--  (C) COPYRIGHT HEWLETT-PACKARD COMPANY 2015.
--
--  LaserJet 477 Printer Model Specific MIB.
--
--  Generated on Sep. 16, 2015.
--
--  Company names and product names mentioned herein may be 
--  trademarks, and/or registered trademarks of their respective
--  companies.
--
--  For internal and external use.
--
--  This MIB describes all the printer model specific
--  objects supported by the LaserJet 477 printer
--  when networked connected.
--
--  The following MIBs also contain objects supported
--  by a LaserJet 477 printer:
--
--  IEEE 802.11 MIB
--  IEEE 802.1X MIB
--  rfc 2790 Host Resources MIB
--  rfc 3411 SNMP Framework MIB
--  rfc 3412 SNMP MPD MIB
--  rfc 3418 SNMP MIB
--  rfc 3805 Printer MIB
--  rfc 4022 TCP MIB
--  rfc 4293 IP MIB
--  rfc 4113 UDP MIB
--  PWG 5107.1-2005 Printer Port Monitor MIB
--
--  This MIB complies with the following RFCs:
--
--  rfc 1157 Simple Network Management Protocol
--  rfc 2578 Structure of Management Information Version 2
--
--  Notes:
--
--  1) Objects containing a string which are defined in this MIB use the
--     first two bytes to hold the symbol set used to encode the string.
--     The Roman-8 symbol set has a hex encoding of 0x0115.  Other 
--     symbol sets are listed in the PCL 5 Comparison Guide in table
--     C-1 Symbol Set Values.
--
--  2) Some of the objects included are only supported if an accessory 
--     is installed.  These accessories include:
--       MIO based accessories
--       SIMM based accessories
--       Paper handling accessories

LJ477-MIB DEFINITIONS ::= BEGIN

IMPORTS
	OBJECT-TYPE
		FROM RFC-1212

	DisplayString
		FROM SNMPv2-TC;

hpPrintServer OBJECT IDENTIFIER ::= { iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) 11}
dm OBJECT IDENTIFIER ::= { hpPrintServer nm(2) hpsystem(3) net-peripheral(9) netdm(4) 2}

device                                 OBJECT IDENTIFIER ::=  { dm 1 } 
system                                 OBJECT IDENTIFIER ::=  { device 1 } 
settings-system                        OBJECT IDENTIFIER ::=  { system 1 } 
destination-subsystem                  OBJECT IDENTIFIER ::=  { device 4 } 
print-engine                           OBJECT IDENTIFIER ::=  { destination-subsystem 1 } 
settings-prt-eng                       OBJECT IDENTIFIER ::=  { print-engine 1 } 
marking-agent-density                  OBJECT IDENTIFIER ::=  { settings-prt-eng 9 } 
status-prt-eng                         OBJECT IDENTIFIER ::=  { print-engine 2 } 
marking-agent                          OBJECT IDENTIFIER ::=  { print-engine 5 } 
settings-marking-agent                 OBJECT IDENTIFIER ::=  { marking-agent 1 } 
source-subsystem                       OBJECT IDENTIFIER ::=  { device 2 } 
scanner                                OBJECT IDENTIFIER ::=  { source-subsystem 2 } 
status-scanner                         OBJECT IDENTIFIER ::=  { scanner 2 } 
copier                                 OBJECT IDENTIFIER ::=  { device 5 } 
settings-copier                        OBJECT IDENTIFIER ::=  { copier 1 } 
status-system                          OBJECT IDENTIFIER ::=  { system 2 } 
id                                     OBJECT IDENTIFIER ::=  { system 3 } 
job                                    OBJECT IDENTIFIER ::=  { system 6 } 
fax-job-control                        OBJECT IDENTIFIER ::=  { job 3 } 
settings-fax-job                       OBJECT IDENTIFIER ::=  { fax-job-control 1 } 
status-fax-job                         OBJECT IDENTIFIER ::=  { fax-job-control 2 } 
faxjob                                 OBJECT IDENTIFIER ::=  { fax-job-control 3 } 
faxjob-rx-status                       OBJECT IDENTIFIER ::=  { faxjob 1 } 
faxjob-tx-status                       OBJECT IDENTIFIER ::=  { faxjob 3 } 
faxjob-tx-error                        OBJECT IDENTIFIER ::=  { faxjob 4 } 
faxjob-tx-current-page                 OBJECT IDENTIFIER ::=  { faxjob 5 } 
faxjob-rx-current-page                 OBJECT IDENTIFIER ::=  { faxjob 6 } 
faxjob-rx-duration                     OBJECT IDENTIFIER ::=  { faxjob 7 } 
faxjob-tx-duration                     OBJECT IDENTIFIER ::=  { faxjob 8 } 
fax-activity-log                       OBJECT IDENTIFIER ::=  { job 4 } 
settings-faxlog                        OBJECT IDENTIFIER ::=  { fax-activity-log 1 } 
phone                                  OBJECT IDENTIFIER ::=  { system 9 } 
dial                                   OBJECT IDENTIFIER ::=  { phone 1 } 
dial-all-lines                         OBJECT IDENTIFIER ::=  { dial 1 } 
answer                                 OBJECT IDENTIFIER ::=  { phone 2 } 
answer-all-lines                       OBJECT IDENTIFIER ::=  { answer 1 } 
fax-receive                            OBJECT IDENTIFIER ::=  { source-subsystem 3 } 
settings-fax-receive                   OBJECT IDENTIFIER ::=  { fax-receive 1 } 
status-fax-receive                     OBJECT IDENTIFIER ::=  { fax-receive 2 } 
processing-subsystem                   OBJECT IDENTIFIER ::=  { device 3 } 
fax-proc-sub                           OBJECT IDENTIFIER ::=  { processing-subsystem 7 } 
settings-fax-proc-sub                  OBJECT IDENTIFIER ::=  { fax-proc-sub 1 } 
status-fax-proc-sub                    OBJECT IDENTIFIER ::=  { fax-proc-sub 2 } 
fax-forwarding                         OBJECT IDENTIFIER ::=  { fax-proc-sub 3 } 
fax-send                               OBJECT IDENTIFIER ::=  { destination-subsystem 2 } 
settings-fax-send                      OBJECT IDENTIFIER ::=  { fax-send 1 } 
status-fax-send                        OBJECT IDENTIFIER ::=  { fax-send 2 } 
transmit-fax                           OBJECT IDENTIFIER ::=  { fax-send 5 } 
hrm                                    OBJECT IDENTIFIER ::=  { dm 3 } 
hrStorage                              OBJECT IDENTIFIER ::=  { hrm 2 } 
hrStorageTable                         OBJECT IDENTIFIER ::=  { hrStorage 3 } 
hrStorageEntry                         OBJECT IDENTIFIER ::=  { hrStorageTable 1 } 
hrDevice                               OBJECT IDENTIFIER ::=  { hrm 3 } 
hrDeviceTable                          OBJECT IDENTIFIER ::=  { hrDevice 2 } 
hrDeviceEntry                          OBJECT IDENTIFIER ::=  { hrDeviceTable 1 } 
hrPrinterTable                         OBJECT IDENTIFIER ::=  { hrDevice 5 } 
hrPrinterEntry                         OBJECT IDENTIFIER ::=  { hrPrinterTable 1 } 
iso                                    OBJECT IDENTIFIER ::=  { dm 1 } 
org                                    OBJECT IDENTIFIER ::=  { iso 3 } 
dod                                    OBJECT IDENTIFIER ::=  { org 6 } 
internet                               OBJECT IDENTIFIER ::=  { dod 1 } 
private                                OBJECT IDENTIFIER ::=  { internet 4 } 
enterprises                            OBJECT IDENTIFIER ::=  { private 1 } 
nm                                     OBJECT IDENTIFIER ::=  { hpPrintServer 2 } 
interface                              OBJECT IDENTIFIER ::=  { nm 4 } 
npCard                                 OBJECT IDENTIFIER ::=  { interface 3 } 
npCRCTable                             OBJECT IDENTIFIER ::=  { npCard 15 } 
npCRCEntry                             OBJECT IDENTIFIER ::=  { npCRCTable 1 } 
inetTrap                               OBJECT IDENTIFIER ::=  { npCard 22 } 
inetTrapDestination                    OBJECT IDENTIFIER ::=  { inetTrap 1 } 
inetTrapDestinationTable               OBJECT IDENTIFIER ::=  { inetTrapDestination 2 } 
inetTrapDestinationEntry               OBJECT IDENTIFIER ::=  { inetTrapDestinationTable 1 } 
trap                                   OBJECT IDENTIFIER ::=  { nm 13 } 
trapDest                               OBJECT IDENTIFIER ::=  { trap 1 } 
trapFQDNTable                          OBJECT IDENTIFIER ::=  { trapDest 7 } 
trapFQDNEntry                          OBJECT IDENTIFIER ::=  { trapFQDNTable 1 } 
snmpAccess                             OBJECT IDENTIFIER ::=  { nm 15 } 
community                              OBJECT IDENTIFIER ::=  { snmpAccess 1 } 
npSys                                  OBJECT IDENTIFIER ::=  { npCard 1 } 
npConns                                OBJECT IDENTIFIER ::=  { npCard 4 } 
npCfg                                  OBJECT IDENTIFIER ::=  { npCard 5 } 
npCfgAccessListTable                   OBJECT IDENTIFIER ::=  { npCfg 9 } 
npCfgAccessListEntry                   OBJECT IDENTIFIER ::=  { npCfgAccessListTable 1 } 
npTcp                                  OBJECT IDENTIFIER ::=  { npCard 6 } 
npCtl                                  OBJECT IDENTIFIER ::=  { npCard 7 } 
npPort                                 OBJECT IDENTIFIER ::=  { npCard 13 } 
npDhcp                                 OBJECT IDENTIFIER ::=  { npCard 16 } 
npWeb                                  OBJECT IDENTIFIER ::=  { npCard 18 } 
npSecurity                             OBJECT IDENTIFIER ::=  { npCard 20 } 
npSecurityDot11EncryptedWEPKeyTable    OBJECT IDENTIFIER ::=  { npSecurity 7 } 
npSecurityDot11EncryptedWEPKeyEntry    OBJECT IDENTIFIER ::=  { npSecurityDot11EncryptedWEPKeyTable 1 } 
npSecurityDot11SSIDTable               OBJECT IDENTIFIER ::=  { npSecurity 9 } 
npSecurityDot11SSIDEntry               OBJECT IDENTIFIER ::=  { npSecurityDot11SSIDTable 1 } 
system                                 OBJECT IDENTIFIER ::=  { nm 3 } 
netPeripheral                          OBJECT IDENTIFIER ::=  { system 9 } 
netPrinter                             OBJECT IDENTIFIER ::=  { netPeripheral 1 } 
generalDeviceStatus                    OBJECT IDENTIFIER ::=  { netPrinter 1 } 
netPML                                 OBJECT IDENTIFIER ::=  { netPeripheral 4 } 
netPMLtrap                             OBJECT IDENTIFIER ::=  { netPML 1 } 
npNpi                                  OBJECT IDENTIFIER ::=  { npCard 8 } 
npNpiPeripheralAttributeEntry          OBJECT IDENTIFIER ::=  { npNpi 3 } 
npNpiCardAttributeEntry                OBJECT IDENTIFIER ::=  { npNpi 4 } 
gdStatusEntry                          OBJECT IDENTIFIER ::=  { generalDeviceStatus 2 } 
photo-job                              OBJECT IDENTIFIER ::=  { job 8 } 
device-configure                       OBJECT IDENTIFIER ::=  { settings-system 32 } 
display                                OBJECT IDENTIFIER ::=  { status-system 20 } 
display-status                         OBJECT IDENTIFIER ::=  { display 1 } 
interface                              OBJECT IDENTIFIER ::=  { system 4 } 
simm                                   OBJECT IDENTIFIER ::=  { interface 1 } 
simm1                                  OBJECT IDENTIFIER ::=  { simm 1 } 
test                                   OBJECT IDENTIFIER ::=  { system 5 } 
settings-job                           OBJECT IDENTIFIER ::=  { job 1 } 
active-print-jobs                      OBJECT IDENTIFIER ::=  { job 2 } 
job-being-parsed                       OBJECT IDENTIFIER ::=  { active-print-jobs 1 } 
job-info                               OBJECT IDENTIFIER ::=  { job 5 } 
errorlog                               OBJECT IDENTIFIER ::=  { system 11 } 
error1                                 OBJECT IDENTIFIER ::=  { errorlog 1 } 
error2                                 OBJECT IDENTIFIER ::=  { errorlog 2 } 
error3                                 OBJECT IDENTIFIER ::=  { errorlog 3 } 
error4                                 OBJECT IDENTIFIER ::=  { errorlog 4 } 
error5                                 OBJECT IDENTIFIER ::=  { errorlog 5 } 
error6                                 OBJECT IDENTIFIER ::=  { errorlog 6 } 
error7                                 OBJECT IDENTIFIER ::=  { errorlog 7 } 
error8                                 OBJECT IDENTIFIER ::=  { errorlog 8 } 
error9                                 OBJECT IDENTIFIER ::=  { errorlog 9 } 
error10                                OBJECT IDENTIFIER ::=  { errorlog 10 } 
firmware-download                      OBJECT IDENTIFIER ::=  { system 18 } 
io                                     OBJECT IDENTIFIER ::=  { source-subsystem 1 } 
settings-io                            OBJECT IDENTIFIER ::=  { io 1 } 
pdl                                    OBJECT IDENTIFIER ::=  { processing-subsystem 3 } 
settings-pdl                           OBJECT IDENTIFIER ::=  { pdl 1 } 
pdl-pcl                                OBJECT IDENTIFIER ::=  { pdl 3 } 
pdl-postscript                         OBJECT IDENTIFIER ::=  { pdl 4 } 
pjl                                    OBJECT IDENTIFIER ::=  { processing-subsystem 5 } 
intray                                 OBJECT IDENTIFIER ::=  { print-engine 3 } 
settings-intray                        OBJECT IDENTIFIER ::=  { intray 1 } 
intrays                                OBJECT IDENTIFIER ::=  { intray 3 } 
intray1                                OBJECT IDENTIFIER ::=  { intrays 1 } 
intray2                                OBJECT IDENTIFIER ::=  { intrays 2 } 
intray3                                OBJECT IDENTIFIER ::=  { intrays 3 } 
imaging                                OBJECT IDENTIFIER ::=  { print-engine 6 } 
print-media                            OBJECT IDENTIFIER ::=  { print-engine 8 } 
settings-print-media                   OBJECT IDENTIFIER ::=  { print-media 1 } 
media-info                             OBJECT IDENTIFIER ::=  { print-media 3 } 
media1                                 OBJECT IDENTIFIER ::=  { media-info 1 } 
media2                                 OBJECT IDENTIFIER ::=  { media-info 2 } 
media3                                 OBJECT IDENTIFIER ::=  { media-info 3 } 
media4                                 OBJECT IDENTIFIER ::=  { media-info 4 } 
media5                                 OBJECT IDENTIFIER ::=  { media-info 5 } 
media6                                 OBJECT IDENTIFIER ::=  { media-info 6 } 
media7                                 OBJECT IDENTIFIER ::=  { media-info 7 } 
media8                                 OBJECT IDENTIFIER ::=  { media-info 8 } 
media9                                 OBJECT IDENTIFIER ::=  { media-info 9 } 
media10                                OBJECT IDENTIFIER ::=  { media-info 10 } 
media11                                OBJECT IDENTIFIER ::=  { media-info 11 } 
media12                                OBJECT IDENTIFIER ::=  { media-info 12 } 
media13                                OBJECT IDENTIFIER ::=  { media-info 13 } 
media14                                OBJECT IDENTIFIER ::=  { media-info 14 } 
media15                                OBJECT IDENTIFIER ::=  { media-info 15 } 
media16                                OBJECT IDENTIFIER ::=  { media-info 16 } 
media17                                OBJECT IDENTIFIER ::=  { media-info 17 } 
media18                                OBJECT IDENTIFIER ::=  { media-info 18 } 
media19                                OBJECT IDENTIFIER ::=  { media-info 19 } 
media20                                OBJECT IDENTIFIER ::=  { media-info 20 } 
media21                                OBJECT IDENTIFIER ::=  { media-info 21 } 
media22                                OBJECT IDENTIFIER ::=  { media-info 22 } 
media23                                OBJECT IDENTIFIER ::=  { media-info 23 } 
media24                                OBJECT IDENTIFIER ::=  { media-info 24 } 
media-modes                            OBJECT IDENTIFIER ::=  { print-media 4 } 
consumables                            OBJECT IDENTIFIER ::=  { print-engine 10 } 
consumables-1                          OBJECT IDENTIFIER ::=  { consumables 1 } 
consumable-status                      OBJECT IDENTIFIER ::=  { consumables-1 1 } 
consumables-status                     OBJECT IDENTIFIER ::=  { consumables 5 } 
consumables-life                       OBJECT IDENTIFIER ::=  { consumables-status 1 } 
consumables-test                       OBJECT IDENTIFIER ::=  { consumables 6 } 
settings-scanner                       OBJECT IDENTIFIER ::=  { scanner 1 } 
scan-calibration                       OBJECT IDENTIFIER ::=  { settings-scanner 32 } 
printmib                               OBJECT IDENTIFIER ::=  { dm 2 } 
prtGeneral                             OBJECT IDENTIFIER ::=  { printmib 5 } 
prtGeneralTable                        OBJECT IDENTIFIER ::=  { prtGeneral 1 } 
prtGeneralEntry                        OBJECT IDENTIFIER ::=  { prtGeneralTable 1 } 
prtCover                               OBJECT IDENTIFIER ::=  { printmib 6 } 
prtCoverTable                          OBJECT IDENTIFIER ::=  { prtCover 1 } 
prtCoverEntry                          OBJECT IDENTIFIER ::=  { prtCoverTable 1 } 
prtLocalization                        OBJECT IDENTIFIER ::=  { printmib 7 } 
prtLocalizationTable                   OBJECT IDENTIFIER ::=  { prtLocalization 1 } 
prtLocalizationEntry                   OBJECT IDENTIFIER ::=  { prtLocalizationTable 1 } 
prtStorageRefTable                     OBJECT IDENTIFIER ::=  { prtGeneral 2 } 
prtStorageRefEntry                     OBJECT IDENTIFIER ::=  { prtStorageRefTable 1 } 
prtDeviceRefTable                      OBJECT IDENTIFIER ::=  { prtGeneral 3 } 
prtDeviceRefEntry                      OBJECT IDENTIFIER ::=  { prtDeviceRefTable 1 } 
prtInput                               OBJECT IDENTIFIER ::=  { printmib 8 } 
prtInputTable                          OBJECT IDENTIFIER ::=  { prtInput 2 } 
prtInputEntry                          OBJECT IDENTIFIER ::=  { prtInputTable 1 } 
prtOutput                              OBJECT IDENTIFIER ::=  { printmib 9 } 
prtOutputTable                         OBJECT IDENTIFIER ::=  { prtOutput 2 } 
prtOutputEntry                         OBJECT IDENTIFIER ::=  { prtOutputTable 1 } 
prtMarker                              OBJECT IDENTIFIER ::=  { printmib 10 } 
prtMarkerTable                         OBJECT IDENTIFIER ::=  { prtMarker 2 } 
prtMarkerEntry                         OBJECT IDENTIFIER ::=  { prtMarkerTable 1 } 
prtMarkerSupplies                      OBJECT IDENTIFIER ::=  { printmib 11 } 
prtMarkerSuppliesTable                 OBJECT IDENTIFIER ::=  { prtMarkerSupplies 1 } 
prtMarkerSuppliesEntry                 OBJECT IDENTIFIER ::=  { prtMarkerSuppliesTable 1 } 
prtMarkerColorant                      OBJECT IDENTIFIER ::=  { printmib 12 } 
prtMarkerColorantTable                 OBJECT IDENTIFIER ::=  { prtMarkerColorant 1 } 
prtMarkerColorantEntry                 OBJECT IDENTIFIER ::=  { prtMarkerColorantTable 1 } 
prtMediaPath                           OBJECT IDENTIFIER ::=  { printmib 13 } 
prtMediaPathTable                      OBJECT IDENTIFIER ::=  { prtMediaPath 4 } 
prtMediaPathEntry                      OBJECT IDENTIFIER ::=  { prtMediaPathTable 1 } 
prtInterpreter                         OBJECT IDENTIFIER ::=  { printmib 15 } 
prtInterpreterTable                    OBJECT IDENTIFIER ::=  { prtInterpreter 1 } 
prtInterpreterEntry                    OBJECT IDENTIFIER ::=  { prtInterpreterTable 1 } 
prtConsoleDisplayBuffer                OBJECT IDENTIFIER ::=  { printmib 16 } 
prtConsoleDisplayBufferTable           OBJECT IDENTIFIER ::=  { prtConsoleDisplayBuffer 5 } 
prtConsoleDisplayBufferEntry           OBJECT IDENTIFIER ::=  { prtConsoleDisplayBufferTable 1 } 


mono-color-switching-mode OBJECT-TYPE
    SYNTAX      INTEGER {
                          eNeverSwitch(1),
                          eAlwaysSwitch(2),
                          eLookAheadSwitch(3)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "This object allows the user to view/change the color/mono		
                switching mode for a device.
                Additional information:
                This object allows the user to view/change the color/mono		
                switching mode for a device."
::= { settings-system 31 }


calibration-power-on-initiation OBJECT-TYPE
    SYNTAX      INTEGER {
                          eOff(1),
                          eOn(2),
                          eDelayed(3)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "This object determines when a power on calibration occurs. If		
                eOn, then the calibration occurs immediately following boot. If		
                eOff, then it never occurs. If eDelayed, then refer to the		
                CALIBRATION-POWER-ON-DELAY PML object for the delay interval."
::= { settings-prt-eng 20 }


calibration-power-on-delay OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "This is the delay interval for the power on calibration in		
                minutes. This PML object is only used if the		
                CALIBRATION-POWER-ON-INITIATION PML object is set to eDelayed.
                Additional information:
                This is the delay interval for the power on 
                		calibration in minutes. The range in minutes for the product 
                		is 1-60 minutes. "
::= { settings-prt-eng 21 }


calibration-pages-printed-initiation OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The number of pages that will be printed prior to an		
                automatically initiated print calibration. If set to 0, it		
                turns this calibration off.
                Additional information:
                This is the number of pages that will be printed 
                		prior to an automatically initiated print calibration.  
                		If set to 0, it turns this calibration off. The range for
                		the product will be 0-500. On Raptor the default value is
                	        200.  On Kiwi the default value is 150"
::= { settings-prt-eng 22 }


calibration-timer-initiation OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "This is a timer in minutes that will be set in between		
                calibrations. When the timer expires, a calibration will		
                automatically be initiated. If set to 0, it turns this		
                calibration off.
                Additional information:
                This is a timer in minutes that will be set in
                		between calibrations.   If set to 0, 
                		it turns this calibration off. The range for the product
                		will be 0-10080. When you set to a value of 2 (min) or any 
                		other legal value other than 0, the device does not 
                		immediately begin calibrating when the timer expires.
                		The calibration takes place after the timer expires,
                		the next job has finished printing, and a 15 minute period
                	        of inactivity has passed."
::= { settings-prt-eng 23 }


marking-agent-density-setting OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or sets the marking agent density setting for each of		
                the marking agents installed. The Marking Agent (aka Print)		
                density is the instantaneous amount of marking agent applied to		
                the media while printing. A value of zero has the lowest print		
                density, yielding a lighter page. A value of 10 has the highest		
                print density, yielding a darker page. The device POS will		
                document what values are supported.
                Additional information:
                See the description for PRINT-DENSITY ."
::= { marking-agent-density 1 }


marking-agent-highlights-density-setting OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or sets the marking agent highlights density setting		
                for each of the marking agents installed. The value of this		
                object is in the range of -5..+5. The Marking Agent (aka Print)		
                density is the instantaneous amount of marking agent applied to		
                the media while printing. A value of -5 has the lowest print		
                density, yeilding a lighter pageA value of +5 the highest print		
                density, yielding a darker page."
::= { marking-agent-density 2 }


marking-agent-midtones-density-setting OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or sets the marking agent midtones density setting for		
                each of the marking agents installed. The value of this object		
                is in the range of -5..+5. See		
                MARKING-AGENT-HIGHLIGHTS-DENSITY-SETTING for a more specific		
                description."
::= { marking-agent-density 3 }


marking-agent-shadows-density-setting OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or sets the marking agent shadows density setting for		
                each of the marking agents installed. The value of this object		
                is in the range of -5..+5. See		
                MARKING-AGENT-HIGHLIGHTS-DENSITY-SETTING for a more specific		
                description."
::= { marking-agent-density 4 }


total-mono-page-count OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Total number of black pages printed by the device.
                Additional information:
                Total number of mono pages printed by the device."
::= { status-prt-eng 6 }


total-color-page-count OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Total number of color pages printed by the device.
                Additional information:
                Total number of color pages printed 
                				by the device."
::= { status-prt-eng 7 }


marker-density-calibration OBJECT-TYPE
    SYNTAX      INTEGER {
                          eNotCallibrating(1),
                          eCalibrateALL(2),
                          eCalibrateColorPlaneRegistration(5)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns the calibration status or triggers a calibration cycle.		
                All calibration procedures are used if set to eCalibrateALL. If		
                set to eCalibrateDMAX then a full density engine calibration is		
                triggered. If set to eCalibrateDHALF, then a Halftone		
                calibration is triggered.
                Additional information:
                Returns the calibration status or triggers a 
                				calibration cycle."
::= { settings-marking-agent 11 }


copier-token OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(1..128))
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Provides an advisory locking mechanism for hosts to coordinate		
                exclusive access to a copier device. Setting the object to a		
                unique id will only succeed if the token is currently set to 0.		
                The token is unlocked when it is set to 0. If the token is set		
                to a any value other than 0, then token is locked. If the token		
                was set to a unique id (locked), then an attempt to set (lock)		
                the token will fail. If the token was set to 0 (unlocked), then		
                an attempt to set (lock) the token will succeed in locking the		
                token. A get operation on COPIER-TOKEN will return its current		
                setting. The device does not prevent access to any objects. It		
                is assumed that hosts will be well behaved; respecting this		
                advisory locking mechanism by:    	
                    1) acquiring the lock before changing copier objects, and		
                           	
                    2) releasing the lock when done changing copier objects.		
                          
                Additional information:
                Provides an advisory locking mechanism for hosts to
                coordinate exclusive access.  Setting the object to a unique id
                will only succeed if the token is currently set to 0.  The token 
                is unlocked when it is set to 0. If the token is set to a any
                value other than 0, then token is locked.
                
                If the token was set to a unique id (locked), then an 
                attempt to set (lock) the token will fail.
                
                If the token was set to 0 (unlocked), then an attempt to set (lock)
                the token will succeed in locking the token.
                
                A get operation on COPY-TOKEN will return its current setting.
                The device does not prevent access to any objects.  It is assumed 
                that hosts will be well behaved; respecting this advisory locking 
                mechanism by:
                1) acquiring the lock before changing copy objects, and
                2) releasing the lock when done changing copy objects."
::= { settings-system 24 }


copy-scanner-dimensions OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "This object is used to obtain the exact pixel scan dimensions		
                for copy. The dimensions returned correspond to the quality,		
                reduce/enlarge, and media size currently selected.
                Additional information:
                This object is used to obtain the exact pixel scan dimensions for copy.
                			     The dimensions returned correspond to the quality, reduce/enlarge,
                			     and media size currently selected."
::= { status-scanner 13 }


copier-contrast OBJECT-TYPE
    SYNTAX      INTEGER(-127..127)
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Behaves as SCL's 'Set Scanner Contrast Level' command which is		
                used for setting the copier contrast level. Range is 0..100.
                Additional information:
                Behaves as SCL's 'Set Scanner Contrast Level' command
                which is used for setting the copier contrast level.  Contrast
                values can range from -127 to +127, for a total of 255 contrast 
                levels.  A positive value results in a larger difference, and a 
                negative value results in a smaller difference.  We support the 
                values -125, -100, -75, -50, -25, 0, 25, 50, 75, 100, 125.  
                We will map by snapping toward 0, to the closest device dependent 
                value if some other value is given. "
::= { settings-copier 2 }


copier-reduction OBJECT-TYPE
    SYNTAX      INTEGER(25..400)
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Percentage reduction desired for the copier. A value less than		
                or equal to zero is invalid. A value greater than 100		
                accomplishes magnification. A device is allowed to support a		
                set of values (documented in its POS), instead of the full		
                range. <OKNearestLegalValue Used> will be returned for		unsupported values greater than zero.
                Additional information:
                Percentage reduction desired for the copier.  A value less
                than or equal to zero is invalid.  A value greater than 100
                accomplishes magnification.  A device is allowed to support a set
                of values (documented in its POS), instead of the full range.
                <OKNearestLegalValueUsed> will be returned for unsupported valuesgreater than zero.
                Our default of 100 means no scaling"
::= { settings-copier 4 }


copier-num-copies OBJECT-TYPE
    SYNTAX      INTEGER(1..99)
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or changes the number of copies to be printed in the		
                next Host requested copy operation.
                Additional information:
                Returns or changes the number of copies to be printed in
                the next Host requested copy operation."
::= { settings-copier 6 }


copier-collation OBJECT-TYPE
    SYNTAX      INTEGER {
                          eCollateDisabled(1),
                          eCollateForward(2)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Enables the device with local copier capability that also		
                supports outputting multiple copies of a multi-paged source		
                document to print in a collated fashion.    	
                    eCollateDisabled - The collating feature of the copier		
                        device is not to be performed on subsequent copier		
                        operation.    	
                    eCollateForward - Copier device is to print multiple copies		
                        of the input document in such a way that the printed		
                        output order matches the source document.    	
                    eCollateReverse - Copier device is to print multiple copies		
                        of the input document such that the order of the		
                        printed output is in reverse order of the source		
                        document.   
                Additional information:
                Enables the device with local copier capability that
                also supports outputting multiple copies of a multi-
                paged source document to print in a collated fashion.
                eCollateDisabled - The collating feature of the copier
                device is not to be performed on subsequent copier
                operation.
                eCollateForward - Copier device is to print multiple
                copies of the input document in such a way that the
                printed output order matches the source document."
::= { settings-copier 7 }


copier-enlargement-maximum OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Maximum value that the host may set COPIER-REDUCTION to. A		
                value less than or equal to zero is invalid.
                Additional information:
                Maximum value that the host may set COPIER-REDUCTION or
                COPIER-JOB-REDUCTION to.
                A value less than or equal to zero is invalid."
::= { settings-copier 11 }


copier-reduction-maximum OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Minimum value that the host may set COPIER-REDUCTION to. A		
                value less than or equal to zero is invalid.
                Additional information:
                Minimum value that the host may set COPIER-REDUCTION or
                COPIER-JOB-REDUCTION to.
                A value less than or equal to zero is invalid."
::= { settings-copier 12 }


copier-quality OBJECT-TYPE
    SYNTAX      INTEGER {
                          eCopierQualityFast(1),
                          eCopierQualityNormal(2),
                          eCopierQualityPresentation(3),
                          eCopierQualityPicture(6),
                          eCopierQualityAutoSelect(7)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or sets the copier quality. This value is stored in		
                NVRAM, hence the value is saved over power cycles.
                Additional information:
                This value is stored in NVRAM, hence the value is
                saved over power cycles. 
                
