BUNDLE-MIB DEFINITIONS ::= BEGIN

IMPORTS
        MODULE-IDENTITY,OBJECT-TYPE,OBJECT-IDENTITY,NOTIFICATION-TYPE, 
	  mib-2,IpAddress,Integer32,TimeTicks,Counter32    
            	FROM SNMPv2-SMI
        TruthValue,RowStatus,DisplayString
               	FROM SNMPv2-TC
        NOTIFICATION-GROUP
                  FROM SNMPv2-CONF
        ntEnterpriseDataTasmanMgmt 	
	            FROM NT-ENTERPRISE-DATA-MIB;

nnbundleMib MODULE-IDENTITY
        LAST-UPDATED	"9907010000Z" 
        ORGANIZATION	"Nortel Networks"
	  CONTACT-INFO
        	" Nortel Networks
        	8200 Dixie Road
        	Brampton, Ontario L6T 5P6
        	Canada        
        	1-800-4Nortel 
        	www.nortelnetworks.com "        
        DESCRIPTION
        	"Bundle MIB for defining bundle parameters"
        REVISION	"9904230000Z"        
	  DESCRIPTION
        	"Initial version of this MIB module."
        ::= { ntEnterpriseDataTasmanMgmt 13 } 

-- bundleTable definition
-- The following bundle table lists all parameters associated with a 
-- bundle.  Items such as encapsulation, IP address, and subnet mask
-- need to have proper values for the bundle to function properly.
-- Default values may not work.

nnbundleTable         OBJECT-TYPE
        SYNTAX          SEQUENCE OF NnBundleTableEntry
        MAX-ACCESS      not-accessible
        STATUS          current
        DESCRIPTION 
                        "Bundle management related 
                        parameters are defined in this table."
        ::= {nnbundleMib 1}

nnbundleTableEntry    OBJECT-TYPE
        SYNTAX          	NnBundleTableEntry
        MAX-ACCESS      not-accessible
        STATUS          current
        DESCRIPTION     "Bundle parameter entries are listed in this 
                        table."
        INDEX           { nnbundleId }
        ::= {nnbundleTable 1}

NnBundleTableEntry ::= SEQUENCE {
		nnbundleId                         	Integer32,
		nnbundleName                       	DisplayString,
		nnbundleContact                    	DisplayString,
		nnbundleDescr                     	DisplayString,
		nnbundleEncapsulation             INTEGER,
		nnbundleDropEs                     	Integer32,
		nnbundleDropSes                    	Integer32,
		nnbundleDropUas                    	Integer32,
		nnbundleDropEev                    	Integer32,
		nnbundleDropBes                    	Integer32,
		nnbundleDropBbe                    	Integer32,
		nnbundleDropLofc                   	Integer32,
		nnbundleDropBpv                    	Integer32,
		nnbundleDropCss                    	Integer32,
		nnbundleDropOof                    	Integer32,
		nnbundleDropCrc                    	Integer32,
		nnbundleIpAddr                     	IpAddress,
		nnbundleSubnetMask              	IpAddress,
		nnbundleSrcForwardingAddrPrimary   	IpAddress,
		nnbundleSrcForwardingAddrSecondary 	IpAddress,
		nnbundleRestoreMethod          	INTEGER,
		nnbundleLinkRestoralTime      	Integer32,
		nnbundleStatus                        INTEGER,
		nnbundleLinkRestore              	OCTET STRING (SIZE (4)),
		nnbundleNoOfLinks                  	Integer32,
		nnbundleTotalBw                    	Integer32,
		nnbundleRowStatus                 	RowStatus,
		nnbundleIpUnnumbered         	DisplayString,
		nnbundleIpMulticast                	INTEGER,
		nnbundleDirectedBcast            	INTEGER,
		nnbundleIcmpUnreachable       	INTEGER,
		nnbundleIcmpRedirect             	INTEGER,
		nnbundleClearCounters           	Integer32,
		nnbundleTrackHoldDownTimer  INTEGER,
		nnbundleDropPackets           Counter32
        }

nnbundleId            OBJECT-TYPE
        SYNTAX          Integer32 
        MAX-ACCESS      not-accessible  
        STATUS          current
        DESCRIPTION     "bundleId is the identifier of a bundle. To 
                        configure a bundle, this parameter must be 
                        used as the index. This is assigned internally 
                        by the system. Whenever a row creation 
                        needs to occur in the bundleTable, the 
                        bundleId is entered as 65535."
        ::= { nnbundleTableEntry 1}

nnbundleName          OBJECT-TYPE
        SYNTAX          DisplayString (SIZE (1..8))
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "Name of the bundle. To configure a bundle, 
                        this parameter must be set. That is, a 
                        descriptive name should be given to a bundle. 
                        The maximum length of a bundle name is 8 
                        characters. This parameter is set once during 
                        the creation of a bundle. A bundle can not be 
                        renamed." 
        ::= { nnbundleTableEntry 2}

