 10}

	atmConfVpLoopbackFailureInd OBJECT-TYPE
             		SYNTAX INTEGER { 
             		disabled(2), 
             		segmentAis(3),
             		segmentRdi(4),
             		segmentAisAndRdi(5),
             		endToEndAis(6),
             		endToEndRdi(7),
             		endToEndAisAndRdi(8)
             		} 
             		MAX-ACCESS read-write
             		STATUS current
             		DESCRIPTION
    "This object allows user to define the Indication that will be created upon 
     a LB cell failure.
     disabled(2) - no indication will be created.
     segmentAis(3) - will cause Tx of a segment AIS.
     segmentRdi(4) - will cause Tx of a segment RDI.
     segmentAisAndRdi(5) - will cause Tx of a segment AIS & RDI. 
     endToEndAis(6) - will cause Tx of an End to End AIS.
     endToEndRdi(7)	- will cause Tx of an End to End RDI.
     endToEndAisAndRdi(8) - will cause Tx of an End to End AIS & RDI.
     Default: disabled(2)."
             ::= {atmNteConfVpEntry 11}

	atmConfVpLoopbackFailureThreshold OBJECT-TYPE
             		SYNTAX Integer32  
             		MAX-ACCESS read-write
             		STATUS current
             		DESCRIPTION
    "The number of the LB failures before starting transmission of the 
    Indication defined by atmConfVcLoopbackFailureInd.
    Range: 1..16. Default: 1."
             ::= {atmNteConfVpEntry 12}

     atmConfVpOamDirection OBJECT-TYPE
             SYNTAX  INTEGER {
		            notApplicable  (1), 
		            downStream     (2),      
		            upStream       (3)     
                            } 
             MAX-ACCESS read-write
             STATUS current
             DESCRIPTION
     "The direction of OAM cell insertion.
	 downStream(2) - The OAM cell will be inserted in downStream.     
	 upStream(3)   - The OAM cell will be inserted in upStream."    
             ::= {atmNteConfVpEntry 13}


--Alarm Table
          atmNteAlarmVpTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF AtmNteAlarmVpEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "The ATM VP Alarm table."
              ::= { atmNtePrtConfig 5 }

          atmNteAlarmVpEntry OBJECT-TYPE
              SYNTAX  AtmNteAlarmVpEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "An entry in the ATM VP Alarm table.
                       ifIndex of the ATM layer."
              INDEX   { ifIndex, atmNteVpAlarmVpi}
              ::= { atmNteAlarmVpTable 1 }

          AtmNteAlarmVpEntry ::=
              SEQUENCE {
			    atmNteVpAlarmVpi
				      Integer32,
			    atmNteVpActiveAlarms
				      Integer32
              }

          atmNteVpAlarmVpi OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The VPI on which there is an active alarm."
              ::= { atmNteAlarmVpEntry 1 }

          atmNteVpActiveAlarms OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "A Bit String of the active alarms on this VP.
					   An up bit (1) means there is an active alarm of this
					   type. A down bit (0) means there is no such alarm.
                       The meaning of the bits is as follows:
                       1 -	VP AIS
                       2 -	VP Loss Of Continuity
					   3 -  VP RDI Reception
					   4 -	VP Errored Cells > Threshold 
					   5 -	VP Lost Cells > Threshold 
					   6 -	VP Misinserted Cells > Threshold
					   9 -  VP Loopback Failure
                       "
              ::= { atmNteAlarmVpEntry 2 }

          atmNteAlarmVcTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF AtmNteAlarmVcEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "The ATM VC Alarm table."
              ::= { atmNtePrtConfig 6 }

          atmNteAlarmVcEntry OBJECT-TYPE
              SYNTAX  AtmNteAlarmVcEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "An entry in the ATM VC Alarm table.
                       ifIndex of the ATM layer."
              INDEX   { ifIndex, atmNteVcAlarmVpi, atmNteVcAlarmVci}
              ::= { atmNteAlarmVcTable 1 }

          AtmNteAlarmVcEntry ::=
              SEQUENCE {
			    atmNteVcAlarmVpi
				      Integer32,
			    atmNteVcAlarmVci
				      Integer32,
			    atmNteVcActiveAlarms
				      Integer32
              }

          atmNteVcAlarmVpi OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The VPI of the VC on which there is an active alarm."
              ::= { atmNteAlarmVcEntry 1 }

          atmNteVcAlarmVci OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The VCI of the VC on which there is an active alarm."
              ::= { atmNteAlarmVcEntry 2 }

atmNteVcActiveAlarms OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "A Bit String of the active alarms on this VC.
					   An up bit (1) means there is an active alarm of this
					   type. A down bit (0) means there is no such alarm.
                       The meaning of the bits is as follows:
                       1 -	VC AIS
                       2 -	VC Loss Of Continuity
					   3 -  VC RDI
					   4 -	VC Errored Cells > Threshold 
					   5 -	VC Lost Cells > Threshold 
					   6 -	VC Misinserted Cells > Threshold
					   7 - 	Tx VC AIS
					   8 - 	Tx VC RDI
					   9 -  VC Loopback Failure
                       "
              ::= { atmNteAlarmVcEntry 3 }

-- 
-- file :v:\doc\rdv\mib\ver495\atm\confVcTa.txt
-- 
-- file  : ConfVcTable.txt
--
--Version:   1.0
--Date:      12.11.97
--By:        Ilana Schvetz
--File:      v:\doc\rdv\mib\ver495\atm\ConfVcTable.txt 
 
--Last Update: 15-Dec-02 by Shay Harari.

-- *******************************************************
--          Configuration Vc Table
-- *******************************************************

--atmNte	 OBJECT IDENTIFIER ::= { radAtm 3 }
--atmNtePrt		OBJECT IDENTIFIER ::= { atmNte 2 }
--atmNtePrtConfig		OBJECT IDENTIFIER ::= { atmNtePrt 1 }


atmNteConfVcTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF AtmNteConfVcEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "The ATM VC configuration table.
                       The table is an extension to the atmVclTable of
                       RFC-1695."
              ::= { atmNtePrtConfig 4 }

          atmNteConfVcEntry OBJECT-TYPE
              SYNTAX  AtmNteConfVcEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "An entry in the ATM VC configuration table.
                       ifIndex of the ATM layer."
              INDEX   { ifIndex , atmVclVpi, atmVclVci}
              ::= { atmNteConfVcTable 1 }

          AtmNteConfVcEntry ::=
              SEQUENCE {
				atmConfVcPolicing            INTEGER,
				atmConfVcCCAdminStatus       INTEGER,
				atmConfVcLoopbackAdminStatus INTEGER,
			    atmConfVcLoopbackSinkAddress OCTET STRING,
			    atmConfVcCongestionControl   OCTET STRING,
                atmConfVcCCDirection		 INTEGER,
                atmConfVcCreationTime        DateAndTime,
                atmConfVcOamSupport          INTEGER,
				atmConfVcCCActivationCtrl    INTEGER,
				atmConfVcCCOperStatus        INTEGER,
				atmConfVcLoopbackTraffic     INTEGER,
				atmConfVcLoopbackFailureInd	 INTEGER,
				atmConfVcLoopbackFailureThreshold	 Integer32,
			    atmConfVcOamDirection        INTEGER,
				atmConfVcName				 DisplayString,
				atmConfVcConnected			 INTEGER
              }

          atmConfVcPolicing OBJECT-TYPE
              SYNTAX  INTEGER { 
		         none(1),
		         police(2),
		         monitor(3),
		         shaping(4),
                 policingAndShaping(5), 
		         notApplicable(255)
	          }
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION
              "Policing method desired for this VCL."
              ::= { atmNteConfVcEntry 1 }

          atmConfVcCCAdminStatus OBJECT-TYPE
             SYNTAX  INTEGER {
		        up(2), 
             	down(3), 
		        source(4),       -- agent send Oam CC cells 
		        sink(5),         -- agent check received Oam CC cells
                listenToActivationCells (6),
                originateActivationCells(7)     
                            } 
             MAX-ACCESS read-write
             STATUS current
             DESCRIPTION
             "up(2) - Activate Continuity Check (CC).
              down(3) - Deactivate CC.
		      source(4)      - Activate OAM CC(Continuity Check) of local agent
             			( start sending Oam cells to the remote side ).
      		  sink(5)  - Activate CC of remote agent ( start receiving Oam cells from
      		 	         remote side).
      		  listenToActivationCells (6) - Passive listener till gets an activation request
              originateActivationCells(7) - Sands Activation cell according to atmConfVcCCDirection."
             ::= {atmNteConfVcEntry 2}

          atmConfVcLoopbackAdminStatus OBJECT-TYPE
             SYNTAX INTEGER {
		      up(2),
		      down(3),
		      llid(4),
		      segment(5),
		      endToEnd(6),
		      segmentLlid(7),
		      endToEndLlid(8)
	         } 
             MAX-ACCESS read-write
             STATUS current
             DESCRIPTION
             "up(2) - Start loopback OAM cells.
             down(3) - Stop sending loopback OAM cells.
             
             For ace2002:
             up(2)   - Transmitting LB cells with llid all ones 
                       (i.e. FFFF..FF)
             down(3) - Not transmitting LB cells. 
             llid(4) - Transmitting LB cells with llid indicated 
                       in the address field.
             segment(5) - Transmitting Segment LB cells with llid
                       all ones. 
             endToEnd(6) - Transmitting End to End LB cells with llid
                       all ones. 
             segmentLlid(7) - Transmitting Segment LB cells with
                       llid indicated in the address field.  
             endToEndLlid(8) - Transmitting LB cells with llid
                       indicated in the address field.  
             
             This parameter value might be in conflict with 
             atmConfVcOamSupport value, since this parameter is for LB, 
             while atmConfVcOamSupport is for any other OAM cells."                   
             ::= {atmNteConfVcEntry 3}

	     atmConfVcLoopbackSinkAddress OBJECT-TYPE
             SYNTAX OCTET STRING  (SIZE(2..20))
             MAX-ACCESS read-write
             STATUS current
             DESCRIPTION
             "Destination address.
              For ace101: 2 bytes are used.
              For ace2002: 16 bytes are used."
             ::= {atmNteConfVcEntry 4}

	     atmConfVcCongestionControl OBJECT-TYPE
             SYNTAX OCTET STRING
             MAX-ACCESS read-write
             STATUS current
             DESCRIPTION
             "Each bit indicates a selection of one option 
                    as the following description.  All combinations 
                    are possible and legal.
                    The codes are: 
                    1 - EPD
                    2 - CLP
                    4 - EFCI.
                    For ace2002:
                    1 - Packet Discard."
             ::= {atmNteConfVcEntry 5}

         atmConfVcCCDirection OBJECT-TYPE
             SYNTAX  INTEGER {
		    	both  (2),
		    	none  (3), 
                source(4),      
                sink  (5)     
                       } 
             MAX-ACCESS read-write
             STATUS current
             DESCRIPTION
             "both(2)  - Agent send OAM CC cells and check receivev OAM CC cells
              none(3) - Agent does not send and does not check received OAM CC cells.
              source(4)- Agent send OAM CC cells.
 		      sink(5)  - Agent checks received OAM CC cells."    
             ::= {atmNteConfVcEntry 6}

         atmConfVcCreationTime OBJECT-TYPE
         SYNTAX   DateAndTime
         MAX-ACCESS   read-only
         STATUS   current
         DESCRIPTION
         "A date-time in which the VC was created."
         ::= { atmNteConfVcEntry 7 }

         atmConfVcOamSupport OBJECT-TYPE
             SYNTAX  INTEGER {
                  intermediate(1),
                  segmentTermination(2),
                  endToEndTermination(3),
                  segmentAndEndToEnd(4)
              }
             MAX-ACCESS  read-write
             STATUS  current
             DESCRIPTION
             "OAM support mode, which determines the device location
              in a segment wise.
                
              segmentAndEndToEnd -  In this mode the OAM cells are generated 
                                 before the ABM (ATM Buffer Manager), so 
                                 that the PCR and CDVT will not be affected."
             ::= { atmNteConfVcEntry 8 }

         atmConfVcCCActivationCtrl OBJECT-TYPE
             SYNTAX  INTEGER {
		             manual(1), 
                     activator(2), 
		             listener(3) 
                            } 
             MAX-ACCESS read-write
             STATUS current
             DESCRIPTION  
             "manual(1) - CC Activation process is disable
              activator(2) - ACE-101 initiate  CC Activation process
              listener(3) - ACE-101 wait to CC Activation request from remote side."
             ::= { atmNteConfVcEntry 9 }
    
          atmConfVcCCOperStatus OBJECT-TYPE
             SYNTAX  INTEGER {
					 initial(1),
		             up(2), 
            	     down(3), 
		             source(4),    -- agent send Oam CC cells 
		             sink(5),       -- agent check received Oam CC cells
					 both (8),
		 			 timeout (9), 
				     denied (10),
					 conflict (11),
					 manual (12)
                            } 
             MAX-ACCESS read-only
             STATUS current
             DESCRIPTION
             "initial (1) - The CC activation process is not started.
              up (2) -  Continuity Check (CC) activated.
              down (3) - CC deactivated.
              source (4)  -  OAM CC(Continuity Check) of local agent activated.
              sink (5)  -  OAM CC of remote agent activated.
			  both (8) - OAM CC of local and remote agents activation.
		      timeout (9) - Timeout occured on receiving answer from
                           the remote agent.
		      denied  (10) - CC activation process rejected by remote agent.
		      conflict (11) - local and remote sides requested activation
                              simultaneously.
			  manual (12) - OAM CC of local agent activated manually.
			 	"
             ::= { atmNteConfVcEntry 10 }

	      atmConfVcLoopbackTraffic OBJECT-TYPE
               SYNTAX INTEGER { off(2), on(3) } 
               MAX-ACCESS read-write
               STATUS current
               DESCRIPTION
               "This parameter has both command and status meanings: 
                off(2) - Set to 'Off' will Stop traffic loop. Getting this
                        value means that the loop is not running.
                on (3) - Set to 'On' will start traffic loop. Getting 
              	          this value means that the loop is currently running."
             ::= {atmNteConfVcEntry 11}

	      atmConfVcLoopbackFailureInd OBJECT-TYPE
             		SYNTAX INTEGER { 
             		disabled(2), 
             		segmentAis(3),
             		segmentRdi(4),
             		segmentAisAndRdi(5),
             		endToEndAis(6),
             		endToEndRdi(7),
             		endToEndAisAndRdi(8)
             		} 
             		MAX-ACCESS read-write
             		STATUS current
             		DESCRIPTION
    "This object allows user to define the Indication that will be created upon 
     a LB cell failure.
     disabled(2) - no indication will be created.
     segmentAis(3) - will cause Tx of a segment AIS.
     segmentRdi(4) - will cause Tx of a segment RDI.
     segmentAisAndRdi(5) - will cause Tx of a segment AIS & RDI. 
     endToEndAis(6) - will cause Tx of an End to End AIS.
     endToEndRdi(7)	- will cause Tx of an End to End RDI.
     endToEndAisAndRdi(8) - will cause Tx of an End to End AIS & RDI.
     Default: disabled(2)."
             ::= {atmNteConfVcEntry 12}

	atmConfVcLoopbackFailureThreshold OBJECT-TYPE
             		SYNTAX Integer32  
             		MAX-ACCESS read-write
             		STATUS current
             		DESCRIPTION
    "The number of the LB failures before starting transmission of the 
    Indication defined by atmConfVcLoopbackFailureInd.
    Range: 1..16. Default: 1."
             ::= {atmNteConfVcEntry 13}

atmConfVcOamDirection OBJECT-TYPE
	SYNTAX  INTEGER {
		notApplicable  (1), 
		downStream     (2),      
		upStream       (3)     
        } 
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
	"The direction of OAM cell insertion.
	 downStream(2) - The OAM cell will be inserted in downStream.     
	 upStream(3)   - The OAM cell will be inserted in upStream."    
	::= {atmNteConfVcEntry 14}

atmConfVcName OBJECT-TYPE
	SYNTAX  DisplayString 
    MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
	"VC Name."    
    ::= {atmNteConfVcEntry 15}

atmConfVcConnected OBJECT-TYPE
	SYNTAX  INTEGER {
		notConnected(1), 
		mng(2),      
		bridgePort(3)     
        } 
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
	"This object indicates whether this VC is connected."    
	::= {atmNteConfVcEntry 16}
-- 
-- file :v:\doc\rdv\mib\ver485\atm\radima.txt
-- 
-- RAD-IMA-MIB DEFINITIONS ::= BEGIN

--Title:    RAD-IMA   MIB
--
-- Copyright 1998 RAD Data Communications, Ltd.
-- All Rights Reserved.  

-- IMPORTS

--      OBJECT-TYPE                     FROM RFC-1212
 --     radWan                          FROM RAD-GEN-MIB;
--                RAD-IMA MIB   

--Title:     RAD's IMA INTERFACE MIB
--Version:   1.0
--Date:      15.09.98
--By:        Ilana Schvetz
--File:      radima.mib

-- Last Update 20.01.02 by Ilana Schvetz


radAtmIma  OBJECT IDENTIFIER  ::=  {radAtm 5}

imaPrimaryClk     OBJECT-TYPE
              SYNTAX  INTEGER { 
                             notApplicable(1),           
		                     link1(2),
		                     link2(3),
		                     link3(4),
		                     link4(5),
		                     automatic(6)
              }
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION 
                       "Clock source to be transmitted to the user side, 
                        where user module is in 'External' clock source."
             ::= { radAtmIma 1 }

-- An extension to the Link Table


imaXLinkTable  OBJECT-TYPE
       SYNTAX      SEQUENCE OF ImaXLinkEntry
       MAX-ACCESS  	   not-accessible
       STATUS      current
       DESCRIPTION
               "The IMA Link Status and Configuration table.
                This table contains additional objects for the link table."
       ::= { radAtmIma 2 }

imaXLinkEntry  OBJECT-TYPE
       SYNTAX  	   ImaXLinkEntry 
       MAX-ACCESS  	   not-accessible
       STATUS      current
       DESCRIPTION
               "An entry in the IMA Link table."
 --      AUGMENTS    { imaLinkTable }
         INDEX   { imaLinkIfIndex }
       ::= { imaXLinkTable 1 }

ImaXLinkEntry     ::=
      SEQUENCE {
        imaLinkDirection		    INTEGER,
        imaLinkItcLBClkSrc			INTEGER
}



imaLinkDirection  OBJECT-TYPE
              	SYNTAX  INTEGER { 
	                    	rx(1),
							tx(2),
							both(3)
	 			}
              	MAX-ACCESS  read-write
              	STATUS  current
              	DESCRIPTION
                      "the Link direction."
--	        	DEFAULT { both }	
              ::= { imaXLinkEntry 1 }

imaLinkItcLBClkSrc OBJECT-TYPE
              	SYNTAX  INTEGER { 
							link1(1),
							link2(2),
							link3(3),
							link4(4),
							internal (5),
							external (6),
							automatic(7),
							loopback (8)
	 			}
              	MAX-ACCESS  read-write
              	STATUS  current
              	DESCRIPTION
              	 		"Clock source for the current Tx-line."  
              ::= { imaXLinkEntry 2 }

-- An extension to the Group Table


imaXGroupTable  OBJECT-TYPE
       SYNTAX      SEQUENCE OF ImaXGroupEntry
       MAX-ACCESS  	   not-accessible
       STATUS      current
       DESCRIPTION
               "The IMA group Status and Configuration table.
                This table contains additional objects for the Group table."
       ::= { radAtmIma 3 }

imaXGroupEntry  OBJECT-TYPE
       SYNTAX  	   ImaXGroupEntry 
       MAX-ACCESS  	   not-accessible
       STATUS      current
       DESCRIPTION
               "An entry in the IMA Group table."
 --      AUGMENTS    { imaGroupTable }
         INDEX   { imaGroupIndex }
       ::= { imaXGroupTable 1 }

ImaXGroupEntry     ::=
      SEQUENCE {
		imaGroupVersion				INTEGER,
        imaGroupCtcTxClkSrc			INTEGER,
        imaGroupCtcTxClkSrcPort		Integer32
      }


imaGroupVersion     OBJECT-TYPE
              SYNTAX  INTEGER { 
                             ver10(1),           
		                     ver11(2)
              }
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION 
                       "IMA Version."
             ::= { imaXGroupEntry 1 }

imaGroupCtcTxClkSrc OBJECT-TYPE
              	SYNTAX  INTEGER { 
							link1     (1),
							link2     (2),
							link3     (3),
							link4     (4),
							internal  (5),           
							external  (6),
							automatic (7),           
							loopback  (8),           

							notApplicable(255)           
	 			}
              	MAX-ACCESS  read-write
              	STATUS  current
              	DESCRIPTION
              	 		"The source of the transmitted, common, Clock Source.
						 Applicable if imaGroupNeTxClkMode=ctc(1).
                         Automatic - Dynamic source, taken from the currently reference link. 
                         Internal  - taken from the Internal clock on card.
                         Loopback  - Looped back from one of the ports. In this case a specific 
                                     port should be selected for imaGroupCtcTxClkSrcPort parameter.
                         Link N    - Clock will be looped from one of the links."  
               ::= { imaXGroupEntry 2 }

imaGroupCtcTxClkSrcPort OBJECT-TYPE
               SYNTAX  Integer32
               MAX-ACCESS  read-write
               STATUS  current
               DESCRIPTION
                       "This parameter is valid only when imaGroupCtcTxClkSrc=loopback.
                        The value may be any port identifier."
               ::= { imaXGroupEntry 3 }

-- IMA Traps

--NOTIFICATIONS

atmImaGroupStatusChangeTrap NOTIFICATION-TYPE
      OBJECTS  { imaGroupFailureStatus }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates IMA Group status change."
	::= { radSysAtmEvents 80 }

-- 
-- file :v:\doc\rdv\mib\ver495\radhdlc.txt
-- 
-- RAD-HDLC-MIB DEFINITIONS ::= BEGIN

--Title:    RAD-HDLC   MIB
--
-- Copyright 1998 RAD Data Communications, Ltd.
-- All Rights Reserved.  


--Title:     RAD's HDLC MIB
--Version:   1.0
--Date:      15.09.98
--By:        Ilana Schvetz
--File:      radhdlc.mib
--
-- Last Update: 09-Oct-02 By Ilana Schvetz

hdlcMibObjects  OBJECT IDENTIFIER  ::=  {diverseIfWanGen 5}

hdlcTable  OBJECT-TYPE
       SYNTAX      SEQUENCE OF HdlcEntry
       MAX-ACCESS  	   not-accessible
       STATUS      current
       DESCRIPTION
               	"The HDLC configuration table."
       ::= { hdlcMibObjects 1 }

hdlcEntry  OBJECT-TYPE
       SYNTAX  	   HdlcEntry 
       MAX-ACCESS  	   not-accessible
       STATUS      current
       DESCRIPTION
				"Defines the contents of each line in the RAD HDLC Table."
       INDEX   { ifIndex }
       ::= { hdlcTable 1 }

HdlcEntry     ::=
      SEQUENCE {
        hdlcProtocol				INTEGER,
        hdlcRateResolution			INTEGER,
        hdlcTxClockSource			INTEGER,
        hdlcTerminalMode			INTEGER,
        hdlcLoopbackState			INTEGER,
        hdlcTxClockPolarity			INTEGER,
        hdlcFlowControl				INTEGER,
        hdlcLineRate				Integer32,
        hdlcRxClockMode				INTEGER,
        hdlcLOF						Gauge32,
        hdlcRxClockPolarity			INTEGER
}



hdlcProtocol     OBJECT-TYPE
              SYNTAX  INTEGER { 
                             notApplicable(1),           
		                     v35(2),
		                     x21(3),
		                     rs530(4)
              }
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION 
                       "The HDLC protocol type
                        V35 - HDLC encapsulated over V35
                        X21 - HDLC encapsulated over X21
                        RS530 - HDLC encapsulated over RS530"
              ::= { hdlcEntry 1 }


 
hdlcRateResolution  OBJECT-TYPE
    		SYNTAX INTEGER {
       					notApplicable(1),
       					nx56Kbps(2),
       					nx64Kbps(3)
      		}
    		MAX-ACCESS  read-write
    		STATUS  current
    		DESCRIPTION
					"The baud rate of the internal clock."
    		::= { hdlcEntry 2 }


hdlcTxClockSource  OBJECT-TYPE
    		SYNTAX INTEGER {
       					internal(1),
       					external(2)
      		}
    		MAX-ACCESS  read-write
    		STATUS  current
    		DESCRIPTION
					"The baud rate of the internal clock."
    		::= { hdlcEntry 3 }

hdlcTerminalMode  OBJECT-TYPE
    		SYNTAX INTEGER {
       					dce(1),
       					dte(2)
      		}
    		MAX-ACCESS  read-write
    		STATUS  current
    		DESCRIPTION
					"."
    		::= { hdlcEntry 4 }

hdlcLoopbackState OBJECT-TYPE
            SYNTAX  INTEGER { 
                            notApplicable(1),           
            				internal(2), 
            				external(3), 
            				disable(4) 
            }
            MAX-ACCESS  read-write
            STATUS  current
            DESCRIPTION
                    "internal - All data coming from the 
                    			network port is looped back
                     external - All data comming from the line is 
                     			looped back."
            ::= { hdlcEntry 5 }


hdlcTxClockPolarity  OBJECT-TYPE
    		SYNTAX INTEGER {
       					normal (1),
       					inverse(2)
      		}
    		MAX-ACCESS  read-write
    		STATUS  current
    		DESCRIPTION
					"normal  - The transmitted data is sampled at the middle of bit time
					 inverse - The transmitted data is sampled at the end of the bit time 
					 			(high data rate/long cable)."
    		::= { hdlcEntry 6 }

hdlcFlowControl  OBJECT-TYPE
    		SYNTAX INTEGER {
       					disable(1),
       					enable (2)
      		}
    		MAX-ACCESS  read-write
    		STATUS  current
    		DESCRIPTION
					"Enable/Disable the CTS/RTS flow control signals."
    		::= { hdlcEntry 7 }


hdlcLineRate  OBJECT-TYPE
    		SYNTAX Integer32     		
    		MAX-ACCESS  read-write
    		STATUS  current
    		DESCRIPTION
					"The rate values for HDLC are n*56/64Kbps, where 1<=n<=32, 64, 128
					 and the following values: 1544, 3088, 6176.
					 The rate values for HSSI is nMbps, where 1<=n<=52."
    		::= { hdlcEntry 8 }


hdlcRxClockMode  OBJECT-TYPE
    		SYNTAX INTEGER {
						notApplicable(1),
       					internal     (2),
       					external     (3)
      		}
    		MAX-ACCESS  read-write
    		STATUS  current
    		DESCRIPTION
					"."
    		::= { hdlcEntry 9 }


hdlcLOF  OBJECT-TYPE
    		SYNTAX 	Gauge32
    		MAX-ACCESS  read-only
    		STATUS  current
    		DESCRIPTION
					"Total number of seconds the port is in Loss Of Frame state."
    		::= { hdlcEntry 10 }


hdlcRxClockPolarity  OBJECT-TYPE
    		SYNTAX INTEGER {
       					normal (1),
       					inverse(2)
      		}
    		MAX-ACCESS  read-write
    		STATUS  current
    		DESCRIPTION
					"normal  - The received data is sampled at the middle of bit time
					 inverse - The received data is sampled at the end of the bit time 
					 			(high data rate/long cable)."
    		::= { hdlcEntry 11 }


hdlcPerformance  OBJECT IDENTIFIER  ::=  {hdlcMibObjects 2}


hdlcCurrentTable OBJECT-TYPE
      SYNTAX  SEQUENCE OF HdlcCurrentEntry
      MAX-ACCESS   not-accessible
      STATUS  current
      DESCRIPTION
         "The HDLC Current table."
      ::= { hdlcPerformance 1 }

hdlcCurrentEntry OBJECT-TYPE
      SYNTAX  HdlcCurrentEntry
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
         "An entry in the HDLC Current table."
      INDEX   { hdlcCurrentIfIndex }
      ::= { hdlcCurrentTable 1 }

HdlcCurrentEntry ::=
      SEQUENCE {
      hdlcCurrentIfIndex
           Integer32,
	  hdlcCurrentStatus
	       OCTET STRING,
      hdlcCurrentLOF
      	   Gauge32,
      hdlcCurrentInFrames
           Gauge32,
      hdlcCurrentInErrors
           Gauge32,
      hdlcCurrentOutFrames
           Gauge32,
      hdlcCurrentAbortedFrames
           Gauge32,
      hdlcCurrentLengthError
           Gauge32
      }

hdlcCurrentIfIndex OBJECT-TYPE
      SYNTAX      Integer32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
        "The index of the HDLC interface. 
        It may be ifIndex."
    ::= { hdlcCurrentEntry 1 }

hdlcCurrentStatus OBJECT-TYPE
	 SYNTAX OCTET STRING  (SIZE (4))
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
      "The statuses of the current interval:
         0 - Valid.
         1 - redundantLinkSwitch - the link has been switched 
             by a redundancy mechanism.
         2 - discontinuity - module was partialy out.
         4 - notValid - module is out."
      ::= { hdlcCurrentEntry 2 }

hdlcCurrentLOF OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of seconds the 
	   port is in Loss Of Frame state, encountered 
       by the HDLC interface in the current 15 minute interval."
      ::= { hdlcCurrentEntry 3 }

hdlcCurrentInFrames OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of received frames, 
	  encountered by the HDLC interface in the current 15 minute 
	  interval."
      ::= { hdlcCurrentEntry 4 }

hdlcCurrentInErrors OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of Errored received 
	  frames, encountered by the HDLC interface in the current 15 
	  minute interval."
      ::= { hdlcCurrentEntry 5 }

hdlcCurrentOutFrames OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of transmitted frames, 
	  encountered by the HDLC interface in the current 15 minute 
	  interval."
      ::= { hdlcCurrentEntry 6 }

hdlcCurrentAbortedFrames OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of frames, in which    
	  at least seven consecutive '1'-s (Abort sequence) were 
	  encountered by the HDLC interface in the current 15 minute 
	  interval."
      ::= { hdlcCurrentEntry 7 }

hdlcCurrentLengthError OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of received frames 
	  with length error, encountered by the HDLC interface in the 
	  current 15 minute interval."
      ::= { hdlcCurrentEntry 8 }


--Interval Table


hdlcIntervalTable OBJECT-TYPE
      SYNTAX  SEQUENCE OF HdlcIntervalEntry
      MAX-ACCESS   not-accessible
      STATUS  current
      DESCRIPTION
         "The HDLC Interval table."
      ::= { hdlcPerformance 2 }

hdlcIntervalEntry OBJECT-TYPE
      SYNTAX  HdlcIntervalEntry
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
         "An entry in the HDLC Interval table."
              INDEX   { hdlcIntervalIfIndex, hdlcIntervalNumber }
              ::= { hdlcIntervalTable 1 }

HdlcIntervalEntry ::=
      SEQUENCE {
      hdlcIntervalIfIndex
           Integer32,
      hdlcIntervalNumber
           Integer32,
	  hdlcIntervalStatus
	       OCTET STRING,
      hdlcIntervalLOF
      	   Gauge32,
      hdlcIntervalInFrames
           Gauge32,
      hdlcIntervalInErrors
           Gauge32,
      hdlcIntervalOutFrames
           Gauge32,
      hdlcIntervalAbortedFrames
           Gauge32,
      hdlcIntervalLengthError
           Gauge32
      }

hdlcIntervalIfIndex OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The index of the HDLC interface. 
        It may be ifIndex."
    ::= { hdlcIntervalEntry 1 }

hdlcIntervalNumber OBJECT-TYPE
    SYNTAX  Integer32 (1..96)
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
        "A number between 1 and 96, where 1 is the most
         recently completed 15 minute interval and 96 is
         the least recently completed 15 minutes interval
         (assuming that all 96 intervals exist)."
    ::= { hdlcIntervalEntry 2 }

hdlcIntervalStatus OBJECT-TYPE
	 SYNTAX OCTET STRING  (SIZE (4))
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
      "The statuses of the current interval:
         0 - Valid.
         1 - redundantLinkSwitch - the link has been switched 
             by a redundancy mechanism.
         2 - discontinuity - module was partialy out.
         4 - notValid - module is out."
      ::= { hdlcIntervalEntry 3 }

hdlcIntervalLOF OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of seconds the 
	  port is in Loss Of Frame state, encountered by an HDLC 
	  interface in one of the previous 96, individual 15 minute, 
	  intervals."
      ::= { hdlcIntervalEntry 4 }

hdlcIntervalInFrames OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of received frames,
	   encountered by the HDLC interface in one of the previous 96, 
	   individual 15 minute, intervals."
      ::= { hdlcIntervalEntry 5 }

hdlcIntervalInErrors OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of Errored received 
	  frames, encountered by the HDLC interface in one of the 
	  previous 96, individual 15 minute, intervals."
      ::= { hdlcIntervalEntry 6 }

hdlcIntervalOutFrames OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of transmitted 
	  frames, encountered by the HDLC interface in one of 
	  the previous 96, individual 15 minute, intervals."
      ::= { hdlcIntervalEntry 7 }
 
hdlcIntervalAbortedFrames OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of frames, in which    
	  at least seven consecutive '1'-s (Abort sequence) were 
	  encountered by the HDLC interface in one of the previous 96, 
	  individual 15 minute, intervals."
      ::= { hdlcIntervalEntry 8 }

hdlcIntervalLengthError OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of received frames 
	  with length error, encountered by the HDLC interface in 
	  one of the previous 96, individual 15 minute, intervals."
      ::= { hdlcIntervalEntry 9 }

-- 
-- file :v:\doc\rdv\mib\ver525\atm\ace101.txt
-- 
-- 
-- file :v:\doc\rdv\mib\ver525\ATM\ace101.txt

--RAD-ARC-MIB

--			DEFINITIONS ::= BEGIN

--Title:    RAD-ACE   MIB
--

-- IMPORTS
--      Gauge32, IpAddress                FROM RFC1155-SMI
--      ifIndex                         FROM IF-MIB
--      OBJECT-TYPE                     FROM RFC-1212
--      TRAP-TYPE                       FROM RFC-1215
--      radAtm, agnLed, agnIndication   FROM RAD-GEN-MIB
--	  RowStatus                         FROM SNMPv2-TC
--	  atmVplVpi, atmVclVpi, atmVclVci   FROM ATM-MIB;                  



--                RAD-ACE MIB   

--Title:     RAD's ARC ATM PRODUCT MIB
--Version:   1.0
--Date:      24.9.96
--By:        Yair Arian
--File:      arc.mib
--
--Last update: 19-Dec-2005 by Ilana Schvetz

atmGen  OBJECT IDENTIFIER  ::=  {radAtm 2}

atmPerfHistory  OBJECT IDENTIFIER  ::=  {atmGen 1}

atmIfPerformance  OBJECT IDENTIFIER  ::=  {atmPerfHistory 1}
-- aal5VccXTable  ::= { atmIfPerformance 4 }  in aal5.txt


          atmIfDataTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF AtmIfDataEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "The ATM interface Data table."
              ::= { atmIfPerformance 1 }

          atmIfDataEntry OBJECT-TYPE
              SYNTAX  AtmIfDataEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "An entry in the ATM interface Data table."
              INDEX   { ifIndex }
              ::= { atmIfDataTable 1 }

          AtmIfDataEntry ::=
              SEQUENCE {
                  atmIfTimeElapsed
                      Integer32,
                  atmIfValidIntervals
                      Integer32
              }

           atmIfTimeElapsed OBJECT-TYPE
               SYNTAX  Integer32 (0..899)
               MAX-ACCESS  read-only
               STATUS  current
               DESCRIPTION
                       "The number of seconds that have elapsed since
                       the beginning of the near end current error-
                       measurement period."
              ::= { atmIfDataEntry 1 }

          atmIfValidIntervals OBJECT-TYPE
              SYNTAX  Integer32 (0..96)
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The number of previous near end intervals for
                      which valid data was collected.  The value will be
                      96 unless the interface was brought online within
                      the last 24 hours, in which case the value will be
                      the number of complete 15 minute near end
                      intervals since the interface has been online."
              ::= { atmIfDataEntry 2 }


          -- the ATM interface Current

          -- The ATM interface current table contains various statistics being
          -- collected for the current 15 minute interval.

          atmIfCurrentTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF AtmIfCurrentEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "The ATM interface Current table."
              ::= { atmIfPerformance 2 }

          atmIfCurrentEntry OBJECT-TYPE
              SYNTAX  AtmIfCurrentEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "An entry in the ATM interface Current table."
              INDEX   { ifIndex }
              ::= { atmIfCurrentTable 1 }

          AtmIfCurrentEntry ::=
              SEQUENCE {
                  atmIfCurrentTxCells
                      Gauge32,
                  atmIfCurrentRxCells
                      Gauge32,
                  atmIfCurrentCorrectedHecs
                      Gauge32,
                  atmIfCurrentUncorrectedHecs
                      Gauge32,
				  atmIfCurrentHecErrorSeconds
                      Gauge32
              }

          atmIfCurrentTxCells OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of transmitted
                      cells, encountered by an ATM interface in
                      the current 15 minute interval."
              ::= { atmIfCurrentEntry 1 }

          atmIfCurrentRxCells OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of received
                      cells, encountered by an ATM
                      interface in the current 15 minute interval."
              ::= { atmIfCurrentEntry 2 }

          atmIfCurrentCorrectedHecs OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of cells with
                      corrected HEC errors, encountered by an
                      ATM interface in the current 15 minute
                      interval."
              ::= { atmIfCurrentEntry 3 }

          atmIfCurrentUncorrectedHecs OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of cells with
                      uncorrected HEC errors, encountered by an ATM
                      interface in the current 15 minute interval."
              ::= { atmIfCurrentEntry 4 }

          atmIfCurrentHecErrorSeconds OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of seconds with
                      HEC errors, encountered by an ATM	interface in 
                      the current 15 minute interval."
              ::= { atmIfCurrentEntry 5 }


          -- the ATM interface Interval

          -- The ATM interface Interval Table contains various statistics
          -- collected by each ATM Interface over the previous 24
          -- hours of operation.  The past 24 hours are broken into 96
          -- completed 15 minute intervals.

          atmIfIntervalTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF AtmIfIntervalEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "The ATM interface Interval table."
              ::= { atmIfPerformance 3 }

          atmIfIntervalEntry OBJECT-TYPE
              SYNTAX  AtmIfIntervalEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "An entry in the ATM interface Interval table."
              INDEX   { ifIndex, atmIfIntervalNumber }
              ::= { atmIfIntervalTable 1 }

