   NORTEL-OME40G-FAC-MIB DEFINITIONS ::= BEGIN

   IMPORTS
       nnOme40G            FROM NORTEL-OME40G-MIB
       DisplayString       FROM RFC1213-MIB
       RowStatus           FROM SNMPv2-TC
       ifIndex             FROM IF-MIB


       MODULE-IDENTITY,
       OBJECT-TYPE,
       OBJECT-IDENTITY   FROM SNMPv2-SMI;

nnOme40GFacilities MODULE-IDENTITY
        LAST-UPDATED "201408180000Z"
        ORGANIZATION "Nortel"
        CONTACT-INFO
           "   7035 Ridge Road
               Hanover, Maryland 21076
               United States
               Toll-free: +1-800-921-1144
               Phone: +1-410-694-5700
               Fax: +1-410-694-5750
               www.ciena.com "
        DESCRIPTION
              "Optical Multiservice Edge (ome)
              This Module will be used to identify the facility attributes for
              Nortel OME6500 40G facilities"
   
        --Revision history
        REVISION "200708100000Z"
        DESCRIPTION "Initial Version - created for OME6500 REL 5.1" 
        
        REVISION "200905200000Z"
        DESCRIPTION 
	        "String length were changed from 32 to 64 for the following attributes:
	         otuTxTTI,oduTxTTI, otuRxExpTTI,oduRxExpTTI in  OME6500 REL 6.0"  

        REVISION "201408180000Z"
        DESCRIPTION 
	        "Added new enums gfp-mactr192(5), gfp-std192(6), gfp-mactr64(7), gfp-std64(8),
                gfp-macostr(9), gfp-macostr192(10), gfp-macostr64(11), ull(12)for ethMapping 
                in OME6500 REL 10.1"
              
	::= { nnOme40G 1 }

nnOCn        OBJECT IDENTIFIER ::= { nnOme40GFacilities 1 }
nnOTMn       OBJECT IDENTIFIER ::= { nnOme40GFacilities 2 }
nnEth        OBJECT IDENTIFIER ::= { nnOme40GFacilities 3 }
nnWAN        OBJECT IDENTIFIER ::= { nnOme40GFacilities 4 }


GccValues ::= INTEGER {
	    unknown(0),
        none(1),
		gcc0(2),
		gcc1(3),
		gcc2(4)
}


-- The Admin State and Primary States 
-- are doubly defined in the 40G Fac
-- module and the OME6500 Equipment
-- module. Ultimately, they need to 
-- be merged. In the meantime, they
-- need to be concurrently updated.
AdminState ::= INTEGER  {
    unknown(0),
    is(1),
    oos(2)
}

PrimaryState ::= INTEGER {
    unknown(0),
    is(1),
    is-anr(2),
    oos-au(3),
    oos-ma(4),
    oos-auma(5),
    oos-maanr(6)
}

LoopbackType ::= INTEGER {
    unknown(0),
    none(1),
    facility(2),
    terminal(3),
    efmremote(4)
}

Status ::= INTEGER {
    unknown(0),
    enabled(1),
    disabled(2)
}

FecFormat ::= INTEGER {
    unknown(0),
    off(1),
    rs8(2),
    scfec(3),
    bch20(4),
    pfec(5)
}


nnOCnTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF NnOCnEntry
	MAX-ACCESS  not-accessible
	STATUS  current
	DESCRIPTION  "Contains entries for OC192 and OC768 facilities"
	::= { nnOCn 1 }

nnOCnEntry OBJECT-TYPE
	SYNTAX NnOCnEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION "This entry shall contain all the necessary attributes
                     for the OC768 and OC192 facilities in the 40G card"
	INDEX { ifIndex }
    ::= { nnOCnTable 1 }

NnOCnEntry ::= 
    SEQUENCE {
		ocnRowStatus
			RowStatus,
		stFormat
			INTEGER,
		expSTrc
			DisplayString,
		stfMode
			INTEGER,
		eBerTh
			Integer32,
		ocnPortMode
			INTEGER,
		ocnLaserOffFarEndFail
			Status,
		oChTxActOcnPwr
			DisplayString,
		oChTxMinOcnPwr
			DisplayString,
		oChTxMaxOcnPwr
			DisplayString,
		oChRxActOcnPwr
			DisplayString,
		oChRxMinOcnPwr
			DisplayString,
		oChRxMaxOcnPwr
			DisplayString,
		expSectionTraceMsg
			DisplayString,
		incSectionTraceMsg
			DisplayString,
		ocnLoopbackType
			LoopbackType,
		ocnPrimaryState
			PrimaryState,
		ocnSecondaryState
			DisplayString,
		ocnAdminState
			AdminState,
		ocnAID
			DisplayString
	}