nnbundleContact       OBJECT-TYPE
        SYNTAX          DisplayString (SIZE (1..15))
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "Name of the person who can be contacted 
                        for information about the bundle. The maximum 
                        length for this parameter is 15 characters. 
                        This parameter can be set after the bundle 
                        is named and before the links are assigned."
        DEFVAL          { "" }
        ::= { nnbundleTableEntry 3}

nnbundleDescr         OBJECT-TYPE
        SYNTAX          DisplayString (SIZE (1..76))
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "Brief description of the bundle. The maximum 
                        length of this parameter is 25 characters. 
                        This parameter can be set after the bundle
                        is named and before the links are assigned."
        DEFVAL          { "" }
        ::= { nnbundleTableEntry 4 }

nnbundleEncapsulation OBJECT-TYPE
        SYNTAX      INTEGER {
                        noEncap(1),
                        ppp(2),
                        hdlc(3),
                        frameRelay(4)
                    }
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "Specifies the type of protocol encapsulation 
                        for the bundle. To configure protocol-specific 
                        parameters for a bundle, the bundle must first 
                        be encapsulated with that protocol. To 
                        unconfigure the encapsulation type, this 
                        variable should be set to noEncap."
        DEFVAL          { noEncap }
        ::= { nnbundleTableEntry 5 }

nnbundleDropEs        OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "seconds"
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "The length of time in seconds that the error 
                        condition Errored Seconds exists before a link is 
                        dropped. This parameter can be configured only 
                        for multilink bundles and after the 
                        bundle is encapsulated." 
        DEFVAL          { 0 } 
        ::= { nnbundleTableEntry 6}

nnbundleDropSes       OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "seconds"
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "The length of time in seconds that the error
                        condition Severely Errored Seconds exists 
                        before a link is dropped. This parameter can 
                        be configured only for multilink bundles and 
                        after the bundle is encapsulated."
        DEFVAL          { 0 } 
    ::= { nnbundleTableEntry 7}

nnbundleDropUas       OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "seconds"

        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "The length of time in seconds that the error
                        condition Unavailable Seconds exists before a 
                        link is dropped. This parameter can be 
                        configured only for multilink bundles and 
                        after the bundle is encapsulated."
        DEFVAL          { 0 } 
        ::= { nnbundleTableEntry 8}

nnbundleDropEev       OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "seconds"
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "The length of time in seconds that the error
                        condition ESF Error Events exists before a 
                        link is dropped. This parameter can be 
                        configured only for multilink bundles and 
                        after the bundle is encapsulated."
        DEFVAL          { 0 } 
        ::= { nnbundleTableEntry 9}

nnbundleDropBes       OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "seconds"
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "The length of time in seconds that the error
                        condition Bursty Errored Seconds 
			(Applicable only for T1 links) exists before a 
                        link is dropped. This parameter can be 
                        configured only for multilink bundles and 
                        after the bundle is encapsulated."
        DEFVAL          { 0 } 
        ::= { nnbundleTableEntry 10}

nnbundleDropBbe       OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "seconds"
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "The length of time in seconds that the error
                        condition Threshold for Background Blocked Errors 
			(Applicable only for E1 links) exists before a 
                        link is dropped. This parameter can be 
                        configured only for multilink bundles and 
                        after the bundle is encapsulated."
        DEFVAL          { 0 } 
        ::= { nnbundleTableEntry 11}

nnbundleDropLofc       OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "seconds"
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "The length of time in seconds that the error
                        condition Loss Of Frame Count exists before a 
                        link is dropped. This parameter can be 
                        configured only for multilink bundles and 
                        after the bundle is encapsulated."
        DEFVAL          { 0 } 
        ::= { nnbundleTableEntry 12}

nnbundleDropBpv       OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "seconds"
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "The length of time in seconds that the error
                        condition BiPolar Violation exists before a 
                        link is dropped. This parameter can be 
                        configured only for multilink bundles and 
                        after the bundle is encapsulated."
        DEFVAL          { 0 } 
        ::= { nnbundleTableEntry 13}

nnbundleDropCss       OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "seconds"
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "The length of time in seconds that the error
                        condition Controlled Slip Second exists before a 
                        link is dropped. This parameter can be 
                        configured only for multilink bundles and 
                        after the bundle is encapsulated."
        DEFVAL          { 0 } 
        ::= { nnbundleTableEntry 14}

nnbundleDropOof       OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "seconds"
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "The length of time in seconds that the error
                        condition  Out Of Frame exists before a 
                        link is dropped. This parameter can be 
                        configured only for multilink bundles and 
                        after the bundle is encapsulated."
        DEFVAL          { 0 } 
        ::= { nnbundleTableEntry 15}

nnbundleDropCrc       OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "seconds"
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "The length of time in seconds that the error
                        condition Cyclic Redundancy Check exists before a 
                        link is dropped. This parameter can be 
                        configured only for multilink bundles and 
                        after the bundle is encapsulated."
        DEFVAL          { 0 } 
        ::= { nnbundleTableEntry 16}

