QTECH-VPLS-GENERIC-MIB DEFINITIONS ::= BEGIN
      IMPORTS
      NOTIFICATION-TYPE, MODULE-IDENTITY, OBJECT-TYPE,
      Unsigned32, Counter32, transmission
         FROM SNMPv2-SMI                    -- RFC2578

      MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
         FROM SNMPv2-CONF                   -- RFC2580

      TruthValue, RowStatus, StorageType
         FROM SNMPv2-TC                     -- RFC2579

      SnmpAdminString
         FROM SNMP-FRAMEWORK-MIB            -- RFC3411

      PwIndexType
         FROM PW-TC-STD-MIB

--  We need to add this for vpls instance
			InterfaceIndexOrZero
        FROM IF-MIB                        -- [RFC2863]

      VPNIdOrZero
         FROM VPN-TC-STD-MIB                -- RFC4265

      qtechMgmt
         FROM QTECH-SMI
      ;

    -- Vpls BGP Autodiscovery specific Textual Convention
    QtechVplsBgpRouteDistinguisher ::= TEXTUAL-CONVENTION
      STATUS        current
      DESCRIPTION
          "Syntax for a route distinguisher. For a complete
           definition of a route distinguisher, see [RFC4364].
           For more details on use of a route distinguisher
           for a VPLS service, see [RFC4761]"
      REFERENCE
          "[RFC4364]"
      SYNTAX  OCTET STRING(SIZE (0..256))

    QtechVplsBgpRouteTarget ::= TEXTUAL-CONVENTION
      STATUS        current
      DESCRIPTION
          "Syntax for a route target. For a complete
           definition of a route target, see [RFC4364]."
      REFERENCE
          "[RFC4364]"
      SYNTAX  OCTET STRING(SIZE (0..256))

    QtechVplsBgpRouteTargetType ::= TEXTUAL-CONVENTION
      STATUS        current
      DESCRIPTION
       "Used to define the type of a route target usage.
        Route targets can be specified to be imported,
        exported, or both.  For a complete definition of a
        route target, see [RFC4364]."
      REFERENCE
        "[RFC4364]"
      SYNTAX INTEGER { import(1), export(2), both(3) }

   qtechvplsGenericDraft01MIB MODULE-IDENTITY
      LAST-UPDATED "201004281200Z"  -- 28 April 2010 12:00:00 GMT
      ORGANIZATION "Qtech Networks Co.,Ltd."
      CONTACT-INFO
                "
                Tel: 4008-111-000

                E-mail: service@qtech.com.cn"

      DESCRIPTION
          "Copyright (C) Qtech Networks.
           This MIB module contains generic managed object definitions
           for Virtual Private LAN Services as in [RFC4762] and
           [RFC4761]

           This MIB module enables the use of any underlying PseudoWire
           network."
      -- Revision history.
      REVISION
          "201004281200Z"  -- 28 April 2010 12:00:00 GMT
      DESCRIPTION
          "Changes from previous version:
           1) Moved LDP Specific information to VPLS-LDP-MIB
           2) Created the qtechvplsStatusTable to store status information.
          "
      REVISION
          "201006041200Z"  -- 4 June 2010 12:00:00 GMT


      DESCRIPTION "Initial version"
           ::= { qtechMgmt 77 }

   -- Top-level components of this MIB.

   -- Notifications
   qtechvplsNotifications OBJECT IDENTIFIER
                                 ::= { qtechvplsGenericDraft01MIB 0 }
   -- Tables, Scalars
   qtechvplsObjects       OBJECT IDENTIFIER
                                 ::= { qtechvplsGenericDraft01MIB 1 }
   -- Conformance
   qtechvplsConformance   OBJECT IDENTIFIER
                                 ::= { qtechvplsGenericDraft01MIB 2 }

