-- Copyright (C) 2010 by  HUAWEI TECHNOLOGIES. All rights reserved.
-- Description: The MIB module defining objects for the management of a pair of ATM modems 
--              at each end of the ATM line.  
-- Reference:  
-- Version: V3.07
-- ============================================================================
  HUAWEI-ATM-OAM-MIB DEFINITIONS ::= BEGIN

    IMPORTS 
      AtmVpIdentifier, AtmVcIdentifier      
        FROM ATM-TC-MIB     
      huaweiUtility     
        FROM HUAWEI-MIB     
      ifIndex     
        FROM IF-MIB     
      OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE,Integer32
        FROM SNMPv2-SMI     
      DateAndTime, RowStatus      
        FROM SNMPv2-TC;
  
    hwAtmOam MODULE-IDENTITY
      LAST-UPDATED "201011090000Z"
      ORGANIZATION "Huawei Technologies Co.,Ltd."
      CONTACT-INFO 
        "Huawei Industrial Base
         Bantian, Longgang
         Shenzhen 518129
         People's Republic of China
         Website: http://www.huawei.com
         Email: support@huawei.com
        "
      DESCRIPTION 
        "The MIB module defining objects for the management of a pair of ATM modems 
         at each end of the ATM line. 
        "     
        
--  Revision history
      REVISION     "201011090000Z"        
      DESCRIPTION  "V3.07, modified the description of MIB."
      
      REVISION     "201007290000Z"        
      DESCRIPTION  "V3.06, modified the description of MIB."
            
      REVISION     "201002080000Z"        
      DESCRIPTION  "V3.05, added the definition of the trap node."
     
      REVISION     "201001100000Z"        
      DESCRIPTION  "V3.04, added the definition of the trap node."
            
      REVISION     "200812240000Z"        
      DESCRIPTION  "V3.03, changed the hwAtmOamLbNumber value range from 1-10 to 1-65535."
            
      REVISION     "200805310000Z"        
      DESCRIPTION  "V3.02, deleted chinese character."
            
      REVISION     "200304280000Z"
      DESCRIPTION  "V3.00, added file head and modified MODULE-IDENTITY. "
                                                                            
      REVISION "200209260000Z"
      DESCRIPTION
            "V1.00, initial version."
      ::= { huaweiUtility 11 }  
  
    hwAtmOamMibObjects OBJECT IDENTIFIER ::= { hwAtmOam 1 }
    
    hwAtmOamPointTable OBJECT-TYPE
      SYNTAX SEQUENCE OF HwAtmOamPointEntry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
        "Table of OAM point.
         The indexes of this table are ifIndex,hwAtmOamPointVPI and hwAtmOamPointVCI.
        "
      ::= { hwAtmOamMibObjects 1 }
    
    hwAtmOamPointEntry OBJECT-TYPE
      SYNTAX HwAtmOamPointEntry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
        "Table of OAM point.
         The indexes of this entry are ifIndex,hwAtmOamPointVPI and hwAtmOamPointVCI.
        "
      INDEX { ifIndex,hwAtmOamPointVPI, hwAtmOamPointVCI }
      ::= { hwAtmOamPointTable 1 }
    
    HwAtmOamPointEntry ::=
      SEQUENCE { 
        hwAtmOamPointVPI
          AtmVpIdentifier,
        hwAtmOamPointVCI
          AtmVcIdentifier,
        hwAtmOamPointType
          INTEGER,
        hwAtmOamPointAdminStatus
          INTEGER,
        hwAtmOamAlarmType
          INTEGER,
        hwAtmOamCfgFlag
          INTEGER,
        hwAtmOamFmStatus
          INTEGER,
        hwAtmOamFmStatusDateTime
          DateAndTime,
        hwAtmOamPointRowStatus
          RowStatus
       }

    hwAtmOamPointVPI OBJECT-TYPE
      SYNTAX AtmVpIdentifier
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
        "vpi."
      ::= { hwAtmOamPointEntry 1 }
    
    hwAtmOamPointVCI OBJECT-TYPE
      SYNTAX AtmVcIdentifier
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
        "vci. 
        If vci = 0, it means that this is a F4 point"
      ::= { hwAtmOamPointEntry 2 }
    