nnbundleIpAddr        OBJECT-TYPE
        SYNTAX          IpAddress
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "The bundle's source IP address. This is one 
                        of the parameters required to set up IP 
                        multiplexing for a bundle. This parameter 
                        can be configured only when the bundle is 
                        encapsulated. Also the parameters bundleIpAddr 
                        and bundleSubnetMask have to be set together 
                        during the same request. To unconfigure the IP 
                        address, a set operation is performed with 
                        the value 0.0.0.0" 
        DEFVAL          { 0 }  
        ::= { nnbundleTableEntry 17}

nnbundleSubnetMask    OBJECT-TYPE
        SYNTAX          IpAddress
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "This parameter represents the source subnet 
                        mask address. This is one of the parameters 
                        required to set up IP multiplexing for a 
                        bundle. This parameter is set along with the 
                        bundleIpAddr parameter during the same 
                        request." 
        DEFVAL          { 0 }  
        ::= { nnbundleTableEntry 18}

nnbundleSrcForwardingAddrPrimary  OBJECT-TYPE
        SYNTAX          IpAddress
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "The bundle's destination IP address. This is 
                        one of the parameters required to set up IP 
                        multiplexing for a bundle. This parameter can 
                        be configured when the bundle has been 
                        configured for IP multiplexing. To unconfigure 
                        the source forwarding address, a set operation 
                        is performed with the value 0.0.0.0. This is
                        the primary source forwarding address" 
        DEFVAL          { 0 }  
        ::= { nnbundleTableEntry 19}

nnbundleSrcForwardingAddrSecondary OBJECT-TYPE
        SYNTAX          IpAddress
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "The bundle's secondary or backup destination 
                        address. This address will be used only if  
                        the primary address uses an ethernet interface
                        and failover is enabled on that interface and
                        the interface goes down. The secondary source
                        forwarding address is an optional parameter, 
                        it should be a gateway on the alternate
                        ethernet This parameter is set along with the
                        primary source forwarding address parameter. 
                        To unconfigure this parameter a set operation 
                        is performed with the value 0.0.0.0 for the
                        primary address, or a primary address is set
                        with no secondary, or both primary and 
                        secondary are set to 0.0.0.0"
        DEFVAL          { 0 }  
        ::= { nnbundleTableEntry 20}

nnbundleRestoreMethod OBJECT-TYPE
        SYNTAX      INTEGER {
                        manual(1),
                        automatic(2)}
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION     "bundleRestoreMethod defines how a dropped 
                        link of a multilink bundle will be restored. 
                        It can be done either manually or 
                        automatically. If the restore mode is 
                        automatic, the parameter bundleLinkRestoralTime 
                        should be set (in seconds) during the same 
                        request." 
        DEFVAL          { automatic }
        ::= { nnbundleTableEntry 21}

nnbundleLinkRestoralTime  OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "seconds"
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "Error-free time interval (in seconds) that 
                        must pass before a link is automatically 
                        restored. This parameter can be set when the 
                        bundleRestoreMethod is automatic." 
        DEFVAL          { 120 }
        ::= { nnbundleTableEntry 22 }

nnbundleStatus        OBJECT-TYPE
        SYNTAX      INTEGER {
                        enable(1),
                        disable(2)
                    }
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION     "bundleStatus shutdowns the bundle. Although 
                        the default is 'enable,' the bundle remains 
                        disabled until all necessary parameters are 
                        present" 
        DEFVAL          { enable }
        ::= { nnbundleTableEntry 23 }

nnbundleLinkRestore   OBJECT-TYPE
        SYNTAX          OCTET STRING (SIZE (4)) 
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION     "bundleLinkRestore specifies the links to be 
                        restored manually. This parameter is configured 
                        when the value of bundleRestoreMethod is manual. 
                        The user needs to specify the link/s to be 
                        restored. LSB in the OCTET STRING represents 
                        T1 Number 1. For example, to restore links 1-4 
                        the value should be set to 000F"
        ::= { nnbundleTableEntry 24 }

nnbundleNoOfLinks     OBJECT-TYPE
        SYNTAX          Integer32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Indicates the number of links configured in 
                        the bundle." 
        ::= { nnbundleTableEntry 25 }

nnbundleTotalBw       OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "kbps"
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "Indicates the total bandwidth for this bundle.
                        The bundle bandwidth is the aggregated band-
                        widths of all the links assigned to a 
                        particular bundle." 
    ::= { nnbundleTableEntry 26 }