                eCopierQualityFast is mapped to eCopierQualityNormal."
::= { settings-copier 13 }


copier-adf-page-count OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "This object tracks the page count for the pages scanned for		
                copying through the ADF. In order to write this object		
                SERVICE-PASSWORD must be set correctly.
                Additional information:
                  This object tracks the page count for pages 
                scanned for copying through the ADF.  This value is
                stored in the device NVRAM."
::= { settings-copier 19 }


copier-print-page-count OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "This object tracks the page count for the pages sent to the		
                print engine, for copy jobs. In order to write this object		
                SERVICE-PASSWORD must be set correctly.
                Additional information:
                  This object tracks the page count for pages sent to
                the print engine, for monochrome copy jobs.  This value is 
                stored in the device NVRAM."
::= { settings-copier 20 }


copier-job-media-size OBJECT-TYPE
    SYNTAX      INTEGER {
                          eUSLetter(2),
                          eUSLegal(3),
                          eISOandJISA4(26)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The user can set a copy job setting for paper size using the		
                COPIER-JOB-MEDIA-SIZE object, which is independent of other		
                functions in the device. The device behavior when the scanned		
                media and or print media do not match the value of this object		
                should be documented in the device POS. (for a full list of		
                media size enums see the end of this file) 
                Additional information:
                The default size for imaging a copy is 
                determined by reading the common device default paper size
                object.  The default for copy size cannot be changed 
                independently of other functions like fax and print.  The
                device will scan and format the print data based on the value
                of this object."
::= { settings-copier 21 }


copier-job-quality OBJECT-TYPE
    SYNTAX      INTEGER {
                          eCopierQualityFast(1),
                          eCopierQualityNormal(2),
                          eCopierQualityPresentation(3),
                          eCopierQualityPicture(6),
                          eCopierQualityAutoSelect(7)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or sets the copier quality.
                Additional information:
                Returns or sets the copier quality.
                eCopierQualityFast is supported but gets mapped to normal."
::= { settings-copier 22 }


copier-job-collation OBJECT-TYPE
    SYNTAX      INTEGER {
                          eCollateDisabled(1),
                          eCollateForward(2)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Enables the device with local copier capability that also		
                supports outputting multiple copies of a multi-paged source		
                document to print in a collated fashion. eCollateDisabled - The		
                collating feature of the copier device is not be performed on		
                subsequent copier operation. eCollateForward - Copier device is		
                to print multiple copies of the input document in such a way		
                that the printed output order matches the source document.		
                eCollateReverse - Copier device is to print multiple copies of		
                the input document such that the order of the printed output is		
                in reverse order of the source document. "
::= { settings-copier 23 }


copier-job-num-copies OBJECT-TYPE
    SYNTAX      INTEGER(1..99)
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or changes the number of copies to be printed in the		
                next Host requested copy operation."
::= { settings-copier 24 }


copier-job-reduction OBJECT-TYPE
    SYNTAX      INTEGER(25..400)
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Percentage reduction desired for the copier. A device is		
                allowed to support a set of values (documented in its POS),		
                instead of the full range. <OKNearesetLegalValueUsed> will be		
                returned for unsupported values.
                Additional information:
                A value less than or equal to zero is invalid.
                A value greater than 100 accomplishes magnification.  
                <OKNearestLegalValueUsed> will be returned for unsupported valuesgreater than zero.
                (default = 100 = no scaling)."
::= { settings-copier 25 }


copier-job-contrast OBJECT-TYPE
    SYNTAX      INTEGER(-127..127)
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Used to set the copier contrast level.
                Additional information:
                Behaves as SCL's 'Set Scanner Contrast Level' command
                which is used for setting the copier contrast level.  Contrast values
                can range from -127 to +127, for a total of 255 contrast levels.  
                The default contrast level is 0 (normal).  A positive value results
                in a larger difference, and a negative value results in a smaller
                difference.
                We support values of -125, -100, -75, -50, -25, 0, 25, 50, 75,
                100, 125.  The range of values we support is spread over a
                range such that a software product would support the standard spec,
                and we would map by snapping toward 0 to the closest device dependent 
                value."
::= { settings-copier 26 }


copier-job OBJECT-TYPE
    SYNTAX      INTEGER {
                          eCopierIdle(1),
                          eCopierStart(2),
                          eCopierActive(3),
                          eCopierAborting(4),
                          eCopierSetup(5)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Controls initiating and canceling a copy job.
                Additional information:
                Controls initiating and canceling a copy job.
                eCopierIdle : indicates that a copy function is not in progress.  
                - Device sets to this state from eCopierActive to signal successful 
                completion of copy operation.  
                - Device sets to this state from eCopierAborting to signal successful 
                cancel of copy operation.
                - Device sets to this state from eCopierStart to signal that the device is
                busy and cannot perform a copy operation.
                - Host sets to this state to indicate it wants to cancel the job.  Device
                will abort the job.
                
                eCopierSetup : indicates the host wants to set up job settings for a copy
                job.  Host sets to this state to then access copier job settings objects.
                Device does not set to this state.  Object can only transition to this state
                from eCopierIdle.
                
                eCopierStart - This state is set by host to request copy function initiation.
                Object can only transition to this state from eCopierSetup.
                To specify job settings host has to set to Setup first,
                send settings, then set to Start. Device should not set to this state.
                
                eCopierActive : indicates the copy function is in progress.  Device sets this
                state if the activity was started through front panel or if host request was
                successfully initiated.  Host should not set to this state.
                
                eCopierAborting : Set by device to indicate copy function was prematurely
                terminated, either by an error, or user canceled by pressing cancel button
                on device.  Device stays in this state until abort is complete, then moves to
                eCopierIdle. Host cannot set to this state, host sets to eCopierIdle to indicate
                it want to cancel the job. 
                
                - Device powers up in eCopierIdle. "
::= { settings-copier 27 }


default-copy-duplex-mode OBJECT-TYPE
    SYNTAX      INTEGER {
                          eSimplexToSimplex(1),
                          eSimplexToDuplexLongEdgeBinding(2)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or sets the duplex copying mode. Duplex printing is		
                when printing occurs on both sides of a sheet of media. Long		
                edge binding is also called vertical binding or book binding.		
                Short edge binding is also called horizontal binding or		
                calendar binding.   	
                    eSimplexToSimplex: takes image data from only one side of		
                        the original document, and print only on one side of		
                        each copy.    	
                    eSimplexToDuplexLongEdgeBinding: takes image data from only		
                        one side of the original document, and print to both		
                        sides of each copy. The images are rotated so that if		
                        the media is rotated along the axis of the long edge of		
                        the media, both images would appear as in the original.		
                           	
                    eSimplexToDuplexShortEdgeBinding: takes image data from		
                        only one side of the original document, and print to		
                        both sides of each copy. The images are rotated so that		
                        if the media is rotated along the axis of the short		
                        edge of the media, both images would appear as in the		
                        original.    	
                    eDuplexToDuplex: takes image data from both sides of the		
                        original document, and print on both sides of each		
                        copy.    	
                    eDuplexToSimplexLongEdgeBinding: takes image data from both		
                        sides of the original document, and prints to only one		
                        side of each copy. The images are rotated so that if		
                        the media is rotated along the axis of the long edge of		
                        the media, both images would appear as in the original.		
                           	
                    eDuplexToSimplexShortEdgeBinding: takes image data from		
                        both sides of the original document, and prints to only		
                        one side of each copy. The images are rotated so that		
                        if the media is rotated along the axis of the short		
                        edge of the media, both images would appear as in the		
                        original.   
                Additional information:
                Returns or sets the duplex copying mode. Duplex printing is		
                when printing occurs on both sides of a sheet of media. Long		
                edge binding is also called vertical binding or book binding.		
                Short edge binding is also called horizontal binding or		
                calendar binding.   	
                eSimplexToSimplex: takes image data from only one side of		
                the original document, and print only on one side of		
                each copy.    	
                eSimplexToDuplexLongEdgeBinding: takes image data from only		
                one side of the original document, and print to both		
                sides of each copy. The images are rotated so that if		
                the media is rotated along the axis of the long edge of		
                the media, both images would appear as in the original.		
                	
                eSimplexToDuplexShortEdgeBinding: takes image data from		
                only one side of the original document, and print to		
                both sides of each copy. The images are rotated so that		
                if the media is rotated along the axis of the short		
                edge of the media, both images would appear as in the		
                original.    	
                eDuplexToDuplex: takes image data from both sides of the		
                original document, and print on both sides of each		
                copy.    	
                eDuplexToSimplexLongEdgeBinding: takes image data from both		
                sides of the original document, and prints to only one		
                side of each copy. The images are rotated so that if		
                the media is rotated along the axis of the long edge of		
                the media, both images would appear as in the original.		
                	
                eDuplexToSimplexShortEdgeBinding: takes image data from		
                both sides of the original document, and prints to only		
                one side of each copy. The images are rotated so that		
                if the media is rotated along the axis of the short		
                edge of the media, both images would appear as in the		
                original.   
                If duplex print has been disabled the object will return an error
                for pmlsets on eSimplexToDuplexLongEdgeBinding(2) and
                eDuplexToDuplex(4).  If duplex scan has been disabled it will 
                return an error  for pmlsets on eDuplexToDuplex(4) and
                eDuplexToSimplexLongEdgeBinding(5).If the device has both disabled  
                or the features is are present, such as on a kiwi, both pmlsets and 
                pmlgets will return an error for all enumerations."
::= { settings-copier 28 }


copier-flatbed-page-count OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "This object tracks the page count for the pages scanned for		
                copying from the flatbed. In order to write this object		
                SERVICE-PASSWORD must be set correctly.
                Additional information:
                  This object tracks the page count for pages
                scanned for copying from the flatbed.  This value is
                stored in the device NVRAM."
::= { settings-copier 44 }


copier-pages-per-sheet OBJECT-TYPE
    SYNTAX      INTEGER {
                          ePagesPerSheet1(1)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or sets the copier number of input pages per output		
                sheet. This is also known as nup. This value is stored in		
                NVRAM, hence the value is saved over power cycles.
                Additional information:
                Enables the device with local copier capability that
                also supports outputting multiple copies of a multi-
                paged source document to print multiple input sheets onto
                a single output sheet.
                ePagesPerSheet_1: A single input image is placed on a
                single output sheet.  This basically has no affect.
                ePagesPerSheet_2: Two input images are placed on a
                single output sheet, in landscape format.
                ePagesPerSheet_4: Four input images are placed on
                a single output sheet, in portrait format.
                NOTE: The Pages Per Sheet feature will only be supported
                on devices with an ADF.  If no ADF is present, then
                changes to this object will not be allowed."
::= { settings-copier 45 }


copier-job-pages-per-sheet OBJECT-TYPE
    SYNTAX      INTEGER {
                          ePagesPerSheet1(1)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or sets the copy value for how many input pages per		
                output sheet.
                Additional information:
                Enables the device with local copier capability that
                also supports outputting multiple copies of a multi-
                paged source document to print multiple input sheets onto
                a single output sheet.
                ePagesPerSheet1: A single input image is placed on a
                single output sheet.  This basically has no affect.
                ePagesPerSheet2: Two input images are placed on a
                single output sheet, in landscape format.
                ePagesPerSheet4: Four input images are placed on
                a single output sheet, in portrait format.
                NOTE: The Pages Per Sheet feature will only be supported
                on devices with an ADF.  If no ADF is present, then
                changes to this object will not be allowed."
::= { settings-copier 46 }


copier-fit-to-page OBJECT-TYPE
    SYNTAX      INTEGER {
                          eFitToPageEnabled(2)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or sets the copy setting for fit to page. This value is		
                stored in NVRAM, hence the value is saved over power cycles.
                Additional information:
                Enables the device with local copier capability to
                fit the input image size automatically onto the output sheet
                size."
::= { settings-copier 47 }


copier-job-fit-to-page OBJECT-TYPE
    SYNTAX      INTEGER {
                          eFitToPageEnabled(2)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or sets the copy value for fit to page.
                Additional information:
                Enables the device with local copier capability to
                fit the input image size automatically onto the output sheet
                size."
::= { settings-copier 48 }


copier-pages-per-sheet-maximum OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Maximum pages per sheet value supported by the COPIER-		
                PAGES-PER-SHEET and COPIER-JOB-PAGES-PER-SHEET objects. A value		
                less than or equal to zero is invalid.
                Additional information:
                Maximum value supported for COPIER-PAGES-PER-SHEET or
                COPIER-JOB-PAGES-PER-SHEET objects. 
                A value less than or equal to zero is invalid."
::= { settings-copier 49 }


device-cfg-download OBJECT-TYPE
    SYNTAX      INTEGER {
                          eCfgDownloadIdle(1),
                          eCfgDownloadStart(2),
                          eCfgDownloadActive(3),
                          eCfgDownloadAborted(4),
                          eCfgDownloadDone(5)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Handshaking mechanism between host and device to coordinate the		
                download of device specific data.    	
                    eCfgDownloadIdle - indicates device configuration download		
                        activity is not occurring. Device powers up in this		
                        state but will otherwise never transition to this		
                        state. This state is host settable from		
                        eCfgDownloadActive, eCfgDownloadDone, and		
                        eCfgDownloadAborted. Host setting to eCfgDownloadIdle		
                        while object is in eCfgDownloadActive will cause the		
                        download activity to be prematurely terminated. Host		
                        setting to this state resets the object to permit		
                        another download activity to be initiated.    	
                    eCfgDownloadStart - indicates host wishes to commence a		
                        device configuration download activity. This state is		
                        only host settable from eCfgDownloadIdle. Only the		
                        device can transition this object from this state to		
                        eCfgDownloadActive or eCfgDownloadAborted. Device will		
                        not set to this state.    	
                    eCfgDownloadActive - indicates download activity is in		
                        progress. Device transitions object to this state only		
                        from eCfgDownloadStart, to signal data download can		
                        commence. The device can transition from this state to		
                        eCfgDownloadDone or eCfgDownloadAborted. The host can		
                        transition from this state to eCfgDownloadIdle. This		
                        state is not host settable.    	
                    eCfgDownloadAborted - indicates the download activity was		
                        terminated by the device. Only the device can set to		
                        this state from eCfgDownloadStart or		
                        eCfgDownloadActive. Only the host can transition from		
                        this state to eCfgDownloadIdle. This state is not host		
                        settable.    	
                    eCfgDownloadDone - indicates device has completely received		
                        the download data. Device transitions to this state		
                        only from eCfgDownloadActive. Only the host can		
                        transition from this state to eCfgDownloadIdle. This		
                        state is not host settable.   "
::= { settings-system 11 }


device-cfg-download-data-type OBJECT-TYPE
    SYNTAX      INTEGER {
                          eSpeedDials(5),
                          eFaxLogs(6),
                          eConfigPrams(7),
                          eJunkFaxDialStrings(9)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Indicates the type of device specific data to be downloaded."
::= { settings-system 12 }


device-cfg-upload OBJECT-TYPE
    SYNTAX      INTEGER {
                          eCfgUploadIdle(1),
                          eCfgUploadStart(2),
                          eCfgUploadActive(3),
                          eCfgUploadAborted(4),
                          eCfgUploadDone(5)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Handshaking mechanism between host and device to coordinate the		
                upload of device specific data.    	
                    eCfgUploadIdle - indicates device configuration upload		
                        activity is not occurring. Device powers up in this		
                        state but will otherwise never transition to this		
                        state. This state is host settable from		
                        eCfgUploadActive, eCfgUploadDone, and		
                        eCfgUploadAborted. Host setting to eCfgUploadIdle while		
                        object is in eCfgUploadActive will cause the upload		
                        activity to be prematurely terminated. Host setting to		
                        this state resets the object allowing a new upload to		
                        be initiated.    	
                    eCfgUploadStart - indicates host wishes to commence a		
                        device configuration upload activity. This state is		
                        only host settable from eCfgUploadIdle. Only the device		
                        can transition this object from this state to		
                        eCfgUploadActive or eCfgUploadAborted. Device will not		
                        set to this state.    	
                    eCfgUploadActive - indicates upload activity is in		
                        progress. Device transitions object to this state only		
                        from eCfgUploadStart, to signal data upload can		
                        commence. The device can transition from this state to		
                        eCfgUploadDone or eCfgUploadAborted. The host can		
                        transition from this state to eCfgUploadIdle. This		
                        state is not host settable.    	
                    eCfgUploadAborted - indicates the upload activity was		
                        terminated by the device. Only the device can set to		
                        this state from eCfgUploadStart or eCfgUploadActive.		
                        Only the host can transition from this state to		
                        eCfgUploadIdle. This state is not host settable.    	
                    eCfgUploadDone - indicates device completely transmitted		
                        the upload data. Device transitions to this state only		
                        from eCfgUploadActive. Only the host can transition		
                        from this state to eCfgUploadIdle. This state is not		
                        host settable.   "
::= { settings-system 13 }


device-cfg-upload-data-type OBJECT-TYPE
    SYNTAX      INTEGER {
                          eSpeedDials(5),
                          eFaxLogs(6),
                          eConfigPrams(7),
                          eJunkFaxDialStrings(9)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Indicates the type of device specific data to be uploaded."
::= { settings-system 14 }


download-timeout OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Specifies the number of seconds that device will wait for data		
                from the host before the device determines the host is being		
                unresponsive. This timeout condition may cause the device to		
                take recourse action regarding the disposition of the download		
                activity. A value of zero indicates device will wait forever		
                for the host data. POS should indicate whether this object		
                value, when set by the host, is remembered between device power		
                cycles.
                Additional information:
                This object is volatile and as such will not be
                retained by the device between power cycles."
::= { settings-system 17 }


upload-timeout OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Specifies the number of seconds that device will wait for		
                response from the host after transmitting a unit of data before		
                the device determines the host is being unresponsive. This		
                timeout condition may cause the device to take recourse action		
                regarding the disposition of the upload activity. A value of		
                zero indicates device will wait forever for the host response.		
                POS should indicate whether this object value, when set by the		
                host, is remembered between device power cycles
                Additional information:
                This object is volatile and as such will not be
                retained by the device between power cycles."
::= { settings-system 18 }


date-display OBJECT-TYPE
    SYNTAX      INTEGER {
                          eDateDisplayMMDDYY(1),
                          eDateDisplayDDMMYY(2),
                          eDateDisplayYYMMDD(3)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Controls front-panel date display format.
                Additional information:
                Controls front-panel date display format."
::= { settings-system 22 }


device-cfg-param-command OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "A C structure containing the following fields:    typedef		
                struct {    	
                    u8bit list_id;    	
                    s8bit auto_incr;    	
                    u16bit max_index;    	
                    u16bit rec_size;    	
                    u16bit index;    	
                    u8bit data[];    	
                    } PML_device_cfg_param_cmd_t;    	
                where u8bit is an unsigned byte (0..255), s8bit is a signed		
                byte (-128..127), and u16bit is an big endian format unsigned		
                short (0..65535). The POS should state which list_id's the		
                device supports.
                Additional information:
                This LaserJet MFP supports two values for list_id:  
                0 for configuration parameters and   
                1 for default configuration parameters."
::= { settings-system 23 }


fax-upload-token OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(1..128))
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Provides an advisory locking mechanism for hosts to coordinate		
                exclusive access to the fax upload features of a device.		
                Setting the object to a unique id will only succeed if the		
                token is currently set to 0. The token is unlocked when it is		
                set to 0. If the token is set to a any value other than 0, then		
                token is locked. If the token was set to a unique id (locked),		
                then an attempt to set (lock) the token will fail. If the token		
                was set to 0 (unlocked), then an attempt to set (lock) the		
                token will succeed in locking the token. A get operation on		
                FAX-UPLOAD-TOKEN will return its current setting. The device		
                does not prevent access to any objects. It is assumed that		
                hosts will be well behaved; respecting this advisory locking		
                mechanism by:    	
                    1) acquiring the lock before changing any fax-upload		
                        objects, and    	
                    2) releasing the lock when done changing scan objects.   
                Additional information:
                Provides an advisory locking mechanism for hosts to
                coordinate exclusive access.  Setting the object to a unique id
                will only succeed if the token is currently set to 0.  The token 
                is unlocked when it is set to 0. If the token is set to a any
                value other than 0, then token is locked.
                
                If the token was set to a unique id (locked), then an 
                attempt to set (lock) the token will fail.
                
                If the token was set to 0 (unlocked), then an attempt to set (lock)
                the token will succeed in locking the token.
                
                A get operation on FAX-UPLOAD-TOKEN will return its current setting.
                The device does not prevent access to any objects.  It is assumed 
                that hosts will be well behaved; respecting this advisory locking 
                mechanism by:
                1) acquiring the lock before changing fax objects, and
                2) releasing the lock when done changing fax objects."
::= { settings-system 26 }


fax-download-token OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(1..128))
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Provides an advisory locking mechanism for hosts to coordinate		
                exclusive access to the fax download features of a device.		
                Setting the object to a unique id will only succeed if the		
                token is currently set to 0. The token is unlocked when it is		
                set to 0. If the token is set to a any value other than 0, then		
                token is locked. If the token was set to a unique id (locked),		
                then an attempt to set (lock) the token will fail. If the token		
                was set to 0 (unlocked), then an attempt to set (lock) the		
                token will succeed in locking the token. A get operation on		
                FAX-DOWNLOAD-TOKEN will return its current setting. The device		
                does not prevent access to any objects. It is assumed that		
                hosts will be well behaved; respecting this advisory locking		
                mechanism by:    	
                    1) acquiring the lock before changing any fax-download		
                        objects, and    	
                    2) releasing the lock when done changing scan objects.   
                Additional information:
                Provides an advisory locking mechanism for hosts to
                coordinate exclusive access.  Setting the object to a unique id
                will only succeed if the token is currently set to 0.  The token 
                is unlocked when it is set to 0. If the token is set to a any
                value other than 0, then token is locked.
                
                If the token was set to a unique id (locked), then an 
                attempt to set (lock) the token will fail.
                
                If the token was set to 0 (unlocked), then an attempt to set (lock)
                the token will succeed in locking the token.
                
                A get operation on FAX-DOWNLOAD-TOKEN will return its current setting.
                The device does not prevent access to any objects.  It is assumed 
                that hosts will be well behaved; respecting this advisory locking 
                mechanism by:
                1) acquiring the lock before changing fax objects, and
                2) releasing the lock when done changing fax objects."
::= { settings-system 27 }


date-and-time OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "A C structure containing the following fields:    typedef		
                struct {    	
                    ubyte yr; /* year: 0 to 99 */    	
                    ubyte mon; /* month: 1 to 12 */    	
                    ubyte day; /* day: 1 to 31 */    	
                    ubyte wday; /* Day of week: 1 to 07 */    	
                    ubyte hr; /* hour: 0 to 23 */    	
                    ubyte min; /* minute: 0 to 59 */    	
                    ubyte sec; /* second: 0 to 59 */    	
                    } date_t;    	
                where ubyte is an unsigned byte (0-255)."
::= { status-system 17 }


time-display OBJECT-TYPE
    SYNTAX      INTEGER {
                          eTimeDisplayTwelveHour(1),
                          eTimeDisplayTwentyFourHour(2)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Controls front-panel time display format. Set to		
                eTimeDisplayTwelveHour for AM/PM display. Set to		
                eTimeDisplayTwentyFourHour for military-type display."
::= { status-system 28 }


device-cfg-download-error OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Error status of the configuration download session. POS should		
                indicate the actual error values reserving value 0 as NO		
                ERROR.
                Additional information:
                A value of 0 indicates NO ERROR."
::= { status-system 43 }


device-cfg-upload-error OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Error status of the configuration upload session. POS should		
                indicate the actual error values reserving value 0 as NO		
                ERROR.
                Additional information:
                A value of 0 indicates NO ERROR."
::= { status-system 45 }


fax-local-phone-num OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "CCITT sender's station id (ex. 08-396-4122)."
::= { id 8 }


fax-station-name OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "name for the fax device (ex. HP R&D)."
::= { id 9 }


fax-line-interface-unit-id OBJECT-TYPE
    SYNTAX      INTEGER(0..8)
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The fax device line interface unit (LIU) identifier. The LIU		
                number identifies the telephone system electrical		
                characteristics supported by this device.
                Additional information:
                In this LaserJet MFP this value is stored in 3 bits on the
                LIU."
::= { id 18 }


faxjob-action OBJECT-TYPE
    SYNTAX      INTEGER {
                          ePrintFaxToPrinter(1),
                          eDeleteFaxFromMemory(3)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Permits host to specify an action to be applied with a		
                particular fax."
::= { settings-fax-job 1 }


faxjob-action-id OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Contains the fax job identification of the fax to be acted upon		
                by the action specified by the object FAXJOB-ACTION."
::= { settings-fax-job 2 }


faxjob-tx-type OBJECT-TYPE
    SYNTAX      INTEGER {
                          eSrcHostOnly(2),
                          eSrcScannerOnly(5),
                          eSrcHostToMemoryOnly(9)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Indicates sources of the fax image for transmission. Also		
                specifies the temporal order of the data sources.    	
                    eSrcHostOnly - The fax document images will be wholly		
                        downloaded from the host.    	
                    eSrcScannerOnly - The fax document images originate wholly		
                        from the device scanner/ADF subsystem.    	
                    eSrcHostThenScanner - The fax document is composed of		
                        images downloaded from the host and pages from the		
                        scanner/ADF subsystem. The host downloaded pages will		
                        be faxed first, followed by the pages in the		
                        scanner/ADF.   	
                    eSrcScannerThenHost - The fax document is composed of pages		
                        in the scanner/ADF and the images downloaded from the		
                        host. The document in the ADF is faxed first, followed		
                        by the pages downloaded from the host.    	
                    eSrcHostThenMemory - The fax document is composed of pages		
                        downloaded from the host and images already stored		
                        within the device. The fax transmission will contain		
                        the host downloaded pages followed by the images in the		
                        device memory.    	
                    eSrcHostToMemoryOnly - Permits fax images to be downloaded		
                        into device memory for later use with		
                        eSrcHostThenMemory.   
                Additional information:
                eSrcHostToMemoryOnly is included for
                development and testing only.  eSrcHostToMemoryOnly will
                not be an allowed value for this object in the released
                product."
::= { settings-fax-job 3 }


faxjob-download-id OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Contains the device assigned job identification for the current		
                fax downloading job. The job ID is monotonically increasing		
                number. The job ID may be reset to zero or may roll over to		
                zero after reaching some maximum. The maximum value before the		
                rollover should be stated in the POS. 
                Additional information:
                The maximum value before this object rolls over
                to 0 is 2,147,483,648.  Behavior of this object once
                the value rolls over to 0 is not specified."
::= { status-fax-job 1 }


faxjob-rx-id OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Contains the device assigned job identification for the		
                currently fax reception job. The job ID is monotonically		
                increasing number. The job ID may be reset to zero or may roll		
                over to zero after reaching some maximum. The maximum value		
                before the rollover should be stated in the POS. 
                Additional information:
                The maximum value before this object rolls over
                to 0 is 2,147,483,648.  Behavior of this object once
                the value rolls over to 0 is not specified."
::= { status-fax-job 2 }


faxjob-tx-id OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Contains the device assigned job identification for the current		
                fax transmission job. The job ID is monotonically increasing		
                number. The job ID may be reset to zero or may roll over to		
                zero after reaching some maximum. The maximum value before the		
                rollover should be stated in the POS. 
                Additional information:
                The maximum value before this object rolls over
                to 0 is 2,147,483,648.  Behavior of this object once
                the value rolls over to 0 is not specified."
::= { status-fax-job 3 }


faxjob-upload-id OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Contains the device assigned job identification for the current		
                fax upload job. The job ID is monotonically increasing number.		
                The job ID may be reset to zero or may roll over to zero after		
                reaching some maximum. The maximum value before the rollover		
                should be stated in the POS.
                Additional information:
                The maximum value before this object rolls over
                to 0 is 2,147,483,648.  Behavior of this object once
                the value rolls over to 0 is not specified."
::= { status-fax-job 4 }


faxjob-rx-status-1 OBJECT-TYPE
    SYNTAX      INTEGER {
                          eFaxRxIdle(1),
                          eFaxRxRinging(2),
                          eFaxRxAnswering(3),
                          eFaxRxReceiving(4)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Status of receiving fax session 1."
::= { faxjob-rx-status 1 }


faxjob-tx-status-1 OBJECT-TYPE
    SYNTAX      INTEGER {
                          eFaxTxIdle(1),
                          eFaxTxDialing(2),
                          eFaxTxConnecting(3),
                          eFaxTxTransmitting(4)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Status of sending fax session 1."
::= { faxjob-tx-status 1 }


faxjob-tx-error-1 OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Error status of the fax reception session 1.
                Additional information:
                Error status of the fax transmission session 1."
::= { faxjob-tx-error 1 }


faxjob-tx-current-page-1 OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The page number of the fax page currently being transmitted via		
                send fax session 1. Starts with page number 1."
::= { faxjob-tx-current-page 1 }


faxjob-rx-current-page-1 OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The page number of the fax page currently being received via		
                fax reception session 1. Starts with page number 1."
::= { faxjob-rx-current-page 1 }


faxjob-rx-duration-1 OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Represent the number of seconds of phone-connect time for a fax		
                reception session 1."
::= { faxjob-rx-duration 1 }


faxjob-tx-duration-1 OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Represent the number of seconds of phone-connect time for send		
                fax session 1."
::= { faxjob-tx-duration 1 }


fax-log-action OBJECT-TYPE
    SYNTAX      INTEGER {
                          eIdle(1),
                          eClear(2),
                          ePrintLatest(3),
                          ePrintAll(4)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Provides applications with the ability to clear or print the		
                fax transaction log. eIdle - no action is occurring on the fax		
                log. eClear - clear the fax log. ePrintLatest - print the		
                latest entry in the fax log. ePrintAll - print all the entries		
                in the fax log. When this object is set to a non-eIdle value by		
                an application, the given action starts. When the action is		
                complete, this object is changed back to eIdle by the device. A		
                host's request to write this object will be rejected when the		
                object is not eIdle. When eIdle, the host may set the object to		
                any value (including eIdle)."
::= { settings-faxlog 1 }


fax-log-reporting OBJECT-TYPE
    SYNTAX      INTEGER {
                          eNever(1),
                          eErrorOnly(2),
                          eSendOnly(3)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Specifies when fax transaction logs are to be printed."
::= { settings-faxlog 2 }


fax-dial-mode OBJECT-TYPE
    SYNTAX      INTEGER {
                          eToneDial(1),
                          ePulseDial(2)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Device should use DTMF dialing if eToneDial, pulse dial if		
                ePulseDial."
::= { dial-all-lines 1 }


device-redial OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Device to permit redial upon detecting certain error		
                conditions."
::= { dial-all-lines 2 }


fax-pulse-dial-support OBJECT-TYPE
    SYNTAX      INTEGER {
                          eSupported(1),
                          eNotSupported(2)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "This object reports whether the current set country supports		
                pulse dial.
                Additional information:
                This object reports whether the current set country supports pulse
                dial.  In this LaserJet MFP, it checks the DS variable, which is updated
                		when the pml object FAX-COUNTRY is changed."
::= { dial-all-lines 3 }


fax-answer-mode OBJECT-TYPE
    SYNTAX      INTEGER {
                          eManualAnswer(1),
                          eFaxAnswer(2),
                          eTadAnswer(3),
                          eFaxTelAnswer(4)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Sets the answering-priority when using a shared voice line.		
                eManualAnswer - Device will not automatically answer the phone.		
                User must answer and push START button. eFaxAnswer - Device		
                should assume call is fax, send CED immediately upon answering.		
                eTadAnswer - (Telephone Answering Device Mode) Device allows		
                downstream TAD to answer but device will eavesdrop for fax CNG		
                signal. If a CNG detected, cut off the downstream device, send		
                CED. Do nothing if CNG not detected."
::= { answer-all-lines 1 }


fax-num-rings-pickup OBJECT-TYPE
    SYNTAX      INTEGER(1..6)
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Number of rings before the fax device answers the phone if		
                FAX-ANSWER-MODE is not set to MANUAL-MODE."
::= { answer-all-lines 2 }


device-ring-type-pickup OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Device to answer the incoming call based on detecting the the		
                specified type of telephone ring."
::= { answer-all-lines 3 }


fax-receive-stamping-enable OBJECT-TYPE
    SYNTAX      INTEGER {
                          eDisabled(1),
                          eEnabled(2)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Controls whether or not incoming pages of a fax will be stamped		
                upon receipt. Content of the stamp is device-specific but may		
                include such information as date, time, fax station name, and		
                page number. When this object is set to eEnabled each page of		
                an incoming fax is stamped by the device. When this object is		
                set to eDisabled incoming fax pages are not stamped.
                Additional information:
                When this object is set to eEnabled each page of an
                incoming fax is stamped with the date, time, fax station
                name, and page number.  When this object is set to
                eDisabled incoming fax pages are not stamped.
                //
                The received fax page will be scaled down 0.03% to
                accomodate the header. No header will be printed on 
                page 2 of paginated output."
::= { settings-fax-receive 1 }


not-ready-fax-receive OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Indicates if the receiving fax sub-system in the device is not		
                ready. If there are no items in the collection (i.e. no bits		
                are set), then the receiving fax sub-system is ready. If there		
                is an item present, then the item indicates what is causing the		
                receiving fax sub-system to be not ready."
::= { status-fax-receive 1 }


fax-rxscale OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Received faxes are to be printed at a reduced scale percentage.		
                Value of 0 indicates auto-scaled printing based on the length		
                of the received fax image and the length of the paper."
::= { settings-fax-proc-sub 1 }


fax-noise-volume OBJECT-TYPE
    SYNTAX      INTEGER(0..200)
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Range is 0..100, where 0 = quietest possible, and 100 = loudest		
                possible. A device shall divide this value into ranges		
                corresponding to the possible volumes.
                Additional information:
                For this LaserJet MFP the range is 0..200, where 0=off (silent), 
                30=soft, 80=medium, and 180=loud.
                