ocnRowStatus OBJECT-TYPE
	SYNTAX RowStatus
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "This attribute is used to manage rows in the 
	             facility entry"
	::= { nnOCnEntry 1 }

stFormat OBJECT-TYPE
	SYNTAX INTEGER {
	    unknown(0),
		num(1),
		string(2)
	}
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "Section trace format"
	::= { nnOCnEntry 2 }

expSTrc OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "Expected section trace"
	::= { nnOCnEntry 3 }

stfMode OBJECT-TYPE
	SYNTAX INTEGER {
        unknown(0),
		off(1),
		almonly(2)
	}
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "Section trace alarming mode"
	::= { nnOCnEntry 4 }

eBerTh OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Excessive Bit rate threshold"
	::= { nnOCnEntry 5 }

ocnPortMode OBJECT-TYPE
	SYNTAX INTEGER {
        unknown(0),
		sonet(1),
		sdh(2)
	}
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "Port mode can eithter be SONET or SDH"
	::= { nnOCnEntry 6 }

ocnLaserOffFarEndFail OBJECT-TYPE
    SYNTAX Status
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "It can either be Enabled or Disabled."
	::= { nnOCnEntry 7 }

oChTxActOcnPwr OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Actual Optical Channel transmit power. 
                 This variable is available upon GET-EXACT operations. No
                 value is returned with GET-NEXT."
	::= { nnOCnEntry 8 }

oChTxMinOcnPwr OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Minimum Optical Channel transmit power"
	::= { nnOCnEntry 9 }

oChTxMaxOcnPwr OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Maximum Optical Channel transmit power"
	::= { nnOCnEntry 10 }

oChRxActOcnPwr OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Actual Optical Channel receive power. 
                 This variable is available upon GET-EXACT operations. No
                 value is returned with GET-NEXT."
	::= { nnOCnEntry 11 }

oChRxMinOcnPwr OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Minimum Optical Channel receive power."
	::= { nnOCnEntry 12 }

oChRxMaxOcnPwr OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Maximum Optical Channel receive power."
	::= { nnOCnEntry 13 }


expSectionTraceMsg OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Expected section trace message. 
                 This variable contains data during GET
                 operations only. GET-NEXT returns No Assigned Value"
	::= { nnOCnEntry 14 }

incSectionTraceMsg OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Incoming section trace message
                 This variable contains data during GET
                 operations only. GET-NEXT returns No Assigned Value"
	::= { nnOCnEntry 15 }

ocnLoopbackType OBJECT-TYPE
	SYNTAX LoopbackType
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "Nothing is returned if Loopback is not active; 
	             otherwise the facility is returned."
	::= { nnOCnEntry 16 }

ocnPrimaryState OBJECT-TYPE
	SYNTAX PrimaryState
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Primary State of the faciltiy. Can only be modified
                 by changing the admin state."
	::= { nnOCnEntry 17 }

ocnSecondaryState OBJECT-TYPE
	SYNTAX DisplayString
    MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Secondary state for the facility. A facility can have
                 more than one secondary state as different combinations
                 of the individual secondary state. It is represented 
                 as a string to capture all the combinations. Those
                 combinations along with the Primary state are used 
                 to compute the admin state.  Can be any combination of 
                 flt, sgeo, lpbk, discd, ts, wrkrx, wrktx."
	::= { nnOCnEntry 18 }

ocnAdminState OBJECT-TYPE
	SYNTAX AdminState
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "This is a write-only variable. The user can restore
                 or remove facilities using this command. You restore
                 a facility by setting this variable to IS and remove
                 it by setting it to OOS. During Row-create, a user can 
                 use this variable to set the initial state of the facility.