nnbundleRowStatus OBJECT-TYPE
        SYNTAX          RowStatus
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "bundleRowStatus is used to add/delete a row 
                        in the table. Adding or deleting a row 
                        corresponds to creating a bundle or deleting
                        a bundle.  In order to add a row to the bundle 
                        table, a set on this parameter should be done 
                        with the value 4 (createAndGo) and 
                        bundleId parameter set with the value of 65535. 
                        A request to create a row can be 
                        completed successfully only if a set on the 
                        bundleRowStatus and a set on the bundleName 
                        come in the same request. To delete a row 
                        this parameter has to be set with the value 6
                        (destroy)." 
        ::= { nnbundleTableEntry 27}

nnbundleIpUnnumbered      OBJECT-TYPE
        SYNTAX          DisplayString (SIZE (1..8))
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "Name of the bundle. To configure unnumbered,
                        this parameter must be set. 
                        The maximum length of a bundle name is 8 
                        characters. "
        ::= { nnbundleTableEntry 28}

nnbundleIpMulticast OBJECT-TYPE
        SYNTAX      INTEGER {
                        noMcast(0),
                        pass(1),
                        block(2),
                        ospfrip2(3)
                    }
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "Specifies the Ip multicast operation."
        DEFVAL          { noMcast }
        ::= { nnbundleTableEntry 29 }

nnbundleDirectedBcast   OBJECT-TYPE
        SYNTAX      INTEGER {
                        disable(0),
                        enable(1)
                    }
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "Enable/disable forwarding of directed broadcasts
			 on this interface."
        DEFVAL          { enable }
        ::= { nnbundleTableEntry 30 }

nnbundleIcmpUnreachable   OBJECT-TYPE
        SYNTAX      INTEGER {
                        disable(0),
                        enable(1)
                    }
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "Enable/disable ICMP destination unreachable messages
                         on this interface"
        DEFVAL          { enable }
        ::= { nnbundleTableEntry 31 }

nnbundleIcmpRedirect   OBJECT-TYPE
        SYNTAX      INTEGER {
                        disable(0),
                        enable(1)
                    }
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "Enable/disable ICMP redirect messages on this
                         on this interface"
        DEFVAL          { enable }
        ::= { nnbundleTableEntry 32 }

nnbundleClearCounters 	OBJECT-TYPE
	SYNTAX  	Integer32
	MAX-ACCESS  	read-create
	STATUS  	current
	DESCRIPTION	"Perform a clearing of the counters operation"
	::= { nnbundleTableEntry 33 }

nnbundleTrackHoldDownTimer OBJECT-TYPE
        SYNTAX          INTEGER (1..100)
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "Indicates the tracking hold down timer."
        DEFVAL          { 5 }
    ::= { nnbundleTableEntry 34 }

nnbundleDropPackets  OBJECT-TYPE
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION     "The number of packets dropped by a WAN interface 
        when the agent encounters packet drops due to lack of buffer availability for transmission etc. Also, packets may be          dropped for various reasons like Buffer over flow, packet too long, CRC errors, invalid packet length, system 
        errors etc. This list is only a subset of  the numerous reasons for the packets that can be dropped by the agent per         interface"
    ::= { nnbundleTableEntry 35 }
    
-- bundleLinkTable definition
nnbundleLinkTable     OBJECT-TYPE
        SYNTAX          SEQUENCE OF NnBundleLinkEntry
        MAX-ACCESS      not-accessible
        STATUS          current
        DESCRIPTION     "All the parameters related to the assigned 
                        links of a bundle are defined in 
                        bundleLinkTable. A row in this table can be 
                        created when a bundle with the corresponding 
                        bundleId already exists in the bundleTable."
        ::= { nnbundleMib 2 }

nnbundleLinkEntry     OBJECT-TYPE
        SYNTAX          NnBundleLinkEntry
        MAX-ACCESS      not-accessible
        STATUS          current
        DESCRIPTION     "Link parameters that relate to a 
                        given bundle are specified in this table."
        INDEX           { nnbundleId , nnbundleLinkT1Num }
        ::= { nnbundleLinkTable 1 }

NnBundleLinkEntry ::= SEQUENCE {
        nnbundleLinkT1Num         Integer32,  
        nnbundleLinkTimeSlots     OCTET STRING (SIZE (4)),
        nnbundleLinkType          INTEGER,
        nnbundleLinkSpeed         INTEGER,
        nnbundleLinkInvertedData  TruthValue,
        nnbundleLinkPhysIfNum    Integer32,
        nnbundleLinkDiffDelay     Integer32,
        nnbundleLinkBw            Integer32,
        nnbundleLinkStatus        INTEGER,
        nnbundleLinkRowStatus     RowStatus
        }

nnbundleLinkT1Num     OBJECT-TYPE
        SYNTAX          Integer32 
        MAX-ACCESS      not-accessible
        STATUS          current
        DESCRIPTION     "bundleLinkT1Num is the number of the T1 link 
                        being added to a specific bundle. For example, 
                        to assign link number 4, the value of this 
                        parameter should be set to 4. However, the 
                        design of SNMP's link creation is different 
                        from that of the system CLI. In SNMP, only 
                        one link can be created at a time whereas in 
                        the system CLI, multiple links can be 
                        configured in a single request. This parameter 
                        is mandatory for row creation in the interfaces 
                        with CT3 and T1 link types ."      
       ::= { nnbundleLinkEntry 1 }

