-- == Copyright (C) 2003 Paradyne Corporation.                  ==
-- ===============================================================

PDN-HDSL2-SHDSL-LINE-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, 
    Unsigned32, Counter32, Integer32
        FROM SNMPv2-SMI
    OBJECT-GROUP, NOTIFICATION-GROUP, MODULE-COMPLIANCE
        FROM SNMPv2-CONF
    TEXTUAL-CONVENTION
        FROM SNMPv2-TC
    SnmpAdminString
        FROM SNMP-FRAMEWORK-MIB
    ifIndex
        FROM IF-MIB
    PerfCurrentCount, PerfIntervalCount
        FROM PerfHist-TC-MIB
    Hdsl2ShdslPerfTimeElapsed, Hdsl2ShdslPerfCurrDayCount, 
    Hdsl2Shdsl1DayIntervalCount, hdsl2ShdslInvIndex, hdsl2ShdslEndpointSide, 
    hdsl2ShdslEndpointThreshLoopAttenuation,
    hdsl2ShdslEndpointThreshSNRMargin, hdsl2ShdslEndpointThreshES,
    hdsl2ShdslEndpointThreshSES, hdsl2ShdslEndpointThreshCRCanomalies,
    hdsl2ShdslEndpointThreshLOSWS, hdsl2ShdslEndpointThreshUAS, hdsl2ShdslSpanConfProfileName
        FROM HDSL2-SHDSL-LINE-MIB
    pdn-interfaces
        FROM PDN-HEADER-MIB;
        
pdnHdsl2ShdslLineMIB MODULE-IDENTITY
    LAST-UPDATED "200501280000Z"  -- January 28, 2005
    ORGANIZATION "Paradyne Networks
                  MIB Working Group
                  Other information about group editing the MIB"
    CONTACT-INFO "Paradyne Networks, Inc.
                  8545 126th Avenue North
                  Largo, FL 33733
                  www.paradyne.com
        
                  General Comments to: mibwg_team@paradyne.com

                  Editor
                      Clay Sikes"

    DESCRIPTION
        "The primary purpose of this MIB is to allow support of G.shdsl.bis based 
         on the ITU Temporary Document, DC-R15, April 2003, until such a time
         as the `standard' MIB, HDSL2-SHDSL-LINE-MIB, RFC 3276, May 2002 is
         updated to support G.shdsl.bis. In addition to providing support for
         G.shdsl.bis, this MIB may support SHDSL objects that are unique to the
         enterprise.

         Decisions as far as how this MIB is supported with respect to the 
         `standard' MIB will be made in an individual basis by those involved 
         with specific projects; those decisions are not dictated here.

         The following documents should be referenced with respect to this MIB:
         [G.991.2]     ITU-T G991.2 `Single-pair high-speed digital subscriber 
                       line (SHDSL) transceivers,' December 2003.
         [DC-R15]      ITU Study Group 15 Temporary Document `G.shdsl.bis: Draft
                       Text`, April 2003.
         [RFC 3276]    Ray, B., Abbi, R. `HDSL2-SHDSL-LINE-MIB', May 2002.

         =====================================================================
         ==                                                                 ==
         ==            Copyright (C) 2004 Paradyne Corporation.             ==
         ==                                                                 ==
         ====================================================================="

    REVISION "200501280000Z"  -- January 28, 2005
    DESCRIPTION "Added pdnHdsl2ShdslExtendedRateMode object since the
                 hardware implementation may require a different configuration
                 to support higher rates such as the 5696 kbits per second 
                 rate specified in 992.1, Annex F."

    REVISION "200404270000Z"  -- April 27, 2004
    DESCRIPTION "Make the index to pdnHdsl2ShdslSpanConfProfileExtTable IMPLIED 
                 to match with the RFC."

    REVISION "200404210000Z"  -- April 21, 2004
    DESCRIPTION "Changed the pdnHdsl2ShdslSpanStatusExtTable and the
                 pdnHdsl2ShdslSpanConfProfileExtTable from augments to be
                 indexed. Some SNMP agents do a read-modify-write on a table
                 row. As a result, the instrumentation code may not be able to 
                 determine which object the manager actually wants to set. For 
                 example, consider the case where a manager wants to set the 
                 wire interface to 8-wire operation. The instrumentation code, in
                 the case of a read-modify-write cycle, could result in receiving
                 a row where the hdsl2ShdslSpanConfWireInterface is set to 
                 twoWire(1) and pdnHdsl2ShdslSpanConfWireInterface is set to
                 eightWire(4). This could result in unpredictable results. 
                 This change will prevent the objects in the ExtTables from
                 existing in the same row as the objects in the standard tables
                 and prevent the unpredictable case from occurring."

    REVISION "200401161500Z"  -- January 16, 2004
    DESCRIPTION "Removed description text that implies that this MIB only applies 
                 to G.shdsl.bis. Add a table to allow the device to be configured
                 in CPE mode or CO mode."

    REVISION "200311061500Z"  -- November 6, 2003
    DESCRIPTION "Clean up, typo corrections, and clarifications."

    REVISION "200310231500Z"  -- October 23, 2003
    DESCRIPTION "Initial release."


::=  { pdn-interfaces 23 }


-- =============================================================================
-- == Define groups for Notifications, MIB Objects, Accessible for            ==
-- == Notifications (AFNs), and Conformance.                                  ==
-- == These may just be place holders.                                        ==
-- =============================================================================
pdnHdsl2ShdslLineNotifications OBJECT IDENTIFIER ::= { pdnHdsl2ShdslLineMIB 0 }
pdnHdsl2ShdslLineObjects       OBJECT IDENTIFIER ::= { pdnHdsl2ShdslLineMIB 1 }
pdnHdsl2ShdslLineAFNs          OBJECT IDENTIFIER ::= { pdnHdsl2ShdslLineMIB 2 } 
pdnHdsl2ShdslLineConformance   OBJECT IDENTIFIER ::= { pdnHdsl2ShdslLineMIB 3 }


-- =============================================================================
-- ==                  Textual Conventions                                    ==
-- =============================================================================

PdnHdsl2ShdslWirePair  ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION "This is the referenced pair of wires in a DSL Segment. HDSL2
                 only supports a single pair (wirePair1), while SHDSL supports an 
                 optional second pair (wirePair2), third pair (wirePair3), and a 
                 forth pair (wirePair4)."
    SYNTAX      INTEGER {
                    wirePair1(1),
                    wirePair2(2),
                    wirePair3(3),
                    wirePair4(4)
                }     



-- =============================================================================
-- ==                  MIB Objects                                            ==
-- =============================================================================


-- =============================================================================
-- == pdnHdsl2ShdslSpanStatusTable                                            ==
-- =============================================================================
pdnHdsl2ShdslSpanStatusExtTable   OBJECT-TYPE
    SYNTAX      SEQUENCE OF PdnHdsl2ShdslSpanStatusExtEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "This table extends the hdsl2ShdslSpanStatusTable defined in the
                 HDSL2-SHDSL-LINE-MIB (the `standard' MIB) which provides overall
                 information of DSL spans."
    ::= { pdnHdsl2ShdslLineObjects 1 }

pdnHdsl2ShdslSpanStatusExtEntry     OBJECT-TYPE
    SYNTAX      PdnHdsl2ShdslSpanStatusExtEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "An entry extends the hdsl2ShdslSpanStatusEntry defined in
                 [RFC 3276]. Each entry corresponds to a DSL line."
    INDEX       { ifIndex }
    ::= { pdnHdsl2ShdslSpanStatusExtTable 1 }