          AtmIfIntervalEntry ::=
              SEQUENCE {
                  atmIfIntervalNumber
                      Integer32,
                  atmIfIntervalTxCells
                      Gauge32,
                  atmIfIntervalRxCells
                      Gauge32,
                  atmIfIntervalCorrectedHecs
                      Gauge32,
                  atmIfIntervalUncorrectedHecs
                      Gauge32,
                  atmIfIntervalHecErrorSeconds
                      Gauge32
              }

          atmIfIntervalNumber OBJECT-TYPE
              SYNTAX  Integer32 (1..96)
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "A number between 1 and 96, where 1 is the most
                      recently completed 15 minute interval and 96 is
                      the least recently completed 15 minutes interval
                      (assuming that all 96 intervals are valid)."
              ::= { atmIfIntervalEntry 1 }

          atmIfIntervalTxCells OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of transmitted 
                      cells , encountered by an ATM interface in
                      one of the previous 96, individual 15 minute,
                      intervals."
              ::= { atmIfIntervalEntry 2 }

          atmIfIntervalRxCells OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of received
                      cells, encountered by an ATM
                      interface in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmIfIntervalEntry 3 }

          atmIfIntervalCorrectedHecs OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of cells with
                      corrected HEC errors, encountered by an
                      ATM interface in one of the previous 96,
                      individual 15 minute, intervals."
              ::= { atmIfIntervalEntry 4 }

          atmIfIntervalUncorrectedHecs OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of cells with
                      uncorrected HEC errors, encountered by an ATM
                      interface in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmIfIntervalEntry 5 }

          atmIfIntervalHecErrorSeconds OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of seconds with
                      HEC errors, encountered by an ATM	interface in one of 
                      the previous 96, individual 15 minute, intervals."
              ::= { atmIfIntervalEntry 6 }


atmPvcPerformance  OBJECT IDENTIFIER  ::=  {atmPerfHistory 2}

atmVpPerformance  OBJECT IDENTIFIER  ::=  {atmPvcPerformance 1}

          -- the ATM VP Current

          -- The ATM VP current table contains various statistics being
          -- collected for the current 15 minute interval.

          atmVpCurrentTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF AtmVpCurrentEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "The ATM VP Current table."
              ::= { atmVpPerformance 1 }

          atmVpCurrentEntry OBJECT-TYPE
              SYNTAX  AtmVpCurrentEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "An entry in the ATM VP Current table."
              INDEX   { ifIndex, atmVpCurrentVpi }
              ::= { atmVpCurrentTable 1 }

          AtmVpCurrentEntry ::=
              SEQUENCE {
	     atmVpCurrentVpi
                      Integer32,
                  atmVpCurrentRxCellsClp01
                      Gauge32,
                  atmVpCurrentRxCellsClp0
                      Gauge32,
                  atmVpCurrentGcra0Violations
                      Gauge32,
                  atmVpCurrentGcra1Violations
                      Gauge32,
                  atmVpCurrentRxAIS
                      Gauge32,
                  atmVpCurrentTxAIS
                      Gauge32,
                  atmVpCurrentRxRDI
                      Gauge32,
                  atmVpCurrentTxRDI
                      Gauge32,
                  atmVpCurrentContinuityLoss
                      Gauge32,
                  atmVpCurrentUAS
                      Gauge32,
	              atmVpCurrentSES 
	                  Gauge32,
	              atmVpCurrentCDC
	                  Gauge32,
                  atmVpCurrentTotalDiscards     
                      Gauge32,
                  atmVpCurrentClp0Discards      
                      Gauge32,
                  atmVpCurrentTotalCellOuts     
                      Gauge32,
                  atmVpCurrentClp0CellOuts      
                      Gauge32,
                  atmVpCurrentTaggedOuts        
                      Gauge32,
	              atmVpCurrentPCR
	                  Gauge32,
	              atmVpCurrentSCR
	                  Gauge32,
	              atmVpCurrentMCR
	                  Gauge32,
                  atmVpCurrentShaperTotalDiscards     
                      Gauge32,
                  atmVpCurrentShaperClp0Discards      
                      Gauge32,
                  atmVpCurrentShaperClp1Discards      
                      Gauge32
          }

          atmVpCurrentVpi OBJECT-TYPE
              SYNTAX  Integer32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The VPI of the VPL."
              ::= { atmVpCurrentEntry 1 }

          atmVpCurrentRxCellsClp01 OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of transmitted
                      cells, encountered by the VPL of this ATM interface in
                      the current 15 minute interval."
              ::= { atmVpCurrentEntry 2 }

          atmVpCurrentRxCellsClp0 OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of received
                      cells, encountered by the VPL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVpCurrentEntry 3 }

          atmVpCurrentGcra0Violations OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of cells 
                      violating GCRA0, encountered by the VPL of this
                      ATM interface in the current 15 minute
                      interval."
              ::= { atmVpCurrentEntry 4 }

          atmVpCurrentGcra1Violations OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of cells 
                      violating GCRA1, encountered by the VPL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVpCurrentEntry 5 }

          atmVpCurrentRxAIS OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of received
                      AIS cells, encountered by the VPL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVpCurrentEntry 6 }

          atmVpCurrentTxAIS OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of transmitted
                      AIS cells, encountered by the VPL of this ATM
                      interface in the current 15 minute interval. Not Supported
	        in the first phase."
              ::= { atmVpCurrentEntry 7 }

          atmVpCurrentRxRDI OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of received
                      RDI cells, encountered by the VPL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVpCurrentEntry 8 }

          atmVpCurrentTxRDI OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of transmitted
                      RDI cells, encountered by the VPL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVpCurrentEntry 9 }

          atmVpCurrentContinuityLoss OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of loss of
                      continuity cells, encountered by the VPL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVpCurrentEntry 10 }

          atmVpCurrentUAS OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of Unavailable
                      Seconds, encountered by the VPL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVpCurrentEntry 11 }

	atmVpCurrentSES OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of Severerly Errored
                      Seconds, encountered by the VPL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVpCurrentEntry 12 }

 	atmVpCurrentCDC OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "Amount of cells dropped in the current 15 minute interval 
                       of the VP connection."
              ::= { atmVpCurrentEntry 13 }
                        
    atmVpCurrentTotalDiscards OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of valid ATM cells discarded by
                      the traffic policing entity.  This includes cells
                      originally received with CLP=0 and CLP=1."
              ::= { atmVpCurrentEntry 14 }

    atmVpCurrentClp0Discards OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of valid ATM cells received with
                      CLP=0 and discarded by the traffic policing
                      entity."
              ::= { atmVpCurrentEntry 15 }

    atmVpCurrentTotalCellOuts OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of valid ATM cells transmitted
                      by this VPL. This includes both CLP=0 and CLP=1
                      cells."
              ::= { atmVpCurrentEntry 16 }
                       
    atmVpCurrentClp0CellOuts OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of valid ATM cells transmitted
                      with CLP=0 by this VPL."
              ::= { atmVpCurrentEntry 17 }

    atmVpCurrentTaggedOuts OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of valid ATM cells tagged by the
                      traffic policing entity from CLP=0 to CLP=1 and
                      transmitted by this VPL."
              ::= { atmVpCurrentEntry 18 }
                        
	atmVpCurrentPCR OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The maximum traffic rate encountered in the 
                      last interval of the VP connection (monitored once a second)."
              ::= { atmVpCurrentEntry 19 }

	atmVpCurrentSCR OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The average traffic rate during the last interval of the VP 
                      connection."
              ::= { atmVpCurrentEntry 20 }

	atmVpCurrentMCR OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "MCR - The minimum traffic rate encountered in the last 
                      interval of the VP connection (monitored once a second)."
              ::= { atmVpCurrentEntry 21 }

    atmVpCurrentShaperTotalDiscards OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of cells (CLP0 and CLP1) discarded
                       due to congestion by the traffic shaper."
              ::= { atmVpCurrentEntry 22 }

    atmVpCurrentShaperClp0Discards OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of CLP0 cells discarded
                       due to congestion by the traffic shaper."
              ::= { atmVpCurrentEntry 23 }
    
    atmVpCurrentShaperClp1Discards OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of CLP1 cells discarded
                       due to congestion by the traffic shaper."
              ::= { atmVpCurrentEntry 24 }


          -- The ATM VP current table for Performance Management
          -- which contains various statistics being
          -- collected for the current 15 minute interval.

          atmVpPMCurrentTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF AtmVpPMCurrentEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "The ATM VP Current table for Performance Management."
              ::= { atmVpPerformance 2 }

          atmVpPMCurrentEntry OBJECT-TYPE
              SYNTAX  AtmVpPMCurrentEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "An entry in the ATM VP Current table for Performance
                       Management."
              INDEX   { ifIndex, atmVpPMCurrentVpi, atmVpPMCurrentDir }
              ::= { atmVpPMCurrentTable 1 }

          AtmVpPMCurrentEntry ::=
              SEQUENCE {
	atmVpPMCurrentDir			 
                      INTEGER,
	atmVpPMCurrentVpi			 
	        Integer32,
                  atmVpPMCurrentTxClp01
                      Gauge32,
                  atmVpPMCurrentTxClp0
                      Gauge32,
                  atmVpPMCurrentRxClp01
                      Gauge32,
                  atmVpPMCurrentRxClp0
                      Gauge32,
                  atmVpPMCurrentErroredCells
                      Gauge32,
                  atmVpPMCurrentLostCells
                      Gauge32,
                  atmVpPMCurrentMisinsertedCells
                      Gauge32,
                  atmVpPMCurrentECB
                      Gauge32,
                  atmVpPMCurrentSECB
                      Gauge32,
                  atmVpPMCurrentES
                      Gauge32,
                  atmVpPMCurrentSES
                      Gauge32,
                  atmVpPMCurrentUAS
                      Gauge32,
	              atmVpPMCurrentIntervalQuality
	                  INTEGER,
	              atmVpPMCurrentLastDayQuality
	                  INTEGER
              }

 	atmVpPMCurrentVpi OBJECT-TYPE
              SYNTAX  Integer32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The VPI of the VPL."
	::= { atmVpPMCurrentEntry 1 }

	atmVpPMCurrentDir OBJECT-TYPE
              SYNTAX  INTEGER {forward(2), backward(3) }
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The direction of performance management."	
	::= { atmVpPMCurrentEntry 2 }

          atmVpPMCurrentTxClp01 OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of transmitted 
                      CLP 0+1 cells, encountered by the VPL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVpPMCurrentEntry 3 }

          atmVpPMCurrentTxClp0 OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of transmitted
                      CLP 0	cells, encountered by the VPL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVpPMCurrentEntry 4 }

          atmVpPMCurrentRxClp01 OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of received
                      CLP 0+1 cells, encountered by the VPL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVpPMCurrentEntry 5 }

          atmVpPMCurrentRxClp0 OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of received
                      CLP 0 cells, encountered by the VPL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVpPMCurrentEntry 6 }

          atmVpPMCurrentErroredCells OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of errored
                      cells, encountered by the VPL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVpPMCurrentEntry 7 }

          atmVpPMCurrentLostCells OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of lost
                      cells, encountered by the VPL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVpPMCurrentEntry 8 }

          atmVpPMCurrentMisinsertedCells OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of misinserted
                      cells, encountered by the VPL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVpPMCurrentEntry 9 }

          atmVpPMCurrentECB OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of ECB,
                      encountered by the VPL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVpPMCurrentEntry 10 }

          atmVpPMCurrentSECB OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of SECB,
                      encountered by the VPL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVpPMCurrentEntry 11 }

          atmVpPMCurrentES OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of 
                      Errored Seconds, encountered by the VPL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVpPMCurrentEntry 12 }

          atmVpPMCurrentSES OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of Severely
                      Errored Seconds, encountered by the VPL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVpPMCurrentEntry 13 }

          atmVpPMCurrentUAS OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of Unavailable
                      Seconds, encountered by the VPL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVpPMCurrentEntry 14 }

	atmVpPMCurrentIntervalQuality OBJECT-TYPE
              SYNTAX  INTEGER { normal(2), unacceptable(3) }
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
		" If the number of errors per interval is superior to
		the atmNteUPLTCR value, the quality of service of
		the interval is declared as unacceptable."
	DEFVAL { normal }
	::= { atmVpPMCurrentEntry 15 }

	    atmVpPMCurrentLastDayQuality OBJECT-TYPE
              SYNTAX  INTEGER { normal(2), degraded(4) }
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
		" If the number of errors per 24 hours is superior to
		the atmNteDPLTCR value, the quality of service of
		the day is declared as degraded."
	DEFVAL { normal }
	::= { atmVpPMCurrentEntry 16 }


          -- the ATM VP Interval

          -- The ATM VP Interval Table contains various statistics
          -- collected by each ATM Interface/VP over the previous 24
          -- hours of operation.  The past 24 hours are broken into 96
          -- completed 15 minute intervals.

          atmVpIntervalTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF AtmVpIntervalEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "The ATM Vp Interval table."
              ::= { atmVpPerformance 3 }

          atmVpIntervalEntry OBJECT-TYPE
              SYNTAX  AtmVpIntervalEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "An entry in the ATM Vp Interval table."
              INDEX   { ifIndex, atmVpIntervalVpi, 
                        atmVpIntervalNumber }
              ::= { atmVpIntervalTable 1 }

          AtmVpIntervalEntry ::=
              SEQUENCE {
			      atmVpIntervalVpi
				      Integer32,
                  atmVpIntervalNumber
                      Integer32,
                  atmVpIntervalRxCellsClp01
                      Gauge32,
                  atmVpIntervalRxCellsClp0
                      Gauge32,
                  atmVpIntervalGcra0Violations
                      Gauge32,
                  atmVpIntervalGcra1Violations
                      Gauge32,
                  atmVpIntervalRxAIS
                      Gauge32,
                  atmVpIntervalTxAIS
                      Gauge32,
                  atmVpIntervalRxRDI
                      Gauge32,
                  atmVpIntervalTxRDI
                      Gauge32,
                  atmVpIntervalContinuityLoss
                      Gauge32,
                  atmVpIntervalUAS
                      Gauge32,
	              atmVpIntervalSES
	                  Gauge32,
	              atmVpIntervalCDC
	                  Gauge32,
                  atmVpIntervalTotalDiscards     
                      Gauge32,
                  atmVpIntervalClp0Discards      
                      Gauge32,
                  atmVpIntervalTotalCellOuts     
                      Gauge32,
                  atmVpIntervalClp0CellOuts      
                      Gauge32,
                  atmVpIntervalTaggedOuts        
                      Gauge32,
	              atmVpIntervalPCR
	                  Gauge32,
	              atmVpIntervalSCR
	                  Gauge32,
	              atmVpIntervalMCR
	                  Gauge32,
                  atmVpIntervalShaperTotalDiscards     
                      Gauge32,
                  atmVpIntervalShaperClp0Discards      
                      Gauge32,
                  atmVpIntervalShaperClp1Discards      
                      Gauge32
              }

          atmVpIntervalVpi OBJECT-TYPE
              SYNTAX  Integer32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The VPI of the VPL."
              ::= { atmVpIntervalEntry 1 }

          atmVpIntervalNumber OBJECT-TYPE
              SYNTAX  Integer32 (1..96)
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "A number between 1 and 96, where 1 is the most
                      recently completed 15 minute interval and 96 is
                      the least recently completed 15 minutes interval
                      (assuming that all 96 intervals are valid)."
              ::= { atmVpIntervalEntry 2 }

          atmVpIntervalRxCellsClp01 OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of transmitted 
                      cells , encountered by an ATM interface/VP in
                      one of the previous 96, individual 15 minute,
                      intervals."
              ::= { atmVpIntervalEntry 3 }

          atmVpIntervalRxCellsClp0 OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of received
                      cells, encountered by an ATM
                      interface/VP in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVpIntervalEntry 4 }

          atmVpIntervalGcra0Violations OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of
                      cells violating GCRA0, encountered by an ATM
                      interface/VP in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVpIntervalEntry 5 }

          atmVpIntervalGcra1Violations OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of
                      cells violating GCRA1, encountered by an ATM
                      interface/VP in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVpIntervalEntry 6 }

          atmVpIntervalRxAIS OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of received
                      AIS cells, encountered by an ATM
                      interface/VP in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVpIntervalEntry 7 }

          atmVpIntervalTxAIS OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of transmitted
                      AIS cells, encountered by an ATM
                      interface/VP in one of the previous 96, individual 15
                      minute, intervals. Not supported in the first phase."
              ::= { atmVpIntervalEntry 8 }

          atmVpIntervalRxRDI OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of received
                      RDI cells, encountered by an ATM
                      interface/VP in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVpIntervalEntry 9 }

          atmVpIntervalTxRDI OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of transmitted
                      RDI cells, encountered by an ATM
                      interface/VP in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVpIntervalEntry 10 }

          atmVpIntervalContinuityLoss OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of Continuity
                      Loss cells, encountered by an ATM
                      interface/VP in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVpIntervalEntry 11 }

          atmVpIntervalUAS OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of Unavailable
                      Seconds, encountered by an ATM
                      interface/VP in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVpIntervalEntry 12 }

	atmVpIntervalSES OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of Severerly Errored
                      Seconds, encountered by an ATM
                      interface/VP in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVpIntervalEntry 13 }

	atmVpIntervalCDC OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "Amount of cells dropped in the 15 minute interval 
                       of the VP connection."
              ::= { atmVpIntervalEntry 14 }

    atmVpIntervalTotalDiscards OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of valid ATM cells discarded by
                      the traffic policing entity.  This includes cells
                      originally received with CLP=0 and CLP=1."
              ::= { atmVpIntervalEntry 15 }

    atmVpIntervalClp0Discards OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of valid ATM cells received with
                      CLP=0 an  discarded by the traffic policing
                      entity."
              ::= { atmVpIntervalEntry 16 }

    atmVpIntervalTotalCellOuts OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of valid ATM cells transmitted
                      by this VPL.  This includes both CLP=0 and CLP=1
                      cells."
              ::= { atmVpIntervalEntry 17 }
                        
                       
    atmVpIntervalClp0CellOuts OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of valid ATM cells transmitted
                      with CLP=0 by this VPL."
              ::= { atmVpIntervalEntry 18 }

    atmVpIntervalTaggedOuts OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of valid ATM cells tagged by the
                      traffic policing entity from CLP=0 to CLP=1 and
                      transmitted by this VPL."
              ::= { atmVpIntervalEntry 19 }
                        
	atmVpIntervalPCR OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                     "The maximum traffic rate encountered in the last 
                     interval of the VP connection (monitored once a second)  
                     encountered by an ATM interface/VP in one of the previous 
                     96, individual 15 minute, intervals."
              ::= { atmVpIntervalEntry 20 }

	atmVpIntervalSCR OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                     "The average traffic rate during the last interval of the 
                     VP connection , encountered by an ATM interface/VP in one 
                     of the previous 96, individual 15 minute, intervals."
              ::= { atmVpIntervalEntry 21 }

	atmVpIntervalMCR OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                     "MCR - The minimum traffic rate encountered in the last 
                     interval of the VP connection (monitored once a second)  
                     encountered by an ATM interface/VP in one of the previous 
                     96, individual 15 minute, intervals."
              ::= { atmVpIntervalEntry 22 }

    atmVpIntervalShaperTotalDiscards OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of cells (CLP0 and CLP1) discarded
                       due to congestion by the traffic shaper."
              ::= { atmVpIntervalEntry 23 }

    atmVpIntervalShaperClp0Discards OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of CLP0 cells discarded
                       due to congestion by the traffic shaper."
              ::= { atmVpIntervalEntry 24 }
    
    atmVpIntervalShaperClp1Discards OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of CLP1 cells discarded
                       due to congestion by the traffic shaper."
              ::= { atmVpIntervalEntry 25 }


          -- The ATM VP Interval Table for Performance Management
          -- contains various statistics
          -- collected by each ATM Interface/VP over the previous 24
          -- hours of operation.  The past 24 hours are broken into 96
          -- completed 15 minute intervals.

          atmVpPMIntervalTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF AtmVpPMIntervalEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "The ATM Vp Interval table for Performance Management."
              ::= { atmVpPerformance 4 }

          atmVpPMIntervalEntry OBJECT-TYPE
              SYNTAX  AtmVpPMIntervalEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "An entry in the ATM Vp Interval table for Performance
                       Management."
              INDEX   { ifIndex, atmVpPMIntervalVpi, atmVpPMIntervalDir, atmVpPMIntervalNumber }
              ::= { atmVpPMIntervalTable 1 }

          AtmVpPMIntervalEntry ::=
              SEQUENCE {
	              atmVpPMIntervalVpi
	                  Integer32,
	              atmVpPMIntervalDir 
	                  INTEGER,
 	              atmVpPMIntervalNumber 
 	                  Integer32,
                  atmVpPMIntervalTxClp01
                      Gauge32,
                  atmVpPMIntervalTxClp0
                      Gauge32,
                  atmVpPMIntervalRxClp01
                      Gauge32,
                  atmVpPMIntervalRxClp0
                      Gauge32,
                  atmVpPMIntervalErroredCells
                      Gauge32,
                  atmVpPMIntervalLostCells
                      Gauge32,
                  atmVpPMIntervalMisinsertedCells
                      Gauge32,
                  atmVpPMIntervalECB
                      Gauge32,
                  atmVpPMIntervalSECB
                      Gauge32,
                  atmVpPMIntervalES
                      Gauge32,
                  atmVpPMIntervalSES
                      Gauge32,
                  atmVpPMIntervalUAS
                      Gauge32,
	              atmVpPMIntervalQuality
		              INTEGER,
	              atmVpPMIntervalLastDayQuality
		              INTEGER
              }

          atmVpPMIntervalVpi OBJECT-TYPE
              SYNTAX  Integer32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The VPI of the VPL."
              ::= { atmVpPMIntervalEntry 1 }

          atmVpPMIntervalDir OBJECT-TYPE
              SYNTAX  INTEGER {forward(2),
			                   backward(3) }
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The direction of performance management."
              ::= { atmVpPMIntervalEntry 2 }

          atmVpPMIntervalNumber OBJECT-TYPE
              SYNTAX  Integer32 (1..96)
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "A number between 1 and 96, where 1 is the most
                      recently completed 15 minute interval and 96 is
                      the least recently completed 15 minutes interval
                      (assuming that all 96 intervals are valid)."
              ::= { atmVpPMIntervalEntry 3 }

          atmVpPMIntervalTxClp01 OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of transmitted
                      CLP 0+1 cells, encountered by an ATM
                      interface/VP in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVpPMIntervalEntry 4 }

          atmVpPMIntervalTxClp0 OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of transmitted
                      CLP 0 cells, encountered by an ATM
                      interface/VP in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVpPMIntervalEntry 5 }

          atmVpPMIntervalRxClp01 OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of received
                      CLP 0+1 cells, encountered by an ATM
                      interface/VP in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVpPMIntervalEntry 6 }

          atmVpPMIntervalRxClp0 OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of received
                      CLP 0 cells, encountered by an ATM
                      interface/VP in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVpPMIntervalEntry 7 }

          atmVpPMIntervalErroredCells OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of Errored
                      cells, encountered by an ATM
                      interface/VP in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVpPMIntervalEntry 8 }

          atmVpPMIntervalLostCells OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of Lost
                      cells, encountered by an ATM
                      interface/VP in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVpPMIntervalEntry 9 }

          atmVpPMIntervalMisinsertedCells OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of Misinserted
                      cells, encountered by an ATM
                      interface/VP in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVpPMIntervalEntry 10 }

          atmVpPMIntervalECB OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of ECBs
                      encountered by an ATM
                      interface/VP in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVpPMIntervalEntry 11 }

          atmVpPMIntervalSECB OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of SECBs
                      encountered by an ATM
                      interface/VP in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVpPMIntervalEntry 12 }

          atmVpPMIntervalES OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of Errored
                      Seconds, encountered by an ATM
                      interface/VP in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVpPMIntervalEntry 13 }

          atmVpPMIntervalSES OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of Severely
                      Errored Seconds, encountered by an ATM
                      interface/VP in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVpPMIntervalEntry 14 }

          atmVpPMIntervalUAS OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of Unavailable
                      Seconds, encountered by an ATM
                      interface/VP in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVpPMIntervalEntry 15 }

	atmVpPMIntervalQuality OBJECT-TYPE
              		SYNTAX  INTEGER { normal(2), unacceptable(3) }
		MAX-ACCESS read-only
		STATUS current
		DESCRIPTION
		" If the number of errors per interval is superior to
		the atmNteUPLTCR value, the quality of service of
		the interval is declared as unacceptable."
		DEFVAL { normal }
	::= { atmVpPMIntervalEntry 16}

	    atmVpPMIntervalLastDayQuality OBJECT-TYPE
              		SYNTAX  INTEGER { normal(2), degraded(4) }
		MAX-ACCESS read-only
		STATUS current
		DESCRIPTION
		" If the number of errors per 24 hours is superior to
		the atmNteDPLTCR value, the quality of service of
		the day is declared as degraded."
		DEFVAL { normal }
	::= { atmVpPMIntervalEntry 17}

-- VP QoS Table

atmVpQoSTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF AtmVpQoSEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
        "The VP QoS table."
    ::= { atmVpPerformance 5 }

atmVpQoSEntry OBJECT-TYPE
    SYNTAX  AtmVpQoSEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
        "."
    INDEX   { ifIndex, atmVplVpi, atmVpQoSPeriodRef }
    ::= { atmVpQoSTable 1 }

AtmVpQoSEntry ::=
    SEQUENCE {
	          atmVpQoSPeriodRef     INTEGER,
	          atmVpQoSElapsedTime	Integer32,
	          atmVpQoSUAS		    Gauge32
             }

atmVpQoSPeriodRef OBJECT-TYPE
	SYNTAX  INTEGER { 
	                 currentPeriod (1), 
	                 lastPeriod    (2) 
                 	} 
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION
	    "This object is an index that specifies which period of time, the next 
	     2 objects refer to.
	     currentPeriod - the period since last systemResetAllStatsCmd received or
	                     since Start-up (if no systemResetAllStatsCmd was received since
	                     Start-up) until now.
	     lastPeriod    - the period between last two commands of systemResetAllStatsCmd.
	                     - If only one command occurred since Start-up: the period between 
	                       Start-up and last command.
	                     - If no command occurred since Start-up: this period will not 
	                       actually exist. In this case, he following 5 objects will be 0."
	::= { atmVpQoSEntry 1 }

atmVpQoSElapsedTime OBJECT-TYPE
	SYNTAX  Integer32 
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION
	    "Elapsed Time in seconds.
	     - for atmVpQoSPeriodRef = currentPeriod:
	       The period since last systemResetAllStatsCmd received or	since Start-up 
	       (if no systemResetAllStatsCmd was received since	Start-up) until now.
	     - for atmVpQoSPeriodRef = lastPeriod:
	       The value of atmVpQoSElapsedTime when last systemResetAllStatsCmd
	       was received."
	::= { atmVpQoSEntry 2 }

atmVpQoSUAS OBJECT-TYPE
	SYNTAX  Gauge32 
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION
	    "Number of Unavailable Seconds for the reference period (atmVpQoSPeriodRef)."
	::= { atmVpQoSEntry 3 }

-- VP PM QoS Table

atmVpPMQoSTable OBJECT-TYPE
     SYNTAX  SEQUENCE OF AtmVpPMQoSEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
         "The PM VP QoS table."
     ::= { atmVpPerformance 6 }

atmVpPMQoSEntry OBJECT-TYPE
     SYNTAX  AtmVpPMQoSEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
         "."
     INDEX   { ifIndex, atmVplVpi, atmVpPMQoSDirection ,atmVpPMQoSPeriodRef }
     ::= { atmVpPMQoSTable 1 }

AtmVpPMQoSEntry ::=
     SEQUENCE {
               atmVpPMQoSDirection	   INTEGER,
	           atmVpPMQoSPeriodRef	   INTEGER,
	           atmVpPMQoSCLR		   Gauge32,
	           atmVpPMQoSCER           Gauge32,
	           atmVpPMQoSCMR           Gauge32
              }

atmVpPMQoSDirection OBJECT-TYPE
     SYNTAX  INTEGER 
           {
            forward  (2),
			backward (3) 
		   }
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
          "The direction of performance management."
      ::= { atmVpPMQoSEntry 1 }

atmVpPMQoSPeriodRef OBJECT-TYPE
	 SYNTAX  INTEGER 
	      {
           currentPeriod  (1),
           lastPeriod     (2)
	      }
	 MAX-ACCESS  read-only
	 STATUS  current
	 DESCRIPTION
	     "This object is an index that specifies which period of time, the next
	      5 objects refer to.
	      currentPeriod - the period since last systemResetAllStatsCmd received or
	                      since Start-up (if no systemResetAllStatsCmd was received since
	                      Start-up) until now.
	      lastPeriod    - the period between last two commands of systemResetAllStatsCmd.
	                      - If only one command occurred since Start-up: the period between 
	                        Start-up and last command.
	                      - If no command occurred since Start-up: this period will not 
	                        actually exist. In this case, he following 5 objects will be 0."
	::= { atmVpPMQoSEntry 2 }


atmVpPMQoSCLR OBJECT-TYPE
	SYNTAX  Gauge32 
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION
	"Cell Loss Ratio counter for the reference period (atmVpPMQoSPeriodRef)- 
	defined in accordance with I.356 , in %.
	The value will be multipuled by 100."
	::= { atmVpPMQoSEntry 3 }

atmVpPMQoSCER OBJECT-TYPE
	SYNTAX  Gauge32 
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION
	"Cell Error Ratio counter for the reference period (atmVpPMQoSPeriodRef) 
	defined in accordance with I.356 , in %.
	The value will be multipuled by 100."
	::= { atmVpPMQoSEntry 4 }

atmVpPMQoSCMR OBJECT-TYPE
	SYNTAX  Gauge32 
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION
	"Cell Misinsertion Ratio counter for the reference period (atmVpPMQoSPeriodRef) 
	defined in accordance with I.356 , cells/sec ."
	::= { atmVpPMQoSEntry 5 }

--VP Shaper Statistics Table
atmVpShaperStatTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF AtmVpShaperStatEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "The ATM VP shaper statistics table."
              ::= { atmVpPerformance 7 }

          atmVpShaperStatEntry OBJECT-TYPE
              SYNTAX  AtmVpShaperStatEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "An entry in the ATM VP shaper statistics table."
              INDEX   { ifIndex, atmVplVpi }
              ::= { atmVpShaperStatTable 1 }

AtmVpShaperStatEntry ::=
     SEQUENCE {
	           atmVpShaperDiscarded          Counter32,
               atmVpShaperOccupation         Integer32,
               atmVpShaperMaxOccupation 	 Integer32,
               atmVpShaperLevel 			 INTEGER,
               atmVpShaperEpdDropped 		 Counter32,
               atmVpShaperTotalEpdDropped 	 Counter32
              }


atmVpShaperDiscarded OBJECT-TYPE
              SYNTAX  Counter32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                   "The number of Cells that were discarded in the shaper on that VPC due 
                    to buffer overflow. 
                    This counter counts till it reaches its MAX value (20 bits) and then 
                    rolls over."
              ::= { atmVpShaperStatEntry 1 }

atmVpShaperOccupation OBJECT-TYPE
              SYNTAX  Integer32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                   "The number of Cells that are currently stored in the buffer.
                   This parameter is limited to 20 bits."
              ::= { atmVpShaperStatEntry 2}

atmVpShaperMaxOccupation OBJECT-TYPE
              SYNTAX  Integer32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                   "The Maximum number of Cells that were stored in the buffer, 
                   since this VP was activated.	This parameter is limited to 20 bits." 
              ::= { atmVpShaperStatEntry 3}

atmVpShaperLevel OBJECT-TYPE
	          SYNTAX  INTEGER { 
	                 empty   (1), 
	                 full    (2), 
	                 below   (3),
	                 above   (4)
                 	} 
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                   "The occupation of the buffer according to a predefined threshold.
                   empty - buffer is Empty
                   full  - buffer is Full 
                   below - buffer is Below the threshold
                   above - buffer is Above the threshold. This is also the trigger to 
                   start EPD\PPD mechanism, if set for the VPC."
              ::= { atmVpShaperStatEntry 4}

atmVpShaperEpdDropped OBJECT-TYPE
              SYNTAX  Counter32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                   "The number of Cells that were dropped in the shaper on that VPC 
                   due to EPD\PPD mechanism in the last second.
                   This parameter is limited to 24 bits.
                   Applicable for a EPD/PPD VP only."
              ::= { atmVpShaperStatEntry 5}

atmVpShaperTotalEpdDropped OBJECT-TYPE
              SYNTAX  Counter32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                   "The Total number of Cells that were dropped in the shaper on that 
                   VPC due to EPD\PPD mechanism in the last 15 minutes. This counter 
                   automatically reset itself every 15 minutes.
                   Applicable for a EPD/PPD VP only."
              ::= { atmVpShaperStatEntry 6}


atmVcPerformance  OBJECT IDENTIFIER  ::=  {atmPvcPerformance 2}

          -- the ATM VC Current

          -- The ATM VC current table contains various statistics being
          -- collected for the current 15 minute interval.

          atmVcCurrentTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF AtmVcCurrentEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "The ATM VC Current table."
              ::= { atmVcPerformance 1 }

          atmVcCurrentEntry OBJECT-TYPE
              SYNTAX  AtmVcCurrentEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "An entry in the ATM VC Current table."
              INDEX   { ifIndex, atmVcCurrentVpi, atmVcCurrentVci }
              ::= { atmVcCurrentTable 1 }

          AtmVcCurrentEntry ::=
              SEQUENCE {
				  atmVcCurrentVpi
                      Integer32,
				  atmVcCurrentVci
				      Integer32,
                  atmVcCurrentRxCellsClp01
                      Gauge32,
                  atmVcCurrentRxCellsClp0
                      Gauge32,
                  atmVcCurrentGcra0Violations
                      Gauge32,
                  atmVcCurrentGcra1Violations
                      Gauge32,
                  atmVcCurrentRxAIS
                      Gauge32,
                  atmVcCurrentTxAIS
                      Gauge32,
                  atmVcCurrentRxRDI
                      Gauge32,
                  atmVcCurrentTxRDI
                      Gauge32,
                  atmVcCurrentContinuityLoss
                      Gauge32,
                  atmVcCurrentUAS
                      Gauge32,
	              atmVcCurrentSES     
	                  Gauge32,
	              atmVcCurrentCDC
	                  Gauge32,
                  atmVcCurrentTotalDiscards     
                      Gauge32,
                  atmVcCurrentClp0Discards      
                      Gauge32,
                  atmVcCurrentTotalCellOuts     
                      Gauge32,
                  atmVcCurrentClp0CellOuts      
                      Gauge32,
                  atmVcCurrentTaggedOuts        
                      Gauge32,
	              atmVcCurrentPCR
	                  Gauge32,
	              atmVcCurrentSCR
	                  Gauge32,
	              atmVcCurrentMCR
	                  Gauge32,
                  atmVcCurrentShaperTotalDiscards     
                      Gauge32,
                  atmVcCurrentShaperClp0Discards      
                      Gauge32,
                  atmVcCurrentShaperClp1Discards      
                      Gauge32
              }

          atmVcCurrentVpi OBJECT-TYPE
              SYNTAX  Integer32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The VPI of the VCL."
              ::= { atmVcCurrentEntry 1 }

          atmVcCurrentVci OBJECT-TYPE
              SYNTAX  Integer32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The VCI of the VCL."
              ::= { atmVcCurrentEntry 2 }

          atmVcCurrentRxCellsClp01 OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of transmitted
                      cells, encountered by the VCL of this ATM interface in
                      the current 15 minute interval."
              ::= { atmVcCurrentEntry 3 }

          atmVcCurrentRxCellsClp0 OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of received
                      cells, encountered by the VCL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVcCurrentEntry 4 }

          atmVcCurrentGcra0Violations OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of cells 
                      violating GCRA0, encountered by the VCL of this
                      ATM interface in the current 15 minute
                      interval."
              ::= { atmVcCurrentEntry 5 }

          atmVcCurrentGcra1Violations OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of cells 
                      violating GCRA1, encountered by the VCL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVcCurrentEntry 6 }

          atmVcCurrentRxAIS OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of received
                      AIS cells, encountered by the VCL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVcCurrentEntry 7 }

          atmVcCurrentTxAIS OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of transmitted
                      AIS cells, encountered by the VCL of this ATM
                      interface in the current 15 minute interval. Not Supported
	        in the first phase."
              ::= { atmVcCurrentEntry 8 }

          atmVcCurrentRxRDI OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of received
                      RDI cells, encountered by the VCL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVcCurrentEntry 9 }

          atmVcCurrentTxRDI OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of transmitted
                      RDI cells, encountered by the VCL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVcCurrentEntry 10 }

          atmVcCurrentContinuityLoss OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of loss of
                      continuity cells, encountered by the VCL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVcCurrentEntry 11 }

          atmVcCurrentUAS OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of Unavailable
                      Seconds, encountered by the VCL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVcCurrentEntry 12 }


 	atmVcCurrentSES OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of Severerly Errored
                      Seconds, encountered by the VCL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVcCurrentEntry 13 }

	atmVcCurrentCDC OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "Amount of cells dropped in the current 15 minute interval 
                       of the VC connection."
              ::= { atmVcCurrentEntry 14 }

    atmVcCurrentTotalDiscards OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of valid ATM cells discarded by
                      the traffic policing entity.  This includes cells
                      originally received with CLP=0 and CLP=1."
              ::= { atmVcCurrentEntry 15 }

    atmVcCurrentClp0Discards OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of valid ATM cells received with
                      CLP=0 an  discarded by the traffic policing
                      entity."
              ::= { atmVcCurrentEntry 16 }

    atmVcCurrentTotalCellOuts OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of valid ATM cells transmitted
                      by this VPL.  This includes both CLP=0 and CLP=1
                      cells."
              ::= { atmVcCurrentEntry 17 }
                       
    atmVcCurrentClp0CellOuts OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of valid ATM cells transmitted
                      with CLP=0 by this VPL."
              ::= { atmVcCurrentEntry 18 }

    atmVcCurrentTaggedOuts OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of valid ATM cells tagged by the
                      traffic policing entity from CLP=0 to CLP=1 and
                      transmitted by this VPL."
              ::= { atmVcCurrentEntry 19 }
                        
	atmVcCurrentPCR OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The maximum traffic rate encountered in the last 
                      interval of the VC connection (monitored once a second)."
              ::= { atmVcCurrentEntry 20 }

	atmVcCurrentSCR OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The average traffic rate during the last interval 
                      of the VC connection."
              ::= { atmVcCurrentEntry 21 }

	atmVcCurrentMCR OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "MCR - The minimum traffic rate encountered in the last 
                      interval of the VC connection (monitored once a second)."
              ::= { atmVcCurrentEntry 22 }

    atmVcCurrentShaperTotalDiscards OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of cells (CLP0 and CLP1) discarded
                       due to congestion by the traffic shaper."
              ::= { atmVcCurrentEntry 23 }

    atmVcCurrentShaperClp0Discards OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of CLP0 cells discarded
                       due to congestion by the traffic shaper."
              ::= { atmVcCurrentEntry 24 }
    
    atmVcCurrentShaperClp1Discards OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of CLP1 cells discarded
                       due to congestion by the traffic shaper."
              ::= { atmVcCurrentEntry 25 }


