NETI-PM-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, Gauge32, Counter32, Unsigned32
        FROM SNMPv2-SMI
 
    TEXTUAL-CONVENTION, DisplayString, TruthValue, DateAndTime
        FROM SNMPv2-TC

    OBJECT-GROUP
        FROM SNMPv2-CONF

    netiExperimentalGeneric
        FROM NETI-COMMON-MIB;


netiPMMIB MODULE-IDENTITY
    LAST-UPDATED
        "200812121200Z"    
    ORGANIZATION
        "Net Insight AB"
    CONTACT-INFO
        "Net Insight AB
        Box 42093
        SE-126 14 Stockholm
        Sweden
        Tel +46-8-685 0400
        info@netinsight.net"
    DESCRIPTION
        "The Net Insight PM (Performance Monitoring) MIB. The MIB
         implements objects for monitoring the performance of trunk
         interfaces, access interfaces and channels according to
         G.826."

    REVISION
        "200812121200Z"    
    DESCRIPTION
        "Added tables for 24 hour current data. These tables are:
         pmTif24hCurrentTable, pmAif24hCurrentTable and
         mDch24hCurrentTable.

         Fixed imports.

         Changed index of type Integer32 to Unsigned32."

     
::= { netiExperimentalGeneric 17 }

netiPMMIBObjects OBJECT IDENTIFIER ::= { netiPMMIB 1 }


-- -------------------------------------------------------------
-- Groups in the NETI-PM-MIB
-- -------------------------------------------------------------

pmTifGroup           OBJECT IDENTIFIER ::= { netiPMMIBObjects 1 }
pmAifGroup           OBJECT IDENTIFIER ::= { netiPMMIBObjects 2 }
pmDchGroup           OBJECT IDENTIFIER ::= { netiPMMIBObjects 3 }
pmConformanceGroups  OBJECT IDENTIFIER ::= { netiPMMIBObjects 4 }


-- -------------------------------------------------------------
-- Textual Conventions
-- -------------------------------------------------------------
Counter15m ::= TEXTUAL-CONVENTION
    STATUS  current
    DESCRIPTION
        "" 
    SYNTAX  Unsigned32 (0..910)

Counter24h ::= TEXTUAL-CONVENTION
    STATUS  current
    DESCRIPTION
        "" 
    SYNTAX  Unsigned32 (0..86410)

-- -----------------------------------------------------------------
-- Performance data for trunk interfaces
-- -----------------------------------------------------------------    

pmTifTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PmTifEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of Performance Monitored trunk interfaces"
    ::= { pmTifGroup 1 }

pmTifEntry OBJECT-TYPE
    SYNTAX      PmTifEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "One entry for each trunk interface"
    INDEX { pmTifIndex }
    ::= { pmTifTable 1}

PmTifEntry ::= SEQUENCE {
    pmTifIndex                    Unsigned32,
    pmTifAdminStatus              INTEGER,
    pmTifOperStatus               INTEGER,
    pmTifFailure                  DisplayString,
    pmTifDataSource               OBJECT IDENTIFIER,
    pmTifDataSourceName           DisplayString,
    pmTifUatAlarmsEnabled         TruthValue,
    pmTifTresholdAlarmsEnabled    TruthValue,
    pmTifPeriodicEventsEnabled    TruthValue,
    pmTifZeroSuppressionEnabled   TruthValue,
    pmTifHistorySize              INTEGER,
    pmTif15mTresholdES            Counter15m,
    pmTif15mTresholdSES           Counter15m,
    pmTif15mTresholdBBE           Gauge32,
    pmTif15mTresholdSS            Counter15m,
    pmTif24hTresholdES            Counter24h,
    pmTif24hTresholdSES           Counter24h,
    pmTif24hTresholdBBE           Gauge32,
    pmTif24hTresholdSS            Counter24h
}


pmTifIndex OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The index uniquely identifying this trunk interface."
    ::= { pmTifEntry 1 }

pmTifAdminStatus OBJECT-TYPE
    SYNTAX  INTEGER {
                up(1),
                down(2) }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
        "The desired state of the PM function. Affects the operative
         state of the PM object"
    ::= { pmTifEntry 2 }

pmTifOperStatus OBJECT-TYPE
    SYNTAX  INTEGER {
                 up(1),
                 down(2) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "PM operative state."
    ::= { pmTifEntry 3 }

pmTifFailure OBJECT-TYPE
    SYNTAX  DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Shows current failure state. An empty string indicates no
         failure"
    ::= { pmTifEntry 4 }

pmTifDataSource OBJECT-TYPE
    SYNTAX  OBJECT IDENTIFIER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The PM Data Source object"
    ::= { pmTifEntry 5 }

pmTifDataSourceName OBJECT-TYPE
    SYNTAX  DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The name of the PM Data Source"
    ::= { pmTifEntry 6 }


pmTifUatAlarmsEnabled OBJECT-TYPE
    SYNTAX  TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "If set to `true(1)' then UAT alarms will be sent.

         Unavailable time (UAT) defines a state where a service is
         unable to perform its normal task due to severe errors for a
         longer period. It begins at detection of ten consecutive SES
         events and ends at detection of ten consecutive non-SES
         events. In both cases, the 10s are considered part of
         unavailable respective available time and effects the
         visibility of G.826 PM events (they are delayed 10s)

         Entry and exit of UAT is declared by raising and clearing an
         UAT alarm (if enabled)"
    ::= { pmTifEntry 7 }

pmTifTresholdAlarmsEnabled OBJECT-TYPE
    SYNTAX  TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "If set to `true(1)' then threshold alarms will be sent.

         Each 15m and 24h current register counter can be assigned a
         threshold value. When crossed, a threshold crossing alarm
         will be sent for the interval if enabled. Raised alarm will
         be cleared at end of a following fault free interval i.e.
         one with all interval counter values below their threshold
         values and with no UAT. Only one TC alarm per interval can be
         raised, regardless of how many thresholds have been crossed."
    ::= { pmTifEntry 8 }

pmTifPeriodicEventsEnabled OBJECT-TYPE
    SYNTAX  TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "If set to `true(1)' then History Periodic Events will be sent."
    ::= { pmTifEntry 9 }

pmTifZeroSuppressionEnabled OBJECT-TYPE
    SYNTAX  TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "If set to `true(1)' then Zero Suppression mode is enabled

         Zero Suppression mode tells whether intervals with all
         current counters equal to zero shall be stored in the history
         log or not. If enabled, once a faulty interval is found, its
         current register content including a zero suppressed interval
         counter will be stored in the history log. The additional
         counter specifies how many fault free intervals have preceded
         the faulty one. In such way, history for a larger measurement
         period can be logged than would otherwise be possible"
    ::= { pmTifEntry 10 }

pmTifHistorySize OBJECT-TYPE
    SYNTAX  INTEGER {
                none(1),
                small(2),
                large(3) }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The size of the history log"
    ::= { pmTifEntry 11 }

pmTif15mTresholdES OBJECT-TYPE
    SYNTAX  Counter15m
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "15 minute threshold value for ES.

         Current ES value equal to or above this threshold will raise
         a threshold alarm if enabled. A value of zero will disable
         threshold check."
    ::= { pmTifEntry 12 }

pmTif15mTresholdSES OBJECT-TYPE
    SYNTAX  Counter15m
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "15 minute threshold value for SES.