PdnHdsl2ShdslSpanStatusExtEntry ::=
    SEQUENCE {
        pdnHdsl2ShdslStatusMaxAttainableLineRate    Unsigned32,
        pdnHdsl2ShdslStatusActualLineRate           Unsigned32
    }

pdnHdsl2ShdslStatusMaxAttainableLineRate OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "bps"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Contains the maximum attainable line rate, in bps, in this
                 DSL span."
    REFERENCE   "RFC 3276, hdsl2ShdslStatusMaxAttainableLineRate."
    ::= { pdnHdsl2ShdslSpanStatusExtEntry 1 }

pdnHdsl2ShdslStatusActualLineRate OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "bps"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Contains the actual line rate, in bps, in this DSL span.
                 This is based upon measurements made during line probing."
    REFERENCE   "RFC 3276, hdsl2ShdslStatusActualLineRate."
    ::= { pdnHdsl2ShdslSpanStatusExtEntry 2 }


-- ===========================================================================
-- == pdnHdsl2ShdslEndpointConfTable                                        ==
-- ===========================================================================
pdnHdsl2ShdslEndpointConfTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PdnHdsl2ShdslEndpointConfEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "This table supports configuration parameters for segment
                 endpoints in a HDSL2/SHDSL line.  As this table is indexed
                 by ifIndex, it MUST be maintained in a persistent manner."
    REFERENCE   "RFC 3276, hdsl2ShdslEndpointConfTable."
    ::= { pdnHdsl2ShdslLineObjects 2 }

pdnHdsl2ShdslEndpointConfEntry OBJECT-TYPE
    SYNTAX      PdnHdsl2ShdslEndpointConfEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "Each entry represents a single segment endpoint in a HDSL2/SHDSL 
                 line. It is indexed by the ifIndex of the HDSL2/SHDSL line, the
                 UnitId of the associated unit, the side of the unit, and the
                 wire-pair of the associated modem."
    INDEX { ifIndex, hdsl2ShdslInvIndex, hdsl2ShdslEndpointSide, 
            pdnHdsl2ShdslEndpointWirePair }
    ::= { pdnHdsl2ShdslEndpointConfTable 1 }

PdnHdsl2ShdslEndpointConfEntry ::=
    SEQUENCE {
        pdnHdsl2ShdslEndpointWirePair               PdnHdsl2ShdslWirePair,
        pdnHdsl2ShdslEndpointAlarmConfProfile       SnmpAdminString
    }

pdnHdsl2ShdslEndpointWirePair OBJECT-TYPE
    SYNTAX      PdnHdsl2ShdslWirePair
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "The wire-pair of the modem associated with this segment
                 endpoint as per the PdnHdsl2ShdslWirePair textual convention."
     REFERENCE   "RFC 3276, hdsl2ShdslEndpointWirePair."
   ::= { pdnHdsl2ShdslEndpointConfEntry 1 }

pdnHdsl2ShdslEndpointAlarmConfProfile OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE(0..32))
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION "This object configures the alarm threshold values to be used
                 for this segment endpoint.  The values are obtained from the
                 alarm configuration profile referenced by this object.  The
                 value of this object is the index of the referenced profile in
                 the hdsl2ShdslEndpointAlarmConfProfileTable, or NULL (a zero-
                 length SnmpAdminString).  If the value is a zero-length
                 SnmpAdminString, the endpoint uses the default Alarm
                 Configuration Profile for the associated span as per the
                 hdsl2ShdslSpanConfAlarmProfile object in the
                 hdsl2ShdslSpanConfTable.  The default value of this object is
                 a zero-length SnmpAdminString.

                 Any attempt to set this object to a value that is not the value
                 of the index for an active entry in the profile table,
                 hdsl2ShdslEndpointAlarmConfProfileTable, MUST be rejected."
     REFERENCE   "RFC 3276, hdsl2ShdslEndpointAlarmConfProfile."
    ::= { pdnHdsl2ShdslEndpointConfEntry 2 }


-- =============================================================================
-- == pdnHdsl2ShdslEndpointCurrTable                                          ==
-- =============================================================================
pdnHdsl2ShdslEndpointCurrTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PdnHdsl2ShdslEndpointCurrEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "This table contains current status and performance information
                 for segment endpoints in HDSL2/SHDSL Lines.  As with other
                 tables in this MIB indexed by ifIndex, entries in this table
                 MUST be maintained in a persistent manner."
    REFERENCE   "RFC 3276, hdsl2ShdslEndpointCurrTable."
    ::= { pdnHdsl2ShdslLineObjects 3 }

pdnHdsl2ShdslEndpointCurrEntry OBJECT-TYPE
    SYNTAX      PdnHdsl2ShdslEndpointCurrEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "Each entry contains status and performance information relating 
                 to a single segment endpoint.  It is indexed by the ifIndex of 
                 the HDSL2/SHDSL line, the UnitId of the associated unit, the 
                 side of the unit, and the wire-pair of the associated modem."
    INDEX { ifIndex, hdsl2ShdslInvIndex, hdsl2ShdslEndpointSide,
            pdnHdsl2ShdslEndpointWirePair }
    ::= { pdnHdsl2ShdslEndpointCurrTable 1 }

PdnHdsl2ShdslEndpointCurrEntry ::=
    SEQUENCE {
        pdnHdsl2ShdslEndpointCurrAtn                Integer32,
        pdnHdsl2ShdslEndpointCurrSnrMgn             Integer32,
        pdnHdsl2ShdslEndpointCurrStatus             BITS,
        pdnHdsl2ShdslEndpointES                     Counter32,
        pdnHdsl2ShdslEndpointSES                    Counter32,
        pdnHdsl2ShdslEndpointCRCanomalies           Counter32,
        pdnHdsl2ShdslEndpointLOSWS                  Counter32,
        pdnHdsl2ShdslEndpointUAS                    Counter32,
        pdnHdsl2ShdslEndpointCurr15MinTimeElapsed   Hdsl2ShdslPerfTimeElapsed,
        pdnHdsl2ShdslEndpointCurr15MinES            PerfCurrentCount,
        pdnHdsl2ShdslEndpointCurr15MinSES           PerfCurrentCount,
        pdnHdsl2ShdslEndpointCurr15MinCRCanomalies  PerfCurrentCount,
        pdnHdsl2ShdslEndpointCurr15MinLOSWS         PerfCurrentCount,
        pdnHdsl2ShdslEndpointCurr15MinUAS           PerfCurrentCount,
        pdnHdsl2ShdslEndpointCurr1DayTimeElapsed    Hdsl2ShdslPerfTimeElapsed,
        pdnHdsl2ShdslEndpointCurr1DayES             Hdsl2ShdslPerfCurrDayCount,
        pdnHdsl2ShdslEndpointCurr1DaySES            Hdsl2ShdslPerfCurrDayCount,
        pdnHdsl2ShdslEndpointCurr1DayCRCanomalies   Hdsl2ShdslPerfCurrDayCount,
        pdnHdsl2ShdslEndpointCurr1DayLOSWS          Hdsl2ShdslPerfCurrDayCount,
        pdnHdsl2ShdslEndpointCurr1DayUAS            Hdsl2ShdslPerfCurrDayCount
    }