    hwAtmOamPointType OBJECT-TYPE
      SYNTAX INTEGER
        {
        e2e(1),
        segment(2),
        e2eInter(3),
        segmentInter(4)
        }
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
        "OAM point type. 
         Options: 
         1. e2e(1)              -e-t-e end point
         2. segment(2)          -segment end point
         3. e2eInter(3)         -connection point within two e-t-e points
         4. segmentInter(4)     -connection point within two segment points
        "
      DEFVAL { segment }
      ::= { hwAtmOamPointEntry 3 }
    
    hwAtmOamPointAdminStatus OBJECT-TYPE
      SYNTAX INTEGER
        {
        up(1),
        down(2)
        }
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
        "up(1) means enable; down(2) means disable.
         Options: 
         1. up(1)            -enable
         2. down(2)          -disable
        "
      DEFVAL { up }
      ::= { hwAtmOamPointEntry 4 }
    
    hwAtmOamAlarmType OBJECT-TYPE
      SYNTAX INTEGER
        {
        noAlarm(0),
        receiveAisCell(1),
        receiveRdiCell(2),
        loc(4),
        f4Ais(8),
        portAlarm(16)
        }
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
        "OAM point alarm type.
         Options: 
         1. noAlarm(0)             -no alarm
         2. receiveAisCell(1)      -received AIS cell
         3. receiveRdiCell(2)      -received RDI cell
         4.loc(4)                  -lost of continuity (CC failed)
         5.f4Ais(8)                -F4 layer AIS alarm. only for F5 point
         6.portAlarm(16)           -F1~F3 layer alarm
         All Alarms can happen at same time which displayed as the relate bit.
        "
      ::= { hwAtmOamPointEntry 5 }
    
    hwAtmOamCfgFlag OBJECT-TYPE
      SYNTAX INTEGER
        {
        running(1),
        recovering(2)
        }
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
        "OAM point configure recovering flag.
         Options: 
         1.running(1)      -OAM point in running stage
         2.recovering(2)   -OAM point in recovering stage
        "
      ::= { hwAtmOamPointEntry 6 }
    
    hwAtmOamFmStatus OBJECT-TYPE
      SYNTAX INTEGER
        {
        normal(1),
        ais(2),
        rdi(3)
        }
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
        "OAM point FM status.
         Options: 
         1. normal(1)           -FM status is normal
         2. ais(2)              -FM status is ais   
         3. rdi(3)              -FM status is rdi 
         "
      ::= { hwAtmOamPointEntry 7 }
    
    hwAtmOamFmStatusDateTime OBJECT-TYPE
      SYNTAX DateAndTime
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
        "The time when the OAM point entered this FM status."
      ::= { hwAtmOamPointEntry 8 }
    
    hwAtmOamPointRowStatus OBJECT-TYPE
      SYNTAX RowStatus
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
        "OAM point table row status."
      ::= { hwAtmOamPointEntry 9 }
    
    hwAtmOamCcTable OBJECT-TYPE
      SYNTAX SEQUENCE OF HwAtmOamCcEntry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
        "Table of CC end point.
         Refer to the definition of the OAM point table.
         The indexes of this table are ifIndex,hwAtmOamCcVPI and hwAtmOamCcVCI.
        "
      ::= { hwAtmOamMibObjects 2 }
    
    hwAtmOamCcEntry OBJECT-TYPE
      SYNTAX HwAtmOamCcEntry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
        "Table of CC end point.
         Refer to the definition of the OAM point table.
         The indexes of this entry are ifIndex,hwAtmOamCcVPI and hwAtmOamCcVCI.
        "
      INDEX { ifIndex,hwAtmOamCcVPI, hwAtmOamCcVCI }
      ::= { hwAtmOamCcTable 1 }
    
    HwAtmOamCcEntry ::=
      SEQUENCE { 
        hwAtmOamCcVPI
          AtmVpIdentifier,
        hwAtmOamCcVCI
          AtmVcIdentifier,
        hwAtmOamCcDirection
          INTEGER,
        hwAtmOamConfType
          INTEGER,
        hwAtmOamCcAdminStatus
          INTEGER,
        hwAtmOamCcRowStatus
          RowStatus
       }

    hwAtmOamCcVPI OBJECT-TYPE
      SYNTAX AtmVpIdentifier
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
        "vpi."
      ::= { hwAtmOamCcEntry 1 }
    
    hwAtmOamCcVCI OBJECT-TYPE
      SYNTAX AtmVcIdentifier
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
        "vci.  
        If vci = 0, it means that this is a F4 point"
      ::= { hwAtmOamCcEntry 2 }
    