                 Because this is a write-only variable, the user is expected
                 to read the Primary and Secondary state of the facility
                 to determine the state of the facility. "
	::= { nnOCnEntry 19 }

ocnAID OBJECT-TYPE
	SYNTAX  DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Facility AID as received from TL1. This should include
                 the FAC type, shelf id, slot, and port."
	::= { nnOCnEntry 20 }

nnOTMnTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF NnOTMnEntry
	MAX-ACCESS  not-accessible
	STATUS  current
	DESCRIPTION  "Contains entries for the OTM2/3 facilities"
	::= { nnOTMn 1 }

nnOTMnEntry OBJECT-TYPE
	SYNTAX NnOTMnEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION "An Entry for the OTM2/3 facilities"
	INDEX { ifIndex }
	::= { nnOTMnTable 1 }

NnOTMnEntry ::= 
	SEQUENCE {
		otmRowStatus
			RowStatus,
		osid
			DisplayString,
		otuTxFecFmt
			FecFormat,
		otuRxFecFmt
			FecFormat,
		oduTerm
			INTEGER,
		otuTxTTI
			DisplayString,
		oduTxTTI
			DisplayString,
		otuRxExpTTI
			DisplayString,
		oduRxExpTTI
			DisplayString,
		txPathId
			INTEGER,
		oChTxPwr
			DisplayString,
		oChTxActOtmPwr
			DisplayString,
		oChTxMinOtmPwr
			DisplayString,
		oChTxMaxOtmPwr
			DisplayString,
		oChRxActOtmPwr
			DisplayString,
		oChRxMinOtmPwr
			DisplayString,
		oChRxMaxOtmPwr
			DisplayString,
		oChTxWvlngthProv
			DisplayString,
		oChTxWvlngthMin
			DisplayString,
		oChTxWvlngthMax
			DisplayString,
		oChTxWvlngthSpacing
			DisplayString,
		oChRxActDisp
			DisplayString,
		oChRxActPmd
			DisplayString,
		oChRxPmdMax
			DisplayString,
		oChRxEchoTrace
			DisplayString,
		oChTxTrace
			DisplayString,
		oChTxTrace
			DisplayString,
		oChTxAssocFarEndRx
			DisplayString,
		otmPortMode
			INTEGER,
		tfMode
			INTEGER,
		oduTfMode
			INTEGER,
		otmLaserOffFarEndFail 
			Status,
		preFecSigFailThreshLevel
			DisplayString,
		otuSignalDegradeThreshLevel
			Integer32,
		oduMonitorEnabled
			INTEGER,
		lineRate
			INTEGER,
		otuExpTTI
			DisplayString,
		otuRxIncTTI
			DisplayString,
		oduRxIncTTI
			DisplayString,
		oduMonitorMsg
			DisplayString,
		otmLoopbackType
			LoopbackType,
		opu2reserved
			INTEGER,
		expectedPayloadType
			DisplayString,
		transmittedPayloadType
			DisplayString,
		receivedPayloadType
			DisplayString,
		otmPrimaryState
			PrimaryState,
		otmSecondaryState
			DisplayString,
		otmAdminState
			AdminState,
		otmAID
			DisplayString,
        otmGCC
            GccValues, 
        ospfCircuit
			DisplayString,
        oChDifferentialEncoding 
            INTEGER
	}

otmRowStatus OBJECT-TYPE
	SYNTAX RowStatus
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "Used to create/delete, put in service and out of
                     service, and edit."
	::= { nnOTMnEntry 1 }

osid OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "Optical Service ID"
	::= { nnOTMnEntry 2 }

otuTxFecFmt OBJECT-TYPE
	SYNTAX FecFormat
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "OTU transmit FEC format"
	::= { nnOTMnEntry 3 }

otuRxFecFmt OBJECT-TYPE
	SYNTAX FecFormat
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "OTU receive FEC format"
	::= { nnOTMnEntry 4 }

oduTerm OBJECT-TYPE
	SYNTAX INTEGER {
	    unknown(0),
		yes(1),
		no(2)
	}
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Indicates whether or not ODU TTI is terminated
                     on this OTMn facility. Possible values are
                     ODUTTITERM for OTM2 or ODUTERM for OTM3."
	::= { nnOTMnEntry 5 }

otuTxTTI OBJECT-TYPE
	SYNTAX DisplayString(SIZE(0..64))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "OTU transmit trail trace identifier."
	::= { nnOTMnEntry 6 }

oduTxTTI OBJECT-TYPE
	SYNTAX DisplayString(SIZE(0..64))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "ODU transmit trail trace identifier."
	::= { nnOTMnEntry 7 }

otuRxExpTTI OBJECT-TYPE
	SYNTAX DisplayString(SIZE(0..64))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "OTU receive trail trace identifier."
	::= { nnOTMnEntry 8 }

oduRxExpTTI OBJECT-TYPE
	SYNTAX DisplayString(SIZE(0..64))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "ODU receive trail trace identifer."
	::= { nnOTMnEntry 9 }

txPathId OBJECT-TYPE
	SYNTAX INTEGER(1..255)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "Transmit path identifier"
	::= { nnOTMnEntry 10 }