pdnHdsl2ShdslEndpointCurrAtn OBJECT-TYPE
    SYNTAX      Integer32(-127..128)
    UNITS       "dB"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "The current loop attenuation for this endpoint as reported in
                 a Network or Customer Side Performance Status message."
    REFERENCE   "RFC 3276, hdsl2ShdslEndpointCurrAtn."
   ::= { pdnHdsl2ShdslEndpointCurrEntry 1 }

pdnHdsl2ShdslEndpointCurrSnrMgn OBJECT-TYPE
    SYNTAX      Integer32(-127..128)
    UNITS       "dB"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "The current SNR margin for this endpoint as reported in a
                 Status Response/SNR message."
    REFERENCE   "RFC 3276, hdsl2ShdslEndpointCurrSnrMgn."
    ::= { pdnHdsl2ShdslEndpointCurrEntry 2 }

pdnHdsl2ShdslEndpointCurrStatus OBJECT-TYPE
    SYNTAX      BITS {
                    noDefect(0),
                    powerBackoff(1),
                    deviceFault(2),
                    dcContinuityFault(3),
                    snrMarginAlarm(4),
                    loopAttenuationAlarm(5),
                    loswFailureAlarm(6),
                    configInitFailure(7),
                    protocolInitFailure(8),
                    noNeighborPresent(9),
                    loopbackActive(10)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Contains the current state of the endpoint.  This is a
                 bitmap of possible conditions. The various bit positions
                 are:

                     noDefect               There no defects on the line.

                     powerBackoff           Indicates enhanced Power Backoff.

                     deviceFault            Indicates a vendor-dependent
                                            diagnostic or self-test fault
                                            has been detected.

                     dcContinuityFault      Indicates vendor-dependent
                                            conditions that interfere with
                                            span powering such as short and
                                            open circuits.

                     snrMarginAlarm         Indicates that the SNR margin
                                            has dropped below the alarm threshold.

                     loopAttenuationAlarm   Indicates that the loop attenuation
                                            exceeds the alarm threshold.

                     loswFailureAlarm       Indicates a forward LOSW alarm.

                     configInitFailure      Endpoint failure during initialization
                                            due to paired endpoint not able to
                                            support requested configuration.

                     protocolInitFailure    Endpoint failure during initialization
                                            due to incompatible protocol used by
                                            the paired endpoint.

                     noNeighborPresent      Endpoint failure during initialization
                                            due to no activation sequence detected
                                            from paired endpoint.

                     loopbackActive         A loopback is currently active at this
                                            Segment Endpoint.

                 This is intended to supplement ifOperStatus.  Note that there
                 is a 1-1 relationship between the status bits defined in this
                 object and the notification thresholds defined elsewhere in
                 this MIB."
    REFERENCE   "RFC 3276, hdsl2ShdslEndpointCurrStatus."
    ::= { pdnHdsl2ShdslEndpointCurrEntry 3 }

pdnHdsl2ShdslEndpointES OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Count of Errored Seconds (ES) on this endpoint since the xU
                 was last restarted."
    REFERENCE   "RFC 3276, hdsl2ShdslEndpointES."
    ::= { pdnHdsl2ShdslEndpointCurrEntry 4 }

pdnHdsl2ShdslEndpointSES OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Count of Severely Errored Seconds (SES) on this endpoint
                 since the xU was last restarted."
    REFERENCE   "RFC 3276, hdsl2ShdslEndpointSES."
    ::= { pdnHdsl2ShdslEndpointCurrEntry 5 }

pdnHdsl2ShdslEndpointCRCanomalies OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "detected CRC Anomalies"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Count of CRC anomalies on this endpoint since the xU was
                 last restarted."
    REFERENCE   "RFC 3276, hdsl2ShdslEndpointCRCanomalies."
    ::= { pdnHdsl2ShdslEndpointCurrEntry 6 }

pdnHdsl2ShdslEndpointLOSWS OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Count of Loss of Sync Word (LOSW) Seconds on this endpoint
                 since the xU was last restarted."
    REFERENCE   "RFC 3276, hdsl2ShdslEndpointLOSWS."
    ::= { pdnHdsl2ShdslEndpointCurrEntry 7 }

pdnHdsl2ShdslEndpointUAS OBJECT-TYPE
    SYNTAX      Counter32
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Count of Unavailable Seconds (UAS) on this endpoint since
                 the xU was last restarted."
    REFERENCE   "RFC 3276, hdsl2ShdslEndpointUAS."
    ::= { pdnHdsl2ShdslEndpointCurrEntry 8 }

pdnHdsl2ShdslEndpointCurr15MinTimeElapsed OBJECT-TYPE
    SYNTAX      Hdsl2ShdslPerfTimeElapsed
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Total elapsed seconds in the current 15-minute interval."
    REFERENCE   "RFC 3276, hdsl2ShdslEndpointCurr15MinTimeElapsed."
    ::= { pdnHdsl2ShdslEndpointCurrEntry 9 }

pdnHdsl2ShdslEndpointCurr15MinES OBJECT-TYPE
    SYNTAX      PerfCurrentCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Count of Errored Seconds (ES) in the current 15-minute
                 interval."
    REFERENCE   "RFC 3276, hdsl2ShdslEndpointCurr15MinES."
    ::= { pdnHdsl2ShdslEndpointCurrEntry 10 }

pdnHdsl2ShdslEndpointCurr15MinSES OBJECT-TYPE
    SYNTAX      PerfCurrentCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Count of Severely Errored Seconds (SES) in the current
                 15-minute interval."
    REFERENCE   "RFC 3276, hdsl2ShdslEndpointCurr15MinSES."
    ::= { pdnHdsl2ShdslEndpointCurrEntry 11 }

pdnHdsl2ShdslEndpointCurr15MinCRCanomalies OBJECT-TYPE
    SYNTAX      PerfCurrentCount
    UNITS       "detected CRC Anomalies"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Count of CRC anomalies in the current 15-minute interval."
    REFERENCE   "RFC 3276, hdsl2ShdslEndpointCurr15MinCRCanomalies."
    ::= { pdnHdsl2ShdslEndpointCurrEntry 12 }

pdnHdsl2ShdslEndpointCurr15MinLOSWS OBJECT-TYPE
    SYNTAX      PerfCurrentCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Count of Loss of Sync Word (LOSW) Seconds in the current
                 15-minute interval."
    REFERENCE   "RFC 3276, hdsl2ShdslEndpointCurr15MinLOSWS."
    ::= { pdnHdsl2ShdslEndpointCurrEntry 13 }

pdnHdsl2ShdslEndpointCurr15MinUAS OBJECT-TYPE
    SYNTAX      PerfCurrentCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Count of Unavailable Seconds (UAS) in the current 15-minute
                 interval."
    REFERENCE   "RFC 3276, hdsl2ShdslEndpointCurr15MinUAS."
    ::= { pdnHdsl2ShdslEndpointCurrEntry 14 }

