NSCRTV-HFCEMS-ANALOG-MIB DEFINITIONS ::= BEGIN

IMPORTS
     enterprises
          FROM RFC1155-SMI
        DisplayString
        FROM SNMPv2-TC ;
nscrtvRoot  OBJECT IDENTIFIER ::= { enterprises 17409 }

-- DESCRIPTION
--     "NscrtvRoot definition of the National Radio and Television Standardization Technical Committee MIB root nodes"

nscrtvHFCemsTree  OBJECT IDENTIFIER  ::= { nscrtvRoot 1 }

-- DESCRIPTION
--     "NscrtvHFCemsTree definition HFC network equipment management system MIB root nodes,"
--     "All HFC network equipment management system should be in the MIB definition of nodes"

propertyIdent OBJECT IDENTIFIER ::= { nscrtvHFCemsTree 1}

--     DESCRIPTION
--     "Attribute (Property) MIB branch nodes logo"
--     "See Appendix C"

alarmsIdent   OBJECT IDENTIFIER ::= { nscrtvHFCemsTree 2}

--     DESCRIPTION
--     "澯(Alarms)MIBķ֧ڵʶ Alarms MIB branch nodes logo"
--     "See Appendix D"

commonIdent   OBJECT IDENTIFIER ::= { nscrtvHFCemsTree 3}

--     DESCRIPTION
--     "Utility (Common) MIB branch nodes logo"
--     "See Appendix E"

oswIdent OBJECT IDENTIFIER ::= { nscrtvHFCemsTree 15}

--     DESCRIPTION
--     "Optical switch MIB branch node identifier."

--**********************************************************************************************
--                                    analog MIB
--**********************************************************************************************
analogPropertyTable  OBJECT-TYPE
	SYNTAX SEQUENCE OF AnalogPropertyEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION 
		"Simulation parameters attribute table."
	::= { propertyIdent 1 }

analogPropertyEntry  OBJECT-TYPE
	SYNTAX 	AnalogPropertyEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION 
	    "Attribute Table simulation parameters head.OID purpose as a table index, the coding method is 'length + OID.' OID before two members of the '130' is based on '1' and '3' respectively coding, and not ordinary OID encoding (0x2B)."
	INDEX	{ analogParameterOID }
	::= { analogPropertyTable 1 }

AnalogPropertyEntry ::= SEQUENCE {
	analogParameterOID
		OBJECT IDENTIFIER,
	alarmEnable
		OCTET STRING,
	analogAlarmState
		INTEGER,
	analogAlarmHIHI
		INTEGER,
	analogAlarmHI
		INTEGER,
	analogAlarmLO
		INTEGER,
	analogAlarmLOLO
		INTEGER,
	analogAlarmDeadband
		INTEGER
}

analogParameterOID  OBJECT-TYPE
	SYNTAX 	OBJECT IDENTIFIER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION 
		"index"	          

	::= { analogPropertyEntry 1 }

alarmEnable  OBJECT-TYPE
	SYNTAX 	OCTET STRING (SIZE(1))
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION 
		"Alarm enable control byte, the corresponding position for the'1 'that allow alarm,'0' a ban warning
Bit 0: Alarm enable low
Bit 1: Alarm enable low
Bit 2: Alarm enable high
Bit 3: Alarm enable high
Bit 4 ~ 7 reservations should be 0 
This object should be stored in nonvolatile memory."
		
	::= { analogPropertyEntry 2 }

analogAlarmState  OBJECT-TYPE
	SYNTAX 	INTEGER {
		aasNominal (1),
		aasHIHI (2),
		aasHI (3),
		aasLO (4),
		aasLOLO (5)
	}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION 
		"The parameters of the current state of alarm."
	::= { analogPropertyEntry 3 }

analogAlarmHIHI  OBJECT-TYPE
	SYNTAX 	INTEGER 
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION 
		"The parameters of the current state of alarm."
	::= { analogPropertyEntry 4 }

analogAlarmHI  OBJECT-TYPE
	SYNTAX 	INTEGER 
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION 
		"HI high alarm threshold value. This object should be stored in non-volatile memory"
	::= { analogPropertyEntry 5 }

analogAlarmLO  OBJECT-TYPE
	SYNTAX 	INTEGER 
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION 
		"LO low alarm threshold value. This object should be stored in nonvolatile memory"
	::= { analogPropertyEntry 6 }

analogAlarmLOLO  OBJECT-TYPE
	SYNTAX 	INTEGER 
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION 
		"Alarm LOLO very low threshold value. This object should be stored in nonvolatile memory."
	::= { analogPropertyEntry 7 }

analogAlarmDeadband  OBJECT-TYPE
	SYNTAX 	INTEGER
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION 
	"Dead-alarm threshold value. After the warning, parameter values should be restored to the alarm threshold and alarm threshold and the difference between the absolute value greater than the value of dead zone, the alarm can be removed.This object should be stored in nonvolatile memory."
	::= { analogPropertyEntry 8 }

-- *
-- * ɢԱ
-- * ɢԱļ¼ǹ̶ģÿɢͲÿһҪи澯ֵڱ
-- * оӦһ¼ÿɢͲɢԱٶӦһ¼
-- * ɢԱ2һǲʶOIDһɢ澯ֵdiscreteAlarmValue
-- *

discretePropertyTable  OBJECT-TYPE
	SYNTAX SEQUENCE OF DiscretePropertyEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION 
		"Discrete Attribute Table"
	::= { propertyIdent 2 }

discretePropertyEntry  OBJECT-TYPE
	SYNTAX 	DiscretePropertyEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION 
		"Attribute Table discrete head. OID coding methods with simulation attribute table."
	INDEX	{ discreteParameterOID, discreteAlarmValue }
	::= { discretePropertyTable 1 }