          -- The ATM VC current table for Performance Management
          -- which contains various statistics being
          -- collected for the current 15 minute interval.

          atmVcPMCurrentTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF AtmVcPMCurrentEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "The ATM VC Current table for Performance Management."
              ::= { atmVcPerformance 2 }

          atmVcPMCurrentEntry OBJECT-TYPE
              SYNTAX  AtmVcPMCurrentEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "An entry in the ATM VC Current table for Performance
                       Management."
              INDEX   { ifIndex, atmVcPMCurrentVpi, 
                        atmVcPMCurrentVci, atmVcPMCurrentDir }
              ::= { atmVcPMCurrentTable 1 }

          AtmVcPMCurrentEntry ::=
              SEQUENCE {
	              atmVcPMCurrentVpi
                      Integer32,
	              atmVcPMCurrentVci
	                  Integer32,
	              atmVcPMCurrentDir
	                  Integer32,
                  atmVcPMCurrentTxClp01
                      Gauge32,
                  atmVcPMCurrentTxClp0
                      Gauge32,
                  atmVcPMCurrentRxClp01
                      Gauge32,
                  atmVcPMCurrentRxClp0
                      Gauge32,
                  atmVcPMCurrentErroredCells
                      Gauge32,
                  atmVcPMCurrentLostCells
                      Gauge32,
                  atmVcPMCurrentMisinsertedCells
                      Gauge32,
                  atmVcPMCurrentECB
                      Gauge32,
                  atmVcPMCurrentSECB
                      Gauge32,
                  atmVcPMCurrentES
                      Gauge32,
                  atmVcPMCurrentSES
                      Gauge32,
                  atmVcPMCurrentUAS
                      Gauge32,
	              atmVcPMCurrentIntervalQuality
	                  INTEGER,
	              atmVcPMCurrentLastDayQuality
	                  INTEGER
                  }

          atmVcPMCurrentVpi OBJECT-TYPE
              SYNTAX  Integer32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The VPI of the VCL."
              ::= { atmVcPMCurrentEntry 1 }

          atmVcPMCurrentVci OBJECT-TYPE
              SYNTAX  Integer32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The VCI of the VCL."
              ::= { atmVcPMCurrentEntry 2 }

          atmVcPMCurrentDir OBJECT-TYPE
              SYNTAX  Integer32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The direction of Performance Management."
              ::= { atmVcPMCurrentEntry 3 }

          atmVcPMCurrentTxClp01 OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of transmitted 
                      CLP 0+1 cells, encountered by the VCL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVcPMCurrentEntry 4 }

          atmVcPMCurrentTxClp0 OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of transmitted
                      CLP 0	cells, encountered by the VCL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVcPMCurrentEntry 5 }

          atmVcPMCurrentRxClp01 OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of received
                      CLP 0+1 cells, encountered by the VCL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVcPMCurrentEntry 6 }

          atmVcPMCurrentRxClp0 OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of received
                      CLP 0 cells, encountered by the VCL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVcPMCurrentEntry 7 }

          atmVcPMCurrentErroredCells OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of errored
                      cells, encountered by the VCL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVcPMCurrentEntry 8 }

          atmVcPMCurrentLostCells OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of lost
                      cells, encountered by the VCL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVcPMCurrentEntry 9 }

          atmVcPMCurrentMisinsertedCells OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of misinserted
                      cells, encountered by the VCL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVcPMCurrentEntry 10 }

          atmVcPMCurrentECB OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of ECBs
                      encountered by the VCL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVcPMCurrentEntry 11 }

          atmVcPMCurrentSECB OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of SECBs
                      encountered by the VCL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVcPMCurrentEntry 12 }

          atmVcPMCurrentES OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of 
                      Errored Seconds, encountered by the VCL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVcPMCurrentEntry 13 }

          atmVcPMCurrentSES OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of Severely
                      Errored Seconds, encountered by the VCL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVcPMCurrentEntry 14 }

          atmVcPMCurrentUAS OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of Severely
                      Errored Seconds, encountered by the VCL of this ATM
                      interface in the current 15 minute interval."
              ::= { atmVcPMCurrentEntry 15 }

atmVcPMCurrentIntervalQuality OBJECT-TYPE
              SYNTAX  INTEGER { normal(2), unacceptable(3) }
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
		" If the number of errors per interval is superior to
		the atmNteUPLTCR value, the quality of service of
		the interval is declared as unacceptable."
	DEFVAL { normal }
	::= { atmVcPMCurrentEntry 16 }

	    atmVcPMCurrentLastDayQuality OBJECT-TYPE
              SYNTAX  INTEGER { normal(2), degraded(4) }
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
		" If the number of errors per 24 hours is superior to
		the atmNteDPLTCR value, the quality of service of
		the day is declared as degraded."
	DEFVAL { normal }
	::= { atmVcPMCurrentEntry 17 }


          -- the ATM VC Interval

          -- The ATM VC Interval Table contains various statistics
          -- collected by each ATM Interface/VC over the previous 24
          -- hours of operation.  The past 24 hours are broken into 96
          -- completed 15 minute intervals.

          atmVcIntervalTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF AtmVcIntervalEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "The ATM Vc Interval table."
              ::= { atmVcPerformance 3 }

          atmVcIntervalEntry OBJECT-TYPE
              SYNTAX  AtmVcIntervalEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "An entry in the ATM Vc Interval table."
              INDEX   { ifIndex, atmVcIntervalVpi, 
                        atmVcIntervalVci, atmVcIntervalNumber }
              ::= { atmVcIntervalTable 1 }

          AtmVcIntervalEntry ::=
              SEQUENCE {
	    atmVcIntervalVpi
	      Integer32,
	    atmVcIntervalVci
	      Integer32,
                  atmVcIntervalNumber
                      Integer32,
                  atmVcIntervalRxCellsClp01
                      Gauge32,
                  atmVcIntervalRxCellsClp0
                      Gauge32,
                  atmVcIntervalGcra0Violations
                      Gauge32,
                  atmVcIntervalGcra1Violations
                      Gauge32,
                  atmVcIntervalRxAIS
                      Gauge32,
                  atmVcIntervalTxAIS
                      Gauge32,
                  atmVcIntervalRxRDI
                      Gauge32,
                  atmVcIntervalTxRDI
                      Gauge32,
                  atmVcIntervalContinuityLoss
                      Gauge32,
                  atmVcIntervalUAS
                      Gauge32,
	              atmVcIntervalSES 
	                  Gauge32,
	              atmVcIntervalCDC
	                  Gauge32,
                  atmVcIntervalTotalDiscards     
                      Gauge32,
                  atmVcIntervalClp0Discards      
                      Gauge32,
                  atmVcIntervalTotalCellOuts     
                      Gauge32,
                  atmVcIntervalClp0CellOuts      
                      Gauge32,
                  atmVcIntervalTaggedOuts        
                      Gauge32,
	              atmVcIntervalPCR
	                  Gauge32,
	              atmVcIntervalSCR
	                  Gauge32,
	              atmVcIntervalMCR
	                  Gauge32,
                  atmVcIntervalShaperTotalDiscards     
                      Gauge32,
                  atmVcIntervalShaperClp0Discards      
                      Gauge32,
                  atmVcIntervalShaperClp1Discards      
                      Gauge32
          }

          atmVcIntervalVpi OBJECT-TYPE
              SYNTAX  Integer32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The VPI of the VCL."
              ::= { atmVcIntervalEntry 1 }

          atmVcIntervalVci OBJECT-TYPE
              SYNTAX  Integer32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The VCI of the VCL."
              ::= { atmVcIntervalEntry 2 }

          atmVcIntervalNumber OBJECT-TYPE
              SYNTAX  Integer32 (1..96)
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "A number between 1 and 96, where 1 is the most
                      recently completed 15 minute interval and 96 is
                      the least recently completed 15 minutes interval
                      (assuming that all 96 intervals are valid)."
              ::= { atmVcIntervalEntry 3 }

          atmVcIntervalRxCellsClp01 OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of transmitted 
                      cells , encountered by an ATM interface/VC in
                      one of the previous 96, individual 15 minute,
                      intervals."
              ::= { atmVcIntervalEntry 4 }

          atmVcIntervalRxCellsClp0 OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of received
                      cells, encountered by an ATM
                      interface/VC in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVcIntervalEntry 5 }

          atmVcIntervalGcra0Violations OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of
                      cells violating GCRA0, encountered by an ATM
                      interface/VC in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVcIntervalEntry 6 }

          atmVcIntervalGcra1Violations OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of
                      cells violating GCRA1, encountered by an ATM
                      interface/VC in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVcIntervalEntry 7 }

          atmVcIntervalRxAIS OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of received
                      AIS cells, encountered by an ATM
                      interface/VC in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVcIntervalEntry 8 }

          atmVcIntervalTxAIS OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of transmitted
                      AIS cells, encountered by an ATM
                      interface/VC in one of the previous 96, individual 15
                      minute, intervals. Not supported  in the first phase."
              ::= { atmVcIntervalEntry 9 }

          atmVcIntervalRxRDI OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of received
                      RDI cells, encountered by an ATM
                      interface/VC in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVcIntervalEntry 10 }

          atmVcIntervalTxRDI OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of transmitted
                      RDI cells, encountered by an ATM
                      interface/VC in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVcIntervalEntry 11 }

          atmVcIntervalContinuityLoss OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of Continuity
                      Loss cells, encountered by an ATM
                      interface/VC in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVcIntervalEntry 12 }

          atmVcIntervalUAS OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of Unavailable
                      Seconds, encountered by an ATM
                      interface/VC in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVcIntervalEntry 13 }

          atmVcIntervalSES OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of Severerly Errored
                      Seconds, encountered by an ATM
                      interface/VC in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVcIntervalEntry 14 }

	atmVcIntervalCDC OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "Amount of cells dropped in the 15 minute interval 
                       of the VC connection."
              ::= { atmVcIntervalEntry 15 }

    atmVcIntervalTotalDiscards OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of valid ATM cells discarded by
                      the traffic policing entity.  This includes cells
                      originally received with CLP=0 and CLP=1."
              ::= { atmVcIntervalEntry 16 }

    atmVcIntervalClp0Discards OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of valid ATM cells received with
                      CLP=0 an  discarded by the traffic policing
                      entity."
              ::= { atmVcIntervalEntry 17 }

    atmVcIntervalTotalCellOuts OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of valid ATM cells transmitted
                      by this VPL.  This includes both CLP=0 and CLP=1
                      cells."
              ::= { atmVcIntervalEntry 18 }
                        
                       
    atmVcIntervalClp0CellOuts OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of valid ATM cells transmitted
                      with CLP=0 by this VPL."
              ::= { atmVcIntervalEntry 19 }

    atmVcIntervalTaggedOuts OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of valid ATM cells tagged by the
                      traffic policing entity from CLP=0 to CLP=1 and
                      transmitted by this VPL."
              ::= { atmVcIntervalEntry 20 }
                        
	atmVcIntervalPCR OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The maximum traffic rate encountered in the 
                      last interval of the VC connection (monitored once a second)  
                      encountered by an ATM interface/VC in one of the previous 96, 
                      individual 15  minute, intervals."
              ::= { atmVcIntervalEntry 21 }

	atmVcIntervalSCR OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The average traffic rate during the last interval 
                      of the VC connection, encountered by an ATM interface/VC 
                      in one of the previous 96, individual 15 minute, intervals."
              ::= { atmVcIntervalEntry 22 }

	atmVcIntervalMCR OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "MCR - The minimum traffic rate encountered in the last 
                      interval of the VC connection (monitored once a second)  
                      encountered by an ATM interface/VC in one of the previous 96, 
                      individual 15 minute, intervals."
              ::= { atmVcIntervalEntry 23 }

    atmVcIntervalShaperTotalDiscards OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of cells (CLP0 and CLP1) discarded
                       due to congestion by the traffic shaper."
              ::= { atmVcIntervalEntry 24 }

    atmVcIntervalShaperClp0Discards OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of CLP0 cells discarded
                       due to congestion by the traffic shaper."
              ::= { atmVcIntervalEntry 25 }
    
    atmVcIntervalShaperClp1Discards OBJECT-TYPE
              SYNTAX       Gauge32
              MAX-ACCESS       read-only
              STATUS       current
              DESCRIPTION
                      "The total number of CLP1 cells discarded
                       due to congestion by the traffic shaper."
              ::= { atmVcIntervalEntry 26 }


          -- The ATM VC Interval Table for Performance Management
          -- which contains various statistics
          -- collected by each ATM Interface/VC over the previous 24
          -- hours of operation.  The past 24 hours are broken into 96
          -- completed 15 minute intervals.

          atmVcPMIntervalTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF AtmVcPMIntervalEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "The ATM Vc Interval table for Performance Management."
              ::= { atmVcPerformance 4 }

--atmCESAAL1StatsTable OBJECT IDENTIFIER ::= {atmVcPerformance 5} (see hybCES.txt)

          atmVcPMIntervalEntry OBJECT-TYPE
              SYNTAX  AtmVcPMIntervalEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "An entry in the ATM Vc Interval table for Performance
                       Management."
              INDEX   { ifIndex, atmVcPMIntervalVpi, 
                        atmVcPMIntervalVci, atmVcPMIntervalDir, atmVcPMIntervalNumber }
              ::= { atmVcPMIntervalTable 1 }

          AtmVcPMIntervalEntry ::=
              SEQUENCE {
	              atmVcPMIntervalVpi
	                  Integer32,
	              atmVcPMIntervalVci
	                  Integer32,
	              atmVcPMIntervalDir 
	                  INTEGER,
 	              atmVcPMIntervalNumber 
                      Integer32,
                  atmVcPMIntervalTxClp01
                      Gauge32,
                  atmVcPMIntervalTxClp0
                      Gauge32,
                  atmVcPMIntervalRxClp01
                      Gauge32,
                  atmVcPMIntervalRxClp0
                      Gauge32,
                  atmVcPMIntervalErroredCells
                      Gauge32,
                  atmVcPMIntervalLostCells
                      Gauge32,
                  atmVcPMIntervalMisinsertedCells
                      Gauge32,
                  atmVcPMIntervalECB
                      Gauge32,
                  atmVcPMIntervalSECB
                      Gauge32,
                  atmVcPMIntervalES
                      Gauge32,
                  atmVcPMIntervalSES
                      Gauge32,
                  atmVcPMIntervalUAS
                      Gauge32,
	    atmVcPMIntervalQuality
	        INTEGER,
	    atmVcPMIntervalLastDayQuality
	        INTEGER
              }

          atmVcPMIntervalVpi OBJECT-TYPE
              SYNTAX  Integer32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The VPI of the VCL."
              ::= { atmVcPMIntervalEntry 1 }

          atmVcPMIntervalVci OBJECT-TYPE
              SYNTAX  Integer32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The VCI of the VCL."
              ::= { atmVcPMIntervalEntry 2 }

          atmVcPMIntervalDir OBJECT-TYPE
              SYNTAX  INTEGER {forward(2),
			                   backward(3) }
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The direction of Performance Management."
              ::= { atmVcPMIntervalEntry 3 }

          atmVcPMIntervalNumber OBJECT-TYPE
              SYNTAX  Integer32 (1..96)
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "A number between 1 and 96, where 1 is the most
                      recently completed 15 minute interval and 96 is
                      the least recently completed 15 minutes interval
                      (assuming that all 96 intervals are valid)."
              ::= { atmVcPMIntervalEntry 4 }

          atmVcPMIntervalTxClp01 OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of transmitted
                      CLP 0+1 cells, encountered by an ATM
                      interface/VC in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVcPMIntervalEntry 5 }

          atmVcPMIntervalTxClp0 OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of transmitted
                      CLP 0 cells, encountered by an ATM
                      interface/VC in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVcPMIntervalEntry 6 }

          atmVcPMIntervalRxClp01 OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of received
                      CLP 0+1 cells, encountered by an ATM
                      interface/VC in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVcPMIntervalEntry 7 }

          atmVcPMIntervalRxClp0 OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of received
                      CLP 0 cells, encountered by an ATM
                      interface/VC in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVcPMIntervalEntry 8 }

          atmVcPMIntervalErroredCells OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of Errored
                      cells, encountered by an ATM
                      interface/VC in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVcPMIntervalEntry 9 }

          atmVcPMIntervalLostCells OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of Lost
                      cells, encountered by an ATM
                      interface/VC in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVcPMIntervalEntry 10 }

          atmVcPMIntervalMisinsertedCells OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of Misinserted
                      cells, encountered by an ATM
                      interface/VC in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVcPMIntervalEntry 11 }

          atmVcPMIntervalECB OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of ECBs
                      encountered by an ATM
                      interface/VC in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVcPMIntervalEntry 12 }

          atmVcPMIntervalSECB OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of SECBs
                      encountered by an ATM
                      interface/VC in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVcPMIntervalEntry 13 }

          atmVcPMIntervalES OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of Errored
                      Seconds, encountered by an ATM
                      interface/VC in one of the previous 96, individual 15
                      minute, intervals."
              ::= { atmVcPMIntervalEntry 14 }

          atmVcPMIntervalSES OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of Severely
                       Errored Seconds, encountered by an ATM
                       interface/VC in one of the previous 96, individual 15
                       minute, intervals."
              ::= { atmVcPMIntervalEntry 15 }

          atmVcPMIntervalUAS OBJECT-TYPE
              SYNTAX  Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter associated with the number of Unavailable
                       Seconds, encountered by an ATM
                       interface/VC in one of the previous 96, individual 15
                       minute, intervals."
              ::= { atmVcPMIntervalEntry 16 }

atmVcPMIntervalQuality OBJECT-TYPE
              		SYNTAX  INTEGER { normal(2), unacceptable(3) }
		MAX-ACCESS read-only
		STATUS current
		DESCRIPTION
		" If the number of errors per interval is superior to
		the atmNteUPLTCR value, the quality of service of
		the interval is declared as unacceptable."
		DEFVAL { normal }
	::= { atmVcPMIntervalEntry 17}

	    atmVcPMIntervalLastDayQuality OBJECT-TYPE
              		SYNTAX  INTEGER { normal(2), degraded(4) }
		MAX-ACCESS read-only
		STATUS current
		DESCRIPTION
		" If the number of errors per 24 hours is superior to
		the atmNteDPLTCR value, the quality of service of
		the day is declared as degraded."
		DEFVAL { normal }
	::= { atmVcPMIntervalEntry 18}




-- VC QoS Table

atmVcQoSTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF AtmVcQoSEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
        "The ATM VP QoS table."
    ::= { atmVcPerformance 6 }

atmVcQoSEntry OBJECT-TYPE
    SYNTAX  AtmVcQoSEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
        "An entry in the ATM VP table."
    INDEX   { ifIndex, atmVclVpi, atmVclVci, atmVcQoSPeriodRef }
    ::= { atmVcQoSTable 1 }

AtmVcQoSEntry ::=
    SEQUENCE {
	          atmVcQoSPeriodRef     INTEGER,
	          atmVcQoSElapsedTime	Integer32,
	          atmVcQoSUAS		    Gauge32
             }


atmVcQoSPeriodRef OBJECT-TYPE
	SYNTAX  INTEGER 
	      {
           currentPeriod  (1),
           lastPeriod     (2)
	      }
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION
	    "This object is an index that specifies which period of time, the next 
	     2 objects refer to.
	     currentPeriod  - the period since last systemResetAllStatsCmd received or
	                      since Start-up (if no systemResetAllStatsCmd was received since
	                      Start-up) until now.
	     lastPeriod    - the period between last two commands of systemResetAllStatsCmd.
	                     - If only one command occurred since Start-up: the period between 
	                       Start-up and last command.
	                     - If no command occurred since Start-up: this period will not 
	                       actually exist. In this case, he following 5 objects will be 0."
	::= { atmVcQoSEntry 1 }

atmVcQoSElapsedTime OBJECT-TYPE
	SYNTAX  Integer32 
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION
	    "Elapsed Time in seconds.
	     - for atmVcQoSPeriodRef = currentPeriod:
	       The period since last systemResetAllStatsCmd received or	since Start-up 
	       (if no systemResetAllStatsCmd was received since	Start-up) until now.
	     - for atmVcQoSPeriodRef = lastPeriod:
	       The value of atmVcQoSElapsedTime when last systemResetAllStatsCmd
	       was received."
	::= { atmVcQoSEntry 2 }

atmVcQoSUAS OBJECT-TYPE
	SYNTAX  Gauge32 
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION
	    "Number of Unavailable Seconds for the reference period (atmVcQoSPeriodRef)."
	::= { atmVcQoSEntry 3 }

-- VC PM QoS Table

atmVcPMQoSTable OBJECT-TYPE
     SYNTAX  SEQUENCE OF AtmVcPMQoSEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
         "The PM VC QoS table."
     ::= { atmVcPerformance 7 }

atmVcPMQoSEntry OBJECT-TYPE
     SYNTAX  AtmVcPMQoSEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
         "An entry in the VC PM QoS table."
     INDEX   { ifIndex, atmVclVpi, atmVclVci, atmVcPMQoSDirection ,atmVcPMQoSPeriodRef }
     ::= { atmVcPMQoSTable 1 }

AtmVcPMQoSEntry ::=
     SEQUENCE {
               atmVcPMQoSDirection	   INTEGER,
	           atmVcPMQoSPeriodRef	   INTEGER,
	           atmVcPMQoSCLR		   Gauge32,
	           atmVcPMQoSCER           Gauge32,
	           atmVcPMQoSCMR           Gauge32
              }

atmVcPMQoSDirection OBJECT-TYPE
     SYNTAX  INTEGER 
         {
          forward(2),
		  backward(3) 
		 }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
          "The direction of performance management."
      ::= { atmVcPMQoSEntry 1 }

atmVcPMQoSPeriodRef OBJECT-TYPE
	SYNTAX  INTEGER 
	      {
           currentPeriod  (1),
           lastPeriod     (2)
	      }
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION
	"This object is an index that specifies which period of time, the next
	 5 objects refer to.
	 currentPeriod - the period since last systemResetAllStatsCmd received or
	                 since Start-up (if no systemResetAllStatsCmd was received since
	                 Start-up) until now.
	 lastPeriod    - the period between last two commands of systemResetAllStatsCmd.
	                 - If only one command occurred since Start-up: the period between 
	                   Start-up and last command.
	                 - If no command occurred since Start-up: this period will not 
	                   actually exist. In this case, he following 5 objects will be 0."
	::= { atmVcPMQoSEntry 2 }


atmVcPMQoSCLR OBJECT-TYPE
	SYNTAX  Gauge32 
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION
	"Cell Loss Ratio counter for the reference period (atmVcPMQoSPeriodRef)- 
	defined in accordance with I.356 , in %.
	The value will be multipuled by 100."
	::= { atmVcPMQoSEntry 3 }

atmVcPMQoSCER OBJECT-TYPE
	SYNTAX  Gauge32 
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION
	"Cell Error Ratio counter for the reference period (atmVcPMQoSPeriodRef) 
	defined in accordance with I.356 , in %.
	The value will be multipuled by 100."
	::= { atmVcPMQoSEntry 4 }

atmVcPMQoSCMR OBJECT-TYPE
	SYNTAX  Gauge32 
	MAX-ACCESS  read-only
	STATUS  current
	DESCRIPTION
	"Cell Miss-insertion Ratio counter for the reference period (atmVcPMQoSPeriodRef) 
	defined in accordance with I.356 , cells/sec ."
	::= { atmVcPMQoSEntry 5 }

--VC Shaper Statistics Table
atmVcShaperStatTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF AtmVcShaperStatEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "The ATM VC shaper statistics table."
              ::= { atmVcPerformance 8 }

          atmVcShaperStatEntry OBJECT-TYPE
              SYNTAX  AtmVcShaperStatEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "An entry in the ATM VC shaper statistics table."
              INDEX   { ifIndex, atmVclVpi, atmVclVci }
              ::= { atmVcShaperStatTable 1 }

AtmVcShaperStatEntry ::=
     SEQUENCE {
	           atmVcShaperDiscarded          Counter32,
               atmVcShaperOccupation 		 Integer32,
               atmVcShaperMaxOccupation 	 Integer32,
               atmVcShaperLevel 			 INTEGER,
               atmVcShaperEpdDropped 		 Counter32,
               atmVcShaperTotalEpdDropped 	 Counter32
              }

atmVcShaperDiscarded  OBJECT-TYPE
              SYNTAX  Counter32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                   "The number of Cells that were discarded in the shaper on that VCC due 
                    to buffer overflow. This counter counts till it reaches its MAX value 
                    (20 bits) and then rolls over."
              ::= { atmVcShaperStatEntry 1 }

atmVcShaperOccupation OBJECT-TYPE
              SYNTAX  Integer32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                   "The number of Cells that are currently stored in the buffer.
                   This parameter is limited to 20 bits."
              ::= { atmVcShaperStatEntry 2}

atmVcShaperMaxOccupation OBJECT-TYPE
              SYNTAX  Integer32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                   "The Maximum number of Cells that were stored in the buffer, 
                   since this VC was activated.	This parameter is limited to 20 bits."
              ::= { atmVcShaperStatEntry 3}

atmVcShaperLevel OBJECT-TYPE
	          SYNTAX  INTEGER { 
	                 empty   (1), 
	                 full    (2), 
	                 below   (3),
	                 above   (4)
                 	} 
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                   "The occupation of the buffer according to a predefined threshold.
                   empty - buffer is Empty
                   full  - buffer is Full 
                   below - buffer is Below the threshold
                   above - buffer is Above the threshold. This is also the trigger to 
                   start EPD\PPD mechanism, if set for the VCC."
              ::= { atmVcShaperStatEntry 4}

atmVcShaperEpdDropped OBJECT-TYPE
              SYNTAX  Counter32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                   "The number of Cells that were dropped in the shaper on that VCC 
                   due to EPD\PPD mechanism in the last second.
                   This parameter is limited to 24 bits.
                   Applicable for a EPD/PPD VC only."
              ::= { atmVcShaperStatEntry 5}

atmVcShaperTotalEpdDropped OBJECT-TYPE
              SYNTAX  Counter32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                   "The Total number of Cells that were dropped in the shaper on that 
                   VPC due to EPD\PPD mechanism in the last 15 minutes. This counter 
                   automatically reset itself every 15 minutes.
                   Applicable for a EPD/PPD VC only."
              ::= { atmVcShaperStatEntry 6}



-- New
-- The agent will keep in this group the date & time corresponding to each interval.
atmIntervalDateTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF AtmIntervalDateEntry
	MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
	"The agent will keep in this group the date & time
	 corresponding to each interval."
             ::=  {atmPerfHistory 3}

 atmIntervalDateEntry OBJECT-TYPE
              SYNTAX AtmIntervalDateEntry 
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "The date & time for the given interval."
              INDEX   { atmIntervalDateInterval } 
              ::= { atmIntervalDateTable 1 }

         AtmIntervalDateEntry ::=
              SEQUENCE {
 		atmIntervalDateInterval 
                      		Integer32,
		atmIntervalDateDate
			DisplayString,
                  	atmIntervalDateTime
                      		DisplayString
	}

	atmIntervalDateInterval  OBJECT-TYPE
              		SYNTAX  Integer32 (1..96)
		MAX-ACCESS read-only
		STATUS current
		DESCRIPTION
		" The interval number defining this entry."
	::= { atmIntervalDateEntry 1}

	atmIntervalDateDate OBJECT-TYPE
              		SYNTAX DisplayString
		MAX-ACCESS read-only
		STATUS current
		DESCRIPTION
		"The date corresponding to this interval."
	::= { atmIntervalDateEntry 2}

	atmIntervalDateTime OBJECT-TYPE
              		SYNTAX DisplayString
		MAX-ACCESS read-only
		STATUS current
		DESCRIPTION
		"The time corresponding to this interval."
	::= { atmIntervalDateEntry 3}



--atmNte  OBJECT IDENTIFIER  ::=  {radAtm 3}

atmNteSys  OBJECT IDENTIFIER  ::=  {atmNte 1}

atmNteSysConfig  OBJECT IDENTIFIER  ::=  {atmNteSys 1}

          atmNteManagerTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF AtmNteManagerEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "The Manager Table includes all the NMSs that
                       receive traps from this agent. A single manager
                       can receive traps on more than one PVC. The agent 
                       will set	implicitly the correct ifIndex, VPI, VCI 
                       values to all relevant entries in the table when 
                       the user changes	them for one of the PVCs."
              ::= { atmNteSysConfig 1 }

          atmNteManagerEntry OBJECT-TYPE
              SYNTAX  AtmNteManagerEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "A single manager and the PVC for receiving traps."
              INDEX   { atmNteManagerIP, atmNteManagerPvc} 
              ::= { atmNteManagerTable 1 }

          AtmNteManagerEntry ::=
              SEQUENCE {
                  atmNteManagerIP
                      IpAddress,
				  atmNteManagerPvc
				      Integer32,
                  atmNteManagerIfIndex
                      Integer32,
                  atmNteManagerVpi
                      Integer32,
                  atmNteManagerVci
                      Integer32,
                  atmNteManagerTrapMask
                      Integer32,
                  atmNteManagerRowStatus
                      RowStatus,
                  atmNteManagerNextHop
                      IpAddress,
				  atmNteManagerVlanSupport
					  INTEGER,
				  atmNteManagerVlanIdentifier
					  Integer32,
				  atmNteManagerVlanFramePriority
					  Integer32,
				  atmNteManagerAlarmTrapMask
				  	  OCTET STRING,
				  atmNteManagerConfigPorts
					  Integer32
              }

          atmNteManagerIP OBJECT-TYPE
              SYNTAX  IpAddress 
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The IP address of the NMS."
              ::= { atmNteManagerEntry 1 }

          atmNteManagerPvc OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "A PVC index. The range is 1..8. There are four PVCs
                       on the User Port and four PVCs on the Network Port.
                       The default VPI, VCI values are specified below." 
              ::= { atmNteManagerEntry 2 }

          atmNteManagerIfIndex OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-create
              STATUS  current
              DESCRIPTION
                      "The ATM interface index of the management port."
              ::= { atmNteManagerEntry 3 }

          atmNteManagerVpi OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-create
              STATUS  current
              DESCRIPTION
                      "The VPI of the management VCL. Default: 0."
              ::= { atmNteManagerEntry 4 }

          atmNteManagerVci OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-create
              STATUS  current
              DESCRIPTION
                      "The VCI of the management VCL. Defaults: 32,33,34,35."
              ::= { atmNteManagerEntry 5 }

          atmNteManagerTrapMask OBJECT-TYPE
         	SYNTAX  Integer32 
        	MAX-ACCESS  read-create
        	STATUS current
        	DESCRIPTION
               "The value of this attribute determines the type of traps the 
                agent should mask and not send to this NMS. The 
                value is differently determined for different products. There are 
                mainly two methods:
              - an integer number, specifying the traps' severity.
              - a sum of 2**n, where n is a bit assigned to a certain 
                masked trap group.
                User should consult the product specification, to find out 
                the method employed."
        	::= { atmNteManagerEntry 6 }

    atmNteManagerRowStatus OBJECT-TYPE
              SYNTAX RowStatus 
              MAX-ACCESS read-create
              STATUS current
              DESCRIPTION
                 "Creation/Deletion of rows in the table."
              ::= {atmNteManagerEntry 7}

    atmNteManagerNextHop OBJECT-TYPE
              SYNTAX  IpAddress 
              MAX-ACCESS  read-create
              STATUS  current
              DESCRIPTION
                      "This parameter is relevant to Ethernet out of band 
                      host only (PVC=10).
                      The Next Hop IP address of the entry route."
              ::= { atmNteManagerEntry 8 }

    atmNteManagerVlanSupport OBJECT-TYPE
    		SYNTAX       INTEGER {
		    no		(2),
		    yes	    (3)
		    }
		    MAX-ACCESS  read-create
		    STATUS  current
		    DESCRIPTION
		    "VLAN support (Tagging).
		     no - No support to VLAN.
		     yes - 4 VLAN bytes will be added to the frame."
	    ::= { atmNteManagerEntry 9}

    atmNteManagerVlanIdentifier OBJECT-TYPE
 		  SYNTAX  Integer32 
 	      MAX-ACCESS  read-create
    	  STATUS  current
	      DESCRIPTION
    	  "VLAN ID. Range is 0..4095."
     	::= { atmNteManagerEntry 10 }
  
    atmNteManagerVlanFramePriority OBJECT-TYPE
	     SYNTAX  Integer32 
	     MAX-ACCESS  read-create
	     STATUS  current
	     DESCRIPTION
	     "VLAN Frame priority.Range is 0..7."
	     ::= { atmNteManagerEntry 11 }

    atmNteManagerAlarmTrapMask OBJECT-TYPE
       	 SYNTAX  OCTET STRING
         MAX-ACCESS  read-create
         STATUS current
         DESCRIPTION
         "The value of this object determines the alarm traps that the 
          agent should mask and not send to this NMS.
           
          The value is an Octet String, where each bit is assigned to a certain
          trap.
          If the bit = 1, the trap will be masked.
          If the bit = 0, the trap will not be masked.
          More details on the masked traps exist in the product specification.
		  
		  For products that do not mask specific traps, the value of the bits will be 0."
       	::= { atmNteManagerEntry 12 }

    atmNteManagerConfigPorts OBJECT-TYPE
	     SYNTAX  Integer32 
	     MAX-ACCESS  read-create
	     STATUS  current
	     DESCRIPTION
	     "This variable defines from which port/s this manager can configure the device.
		  For IPmux 11 the value of this variable will be according to the ports 
		  combination:
	      Network =1
	      User1=2
		  User2=4
		  (For Example: All ports = 7)."
	     ::= { atmNteManagerEntry 13 }



atmNteUPLTCR OBJECT-TYPE
              SYNTAX Integer32 
              MAX-ACCESS read-write
              STATUS current
              DESCRIPTION
                 "The Unacceptable ES Limit threshold for Performance Management."
              ::= {atmNteSysConfig 2}

atmNteDPLTCR OBJECT-TYPE
              SYNTAX Integer32 
              MAX-ACCESS read-write
              STATUS current
              DESCRIPTION
                 "The Degraded ES Limit threshold for Performance Management."
              ::= {atmNteSysConfig 3}

atmNteSysLogClearAll OBJECT-TYPE
              SYNTAX INTEGER { off(2), clear(3) }
              MAX-ACCESS read-write
              STATUS current
              DESCRIPTION
                 "Setting the variable to clear(3) removes all entries in the
	              Log Buffer of the agent. The agent will immediately reset 
	              the variable to off(2)."
              ::= {atmNteSysConfig 4}

atmNteUSESLTCR OBJECT-TYPE
              SYNTAX Integer32 
              MAX-ACCESS read-write
              STATUS current
              DESCRIPTION
	             "The Unacceptable SES Limit threshold for Performance Management."
              ::= {atmNteSysConfig 5}

atmNteDSESLTCR OBJECT-TYPE
              SYNTAX Integer32 
              MAX-ACCESS read-write
              STATUS current
              DESCRIPTION
                 "The Degraded ES Limit threshold for Performance Management."
              ::= {atmNteSysConfig 6}


atmNteProtection OBJECT IDENTIFIER  ::= { atmNteSysConfig  8 }

atmNteProtectionMode OBJECT-TYPE
               SYNTAX  INTEGER {
                          off       (1),
                          mspOn     (2),
						  pathOn    (3),
						  mspUniOn  (4),
						  mspOneToN (5)
                      }
               MAX-ACCESS  read-write
               STATUS  current
               DESCRIPTION
               "Protection  Mode.
               MspOn - Multiplex section protection. 
               pathOn - High order path protection.
               mspUniOn - Multiplex section Uni-directional protection.
               mspOneToN - Multiplex section protection."
               ::= { atmNteProtection 1 }

atmNteProtectionWorkingLink OBJECT-TYPE
               SYNTAX  INTEGER {
                          trunk1(2),
                          trunk2(3)
                      }
               MAX-ACCESS  read-write
               STATUS  current
               DESCRIPTION
               "Selects the working link when atmNteProtectionMode is off."
               ::= { atmNteProtection 2 }

atmNteProtectionSwitchLink OBJECT-TYPE
               SYNTAX  INTEGER {
                          off(1),
                          forceSwitch(2)
                      }
               MAX-ACCESS  read-write
               STATUS  current
               DESCRIPTION
               "ForceSwitch - will force Switching from the working link to the backup link. 
                Afterwards the agent will set atmNteProtectionSwitchLink back to off(1).
                atmNteProtectionMode must be either mspOn or pathOn."
               ::= { atmNteProtection 3 }

atmNteConfOam OBJECT IDENTIFIER  ::= { atmNteSysConfig  9 }

atmNteConfOamSupport OBJECT-TYPE
               SYNTAX  INTEGER {
                          intermediate(1),
                          segmentTermination(2),
                          endToEndTermination(3),
						  vpEndToEndVcSegment(4)
                      }
               MAX-ACCESS  read-write
               STATUS  current
               DESCRIPTION
               "OAM support  mode, which determines the device location
                in a segment wise."
               ::= { atmNteConfOam 1 }

atmNteConfOamTransmission OBJECT IDENTIFIER  ::= { atmNteConfOam  2 }

atmNteConfOamAIS OBJECT-TYPE
               SYNTAX  INTEGER {
                          none(1),
                          user(2),
                          network(3),
                          both(4)
                      }
               MAX-ACCESS  read-write
               STATUS  current
               DESCRIPTION
               "Defines if a F4 segment OAM cell is transmitted due 
                to problems in the other port, i.e. physical layer 
                alarm or F4 defect. This is valid only when the ACE101
                has ATM UNI interfaces in both sides and is configured
                for 'Non-Intrusive' mode.
                none - AIS is not sent to any of the ports.
                user - F4 AIS will be sent toward the user when defect 
                       is detected in the network port.
                network - F4 AIS will be sent toward the network when 
                          defect is detected in the user port.
                both - F4 AIS will be sent toward the network when defect
                       is detected in the user port and toward the user 
                       when defect is detected in the network port."
               ::= { atmNteConfOamTransmission 1 }

atmNteConfOamRDI OBJECT-TYPE
               SYNTAX  INTEGER {
                          none(1),
                          user(2),
                          network(3),
                          both(4)
                      }
               MAX-ACCESS  read-write
               STATUS  current
               DESCRIPTION
               "Defines if an F4 OAM RDI cell is transmitted due to
                physical layer problems in the port (in addition to 
                F4 RDI cells transmitted due to ATM layer problems).
                The type of F4 RDI (Segment or End-to-End) is according
                to the ACE-101 OAM mode.
                For example, If it is enabled for Network port, then 
                physical layer defect will initiate the transmission 
                of F4 RDI cell back to the trunk."
               ::= { atmNteConfOamTransmission 2 }

atmNteConfOamAddressing OBJECT IDENTIFIER  ::= { atmNteConfOam  3 }

atmNteConfLoopbackAddMode OBJECT-TYPE
             		SYNTAX INTEGER{
                          off(1),
                          on(2)
                      }
            	    MAX-ACCESS read-write
             		STATUS current
             		DESCRIPTION
                    	 "Loopback addressing mode.
                    	  on  - will enable  loopback addressing.
                    	  off - will disable loopback addressing."
             ::= { atmNteConfOamAddressing  1 }

atmNteConfLoopbackSourceAdd OBJECT-TYPE
             		SYNTAX OCTET STRING  (SIZE(2..20))
             		MAX-ACCESS read-write
             		STATUS current
             		DESCRIPTION
                    	 " Loopback source address. This field is relevant when 
                                atmNteConfOamAddMode is on."
             ::= { atmNteConfOamAddressing  2 }

--OAM Table
atmNteConfOamIfTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF AtmNteConfOamIfEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "OAM support per ATM interface."
               ::= { atmNteConfOam 4 }

atmNteConfOamIfEntry OBJECT-TYPE
              SYNTAX  AtmNteConfOamIfEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "."
              INDEX   { ifIndex } 
              ::= { atmNteConfOamIfTable 1 }

AtmNteConfOamIfEntry ::=
            SEQUENCE {
                atmNteConfOamIfAisRdi   INTEGER
			    }

     atmNteConfOamIfAisRdi OBJECT-TYPE
                SYNTAX  INTEGER {
                           off(1),
                           on (2)
                }
                MAX-ACCESS  read-write
                STATUS  current
                DESCRIPTION
                "This parameter controls the generation of F4/F5 
                AIS and RDI due to lower order problems such as physical
                layer problems.
                 