oChTxPwr OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "Provisioned output power"
	::= { nnOTMnEntry 11 }

oChTxActOtmPwr OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Actual optical channel transmit power. 
                 This variable is available upon GET-EXACT operations. No
                 value is returned with GET-NEXT."
	::= { nnOTMnEntry 12 }

oChTxMinOtmPwr OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Minimum transmit power."
	::= { nnOTMnEntry 13 }

oChTxMaxOtmPwr OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Maximum transmit power."
	::= { nnOTMnEntry 14 }

oChRxActOtmPwr OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Actual receive power 
                 This variable is available upon GET-EXACT operations. No
                 value is returned with GET-NEXT."
	::= { nnOTMnEntry 15 }

oChRxMinOtmPwr OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Minimum receive power"
	::= { nnOTMnEntry 16 }

oChRxMaxOtmPwr OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Maximum receive power"
	::= { nnOTMnEntry 17 }

oChTxWvlngthProv OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "Provisioned transmit wavelength"
	::= { nnOTMnEntry 18 }

oChTxWvlngthMin OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Minimum transmit wavelength"
	::= { nnOTMnEntry 19 }

oChTxWvlngthMax OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Maximum Transmit wavelength"
	::= { nnOTMnEntry 20 }

oChTxWvlngthSpacing OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Transmit wavelength spacing"
	::= { nnOTMnEntry 21 }

oChRxActDisp OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Actual receive dispersion. 
                 Data for this variable is only available from
                 the subtending card. This data is retrieved from
                 the SP with GET-NEXT. When there is no real-hardware
                 the GET request will get no data and GET-NEXT will
                 return SP data (most likely UNKNOWN). When there is
                 hardware, the GET-NEXT will still return SP data but
                 the GET will get the actual reading from the hardware.
                 This approach is necessary to make sure table views
                 and index discoveries are not stalled on queries to
                 the subtending cards."
	::= { nnOTMnEntry 22 }

oChRxActPmd OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Actual receive polarization mode dispersion (PMD) 
                 This variable is available upon GET-EXACT operations. No
                 value is returned with GET-NEXT."
	::= { nnOTMnEntry 23 }

oChRxPmdMax OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Maximum receive PMD"
	::= { nnOTMnEntry 24 }

oChRxEchoTrace OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Data for this variable is only available from
                 the subtending card. This data is retrieved from
                 the SP with GET-NEXT. When there is no real-hardware
                 the GET request will get no data and GET-NEXT will
                 return SP data (most likely UNKNOWN). When there is
                 hardware, the GET-NEXT will still return SP data but
                 the GET will get the actual reading from the hardware.
                 This approach is necessary to make sure table views
                 and index discoveries are not stalled on queries to
                 the subtending cards."
	::= { nnOTMnEntry 25 }

oChTxTrace OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Data for this variable is only available from
                 the subtending card. This data is retrieved from
                 the SP with GET-NEXT. When there is no real-hardware
                 the GET request will get no data and GET-NEXT will
                 return SP data (most likely UNKNOWN). When there is
                 hardware, the GET-NEXT will still return SP data but
                 the GET will get the actual reading from the hardware.
                 This approach is necessary to make sure table views
                 and index discoveries are not stalled on queries to
                 the subtending cards."
	::= { nnOTMnEntry 26 }

oChTxAssocFarEndRx OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Data for this variable is only available from
                 the subtending card. This data is retrieved from
                 the SP with GET-NEXT. When there is no real-hardware
                 the GET request will get no data and GET-NEXT will
                 return SP data (most likely UNKNOWN). When there is
                 hardware, the GET-NEXT will still return SP data but
                 the GET will get the actual reading from the hardware.
                 This approach is necessary to make sure table views
                 and index discoveries are not stalled on queries to
                 the subtending cards."
	::= { nnOTMnEntry 27 }


otmPortMode OBJECT-TYPE
	SYNTAX INTEGER {
	    unknown(0),
		sonet(1),
		sdh(2)
	}
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION ""
	::= { nnOTMnEntry 28 }

tfMode OBJECT-TYPE
	SYNTAX INTEGER {
	    unknown(0),
		off(1),
		almonly(2),
		linefail(3)
	}
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "Trace alarm mode"
	::= { nnOTMnEntry 29 }

oduTfMode OBJECT-TYPE
	SYNTAX INTEGER {
	    unknown(0),
		off(1),
		almonly(2)
	}
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "ODU trace alarm enable/disable"
	::= { nnOTMnEntry 30 }