   -- PW Virtual Connection Table

   qtechvplsConfigIndexNext OBJECT-TYPE
      SYNTAX            Unsigned32
      MAX-ACCESS        read-only
      STATUS            current
      DESCRIPTION
          "This object contains an appropriate value to be used
           for qtechvplsConfigIndex when creating entries in the
           qtechvplsConfigTable. The value 0 indicates that no
           unassigned entries are available.  To obtain the
           value of qtechvplsConfigIndex for a new entry in the
           qtechvplsConfigTable, the manager issues a management
           protocol retrieval operation to obtain the current
           value of qtechvplsConfigIndex.  After each retrieval
           operation, the agent should modify the value to
           reflect the next unassigned index.  After a manager
           retrieves a value the agent will determine through
           its local policy when this index value will be made
           available for reuse."
      ::= { qtechvplsObjects 1 }

      qtechvplsConfigTable OBJECT-TYPE
          SYNTAX          SEQUENCE OF QtechVplsConfigEntry
          MAX-ACCESS      not-accessible
          STATUS          current
          DESCRIPTION
               "This table specifies information for configuring
                and monitoring Virtual Private Lan Services(VPLS).
                "
          ::= { qtechvplsObjects 2 }

      qtechvplsConfigEntry OBJECT-TYPE
          SYNTAX          QtechVplsConfigEntry
          MAX-ACCESS      not-accessible
          STATUS          current
          DESCRIPTION
           "A row in this table represents a Virtual Private Lan
            Service(VPLS) in a packet network. It is indexed by
            qtechvplsConfigIndex, which uniquely identifies a single VPLS.

            A row is created by the operator or by the agent if a
            VPLS service is created by non-SNMP application or
            due to autodiscovery process.

            None of the read-create objects values can be
            changed when qtechvplsConfigRowStatus is in the active(1)
            state. Changes are allowed when the qtechvplsConfigRowStatus
            is in notInService(2) or notReady(3) states only.
            If the operator need to change one of the values
            for an active row the qtechvplsConfigRowStatus should be
            first changed to notInService(2), the objects may
            be changed now, and later to active(1) in order to
            re-initiate the signaling process with the new
            values in effect.
            "
          INDEX           { qtechvplsConfigIndex }
          ::= { qtechvplsConfigTable 1 }

     QtechVplsConfigEntry ::=
        SEQUENCE {
         qtechvplsConfigIndex                                Unsigned32,
         qtechvplsConfigName                                 SnmpAdminString,
         qtechvplsConfigDescr                                SnmpAdminString,
         qtechvplsConfigAdminStatus                          INTEGER,
         qtechvplsConfigMacLearning                          TruthValue,
         qtechvplsConfigDiscardUnknownDest                   TruthValue,
         qtechvplsConfigMacAging                             TruthValue,
         qtechvplsConfigFwdFullHighWatermark                 Unsigned32,
         qtechvplsConfigFwdFullLowWatermark                  Unsigned32,
         qtechvplsConfigRowStatus                            RowStatus,
         qtechvplsConfigMtu                                  Unsigned32,
         qtechvplsConfigVpnId                                VPNIdOrZero,
         qtechvplsConfigServiceType                          INTEGER,
         qtechvplsConfigServiceSignal                        INTEGER
          }

      qtechvplsConfigIndex  OBJECT-TYPE
          SYNTAX          Unsigned32  (1..2147483647)
          MAX-ACCESS      not-accessible
          STATUS          current
          DESCRIPTION
               "Unique index for the conceptual row identifying
                a VPLS service."
          ::= { qtechvplsConfigEntry 1 }

      qtechvplsConfigName  OBJECT-TYPE
          SYNTAX          SnmpAdminString
          MAX-ACCESS      read-create
          STATUS          current
          DESCRIPTION
               "A textual name of the VPLS.
                If there is no local name, or this object is
                otherwise not applicable, then this object MUST
                contain a zero-length octet string."
          DEFVAL           { "" }
          ::= { qtechvplsConfigEntry 2 }

      qtechvplsConfigDescr  OBJECT-TYPE
          SYNTAX          SnmpAdminString
          MAX-ACCESS      read-create
          STATUS          current
          DESCRIPTION
               "A textual string containing information about the
               VPLS service. If there is no information for this VPLS
               service, then this object MUST contain a zero-length
               octet string."
          DEFVAL           { "" }
          ::= { qtechvplsConfigEntry 3 }

      qtechvplsConfigAdminStatus OBJECT-TYPE
          SYNTAX          INTEGER {
                              up(1),
                              down(2),
                              testing(3)   -- in some test mode