nnbundleLinkTimeSlots OBJECT-TYPE
        SYNTAX          OCTET STRING (SIZE (4)) 
        MAX-ACCESS      read-create 
        STATUS          current
        DESCRIPTION     "bundleLinkTimeSlots indicates the DS0 channels 
                        in a fractional T1 link. The LSB in the OCTET 
                        STRING represents DS0 channel number 1. For 
                        example, to assign DS0 channels 1-4, the value 
                        of this parameter should be set to 000F"
        DEFVAL          { "00ffffff" }
        ::= { nnbundleLinkEntry 2 }


nnbundleLinkType      OBJECT-TYPE
        SYNTAX          INTEGER {
                            ct3(1),
                            t1(2),
                            e1(3),
                            hssi(4),
                            t3(5),
                            v35(6),
				    ft1(7),
				    fe1(8),
				    x21(9),
				    s530(10),
				    s530A(11),
				    s449(12),
				    s232(13)
                        }
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "bundleLinkType specifies the interface type 
                        (i.e.,CT3,T1,T3,HSSI,V35,X21,S530,S530A,S449,S232 etc.,) 
                        of the link being assigned to the bundle. This is a 
                        mandatory parameter for Row creation in the 
                        bundleLinkTable." 
        ::= { nnbundleLinkEntry 3 }


nnbundleLinkSpeed     OBJECT-TYPE
        SYNTAX          INTEGER {
                            kbps56(1),
                            kbps64(2),
				    notApplicable(3)
                        }
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "The bundleLinkSpeed specifies the transmission 
                        speed of all DS0 channels in a bundle." 
        DEFVAL          { 2 }
        ::= { nnbundleLinkEntry 4 }

nnbundleLinkInvertedData  OBJECT-TYPE
        SYNTAX          TruthValue
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "Setting bundleLinkInvertedData parameter to 
                        true will have the system invert data on all 
                        DS0 channels before transmission. Data 
                        inversion is used only for HDLC-encapsulated 
                        bundles." 
        DEFVAL          { false }
        ::= { nnbundleLinkEntry 5 }

nnbundleLinkPhysIfNum OBJECT-TYPE
        SYNTAX          Integer32
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "bundleLinkPhysIfNum specifies the interface
                        number of the interface type such as CT3, 
                        HSSI, T3 on which this link is being created. 
                        This variable holds significance only for 
                        link types CT3, HSSI and T3. It is a 
                        mandatory variable for row creation for link 
                        types CT3, HSSI, and T3."
        DEFVAL          { 0 }
        ::= { nnbundleLinkEntry 6 }
    
nnbundleLinkDiffDelay OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "milli-seconds"
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "bundleLinkDiffDelay specifies the maximum 
                        differential delay allowed on the links in a 
                        multilink bundle.  If the packet delay on any 
                        link exceeds the differential delay set for a 
                        bundle, that link is dropped from the bundle." 
        ::= { nnbundleLinkEntry 7}

nnbundleLinkBw        OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "kbps"
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "bundleLinkBw indicates the bandwidth of the 
                        link.  The bandwidth of an individual link 
                        depends upon its configuration.  For example, 
                        in a link of type T1, its bandwidth will 
                        depend upon whether the link is a full T1 or 
                        a fractional T1 consisting of 24 DS0 timeslots."
        ::= { nnbundleLinkEntry 8}

nnbundleLinkStatus    OBJECT-TYPE
        SYNTAX          INTEGER {
                            up(1),
                            down(2)
                        }   
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "bundleLinkStatus indicates whether a 
                        particular link in a bundle is up or down.  
                        The link can go down due to various reasons 
                        such as differential delay, a broken link, 
                        or negotiation problems at the far end."
        ::= { nnbundleLinkEntry 9}

nnbundleLinkRowStatus OBJECT-TYPE
        SYNTAX          RowStatus
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "bundleLinkRowStatus is used to add or delete 
                        a row in the table. To create a row, this 
                        parameter is set to value 4(createAndGo). To 
                        delete a row, this parameter is set to a value 
                        6(destroy)." 
        ::= { nnbundleLinkEntry 10}

-- bundleTrackTable definition
nnbundleTrackTable        OBJECT-TYPE
        SYNTAX          SEQUENCE OF NnBundleTrackEntry
        MAX-ACCESS      not-accessible
        STATUS          current
        DESCRIPTION     "All the parameters related to bundle
                        tracking are includede in BundleTrackTable."
        ::= { nnbundleMib 3 }

nnbundleTrackEntry     OBJECT-TYPE
        SYNTAX          NnBundleTrackEntry
        MAX-ACCESS      not-accessible
        STATUS          current
        DESCRIPTION     "Bundle Track parameters that relate to a 
                        given bundle are specified in this table."
        INDEX           { nnbundleId , nntrackIntfId }
        ::= { nnbundleTrackTable 1 }