         Current SES value equal to or above this threshold will raise
         a threshold alarm if enabled. A value of zero will disable
         threshold check."
    ::= { pmTifEntry 13 }

pmTif15mTresholdBBE OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "15 minute threshold value for BBE.

         Current BBE value equal to or above this threshold will raise
         a threshold alarm if enabled. A value of zero will disable
         threshold check."
    ::= { pmTifEntry 14 }

pmTif15mTresholdSS OBJECT-TYPE
    SYNTAX  Counter15m
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "15 minute threshold value for SS.

         Current SS value equal to or above this threshold will raise
         a threshold alarm if enabled. A value of zero will disable
         threshold check."
    ::= { pmTifEntry 15 }

pmTif24hTresholdES OBJECT-TYPE
    SYNTAX  Counter24h
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "24 hour threshold value for ES.

         Current ES value equal to or above this threshold will raise
         a threshold alarm if enabled. A value of zero will disable
         threshold check."
    ::= { pmTifEntry 16 }

pmTif24hTresholdSES OBJECT-TYPE
    SYNTAX  Counter24h
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "24 hour threshold value for SES.

         Current SES value equal to or above this threshold will raise
         a threshold alarm if enabled. A value of zero will disable
         threshold check."
    ::= { pmTifEntry 17 }

pmTif24hTresholdBBE OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "24 hour threshold value for BBE.

         Current BBE value equal to or above this threshold will raise
         a threshold alarm if enabled. A value of zero will disable
         threshold check."
    ::= { pmTifEntry 18 }

pmTif24hTresholdSS OBJECT-TYPE
    SYNTAX  Counter24h
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "24 hour threshold value for SS.

         Current SS value equal to or above this threshold will raise
         a threshold alarm if enabled. A value of zero will disable
         threshold check."
    ::= { pmTifEntry 19 }


-- 15 minute current

pmTifCurrentTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PmTifCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of PM data for the current 15 minute period"
    ::= { pmTifGroup 2 }

pmTifCurrentEntry OBJECT-TYPE
    SYNTAX      PmTifCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "One entry for each monitored object"
    INDEX { pmTifIndex }
    ::= { pmTifCurrentTable 1}

PmTifCurrentEntry ::= SEQUENCE {
    pmTifCurrentTime      Counter15m,
    pmTifCurrentSuspect   TruthValue,
    pmTifCurrentZS        Counter32,
    pmTifCurrentESs       Counter15m,
    pmTifCurrentSESs      Counter15m,
    pmTifCurrentBBEs      Gauge32,
    pmTifCurrentUASs      Counter15m,
    pmTifCurrentSSs       Counter15m
}

pmTifCurrentTime OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Elapsed time in seconds for the current 15 minute period."
    ::= { pmTifCurrentEntry 2 }

pmTifCurrentSuspect OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Is Suspect flag, if set to `true(1)' the current 15 minute
         measurement period has unreliable measurement data."
    ::= { pmTifCurrentEntry 3 }

pmTifCurrentZS OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Zero Suppression Counter.

         If the performance monitoring uses zero suppression, this
         counter specifies how many fault free intervals have preceded
         the faulty one."
    ::= { pmTifCurrentEntry 4 }

pmTifCurrentESs OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Errored Seconds (ES) for the current 15 minute
         period.

         ES is defined as one second of available time containing one
         or more Errored Blocks (EB) or at least one defect"
    ::= { pmTifCurrentEntry 5 }

pmTifCurrentSESs OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Severe Errored Seconds (SES) for the current 15
         minute period.

         SES is defined as one second of available time containing
         more than 30% Errored Blocks (EB) or at least one defect."
    ::= { pmTifCurrentEntry 6 }

pmTifCurrentBBEs OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Background Block Error (BBE) for the current 15 minute period.

        BBE is defined as the number of Errored Blocks (EB) during one second 
        of available time not part of SES"
    ::= { pmTifCurrentEntry 7 }

pmTifCurrentUASs OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Unavailable Second (UAS) for the current 15 minute
         period.

         UAS is defined as one second of UAT (Unavailable
         Time). During UAT calculations of BBE, ES and SES are
         inhibited and no data collection of them is performed"
    ::= { pmTifCurrentEntry 8 }

pmTifCurrentSSs OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of SLIP Second (SS) for the current 15 minute period.

         SS is defined as one second containing one or more SLIPs"
    ::= { pmTifCurrentEntry 9 }


-- 15 minute history

pmTif15mTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PmTif15mEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of 15 minute PM log history"
    ::= { pmTifGroup 3 }

pmTif15mEntry OBJECT-TYPE
    SYNTAX      PmTif15mEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "One entry for each 15 minute PM interval"
    INDEX { pmTifIndex, pmTif15mIndex }
    ::= { pmTif15mTable 1}


PmTif15mEntry ::= SEQUENCE {
    pmTif15mIndex     Unsigned32,
    pmTif15mTime      DateAndTime,
    pmTif15mSuspect   TruthValue,
    pmTif15mZS        Counter32,
    pmTif15mESs       Counter15m,
    pmTif15mSESs      Counter15m,
    pmTif15mBBEs      Gauge32,
    pmTif15mUASs      Counter15m,
    pmTif15mSSs       Counter15m
}

pmTif15mIndex OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The index that identifies the interval for which the set of
         statistics is available. Index of '0' indicates the most
         recently completed interval, and the index is increased by
         one for each interval back in time."
    ::= { pmTif15mEntry 1 }

pmTif15mTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Time stamp for this 15 minute interval"
    ::= { pmTif15mEntry 2 }

pmTif15mSuspect OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Suspect flag for this 15 minute interval"
    ::= { pmTif15mEntry 3 }

pmTif15mZS OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Zero Suppression Counter.

         If the performance monitoring uses zero suppression, this
         counter specifies how many fault free intervals have preceded
         the faulty one."
    ::= { pmTif15mEntry 4 }

pmTif15mESs OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Errored Seconds (ES) for this 15 minute period.

         ES is defined as one second of available time containing one
         or more Errored Blocks (EB) or at least one defect"
    ::= { pmTif15mEntry 5 }

pmTif15mSESs OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Severe Errored Seconds (SES) for this 15 minute
         period.

         SES is defined as one second of available time containing
         more than 30% Errored Blocks (EB) or at least one defect."
    ::= { pmTif15mEntry 6 }

pmTif15mBBEs OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Background Block Error (BBE) for this 15 minute
         period.

         BBE is defined as the number of Errored Blocks (EB) during
         one second of available time not part of SES"
    ::= { pmTif15mEntry 7 }

pmTif15mUASs OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Unavailable Second (UAS) for this 15 minute period.

         UAS is defined as one second of UAT (Unavailable
         Time). During UAT calculations of BBE, ES and SES are
         inhibited and no data collection of them is performed"
    ::= { pmTif15mEntry 8 }

pmTif15mSSs OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of SLIP Second (SS) for this 15 minute period.