                For this  LaserJet MFP this object refers to the line monitor 
                noise volume. The decimal values above correspond
                		to the hex values the object gets set to."
::= { settings-fax-proc-sub 3 }


fax-download OBJECT-TYPE
    SYNTAX      INTEGER {
                          eFaxDownloadIdle(1),
                          eFaxDownloadStart(2),
                          eFaxDownloadActive(3),
                          eFaxDownloadAborted(4),
                          eFaxDownloadDone(5)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Note: Changed enumeration values in a non-backwards manner in		
                version 4.7. Handshake mechanism between host and device to		
                initiate and coordinate the download of fax image data to be		
                transmitted by the device fax modem. This object serves both as		
                an indicator of fax download activity as well as a trigger for		
                the host to alter fax download progress. This object has been		
                redefined to track only the download acpect of the fax		
                transmission.    	
                    eFaxDownloadIdle - indicates no fax download activity is		
                        occurring. Device powers up in this state but will		
                        otherwise never transition to this state of its own		
                        accord. Host setting to eFaxDownloadIdle while object		
                        is in eFaxDownloadActive will cause download activity		
                        to be prematurely terminated. Host setting to this		
                        state resets the handshake mechanism to permit a		
                        another fax download activity to be initiated.    	
                    eFaxDownloadStart - indicates the host requests to commence		
                        a download session for sending a fax. This state is		
                        host settable only from eFaxDownloadIdle. Device will		
                        never transition to this state of its own accord.    	
                    eFaxDownloadActive - indicates a fax download is occurring.		
                        This state is not host settable. Device will transition		
                        to this state from eFaxDownloadStart as a positive		
                        response for host to commence download of fax data.		
                        This state is not host settable. The object		
                        FAXJOB-DOWNLOAD-ID now contains the job ID to be used		
                        to track the progress of this fax job.    	
                    eFaxDownloadAborted - indicates the fax download activity		
                        has been prematurely terminated by the device due to		
                        some error. Object FAX-DOWNLOAD-ERROR contains the		
                        error reason for the premature session termination.		
                        This state is device settable from eFaxDownloadStart or		
                        eFaxDownloadActive. This state is not host settable. If		
                        modem transmission of fax data has started for this		
                        download, the fax session will also be aborted.    	
                    eFaxDownloadDone - indicates the fax download activity has		
                        reached a successful termination in that the device has		
                        accepted all the download data from the host. This		
                        state is only settable by the device from		
                        eFaxDownloadActive. This state is not host settable.   	                         
                This state does not indicate the progress of the modem		
                transmission of the downloaded fax data. Host should transition		
                from this state to eFaxDownloadIdle in order to reset the		
                handshake mechanism for subsequent download."
::= { settings-fax-proc-sub 6 }


fax-silent-detection OBJECT-TYPE
    SYNTAX      INTEGER {
                          eDisabled(1),
                          eEnabled(2)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "When enabled, this object causes the FAX machine to assume that		
                the caller is a FAX even though the line has remained silent		
                for a time (i.e., no CNG detected). When disabled, a CNG is		
                required of the caller."
::= { settings-fax-proc-sub 7 }


fax-ring-enable OBJECT-TYPE
    SYNTAX      INTEGER {
                          eDisabled(1),
                          eEnabled(2)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "When the phone line rings, this object determines whether an		
                audible ring shall be emitted."
::= { settings-fax-proc-sub 8 }


fax-country OBJECT-TYPE
    SYNTAX      INTEGER {
                          eChina(6),
                          eMexicoAndLatinAmerica(13),
                          eCanadaFrench(14),
                          eUnitedStatesAndCanadaEnglish(15),
                          eNewZealand(19),
                          eIsrael(21),
                          eAustralia(23),
                          eMalaysia(27),
                          eHongKong(29),
                          eSingapore(30),
                          eUnitedKingdom(31),
                          eAustria(34),
                          eNetherlands(35),
                          eSwitzerlandFrench(37),
                          eGermany(39),
                          eDenmark(40),
                          eSweden(41),
                          eNorway(43),
                          eIreland(44),
                          eBelgium(45),
                          eFinland(46),
                          eFrance(47),
                          eItaly(51),
                          eSpain(55),
                          ePoland(56),
                          eHungary(62),
                          eUkraine(63),
                          eRussia(64),
                          eBelarus(66),
                          eBrunei(33),
                          eCambodia(94),
                          eCyprus(95),
                          eEgypt(67),
                          eEstonia(54),
                          eIceland(96),
                          eLatvia(53),
                          eLiechtentstein(98),
                          eLithuania(52),
                          eMalta(99),
                          eMorocco(65),
                          eSaudiArabia(28),
                          eTunisia(32),
                          eUAE(88)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Note: Non-backwards compatible change make in version 4.7.		
                Returns which country the telephone-electronics (LIU) is		
                configured for.    	
                    If this object is implemented with an access of read-write		
                        the device POS will specify what occurs when this		
                        object is written.   "
::= { settings-fax-proc-sub 9 }


fax-tx-phone-number OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      write-only
    STATUS      optional
       DESCRIPTION "Phone number about to be dialed."
::= { settings-fax-proc-sub 10 }


fax-redial-time OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Number of seconds one must wait between the current redial (set		
                by FAX-WHICH-REDIAL) and any prior dialing."
::= { settings-fax-proc-sub 14 }


fax-pstn-access-code OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The code used within a PBX to get access to an outside PSTN		
                line. Typically this is ''9''."
::= { settings-fax-proc-sub 18 }


fax-rx-disposition OBJECT-TYPE
    SYNTAX      INTEGER {
                          ePrintOnly(1),
                          eUploadOnly(2),
                          eUploadElsePrint(4),
                          eForwardElsePrint(6)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Indicates what is to be done with the incoming fax call.    	
                    ePrintOnly - New fax arrivals only go to the printer. If		
                        printer becomes unavailable, the fax is stored in		
                        device memory until the printer becomes available. If		
                        device memory becomes full, no subsequent calls will be		
                        answered. If power is cycled on the device, the user		
                        must be informed of any lost faxes. If faxes are saved		
                        in non-volatile memory, then they will be printed upon		
                        successful power-up.    	
                    eUploadOnly - New fax can only be uploaded to the host. If		
                        host becomes unavailable, the fax is stored in device		
                        memory until host becomes available again to upload. If		
                        device memory becomes full, no subsequent calls will be		
                        answered. If power is cycled on the device, the user		
                        must be informed of any lost faxes. If faxes are saved		
                        in non-volatile device memory, the host must be		
                        informed of a need to upload saved faxes upon		
                        successful power up.    	
                    eUploadAndPrint - Received faxes are to be printed and also		
                        uploaded to the host. The fax is stored in device		
                        memory until it has been printed and uploaded. If		
                        device memory becomes full, no subsequent calls will be		
                        answered. If power is cycled on the device, the user		
                        must be informed of any lost faxes. If faxes were saved		
                        into non-volatile memory, then faxes must be printed		
                        and uploaded before erasure from device memory.    	
                    eUploadElsePrint - Received faxes are to be uploaded if		
                        host is available, otherwise the fax is printed. During		
                        an upload, if the host becomes unavailable, the		
                        remainder of the fax is printed. Once the host is		
                        detected to be unavailable, the object will transition		
                        to ePrintOnly. Refer to fax reception behavior for		
                        ePrintOnly.    	
                    ePrintElseUpload - Received faxes are to be printed. If		
                        printer is unavailable, the fax will be uploaded. If		
                        printer becomes unavailable while the fax is being		
                        received, the remainder unprinted pages of the fax will		
                        be uploaded. If host then becomes unavailable, this		
                        object will transition to ePrintOnly. Remainder pages		
                        of the fax being uploaded will be stored in device		
                        memory, to be printed when printer becomes available.		
                        If device memory becomes full, no subsequent calls will		
                        be answered. If power is cycled on the device, the user		
                        must be informed of any lost faxes.    	
                    eForwardElsePrint - Received faxes are to be forwarded to		
                        another fax station. If remote number does not answer,		
                        fax is printed. If remote number is busy on multiple		
                        redial attempts, the fax is printed. If device memory		
                        becomes full before fax reception is complete, the fax		
                        is printed. If printer becomes unavailable, the fax is		
                        stored in device memory and then printed when printer		
                        becomes available again.   "
::= { settings-fax-proc-sub 19 }


fax-error-correction-mode OBJECT-TYPE
    SYNTAX      INTEGER {
                          eDisabled(1),
                          eEnabled(2)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Indicates whether the device is configured to send and receive		
                faxes in error correction mode (ECM). This object controls both		
                receiving and transmitting in ECM. A value of eDisabled means		
                ECM is off and the device will not advertise the ability to do		
                ECM during negotiation with other fax machines. A value of		
                eEnabled means ECM is on and the device will advertise its		
                ability to do ECM. Changing this setting may or may not take		
                affect on the immediate page or ensuing pages of the document		
                currently being sent."
::= { settings-fax-proc-sub 21 }


fax-report-transmission OBJECT-TYPE
    SYNTAX      INTEGER {
                          eNone(1),
                          ePrintReport(2),
                          ePrintReportOnSend(3),
                          ePrintReportOnError(4),
                          ePrintReportOnSendError(5),
                          ePrintReportOnReceiveError(6)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Provides a host application with the ability to print a fax		
                transmission report. The supported enumerations are:    	
                    eNone - no transmission report printed    	
                    ePrintReport - transmission report always printed    	
                    ePrintReportOnSend - transmission report printed on send		
                        only    	
                    ePrintReportOnError - transmission report printed on error		
                        only    	
                    ePrintReportOnSendError - transmission report printed on		
                        send error only    	
                    ePrintReportOnReceiveError - transmission report printed on		
                        receive error only.   "
::= { settings-fax-proc-sub 22 }


fax-report-activity-log OBJECT-TYPE
    SYNTAX      INTEGER {
                          eNever(1),
                          eThreshold(2)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Specifies when a report of fax transactions is to be printed.		
                   	
                       eNever - to never print a transaction report.    	
                    eThreshold - to automatically print a transaction report		
                        every N transactions.    	
                       	
                    The POS for each product shall specify the value of N.   	
                       	
                    FAX-REPORT-TRANSMISSION also prints a transaction report,		
                        but for only a given fax, not a log of fax activities.		
                        May not be settable if the fax machine is not idle.   	
                       	
                    The log is cleared after each printing caused by this		
                        object.   "
::= { settings-fax-proc-sub 23 }


fax-dial-tone-detection OBJECT-TYPE
    SYNTAX      INTEGER {
                          eDisabled(1),
                          eEnabled(2)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Determines whether the fax machine waits for a dial tone before		
                dialing a fax number. eEnabled - causes the fax machine to wait		
                until a dial tone is recognized before attempting to dial a fax		
                number. eDisabled - causes the fax machine to dial without		
                waiting to recognize a dial tone."
::= { settings-fax-proc-sub 24 }


fax-alarm-volume OBJECT-TYPE
    SYNTAX      INTEGER(0..3)
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Range is 0..100, where 0 = quietest possible, and 100 = loudest		
                possible. A device shall divide this value into ranges		
                corresponding to the possible volumes and document these		
                settings and their meanings in the product POS.
                Additional information:
                For this LaserJet MFP the range is 0..3, where 0=off (silent), 
                1=soft, 2=medium, and 3=loud."
::= { settings-fax-proc-sub 25 }


fax-beep-volume OBJECT-TYPE
    SYNTAX      INTEGER(0..3)
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Range is 0..100, where 0 = quietest possible, and 100 = loudest		
                possible. A device shall divide this value into ranges		
                corresponding to the possible volumes and document these		
                settings and their meanings in the product POS.
                Additional information:
                For this LaserJet MFP the range is 0..3, where 0=off (silent), 
                1=soft, 2=medium, and 3=loud."
::= { settings-fax-proc-sub 26 }


fax-ring-volume OBJECT-TYPE
    SYNTAX      INTEGER(0..3)
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Range is 0..100, where 0 = quietest possible, and 100 = loudest		
                possible. A device shall divide this value into ranges		
                corresponding to the possible volumes and document these		
                settings and their meanings in the product POS.
                Additional information:
                For this LaserJet MFP the range is 0..3, where 0=off (silent), 
                1=soft, 2=medium, and 3=loud."
::= { settings-fax-proc-sub 27 }


fax-master-host OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Identifies the hostname of the master host to which the device		
                is connected."
::= { settings-fax-proc-sub 28 }


fax-thumbnail-enable OBJECT-TYPE
    SYNTAX      INTEGER {
                          eDisabled(1),
                          eEnabled(2)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Controls whether or not a thumbnail reprint of the first page		
                of a fax shall be included on the fax call report. When set to		
                eEnabled a thumbnail shall be included on the report. When set		
                to eDisabled there shall be not be a thumbnail on the fax call		
                report.
                Additional information:
                Controls whether or not a thumbnail reprint of the 
                first page of a fax shall be included on the
                fax call report.  When set to eEnabled a thumbnail shall
                be included on the report.  When set to eDisabled there
                shall be not be a thumbnail on the fax call report."
::= { settings-fax-proc-sub 29 }


fax-phone-pickup-enable OBJECT-TYPE
    SYNTAX      INTEGER {
                          eDisabled(1),
                          eEnabled(2)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "This object is included to handle the situation where a fax		
                machine and a telephone share the same phone line.    	
                    If a call picked up at the phone turns out to be a fax		
                        call, the user may initiate a fax receive via the fax		
                        machine front panel (with, say, a button press). When		
                        this object is set to eEnabled and a fax call is		
                        answered at the phone, the user has the option of		
                        initiating the fax receive in the usual way at the fax		
                        front panel or by entering a (product-specific) key		
                        sequence on the telephone keypad (e.g. '***'). The		
                        device POS must indicate what the key sequence is for a		
                        particular product.    	
                    When this object is set to eDisabled and a fax call is		
                        answered at the phone, the user may only initiate the		
                        fax receive by taking the product-specific action (such		
                        as a button press) at the fax machine front panel.    	
                    It is necessary to be able to turn this feature off (i.e.		
                        set it to eDisabled) because the key sequence of a		
                        particular fax device may interfere with other devices		
                        connected to the phone line (e.g. an answering		
                        machine).   
                Additional information:
                On this LaserJet MFP, the key sequence to initiate a fax from the
                phone keypad is '***'."
::= { settings-fax-proc-sub 30 }


fax-adf-scan-count OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "This object tracks the page count for the pages scanned for		
                faxing from the ADF. In order to write this object		
                SERVICE-PASSWORD must be set correctly.
                Additional information:
                This object tracks the page count for the pages scanned for faxing
                from the ADF. In order to write this object SERVICE-PASSWORD must be
                set correctly."
::= { settings-fax-proc-sub 31 }


fax-print-page-count OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "This object tracks the page count for the pages sent to the		
                print engine for fax jobs. In order to write this object		
                SERVICE-PASSWORD must be set correctly.
                Additional information:
                This object tracks the page count for the pages sent to the print
                engine for fax jobs. In order to write this object SERVICE-PASSWORD
                must be set correctly."
::= { settings-fax-proc-sub 32 }


fax-download-page-count OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "This object tracks the page count for the pages downloaded to		
                the peripheral for fax jobs. In order to write this object		
                SERVICE-PASSWORD must be set correctly.
                Additional information:
                This object tracks the page count for the pages downloaded to the
                peripheral for fax jobs. In order to write this object SERVICE-PASSWORD
                must be set correctly."
::= { settings-fax-proc-sub 33 }


fax-upload-page-count OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "This object tracks the page count for the pages uploaded from		
                the peripheral for fax jobs. In order to write this object		
                SERVICE-PASSWORD must be set correctly.
                Additional information:
                This object tracks the page count for the pages uploaded from the
                peripheral for fax jobs. In order to write this object SERVICE-PASSWORD
                must be set correctly."
::= { settings-fax-proc-sub 34 }


fax-flatbed-scan-count OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "This object tracks the page count for the pages scanned for		
                faxing from the flatbed. In order to write this object the		
                SERVICE-PASSWORD must be set.
                Additional information:
                This object tracks the page count for the pages scanned
                for faxing from the flatbed.  In order to write this
                object the SERVICE-PASSWORD must be set."
::= { settings-fax-proc-sub 36 }


default-fax-glass-size OBJECT-TYPE
    SYNTAX      INTEGER {
                          eUSLetter(2),
                          eUSLegal(3),
                          eISOandJISA4(26)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Indicates the default fax glass size.
                Additional information:
                Indicates the default fax glass size."
::= { settings-fax-proc-sub 37 }


fax-cold-reset-fax-glass-size OBJECT-TYPE
    SYNTAX      INTEGER {
                          eUSLetter(2),
                          eUSLegal(3),
                          eISOandJISA4(26)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or sets the fax glass size that is used as the		
                DEFAULT-FAX-GLASS-SIZE when a cold reset occurs.
                Additional information:
                Returns or sets the fax glass size that is used as the
                DEFAULT-FAX-GLASS-SIZE when a cold reset occurs."
::= { settings-fax-proc-sub 38 }


fax-upload OBJECT-TYPE
    SYNTAX      INTEGER {
                          eFaxUploadIdle(1),
                          eFaxUploadStart(2),
                          eFaxUploadActive(3),
                          eFaxUploadAborted(4),
                          eFaxUploadDone(5),
                          eFaxUploadNeeded(6)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Note: The enumeration values for this object where changed in a		
                non-backwards compatible manner in version 4.7. Handshake		
                mechanism between host and device to notify and coordinate the		
                transfer of fax image data received by the device fax modem.		
                This object serves both as an indicator of fax upload activity		
                as well as a trigger for the host to alter fax upload progress.		
                Handshake mechanism between host and device to initiate scan		
                operation and coordinate the transfer of scanned image data to		
                the host. This object serves both as an indicator of scan		
                upload activity as well as a trigger for the host to alter scan		
                upload progress.    	
                    eFaxUploadIdle - indicates no fax upload activity is is		
                        occurring. Device powers up in this state but will		
                        otherwise never transition to this state of its own		
                        accord. Host setting to eFaxUploadIdle while object is		
                        in eFaxUploadActive will cause download activity to be		
                        prematurely terminated. Host setting to this state		
                        resets the handshake mechanism to permit another fax		
                        upload activity to be initiated.    	
                    eFaxUploadStart - indicates the host requests to commence		
                        an upload session for a received fax. This state is		
                        host settable only from eFaxUploadIdle. Device will		
                        never transition to this state of its own accord.    	
                    eFaxUploadActive - indicates a fax upload is occurring.		
                        This state is not host settable. Device will transition		
                        to this state from eFaxUploadStart as a positive		
                        response for host to commence upload of fax data. The		
                        object FAXJOB-UPLOAD-ID now contains the job ID.    	
                    eFaxUploadAborted - indicates the fax upload activity has		
                        been prematurely terminated by the device due to some		
                        error. Object FAX-UPLOAD-ERROR contains the error		
                        reason for the premature session termination. This		
                        state is device settable from eFaxUploadStart,		
                        eFaxUploadActive or eFaxUploadNeeded. This state is not		
                        host settable.    	
                    eFaxUploadDone - indicates the fax upload activity has		
                        reached a successful termination in that the device has		
                        transmitted all the upload data to the host. This state		
                        is only settable by the device from eFaxUploadActive.		
                        This state is not host settable. Host should transition		
                        from this state to eFaxUploadIdle in order to reset the		
                        handshake mechanism for subsequent upload session.    	
                    eFaxUploadNeeded - indicates device has received fax modem		
                        data available for host upload. This state is not host		
                        settable. This state is device settable from		
                        eFaxUploadIdle. Host should respond by setting to		
                        eFaxUploadStart to initiate upload session. Should host		
                        fail to respond by the time fax reception is complete		
                        or device has exhausted local memory storage, device		
                        shall transition object from eFaxUploadNeeded to		
                        eFaxUploadAborted. The POS should state the recourse		
                        behavior associated with the received fax.   "
::= { status-fax-proc-sub 1 }


fax-min-rings-pickup OBJECT-TYPE
    SYNTAX      INTEGER(1..1)
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Indicates the minimum legal rings before pickup."
::= { status-fax-proc-sub 2 }


fax-max-rings-pickup OBJECT-TYPE
    SYNTAX      INTEGER(1..10)
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Indicates the maximum legal rings before pickup."
::= { status-fax-proc-sub 3 }


fax-max-redials OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Maximum number of allowed redials."
::= { status-fax-proc-sub 4 }


fax-additional-wait OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Number of additional seconds to wait before beginning a		
                FAX-DOWNLOAD."
::= { status-fax-proc-sub 5 }


fax-download-error OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Error status of the fax download session."
::= { status-fax-proc-sub 6 }


fax-upload-error OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Error status of the fax upload session."
::= { status-fax-proc-sub 7 }


fax-firmware-revision OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(8))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "This object identifies the fax firmware ROM revision code. The		
                format is device specific and shall be specified in the device		
                POS.
                Additional information:
                This object identifies the fax firmware ROM revision
                code.  For this LaserJet MFP, the format for this object is a date
                in the form YYYYMMDD."
::= { status-fax-proc-sub 8 }


fax-forwarding-phone-num OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Phone number digits of the remote fax station where arrived		
                faxes are to be forwarded."
::= { fax-forwarding 3 }


fax-resolution OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(1..64))
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "struct {    	
                    unsigned_32bit x_res; /* 1st four bytes; big endian */    	
                    unsigned_32bit y_res; /* 2nd four bytes; big endian */    	
                    }    	
                    Sets the send fax resolution. The x and y resolutions in		
                        this object are in fixed-point with 16 bits of		
                        fraction, and 16 bits of integer, and are in dots per		
                        inch. X is horizontal; Y is vertical. Examples of		
                        computing x_res and y_res: 300 dots/inch:round(300 *		
                        65536) = 19660800    	
                    16 dots/mm: round(16 *25.4 * 65536) = 26633830.    	
                If the device does not support the given combination, then		
                it'll select the nearest supported values in a device-dependent		
                manner (documented in the POS).
                Additional information:
                This LaserJet MFP supports 4 fax resolutions.  As far as the
                end-user is concerned these resolutions are:  standard,
                fine, superfine, and photo.  Photo is not really a
                resolution--see more below.  Standard is the default.
                Resolutions map as follows (values are given in dots per
                inch (dpi) horizontal X vertical (x X y)):  standard(203
                X 98), fine(203 X 196), superfine(300 X 300), and
                photo(300 X 300).  
                
                Supported resolutions in hex notation (dpi, x X y) are:
                standard(00cb0000 X 00620000), fine(00cb0000 X 00c4000),
                superfine(012C0000 X 012C0000), and photo(012C0000 X
                012C0000).  
                
                The device ignores attempts to set invalid resolutions.  
                
                Photo is not a resolution, but photo setting depends on
                whether half-toning is on or off.  In the case of this LaserJet MFP
                photo setting doesn't actually change the bits going out
                the modem -- still one bit per pixel so photo and
                superfine are the same.  
                
                NOTE:  The last 16 bits of the horizontal and vertical
                settings are ignored.  Only the first 16 bits of the
                horizontal and vertical resolution setting are used."
::= { settings-fax-send 1 }


fax-contrast OBJECT-TYPE
    SYNTAX      INTEGER(-127..127)
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Behaves as SCL's 'Set Scanner Contrast Level' command which is		
                used for setting the sending fax contrast level. Range is		
                0..100.
                Additional information:
                Behaves as COPIER-CONTRAST and SCANNER-CONTRAST.
                Contrast values can range from -127 to +127, for a total
                of 255 contrast values.  Within that range, this LaserJet MFP
                supports 11 values.  They are:  -5, -4, -3, -2,
                -1, 0, 1, 2, 3, 4, 5.  The default contrast level is 0
                (normal).  A positive value results in a larger
                difference, and a negative value results in a smaller
                difference.  
                
                This LaserJet MFP snaps unsupported values toward zero as follows:  
                <=-125 snaps to -5  
                >-125 and <=-100 snaps to -4  
                >-100 and <=-75 snaps to -3  
                >-75 and <=-50 snaps to -2  
                >-50 and <=-25 snaps to -1  
                >-25 and <25 snaps to 0  
                >=25 and <50 snaps to 1  
                >=50 and <75 snaps to 2
                >=75 and <100 snaps to 3  
                >=100 and <125 snaps to 4  
                >=125 snaps to 5"
::= { settings-fax-send 2 }


fax-pixel-data-type OBJECT-TYPE
    SYNTAX      INTEGER {
                          eBiLevelThesholded(1),
                          eBiLevelHalfToned(2)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Sets the scanning method used when sending a fax.		
                eBiLevelThesholded - One bit per pixel, using simple		
                thresholding of greyscale scan data. eBiLevelHalfToned - One		
                bit per pixel, using some kind of half-toning technique (such		
                as dithering or error-diffusion) to approximate greyscale scan		
                data."
::= { settings-fax-send 3 }


not-ready-fax-send OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Indicates if the sending fax sub-system in the device is not		
                ready. If there are no items in the collection (i.e. no bits		
                are set), then the sending fax sub-system is ready. If there is		
                an item present, then the item indicates what is causing the		
                sending fax sub-system to be not ready."
::= { status-fax-send 1 }


fax-allow-redials OBJECT-TYPE
    SYNTAX      INTEGER {
                          eFalse(1),
                          eTrue(2)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "When eTrue, the FAX machine can redial a phone number if the		
                prior call failed for some reason. When eFalse, such redialing		
                will not occur.
                Additional information:
                This object is not used for this LaserJet MFP products."
::= { transmit-fax 3 }


hrMemorySize OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
       DESCRIPTION "The amount of physical main memory contained by
              the host.
              Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                The unit of measure for this object is 1024
                bytes. The default value assumes the base printer with no 
                additional memory."
::= { hrStorage 2 }


hrStorageIndex OBJECT-TYPE
    SYNTAX      INTEGER(1..2147483647)
    ACCESS      read-only
    STATUS      mandatory
       DESCRIPTION "A unique value for each logical storage area
              contained by the host.
              Refer to RFC 1514, Host Resources MIB, for more details."
::= { hrStorageEntry 1 }


hrStorageType OBJECT-TYPE
    SYNTAX      OBJECT IDENTIFIER
    ACCESS      read-only
    STATUS      mandatory
       DESCRIPTION "The type of storage represented by this entry.
              Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                The object is constant for the product."
::= { hrStorageEntry 2 }


hrStorageDescr OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      mandatory
       DESCRIPTION "A description of the type and instance of the
              storage described by this entry.
              Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                This object is not localized.  For the product, this 
                object is constant."
::= { hrStorageEntry 3 }


hrStorageAllocationUnits OBJECT-TYPE
    SYNTAX      INTEGER(1..2147483647)
    ACCESS      read-only
    STATUS      mandatory
       DESCRIPTION "The size, in bytes, of the data objects allocated
               from this pool.  If this entry is monitoring
               sectors, blocks, buffers, or packets, for example,
               this number will commonly be greater than one.
               Otherwise this number will typically be one.
               Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                Unit is one byte.  For the product,
                this object is constant."
::= { hrStorageEntry 4 }


hrStorageSize OBJECT-TYPE
    SYNTAX      INTEGER(0..2147483647)
    ACCESS      read-only
    STATUS      mandatory
       DESCRIPTION "The size of the storage represented by this entry,
              in units of hrStorageAllocationUnits.
              Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                Total formatter RAM.  (The value of this object
                is hrMemorySize times the unit of measure for hrMemorySize.
                For this procduct this is 65536*1024 bytes.)"
::= { hrStorageEntry 5 }


hrStorageUsed OBJECT-TYPE
    SYNTAX      INTEGER(0..2147483647)
    ACCESS      read-only
    STATUS      mandatory
       DESCRIPTION "The amount of the storage represented by this
              entry that is allocated, in units of
              hrStorageAllocationUnits.
              Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                This object returns the amount of memory in use
                by the printer at the current time.  This object should not
                be used when creating a print job for the device because the
                amount of memory in use will likely be different when the
                printer processes the print job."
::= { hrStorageEntry 6 }


hrStorageAllocationFailures OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
       DESCRIPTION "The number of requests for storage represented by
              this entry that could not be honored due to not
              enough storage.  It should be noted that as this
              object has a SYNTAX of Counter, that it does not
              have a defined initial value.  However, it is
              recommended that this object be initialized to
              zero.
              Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                This object is set to zero at power on and when
                any reset is done via prtGeneralReset.
                This object is incremented whenever the printer is short on
                memory (codewise:  when PersMemoryCycle is called with a
                parameter of 2)."
::= { hrStorageEntry 7 }


hrDeviceIndex OBJECT-TYPE
    SYNTAX      INTEGER(1..2147483647)
    ACCESS      read-only
    STATUS      mandatory
       DESCRIPTION "A unique value for each device contained by the
              host.  The value for each device must remain
              constant at least from one re-initialization of the
              agent to the next re-initialization.
              Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                The entry in the Device Table which describes
                the printer."
::= { hrDeviceEntry 1 }


hrDeviceType OBJECT-TYPE
    SYNTAX      OBJECT IDENTIFIER
    ACCESS      read-only
    STATUS      mandatory
       DESCRIPTION "An indication of the type of device.
              If this value is `hrDeviceProcessor { hrDeviceTypes
              3 }' then an entry exists in the hrProcessorTable
              which corresponds to this device.
              If this value is `hrDeviceNetwork { hrDeviceTypes 4
              }', then an entry exists in the hrNetworkTable
              which corresponds to this device.
              If this value is `hrDevicePrinter { hrDeviceTypes 5
              }', then an entry exists in the hrPrinterTable
              which corresponds to this device.
              If this value is `hrDeviceDiskStorage {
              hrDeviceTypes 6 }', then an entry exists in the
              hrDiskStorageTable which corresponds to this
              device.
              Refer to RFC 1514, Host Resources MIB, for more details."
::= { hrDeviceEntry 2 }


hrDeviceDescr OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(0..64))
    ACCESS      read-only
    STATUS      mandatory
       DESCRIPTION "A textual description of this device, including
              the device's manufacturer and revision, and
              optionally, its serial number.
              Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                The serial number is not returned with this
                object.  This object is not localized."
::= { hrDeviceEntry 3 }


hrDeviceID OBJECT-TYPE
    SYNTAX      OBJECT IDENTIFIER
    ACCESS      read-only
    STATUS      mandatory
       DESCRIPTION "The product ID for this device.
              Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                The complete OID reported by this object is:
                .1.3.6.1.4.1.11.2.3.9.1.2.48.3"
::= { hrDeviceEntry 4 }


hrDeviceStatus OBJECT-TYPE
    SYNTAX      INTEGER {
                          eHrunning(2),
                          eHwarning(3),
                          eHdown(5)
		   }
    ACCESS      read-only
    STATUS      mandatory
       DESCRIPTION "The current operational state of the device
              described by this row of the table.  A value
              unknown(1) indicates that the current state of the
              device is unknown.  running(2) indicates that the
              device is up and running and that no unusual error
              conditions are known.  The warning(3) state
              indicates that agent has been informed of an
              unusual error condition by the operational software
              (e.g., a disk device driver) but that the device is
              still 'operational'.  An example would be high
              number of soft errors on a disk.  A value of
              testing(4), indicates that the device is not
              available for use because it is in the testing
              state.  The state of down(5) is used only when the
              agent has been informed that the device is not
              available for any use.
              Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                The printer's condition is mapped as follows:
                
                eHrunning -- Printer ready to print or is printing.  It may
                be in power save mode.
                