NnBundleTrackEntry ::= SEQUENCE {
        nntrackIntfId             Integer32,
        nntrackIntfName           DisplayString,
        nntrackIntfStatus         INTEGER,
        nntrackIntfRowStatus      RowStatus
        }

nntrackIntfId            OBJECT-TYPE
        SYNTAX          Integer32 
        MAX-ACCESS      not-accessible  
        STATUS          current
        DESCRIPTION     "trackIntfId is the identifier of the
                         bundle being tracked."
        ::= { nnbundleTrackEntry 1 } 
        
nntrackIntfName          OBJECT-TYPE
        SYNTAX          DisplayString (SIZE (1..8))
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "Name of the bundle being tracked."
        ::= { nnbundleTrackEntry 2 }


nntrackIntfStatus        OBJECT-TYPE
        SYNTAX      INTEGER {
                        up(1),
                        down(2)
                    }
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "bundleStatus displays the status of the
                         bundle being tracked."
        ::= { nnbundleTrackEntry 3 }

nntrackIntfRowStatus      OBJECT-TYPE
        SYNTAX          RowStatus
        MAX-ACCESS      read-create   
        STATUS          current
        DESCRIPTION   
            "Used to configure or delete a tracking interface. To configure
            a interface, set the value of this object to createAndGo. To delete
            a interface, set the value of this object to destroy."
        ::= { nnbundleTrackEntry 4 }
    
-- Loopback Interface Table

nnloopbackIfTable	OBJECT-TYPE
        SYNTAX		SEQUENCE OF NnLoopbackIfTableEntry
        MAX-ACCESS	not-accessible
        STATUS		current
        DESCRIPTION	"A list of Loopback Interface table entries 
			for this entity. "
	::= { nnbundleMib 4 }

nnloopbackIfTableEntry    OBJECT-TYPE
        SYNTAX          NnLoopbackIfTableEntry
        MAX-ACCESS      not-accessible
        STATUS          current
        DESCRIPTION     "Loopback Interface parameter entries are 
			listed in this table."
        INDEX           { nnloopbackIfId }
        ::= {nnloopbackIfTable 1}

NnLoopbackIfTableEntry ::= SEQUENCE {
        nnloopbackIfId		Integer32,
        nnloopbackIfName		DisplayString,
        nnloopbackIfIpAddr	IpAddress,
        nnloopbackIfSubnetMask	IpAddress,
        nnloopbackIfStatus	INTEGER,
        nnloopbackIfRowStatus	RowStatus
        }
nnloopbackIfId            OBJECT-TYPE
        SYNTAX          Integer32 
        MAX-ACCESS      not-accessible  
        STATUS          current
        DESCRIPTION     "loopbackIfId is the identifier of a loopback
			Interface. To configure a loopback, this 
			parameter must be used as the index. This is 
			assigned internally by the system. Whenever a 
			row creation needs to occur in the 
			loopbackIfTable, the loopbackIfId is entered 
			as 65535."
        ::= { nnloopbackIfTableEntry 1}

nnloopbackIfName          OBJECT-TYPE
        SYNTAX          DisplayString (SIZE (1..8))
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "Name of the loopback If. To configure a 
			loopback Interface,this parameter must be set.
			That is, a descriptive name should be given to
			a loopback inteface. The maximum length of a 
			name is 8 characters. This parameter is set 
			once during the creation of a loopback If. 
			A loopback can not be renamed." 
        ::= { nnloopbackIfTableEntry 2}
nnloopbackIfIpAddr        OBJECT-TYPE
        SYNTAX          IpAddress
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "The loopback's source IP address. This is one 
                        of the parameters required to set up loopback
			interface. The parameters loopbackIfIpAddr 
                        and loopbackIfSubnetMask have to be set 
			together during the same request. 
			To unconfigure the IP address, a set operation
			is performed with the value 0.0.0.0" 
        DEFVAL          { 0 }  
        ::= { nnloopbackIfTableEntry 3}

nnloopbackIfSubnetMask    OBJECT-TYPE
        SYNTAX          IpAddress
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "This parameter represents the source subnet 
                        mask address. This is one of the parameters 
                        required to set up loopback interface. 
                        This parameter is set along with the 
                        loopbackIfIpAddr parameter during the same 
                        request." 
        DEFVAL          { 0 }  
        ::= { nnloopbackIfTableEntry 4}

nnloopbackIfStatus        OBJECT-TYPE
        SYNTAX      INTEGER {
                        up(1),
                        down(2)
                    }
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION     "loopbackIfStatus shows the current status
			of the loopback interface."
        DEFVAL          { up }
        ::= { nnloopbackIfTableEntry 5 }

nnloopbackIfRowStatus OBJECT-TYPE
        SYNTAX          RowStatus
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION     "loopbackIfRowStatus is used to add/delete a 
			row  In the table. Adding or deleting a row 
                        corresponds to creating a loopback or deleting
                        a loopback. In order to add a row to the 
			loopback table, a set on this parameter should
			be done with the value 4 (createAndGo) and 
                        loopbackIfId parameter set with the value 
			of 65535. 
 			A request to create a row can be 
                        completed successfully only if a set on the 
                        loopbackIfRowStatus and a set on the 
			loopbackIfName come in the same request. 
			To delete a row this parameter has to be set
			with the value 6
                        (destroy)." 
        ::= { nnloopbackIfTableEntry 6}