otmLaserOffFarEndFail OBJECT-TYPE
    SYNTAX Status
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "Always enabled in Release 5.1"
	::= { nnOTMnEntry 31 }

preFecSigFailThreshLevel OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "Pre FEC Signal Fail Threshold Level"
	::= { nnOTMnEntry 32 }

otuSignalDegradeThreshLevel OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "OTU Signal Degrade Threshold Level"
	::= { nnOTMnEntry 33 }

oduMonitorEnabled OBJECT-TYPE
	SYNTAX INTEGER {
	    unknown(0),
		yes(1),
		no(2)
	}
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Beware of overloading ODUMONITOR in RTRV-TTI and
                     RTRV-OTM3"
	::= { nnOTMnEntry 34 }

lineRate OBJECT-TYPE
	SYNTAX INTEGER {
	    rate-uknown(0),
		rate-44G5(1),
		rate-9G95(2),
		rate-10G709(3),
		rate-11G05(4),
		rate-11G09(5)
	}
	MAX-ACCESS read-create
	STATUS current
	DESCRIPTION "Line Rate to be specified at create time only."
	::= { nnOTMnEntry 35 }

otuExpTTI OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Expected incoming OTU TTI message.
                 This variable is not available during table view,
                 walk, or any get-next operation. It only has data
                 on specific GET requsets to the facility."
	::= { nnOTMnEntry 36 }

otuRxIncTTI OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Receive OTU TTI message
                 This variable is not available during table view,
                 walk, or any get-next operation. It only has data
                 on specific GET requsets to the facility."
	::= { nnOTMnEntry 37 }

oduRxIncTTI OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Receive ODU TTI message
                 This variable is not available during table view,
                 walk, or any get-next operation. It only has data
                 on specific GET requsets to the facility."
	::= { nnOTMnEntry 38 }

oduMonitorMsg OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "ODU monitoring message
                 This variable is not available during table view,
                 walk, or any get-next operation. It only has data
                 on specific GET requsets to the facility."
	::= { nnOTMnEntry 39 }

otmLoopbackType OBJECT-TYPE
	SYNTAX LoopbackType
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "Facility if loopback is active; otherwise, nothing is
                     returned for this attribute"
	::= { nnOTMnEntry 40 }

opu2reserved OBJECT-TYPE
	SYNTAX INTEGER {
	    unknown(0),
		yes(1),
		no(2)
	}
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "YES/NO to using 7 overhead bytes for payload"
	::= { nnOTMnEntry 41 }

expectedPayloadType OBJECT-TYPE
	SYNTAX DisplayString(SIZE(1..2))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "This is received as a HEX value from TL1. The 
                 ranges are 0..FF. Since HEX can not be represented
                 in ASN.1, a string is used. For SET operations, the 
                 user can enter any valid HEX value from the range 0x0
                 to 0xFF. The values can be entered with or without a
                 preceding zero: i.e. 0 and 00 are equivalent. The agent
                 shall only verify the length of the input string 
                 is 1 or 2. Values like WX are valid strings but not valid
                 HEX and shall be rejected by the NE TL1 command not the
                 agent. 
                 This variable is available upon GET-EXACT operations. No
                 value is returned with GET-NEXT."
	::= { nnOTMnEntry 42 }

transmittedPayloadType OBJECT-TYPE
	SYNTAX DisplayString(SIZE(1..2))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "This is received as a HEX value from TL1. The 
                 ranges are 0..FF. Since HEX can not be represented
                 in ASN.1, a string is used. For SET operations, the 
                 user can enter any valid HEX value from the range 0x0
                 to 0xFF. The values can be entered with or without a
                 preceding zero: i.e. 0 and 00 are equivalent. The agent
                 shall only verify the length of the input string 
                 is 1 or 2. Values like WX are valid strings but not valid
                 HEX and shall be rejected by the NE TL1 command not the
                 agent. 
                 This variable is available upon GET-EXACT operations. No
                 value is returned with GET-NEXT."
	::= { nnOTMnEntry 43 }

receivedPayloadType  OBJECT-TYPE
	SYNTAX DisplayString(SIZE(1..2))
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "This is received as a HEX value from TL1. The 
                 ranges are 0..FF. Since HEX can not be represented
                 in ASN.1, a string is used. 
                 This variable is available upon GET-EXACT operations. No
                 value is returned with GET-NEXT."
	::= { nnOTMnEntry 44 }