    hwAtmOamCcDirection OBJECT-TYPE
      SYNTAX INTEGER
        {
        sink(1),
        source(2),
        both(3)
        }
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
        "OAM CC direction.
         Options: 
         1. sink(1)           -OAM CC direction is sink
         2. source(2)         -OAM CC direction is source
         3. both(3)           -OAM CC direction is both
        "
      DEFVAL { both }
      ::= { hwAtmOamCcEntry 3 }
    
    hwAtmOamConfType OBJECT-TYPE
      SYNTAX INTEGER
        {
        autoConfig(1),
        manualConfig(2)
        }
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
        "OAM CC configure type,only valid for up or down operating.
         Options: 
         1. autoConfig(1)    -active/deactive CC by A/D protocol
         2. manualConfig(2)  -active/deactive CC by TMN entirely. see I.610
        "
      DEFVAL { manualConfig }
      ::= { hwAtmOamCcEntry 4 }
    
    hwAtmOamCcAdminStatus OBJECT-TYPE
      SYNTAX INTEGER
        {
        up(1),
        down(2)
        }
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
        "up(1) means enable; down(2) means disable.
         Options: 
         1. up(1)           -enable
         2. down(2)         -disable
        "
      DEFVAL { up }
      ::= { hwAtmOamCcEntry 5 }
    
    hwAtmOamCcRowStatus OBJECT-TYPE
      SYNTAX RowStatus
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
        "OAM CC end point table row status."
      ::= { hwAtmOamCcEntry 6 }
    
    hwAtmOamLbTable OBJECT-TYPE
      SYNTAX SEQUENCE OF HwAtmOamLbEntry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
        "Table of ATM OAM loopback, it is used for setting flow loopback.
         The indexes of this table are ifIndex,hwAtmOamLbVPI and hwAtmOamLbVCI.
         "
      ::= { hwAtmOamMibObjects 3 }
    
    hwAtmOamLbEntry OBJECT-TYPE
      SYNTAX HwAtmOamLbEntry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
        "Table of ATM OAM loopback, it is used for setting flow loopback.
         The indexes of this entry are ifIndex,hwAtmOamLbVPI and hwAtmOamLbVCI.
         "
      INDEX { ifIndex,hwAtmOamLbVPI, hwAtmOamLbVCI }
      ::= { hwAtmOamLbTable 1 }
    
    HwAtmOamLbEntry ::=
      SEQUENCE { 
        hwAtmOamLbVPI
          AtmVpIdentifier,
        hwAtmOamLbVCI
          AtmVcIdentifier,
        hwAtmOamLbType
          INTEGER,
        hwAtmOamLbPointLLID
          OCTET STRING,
        hwAtmOamLbNumber
          Integer32,
        hwAtmOamLbInterval
          Integer32
       }

    hwAtmOamLbVPI OBJECT-TYPE
      SYNTAX AtmVpIdentifier
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
        "Vpi of the OAM loopback flow."
      ::= { hwAtmOamLbEntry 1 }
    
    hwAtmOamLbVCI OBJECT-TYPE
      SYNTAX AtmVcIdentifier
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
        "Vci of the OAM loopback flow. 
         If vci = 0, means that this is a F4 point.
         "
      ::= { hwAtmOamLbEntry 2 }
    
    hwAtmOamLbType OBJECT-TYPE
      SYNTAX INTEGER
        {
        e2e(1),
        segment(2),
        llid(3),
        noloopback(4)
        }
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
        "OAM loopback type.
         Options: 
         1. e2e(1)         -end to end loopback
         2. segment(2)     -segment loopback
         3. llid(3)        -specified llid loopback
         4. noloopback(4)  -stopping loopback 
         "
      DEFVAL { segment }
      ::= { hwAtmOamLbEntry 3 }
    
    hwAtmOamLbPointLLID OBJECT-TYPE
      SYNTAX OCTET STRING (SIZE (0..16))
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
        "Specify loopback destination LLID. 
         It is valid to be set llid(3) for hwAtmOamLbType only. 
        "
      ::= { hwAtmOamLbEntry 4 }
    
    hwAtmOamLbNumber OBJECT-TYPE
      SYNTAX Integer32 (1..65535)
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
        "Specify the number of the cells loopbacked.
        "
      ::= { hwAtmOamLbEntry 5 }
    