-- TRAP definitions for the Bundle Up/Down status
--
--
nnbundleTraps  OBJECT IDENTIFIER ::= { nnbundleMib 5}
nnbundleNotifications  OBJECT IDENTIFIER ::= {nnbundleTraps 0}
nnbundleTrapVariables  OBJECT IDENTIFIER  ::= {nnbundleTraps 1}

nnenableBundleUpDownNotification 	OBJECT-TYPE
    	SYNTAX          		TruthValue
    	MAX-ACCESS      		read-write
    	STATUS          		current
    	DESCRIPTION
               "Indicates whether the system produces the
                BundleDownTrap & BundleUpTrap . The default is yes.
                "
 	DEFVAL { true }
    	::= { nnbundleTraps 2 }

nnbundleNameStr       OBJECT-TYPE
        SYNTAX          DisplayString (SIZE (1..8))
        MAX-ACCESS      accessible-for-notify
        STATUS          current
        DESCRIPTION     "Name of the bundle going UP/DOWN.
                        " 
        ::= { nnbundleTrapVariables 1}

nnbundleDownCause   OBJECT-TYPE
    SYNTAX  INTEGER {
                admin-delete (1),
                admin-down (2),
                l1-failures (3),
                l2-negotiation-fail (4),
                bcp-negotiation-fail (5),
                l3-negotiation-fail (6),
                bundle-track-down (7)
                }
        MAX-ACCESS  accessible-for-notify
        STATUS  current
        DESCRIPTION
             "Reason for the bundle going down
                admin_delete - bundle has been deleted by administrator,
                admin_down - bundle has been disabled administratively,
                l1-failure - Layer 1 failures (physical links), 
			including physical alarms, errors,etc. If a bundle
			is a multilink bundle, then the bundle will go down
			if all the inks go down. In case of MFR 
			bundles, bundles behave according to the 
			bandwidth class settings.
                l2-failure - Layer 2 related failures: LCP for PPP and  
			LMI for FR bundles.
                bcp-negotiation-fail - BCP negotiation failures on PPP bundles.
                l3-failure - Layer 3 related failures. NCP for PPP. Incase of 
			FR bundles, the layer 3 negotiation failures 
			will not bring the bundle down.
                bundle-track-down - Bundle is disabled by bundle tracking,
                "
        ::= { nnbundleTrapVariables 2}

nnbundleContactInfo       OBJECT-TYPE
        SYNTAX          DisplayString (SIZE (1..15))
        MAX-ACCESS      accessible-for-notify
        STATUS          current
        DESCRIPTION     "Name of the person who can be contacted 
                        for information about the bundle.
			"
        ::= { nnbundleTrapVariables 3}

nnbundleDescrInfo         OBJECT-TYPE
        SYNTAX          DisplayString (SIZE (1..25))
        MAX-ACCESS      accessible-for-notify
        STATUS          current
        DESCRIPTION     "Brief description of the bundle.
			"
        ::= { nnbundleTrapVariables 4}

nnbundleDownTrap NOTIFICATION-TYPE
        OBJECTS {
                nnbundleNameStr,
                nnbundleDownCause,
                nnbundleContactInfo,
                nnbundleDescrInfo       
                } 

	STATUS current

        DESCRIPTION
             "Trap being generated when a bundle goes down."

       ::= {nnbundleNotifications 1}

nnbundleUpTrap NOTIFICATION-TYPE
        OBJECTS {
	       nnbundleNameStr,
        	nnbundleContactInfo,
          	nnbundleDescrInfo
	}
        STATUS current

        DESCRIPTION
             "Trap being generated when a bundle comes up."
        ::= {nnbundleNotifications 2}