pdnHdsl2ShdslEndpointCurr1DayTimeElapsed OBJECT-TYPE
    SYNTAX      Hdsl2ShdslPerfTimeElapsed
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Number of seconds that have elapsed since the beginning of
                 the current 1-day interval."
    REFERENCE   "RFC 3276, hdsl2ShdslEndpointCurr1DayTimeElapsed."
    ::= { pdnHdsl2ShdslEndpointCurrEntry 15 }

pdnHdsl2ShdslEndpointCurr1DayES OBJECT-TYPE
    SYNTAX      Hdsl2ShdslPerfCurrDayCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Count of Errored Seconds (ES) during the current day as
                 measured by pdnHdsl2ShdslEndpointCurr1DayTimeElapsed."
    REFERENCE   "RFC 3276, hdsl2ShdslEndpointCurr1DayES."
    ::= { pdnHdsl2ShdslEndpointCurrEntry 16 }

pdnHdsl2ShdslEndpointCurr1DaySES OBJECT-TYPE
    SYNTAX      Hdsl2ShdslPerfCurrDayCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Count of Severely Errored Seconds (SES) during the current
                 day as measured by pdnHdsl2ShdslEndpointCurr1DayTimeElapsed."
    REFERENCE   "RFC 3276, hdsl2ShdslEndpointCurr1DaySES."
    ::= { pdnHdsl2ShdslEndpointCurrEntry 17 }

pdnHdsl2ShdslEndpointCurr1DayCRCanomalies OBJECT-TYPE
    SYNTAX      Hdsl2ShdslPerfCurrDayCount
    UNITS       "detected CRC Anomalies"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Count of CRC anomalies during the current day as measured
                 by pdnHdsl2ShdslEndpointCurr1DayTimeElapsed."
    REFERENCE   "RFC 3276, hdsl2ShdslEndpointCurr1DayCRCanomalies."
    ::= { pdnHdsl2ShdslEndpointCurrEntry 18 }

pdnHdsl2ShdslEndpointCurr1DayLOSWS OBJECT-TYPE
    SYNTAX      Hdsl2ShdslPerfCurrDayCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Count of Loss of Sync Word (LOSW) Seconds during the current
                 day as measured by pdnHdsl2ShdslEndpointCurr1DayTimeElapsed."
    REFERENCE   "RFC 3276, hdsl2ShdslEndpointCurr1DayLOSWS."
    ::= { pdnHdsl2ShdslEndpointCurrEntry 19 }

pdnHdsl2ShdslEndpointCurr1DayUAS OBJECT-TYPE
    SYNTAX      Hdsl2ShdslPerfCurrDayCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Count of Unavailable Seconds (UAS) during the current day as
                 measured by pdnHdsl2ShdslEndpointCurr1DayTimeElapsed."
    REFERENCE   "RFC 3276, hdsl2ShdslEndpointCurr1DayUAS."
    ::= { pdnHdsl2ShdslEndpointCurrEntry 20 }


-- =============================================================================
-- == pdhHdsl2Shdsl15MinIntervalTable                                         ==
-- =============================================================================
pdnHdsl2Shdsl15MinIntervalTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PdnHdsl2Shdsl15MinIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "This table provides one row for each HDSL2/SHDSL endpoint
                 performance data collection interval.  This table contains
                 live data from equipment.  As such, it is NOT persistent."
    REFERENCE   "RFC 3276, hdsl2Shdsl15MinIntervalTable."
    ::= { pdnHdsl2ShdslLineObjects 4 }

pdnHdsl2Shdsl15MinIntervalEntry OBJECT-TYPE
    SYNTAX      PdnHdsl2Shdsl15MinIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "An entry in the pdnHdsl2Shdsl15MinIntervalTable."
    INDEX { ifIndex, hdsl2ShdslInvIndex, hdsl2ShdslEndpointSide,
            pdnHdsl2ShdslEndpointWirePair, pdnHdsl2Shdsl15MinIntervalNumber }
    ::= { pdnHdsl2Shdsl15MinIntervalTable 1 }

PdnHdsl2Shdsl15MinIntervalEntry ::=
    SEQUENCE {
        pdnHdsl2Shdsl15MinIntervalNumber         Unsigned32,
        pdnHdsl2Shdsl15MinIntervalES             PerfIntervalCount,
        pdnHdsl2Shdsl15MinIntervalSES            PerfIntervalCount,
        pdnHdsl2Shdsl15MinIntervalCRCanomalies   PerfIntervalCount,
        pdnHdsl2Shdsl15MinIntervalLOSWS          PerfIntervalCount,
        pdnHdsl2Shdsl15MinIntervalUAS            PerfIntervalCount
    }

pdnHdsl2Shdsl15MinIntervalNumber OBJECT-TYPE
    SYNTAX      Unsigned32(1..96)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "Performance Data Interval number. 1 is the the most recent
                 previous interval; interval 96 is 24 hours ago. Intervals
                 2..96 are optional."
    REFERENCE   "RFC 3276, hdsl2Shdsl15MinIntervalNumber."
    ::= { pdnHdsl2Shdsl15MinIntervalEntry 1 }

pdnHdsl2Shdsl15MinIntervalES OBJECT-TYPE
    SYNTAX      PerfIntervalCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Count of Errored Seconds (ES) during the interval."
    REFERENCE   "RFC 3276, hdsl2Shdsl15MinIntervalES."
    ::= { pdnHdsl2Shdsl15MinIntervalEntry 2 }

pdnHdsl2Shdsl15MinIntervalSES OBJECT-TYPE
    SYNTAX      PerfIntervalCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Count of Severely Errored Seconds (SES) during the interval."
    REFERENCE   "RFC 3276, hdsl2Shdsl15MinIntervalSES."
    ::= { pdnHdsl2Shdsl15MinIntervalEntry 3 }

pdnHdsl2Shdsl15MinIntervalCRCanomalies OBJECT-TYPE
    SYNTAX      PerfIntervalCount
    UNITS       "detected CRC Anomalies"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Count of CRC anomalies during the interval."
    REFERENCE   "RFC 3276, hdsl2Shdsl15MinIntervalCRCanomalies."
    ::= { pdnHdsl2Shdsl15MinIntervalEntry 4 }

pdnHdsl2Shdsl15MinIntervalLOSWS OBJECT-TYPE
    SYNTAX      PerfIntervalCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Count of Loss of Sync Word (LOSW) Seconds during the
                 interval."
    REFERENCE   "RFC 3276, hdsl2Shdsl15MinIntervalLOSWS."
    ::= { pdnHdsl2Shdsl15MinIntervalEntry 5 }

pdnHdsl2Shdsl15MinIntervalUAS OBJECT-TYPE
    SYNTAX      PerfIntervalCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Count of Unavailable Seconds (UAS) during the interval."
    REFERENCE   "RFC 3276, hdsl2Shdsl15MinIntervalUAS."
    ::= { pdnHdsl2Shdsl15MinIntervalEntry 6 }