                          }
          MAX-ACCESS      read-only
          STATUS          current
          DESCRIPTION
               "The desired administrative state of the VPLS
                service. If the administrative status of the
                Vpls service is changed to enable then this
                service is able to utilize the pseudo wire to
                perform the tasks of a VPLS service.
                The testing(3) state indicates that no operational
                packets can be passed. "
          DEFVAL           { up }
          ::= { qtechvplsConfigEntry 4 }

      qtechvplsConfigMacLearning OBJECT-TYPE
          SYNTAX          TruthValue
          MAX-ACCESS      read-create
          STATUS          current
          DESCRIPTION
               "This object specifies if MAC Learning is enabled
                in this service. If this object is true then Mac
                Learning is enabled. If false, then Mac Learning is
                disabled."
          DEFVAL          { true }
          ::= { qtechvplsConfigEntry 5 }

      qtechvplsConfigDiscardUnknownDest OBJECT-TYPE
          SYNTAX          TruthValue
          MAX-ACCESS      read-create
          STATUS          current
          DESCRIPTION
               "If the value of this object is 'true', then frames
                received with an unknown destination MAC are discarded
                in this VPLS. If 'false', then the packets are
                processed."
          DEFVAL          { false }
          ::= { qtechvplsConfigEntry 6 }

      qtechvplsConfigMacAging OBJECT-TYPE
          SYNTAX          TruthValue
          MAX-ACCESS      read-only
          STATUS          current
          DESCRIPTION
               "If the value of this object is 'true'
                then the MAC aging process is enabled in
                this VPLS. If 'false', then the MAC aging process
                is disabled"
          DEFVAL          { true }
          ::= { qtechvplsConfigEntry 7 }

      qtechvplsConfigFwdFullHighWatermark OBJECT-TYPE
          SYNTAX          Unsigned32 (0..100)
          UNITS           "percentage"
          MAX-ACCESS      read-create
          STATUS          current
          DESCRIPTION
               "This object specifies the utilization of the
                forwarding database for this VPLS instance at
                which the qtechvplsFwdFullAlarmRaised notification
                will be sent."
          DEFVAL          { 100 }
          ::= { qtechvplsConfigEntry 8 }

      qtechvplsConfigFwdFullLowWatermark OBJECT-TYPE
          SYNTAX          Unsigned32 (0..100)
          UNITS           "percentage"
          MAX-ACCESS      read-create
          STATUS          current
          DESCRIPTION
               "This object specifies the utilization of the
                forwarding database for this VPLS instance
                at which the qtechvplsFwdFullAlarmCleared
                notification will be sent."
          DEFVAL          { 80 }
          ::= { qtechvplsConfigEntry 9 }

      qtechvplsConfigRowStatus OBJECT-TYPE
          SYNTAX          RowStatus
          MAX-ACCESS      read-create
          STATUS          current
          DESCRIPTION
               "For creating, modifying, and deleting this row.
                None of the read-create objects in the
                conceptual rows may be changed when this
                object is in the active(1) state."
          ::= { qtechvplsConfigEntry 10 }

      qtechvplsConfigMtu OBJECT-TYPE
          SYNTAX          Unsigned32 (46..1530)
          MAX-ACCESS      read-create
          STATUS          current
          DESCRIPTION
               "The value of this object specifies the MTU of this
                vpls instance."
          DEFVAL          { 1500 }
          ::= { qtechvplsConfigEntry 11 }