DiscretePropertyEntry ::= SEQUENCE {
	discreteParameterOID
		OBJECT IDENTIFIER,
	discreteAlarmValue
		INTEGER,
	discreteAlarmEnable
		INTEGER,
	discreteAlarmState
		INTEGER
}

discreteParameterOID  OBJECT-TYPE
	SYNTAX 	OBJECT IDENTIFIER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION 
		"Attribute Table discrete index 1: Parameters OID"
	::= { discretePropertyEntry 1 }

discreteAlarmValue  OBJECT-TYPE
	SYNTAX 	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION 
		"Attribute Table discrete index 2: parameter values.When the equipment value of this parameter values, and so will be dealt with a warning"
	::= { discretePropertyEntry 2 }


discreteAlarmEnable  OBJECT-TYPE
	SYNTAX 	INTEGER {
		disable (1),
		enableMajor (2),
		enableMinor (3)
	}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION 
		"When the alarm so that it can open the (2 or 3), this parameter allows for alarm processin
If the alarm so that it can shut down (1), alarm processing will be carried out.
This object default values for the disable (1).
This object should be stored in non-volatile memory"
	::= { discretePropertyEntry 3 }

discreteAlarmState  OBJECT-TYPE
	SYNTAX 	INTEGER {
		dasNominal(1),
		dasDiscreteMajor(6),
		dasDiscreteMinor(7)
	}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION 
		"The parameters of the current state of alarm"
	::= { discretePropertyEntry 4 }



currentAlarmTable  OBJECT-TYPE
	SYNTAX SEQUENCE OF CurrentAlarmEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION 
		"The current alarm table."
	::= { propertyIdent 3 }

currentAlarmEntry  OBJECT-TYPE
	SYNTAX 	CurrentAlarmEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION 
		"The current warning Table Head. OID coding methods with simulation attribute table"
	INDEX	{ currentAlarmOID }
	::= { currentAlarmTable 1 }

CurrentAlarmEntry ::= SEQUENCE {
	currentAlarmOID
		OBJECT IDENTIFIER,
	currentAlarmState
		INTEGER,
	currentAlarmValue
		INTEGER
		
}

currentAlarmOID  OBJECT-TYPE
	SYNTAX 	OBJECT IDENTIFIER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION 
		"NE, currently in a state of alarm parameters OID Index, and the alarm in the table attribute parameters OID counterparts."
	::= { currentAlarmEntry 1 }

currentAlarmState  OBJECT-TYPE
	SYNTAX 	INTEGER {
		caasHIHI (2),
		caasHI (3),
		caasLO (4),
		caasLOLO (5),
		caasDiscreteMajor (6),
		caasDiscreteMinor (7)
		
	}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION 
		"Warning parameters of the current state of alarm"
	::= { currentAlarmEntry 2 }
             
currentAlarmValue  OBJECT-TYPE
	SYNTAX 	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION 
		"Alarm parameter values."
	::= { currentAlarmEntry 3 }

--************************************************************************************************
--                                           alarm MIB
--************************************************************************************************
 alarmLogNumberOfEntries OBJECT-TYPE
          SYNTAX INTEGER
          ACCESS read-only
          STATUS mandatory
          DESCRIPTION
"Alarm record number of records in the table"
          ::= { alarmsIdent 1 }

     alarmLogLastIndex OBJECT-TYPE
          SYNTAX INTEGER
          ACCESS read-only
          STATUS mandatory
          DESCRIPTION
              "Recently a warning the index of the records."
          ::= { alarmsIdent 2 }

     alarmLogTable OBJECT-TYPE
          SYNTAX SEQUENCE OF AlarmLogEntry
          ACCESS not-accessible
          STATUS mandatory
          DESCRIPTION
              "Alarm record form, at least support 16 record. Each table in the registration of a new record, the management agent (transponder) managers should send traps news"
          ::= { alarmsIdent 3 }

     alarmLogEntry OBJECT-TYPE
          SYNTAX AlarmLogEntry
          ACCESS not-accessible
          STATUS mandatory
          DESCRIPTION
              "Alarm Sheet Head"
          INDEX { alarmLogIndex }
          ::= { alarmLogTable 1 }

     AlarmLogEntry ::=
          SEQUENCE
          {
               alarmLogIndex
                    INTEGER,
               alarmLogInformation
                    OCTET STRING
          }

     alarmLogIndex OBJECT-TYPE
          SYNTAX INTEGER (1..32767)
          ACCESS read-only
          STATUS mandatory
          DESCRIPTION
"The only logo Alarm Index recorded a record in the table, the index value increased from 1 start of each new record, plus 1 until 32767, under a record index of the re-starts at 1. Acting under the management of storage capacity can be the first choice to delete those records, the specific details in this not to achieve requirements."
          ::= { alarmLogEntry 1 }

     alarmLogInformation OBJECT-TYPE
          SYNTAX OCTET STRING ( SIZE ( 17..255 ) )
          ACCESS read-only
          STATUS mandatory
          DESCRIPTION
               "Alarm record information, multi-byte strings, defined as follows:
Byte 1 ~ 4: Alarm in time (POSIX format, the previous maximum byte)
Byte 5: Alarm types (enumeration, definitions)
Byte 6: Alarm value after commonNeStatus
Byte 7 ~ m: Alarm parameters object identifier (Basic Encoding Rules (ASN.1))
Byte n ~ z: Alarm parameter values (Basic Encoding Rules (ASN.1)) 
Alarm enumerated types:
1 NOMINAL
2 HIHI
3 HI
4 LO
5 LOLO
6 Discrete Major
7 Discrete Minor"
          ::= { alarmLogEntry 2 }  

     alarmText OBJECT-TYPE
          SYNTAX DisplayString
          ACCESS not-accessible
          STATUS optional
          DESCRIPTION
"This trap targets for the needs of information contained in a text field transponder information is achievable.The field contains the text of the object depends on the definition of alarm parameters, it is uncertain, Provisions of this object can not access."