-- TRAP definitions for the Link Up/Down status
--
--
nnenableLinkUpDownNotification 	OBJECT-TYPE
    	SYNTAX          		TruthValue
    	MAX-ACCESS      		read-write
    	STATUS          		current
    	DESCRIPTION
               "Indicates whether the system produces the
                linkDownTrap & linkUpTrap . The default is yes.
                "
 	DEFVAL { true }
    	::= { nnbundleTraps 3 }

nnlinkNum     OBJECT-TYPE
        SYNTAX          DisplayString (SIZE (1..15))
        MAX-ACCESS      accessible-for-notify
        STATUS          current
        DESCRIPTION     "linkNum is the number of the T1/E1 link.
                        "      
       ::= { nnbundleTrapVariables 5 }

nnlinkType      OBJECT-TYPE
        SYNTAX		INTEGER {
				t1(1),
				t1-within-ct3(2),
				e1(3),
				e1-within-ce3(4),
				t3(5),
				hssi(6),
				v35(7),
				ft1(8),
				fe1(9),
				x21(10),
				s530(11),
				s530A(12),
				s449(13),
				s232(14)
                        }
        MAX-ACCESS      accessible-for-notify
        STATUS          current
        DESCRIPTION     "linkType specifies the interface type 
                        (i.e., CT3, T1, FT1, T3, E1, FE1, v35 and HSSI) of the link.
                        " 
        ::= { nnbundleTrapVariables 6 }

nnlinkCt3Num OBJECT-TYPE
        SYNTAX          DisplayString (SIZE (1..15))
        MAX-ACCESS      accessible-for-notify
        STATUS          current
        DESCRIPTION     "linkCt3Num specifies the interface
                        number of the CT3/CE3 interface.
                        This variable holds significance only for 
                        link type  t1-within-ct3 and e1-within-ce3.
			"
        ::= { nnbundleTrapVariables 7 }

nnlinkDownCause   OBJECT-TYPE
    SYNTAX  INTEGER {
                admin-delete (1),
                admin-down (2),
                drop-config (3),
                diffdelay (4),
                l1-failures (5)
                }
        MAX-ACCESS  accessible-for-notify
        STATUS  current
        DESCRIPTION
             "Reason for the bundle going down
                admin-delete - link has been removed/deleted from the 
			bundle by the administrator,
                admin-down - physical link has been disabled administratively
			from module configuration commands, 
			e.g. 'no enable t1 1'
                drop-config - link has been removed from the bundle due to 
			event being triggered by the error threshold 
			configuration for the link. e.g. 'drop es 10'
			command setting from the bundle configuration
			commands.
                l1-failure - Layer 1 failures (physical links), including 
			physical alarms, excessive errors,etc.
                "
        ::= { nnbundleTrapVariables 8}

nnlinkBundleName          OBJECT-TYPE
        SYNTAX          DisplayString (SIZE(0..8))
        MAX-ACCESS      accessible-for-notify
        STATUS          current
        DESCRIPTION     "Name of the bundle in which the link belongs to.
                        " 
        ::= { nnbundleTrapVariables 9 }

nnlinkCircuitId  OBJECT-TYPE
    SYNTAX         DisplayString (SIZE(0..64))
    MAX-ACCESS    accessible-for-notify 
    STATUS         current
    DESCRIPTION    "Configured cuircuit Id of the link"
    ::= { nnbundleTrapVariables 10}

nnlinkContactInfo  OBJECT-TYPE
    SYNTAX            DisplayString (SIZE(0..64))
    MAX-ACCESS       accessible-for-notify 
    STATUS            current
    DESCRIPTION       "Configured contact string of the link"
    ::= { nnbundleTrapVariables 11}

nnlinkNameInfo          OBJECT-TYPE
        SYNTAX          DisplayString (SIZE(0..16))
        MAX-ACCESS     accessible-for-notify 
        STATUS          current
        DESCRIPTION     "Name of the link"
        ::= { nnbundleTrapVariables 12 }

nnlinkDescrInfo         OBJECT-TYPE
        SYNTAX          DisplayString (SIZE (1..25))
        MAX-ACCESS     accessible-for-notify 
        STATUS          current
        DESCRIPTION     "Brief description of link"
        ::= { nnbundleTrapVariables 13 }

nnlinkDownTrap NOTIFICATION-TYPE
        OBJECTS {
		nnlinkNum,
		nnlinkType,
		nnlinkCt3Num,
		nnlinkDownCause,
		nnlinkBundleName,
		nnlinkCircuitId,
		nnlinkContactInfo,
		nnlinkNameInfo,
		nnlinkDescrInfo
	}
       STATUS current
        DESCRIPTION
             "Trap being generated when a link from a bundle goes down."
        ::= {nnbundleNotifications 3}

nnlinkUpTrap NOTIFICATION-TYPE

OBJECTS {
		nnlinkNum,
		nnlinkType,
		nnlinkCt3Num,
		nnlinkBundleName,
		nnlinkCircuitId,
		nnlinkContactInfo,
		nnlinkNameInfo,
		nnlinkDescrInfo
	}
 STATUS current
        DESCRIPTION
             "Trap being generated when a link whihin a bundle comes up."
        ::= {nnbundleNotifications 4}
nnbundleNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS {
		nnbundleDownTrap,
		nnbundleUpTrap,
		nnlinkDownTrap,
		nnlinkUpTrap 
	      }

	  STATUS current
	  DESCRIPTION
	  "The BUNDLE MIB Notification Group."
	  ::={nnbundleMib 6}

END