         SS is defined as one second containing one or more SLIPs"
    ::= { pmTif15mEntry 9 }


-- 24 hour history

pmTif24hTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PmTif24hEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of 24 hour PM log history"
    ::= { pmTifGroup 4 }

pmTif24hEntry OBJECT-TYPE
    SYNTAX      PmTif24hEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "One entry for each 24 hour PM interval"
    INDEX { pmTifIndex, pmTif24hIndex }
    ::= { pmTif24hTable 1}


PmTif24hEntry ::= SEQUENCE {
    pmTif24hIndex     Unsigned32,
    pmTif24hTime      DateAndTime,
    pmTif24hSuspect   TruthValue,
    pmTif24hZS        Counter32,
    pmTif24hESs       Counter24h,
    pmTif24hSESs      Counter24h,
    pmTif24hBBEs      Gauge32,
    pmTif24hUASs      Counter24h,
    pmTif24hSSs       Counter24h
}

pmTif24hIndex OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The index that identifies the interval for which the set of
         statistics is available. Index of '0' indicates the most
         recently completed interval, and the index is increased by
         one for each interval back in time."
    ::= { pmTif24hEntry 1 }

pmTif24hTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Time stamp for this 24 hour interval"
    ::= { pmTif24hEntry 2 }

pmTif24hSuspect OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Suspect flag for this 24 hour interval"
    ::= { pmTif24hEntry 3 }

pmTif24hZS OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Zero Suppression Counter.

         If the performance monitoring uses zero suppression, this
         counter specifies how many fault free intervals have preceded
         the faulty one."
    ::= { pmTif24hEntry 4 }

pmTif24hESs OBJECT-TYPE
    SYNTAX      Counter24h
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Errored Seconds (ES) for this 24 hour period.

         ES is defined as one second of available time containing one
         or more Errored Blocks (EB) or at least one defect"
    ::= { pmTif24hEntry 5 }

pmTif24hSESs OBJECT-TYPE
    SYNTAX      Counter24h
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Severe Errored Seconds (SES) for this 24 hour
         period.

         SES is defined as one second of available time containing
         more than 30% Errored Blocks (EB) or at least one defect."
    ::= { pmTif24hEntry 6 }

pmTif24hBBEs OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Background Block Error (BBE) for this 24 hour
         period.

         BBE is defined as the number of Errored Blocks (EB) during
         one second of available time not part of SES"
    ::= { pmTif24hEntry 7 }

pmTif24hUASs OBJECT-TYPE
    SYNTAX      Counter24h
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Unavailable Second (UAS) for this 24 hour period.

         UAS is defined as one second of UAT (Unavailable
         Time). During UAT calculations of BBE, ES and SES are
         inhibited and no data collection of them is performed"
    ::= { pmTif24hEntry 8 }

pmTif24hSSs OBJECT-TYPE
    SYNTAX      Counter24h
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of SLIP Second (SS) for this 24 hour period.

         SS is defined as one second containing one or more SLIPs"
    ::= { pmTif24hEntry 9 }


-- 24 hour current

pmTif24hCurrentTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PmTif24hCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION 
        "Table of PM data for the current 24 hour period"
    ::= { pmTifGroup 5 }

pmTif24hCurrentEntry OBJECT-TYPE
    SYNTAX      PmTif24hCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "One entry for each monitored object"
    INDEX { pmTifIndex }
    ::= { pmTif24hCurrentTable 1}


PmTif24hCurrentEntry ::= SEQUENCE {
    pmTif24hCurrentTime      Counter15m,
    pmTif24hCurrentSuspect   TruthValue,
    pmTif24hCurrentZS        Counter32,
    pmTif24hCurrentESs       Counter15m,
    pmTif24hCurrentSESs      Counter15m,
    pmTif24hCurrentBBEs      Gauge32,
    pmTif24hCurrentUASs      Counter15m,
    pmTif24hCurrentSSs       Counter15m
}

pmTif24hCurrentTime OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Elapsed time in seconds for the current 24 hour period."
    ::= { pmTif24hCurrentEntry 2 }

pmTif24hCurrentSuspect OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Is Suspect flag, if set to `true(1)' the current 24 hour
         measurement period has unreliable measurement data."
    ::= { pmTif24hCurrentEntry 3 }

pmTif24hCurrentZS OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Zero Suppression Counter.

         If the performance monitoring uses zero suppression, this
         counter specifies how many fault free intervals have preceded
         the faulty one."
    ::= { pmTif24hCurrentEntry 4 }

pmTif24hCurrentESs OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Errored Seconds (ES) for the current 24 hour
         period.

         ES is defined as one second of available time containing one
         or more Errored Blocks (EB) or at least one defect"
    ::= { pmTif24hCurrentEntry 5 }

pmTif24hCurrentSESs OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Severe Errored Seconds (SES) for the current 24
         hour period.

         SES is defined as one second of available time containing
         more than 30% Errored Blocks (EB) or at least one defect."
    ::= { pmTif24hCurrentEntry 6 }

pmTif24hCurrentBBEs OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Background Block Error (BBE) for the current 24
         hour period.

         BBE is defined as the number of Errored Blocks (EB) during
         one second of available time not part of SES"
    ::= { pmTif24hCurrentEntry 7 }

pmTif24hCurrentUASs OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Unavailable Second (UAS) for the current 24 hour
         period.

         UAS is defined as one second of UAT (Unavailable
         Time). During UAT calculations of BBE, ES and SES are
         inhibited and no data collection of them is performed"
    ::= { pmTif24hCurrentEntry 8 }

pmTif24hCurrentSSs OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of SLIP Second (SS) for the current 24 hour period.

         SS is defined as one second containing one or more SLIPs"
    ::= { pmTif24hCurrentEntry 9 }


-- -----------------------------------------------------------------
-- Performance data for access interfaces
-- -----------------------------------------------------------------    

pmAifTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PmAifEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of Performance Monitored access interfaces"
    ::= { pmAifGroup 1 }

pmAifEntry OBJECT-TYPE
    SYNTAX      PmAifEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "One entry for each access interface"
    INDEX { pmAifIndex }
    ::= { pmAifTable 1}

PmAifEntry ::= SEQUENCE {
    pmAifIndex                    Unsigned32,
    pmAifAdminStatus              INTEGER,
    pmAifOperStatus               INTEGER,
    pmAifFailure                  DisplayString,
    pmAifDataSource               OBJECT IDENTIFIER,
    pmAifDataSourceName           DisplayString,
    pmAifUatAlarmsEnabled         TruthValue,
    pmAifTresholdAlarmsEnabled    TruthValue,
    pmAifPeriodicEventsEnabled    TruthValue,
    pmAifZeroSuppressionEnabled   TruthValue,
    pmAifHistorySize              INTEGER,
    pmAif15mTresholdES            Counter15m,
    pmAif15mTresholdSES           Counter15m,
    pmAif15mTresholdBBE           Gauge32,
    pmAif24hTresholdES            Counter24h,
    pmAif24hTresholdSES           Counter24h,
    pmAif24hTresholdBBE           Gauge32
}

pmAifIndex OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The index uniquely identifying this access interface."
    ::= { pmAifEntry 1 }

pmAifAdminStatus OBJECT-TYPE
    SYNTAX  INTEGER {
    up(1),
    down(2)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
        "The desired state of the PM function. Affects the operative
         state of the PM object"
    ::= { pmAifEntry 2 }

pmAifOperStatus OBJECT-TYPE
    SYNTAX  INTEGER {
                up(1),
                down(2) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "PM operative state."
    ::= { pmAifEntry 3 }

pmAifFailure OBJECT-TYPE
    SYNTAX  DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Shows current failure state. An empty string indicates no
         failure"
    ::= { pmAifEntry 4 }

pmAifDataSource OBJECT-TYPE
    SYNTAX  OBJECT IDENTIFIER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The PM Data Source object"
    ::= { pmAifEntry 5 }

pmAifDataSourceName OBJECT-TYPE
    SYNTAX  DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The name of the PM Data Source"
    ::= { pmAifEntry 6 }

pmAifUatAlarmsEnabled OBJECT-TYPE
    SYNTAX  TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "If set to `true(1)' then UAT alarms will be sent.