          ::= { alarmsIdent 4 }
         
hfcAlarmEvent TRAP-TYPE
     ENTERPRISE nscrtvHFCemsTree
     VARIABLES { commonPhysAddress, commonNELogicalID, alarmLogInformation, alarmText }
     DESCRIPTION
	"When detected in the event of alarm information sent this trap, whether bundled alarmText variable parameter under warning object to determine. Some of the parameters only need to bind the alarm first three variables"
     ::= 1

--***********************************************************************************************
--				common MIB
--**********************************************************************************************
-- *
-- *  Common MIB
-- *
commonAdminGroup	OBJECT IDENTIFIER ::= { commonIdent 1 }
commonAdminUseRf	OBJECT IDENTIFIER ::= { commonIdent 2 }
commonAdminUseEthernet	OBJECT IDENTIFIER ::= { commonIdent 3 }

commonMACGroup		OBJECT IDENTIFIER ::= { commonAdminUseRf 1 }
commonRfGroup		OBJECT IDENTIFIER ::= { commonAdminUseRf 2 }

commonMacAddress	OBJECT IDENTIFIER ::= { commonMACGroup 1 }
commonBackoffParams	OBJECT IDENTIFIER ::= { commonMACGroup 2 }
commonMacStats		OBJECT IDENTIFIER ::= { commonMACGroup 3 }

commonAgentGroup	OBJECT IDENTIFIER ::= { commonAdminUseEthernet 1 }
commonDeviceGroup	OBJECT IDENTIFIER ::= { commonAdminUseEthernet 2 }

-- *************
-- *   NE
-- *************

commonNELogicalID  OBJECT-TYPE
     SYNTAX OCTET STRING (SIZE(0..40))
     ACCESS read-write
     STATUS mandatory
     DESCRIPTION 
	"The logic of the designated NE identifier (LogicID), the values and attributes of other unrelated NE.This target value should be stored in non-volatile memory"
     ::= { commonAdminGroup 1 }

commonNEVendor  OBJECT-TYPE
     SYNTAX DisplayString (SIZE(0..255))
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION 
	"NE equipment manufacturers"
     ::= { commonAdminGroup 2 }

commonNEModelNumber  OBJECT-TYPE
     SYNTAX DisplayString (SIZE(0..255))
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION 
""
     ::= { commonAdminGroup 3 }

commonNESerialNumber  OBJECT-TYPE
     SYNTAX DisplayString (SIZE(0..255))
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION 
	"NE equipment serial numbers"
     ::= { commonAdminGroup 4 }

commonNEVendorInfo  OBJECT-TYPE
     SYNTAX DisplayString (SIZE(0..255))
     ACCESS read-only
     STATUS optional
     DESCRIPTION 
	"NE equipment suppliers other special designated information"
     ::= { commonAdminGroup 5 }

commonNEStatus  OBJECT-TYPE						
     SYNTAX OCTET STRING (SIZE(1))
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION 
	"With 7.5.4 STATRESP PDU in the corresponding parameters Status
Bit 0: CHNLRQST
Bit 1: CNTNRM
Bit 2: CNTCUR
Bit 3: MAJOR ALARMS
Bit 4: MINOR ALARMS
Bit 5: RSVD1
Bit 6: RSVD2 
Bit 7: RSVD3"
     ::= { commonAdminGroup 6 }

commonReset  OBJECT-TYPE							
     SYNTAX INTEGER { reset (1) }
     ACCESS read-write
     STATUS mandatory
     DESCRIPTION 
     	"Write'1 'will be reset NE equipment, the value will be included in other non-functional. Reading this object return value'1 ', the equipment had no effect"
     ::= { commonAdminGroup 7 }

commonAlarmDetectionControl OBJECT-TYPE
     SYNTAX INTEGER {
        detectionDisabled (1),
        detectionEnabled (2),
        detectionEnabledAndRegenerate (3)
     }
ACCESS read-write
    STATUS mandatory
    DESCRIPTION 
        "This object used to control the Alarm Detection NE.When the attribute table or discrete simulation attribute table MIB objects to a set threshold, that alarm has occurred and, as recorded in the latest warning alarm Sheet (alarmLogTable) add one warning traps will also produce. 
If the value of a MIB object is not normal, and the current alarm in the table (currentAlarmTable) will also add a record.DetectionDisabled (1) will stop and simulation Attribute Table / Attribute Table associated discrete alarm detection process, NE will no longer have a warning. 
DetectionEnabled (2) allow the alarm detection, detection from detectionEnabled be set in which the transponder before beginning continue. DetectionEnabledAndRegenerate (3) removal of all information and allow Warning Alarm Detection conducted.
Attribute Table and discrete simulation attribute table of all alarm attributes will be returned to the alarm before the normal operation of the. 
Any still in a state of alarm attributes will not have a 'return to normal' warning, set this value will remove warning and the current record sheet alarmLogTable Alarm Table currentAlarmTable content.
DetectionEnabledAndRegenerate role is temporary, as will be set to detectionEnabledAndRegnerate commonAlarmDetectionControl after its SNMP response includes this value, if read beyond this target value, the response to detectionEnabled.DetectionDisabled hfcColdStart or value does not affect the selection of hfcWarmStart traps.Future additional traps in its description unless there are specific provisions in Otherwise they would be free from the impact of this object.
This object should be stored in nonvolatile memory, the default values for detectionEnabled" 
     ::= { commonAdminGroup 8 }