      qtechvplsConfigVpnId OBJECT-TYPE
          SYNTAX          VPNIdOrZero
          MAX-ACCESS      read-create
          STATUS          current
          DESCRIPTION
               "This objects indicates the IEEE 802-1990
                VPN ID of the associated VPLS service."
-- Ed note: Should we import the VPNIdOrZero TC or
--              define a new TC?
          ::= { qtechvplsConfigEntry 12 }

      qtechvplsConfigServiceType OBJECT-TYPE
          SYNTAX          INTEGER {
                           vlan     (1),
                           ethernet (2)
                          }
          MAX-ACCESS      read-create
          STATUS          current
          DESCRIPTION
               "The value of this object specifies the type of
                service emulated by this vpls instance. Invalid for RFC 4762"
          DEFVAL          { vlan }
          ::= { qtechvplsConfigEntry 13 }

      qtechvplsConfigServiceSignal   OBJECT-TYPE
           SYNTAX          INTEGER {
                                   manual        (1),
                                   autodiscovery (2)
                           }
           MAX-ACCESS      read-create
           STATUS          current
           DESCRIPTION
                "The value of this object indicates
                 vpls is created with LDP or BGP signalling.

                 The value of this object must be
                 specifed when the row is created and cannot
                 be changed while the row status is active(1)"
          ::= { qtechvplsConfigEntry 14}


-- VPLS Status table

      qtechvplsStatusTable OBJECT-TYPE
          SYNTAX          SEQUENCE OF QtechVplsStatusEntry
          MAX-ACCESS      not-accessible
          STATUS          current
          DESCRIPTION
                "This table provides information for monitoring
                Virtual Private Lan Services(VPLS).
                "
          ::= { qtechvplsObjects 3 }

      qtechvplsStatusEntry OBJECT-TYPE
          SYNTAX          QtechVplsStatusEntry
          MAX-ACCESS      not-accessible
          STATUS          current

          DESCRIPTION
           "A row in this table represents a Virtual Private Lan
            Service(VPLS) in a packet network. It is indexed by
            qtechvplsConfigIndex, which uniquely identifies a single VPLS.

            A row in this table is automatically created by the agent
            when a VPLS service is configured.
            "
          INDEX           { qtechvplsConfigIndex }
          ::= { qtechvplsStatusTable 1 }

     QtechVplsStatusEntry ::=
        SEQUENCE {
         qtechvplsStatusOperStatus                        INTEGER,
         qtechvplsStatusPeerCount                         Counter32
          }

      qtechvplsStatusOperStatus OBJECT-TYPE
          SYNTAX          INTEGER {
                              up(1),
                              down(2)
                          }
          MAX-ACCESS      read-only
          STATUS          current
          DESCRIPTION
               "The current operational state of this VPLS Service."
          ::= { qtechvplsStatusEntry 1 }

      qtechvplsStatusPeerCount OBJECT-TYPE
          SYNTAX          Counter32
          MAX-ACCESS      read-only
          STATUS          current
          DESCRIPTION
               "This objects specifies the number of peers
                present in this vpls instance."
          ::= { qtechvplsStatusEntry 2 }


      -- VPLS PW Binding Table

      qtechvplsPwBindTable OBJECT-TYPE
          SYNTAX          SEQUENCE OF QtechVplsPwBindEntry
          MAX-ACCESS      not-accessible
          STATUS          current
          DESCRIPTION
               "This table provides an association between a
                VPLS service and the corresponding Pseudo
                Wires. A service can have more than one Pseudo
                Wire association. Pseudo Wires are defined in
                the pwTable"
          ::= { qtechvplsObjects 4 }

      qtechvplsPwBindEntry OBJECT-TYPE
          SYNTAX          QtechVplsPwBindEntry
          MAX-ACCESS      not-accessible
          STATUS          current
          DESCRIPTION
               "Each row represents an association between a
                VPLS instance and one or more Pseudo Wires
                defined in the pwTable. Each index is unique
                in describing an entry in this table. However
                both indexes are required to define the one
                to many association of service to
                pseudowire."
          INDEX  { qtechvplsConfigIndex,qtechvplsPwBindIndex }
          ::= { qtechvplsPwBindTable 1 }