         Unavailable time (UAT) defines a state where a service is
         unable to perform its normal task due to severe errors for a
         longer period. It begins at detection of ten consecutive SES
         events and ends at detection of ten consecutive non-SES
         events. In both cases, the 10s are considered part of
         unavailable respective available time and effects the
         visibility of G.826 PM events (they are delayed 10s)

         Entry and exit of UAT is declared by raising and clearing an
         UAT alarm (if enabled)"
    ::= { pmAifEntry 7 }

pmAifTresholdAlarmsEnabled OBJECT-TYPE
    SYNTAX  TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "If set to `true(1)' then threshold alarms will be sent.

         Each 15m and 24h current register counter can be assigned a
         threshold value. When crossed, a threshold crossing alarm
         will be sent for the interval if enabled. Raised alarm will
         be cleared at end of a following fault free interval i.e.
         one with all interval counter values below their threshold
         values and with no UAT. Only one TC alarm per interval can be
         raised, regardless of how many thresholds have been crossed."
    ::= { pmAifEntry 8 }

pmAifPeriodicEventsEnabled OBJECT-TYPE
    SYNTAX  TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "If set to `true(1)' then History Periodic Events will be
         sent."
    ::= { pmAifEntry 9 }

pmAifZeroSuppressionEnabled OBJECT-TYPE
    SYNTAX  TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "If set to `true(1)' then Zero Suppression mode is enabled

         Zero Suppression mode tells whether intervals with all
         current counters equal to zero shall be stored in the history
         log or not. If enabled, once a faulty interval is found, its
         current register content including a zero suppressed interval
         counter will be stored in the history log. The additional
         counter specifies how many fault free intervals have preceded
         the faulty one. In such way, history for a larger measurement
         period can be logged than would otherwise be possible"
    ::= { pmAifEntry 10 }

pmAifHistorySize OBJECT-TYPE
    SYNTAX  INTEGER {
                none(1),
                small(2),
                large(3) }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The size of the history log"
    ::= { pmAifEntry 11 }

pmAif15mTresholdES OBJECT-TYPE
    SYNTAX  Counter15m
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "15 minute threshold value for ES.

         Current ES value equal to or above this threshold will raise
         a threshold alarm if enabled. A value of zero will disable
         threshold check."
    ::= { pmAifEntry 12 }

pmAif15mTresholdSES OBJECT-TYPE
    SYNTAX  Counter15m
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "15 minute threshold value for SES.

         Current SES value equal to or above this threshold will raise
         a threshold alarm if enabled. A value of zero will disable
         threshold check."
    ::= { pmAifEntry 13 }

pmAif15mTresholdBBE OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "15 minute threshold value for BBE.

         Current BBE value equal to or above this threshold will raise
         a threshold alarm if enabled. A value of zero will disable
         threshold check."
    ::= { pmAifEntry 14 }

pmAif24hTresholdES OBJECT-TYPE
    SYNTAX  Counter24h
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "24 hour threshold value for ES.

         Current ES value equal to or above this threshold will raise
         a threshold alarm if enabled. A value of zero will disable
         threshold check."
    ::= { pmAifEntry 15 }

pmAif24hTresholdSES OBJECT-TYPE
    SYNTAX  Counter24h
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "24 hour threshold value for SES.

         Current SES value equal to or above this threshold will raise
         a threshold alarm if enabled. A value of zero will disable
         threshold check."
    ::= { pmAifEntry 16 }

pmAif24hTresholdBBE OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "24 hour threshold value for BBE.

         Current BBE value equal to or above this threshold will raise
         a threshold alarm if enabled. A value of zero will disable
         threshold check."
    ::= { pmAifEntry 17 }


-- 15 miunte current

pmAifCurrentTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PmAifCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of PM data for the current 15 minute period"
    ::= { pmAifGroup 2 }

pmAifCurrentEntry OBJECT-TYPE
    SYNTAX      PmAifCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "One entry for each monitored object"
    INDEX { pmAifIndex }
    ::= { pmAifCurrentTable 1}

PmAifCurrentEntry ::= SEQUENCE {
    pmAifCurrentTime      Counter15m,
    pmAifCurrentSuspect   TruthValue,
    pmAifCurrentZS        Counter32,
    pmAifCurrentESs       Counter15m,
    pmAifCurrentSESs      Counter15m,
    pmAifCurrentBBEs      Gauge32,
    pmAifCurrentUASs      Counter15m
}

pmAifCurrentTime OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Elapsed time in seconds for the current 15 minute period."
    ::= { pmAifCurrentEntry 2 }

pmAifCurrentSuspect OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Is Suspect flag, if set to `true(1)' the current 15 minute
         measurement period has unreliable measurement data."
    ::= { pmAifCurrentEntry 3 }

pmAifCurrentZS OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Zero Suppression Counter.

         If the performance monitoring uses zero suppression, this
         counter specifies how many fault free intervals have preceded
         the faulty one."
    ::= { pmAifCurrentEntry 4 }

pmAifCurrentESs OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Errored Seconds (ES) for the current 15 minute
         period.

         ES is defined as one second of available time containing one
         or more Errored Blocks (EB) or at least one defect"
    ::= { pmAifCurrentEntry 5 }

pmAifCurrentSESs OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Severe Errored Seconds (SES) for the current 15
         minute period.

         SES is defined as one second of available time containing
         more than 30% Errored Blocks (EB) or at least one defect."
    ::= { pmAifCurrentEntry 6 }

pmAifCurrentBBEs OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Background Block Error (BBE) for the current 15
         minute period.

         BBE is defined as the number of Errored Blocks (EB) during
         one second of available time not part of SES"
    ::= { pmAifCurrentEntry 7 }

pmAifCurrentUASs OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Unavailable Second (UAS) for the current 15 minute
         period.