commonNetworkAddress  OBJECT-TYPE
     SYNTAX NetworkAddress
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION 
	"NE network IP address, NE produce Trap should include this address. This value should be stored in nonvolatile memory. This value can be registered through the MAC order or through the local interface vendors to set up."
     ::= { commonAdminGroup 9 }


commonCheckCode  OBJECT-TYPE                    
     SYNTAX INTEGER
     ACCESS read-write
     STATUS mandatory
     DESCRIPTION 
"This target for the detection transponder code configuration of the report. The calculation includes detection code transponder (including management equipment) and the physical configuration parameters stored in non-volatile memory of all the parameters. The detection algorithm calculated by the vendor code provisions. 
The object should be kept in the value of non-volatile memory, the response thinks highly activated, will be recalculated and re-testing code and the value prior to the commencement of comparison to determine whether or should haveһhfcColdStart hfcWarmStart traps. 
When write this object (SetRequest), the detection code will be recalculated and fill the SetRequest in response to the GetResponse. At this time, will not produce hfcColdStart or hfcWarmStart traps."
     ::= { commonAdminGroup 10 }

commonTrapCommunityString  OBJECT-TYPE
     SYNTAX OCTET STRING (SIZE(0..64))
     ACCESS read-write
     STATUS mandatory
     DESCRIPTION   
"Definition of Community Trap string. The default value is' public '"
     ::= { commonAdminGroup 11 }

commonTamperStatus  OBJECT-TYPE
     SYNTAX INTEGER { intact (1), compromised (2) }
     ACCESS read-only
     STATUS optional
     DESCRIPTION 
"The safety report NE switching equipment (such as whether to open up the lid) state that this object is called discrete attributes of a corresponding entry in the table. Intact that normal, compromised expressed alarm"
     ::= { commonAdminGroup 12 }

commonInternalTemperature  OBJECT-TYPE
     SYNTAX INTEGER (-128..127)
     ACCESS read-only
     STATUS optional
     DESCRIPTION 
"NE equipment Room (machine) temperature, units degrees Celsius. This request object attribute in a corresponding entry in the table"
     ::= { commonAdminGroup 13 }

commonTime  OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-write
     STATUS optional
     DESCRIPTION 
	"NE of the POSIX said that the current time (since at 0:00 on January 1, 1970 since the seconds)."
     ::= { commonAdminGroup 14 }

commonVarBindings  OBJECT-TYPE                        
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION 
"This object can be said to receive SNMP information NE variables bundled the largest number of tables. Value: 0 indicated no restrictions on the maximum number bundled"
     ::= { commonAdminGroup 15 }

commonResetCause  OBJECT-TYPE
     SYNTAX INTEGER {
          other (1),
          powerup (2),
          command (3),
          watchdog (4),
          craft (5)
     }
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION 
"NE said the reasons for the recent reduction."
     ::= { commonAdminGroup 16 }

commonCraftStatus  OBJECT-TYPE
     SYNTAX INTEGER {
          disconnected (1),
          connected (2)
     }
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION 
"NE local object that this interface (such as RS232 or RS485 interface) state. NE does not necessarily have to support the local interface. NE local interface without affecting the state of its MAC interface functions; If we do not support the local interface, and its value is disconnected."
     ::= { commonAdminGroup 17 }

commonDeviceOID OBJECT-TYPE                   
     SYNTAX OBJECT IDENTIFIER
     ACCESS read-only
     STATUS optional
     DESCRIPTION 
"This OID object as a pointer, the equipment was used at MIB (such as Node, two-way amplifier, etc.). "
     ::= { commonAdminGroup 18 }

commonDeviceId OBJECT-TYPE
     SYNTAX OCTET STRING (SIZE(32))
     ACCESS read-only
     STATUS optional
     DESCRIPTION
"The contents of this object by the designated by the equipment vendors, manufacturers and products it contains special ASCII text messages"
     ::= { commonAdminGroup 19 }



-- ****************
-- *   NE PhysAddress
-- ****************

commonPhysAddress  OBJECT-TYPE
     SYNTAX OCTET STRING
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION 
"NE physical address"
     ::= { commonMacAddress 1 }

commonMaxMulticastAddresses  OBJECT-TYPE
     SYNTAX INTEGER (4..255)
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION 
"NE equipment to support the greatest number of multicast addresses."
     ::= { commonMacAddress 2 }

commonMulticastAddressTable  OBJECT-TYPE
     SYNTAX SEQUENCE OF CommonMulticastAddressEntry
     ACCESS not-accessible
     STATUS mandatory
     DESCRIPTION 
"Multicast addresses Table, the value of this object should be stored in nonvolatile memory."
     ::= { commonMacAddress 3 }

commonMulticastAddressEntry  OBJECT-TYPE
     SYNTAX CommonMulticastAddressEntry
     ACCESS not-accessible
     STATUS mandatory
     DESCRIPTION 
"Multicast addresses head table."
     INDEX { commonMulticastAddressIndex }
     ::= { commonMulticastAddressTable 1 }