                eHwarning -- A condition exists that needs attention, but it
                is not currently preventing printing.  A non-critical alert
                is active.
                
                eHdown -- Printer is not printing because it is offline, or
                a critical alert is active.  Human interaction is needed to
                bring the printer to a ready state."
::= { hrDeviceEntry 5 }


hrDeviceErrors OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      mandatory
       DESCRIPTION "The number of errors detected on this device.  It
               should be noted that as this object has a SYNTAX
               of Counter, that it does not have a defined
               initial value.  However, it is recommended that
               this object be initialized to zero.
               Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                This is the number of critical alerts that have
                been entered into the alert table since the device was
                powered on.  The maximum value for this object is 2^32-1.  At
                power-on, this object will be set to zero."
::= { hrDeviceEntry 6 }


hrPrinterStatus OBJECT-TYPE
    SYNTAX      INTEGER {
                          eHother(1),
                          eHidle(3),
                          eHprinting(4),
                          eHwarmup(5)
		   }
    ACCESS      read-only
    STATUS      mandatory
       DESCRIPTION "The current status of this printer device.  When
               in the idle(1), printing(2), or warmup(3) state,
               the corresponding hrDeviceStatus should be
               running(2) or warning(3).  When in the unknown
               state, the corresponding hrDeviceStatus should be
               unknown(1).
               Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                The printer's condition is mapped as follows:
                
                eHother -- The printer is offline, or a critical alert is
                active.
                
                eHidle -- The printer is not performing any of the items 
                listed under eHprinting status.
                
                eHprinting -- A job is currently being processed or printed, 
                or a PJL job is being processed.
                
                eHwarmup -- If hrDeviceStatus is eHdown, the printer is
                currently offline but is resolving the condition that caused
                it to be offline. It will be online when it is ready to
                print.  If hrDeviceStatus is eHrunning, the printer was
                in power save mode and is now becoming ready to print.  (In
                the product, this status only occurs very
                briefly at boot time.  At no other time does the printer
                report 'eHwarmup' status.)"
::= { hrPrinterEntry 1 }


hrPrinterDetectedErrorState OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      mandatory
       DESCRIPTION "This object represents any error conditions
               detected by the printer.  The error conditions are
               encoded as bits in an octet string, with the
               following definitions:
                    Condition         Bit #    hrDeviceStatus
                    lowPaper          0        warning(3)
                    noPaper           1        down(5)
                    lowToner          2        warning(3)
                    noToner           3        down(5)
                    doorOpen          4        down(5)
                    jammed            5        down(5)
                    offline           6        down(5)
                    serviceRequested  7        warning(3)
               If multiple conditions are currently detected and
               the hrDeviceStatus would not otherwise be
               unknown(1) or testing(4), the hrDeviceStatus shall
               correspond to the worst state of those indicated,
               where down(5) is worse than warning(3) which is
               worse than running(2).
               Bits are numbered starting with the most
               significant bit of the first byte being bit 0, the
               least significant bit of the first byte being bit
               7, the most significant bit of the second byte
               being bit 8, and so on.  A one bit encodes that
               the condition was detected, while a zero bit
               encodes that the condition was not detected.
               This object is useful for alerting an operator to
               specific warning or error conditions that may
               occur, especially those requiring human
               intervention.
               Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                The product reports error 
                conditions as follows:
                
                noPaper - A tray is empty and must be filled for printing to
                continue.
                hrDeviceStatus = eHdown;
                hrPrinterStatus = eHother;
                A critical alert is active.
                
                coverOpen -- A cover or door is open.
                hrDeviceStatus = eHdown;
                hrPrinterStatus = eHother;
                A critical alert is active.
                
                jammed -- A jam condition is preventing printing.
                hrDeviceStatus = eHdown;
                hrPrinterStatus = eHother;
                A critical alert is active.
                
                offline -- Printer is offline and will not accept new print
                jobs until it is online.  This condition is rare in the
                and may indicate some other error.
                hrDeviceStatus = eHdown;
                hrPrinterStatus = eHother;
                A critical alert is active.
                
                serviceRequested -- Any status or error condition not listed
                above.  These fall into two categories:
                (1) If the condition prevents printing, the 'offline' bit
                is also set and status values are as for offline.  i.e.:
                hrDeviceStatus = eHdown;
                hrPrinterStatus = eHother;
                A critical alert is active.
                (2) If the condition does not prevent printing the status
                values are:
                hrDeviceStatus = eHwarning;
                hrPrinterStatus = eHidle or eHprinting;
                A non-critical alert is active.
                
                lowToner -- The product can report this condition.
                
                noToner -- The product can report this condition."
::= { hrPrinterEntry 2 }


npCRCTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF NpCRCEntry
    ACCESS      not-accessible
    STATUS      current
       DESCRIPTION ""
::= { npCard 15 }


npCRCEntry OBJECT-TYPE
    SYNTAX      NpCRCEntry
    ACCESS      not-accessible
    STATUS      current
       DESCRIPTION ""
::= { npCRCTable 1 }


npCRCIndex OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-only
    STATUS      current
       DESCRIPTION ""
::= { npCRCEntry 1 }


npCRCText OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      current
       DESCRIPTION ""
::= { npCRCEntry 2 }


npCRCChannel OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-only
    STATUS      current
       DESCRIPTION ""
::= { npCRCEntry 3 }


inetTrapDestinationNum OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "Total number of ACTIVE rows in the inetTrapDestination table."
::= { inetTrapDestination 1 }


inetTrapDestinationTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF InetTrapDestinationEntry
    ACCESS      not-accessible
    STATUS      current
       DESCRIPTION "List of inetTrap destinations to which the agent sends traps."
::= { inetTrapDestination 2 }


inetTrapDestinationEntry OBJECT-TYPE
    SYNTAX      InetTrapDestinationEntry
    ACCESS      not-accessible
    STATUS      current
       DESCRIPTION "Entries are inetAddress Specific sequence of trap destination parameters."
::= { inetTrapDestinationTable 1 }


inetTrapRowIndex OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "Row Index of the inetTrapDestination table"
::= { inetTrapDestinationEntry 1 }


inetTrapRowStatus OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Individual Row Status
			1 - Row is Active - Row is activated and ready.
			2 - Not-In-Service - Row is suspended.
			3 - Not Ready - Row is not activated and still needs some columnar values to move to ready state.
			4 - Create and Go - This is set when the client uses multivarbind request to configure the trap table.
			5 - Create and Wait - This is set when the client does sequential configuration of the trap table.
			6 - Destroy - This is set when the client wants to delete the row from the table.
			"
::= { inetTrapDestinationEntry 2 }


inetTrapAddressType OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Protocol family for trap.  Possible values:
			ipv4(1)		An IPv4 address as defined by the
						InetAddressIPv4 textual convention.

			ipv6(2)     An IPv6 address as defined by the
						InetAddressIPv6 textual convention.

			dns(16)		A DNS domain name as defined by the
						InetAddressDNS textual convention."
::= { inetTrapDestinationEntry 3 }


inetTrapAddress OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "IPv4/IPv6/FQDN address of trap destination node."
::= { inetTrapDestinationEntry 4 }


inetTrapPort OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Port number of the inetTrap Destination to which the trap is sent."
::= { inetTrapDestinationEntry 5 }


inetTrapCommunityName OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Trap community name specified in the trap packet."
::= { inetTrapDestinationEntry 6 }


inetTrapVersion OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Trap version, one of the following
			0 = snmpV1
			1 = snmpV2
			3 = Inform
			Default is  1 = snmpV2.
			This value remains persistent through a powercycle."
::= { inetTrapDestinationEntry 7 }


inetTrapStyle OBJECT-TYPE
    SYNTAX      INTEGER {selectable-pml-traps(1),
                          aps-and-general-or-nrdpe-traps(2),
		   both-of-the-above(3)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "This OID is read-write.
			If the user wants to receive only the PML traps, then trapStyle can be set to 1.
			If the user wants to receive only APS and General or NOT-READY-DESTINATION-PRINT-ENGINE traps, then trapStyle can be set to 2.
			If the user wants to receive the both kinds of above traps, then trapStyle can be set to 3."
::= { inetTrapDestinationEntry 8 }


inetTrapPMLOids OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "This OID is a read-write. This will have tokens of PML trappable OIDs.
			Each token (OID) will be separated by a semi-colon. If a trap destination entry is 
			registered for only APS and general/NRDPE traps, then the pmlTrapOids OID will be a NULL string."
::= { inetTrapDestinationEntry 9 }


inetTrapErrorValue OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "Gives the error value in case if the server is not able to send the traps
			to the configured trapDestination entry. It will be set to below defined error values 
			if there the agent finds any error while dispatching a trap.			

			10 - Invalid value for rowStatus. Should be 1, 2, 3 or 6.
			11 - Ivalid value for InetTrapAddressType. Should be 1, 2 or 16.
			12 - Invalid for IP Address or FQDN.
			13 - Ivalid value for inetTrapPort. Should be greater than 0 or less than 65536.
			14 - Invalid valur for inetTrapCommunityName.
			15 - Invalid value for inetTrapVersion. Should be 0, 1 or 3.
			16 - Invalid value for inetTrapStyle. Should be either 1, 2 or 3.
			17 - Unable to resgister SOME or ALL PML trappable OIDs.
			
			51 - InetTrapAddressType & InetTrapAddress does not macth.
			52 - It is a Duplicate entry.
			53 - Unable to move the row to ACTIVE state because of insufficient/invalid entries.
			
			80 - Unable to resolve name: no DNS server.
			81 - Unable to resolve name: no DNS records present for name.
			82 - Unable to resolve name: no dns records matching FQDN Resolution Value.
			"
::= { inetTrapDestinationEntry 10 }


inetTrapTest OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      write-only
    STATUS      current
       DESCRIPTION "Causes agent to send an snmp trap to hosts registered in the trap
			destination table.  Value specified will be used as the specific 
			trap id."
::= { inetTrapDestination 3 }


inetTrapFilterDelay OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "The purpose of the trap filter feature is to prevent multiple traps
			of the same specificTrapId to be sent within a short period of time.
			This object assigns the period of time within which a duplicate trap
			will be blocked.  This value is in 1/10 second intervals and the default
			value is set to 50 corresponding to 5 seconds.
			This value remains persistent through a powercycle."
::= { inetTrapDestination 4 }


inetTrapBaseTimeout OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Applicable only if trapVersion is set to Inform.
			Units are 1/10 second intervals.  Default is 2
			corresponding to 200 milliseconds.  This value corresponds
			to the time of the first retry following the initial inform
			request. Additional retries are sent at times corresponding to
			the retry number multiplied by the inetTrapBaseTimeout.
			This value remains persistent through a powercycle."
::= { inetTrapDestination 5 }


inetTrapRetryNum OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Applicable only if trapVersion is set to Inform.
			This is the maximum number of inform retries that will be sent to
			this destination.  Retries are sent if no inform reply is received
			within the timeout value.  The timeout value is calculated as
			described under inetTrapBaseTimeout.
			This value remains persistent through a powercycle."
::= { inetTrapDestination 6 }


inetTrapFQDNResolution OBJECT-TYPE
    SYNTAX      INTEGER {resolve-for-IPv4-address(1),
                          resolve-for-IPv6-address(2),
		   resolve-for-both(10)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "The purpose of this field is to configure various options for resolving FQDN.
			If configured as 1  - then FQDN names will be resolved for IPv4 addresses only
			If configured as 2  - then FQDN names will be resolved for IPv6 addresses only.
			If configured as 10 - then FQDN names will be resolved for both IPv4 and IPv6 addresses."
::= { inetTrapDestination 7 }


inetTrapFQDNMultipleAddressBehavior OBJECT-TYPE
    SYNTAX      INTEGER {send-to-first-resolved-address(1),
		   send-to-all-resolved-address(2)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "1 - Send traps to the first resolved address
			 2 - Send traps to all resolved address.
			 "
::= { inetTrapDestination 8 }


inetTrapUseDNSCache OBJECT-TYPE
    SYNTAX      INTEGER {enable(1),
		   disable(0)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Depending upon the value of this field resolution of FQDN will happen everytime when a trap is sent."
::= { inetTrapDestination 9 }


trapDestinationNum OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "The number of trap destinations."
::= { trapDest 1 }


trapDestinationTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF TrapDestinationEntry
    ACCESS      not-accessible
    STATUS      current
       DESCRIPTION "Protocol specific list of destinations
                  to which the agent sends traps."
::= { trapDest 2 }


trapDestinationEntry OBJECT-TYPE
    SYNTAX      TrapDestinationEntry
    ACCESS      not-accessible
    STATUS      current
       DESCRIPTION "Entries are a protocol specific sequence of trap
          destination parameters."
::= { trapDestinationTable 1 }


trapTest OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Causes agent to send an snmp trap to hosts registered in the trap
               destination table.  Value specified will be used as the specific 
trap id."
::= { trapDest 3 }


trapSource OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "Sets the agent internal source for traps.  Possibilities are as follows:
         0 = ALL_TRAPS_ON
         1 = ASYNC_PERIPHERAL_STATUS traps only
         2 = proprietary PML traps only
         3 = alert table traps only  

         This object was changed to read-only to accommodate the SNMPv3 
         Notifiaction tables requirement to recieve all traps.  SNMPv3 tags
         are used to filter SNMP Trap sources."
::= { trapDest 4 }


trapFilterDelay OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "The purpose of the trap filter feature is to prevent multiple traps
        of the same specificTrapId to be sent within a short period of time.
        This object assigns the period of time within which a duplicate trap
        will be blocked.  This value is in 1/10 second intervals and the default
        value is set to 50 corresponding to 5 seconds. This value remains 
persistent
        through a powercycle."
::= { trapDest 5 }


trapFQDNNum OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "Number of trapFQDNTable rows."
::= { trapDest 6 }


trapFQDNTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF TrapFQDNEntry
    ACCESS      not-accessible
    STATUS      current
       DESCRIPTION "The trap destination entries can be mapped to destination's FQDN name in this table."
::= { trapDest 7 }


trapFQDNEntry OBJECT-TYPE
    SYNTAX      TrapFQDNEntry
    ACCESS      not-accessible
    STATUS      current
       DESCRIPTION "An FQDN destination entry indexed by the destination's IP address."
::= { trapFQDNTable 1 }


trapIPAddress OBJECT-TYPE
    SYNTAX      IpAddress
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "The trap destination IP address."
::= { trapFQDNEntry 1 }


trapFQDN OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "The trap destination's FQDN. This will be resolved to IP address(es) at trap destination time."
::= { trapFQDNEntry 2 }


setCommunityName OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "This object controls access of snmp read-write requests.  Factory
        default configuration provides authentication of incoming packets 
        with community names: internal and public.  This object overrides the 
        factory default settings so that the factory default setttings no longer
        work. This object returns SET or NOT_SET."
::= { community 1 }


getCommunityName OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "This object controls access of snmp read requests.  Factory
        default configuration provides authentication of incoming packets
        with community names: internal and public.  This object provides
        access in addition to the factory default settings. If 
        set, then authentication will succeed with any of the following
        community names: internal, public, getCommunityName, or 
        setCommunityName. This object returns SET or NOT_SET."
::= { community 2 }


npSysStatusMessage OBJECT-TYPE
    SYNTAX      DisplayString
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "A status string reflecting the current state of the card
         and peripheral."
::= { npSys 2 }


npSysModelNumber OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "The HP model number of the device."
::= { npSys 10 }


npSysNetworkConnectors OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "This object describes the network connectors supported by the
	 device.  The value is a bit mask.  A set bit indicates the
         connector is supported.
         Bit      Value     Connector
          0       0x01      Ethernet, BNC
          1       0x02      Ethernet, AUI
          2       0x04      Ethernet, RJ-45
          3       0x08      TokenRing, DB-9
          4       0x10      TokenRing, RJ-45
          5       0x20      LocalTalk
          6       0x40      100VG, RJ-45
          7       0x80      100T, RJ-45"
::= { npSys 11 }


npSysCardServices1 OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "This object is a bitmap showing what services are available
         on the card.

         Bit  0 - IPX/SPX/NCP protocol stack
         Bit  1 - IP/TCP protocol stack
         Bit  2 - LLC/DLC protocol stack
         Bit  3 - Ethertalk protocol stack
         Bit  4 - IPv6 protocol stack
         Bit  5 - IPSec protocol stack
         Bits  6 - 11 Reserved                  
         Bit 12 - LPD print services
         Bit 13 - FTP print services
         Bit 14 - Port 9100 print services
         Bit 15 - IPP print services
         Bits 16 - 23 Reserved
         Bit 24 - Queue Server Bindery
         Bit 25 - Queue Server NDS
         Bit 26 - Remote Printer
         Bit 27 - SPX Direct Mode
         Bit 28 - DLC Print Services
         Bit 29 - EtherTalk Print Services
         Bits 30 - 31 Reserved"
::= { npSys 16 }


npSysCardServices2 OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "This object is a bitmap showing what services are available
         on the card.

         Bit  0 - XIP2
         Bit  1 - PML Get/Set
         Bit  2 - PML Traps
         Bit  3 - Scan to Web Browser
         Bit  4 - Scan to Email
         Bit  5 - MFP Scan Support
         Bits  6 - 11 Reserved
         Bit 12 - Telnet API
         Bit 13 - Web API
         Bit 14 - SNMP V2
         Bit 15 - SNMP Traps
         Bit 16 - Download
         Bit 17 - TFTP
         Bit 18 - RCFG
         Bit 19 - SLP
         Bit 20 - Syslog
         Bit 21 - DHCP
         Bit 22 - BOOTP
         Bit 23 - RARP
         Bit 24 - SNMP V3
         Bit 25 - SSL Functionality
         Bit 26 - Auto IP
         Bit 27 - SNMP V3 SHA-1 & AES-128 support.
         Bits 28 - 31 Reserved"
::= { npSys 17 }


npSysCardServices3 OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "This object is a bitmap showing what services are available
         on the card.

         Bit  0 - 100T                       
         Bit  1 - Token Ring 802.5           
         Bit  2 - 802.11b                    
         Bit  3 - 80211.a                    
         Bit  4 - Bluetooth                  
         Bits 5 - 11 Reserved                                      
         Bit  12 -  EIO. For embedded Jetdirect this bit will be 1.                        
         Bit  13 - LIO                        
         Bit  14 - USB                        
         Bit  15 - Firewire                   
         Bit  16 - TCP Download

         Bits 17 - 31 Reserved"
::= { npSys 22 }


npConnsIP OBJECT-TYPE
    SYNTAX      IpAddress
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "Remote IP address of the node currently connected to the card.
         Zero if no connection is active."
::= { npConns 11 }


npCfgSource OBJECT-TYPE
    SYNTAX      INTEGER {manual-one(1),
                          bootp-two(2),
                          manual-three(3),
                          bootp-four(4),
                          dhcp(5),
                          not-configured(6),
                          default-config(7),
                          rarp(8),
                          read-only(9),
		   auto-ip(10)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "This object indicates how the device obtained its IP configuration."
::= { npCfg 1 }


npCfgYiaddr OBJECT-TYPE
    SYNTAX      IpAddress
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "The IP address assigned to the card from the BOOTP reply
         yiaddr field."
::= { npCfg 2 }


npCfgSiaddr OBJECT-TYPE
    SYNTAX      IpAddress
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "The IP address of the TFTP server from the BOOTP reply
         siaddr field."
::= { npCfg 3 }


npCfgLogServer OBJECT-TYPE
    SYNTAX      IpAddress
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "The IP address of the Syslog Server. If set via BOOTP (Tag: 7 field,
         lg=<ipaddress> ) then SNMP set will fail. If not set via BOOTP then SNMP set
         will succeed. Value saved across warm boot power cycles. BOOTP will always
         overwrite SNMP set values."
::= { npCfg 5 }


npCfgSyslogFacility OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "This specifies the facility identifier used in syslog messages
         generated by the card."
::= { npCfg 6 }


npCfgAccessState OBJECT-TYPE
    SYNTAX      INTEGER {allowed(1),
		   not-allowed(2)}
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "An indication of whether or not the requesting host
         is allowed to connect to the card as dictated by the
         access list."
::= { npCfg 7 }


npCfgAccessListNum OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "The number of access list entries."
::= { npCfg 8 }


npCfgAccessListTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF NpCfgAccessListEntry
    ACCESS      not-accessible
    STATUS      current
       DESCRIPTION "List of access addresses and masks."
::= { npCfg 9 }


npCfgAccessListEntry OBJECT-TYPE
    SYNTAX      NpCfgAccessListEntry
    ACCESS      not-accessible
    STATUS      current
       DESCRIPTION "Each entry contains an access address and mask."
::= { npCfgAccessListTable 1 }


npCfgAccessListIndex OBJECT-TYPE
    SYNTAX      Integer32 (0..9)
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "Index to the configuration access list table."
::= { npCfgAccessListEntry 1 }


npCfgAccessListAddress OBJECT-TYPE
    SYNTAX      IpAddress
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "The Access List Address contains the list of hosts or network
         of hosts that are allowed to connect to the print server over ip.
         When setting this object npCfgAccessListAddrMask should also
         be set in the same varbind packet. NpCfgAccessListAddress
         should always preceed npCfgAccessListAddrMask in the set packet.
         If npCfgAccessListAddrMask is not set, the default value of
         255.255.255.255 will be assigned to npCfgAccessListAddrMask
         for that particular npCfgAccessListAddress entry. Duplicate host
         addresses are possible and, once set, it is not possible to change
         any particular row other than to clear the Access List Table.
         To clear the Access List Table set npCfgAccessListAddress to 0.0.0.0.
         This table has a maximum of 10 rows."
::= { npCfgAccessListEntry 2 }


npCfgAccessListAddrMask OBJECT-TYPE
    SYNTAX      IpAddress
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Address mask used to help determine whether or not a given
         IP address is allowed access to the print server.  An IP address
         is allowed access if (Addr & AddrMask) == (IP & AddrMask).
         A set of this object may only be done if npCfgAccessListAddress
         preceeds it in the same varbind packet."
::= { npCfgAccessListEntry 3 }


npCfgSubnetMask OBJECT-TYPE
    SYNTAX      IpAddress
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "The subnet mask associated with the IP address of this card."
::= { npCfg 12 }


npCfgDefaultGateway OBJECT-TYPE
    SYNTAX      IpAddress
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "This variable contains the IP address of the default router for this
         card."
::= { npCfg 13 }


npCfgDomainName OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "The print server domain name."
::= { npCfg 16 }


npCfgIPP OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Below are the different values accepted by this OID.
     
				0 - Disable IPP and IPP-S
				1 - Enable IPP and IPP-S
				2 - Enable IPP-S only
				3 - Enable IPP only
			"
::= { npCfg 18 }


npCfgWINSNameServerIdPri OBJECT-TYPE
    SYNTAX      IpAddress
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Primary name server for NetBIOS over TCP/IP."
::= { npCfg 22 }


npCfgPasswd1Verify OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Compares string value to passwd1 and returns OK if match, 
     GENERAL ERROR if doesn't match."
::= { npCfg 28 }


npCfgPasswd1 OBJECT-TYPE
    SYNTAX      DisplayString
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Password for root or administrator. Get request returns 
     either 'SET' or 'NOT_SET'."
::= { npCfg 29 }


npCfgBanner OBJECT-TYPE
    SYNTAX      Integer32 (0..1)
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Line Printer Daemon Protocol (LPD) banner page per I/O port.
       (0) = Disabled
       (1) = Enabled
     Enabled by default."
::= { npCfg 31 }


npCfgLinkType OBJECT-TYPE
    SYNTAX      INTEGER {autoNegotiate(1),
                          full10T(2),
                          half10T(3),
                          full100T(4),
                          half100T(5),
                          auto100T(6),
		   full1000T(7)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Network link speed and communication mode."
::= { npCfg 35 }


npCfgSnmpDefaultReadCmnty OBJECT-TYPE
    SYNTAX      Integer32 (0..1)
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Controls Default Read Community Name access.
       (0) = Disabled, i.e., default get community names FAIL to access target.
       (1) = Enabled,  i.e., default get community names SUCCEED to access target."
::= { npCfg 40 }


npCfgBonjourServiceName OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "The name by which all the Jetdirect services will be advertised by 
       Multicast Domain Name System (Bonjour). Must set a non empty string"
::= { npCfg 44 }


npCfgBonjourDomainName OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "The name used as the 'target name' in the DNS SRV records by 
     Multicast Domain Name System (Bonjour)."
::= { npCfg 46 }


npCfgIPv6DomainName OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "IPv6 Domain Name."
::= { npCfg 49 }


npCfgIPv6ConfigState OBJECT-TYPE
    SYNTAX      INTEGER {ipv6-going-down(0),
		   ipv6-is-up(1)}
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "IPv6 stack status event; IPv6 enabled/disabled."
::= { npCfg 50 }


npCfgIPv6DNSAddr1 OBJECT-TYPE
    SYNTAX      InetAddress
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "IPv6 DNS Address, priority 1."
::= { npCfg 56 }


npCfgIPv6DNSAddr2 OBJECT-TYPE
    SYNTAX      InetAddress
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "IPv6 DNS Address, priority 2."
::= { npCfg 57 }


npCfgIPConfigPrecedence OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Allows to set uniform rules for parameter overwrite by
			different configuration methods.   		
			0 - Manual    			  			
			1 - TFTP  			  			
			2 - DHCPv4/Bootp 			  			
			3 - DHCPv6     - only if ipv6 is supported		
			3/4 - Default  - 4 if ipv6 is supported otherwise 3			  			
			The set string should be 0:1:2:3:4 (or 0:1:2:3 when ipv6 is not supported) 
			or any colon separated combination of the 5 (or 4) integral values. The 
			string should contain all integral values atleast and atmost once."
::= { npCfg 59 }


npCfgPortConfig OBJECT-TYPE
    SYNTAX      INTEGER {half10T(10),
                          full10T(11),
                          half100T(12),
                          full100T(13),
		   full1000T(19)}
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "Network link speed and communication mode."
::= { npCfg 65 }


npCfgWiFiDirectChannelNumber OBJECT-TYPE
    SYNTAX      INTEGER(1..13)
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "The WiFi channel number used for Wireless/Wi-Fi Direct.
                Region               Allowed Channels
                -------------------                  ----------------
                US & Worldwide Safe   1 - 11
                Rest of the world          1 - 13

                If wireless station is enabled, this setting is ignored and the 
                channel used is determined by the AP to which the device is 
                associated to.
                Default channel is 6.     
            "
::= { npCfg 85 }


npCfgWiFiDirectSSIDPrefix OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "
             The prefix of the network name (SSID) used for Wireless/Wi-Fi 
             Direct. The value is 'HP-Print-XY-' where XY is the last two hex 
             characters from the wireless MAC address. On products supporting 
	     Wi-Fi Direct, the value is 'DIRECT-XY-HP '. The prefix is read-only.
             The value of this object is prefixed to the value of 
             npCfgWiFiDirectSSIDSuffix to form the complete SSID.
            "
::= { npCfg 86 }


npCfgWiFiDirectSSIDSuffix OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "
             The modifiable suffix of the network name (SSID) used for 
             Wireless/Wi-Fi Direct. The default is '<sub brand> <hp model>', 
             but it can be different depending on printer family.
             The value of this object is concatenated to the value of 
             npCfgWiFiDirectSSIDPrefix to form the complete SSID.
            "
::= { npCfg 87 }


npCfgWiFiDirectConnectionSecurity OBJECT-TYPE
    SYNTAX      INTEGER {automatic(0),
                          manual(1),
		   advanced(2)}
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "This is used to select the Wi-Fi Direct connection security method 
             which differentiates how the connection is done between a mobile 
             client and the printer. The following values are defined:
             Automatic  ( 0 )
             Manual     ( 1 )
             Advanced   ( 2 )
             
             Automatic - Printer will accept all Wi-Fi Direct initiated 
             connections without requiring the user to push a button on the 
             printer. The user may have to enter a PIN, provided by the printer, 
             if the mobile device requests PIN method.
             
             Manual - Wi-Fi Direct clients require printer interaction to 
             connect. The user has to push a button on the printer or enter a 
             PIN into the mobile device to connect depending on the method 
             requested by mobile device.
             