      QtechVplsPwBindEntry ::=
          SEQUENCE {
							qtechvplsPwBindIndex            Unsigned32,
              qtechvplsPwBindConfigType       INTEGER,
              qtechvplsPwBindType             INTEGER
          }

     qtechvplsPwBindIndex  OBJECT-TYPE
          SYNTAX          Unsigned32
          MAX-ACCESS      not-accessible
          STATUS          current
          DESCRIPTION
               "Unique index for PW bind in vpls instance."
          ::= { qtechvplsPwBindEntry 1 }

-- qtechvplsPwBindConfigType depends on vpls implementation type.
      qtechvplsPwBindConfigType   OBJECT-TYPE
           SYNTAX          INTEGER {
                                   manual        (1),
                                   autodiscovery (2)
                           }
           MAX-ACCESS      read-only
           STATUS          current
           DESCRIPTION
                "The value of this object indicates
                 whether the Pseudo Wire binding was created
                 manually or via autodiscovery.

                 The value of this object must be
                 specifed when the row is created and cannot
                 be changed while the row status is active(1)"
          ::= { qtechvplsPwBindEntry 2}

--  This is hub pw or spoke pw
      qtechvplsPwBindType   OBJECT-TYPE
           SYNTAX          INTEGER {
                                   mesh  (1),
                                   spoke (2)
                           }
           MAX-ACCESS      read-only
           STATUS          current
           DESCRIPTION
                "The value of this object indicates
                 whether the Pseudo Wire binding is of
                 type mesh or spoke.

                 The value of this object must be
                 specifed when the row is created and cannot
                 be changed while the row status is active(1)"
          ::= { qtechvplsPwBindEntry 3 }


-- qtechvplsBgpADConfigTable

      qtechvplsBgpADConfigTable OBJECT-TYPE
            SYNTAX          SEQUENCE OF QtechVplsBgpADConfigEntry
            MAX-ACCESS      not-accessible
            STATUS          current
            DESCRIPTION
            "This table specifies information for configuring
             BGP Auto-discovery parameters for a given Vpls service.
            "
            ::= { qtechvplsObjects 5 }

      qtechvplsBgpADConfigEntry OBJECT-TYPE
            SYNTAX          QtechVplsBgpADConfigEntry
            MAX-ACCESS      not-accessible
            STATUS          current
            DESCRIPTION
            "A row in this table represents BGP based autodiscovery
             is in use for this instance of Vpls.
             A row in this table is indexed by qtechvplsConfigIndex, which
             uniquely identifies a single VPLS.
             None of the read-create objects can be changed when
             vplsBGPADConfigRowStatus is in active(1) state. Changes
             are allowed when the vplsBGPADConfigRowStatus is in
             notInService(2) or notReady(3) states only.
             If the operator need to change one of the values
             for an active row the qtechvplsConfigRowStatus should be
             first changed to notInService(2), the objects may
             be changed now, and later to active(1) in order to
             re-initiate the signaling process with the new
             values in effect.
            "
            INDEX      { qtechvplsConfigIndex }
            ::= { qtechvplsBgpADConfigTable 1 }

      QtechVplsBgpADConfigEntry ::=
         SEQUENCE {
          qtechvplsBgpADConfigRouteDistinguisher   QtechVplsBgpRouteDistinguisher,
          qtechvplsBgpADConfigRowStatus            RowStatus
         }

      qtechvplsBgpADConfigRouteDistinguisher OBJECT-TYPE
            SYNTAX          QtechVplsBgpRouteDistinguisher
            MAX-ACCESS      read-create
            STATUS          current
            DESCRIPTION
            " The route distinguisher for this VPLS. See [RFC4364]
            for a complete definition of a route distinguisher.
            for more details on use of a route distinguisher
            for a VPLS service, see [RFC4761]
            "
            ::= { qtechvplsBgpADConfigEntry 1 }

      qtechvplsBgpADConfigRowStatus OBJECT-TYPE
            SYNTAX          RowStatus
            MAX-ACCESS      read-create
            STATUS          current
            DESCRIPTION
            " For creating, modifying, and deleting this row.
            None of the read-create objects in the
            conceptual rows may be changed when this
            object is in the active(1) state.
            "
            ::= { qtechvplsBgpADConfigEntry 2 }