otmPrimaryState OBJECT-TYPE
	SYNTAX PrimaryState
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Primary State of the faciltiy. Can only be modified
                 by changing the admin state."
	::= { nnOTMnEntry 45 }

otmSecondaryState OBJECT-TYPE
	SYNTAX DisplayString
    MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Secondary state for the facility. A facility can have
                 more than one secondary state as different combinations
                 of the individual secondary state. It is represented 
                 as a string to capture all the combinations. Those
                 combinations along with the Primary state are used 
                 to compute the admin state. Can be any combination of 
                 flt, sgeo, lpbk, discd, ts, wrkrx, wrktx."
	::= { nnOTMnEntry 46 }

otmAdminState OBJECT-TYPE
	SYNTAX AdminState
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "This is a write-only variable. The user can restore
                 or remove facilities using this command. You restore
                 a facility by setting this variable to IS and remove
                 it by setting it to OOS. During Row-create, a user can 
                 use this variable to set the initial state of the facility.

                 Because this is a write-only variable, the user is expected
                 to read the Primary and Secondary state of the facility
                 to determine the state of the facility. "
	::= { nnOTMnEntry 47 }

otmAID OBJECT-TYPE
	SYNTAX  DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Facility AID as received from TL1. This should include
                 the FAC type, shelf id, slot, and port."
	::= { nnOTMnEntry 48 }

otmGCC OBJECT-TYPE
    SYNTAX GccValues
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "A Get operation on this variable retrieves the 
                 LLSDCC Carrier GCC value. Setting this variable to NONE
                 removes OSPF circuit and LLSDCC carrier info. It is 
                 a NO-op if the GCC is initially NONE. Setting the 
                 variable to any other value would create LLSDCC COMMS 
                 with that GCC value.
                 unknonw is not a valid value for any set operation.
                 An unknown value for a get may indicate problems 
                 retrieving the GCC from the facility. Avoid issuing
                 set commands when an unknonw value is retrieved.
                 This variable is available upon GET-EXACT only. No
                 value is shown for GET-NEXT operations."
	::= { nnOTMnEntry 49 }

ospfCircuit OBJECT-TYPE
	SYNTAX DisplayString(SIZE(0..32))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "With GET operations, this variable shall return the
                 configured parameters of the OSPF circuit. In this
                 release only the NETAREA is supported. With SET 
                 operations, the NETAREA is to be supplied in the
                 format x.x.x.x. If no value is given, the default
                 (0.0.0.0) shall be used. All SET operations, whether
                 create or modify, will make sure that existing
                 OSPF circuits are deleted before creating or modifying
                 the new one with the new paramters (NETAREA). To delete
                 an OSPF circuit, set the GCC to none using the otmGCC
                 MIB variable.
                 This variable is available upon GET-EXACT only. No value
                 is shown for GET-NEXT operations."
	::= { nnOTMnEntry 50 }


oChDifferentialEncoding OBJECT-TYPE
	SYNTAX INTEGER {
	    unknown(0),
        none(1),
		hard(2),
		soft(3)
	}
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION ""
	::= { nnOTMnEntry 51 }

nnEthTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF NnEthEntry
	MAX-ACCESS  not-accessible
	STATUS  current
	DESCRIPTION  "Contains entries for ethernet 10G facilities"
	::= { nnEth 1 }

nnEthEntry OBJECT-TYPE
	SYNTAX NnEthEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION "This entry shall contain all the necessary attributes
                     for the ethernet 10G facilities in the 40G card"
	INDEX { ifIndex }
    ::= { nnEthTable 1 }

NnEthEntry ::= 
    SEQUENCE {
		ethRowStatus
			RowStatus,
		ethLaserOffFarEndFail
			Status,
		oChTxActEthPwr
			DisplayString,
		oChTxMinEthPwr
			DisplayString,
		oChTxMaxEthPwr
			DisplayString,
		oChRxActEthPwr
			DisplayString,
		oChRxMinEthPwr
			DisplayString,
		oChRxMaxEthPwr
			DisplayString,
		maxTransUnit
			INTEGER,
		flowControl
			INTEGER,
		equipment
			INTEGER,
		ethMapping
			INTEGER,
		ethLoopbackType
			LoopbackType,
		ethPrimaryState
			PrimaryState,
		ethSecondaryState
			DisplayString,
		ethAdminState
			AdminState,
		ethAID
			DisplayString
	}

ethRowStatus OBJECT-TYPE
	SYNTAX RowStatus
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "Create, delete, put in service, out of service, and edit"
	::= { nnEthEntry 1 }