                For AIS: Defines if F4/F5 AIS cell is transmitted due
                 to problems such as physical layer alarm or F4/F5 defect. 
                 This is applicable for all  ports .
                 off - Problems in this port  will not trigger F4/F5 AIS
                       transmition to the ajacent port (e.g. from USER to 
                       NETWORK) of a VPC/VCC.
                 on  - Problems in this port will trigger F4/F5 AIS 
                       transmition to the ajacent port (e.g. from USER 
                       to NETWORK) of a VPC/VCC.                 
                 
                For RDI: Defines if F4/F5 RDI cell will be transmitted due to
                 physical layer problems in that port (in addition to
                 F4/F5 RDI cells transmitted due to ATM layer problems).
                 For example, If it is enabled for Network port, then
                 physical layer defect will initiate the transmission
                 of F4/F5 RDI cell back to the trunk.

                 The type of F4/F5 (Segment or End-to-End) is according
                 to the configuration of the VPC/VCC."
                 ::= { atmNteConfOamIfEntry 1 }


atmNteConfCAC OBJECT IDENTIFIER  ::= { atmNteSysConfig  10 }

atmNteConfCACMode OBJECT-TYPE
               SYNTAX  INTEGER {
 		disable(1),
		enable(2)
                }
               MAX-ACCESS  read-write
               STATUS  current
               DESCRIPTION
               "CAC support  mode. 

               For ACE2002, the following are the applicable values:
               disable(1), enable(2), 10 - 1000."
               ::= { atmNteConfCAC 1 }

atmNteHostIfTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF AtmNteHostIfEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "Host IP interface table."
              ::= { atmNteSysConfig 11 }

atmNteHostIfEntry OBJECT-TYPE
              SYNTAX  AtmNteHostIfEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "."
              INDEX   { atmNteHostPvcIndex } 
              ::= { atmNteHostIfTable 1 }

AtmNteHostIfEntry ::=
            SEQUENCE {
              atmNteHostPvcIndex
                    Integer32,
              atmNteHostIP
                    IpAddress,
              atmNteHostMask
                    IpAddress,
              atmNteHostAtmIfIndex
                    Integer32,
              atmNteHostVpi
                    Integer32,
              atmNteHostVci
                    Integer32,
              atmNteHostRowStatus
                    RowStatus,	
              atmNteHostRdnVpi
                    Integer32,
              atmNteHostRdnVci
                    Integer32,
			  atmNteHostDefaultNextHop
                    IpAddress,
			  atmNteHostVlanTagging
                    INTEGER,
			  atmNteHostDefaultVlanID
			  		Integer32,
			  atmNteHostDefaultVlanPriority
			  		Integer32
              }


atmNteHostPvcIndex OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "A PVC index. The range is 1..10."
              ::= { atmNteHostIfEntry 1 }

atmNteHostIP OBJECT-TYPE
              SYNTAX  IpAddress 
              MAX-ACCESS  read-create
              STATUS  current
              DESCRIPTION
                      "The host interface IP address."
              ::= { atmNteHostIfEntry 2 }

atmNteHostMask OBJECT-TYPE
              SYNTAX  IpAddress 
              MAX-ACCESS  read-create
              STATUS  current
              DESCRIPTION
                      "The host interface subnet mask."
              ::= { atmNteHostIfEntry 3 }

atmNteHostAtmIfIndex OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-create
              STATUS  current
              DESCRIPTION
                      "ATM interface index. Will be 1 
                       for user port, and 2 for network port."
              ::= { atmNteHostIfEntry 4 }

atmNteHostVpi OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-create
              STATUS  current
              DESCRIPTION
                      "VPI of the PVC connected to that host interface."
              ::= { atmNteHostIfEntry 5 }

atmNteHostVci OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-create
              STATUS  current
              DESCRIPTION
                      "VCI of the PVC connected to that host interface."
              ::= { atmNteHostIfEntry 6 }

atmNteHostRowStatus OBJECT-TYPE
              SYNTAX  RowStatus 
              MAX-ACCESS  read-create
              STATUS  current
              DESCRIPTION
                 "Creation/Deletion of rows in the table."
              ::= { atmNteHostIfEntry 7 }

atmNteHostRdnVpi OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-create
              STATUS  current
              DESCRIPTION
                      "The VPI of the redundant management VCL.
                      This parameter is applicable only if atmNteRdnManagement=enable(3). "
              ::= { atmNteHostIfEntry 8 }

atmNteHostRdnVci OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-create
              STATUS  current
              DESCRIPTION
                      "The VCI of the redundant management VCL.
                      This parameter is applicable only if atmNteRdnManagement=enable(3). "
              ::= { atmNteHostIfEntry 9 }

atmNteHostDefaultNextHop OBJECT-TYPE
              SYNTAX  IpAddress 
              MAX-ACCESS  read-create
              STATUS  current
              DESCRIPTION
                      "The host interface Default Next Hop address.
                       This address will be used as default next hop for 
                       every Bundle mapped to this Host."
              ::= { atmNteHostIfEntry 10 }

atmNteHostVlanTagging OBJECT-TYPE
              SYNTAX  INTEGER {
 			       		no		(2),
			       		yes		(3)
			       		}
 
              MAX-ACCESS  read-create
              STATUS  current
              DESCRIPTION
                      "VLAN Tag support.
       				   no - No support to VLAN.
       				   yes - 4 VLAN bytes will be added 
       				   to each frame connected to this Host."
              ::= { atmNteHostIfEntry 11 }

atmNteHostDefaultVlanID OBJECT-TYPE
       SYNTAX  Integer32 
       MAX-ACCESS  read-create
       STATUS  current
       DESCRIPTION
       "Default VLAN ID of this Host."
       ::= { atmNteHostIfEntry 12 }
  
atmNteHostDefaultVlanPriority OBJECT-TYPE
       SYNTAX  Integer32 
       MAX-ACCESS  read-create
       STATUS  current
       DESCRIPTION
       "Default VLAN priority for this Host."
       ::= { atmNteHostIfEntry 13 }


atmNteShaperMode OBJECT-TYPE
               SYNTAX  INTEGER {
 		         normal		(1),
		         group		(2),
		         aggregate	(3),
				 vpInbandMng (4)
                }
               MAX-ACCESS  read-write
               STATUS  current
               DESCRIPTION
               "Shaper Mode.
               vpInbandMng - Vcc within a Vp for management."
               ::= { atmNteSysConfig 12 }


atmNteOutputRate OBJECT-TYPE
               SYNTAX  Integer32
               MAX-ACCESS  read-write
               STATUS  current
               DESCRIPTION
               "Aggregate shaping output rate in Cells per Seconds units.
               Default value is the Network port rate."
               ::= { atmNteSysConfig 13 }

atmNteTosMode OBJECT-TYPE
               SYNTAX  INTEGER {
 		         notApplicable   (1),
		         disable		 (2),
		         enable	         (3)
                }
               MAX-ACCESS  read-write
               STATUS  current
               DESCRIPTION
               "TOS Mode."
               ::= { atmNteSysConfig 14 }

atmNteTosMask OBJECT-TYPE
               SYNTAX  OCTET STRING	(SIZE(1))
               MAX-ACCESS  read-write
               STATUS  current
               DESCRIPTION
               "This parameter determines the seqence of bits that will be used for TOS.
               For ACE101 this parameter is applicable only if atmNteTosMode = enable.
               Valid only for IP-TOS process."
               ::= { atmNteSysConfig 15 }

atmNteTosHighPriority OBJECT-TYPE
               SYNTAX  OCTET STRING (SIZE(8))
               MAX-ACCESS  read-write
               STATUS  current
               DESCRIPTION
               "Priorities options are High or Low.
			   High priority will be represented by bit = 1.
			   Low  priority will be represented by bit = 0.
			   Each TOS value will be represented by the bit location.
			   For example, the string for TOS 2, 9, 15 with High priority,
			   will be:
			   
			   |0000 0000|... ...|0000 0000|1000 0010|0000 0100| 
												...98 7654 3210	  (Bit  #)
																  
					8	   ...		  3			2		  1		  (Byte #)."
               ::= { atmNteSysConfig 16 }

atmNtePlugAndPlayActivity OBJECT-TYPE
               SYNTAX  INTEGER {
 		         disable   (1),
		         offline   (2),
		         online	   (3)
                }
               MAX-ACCESS  read-write
               STATUS  current
               DESCRIPTION
               "Activity control for Manager Plug And Play.
               disable - disable the feature.
               offline - Automatic learn IP address into offline memory.
               online  - Automatic learn IP address into online memory. "
               ::= { atmNteSysConfig 17 }

atmNteSlotUsage OBJECT-TYPE
               SYNTAX  INTEGER {
 		         notApplicable   (1),
		         user		     (2),
		         network	     (3)
                }
               MAX-ACCESS  read-write
               STATUS  current
               DESCRIPTION
               "Applicable to ace2002. Slot 2 might be configured
               as user slot or as network slot."
               ::= { atmNteSysConfig 18 }

atmNteConnectionsMaxNumber OBJECT-TYPE
               SYNTAX  INTEGER {
                       notApplicable(1),
                       max1024      (2),
                       max2048      (3)
               }
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION
                      "The MAX number of connections supported by system.
                       Setting this parameter will affect the number of MAX intervals supported.
                       This parameter will affect the system only after reset.
					   Changing this parameter from high value to a low value, will be accepted by agent
					   only if the actual used connection <= the desired connection Max number.
                       Applicable to ace2002. "
              ::= { atmNteSysConfig 19 }

atmNteDefaultVpi OBJECT-TYPE
               SYNTAX  Integer32
               MAX-ACCESS  read-write
               STATUS  current
               DESCRIPTION
                       "Default Vpi for management."
              ::= { atmNteSysConfig 20 }

atmNteDefaultVci OBJECT-TYPE
               SYNTAX  Integer32 
               MAX-ACCESS  read-write
               STATUS  current
               DESCRIPTION
               "Default Vci for management."
               ::= { atmNteSysConfig 21 }

atmNteReservedVpi    OBJECT-TYPE
              SYNTAX    Integer32  (0..255)
              MAX-ACCESS    read-write
              STATUS    current
              DESCRIPTION
                   "Internal use VPI, where shaperMode=vpInbandMng."
              ::= { atmNteSysConfig 22 }

atmNteRdnManagement OBJECT-TYPE
                SYNTAX  INTEGER {
                      disabled (2),
                      enabled  (3)
                 }
                MAX-ACCESS  read-only
                STATUS  current
                DESCRIPTION
                "The redundancy management status."
              ::= { atmNteSysConfig 23 }

atmNtePlugAndPlayIfIndex OBJECT-TYPE
                SYNTAX  InterfaceIndex
                MAX-ACCESS  read-write
                STATUS  current
                DESCRIPTION
                "The ifIndex of the Plug and Play VCC."
              ::= { atmNteSysConfig 24 }

atmNteLoopbackTimeout OBJECT-TYPE
                SYNTAX  Integer32
                MAX-ACCESS  read-write
                STATUS  current
                DESCRIPTION
                "The Loopback state timeout in minutes. A value of 
                zero means no timeout (for ever). Default is 5 min."
              ::= { atmNteSysConfig 25 }

atmNteOamTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF AtmNteOamEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
    "This table is a static table, which is created by agent once
	upon initialization. The created entries are actually, only the
	supported OAM features. 
	This table enables addition of new features by adding new entries
	rather than adding scalar parameters.
    An OAM feature is defined by the indexes values combination."
              ::= { atmNteSysConfig 26 }

atmNteOamEntry OBJECT-TYPE
    SYNTAX  AtmNteOamEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
    "An entry in the OAM table.
     Each entry in this table will indicate a special OAM." 
    INDEX {atmNteOamMode, atmNteOamCellType, atmNteOamLevel}
    ::= { atmNteOamTable 1 }

AtmNteOamEntry ::=
    SEQUENCE {
    atmNteOamMode
    INTEGER,
    atmNteOamCellType
    INTEGER,
	atmNteOamLevel
	INTEGER,
	atmNteOamEnable
	INTEGER
    }

atmNteOamMode OBJECT-TYPE
    SYNTAX  INTEGER
    {
     endToEnd  (1)
    }
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
    "The OAM cell path.
    endToEnd(1) - the entire path."
    ::= { atmNteOamEntry 1 }

atmNteOamCellType OBJECT-TYPE
    SYNTAX  INTEGER
    {
     aisAndRdi (1),
	 loopback  (2)
    }
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
    "This object indicates a unique Indication Signal.
     aisAndRdi(1) - Alarm Indication Signal (AIS) and 
                     Remote Defect Indication (RDI) cell.
     loopback(2) - Loopback cell."
    ::= { atmNteOamEntry 2 }

atmNteOamLevel OBJECT-TYPE
    SYNTAX  INTEGER
    {
--	 f4 (2),
	 f5 (3)
    }
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
    "The level of the OAM cell.
--    	 f4 (2) - VP level,
	     f5 (3)	- VC level."
    ::= { atmNteOamEntry 3 }

atmNteOamEnable OBJECT-TYPE
    SYNTAX  INTEGER
    {
     disable      (2),
	 enable       (3)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "This parameter determines if the specified OAM cells 
    will be enabled."
    ::= { atmNteOamEntry 4 }


atmNteDefaultLoopbackThreshold OBJECT-TYPE
                SYNTAX  Integer32
                MAX-ACCESS  read-write
                STATUS  current
                DESCRIPTION
                "The Default OAM Loopback Failure Threshold value 
                that will be used for configuration."
              ::= { atmNteSysConfig 27 }

atmNteMaxBurstSize OBJECT-TYPE
                SYNTAX  Integer32
                MAX-ACCESS  read-write
                STATUS  current
                DESCRIPTION
                "The Maximum allowed burst size (cell units).
                This object is applicable for each Physical port."
              ::= { atmNteSysConfig 28 }

atmNteGranularityFactor OBJECT-TYPE
                SYNTAX  Integer32
                MAX-ACCESS  read-write
                STATUS  current
                DESCRIPTION
                "This parameter affects the granularity of the guaranteed 
                Rate (SCR+MCR) in spaced connection (cell/sec units). 
                It is also defines the minimum guaranteed rate in spaced 
                connection."
              ::= { atmNteSysConfig 29 }


atmNteTotalInputRate OBJECT-TYPE
                SYNTAX  Integer32
                MAX-ACCESS  read-only
                STATUS  current
                DESCRIPTION
                "This parameter indicates the total input rate of the 
                device in cells/sec."
              ::= { atmNteSysConfig 30 }

atmNteTotalOutputRate OBJECT-TYPE
                SYNTAX  Integer32
                MAX-ACCESS  read-only
                STATUS  current
                DESCRIPTION
                "This parameter indicates the total output rate of the 
                device in cells/sec."
              ::= { atmNteSysConfig 31 }

atmAlarmForwardingTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF AtmAlarmForwardingEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "The Alarm Forwarding Mechanism will be operated 
                      for this table entries."
              ::= { atmNteSysConfig 32 }

          atmAlarmForwardingEntry OBJECT-TYPE
              SYNTAX  AtmAlarmForwardingEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "Each entry in this table is a pair of ports that
                      the Alarm Forwarding Mechanism is determined for."
              INDEX   { atmAlarmForwardingFailPort, atmAlarmForwardingToPort }
              ::= { atmAlarmForwardingTable 1 }

          AtmAlarmForwardingEntry ::=
              SEQUENCE {
	              atmAlarmForwardingFailPort
	                  Integer32,
                  atmAlarmForwardingToPort
                      Integer32,
                  atmAlarmForwardingRowStatus
                      RowStatus,
                  atmAlarmForwardingFailureLevel
                      BITS, 
                  atmAlarmForwardingRecoveryMode
                      INTEGER, 
                  atmAlarmForwardingRecoveryCommand
                      INTEGER,
                  atmAlarmForwardingTimeFilterWindow
                  	  Unsigned32 
              }

          atmAlarmForwardingFailPort OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "An Index of the port on which a fail occurs."
              ::= { atmAlarmForwardingEntry 1 }

          atmAlarmForwardingToPort OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "An Index of the port that will be affected 
                      upon the failure of the atmAlarmForwardingFailPort."
              ::= { atmAlarmForwardingEntry 2 }

          atmAlarmForwardingRowStatus OBJECT-TYPE
              SYNTAX  RowStatus 
              MAX-ACCESS  read-create
              STATUS  current
              DESCRIPTION
                      "Creation/Deletion of rows in the table."
              ::= { atmAlarmForwardingEntry 3 }

          atmAlarmForwardingFailureLevel OBJECT-TYPE
              SYNTAX  BITS{
			  physical (0),
			  atm      (1)
              } 
              MAX-ACCESS  read-create
              STATUS  current
              DESCRIPTION
                      "This parameter determines the level of failure 
                      that will operate the Alarm Forwarding Mechanism."
              ::= { atmAlarmForwardingEntry 4 }

          atmAlarmForwardingRecoveryMode OBJECT-TYPE
              SYNTAX  INTEGER {
			  manual     (1),
			  automatic  (2)
              } 
              MAX-ACCESS  read-create
              STATUS  current
              DESCRIPTION
                      "This parameter determines the Recovery Mode. 
                      manual - The user should stop the RDI transmission 
                               by using the atmAlarmForwardingRecoveryCommand.
                      automatic - The RDI transmission will be automatically 
                                  stopped upon atmAlarmForwardingFailPort
                                  recovery."
              ::= { atmAlarmForwardingEntry 5 }

          atmAlarmForwardingRecoveryCommand OBJECT-TYPE
              SYNTAX  INTEGER {
			  off   (2),
			  on    (3)
              } 
              MAX-ACCESS  read-create
              STATUS  current
              DESCRIPTION
                      "This parameter is a command. It is applicable when 
                      atmAlarmForwardingRecoveryMode = manual.
                      
                      on - Will stop the RDI transmission. After setting to 'On'
                           the agent will set this parameter back to 'Off'."
              ::= { atmAlarmForwardingEntry 6 }

          atmAlarmForwardingTimeFilterWindow OBJECT-TYPE
              SYNTAX  Unsigned32 
              MAX-ACCESS  read-create
              STATUS  current
              DESCRIPTION
                      "This parameter determines the Time Filter Window, meaning:
                       how much time (in seconds) should the alarm exist
                       in order to start the Alarm Forwarding operation."
              ::= { atmAlarmForwardingEntry 7 }


atmSysConfigCellTest OBJECT IDENTIFIER  ::= { atmNteSysConfig 33 }

          atmSysConfigCellTestPort OBJECT-TYPE
              SYNTAX  InterfaceIndex 
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION
                      "An Index of the port on which the cell test
                      will be sent."
              ::= { atmSysConfigCellTest 1 }

          atmSysConfigCellTestVpi OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION
                      "The VPI on which the cell test will be sent."
              ::= { atmSysConfigCellTest 2 }

          atmSysConfigCellTestVci OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION
                      "The VCI on which the cell test will be sent."
              ::= { atmSysConfigCellTest 3 }
 
          atmSysConfigCellTestPti OBJECT-TYPE
              SYNTAX  INTEGER {
		              user	(1), 
		              oamSegment		(2),
		              oamEndToEnd		(3)
					  }
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION
                      "The cell type."
              ::= { atmSysConfigCellTest 4 }

          atmSysConfigCellTestClp OBJECT-TYPE
              SYNTAX  INTEGER {
		              clp0	(1), 
		              clp1	(2)
					  }
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION
                      "The type of the Cell."
              ::= { atmSysConfigCellTest 5 }

          atmSysConfigCellTestOamType OBJECT-TYPE
              SYNTAX  INTEGER {
		              ais	(1), 
		              rdi	(2),
		              cc	(3),
					  lb    (4)
					  }
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION
                      "The OAM type of the Cell. This object is applicable 
                      if atmSysConfigCellTestPti = oamSegment/oamEndToEnd ."
              ::= { atmSysConfigCellTest 6 }

          atmSysConfigCellTestPayload OBJECT-TYPE
              SYNTAX  OCTET STRING (SIZE(1)) 
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION
                      "The payload of the cell. For OAM cell the payload
                      is set automatically to 6A."
              ::= { atmSysConfigCellTest 7 }
 
          atmSysConfigCellTestQuantity OBJECT-TYPE
              SYNTAX  Integer32 (1..10000) 
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION
                      "Quantity of cells to send."
              ::= { atmSysConfigCellTest 8 }

          atmSysConfigCellTestSendCmd OBJECT-TYPE
              SYNTAX  INTEGER {
		              off	(2), 
		              send	(3)
					  }
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION
                      "Setting the variable to send(3) perfroms cell test.
                       The agent will immediately reset the variable to off(2)."
              ::= { atmSysConfigCellTest 9 }



--  The ATM VP Cross Connect Extension Table

atmVpCrossConnectExtenTable OBJECT-TYPE
	SYNTAX         SEQUENCE OF AtmVpCrossConnectExtenEntry
	MAX-ACCESS     not-accessible
	STATUS         current
	DESCRIPTION
		"An extension to the ATM VP Cross Connect table
		 (RFC2515 - atmVpCrossConnectTable)."
	::= { atmNteSysConfig 34 }

atmVpCrossConnectExtenEntry OBJECT-TYPE
	SYNTAX         AtmVpCrossConnectExtenEntry
	MAX-ACCESS     not-accessible
	STATUS         current
	DESCRIPTION
		"An entry in the table."
	AUGMENTS    { atmVpCrossConnectEntry }  
	::= { atmVpCrossConnectExtenTable 1 }

AtmVpCrossConnectExtenEntry ::= SEQUENCE {
	atmVpCrossConnectName          SnmpAdminString
	}

atmVpCrossConnectName OBJECT-TYPE
	SYNTAX         SnmpAdminString (SIZE (1..64))
	MAX-ACCESS     read-create
	STATUS         current
	DESCRIPTION
		"The Connection's name."
	::= { atmVpCrossConnectExtenEntry 1 }

  
--  The ATM VC Cross Connect Extension Table

atmVcCrossConnectExtenTable OBJECT-TYPE
	SYNTAX         SEQUENCE OF AtmVcCrossConnectExtenEntry
	MAX-ACCESS     not-accessible
	STATUS         current
	DESCRIPTION
		"An extension to the ATM VC Cross Connect table
		 (RFC2515 - atmVcCrossConnectTable)."
	::= { atmNteSysConfig 35 }

atmVcCrossConnectExtenEntry OBJECT-TYPE
	SYNTAX         AtmVcCrossConnectExtenEntry
	MAX-ACCESS     not-accessible
	STATUS         current
	DESCRIPTION
		"An entry in the table."
	AUGMENTS    { atmVcCrossConnectEntry }  
	::= { atmVcCrossConnectExtenTable 1 }

AtmVcCrossConnectExtenEntry ::= SEQUENCE {
	atmVcCrossConnectName          SnmpAdminString
	}

atmVcCrossConnectName OBJECT-TYPE
	SYNTAX         SnmpAdminString (SIZE (1..64))
	MAX-ACCESS     read-create
	STATUS         current
	DESCRIPTION
		"The Connection's name."
	::= { atmVcCrossConnectExtenEntry 1 }


--  The Congestion Thresholds Configuration Table

atmCongestionThresholdTable OBJECT-TYPE
	SYNTAX         SEQUENCE OF AtmCongestionThresholdEntry
	MAX-ACCESS     not-accessible
	STATUS         current
	DESCRIPTION
		"The Congestion Thresholds Configuration Table."
	::= { atmNteSysConfig 36 }

atmCongestionThresholdEntry OBJECT-TYPE
	SYNTAX         AtmCongestionThresholdEntry
	MAX-ACCESS     not-accessible
	STATUS         current
	DESCRIPTION
		"An entry in the table."
	INDEX { atmCongestionThresholdType, atmCongestionThresholdServiceCategory }  
	::= { atmCongestionThresholdTable 1 }

AtmCongestionThresholdEntry ::= SEQUENCE {
	atmCongestionThresholdType         		INTEGER,
	atmCongestionThresholdServiceCategory	INTEGER,
	atmCongestionThresholdValue				Integer32
	}

atmCongestionThresholdType OBJECT-TYPE
	SYNTAX         INTEGER
		{
			global		(1),
			clp01		(2),
			clp1Upper	(3),
			clp1Lower	(4)
		}
	MAX-ACCESS     not-accessible
	STATUS         current
	DESCRIPTION
	"The Congestion Threshold Type."
	::= { atmCongestionThresholdEntry 1 }

atmCongestionThresholdServiceCategory OBJECT-TYPE
	SYNTAX         INTEGER
		{
			cbr		(1),
			rtVbr	(2),
			ubrPlus	(3),
			ubr		(4)
		}
	MAX-ACCESS     not-accessible
	STATUS         current
	DESCRIPTION
		"The Congestion Threshold Service Category."
	::= { atmCongestionThresholdEntry 2 }

atmCongestionThresholdValue OBJECT-TYPE
	SYNTAX         Integer32
	MAX-ACCESS     read-write
	STATUS         current
	DESCRIPTION
		"The Congestion Threshold Value."
	::= { atmCongestionThresholdEntry 3 }


atmNteQosMode OBJECT-TYPE
    SYNTAX  INTEGER {
		disable		(1),
		multipleVc	(2),
		singleVc	(3)		 
            }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"This variable defines the QoS Mode.
	 disable(1)		- QoS is disabled.
	 multipleVc(2)	- QoS is enabled and
	 				  multiple VCs can be bound per bridge port.
	 singleVc(3)	- QoS is enabled and
	 				  only single VC can be bound per bridge port."
   ::= { atmNteSysConfig 37 }

      
atmNteSysInfo  OBJECT IDENTIFIER  ::=  {atmNteSys 2}

          atmNteIdTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF AtmNteIdEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "The IDs of the cards and of the system."
              ::= { atmNteSysInfo 1 }

          atmNteIdEntry OBJECT-TYPE
              SYNTAX  AtmNteIdEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "."
              INDEX   { atmNteIdIndex}
              ::= { atmNteIdTable 1 }

          AtmNteIdEntry ::=
              SEQUENCE {
	              atmNteIdIndex
	                  Integer32,
                  atmNteUnitId
                      Integer32,
                  atmNteUnitVersion
                      DisplayString,
                  atmNteCardType
                      INTEGER, 
                  atmNteCardStatus
                      INTEGER, 
                  atmNteCardCmd
                      INTEGER,
                  atmNteProgCardType
                      INTEGER 
              }

          atmNteIdIndex OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "An Index of the Unit ID table.
                       The following units have IDs in this table:
                       1 - System
                       2 - ATM Board
                       3 - User Card
                       4 - Trunk 1 card
                       5 - Trunk 2 card
	                   6 - Shaper
                       7 - Clock Unit
                       8 -  Slot 1 card
                       9 -  Slot 2 card
                       10 - Slot 3 card
                       11 - Slot 4 card
                       12 - Fan1
                       13 - Fan2
                       14 - Control Unit."
              ::= { atmNteIdEntry 1 }

          atmNteUnitId OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The ID of the Unit. 
                      For index = 6, the id will describe the validity
                       of a shaper in the system: 0 - Shaper Not exist
                                                  1 - Shaper exist.
                      For index = 7, the id will describe the validity
                       of a clock in the system: 0 - Clock Not exist
                                                  1 - Clock exist.
												  2- Clock exist but failed.
                      For index = 12,13 the id will describe the functionality
                       of a FAN1 : 0 - OK
                                  1 - Failed."
              ::= { atmNteIdEntry 2 }

         atmNteUnitVersion OBJECT-TYPE
              SYNTAX DisplayString 
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "Hardware and Software version
                       of the module."
              ::= { atmNteIdEntry 3 }

       atmNteCardType OBJECT-TYPE
              SYNTAX  INTEGER {
		notApplicable	(1), 
		sc13mR155		(2),
		st13sR155		(3),
		st13lR155		(4),
		utpR155			(5),
		cxBncR155		(6),
		e3				(7),
		t3				(8),
		e1				(9),
		e1Ltu			(10),
		fc13lR155		(11),
		fc13lhR155		(12),
		fc15lhR155		(13),
		fc13lE3		    (14),
		fc13lhE3		(15),
		fc15lhE3		(16),
		fc13lT3		    (17),
		fc13lhT3		(18),
		fc15lhT3		(19),
		t1				(20),
		eth				(21),
		ethE1CesBnc	    (22),
		ethE1CesRj45    (23),
		ethT1CesRj45	(24),
		e1CesRj45		(25),
		e1CesBnc		(26),
		t1CesRj45		(27),
		e14Ces			(28),
 		e14CesRj45  	(29),
		t14CesRj45  	(30),

		hdlc4port		(31),
		hdlcE14CesBnc   (32),
		hdlcE14CesRj45  (33),
		hdlcT14CesRj45  (34),
		e1Rj45	  		(35),
		e1Bnc			(36),

		ethE14CesBnc	(37),
		ethE14CesRj45   (38),
		ethT14CesRj45   (39),

		hdlc1portHssi	   (40),
		hdlcHssiE14CesBnc  (41),
		hdlcHssiE14CesRj45 (42),
		hdlcHssiT14CesRj45 (43),

		e14ImaRj45	    (44),
		e14ImaBnc		(45),
		t14ImaRj45	    (46),

		ethE3CesBnc     (47),
		ethT3CesBnc	    (48),

		smSf1R155		(49),
		smSf2R155		(50),

        sc13sR155		(51),
        sc13lR155		(52),

		utp25			(53),

        sc13lhR155		(54),
        sc15lhR155		(55),

        sc13ljR155		(56),
        sc13lhjR155  	(57),
        sc15lhjR155  	(58),

		e18Ces 	        (59),
		e18CesRj45      (60),
		t18CesRj45      (61),

        sc13mR622       (62),
--        st13sR622       (63),
--        st13lR622       (64),
--        utpR622         (65),
--        cxBncR622       (66),
--        fc13lR622       (67),
--        fc13lhR622      (68),
--        fc15lhR622      (69),
--        smSf1R622       (70),
--        smSf2R622       (71),
--        sc13sR622       (72),
        sc13lR622       (73),
        sc13lhR622      (74),
        sc15lhR622      (75),
        
        fr4Port         (76),
		t3j				(77),
        fr1Port         (78),
        hdlc1Port       (79),

		sc13mR155D		(80),
        sc13lR155D		(81),
		fc13lR155D		(82),
		st13lR155D		(83),
        sc13lhR155D  	(84),
		fc13lhR155D		(85),
		st13lhR155D		(86),

		e18ImaBnc		(87),
		e18ImaRj45	    (88),
		t18ImaRj45	    (89),

		lanUtpE		    (90),
		lanLc13lE	    (91),
		lanLc13mE	    (92),

		e14ImaRj45CfgMode  (93),
		e14ImaBncCfgMode   (94),
		t14ImaRj45CfgMode  (95),

		sc13mR155R		(96),  --Dual for Redundancy
        sc13lR155R		(97),  --Dual for Redundancy
		fc13lR155R		(98),  --Dual for Redundancy
		st13lR155R		(99),  --Dual for Redundancy
        sc13lhR155R  	(100), --Dual for Redundancy
		fc13lhR155R		(101), --Dual for Redundancy
		st13lhR155R		(102), --Dual for Redundancy

		fEthUtpD		(103),
		fEthSmD	        (104),
		fEthMmD	        (105),

 		e14CesRj45Unbal (106),

		sc13mR155n		(107),
		sc13lR155n		(108),
		sc13lhR155n		(109),
		sc15lhR155n		(110),
		fc13lR155n		(111),
		fc13lhR155n		(112),
		fc15lhR155n		(113),
		st13lR155n		(114),

		lanUtp		    (115),
		lanLc13l	    (116),
		lanLc13m	    (117),

		e1FrHdlc		(118),
		e1FrHdlcUnbal	(119),
		t1FrHdlc	    (120),

	    channelizedT3   (121),	--for IP-MUX16

		fc15lhR155D		(122), --Dual STM-1
        sc15lhR155D		(123), --Dual STM-1
		smSf1R155D		(124), --Dual STM-1
		smSf2R155D		(125), --Dual STM-1
		smSf3R155D		(126), --Dual STM-1

		fc15lhR155R		(127), --Dual for Redundancy
		sc15lhR155R		(128), --Dual for Redundancy
        smSf1R155R  	(129), --Dual for Redundancy
		smSf2R155R		(130), --Dual for Redundancy
		smSf3R155R		(131), --Dual for Redundancy

		st13lhR155n		(132), --New STM-1
		smSf1R155n		(133), --New STM-1
		smSf2R155n		(134), --New STM-1
		smSf3R155n		(135), --New STM-1

		t18CesNg		(136), 
		e18CesUnbalNg	(137), 
		e18CesBalNg	    (138), 
		t14CesNg		(139), 
		e14CesUnbalNg	(140), 
		e14CesBalNg	    (141), 

		t18ImaUniNg		(142), 
		e18ImaUniUnbalNg(143), 
		e18ImaUniBalNg  (144), 
		t14ImaUniNg		(145), 
		e14ImaUniUnbalNg(146), 
		e14ImaUniBalNg  (147), 

        t1Ces           (148),
		e1CesUnbal      (149),
		e1CesBal        (150),

		switchedLan		(151), --LAN card with ETH switch (usually 4 ports)
		channelizedSts1  (152),	--Channelized STS1 card (for IP-MUX16)
		
		st13mR155		(153),
		st13lhR155		(154),
		st15lhR155		(155),

		gigabitEthUtp	(156),
		gigabitEthSfp	(157),
		fastEthUtp		(158),

		main			(251),
		control			(252),
		fan				(253),
		unknown			(254),
		empty			(255)

		-- values 1000 and up are reserved
		-- (used by atmNteProgCardType)
	}

              MAX-ACCESS  read-only
              STATUS current 
              DESCRIPTION
                      "The card type."
              ::= { atmNteIdEntry 4 }

         atmNteCardStatus OBJECT-TYPE
              SYNTAX  INTEGER {
                notApplicable       (1),
                notActive           (2),
				active				(3),
				inProgress		    (4),
				empty               (5)
	          }
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "Status of the card in the selected slot.
                       
                       notActive   -  Connections are in NotReady state. No configuration is 
                                      available for the card. The access to the card HW is blocked.
                                      This state is relevant for an extracted card,	and for a case 
                                      in which the card was deactivated.
				       active	   -  The module installed and functions. A card that in this state 
				                      can be configured.
				       inProgress  -  The status during proccessing of a command from atmNteCardCmd.
				       empty       -  No information is valid for the selected slot. This status is 
				                      relevant to a case in which the card configaration was deleted,
				                      or in case in which a slot was empty since the device startup."
              ::= { atmNteIdEntry 5 }

         atmNteCardCmd OBJECT-TYPE
              SYNTAX  INTEGER {
                notApplicable   (1),
                deleteConfig    (2),
				deactivate      (3),
				activate        (4)
	          }
              MAX-ACCESS  read-write
              STATUS  current
              DESCRIPTION
                      "Command on the card that is installed in the selected slot.
					  The commands are applicable according to the value of atmNteCardStatus.
					  See the specification document for details.
                      