    -- qtechvplsBgpRteTargetTable

      qtechvplsBgpRteTargetTable   OBJECT-TYPE
            SYNTAX          SEQUENCE OF QtechVplsBgpRteTargetEntry
            MAX-ACCESS      not-accessible
            STATUS          current
            DESCRIPTION
            " This table specifies the list of Route Targets
              imported or exported by BGP during auto-discovery of VPLS.
            "
            ::= { qtechvplsObjects 6 }

      qtechvplsBgpRteTargetEntry   OBJECT-TYPE
            SYNTAX          QtechVplsBgpRteTargetEntry
            MAX-ACCESS      not-accessible
            STATUS          current
            DESCRIPTION
              "An entry in this table specifies the value of the
               Route Target being used by BGP. Depending on the value
               of vplsBgpRteTargetType an RT might be exported or
               imported or both. Every VPLS which
              uses auto-discovery for finding peer nodes can import and
              export multiple Route Targets. This representation allows
              support for hierarchical VPLS.
            "
            INDEX     { qtechvplsConfigIndex, qtechvplsBgpRteTargetIndex }
            ::= { qtechvplsBgpRteTargetTable 1 }

      QtechVplsBgpRteTargetEntry ::=
         SEQUENCE {
          qtechvplsBgpRteTargetIndex          Unsigned32,
          qtechvplsBgpRteTargetRTType         QtechVplsBgpRouteTargetType,
          qtechvplsBgpRteTargetRT             QtechVplsBgpRouteTarget,
          qtechvplsBgpRteTargetRTRowStatus    RowStatus
         }

      qtechvplsBgpRteTargetIndex   OBJECT-TYPE
            SYNTAX          Unsigned32
            MAX-ACCESS      not-accessible
            STATUS          current
            DESCRIPTION
            "This index along with qtechvplsConfigIndex,identifies one entry
             in the qtechvplsBgpRteTargetTable. By keeping qtechvplsConfigIndex
             constant and using new value of qtechvplsBgpRteTargetIndex user
              can configure multiple Route Targets for the same Vpls.
            "
            ::= {qtechvplsBgpRteTargetEntry  1 }

      qtechvplsBgpRteTargetRTType  OBJECT-TYPE
            SYNTAX          QtechVplsBgpRouteTargetType
            MAX-ACCESS      read-create
            STATUS          current
            DESCRIPTION
            " Used to define the type of a route target usage.
              Route targets can be specified to be imported,
              exported, or both.  For a complete definition of a
              route target, see [RFC4364]."
            ::= { qtechvplsBgpRteTargetEntry 2 }

      qtechvplsBgpRteTargetRT     OBJECT-TYPE
            SYNTAX          QtechVplsBgpRouteTarget
            MAX-ACCESS      read-create
            STATUS          current
            DESCRIPTION
            " The route target associated with the VPLS service.
              For more details on use of route targets
              for a VPLS service, see [RFC4761] "
            ::= { qtechvplsBgpRteTargetEntry 3 }

      qtechvplsBgpRteTargetRTRowStatus     OBJECT-TYPE
            SYNTAX          RowStatus
            MAX-ACCESS      read-create
            STATUS          current
            DESCRIPTION
            "This variable is used to create, modify, and/or
             delete a row in this table.  When a row in this
             table is in active(1) state, no objects in that row
             can be modified "
            ::= { qtechvplsBgpRteTargetEntry 4 }