CommonMulticastAddressEntry ::=
     SEQUENCE
     {
          commonMulticastAddressIndex
               INTEGER,
          commonMulticastAddressNumber
               OCTET STRING
     }

commonMulticastAddressIndex  OBJECT-TYPE
     SYNTAX INTEGER (1..255)
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION 
"Multicast addresses head table."
     ::= { commonMulticastAddressEntry 1 }

commonMulticastAddressNumber  OBJECT-TYPE
     SYNTAX OCTET STRING (SIZE(6))
     ACCESS read-write
     STATUS mandatory
     DESCRIPTION 
"Multicast address, I / G-1 effective."
     ::= { commonMulticastAddressEntry 2 }


commonBackoffPeriod  OBJECT-TYPE
     SYNTAX INTEGER (0..16383)
     ACCESS read-write
     STATUS mandatory
     DESCRIPTION 
"Backoff algorithm benchmark time (ms), initialize the default value of 6 ms.The value of this object should be stored in nonvolatile memory."
     ::= { commonBackoffParams 1 }

commonACKTimeoutWindow  OBJECT-TYPE
     SYNTAX INTEGER (0..255)
     ACCESS read-write
     STATUS mandatory
     DESCRIPTION 
"NE awaiting HE overtime to send ACK response time (ms), initialize the default value is 19 ms.The value of this object should be stored in nonvolatile memory."
     ::= { commonBackoffParams 2 }

commonMaximumMACLayerRetries  OBJECT-TYPE              
     SYNTAX INTEGER (0..255)
     ACCESS read-write
     STATUS mandatory
     DESCRIPTION 
"NE data packets sent the greatest number of re-examination. Initialize the default value is 16.The value of this object should be stored in nonvolatile memory."
     ::= { commonBackoffParams 3 }

commonMaxPayloadSize  OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION 
"From top to bottom line channel packet supported by the largest payload (payload) the length of"
     ::= { commonBackoffParams 4 }

commonBackoffMinimumExponent  OBJECT-TYPE
     SYNTAX INTEGER (0..15)
     ACCESS read-write
     STATUS mandatory
     DESCRIPTION 
"The standards body of the MAC layer specification definition of the smallest backoff algorithm index value, default values for 6.This value may not exceed commonBackoffMaximumValue value.The value of this object should be stored in nonvolatile memory."
     ::= { commonBackoffParams 5 }

commonBackoffMaximumExponent  OBJECT-TYPE
     SYNTAX INTEGER (0..15)
     ACCESS read-write
     STATUS mandatory
     DESCRIPTION 
"The body of the MAC layer standard definition of backoff algorithm for standardizing the largest index value, the default value is 15.This value shall be not less than commonBackoffMinimum value.The value of this object should be stored in nonvolatile memory."
     ::= { commonBackoffParams 6 }


commonForwardPathLOSEvents  OBJECT-TYPE
     SYNTAX Counter
     ACCESS read-write
     STATUS optional
     DESCRIPTION 
"LOS downlink channel in the number of reset to 0."
     ::= { commonMacStats 1 }

commonForwardPathFramingErrors  OBJECT-TYPE
     SYNTAX Counter
     ACCESS read-write
     STATUS optional
     DESCRIPTION 
"Downlink Channel frames wrong number reset to 0."
     ::= { commonMacStats 2 }

commonForwardPathCRCErrors  OBJECT-TYPE
     SYNTAX Counter
     ACCESS read-write
     STATUS optional
     DESCRIPTION 
"CRC errors down the number of reset to 0."
     ::= { commonMacStats 3 }

commonInvalidMacCmds  OBJECT-TYPE
     SYNTAX Counter
     ACCESS read-write
     STATUS optional
     DESCRIPTION 
"Invalid MAC layer order wrong number reset to 0."
     ::= { commonMacStats 4 }

commonBackwardPathCollisionTimes OBJECT-TYPE
     SYNTAX Counter
     ACCESS read-write
     STATUS optional
     DESCRIPTION 
"Uplink Packet collision frequency, reset to 0."
     ::= { commonMacStats 5 }


                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    
commonReturnPathFrequency  OBJECT-TYPE
     SYNTAX INTEGER (0..1000000000)
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION 
"Channel uplink frequency units Hz.The value of this object should be stored in non-volatile memory"
     ::= { commonRfGroup 1 }

commonForwardPathFrequency  OBJECT-TYPE
     SYNTAX INTEGER (0..1000000000)
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION 
"Downlink frequency channel, flat Hz.The value of this object should be stored in nonvolatile memory."
     ::= { commonRfGroup 2 }

commonProvisionedReturnPowerLevel  OBJECT-TYPE                 
     SYNTAX INTEGER (0..127)
     ACCESS read-write
     STATUS mandatory
     DESCRIPTION 
"Upstream channel power levels and units for dBuV.When the internal use of this value will be rounded to the nearest support value. Reading return to this subject when the actual value rather than rounding value.The value of this object should be stored in nonvolatile memory."          
     ::= { commonRfGroup 3 }

commonForwardPathReceiveLevel  OBJECT-TYPE
     SYNTAX INTEGER (0..127)
     ACCESS read-only
     STATUS optional
     DESCRIPTION 
"Downlink Channel receive power levels, units dBuV."
     ::= { commonRfGroup 4 }

commonMaxReturnPower  OBJECT-TYPE
     SYNTAX INTEGER (0..127)
     ACCESS read-write
     STATUS mandatory
     DESCRIPTION 
"The largest upstream channel power levels and units for dBuV.The value of this object should be stored in nonvolatile memory."
     ::= { commonRfGroup 5 }


commonAgentBootWay  OBJECT-TYPE
	SYNTAX  INTEGER {
		bootDefault (1),
		bootBOOTP (2),
		bootTFTP (3)
	}
	ACCESS     read-write
	STATUS     mandatory
	DESCRIPTION 
		""
	::= { commonAgentGroup 1 }

commonAgentReset  OBJECT-TYPE
	SYNTAX     INTEGER { reset(1) }
	ACCESS     read-write
	STATUS     mandatory
	DESCRIPTION 
	"Acting Restart, write'1 'will enable agents to restart, the value will be included in other non-functional. Reading this object return value'1 ', the agent had no effect"
	::= { commonAgentGroup 2 }