                      deleteConfig - Deletes the card configuration. 
                      deactivate   - All the connections state will be changed to NotReady. The card 
                                     configuration will be blocked.
                      activate     - Does the same as done upon card insertion: Initiates the relevant 
                                     parameters, activates the physical layer, ATM layer and logical 
                                     layer."
              ::= { atmNteIdEntry 6 }

atmNteProgCardType OBJECT-TYPE
		SYNTAX  INTEGER {
			-- values 1...1000 (if needed) should be used
			-- the same as in atmNteCardType
			main			(251),
			control			(252),
			fan				(253),
			empty			(255),

			atm155			(1001),
			eth				(1002)
		}
		MAX-ACCESS  read-write
		STATUS current 
		DESCRIPTION
			"The programmed card type."
            ::= { atmNteIdEntry 7 }


         atmSysPSunits OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The number of power supply units."
              ::= { atmNteSysInfo 2 }

          atmSysPSunitsInUse OBJECT-TYPE
              SYNTAX  INTEGER { ps1(2), ps2(3) }
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
              "The main power supply in this unit."
              ::= { atmNteSysInfo 3 }

          atmSysFanUnits OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The number of fan units."
              ::= { atmNteSysInfo 4 }

          atmSysNetPrts OBJECT-TYPE
              SYNTAX  Integer32 
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The number of network ports."
              ::= { atmNteSysInfo 5 }

          atmSysNetPrtInUse OBJECT-TYPE
              SYNTAX  INTEGER { 
                      trunk1(2),
			          trunk2(3)
			  }
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The network port in use."
              ::= { atmNteSysInfo 6 }

          atmNteBridgingMode OBJECT-TYPE
               SYNTAX  INTEGER {
                       accessOnly(1),
                       accessAndSwitching (2)
               }
 	           MAX-ACCESS  read-write
               STATUS  current
               DESCRIPTION
               "Bridging mode can be one of the following: 
	            ATM <> Ethernet - Bridging is between the Ethernet 
	            port and the ATM port (there is no bridging between VCs).
	            ATM <> Ethernet + ATM - Bridging is done both between 
	            the Ethernet port and the ATM port and also between VCs."
               ::= { atmNteSysInfo 7}

          atmSysStats OBJECT IDENTIFIER ::= { atmNteSysInfo 8 }

          atmSysCurrentCdc  OBJECT-TYPE
                SYNTAX  Gauge32
                MAX-ACCESS  read-only
                STATUS  current
                DESCRIPTION
                        "Seconds in which cells dropped was occured in
                        the current 15 minutes interval."
                ::= { atmSysStats 1 }

          atmSysIntervalTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF AtmSysIntervalEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "The system level Interval table."
              ::= { atmSysStats 2 }

          atmSysIntervalEntry OBJECT-TYPE
              SYNTAX  AtmSysIntervalEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "."
              INDEX   { atmSysIntervalNumber }
              ::= { atmSysIntervalTable 1 }

          AtmSysIntervalEntry ::=
              SEQUENCE {
                  atmSysIntervalNumber
					  Integer32,
                  atmSysIntervalCdc
                      Gauge32
              }

          atmSysIntervalNumber OBJECT-TYPE
              SYNTAX  Integer32 (1..96)
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "A number between 1 and 96, where 1 is the most
                      recently completed 15 minute interval and 96 is
                      the least recently completed 15 minutes interval
                      (assuming that all 96 intervals are valid)."
              ::= { atmSysIntervalEntry 1 }

          atmSysIntervalCdc  OBJECT-TYPE
                SYNTAX  Gauge32
                MAX-ACCESS  read-only
                STATUS  current
                DESCRIPTION
                        "Seconds in which cells dropped was occured in
                        15 minutes interval."
                ::= { atmSysIntervalEntry 2 }

          atmNteEventType OBJECT-TYPE
               SYNTAX  INTEGER {
					ps1NotActive	(3),
					ps1Active		(4),
					ps2NotActive	(5),
					ps2Active		(6),
					heatAlarmOff	(7),
					heatAlarmOn		(8),
					inputAlarm1Off	(9),
					inputAlarm1On	(10),
					inputAlarm2Off	(11),
					inputAlarm2On	(12),
					inputAlarm3Off	(13),
					inputAlarm3On	(14),
					inputAlarm4Off	(15),
					inputAlarm4On	(16),
					fan1Ok	        (17),
					fan1Fail	    (18),
					fan2Ok	        (19),
					fan2Fail	    (20),
                    invalidLogin    (21),
                    validLogin      (22),
					powerFailure 	(23),
					writeToFlashFailure (24)
               }
 	           MAX-ACCESS  read-only
               STATUS  current
               DESCRIPTION
               "This parameter identifies the event.
               On  - the problem exist.
               Off - the problem not exist.
               InvalidLogin - Invalid login on local console.
               CorrectLogin - Successful login operation."
               ::= { atmNteSysInfo 9 }

         atmNteIntervalMaxNumber OBJECT-TYPE
              SYNTAX  Integer32 (1..96)
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The MAX number of connections intervals supported by system.
					  This parameter value is a function of atmNteConnectionsMaxNumber 
					  parameter.
					  This parameter should affect the threshold values selected by user.
                      Applicable to ace2002."
              ::= { atmNteSysInfo 10 }

        atmNteAlarmType OBJECT-TYPE
              SYNTAX INTEGER 
              {
		          notApplicable(1),
		          ais(2),
                  rdi(3),
		          continuityLoss(4),
		          loopback(5)
              } 
              MAX-ACCESS read-only
              STATUS  current
              DESCRIPTION
                "This object specifies the type of the alarm."
              ::= { atmNteSysInfo 11 }

        atmNteLevel OBJECT-TYPE
              SYNTAX INTEGER 
              {
		          vp(2),
		          vc(3)
              } 
              MAX-ACCESS read-only
              STATUS  current
              DESCRIPTION
                "This object specifies the ATM level."
              ::= { atmNteSysInfo 12 }

        atmNteConnectionsNumber OBJECT-TYPE
              SYNTAX Integer32 
              MAX-ACCESS read-only
              STATUS  current
              DESCRIPTION
                "This object specifies a quantity of connections."
              ::= { atmNteSysInfo 13 }

        atmNteTotalLb OBJECT-TYPE
              SYNTAX Integer32 
              MAX-ACCESS read-only
              STATUS  current
              DESCRIPTION
                "This parameter counts the total number of end-points
                that were configured with Loopback (LB)."
              ::= { atmNteSysInfo 14 }

        atmNteTotalCc OBJECT-TYPE
              SYNTAX Integer32 
              MAX-ACCESS read-only
              STATUS  current
              DESCRIPTION
                "This parameter counts the total number of end-points
                that were configured with Continuity Check (CC)."
              ::= { atmNteSysInfo 15 }

        atmNteTotalPm OBJECT-TYPE
              SYNTAX Integer32 
              MAX-ACCESS read-only
              STATUS  current
              DESCRIPTION
                "This parameter counts the total number of end-points
                that were configured with PM."
              ::= { atmNteSysInfo 16 }


--atmNtePrt  OBJECT IDENTIFIER  ::=  {atmNte 2}

-- Changed
atmNteLoopback  OBJECT IDENTIFIER  ::=  {atmNtePrt 2}
-- The loopback test consists of inserting special OAM cells. This test is started and stopped
-- upon operator request (by using MIB item atmVpConfLoopbackAdminStatus).
-- There are two tables per VP and two tables per VC: the measurements of the current 15 minutes,
-- and the measurement of the last 96 periods of 15 minutes.
atmLoopbackVpTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF AtmLoopbackVpEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
      "This table contains parameters for an OAM VP loopback test."
       ::= {atmNteLoopback 1 }

atmLoopbackVpEntry OBJECT-TYPE
      SYNTAX AtmLoopbackVpEntry
      MAX-ACCESS not-accessible
      STATUS current
	  DESCRIPTION "An entry in table atmLoopbackVpTable."
	  INDEX {atmLoopbackVpIfIndex,atmLoopbackVpVpi}
      ::= {atmLoopbackVpTable 1}

AtmLoopbackVpEntry ::=
      SEQUENCE {
	atmLoopbackVpIfIndex               Integer32,
	atmLoopbackVpVpi                   Integer32,
	atmLoopbackVpOperStatus            INTEGER,
	atmLoopbackVpCDV 		           Integer32,
	atmLoopbackVpAverageDelay          Integer32,
	atmLoopbackVpMaxDelay              Integer32,
	atmLoopbackVpMinDelay              Integer32,
	atmLoopbackVpErrSessions	       Integer32 
	}

atmLoopbackVpIfIndex OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The interface index of the ATM layer."
      ::= {atmLoopbackVpEntry 1}

atmLoopbackVpVpi OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The VPI of the OAM VPL."
      ::= {atmLoopbackVpEntry 2}


atmLoopbackVpOperStatus OBJECT-TYPE
      SYNTAX INTEGER {
	noActive(1),
	inProgress(2),
              failed(3),
	endSuccessfully(4)
                     } 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "-noActive(1) means that the loopback test has not been activated for this VP.
        -inProgress(2) means that the test has been activated and there is currently no problem.
        -failed(3) means there was problem during the test or after having stopped it
        -endSuccessfully(4) means that the test was stopped and all was OK."
      ::= {atmLoopbackVpEntry 3}

atmLoopbackVpCDV OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "Cell Delay Variation for this sampling."
      ::= {atmLoopbackVpEntry 4}

atmLoopbackVpAverageDelay OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      " Average delay without including lost cells."
      ::= {atmLoopbackVpEntry 5}

atmLoopbackVpMaxDelay OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "Maximum delay without including lost cells."
      ::= {atmLoopbackVpEntry 6}

atmLoopbackVpMinDelay OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "Minimum delay."
      ::= {atmLoopbackVpEntry 7}

atmLoopbackVpErrSessions OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "Errored Sessions. Will be updated once in 5 seconds."
      ::= {atmLoopbackVpEntry 8}

atmLoopbackVcTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF AtmLoopbackVcEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
      "This table contains parameters for an OAM VC loopback test."
       ::= {atmNteLoopback 2 }

atmLoopbackVcEntry OBJECT-TYPE
      SYNTAX AtmLoopbackVcEntry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION  "An entry in table."
      INDEX {atmLoopbackVcIfIndex,atmLoopbackVcVpi,atmLoopbackVcVci}
      ::= {atmLoopbackVcTable 1}

AtmLoopbackVcEntry ::=
      SEQUENCE {
	atmLoopbackVcIfIndex               Integer32,
	atmLoopbackVcVpi                   Integer32,
	atmLoopbackVcVci                   Integer32,
	atmLoopbackVcOperStatus            INTEGER,
	atmLoopbackVcCDV	               Integer32,
	atmLoopbackVcAverageDelay          Integer32,
	atmLoopbackVcMaxDelay              Integer32,
	atmLoopbackVcMinDelay              Integer32,
	atmLoopbackVcErrSessions           Integer32 
	}

atmLoopbackVcIfIndex OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The interface index of the ATM layer."
      ::= {atmLoopbackVcEntry 1}

atmLoopbackVcVpi OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The VPI of the OAM VCL."
      ::= {atmLoopbackVcEntry 2}

atmLoopbackVcVci OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The VCI of the OAM VCL."
      ::= {atmLoopbackVcEntry 3}


atmLoopbackVcOperStatus OBJECT-TYPE
      SYNTAX INTEGER {
	noActive(1),
	inProgress(2),
               failed(3),
	endSuccessfully(4)
                     } 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "-noActive(1) means that the loopback test has not been activated for this VP.
        -inProgress(2) means that the test has been activated and there is currently no problem.
        -failed(3) means there was problem during the test or after having stopped it
        -endSuccessfully(4) means that the test was stopped and all was OK."
      ::= {atmLoopbackVcEntry 4}

atmLoopbackVcCDV OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "Cell Delay Variation for this sampling."
      ::= {atmLoopbackVcEntry 5}


atmLoopbackVcAverageDelay OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      " Average delay without including lost cells."
      ::= {atmLoopbackVcEntry 6}

atmLoopbackVcMaxDelay OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The maximum delay without including lost cells."
      ::= {atmLoopbackVcEntry 7}

atmLoopbackVcMinDelay OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The minimum delay."
      ::= {atmLoopbackVcEntry 8}

atmLoopbackVcErrSessions OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "Errored Sessions. Will be updated once in 5 seconds."
      ::= {atmLoopbackVcEntry 9}


-- Entirely New
atmLoopbackVpIvlTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF AtmLoopbackVpIvlEntry 
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
      "This table contains parameters for an OAM VP loopback test,
	according interval number."
       ::= {atmNteLoopback 3 }

atmLoopbackVpIvlEntry OBJECT-TYPE
      SYNTAX AtmLoopbackVpIvlEntry 
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX { atmLoopbackVpIvlIfIndex, atmLoopbackVpIvlVpi, atmLoopbackVpIvlIvl }
      ::= { atmLoopbackVpIvlTable 1}

AtmLoopbackVpIvlEntry ::=
      SEQUENCE {
	atmLoopbackVpIvlIfIndex               Integer32,
	atmLoopbackVpIvlVpi                   Integer32,
	atmLoopbackVpIvlIvl 		          Integer32,
	atmLoopbackVpIvlOperStatus            INTEGER,
	atmLoopbackVpIvlCDV	                  Integer32,
	atmLoopbackVpIvlAverageDelay          Integer32,
	atmLoopbackVpIvlMaxDelay              Integer32,
	atmLoopbackVpIvlMinDelay              Integer32,
	atmLoopbackVpIvlErrSessions           Integer32 
	}
 
atmLoopbackVpIvlIfIndex OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The interface index of the ATM layer."
      ::= { atmLoopbackVpIvlEntry 1}

atmLoopbackVpIvlVpi OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The VPI of the OAM VPL."
      ::= { atmLoopbackVpIvlEntry 2}


atmLoopbackVpIvlIvl OBJECT-TYPE
      SYNTAX Integer32(1..96)
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The relevant interval number."
      ::= { atmLoopbackVpIvlEntry 3}

atmLoopbackVpIvlOperStatus OBJECT-TYPE
      SYNTAX INTEGER {
	noActive(1),
	inProgress(2),
               failed(3),
	endSuccessfully(4)
                     } 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "-noActive(1) means that the loopback test has not been activated for this VP during this interval.
        -inProgress(2) has no meaning for an ended interval.
        -failed(3) means there was problem during the test or after having stopped it
        -endSuccessfully(4) means that the test was OK."
      ::= { atmLoopbackVpIvlEntry 4}

atmLoopbackVpIvlCDV OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "Cell Delay Variation for this interval."
      ::= { atmLoopbackVpIvlEntry 5}


atmLoopbackVpIvlAverageDelay OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      " Average delay without including lost cells for this interval."
      ::= { atmLoopbackVpIvlEntry 6}

atmLoopbackVpIvlMaxDelay OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The maximum delay without including lost cells for this interval."
      ::= { atmLoopbackVpIvlEntry 7}

atmLoopbackVpIvlMinDelay OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The minimum delay for this interval."
      ::= {atmLoopbackVpIvlEntry 8}

atmLoopbackVpIvlErrSessions OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "Errored Sessions. Will be updated once in 5 seconds."
      ::= {atmLoopbackVpIvlEntry 9}


atmLoopbackVcIvlTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF AtmLoopbackVcIvlEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
      "This table contains parameters for an OAM VC loopback test."
       ::= {atmNteLoopback 4 }

atmLoopbackVcIvlEntry OBJECT-TYPE
      SYNTAX AtmLoopbackVcIvlEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {atmLoopbackVcIvlIfIndex, atmLoopbackVcIvlVpi, atmLoopbackVcIvlVci, atmLoopbackVcIvlIvl }
      ::= {atmLoopbackVcIvlTable 1}

AtmLoopbackVcIvlEntry ::=
      SEQUENCE {
	atmLoopbackVcIvlIfIndex               Integer32,
	atmLoopbackVcIvlVpi                   Integer32,
	atmLoopbackVcIvlVci                   Integer32,
	atmLoopbackVcIvlIvl 		          Integer32,
	atmLoopbackVcIvlOperStatus            INTEGER,
	atmLoopbackVcIvlCDV	                  Integer32,
	atmLoopbackVcIvlAverageDelay          Integer32,
	atmLoopbackVcIvlMaxDelay              Integer32,
	atmLoopbackVcIvlMinDelay              Integer32,
	atmLoopbackVcIvlErrSessions           Integer32 
	}

atmLoopbackVcIvlIfIndex OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The interface index of the ATM layer."
      ::= {atmLoopbackVcIvlEntry 1}

atmLoopbackVcIvlVpi OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The VPI of the OAM VCL."
      ::= {atmLoopbackVcIvlEntry 2}

atmLoopbackVcIvlVci OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The VCI of the OAM VCL."
      ::= {atmLoopbackVcIvlEntry 3}

atmLoopbackVcIvlIvl OBJECT-TYPE
      SYNTAX Integer32(1..96)
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The relevant interval number."
      ::= {atmLoopbackVcIvlEntry 4}

atmLoopbackVcIvlOperStatus OBJECT-TYPE
      SYNTAX INTEGER {
	noActive(1),
	inProgress(2),
               failed(3),
	endSuccessfully(4)
                     } 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "-noActive(1) means that the loopback test has not been activated for this VC during this interval.
        -inProgress(2) has no meaning per interval.
        -failed(3) means there was problem for this test during this interval.
        -endSuccessfully(4) means that the test was OK."
      ::= {atmLoopbackVcIvlEntry 5}

atmLoopbackVcIvlCDV OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "Cell Delay Variation for this interval."
      ::= {atmLoopbackVcIvlEntry 6}


atmLoopbackVcIvlAverageDelay OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      " Average delay without including lost cells."
      ::= {atmLoopbackVcIvlEntry 7}

atmLoopbackVcIvlMaxDelay OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The maximum delay without including lost cells."
      ::= {atmLoopbackVcIvlEntry 8}

atmLoopbackVcIvlMinDelay OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The minimum delay."
      ::= {atmLoopbackVcIvlEntry 9}

atmLoopbackVcIvlErrSessions OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "Errored Sessions. Will be updated once in 5 seconds."
      ::= {atmLoopbackVcIvlEntry 10}


atmNtePM  OBJECT IDENTIFIER  ::=  {atmNtePrt 3}

atmVpPmTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF AtmVpPmEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
      "This table contains parameters for VP performance monitoring."
       ::= {atmNtePM 1 }

atmVpPmEntry OBJECT-TYPE
      SYNTAX AtmVpPmEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {atmVpPmIfIndex,atmVpPmVpi}
      ::= {atmVpPmTable 1}

AtmVpPmEntry ::=
      SEQUENCE {
	atmVpPmIfIndex               Integer32,
	atmVpPmVpi                   Integer32,
	atmVpPmAdminStatus           INTEGER,
	atmVpPmDirection             INTEGER,
	atmVpPmBlockSize             Integer32,
	atmVpPmRowStatus             RowStatus,
	atmVpPmSink                  INTEGER,
	atmVpPmSource                INTEGER
      }

atmVpPmIfIndex OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The interface index of the ATM layer."
      ::= {atmVpPmEntry 1}

atmVpPmVpi OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The VPI of the Performance Monitoring VPL."
      ::= {atmVpPmEntry 2}

atmVpPmAdminStatus OBJECT-TYPE
      SYNTAX INTEGER {
             up  (2), 
             down(3),
             listenToActivationCells (4),
             originateActivationCells (5)     
      } 
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
      "up(2) - Activate PM.
       down(3) - Deactivate PM.
       listenToActivationCells(4) - . 
       originateActivationCells(5) - ."
      ::= {atmVpPmEntry 3}

atmVpPmDirection OBJECT-TYPE
      SYNTAX INTEGER  { 
             source(2), 
             destination(3), 
             bidirectional(4) 
      }
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
      "The direction of PM."
      ::= {atmVpPmEntry 4}

atmVpPmBlockSize OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
      "Valid block sizes (in cells): 128, 256, 512, 1024, 2048, 4096,
       8192, 16384, 32768."
      ::= {atmVpPmEntry 5}

atmVpPmRowStatus OBJECT-TYPE
      SYNTAX RowStatus 
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
      "Creation/Deletion of rows in the table."
      ::= {atmVpPmEntry 6}

atmVpPmSink OBJECT-TYPE
      SYNTAX INTEGER {
             off  (1), 
             fwd  (2),
             fwdAndBwdReport(3)     
      } 
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
      "off (1) - Deactivate PM.
       fwd (2) - Activate Forward PM only.
       fwdAndBwdReport(3) - Activate Forward PM and Backward reporting."
      ::= {atmVpPmEntry 7}

atmVpPmSource OBJECT-TYPE
      SYNTAX INTEGER {
             off  (1), 
             fwd  (2),
             fwdAndBwdReport(3)     
      } 
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
      "off (1) - Deactivate PM.
       fwd (2) - Activate Forward PM only.
       fwdAndBwdReport(3) - Activate Forward PM and Backward reporting."
      ::= {atmVpPmEntry 8}



atmVcPmTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF AtmVcPmEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
      "This table contains parameters for VC performance monitoring."
       ::= {atmNtePM 2 }

atmVcPmEntry OBJECT-TYPE
      SYNTAX AtmVcPmEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {atmVcPmIfIndex,atmVcPmVpi,atmVcPmVci}
      ::= {atmVcPmTable 1}

AtmVcPmEntry ::=
      SEQUENCE {
	atmVcPmIfIndex               Integer32,
	atmVcPmVpi                   Integer32,
	atmVcPmVci                   Integer32,
	atmVcPmAdminStatus           INTEGER,
	atmVcPmDirection             INTEGER,
	atmVcPmBlockSize             Integer32,
	atmVcPmRowStatus             RowStatus,
	atmVcPmSink                  INTEGER,
	atmVcPmSource                INTEGER
      }

atmVcPmIfIndex OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The interface index of the ATM layer."
      ::= {atmVcPmEntry 1}

atmVcPmVpi OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The VPI of the Performance Monitoring VCL."
      ::= {atmVcPmEntry 2}

atmVcPmVci OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The VCI of the PM VCL."
      ::= {atmVcPmEntry 3}

atmVcPmAdminStatus OBJECT-TYPE
      SYNTAX INTEGER {
             up  (2), 
             down(3),
             listenToActivationCells (4),
             originateActivationCells (5)     
      } 
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
      "up(2) - Activate PM.
       down(3) - Deactivate PM.
       listenToActivationCells(4) - . 
       originateActivationCells(5) - ."
      ::= {atmVcPmEntry 4}

atmVcPmDirection OBJECT-TYPE
      SYNTAX INTEGER  { source(2), destination(3), bidirectional(4)  }
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
      "The direction of PM."
      ::= {atmVcPmEntry 5}

atmVcPmBlockSize OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
      "Valid block sizes (in cells): 128, 256, 512, 1024, 2048, 4096,
       8192, 16384, 32768."
      ::= {atmVcPmEntry 6}

atmVcPmRowStatus OBJECT-TYPE
      SYNTAX RowStatus 
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
      "Creation/Deletion of rows in the table."
      ::= {atmVcPmEntry 7}

atmVcPmSink OBJECT-TYPE
      SYNTAX INTEGER {
             off  (1), 
             fwd  (2),
             fwdAndBwdReport(3)     
      } 
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
      "off (1) - Deactivate PM.
       fwd (2) - Activate Forward PM only.
       fwdAndBwdReport(3) - Activate Forward PM and Backward reporting."
      ::= {atmVcPmEntry 8}

atmVcPmSource OBJECT-TYPE
      SYNTAX INTEGER {
             off  (1), 
             fwd  (2),
             fwdAndBwdReport(3)     
      } 
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
      "off (1) - Deactivate PM.
       fwd (2) - Activate Forward PM only.
       fwdAndBwdReport(3) - Activate Forward PM and Backward reporting."
      ::= {atmVcPmEntry 9}

atmNteMdl  OBJECT IDENTIFIER  ::=  {atmNte 3}

atmNteMdlConfig  OBJECT IDENTIFIER  ::=  {atmNteMdl 1}

atmNteMdlConfigTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF AtmNteMdlConfigEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
      "Module configuration table."
       ::= { atmNteMdlConfig 1 }

atmNteMdlConfigEntry OBJECT-TYPE
      SYNTAX AtmNteMdlConfigEntry
      MAX-ACCESS not-accessible
      STATUS current
	  DESCRIPTION  
	  "There is an entry in this table just for those modules that have 
	  parameters that are relevant to module level only."
	  INDEX {atmNteMdlSlotIndex}
      ::= {atmNteMdlConfigTable 1}

AtmNteMdlConfigEntry ::=
      SEQUENCE {
	  atmNteMdlSlotIndex                Integer32,
	  atmNteMdlPrtCpuSharing            INTEGER,
	  atmNteMdlInputPriorityMechanism   INTEGER
	  }

atmNteMdlSlotIndex OBJECT-TYPE
      SYNTAX Integer32 (1..4)
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
      "The slot number."
      ::= { atmNteMdlConfigEntry 1}

atmNteMdlPrtCpuSharing OBJECT-TYPE
      SYNTAX INTEGER {
             equal      (2),
             port1      (3)     
      } 
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
      "This object lets the user decide what will be the CPU sharing 
       between the ports of the module. This object is applicable for 
       modules in which the same CPU handles the traffic of all ports.

       equal - All ports will have the same CPU resource.
       port1 - Port 1 will have higher priority than the other ports."
      ::= {atmNteMdlConfigEntry 2}

atmNteMdlInputPriorityMechanism OBJECT-TYPE
      SYNTAX INTEGER {
             disabled  (2),
             enabled   (3)     
      } 
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
      "This object allows the user to Enable/Disable the Input priority mechanism. 
      This object is applicable for modules	with more than one port, in which the 
      total ports input may be greater than the port output. 
      
      disabled - all LAN VCCs will be transmitted through the same queue (queue 1).
                Upon congestion frames will be dropped randomly.
      enabled -  the user should configure each port/connection priority. Upon 
                 congestion frames will be dropped according to priority."
      ::= {atmNteMdlConfigEntry 3}



atmGenSystem  OBJECT IDENTIFIER  ::=  {atmGen 2}

--atmGenModules  OBJECT IDENTIFIER  ::=  {atmGen 3}	 located in ace2002.txt


atmGenSysGen  OBJECT IDENTIFIER  ::=  {atmGenSystem 1}

-- The self test table

atmGenSysSelfTestTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF AtmGenSysSelfTestEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
      "A table containing the results of the initial testing of the device."
       ::= { atmGenSysGen 1 }

atmGenSysSelfTestEntry OBJECT-TYPE
      SYNTAX AtmGenSysSelfTestEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {atmGenSysSelfTestIndex}
      ::= {atmGenSysSelfTestTable 1}

AtmGenSysSelfTestEntry ::=
      SEQUENCE {
	  atmGenSysSelfTestIndex   Integer32,
	  atmGenSysSelfTestResult DisplayString
      }

atmGenSysSelfTestIndex OBJECT-TYPE
      SYNTAX Integer32
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "A running index for the table."
      ::= { atmGenSysSelfTestEntry 1}

atmGenSysSelfTestResult OBJECT-TYPE
      SYNTAX DisplayString
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The results of the initial testing of the device."
      ::= { atmGenSysSelfTestEntry 2}

-- The Log clear all

atmGenSysLogClearAll OBJECT-TYPE
      SYNTAX INTEGER { off(2),clear(3)}
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
      "Setting the variable to clear(3) removes all entries in the 
       Log Buffer of the agent. The agent will immediately
       reset the variable to off(2)."
      ::= { atmGenSysGen 2}

-- The Log table

atmGenSysLogTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF AtmGenSysLogEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
      "A copy of the log buffer."
       ::= { atmGenSysGen 3 }

atmGenSysLogEntry OBJECT-TYPE
      SYNTAX AtmGenSysLogEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {atmGenSysLogIndex}
      ::= {atmGenSysLogTable 1}

AtmGenSysLogEntry ::=
      SEQUENCE {
	  atmGenSysLogIndex   Integer32,
	  atmGenSysLogMessage DisplayString
      }

atmGenSysLogIndex OBJECT-TYPE
      SYNTAX Integer32 (1..2048)
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The index of the log buffer."
      ::= { atmGenSysLogEntry 1}

atmGenSysLogMessage OBJECT-TYPE
      SYNTAX DisplayString (SIZE(80))
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "The log buffer entry message text."
      ::= { atmGenSysLogEntry 2}

-- Set to default configuration

atmGenSysSetDefaultConfg OBJECT-TYPE
      SYNTAX INTEGER { off(2), on(3) }
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
      "When set to on(3), the agent will set all the configuration parameters
       to their default values. The variable is then reset to  off(2)
       by the agent. The agent must be reset for the default configuration
       to apply."
      ::=  {atmGenSysGen 4}

	-- A Cross Reference table for connections between tables. 
         
 atmGenSysCxRefTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF AtmGenSysCxRefEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                   "A Cross Reference table. The table maintains 
                    an index of an object which is also the table index, 
                    and a counter that indicates how many times this 
                    object was referenced.
                    When using this table for more than one referenced table,
					which uses the same range of indexes, then the index 
					should be shifted by a unique offset per table.
                       
                    In ACE2002 this table is used for TD and for FR Desc. Thus,
                    the index for FR Descriptor is: FR Descriptor index + offset. 
                    The offset is described in the ACE2002 NMS SRS."
              ::= {atmGenSysGen 5}

 atmGenSysCxRefEntry OBJECT-TYPE
              SYNTAX AtmGenSysCxRefEntry
              MAX-ACCESS  not-accessible
              STATUS  current
              DESCRIPTION
                      "The entries will be added by the agent upon
                       an entry addition in the referenced tables 
                       (TD table, FR Descriptor etc.)"
              INDEX   { atmGenSysCxRefIndex }
              ::= { atmGenSysCxRefTable 1 }

 	AtmGenSysCxRefEntry ::=
              SEQUENCE {
		 		atmGenSysCxRefIndex
                      	Integer32,
                atmGenSysCxRefCounter
                      	Gauge32
                }

 	atmGenSysCxRefIndex OBJECT-TYPE
              SYNTAX  Integer32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The index specifies an entry in the table of the object."
              ::= { atmGenSysCxRefEntry 1 }

 	atmGenSysCxRefCounter OBJECT-TYPE
              SYNTAX Gauge32
              MAX-ACCESS  read-only
              STATUS  current
              DESCRIPTION
                      "The counter counts the number of references 
						that have been made to the object ."
              ::= { atmGenSysCxRefEntry 2 }



-- Traps

-- System Layer Traps

atmAceStatusChange NOTIFICATION-TYPE
      OBJECTS  {agnLed,agnIndication}
      STATUS  current
      DESCRIPTION
       "The trap is sent every time there is a change in
	    the state of one of the LEDs."
      ::= { atmNteEvents 1 }

atmAceAlarmTrap NOTIFICATION-TYPE
      OBJECTS  {atmInterfaceAlarmStatus}
      STATUS  current
      DESCRIPTION
	  "The trap is sent whenever there is a transition from a no alarm
	   state to a state with at least one active alarm. An active alarm 
	   state exists if:
	   1) The atmInterfaceActiveAlarms vector is different than 0.
	   2) The atmNteAlarmVpTable contains entries.
	   3) The atmNteAlarmVcTable contains entries. 
	   The trap is also sent when a transition into the no alarm state
	   occurs.
                 The second variable will be atmInterfaceActiveAlarms to 
                 indicate the kind of the alarm.
                 The trap is not sent more than once in a 10 second interval."
      ::= { atmNteEvents 2 }

atmAceModuleChangeTrap NOTIFICATION-TYPE
      OBJECTS  {ifIndex}
      STATUS  current
      DESCRIPTION
	  "The trap is sent every time a module is changed (Hot swapping).
                  The second variable will be atmNteCardType to indicate the 
                  type of card that was inserted. The value empty(255) indicates that 
                  a card was taken out."
      ::= { atmNteEvents 3 }

atmAceRedundancyTrap NOTIFICATION-TYPE
      OBJECTS  {ifIndex }
      STATUS  current
      DESCRIPTION
	  	"The trap is sent upon change in link as a result of redundancy. 
                  The ifIndex parameter indicates the current active link."
      ::= { atmNteEvents 4 }

atmAceModuleMismatchTrap NOTIFICATION-TYPE
      STATUS  current
      DESCRIPTION
	  "The trap is sent upon starting or stopping of
	   a module mismatch state.
	   A possible mismatch is when the inserted module is other
	   than the programmed one."
      ::= { atmNteEvents 5 }


atmAceSystemTrap NOTIFICATION-TYPE
      OBJECTS  { atmNteEventType, agnLed, alarmSeverity }  
      STATUS  current
      DESCRIPTION
	  	"This trap alerts of major problems in the device."
      ::= { radSysAtmEvents  6 }

atmAceAlarmForwardingTrap NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState }  
      STATUS  current
      DESCRIPTION
	  	"This trap is sent upon starting or stopping Alarm 
	  	Forwarding Mechanism."
      ::= { radSysAtmEvents  7 }

atmAceDateAndTimeRequest NOTIFICATION-TYPE
--     OBJECTS  { sysObjectID }  
      STATUS  current
      DESCRIPTION
	  	"This trap is sent upon restart. It will send sysObjectID variable.
	  	Upon recieving this trap the NMS will set the device's date and time.
	  	This trap's purpose is to fix a problem in ACE2002, ACE-2002E, ACE-202.
	  	The problem is that the Date and Time is stored in the NVRAM, 
	  	and when the NVRAM's battery is empty, the device loses this information."
      ::= { radSysAtmEvents  8 }

-- Alarms Traps 
atmAceAlarmLOS NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates Loss Of Signal."
      ::= { radSysAtmEvents  16 }

atmAceAlarmLOF NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates Loss Of Frame."
      ::= { radSysAtmEvents  17 }

atmAceAlarmLCD NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates Loss of Cell Delineation."
      ::= { radSysAtmEvents  18 }

atmAceAlarmSLM NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates Signal Line Mismatch."
      ::= { radSysAtmEvents  19 }

atmAceAlarmLOP NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates Loss of Pointer."
      ::= { radSysAtmEvents  20 }

atmAceAlarmLineAIS NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates Line AIS."
      ::= { radSysAtmEvents  21 }

atmAceAlarmPathAIS NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates Path AIS."
      ::= { radSysAtmEvents  22 }

atmAceAlarmLineRDI NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates Line RDI."
      ::= { radSysAtmEvents  23 }

atmAceAlarmPathRDI NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates Path RDIand Path RAI(Yellow) for
	  	 DS1 interfaces."
      ::= { radSysAtmEvents  24 }

atmAceAlarmSectionBIP NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates Section Bit Interleave Parity."
      ::= { radSysAtmEvents  25 }

atmAceAlarmLineBIP NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates Line Bit Interleave Parity."
      ::= { radSysAtmEvents  26 }

atmAceAlarmPathBIP NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates Path Bit Interleave Parity."
      ::= { radSysAtmEvents  27 }

atmAceAlarmLineFEBE NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates Line Far End Block Error."
      ::= { radSysAtmEvents  28 }

atmAceAlarmPathFEBE NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates Path Far End Block Error."
      ::= { radSysAtmEvents  29 }

atmAceAlarmPlcpLOF NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates T3 PLCP Loss Of Frame."
      ::= { radSysAtmEvents  30 }


atmAceAlarmPlcpYELLOW NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates T3 Plcp Yellow."
      ::= { radSysAtmEvents  31 }

atmAceAlarmPlcpBIP NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates T3 Plcp Bit Interleave Parity."
      ::= { radSysAtmEvents  32 }

atmAceAlarmPlcpFEBE NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates T3 Plcp Far End Block Error."
      ::= { radSysAtmEvents  33 }

atmAceAlarmPlcpP1P2 NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates T3 Plcp Parity errors in P1/P2 bytes."
      ::= { radSysAtmEvents  34 }

atmAceAlarmUAS NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap is sent upon UAS start or end per port."
      ::= { radSysAtmEvents  35 }

atmAceAlarmCluster NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, atmNteAlarmType, atmNteLevel }  
      STATUS  current
      DESCRIPTION
	  	"This trap is sent upon atmNteAlarmType start or end,
	  	for a cluster of VPs/VCs (according to atmNteLevel) with 
	  	the same alarm on the same physical port.
	  	
	  	This trap replaces sending the same alarm for a big 
	  	quantity (the quantity described in the product 
	  	specification document) of VPs/VCs in order to prevent 
	  	flooding the NMS and the network with traps."
      ::= { radSysAtmEvents  36 }

atmAceHwFailure NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap is sent upon HW failure per port."
      ::= { radSysAtmEvents  37 }

atmAceUnavailableBwTrap NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, ifAlias, atmConfIfInputRate, atmConfIfOutputRate }  
      STATUS  current
      DESCRIPTION
	  	"This trap is sent when Bandwidth allocation is > max possible
	  	value for the installed card.
	  	
	  	For ACE2002 this trap will be sent for the following cases:
	  	
	  	Card insertion - if the total Input and/or Output Bandwidth is over 
	  	allocated, then the specific card rate will be set to 0 and this trap 
	  	will be sent with the Input/Output rates values. 
	  	