         UAS is defined as one second of UAT (Unavailable
         Time). During UAT calculations of BBE, ES and SES are
         inhibited and no data collection of them is performed"
    ::= { pmAifCurrentEntry 8 }


-- 15 minute history

pmAif15mTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PmAif15mEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of 15 minute PM interval history"
    ::= { pmAifGroup 3 }

pmAif15mEntry OBJECT-TYPE
    SYNTAX      PmAif15mEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "One entry for each 15 minute PM interval"
    INDEX { pmAifIndex, pmAif15mIndex }
    ::= { pmAif15mTable 1}


PmAif15mEntry ::= SEQUENCE {
    pmAif15mIndex     Unsigned32,
    pmAif15mTime      DateAndTime,
    pmAif15mSuspect   TruthValue,
    pmAif15mZS        Counter32,
    pmAif15mESs       Counter15m,
    pmAif15mSESs      Counter15m,
    pmAif15mBBEs      Gauge32,
    pmAif15mUASs      Counter15m
}

pmAif15mIndex OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The index that identifies the interval for which the set of
         statistics is available. Index of '0' indicates the most
         recently completed interval, and the index is increased by
         one for each interval back in time."
    ::= { pmAif15mEntry 1 }

pmAif15mTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Time stamp for this 15 minute interval"
    ::= { pmAif15mEntry 2 }

pmAif15mSuspect OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Suspect flag for this 15 minute interval"
    ::= { pmAif15mEntry 3 }

pmAif15mZS OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Zero Suppression Counter.

         If the performance monitoring uses zero suppression, this
         counter specifies how many fault free intervals have preceded
         the faulty one."
    ::= { pmAif15mEntry 4 }

pmAif15mESs OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Errored Seconds (ES) for this 15 minute period.

         ES is defined as one second of available time containing one
         or more Errored Blocks (EB) or at least one defect"
    ::= { pmAif15mEntry 5 }

pmAif15mSESs OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Severe Errored Seconds (SES) for this 15 minute
         period.

         SES is defined as one second of available time containing
         more than 30% Errored Blocks (EB) or at least one defect."
    ::= { pmAif15mEntry 6 }

pmAif15mBBEs OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Background Block Error (BBE) for this 15 minute
         period.

         BBE is defined as the number of Errored Blocks (EB) during
         one second of available time not part of SES"
    ::= { pmAif15mEntry 7 }

pmAif15mUASs OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Unavailable Second (UAS) for this 15 minute period.

         UAS is defined as one second of UAT (Unavailable
         Time). During UAT calculations of BBE, ES and SES are
         inhibited and no data collection of them is performed"
    ::= { pmAif15mEntry 8 }


-- 24 hour history

pmAif24hTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PmAif24hEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of 24 hour PM log history"
    ::= { pmAifGroup 4 }

pmAif24hEntry OBJECT-TYPE
    SYNTAX      PmAif24hEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "One entry for each 24 hour PM interval"
    INDEX { pmAifIndex, pmAif24hIndex }
    ::= { pmAif24hTable 1}


PmAif24hEntry ::= SEQUENCE {
    pmAif24hIndex     Unsigned32,
    pmAif24hTime      DateAndTime,
    pmAif24hSuspect   TruthValue,
    pmAif24hZS        Counter32,
    pmAif24hESs       Counter24h,
    pmAif24hSESs      Counter24h,
    pmAif24hBBEs      Gauge32,
    pmAif24hUASs      Counter24h
}

pmAif24hIndex OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The index that identifies the interval for which the set of
         statistics is available. Index of '0' indicates the most
         recently completed interval, and the index is increased by
         one for each interval back in time."
    ::= { pmAif24hEntry 1 }

pmAif24hTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Time stamp for this 24 hour interval"
    ::= { pmAif24hEntry 2 }

pmAif24hSuspect OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Suspect flag for this 24 hour interval"
    ::= { pmAif24hEntry 3 }

pmAif24hZS OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Zero Suppression Counter.

         If the performance monitoring uses zero suppression, this
         counter specifies how many fault free intervals have preceded
         the faulty one."
    ::= { pmAif24hEntry 4 }

pmAif24hESs OBJECT-TYPE
    SYNTAX      Counter24h
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Errored Seconds (ES) for this 24 hour period.

         ES is defined as one second of available time containing one
         or more Errored Blocks (EB) or at least one defect"
    ::= { pmAif24hEntry 5 }

pmAif24hSESs OBJECT-TYPE
    SYNTAX      Counter24h
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Severe Errored Seconds (SES) for this 24 hour
         period.

         SES is defined as one second of available time containing
         more than 30% Errored Blocks (EB) or at least one defect."
    ::= { pmAif24hEntry 6 }

pmAif24hBBEs OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Background Block Error (BBE) for this 24 hour
         period.

         BBE is defined as the number of Errored Blocks (EB) during
         one second of available time not part of SES"
    ::= { pmAif24hEntry 7 }

pmAif24hUASs OBJECT-TYPE
    SYNTAX      Counter24h
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Unavailable Second (UAS) for this 24 hour period.

         UAS is defined as one second of UAT (Unavailable
         Time). During UAT calculations of BBE, ES and SES are
         inhibited and no data collection of them is performed"
    ::= { pmAif24hEntry 8 }


-- 24 hour current

pmAif24hCurrentTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PmAif24hCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of PM data for the current 24 hour period"
    ::= { pmAifGroup 5 }

pmAif24hCurrentEntry OBJECT-TYPE
    SYNTAX      PmAif24hCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "One entry for each monitored object"
    INDEX { pmAifIndex }
    ::= { pmAif24hCurrentTable 1}

PmAif24hCurrentEntry ::= SEQUENCE {
    pmAif24hCurrentTime      Counter15m,
    pmAif24hCurrentSuspect   TruthValue,
    pmAif24hCurrentZS        Counter32,
    pmAif24hCurrentESs       Counter15m,
    pmAif24hCurrentSESs      Counter15m,
    pmAif24hCurrentBBEs      Gauge32,
    pmAif24hCurrentUASs      Counter15m
}

pmAif24hCurrentTime OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Elapsed time in seconds for the current 24 hour period."
    ::= { pmAif24hCurrentEntry 2 }

pmAif24hCurrentSuspect OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Is Suspect flag, if set to `true(1)' the current 24 hour
         measurement period has unreliable measurement data."
    ::= { pmAif24hCurrentEntry 3 }

pmAif24hCurrentZS OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Zero Suppression Counter.

         If the performance monitoring uses zero suppression, this
         counter specifies how many fault free intervals have preceded
         the faulty one."
    ::= { pmAif24hCurrentEntry 4 }

pmAif24hCurrentESs OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Errored Seconds (ES) for the current 24 hour
         period.

         ES is defined as one second of available time containing one
         or more Errored Blocks (EB) or at least one defect"
    ::= { pmAif24hCurrentEntry 5 }

pmAif24hCurrentSESs OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Severe Errored Seconds (SES) for the current 24
         hour period.

         SES is defined as one second of available time containing
         more than 30% Errored Blocks (EB) or at least one defect."
    ::= { pmAif24hCurrentEntry 6 }

pmAif24hCurrentBBEs OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Background Block Error (BBE) for the current 24
         hour period.

         BBE is defined as the number of Errored Blocks (EB) during
         one second of available time not part of SES"
    ::= { pmAif24hCurrentEntry 7 }

pmAif24hCurrentUASs OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Unavailable Second (UAS) for the current 24 hour
         period.