             Advanced  - This mode disables Wi-Fi Direct, switches to Wireless 
             Direct and allows configuration of advanced settings.
            "
::= { npCfg 88 }


npTcpTFTPFileName OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "The TFTP configuration file name."
::= { npTcp 9 }


npTcpTFTPServerId OBJECT-TYPE
    SYNTAX      IpAddress
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "TFTP server from which configuration 
         information is obtained."
::= { npTcp 10 }


npTcpSyslogMax OBJECT-TYPE
    SYNTAX      Integer32 (0..1000)
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Maximum number of syslog packets to be sent
         per minute. 0 = Disabled."
::= { npTcp 11 }


npTcpAppSyslogPriority OBJECT-TYPE
    SYNTAX      Integer32 (0..8)
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Priority below which the syslog messages will 
         not be sent. 
         Valid priority levels = 0 through 7.
         Disabled = 8."
::= { npTcp 12 }


npCtlReconfig OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Writing any value to this variable causes the card to
         reconfigure itself by doing the BOOTP/TFTP configuration
         activity."
::= { npCtl 8 }


npCtlProtocolSet OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "This is a 4 byte integer value.  The least significant bytes
         represent the protocols on the card.  A value of '1' indicates
         a protocol that is enabled.  A value of '0' indicates a
         protocol that is disabled.  
         The 32-bit protocol enable 'structure' is defined as:

    		bits 31-28:  Number of I/O channels/protocols present (NUM_CHAN)
    		bits 27-24:  Number of I/O channels which may operate concurrently
                    (NUM_OP_CHAN)
    		bits 23-16:  unused, reserved
    		bits 15-1:   Individual I/O channel/protocol enable bits,
                    0 == disable, 1 == enable
                    MIO_IOCHAN_NOVELL   bit   1
                    MIO_IOCHAN_LLC      bit   2
                    MIO_IOCHAN_TCP      bit   3
                    MIO_IOCHAN_ATALK    bit   4
                    MIO_IOCHAN_IPV6	bit   5
    		bit  0:      When NUM_OP_CHAN == 1, auto-protocol select enable bit,
                    0 == disable, 1 == enable  (APS_ON)"
::= { npCtl 9 }


npCtlSNMPEnableDisable OBJECT-TYPE
    SYNTAX      Integer32 (0..1)
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "0 = SNMP disabled 
        1 = SNMP enabled
        If SNMP is enabled, setting this object to 0 will 
        disable SNMP on the print server. Once disabled it is not
        possible to enable SNMP via SNMP. When enabled, 
        a get request will return 1. SNMP may be enabled 
        via a different user interface, such as telnet or 
        the print server Embedded Web Server."
::= { npCtl 14 }


npCtlTelnet OBJECT-TYPE
    SYNTAX      Integer32 (0..1)
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Configure Telnet service.
            (0) = Telnet disabled
            (1) = Telnet enabled"
::= { npCtl 19 }


npCtlFTP OBJECT-TYPE
    SYNTAX      Integer32 {
                          printDisable-downloadDisable(0),
                          printEnable-downloadEnable(1),
                          printEnable-downloadDisable(2),
                          printDisable-downloadEnable(3)
		   }
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Configure File Transfer Protocol (FTP) service.
            (0) = Both FTP Print and Download Disabled
            (1) = Both FTP Print and Download Enabled
            (2) = FTP Print Enabled and FTP Download Disabled
            (3) = FTP Print Disabled and FTP Download Enabled
            "
::= { npCtl 20 }


npCtlSLP OBJECT-TYPE
    SYNTAX      Integer32 (0..1)
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Configure Service Location Protocol (SLP) service.
            (0) = SLP disabled
            (1) = SLP enabled"
::= { npCtl 21 }


npCtlLPD OBJECT-TYPE
    SYNTAX      Integer32 (0..1)
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Configure Line Printer Daemon Protocol (LPD) service.
            (0) = LPD disabled
            (1) = LPD enabled"
::= { npCtl 22 }


npCtl9100 OBJECT-TYPE
    SYNTAX      Integer32 (0..1)
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Configure TCP port 9100 printing.
            (0) = port 9100 printing disabled
            (1) = port 9100 printing enabled"
::= { npCtl 24 }


npCtlSysLog OBJECT-TYPE
    SYNTAX      Integer32 (0..1)
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Configure Syslog service.
            (0) = Syslog service disabled
            (1) = Syslog service enabled
         Enabled by default."
::= { npCtl 26 }


npCtlSnmpVersionAccess OBJECT-TYPE
    SYNTAX      INTEGER {snmpV1RW-snmpV3RW(1),
                          snmpV1RO-snmpV3RW(2),
                          snmpV1NoAccess-snmpV3RW(3),
                          snmpV1RW-snmpV3NoAccess(4),
		   snmpV1RO-snmpV3NoAccess(5)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Manages an SNMP version's read and write access to the MIB."
::= { npCtl 27 }


npCtlSnmpV3InitAccount OBJECT-TYPE
    SYNTAX      INTEGER {destroy(0),
		   blockInitEncrypt(4)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Used to create initial SNMPv3 account.  The following rules apply:

         0 = clear init account, only if previously 0.
         4 = Block init account, only cold reset will clear or use Web User interface.

      Setting this object to blocked (4) will block an initial account
      creation until a cold reset."
::= { npCtl 28 }


npCtlBonjour OBJECT-TYPE
    SYNTAX      Integer32 (0..1)
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Configure Multicast Domain Name Service.
            (0) = Bonjour disabled
            (1) = Bonjour enabled"
::= { npCtl 29 }


npCtlNetworkConnectionMode OBJECT-TYPE
    SYNTAX      INTEGER {auto-cable-detect(1),
                          disable-radio(2),
		   disable-wired(3)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "This object controls the selection of the active network 
         interface used for communication. This is applicable to
         products supporting dual wired and wireless network interfaces"
::= { npCtl 32 }


npCtlIPSecurityPolicy OBJECT-TYPE
    SYNTAX      INTEGER {disable(0),
		   enable(1)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Disable IP Security (IPSec) or Firewall. Only disabling is allowed."
::= { npCtl 34 }


npCtlWSDiscovery OBJECT-TYPE
    SYNTAX      INTEGER {disable(0),
		   enable(1)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Web Services Discovery enable/disable."
::= { npCtl 36 }


npCtlWSPrint OBJECT-TYPE
    SYNTAX      INTEGER {disable(0),
		   enable(1)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Web Services Print enable/disable."
::= { npCtl 37 }


npCtlLLMNR OBJECT-TYPE
    SYNTAX      INTEGER {disable(0),
		   enable(1)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Link-Local Multicast Name Resolution( LLMNR ) enable/disable."
::= { npCtl 38 }


npCtlFpDot11WirelessState OBJECT-TYPE
    SYNTAX      INTEGER {disable(0),
		   enable(1)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Use for enabling and disabling Wireless Radio.
			The following values are defined:
			Disable		= 0
			Enable		= 1
			Default		= 1(Enabled)"
::= { npCtl 47 }


npCtlWiFiDirectSSIDBroadcast OBJECT-TYPE
    SYNTAX      INTEGER {not-allowed(0),
		   allowed(1)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "This is used to allow or hide broadcasting of the SSID (Network name).
             Allowed(Default) = 1
             Not Allowed      = 0
             Not Allowed (0) only takes effect when npCfgWiFiDirectConnectionSecurity is set to Advanced.
            "
::= { npCtl 57 }


npCtlWiFiDirectHidePassphrase OBJECT-TYPE
    SYNTAX      INTEGER {show(0),
		   hide(1)}
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "This controls display of the Wireless passphrase on configuration 
             reports/pages or on the control panel.
              Show = 0
              Hide = 1
              This object also controls whether or not the passphrase is included in the NFC record.  
              Hide (1) only takes effect when npCfgWiFiDirectConnectionSecurity is set to Advanced
            "
::= { npCtl 58 }


npCtlWiFiDirectHideSsid OBJECT-TYPE
    SYNTAX      INTEGER {show(0),
		   hide(1)}
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "This controls display of the network name (SSID) on configuration 
             reports/pages or on the control panel.
             Show = 0
             Hide = 1
             Hide (1) only takes effect when npCfgWifiDirectConnectionSecurity is set to Advanced
            "
::= { npCtl 59 }


npCtlAirPrintStatus OBJECT-TYPE
    SYNTAX      INTEGER {disable(0),
		   enable(1)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION " Use to Enabled/Disabled AirPrint functionality.
			Disable				= 0
			Enable(Default)		= 1
		    "
::= { npCtl 68 }


npCtlAllowRFC5746TLSSSLCompatibilityMode OBJECT-TYPE
    SYNTAX      INTEGER {disable(0),
		   enable(1)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "  Added to support RFC-5746.
			   This OID can be use to enable/disable legacy SSL renegotiation. 
			    Disable				= 0
			    Enable(Default)		= 1
		    "
::= { npCtl 70 }


npCtlWiFiDirectState OBJECT-TYPE
    SYNTAX      INTEGER {disabled(0),
		   enabled(1)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Configure 802.11 Wireless/Wi-Fi Direct  functionality
            0 = Wireless/Wi-Fi Direct is disabled
            1 = Wireless/Wi-Fi Direct is enabled
        "
::= { npCtl 74 }


npCtlAirScan OBJECT-TYPE
    SYNTAX      INTEGER {disable(0),
		   enable(1)}
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Used to Enable/Disable the AirScan service.
		Disable = 0
		Enable (Default) = 1"
::= { npCtl 79 }


npCtlAirFax OBJECT-TYPE
    SYNTAX      INTEGER {disable(0),
		   enable(1)}
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Used to Enable/Disable the AirFax service.
	     Disable = 0
	     Enable (Default) = 1"
::= { npCtl 80 }


npCtlGCPrint OBJECT-TYPE
    SYNTAX      INTEGER {disable(0),
                          enable(1),
		   remove(2)}
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Used to Enable/Disable/Remove(Hide) the GC Print service.
                          Disable = 0
                          Enable (Default) = 1
                          Remove = 2
                If disable is specified and the device is registered for Google
                Cloud Services, then the device will be unregistered.
                When remove is specified to an unregistered device, the 
                UI aspects of the feature are hidden from end user, so that the
                user will not be able to see the Google cloud Print Service feature.
                When remove is specified to a registered device, the device will 
                disable the feature and remove all user interfaces."
::= { npCtl 81 }


npPortNumPorts OBJECT-TYPE
    SYNTAX      Integer32 (0..255)
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "The number of peripheral interfaces supported by this device."
::= { npPort 1 }


npDHCPserver OBJECT-TYPE
    SYNTAX      IpAddress
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "IP address of DHCP server that provided this unit with an IP
         address via the DHCP protocol."
::= { npDhcp 2 }


npDhcpFQDNBehavior OBJECT-TYPE
    SYNTAX      INTEGER {present-JD-Behavior(0),
		   rFC4702-compliant-Behavior(1)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "This object defines the FQDN behavior in Jetdirect. Set this to
			 ( 0 ) - Present Jetdirect Behavior
			 ( 1 ) - RFC 4702 compliant behavior"
::= { npDhcp 4 }


npWebProxyServerId OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "IP address or hostname of web proxy server."
::= { npWeb 12 }


npWebProxyServerPort OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "IP port of web proxy server"
::= { npWeb 13 }


npWebProxyUserName OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Proxy web user identification"
::= { npWeb 14 }


npWebProxyUserPasswd OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Proxy web user password"
::= { npWeb 15 }


npWebCheckACLforHTTP OBJECT-TYPE
    SYNTAX      Integer32 (0..1)
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Configure checking of HTTP web connections against Access Control List.
      (0) = Disable ACL checking
      (1) = Enable ACL checking"
::= { npWeb 17 }


npSecurityDot1xServerAuthProtocols OBJECT-TYPE
    SYNTAX      INTEGER {eap-md5(1),
                          eap-tls(2),
                          leap(4),
                          peap(8),
		   ttls(16)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "
            HP print servers support secured network access via Extensible Authentication Protocol (EAP)
            on an IEEE 802.1X network. The IEEE 802.1X standard provides a port-based authentication protocol
            where a network port allows or blocks use, depending on client authentication results.
            
            When using an 802.1X connection, the print server supports EAP with an authentication server, 
            such as a remote authentication dial-in user service (RADIUS, RFC 2138) server.

            Brief description of few currently supported EAP/802.1X methods:
            1) LEAP (lightweight EAP) is a proprietary Cisco Systems protocol that uses passwords for 
            mutual authentication. It is used to authenticate access by a wireless client, typically a Cisco 
            Aironet base station.

            2) PEAP (Protected EAP) is a mutual authentication protocol that uses digital certificates 
            for network server authentication and passwords for client authentication. For additional 
            security, the authentication exchanges are encapsulated within transport layer security (TLS). 
            Dynamic encryption keys are used for secure communications. 
            
            3) EAP-TLS (RFC 2716) is a mutual authentication protocol based on X.509v3compliant digital 
            certificates for authentication of both the client and the network authentication server. 
            Dynamic encryption keys are used for secure communications.
                    
            The following bitwise values are defined for this OID:    
                   None(0),
                   EAP-MD5(1), 
                   EAP-TLS(2),
                   LEAP(4),
                   PEAP(8),
                   TTLS(16)

            Note: 
            1) Not all of the above protocols might be supported on the printer. Use the OID 
            npSecurityServicesSupported (1.3.6.1.4.1.11.2.4.3.20.27.0) to determine the supported protocols.
        "
::= { npSecurity 1 }


npSecurityDot1xUsername OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "
            Username required by EAP/802.1x Authentication methods.         
        "
::= { npSecurity 2 }


npSecurityDot1xAuthServerId OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "
         Server ID relates to the Common Name that is returned in the subject of the Authentication 
         Server Certificate and determines how print server should validate the authentication server.                                  
        
        Server ID can be configured with a partial string (right-most characters) unless the Require Exact Match feature 
        is enabled.
            Few examples:            
            1) Server id is blank: If the Authentication Servers certificate is trusted, accept all Common Names 
               returned in the Subject field of the Authentication Server certificate 
            2) Server id is configured and Require Exact Match is not enabled:  If the Authentication servers certificate
               is trusted, accept all Common Names returned in the Subject field of the Authentication Server certificate 
               that have the configured server id as a rightmost subset. 
            3) Server id is configured and Require Exact Match is enabled: If the Authentication Servers certificate
               is trusted, accept all Common Names with the exact name"
::= { npSecurity 3 }


npSecurityPublicKey OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "The public key of a public/private key pair to be
	  used by applications to set encrypted values."
::= { npSecurity 4 }


npSecurityDot11EncryptedDot11NetworkName OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      write-only
    STATUS      current
       DESCRIPTION "The encrypted network name (SSID).  Use the 
        npSecurityPublicKey to encrypt this value.
	  Setting this object will cause the card to reconfigure."
::= { npSecurity 5 }


npSecurityEncryptedDot1xPassword OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "
            Password required by EAP/802.1x Authentication methods 

            Use the npSecurityPublicKey (1.3.6.1.4.1.11.2.4.3.20.4.0) to encrypt this value using 
            RSA public key encryption before performing snmpset. 
            This is OID is logically write-only and a SnmpGet returns SET or NOT_SET. 
        "
::= { npSecurity 6 }


npSecurityDot11EncryptedWEPKeyTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF NpSecurityDot11EncryptedWEPKeyEntry
    ACCESS      not-accessible
    STATUS      current
       DESCRIPTION "Encrypted interface to the WEP Keys."
::= { npSecurity 7 }


npSecurityDot11EncryptedWEPKeyEntry OBJECT-TYPE
    SYNTAX      NpSecurityDot11EncryptedWEPKeyEntry
    ACCESS      not-accessible
    STATUS      current
       DESCRIPTION "Each row of the table gives a WEP Key"
::= { npSecurityDot11EncryptedWEPKeyTable 1 }


npSecurityDot11EncryptedWEPKey OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      write-only
    STATUS      current
       DESCRIPTION "The encrypted WEP Key value.  Use 
        the npSecurityDot11PublicKey to encrypt this value. 
        Setting this object will cause the card to reconfigure."
::= { npSecurityDot11EncryptedWEPKeyEntry 2 }


npSecurityDot11SignalStrength OBJECT-TYPE
    SYNTAX      INTEGER {level-1-TBD(1),
                          level-2-TBD(2),
                          level-3-TBD(3),
                          level-4-TBD(4),
		   level-5-TBD(5)}
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "A weighted average over time of the signal strength
        between the access point and the print server in infrastructure
        mode. Not applicable when in ad hoc mode."
::= { npSecurity 8 }


npSecurityDot11SSIDTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF NpSecurityDot11SSIDEntry
    ACCESS      not-accessible
    STATUS      current
       DESCRIPTION "List of discovered SSIDs."
::= { npSecurity 9 }


npSecurityDot11SSIDEntry OBJECT-TYPE
    SYNTAX      NpSecurityDot11SSIDEntry
    ACCESS      not-accessible
    STATUS      current
       DESCRIPTION "Each row of the table gives a discovered SSID value."
::= { npSecurityDot11SSIDTable 1 }


npSecurityDot11SSID OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "A discovered SSID value."
::= { npSecurityDot11SSIDEntry 2 }


npSecurityDot11SSIDTableNumEntries OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "Displays the number of discovered SSIDs in
         the SSID Table."
::= { npSecurity 10 }


npSecurityDot11SSLCertLoaded OBJECT-TYPE
    SYNTAX      INTEGER {true(1),
		   false(2)}
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "Indicates if SSL certificate has been loaded."
::= { npSecurity 11 }


npSecurityDot11TLSCertLoaded OBJECT-TYPE
    SYNTAX      INTEGER {true(1),
		   false(2)}
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "Indicates if TLS Trusted CA certificate has been loaded."
::= { npSecurity 12 }


npSecuritySnmpV3EncryptedUserName OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      write-only
    STATUS      current
       DESCRIPTION "The encrypted SNMPv3 User Name.  
        Use the npSecurityPublicKey to encrypt this value.
        When setting this object, all three user account objects (npSecuritySnmpV3EncryptedUserName, 
        npSecuritySnmpV3AuthKeyPassPhrase, and npSecuritySnmpV3PrivKeyPassPhrase) should also be set in
        the same multi-varbind request.
        Implementations may accept the objects in separate SNMP requests, or they may return a inconsistentValue (12)
        failure to indicate that other objects are required.
        If setting the objects individually is allowed, the User Account will not be installed until after all three
        objects have been set.
        This OID can only be SET if the inital SNMP V3 account is not created 
        (i.e. the value of npCtlSnmpV3InitAccount is 0)
        If the user account is created successfully, it gets added as an entry in the usmUserTable (i.e. 1.3.6.1.6.3.15.1.2.2)
        "
::= { npSecurity 13 }


npSecuritySnmpV3AuthKeyPassPhrase OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      write-only
    STATUS      current
       DESCRIPTION "The encrypted SNMPv3 Authentication passphrase or key .  
        Use the npSecurityPublicKey to encrypt this value. 
        When setting this object, all three user account objects (npSecuritySnmpV3EncryptedUserName, 
        npSecuritySnmpV3AuthKeyPassPhrase, and npSecuritySnmpV3PrivKeyPassPhrase) should also be set in
        the same multi-varbind request.
        Implementations may accept the objects in separate SNMP requests, or they may return a inconsistentValue (12)
        failure to indicate that other objects are required.
        If setting the objects individually is allowed, the User Account will not be installed until after all three
        objects have been set.
        The other OID's related to SNMPv3 authentication are 
        npSecuritySnmpV3AuthAlgorithm and npSecuritySnmpV3PassPhrase, please ensure that they are set appropriately.
        This OID can only be SET if the inital SNMP V3 account is not created 
        (i.e. the value of npCtlSnmpV3InitAccount is 0)
        The values of npSecuritySnmpV3AuthAlgorithm and npSecuritySnmpV3PassPhrase must be set appropriately
        before setting the value of this OID.
        "
::= { npSecurity 14 }


npSecuritySnmpV3PrivKeyPassPhrase OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      write-only
    STATUS      current
       DESCRIPTION "The encrypted SNMPv3 Privacy passphrase or key.
        Use the npSecurityPublicKey to encrypt this value. 
        When setting this object, all three user account objects (npSecuritySnmpV3EncryptedUserName, 
        npSecuritySnmpV3AuthKeyPassPhrase, and npSecuritySnmpV3PrivKeyPassPhrase) should also be set in
        the same multi-varbind request.
        Implementations may accept the objects in separate SNMP requests, or they may return a inconsistentValue (12)
        failure to indicate that other objects are required.
        If setting the objects individually is allowed, the User Account will not be installed until after all three
        objects have been set.
        The other OID's related to SNMPv3 encryption are 
        npSecuritySnmpV3PrivAlgorithm and npSecuritySnmpV3PassPhrase, please ensure that they are set appropriately.
        This OID can only be SET if the inital SNMP V3 account is not created 
        (i.e. the value of npCtlSnmpV3InitAccount is 0)
        The values of npSecuritySnmpV3PrivAlgorithm and npSecuritySnmpV3PassPhrase must be set appropriately
        before setting the value of this OID.
        "
::= { npSecurity 15 }


npSecurityDot11BSSID OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "The BSSID value (hardware address of the access point)."
::= { npSecurity 16 }


npSecurityDot1xTunnelAuthBits OBJECT-TYPE
    SYNTAX      INTEGER {eap-md5(1),
                          eap-mschap(2),
                          eap-mschapv2(4),
                          mschap(8),
                          mschapv2(16),
		   eap-gtc(32)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "The Dot1x Tunnel Authentication Bits.  Bitwise field 
         with the followings bits:

         Default  All bits cleared
         EAP MD5          1
         EAP MSCHAP       2
         EAP MSCHAPv2     4
         MSCHAP           8
         MSCHAPv2         16
         EAP GTC          32"
::= { npSecurity 17 }


npSecurityDot1xIdentityCleartext OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "The Dot1x Identity in cleartext."
::= { npSecurity 18 }


npSecurityDot1xExactMatchServerId OBJECT-TYPE
    SYNTAX      TruthValue
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "
            This OID allows us to configure the Require Exact Match feature which indicates 
            how common name from a successfully authenticated server is considered.

            Few examples:            
            1) Server id is blank: If the Authentication Servers certificate is trusted, accept all Common Names 
               returned in the Subject field of the Authentication Server certificate 
            2) Server id is configured and Require Exact Match is not enabled:  If the Authentication servers certificate
               is trusted, accept all Common Names returned in the Subject field of the Authentication Server certificate 
               that have the configured server id as a rightmost subset. 
            3) Server id is configured and Require Exact Match is enabled: If the Authentication Servers certificate
               is trusted, accept all Common Names with the exact name
        "
::= { npSecurity 19 }


npSecurityDot1xEncryptionStrength OBJECT-TYPE
    SYNTAX      INTEGER {low(1),
                          medium(2),
		   high(3)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "
            Encryption strength determines the minimum strength of the SSL tunnel by determining what ciphers are advertised by the 
            print server in the TLS Client Hello packet. Low, Medium, High encryption strengths corresponds to
            various ciphers and key sizes.
            
            If FIPS is enabled, default encryption strength set is HIGH. 
        "
::= { npSecurity 20 }


npSecurityCertBuff OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "A 512 byte buffer of the print server certificate as indexed by 
        npSecurityCertBuffIndex."
::= { npSecurity 21 }


npSecurityCertBuffIndex OBJECT-TYPE
    SYNTAX      INTEGER {block1(1),
                          block2(2),
                          block3(3),
                          block4(4),
                          block5(5),
		   block6(6)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Indicates the index of the 512 byte block of the print server 
        certificate to load into npSecurityCertBuff."
::= { npSecurity 22 }


npSecuritySslRedirection OBJECT-TYPE
    SYNTAX      INTEGER {redirectionEnabled(1),
		   redirectionDisabled(2)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Setting this object causes the SSL redirection connection 
         to be enabled or disabled."
::= { npSecurity 23 }


npSecurityReset OBJECT-TYPE
    SYNTAX      INTEGER {set(0),
		   reset(1)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Setting this object causes security object to reset bact to the defaults."
::= { npSecurity 24 }


npSecurityWebSpiEnable OBJECT-TYPE
    SYNTAX      TruthValue
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "This object enables/disables the Embedded Web Simple Printer Install feature."
::= { npSecurity 25 }


npSecurityDot11WEPStrength OBJECT-TYPE
    SYNTAX      INTEGER {not-set(1),
                          strenth-40-bit(2),
		   strenth-104-bit(3)}
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "Indicates the encryption strength of the WEP keys."
::= { npSecurity 26 }


npSecurityServicesSupported OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "
            BITWISE indication of the security services this device supports.
            The following bits are defined: 
            
            MD5                               (0)
            TLS                               (1)
            TTLS                              (2)
            LEAP                              (3)
            PEAP                              (4)
            Reserved                          (5 - 15) 
            WEP                               (16)
            WPA                               (17)
            AES                               (18) 
            WPA2                              (19)
            AUTO_FOR_WEP_SUPPORTED          (20)
            AUTO_FOR_WPA_SUPPORTED          (21)
            AUTO_FOR_ENCRYPTION_SUPPORTED   (22)        
            Reserved  (23 - 31)
        "
::= { npSecurity 27 }


npSecurityDot11Encryption OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "802.11 encryption method currently enabled.  
        The following values are defined:
        
       	NONE       (0x00)
       	SSN/WEP    (0x01)
       	TKIP       (0x02)
	    AES        (0x03)
	    AUTO       (0x04)
        Reserved  (5 - 31)
        
        It is advised not to use dot11PrivacyInvoked OID anymore, instead use npSecurityDot11Encryption.
        Since Jetdirect updates the same variable when the set happens through any of the two OIDs and 
        npSecurityDot11Encryption is more versatile, it is recommended to use this OID.
        "
::= { npSecurity 28 }


npSecurityDot11MulticastCipher OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "BITWISE indication of the multicast cipher method currently enabled.
         At minimum, one bit must be set.  
         The following bits are defined:
       	
	      WEP       (0)
	      WPA       (1)
         Reserved  (2 - 31)"
::= { npSecurity 29 }


npSecurityDot11BeaconTableNumEntries OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "Displays the number of discovered SSIDs in the DOT11 Beacon Table."
::= { npSecurity 34 }


npSecurityDot11OpenSSIDEnabled OBJECT-TYPE
    SYNTAX      TruthValue
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "Indicates if the Open SSID is enabled (Spirit-only)."
::= { npSecurity 35 }


npSecurityDot11EncryptedWPAConfigPSKPassPhrase OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      write-only
    STATUS      current
       DESCRIPTION "The encrypted WPA Config PSK PassPhrase.  Use the 
          npSecurityPublicKey to encrypt this value"
::= { npSecurity 36 }


npSecurityDot11DataRate OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "Current wireless network data rate"
::= { npSecurity 37 }


npSecurityDot11ScanComplete OBJECT-TYPE
    SYNTAX      INTEGER {true(1),
		   false(2)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Used to control scan for SSIDs in the wireless network.
         Set to false to initiate a scan. A value of true indicates
         the completion of the scan"
::= { npSecurity 38 }


npSecurityDot11RoamThreshold OBJECT-TYPE
    SYNTAX      INTEGER {no-signal(1),
                          very-weak-signal(2),
		   weak-signal(3)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Used to control roaming by the wireless radio. The radio on
         the print server will roam or try to find an access point with
         a stronger signal once the signal strength from the associated
         access point reaches the specified roam threshold level."
::= { npSecurity 39 }


npSecuritySslEncryptionStrength OBJECT-TYPE
    SYNTAX      INTEGER {low(1),
                          medium(2),
		   high(3)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "The SSL Encryption Strength.
			
			Setting to Low, Medium or High decides the set of Cipher Suites that
			would be supported by the device."
::= { npSecurity 40 }


npSecurityDot11InstantVerification OBJECT-TYPE
    SYNTAX      INTEGER {disable(0),
		   enable(1)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Enable and disable wireless instant verification. 			         
			(0) = Disable 			         
			(1) = Enable"
::= { npSecurity 41 }


npSecurityDot11DynamicEncryption OBJECT-TYPE
    SYNTAX      INTEGER {nONE(0),
                          bASIC(1),
                          wPA(2),
                          wPA2(3),
		   aUTO(4)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "WPA mode. 			         
			(0x00) = NONE 			         
			(0x01) = BASIC
			(0x02) = WPA
			(0x03) = WPA2
			(0x04) = AUTO"
::= { npSecurity 42 }


npSecurityDot11LinkAuthentication OBJECT-TYPE
    SYNTAX      INTEGER {open(1),
                          shared-key(2),
                          leap(128),
		   auto(143)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "DOT11 Link Authentication modes. 			         
			(1) = OPEN 			         
			(2) = SHARED-KEY
			(128) = LEAP
			(143) = AUTO
			
			We can set the Link Authentication using the object dot11AuthenticationAlgorithmsEnable ( OID: 1.2.840.10036.1.2.1.3.x )
			Since the dot11AuthenticationAlgorithsmEnable object does not supports setting of AUTO option, we provide this object.
			
			Through this OID you can set to any one of the above options.
			Whereas using the dot11AuthenticationAlgorithmsEnable object we can set either OPEN OR SHARED mode only."
::= { npSecurity 43 }


npSecuritySnmpV3AuthAlgorithm OBJECT-TYPE
    SYNTAX      INTEGER {md5(2),
		   sha-1(3)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Indicates the Authentication Algorithm used.
			It can have the value MD5 or SHA-1.
			This key will have a default value set to MD5.
			The following values are defined:
			MD5    2 (Default)
			SHA-1  3
			This OID can only be SET if the inital SNMP V3 account is not created 
			(i.e. the value of npCtlSnmpV3InitAccount is 0)
			"
::= { npSecurity 44 }


npSecuritySnmpV3PrivAlgorithm OBJECT-TYPE
    SYNTAX      INTEGER {des(2),
		   aes-128(3)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "Indicates the Privacy Algorithm used.
			It can have the value DES or AES-128.
			This key will have a default value set to DES.
			The following values are defined:
			DES       2 (Default)
			AES-128   3
			This OID can only be SET if the inital SNMP V3 account is not created 
			(i.e. the value of npCtlSnmpV3InitAccount is 0)
			"
::= { npSecurity 45 }


npSecurityWirelessDirectEncryptionMethod OBJECT-TYPE
    SYNTAX      INTEGER {noSecurity(1),
		   wpa(2)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "This is used to select the encryption protocol in Wireless Direct Mode.  
      			The following values are defined:
		           No Security     ( 1 )
		           WPA             ( 2 )
	    	"
::= { npSecurity 51 }


npSecurityWirelessDirectEncryptedPassPhrase OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      write-only
    STATUS      current
       DESCRIPTION "
             The WPA2 Passphrase or pre-shared key for secure Wireless Direct. 
             The values allowed are 8 to 63 printable ASCII characters for passphrase 
             or a 64 character hex value for pre-shared key.
             
             Use npSecurityPublicKey to encrypt this value.
            "
::= { npSecurity 55 }


npSecurityDot1xFailSafe OBJECT-TYPE
    SYNTAX      INTEGER {enable(1),
		   disable(0)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "After configuring 802.1x on the printer and switching it over to a secured network, if authentication is 
         successful printer retains connectivity and if it fails it loses connectivity. 
         In case of authentication failure, it does not acquire connectivity even when switched over to an unsecured network.
         802.1x failsafe is a feature which allows printer to retain connectivity in a unsecured network even if authentication fails. 
         Setting this OID to 1 enables this feature and setting to 0 disables this feature.
         
			Connect anyway (802.1x Fail-Safe)           ( 1 )
			Block network  (secure failure)             ( 0 )  
         "
::= { npSecurity 57 }


npSecurityIppAuthentication OBJECT-TYPE
    SYNTAX      INTEGER {disable(0),
		   enable(1)}
    ACCESS      read-write
    STATUS      current
       DESCRIPTION " 
         IPP Authentication is a feature which provides 'HTTP Basic Authentication' 
         for IPP Print-Jobs. 

         Use this OID to Enable/Disable IPP Authentication.
         
         0 - Disable IPP Authentication
         1 - Enable IPP Authentication
         
         npSecurityIppAuthentication(1.3.6.1.4.1.11.2.4.3.20.61.0) is dependent on npSecurityIppAuthUsername(1.3.6.1.4.1.11.2.4.3.20.62.0) 
	 and npSecurityIppEncryptedAuthPassword(1.3.6.1.4.1.11.2.4.3.20.63.0).
         To enable npSecurityIppAuthentication, npSecurityIppAuthUsername and npSecurityIppEncryptedAuthPassword have to be
         first configured with valid values.
         Once enabled, npSecurityIppAuthentication can independently be disabled. npSecurityIppAuthUsername and
         npSecurityIppEncryptedAuthPassword will continue to retain their values.
                  
         Errors returned: BAD VALUE(v1) or WRONG VALUE(v2/v3) will be returned when the OID is set with invalid value.
                          GENERIC ERROR will be returned if the interdependency validation between the above three OIDs fails.
         "
::= { npSecurity 61 }


npSecurityIppAuthUsername OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "
         IPP Authentication is a feature which provides
         'HTTP Basic Authentication' for IPP Print-Jobs. 

         Use this OID to configure the IPP Authentication Username.
         Strings of length 1 to 31 and having any printable alphanumeric
         characters except ()<>@,;:\/[]?={} can be set.
         Setting with an empty octet string is equivalent to resetting the Username to NULL.
         
         npSecurityIppAuthUsername(1.3.6.1.4.1.11.2.4.3.20.62.0) and npSecurityIppEncryptedAuthPassword(1.3.6.1.4.1.11.2.4.3.20.63.0)
         have to be set in the same varbind. Use npSecurityIppAuthentication(1.3.6.1.4.1.11.2.4.3.20.61.0) to enable the feature once
         the username and password are configured.
         