-- =============================================================================
-- == pdnHdsl2Shdsl1DayIntervalTable                                          ==
-- =============================================================================
pdnHdsl2Shdsl1DayIntervalTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PdnHdsl2Shdsl1DayIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "This table provides one row for each HDSL2/SHDSL endpoint
                 performance data collection interval.  This table contains
                 live data from equipment.  As such, it is NOT persistent."
    REFERENCE   "RFC 3276, hdsl2Shdsl1DayIntervalTable."
    ::= { pdnHdsl2ShdslLineObjects 5 }

pdnHdsl2Shdsl1DayIntervalEntry OBJECT-TYPE
    SYNTAX      PdnHdsl2Shdsl1DayIntervalEntry
    MAX-ACCESS  not-accessible
    STATUS      current

    DESCRIPTION "An entry in the pdnHdsl2Shdsl1DayIntervalTable."
    INDEX { ifIndex, hdsl2ShdslInvIndex, hdsl2ShdslEndpointSide,
            pdnHdsl2ShdslEndpointWirePair, pdnHdsl2Shdsl1DayIntervalNumber }
    ::= { pdnHdsl2Shdsl1DayIntervalTable 1 }

PdnHdsl2Shdsl1DayIntervalEntry ::=
    SEQUENCE {
        pdnHdsl2Shdsl1DayIntervalNumber         Unsigned32,
        pdnHdsl2Shdsl1DayIntervalMoniSecs       Hdsl2ShdslPerfTimeElapsed,
        pdnHdsl2Shdsl1DayIntervalES             Hdsl2Shdsl1DayIntervalCount,
        pdnHdsl2Shdsl1DayIntervalSES            Hdsl2Shdsl1DayIntervalCount,
        pdnHdsl2Shdsl1DayIntervalCRCanomalies   Hdsl2Shdsl1DayIntervalCount,
        pdnHdsl2Shdsl1DayIntervalLOSWS          Hdsl2Shdsl1DayIntervalCount,
        pdnHdsl2Shdsl1DayIntervalUAS            Hdsl2Shdsl1DayIntervalCount
    }

pdnHdsl2Shdsl1DayIntervalNumber OBJECT-TYPE
    SYNTAX      Unsigned32(1..30)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "History Data Interval number. Interval 1 is the the most
                 recent previous day; interval 30 is 30 days ago. Intervals
                 2..30 are optional."
    REFERENCE   "RFC 3276, hdsl2Shdsl1DayIntervalNumber."
    ::= { pdnHdsl2Shdsl1DayIntervalEntry 1 }

pdnHdsl2Shdsl1DayIntervalMoniSecs OBJECT-TYPE
    SYNTAX      Hdsl2ShdslPerfTimeElapsed
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "The amount of time in the 1-day interval over which the
                 performance monitoring information is actually counted.
                 This value will be the same as the interval duration except
                 in a situation where performance monitoring data could not
                 be collected for any reason."
    REFERENCE   "RFC 3276, hdsl2Shdsl1DayIntervalMoniSecs."
    ::= { pdnHdsl2Shdsl1DayIntervalEntry 2 }

pdnHdsl2Shdsl1DayIntervalES OBJECT-TYPE
    SYNTAX       Hdsl2Shdsl1DayIntervalCount
    UNITS        "seconds"
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION "Count of Errored Seconds (ES) during the 1-day interval as
                 measured by pdnHdsl2Shdsl1DayIntervalMoniSecs."
    REFERENCE   "RFC 3276, hdsl2Shdsl1DayIntervalES."
    ::= { pdnHdsl2Shdsl1DayIntervalEntry 3 }

pdnHdsl2Shdsl1DayIntervalSES OBJECT-TYPE
    SYNTAX      Hdsl2Shdsl1DayIntervalCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Count of Severely Errored Seconds (SES) during the 1-day
                 interval as measured by pdnHdsl2Shdsl1DayIntervalMoniSecs."
    REFERENCE   "RFC 3276, hdsl2Shdsl1DayIntervalSES."
    ::= { pdnHdsl2Shdsl1DayIntervalEntry 4 }

pdnHdsl2Shdsl1DayIntervalCRCanomalies OBJECT-TYPE
    SYNTAX      Hdsl2Shdsl1DayIntervalCount
    UNITS       "detected CRC Anomalies"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Count of CRC anomalies during the 1-day interval as
                 measured by pdnHdsl2Shdsl1DayIntervalMoniSecs."
    REFERENCE   "RFC 3276, hdsl2Shdsl1DayIntervalCRCanomalies."
    ::= { pdnHdsl2Shdsl1DayIntervalEntry 5 }

pdnHdsl2Shdsl1DayIntervalLOSWS OBJECT-TYPE
    SYNTAX      Hdsl2Shdsl1DayIntervalCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Count of Loss of Sync Word (LOSW) Seconds during the 1-day
                 interval as measured by pdnHdsl2Shdsl1DayIntervalMoniSecs."
    REFERENCE   "RFC 3276, hdsl2Shdsl1DayIntervalLOSWS."
    ::= { pdnHdsl2Shdsl1DayIntervalEntry 6 }

pdnHdsl2Shdsl1DayIntervalUAS OBJECT-TYPE
    SYNTAX      Hdsl2Shdsl1DayIntervalCount
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Count of Unavailable Seconds (UAS) during the 1-day interval
                 as measured by pdnHdsl2Shdsl1DayIntervalMoniSecs."
    REFERENCE   "RFC 3276, hdsl2Shdsl1DayIntervalUAS."
    ::= { pdnHdsl2Shdsl1DayIntervalEntry 7 }


-- =============================================================================
-- == pdnHdsl2ShdslSpanConfProfileExtTable                                    ==
-- =============================================================================
pdnHdsl2ShdslSpanConfProfileExtTable       OBJECT-TYPE
    SYNTAX      SEQUENCE OF PdnHdsl2ShdslSpanConfProfileExtEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "This table extends the hdsl2ShdslSpanConfProfileTable defined in 
                 the HDSL2-SHDSL-LINE-MIB (the `standard' MIB) which supports
                 definitions of span configuration profiles for DSL lines.

                 IMPORTANT NOTE:  This table is a 'pseudo-augments' of the
                 hdsl2ShdslSpanConfProfileTable. Refer to the April 21, 2004
                 revision description for a discussion on why the table is
                 indexed as opposed to augments. This table shares the same 
                 table table index as the hdsl2ShdslSpanConfProfileTable.
                 However, this table does not have a row status object. Therefore,
                 rows are created or deleted in this table by creating or 
                 deleting rows in the hdsl2ShdslSpanConfProfileTable."
    ::= { pdnHdsl2ShdslLineObjects 6 }

pdnHdsl2ShdslSpanConfProfileExtEntry     OBJECT-TYPE
    SYNTAX      PdnHdsl2ShdslSpanConfProfileExtEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "An entry extends the hdsl2ShdslSpanConfProfileEntry defined in
                 [RFC 3276]. Each entry corresponds to a profile for a span."
    INDEX       { IMPLIED hdsl2ShdslSpanConfProfileName }
    ::= { pdnHdsl2ShdslSpanConfProfileExtTable 1 }