--  qtechvplsIfBindTable

          qtechvplsIfBindTable OBJECT-TYPE
          SYNTAX          SEQUENCE OF QtechVplsIfBindEntry
          MAX-ACCESS      not-accessible
          STATUS          current
          DESCRIPTION
               "This table provides an association between a
                VPLS service and interface. A service can bind
                more than one interface. "
          ::= { qtechvplsObjects 7 }

      qtechVplsIfBindEntry OBJECT-TYPE
          SYNTAX          QtechVplsIfBindEntry
          MAX-ACCESS      not-accessible
          STATUS          current
          DESCRIPTION
               "Each row represents an association between a
                VPLS instance and one or more interface. Each
                index is unique in describing an entry in this table. "
          INDEX  { qtechvplsConfigIndex,qtechvplsIfBindIndex}
          ::= { qtechvplsIfBindTable 1 }

      QtechVplsIfBindEntry ::=
          SEQUENCE {
			        qtechvplsIfBindIndex           InterfaceIndexOrZero,
							qtechvplsSiteId                Unsigned32,
							qtechvplsIfRowStatus           RowStatus
          }

     qtechvplsIfBindIndex  OBJECT-TYPE
          SYNTAX          InterfaceIndexOrZero
          MAX-ACCESS      read-create
          STATUS          current
          DESCRIPTION
               "Interface index for vpls instance.
               "
          ::= { qtechVplsIfBindEntry 1 }

     qtechvplsSiteId  OBJECT-TYPE
          SYNTAX          Unsigned32
          MAX-ACCESS      read-create
          STATUS          current
          DESCRIPTION
               "VE id associated with the VPLS service.
               "
          ::= { qtechVplsIfBindEntry 2 }

		qtechvplsIfRowStatus OBJECT-TYPE
        SYNTAX        RowStatus
        MAX-ACCESS    read-create
        STATUS        current
        DESCRIPTION
            "This variable is used to create, modify, and/or
             delete a row in this table.  When a row in this
             table is in active(1) state, no objects in that row
             can be modified except vplsBgpSiteRowStatus."
        ::= { qtechVplsIfBindEntry 3 }


      -- VPLS Service Notifications

      qtechvplsFwdFullAlarmRaised NOTIFICATION-TYPE
          OBJECTS {
              qtechvplsConfigVpnId,
              qtechvplsConfigFwdFullHighWatermark,
              qtechvplsConfigFwdFullLowWatermark
          }
          STATUS          current
          DESCRIPTION
               "The qtechvplsFwdFullAlarmRaised notification is
                generated when the utilization of the Forwarding
                database is above the value specified by
                qtechvplsConfigFwdFullHighWatermark."
          ::= { qtechvplsNotifications 1 }

      qtechvplsFwdFullAlarmCleared NOTIFICATION-TYPE
          OBJECTS {
              qtechvplsConfigVpnId,
              qtechvplsConfigFwdFullHighWatermark,
              qtechvplsConfigFwdFullLowWatermark
          }
          STATUS          current
          DESCRIPTION
               "The qtechvplsFwdFullAlarmCleared notification is
                generated when the utilization of the Forwarding
                database is below the value specified by
                qtechvplsConfigFwdFullLowWatermark."
          ::= { qtechvplsNotifications 2 }

   -- Compliance requirement for read-only implementations.

   qtechvplsCompliances
     OBJECT IDENTIFIER ::= { qtechvplsConformance 1 }
   qtechvplsModuleFullCompliance MODULE-COMPLIANCE
      STATUS current
      DESCRIPTION
           "Compliance requirement for implementations that
            provide full support for VPLS-GENERIC-DRAFT-01-MIB.
            Such devices can then be monitored and configured using
            this MIB module."
      MODULE -- this module

          MANDATORY-GROUPS {
               qtechvplsGroup,
               qtechvplsPwBindGroup,
               qtechvplsNotificationGroup
           }

      ::= { qtechvplsCompliances 1 }


   qtechvplsModuleReadOnlyCompliance MODULE-COMPLIANCE
      STATUS current
      DESCRIPTION
           "Compliance requirement for implementations that only
            provide read-only support for VPLS-GENERIC-DRAFT-01-MIB.
            Such devices can then be monitored but cannot be
            configured using this MIB modules."