         Errors returned: BAD VALUE(v1) or WRONG VALUE(v2/v3) will be returned when the OID is set with invalid value.
                          GENERIC ERROR will be returned if the interdependency validation between the above three OIDs fails.
        "
::= { npSecurity 62 }


npSecurityIppEncryptedAuthPassword OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "
         IPP Authentication is a feature which provides
         'HTTP Basic Authentication' for IPP Print-Jobs. 
         
         Use this OID to configure the IPP Authentication Password.
         Strings of length 8 to 31 and having any printable alphanumeric
         characters except ()<>@,;:\/[]?={} can be set.
         Setting with an empty octet string is equivalent to resetting the Password to NULL.
         
         npSecurityIppAuthUsername(1.3.6.1.4.1.11.2.4.3.20.62.0) and npSecurityIppEncryptedAuthPassword(1.3.6.1.4.1.11.2.4.3.20.63.0)
         have to be set in the same varbind. Use npSecurityIppAuthentication(1.3.6.1.4.1.11.2.4.3.20.61.0) to enable the feature once
         the username and password are configured.
         
         Querying the OID will return 'SET' if the password is set and will return 'NOT_SET' if the password has not been configured.                                 

		Errors returned: BAD VALUE(v1) or WRONG VALUE(v2/v3) will be returned when the OID is set with invalid value.
                         GENERIC ERROR will be returned if the interdependency validation between the above three OIDs fails.
                                         
         NOTE: Use the npSecurityPublicKey(1.3.6.1.4.1.11.2.4.3.20.4.0) to encrypt the value before setting.
         "
::= { npSecurity 63 }


gdStatusBytes OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "The number of valid bytes in the gdStatusEntry
         array."
::= { generalDeviceStatus 1 }


gdStatusDisplay OBJECT-TYPE
    SYNTAX      DisplayString
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "The string diplayed on the peripheral front panel.
         For some peripherals, such as the HP LaserJet IIISi printer
         or HP DesignJet plotter, this is always a zero length string."
::= { generalDeviceStatus 3 }


gdStatusId OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "A formatted string of NVT ASCII 
         charactersdescribing this peripheral."
::= { generalDeviceStatus 7 }


gdStatusJobTimeout OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-write
    STATUS      obsolete
::= { generalDeviceStatus 10 }


gdPasswords OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "This object is used as a 256 byte NVRAM area for JetAdmin.  It
         is completely managed by JetAdmin.  Initially it is initialized
         to all zeros.  A coldboot will re-initialize to all zeros."
::= { generalDeviceStatus 13 }


pmlTrapEnable OBJECT-TYPE
    SYNTAX      OBJECT IDENTIFIER
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "This OID is used to enable individual peripheral trappable objects through the print server."
::= { netPMLtrap 1 }


pmlTrapDisable OBJECT-TYPE
    SYNTAX      OBJECT IDENTIFIER
    ACCESS      read-write
    STATUS      current
       DESCRIPTION "This OID is used to disable individual peripheral trappable objects through the print server."
::= { netPMLtrap 2 }


npNpiPaeClass OBJECT-TYPE
    SYNTAX      INTEGER {printer(1),
                          plotter(2),
		   xStation(3)}
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "The class assigned to the peripheral onto which
         this card is plugged."
::= { npNpiPeripheralAttributeEntry 2 }


npNpiPaeIdentification OBJECT-TYPE
    SYNTAX      INTEGER {laserjet-IIISI(1),
		   laserjet-4SI(5)}
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "The Identification number of the peripheral.  These values are
         defined in the MIO spec.  DesignJet, PaintJet XL300, and 
         DesignJet/600 peripherals will identify themselves as 
         LaserJet-IIIsi."
::= { npNpiPeripheralAttributeEntry 3 }


npNpiCaeClass OBJECT-TYPE
    SYNTAX      INTEGER {rs-232(1),
                          centronics(2),
                          csma-cd-network(3),
                          token-ring-network(4),
                          scsi(5),
                          hpib(6),
                          localtalk(7),
                          hpna(8),
                          usb(9),
                          firewire(10),
                          bluetooth(11),
		   ieee802-11b(12)}
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "The class of this network peripheral card."
::= { npNpiCardAttributeEntry 2 }


gdStatusLineState OBJECT-TYPE
    SYNTAX      Integer32 (0..255)
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "This describes the line state of the peripheral.
         When non-zero, the peripheral is off-line.  When
         zero the peripheral is on-line."
::= { gdStatusEntry 1 }


gdStatusPaperState OBJECT-TYPE
    SYNTAX      Integer32 (0..255)
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "This describes the state of the paper on the peripheral.
         When non-zero, the peripheral has a paper problem. When
         zero, the peripheral does not have a paper problem."
::= { gdStatusEntry 2 }


gdStatusInterventionState OBJECT-TYPE
    SYNTAX      Integer32 (0..255)
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "This describes the intervention state of the
         peripheral.  When non-zero, the peripheral requires
         human intervention to continue working.  When
         zero, it requires no assistance."
::= { gdStatusEntry 3 }


gdStatusPeripheralError OBJECT-TYPE
    SYNTAX      Integer32 (0..255)
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "This is the error code from the peripheral."
::= { gdStatusEntry 6 }


gdStatusPaperOut OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "This indicates that the peripheral is out of paper.
                off (0),
                paper-out-or-paper-mount (1),
                manual-paper-feed-needed (2)
         For some peripherals, such as the HP LaserJet IIISi printer
         or HP DesignJet plotter, this value is always a zero (0)."
::= { gdStatusEntry 8 }


gdStatusPaperJam OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "This indicates that the peripheral has a paper jam.
              off (0),
              paper-jam(1)
         For some peripherals, such as the HP LaserJet IIISi printer
         or HP DesignJet plotter, this value is always a zero (0)."
::= { gdStatusEntry 9 }


gdStatusTonerLow OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "This indicates that the peripheral has a low toner condition.
              off (0),
              toner-low (1),
              no-toner-cartridge (2)
         For some peripherals, such as the HP LaserJet IIISi printer
         or HP DesignJet plotter, this value is always a zero (0)."
::= { gdStatusEntry 10 }


gdStatusPagePunt OBJECT-TYPE
    SYNTAX      Integer32 (0..255)
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "This indicates that the peripheral did not receive data fast
         enough to keep up with the print engine when generating a page.
         For some peripherals, such as the HP LaserJet IIISi printer
         or HP DesignJet plotter, this value is always a zero (0)."
::= { gdStatusEntry 11 }


gdStatusMemoryOut OBJECT-TYPE
    SYNTAX      Integer32 (0..255)
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "This indicates that the peripheral did not have enough memory
         to render an image on a page.
         For some peripherals, such as the HP LaserJet IIISi printer
         or HP DesignJet plotter, this value is always a zero (0)."
::= { gdStatusEntry 12 }


gdStatusIoActive OBJECT-TYPE
    SYNTAX      Integer32 (0..255)
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "This indicates that the peripheral is processing data from
         this I/O interface card. For some peripherals, such as the
         HP LaserJet IIISi printer or HP DesignJet plotter,
         this value is always a zero (0).

         For X.20.06 firmware and later firmware releases, this object is 
         not relevant. In order not to break legacy applications which call this
         object in multi-varbind requests, this value is always zero (0)."
::= { gdStatusEntry 13 }


gdStatusBusy OBJECT-TYPE
    SYNTAX      Integer32 (0..255)
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "This indicates that the peripheral is busy processing
         print/plot data.
         For some peripherals, such as the HP LaserJet IIISi printer
         or HP DesignJet plotter, this value is always a zero (0)."
::= { gdStatusEntry 14 }


gdStatusWait OBJECT-TYPE
    SYNTAX      Integer32 (0..255)
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "This indicates that the peripheral is waiting for print/plot
         data to process.
         For some peripherals, such as the HP LaserJet IIISi printer
         or HP DesignJet plotter, this value is always a zero (0)."
::= { gdStatusEntry 15 }


gdStatusInitialize OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "This indicates that the peripheral is initializing or
         warming up.
              off (0),
              initializing (1),
              warm-up(2)
         For some peripherals, such as the HP LaserJet IIISi printer
         or HP DesignJet plotter, this value is always a zero (0)."
::= { gdStatusEntry 16 }


gdStatusDoorOpen OBJECT-TYPE
    SYNTAX      Integer32 (0..255)
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "This indicates that the peripheral cover or door is open.
         For some peripherals, such as the HP LaserJet IIISi printer
         or HP DesignJet plotter, this value is always a zero (0)."
::= { gdStatusEntry 17 }


gdStatusPrinting OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "This indicates that the peripheral is printing or otherwise
         marking or moving paper.
              off (0),
              ordinary-page (1),
              test-fonts-config-or-start-page (2)
         For some peripherals, such as the HP LaserJet IIISi printer
         or HP DesignJet plotter, this value is always a zero (0)."
::= { gdStatusEntry 18 }


gdStatusPaperOutput OBJECT-TYPE
    SYNTAX      Integer32
    ACCESS      read-only
    STATUS      current
       DESCRIPTION "This indicates that the peripheral has a paper output problem
         such as the output storage bin being full.
              off (0),
              output-storage-full (1)
         For some peripherals, such as the HP LaserJet IIISi printer
         or HP DesignJet plotter, this value is always a zero (0)."
::= { gdStatusEntry 19 }


photo-access-card-error OBJECT-TYPE
    SYNTAX      INTEGER {
                          ePhotoCardAccessNoError(0),
                          ePhotoCardSmartMediaUpsideDown(1),
                          ePhotoCardMediaNotFullyInserted(2),
                          ePhotoCardMoreThenOneInSlots(3),
                          ePhotoCardReadError(4),
                          ePhotoCardRemovedWhileReading(5),
                          ePhotoCardBadFileWhilePrinting(6),
                          ePhotoCardNotInSlot(7),
                          ePhotoCardContainsNoPhotos(8),
                          ePhotoCardWriteError(9),
                          ePhotoCardRemovedWhileWriting(10),
                          ePhotoCardUnknownError(999)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Specifies the error reason for most recent unsucessful photo		
                card access.
                Additional information:
                Specifies the error reason for most recent unsucessful photo
                card access."
::= { photo-job 2 }


energy-star OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Returns or changes the Energy Star sleep value. If the value		
                is greater than zero, then the device will go into energy		
                saving sleep mode after the print engine has been idle for the		
                number of seconds specified by this object. A value of zero		
                means Energy Star is disabled and the device will not go to		
                sleep based on print engine idle time. The value must be		
                non-negative.
                Additional information:
                The product will always be in
                sleep mode when not processing data.  This object will
                always return a value of 1."
::= { settings-system 1 }


sleep-mode OBJECT-TYPE
    SYNTAX      INTEGER {
                          eFalse(1),
                          eTrue(2)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Returns eTrue if the device is in energy saving sleep mode,		
                otherwise returns eFalse. Setting SLEEP-MODE to eFalse causes		
                the device to wake up, if it is in sleep mode. Setting		
                SLEEP-MODE to eTrue causes the device to go into sleep mode.
                Additional information:
                The product will always be in
                sleep mode except when either processing a print job or
                in an error state."
::= { settings-system 2 }


service-password OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      write-only
    STATUS      optional
       DESCRIPTION "When set to the password value, other service related objects		
                become 'visible' (i.e readable) and/or become writable. When		
                written with any other value, the service related objects		
                become 'hidden' (i.e. are no longer readable) and/or are not		
                longer writable. The objects that can be effected by the		
                SERVICE-PASSWORD object include: SERIAL-NUMBER and		
                TOTAL-ENGINE-PAGE-COUNT. The password value, and the list of		
                objects effected by the SERVICE-PASSWORD being set to the		
                correct value, should be documented in the device POS.
                Additional information:
                The objects that can be effected by the SERVICE-
                PASSWORD are:  SCANNER-JAM-PAGE-COUNT, SCANNER-ADF-PAGE
                -COUNT, SCAN-ADF-PAGE-COUNT, SCANNER-RETRIEVE-SCANLINE,
                SCANNER-MOTOR-CONTROL, COPIER-ADF-PAGE-COUNT, COPIER-
                PRINT-PAGE-COUNT, TOTAL-ENGINE-PAGE-COUNT, PRINT-ENGINE-
                JAM-COUNT, PRINT-ENGINE-MISPICK-COUNT, CLEAR-NVRAM"
::= { settings-system 9 }


device-configure-generic-language-prompt OBJECT-TYPE
    SYNTAX      INTEGER {
                          eDisabled(1),
                          eEnabled(2)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "This object is used to determine whether to prompt the user to		
                enter the appropriate language.
                Additional information:
                This object is used to determine whether to 
                		     prompt the user to enter the appropriate language
                	   	     at boot."
::= { device-configure 10 }


device-configure-generic-country-prompt OBJECT-TYPE
    SYNTAX      INTEGER {
                          eDisabled(1),
                          eEnabled(2)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION " This object is used to determine whether to prompt the user to		
                enter the appropriate country at boot.
                Additional information:
                This object is used to determine whether to
                	 	     prompt the user to enter the appropriate country
                	    	     at boot."
::= { device-configure 11 }


on-off-line OBJECT-TYPE
    SYNTAX      INTEGER {
                          eOnline(1),
                          eOffline(2)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "To bring the PDL processing sub-system on or off line. If the		
                device is a printer, then the printer does not process print		
                job data when the printer is off line. PML communication		
                persists.
                Additional information:
                The value of this object is eOnline
                whenever the printer is in the ready state.  This object
                will return eOffline only when an alert is active.  For
                example, the printer will go eOffline if the cover is
                open, if the toner cartridge is removed, or if the paper
                trays are all empty.  It is not possible to change the
                state of the printer with this object.  "
::= { status-system 5 }


auto-continue OBJECT-TYPE
    SYNTAX      INTEGER {
                          eOff(1),
                          eOn(2)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Indicates if the device will automatically continue after		
                encountering a continuable error. If AUTO-CONTINUE is set to		
                eOn, the device will automatically generate continue event to		
                acknowledge continuable errors. If AUTO-CONTINUE is set to		
                eOff, then some other continue event will have to acknowledge		
                the continuable error."
::= { status-system 7 }


install-date OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(0..14))
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Identifies the date that the device was installed. The format		
                of the string is 'YYYYMMDDHHmmZ'. Where:    	
                    YYYY is the year.    	
                    MM is the month (1-12).    	
                    DD is the day (1-31).    	
                    HH is the hour of the day (0-23).    	
                    mm are the minutes (0-59).    	
                    'Z' designates Greenwich Mean Time; if 'Z' not specified,		
                        value is local time.    	
                Device POS must specify the conditions for setting this		
                object.
                Additional information:
                Identifies the date that the device was installed. The
                format of the string is 'YYYYMMDDHHmmZ'. Where:
                YYYY is the year.
                MM is the month (1-12).
                DD is the day (1-31).	
                HH is the hour of the day (0-23).
                mm are the minutes (0-59).
                'Z' designates Greenwich Mean Time; if 'Z' not specified,
                value is local time.
                
                On Products without a real-time clock this
                object has the inital value of 'INVALID'.  While in
                the invalid state the object may written to.  Once the 
                initial install date has been written a new intall date
                can not be written without resetting the object to 'INVALID'.
                
                The behavior on products with real-time clocks is different.
                The object is set to the initial real-time clock value, usually
                this is '199000300000'.  Manufacturing sets the real-time
                clock to the correct date and sets the INSTALL-DATE to 'INVALID'.
                Then when the customer turns on the printer for the first time
                the install date is reset."
::= { status-system 8 }


show-address OBJECT-TYPE
    SYNTAX      INTEGER {
                          eAuto(3),
                          eOff(1)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "If this object is set to eAuto, and the device has an IP		
                address, the IP address of the device will be shown with the		
                READY message. If this object is set to eOff, the IP address		
                will not be shown."
::= { display-status 3 }


job-input-auto-continue-timeout OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The number of seconds the device waits after a job related		
                continuable error occurs before automatically continuing. An		
                example job related continuable error is the job requesting a		
                media size that is not available. After the timeout expires,		
                the device will continue processing the job as if a continue		
                event occurred, such as the front panel continue key being		
                pressed. If the value is -1, the device does not automatically		
                continue after a job related continuable error occurs. If the		
                value is 0, the device immediately continues. If the value is		
                greater than 0, the value represents the timeout value in		
                seconds."
::= { status-system 35 }


job-input-auto-continue-mode OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or sets the device behavior when the desired media is		
                not currently available.    	
                    cCancelJob - The device cancels the job. The device POS		
                        should explain what happens if this item is not the		
                        only item in the collection.    	
                    cAutoMediaSizeOverride - The device is allowed to		
                        substitute a different size media.    	
                    cAutoMediaNameOverride - The device is allowed to		
                        substitute a different media name.    	
                    cUSMediaSizeOverride - The device is allowed to substitute		
                        US media sizes (letter, etc.) for ISO media sizes (A4,		
                        etc.).    	
                    cISOMediaSizeOverride - The device is allowed to substitute		
                        ISO media sizes (A4, etc.) for US media sizes (letter,		
                        etc.).   "
::= { status-system 36 }


control-panel-button-press OBJECT-TYPE
    SYNTAX      INTEGER {
                          eGoButton(1),
                          eBackButton(13),
                          eNumericButton0(16),
                          eNumericButton1(17),
                          eNumericButton2(18),
                          eNumericButton3(19),
                          eNumericButton4(20),
                          eNumericButton5(21),
                          eNumericButton6(22),
                          eNumericButton7(23),
                          eNumericButton8(24),
                          eNumericButton9(25),
                          eAsterickButton(30),
                          ePoundButton(31),
                          eCopyButton(36),
                          eStartFaxButton(42),
                          eBackButton(13),
                          eQuestionMarkButton(14)
		   }
    ACCESS      write-only
    STATUS      optional
       DESCRIPTION "Writing this object simulates pressing a button on the control		
                panel. Reading it will return the last key pressed either on		
                the control panel or via PML. The device POS will specify which		
                keys are supported.
                Additional information:
                Writing this object simulates pressing a 
                		button on the control panel."
::= { status-system 60 }


clear-nvram OBJECT-TYPE
    SYNTAX      INTEGER {
                          eClearUnprotectedNVRAM(1),
                          eClearProtectedNVRAM(2),
                          eClearCompleteNVRAM(3)
		   }
    ACCESS      write-only
    STATUS      optional
       DESCRIPTION "Writing this object causes the specified NVRAM init option to		
                be performed. Depending on the option, some (or all) of the		
                permanent storage area will be completely erased. This object		
                is only writable wen the SERVICE-PASSWORD has been set		
                correctly. NOTE: This considerably more destructive than		
                setting the prtGeneralReset object to ePresetToFactoryDefaults		
                since it destroys page counts, serial number, and other items		
                not normally affected by ePresetToFactoryDefaults.		
                eClearUnprotectedNVRAM - clears unprotected NVRAM		
                eClearProtectedNVRAM - clears protected NVRAM		
                eClearCompleteNVRAM - clears both protected nd unprotected		
                NVRAM.
                Additional information:
                Writing this object causes the specified NVRAM init option to
                		be performed. Depending on the option, some (or all) of the
                		permanent storage area will be completely erased. This object
                		is only writable when the SERVICE-PASSWORD has been set
                		correctly. NOTE: This considerably more destructive than
                		setting the prtGeneralReset object to ePresetToFactoryDefaults
                		since it destroys page counts, serial number, and other items
                		not normally affected by ePresetToFactoryDefaults.
                		eClearUnprotectedNVRAM - clears unprotected NVRAM
                		eClearProtectedNVRAM - clears protected NVRAM
                		eClearCompleteNVRAM - clears both protected nd unprotected
                		NVRAM."
::= { status-system 68 }


model-number OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Identifies the device model number as listed in the HP		
                corporate price list (e.g. C2121A for DeskJet 500C). The string		
                is as specific as possible. Products should note in POS if the		
                model number on the CPL changes but the device reports the		
                previous model number. If the model number changes based on the		
                installed options, the POS should indicate if only the base		
                model number is returned, or if the device senses the installed		
                options and returns the correct model number. If possible,		
                encode the model number in a symbol set (like Roman-8) that		
                matches the ASCII character set and limit the characters used		
                to ASCII characters.
                Additional information:
                Identifies the device model number as listed in the HP
                corporate price list (e.g. C2121A for DeskJet 500C)."
::= { id 1 }


model-name OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Identifies the device model name (e.g. ''DeskJet 1200C''). The		
                string is as specific as possible. Capitalization and spacing		
                should match family naming conventions. Products should note in		
                POS if the model name on the HP corporate price list changes		
                but the device reports the previous device name. If the model		
                name changes based on the installed options, the POS should		
                indicate if only the base model name is returned, or if the		
                device senses the installed options and returns the correct		
                model name. If possible, encode the model name in a symbol set		
                (like Roman-8) that matches the ASCII character set and limit		
                the characters used to ASCII characters.
                Additional information:
                The value of this object changes based on the
                installed options. 
                
                Since the value of this object is frequently used in
                displaying a list of printers, it is kept relatively
                short in case systems have limited width for their
                display area."
::= { id 2 }


serial-number OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(0..10))
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Identifies the serial number for the device. If the		
                SERIAL-NUMBER object is set by the user, then setting the		
                object does not need to be protected. If the SERIAL-NUMBER		
                object is set at the factory, then the SERVICE-PASSWORD object		
                must be set correctly before the SERIAL-NUMBER object is		
                writable. If this is a writable object, the POS should indicate		
                the maximum supported string length. If possible, encode the		
                serial number in a symbol set (like Roman-8) that matches the		
                ASCII character set and limit the characters used to ASCII		
                characters.
                Additional information:
                This value is initially set to the default 
                value of XXXXXXXXXX."
::= { id 3 }


fw-rom-datecode OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Identifies the base system firmware date code. The date code		
                will be encoded in the yyyymmdd format. There may be several		
                versions of the base system firmware. The date code associated		
                with the version of the base system firmware that is being used		
                is reported. There may be other date code objects for other		
                specific modules such as fonts, localization modules, etc.;		
                these other datecode objects are device specific."
::= { id 5 }


device-name OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "User defined device name. The POS should indicate the maximum		
                supported string length. If the user entered string is too		
                long, the device will store as much as possible and will return		
                the <OKNearestLegal ValueSubstituted>.Additional information:
                The maximum supported string length is 32
                characters.  If the user entered string is too long, the
                device will store the first 32 characters and will
                return the <noError> status."
::= { id 10 }


asset-number OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(0..8))
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "User defined asset number. The POS should indicate the maximum		
                supported string length. If the user entered string is too		
                long, the device will store as much as possible and will return		
                the <OKNearestLegal ValueSubstituted>.Additional information:
                The maximum supported string length is 8
                characters.  If the user entered string is too long, the
                device will store the first 8 characters and will return
                the <noError> status."
::= { id 12 }


simm1-type OBJECT-TYPE
    SYNTAX      INTEGER {
                          eEmpty(1),
                          eUnknown(2),
                          eUnSupported(3),
                          eReadOnlyMemory(4),
                          eVolatileRandomAccessMemory(5),
                          eRamRom(9)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Returns an indication of the type of option installed in SIMM		
                slot 1.    	
                    eEmpty means the device did not detect any option installed		
                        in the interface slot.    	
                    eUnknown means the device doesn't recognize the installed		
                        option.    	
                    eUnSupported means the device recognizes the installed		
                        option, but does not support the option.    	
                    eReadOnlyMemory means the installed option contains ROM		
                        Ics.    	
                    eVolatileRandomAccessMemory means the installed option		
                        contains RAM ICs that loose data when the power is		
                        turned off.    	
                    eNonVolatileRandomAccessMemory means that the installed		
                        option contains RAM ICs that do not loose data when the		
                        power is turned off.    	
                    eFlashMemory means that the installed option contains a		
                        type of non-volatile RAM that needs to be erased before		
                        it can be written.    	
                    eDiskDrive means the installed option contains a disk		
                        drive.    	
                    eRamRom means the installed option contains both volatile		
                        random access memory and read only memory.    	
                    eInputPHD means the installed option is an input paper		
                        handling device.    	
                    eOutputPHD means the installed option is an output paper		
                        handling device. eIOCard means the installed option is		
                        an I/O card.   
                Additional information:
                This object is used to describe DIMMs
                instead of SIMMs on the product.  eRamRom is
                used to denote a combo dimm."
::= { simm1 4 }


simm1-capacity OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Returns an indication of the capacity of the SIMM installed in		
                SIMM slot 1. The capacity is dependent on the type of option,		
                as indicated by the SIMM1-TYPE object. This object has no		
                meaning if the installed option type is eUnknown or		
                eReadOnlyMemory. This object contains the size, in bytes, if		
                the installed option type is eVolatileRandomAccessMemory,		
                eNonVolatileRandomAccessMemory, eFlashMemory, or eDiskDrive. If		
                the type of the installed option is eRamRom, this object		
                contains the size, in bytes, of the random access memory. If		
                the type of the installed option is eInputPHD, the capacity		
                indicates the number of input trays supported by the installed		
                option. If the type of the installed option is eOutputPHD, the		
                capacity indicates the number of output bins supported by the		
                installed option. If the type of the installed option is		
                eIOCard, the capacity indicates the number of logical I/O ports		
                supported by the I/O card.
                Additional information:
                Returns an indication of the capacity of
                the installed option in bytes.  This object is not
                supported unless the SIMM1-TYPE type is
                eVolatileRandomAccessMemory or eRamRom.  For eRamRom
                only the size of the Ram portion of the simm (dimm) is
                returned."
::= { simm1 5 }


self-test OBJECT-TYPE
    SYNTAX      INTEGER {
                          eNotInASelfTest(1),
                          eNonDestructiveSelfTest(4)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Writing this object allows a device self test to be started.		
                Reading this object provides an indication what self-test is		
                currently executing, if any. Actual self-test operation is		
                device specific. A self test may not be allowed at any		
                arbitrary time. If the device supports the requested self test,		
                but can not start the execution of the self test when		
                requested, the device will respond with		
                <genErr>. If a non-destructive self		
                test is being started, the device will generate a response		
                before the self test is completed. RECOMMENDATION: If the		
                device is ready (i.e. the NOT-READY-PRINTER object does not		
                contain any items, except maybe being off-line) and is idle		
                (i.e. the NOT-IDLE object does not contain any items), this		
                request should always succeed. This provides a mechanism for		
                driver writers to always determine if the action will succeed		
                or not.
                Additional information:
                The eNonDestructiveSelfTest performs
                limited testing on the printer and its attached paper
                handling devices.  After the self-test is complete a
                configuration page is printed.  The recommended way to
                cause a configuration page to be printed is to use the
                PRINT-INTERNAL-PAGE object.  A continuous self test
                cannot be started or terminated using this OID.
                
                When the printer is idle, setting this object to
                eNonDestructiveSelfTest results in a status of <noError> and
                a value of eNonDestructiveSelfTest being returned.  If
                the printer is not idle (whether printing an external
                job, printing an internal page or running self test), a
                status of <genErr> status will
                be returned with a value of eNotInASelfTest.
                
                When the printer is idle, setting this object to
                eNonDestructiveSelfTest causes the configuration page to
                be formatted and put in the printer's print queue.
                
                Attempting to set this object before the configuration
                page has completed being formatted and printed will
                cause <genErr> status to be
                returned with a value of eNotInASelfTest.
                
                After the configuration page is in the queue, a get on
                this object will return a value of eNotInASelfTest.
                
                Setting the value to eNotInASelfTest is not supported on
                the product.  Once the test has started, it
                will finish printing.
                
                Likewise, if the PRINT-INTERNAL-PAGE object is set to a
                valid value and that page has not printed when this
                object is set to eNonDestructiveSelfTest, a status of
                <genErr> status with a value of
                eNotInASelfTest will be returned until the internal page
                has printed."
::= { test 1 }


print-internal-page OBJECT-TYPE
    SYNTAX      INTEGER {
                          eNotPrintingAnInternalPage(1),
                          ePrintingAnUnknownInternalPage(2),
                          eDeviceDemoPage1ConfigurationPage(3),
                          eDeviceDemoPage2(4),
                          eDeviceDemoPage7MenuMap(9),
                          eDeviceUsagePage(10),
                          eServicePage(13),
                          eSuppliesPage(101),
                          eDeviceCleaningPage(253),
                          ePCLFontList1(350),
                          ePCLXLFontList1(353),
                          ePostScriptFontList1(450),
                          eNetworkConfigPage(1200),
                          eFaxActivityLogPage(1304),
                          ePrintQualityDiagnosticPage(1409),
                          eColorUsageLog(1412)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Writing this object to a value other than		
                eNotPrintingAnInternalPage causes the device to attempt to		
                print an internally generated page. Reading this object		
                provides an indication what internally generated page is		
                currently being printed, if any. The actual page is device		
                specific. Some devices may support continuously printing an		
                internally generated page. Setting this object to		
                eNotPrintingAnInternalPage terminates continuously printing		
                internally generated pages. An internally generated page may		
                not be allowed to be printed at any arbitrary time; under what		
                conditions it will succeed or fail is device specific. If the		
                device supports the requested page, but can not start printing		
                the page when requested, the device will respond with		
                <genErr>. RECOMMENDATION: If the		
                device is ready (i.e. the NOT-READY-PRINTER object does not		
                contain any items, except maybe being off-line) and is idle		
                (i.e. the NOT-IDLE object does not contain any items), this		
                request should always succeed. This provides a mechanism for		
                driver writers to always determine if the action will succeed		
                or not.
                Additional information:
                eDeviceDemoPage2 is the printer demo page.
                ePCLFontList1 is the PCL typeface list,
                ePostScriptFontList1 is the PostScript font list, and
                eDeviceDemoPage1ConfigurationPage is the selftest page.
                
                The product does not support continuously
                printing a demo page.
                
                The printer will queue requests if it is currently busy.
                
                When this object is set to a valid value and the printer
                is idle, the status returned is <noError> and the value
                returned is ePrintingAnUnknownInternalPage.
                
                Setting this object to a valid value causes the desired
                page to be formatted and put in the printer's print
                queue.  While the page is being formatted, and the
                printer remains in a testing state, a get on this object
                will return the value ePrintingAnUnknownInternalPage.
                The return value will be eNotPrintingAnInternal page if
                the printer is not in a testing state, and the internal
                page is done being formatted.
                
                The user will not be able to set
                eNotPrintingAnInternalPage or
                ePrintingAnUnknownInternalPage, and the return status
                will be <badValue> with a return
                value of eNotPrintingAnInternalPage.
                
                ePostScriptFontList1 and ePCLFontList1 will not be 
                		valid values unless postscript and PCL, respectively, 
                		are installed in the printer.  If postscript (PCL)
                is not installed and the user attempts to set
                ePostScriptFontList1 (ePCLFontList1), the return status 
                		will be <badValue> with a return 
                		value of eNotPrintingAnInternalPage.
                