    hwAtmOamLbInterval OBJECT-TYPE
      SYNTAX Integer32 (1..5)
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
        "Specify the interval between two insert operation. "
      ::= { hwAtmOamLbEntry 6 }
    
    hwAtmOamLlidTable OBJECT-TYPE
      SYNTAX SEQUENCE OF HwAtmOamLlidEntry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
        "Table of OAM LLID.
         The index of this table is ifIndex.
        "
      ::= { hwAtmOamMibObjects 4 }
    
    hwAtmOamLlidEntry OBJECT-TYPE
      SYNTAX HwAtmOamLlidEntry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
        "Table of OAM LLID.
         The index of this entry is ifIndex.
        "
      INDEX { ifIndex }
      ::= { hwAtmOamLlidTable 1 }
    
    HwAtmOamLlidEntry ::=
      SEQUENCE { 
        hwAtmOamLlidPointLLID
          OCTET STRING
       }

    hwAtmOamLlidPointLLID OBJECT-TYPE
      SYNTAX OCTET STRING (SIZE (0..16))
      MAX-ACCESS read-write
      STATUS current
      DESCRIPTION
        "local interface LLID. "
      ::= { hwAtmOamLlidEntry 1 }
    
    hwAtmOamInsertTable OBJECT-TYPE
      SYNTAX SEQUENCE OF HwAtmOamInsertEntry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
        "Table of OAM Insert.
         This table only support 'set' operation.
         The indexes of this table are ifIndex,hwAtmOamInsertVPI and hwAtmOamInsertVCI.
        "
      ::= { hwAtmOamMibObjects 5 }
    
    hwAtmOamInsertEntry OBJECT-TYPE
      SYNTAX HwAtmOamInsertEntry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
        "Table of OAM Insert.
         This table only support 'set' operation.
         The indexes of this entry are ifIndex,hwAtmOamInsertVPI and hwAtmOamInsertVCI.
        "
      INDEX { ifIndex,hwAtmOamInsertVPI, hwAtmOamInsertVCI }
      ::= { hwAtmOamInsertTable 1 }
    
    HwAtmOamInsertEntry ::=
      SEQUENCE { 
        hwAtmOamInsertVPI
          AtmVpIdentifier,
        hwAtmOamInsertVCI
          AtmVcIdentifier,
        hwAtmOamInsertOperation
          INTEGER,
        hwAtmOamInsertSegment
          INTEGER,
        hwAtmOamInsertCellType
          INTEGER
       }

    hwAtmOamInsertVPI OBJECT-TYPE
      SYNTAX AtmVpIdentifier
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
        "vpi."
      ::= { hwAtmOamInsertEntry 1 }
    
    hwAtmOamInsertVCI OBJECT-TYPE
      SYNTAX AtmVcIdentifier
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
        "vci. 
        if vci = 0, means that this is a F4 point."
      ::= { hwAtmOamInsertEntry 2 }
    
    hwAtmOamInsertOperation OBJECT-TYPE
      SYNTAX INTEGER
        {
        start(1),
        stop(2)
        }
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
        "specify the operation(begin or stop) of the insertion.
         Options: 
         1. start(1)           -the operation of the insertion is begin 
         2. stop(2)            -the operation of the insertion is stop
        "
      ::= { hwAtmOamInsertEntry 3 }
    
    hwAtmOamInsertSegment OBJECT-TYPE
      SYNTAX INTEGER
        {
        segment(1),
        end(2)
        }
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
        "specify the segment type.
         Options: 
         1. segment(1)           -specify the segment type is segment 
         2. end(2)               -specify the segment type is end
        "
      ::= { hwAtmOamInsertEntry 4 }
    
    hwAtmOamInsertCellType OBJECT-TYPE
      SYNTAX INTEGER
        {
        ais(1),
        rdi(2),
        cc(3)
        }
      MAX-ACCESS read-create
      STATUS current
      DESCRIPTION
        "specify the type of the inserted cell. 
         Options: 
         1. ais(1)           -specify the type of the inserted cell is ais 
         2. rdi(2)           -specify the type of the inserted cell is rdi
         3. cc(3)            -specify the type of the inserted cell is cc
        "
      ::= { hwAtmOamInsertEntry 5 }
    