commonAgentMaxTraps  OBJECT-TYPE
	SYNTAX     INTEGER
	ACCESS     read-write
	STATUS     mandatory
	DESCRIPTION 
		"Acting detected alarm when sent to the management of the largest number of TRAP, 0 that manufacturers use the default default values"
	::= { commonAgentGroup 3 }

commonAgentTrapMinInterval  OBJECT-TYPE
	SYNTAX     INTEGER
	ACCESS     read-write
	STATUS     mandatory
	DESCRIPTION 
		"Acting TRAP send the minimum spacing units"
	::= { commonAgentGroup 4 }

commonAgentTrapMaxInterval  OBJECT-TYPE
	SYNTAX     INTEGER
	ACCESS     read-write
	STATUS     mandatory
	DESCRIPTION 
		"Acting TRAP send the largest spacing units for"
	::= { commonAgentGroup 5 }

commonTrapAck  OBJECT-TYPE							
     SYNTAX OCTET STRING ( SIZE ( 17..255 ) )
     ACCESS read-write
     STATUS optional
     DESCRIPTION 
     	"The variables used to notify Snmp agents, it issued the warning Trap has received information management console, do not have to re-hair. The content of the variables in alarmLogInformation MIB and the same warning. Agents received after the adoption of alarmLogInformation management can clearly know the host response is a warning which Trap information, thereby stop the alarm Trap weight of the information."
     ::= { commonAgentGroup 6 }

commonAgentTrapTable  OBJECT-TYPE
	SYNTAX SEQUENCE OF CommonAgentTrapEntry
	ACCESS     not-accessible
	STATUS     mandatory
	DESCRIPTION 
		"Acting Information Table TRAP"
	::= { commonAgentGroup 7 }

commonAgentTrapEntry  OBJECT-TYPE
	SYNTAX 	CommonAgentTrapEntry
	ACCESS     not-accessible
	STATUS     mandatory
	DESCRIPTION 
		"Acting Head TRAP Information Table"
	INDEX { commonAgentTrapIndex }
	::= { commonAgentTrapTable 1 }

CommonAgentTrapEntry ::= SEQUENCE {
	commonAgentTrapIndex
		INTEGER,
	commonAgentTrapIP
		IpAddress,
	commonAgentTrapCommunity
		DisplayString,
	commonAgentTrapStatus
		INTEGER
}

commonAgentTrapIndex  OBJECT-TYPE
	SYNTAX     INTEGER
	ACCESS     read-only
	STATUS     mandatory
	DESCRIPTION 
		"TRAP Table Index"
	::= { commonAgentTrapEntry 1 }

commonAgentTrapIP  OBJECT-TYPE
	SYNTAX     IpAddress
	ACCESS     read-write
	STATUS     mandatory
	DESCRIPTION 
		"When the purpose of the TRAP host's IP address"
	::= { commonAgentTrapEntry 2 }

commonAgentTrapCommunity  OBJECT-TYPE
	SYNTAX     DisplayString (SIZE(0..64))
	ACCESS     read-write
	STATUS     mandatory
	DESCRIPTION 
		"Send the Community string TRAP"
	::= { commonAgentTrapEntry 3 }

commonAgentTrapStatus  OBJECT-TYPE
	SYNTAX     INTEGER {
		commonAgentTrapEnable (1),
		commonAgentTrapDisable (2)
	}
	ACCESS     read-write
	STATUS     mandatory
	DESCRIPTION 
		"It said that the opening of TRAP"
	::= { commonAgentTrapEntry 4 }


commonDeviceNum  OBJECT-TYPE
	SYNTAX     INTEGER
	ACCESS     read-write
	STATUS     mandatory
	DESCRIPTION 
		"The agent said that the current management is the number of devices"
	::= { commonDeviceGroup 1 }
	
commonDeviceInfoTable  OBJECT-TYPE
	SYNTAX SEQUENCE OF CommonDeviceInfoEntry
	ACCESS     not-accessible
	STATUS     mandatory
	DESCRIPTION 
		"Acting is currently public information management equipment list."
	::= { commonDeviceGroup 2 }

commonDeviceInfoEntry  OBJECT-TYPE
	SYNTAX 	CommonDeviceInfoEntry
	ACCESS     not-accessible
	STATUS     mandatory
	DESCRIPTION 
		"Acting is currently public information management equipment list Table Head."
	INDEX { commonDeviceSlot }
	::= { commonDeviceInfoTable 1 }

CommonDeviceInfoEntry ::= SEQUENCE {
	commonDeviceSlot
		INTEGER,
	commonDevicesID
		OCTET STRING,
	commonDeviceVendor
		DisplayString,
	commonDeviceModelNumber
		DisplayString,
	commonDeviceSerialNumber
		DisplayString,
	commonDeviceVendorInfo
		DisplayString,
	commonDeviceStatus
		OCTET STRING,
	commonDeviceReset
		INTEGER,
	commonDeviceAlarmDetectionControl
		INTEGER,
	commonDeviceMACAddress
		NetworkAddress,
	commonDeviceTamperStatus
		INTEGER,
	commonDeviceInternalTemperature
		INTEGER,
	commonDeviceResetCause
		INTEGER,
	commonDeviceCraftStatus
		INTEGER,
	commonDevicesOID
		OBJECT IDENTIFIER,
	commonDeviceAcct
		Counter,
	commonDeviceName
		DisplayString,
	commonDeviceMFD
		DisplayString,
	commonDeviceFW
		DisplayString
}

commonDeviceSlot  OBJECT-TYPE
	SYNTAX 	INTEGER
	ACCESS  read-only
	STATUS 	mandatory
	DESCRIPTION 
		"Acting is currently under the management of the equipment list of public information table index."
	::= { commonDeviceInfoEntry 1 }

commonDevicesID  OBJECT-TYPE
	SYNTAX 	OCTET STRING (SIZE(0..40))
	ACCESS  read-only
	STATUS 	mandatory
	DESCRIPTION 
		"Designated equipment manufacturers logo"
	::= { commonDeviceInfoEntry 2 }
	
commonDeviceVendor  OBJECT-TYPE
     SYNTAX DisplayString (SIZE(0..255))
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION 
"Equipment manufacturers"
	::= { commonDeviceInfoEntry 3 }

commonDeviceModelNumber  OBJECT-TYPE
     SYNTAX DisplayString (SIZE(0..255))
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION 
	     "Equipment models."
	