         UAS is defined as one second of UAT (Unavailable
         Time). During UAT calculations of BBE, ES and SES are
         inhibited and no data collection of them is performed"
    ::= { pmAif24hCurrentEntry 8 }


-- -----------------------------------------------------------------
-- Performande data channels
-- -----------------------------------------------------------------    

pmDchTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PmDchEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of Performance Monitored DTM channel"
    ::= { pmDchGroup 1 }

pmDchEntry OBJECT-TYPE
    SYNTAX      PmDchEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "One entry for each DTM channel"
    INDEX { pmDchIndex }
    ::= { pmDchTable 1}

PmDchEntry ::= SEQUENCE {
    pmDchIndex                    Unsigned32,
    pmDchAdminStatus              INTEGER,
    pmDchOperStatus               INTEGER,
    pmDchFailure                  DisplayString,
    pmDchDataSource               OBJECT IDENTIFIER,
    pmDchDataSourceName           DisplayString,
    pmDchUatAlarmsEnabled         TruthValue,
    pmDchTresholdAlarmsEnabled    TruthValue,
    pmDchPeriodicEventsEnabled    TruthValue,
    pmDchZeroSuppressionEnabled   TruthValue,
    pmDchHistorySize              INTEGER,
    pmDch15mTresholdES            Counter15m,
    pmDch15mTresholdSES           Counter15m,
    pmDch15mTresholdBBE           Gauge32,
    pmDch24hTresholdES            Counter24h,
    pmDch24hTresholdSES           Counter24h,
    pmDch24hTresholdBBE           Gauge32
}

pmDchIndex OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The index uniquely identifying this DTM channel."
    ::= { pmDchEntry 1 }

pmDchAdminStatus OBJECT-TYPE
    SYNTAX  INTEGER {
    up(1),
    down(2)
    }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
        "The desired state of the PM function. Affects the operative
         state of the PM object"
    ::= { pmDchEntry 2 }

pmDchOperStatus OBJECT-TYPE
    SYNTAX  INTEGER {
                up(1),
                down(2) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "PM operative state."
    ::= { pmDchEntry 3 }

pmDchFailure OBJECT-TYPE
    SYNTAX  DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Shows current failure state. An empty string indicates no
         failure"
    ::= { pmDchEntry 4 }

pmDchDataSource OBJECT-TYPE
    SYNTAX  OBJECT IDENTIFIER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The PM Data Source object"
    ::= { pmDchEntry 5 }

pmDchDataSourceName OBJECT-TYPE
    SYNTAX  DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The name of the PM Data Source"
    ::= { pmDchEntry 6 }

pmDchUatAlarmsEnabled OBJECT-TYPE
    SYNTAX  TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "If set to `true(1)' then UAT alarms will be sent.

         Unavailable time (UAT) defines a state where a service is
         unable to perform its normal task due to severe errors for a
         longer period. It begins at detection of ten consecutive SES
         events and ends at detection of ten consecutive non-SES
         events. In both cases, the 10s are considered part of
         unavailable respective available time and effects the
         visibility of G.826 PM events (they are delayed 10s)

         Entry and exit of UAT is declared by raising and clearing an
         UAT alarm (if enabled)"
    ::= { pmDchEntry 7 }

pmDchTresholdAlarmsEnabled OBJECT-TYPE
    SYNTAX  TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "If set to `true(1)' then threshold alarms will be sent.

         Each 15m and 24h current register counter can be assigned a
         threshold value. When crossed, a threshold crossing alarm
         will be sent for the interval if enabled. Raised alarm will
         be cleared at end of a following fault free interval i.e.
         one with all interval counter values below their threshold
         values and with no UAT. Only one TC alarm per interval can be
         raised, regardless of how many thresholds have been crossed."
    ::= { pmDchEntry 8 }

pmDchPeriodicEventsEnabled OBJECT-TYPE
    SYNTAX  TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "If set to `true(1)' then History Periodic Events will be
        sent."
    ::= { pmDchEntry 9 }

pmDchZeroSuppressionEnabled OBJECT-TYPE
    SYNTAX  TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "If set to `true(1)' then Zero Suppression mode is enabled

         Zero Suppression mode tells whether intervals with all
         current counters equal to zero shall be stored in the history
         log or not. If enabled, once a faulty interval is found, its
         current register content including a zero suppressed interval
         counter will be stored in the history log. The additional
         counter specifies how many fault free intervals have preceded
         the faulty one. In such way, history for a larger measurement
         period can be logged than would otherwise be possible"
    ::= { pmDchEntry 10 }

pmDchHistorySize OBJECT-TYPE
    SYNTAX  INTEGER {
                none(1),
                small(2),
                large(3) }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The size of the history log"
    ::= { pmDchEntry 11 }

pmDch15mTresholdES OBJECT-TYPE
    SYNTAX  Counter15m
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "15 minute threshold value for ES.

         Current ES value equal to or above this threshold will raise
         a threshold alarm if enabled. A value of zero will disable
         threshold check."
    ::= { pmDchEntry 12 }

pmDch15mTresholdSES OBJECT-TYPE
    SYNTAX  Counter15m
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "15 minute threshold value for SES.

         Current SES value equal to or above this threshold will raise
         a threshold alarm if enabled. A value of zero will disable
         threshold check."
    ::= { pmDchEntry 13 }

pmDch15mTresholdBBE OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "15 minute threshold value for BBE.

         Current BBE value equal to or above this threshold will raise
         a threshold alarm if enabled. A value of zero will disable
         threshold check."
    ::= { pmDchEntry 14 }

pmDch24hTresholdES OBJECT-TYPE
    SYNTAX  Counter24h
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "24 hour threshold value for ES.

         Current ES value equal to or above this threshold will raise
         a threshold alarm if enabled. A value of zero will disable
         threshold check."
    ::= { pmDchEntry 15 }

pmDch24hTresholdSES OBJECT-TYPE
    SYNTAX  Counter24h
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "24 hour threshold value for SES.

         Current SES value equal to or above this threshold will raise
         a threshold alarm if enabled. A value of zero will disable
         threshold check."
    ::= { pmDchEntry 16 }

pmDch24hTresholdBBE OBJECT-TYPE
    SYNTAX  Gauge32
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "24 hour threshold value for BBE.

         Current BBE value equal to or above this threshold will raise
         a threshold alarm if enabled. A value of zero will disable
         threshold check."
    ::= { pmDchEntry 17 }


-- 15 minute current

pmDchCurrentTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PmDchCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of PM data for the current 15 minute period"
    ::= { pmDchGroup 2 }

pmDchCurrentEntry OBJECT-TYPE
    SYNTAX      PmDchCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "One entry for each monitored object"
    INDEX { pmDchIndex }
    ::= { pmDchCurrentTable 1}

PmDchCurrentEntry ::= SEQUENCE {
    pmDchCurrentTime      Counter15m,
    pmDchCurrentSuspect   TruthValue,
    pmDchCurrentZS        Counter32,
    pmDchCurrentESs       Counter15m,
    pmDchCurrentSESs      Counter15m,
    pmDchCurrentBBEs      Gauge32,
    pmDchCurrentUASs      Counter15m
}

pmDchCurrentTime OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Elapsed time in seconds for the current 15 minute period."
    ::= { pmDchCurrentEntry 2 }

pmDchCurrentSuspect OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Is Suspect flag, if set to `true(1)' the current 15 minute
         measurement period has unreliable measurement data."
    ::= { pmDchCurrentEntry 3 }

pmDchCurrentZS OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Zero Suppression Counter.