                Setting through DMCMD will cause a 15 second delay in
                printing."
::= { test 2 }


cancel-job OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Cancels the print job whose ID matches the value written to the		
                CANCEL-JOB object. The host first learns the job ID using the		
                CURRENT-JOB-PARSING-ID command. If the printer has completely		
                processed the job, the printer responds with		
                <badValue>. If the value of the		
                CURRENT-JOB-PARSING-ID is smaller than the value written to the		
                CANCEL-JOB object, then the printer responds with		
                <badValue>. When read, returns the value		
                of the last job ID what was canceled, or -1 to indicate no job		
                has been canceled.
                Additional information:
                Cancels the print job whose ID matches the value written to the
                		CANCEL-JOB object. The host first learns the job ID using the
                		CURRENT-JOB-PARSING-ID command. If the printer has completely
                		processed the job, the printer responds with
                		<badValue>. If the value of the
                		CURRENT-JOB-PARSING-ID is smaller than the value written to the
                		CANCEL-JOB object, then the printer responds with
                		<badValue>. When read, returns the value
                		of the last job ID what was canceled, or -1 to indicate no job
                		has been canceled."
::= { settings-job 2 }


job-info-change-id OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(16))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Returns the current value of an object in the job-info sub-tree		
                whose value has changed. Define the object identifier for the		
                object whose value has changed as		
                job-info.required-field.optional-field.job-id. job-info		
                represents the OID prefix of all objects in the job-info		
                sub-tree. Required-field represents the OID field value that		
                follows the job-info prefix. Since some objects in the job-info		
                sub-tree have two OID fields between the job-info prefix and		
                the job-id, the optional-field represents the OID field between		
                the required-field and the job-id field, if present. Using this		
                definition, the format for the JOB-INFO-CHANGE-ID binary value		
                can be described as follows:    	
                    Bytes 0-3 : required-field    	
                    Bytes 4-7 : optional-field, or all zeros if there    	
                    is no optional field    	
                    Bytes 8-11: Job ID.    	
                    Bytes 12-n : The value of the object job-info.		
                        required-field.optional-field.job-id.    	
                All multi-byte values stored in Motorola (big-endian) format,		
                where the most significant byte occurs first.
                Additional information:
                The product will use this object
                to report changes of the job-info-pages-printed and
                job-info-state objects.  The required-field (bytes 0
                through 3) will designate whether the change to be
                reported involves the pages printed (13) or job state
                (15).  The optional-field (bytes 4 through 7) will
                always be zeroes.  The value-field (bytes 12 through 15)
                will contain the new value for pages printed or job
                state cast to a 32-bit integer."
::= { settings-job 3 }


current-job-parsing-id OBJECT-TYPE
    SYNTAX      INTEGER(-1..32767)
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Contains the printer assigned job identification for the job		
                currently being processed by the processing PDL sub-system. The		
                job ID is a monotonically increasing number. The job ID may be		
                reset to zero at power-up and may roll over to zero after		
                reaching some maximum value.
                Additional information:
                A value of -1 is returned when the printer
                is not parsing a job.
                
                When data for a new job is detected, this object is
                updated (the job may or may not turn out to be a Null
                Job).  (A job is considered to be a 'null job' if it has
                no name or job attribute, causes no pages to be printed,
                and consumes MIN_JOB_SIZE (9) or fewer bytes.)  See the
                Job Boundary ERS for details on what constitutes a job
                boundary.
                
                Some job-info- objects are created when the first data
                bytes are received.  If the printer determines that the
                job is a Null Job, the job-info- objects related to the
                Null Job are deleted.  The product retains
                the job-info- objects for the MAX_JOBS_IN_LIST (12) most
                recent jobs that are not Null Jobs.
                
                The first job received after power-up will have job ID 1,
                and the job ID will increment to 32767 before rolling 
                to zero.  To distinguish whether a power cycle or a 
                rollover causes a reduction in the job ID value, the 
                object prtGeneralConfigChanges can be watched and if it 
                increments at the same time as the drop is observed in
                the value of CURRENT-JOB-PARSING-ID, then a power cycle
                is the most likely cause."
::= { job-being-parsed 1 }


job-info-io-source OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Indicates which I/O source, the print job was received over.		
                The value maps to port numbering scheme supported in the		
                DEVICE/SOURCE-SUBSYSTEM/IO/PORTS sub-tree.
                Additional information:
                The product does not
                support the DEVICE/SOURCE-SUBSYSTEM/IO/PORTS sub-tree."
::= { job-info 11 }


job-info-outbins-used OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Indicates which output bins this job has delivered printed		
                pages to. The last OID field for this dynamic object contains		
                the job ID.
                Additional information:
                The product has only 1 output bin.
                cOutbin1 is the top/face-down bin."
::= { job-info 20 }


error1-time-stamp OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Contains some sort of time stamp indicating when error 1		
                occurred. Example time stamps include the actual time the error		
                occurred (in seconds since Jan. 1, 1970), and the total engine		
                page count. The device POS documents the meaning of the time		
                stamp.
                Additional information:
                This item contains the engine page count
                when the error occurred.
                
                If there is currently no error entry for this object, a
                '0' will be returned.  If ERROR1-CODE object also
                returns '0', then an error has not yet been logged for
                this object
                
                See ERROR1-CODE for an explanation of the order used for
                storing errors."
::= { error1 1 }


error1-code OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Contains a device specific error code. Each device POS should		
                list what errors are logged to the error log and the meaning of		
                each supported error code value.
                Additional information:
                Returns a device specific error code.  If
                the error code returned is '0', then the printer has not
                yet logged an error for this object.  When the maximum
                number of errors is reached (10 on the
                		product), and a new error occurs, the error in
                ERROR1-CODE will be replaced by the one in ERROR2-CODE,
                and so on until the last error object will be given the
                value of the new error.
                
                The error category is returned in the upper 16 bits,
                either 79 (for service) or 0 (for support).  The lower
                16 bits encodes the specific error.  If an error is not
                a 79 service error, the value of this object is the PJL
                USTATUS code.  If it is a 79 service error, the lower 16
                bits contain the PJL USTATUS code.
                
                The types of errors reported for the product are:
                49 Service Error
                50-67  Service Error
                69 Service Error
                70-72 Service Error
                79 Service Errors
                		  Access Error
                		  Address Error
                		  ASIC fault
                		  Asserts
                		  Bad Beam Detect
                		  Bad E-Label
                		  Bad Fan
                		  Bad Fuser
                		  Bad Malfunction
                		  Bad MIO
                		  Bad Scanner Motor
                		  Data Communication Error
                		  Engine Communication Error
                		  Format Error
                		  Genunine HP Supply Installed
                		  Illegal Instruction
                		  Insufficient Memory
                		  Invalid Personality
                		  Laser Malfunction
                		  MIO Buffer Overflow
                		  MIO Connection Break
                		  Missing E-Label
                		  Non-HP Supply Detected
                		  NVRAM Error
                		  NVRAM Service Error
                		  Parallel Buffer Overflow
                		  Print Page Punt
                		  Priviledge Violation
                		  Trace Fault
                		  Unimplemented Line-a Opcode
                		  Unimplemented Line-f Opcode
                		  Uninitialized Interrupt"
::= { error1 2 }


error2-time-stamp OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Contains some sort of time stamp indicating when error 2		
                occurred. Example time stamps include the actual time the error		
                occurred (in seconds since Jan. 1, 1970), and the total engine		
                page count. The device POS documents the meaning of the time		
                stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error2 1 }


error2-code OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Contains a device specific error code. Each device POS should		
                list what errors are logged to the error log and the meaning of		
                each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error2 2 }


error3-time-stamp OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Contains some sort of time stamp indicating when error 3		
                occurred. Example time stamps include the actual time the error		
                occurred (in seconds since Jan. 1, 1970), and the total engine		
                page count. The device POS documents the meaning of the time		
                stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error3 1 }


error3-code OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Contains a device specific error code. Each device POS should		
                list what errors are logged to the error log and the meaning of		
                each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error3 2 }


error4-time-stamp OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Contains some sort of time stamp indicating when error 4		
                occurred. Example time stamps include the actual time the error		
                occurred (in seconds since Jan. 1, 1970), and the total engine		
                page count. The device POS documents the meaning of the time		
                stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error4 1 }


error4-code OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Contains a device specific error code. Each device POS should		
                list what errors are logged to the error log and the meaning of		
                each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error4 2 }


error5-time-stamp OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Contains some sort of time stamp indicating when error 5		
                occurred. Example time stamps include the actual time the error		
                occurred (in seconds since Jan. 1, 1970), and the total engine		
                page count. The device POS documents the meaning of the time		
                stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error5 1 }


error5-code OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Contains a device specific error code. Each device POS should		
                list what errors are logged to the error log and the meaning of		
                each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error5 2 }


error6-time-stamp OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Contains some sort of time stamp indicating when error 6		
                occurred. Example time stamps include the actual time the error		
                occurred (in seconds since Jan. 1, 1970), and the total engine		
                page count. The device POS documents the meaning of the time		
                stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error6 1 }


error6-code OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Contains a device specific error code. Each device POS should		
                list what errors are logged to the error log and the meaning of		
                each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error6 2 }


error7-time-stamp OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Contains some sort of time stamp indicating when error 7		
                occurred. Example time stamps include the actual time the error		
                occurred (in seconds since Jan. 1, 1970), and the total engine		
                page count. The device POS documents the meaning of the time		
                stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error7 1 }


error7-code OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Contains a device specific error code. Each device POS should		
                list what errors are logged to the error log and the meaning of		
                each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error7 2 }


error8-time-stamp OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Contains some sort of time stamp indicating when error 8		
                occurred. Example time stamps include the actual time the error		
                occurred (in seconds since Jan. 1, 1970), and the total engine		
                page count. The device POS documents the meaning of the time		
                stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error8 1 }


error8-code OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Contains a device specific error code. Each device POS should		
                list what errors are logged to the error log and the meaning of		
                each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error8 2 }


error9-time-stamp OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Contains some sort of time stamp indicating when error 9		
                occurred. Example time stamps include the actual time the error		
                occurred (in seconds since Jan. 1, 1970), and the total engine		
                page count. The device POS documents the meaning of the time		
                stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error9 1 }


error9-code OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Contains a device specific error code. Each device POS should		
                list what errors are logged to the error log and the meaning of		
                each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error9 2 }


error10-time-stamp OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Contains some sort of time stamp indicating when error 10		
                occurred. Example time stamps include the actual time the error		
                occurred (in seconds since Jan. 1, 1970), and the total engine		
                page count. The device POS documents the meaning of the time		
                stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error10 1 }


error10-code OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Contains a device specific error code. Each device POS should		
                list what errors are logged to the error log and the meaning of		
                each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error10 2 }


firmware-download-version OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "This object will return a string value representing the current		
                revision of firmware that the printer is operating with. This		
                is used to determine if code needs to be upgraded when an		
                firmware bundle comes in, in an upgrade job.
                Additional information:
                This object will return a string value representing the current		
                revision of firmware that the printer is operating with. This		
                is used to determine if code needs to be upgraded when an		
                firmware bundle comes in, in an upgrade job."
::= { firmware-download 7 }


io-timeout OBJECT-TYPE
    SYNTAX      INTEGER(5..7200)
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The amount of time, in seconds, to wait for more print job data		
                to be received before an I/O timeout occurs. The I/O channel		
                being timed is the I/O channel that received the data		
                associated with the current print job. If an I/O timeout		
                occurs, the PDL processing sub-system assumes all the data		
                associated with the current print job has been received, and		
                processes the end of job in an PDL specific manner. The POS		
                specifies the supported values.
                Additional information:
                If an I/O timeout occurs,the PDL processing
                sub-system will consider it an end of job condition only
                if there is data from another I/O subsystem waiting to be
                processed. 
                The supported values are 5 to 7200 seconds.  Setting to a
                value outside the supported range returns
                <badValue> status."
::= { settings-io 1 }


io-switch OBJECT-TYPE
    SYNTAX      INTEGER {
                          eYes(1)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Indicates if the device will switch between I/O channels when a		
                job boundary is encountered and print job data is available on		
                another I/O channel."
::= { settings-io 2 }


default-copies OBJECT-TYPE
    SYNTAX      INTEGER(1..999)
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or changes default copies. Default copies is the		
                default values used by the PDL to control the number of copies		
                of each page in the print job that are printed. The print job		
                can override this value. The list of supported values should be		
                documented in the device POS.
                Additional information:
                 The supported values are 1 through 999.
                Setting to an unsupported value causes the printer to
                substitute in a snap value and to return
                <noError> status.
                The snaps are as follows:
                <1 snaps to
                >999 snaps to 999"
::= { settings-pdl 4 }


default-vertical-black-resolution OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or changes the value of the default vertical black		
                resolution. The units are dots per inch.
                Additional information:
                In the product, changing this OID
                also causes DEFAULT-HORIZONTAL-BLACK RESOLUTION to
                change.  DEFAULT-HORIZONTAL-BLACK-RESOLUTION and
                DEFAULT-VERTICAL-BLACK-RESOLUTION must always be the
                same. The supported values are 300, 600, and 1200.
                		
                Setting to an unsupported value causes the printer to
                substitute in a snap value and to return
                <noError> status. 
                
                The snap values are as follows:
                <450 will snap to 300
                >=450 and <900 will snap to 600
                >=900 will snap to 1200"
::= { settings-pdl 8 }


default-horizontal-black-resolution OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or changes the value of the default horizontal black		
                resolution. The units are dots per inch.
                Additional information:
                In the product, changing this OID
                also causes DEFAULT-VERTICAL-BLACK RESOLUTION to change.
                DEFAULT-HORIZONTAL-BLACK-RESOLUTION and
                DEFAULT-VERTICAL-BLACK-RESOLUTION must always be the
                same.  The supported values are 300, 600 and 1200.
                
                
                Setting to an unsupported value causes the printer to
                substitute in a snap value and to return
                <noError> status.
                
                The snap values are as follows:
                <450 snaps to 300
                >=450 and <900 snaps to 600
                >=900 snaps to 1200"
::= { settings-pdl 9 }


default-lines-per-page OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or changes the default number of lines per page. The		
                POS indicates the supported values. An unsupported value causes		
                the printer to use the closest supported value, causing the		
                printer to return the <noError>.
                Additional information:
                The supported values in the product
                are 5 to 128.  Setting to an unsupported value
                causes the printer to substitute in a snap value and to
                return <noError> status.
                
                The snap values are as follows:
                <5 snaps to 5
                >128 snaps to 128"
::= { settings-pdl 11 }


default-vmi OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or changes the default vertical motion index. The unit		
                of measure for VMI is centipoints per line. The POS indicates		
                the supported values. An unsupported value causes the printer		
                to use the closest supported value, causing the printer to		
                return <noError>.
                Additional information:
                Setting this object may cause
                DEFAULT-LINES-PER-PAGE to change."
::= { settings-pdl 12 }


default-media-size OBJECT-TYPE
    SYNTAX      INTEGER {
                          eUSExecutive(1),
                          eUSLetter(2),
                          eUSLegal(3),
                          eFoolscap(10),
                          eISOandJISA6(24),
                          eISOandJISA5(25),
                          eISOandJISA4(26),
                          ePRC16K195X270(34),
                          eJISB6(44),
                          eJISB5(45),
                          eJapansePostcardSingle(71),
                          eJapansePostcardDouble(72),
                          eIndexCard5x8(75),
                          ePhoto4x6(76),
                          eMonarch(80),
                          eNo10Envelope(83),
                          eROC16K184X260(89),
                          eInternationalDL(90),
                          eInternationalC5(91),
                          eInternationalB5(100),
                          ePhoto10x15(118)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "This indicates the default media size. A write of an		
                unsupported value causes an <ErrorInvalidOrUnsupported Value>.		Complete list of supported media sizes along with their		
                dimensions are listed in the ''Media Size Table'' near the end		
                of this document. (for a full list of media size enums see the		
                end of this file) "
::= { settings-pdl 13 }


cold-reset-media-size OBJECT-TYPE
    SYNTAX      INTEGER {
                          eUSLetter(2),
                          eISOandJISA4(26)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or sets the media size that is used as the		
                DEFAULT-MEDIA-SIZE when a cold reset occurs."
::= { settings-pdl 19 }


default-media-name OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or sets the media name that is used until the media		
                name is changed by a print job command.
                Additional information:
                This string must be one of the MEDIAn-NAME 
                objects, except it cannot be set to ANY. 
                The value of this object is saved across 
                		            a power cycle."
::= { settings-pdl 22 }


reprint OBJECT-TYPE
    SYNTAX      INTEGER {
                          eOff(1),
                          eOn(2),
                          eAuto(3)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or changes the reprint (jam recovery) setting. If eOn,		
                then the device will reprint pages jammed pages. If eOff, the		
                device will not attempt to reprint jammed pages. If eAuto, a		
                device dependent algorithm (which should be documented in the		
                POS) will be used to determine if the page gets reprinted. This		
                object controls all PDLs, unless a specific PDL supports its		
                own reprint control mechanism. To date, only PostScript has a		
                PDL reprint control mechanism.
                Additional information:
                Setting this object when the printer is not
                idle, may cause a status of <noError> to be returned, but
                the new value will not take effect until a job boundary
                is reached.  If a get is done on object before the job
                boundary is reached, the value last set will be
                returned.
                
                When the value is set to eOff, pages will not be stored
                in the printer, and in the event of a paper jam, will
                have to be reprinted.  When the value is set to eOn,
                pages will be stored until delivery, therefore, in the
                event of a paper jam, the page will be reprinted.
                
                When the value is set to eAuto, the printer will behave
                as though it is eOff when there is less than seven
                megabytes of memory installed in the printer.  When
                additional memory is installed, to total at least seven
                megabytes of RAM, the setting of eAuto will behave as
                though it was set to eOn."
::= { settings-pdl 36 }


wide-a4 OBJECT-TYPE
    SYNTAX      INTEGER {
                          eOff(1),
                          eOn(2)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or changes the wide A4 logical page size setting. If		
                eOn, then the margins/printable area of A4 paper will be		
                changed to allow 80 10-pitch characters to be printed on a		
                single line. If eOff then the industry standard A4 logical page		
                size is used."
::= { settings-pdl 37 }


dark-courier OBJECT-TYPE
    SYNTAX      INTEGER {
                          eOff(1),
                          eOn(2)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or changes the dark Courier setting. If eOn, then the		
                Courier font used will approximate the same darkness as the		
                LaserJet III printer. If eOff, then the Courier font used will		
                approximate the same darkness as the LaserJet 4 printer."
::= { settings-pdl 38 }


default-bits-per-pixel OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Controls the number of levels used (per pixel) when printing		
                grayscale or color images."
::= { settings-pdl 39 }


pcl-total-page-count OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Total number of PCL pages printed by the device."
::= { pdl-pcl 5 }


pcl-default-font-height OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or changes the default PCL height. Height is an		
                approximate measure of the body of the type in centipoints. A		
                centipoint is 1/7200 inch. Height applies only to proportional		
                fonts. Point size, in points, can be converted to font height,		
                in centipoints, by multiplying the point size by 100. The POS		
                indicates the supported values. An unsupported value causes the		
                printer to use the closest supported value, causing the printer		
                to return <noError>. ''Closest'' means		
                the smallest absolute difference.
                Additional information:
                This object refers to the font point size
                with 400 representing the smallest settable font (4) and
                99975 representing the largest settable font (999.75).
                The default of 1200 is a font point size of 12.
                
                Supported values range from 400 to 99975.  Setting to an
                unsupported value causes the printer to substitute in a
                snap value and to return
                <noError> status.
                
                The snap values are as follows:
                <=400 snaps to 400
                >=99975 snaps to 99975
                
                Fonts are settable to the nearest quarter point size
                (i.e.  10, 10.25, 10.50, 10.75).  Unsupported values in
                the range 401 to 99974 snap DOWN to the previous
                supported value (i.e 25293 snaps to 25275 or 75038 snaps
                to 75025)."
::= { pdl-pcl 13 }


pcl-default-font-source OBJECT-TYPE
    SYNTAX      INTEGER {
                          eInternal(1),
                          ePermanentSoft(2),
                          eRomSimm1(10)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or changes the value of the default font source		
                variable in NVRAM."
::= { pdl-pcl 14 }


pcl-default-font-number OBJECT-TYPE
    SYNTAX      INTEGER(0..255)
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or changes the value of the default font number		
                variable in NVRAM. Writing an unsupported value causes the		
                printer to generate an <badValue>.
                Additional information:
                Valid numbers or 0 - 255, but only font
                numbers that are included in the PCL FONT LIST are
                selectable."
::= { pdl-pcl 15 }


pcl-default-font-width OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or changes the default PCL font width. Width is		
                expressed as the width of a character in centipoints. A		
                centipoint is 1/7200 inch. Width applies only to fixed space		
                fonts. Pitch, in character per inch, can be converted to font		
                width, in centipoints, by dividing 7200 by the pitch. The POS		
                indicates the supported values. An unsupported value causes the		
                printer to use the closest supported value, causing the printer		
                to return <noError>. ''Closest'' means		
                the smallest absolute difference.
                Additional information:
                Setting to an unsupported value causes the
                printer to substitue in a snap value (listed below) and
                return <noError> status.
                
                The snap values for pitch are as follow:
                <=44 snaps to 44
                >=9999 snaps to 9999
                
                Unsupported values in the range 44 - 9999 (.44 - 99.99)
                snap DOWN to the next supported value."
::= { pdl-pcl 16 }


postscript-total-page-count OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Total number of PostScript pages printed by the device."
::= { pdl-postscript 5 }


postscript-print-errors OBJECT-TYPE
    SYNTAX      INTEGER {
                          eOff(1),
                          eOn(2)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or changes the value of the print PostScript errors		
                setting. If eOn, PostScript prints an error page showing the		
                error encountered and the stack at the time of the error.
                Additional information:
                Returns or changes the value of the print PostScript errors		
                setting. If eOn, PostScript prints an error page showing the		
                error encountered and the stack at the time of the error."
::= { pdl-postscript 11 }


pjl-password OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Returns PJL password, if the password is not set (zero). If the		
                password is set, then attempting to retrieve the password		
                causes an <genErr> to occur and will return		
                the <NullValue>."
::= { pjl 1 }


print-density OBJECT-TYPE
    SYNTAX      INTEGER(1..5)
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or sets the print density setting. Print density is the		
                instantaneous amount of marking agent applied to the paper		
                while printing. A value of zero has the lowest print density,		
                yielding a lighter page. A value of 10 has the highest print		
                density, yielding a darker page. Each POS should document what		
                values in the 0 to 10 range are supported.
                Additional information:
                When this value is written, the page
                pipeline will be flushed (all pages being printed are
                completed, no new ones are started), the new density
                setting is set and printing resumes.  The acutal change
                in print density may be gradual over several pages.
                
                The supported values are 1 through 5.  Setting to an 
                unsupported value causes the printer to substitue in a
                a snap value and to return <noError>
                status.
                
                The snap values are as follows:
                <1 snaps to 1
                >5 snaps to 5."
::= { settings-prt-eng 5 }


invalid-personality-reports-enabled OBJECT-TYPE
    SYNTAX      INTEGER {
                          eDisabled(1),
                          eEnabled(2)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Read or configure wether invalid personality reports are		
                enabled or disabled for a product."
::= { settings-prt-eng 18 }


fast-first-page-out OBJECT-TYPE
    SYNTAX      INTEGER {
                          eOff(1),
                          eOn(2)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Return or set the value of the fast first page out setting.
                Additional information:
                Return or set the value of the fast first page out setting."
::= { settings-prt-eng 19 }


total-engine-page-count OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Total number of pages printed by the device. POS indicates if		
                the total engine page count is kept in NVRAM, and the maximum		
                supported value before the page count rolls over to zero.
                Additional information:
                This object is stored in NVRAM.  The maximum value of
                this count is 1000000 before it rolls over to zero."
::= { status-prt-eng 5 }


print-engine-jam-count OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Total number of pages jammed in the print engine's life time.		
                The POS indicates if the total jam count is kept in NVRAM and		
                the maximum supported value before the jam count rolls over to		
                zero.
                Additional information:
                This object is stored in NVRAM. The maximum value of 
                this count is 65000 before it rolls over to zero."
::= { status-prt-eng 34 }


print-engine-mispick-count OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Total number of pages mispicked in the print engine's life		
                time. The POS indicates if the total mispick count is kept in		
                NVRAM and the maximum supported value before the mispick count		
                rolls over to zero.
                Additional information:
                This object is stored in NVRAM. The maximum value of 
                this count is 65000 before it rolls over to zero."
::= { status-prt-eng 35 }


duplex-page-count OBJECT-TYPE
    SYNTAX      INTEGER(0..1000000)
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Total number of sheets of media that have been duplex printed.		
                A sheet is counted if it travels through the duplex page path,		
                regardless of whether or not marks are made on the page. The		
                POS will indicate if the value is kept in NVRAM.
                Additional information:
                Total number of sheets of media that have been duplex printed.		
                	     A sheet is counted if it travels through the duplex page path,		
                	     regardless of whether or not marks are made on the page. 
                	                     This object is stored in NVRAM. The maximum value of 
                		     this count is 1000000 before it rolls over to zero."
::= { status-prt-eng 22 }


print-engine-revision OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Print engine revision string.
                Additional information:
                Print engine revision string."
::= { status-prt-eng 26 }


mp-tray OBJECT-TYPE
    SYNTAX      INTEGER {
                          eManual(1),
                          eCassette(2),
                          eFirst(3)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or changes the value of the multi-purpose (MP) tray		
                configuration variable. The MP tray can be configured to		
                operate as an additional input tray (eCassette), a manual feed		
                slot (eManual), or in a manner compatible with the LaserJet III		
                manual feed slot (eFirst). If configured for eFirst, if media		
                is present in the MP tray, that media is used (assuming the		
                size matches and the print job didn't specify another tray)		
                until the MP tray is empty.
                Additional information:
                Returns or changes the value of the multi-purpose (MP) tray
                configuration variable. The MP tray can be configured to
                operate as an additional input tray (eCassette), a manual feed
                slot (eManual), or in a manner compatible with the LaserJet III
                manual feed slot (eFirst). If configured for eFirst, if media
                is present in the MP tray, that media is used (assuming the
                size matches and the print job didn't specify another tray)
                until the MP tray is empty."
::= { settings-intray 5 }


tray-lock OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or changes the list of locked input trays. The printer		
                only pulls media from a locked input tray when the input tray		
                is specifically requested by the print job.
                Additional information:
                Returns or changes the list of locked input trays. The printer
                only pulls media from a locked input tray when the input tray
                is specifically requested by the print job."
::= { settings-intray 6 }


custom-paper-dim-unit OBJECT-TYPE
    SYNTAX      INTEGER {
                          eTenThousandthsOfInches(3),
                          eMicrometers(4)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The units of measure used to specify the width and height of		
                the printer's custom paper. The unit of measure of		
                eTenThousandthsOfInches is 0.0001 inches.
                Additional information:
                The only valid values for this object are
                eTenThousandthsOfInches (3), and eMicrometers (4).  The
                data for this object is stored in NVRAM."
::= { settings-intray 7 }


custom-paper-feed-dim OBJECT-TYPE
    SYNTAX      INTEGER(50000..140000)
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Sets the printer's custom paper dimension in the feed direction		
                (direction parallel to the direction of paper feeding). The		
                value for this object is specified in micrometers or		
                tenthousandths of an inch, depending upon the value of		
                CUSTOM-PAPER-DIM-UNIT. The valid range is engine-dependent and		
                should be documented in the POS for each product.
                Additional information:
                 The valid range is 50000 to 140000 if 
                CUSTOM-PAPER_DIM_UNIT is eTenThousandthsOfInches or 127000 to 
                355600 if CUSTOM-PAPER-DIM-UNIT is ePmicrometers.  Attempts
                to set this object outside the valid range will result in a 
                return value of ERROR_INVALID_OR_UNSUPPORTED_VALUE."
::= { settings-intray 8 }


custom-paper-xfeed-dim OBJECT-TYPE
    SYNTAX      INTEGER(30000..85000)
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Sets the printer's custom paper dimension in the cross-feed		
                direction (direction ninety degrees relative to the direction		
                of paper feeding). The value for this object is specified in		
                micrometers or tenthousandths of an inch, depending upon the		
                value of CUSTOM-PAPER-DIM-UNIT. The valid range is		
                engine-dependent and should be documented in the POS for each		
                product.
                Additional information:
                The valid range for the product
                		is 30000 to 85000 if CUSTOM-PAPER-DIM-UNIT is
                eTenThousandthsOfInches or 76200 to 215900 if
                CUSTOM-PAPER-DIM-UNIT is ePmicrometers.  Attempts to set
                this object outside the valid range will result in a
                return value of <badValue>."
::= { settings-intray 9 }


tray1-media-size-loaded OBJECT-TYPE
    SYNTAX      INTEGER {
                          eUSExecutive(1),
                          eUSLetter(2),
                          eUSLegal(3),
                          eFoolscap(10),
                          eISOandJISA6(24),
                          eISOandJISA5(25),
                          eISOandJISA4(26),
                          ePRC16K195X270(34),
                          eJISB6(44),
                          eJISB5(45),
                          eJapansePostcardSingle(71),
                          eJapansePostcardDouble(72),
                          eIndexCard5x8(75),
                          ePhoto4x6(76),
                          eMonarch(80),
                          eNo10Envelope(83),
                          eROC16K184X260(89),
                          eInternationalDL(90),
                          eInternationalC5(91),
                          eInternationalB5(100),
                          ePhoto10x15(118)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns the media size that is currently configuredconfigured		
                in tray #1. This object can be set to indicate the media size		
                currently loaded, if the printer supports input trays that can		
                not sense the media size. Complete list of supported media		
                sizes along with their dimensions are listed in the ''Media		
                Size Table'' near the end of this document.
                Additional information:
                Returns the media size that is currently configured in tray #1."
::= { intray1 1 }


tray1-fuser-temperature OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The fuser temperature to be used when printing media from Tray		
                1. The value zero is the default temperature. Values less than		
                zero are progressively lower and values greater than zero are		
                progressively higher. The range of values supported is device		
                specific.
                Additional information:
                The fuser temperature to be used when printing media from Tray
                1. The value zero is the default temperature. Values less than
                zero are progressively lower and values greater than zero are
                progressively higher. The range of values supported is device
                specific."
::= { intray1 13 }


tray2-media-size-loaded OBJECT-TYPE
    SYNTAX      INTEGER {
                          eUSExecutive(1),
                          eUSLetter(2),
                          eUSLegal(3),
                          eFoolscap(10),
                          eISOandJISA6(24),
                          eISOandJISA5(25),
                          eISOandJISA4(26),
                          ePRC16K195X270(34),
                          eJISB6(44),
                          eJISB5(45),
                          eJapansePostcardSingle(71),
                          eJapansePostcardDouble(72),
                          eIndexCard5x8(75),
                          ePhoto4x6(76),
                          eMonarch(80),
                          eNo10Envelope(83),
                          eROC16K184X260(89),
                          eInternationalDL(90),
                          eInternationalC5(91),
                          eInternationalB5(100),
                          ePhoto10x15(118)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns the media size that is currently configured in tray #2.		
                Complete list of supported media sizes along with their		
                dimensions are listed in the ''Media Size Table'' near the end		
                of this document."
::= { intray2 1 }


tray2-fuser-temperature OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The fuser temperature to be used when printing media from Tray		
                2. The value zero is the default temperature. Values less than		
                zero are progressively lower and values greater than zero are		
                progressively higher. The range of values supported is device		
                specific.
                Additional information:
                The fuser temperature to be used when printing media from Tray
                2. The value zero is the default temperature. Values less than
                zero are progressively lower and values greater than zero are
                progressively higher. The range of values supported is device
                specific."
::= { intray2 13 }


tray3-media-size-loaded OBJECT-TYPE
    SYNTAX      INTEGER {
                          eUSExecutive(1),
                          eUSLetter(2),
                          eUSLegal(3),
                          eFoolscap(10),
                          eISOandJISA6(24),
                          eISOandJISA5(25),
                          eISOandJISA4(26),
                          ePRC16K195X270(34),
                          eJISB6(44),
                          eJISB5(45),
                          eJapansePostcardSingle(71),
                          eJapansePostcardDouble(72),
                          eIndexCard5x8(75),
                          ePhoto4x6(76),
                          eROC16K184X260(89),
                          ePhoto10x15(118)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns the media size that is currently configured in tray #3.		
                Complete list of supported media sizes along with their		
                dimensions are listed in the ''Media Size Table'' near the end		
                of this document."
::= { intray3 1 }


tray3-fuser-temperature OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The fuser temperature to be used when printing media from Tray		
                3. The value zero is the default temperature. Values less than		
                zero are progressively lower and values greater than zero are		
                progressively higher. The range of values supported is device		
                specific.
                Additional information:
                The fuser temperature to be used when printing media from Tray
                3. The value zero is the default temperature. Values less than
                zero are progressively lower and values greater than zero are
                progressively higher. The range of values supported is device
                specific."
::= { intray3 13 }


default-ret OBJECT-TYPE
    SYNTAX      INTEGER {
                          eOff(1),
                          eLight(2),
                          eMedium(3),
                          eDark(4)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or changes the Resolution Enhancement Technology		
                setting. Devices that only support eOff and eOn should map all		
                other values to eOn and always return the same non-eOff value		
                to indicate on. The list of supported values should be		
                documented in the device POS."
::= { imaging 5 }


default-print-quality OBJECT-TYPE
    SYNTAX      INTEGER(0..100)
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or sets the default print quality. A value of zero has		
                the lowest print quality. A value of 100 has the highest print		
                quality. Each POS should document what values in the 0 to 100		
                range are supported.
                Additional information:
                The product supports
                DEFAULT-PRINT-QUALITY in 300, 600, and 1200 dpi.  
                