    hwAtmOamTraps OBJECT IDENTIFIER ::= { hwAtmOam 2 }
    
    hwAtmOamTrapVarBindOids OBJECT IDENTIFIER ::= { hwAtmOamTraps 1 }
    
    hwAtmOamGeneralVarBindOids OBJECT IDENTIFIER ::= { hwAtmOamTrapVarBindOids 1 }
    
    hwAtmOamVarBindLoopbackResult OBJECT-TYPE
      SYNTAX INTEGER
        {
        success(1),
        timeout(2)
        }
      MAX-ACCESS accessible-for-notify
      STATUS current
      DESCRIPTION
        "Loopback result.
         Options: 
         1. success(1)          -loopback success
         2. timeout(2)          -not received loopback cell for 5 seconds after sent
       "
      ::= { hwAtmOamGeneralVarBindOids 1 }
    
    hwAtmOamVarBindOidsReason OBJECT IDENTIFIER ::= { hwAtmOamTrapVarBindOids 2 }
    
    hwAtmOamAisReason OBJECT-TYPE
      SYNTAX INTEGER
        {
        connDelete(1),
        boardFail(2)
        }
      MAX-ACCESS accessible-for-notify
      STATUS current
      DESCRIPTION
        "OAM operation terminate reason.
         Options: 
         1. connDelete(1)            -ATM connection be deleted 
         2. boardFail(2)             -Board fail
        "
      ::= { hwAtmOamVarBindOidsReason 1 }
    
    hwAtmOamOperTerminateReason OBJECT-TYPE
      SYNTAX INTEGER
        {
        connDelete(1),
        boardFail(2)
        }
      MAX-ACCESS accessible-for-notify
      STATUS current
      DESCRIPTION
        "OAM operation terminate reason:
         Options: 
         1. connDelete(1)            -ATM connection be deleted 
         2. boardFail(2)             -Board fail
        "
      ::= { hwAtmOamVarBindOidsReason 2 }
    
    hwAtmOamAlarmTraps OBJECT IDENTIFIER ::= { hwAtmOamTraps 2 }
    
    hwAtmOamAlarmTrapsOids OBJECT IDENTIFIER ::= { hwAtmOamAlarmTraps 0 }
    
    hwAtmOamAlarmAis NOTIFICATION-TYPE
      OBJECTS { ifIndex, hwAtmOamPointVPI, hwAtmOamPointVCI }
      STATUS current
      DESCRIPTION
        "This trap will send when there is some defect in the upstream.
        alarm description:AIS alarm.
        explain: AIS cell received from upstream.
        resolving method:Check if there is some defect in the upstream.
        "
      ::= { hwAtmOamAlarmTrapsOids 1 }
    
    hwAtmOamAlarmAisRestore NOTIFICATION-TYPE
      OBJECTS { ifIndex, hwAtmOamPointVPI, hwAtmOamPointVCI }
      STATUS current
      DESCRIPTION
        "This trap will send when there is no AIS cell received from upstream within a time interval of 2.5 seconds, with a margin of 0.5 seconds.
        alarm description: AIS alarm restore.
        explain: There is no AIS cell received from upstream within a time interval of 2.5 seconds, with a margin of 0.5 seconds.
        resolving method:NA.
        "
      ::= { hwAtmOamAlarmTrapsOids 2 }
    
    hwAtmOamAlarmRdi NOTIFICATION-TYPE
      OBJECTS { ifIndex, hwAtmOamPointVPI, hwAtmOamPointVCI }
      STATUS current
      DESCRIPTION
        "This trap will send when there is some defect in the downstream.
        alarm description:RDI alarm.
        explain: RDI cell received from downstream.
        resolving method:Check if there is some defect in the downstream.
        "
      ::= { hwAtmOamAlarmTrapsOids 3 }
    
    hwAtmOamAlarmRdiRestore NOTIFICATION-TYPE
      OBJECTS { ifIndex, hwAtmOamPointVPI, hwAtmOamPointVCI }
      STATUS current
      DESCRIPTION
        "This trap will send when there is no RDI cell received from downstream within a time interval of 2.5 seconds, with a margin of 0.5 seconds.
        alarm description:RDI alarm restore
        explain: There is no RDI cell received from downstream within a time interval of 2.5 seconds, with a margin of 0.5 seconds.
        resolving method:NA.
        "
      ::= { hwAtmOamAlarmTrapsOids 4 }
    