         If the performance monitoring uses zero suppression, this
         counter specifies how many fault free intervals have preceded
         the faulty one."
    ::= { pmDchCurrentEntry 4 }

pmDchCurrentESs OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Errored Seconds (ES) for the current 15 minute
         period.

         ES is defined as one second of available time containing one
         or more Errored Blocks (EB) or at least one defect"
    ::= { pmDchCurrentEntry 5 }

pmDchCurrentSESs OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Severe Errored Seconds (SES) for the current 15
         minute period.

         SES is defined as one second of available time containing
         more than 30% Errored Blocks (EB) or at least one defect."
    ::= { pmDchCurrentEntry 6 }

pmDchCurrentBBEs OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Background Block Error (BBE) for the current 15
         minute period.

         BBE is defined as the number of Errored Blocks (EB) during
         one second of available time not part of SES"
    ::= { pmDchCurrentEntry 7 }

pmDchCurrentUASs OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Unavailable Second (UAS) for the current 15 minute
         period.

         UAS is defined as one second of UAT (Unavailable
         Time). During UAT calculations of BBE, ES and SES are
         inhibited and no data collection of them is performed"
    ::= { pmDchCurrentEntry 8 }


-- 15 minute history

pmDch15mTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PmDch15mEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of 15 minute PM interval history"
    ::= { pmDchGroup 3 }

pmDch15mEntry OBJECT-TYPE
    SYNTAX      PmDch15mEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "One entry for each 15 minute PM interval"
    INDEX { pmDchIndex, pmDch15mIndex }
    ::= { pmDch15mTable 1}

PmDch15mEntry ::= SEQUENCE {
    pmDch15mIndex     Unsigned32,
    pmDch15mTime      DateAndTime,
    pmDch15mSuspect   TruthValue,
    pmDch15mZS        Counter32,
    pmDch15mESs       Counter15m,
    pmDch15mSESs      Counter15m,
    pmDch15mBBEs      Gauge32,
    pmDch15mUASs      Counter15m
}

pmDch15mIndex OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The index that identifies the interval for which the set of
         statistics is available. Index of '0' indicates the most
         recently completed interval, and the index is increased by
         one for each interval back in time."
    ::= { pmDch15mEntry 1 }

pmDch15mTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Time stamp for this 15 minute interval"
    ::= { pmDch15mEntry 2 }

pmDch15mSuspect OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Suspect flag for this 15 minute interval"
    ::= { pmDch15mEntry 3 }

pmDch15mZS OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Zero Suppression Counter.

         If the performance monitoring uses zero suppression, this
         counter specifies how many fault free intervals have preceded
         the faulty one."
    ::= { pmDch15mEntry 4 }

pmDch15mESs OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Errored Seconds (ES) for this 15 minute period.

         ES is defined as one second of available time containing one
         or more Errored Blocks (EB) or at least one defect"
    ::= { pmDch15mEntry 5 }

pmDch15mSESs OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Severe Errored Seconds (SES) for this 15 minute
         period.

         SES is defined as one second of available time containing
         more than 30% Errored Blocks (EB) or at least one defect."
    ::= { pmDch15mEntry 6 }

pmDch15mBBEs OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Background Block Error (BBE) for this 15 minute
         period.

         BBE is defined as the number of Errored Blocks (EB) during one
         second of available time not part of SES"
    ::= { pmDch15mEntry 7 }

pmDch15mUASs OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Unavailable Second (UAS) for this 15 minute period.

         UAS is defined as one second of UAT (Unavailable
         Time). During UAT calculations of BBE, ES and SES are
         inhibited and no data collection of them is performed"
    ::= { pmDch15mEntry 8 }


-- 24 hour history

pmDch24hTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PmDch24hEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of 24 hour PM interval history"
    ::= { pmDchGroup 4 }

pmDch24hEntry OBJECT-TYPE
    SYNTAX      PmDch24hEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "One entry for each 24 hour PM interval"
    INDEX { pmDchIndex, pmDch24hIndex }
    ::= { pmDch24hTable 1}

PmDch24hEntry ::= SEQUENCE {
    pmDch24hIndex     Unsigned32,
    pmDch24hTime      DateAndTime,
    pmDch24hSuspect   TruthValue,
    pmDch24hZS        Counter32,
    pmDch24hESs       Counter24h,
    pmDch24hSESs      Counter24h,
    pmDch24hBBEs      Gauge32,
    pmDch24hUASs      Counter24h
}

pmDch24hIndex OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The index that identifies the interval for which the set of
         statistics is available. Index of '0' indicates the most
         recently completed interval, and the index is increased by
         one for each interval back in time."
    ::= { pmDch24hEntry 1 }

pmDch24hTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Time stamp for this 24 hour interval"
    ::= { pmDch24hEntry 2 }

pmDch24hSuspect OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Suspect flag for this 24 hour interval"
    ::= { pmDch24hEntry 3 }

pmDch24hZS OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Zero Suppression Counter.

         If the performance monitoring uses zero suppression, this
         counter specifies how many fault free intervals have preceded
         the faulty one."
    ::= { pmDch24hEntry 4 }

pmDch24hESs OBJECT-TYPE
    SYNTAX      Counter24h
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Errored Seconds (ES) for this 24 hour period.

         ES is defined as one second of available time containing one
         or more Errored Blocks (EB) or at least one defect"
    ::= { pmDch24hEntry 5 }

pmDch24hSESs OBJECT-TYPE
    SYNTAX      Counter24h
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Severe Errored Seconds (SES) for this 24 hour
         period.

         SES is defined as one second of available time containing
         more than 30% Errored Blocks (EB) or at least one defect."
    ::= { pmDch24hEntry 6 }

pmDch24hBBEs OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Background Block Error (BBE) for this 24 hour
         period.

         BBE is defined as the number of Errored Blocks (EB) during
         one second of available time not part of SES"
    ::= { pmDch24hEntry 7 }

pmDch24hUASs OBJECT-TYPE
    SYNTAX      Counter24h
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Unavailable Second (UAS) for this 24 hour period.

         UAS is defined as one second of UAT (Unavailable
         Time). During UAT calculations of BBE, ES and SES are
         inhibited and no data collection of them is performed"
    ::= { pmDch24hEntry 8 }


-- 24 hour current

pmDch24hCurrentTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PmDch24hCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of PM data for the current 24 hour period"
    ::= { pmDchGroup 5 }

pmDch24hCurrentEntry OBJECT-TYPE
    SYNTAX      PmDch24hCurrentEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "One entry for each monitored object"
    INDEX { pmDchIndex }
    ::= { pmDch24hCurrentTable 1}


PmDch24hCurrentEntry ::= SEQUENCE {
    pmDch24hCurrentTime      Counter15m,
    pmDch24hCurrentSuspect   TruthValue,
    pmDch24hCurrentZS        Counter32,
    pmDch24hCurrentESs       Counter15m,
    pmDch24hCurrentSESs      Counter15m,
    pmDch24hCurrentBBEs      Gauge32,
    pmDch24hCurrentUASs      Counter15m
}

pmDch24hCurrentTime OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Elapsed time in seconds for the current 24 hour period."
    ::= { pmDch24hCurrentEntry 2 }

pmDch24hCurrentSuspect OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Is Suspect flag, if set to `true(1)' the current 24 hour
         measurement period has unreliable measurement data."
    ::= { pmDch24hCurrentEntry 3 }

pmDch24hCurrentZS OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Zero Suppression Counter.