	::= { commonDeviceInfoEntry 4 }

commonDeviceSerialNumber  OBJECT-TYPE
     SYNTAX DisplayString (SIZE(0..255))
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION 
	     "The string of equipment."
	::= { commonDeviceInfoEntry 5 }

commonDeviceVendorInfo  OBJECT-TYPE
     SYNTAX DisplayString (SIZE(0..255))
     ACCESS read-only
     STATUS optional
     DESCRIPTION 
	    "Equipment suppliers of other special designated information"
	::= { commonDeviceInfoEntry 6 }

commonDeviceStatus  OBJECT-TYPE						
     SYNTAX OCTET STRING (SIZE(1))
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION 
"
           Bit 0: RSVD0
           Bit 1: RSVD1
           Bit 2: RSVD2
           Bit 3: MAJOR ALARMS
           Bit 4: MINOR ALARMS
           Bit 5: RSVD5
           Bit 6: RSVD6
		   Bit 7: RSVD7"
	::= { commonDeviceInfoEntry 7 }

commonDeviceReset  OBJECT-TYPE							
     SYNTAX INTEGER { reset (1) }
     ACCESS read-write
     STATUS mandatory
     DESCRIPTION 
"Write'1 'will be reset equipment, other values will be written into the non-functional. Reading this object return value'1 ', the equipment had no effect."
	::= { commonDeviceInfoEntry 8 }

commonDeviceAlarmDetectionControl OBJECT-TYPE
     SYNTAX INTEGER {
        detectionDisabled (1),
        detectionEnabled (2),
        detectionEnabledAndRegenerate (3)
     }
     ACCESS read-write
     STATUS mandatory
     DESCRIPTION 
"This object used to control equipment alarm detection. "
	::= { commonDeviceInfoEntry 9 }
	
commonDeviceMACAddress  OBJECT-TYPE
	SYNTAX 	NetworkAddress
	ACCESS  read-only
	STATUS 	mandatory
	DESCRIPTION 
"Equipment MAC address"
	::= { commonDeviceInfoEntry 10 }

commonDeviceTamperStatus OBJECT-TYPE
     SYNTAX INTEGER { intact (1), compromised (2) }
     ACCESS read-only
     STATUS optional
     DESCRIPTION 
"Report of the safety switch equipment (such as whether to open up the lid) state that this object is called discrete attributes of a corresponding entry in the table. Intact that normal, compromised expressed alarm."
	::= { commonDeviceInfoEntry 11 }
	
commonDeviceInternalTemperature OBJECT-TYPE
     SYNTAX INTEGER (-128..127)
     ACCESS read-only
     STATUS optional
     DESCRIPTION 
"Equipment Room (machine) temperature, units degrees Celsius. This request object attribute in a corresponding entry in the table"
	::= { commonDeviceInfoEntry 12 }
	
commonDeviceResetCause OBJECT-TYPE
     SYNTAX INTEGER {
          other (1),
          powerup (2),
          command (3),
          watchdog (4),
          craft (5)
     }
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION 
"Equipment that the reasons for the recent reduction"
	::= { commonDeviceInfoEntry 13 }
	
commonDeviceCraftStatus OBJECT-TYPE
     SYNTAX INTEGER {
          disconnected (1),
          connected (2)
     }
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION 
"This object interface that local equipment (such as RS232 or RS485 interface) state."
	::= { commonDeviceInfoEntry 14 }
	
commonDevicesOID OBJECT-TYPE
     SYNTAX  OBJECT IDENTIFIER
     ACCESS  read-only
     STATUS  mandatory
     DESCRIPTION
"Goals identifier string, point to a concrete realization of the equipment"
	::= { commonDeviceInfoEntry 15 }

commonDeviceAcct OBJECT-TYPE
     SYNTAX  Counter
     ACCESS  read-only
     STATUS  optional
     DESCRIPTION
"Equipment that the accumulated work time, units of s"
	::= { commonDeviceInfoEntry 16 }
	
commonDeviceName OBJECT-TYPE
     SYNTAX DisplayString (SIZE(0..255))
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION 
"Equipment name"
	::= { commonDeviceInfoEntry 17 }
	
commonDeviceMFD OBJECT-TYPE
     SYNTAX DisplayString (SIZE(10))
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION 
"Equipment manufacturing date."
	::= { commonDeviceInfoEntry 18 }
	
commonDeviceFW OBJECT-TYPE
     SYNTAX DisplayString (SIZE(0..255))
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION 
"Equipment firmware information"
	::= { commonDeviceInfoEntry 19 }





hfcColdStart  TRAP-TYPE
     ENTERPRISE nscrtvHFCemsTree
     VARIABLES { commonPhysAddress, commonNELogicalID}
     DESCRIPTION 
"HfcColdStart traps that are sent to re-initialization protocol entities, and entities agent configuration or agreement may have changed. This trap only after the success of transponder sent registration"
     ::= 0

hfcWarmStart  TRAP-TYPE
     ENTERPRISE nscrtvHFCemsTree
     VARIABLES {  commonPhysAddress, commonNELogicalID }
     DESCRIPTION 
"HfcWarmStart traps that are sent to re-initialization protocol entities, and entities agent configuration or agreement has not changed. This trap only after the completion of transponder sent registration"