ethLaserOffFarEndFail OBJECT-TYPE
    SYNTAX Status
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "To turn off Tx laser under certain failure scenarios"
	::= { nnEthEntry 2 }

oChTxActEthPwr OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "The target will be of the format xx.x and dBm will be 
                     assumed for powers within design/accuracy range.
                     Powers outside the accuracy/design range will be clamped
                     at: OOR-HI or OOR-LO (out of range high and low 
                     respectively) 
                 This variable is available upon GET-EXACT operations. No
                 value is returned with GET-NEXT."
	::= { nnEthEntry 3 }

oChTxMinEthPwr OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "The target will be of the format xx.x and dBm will 
                     be assumed"
	::= { nnEthEntry 4 }

oChTxMaxEthPwr OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "The target will be of the format xx.x and dBm will 
	             be assumed"
	::= { nnEthEntry 5 }

oChRxActEthPwr OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "The target will be of the format xx.x and dBm will be 
                     assumed for powers within design/accuracy range.
                     Powers outside the accuracy/design range will be clamped
                     at: OOR-HI or OOR-LO (out of range high and low 
                     respectively) 
                 This variable is available upon GET-EXACT operations. No
                 value is returned with GET-NEXT."
	::= { nnEthEntry 6 }

oChRxMinEthPwr OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "The target will be of the format xx.x and dBm will 
                     be assumed"
	::= { nnEthEntry 7 }

oChRxMaxEthPwr OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "The target will be of the format xx.x and dBm will 
                     be assumed"
	::= { nnEthEntry 8 }

maxTransUnit OBJECT-TYPE
	SYNTAX INTEGER {
	    mtu-unknown(0), 
		mtu-1600(1),
		mtu-9600(2)
	}
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "Maximum transmission unit"
	::= { nnEthEntry 9 }

flowControl OBJECT-TYPE
	SYNTAX INTEGER {
	    unknown(0),
		none(1),
		asymmetric(2),
		symmetric(3),
		preeemptive(4)
	}
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION ""
	::= { nnEthEntry 10 }

equipment OBJECT-TYPE
	SYNTAX INTEGER {
	    xge-unknown(0),
		xge-lan(1),
		xge-wan(2)
	}
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION ""
	::= { nnEthEntry 11 }

ethMapping OBJECT-TYPE
	SYNTAX INTEGER {
	    unknown(0),
		prop237(1),
		prop238(2),
		gfp-mactr(3),
		gfp-std(4),
                gfp-mactr192(5),
                gfp-std192(6),
                gfp-mactr64(7),
                gfp-std64(8),
                gfp-macostr(9),
                gfp-macostr192(10),
                gfp-macostr64(11),
                ull(12)
	}
	MAX-ACCESS read-create
	STATUS current
	DESCRIPTION "Sets the non-client OTM2 OTU rate and client mapping"
	::= { nnEthEntry 12 }

ethLoopbackType OBJECT-TYPE
	SYNTAX LoopbackType
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "Facility if loopback is active; otherwise nothing is
                     returned for this attribute."
	::= { nnEthEntry 13 }

ethPrimaryState OBJECT-TYPE
	SYNTAX PrimaryState
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Primary State of the faciltiy. Can only be modified
                 by changing the admin state."
	::= { nnEthEntry 14 }

ethSecondaryState OBJECT-TYPE
	SYNTAX DisplayString 	
    MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Secondary state for the facility. A facility can have
                 more than one secondary state as different combinations
                 of the individual secondary state. It is represented 
                 as a string to capture all the combinations. Those
                 combinations along with the Primary state are used 
                 to compute the admin state.Can be any combination of 
                 flt, sgeo, lpbk, discd, ts, wrkrx, wrktx."
	::= { nnEthEntry 15 }

ethAdminState OBJECT-TYPE
	SYNTAX AdminState
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "This is a write-only variable. The user can restore
                 or remove facilities using this command. You restore
                 a facility by setting this variable to IS and remove
                 it by setting it to OOS. During Row-create, a user can 
                 use this variable to set the initial state of the facility.