	  	Upgrade from former version - when an over allocated Bandwidth is detected, 
	  	this trap will be sent with atmConfIfInputRate=atmConfIfOutputRate=0xFFFFFFFF."
      ::= { radSysAtmEvents  38 }


--   
--   OAM LOOPBACK 
--   atmAceOAMLoopBackCellRx NOTIFICATION-TYPE
--         OBJECTS  { alarmSeverity, alarmState,ifAlias }  
--         STATUS  current
--         DESCRIPTION
--         "This Trap indicates that a loopback has 
--          been activated on device ATM uplink interface
--          by the remote ATM equipment, by means of OAM cells"
--         ::= { radSysAtmEvents  39 }
--   
--   
--   OAM LOOPBACK 
--   atmAceOAMLoopBackCellTx NOTIFICATION-TYPE
--         OBJECTS  { alarmSeverity, alarmState,ifAlias }  
--         STATUS  current
--         DESCRIPTION
--         "This Trap indicates that a loopback has 
--          been initiated by local device on ATM uplink interface
--          towards remote ATM equipment, by sending OAM cells."
--         ::= { radSysAtmEvents  15 }


-- VP Layer Traps

-- atmVplVpi have MAX-ACCESS "not-accessible"
-- and cannot be referenced from NOTIFICATION-TYPE clause
-- in SMIV2 so they where removed from following caluses.
-- Dovi Korngut (28/6/00).

atmAceAlarmVpContinuityLoss NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates Loss of Continuity Check on a VP Connection."
      ::= { radSysAtmEvents  40 }


atmAceAlarmVpAISReception NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates AIS Reception on a VP Connection."
      ::= { radSysAtmEvents  41 }


atmAceAlarmVpRDIReception NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates RDI Reception on a VP Connection."
      ::= { radSysAtmEvents  42 }


atmAceAlarmVpErroredCells NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates Errored Cells on a VP Connection reported by PM."
      ::= { radSysAtmEvents  43 }


atmAceAlarmVpLostCells NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates Lost Cells on a VP Connection reported by PM."
      ::= { radSysAtmEvents  44 }


atmAceAlarmVpMisinsertedCells NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates Misinserted Cells on a VP Connection 
	  	reported by PM."
      ::= { radSysAtmEvents  45 }

atmAceAlarmVpUAS NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap is sent upon UAS start or end per VP."
      ::= { radSysAtmEvents  46 }

atmAceAlarmVpLoopback NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap is sent upon OAM LoopBack fail status per VP."
      ::= { radSysAtmEvents  47 }

atmAceAlarmVpGCRAViolation NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }
      STATUS  current
      DESCRIPTION
	  	"This trap indicates GCRA violation on a VP Connection
		reported by UPC device."
      ::= { radSysAtmEvents  48 }


-- VC Layer Traps

-- atmVclVpi and atmVclVci have MAX-ACCESS "not-accessible"
-- and cannot be referenced from NOTIFICATION-TYPE clause
-- in SMIV2 so they where removed from following caluses.
-- Dovi Korngut (28/6/00).

atmAceAlarmVcContinuityLoss NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates  Loss of Continuity Check on a VC Connection."
      ::= { radSysAtmEvents  56 }

atmAceAlarmVcAISReception NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates AIS Reception on a VC."
      ::= { radSysAtmEvents  57 }

atmAceAlarmVcRDIReception NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates RDI Reception on a VC Connection."
      ::= { radSysAtmEvents  58 }

atmAceAlarmVcErroredCells NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates Errored Cells on a VC Connection reported by PM."
      ::= { radSysAtmEvents  59 }

atmAceAlarmVcLostCells NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates Lost Cells on a VC Connection reported by PM."
      ::= { radSysAtmEvents  60 }

atmAceAlarmVcMisinsertedCells NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates Misinserted Cells on a VC Connection reported 
	  	by PM."
      ::= { radSysAtmEvents  61 }

atmAceAlarmVcUnexpectedCell NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap indicates an unexpected cell from user or network port."
      ::= { radSysAtmEvents  62 }

atmAceAlarmVcUAS NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap is sent upon UAS start or end per VC."
      ::= { radSysAtmEvents  63 }

atmAceAlarmVcLoopback NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }  
      STATUS  current
      DESCRIPTION
	  	"This trap is sent upon OAM LoopBack fail status per VC."
      ::= { radSysAtmEvents  64 }

atmAceAlarmVcGCRAViolation NOTIFICATION-TYPE
      OBJECTS  { alarmSeverity, alarmState, ifAlias }
      STATUS  current
      DESCRIPTION
	  	"This trap indicates GCRA violation on a VC Connection
		reported by UPC device."
      ::= { radSysAtmEvents  65 }

-- number 80 and up are saved for IMA traps

-- END



-- SENDING OAM VC-AIS CELLS ??
--      This message appears when the LA-110 starts/stop
--      transmitting OAM cells of type VC-AIS to the 
--      ATM network the alarm description
--      will be followed with the relevant VP/VC
--

-- SENDING OAM VC-RDI CELLS  ???
--      This message appears when the LA-110 start/stop 
--      transmitting OAM cells of type VC-RDI to the 
--      ATM network the alarm description will be 
--      followed with the relevant VP/VC
-- 



-- 
-- file :v:\doc\rdv\mib\ver485\ipRouter.txt
-- 
	

--Version:   1.0
--Date:      31.01.99              
--By:        Ilana Schvetz
--File:      ipRouter.txt
--
--Last Update: Ilana Schvetz 09/01/02


--radRouter     OBJECT IDENTIFIER ::= { rad 11 }  
--rtrBridge     OBJECT IDENTIFIER ::= { radRouter 7 }

ipRouter OBJECT IDENTIFIER ::= { rtrBridge 3 }



rtrIfIpTable OBJECT-TYPE
       SYNTAX SEQUENCE OF RtrIfIpEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
          "Router interfaces table."
       ::= { ipRouter 1 }

rtrIfIpEntry OBJECT-TYPE
       SYNTAX  RtrIfIpEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
	   "An entry in table rtrIfIpTable."
       INDEX   { rtrIfIp }
       ::= { rtrIfIpTable 1 }

RtrIfIpEntry ::=
       SEQUENCE {
              rtrIfIp             IpAddress,
			  rtrIfRowStatus      RowStatus,
              rtrIfIpMask         IpAddress,
			  rtrIfIndex          Integer32,
			  rtrIfMng            INTEGER,
			  rtrIfVlanId		  VlanIndex
          }
   
rtrIfIp OBJECT-TYPE
       SYNTAX IpAddress
       MAX-ACCESS read-create
       STATUS current
       DESCRIPTION
           "IP Address."
       ::= { rtrIfIpEntry 1 }

rtrIfRowStatus OBJECT-TYPE
      SYNTAX  RowStatus
      MAX-ACCESS  read-create
      STATUS  current
      DESCRIPTION
          "."
      ::= { rtrIfIpEntry 2 }

rtrIfIpMask OBJECT-TYPE
       SYNTAX IpAddress
       MAX-ACCESS read-create
       STATUS current
       DESCRIPTION
           "IP mask Address."
       ::= { rtrIfIpEntry 3 }

rtrIfIndex OBJECT-TYPE
       SYNTAX Integer32
       MAX-ACCESS read-create
       STATUS current
       DESCRIPTION
           "The ifIndex connection, on which the IP is determined."
       ::= { rtrIfIpEntry 4 }

rtrIfMng OBJECT-TYPE
       SYNTAX INTEGER { 
           no  (1),
           yes (2)
       }
       MAX-ACCESS read-create
       STATUS current
       DESCRIPTION
           "An IP interface might be determined as a management 
           connection (under the product limitations)."
       ::= { rtrIfIpEntry 5 }

rtrIfVlanId OBJECT-TYPE
       SYNTAX      VlanIndex
       MAX-ACCESS  read-create
       STATUS      current
       DESCRIPTION
           "The VLAN ID assigned to Tagged frames transmitted 
            from this port.
            The value inserted should be a defined VLAN."
       ::= { rtrIfIpEntry 6 }


-- Brouter Table

brtrIfTable OBJECT-TYPE
       SYNTAX SEQUENCE OF BrtrIfEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
          "LAN interface table."
       ::= { ipRouter 2 }

brtrIfEntry OBJECT-TYPE
       SYNTAX  BrtrIfEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
           "The entries of this table will be created by agent."
       INDEX   { brtrIfIndex }
       ::= { brtrIfTable 1 }


BrtrIfEntry ::=
       SEQUENCE {
              brtrIfIndex         Integer32,
			  brtrIfMode          INTEGER,
			  brtrIfMaxFrameSize  Integer32
  	    }
   
brtrIfIndex OBJECT-TYPE
       SYNTAX Integer32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The index of the interface (LAN or ATM)."
       ::= { brtrIfEntry 1 }

brtrIfMode OBJECT-TYPE
       SYNTAX INTEGER { 
           bridge    (1),
           router    (2),
           brouter   (3),
		   off       (4)
       }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Connection Mode."
       ::= { brtrIfEntry 2 }

brtrIfMaxFrameSize OBJECT-TYPE
       SYNTAX Integer32
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Frame Max Size."
       ::= { brtrIfEntry 3 }



rtrArpAgingTime OBJECT-TYPE
       SYNTAX Integer32
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "ARP Aging Time. Applicable for a Router Mode 
           and for a Brouter Mode."
       ::= { ipRouter 3 }

-- Brouter LAN If table


brtrLanIfTable OBJECT-TYPE
       SYNTAX SEQUENCE OF BrtrLanIfEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
          "LAN interface table."
       ::= { ipRouter 4 }

brtrLanIfEntry OBJECT-TYPE
       SYNTAX  BrtrLanIfEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
           "The entries of this table will be created by agent ."
       INDEX   { brtrLanIfIndex }
       ::= { brtrLanIfTable 1 }


BrtrLanIfEntry ::=
       SEQUENCE {
              brtrLanIfIndex            Integer32,
			  brtrLanIpAddress          IpAddress,
			  brtrLanIpMask             IpAddress,
              brtrLanMaxRateEnable      INTEGER,
              brtrLanMaxRate            Integer32,
              brtrLanMng                INTEGER,
              brtrLanDefaultRouter      IpAddress
       }

brtrLanIfIndex OBJECT-TYPE
       SYNTAX Integer32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The index of the LAN entity (physical interface)."
       ::= { brtrLanIfEntry 1 }

brtrLanIpAddress OBJECT-TYPE
       SYNTAX IpAddress
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Host IP address. Applicable for bridge mode connection only."
       ::= { brtrLanIfEntry 2 }

brtrLanIpMask OBJECT-TYPE
       SYNTAX IpAddress
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Host IP Mask. Applicable for bridge mode connection only."
       ::= { brtrLanIfEntry 3 }


brtrLanMaxRateEnable OBJECT-TYPE
       SYNTAX INTEGER { 
          disable (1),
          enable  (2)
       }
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "This parameter determines the HW ability of the LAN 
           card according to HW."
       ::= { brtrLanIfEntry 4 }

brtrLanMaxRate OBJECT-TYPE
       SYNTAX Integer32
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Max Rate."
       ::= { brtrLanIfEntry 5 }

brtrLanMng OBJECT-TYPE
       SYNTAX INTEGER { 
           no  (1),
           yes (2)
       }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "An IP interface might be determined as a management 
           connection (under the product limitations)."
       ::= { brtrLanIfEntry 6 }

brtrLanDefaultRouter OBJECT-TYPE
       SYNTAX IpAddress
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Default Router's (Gateway's) IP Address.
            For each LAN interface there may be a different Default Router."
       ::= { brtrLanIfEntry 7 }



rtrIsdnIfTable OBJECT-TYPE
       SYNTAX SEQUENCE OF RtrIsdnIfEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
          "This table contains ISDN parameters that do not appear in the standard MIBs."
       ::= { ipRouter 5 }
			  
rtrIsdnIfEntry OBJECT-TYPE
       SYNTAX  RtrIsdnIfEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
           "Entries for ISDN parameters that do not appear in the standard MIBs."
       AUGMENTS    { isdnSignalingEntry }
--        INDEX { isdnSignalingIndex }
       ::= { rtrIsdnIfTable 1 }


RtrIsdnIfEntry ::=
       SEQUENCE {
              rtrIsdnIfMinNumBchans            Integer32,
              rtrIsdnIfMaxNumBchans            Integer32
       }

rtrIsdnIfMinNumBchans OBJECT-TYPE
       SYNTAX Integer32
       MAX-ACCESS read-create
       STATUS current
       DESCRIPTION
           "Minimum number of B channels that the ISDN Dialer of the router will use
            for Dialing out.
            This parameter will be used for the BOD (Bandwidth On Demand) feature.
            Dial up on B channels is according to the need of bandwidth for router 
            data transfer. Voice calls have a higher priority than router data.
            In case of few time slots the voice calls will cause disconnection of
            data channels up to the limit of minimum number of B channels."
       ::= { rtrIsdnIfEntry 1 }

rtrIsdnIfMaxNumBchans OBJECT-TYPE
       SYNTAX Integer32
       MAX-ACCESS read-create
       STATUS current
       DESCRIPTION
           "Maximum number of B channels that the ISDN Dialer of the router will use
            for Dialing out.
            This parameter will be used for the BOD (Bandwidth On Demand) feature.
            Dial up on B channels is according to the need of bandwidth for router 
            data transfer. Voice calls have a higher priority than router data.
            No more than MAX B channels will be used by the ISDN dialer."                     
       ::= {rtrIsdnIfEntry  2 }


rtrLcrTable OBJECT-TYPE
       SYNTAX SEQUENCE OF RtrLcrEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
          "Least Cost Routing Table.
           The user will be able to set a prefix for an outgoing number
           that arrives with a predefined prefix in order to redirect
           the number for the LCR process to be achieved."
       ::= { ipRouter 6 }
			  
rtrLcrEntry OBJECT-TYPE
       SYNTAX  RtrLcrEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
           "Least Cost Routing Entry."
       INDEX   { ifIndex, rtrLcrOutIfIndex }
       ::= { rtrLcrTable 1 }


RtrLcrEntry ::=
       SEQUENCE {
              rtrLcrOutIfIndex      InterfaceIndex,
			  rtrLcrRowStatus       RowStatus,
              rtrLcrInPrefix        DisplayString,
			  rtrLcrOutPrefix       DisplayString
       }

rtrLcrOutIfIndex OBJECT-TYPE
       SYNTAX InterfaceIndex
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "The outgoing interface Number of the current route.
            The incoming interface number is the value of ifIndex."
       ::= { rtrLcrEntry 1 }

rtrLcrRowStatus OBJECT-TYPE
      SYNTAX  RowStatus
      MAX-ACCESS  read-create
      STATUS  current
      DESCRIPTION
          "Row Status for adding/destroying rows."
      ::= { rtrLcrEntry 2 }

rtrLcrInPrefix OBJECT-TYPE
       SYNTAX DisplayString
       MAX-ACCESS read-create
       STATUS current
       DESCRIPTION
           "This prefix is part of the called number existing in the incoming packet."                     
       ::= {rtrLcrEntry  3 }

rtrLcrOutPrefix OBJECT-TYPE
       SYNTAX DisplayString
       MAX-ACCESS read-create
       STATUS current
       DESCRIPTION
           "This prefix will be inserted into the outgoing packet."
       ::= {rtrLcrEntry  4 }




--radRouter     OBJECT IDENTIFIER ::= { rad 11 }  

multicastGen    OBJECT IDENTIFIER ::= { radRouter 8 } -- General Multicast Parameters

multicastMode  OBJECT-TYPE
      SYNTAX INTEGER {
      disable  (2),        
      wanToLan (3),      
      wanToLanIgmp (4),
	  lanToWan (5),
      bidirectional(6),
      transparent(7)
      }
	  MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
      "According to this mode the packets will be forwarded.
       If disable (2) is selected, there will be no multicast."
      ::= { multicastGen 1 }
-- 
-- file :v:\doc\rdv\mib\ver485\clksrc.txt
-- 
-- file  : clksrc.txt
--
-- available for ACE2002. This file is part of dxc.txt.
--Version:   1.0
--Date:      9.7.00
--By:        Ilana Schvetz
--File:      v:\doc\rdv\mib\ver485\clksrc.txt 
 
--Last Update: 25.11.01 by Ilana 
-- Copyright 1997 RAD Data Communications, Ltd.
-- All Rights Reserved.


dacsMux       OBJECT IDENTIFIER ::= {radWan 3}

systemDacsMux OBJECT IDENTIFIER ::= {dacsMux 1}

sysStatus     OBJECT IDENTIFIER ::= {systemDacsMux 3}
sysConfig     OBJECT IDENTIFIER ::= {systemDacsMux 6}


sysSClkSrc  OBJECT-TYPE
      SYNTAX  INTEGER
    {
        master  (1),
        fallback(2),
        internal(3),
        ml      (4) 
    }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
     "This entry indicates the source of the system clock."
      ::= { sysStatus 7 }


--System Configuration Parameters

sysCClkSrcTable  OBJECT-TYPE
      SYNTAX SEQUENCE OF SysCClkSrcEntry
      MAX-ACCESS not-accessible
      STATUS  current
      DESCRIPTION
      "All the entries of this table are identical (have the 
       same value) for all the configurations (1..255) except 
       the TmpCnfg.
       The write operation into the Table Objects is valid only
       for the TmpCnfg entry."
       ::= { sysConfig 1}

sysCClkSrcEntry OBJECT-TYPE
      SYNTAX SysCClkSrcEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {sysCClkCnfgIdx, sysCClkSrcIdx}
      ::= { sysCClkSrcTable 1}

SysCClkSrcEntry ::=
      SEQUENCE {
   sysCClkCnfgIdx      Integer32,
   sysCClkSrcIdx       INTEGER,
   sysCClkSrcMode      INTEGER,
   sysCClkSrcPrt       Integer32,
   sysCClkStationFreq  INTEGER,
   sysCClkRevertiveTimeout  Integer32 
	}

sysCClkCnfgIdx OBJECT-TYPE
      SYNTAX Integer32 (1..255)
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
      "This attribute indicates the Idx of the Cnfg(1..255) being 
       accessed ; Idx of 255 relates to the TmpCnfg."
      ::= { sysCClkSrcEntry 1}
-- In phase I of DXC and FCD, only the values 1 (Cnfg1) and 255 
-- (temp) are valid.

sysCClkSrcIdx OBJECT-TYPE
      SYNTAX  INTEGER 
       {
     master    (1),
     fallback  (2)
    }
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "An index in the table. There are only two entries in the 
       table. 
       master   - refers Master clock parameters 
       fallback - refers Fallback clock parameters"
      ::= { sysCClkSrcEntry 2}

sysCClkSrcMode OBJECT-TYPE
      SYNTAX  INTEGER
       {
     none            (1),
     internal        (2),
     rxClk           (3),
     station         (4),
     lbt             (5),
	 ntr             (6),
	 adaptive        (7),  
     notApplicable (255)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This entry indicates the source the nodal timing is 
       locked to.
       none     - is an invalid option for Master clock.
       internal - is an invalid option for Fallback clock .
       station  - is an invalid option for a stand-alone unit. 
       lbt      - loop-back timing
	   ntr      - A system locked reference clock
	   adaptive - clcok locking is achieved by altering the clock 
	              according to the data load
       notApplicable - for ML source of Kmux or ML Timing 
                       combinations when Master/Fallback clock are
                       not applicable."
      ::= { sysCClkSrcEntry 3}


sysCClkSrcPrt OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This entry is valid only when working in rxClk mode.
       
       For ACE2002 in case of invalid entry the return value 
       will be 0. 
       For other products in case of invalid entry the return 
       value will be 9999.

       The valid port number depends on the IO slot no.,  the 
       installed card type and the port type: outside, inside, 
       SP.
    * The SP ports will be numbered as follows:
     - SP port 1 :  1
     - SP port 2 :  2
	   For external ports the convention used will be (for DXC):
         - first two digits will be: (IO slot number+10)
         - last one/two digits will be the port number within the 
           card, in odd numbers:
           port1 = 1
           port2 = 3
           port3 = 5 
           etc...
           Example: port2 of IO slot 11 will be: 213 .
       For internal ports the convention used will be (for DXC):
         - first two digits will be: (IO slot number+10)
         - last one/two digits will be the port number within the 
           card, in even numbers:
           port1 = 2
           port2 = 4
           port3 = 6 
           etc...
           Example: port2 of IO slot 11 will be: 214 .

      For Kmux, the port will be according to : Slot*100+Ch.
      
      For ACE2002 and LA140, the port will be ifIndex."
      ::= { sysCClkSrcEntry 4}


sysCClkStationFreq OBJECT-TYPE
      SYNTAX  INTEGER
       {
     notApplicable   (1),
     f1544Khz        (2),
     f2048Khz        (3)
       }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This entry indicates the frequency of the station clock 
       when the source is 'station'.  
       The value will be applicable only when the sysCClkSrcMode is 
       'station'. "
      ::= { sysCClkSrcEntry 5}

sysCClkRevertiveTimeout OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "The time in seconds in which the system will monitor the higher
       level clock source, before decision to revert to that clock.
       In case the time is zero, revertive mode will be disabled."
      ::= { sysCClkSrcEntry 6}

-- 
-- file :v:\doc\rdv\mib\ver495\sub_rtr.txt
-- 
-- version 4.95
-- file :sub_rtr.txt
-- 
--RTR-MIB  
--
--Last update: 30-Apr-2003 by Shay Harari
 

--radRouter         OBJECT IDENTIFIER ::= { rad 11 }  RAD Router

-- ************************************************
-- Interfaces Group
-- Link Layer (layer 2) Configuration MIB
-- ************************************************

-- The following MIB group is used by the Management/Configuration
-- station to configure the device interfaces,
-- physicals as well as virtuals.
-- Each entry in the rtrDynamicIfConfigTable should have one of 
-- the extended rtType.
-- It will also have a corresponding entry in the standard iftable.
-- The implementation uses these inputs to build the interface 
-- layer of the device. The output is reflected in the
-- ifTable and ifStackTable which are implementation dependent.
 

rtrInterfaces  OBJECT IDENTIFIER  ::= { radRouter 1 }

RtrIfConfigTYPE ::= INTEGER
--      STATUS  current
--       DESCRIPTION
--           "This type defines what type of sub-layer is used 
--            in each entr of rtrDynamicIfConfigTable.
--            It should contain values from IANAifType
--            type for standard sub-layer, and values (starting from 999 
--            decimal) for private sub-layers.
--            The values of the ifType field in ifTable should be taken 
--            from IANAifType only."
           {
            other(1),
            ethernetLan(6),          -- From IANAifType
            iso88023Csmacd(7),
            tokenRingLan(9),
            fddi(15),
            basicISDN(20),
            primaryISDN(21),
            propPointToPoint(22),    -- rndWAN
            slip(28),
            ppp(23),                 -- From IANAifType
            frameRelay(32),   
            rs232(33),       
            atm(37),
            x25ple(40),
            v35(45),
			fastEther(62),           -- Fast Ethernet (100BaseT)
			fastEtherFX(69),		 -- Fast Ethernet (100BaseFX)
            virtualNet(500),

            cod(1001),               -- Rad/Rnd private
            backUp(1002),            
            dialUp(1004),
            b1isdn(1010),
            b2isdn(1011),
            ipBcst(1020),
            ipPtp(1021),
            ipxRaw(1022),
            ipxEtType(1023),
            ipxLlcSap(1024),
            ipxLlcSnap(1025),
            ipxPtp(1026),
            brgUnder(1027),
            wanDriver(1060),
            ethernetDriver(1061),
            tokenRingDriver(1062),
			fddiDriver     (1064),   -- RAD private FDDI driver
            virtualLan(1080),
            unknown(1100)
          
           }

rtrConfigIfTable  OBJECT-TYPE     
       SYNTAX  SEQUENCE OF RtrConfigIfEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
           "Table of configured interfaces." 
      ::= { rtrInterfaces 1 }

rtrConfigIfEntry  OBJECT-TYPE     
       SYNTAX  RtrConfigIfEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
           "Each entry defines a configured interface." 
       INDEX { rtrConfigIfIndex }
      ::= { rtrConfigIfTable 1 }


RtrConfigIfEntry ::= SEQUENCE {
       rtrConfigIfIndex
           InterfaceIndex,
       rtrConfigIfType
           RtrIfConfigTYPE,
       rtrConfigIfName
           DisplayString,
       rtrConfigIfStatus
           RowStatus
       }

rtrConfigIfIndex   OBJECT-TYPE
       SYNTAX  InterfaceIndex
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
           "This variable uniquely identifies the interface. 
            It is used as a cross reference in other system tables"
      ::= { rtrConfigIfEntry 1 }

rtrConfigIfType   OBJECT-TYPE
       SYNTAX  RtrIfConfigTYPE
       MAX-ACCESS  read-create
       STATUS  current
       DESCRIPTION
           "This variable identifies the type of the specific 
            entry in the rtrDynamicIfConfigTable.
            This field is writable only at creation time 
            (i.e., when value of status is underCreation)."
       ::= { rtrConfigIfEntry 2 }

rtrConfigIfName   OBJECT-TYPE
       SYNTAX  DisplayString
       MAX-ACCESS  read-create
       STATUS  current
       DESCRIPTION
           "This variable provides a logical name to a specific entry in     
             rtrConfigIfTable. It is also used in identifying the Driver
             interfaces."
      ::= { rtrConfigIfEntry 3 }

rtrConfigIfStatus  OBJECT-TYPE
       SYNTAX  RowStatus
       MAX-ACCESS  read-create
       STATUS  current
       DESCRIPTION
          "The status of the ConfigEntry.  The choices are those 
           defined in SNMPv2-TC. Only: active, createAndWait, and destroy
           will be used.
           active - The conceptual row is available for use by the managed device.
           createAndWait - A new instance of a conceptual row is desired, but
                           not to have it available for use by the managed device.
           destroy - Delete all instances associated with an existing conceptual row."     
       ::= { rtrConfigIfEntry 4 }


-- Router Interface Configuration Table
 
rtrIfCfgTable  OBJECT-TYPE     
       SYNTAX  SEQUENCE OF RtrIfCfgEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
           "Router Interface Configuration Table." 
      ::= { rtrInterfaces 2 }

rtrIfCfgEntry  OBJECT-TYPE     
       SYNTAX  RtrIfCfgEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
           "An entry in the Router Interface Configuration Table." 
       INDEX { rtrIfCfgIndex, rtrIfCfgIpAddress }
      ::= { rtrIfCfgTable 1 }


RtrIfCfgEntry ::= SEQUENCE {
       rtrIfCfgIndex
           Integer32,
       rtrIfCfgIpAddress
           IpAddress,
       rtrIfCfgRowStatus
           RowStatus,
	   rtrIfCfgIpMask
		   IpAddress,
	   rtrIfCfgIfIndex
	       Integer32,
	   rtrIfCfgType
		   INTEGER,
	   rtrIfCfgVlanId
	       VlanIndex
       }

rtrIfCfgIndex OBJECT-TYPE
       SYNTAX Integer32
       MAX-ACCESS read-create
       STATUS current
       DESCRIPTION
       "This object indicates the Router Interface Index.
        (In some cases it will be equal to the Router Interface ifIndex)."
       ::= { rtrIfCfgEntry 1 }

rtrIfCfgIpAddress OBJECT-TYPE
       SYNTAX IpAddress
       MAX-ACCESS read-create
       STATUS current
       DESCRIPTION
       "IP Address of the Router Interface."
       ::= { rtrIfCfgEntry 2 }

rtrIfCfgRowStatus OBJECT-TYPE
      SYNTAX  RowStatus
      MAX-ACCESS  read-create
      STATUS  current
      DESCRIPTION
      "This object enables the user to 
       create/delete entries of this table."
      ::= { rtrIfCfgEntry 3 }

rtrIfCfgIpMask OBJECT-TYPE
       SYNTAX IpAddress
       MAX-ACCESS read-create
       STATUS current
       DESCRIPTION
           "IP Mask Address Router Interface."
       ::= { rtrIfCfgEntry 4 }

rtrIfCfgIfIndex OBJECT-TYPE
       SYNTAX Integer32
       MAX-ACCESS read-create
       STATUS current
       DESCRIPTION
       "ifIndex of the device interface connected
        to this Router Interface."
       ::= { rtrIfCfgEntry 5 }

rtrIfCfgType OBJECT-TYPE
       SYNTAX INTEGER { 
           notApplicable(1),
           atm     (2),
           lis     (3),
		   ethernet(4)
       }
       MAX-ACCESS read-create
       STATUS current
       DESCRIPTION
       "The Router Interface Type.
       atm       - ATM router interface
       lis       - Logical IP Subnet router interface. 
       ethernet  - Ethernet router interface. "
       ::= { rtrIfCfgEntry 6 }

rtrIfCfgVlanId OBJECT-TYPE
       SYNTAX      VlanIndex
       MAX-ACCESS  read-create
       STATUS      current
       DESCRIPTION
       "The VLAN ID assigned to Tagged frames transmitted 
        from this Router Interface.
        The value inserted should be a defined VLAN."
       ::= { rtrIfCfgEntry 7 }



-- ****************  Interfaces Groups End  *******************
 

-- ****************  IP Groups  ******************

-- IP Group

-- ************************************************
--      IP Interface Configuration MIB
-- ************************************************


ipSpec                 OBJECT IDENTIFIER ::= { radRouter 2 }              

rtrIpAddrTable OBJECT-TYPE
    SYNTAX  SEQUENCE  OF RtrIpAddrEntry 
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "This table is parralel to MIB II IpAddrTable, and is used to
        add/delete entries to/from that table. In addition it contains
        private objects."
    ::=  { ipSpec 1 }

rtrIpAddrEntry   OBJECT-TYPE
    SYNTAX  RtrIpAddrEntry 
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
            "The addressing information for one of this
            entity's IP addresses."
    INDEX  {rtrIpAdEntAddr}
    ::=  { rtrIpAddrTable 1 }

RtrIpAddrEntry ::= SEQUENCE {
    rtrIpAdEntAddr                IpAddress,
    rtrIpAdEntIfIndex             Integer32,
    rtrIpAdEntNetMask             IpAddress,
    rtrIpAdEntForwardIpBroadcast  INTEGER,
    rtrIpAdEntBackupAddr          IpAddress,
    rtrIpAdEntStatus              RowStatus
    }

rtrIpAdEntAddr OBJECT-TYPE
    SYNTAX  IpAddress
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The IP address to which this entry's addressing
            information pertains."
    ::= { rtrIpAddrEntry 1 }

rtrIpAdEntIfIndex OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-create
    STATUS  current
    DESCRIPTION
            "The index value which uniquely identifies the
            interface to which this entry is applicable.  The
            interface identified by a particular value of this
            index is the same interface as identified by the
            same value of ifIndex."
    ::= { rtrIpAddrEntry 2 }

rtrIpAdEntNetMask OBJECT-TYPE
    SYNTAX  IpAddress
    MAX-ACCESS  read-create
    STATUS  current
    DESCRIPTION
            "The subnet mask associated with the IP address of
            this entry.  The value of the mask is an IP
            address with all the network bits set to 1 and all
            the hosts bits set to 0."
    ::= { rtrIpAddrEntry 3 }

rtrIpAdEntForwardIpBroadcast OBJECT-TYPE
    SYNTAX INTEGER {
       enable(1),
       disable(2)
       }
    MAX-ACCESS  read-create
    STATUS  current
    DESCRIPTION
        " This variable controls forwarding of IP (sub)net-directed 
          broadcasts destined for an attached sub(net). "
    DEFVAL  { enable }
    ::=   { rtrIpAddrEntry 4 }

rtrIpAdEntBackupAddr OBJECT-TYPE
    SYNTAX  IpAddress
    MAX-ACCESS  read-create
    STATUS  current
    DESCRIPTION
            " "
    ::= { rtrIpAddrEntry 5 }

rtrIpAdEntStatus OBJECT-TYPE
    SYNTAX RowStatus
    MAX-ACCESS  read-create
    STATUS  current
    DESCRIPTION
        " The Status variable is used to create and destroy a Ip Addresses."
    ::=   { rtrIpAddrEntry 6 }

icmpSpec               OBJECT IDENTIFIER ::= { ipSpec 2 }
  
rtrIcmpGenErrMsgEnable   OBJECT-TYPE
    SYNTAX INTEGER {
       enable(1),
       disable(2)
   }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
           "This variable controlls the ability to generate ICMP error messages"
    DEFVAL  { enable }
    ::= { icmpSpec 1 }

rtrIcmpRdTable OBJECT-TYPE
    SYNTAX  SEQUENCE  OF RtrIcmpRdEntry 
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "This table contains ICMP Router Discovery parameters
        configurated per IP interface."
    ::=  {icmpSpec 2}

rtrIcmpRdEntry   OBJECT-TYPE
    SYNTAX  RtrIcmpRdEntry 
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
           "The ICMP parameters configurated for IP interface."
    INDEX  {rtrIcmpRdIpAddr}
    ::=  {rtrIcmpRdTable 1}

RtrIcmpRdEntry ::= SEQUENCE {
    rtrIcmpRdIpAddr             IpAddress,
    rtrIcmpRdIpAdvertAddr       IpAddress,
    rtrIcmpRdMaxAdvertInterval  Integer32,
    rtrIcmpRdMinAdvertInterval  Integer32,
    rtrIcmpRdAdvertLifetime     Integer32,
    rtrIcmpRdAdvertise          INTEGER,
    rtrIcmpRdPreferenceLevel    Integer32,
    rtrIcmpRdEntStatus          Integer32
    }

rtrIcmpRdIpAddr OBJECT-TYPE
    SYNTAX  IpAddress
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The IP address to which this entry's information pertains."
    ::= {rtrIcmpRdEntry 1}

rtrIcmpRdIpAdvertAddr OBJECT-TYPE
    SYNTAX  IpAddress
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
            " The IP destination address to be used for multicast
              Router Advertisements sent from the interface. The
              only permissible values are the all-systems multicast
              address, 224.0.0.1, or the limited-broadcast address,
              255.255.255.255."
--    DEFVAL  {224.0.0.1}
    ::= {rtrIcmpRdEntry 2}

rtrIcmpRdMaxAdvertInterval OBJECT-TYPE
    SYNTAX  Integer32 (4..1800)
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
            "The maximum time allowed between sending multicast
             Router Advertisements from the interface, in seconds.
             Must be no less than 4 seconds and no greater than 1800
             seconds."
    DEFVAL  {600}
    ::= {rtrIcmpRdEntry 3}

rtrIcmpRdMinAdvertInterval OBJECT-TYPE
    SYNTAX  Integer32 (3..1800)
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
            "The minimum time allowed between sending unsolicited
             multicast Router Advertisements from the interface, in
             seconds.  Must be no less than 3 seconds and no greater
             than rtrIcmpRdMaxAdvertInterval.
             Default: 0.75 * rtrIcmpRdMaxAdvertInterval."
    ::= {rtrIcmpRdEntry 4}

rtrIcmpRdAdvertLifetime OBJECT-TYPE
    SYNTAX  Integer32 (4..9000)
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
             "The maximum length of time that the advertised addresses
             are to be considered as valid. Must be no less than 
             rtrIcmpRdMaxAdvertInterval and no greater than 9000 seconds.
             Default: 3 * rtrIcmpRdMaxAdvertInterval."
    ::= {rtrIcmpRdEntry 5}

rtrIcmpRdAdvertise OBJECT-TYPE
    SYNTAX  INTEGER {
       enable  (1),
       disable (2)
       }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
             "A flag indicating whether or not the address is to be
              advertised."
    DEFVAL  {enable}
    ::= {rtrIcmpRdEntry 6}

rtrIcmpRdPreferenceLevel OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
             "The preferability of the address as a default router
             address, relative to other router addresses on the same
             subnet."
    DEFVAL  {0}
    ::= {rtrIcmpRdEntry 7}

rtrIcmpRdEntStatus  OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
            "Setting of any value to this object set values of
             all fields to the default values."
    ::=   {rtrIcmpRdEntry 8}


rip2Spec              OBJECT IDENTIFIER ::= { ipSpec  3 }

rtrRip2IfConfTable OBJECT-TYPE
    SYNTAX  SEQUENCE  OF RtrRip2IfConfEntry 
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
    "This table is an extension of rip2IfConfTable (RFC 1724 ,RIP 2).
     It means that every time somebody creates/destroys a row in the
     rip2IfConfTable, the same row should be automatically created/destroyed  
     in this table."
    ::=  { rip2Spec 1  }

rtrRip2IfConfEntry   OBJECT-TYPE
    SYNTAX  RtrRip2IfConfEntry 
    MAX-ACCESS  not-accessible
    STATUS  current
	DESCRIPTION
	"An entry in table rtrRip2IfConfTable."
    INDEX  { rtrRip2IfConfAddress }
    ::=  {  rtrRip2IfConfTable 1  }

RtrRip2IfConfEntry  ::= SEQUENCE { 
    rtrRip2IfConfAddress          IpAddress,
    rtrRip2IfConfVirtualDis       Integer32,
    rtrRip2IfConfAutoSend           INTEGER
    }

rtrRip2IfConfAddress  OBJECT-TYPE
    SYNTAX IpAddress
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
      " The IP Address of this system on the indicated subnet. "
    ::=  { rtrRip2IfConfEntry 1 }

rtrRip2IfConfVirtualDis OBJECT-TYPE
    SYNTAX Integer32 
    MAX-ACCESS  read-write 
    STATUS  deprecated
    DESCRIPTION
         "This variable defines the virtual number of hops assigned to 
          the interface specified by rtrIfIpAddrIndex. This enables 
          fine-tuning of the RIP routing algorithm."
    DEFVAL  { 1 }
    ::=   { rtrRip2IfConfEntry  2  }

rtrRip2IfConfAutoSend OBJECT-TYPE
    SYNTAX INTEGER  {
       enable(1),
       disable(2)
    }
    MAX-ACCESS  read-write
    STATUS  deprecated
    DESCRIPTION
         "When set to enable only the default route is sent through
          the interface. When set to disable, regular RIPs are sent."
    DEFVAL  { disable }
    ::=   { rtrRip2IfConfEntry  3  }


arpSpec                OBJECT IDENTIFIER ::= { ipSpec 4 }

rtrArpDeleteTable OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
         "Setting this object to any not-null value has the effect of deleting 
          all entries of the ARP table."
    ::= { arpSpec 1  }

rtrArpInactiveTimeOut OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
         "This variable defines the maximum time period (in second) that can
          pass between ARP requests concerning an entry in the ARP table.
          After this time period, the entry is deleted from the table."
    DEFVAL  { 60000 }
    ::= { arpSpec 2  }

rtrArpProxy OBJECT-TYPE
    SYNTAX INTEGER {
       enable(1),
       disable(2)
    }
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
         "When ARP Proxy is enabled, the router can respond to 
          ARP requests for nodes located on a different sub-net, 
          provided they are it its network table. The router responds 
          with its own MAC address. 
          When ARP Proxy is disabled, the router responds only
          to ARP requests for its own IP addresses."
    DEFVAL  { disable }
    ::= { arpSpec 3  }


-- ****************************************
--      NAT    Network Address Translation 
-- *****************************************

rtrNat     OBJECT IDENTIFIER ::= { ipSpec 5 }

rtrNatIfConfTable OBJECT-TYPE
       SYNTAX      SEQUENCE OF RtrNatIfConfEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
       "A list of interfaces which require separate NAT configuration."  
       ::= {rtrNat 1}

rtrNatIfConfEntry OBJECT-TYPE
       SYNTAX      RtrNatIfConfEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
       "A single routing domain in a single subnet."
       INDEX   { ifIndex, rtrNatIfVirtualAddress, rtrNatIfVirtualMask }
       ::= { rtrNatIfConfTable 1 }


RtrNatIfConfEntry ::=
      SEQUENCE {
        rtrNatIfVirtualAddress IpAddress,
        rtrNatIfVirtualMask    IpAddress,
        rtrNatIfConfStatus     RowStatus,
        rtrNatIfRealAddress    IpAddress,
        rtrNatIfRealMask	   IpAddress,
		rtrNatIfType           INTEGER
}


rtrNatIfVirtualAddress OBJECT-TYPE
   SYNTAX  IpAddress
   MAX-ACCESS  read-only
   STATUS  current
   DESCRIPTION
   "The IP Address of the virtual subnet to be translated by the 'NAT box' 
    attached to this interface."
   ::= { rtrNatIfConfEntry 1 }

rtrNatIfVirtualMask OBJECT-TYPE
   SYNTAX  IpAddress
   MAX-ACCESS  read-only
   STATUS  current
   DESCRIPTION
   "The subnet Mask of the virtual subnet. "
   ::= { rtrNatIfConfEntry 2 }

rtrNatIfConfStatus OBJECT-TYPE
   SYNTAX  RowStatus
   MAX-ACCESS read-create
   STATUS  current
   DESCRIPTION
   "Writing 'destroy' has the effect of deleting this interface."
   ::= { rtrNatIfConfEntry 3 }

rtrNatIfRealAddress OBJECT-TYPE
   SYNTAX  IpAddress
   MAX-ACCESS read-create
   STATUS  current
   DESCRIPTION
   " The IP Address of the real subnet which is used by 'NAT box' for translation."
   ::= { rtrNatIfConfEntry 4 }

rtrNatIfRealMask OBJECT-TYPE
   SYNTAX  IpAddress
   MAX-ACCESS read-create
   STATUS  current
   DESCRIPTION
   " The subnet Mask of the real subnet."
   ::= { rtrNatIfConfEntry 5 }

rtrNatIfType OBJECT-TYPE
   SYNTAX INTEGER { 
	              static      (1), 
				  dynamic     (2), 
	              pat         (3),
	              transparent (4) 
				   }
   MAX-ACCESS read-create
   STATUS  current
   DESCRIPTION
   "NAT type.
    
    static - Translate a specific virtual IP network to a specific real IP 
             network. TCP, UDP and ICMP sessions originated both in real and 
             virtual networks will be translated.
	dynamic - (Concurrent) Translate real IP network to larger or equal virtual 
	         IP network. TCP, UDP and ICMP sessions originated in virtual 
	         networks only	can be translated and sessions originated in real 
	         networks will be rejected. A session that starts in the NAT system 
	         will be active until there will be no traffic for aging timeout 
	         period.         
    pat    - (Port Address Translation/ Single IP).
             Translate one real IP address to virtual IP network. TCP, UDP and 
             ICMP sessions originated in virtual network only can be translated, 
             sessions originated in real network will be rejected. A session 
             that starts in the NAT system will be active until there will be no 
             traffic for aging timeout period.
    transparent - In transparent mode all frames belonging to the defined IP 
             network will be forwarded with no translation: virtual = real."     
   ::= { rtrNatIfConfEntry 6 }


-- *************************************
--           Port Address Translation
-- *************************************

rtrPatTable OBJECT-TYPE
       SYNTAX      SEQUENCE OF RtrPatEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
       "Port Address Translation (PAT -  single IP NAT) configuration Table."  
       ::= {rtrNat 2}

rtrPatEntry OBJECT-TYPE
       SYNTAX      RtrPatEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
       "Each entry describe unique mapping between real IP address, 
       range of ports and protocol, to local (virtual) IP address.
       Ports are used in the TCP (rfc793) to name the ends of logical
       connections which carry long term conversations.  
       For the purpose of providing services to unknown callers, 
       a service contact port is defined. "
       INDEX   { rtrPatIdx }
       ::= { rtrPatTable 1 }

RtrPatEntry ::=
      SEQUENCE {
        rtrPatIdx             Integer32,
        rtrPatRealAddress     IpAddress,
        rtrPatVirtualAddress  IpAddress,
        rtrPatLowestPort      Integer32,
        rtrPatHighestPort     Integer32,
		rtrPatProtocol		  INTEGER,
		rtrPatStatus		  RowStatus
               }								

rtrPatIdx OBJECT-TYPE
   SYNTAX  Integer32 (1..8)
   MAX-ACCESS  read-only
   STATUS  current
   DESCRIPTION
   "Running index for PAT table."
   ::= { rtrPatEntry 1 }
			  
rtrPatRealAddress OBJECT-TYPE
   SYNTAX      IpAddress
   MAX-ACCESS  read-create
   STATUS  current
   DESCRIPTION
   "The real IP Address used for translation "
   ::= { rtrPatEntry 2 }

rtrPatVirtualAddress OBJECT-TYPE
   SYNTAX      IpAddress
   MAX-ACCESS  read-create
   STATUS  current
   DESCRIPTION
   "The virtual IP Address used for translation"
   ::= { rtrPatEntry 3 }

rtrPatLowestPort OBJECT-TYPE
   SYNTAX      Integer32 (0..65535)
   MAX-ACCESS  read-create
   STATUS  current
   DESCRIPTION
   "Lowest Port number for this PAT entry "
   ::= { rtrPatEntry 4 }

rtrPatHighestPort OBJECT-TYPE
   SYNTAX      Integer32 (0..65535)
   MAX-ACCESS  read-create
   STATUS  current
   DESCRIPTION
   "Highest Port number for this PAT entry "
   ::= { rtrPatEntry 5 }

rtrPatProtocol OBJECT-TYPE
   SYNTAX  INTEGER
           {
           tcp (6),
	       udp (17)
	        }
   MAX-ACCESS read-create
   STATUS  current
   DESCRIPTION
   "Protocol selected.
    This Protocol and port range (lowest port - highest port)
    define the application (FTP, Telnet, SMTP etc.).
    Protocol enumaration numbers correspond to 
    IP header 'protocol' field "
   ::= { rtrPatEntry 6 }

rtrPatStatus OBJECT-TYPE
   SYNTAX  RowStatus
   MAX-ACCESS read-create
   STATUS  current
   DESCRIPTION
   "This object enables creating and deleting 
    entries of the table."
   ::= { rtrPatEntry 7 }



-- ************************************************
--                        FACS MIB
-- ************************************************


rtrFACS    OBJECT IDENTIFIER ::=  { radRouter 5 }

rtrFACSDefaultAction OBJECT-TYPE
   SYNTAX  INTEGER {
      block(1),
      forward(2),
      blockAndReport(129)
   }
   MAX-ACCESS  read-write  
   STATUS  current
   DESCRIPTION
         "Used to define the default action for the device, when no
          FACS statements applicable to a given frame are defined."
                