     ::= 2


--*********************************************************************************************
--					Optical Switch MIB
--*********************************************************************************************
oswVendorOID OBJECT-TYPE
     SYNTAX OBJECT IDENTIFIER
     ACCESS read-only
     STATUS optional
     DESCRIPTION 
        "This object provides manufacturers of optical switch MIB expansion. Without the expansion, this should be targeting at the optical switch nodes oswIdent"
     ::= { oswIdent 1 }
oswMode OBJECT-TYPE	
     SYNTAX INTEGER ( 0..3 )
     ACCESS read-write
     STATUS mandatory
     DESCRIPTION
          "The work modes of the optical switch:'1' indicates the switch choose route B'2' indicates the switch choose route A'3' indicates the switch choose any one output route"
     ::= { oswIdent 2 }

oswSwitch OBJECT-TYPE
     SYNTAX INTEGER ( 0..65535 )
     ACCESS read-write
     STATUS mandatory
     DESCRIPTION
          "Optical switch breaking point"
     ::= { oswIdent 3 }

    -- ****************
    -- * ͨ
    -- ****************
oswChannelTable OBJECT-TYPE
     SYNTAX SEQUENCE OF OswChannelEntry
     ACCESS not-accessible
     STATUS mandatory
     DESCRIPTION
          "Optical Switch Information Table"
     ::= { oswIdent 4 }

oswChannelEntry OBJECT-TYPE
     SYNTAX OswChannelEntry
     ACCESS not-accessible
     STATUS mandatory
     DESCRIPTION
          "Optical Switch Information Table Head"
     INDEX { oswIndex }
     ::= { oswChannelTable 1 }

OswChannelEntry ::=
     SEQUENCE
     {
          oswUnitTemp
               INTEGER,
          oswInputA
               INTEGER,
          oswInputB          
               INTEGER,
          oswOutput1
               INTEGER,
          oswOutput2
               INTEGER
     }

oswUnitTemp OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
          "Chassis temperature of the Optical switch, unit in 1 centigrade degree."
     ::= { oswChannelEntry 1 }

oswInputA OBJECT-TYPE
     SYNTAX INTEGER ( -128..127 )
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
          "The input optical power of route A, unit in 0.1 dBm, this object require entry register in the attribute MIB."
     ::= { oswChannelEntry 2 }
     
oswInputB OBJECT-TYPE
     SYNTAX INTEGER ( -128..127 )
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
          "The input optical power of route B, unit in 0.1 dBm, this object require entry register in the attribute MIB."
     ::= { oswChannelEntry 3 }

oswOutput1 OBJECT-TYPE
     SYNTAX INTEGER ( 0..65535 )
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
          "The input optical power of route 1, unit in 0.1 dBm, this object require entry register in the attribute MIB."
     ::= { oswChannelEntry 4 }

oswOutput2 OBJECT-TYPE
     SYNTAX INTEGER ( 0..65535 )
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
          "The input optical power of route 2, unit in 0.1 dBm, this object require entry register in the attribute MIB."
     ::= { oswChannelEntry 5 }


-- *****************
-- * ֱԴ
-- *****************

oswNumberDCPowerSupply OBJECT-TYPE
     SYNTAX INTEGER ( 0..16 )
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
	     "The number of internal DC power supply,'0 'indicates the transponder nonsupport this function."
     ::= { oswIdent 5 }

oswDCPowerSupplyMode OBJECT-TYPE
     SYNTAX INTEGER { loadsharing(1), switchedRedundant(2), aloneSupply(3)}
     ACCESS read-only
     STATUS optional
     DESCRIPTION
"Power supply work modes: Load and load-sharing, standby switch, or independency power supply. If the equipment has only one DC power supply, this should not be supported."
     ::= { oswIdent 6 }

oswDCPowerTable OBJECT-TYPE
     SYNTAX SEQUENCE OF OswDCPowerEntry
     ACCESS not-accessible
     STATUS mandatory
     DESCRIPTION
 	     "DC Power Information Table"
     ::= { oswIdent 7 }

oswDCPowerEntry OBJECT-TYPE
     SYNTAX OswDCPowerEntry
     ACCESS not-accessible
     STATUS mandatory
     DESCRIPTION
	     "DC Power Information Table Head"
     INDEX { oswDCPowerIndex }
     ::= { oswDCPowerTable 1 }

OswDCPowerEntry ::=SEQUENCE
     {
          oswDCPowerIndex
               INTEGER,
          oswDCPowerVoltage
               INTEGER,
          oswDCPowerCurrent
               INTEGER,
          oswDCPowerName
               DisplayString
     }

oswDCPowerIndex OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "DC Power Index, table oswDCPowerTable index"
     ::= { oswDCPowerEntry 1 }

oswDCPowerVoltage OBJECT-TYPE
     SYNTAX INTEGER ( -32768..32767 )
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
 	     "Power supply voltage, unit in 0.1 V, this object require entry register in the attribute MIB."
     ::= { oswDCPowerEntry 2 }

oswDCPowerCurrent OBJECT-TYPE
     SYNTAX INTEGER ( 0..65535 )
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
 	       "Power supply current, unit in 0.1 A, this object require entry register in the attribute MIB."
     ::= { oswDCPowerEntry 3 }

oswDCPowerName OBJECT-TYPE
     SYNTAX DisplayString
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
"Mark Power supply name, for example: +5 V DC power supply.
This field value regulated by the user, it should be marked with the number of the power supply voltage and distinguish the multi-power supplies at least.
When the object in this table give an alarm, the name of this object should be put into the alarmText target in the hfcAlarmEvent trap.
"
     ::= { oswDCPowerEntry 4 }


END