PdnHdsl2ShdslSpanConfProfileExtEntry ::=
    SEQUENCE {
        pdnHdsl2ShdslSpanConfWireInterface  INTEGER,
        pdnHdsl2ShdslSpanConfMinLineRate    Unsigned32,
        pdnHdsl2ShdslSpanConfMaxLineRate    Unsigned32
    }


pdnHdsl2ShdslSpanConfWireInterface OBJECT-TYPE
    SYNTAX      INTEGER {
                    twoWire(1),
                    fourWire(2),
                    sixWire(3),
                    eightWire(4)
                }
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION "This object configures number of wires that are operational for
                 this span. The following values are defined for this object:
                     twoWire(1)    - 2-wire mode
                     fourWire(2)   - 4-wire mode
                     sixWire(3)    - 6-wire mode
                     eightWire(4)  - 8-wire mode"
    REFERENCE   "RFC 3276, hdsl2ShdslSpanConfWireInterface."
    DEFVAL      { twoWire }
    ::= { pdnHdsl2ShdslSpanConfProfileExtEntry 1 }

pdnHdsl2ShdslSpanConfMinLineRate OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "bps"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION "This object configures the minimum transmission rate,
                 in multiples of 64 kbits per second, for the associated 
                 DSL Line in bits-per-second (bps). If the minimum line rate 
                 equals the maximum line rate (pdnHdsl2ShdslSpanConfMaxLineRate), 
                 the line rate is considered `fixed'. If the minimum line rate 
                 is less than the maximum line rate, the line is considered 
                 `rate-adaptive'."
    REFERENCE   "RFC 3276, hdsl2ShdslSpanConfMinLineRate."
    DEFVAL      { 155200 }
    ::= { pdnHdsl2ShdslSpanConfProfileExtEntry 2 }

pdnHdsl2ShdslSpanConfMaxLineRate OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "bps"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION "This object configures the maximum transmission rate, in
                 multiples of 64 kbits per second, for the associated DSL Line 
                 in bits-per-second (bps). If the minimum line rate (pdnHdsl2Shdsl-
                 SpanConfMinLineRate) equals the maximum line rate, the line 
                 rate is considered `fixed'. if the minimum line rate is less 
                 than the maximum line rate, the line rate is considered 
                 `rate-adaptive'."
    REFERENCE   "RFC 3276, hdsl2ShdslSpanConfMaxLineRate."
    DEFVAL      { 155200 }
    ::= { pdnHdsl2ShdslSpanConfProfileExtEntry 3 }


-- =============================================================================
-- == pdhHdsl2ShdslIfTable                                                    ==
-- =============================================================================
pdnHdsl2ShdslIfTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PdnHdsl2ShdslIfEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "This table provides objects related to a particular interface
                 and each entry corresponds to an ifIndex."
    ::= { pdnHdsl2ShdslLineObjects 7 }

pdnHdsl2ShdslIfEntry OBJECT-TYPE
    SYNTAX      PdnHdsl2ShdslIfEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "An entry in the pdnHdsl2ShdslIfTableTable."
    INDEX { ifIndex }
    ::= { pdnHdsl2ShdslIfTable 1 }

PdnHdsl2ShdslIfEntry ::=
    SEQUENCE {
        pdnHdsl2ShdslIfTableEquipMode            INTEGER
    }

pdnHdsl2ShdslIfTableEquipMode OBJECT-TYPE
    SYNTAX      INTEGER {
                    coMode(1),      -- Central Office Mode
                    cpeMode(2)      -- Customer Premise Equipment Mode
    }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION "This object allows the mode of the equipment to be set."                 
    ::= { pdnHdsl2ShdslIfEntry 1 }

-- =============================================================================
-- == Extended Rate Mode                                                      ==
-- =============================================================================
pdnHdsl2ShdslExtendedRateMode OBJECT-TYPE
    SYNTAX      INTEGER {
                    disabled(1),
                    payload5696(2)
    }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION "This object is used to select a mode of operation that 
                 supports extended rates.  Some hardware implementations
                 require different configurations base on whether or not
                 higher speed rates are desired.  For example, an 
                 implementation may require different code be loaded in 
                 a digital signal processor or an implementation may 
                 dictate that fewer subscriber ports are supported for
                 a higher data rate.  The payload5696(2) corresponds to the
                 5696 kbits per second rate specified in G.991.2, Annex F."
    ::= { pdnHdsl2ShdslLineObjects 8 }



-- =============================================================================
-- ==                  Accessible for Notifications (AFNs)                    ==
-- =============================================================================
-- None defined



-- =============================================================================
-- ==                  Traps/Notifications                                    ==
-- =============================================================================

pdnHdsl2ShdslLoopAttenCrossing NOTIFICATION-TYPE
    OBJECTS {
        pdnHdsl2ShdslEndpointCurrAtn,
        hdsl2ShdslEndpointThreshLoopAttenuation
    }
    STATUS      current
    DESCRIPTION "This notification indicates that the loop attenuation
                 threshold (as per the hdsl2ShdslEndpointThreshLoopAttenuation
                 value) has been reached/exceeded for the DSL segment
                 endpoint."
    REFERENCE   "RFC 3276 hdsl2ShdslLoopAttenCrossing."
    ::= { pdnHdsl2ShdslLineNotifications 1 }

pdnHdsl2ShdslSNRMarginCrossing NOTIFICATION-TYPE
    OBJECTS {
        pdnHdsl2ShdslEndpointCurrSnrMgn,
        hdsl2ShdslEndpointThreshSNRMargin
    }
    STATUS      current
    DESCRIPTION "This notification indicates that the SNR margin threshold (as
                 per the hdsl2ShdslEndpointThreshSNRMargin value) has been
                 reached/exceeded for the DSL segment endpoint."
    REFERENCE   "RFC 3276 hdsl2ShdslSNRMarginCrossing."
    ::= { pdnHdsl2ShdslLineNotifications 2 }

pdnHdsl2ShdslPerfESThresh NOTIFICATION-TYPE
    OBJECTS {
        pdnHdsl2ShdslEndpointCurr15MinES,
        hdsl2ShdslEndpointThreshES
    }
    STATUS      current
    DESCRIPTION "This notification indicates that the errored seconds threshold
                 (as per the hdsl2ShdslEndpointThreshES value) has been reached/
                 exceeded for the DSL segment endpoint."
    REFERENCE   "RFC 3276 hdsl2ShdslPerfESThresh."
    ::= { pdnHdsl2ShdslLineNotifications 3 }

pdnHdsl2ShdslPerfSESThresh NOTIFICATION-TYPE
    OBJECTS {
        pdnHdsl2ShdslEndpointCurr15MinSES,
        hdsl2ShdslEndpointThreshSES
    }
    STATUS      current
    DESCRIPTION "This notification indicates that the severely errored seconds
                 threshold (as per the hdsl2ShdslEndpointThreshSES value) has
                 been reached/exceeded for the DSL Segment Endpoint."
    REFERENCE   "RFC 3276 hdsl2ShdslPerfSESThresh."
    ::= { pdnHdsl2ShdslLineNotifications 4 }

pdnHdsl2ShdslPerfCRCanomaliesThresh NOTIFICATION-TYPE
    OBJECTS {
        pdnHdsl2ShdslEndpointCurr15MinCRCanomalies,
        hdsl2ShdslEndpointThreshCRCanomalies
    }
    STATUS      current
    DESCRIPTION "This notification indicates that the CRC anomalies threshold
                 (as per the hdsl2ShdslEndpointThreshCRCanomalies value) has
                 been reached/exceeded for the DSL Segment Endpoint."
    REFERENCE   "RFC 3276 hdsl2ShdslPerfCRCanomaliesThresh."
    ::= { pdnHdsl2ShdslLineNotifications 5 }