--  DEFVAL  { 1 }
  ::= { rtrFACS 1 }

rtrFACSActTable OBJECT-TYPE
   SYNTAX  SEQUENCE OF RtrFACSActEntry
   MAX-ACCESS  not-accessible
   STATUS  current
   DESCRIPTION
        "The table of  FACS action."
   ::= { rtrFACS 2 }

rtrFACSActEntry OBJECT-TYPE
   SYNTAX  RtrFACSActEntry
   MAX-ACCESS  not-accessible
   STATUS  current
   DESCRIPTION
        "Each rtrFACSActEntry consist of the following parameters"
   INDEX   {rtrFACSActType,
            rtrFACSActIfIndex}
   ::= { rtrFACSActTable 1 }

RtrFACSActEntry ::= SEQUENCE {
   rtrFACSActType    INTEGER,
   rtrFACSActIfIndex Integer32,
   rtrFACSAction     INTEGER,
   rtrFACSActiveDB   INTEGER
}

rtrFACSActType OBJECT-TYPE
   SYNTAX  INTEGER {
      tx(1),
      rx(2)
            }
   MAX-ACCESS  read-only
   STATUS  current
   DESCRIPTION
        "This parameter indicates on which FACS Table the FACS 
        action will preform."
   ::= { rtrFACSActEntry 1 }

rtrFACSActIfIndex OBJECT-TYPE
   SYNTAX  Integer32
   MAX-ACCESS  read-only
   STATUS  current
   DESCRIPTION
         "The interface to which this FACS entry is applicable."
   ::= { rtrFACSActEntry 2 }

rtrFACSAction OBJECT-TYPE
   SYNTAX  INTEGER {
       none(1),
       eraseIP(2),
       eraseDECnet(3),
       eraseIPX(4),
       eraseBrg(5),
       replaceIP(6),
       replaceIPX(8),
       replaceBrg(9),
       backupIP(10),
       backupIPX(12),
       backupBrg(13)
   }
   MAX-ACCESS  read-write
   STATUS  current
   DESCRIPTION
       "The management station that sends a SET request for one of these actions
       with indexes  rtrFACSType and rtrFACSIfIndex defines the type and the
       interface  Id for which all FACS statements are to be erased. 
       If no interface or no type  is specified, all FACS statements for a 
       protocol are erased."
-- DEFVAL  { 1 }
   ::= { rtrFACSActEntry 3 }

rtrFACSActiveDB OBJECT-TYPE
   SYNTAX INTEGER {
      active(1),
      temporary(2)
   }
   MAX-ACCESS  read-write
   STATUS  current
   DESCRIPTION
        "This parameter will point on which Facs DataBase the SNMP agent 
         read. The Active dataBase is Read Only. The user may change FACS 
         statements in the temporary DataBase and then write it to the 
         Active DB."
      ::= { rtrFACSActEntry 4}
     
rtrFACSTable OBJECT-TYPE
  SYNTAX  SEQUENCE OF RtrFACSEntry
  MAX-ACCESS  not-accessible
  STATUS  current
  DESCRIPTION
       "The table of  FACS statment."
  ::= { rtrFACS 3 }

rtrFACSEntry OBJECT-TYPE
  SYNTAX  RtrFACSEntry
  MAX-ACCESS  not-accessible
  STATUS  current
  DESCRIPTION
         "Each FACS statment consists of the following parameters"
  INDEX  {rtrFACSIfIndex,
          rtrFACSProtocolType,
          rtrFACSType,
          rtrFACSIndex } 
  ::= { rtrFACSTable 1 }

RtrFACSEntry ::= SEQUENCE {
   rtrFACSIfIndex      Integer32,
   rtrFACSProtocolType INTEGER,
   rtrFACSType         INTEGER,
   rtrFACSIndex        Integer32,
   rtrFACSSrcAdd       OCTET STRING ,
   rtrFACSSrcAddMask   OCTET STRING,
   rtrFACSDesAdd       OCTET STRING,
   rtrFACSDesAddMask   OCTET STRING,
   rtrFACSOperation    INTEGER,
   rtrFACSNetFiltering INTEGER,
   rtrFACSSocketNum     Integer32,
   rtrFACSMask1Id      Integer32,
   rtrFACSMask2Id      Integer32,
   rtrFACSStatus       INTEGER
  }

rtrFACSIfIndex OBJECT-TYPE
  SYNTAX  Integer32  
  MAX-ACCESS  read-only
  STATUS  current
  DESCRIPTION
         "The interface to which this FACS entry is applicable.
          For applications this variables is always 0."
  ::= { rtrFACSEntry 1 }

rtrFACSProtocolType OBJECT-TYPE
  SYNTAX  INTEGER{
     ip(1),
     ipx(2),
     dec(3),
     bridge(4)
  }
  MAX-ACCESS  read-only
  STATUS  current
  DESCRIPTION
       "This parameter define the protocol the Security  Access Control
       is applicable."
  ::= { rtrFACSEntry 2 }

rtrFACSType OBJECT-TYPE
  SYNTAX  INTEGER {
      tx(1),
      rx(2),
      cod(3)
  }
  MAX-ACCESS  read-only
  STATUS  current
  DESCRIPTION
       " The Mode of in which this FACS statement operates.
         For applications this variable is always rx(2)."
  ::= { rtrFACSEntry 3 }

rtrFACSIndex OBJECT-TYPE
  SYNTAX  Integer32
  MAX-ACCESS  read-only
  STATUS  current
  DESCRIPTION
       "Index to the FACS  Table. "
  ::= { rtrFACSEntry 4 }

rtrFACSSrcAdd OBJECT-TYPE
  SYNTAX  OCTET STRING 
  MAX-ACCESS  read-write
  STATUS  current
  DESCRIPTION
       "The size of the octet string will be according to the protocol type 
        defined in rtrFACSProtocolType."
  ::= { rtrFACSEntry 5 }

rtrFACSSrcAddMask OBJECT-TYPE
  SYNTAX   OCTET STRING 
  MAX-ACCESS  read-write
  STATUS  current
  DESCRIPTION
         "Source-address mask ."
  ::= { rtrFACSEntry 6 }

rtrFACSDesAdd OBJECT-TYPE
  SYNTAX   OCTET STRING
  MAX-ACCESS  read-write
  STATUS  current
  DESCRIPTION
      "Destination-address The size of the octet string will be according to the
      protocol type define in rtrFACSProtocolType ."
  ::= { rtrFACSEntry 7 }


rtrFACSDesAddMask OBJECT-TYPE
   SYNTAX   OCTET STRING
   MAX-ACCESS  read-write
   STATUS  current
   DESCRIPTION
       "Destination-address mask ."
   ::= { rtrFACSEntry 8 }


rtrFACSOperation OBJECT-TYPE
   SYNTAX  INTEGER {
       block(1),
       forward(2),
       permit(3),        -- For Connect On demand Only
       deny(4),          -- For Connect On demand Only
       blockAndReport(129)
   }
   MAX-ACCESS  read-write
   STATUS  current
   DESCRIPTION
               "... ."
   ::= { rtrFACSEntry 9 }

rtrFACSNetFiltering OBJECT-TYPE
   SYNTAX  INTEGER {
       none(1), 
       l2multicast(2), --applicable for Bridge protocol 
       arp(3),      --applicable for ip protocol 
       icmp(4),     --applicable for ip protocol 
       ip(5),       --applicable for ip protocol 
       udp(6),      --applicable for ip protocol 
       tcp(7),      --applicable for ip protocol 
       decnet(8),   --applicable for decnet protocol 
       ipx(9)      --applicable for ipx protocol 
   }
   MAX-ACCESS  read-write
   STATUS  current
   DESCRIPTION
      "... ."
   ::= { rtrFACSEntry 10 }


rtrFACSSocketNum OBJECT-TYPE   --applicable for ip,ipx protocol 
   SYNTAX  Integer32 
   MAX-ACCESS  read-write
   STATUS  current
   DESCRIPTION
       " Port/socket  number for different applications
       0 is default meaning not applicable.
       none(1),
       ftp(21),
       telnet(23),
       smtp(25),
       tftp(69),
       snmp(161),
       snmpTrap(162),
       rip(520),
       sapIPX(1106),
       ripIPX(1107)    "
   ::= { rtrFACSEntry 11}

rtrFACSMask1Id OBJECT-TYPE
   SYNTAX  Integer32
   MAX-ACCESS  read-write
   STATUS  current
   DESCRIPTION
       " Index into RND mask table FACS/COD Type) ."
   ::= { rtrFACSEntry 12}

rtrFACSMask2Id OBJECT-TYPE
   SYNTAX  Integer32
   MAX-ACCESS  read-write
   STATUS  current
   DESCRIPTION
       " Index into RND mask table FACS/COD according to
       the value of rtrFACSType ."
   ::= { rtrFACSEntry 13}

rtrFACSStatus OBJECT-TYPE
   SYNTAX  INTEGER {
      valid(1),
      createRequest(2),  
      underCreation(3), 
      invalid(4)          -- logically deleted
   }

   MAX-ACCESS  read-write
   STATUS  current
   DESCRIPTION
       "The status of a table entry."
   ::= { rtrFACSEntry 14}


rtrFACSFrameData OBJECT-TYPE
   SYNTAX  OCTET STRING (SIZE(0..256))
   MAX-ACCESS  read-only
   STATUS  current
   DESCRIPTION
         "Data from the frame that violated a FACS Filter."
  ::= { rtrFACS 4 }

-- ****************  FACS Group Ends  *******************


-- ************************************************
-- Bridge ports Configuration MIB
-- ************************************************

-- rtrBridge    OBJECT IDENTIFIER ::= { radRouter 7 }

        
rtrBridgePortConfigTable  OBJECT-TYPE     
       SYNTAX  SEQUENCE OF RtrBridgePortConfigEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
           "Table of the bridge ports" 
      ::= { rtrBridge 1 }

rtrBridgePortConfigEntry  OBJECT-TYPE     
       SYNTAX  RtrBridgePortConfigEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
           "Each entry defines a bridge port " 
       INDEX { rtrBridgePortCIndex }
      ::= { rtrBridgePortConfigTable 1 }

RtrBridgePortConfigEntry ::= SEQUENCE {
        rtrBridgePortCIndex
                Integer32,
        rtrBridgePortCIf
                Integer32,
        rtrBridgePortCStatus
                RowStatus
        }



rtrBridgePortCIndex OBJECT-TYPE
        SYNTAX  Integer32
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
                "This is the index of the bridge port. It is the same
                 as 'dot1dBasePort' of the Bridge MIB."
        ::= {rtrBridgePortConfigEntry 1}

rtrBridgePortCIf OBJECT-TYPE
        SYNTAX  Integer32
        MAX-ACCESS  read-create
        STATUS  current
        DESCRIPTION
                "The config ifIndex the bridge port is sitting on. "
        ::= {rtrBridgePortConfigEntry 2}

rtrBridgePortCStatus OBJECT-TYPE
        SYNTAX  RowStatus
        MAX-ACCESS  read-create
        STATUS  current
        DESCRIPTION
          "The status of the RtrBridgePortConfigEntry.  
           Creating and destroying the bridge port is done by this
           variable."
        ::= {rtrBridgePortConfigEntry 3}

 
radRouterConfig  OBJECT IDENTIFIER  ::= { radRouter 9 }


-- The Router's Configuration Table

rtrConfigTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF RtrConfigEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
    "The Router's Configuration table."
    ::= {  radRouterConfig 1 }

rtrConfigEntry  OBJECT-TYPE
    SYNTAX      RtrConfigEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
    "An entry in the Router's Configuration table."
    INDEX   { rtrConfigIndex }
    ::= { rtrConfigTable 1 }

RtrConfigEntry ::=
	SEQUENCE { 
        rtrConfigIndex           		INTEGER,
		-- 2 is NOT used
		rtrConfigArpAgingTime			Integer32,
		-- 4 is NOT used
		rtrConfigClassifierTosMask		Integer32   	
    	}

rtrConfigIndex OBJECT-TYPE
    SYNTAX  INTEGER
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
    "This object indicates the Router's Index."
    ::= { rtrConfigEntry 1 }

-- { rtrConfigEntry 2 } is NOT used

rtrConfigArpAgingTime OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "ARP Aging Time."
    ::= { rtrConfigEntry 3 }

-- { rtrConfigEntry 4 } is NOT used

rtrConfigClassifierTosMask OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
    "This object indicates the Classifier's TOS Mask,
	 as follows:
	 0x1C for DTR			-- rfc795
     0x1E for Cisco
     0xE0 for Precedence	-- rfc795
     0xFC for Diffserv
     Else for Manual
	 ."
    ::= { rtrConfigEntry 5 }


-- { radRouterConfig 2 } is NOT used


-- The Router's Forwarding Table

rtrFwdTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF RtrFwdEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
    "The Router's Forwarding Table."
    ::= {  radRouterConfig 3 }

rtrFwdEntry  OBJECT-TYPE
    SYNTAX      RtrFwdEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
    "An entry in the Router's Forwarding table."
    INDEX   { rtrFwdIdx, rtrFwdIpAddress, 
    			rtrFwdIpMask, rtrFwdRuleIdx }
    ::= { rtrFwdTable 1 }

RtrFwdEntry ::=
	SEQUENCE { 
        rtrFwdIdx				Integer32,
        rtrFwdIpAddress			IpAddress,
		rtrFwdIpMask			IpAddress,
		rtrFwdRuleIdx			Integer32,
		rtrFwdRowStatus	  		RowStatus,
		rtrFwdNextHop			IpAddress,			
		rtrFwdIfIndex			Integer32,
		rtrFwdType				INTEGER,
		rtrFwdProto				INTEGER,
		rtrFwdEthQueue			Integer32,
		rtrFwdMetric1			Integer32
    	}

rtrFwdIdx OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
    "This object indicates the Router Index."
    ::= { rtrFwdEntry 1 }

rtrFwdIpAddress OBJECT-TYPE
    SYNTAX  IpAddress
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
    "This object indicates the Destination IP Address."
    ::= { rtrFwdEntry 2 }

rtrFwdIpMask OBJECT-TYPE
    SYNTAX  IpAddress
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
    "This object indicates the Mask IP address."
    ::= { rtrFwdEntry 3 }

rtrFwdRuleIdx OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
    "This object indicates the Rule's Number."
    ::= { rtrFwdEntry 4 }

rtrFwdRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
    "This object enables the user to 
     create/delete entries in this table.
     
     Entry of Type rtrFwdType = staticRouting(3)
	 are created by the user.
	 Only this type of entries can be deleted by the user.

	 Entry of Type rtrFwdType = interface(2)
	 are created/deleted automatically by the Agent
	 when the user creates/deletes an interface of the Router."
    ::= { rtrFwdEntry 5 }

rtrFwdNextHop OBJECT-TYPE
    SYNTAX  IpAddress
    MAX-ACCESS  read-create
    STATUS  current
    DESCRIPTION
    "This object indicates the IP Address of the Next Hop."
    ::= { rtrFwdEntry 6 }

rtrFwdIfIndex OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
    "This object indicates the Interface Index."
    ::= { rtrFwdEntry 7 }

rtrFwdType OBJECT-TYPE
    SYNTAX  INTEGER {
		other    (1), -- not specified by this MIB
		reject   (2), -- route which discards traffic
		local    (3), -- local interface
		remote   (4)  -- remote destination
		}
    MAX-ACCESS read-create
    STATUS   current
    DESCRIPTION
       "The type of route.  Note that local(3)  refers
       to  a route for which the next hop is the final
       destination; remote(4) refers to  a  route  for
       which  the  next  hop is not the final destina-
       tion.

       Routes which do not result in traffic forwarding or
       rejection should not be displayed even if the
       implementation keeps them stored internally.
	   
       reject (2) refers to a route which, if matched, discards
       the message as unreachable. This is used in some
       protocols as a means of correctly aggregating routes."
    ::= { rtrFwdEntry 8 }

rtrFwdProto OBJECT-TYPE
    SYNTAX   INTEGER {
		other	(1),  -- not specified
		local	(2),  -- local interface
  		netmgmt	(3),  -- static route
 		rip		(8),  -- Berkeley RIP or RIP-II
		lis		(41)  -- Logical IP Subnet
		}
    MAX-ACCESS read-only
    STATUS   current
    DESCRIPTION
	"The routing mechanism via which this route was
	learned.  Inclusion of values for gateway routing 
	protocols is not intended to imply that
	hosts should support those protocols."
    ::= { rtrFwdEntry 9 }

rtrFwdEthQueue OBJECT-TYPE
    SYNTAX  Integer32
    MAX-ACCESS  read-create
    STATUS  current
    DESCRIPTION
    "This object indicates the ETH Queue number."
    ::= { rtrFwdEntry 10 }

rtrFwdMetric1 OBJECT-TYPE
    SYNTAX   Integer32
    MAX-ACCESS read-create
    STATUS   current
    DESCRIPTION
	"The primary routing metric for this route.
	 The semantics of this metric are determined by
	 the routing-protocol specified in the route's
	 rtrFwdProto value. If this metric is not
	 used, its value should be set to -1."
    DEFVAL { -1 }
    ::= { rtrFwdEntry 11 }


-- ****************  Router Bridge Port Group Ends  *******************



-- Traps

rtrFACSViolation NOTIFICATION-TYPE
      OBJECTS  { rtrFACSFrameData, rtrFACSProtocolType }
      STATUS  current
      DESCRIPTION
	  "The trap is sent for every violation of a FACS filter."
      ::= { radSysRtrEvents 1 }

rtrSwDwnLoadTrap NOTIFICATION-TYPE
      OBJECTS  { fileName }
      STATUS  current
      DESCRIPTION
	  "The trap is sent after the tftp download of the software
	   and before the decompression and reset operations."
      ::= { radSysRtrEvents 2 }
-- 
-- file :v:\doc\rdv\mib\ver495\atm\layer2.txt
-- 
-- 
-- file: v:\doc\rdv\mib\ver495\atm\layer2.txt
-- 
--RTR-MIB  
--
--Last update: 25-Sep-2002
--By: Shay Harari 


-- ************************************************
-- Link Layer (layer 2)  MIB
-- ************************************************


atmLayer2  OBJECT IDENTIFIER  ::=  {radAtm 7}

 atmLayer2XVclTable OBJECT-TYPE
	SYNTAX SEQUENCE OF AtmLayer2XVclEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
    "This table is an extension of VCL table, which is created  
    for each LAN VCC."
	::= { atmLayer2 1 }

 atmLayer2XVclEntry OBJECT-TYPE
	SYNTAX AtmLayer2XVclEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
    "Conceptual row in atmVclTable.
    This table augments the RFC2515 VCL table."
 AUGMENTS { atmVclEntry }
	::= { atmLayer2XVclTable 1 }

 AtmLayer2XVclEntry ::= SEQUENCE {
	atmLayer2XVclConnMode       INTEGER,
    atmLayer2XVclGroupIdx       Integer32 
 }

 atmLayer2XVclConnMode OBJECT-TYPE
	SYNTAX INTEGER { 
	              main   (1), 
	              sub    (2) 
				   }
	MAX-ACCESS read-create
	STATUS current
	DESCRIPTION
    "Each valid LAN VCC is either Main or Sub. 
	This parameter is configured only once on creation of a LAN VCC.
	It can not be changed after creation. In order to change the Mode, 
	user should delete the connection and create a new one.
		  
    main - A LAN VCC, which holds its own bridge port. 
           Bridge forwarding and Bridge learning is performed only on Main 
	       VCCs.
	       For working on a transparent bridge, that doesn't perform
	       layer 2 priority mapping, a Main VCC should be opened, which 
		   is the default connection Mode. 
		   When working with layer 2 priority, a group of LAN VCCs should
		   be configured, where each group will be associated with only 
		   one Main VCC.
		   A specific Main can not be used by more than one group. 
	sub  - A LAN VCC is not part of the bridging mechanism. 
		   A Sub VCC automatically inherit some general definitions from
		   Main VCC of its group: ATM Slot/Port and LAN Slot/Port.
		   Max number of Sub VCCs allowed per group is:  
		   [Number of Priorities - 1]."
	::= { atmLayer2XVclEntry 1 }

 atmLayer2XVclGroupIdx OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
	"The group identifier.
	A VCC Group identifier = 0 if the VCC was not associated with a 
	group yet.
	This value is updated according to the group identifier set by 
	atmLayer2GroupTable."
	::= { atmLayer2XVclEntry 2 }

 atmLayer2GroupTable OBJECT-TYPE
	SYNTAX SEQUENCE OF AtmLayer2GroupEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
	"This table contains groups and their members.
	A group is a bundle of VCCs, which acts as different queues.
	Main and Sub VCCs should have the same ATM slot and port,
	and the same LAN slot and port.
    Each group contains: 1 to <number of priorities> VCCs."
	::= { atmLayer2 2 }

 atmLayer2GroupEntry OBJECT-TYPE
	SYNTAX AtmLayer2GroupEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
	"Conceptual row in atmLayer2GroupTable.
	The indexes: ifIndex, atmVclVpi and atmVclVci indicate 
	the Network ATM End-Point.
	Upon a group creation, one Main VCC must be added first.
	After the group was created, Sub VCCs may be added to the group."
 INDEX { atmLayer2GroupIdx, ifIndex, atmVclVpi, atmVclVci }
	::= { atmLayer2GroupTable 1 }

 AtmLayer2GroupEntry ::= SEQUENCE {
    atmLayer2GroupIdx          Integer32, 
    atmLayer2GroupRowStatus    RowStatus, 
    atmLayer2GroupConnMode     INTEGER, 
    atmLayer2GroupConnPriority OCTET STRING,
    atmLayer2GroupName         SnmpAdminString 
 }

 atmLayer2GroupIdx OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
	"The group identifier. 
	0 is not a valid index."
	::= { atmLayer2GroupEntry 1 }

 atmLayer2GroupRowStatus OBJECT-TYPE
	SYNTAX RowStatus
	MAX-ACCESS read-create
	STATUS current
	DESCRIPTION
	"Creation/Deletion of rows in the table, and indication of the 
	entry's status."
	::= {atmLayer2GroupEntry 2 }
 
 atmLayer2GroupConnMode OBJECT-TYPE
	SYNTAX INTEGER { 
	              main (1), 
	              sub  (2) 
				   }
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
	"Each valid LAN VCC is either Main or Sub as configured in 
	atmLayer2XVclTable."
	::= { atmLayer2GroupEntry 3 }

 atmLayer2GroupConnPriority OBJECT-TYPE
    SYNTAX OCTET STRING (SIZE (1))
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
	"This parameter is configured by atmLayer2PriorityRx from 
	atmLayer2PriorityTable.
	Each bit in the Octet represents a specific priority as follows:
		  
		                  
             MSB 7  6  5  4  3  2  1  0 LSB	  -> Priorities
                 |____________________|
                 1  0  0  1  0  0  0  1		  ->	  Value
		  
	In this example, a certain VCC has several priorities: 0, 4 and 7."
	::= { atmLayer2GroupEntry 4 }

 atmLayer2GroupName OBJECT-TYPE
	SYNTAX SnmpAdminString (SIZE (1..32))
	MAX-ACCESS read-create
	STATUS current
	DESCRIPTION
	"Group name. Configured by the user.
	The name is unique per system.
	For atmLayer2GroupIdx=0, the name will be null."
	::= { atmLayer2GroupEntry 5 }


 atmLayer2PriorityTable OBJECT-TYPE
	SYNTAX SEQUENCE OF AtmLayer2PriorityEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
	"This table maps all priorities inside a group.
	Several priorities might be mapped to the same VCC. 
	Upon priority change, the agent will update the VCCs of the 
	changed priority in this table, and will update	-
	atmLayer2GroupConnPriority parameter of both former and new owners 
	of the changed priority.
	Changing a VCC value is actually a change of three parameters
	simultaneously: atmLayer2PriorityIfIndex, atmLayer2PriorityVclVpi
	and atmLayer2PriorityVclVci. Otherwise, the set will be rejected,
	since there might be that such VCC doesn't exist in the specific
	group."
	::= { atmLayer2 3 }

 atmLayer2PriorityEntry OBJECT-TYPE
	SYNTAX AtmLayer2PriorityEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
	"Conceptual row in atmLayer2PriorityTable.
	Each entry is a Network ATM End-Point per priority.
	Upon a group creation, all priorities are mapped to the Main VCC. 
	Number of entries per group is according to the number of 
	priorities enabled. (For example, for Max priorities = 8,  
	the agent will create 8 entries)."
    INDEX { atmLayer2PriorityGroupIdx, atmLayer2PriorityRx }
	::= { atmLayer2PriorityTable 1 }

 AtmLayer2PriorityEntry ::= SEQUENCE {
    atmLayer2PriorityGroupIdx        Integer32, 
    atmLayer2PriorityRx              INTEGER, 
	atmLayer2PriorityIfIndex	     InterfaceIndex,
    atmLayer2PriorityVclVpi          Integer32,
    atmLayer2PriorityVclVci          Integer32        
 }

 atmLayer2PriorityGroupIdx OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
	"The group identifier." 
	::= { atmLayer2PriorityEntry 1 }

 atmLayer2PriorityRx OBJECT-TYPE
	SYNTAX INTEGER (1..8)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
	"The priority values.
	The used values are 0-7, but since this value is part of the index
	of the table, and in order to avoid '0' as an index, the index syntax 
	is 1..8, but the real value is atmLayer2PriorityRx-1: 
		  0 - for Low priority. 
		  7 - for High priority."
	::= { atmLayer2PriorityEntry 2 }

 atmLayer2PriorityIfIndex OBJECT-TYPE
	SYNTAX InterfaceIndex
	MAX-ACCESS read-create
	STATUS current
	DESCRIPTION
	"ATM ifIndex of the network End-Point."
	::= { atmLayer2PriorityEntry 3 }
 
 atmLayer2PriorityVclVpi OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS read-create
	STATUS current
	DESCRIPTION
	"Vpi of the network End-Point."
	::= { atmLayer2PriorityEntry 4 }

 atmLayer2PriorityVclVci OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS read-create
	STATUS current
	DESCRIPTION
	"Vci of the network End-Point."
	::= { atmLayer2PriorityEntry 5 }

atmLayer2GroupIndexNext  OBJECT-TYPE
          SYNTAX         Integer32 (0..2147483647)
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "This object contains an appropriate value to
            be used for atmLayer2GroupIdx when creating
            entries in the atmLayer2GroupTable. The value
            0 indicates that no unassigned entries are
            available. To obtain the atmLayer2GroupIdx
            value for a new entry, the manager gets 
            the current value of this object. The next index
            will be of the first unassigned entry. It will be 
            provided by checking the assigned entries."
          ::= { atmLayer2 4 }

--VLAN
 atmLayer2CfgTable OBJECT-TYPE
	SYNTAX SEQUENCE OF AtmLayer2CfgEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
	"Bridge configuration Table. This table supports multi-bridge 
	and bridge features within an ATM device."
	::= { atmLayer2 5 }

 atmLayer2CfgEntry OBJECT-TYPE
	SYNTAX AtmLayer2CfgEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
	"Conceptual row in atmLayer2CfgTable.
	Each entry in this table contains the bridging attributes for
	both Ethernet and ATM sides.
	The interface index is the Ethernet port interface.

	For Ace52: this object represents the Bridge ifIndex."
 INDEX { ifIndex }
	::= { atmLayer2CfgTable 1 }

 AtmLayer2CfgEntry ::= SEQUENCE {
    atmLayer2CfgBridgingMode            INTEGER, 
    atmLayer2CfgVlanMode                INTEGER, 
    atmLayer2CfgAtmAcceptableFrameType  INTEGER,
    atmLayer2CfgAtmIngressFiltering     TruthValue,
    atmLayer2CfgAtmTxFrameType          INTEGER,
    atmLayer2CfgEthAcceptableFrameType  INTEGER,
    atmLayer2CfgBridgeAction            INTEGER,
    atmLayer2CfgLearningMode            INTEGER,
	atmLayer2CfgAgingTime               Integer32	
 }

 atmLayer2CfgBridgingMode OBJECT-TYPE
               SYNTAX  INTEGER {
                       accessOnly(1),
                       accessAndSwitching (2)
               }
 	           MAX-ACCESS  read-write
               STATUS  current
               DESCRIPTION
               "Bridging mode can be one of the following: 
	            ATM <> Ethernet - Bridging is between the Ethernet 
	            port and the ATM port (there is no bridging between VCs).
	            ATM <> Ethernet + ATM - Bridging is done both between 
	            the Ethernet port and the ATM port and also between VCs."
	::= { atmLayer2CfgEntry 1 }

 atmLayer2CfgVlanMode OBJECT-TYPE
               SYNTAX  INTEGER {
                       disable   (2),
                       enable    (3)
               }
 	           MAX-ACCESS  read-write
               STATUS  current
               DESCRIPTION
               "VLAN Mode. Upon Mode changing, all LAN VCCs will be deleted
               by the agent from all tables that include LAN VCCs."
	::= { atmLayer2CfgEntry 2 }
 
 atmLayer2CfgAtmAcceptableFrameType OBJECT-TYPE
	SYNTAX INTEGER { 
	              notApplicable       (1),
	              admitAll            (2), 
	              admitOnlyVlanTagged (3), 
	              admitOnlyUnTagged   (4) 
				   }
 	           MAX-ACCESS  read-write
               STATUS  current
               DESCRIPTION
               "The Frame Type that will be acceptable by the VCCs that 
               are associated with this Ethernet port.
               Frames which don't match the selected type will be discarded.
                
               admitAll -            all frames will be accepted.
               admitOnlyVlanTagged - only Tagged frames will be accepted.
               admitOnlyUnTagged   - only unTagged frames will be accepted."
	::= { atmLayer2CfgEntry 3 }

 atmLayer2CfgAtmIngressFiltering OBJECT-TYPE
              SYNTAX      TruthValue
              MAX-ACCESS  read-write
              STATUS      current
              DESCRIPTION
              "For the VCCs that are associated with this Ethernet port, 
              when this is true(1) the device will discard incoming
              frames for VLANs which do not include this Port in its
              Member set.  When false(2), the port will accept all
              incoming frames."
	::= { atmLayer2CfgEntry 4 }

 atmLayer2CfgAtmTxFrameType OBJECT-TYPE
	SYNTAX INTEGER { 
	              notApplicable(1),
	              unTagged (2), 
	              tagged   (3) 
				   }
 	           MAX-ACCESS  read-write
               STATUS  current
               DESCRIPTION
               "The Frame Type that will be transmitted by the VCCs that 
               are associated with this Ethernet port. 
               
               unTagged -      The transmitted frames will be unTagged.
               tagged -        The transmitted frames will be Tagged."
	::= { atmLayer2CfgEntry 5 }

 atmLayer2CfgEthAcceptableFrameType OBJECT-TYPE
	SYNTAX INTEGER { 
	              notApplicable       (1),
	              admitAll            (2), 
	              admitOnlyVlanTagged (3), 
	              admitOnlyUnTagged   (4) 
				   }
 	           MAX-ACCESS  read-write
               STATUS  current
               DESCRIPTION
               "The Frame Type that this Ethernet port will accept.
			   (for ACE-52: the Frame Type that this Bridge will accept)
			   This parameter is notApplicable for atmLayer2VlanMode=disable.
               Frames which don't match the selected type will be discarded.
                
               admitAll -            all frames will be accepted.
               admitOnlyVlanTagged - only Tagged frames will be accepted.
               admitOnlyUnTagged -   only unTagged frames will be accepted."
	::= { atmLayer2CfgEntry 6 }

 atmLayer2CfgBridgeAction OBJECT-TYPE
    SYNTAX  INTEGER {
       deleteLanTable   (7),
	   noOp             (255)
     }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"This object enables to perform the	specified action on the 
	selected port."
	::= { atmLayer2CfgEntry 7 }

 atmLayer2CfgLearningMode OBJECT-TYPE
    SYNTAX  INTEGER {
       svl   (1),
       ivl   (2)
     }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
	"This object specifies the mode of the learning process of a bridge.
	svl - Shared VLAN process. If an individual MAC Address is learned 
	      in one VLAN, this information is used in forwarding decisions
	      taken for that address for all other VLANs.
	ivl - Independent VLAN process. If an individual MAC Address is learned 
	      in one VLAN, this information is not used in forwarding decisions
	      taken for that address for all other VLANs."
	::= { atmLayer2CfgEntry 8 }

atmLayer2CfgAgingTime OBJECT-TYPE
    SYNTAX Integer32 
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
    "The timeout period in seconds for aging out
     dynamically learned forwarding information."
    ::= { atmLayer2CfgEntry 9 }
-- 
-- file :v:\doc\rdv\mib\ver470\atm\frAtm.txt
-- 
-- 
-- file: v:\doc\rdv\mib\ver470\atm\frAtm.txt
-- 
--FR-ATM-IWF-X-MIB  
--
--Last update: 28-Feb-2001
--By: Ilana Schvetz 

 
--atmSuPortFr     OBJECT IDENTIFIER ::= { atmSuPort 4 }
radAtmFr  OBJECT IDENTIFIER  ::=  {radAtm 8}
 
 frAtmIwfXConnectionTable OBJECT-TYPE
	SYNTAX SEQUENCE OF FrAtmIwfXConnectionEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
    "This table is an extension of frAtmIwfXConnectionTable from
    RFC2955."
	::= { radAtmFr 1 }

 frAtmIwfXConnectionEntry OBJECT-TYPE
	SYNTAX FrAtmIwfXConnectionEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
    "Conceptual row in frAtmIwfXConnectionTable.
    This table augments the RFC2955."
 AUGMENTS { frAtmIwfConnectionEntry }
	::= { frAtmIwfXConnectionTable 1 }