      MODULE -- this module

          MANDATORY-GROUPS {
               qtechvplsGroup,
               qtechvplsPwBindGroup,
               qtechvplsNotificationGroup
           }

           OBJECT          qtechvplsConfigName
           MIN-ACCESS      read-only
           DESCRIPTION
               "Write access is not required."


           OBJECT          qtechvplsConfigDescr
           MIN-ACCESS      read-only
           DESCRIPTION
               "Write access is not required."

           OBJECT          qtechvplsConfigAdminStatus
           MIN-ACCESS      read-only
           DESCRIPTION
               "Write access is not required."

           OBJECT          qtechvplsConfigMacLearning
           MIN-ACCESS      read-only
           DESCRIPTION
               "Write access is not required."

           OBJECT          qtechvplsConfigDiscardUnknownDest
           MIN-ACCESS      read-only
           DESCRIPTION
               "Write access is not required."

           OBJECT          qtechvplsConfigMacAging
           MIN-ACCESS      read-only
           DESCRIPTION
               "Write access is not required."

           OBJECT          qtechvplsConfigFwdFullHighWatermark
           MIN-ACCESS      read-only
           DESCRIPTION

               "Write access is not required."

           OBJECT          qtechvplsConfigFwdFullLowWatermark
           MIN-ACCESS      read-only
           DESCRIPTION
               "Write access is not required."

           OBJECT          qtechvplsConfigRowStatus
           MIN-ACCESS      read-only
           DESCRIPTION
               "Write access is not required."

           OBJECT          qtechvplsConfigMtu
           MIN-ACCESS      read-only
           DESCRIPTION
               "Write access is not required."

           OBJECT          qtechvplsConfigServiceType
           MIN-ACCESS      read-only
           DESCRIPTION
               "Write access is not required."

           OBJECT          qtechvplsPwBindConfigType
           MIN-ACCESS      read-only
           DESCRIPTION
               "Write access is not required."
           OBJECT          qtechvplsPwBindType
           MIN-ACCESS      read-only
           DESCRIPTION
               "Write access is not required."

      ::= { qtechvplsCompliances 2 }

-- Units of conformance.

      qtechvplsGroups
        OBJECT IDENTIFIER ::= { qtechvplsConformance 2 }


      qtechvplsGroup OBJECT-GROUP
          OBJECTS {
              qtechvplsConfigName,
              qtechvplsConfigDescr,
              qtechvplsConfigAdminStatus,
              qtechvplsConfigMacLearning,
              qtechvplsConfigDiscardUnknownDest,
              qtechvplsConfigMacAging,
              qtechvplsConfigVpnId,
              qtechvplsConfigFwdFullHighWatermark,
              qtechvplsConfigFwdFullLowWatermark,
              qtechvplsConfigRowStatus,
              qtechvplsConfigIndexNext,
              qtechvplsConfigMtu,
              qtechvplsConfigServiceType,
              qtechvplsStatusOperStatus,
              qtechvplsStatusPeerCount
          }
          STATUS          current
          DESCRIPTION
               "The group of objects supporting
                management of L2VPN VPLS services"
          ::= { qtechvplsGroups 1 }

      qtechvplsPwBindGroup OBJECT-GROUP
          OBJECTS {
              qtechvplsPwBindConfigType,
              qtechvplsPwBindType
          }
          STATUS          current
          DESCRIPTION
               "The group of objects supporting
                management of
                Pseudo Wire (PW) Binding to VPLS."
          ::= { qtechvplsGroups 2 }

      qtechvplsNotificationGroup NOTIFICATION-GROUP
          NOTIFICATIONS   {
              qtechvplsFwdFullAlarmRaised,
              qtechvplsFwdFullAlarmCleared
          }
          STATUS          current
          DESCRIPTION
               "The group of notifications supporting
                the  Notifications generated for
                VPLS Services"
          ::= { qtechvplsGroups 3 }
END