pdnHdsl2ShdslPerfLOSWSThresh NOTIFICATION-TYPE
    OBJECTS {
        pdnHdsl2ShdslEndpointCurr15MinLOSWS,
        hdsl2ShdslEndpointThreshLOSWS
    }
    STATUS      current
    DESCRIPTION "This notification indicates that the LOSW seconds threshold
                 (as per the hdsl2ShdslEndpointThreshLOSWS value) has been
                 reached/exceeded for the DSL segment endpoint."
    REFERENCE   "RFC 3276 hdsl2ShdslPerfLOSWSThresh."
    ::= { pdnHdsl2ShdslLineNotifications 6 }

pdnHdsl2ShdslPerfUASThresh NOTIFICATION-TYPE
    OBJECTS {
        pdnHdsl2ShdslEndpointCurr15MinUAS,
        hdsl2ShdslEndpointThreshUAS
    }
    STATUS      current
    DESCRIPTION "This notification indicates that the unavailable seconds
                 threshold (as per the hdsl2ShdslEndpointThreshUAS value) has
                 been reached/exceeded for the HDSL2/SHDSL segment endpoint."
    REFERENCE   "RFC 3276 hdsl2ShdslPerfUASThresh."
    ::= { pdnHdsl2ShdslLineNotifications 7 }

pdnHdsl2ShdslpowerBackoff NOTIFICATION-TYPE
    OBJECTS {
        pdnHdsl2ShdslEndpointCurrStatus
    }
    STATUS      current
    DESCRIPTION "This notification indicates that the bit setting for
                 powerBackoff in the pdnHdsl2ShdslEndpointCurrStatus object for
                 this endpoint has changed."
    REFERENCE   "RFC 3276 hdsl2ShdslpowerBackoff."
    ::= { pdnHdsl2ShdslLineNotifications 8 }

pdnHdsl2ShdsldeviceFault NOTIFICATION-TYPE
    OBJECTS {
        pdnHdsl2ShdslEndpointCurrStatus
    }
    STATUS      current
    DESCRIPTION "This notification indicates that the bit setting for
                 deviceFault in the pdnHdsl2ShdslEndpointCurrStatus object for
                 this endpoint has changed."
    REFERENCE   "RFC 3276 hdsl2ShdsldeviceFault."
    ::= { pdnHdsl2ShdslLineNotifications 9 }

pdnHdsl2ShdsldcContinuityFault NOTIFICATION-TYPE
    OBJECTS {
        pdnHdsl2ShdslEndpointCurrStatus
    }
    STATUS      current
    DESCRIPTION "This notification indicates that the bit setting for
                 dcContinuityFault in the pdnHdsl2ShdslEndpointCurrStatus object
                 for this endpoint has changed."
    REFERENCE   "RFC 3276 hdsl2ShdsldcContinuityFault."
    ::= { pdnHdsl2ShdslLineNotifications 10 }

pdnHdsl2ShdslconfigInitFailure NOTIFICATION-TYPE
    OBJECTS {
        pdnHdsl2ShdslEndpointCurrStatus
    }
    STATUS      current
    DESCRIPTION "This notification indicates that the bit setting for
                 configInitFailure in the pdnHdsl2ShdslEndpointCurrStatus object
                 for this endpoint has changed."
    REFERENCE   "RFC 3276 hdsl2ShdslconfigInitFailure."
    ::= { pdnHdsl2ShdslLineNotifications 11 }

pdnHdsl2ShdslprotocolInitFailure NOTIFICATION-TYPE
    OBJECTS {
        pdnHdsl2ShdslEndpointCurrStatus
    }
    STATUS      current
    DESCRIPTION "This notification indicates that the bit setting for
                 protocolInitFailure in the pdnHdsl2ShdslEndpointCurrStatus
                 object for this endpoint has changed."
    REFERENCE   "RFC 3276 hdsl2ShdslprotocolInitFailure."
    ::= { pdnHdsl2ShdslLineNotifications 12 }

pdnHdsl2ShdslnoNeighborPresent NOTIFICATION-TYPE
    OBJECTS {
        pdnHdsl2ShdslEndpointCurrStatus
    }
    STATUS    current
    DESCRIPTION "This notification indicates that the bit setting for
                 noNeighborPresent in the pdnHdsl2ShdslEndpointCurrStatus object
                 for this endpoint has changed."
    REFERENCE   "RFC 3276 hdsl2ShdslnoNeighborPresent."
    ::= { pdnHdsl2ShdslLineNotifications 13 }




-- =============================================================================
-- ==                  Conformance Information                                ==
-- =============================================================================

pdnHdsl2ShdslLineCompliances  OBJECT IDENTIFIER ::= { pdnHdsl2ShdslLineConformance 1 }
pdnHdsl2ShdslLineGroups       OBJECT IDENTIFIER ::= { pdnHdsl2ShdslLineConformance 2 }


-- ===========================
-- == Compliance Statements ==
-- ===========================


pdnHdsl2ShdslLineMIBCompliance MODULE-COMPLIANCE
    STATUS      current
    DESCRIPTION "The compliance statement for pdnHdsl2ShdslLineMIB entities which
                 implement the pdnHdsl2ShdslLineMIB."
    MODULE      -- this module
    -- No mandatory groups are specified

    GROUP       pdnHdsl2ShdslSpanShdslStatusGroup
    DESCRIPTION "This group is only required for G.shdsl.bis implementations and
                 where the `standard' MIB does not support G.shdsl.bis."

    GROUP       pdnHdsl2ShdslEndpointConfGroup
    DESCRIPTION "This group is only required for G.shdsl.bis implementations and
                 where the `standard' MIB does not support G.shdsl.bis."

    GROUP       pdnHdsl2ShdslEndpointCurrGroup
    DESCRIPTION "This group is only required for G.shdsl.bis implementations and
                 where the `standard' MIB does not support G.shdsl.bis."

    GROUP       pdnHdsl2Shdsl15MinIntervalGroup
    DESCRIPTION "This group is only required for G.shdsl.bis implementations and
                 where the `standard' MIB does not support G.shdsl.bis."

    GROUP       pdnHdsl2Shdsl1DayIntervalGroup
    DESCRIPTION "This group is only required for G.shdsl.bis implementations and
                 where the `standard' MIB does not support G.shdsl.bis."

    GROUP       pdnHdsl2ShdslSpanConfProfileGroup
    DESCRIPTION "This group is only required for G.shdsl.bis implementations and
                 where the `standard' MIB does not support G.shdsl.bis."

    GROUP       pdnHdsl2ShdslIfTableGroup
    DESCRIPTION "This group is only required if the relevant objects are need on
                 a per-interface basis."

    GROUP       pdnHdsl2ShdslExtendedRateModeGroup
    DESCRIPTION "This group is only required if the hardware implementation
                 requires a different configuration to support higher rates
                 such as G.991.2 Annex F.  The object(s) in this group serve
                 to indicate if extended base data rates are desired."