 FrAtmIwfXConnectionEntry ::= SEQUENCE {
                 frAtmIwfXConnMode         INTEGER,
                 frAtmIwfXConnSscsDlci     Integer32
 }

         frAtmIwfXConnMode OBJECT-TYPE
             SYNTAX      INTEGER { service(1), network(2) }
             MAX-ACCESS  read-create
             STATUS      current
             DESCRIPTION
                     "FR IWF Mode. 
                     service - Service InterWorking (FRF.8),
                     network - Network InterWorking (FRF.5)."
	         ::= { frAtmIwfXConnectionEntry 1 }

         frAtmIwfXConnSscsDlci OBJECT-TYPE
             SYNTAX      Integer32
             MAX-ACCESS  read-create
             STATUS      current
             DESCRIPTION
                     "This parameter is relevant for 
                     frAtmIwfXConnMode=network (FRF.5) only.
                     This parameter allow configuration of the 
                     FR SSCS DLCI that is transferred to the 
                     remote FR unit."
	         ::= { frAtmIwfXConnectionEntry 2 }

-- 
-- file :v:\doc\rdv\mib\ver495\atm\radaal5.txt
-- 
-- 
-- file :v:\doc\rdv\mib\ver495\atm\radaal5.txt
-- 
--Last update: 19-Nov-2002 by Ilana Schvetz


--     ATM-X-MIB DEFINITIONS ::= BEGIN
--
--atmGen  OBJECT IDENTIFIER  ::=  {radAtm 2}

--atmPerfHistory  OBJECT IDENTIFIER  ::=  {atmGen 1}

--atmIfPerformance  OBJECT IDENTIFIER  ::=  {atmPerfHistory 1}

     -- AAL5 Virtual Channel Connection Performance Statistics

     -- Table

     -- This table contains the AAL5 extension
     -- performance statistics of a VCC at the
     -- interface associated with an AAL5 entity in an ATM
     -- host or ATM switch.

     aal5VccXTable        OBJECT-TYPE
          SYNTAX         SEQUENCE OF Aal5VccXEntry
          MAX-ACCESS     not-accessible
          STATUS         current
          DESCRIPTION
           "This table is an extension to AAL5 VCC Table."
          ::= { atmIfPerformance 4 }

     aal5VccXEntry        OBJECT-TYPE
          SYNTAX         Aal5VccXEntry
          MAX-ACCESS     not-accessible
          STATUS         current
          DESCRIPTION
           "This list contains the additional AAL5 VCC
            performance parameters and is indexed
            by ifIndex values of AAL5 interfaces
            and the associated VPI/VCI values."
          AUGMENTS { aal5VccEntry }
          ::= { aal5VccXTable 1 }

     Aal5VccXEntry    ::= SEQUENCE  {
          aal5VccInFrames     Counter32,
          aal5VccOutFrames    Counter32,
		  aal5VccUnknownProtocolFrames	 Counter32
               }

     aal5VccInFrames  OBJECT-TYPE
          SYNTAX         Counter32
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "The number of frames received via this interface."
          ::= { aal5VccXEntry 1 }

     aal5VccOutFrames OBJECT-TYPE
          SYNTAX         Counter32
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "The total number of frames transmitted out of the
           interface."
          ::= { aal5VccXEntry 2 }

    aal5VccUnknownProtocolFrames OBJECT-TYPE
          SYNTAX         Counter32
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "The number of frames that were discarded due to unsupported
            protocol encapsulation on this VCC."
          ::= { aal5VccXEntry 3 }


     aal5VccCurrentTable        OBJECT-TYPE
          SYNTAX         SEQUENCE OF Aal5VccCurrentEntry
          MAX-ACCESS     not-accessible
          STATUS         current
          DESCRIPTION
           "The AAL5 Current table."
          ::= { atmIfPerformance 5 }

     aal5VccCurrentEntry        OBJECT-TYPE
          SYNTAX         Aal5VccCurrentEntry
          MAX-ACCESS     not-accessible
          STATUS         current
          DESCRIPTION
           "An entry in the AAL5 Current table."
          INDEX { ifIndex, aal5VccVpi, aal5VccVci }
           ::= { aal5VccCurrentTable 1 }

     Aal5VccCurrentEntry    
     ::= SEQUENCE  {
          aal5VccCurrentInFrames     
             Gauge32,
          aal5VccCurrentOutFrames    
             Gauge32,
		  aal5VccCurrentUnknownProtocolFrames	 
		     Gauge32,
		  aal5VccCurrentCrcErrors	 
		     Gauge32,
		  aal5VccCurrentLengthError	 
		     Gauge32,
		  aal5VccCurrentInputCongestionDropped
			 Gauge32,
		  aal5VccCurrentOutputCongestionDropped
			 Gauge32
               }

aal5VccCurrentInFrames OBJECT-TYPE
      SYNTAX      Gauge32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
	  "The counter associated with the number of received frames, 
	  encountered by the AAL5 interface in the current 15 minute 
	  interval."
    ::= { aal5VccCurrentEntry 1 }

aal5VccCurrentOutFrames OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of transmitted frames, 
	  encountered by the AAL5 interface in the current 15 minute 
	  interval."
      ::= { aal5VccCurrentEntry 2 }

aal5VccCurrentUnknownProtocolFrames OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of frames that were 
	  discarded due to unsupported protocol encapsulation, 
	  encountered by the AAL5 interface in the current 15 minute 
	  interval."
      ::= { aal5VccCurrentEntry 3 }

aal5VccCurrentCrcErrors OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of AAL5 CPCS PDUs 
	  received with	CRC-32 errors, encountered by the AAL5 
	  interface in the current 15 minute interval."
      ::= { aal5VccCurrentEntry 4 }

aal5VccCurrentLengthError OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of received frames 
	  with length error, encountered by the AAL5 interface in the 
	  current 15 minute interval."
      ::= { aal5VccCurrentEntry 5 }

aal5VccCurrentInputCongestionDropped OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of 
	   dropped frames due to congestion, encountered by 
	   the AAL5 interface on the Receive direction 
	   in the current 15 minute interval."
      ::= { aal5VccCurrentEntry 6 }

aal5VccCurrentOutputCongestionDropped OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of 
	   dropped frames due to congestion, encountered by 
	   the AAL5 interface on the Transmit direction 
	   in the current 15 minute interval."
      ::= { aal5VccCurrentEntry 7 }


-- Interval Table 
 
     aal5VccIntervalTable        OBJECT-TYPE
          SYNTAX         SEQUENCE OF Aal5VccIntervalEntry
          MAX-ACCESS     not-accessible
          STATUS         current
          DESCRIPTION
           "The AAL5 Interval table."
          ::= { atmIfPerformance 6 }

     aal5VccIntervalEntry        OBJECT-TYPE
          SYNTAX         Aal5VccIntervalEntry
          MAX-ACCESS     not-accessible
          STATUS         current
          DESCRIPTION
           "An entry in the AAL5 Interval table."
          INDEX { ifIndex, aal5VccVpi, aal5VccVci, aal5VccIntervalNumber }
           ::= { aal5VccIntervalTable 1 }

     Aal5VccIntervalEntry    
     ::= SEQUENCE  {
          aal5VccIntervalNumber     
             Integer32,
          aal5VccIntervalInFrames     
             Gauge32,
          aal5VccIntervalOutFrames    
             Gauge32,
		  aal5VccIntervalUnknownProtocolFrames	 
		     Gauge32,
		  aal5VccIntervalCrcErrors	 
		     Gauge32,
		  aal5VccIntervalLengthError	 
		     Gauge32,
		  aal5VccIntervalInputCongestionDropped
			 Gauge32,
		  aal5VccIntervalOutputCongestionDropped
			 Gauge32
               }

aal5VccIntervalNumber OBJECT-TYPE
    SYNTAX  Integer32 (1..96)
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
        "A number between 1 and 96, where 1 is the most
         recently completed 15 minute interval and 96 is
         the least recently completed 15 minutes interval
         (assuming that all 96 intervals exist)."
    ::= { aal5VccIntervalEntry 1 }


aal5VccIntervalInFrames OBJECT-TYPE
      SYNTAX      Gauge32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
	  "The counter associated with the number of received frames, 
	  encountered by the AAL5 interface in one of the previous 
	  96, individual 15 minute, intervals."
    ::= { aal5VccIntervalEntry 2 }

aal5VccIntervalOutFrames OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of transmitted frames, 
	  encountered by the AAL5 interface in in one of the previous 
	  96, individual 15 minute, intervals."
      ::= { aal5VccIntervalEntry 3 }

aal5VccIntervalUnknownProtocolFrames OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of frames that were 
	  discarded due to unsupported protocol encapsulation, 
	  encountered by the AAL5 interface in one of the previous 
	  96, individual 15 minute, intervals."
      ::= { aal5VccIntervalEntry 4 }

aal5VccIntervalCrcErrors OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of AAL5 CPCS PDUs 
	  received with	CRC-32 errors, encountered by the AAL5 
	  interface in one of the previous 96, individual 15 minute, 
	  intervals."
      ::= { aal5VccIntervalEntry 5 }

aal5VccIntervalLengthError OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of received frames 
	  with length error, encountered by the AAL5 interface in one 
	  of the previous 96, individual 15 minute, intervals."
      ::= { aal5VccIntervalEntry 6 }

aal5VccIntervalInputCongestionDropped OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of dropped frames 
	  due to a congestion, encountered by the AAL5 interface on 
	  the Receive direction in one of the previous 96, individual 
	  15 minute, intervals"
      ::= { aal5VccIntervalEntry 7 }

aal5VccIntervalOutputCongestionDropped OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of dropped frames 
	  due to a congestion, encountered by the AAL5 interface on 
	  the Transmit direction in one of the previous 96, individual 
	  15 minute, intervals"
      ::= { aal5VccIntervalEntry 8 }


-- END

-- 
-- file :v:\doc\rdv\mib\ver495\ethif.txt
-- 
--01/08/2000
--By: Smadar Tauber
--s:\doc\rdv\mib\ver485\ethIf.txt
--File: ethIf.txt


--EthIf MIB - separated from mpmx.txt

--diverseIfWanGen	OBJECT IDENTIFIER ::= {wanGen 6}

--Last update: 27-Jan-2003 by Shay Hararim


--
-- diverseIf - diverse NON-WAN interfaces of WAN products 	
--

--Ethernet Interface


ethIf OBJECT IDENTIFIER ::= {diverseIfWanGen 1}	  --Ethernet Interface

ethIfTable OBJECT-TYPE
      SYNTAX SEQUENCE OF EthIfEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "A table."
	::=  { ethIf 1}

ethIfEntry OBJECT-TYPE
      SYNTAX EthIfEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION  "An entry in table."
	INDEX {ethIfIdx}
      ::= {ethIfTable 1}

EthIfEntry ::=
      SEQUENCE {
      ethIfIdx                Integer32,
      ethMode                 INTEGER,
      ethBridgingMode         INTEGER,
	  ethEncapsulationCRCMode INTEGER,
	  ethBackPressure		  INTEGER,
	  ethLimit4				  INTEGER,
	  ethSkipInitReset		  INTEGER,
	  ethMulticastBlock	  	  INTEGER,
	  ethBroadcastBlock	  	  INTEGER,
	  ethSpeed				  INTEGER,
      ethRip2                 INTEGER,
      ethPortPriority         INTEGER,
	  ethPortMngEnable		  INTEGER,
	  ethFlowCtrlMacAddress  MacAddress

	 		      }

ethIfIdx     OBJECT-TYPE
      SYNTAX  Integer32
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
      "A unique index of the ethernet interface/port."
      ::=  {ethIfEntry 1}

ethMode    OBJECT-TYPE
      SYNTAX  INTEGER
        {
          halfDuplex  (1),
          fullDuplex  (2),
		  notApplicable(255)
     }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the Ethernet mode of operation."
      ::=  {ethIfEntry 2}

ethBridgingMode  OBJECT-TYPE
      SYNTAX  INTEGER
      {
         filtered    (1),
         transparent (2)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates the bridging mode of the Ethernet
       interface. "
      ::=  {ethIfEntry 3}

ethEncapsulationCRCMode  OBJECT-TYPE
      SYNTAX  INTEGER
      {
			  notApplicable (1),
			  withCRC	    (2),
			  withoutCRC	(3)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
       "This object define the encapsulation type requested for the
			  Ethernet interface. It indicates if we transfer the Ethernet
				frame to the other side with or without the CRC. "
      ::=  {ethIfEntry 4}

ethBackPressure  OBJECT-TYPE
      SYNTAX  INTEGER
      {
			  notApplicable (1),
			  disable	    (2),
			  enable		(3)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
        "This parameter defines whether to enable or disable Back pressure.
         Back Pressure is a flow control parameter. "
      ::=  {ethIfEntry 5}
      
ethLimit4  OBJECT-TYPE
      SYNTAX  INTEGER
      {
			  notApplicable (1),
			  disable	    (2),
			  enable		(3)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
       "This parameter determine the Back off algorithm mode.
        Every 4 following collisions the Framer will be thrown out
        (4 times more than usuall)."
      ::=  {ethIfEntry 6}
      
ethSkipInitReset  OBJECT-TYPE
      SYNTAX  INTEGER
      {
			  notApplicable (1),
			  notSkip	    (2),
			  skip			(3)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
       "This parameter defines whether read status on reset. "
      ::=  {ethIfEntry 7}
      
ethMulticastBlock  OBJECT-TYPE
      SYNTAX  INTEGER
      {
			  notApplicable (1),
			  unBlock	    (2),
			  block			(3)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
       "This parameter defines whether to send multicast message to WAN from LAN or not. "
      ::=  {ethIfEntry 8}

ethBroadcastBlock  OBJECT-TYPE
      SYNTAX  INTEGER
      {
			  notApplicable (1),
			  unBlock	    (2),
			  block			(3)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
       "This parameter defines whether to send broadcast message to WAN from LAN or not."
      ::=  {ethIfEntry 9}

ethSpeed  OBJECT-TYPE
      SYNTAX  INTEGER
      {
			  notApplicable (1),
			  s10Mbps	    (2),
			  s100Mbps		(3)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
       "This parameter defines the line speed."
      ::=  {ethIfEntry 10}


ethRip2  OBJECT-TYPE
      SYNTAX  INTEGER
      {
			  notApplicable (1),
			  no    	    (2),
              yes           (3)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
       "This parameter defines whether to send RIP II  message 
       to WAN from LAN or not"
      ::=  {ethIfEntry 11}

ethPortPriority  OBJECT-TYPE
      SYNTAX  INTEGER
      {
              notApplicable (1),
              none    	    (2),
              fixed         (3)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
       "This parameter defines if priority is to   
        be considered for this Port."
      ::=  {ethIfEntry 12}

ethPortMngEnable  OBJECT-TYPE
      SYNTAX  INTEGER
      {
              notApplicable (1),
              no	  	    (2),
      		  yes	        (3)
      }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
       "This parameter defines whether management data can pass through this Port."
      ::=  {ethIfEntry 13}

ethFlowCtrlMacAddress OBJECT-TYPE
      SYNTAX  MacAddress 
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "In case of flow control - transmit frame with this specific MAC address
       to inform the other end to stop sending frames.
       Default: 01.80.C2.00.00.01."     
      ::= {ethIfEntry 14}
  



ethIfPerformance OBJECT IDENTIFIER ::= {ethIf 2}

ethIfCurrentTable OBJECT-TYPE
      SYNTAX SEQUENCE OF EthIfCurrentEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION
         "The Ethernet Current table."
	  ::=  { ethIfPerformance 1}

ethIfCurrentEntry OBJECT-TYPE
      SYNTAX EthIfCurrentEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION
         "An entry in the Ethernet Current table."
	INDEX {ethIfCurrentIndex}
      ::= {ethIfCurrentTable 1}

EthIfCurrentEntry ::=
      SEQUENCE {
      ethIfCurrentIndex
           Integer32,
	  ethIfCurrentStatus
	       OCTET STRING,
      ethIfCurrentInFrames
      	   Gauge32,
      ethIfCurrentInOctets
      	   Gauge32,
      ethIfCurrentAlignmentErrors
      	   Gauge32,
      ethIfCurrentFCSErrors
      	   Gauge32,
      ethIfCurrentLengthError
      	   Gauge32,
      ethIfCurrentOutFrames
      	   Gauge32,
      ethIfCurrentOutOctets
      	   Gauge32,
      ethIfCurrentSingleCollisionFrames
      	   Gauge32,
      ethIfCurrentMultipleCollisionFrames
           Gauge32,
      ethIfCurrentDeferredTransmissions
      	   Gauge32,
      ethIfCurrentLateCollisions
      	   Gauge32,
      ethIfCurrentCarrierSenseErrors
      	   Gauge32,
	  ethIfCurrentInputCongestionDropped
      	   Gauge32,
	  ethIfCurrentOutputCongestionDropped
      	   Gauge32
      }

ethIfCurrentIndex OBJECT-TYPE
      SYNTAX      Integer32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
        "The index of the Ethernet interface. 
        It may be ifIndex."
     ::= { ethIfCurrentEntry 1 }

ethIfCurrentStatus OBJECT-TYPE
	 SYNTAX OCTET STRING  (SIZE (4))
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
      "The statuses of the current interval:
         0 - Valid.
         1 - redundantLinkSwitch - the link has been switched 
             by a redundancy mechanism.
         2 - discontinuity - module was partialy out.
         4 - notValid - module is out."
      ::= { ethIfCurrentEntry 2 }

ethIfCurrentInFrames OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of received frames, 
	  encountered by the Ethernet interface in the current 15 minute 
	  interval."
      ::= { ethIfCurrentEntry 3 }

ethIfCurrentInOctets OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of received octets, 
	  encountered by the Ethernet interface in the current 15 minute 
	  interval."
      ::= { ethIfCurrentEntry 4 }

ethIfCurrentAlignmentErrors OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of received frames, 
	  which are not complete (The result of dividing the number 
	  of bits by 8 is not an Integer), encountered by the Ethernet 
	  interface in the current 15 minute interval."
      ::= { ethIfCurrentEntry 5 }

ethIfCurrentFCSErrors OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of received frames 
	  that didn't pass the FCS test, encountered by the Ethernet 
	  interface in the current 15 minute interval."
      ::= { ethIfCurrentEntry 6 }

ethIfCurrentLengthError OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of received frames 
	  with length error, encountered by the Ethernet interface in 
	  the current 15 minute interval."
      ::= { ethIfCurrentEntry 7 }

ethIfCurrentOutFrames OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of transmitted frames, 
	  encountered by the Ethernet interface in the current 15 minute 
	  interval."
      ::= { ethIfCurrentEntry 8 }

ethIfCurrentOutOctets OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of transmitted octets, 
	  encountered by the Ethernet interface in the current 15 minute 
	  interval."
      ::= { ethIfCurrentEntry 9 }

ethIfCurrentSingleCollisionFrames OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of successfully
	  transmitted frames for which transmission was inhibited by
	  exactly one collision, encountered by the Ethernet interface 
	  in the current 15 minute interval."
      ::= { ethIfCurrentEntry 10 }

ethIfCurrentMultipleCollisionFrames OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of successfully
	  transmitted frames for which transmission was inhibited by
	  more than one collision, encountered by the Ethernet interface 
	  in the current 15 minute interval."
      ::= { ethIfCurrentEntry 11 }

ethIfCurrentDeferredTransmissions OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of transmitted frames 
	  for which the first transmission attempt was delayed due to a 
	  busy media, encountered by the Ethernet interface in the 
	  current 15 minute interval."
      ::= { ethIfCurrentEntry 12 }

ethIfCurrentLateCollisions OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of times that a 
	  collision was detected later than the first 64 bytes of the 
	  frame, encountered by the Ethernet interface in the current 
	  15 minute interval."
      ::= { ethIfCurrentEntry 13 }

ethIfCurrentCarrierSenseErrors OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of times that the 
	  carrier sense condition was lost or never asserted when 
	  attempting to transmit a frame, encountered by the Ethernet 
	  interface in the current 15 minute interval."
      ::= { ethIfCurrentEntry 14 }

ethIfCurrentInputCongestionDropped OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of frames dropped 
	  due to lack of buffers in ingress pool, encountered by 
	  the Ethernet interface in the current 15 minute interval."
      ::= { ethIfCurrentEntry 15 }

ethIfCurrentOutputCongestionDropped OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of dropped frames 
	  due to a congestion, encountered by the Transmit direction 
	  to the Ethernet interface in the current 15 minute interval."
      ::= { ethIfCurrentEntry 16 }


--Interval Table

ethIfIntervalTable OBJECT-TYPE
      SYNTAX SEQUENCE OF EthIfIntervalEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION
         "The Ethernet Interval table."
	  ::=  { ethIfPerformance 2 }

ethIfIntervalEntry OBJECT-TYPE
      SYNTAX EthIfIntervalEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION
         "An entry in the Ethernet Interval table."
    INDEX { ethIfIntervalIndex, ethIfIntervalNumber }
      ::= {ethIfIntervalTable 1}

EthIfIntervalEntry ::=
      SEQUENCE {
      ethIfIntervalIndex
           Integer32,
      ethIfIntervalNumber
           Integer32,
	  ethIfIntervalStatus
	       OCTET STRING,
      ethIfIntervalInFrames
      	   Gauge32,
      ethIfIntervalInOctets
      	   Gauge32,
      ethIfIntervalAlignmentErrors
      	   Gauge32,
      ethIfIntervalFCSErrors
      	   Gauge32,
      ethIfIntervalLengthError
      	   Gauge32,
      ethIfIntervalOutFrames
      	   Gauge32,
      ethIfIntervalOutOctets
      	   Gauge32,
      ethIfIntervalSingleCollisionFrames
      	   Gauge32,
      ethIfIntervalMultipleCollisionFrames
           Gauge32,
      ethIfIntervalDeferredTransmissions
      	   Gauge32,
      ethIfIntervalLateCollisions
      	   Gauge32,
      ethIfIntervalCarrierSenseErrors
      	   Gauge32,
	  ethIfIntervalInputCongestionDropped
		   Gauge32,
	  ethIfIntervalOutputCongestionDropped
		   Gauge32
      }

ethIfIntervalIndex OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The index of the Ethernet interface. 
        It may be ifIndex."
    ::= { ethIfIntervalEntry 1 }

ethIfIntervalNumber OBJECT-TYPE
    SYNTAX  Integer32 (1..96)
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
        "A number between 1 and 96, where 1 is the most
         recently completed 15 minute interval and 96 is
         the least recently completed 15 minutes interval
         (assuming that all 96 intervals exist)."
    ::= { ethIfIntervalEntry 2 }

ethIfIntervalStatus OBJECT-TYPE
	 SYNTAX OCTET STRING  (SIZE (4))
     MAX-ACCESS  read-only
     STATUS  current
     DESCRIPTION
      "The statuses of the current interval:
         0 - Valid.
         1 - redundantLinkSwitch - the link has been switched 
             by a redundancy mechanism.
         2 - discontinuity - module was partialy out.
         4 - notValid - module is out."
      ::= { ethIfIntervalEntry 3 }

ethIfIntervalInFrames OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of received frames, 
	  encountered by the Ethernet interface in one of the previous 
	  96, individual 15 minute, intervals."
      ::= { ethIfIntervalEntry 4 }

ethIfIntervalInOctets OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of received octets, 
	  encountered by the Ethernet interface in one of the previous 
	  96, individual 15 minute, intervals."
      ::= { ethIfIntervalEntry 5 }

ethIfIntervalAlignmentErrors OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of received frames, 
	  which are not complete (The result of dividing the number 
	  of bits by 8 is not an Integer), encountered by the Ethernet 
	  interface in one of the previous 96, individual 15 minute, 
	  intervals."
      ::= { ethIfIntervalEntry 6 }

ethIfIntervalFCSErrors OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of received frames 
	  that didn't pass the FCS test, encountered by the Ethernet 
	  interface in one of the previous 96, individual 15 minute, 
	  intervals."
      ::= { ethIfIntervalEntry 7 }

ethIfIntervalLengthError OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of received frames 
	  with length error, encountered by the Ethernet interface in 
	  one of the previous 96, individual 15 minute, intervals."
      ::= { ethIfIntervalEntry 8 }

ethIfIntervalOutFrames OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of transmitted frames, 
	  encountered by the Ethernet interface in one of the previous 
	  96, individual 15 minute, intervals."
      ::= { ethIfIntervalEntry 9 }

ethIfIntervalOutOctets OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of transmitted octets, 
	  encountered by the Ethernet interface in one of the previous 
	  96, individual 15 minute, intervals."
      ::= { ethIfIntervalEntry 10 }

ethIfIntervalSingleCollisionFrames OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of successfully
	  transmitted frames for which transmission was inhibited by
	  exactly one collision, encountered by the Ethernet 
	  interface in one of the previous 96, individual 15 minute, 
	  intervals."
      ::= { ethIfIntervalEntry 11 }

ethIfIntervalMultipleCollisionFrames OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of successfully
	  transmitted frames for which transmission was inhibited by
	  more than one collision, encountered by the Ethernet 
	  interface in one of the previous 96, individual 15 minute, 
	  intervals."
      ::= { ethIfIntervalEntry 12 }

ethIfIntervalDeferredTransmissions OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of transmitted frames 
	  for which the first transmission attempt was delayed due to a 
	  busy media, encountered by the Ethernet interface in one of 
	  the previous 96, individual 15 minute, intervals."
      ::= { ethIfIntervalEntry 13 }

ethIfIntervalLateCollisions OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of times that a 
	  collision was detected later than the first 64 bytes of the 
	  frame, encountered by the Ethernet interface in one of the 
	  previous 96, individual 15 minute, intervals."
      ::= { ethIfIntervalEntry 14 }

ethIfIntervalCarrierSenseErrors OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of times that the 
	  carrier sense condition was lost or never asserted when 
	  attempting to transmit a frame, encountered by the Ethernet 
	  interface in one of the previous 96, individual 15 minute, 
	  intervals."
      ::= { ethIfIntervalEntry 15 }

ethIfIntervalInputCongestionDropped OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of dropped frames 
	  due to a congestion, encountered by the Receive direction 
	  to the Ethernet interface in one of the previous 96, individual 
	  15 minute, intervals."
	  ::= { ethIfIntervalEntry 16 }

ethIfIntervalOutputCongestionDropped OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of dropped frames 
	  due to a congestion, encountered by the Transmit direction 
	  to the Ethernet interface in one of the previous 96, individual 
	  15 minute, intervals."
      ::= { ethIfIntervalEntry 17 }


ethPerformanceMode    OBJECT-TYPE
      SYNTAX  INTEGER
        {
          notApplicable  (1),
          countOK		 (2),
		  countFail		 (3)
     }
      MAX-ACCESS  read-write
      STATUS  current
      DESCRIPTION
      "This object indicates whether OK or Fail statistics will be counted."
      ::=  {ethIfPerformance 3}


ethIfPerfTable OBJECT-TYPE
      SYNTAX SEQUENCE OF EthIfPerfEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION
         "The Ethernet Performance table."
	  ::=  { ethIfPerformance 4}

ethIfPerfEntry OBJECT-TYPE
      SYNTAX EthIfPerfEntry
      MAX-ACCESS not-accessible
      STATUS current
	DESCRIPTION
         "An entry in the Ethernet Performance table."
	INDEX {ethIfIdx}
      ::= {ethIfPerfTable 1}

EthIfPerfEntry ::=
      SEQUENCE {
      ethIfPerfInOkFrames
      	   Gauge32,
      ethIfPerfOutOkFrames
      	   Gauge32,
	  ethIfPerfTotalCollisions
		   Gauge32
                  }


ethIfPerfInOkFrames OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of received OK frames, 
	  encountered by the Ethernet interface since ethPerformanceMode Set to countOK (2) 
	  or Reset Statistics was done."
      ::= { ethIfPerfEntry 1 }


ethIfPerfOutOkFrames OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of transmitted OK frames, 
	  encountered by the Ethernet interface since ethPerformanceMode Set to countOK (2) 
	  or Reset Statistics was done."
      ::= { ethIfPerfEntry 2 }


ethIfPerfTotalCollisions OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the total number of collisions 
	  of any type encountered by the Ethernet interface since 
	  ethPerformanceMode Set to countOK (2)  or Reset Statistics was done"
	  ::= { ethIfPerfEntry 3 }
-- 
-- file :v:\doc\rdv\mib\ver485\atm\atmCes.txt
-- 
-- 
-- File: v:\doc\rdv\mib\ver485\atm\atmCes.txt
-- Date:      17/01/02
-- By:        Ilana Schvetz

-- Last Update: 17-Jan-02 By Ilana Schvetz
-- 
-- AAL1 statistics. An addition to ATMF-CES (ces.mib) 
--
 
atmCes OBJECT IDENTIFIER  ::=  {radAtm 9}
 
atmCesPerformance      OBJECT IDENTIFIER ::= {atmCes 1 }

atmCesAal1CurrentTable OBJECT-TYPE
      SYNTAX  SEQUENCE OF AtmCesAal1CurrentEntry
      MAX-ACCESS   not-accessible
      STATUS  current
      DESCRIPTION
         "The AAL1 Current table."
      ::= { atmCesPerformance 1 }

atmCesAal1CurrentEntry OBJECT-TYPE
      SYNTAX  AtmCesAal1CurrentEntry
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
         "An entry in the AAL1 Current table."
      INDEX   { atmCesAal1CurrentIfIndex }
      ::= { atmCesAal1CurrentTable 1 }

AtmCesAal1CurrentEntry ::=
      SEQUENCE {
      atmCesAal1CurrentIfIndex
           Integer32,
      atmCesAal1CurrentSeqErrors
      	   Gauge32,
      atmCesAal1CurrentHdrErrors
           Gauge32,
      atmCesAal1CurrentPointerReframes
           Gauge32,
      atmCesAal1CurrentBufUnderflows
           Gauge32,
      atmCesAal1CurrentBufOverflows
           Gauge32
      }

atmCesAal1CurrentIfIndex OBJECT-TYPE
      SYNTAX      Integer32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
        "The index of the AAL1 interface. 
        It may be ifIndex."
    ::= { atmCesAal1CurrentEntry 1 }

atmCesAal1CurrentSeqErrors OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of Discarded 
        cells due to wrong sequence number, encountered 
        by an AAL1 interface in the current 15 minute interval."
      ::= { atmCesAal1CurrentEntry 2 }

atmCesAal1CurrentHdrErrors OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of Discarded 
        cells due to bad AAL1 header error (including correctable 
        and uncorrectable CRC, and bad parity), encountered 
        by an AAL1 interface in the current 15 minute interval."
      ::= { atmCesAal1CurrentEntry 3 }

atmCesAal1CurrentPointerReframes OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of events in 
	  which a SDT pointer isn't where it is expected to be, 
	  and must be reacquired, encountered by an AAL1 interface 
	  in the current 15 minute interval."
      ::= { atmCesAal1CurrentEntry 4 }

atmCesAal1CurrentBufUnderflows OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of buffer 
	  underflow events, encountered by an AAL1 interface 
	  in the current 15 minute interval."
      ::= { atmCesAal1CurrentEntry 5 }

atmCesAal1CurrentBufOverflows OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of buffer 
	  overflow events, encountered by an AAL1 interface 
	  in the current 15 minute interval."
      ::= { atmCesAal1CurrentEntry 6 }


--Interval Table


atmCesAal1IntervalTable OBJECT-TYPE
      SYNTAX  SEQUENCE OF AtmCesAal1IntervalEntry
      MAX-ACCESS   not-accessible
      STATUS  current
      DESCRIPTION
         "The AAL1 Interval table."
      ::= { atmCesPerformance 2 }

atmCesAal1IntervalEntry OBJECT-TYPE
      SYNTAX  AtmCesAal1IntervalEntry
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
         "An entry in the AAL1 Interval table."
              INDEX   { atmCesAal1IntervalIfIndex, atmCesAal1IntervalNumber }
              ::= { atmCesAal1IntervalTable 1 }

AtmCesAal1IntervalEntry ::=
      SEQUENCE {
      atmCesAal1IntervalIfIndex
           Integer32,
      atmCesAal1IntervalNumber
           Integer32,
      atmCesAal1IntervalSeqErrors
      	   Gauge32,
      atmCesAal1IntervalHdrErrors
           Gauge32,
      atmCesAal1IntervalPointerReframes
           Gauge32,
      atmCesAal1IntervalBufUnderflows
           Gauge32,
      atmCesAal1IntervalBufOverflows
           Gauge32
      }


atmCesAal1IntervalIfIndex OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The index of the AAL1 interface. 
        It may be ifIndex."
    ::= { atmCesAal1IntervalEntry 1 }

atmCesAal1IntervalNumber OBJECT-TYPE
    SYNTAX  Integer32 (1..96)
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
        "A number between 1 and 96, where 1 is the most
         recently completed 15 minute interval and 96 is
         the least recently completed 15 minutes interval
         (assuming that all 96 intervals exist)."
    ::= { atmCesAal1IntervalEntry 2 }

atmCesAal1IntervalSeqErrors OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of Discarded 
        cells due to wrong sequence number, encountered 
        by an AAL1 interface in one of the previous 96, 
        individual 15 minute, intervals."
      ::= { atmCesAal1IntervalEntry 3 }

atmCesAal1IntervalHdrErrors OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of Discarded 
        cells due to bad AAL1 header error (including correctable 
        and uncorrectable CRC, plus bad parity), encountered 
        by an AAL1 interface in one of the previous 96, 
        individual 15 minute, intervals."
      ::= { atmCesAal1IntervalEntry 4 }

atmCesAal1IntervalPointerReframes OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of events in 
	  which a SDT pointer isn't where it is expected to be, 
	  and must be reacquired, encountered by an AAL1 interface 
	  in one of the previous 96, individual 15 minute, 
	  intervals."
      ::= { atmCesAal1IntervalEntry 5 }

atmCesAal1IntervalBufUnderflows OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of buffer 
	  underflow events, encountered by an AAL1 interface 
	  in one of the previous 96, individual 15 minute, 
	  intervals."
      ::= { atmCesAal1IntervalEntry 6 }

atmCesAal1IntervalBufOverflows OBJECT-TYPE
      SYNTAX  Gauge32  
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
	  "The counter associated with the number of buffer 
	  overflow events, encountered by an AAL1 interface 
	  in one of the previous 96, individual 15 minute, 
	  intervals."
      ::= { atmCesAal1IntervalEntry 7 }


-- Extension for CES Configuration Table

atmCesConfiguration      OBJECT IDENTIFIER ::= {atmCes 2 }


 atmCesXConfTable OBJECT-TYPE
	SYNTAX SEQUENCE OF AtmCesXConfEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
    "This table is an extension of atmfCESConfTable table."
	::= { atmCesConfiguration 1 }

 atmCesXConfEntry OBJECT-TYPE
	SYNTAX AtmCesXConfEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
    "Conceptual row in atmfCESConfTable.
     A new row is created in this table upon each new CES VCC creation."
 AUGMENTS { atmfCESConfEntry }
	::= { atmCesXConfTable 1 }

 AtmCesXConfEntry ::= SEQUENCE {
	atmCesXConfCBRMode       INTEGER
 }

 atmCesXConfCBRMode     OBJECT-TYPE
    SYNTAX        INTEGER {
                      normal (2),
                      spaced (3)
                      }
    MAX-ACCESS    read-create
    STATUS        current
    DESCRIPTION
        "This parameter defines if to use Spaced or Normal CBR.  

         Normal - TD will be allocated from the policing range (described 
                  in ACE2002 NMS SRS). The PCR is expanded with a constant 
                  value of 30 cell/sec.
         Spaced - TD will be allocated from the spacing range (described 
                  in ACE2002 NMS SRS). The PCR and CDVT will be expanded 
                  as described for Normal, and the CES traffic including
                  the OAM will be spaced out at the TD's PCR.
                  This mode is used to prevent CDVT violation due to OAM 
                  cell insertion with the CES traffic."
    ::= { atmCesXConfEntry 1 }
-- 
-- file :v:\doc\rdv\mib\ver495\atm\atmRou~1.txt
-- 
--Version:   4.95
--
--First Version Date:   12-Aug-2002              
--By:        Shay Harari
--File:      atmRouter.txt
--
--Last update: 20-Oct-2002
--By: Ilana Schvetz 


radAtmRouter  OBJECT IDENTIFIER  ::= { radAtm 10 }


-- Extension of the ATM Logical IP Subnet Interface Mapping Table
-- ( ipoaLisIfMappingTable from RFC 2320 )

atmIpoaLisIfMappingXTable OBJECT-TYPE
	SYNTAX SEQUENCE OF AtmIpoaLisIfMappingXEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
    "This table is an extension of a table 
     from RFC 2320: ipoaLisIfMappingTable - 
     The ATM Logical IP Subnet Interface Mapping Table."
	::= { radAtmRouter 1 }

atmIpoaLisIfMappingXEntry OBJECT-TYPE
	SYNTAX AtmIpoaLisIfMappingXEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
    "Conceptual row in ipoaLisIfMappingTable."
	AUGMENTS { ipoaLisIfMappingEntry }
	::= { atmIpoaLisIfMappingXTable 1 }

AtmIpoaLisIfMappingXEntry ::= SEQUENCE {
	atmIpoaLisIfMappingType
		INTEGER,
	atmIpoaLisIfMappingIPAddress
		IpAddress	 
 }

atmIpoaLisIfMappingType OBJECT-TYPE
	SYNTAX  INTEGER {
       notApplicable(1),
	   static(2),
	   inAtmArp(3)
     }
    MAX-ACCESS  read-create
    STATUS  current
    DESCRIPTION
	"This object indicates the Mapping Type."
	::= { atmIpoaLisIfMappingXEntry 1 }

atmIpoaLisIfMappingIPAddress OBJECT-TYPE
    SYNTAX  IpAddress
	MAX-ACCESS  read-create
    STATUS  current
    DESCRIPTION
	"This parameter is applicable for 
	atmIpoaLisIfMappingTypeIP=static(2). 
	This parameter is the IP Address assigned 
	by the user when applicable."
	::= { atmIpoaLisIfMappingXEntry 2 }


radAtmRtrInAtmArpInterval OBJECT-TYPE   
	SYNTAX  Integer32 
	MAX-ACCESS  read-write    
	STATUS  current
	DESCRIPTION
	"The time interval (in seconds) between sending of
	 two InATMARP requests."
	::= { radAtmRouter 2 }

radAtmRtrInAtmArpAgingTime OBJECT-TYPE   
	SYNTAX  Integer32 
	MAX-ACCESS  read-write    
	STATUS  current
	DESCRIPTION
	"The time (in seconds) that passes until an 
	 entry is deleted, unless this entry
	 was previously updated by a new inATMARP 
	 request or response.
	 
	 This variable value should be greater than 
	 the value of radAtmRtrInAtmArpInterval,
	 so that the entry won't be deleted before
	 an InATMARP request was sent."
	::= { radAtmRouter 3 }



-- clksrc.txt is the clock source table that was taken from dacs.txt for ace2002 use

END