         If the performance monitoring uses zero suppression, this
         counter specifies how many fault free intervals have preceded
         the faulty one."
    ::= { pmDch24hCurrentEntry 4 }

pmDch24hCurrentESs OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Errored Seconds (ES) for the current 24 hour
         period.

         ES is defined as one second of available time containing one
         or more Errored Blocks (EB) or at least one defect"
    ::= { pmDch24hCurrentEntry 5 }

pmDch24hCurrentSESs OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Severe Errored Seconds (SES) for the current 24
         hour period.

         SES is defined as one second of available time containing
         more than 30% Errored Blocks (EB) or at least one defect."
    ::= { pmDch24hCurrentEntry 6 }

pmDch24hCurrentBBEs OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Background Block Error (BBE) for the current 24
         hour period.

         BBE is defined as the number of Errored Blocks (EB) during
         one second of available time not part of SES"
    ::= { pmDch24hCurrentEntry 7 }

pmDch24hCurrentUASs OBJECT-TYPE
    SYNTAX      Counter15m
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of Unavailable Second (UAS) for the current 24 hour
         period.

         UAS is defined as one second of UAT (Unavailable
         Time). During UAT calculations of BBE, ES and SES are
         inhibited and no data collection of them is performed"
    ::= { pmDch24hCurrentEntry 8 }


-- -----------------------------------------------------------------
-- The PM Conformance Groups 
-- -----------------------------------------------------------------    
pmTifConformanceGroup OBJECT-GROUP
    OBJECTS {
    pmTifAdminStatus,    
    pmTifOperStatus,    
    pmTifFailure,    
    pmTifDataSource,    
    pmTifDataSourceName,    
    pmTifUatAlarmsEnabled,    
    pmTifTresholdAlarmsEnabled,    
    pmTifPeriodicEventsEnabled,    
    pmTifZeroSuppressionEnabled,    
    pmTifHistorySize,    
    pmTif15mTresholdES,    
    pmTif15mTresholdSES,    
    pmTif15mTresholdBBE,    
    pmTif15mTresholdSS,    
    pmTif24hTresholdES,    
    pmTif24hTresholdSES,    
    pmTif24hTresholdBBE,    
    pmTif24hTresholdSS,
    
    pmTifCurrentTime,
    pmTifCurrentSuspect,
    pmTifCurrentZS,
    pmTifCurrentESs,
    pmTifCurrentSESs,
    pmTifCurrentBBEs,
    pmTifCurrentUASs,
    pmTifCurrentSSs,
    
    pmTif15mTime,
    pmTif15mSuspect,
    pmTif15mZS,
    pmTif15mESs,
    pmTif15mSESs,
    pmTif15mBBEs,
    pmTif15mUASs,
    pmTif15mSSs,

    pmTif24hTime,
    pmTif24hSuspect,
    pmTif24hZS,
    pmTif24hESs,
    pmTif24hSESs,
    pmTif24hBBEs,
    pmTif24hUASs,
    pmTif24hSSs,

    pmTif24hCurrentTime,
    pmTif24hCurrentSuspect,
    pmTif24hCurrentZS,
    pmTif24hCurrentESs,
    pmTif24hCurrentSESs,
    pmTif24hCurrentBBEs,
    pmTif24hCurrentUASs,
    pmTif24hCurrentSSs    
    }
    
    STATUS current
    DESCRIPTION
        "The PM Trunk Interface Conformance Group."
    ::= { pmConformanceGroups 1 }




pmAifConformanceGroup OBJECT-GROUP
    OBJECTS {
    pmAifAdminStatus,    
    pmAifOperStatus,    
    pmAifFailure,    
    pmAifDataSource,    
    pmAifDataSourceName,    
    pmAifUatAlarmsEnabled,    
    pmAifTresholdAlarmsEnabled,    
    pmAifPeriodicEventsEnabled,    
    pmAifZeroSuppressionEnabled,    
    pmAifHistorySize,    
    pmAif15mTresholdES,    
    pmAif15mTresholdSES,    
    pmAif15mTresholdBBE,    
    pmAif24hTresholdES,    
    pmAif24hTresholdSES,    
    pmAif24hTresholdBBE,    
    
    pmAifCurrentTime,
    pmAifCurrentSuspect,
    pmAifCurrentZS,
    pmAifCurrentESs,
    pmAifCurrentSESs,
    pmAifCurrentBBEs,
    pmAifCurrentUASs,
    
    pmAif15mTime,
    pmAif15mSuspect,
    pmAif15mZS,
    pmAif15mESs,
    pmAif15mSESs,
    pmAif15mBBEs,
    pmAif15mUASs,
    
    pmAif24hTime,
    pmAif24hSuspect,
    pmAif24hZS,
    pmAif24hESs,
    pmAif24hSESs,
    pmAif24hBBEs,
    pmAif24hUASs,

    pmAif24hCurrentTime,
    pmAif24hCurrentSuspect,
    pmAif24hCurrentZS,
    pmAif24hCurrentESs,
    pmAif24hCurrentSESs,
    pmAif24hCurrentBBEs,
    pmAif24hCurrentUASs
    }
    
    STATUS current
    DESCRIPTION
        "The PM Access Interface Conformance Group."
    ::= { pmConformanceGroups 2 }



pmDchConformanceGroup OBJECT-GROUP
    OBJECTS {
    pmDchAdminStatus,    
    pmDchOperStatus,    
    pmDchFailure,    
    pmDchDataSource,    
    pmDchDataSourceName,    
    pmDchUatAlarmsEnabled,    
    pmDchTresholdAlarmsEnabled,    
    pmDchPeriodicEventsEnabled,    
    pmDchZeroSuppressionEnabled,    
    pmDchHistorySize,    
    pmDch15mTresholdES,    
    pmDch15mTresholdSES,    
    pmDch15mTresholdBBE,    
    pmDch24hTresholdES,    
    pmDch24hTresholdSES,    
    pmDch24hTresholdBBE,    
    
    pmDchCurrentTime,
    pmDchCurrentSuspect,
    pmDchCurrentZS,
    pmDchCurrentESs,
    pmDchCurrentSESs,
    pmDchCurrentBBEs,
    pmDchCurrentUASs,
    
    pmDch15mTime,
    pmDch15mSuspect,
    pmDch15mZS,
    pmDch15mESs,
    pmDch15mSESs,
    pmDch15mBBEs,
    pmDch15mUASs,
    
    pmDch24hTime,
    pmDch24hSuspect,
    pmDch24hZS,
    pmDch24hESs,
    pmDch24hSESs,
    pmDch24hBBEs,
    pmDch24hUASs,

    pmDch24hCurrentTime,
    pmDch24hCurrentSuspect,
    pmDch24hCurrentZS,
    pmDch24hCurrentESs,
    pmDch24hCurrentSESs,
    pmDch24hCurrentBBEs,
    pmDch24hCurrentUASs    
    }
    
    STATUS current
    DESCRIPTION
        "The PM Channel Conformance Group."
    ::= { pmConformanceGroups 3 }

-- -----------------------------------------------------------------
-- The End 
-- -----------------------------------------------------------------    
    
END