    hwAtmOamAlarmLoc NOTIFICATION-TYPE
      OBJECTS { ifIndex, hwAtmOamPointVPI, hwAtmOamPointVCI }
      STATUS current
      DESCRIPTION
        "This trap will send when CC sink can not receive CC cells from source within a time interval of 3.5 seconds,with a margin of 0.5 seconds;Or physical fault is detected.
        alarm description:LOC alarm.
        explain: CC sink can not receive CC cells from source within a time interval of 3.5 seconds,with a margin of 0.5 seconds;Or physical fault is detected.
        resolving method:Check if there is some physical fault.check if there is some defect between CC source and CC sink.check if CC source is configured correctly.
        "
      ::= { hwAtmOamAlarmTrapsOids 5 }
    
    hwAtmOamAlarmLocRestore NOTIFICATION-TYPE
      OBJECTS { ifIndex, hwAtmOamPointVPI, hwAtmOamPointVCI }
      STATUS current
      DESCRIPTION
        "This trap will send when CC cells can be received from CC source.Or physical fault is restored.
        alarm description:LOC alarm restore.
        explain: CC cells can be received from CC source.Or physical fault is restored.
        resolving method:NA.
        "
      ::= { hwAtmOamAlarmTrapsOids 6 }
    
    hwAtmOamAlarmLbTerminate NOTIFICATION-TYPE
      OBJECTS { ifIndex, hwAtmOamPointVPI, hwAtmOamPointVCI, hwAtmOamOperTerminateReason }
      STATUS current
      DESCRIPTION
        "This trap will send when the corresponding connection is deleted or there is some fault in the corresponding board.
        alarm description:LB abort alarm.
        explain: 1.The corresponding connection is deleted.
                 2.There is some fault in the corresponding board. 
        resolving method:Until the board changes normal, and renew configuring if necessary.

        "
      ::= { hwAtmOamAlarmTrapsOids 7 }
    
    hwAtmOamAlarmInsTerminate NOTIFICATION-TYPE
      OBJECTS { ifIndex, hwAtmOamPointVPI, hwAtmOamPointVCI, hwAtmOamOperTerminateReason }
      STATUS current
      DESCRIPTION
        "This trap will send when the corresponding connection is deleted or there is some fault in the corresponding board.
        alarm description:Insertion abort alarm.
        explain: 1.The corresponding connection is deleted.
                 2.There is some fault in the corresponding board. 
        resolving method:Until the board changes normal, and renew configuring if necessary.
        "
      ::= { hwAtmOamAlarmTrapsOids 8 }
    
    hwAtmOamGeneralTraps OBJECT IDENTIFIER ::= { hwAtmOamTraps 3 }
    
    hwAtmOamGeneralTrapsOids OBJECT IDENTIFIER ::= { hwAtmOamGeneralTraps 0 }
    
    hwAtmOamTrapLoopbackReport NOTIFICATION-TYPE
      OBJECTS { hwAtmOamLbPointLLID, hwAtmOamVarBindLoopbackResult, hwAtmOamLbVPI, hwAtmOamLbVCI, ifIndex
         }
      STATUS current
      DESCRIPTION
        "This trap will send when the loopback result of LB cell return.
        General trap description:
        Used to send loopback result of LB cell, success(1) or timeout(2).
        "
      ::= { hwAtmOamGeneralTrapsOids 1 }
      
    hwAtmOamPingLoopTestTrap NOTIFICATION-TYPE
      OBJECTS {
              ifIndex,
              hwAtmOamLbVPI ,
              hwAtmOamLbVCI,
              hwAtmOamLbCurrentNumber,
              hwAtmOamLbCurrentResult        
          } 
      STATUS current
      DESCRIPTION 
             "The trap whill send when the ATM ping loop test finished."
      ::= { hwAtmOamGeneralTrapsOids  2 }
    
    
    hwAtmOamTrapsVbOids OBJECT IDENTIFIER ::= { hwAtmOam 3 }
    
    hwAtmOamLbCurrentNumber OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS accessible-for-notify
      STATUS current
      DESCRIPTION
        "The current atmping number."
      ::= { hwAtmOamTrapsVbOids 1 }
    
    hwAtmOamLbCurrentResult OBJECT-TYPE
      SYNTAX Integer32 
      MAX-ACCESS accessible-for-notify
      STATUS current
      DESCRIPTION
        "The current atmping result.
         Options:
         1. successful(0)   -the current atmping successful
         2. timeout(1)      -the current atmping timeout
         3. boardfailed(2)  -the board failed
        "
      ::= { hwAtmOamTrapsVbOids 2 }     
    
  END