                 Because this is a write-only variable, the user is expected
                 to read the Primary and Secondary state of the facility
                 to determine the state of the facility. "
		::= { nnEthEntry 16 }

ethAID OBJECT-TYPE
	SYNTAX  DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Facility AID as received from TL1. This should include
                 the FAC type, shelf id, slot, and port."
	::= { nnEthEntry 17 }

nnWanTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF NnWanEntry
	MAX-ACCESS  not-accessible
	STATUS  current
	DESCRIPTION  "Contains entries for ethernet 10G facilities"
	::= { nnWAN 1 }

nnWanEntry OBJECT-TYPE
	SYNTAX NnWanEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION "This entry shall contain all the necessary attributes
                     for the ethernet 10G facilities in the 40G card"
	INDEX { ifIndex }
    ::= { nnWanTable 1 }

NnWanEntry ::= 
    SEQUENCE {
		frameChecksum
			INTEGER,
		wanMapping
			INTEGER,
		gfpRfi
			INTEGER,
		gfpRtDelay
			INTEGER,
		condType
			INTEGER,
		preamble
			INTEGER,
		fcsErrFrames
			INTEGER,
		transmittedUPI
			DisplayString,
		wanPrimaryState
			PrimaryState,
		wanSecondaryState
			DisplayString,
		wanAdminState
			AdminState,
		wanAID
			DisplayString
	}

frameChecksum OBJECT-TYPE
	SYNTAX INTEGER(0|16|32)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "For mapping=GFP-F, value can be 0 or 32"
	::= { nnWanEntry 1 }

wanMapping OBJECT-TYPE
	SYNTAX INTEGER {
	    unknown(0),
		gfp-f(1),
		gfp-t(2)
	}
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "GFP-F is only supported value"
	::= { nnWanEntry 2 }

gfpRfi OBJECT-TYPE
	SYNTAX INTEGER {
        unknown(0),
		enable(1),
		disable(2)
	}
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "Enable/Disable"
	::= { nnWanEntry 3 }

gfpRtDelay OBJECT-TYPE
	SYNTAX INTEGER {
        unknown(0),
		enable(1),
        disable(2)
    }
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "Enable/Disable"
	::= { nnWanEntry 4 }

condType OBJECT-TYPE
	SYNTAX INTEGER {
	    unknown(0),
		gfpcmf(1)
	}
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "GFP CMF is the only supported value."
	::= { nnWanEntry 5 }

preamble OBJECT-TYPE
	SYNTAX INTEGER {
        unknown(0),
		keep(1),
		discard(2)
	}
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "KEEP/DISCARD ethernet preamble"
	::= { nnWanEntry 6 }

fcsErrFrames OBJECT-TYPE
	SYNTAX INTEGER {
        unknown(0),
		keep(1),
		discard(2)
	}
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "KEEP/DISCARD FCS-errored frames end-to-end."
	::= { nnWanEntry 7 }

transmittedUPI OBJECT-TYPE
	SYNTAX DisplayString(SIZE(1..2))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "This is received as a HEX value from TL1. The 
                 ranges are 0..FF. Since HEX can not be represented
                 in ASN.1, a string is used. For SET operations, the 
                 user can enter any valid HEX value from the range 0x0
                 to 0xFF. The values can be entered with or without a
                 preceding zero: i.e. 0 and 00 are equivalent. The agent
                 shall only verify the length of the input string 
                 is 1 or 2. Values like WX are valid strings but not valid
                 HEX and shall be rejected by the NE TL1 command not the
                 agent. 
                 
                 Editable when the mapped non-client OTM2 attribute
                 opu2resvd=YES."
	::= { nnWanEntry 8 }

wanPrimaryState OBJECT-TYPE
	SYNTAX PrimaryState
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Primary State of the faciltiy. Can only be modified
                 by changing the admin state."
	::= { nnWanEntry 9 }

wanSecondaryState OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Secondary state for the facility. A facility can have
                 more than one secondary state as different combinations
                 of the individual secondary state. It is represented 
                 as a string to capture all the combinations. Those
                 combinations along with the Primary state are used 
                 to compute the admin state.Can be any combination of 
                 flt, sgeo, lpbk, discd, ts, wrkrx, wrktx."
	::= { nnWanEntry 10 }

wanAdminState OBJECT-TYPE
	SYNTAX AdminState
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION "This is a write-only variable. The user can restore
                 or remove facilities using this command. You restore
                 a facility by setting this variable to IS and remove
                 it by setting it to OOS. During Row-create, a user can 
                 use this variable to set the initial state of the facility.

                 Because this is a write-only variable, the user is expected
                 to read the Primary and Secondary state of the facility
                 to determine the state of the facility. "
	::= { nnWanEntry 11 }

wanAID OBJECT-TYPE
	SYNTAX  DisplayString
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION "Facility AID as received from TL1. This should include
                 the FAC type, shelf id, slot, and port."
	::= { nnWanEntry 12 }

END