    GROUP       pdnHdsl2ShdslNotificationGroup
    DESCRIPTION "This group is only required for G.shdsl.bis implementations and
                 where the `standard' MIB does not support G.shdsl.bis."


    --
    -- All objects, if implemented, are expected to be implemented to the
    -- maximal level as specified in their OBJECT-TYPE macro.
    --

    ::= { pdnHdsl2ShdslLineCompliances 1 }


-- ==========================
-- == Units of Conformance ==
-- ==========================

pdnHdsl2ShdslLineObjGroups   OBJECT IDENTIFIER ::= { pdnHdsl2ShdslLineGroups 1 }
pdnHdsl2ShdslLineAfnGroups   OBJECT IDENTIFIER ::= { pdnHdsl2ShdslLineGroups 2 }
pdnHdsl2ShdslLineNtfyGroups  OBJECT IDENTIFIER ::= { pdnHdsl2ShdslLineGroups 3 }

-- ===================
-- == Object Groups ==
-- ===================


pdnHdsl2ShdslSpanShdslStatusGroup OBJECT-GROUP
    OBJECTS {
        pdnHdsl2ShdslStatusMaxAttainableLineRate,
        pdnHdsl2ShdslStatusActualLineRate
    }
    STATUS      current
    DESCRIPTION "This group supports objects for retrieving SHDSL-specific
                 span related status."
    ::= { pdnHdsl2ShdslLineObjGroups 1 }

pdnHdsl2ShdslEndpointConfGroup OBJECT-GROUP
    OBJECTS {
        pdnHdsl2ShdslEndpointAlarmConfProfile
    }
    STATUS      current
    DESCRIPTION "This group supports objects for configuring parameters for
                 segment endpoints in SHDSL lines."
    ::= { pdnHdsl2ShdslLineObjGroups 2 }

pdnHdsl2ShdslEndpointCurrGroup OBJECT-GROUP
    OBJECTS {
        pdnHdsl2ShdslEndpointCurrAtn,
        pdnHdsl2ShdslEndpointCurrSnrMgn,
        pdnHdsl2ShdslEndpointCurrStatus,
        pdnHdsl2ShdslEndpointES,
        pdnHdsl2ShdslEndpointSES,
        pdnHdsl2ShdslEndpointCRCanomalies,
        pdnHdsl2ShdslEndpointLOSWS,
        pdnHdsl2ShdslEndpointUAS,
        pdnHdsl2ShdslEndpointCurr15MinTimeElapsed,
        pdnHdsl2ShdslEndpointCurr15MinES,
        pdnHdsl2ShdslEndpointCurr15MinSES,
        pdnHdsl2ShdslEndpointCurr15MinCRCanomalies,
        pdnHdsl2ShdslEndpointCurr15MinLOSWS,
        pdnHdsl2ShdslEndpointCurr15MinUAS,
        pdnHdsl2ShdslEndpointCurr1DayTimeElapsed,
        pdnHdsl2ShdslEndpointCurr1DayES,
        pdnHdsl2ShdslEndpointCurr1DaySES,
        pdnHdsl2ShdslEndpointCurr1DayCRCanomalies,
        pdnHdsl2ShdslEndpointCurr1DayLOSWS,
        pdnHdsl2ShdslEndpointCurr1DayUAS
    }
    STATUS      current
    DESCRIPTION "This group supports objects which provide current status
                 and performance measurements relating to segment endpoints
                 in DSL lines."
    ::= { pdnHdsl2ShdslLineObjGroups 3 }
  

pdnHdsl2Shdsl15MinIntervalGroup OBJECT-GROUP
    OBJECTS {
        pdnHdsl2Shdsl15MinIntervalES,
        pdnHdsl2Shdsl15MinIntervalSES,
        pdnHdsl2Shdsl15MinIntervalCRCanomalies,
        pdnHdsl2Shdsl15MinIntervalLOSWS,
        pdnHdsl2Shdsl15MinIntervalUAS
    }
    STATUS      current
    DESCRIPTION "This group supports objects which maintain historic performance
                 measurements relating to segment endpoints in DSL lines."
    ::= { pdnHdsl2ShdslLineObjGroups 4 }

pdnHdsl2Shdsl1DayIntervalGroup OBJECT-GROUP
    OBJECTS {
        pdnHdsl2Shdsl1DayIntervalMoniSecs,
        pdnHdsl2Shdsl1DayIntervalES,
        pdnHdsl2Shdsl1DayIntervalSES,
        pdnHdsl2Shdsl1DayIntervalCRCanomalies,
        pdnHdsl2Shdsl1DayIntervalLOSWS,
        pdnHdsl2Shdsl1DayIntervalUAS
    }
    STATUS      current
    DESCRIPTION "This group supports objects which maintain historic performance
                 measurements relating to segment endpoints in DSL line in
                 1-day intervals."
    ::= { pdnHdsl2ShdslLineObjGroups 5 }

pdnHdsl2ShdslSpanConfProfileGroup OBJECT-GROUP
    OBJECTS {
        pdnHdsl2ShdslSpanConfWireInterface,
        pdnHdsl2ShdslSpanConfMinLineRate,
        pdnHdsl2ShdslSpanConfMaxLineRate
    }
    STATUS      current
    DESCRIPTION "This group supports objects that constitute configuration
                 profiles for configuring span related parameters in DSL lines."
    ::= { pdnHdsl2ShdslLineObjGroups 6 }

pdnHdsl2ShdslIfTableGroup OBJECT-GROUP
    OBJECTS {
        pdnHdsl2ShdslIfTableEquipMode
    }
    STATUS      current
    DESCRIPTION "This group supports objects on a per-interface basis."
    ::= { pdnHdsl2ShdslLineObjGroups 7 }

pdnHdsl2ShdslExtendedRateModeGroup OBJECT-GROUP
    OBJECTS {
        pdnHdsl2ShdslExtendedRateMode
    }
    STATUS      current
    DESCRIPTION "This group supports objects to select the extended
                 base data rate mode."
    ::= { pdnHdsl2ShdslLineObjGroups 8 }



-- =========================
-- == Notification Groups ==
-- =========================


pdnHdsl2ShdslNotificationGroup NOTIFICATION-GROUP
    NOTIFICATIONS {
        pdnHdsl2ShdslLoopAttenCrossing,
        pdnHdsl2ShdslSNRMarginCrossing,
        pdnHdsl2ShdslPerfESThresh,
        pdnHdsl2ShdslPerfSESThresh,
        pdnHdsl2ShdslPerfCRCanomaliesThresh,
        pdnHdsl2ShdslPerfLOSWSThresh,
        pdnHdsl2ShdslPerfUASThresh,
        pdnHdsl2ShdslpowerBackoff,
        pdnHdsl2ShdsldeviceFault,
        pdnHdsl2ShdsldcContinuityFault,
        pdnHdsl2ShdslconfigInitFailure,
        pdnHdsl2ShdslprotocolInitFailure,
        pdnHdsl2ShdslnoNeighborPresent
    }
    STATUS      current
    DESCRIPTION "This group supports notifications of significant conditions
                 associated with DSL lines."
    ::= { pdnHdsl2ShdslLineNtfyGroups 1 }



-- =========
-- == END ==
-- =========
END