                In the product, the supported values are 0 and
                100.  A value of zero has the lowest print quality
                (ECONOMODE=ON), thus minimizes the amount of toner used
                to print a page.  A value of 100 has the highest print
                quality (ECONOMODE=OFF), thus uses more toner to print a
                page.  Setting to an unsupported value outside of the 0
                to 100 range causes the printer to return
                <badValue> status.
                
                Setting to an unsupported value inside of the 0 to 100
                range causes the printer to substitute in a snap value
                (listed below) and to return
                <noError> status.
                
                The snap values are as follow:
                0 to 50 snaps to 0
                51 to 100 snaps to 100"
::= { imaging 7 }


media-names-available OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The value of this object controls which of the MEDIAx-NAME		
                objects are supported. If a bit is set to zero, then attempting		
                to get or set the corresponding MEDIAx-NAME objects will return		
                <noSuchName>.
                Additional information:
                Since this object is read-only, the corresponding MEDIAx 
                			objects will always be available.  The DEFAULTS below
                represent which MediaNameX is available on this product
                of the total possible available defined in SYNTAX, so the 
                collection is like a bitfield. Raptor does not support 
                cMediaName32Available"
::= { settings-print-media 1 }


media1-name OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(1..3))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Media 1 name.
                Additional information:
                The symbol set for this string is Roman-8."
::= { media1 1 }


media1-engine-media-mode OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The engine processing characteristics that are to be applied to		
                this media. The processing characteristics are device		
                specific.
                Additional information:
                The engine processing characteristics that are to
                be applied to this media type. Currently, 'engine
                processing characteristics' denotes changes to
                fusing temperature and/or transfer roller voltage."
::= { media1 4 }


media2-name OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(1..5))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Media 2 name.
                Additional information:
                The symbol set for this string is Roman-8."
::= { media2 1 }


media2-engine-media-mode OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The engine processing characteristics that are to be applied to		
                this media. The processing characteristics are device		
                specific.
                Additional information:
                See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media2 4 }


media3-name OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Media 3 name.
                Additional information:
                The symbol set for this string is Roman-8."
::= { media3 1 }


media3-engine-media-mode OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The engine processing characteristics that are to be applied to		
                this media. The processing characteristics are device		
                specific.
                Additional information:
                See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media3 4 }


media4-name OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Media 4 name.
                Additional information:
                The symbol set for this string is Roman-8."
::= { media4 1 }


media4-engine-media-mode OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The engine processing characteristics that are to be applied to		
                this media. The processing characteristics are device		
                specific.
                Additional information:
                See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media4 4 }


media5-name OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Media 5 name.
                Additional information:
                The symbol set for this string is Roman-8."
::= { media5 1 }


media5-engine-media-mode OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The engine processing characteristics that are to be applied to		
                this media. The processing characteristics are device		
                specific.
                Additional information:
                See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media5 4 }


media6-name OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(1..5))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Media 6 name.
                Additional information:
                The symbol set for this string is Roman-8."
::= { media6 1 }


media6-engine-media-mode OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The engine processing characteristics that are to be applied to		
                this media. The processing characteristics are device		
                specific.
                Additional information:
                See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media6 4 }


media7-name OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(1..10))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Media 7 name.
                Additional information:
                The symbol set for this string is Roman-8."
::= { media7 1 }


media7-engine-media-mode OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The engine processing characteristics that are to be applied to		
                this media. The processing characteristics are device		
                specific.
                Additional information:
                See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media7 4 }


media8-name OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(1..10))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Media 8 name.
                Additional information:
                The symbol set for this string is Roman-8."
::= { media8 1 }


media8-engine-media-mode OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The engine processing characteristics that are to be applied to		
                this media. The processing characteristics are device		
                specific.
                Additional information:
                See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media8 4 }


media9-name OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(1..12))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Media 9 name.
                Additional information:
                The symbol set for this string is Roman-8."
::= { media9 1 }


media9-engine-media-mode OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The engine processing characteristics that are to be applied to		
                this media. The processing characteristics are device		
                specific.
                Additional information:
                See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media9 4 }


media10-name OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(1..10))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Media 10 name.
                Additional information:
                The symbol set for this string is Roman-8."
::= { media10 1 }


media10-engine-media-mode OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The engine processing characteristics that are to be applied to		
                this media. The processing characteristics are device		
                specific.
                Additional information:
                See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media10 4 }


media11-name OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Media 11 name.
                Additional information:
                The symbol set for this string is Roman-8."
::= { media11 1 }


media11-engine-media-mode OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The engine processing characteristics that are to be applied to		
                this media. The processing characteristics are device		
                specific.
                Additional information:
                See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media11 4 }


media12-name OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Media 12 name.
                Additional information:
                The symbol set for this string is Roman-8."
::= { media12 1 }


media12-engine-media-mode OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The engine processing characteristics that are to be applied to		
                this media. The processing characteristics are device		
                specific.
                Additional information:
                See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media12 4 }


media13-name OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Media 13 name.
                Additional information:
                The symbol set for this string is Roman-8."
::= { media13 1 }


media13-engine-media-mode OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The engine processing characteristics that are to be applied to		
                this media. The processing characteristics are device		
                specific.
                Additional information:
                See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media13 4 }


media14-name OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(1..6))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Media 14 name.
                Additional information:
                The symbol set for this string is Roman-8."
::= { media14 1 }


media14-engine-media-mode OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The engine processing characteristics that are to be applied to		
                this media. The processing characteristics are device		
                specific.
                Additional information:
                See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media14 4 }


media15-name OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(1..4))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Media 15 name.
                Additional information:
                The symbol set for this string is Roman-8."
::= { media15 1 }


media15-engine-media-mode OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The engine processing characteristics that are to be applied to		
                this media. The processing characteristics are device		
                specific.
                Additional information:
                See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media15 4 }


media16-name OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(1..8))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Media 16 name.
                Additional information:
                The symbol set for this string is Roman-8."
::= { media16 1 }


media16-engine-media-mode OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The engine processing characteristics that are to be applied to		
                this media. The processing characteristics are device		
                specific.
                Additional information:
                See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media16 4 }


media17-name OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(1..5))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Media 17 name.
                Additional information:
                The symbol set for this string is Roman-8."
::= { media17 1 }


media17-engine-media-mode OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The engine processing characteristics that are to be applied to		
                this media. The processing characteristics are device		
                specific.
                Additional information:
                See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media17 4 }


media18-name OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Media 18 name.
                Additional information:
                The symbol set for this string is Roman-8."
::= { media18 1 }


media18-engine-media-mode OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The engine processing characteristics that are to be applied to		
                this media. The processing characteristics are device		
                specific.
                Additional information:
                See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media18 4 }


media19-name OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(1..10))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Media 19 name.
                Additional information:
                The symbol set for this string is Roman-8."
::= { media19 1 }


media19-engine-media-mode OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The engine processing characteristics that are to be applied to		
                this media. The processing characteristics are device		
                specific.
                Additional information:
                See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media19 4 }


media20-name OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(1..5))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Media 20 name.
                Additional information:
                The symbol set for this string is Roman-8."
::= { media20 1 }


media20-engine-media-mode OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The engine processing characteristics that are to be applied to		
                this media. The processing characteristics are device		
                specific.
                Additional information:
                See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media20 4 }


media21-name OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(1..5))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Media 21 name.
                Additional information:
                The symbol set for this string is Roman-8."
::= { media21 1 }


media21-engine-media-mode OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The engine processing characteristics that are to be applied to		
                this media. The processing characteristics are device		
                specific.
                Additional information:
                See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media21 4 }


media22-name OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(1..5))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Media 22 name.
                Additional information:
                The symbol set for this string is Roman-8."
::= { media22 1 }


media22-engine-media-mode OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The engine processing characteristics that are to be applied to		
                this media. The processing characteristics are device		
                specific.
                Additional information:
                See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media22 4 }


media23-name OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(1..5))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Media 23 name.
                Additional information:
                The symbol set for this string is Roman-8."
::= { media23 1 }


media23-engine-media-mode OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The engine processing characteristics that are to be applied to		
                this media. The processing characteristics are device		
                specific.
                Additional information:
                See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media23 4 }


media24-name OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Media 24 name.
                Additional information:
                The symbol set for this string is Roman-8."
::= { media24 1 }


media24-engine-media-mode OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The engine processing characteristics that are to be applied to		
                this media. The processing characteristics are device		
                specific.
                Additional information:
                See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media24 4 }


engine-media-modes-supported1 OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The list of engine media modes supported by the device. The		
                modes are each separated by a comma character. An example		
                string would be: 'Normal,Rough,Low,Vellum'."
::= { media-modes 1 }


consumable-status-serial-number OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "This object is used to report the serial number for this		
                consumable."
::= { consumable-status 3 }


consumable-life-usage-units-remaining OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "This object reports the current estimate of the number of usage		
                units that remain before this supply is depleted. An installed		
                supply that cannot report such a number will return a value of		
                -2. It is the reponsibility of the host application to query		
                each supply in order to determine an overall device		
                USAGE-UNITS-REMAINING number - the lowest value returned. The		
                unit of measure for this life estimate is determined by reading		
                the corresponding CONSUMABLE-LIFE-USAGE-UNITS object.
                Additional information:
                This object reports the approximate number of pages remaining
                before this supply reaches very low. An installed cartridge that
                cannot report such a number (because supply status is not
                available) will return a value of -2. If the supply life is above
                80% then this object will return ErrorActionCanNotBePerformedNow
                (or genErr if queried through SNMP)."
::= { consumables-life 1 }


consumable-life-low-threshold OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "This object is used to report and/or modify a threshold value		
                indicating the point in the life of a consumable or supply at		
                which a transition to a LOW state will occur."
::= { consumables-life 3 }


consumable-test-password OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      write-only
    STATUS      optional
       DESCRIPTION "When set with the correct integer password value this object is		
                used to enable certain device specific test capabilities. When		
                set with any incorrect integer value, this object is used to		
                disable any device specific features previously enabled by this		
                object. This object will return a response of		
                <noSuchName> whenever an attempt is made to		
                query the object rather than		
                <noSuchName> so as to hide the		
                existence of this object from external host applications."
::= { consumables-test 1 }


scanner-jam-page-count OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Indicates a count of the total pages jammed in the		
                scanner'slifetime."
::= { settings-scanner 43 }


scanner-adf-page-count OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Indicates a count of the total pages scanned through the ADF on		
                the device. This may include scan to host jobs, copyjobs, and		
                fax jobs. If only the total pages scanned to the host are		
                wanted, use SCAN-ADF-PAGE-COUNT."
::= { settings-scanner 44 }


scan-adf-page-count OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Indicates the total pages scanned through the ADF to the host		
                from the device. If the total pages scanned through the scanner		
                are needed for all features, including copy and fax jobs, use		
                the SCANNER-ADF-PAGE-COUNT object."
::= { settings-scanner 45 }


scanner-retrieve-scanline OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      write-only
    STATUS      optional
       DESCRIPTION "This object facilitates the sending of a scan line of data from		
                the scanner to a host. It grabs either raw or corrected data.		
                SERVICE-PASSWORD must be set correctly to use this object.    	
                    cScannerRequestRawScanLine - This is set by the host in		
                        order to signal to the firmware that it wants an scan		
                        line of raw (no PRNU or DSNU correction)data to be sent		
                        back up to the host.    	
                    cScannerRequestCorrectedScanLine - This is set by the host		
                        in order to signal to the firmware that it wants a scan		
                        line of corrected (PRNU or DSNU correction) data to be		
                        sent back up to the host.   	
                    cScannerSendDataRequest - This is set by firmware to		
                        indicate that it has acquired the scan line from scan		
                        engine and is ready to send the data to the host.    	
                    cScannerSendDataOK - This is set by the host to indicate		
                        that it is ready to receive the data from the device.		
                           	
                    cScannerSendDataDone - This is set by the firmware to		
                        indicate that the transfer of data is complete.    	
                    cScannerPickSheet - This is set by the host to tell the		
                        device to pick and stage the sheet of paper in the ADF.		
                           	
                    cScannerFlushSheet - This is set by the host to tell the		
                        device to flush the sheet of paper currently in the		
                        device.   
                Additional information:
                This object is meant to be used by Manufacturing
                		 in order to facilitate the sending of a scan line of data from
                		 the scanner over HDT.  It
                		 grabs either raw or corrected data.
                
                cScannerRequestRawScanLine - This is set by the host in order 
                to signal to the firmware that it wants an scan line of raw 
                (no PRNU or DSNU correction)data to be sent back up to the 
                host.  
                
                cScannerRequestCorrectedScanLine - This is set by the host in 
                order to signal to the firmware that it wants a scan line of 
                corrected (PRNU or DSNU correction) data to be sent back up to
                the host. 
                
                cScannerSendDataRequest - This is set by firmware to indicate 
                that it has acquired the scan line from scan engine and is 
                ready to send the data to the host. 
                
                cScannerSendDataOK - This is set by the host to
                indicate that it is ready to receive the data from the device. 
                
                cScannerSendDataDone - This is set by the firmware to indicate
                that the transfer of data is complete. 
                
                cScannerPickSheet - This is used for manufacturing to drop the
                scan bogey to prevent damage during shipping.  For LaserJet 
                3200, it was used to load a sheet in the ADF for shipping.
                
                cScannerFlushSheet - This is set by the host to tell the 
                device to flush the sheet of paper currently in the device."
::= { settings-scanner 48 }


scanner-motor-control OBJECT-TYPE
    SYNTAX      INTEGER(-500..4680)
    ACCESS      write-only
    STATUS      optional
       DESCRIPTION "This objects is set to the number of steps that the scan motor		
                should move. SERVICE-PASSWORD must be setcorrectly to use this		
                object.
                Additional information:
                This objects is set to the number of steps that
                		the scan motor should move. It is meant to be used by Manufacturing
                		in order to position the scanner shipping blocks.
                The minimum value is -240, and the maximum is 4680.  The value
                set for this object will move the scan motor relative to the
                home position.  A value of 0 will use the find home algorithm
                to move the scan motor home."
::= { settings-scanner 49 }


scanner-scanline-statistics OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "This object is used to obtain statistics about the scan line		
                that was previously obtained using the		
                SCANNER-RETRIEVE-SCANLINE object. Just as SERVICE-PASSWORD must		
                be set correctly for SCANNER-RETRIEVE-SCANLINE, it must be set		
                correctly to use this object as well.
                Additional information:
                This object is used to obtain statistics about
                the scan line that was previously grabbed using the SCANNER_
                RETRIEVE_SCANLINE object, max string is 256 bytes.  The format
                is the following: max red value; position; min red value; position;
                max red pixel to pixel difference; position; red mean; max blue value; 
                position; min blue value; position; max blue pixel to pixel difference;
                position; blue mean; max green value; position; min green value; 
                position; max green pixel to pixel difference; position; green mean;
                red num band1; red num band2; red num band3;blue num band1; blue num band2; 
                blue num band3;green num band1; green num band2; green num band3;red num left;
                red num right; blue num left; blue num right; green num left; green num right;
                width in pixels; red num bad; blue num bad; green num bad;red num clipped;
                blue num clipped; green num clipped;
                As the device performs a scan calibration at startup these values will change
                to the calibrated value and the default value will be modified. Hence testing
                for default will not make any sense unless the calibration at the starup is
                aborted."
::= { settings-scanner 51 }


scan-control-descriptor OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Describes the control language and formats supported for this		
                scanner.
                Additional information:
                This string is also used by Jetdirect Embedded WebScan"
::= { settings-scanner 52 }


scan-flatbed-page-count OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "This object tracks the page count for the pages scanned from		
                the flatbed."
::= { settings-scanner 73 }


scanner-flatbed-page-count OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "This object tracks the page count for the pages scanned for all		
                jobs from the flatbed. This includes scan to host jobs, fax		
                jobs, and copy jobs. "
::= { settings-scanner 74 }


scanner-modular-hardware OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Used to specify whether optional hardware is installed or not
                Additional information:
                This HP LaserJet MFP uses this object to allow
                a host to query whether or not it has an ADF installed, 
                		Letter/A4 flatbed, or Legal flatbed."
::= { settings-scanner 75 }


scanner-clock-edge-modifiers OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "This object accesses a table used by firmware to modify clock		
                edge values for CCD scanner modules.
                Additional information:
                This object accesses a table used by firmware to modify
                	  	   clock edge values for CCD scanner modules."
::= { settings-scanner 84 }


scan-clock-edges OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Returns a table of clock edges used by the scanner.
                Additional information:
                Returns a table of clock edges used by the scanner."
::= { settings-scanner 85 }


scan-emulate-copy OBJECT-TYPE
    SYNTAX      INTEGER {
                          eNo(1),
                          eYes(2)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Setting this object to eYes will cause firmware to run the next		
                scan job as if it were a copy job, using copy values for		
                scanner h/w and image processing, and then return the data to		
                the host as if it were a scan job. Setting this object to eNo		
                will cause firmware to process scan jobs in the normal way.
                Additional information:
                Setting this object to eYes will cause firmware to run
                the next scan job as if it were a copy job, using copy
                values for scanner h/w and image processing, and then
                return the data to the host as if it were a scan job.
                Setting this object to eNo will cause firmware to
                process scan jobs in the normal way."
::= { settings-scanner 86 }


scan-calibration-target OBJECT-TYPE
    SYNTAX      INTEGER {
                          eWhiteSheet(1),
                          ePlaten(2)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "This object is used by the host to check which type of		
                calibration this scan device supports. The device pos will		
                describe the meaning and intent of each type of scan		
                calibration supported.
                Additional information:
                This object is used by the host to check which
                type of calibration the firmware supports."
::= { scan-calibration 18 }


not-ready-source-scanner OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Indicates whether and why the scanner is not ready. A set bit		
                indicates a problem.
                Additional information:
                ISSUES: Timberline only used 
                cScannerFeederJam.  Tahiti does not have 
                an ADF sensor.  Can cScannerFeederEmpty still 
                be used (i.e. when the device tries to pull 
                a page, but the ADF is empty or a mispick 
                occurred).  cInvalidScannerMediaSize may be used.  
                If a page is longer that 33 inches normally this would be 
                shown to the host as a Jam.  However, can the device 
                use cInvalidScannerMediaSize instead?"
::= { status-scanner 1 }


scan-calibration-download OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Returns or changes the state of the calibration operation.    	
                    cScanCalibrationIdle - indicates that calibration is not in		
                        progress.    	
                    cScanCalibrationStart - This state is set by host to		
                        request calibration initiation. Device should not set		
                        to this state.    	
                    cScanCalibrationActive - Indicates device is in calibration		
                        mode. Device sets cScanCalibrationActive to signal		
                        calibration is in process.    	
                    cScanCalibrationAborted - Set by device to indicate		
                        calibration was prematurely terminated. Set by host		
                        when a calibration error occurs.    	
                    cScanCalibrationSendDataRequest - Set by host when host		
                        wants to send data to the device.    	
                    cScanCalibrationSendDataRequestOK - Set by the device to		
                        tell the host that the device is ready to accept data.		
                           	
                    cScanCalibrationSendDataRequestDone -Set by the device to		
                        indicate the data was received by the device.    	
                    cScanCalibrationRequestScanBuffer - Set by the host to		
                        request a buffer from the device.    	
                    cScanCalibrationDone - Set by the host to inform the device		
                        calibration is complete.    	
                The sequence of bits being set and the restrictions for setting		
                bits should be documented in the device POS.
                Additional information:
                Returns or changes the state of the calibration
                operation.
                cScanCalibrationIdle - indicates that calibration is not
                in progress.  
                cScanCalibrationStart - This state is set by host to
                request calibration initiation. Device should not set to
                this state.  
                cScanCalibrationActive - Indicates device is in
                calibration mode.  Device sets cScanCalibrationActive to
                signal calibration is in process.  
                cScanCalibrationAborted - Set by device to indicate
                calibration was prematurely terminated. Set by host when
                a calibration error occurs.  
                cScanCalibrationDone - Set by the host to inform the
                device calibration is complete.  
                
                		The device will print a calibration graph when
                		calibration is complete.The subarray indexes behaves the same way 
                as that of this object. The below are the list of subarray objects.  
                SCAN-CALIBRATION-DOWNLOAD-600 - 600 ppi scan with 600 array - host scan
                SCAN-CALIBRATION-DOWNLOAD-1200 - 1200 ppi scan with 1200 array-host scan     
                SCAN-CALIBRATION-DOWNLOAD-300-MONO - 300 ppi scan with 300 array-mono copy
                SCAN-CALIBRATION-DOWNLOAD-300-SCAN - 300 ppi scan with 600 array-host scan."
::= { status-scanner 5 }


scan-calibration-error OBJECT-TYPE
    SYNTAX      INTEGER {
                          eNoError(1),
                          eUnknownCalibrationError(2),
                          eScannerFeederEmpty(3),
                          eLowMemory(4),
                          eWriteFailed(5),
                          eScannerBusy(6),
                          eADFMispick(7),
                          eADFJam(8),
                          eUncorrectablePixels(9)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Error status of the most recent calibration session.    	
                    eNoError(1) - The calibation was successful.    	
                    eUnknownCalibrationError(2) - An unknown error occurred.   	                         
                    eScannerFeederEmpty(3) - The feeder contained nothing to		
                        scan.    	
                    eLowMemory(4) - Insufficient memory available to complete		
                        the calibration.    	
                    eWriteFailed(5) - Write to NVRAM failure.    	
                    eScannerBusy(6) - Scanner is busy.    	
                Detailed information about the cause and remedy for each error		
                should be documented in the device POS.
                Additional information:
                This object was originally defined for use on
                		Timberline. We are proposing the new enums number 7-9.
                	        Note: Option 9 would only be set during a factory calibration
                to indicate that at least one pixel was not correctable by
                the digital calibration factors."
::= { status-scanner 6 }


scanner-lamp-gain-value OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Provides PWM and analog gain for the color channels. The range		
                will vary based on scan mode. The device specific POS should		
                describe the valid range. The format is the following:   	
                    PWM value; red analog gain; green analog gain; blue analog		
                        gain.   
                Additional information:
                 The range will vary based on scan mode.  The values
                will differ from those of San Diego.  The initial value
                can be obtained at the start of warmup and the final
                value can be obtained at the end of warmup. The warmup period is about
                2 minutes.  The format is the following PWM value; red analog gain;
                green analog gain; blue analog gain;.  The valid values for PWM value
                are 580 - 730 and the valid values for analog gains are 1.00-5.80.
                The gains are reported with accuracy to 2 decimal places.
                A sample return value would be '584;1.00;1.34;1.00;' "
::= { status-scanner 8 }


scanner-light-monitor-window OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Provides the pixel at which the LMW starts, as the ratio of the		
                average LMW value to the six pixel average value. The device		
                specific pos should specify the valid ranges for each value.		
                The format is the following:   	
                    LMW position; ratio of LMWavg to 6 pixel avg.   
                Additional information:
                Provides the pixel at which the LMW starts as well as
                the ratio of the average LMW value over a 6 pixel average value.
                A algebraic representation of this ratio is:
                Average of Light Monitor Window pixels
                ______________________________________
                Average of 6 test point pixels
                
                The 6 test point pixels do not inlcude any of the Light Monitor Window.
                A sample return value would be '50;0.059;'. "
::= { status-scanner 9 }


scanner-reference-position OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Provides 3 pairs of x,y coordinates within a specified range of		
                the calibrate reference position. The device specific POS		
                should specify the valid ranges. The format is the following:		
                'x;y;x;y;x;y'
                Additional information:
                Provides x,y coordinates within 1/300 of a line of the
                calibrate reference position.  The 3 locations in order that are
                reported are the 1st Reference Mark, the 2nd Reference Mark, and
                the Document Origin.  A sample return value would be            
                80,471;2523,2914;80,471;1;34326;27,32;193;35748;28,27;194;0,0;0;0;0;0;0;0;0,0;0;0;0;0;0;0;0,0;0;0,0;0;0;0 
                The extra 0's on the end are used specifically to gather information during
                the cimation process. "
::= { status-scanner 10 }


scanner-sensor-manufacturer OBJECT-TYPE
    SYNTAX      OCTET STRING
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Reports the scan sensor manufacturer. The device specific POS		
                should list valid manufacturers.
                Additional information:
                Reports the scan sensor manufacturer.  The device specific
                POS should list valid manufacturers."
::= { status-scanner 11 }


prtGeneralConfigChanges OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Counts configuration changes that change the capabilities of
        a printer, such as the addition/deletion of input/output bins,
        the addition/deletion of interpreters, or changes in media
        size.  Such changes will often affect the capability of the
        printer to service certain types of print jobs.
        Management applications may cache infrequently changed
        configuration  information about sub-units on the printer.
        This object should be incremented whenever the agent wishes
        such applications to invalidate that cache and re-download
        all of this configuration information, thereby signaling a
        change in the printer's configuration.
        For example, if an input tray that contained paper of
        different dimensions was added, this counter would be
        incremented.
        As an additional example, this counter would not be
        incremented when an input tray is removed or the level of an
		input device changes.
                Additional information:
                This is a 32 bit counter (unsigned).  When it
                reaches its maximum value, it will roll to zero."
::= { prtGeneralEntry 1 }


prtGeneralCurrentLocalization OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The value of the prtLocalizationIndex corresponding to the
        current language, country, and character set to be used for
        localized string values that are identified as being dependent
        on the value of this object.  Note that this object does not
        apply to localized strings in the prtConsole group or to any
        object that is not explicitly identified as being localized
        according to prtGeneralCurrentLocalization."
::= { prtGeneralEntry 2 }


prtGeneralReset OBJECT-TYPE
    SYNTAX      INTEGER {
                          ePnotResetting(3),
                          ePpowerCycleReset(4),
                          ePresetToNVRAM(5),
                          ePresetToFactoryDefaults(6)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "Setting this value to `powerCycleReset', `resetToNVRAM', or
        `resetToFactoryDefaults' will result in the resetting of the
        printer.  When read, this object will always have the value
        `notResetting(3)', and a SET of the value `notResetting' shall
        have no effect on the printer.  Some of the defined values are
        optional.  However, every implementation must support at least
        the values `notResetting' and 'resetToNVRAM'.
                Additional information:
                Setting this object to ePnotResetting causes the 
                	   printer to not reset.
                
                Setting this object to ePpowerCycleReset causes this device
                to do a reset.
                
                Setting this object to 'resetToNVRAM' does NOT perform an NVRAM
                init on the product.  It causes the device to perform its power 
                on initialization routines.  All I/O buffers are reset and tests 
                normally run at power on time are executed.
                
                Setting the object to 'resetToFactoryDefaults, causes the
                device to perform its reset to factory defaults routines.
                Also, the device will perform a power cycle, which is required
                to set all variables to their factory defaults."
::= { prtGeneralEntry 3 }


prtGeneralCurrentOperator OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(0..26))
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The name of the person who is responsible for operating
          this printer. It is suggested that this string include
          information that would enable other humans to reach the operator,
          such as a phone number. As a convention to facilitate automatic
          notification of the operator by the agent or the network
          management station, the phone number, fax number or email address
          should be placed on a separate line starting with ASCII LF (hex
          0x0A) and the ASCII text string (without the quotes): 'phone: ',
          'fax: ', and 'email: ', respectively. Phone numbers may contain
          digits, whitespace and parentheses, which shall be ignored. Phone
          numbers may also include ASCII comma characters(hex 2C) that are
          used to indicate a two-second pause during the dialing sequence.
          If either the phone, fax, or email information is not available,
          then a line should not be included for this information.
          NOTE: For interoperability purposes, it is advisable to use email
          addresses formatted according to RFC 822 requirements.
                Additional information:
                The maximum supported string length is 26
                characters.
                
                If the user entered string is too long, the device will store
                as much as possible and will return the
                <noError> status."
::= { prtGeneralEntry 4 }


prtGeneralServicePerson OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(0..28))
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The name of the person responsible for servicing this
          printer. It is suggested that this string include information
          that would enable other humans to reach the service person, such
          as a phone number. As a convention to facilitate automatic
          notification of the service person by the agent or a network
          management station, the phone number, fax number or email address
          should be placed on a separate line starting with ASCII LF (hex
          0x0A) and the ASCII text string (without the quotes): 'phone: ',
          'fax: ', and 'email: ', respectively. Phone numbers may contain
          digits, whitespace and parentheses, which shall be ignored. Phone
          numbers can also include one or more ASCII comma characters(hex
          2C) to indicate a two-second pause during the dialing sequence.
          If either the phone,fax, or email information is not available,
          then a line should not included for this information.
          NOTE: For interoperability purposes, it is advisable to use email
          addresses formatted according to RFC 822 requirements.
                Additional information:
                The maximum supported string length is 28
                characters.
                
                If the user entered string is too long, the device will store
                as much as possible and will return the
                <noError> status."
::= { prtGeneralEntry 5 }


prtInputDefaultIndex OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The value of prtInputIndex corresponding to the default input
        sub-unit: that is, this object selects the default source of
        input media. 
   This value shall be -1 if there is no default input subunit specified
   for the printer as a whole.  In this case, the actual default
   input subunit may be specified by means outside the scope of this
   MIB, such as by each interpreter in a printer with multiple
   interpreters.
                Additional information:
                The default input tray is determined by the
                printer based on DEFAULT-MEDIA-SIZE, what trays are locked
                (if any), and whether or not Tray 2 is installed. 
                
                This object always returns -1, unknown."
::= { prtGeneralEntry 6 }


prtOutputDefaultIndex OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The  value of prtOutputIndex  corresponding to the default
        output sub-unit; that is, this object selects the default
        output destination. 
   This value shall be -1 if there is no default output subunit specified
   for the printer as a whole.  In this case, the actual default
   output subunit may be specified by means outside the scope of this
   MIB, such as by each interpreter in a printer with multiple
   interpreters.
                Additional information:
                The product has only one output bin, a
                face-down bin located at the top of the printer."
::= { prtGeneralEntry 7 }


prtMarkerDefaultIndex OBJECT-TYPE
    SYNTAX      INTEGER(1..65535)
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The value of prtMarkerIndex corresponding to the
        default marker sub-unit; that is, this object selects the
        default marker.
                Additional information:
                The product only has one marker subunit."
::= { prtGeneralEntry 8 }


prtMediaPathDefaultIndex OBJECT-TYPE
    SYNTAX      INTEGER(1..3)
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The value of prtMediaPathIndex corresponding to
        the default media path; that is, the selection of the
        default media path.
                Additional information:
                The only valid value for this object is 1
                (simplex)."
::= { prtGeneralEntry 9 }


prtConsoleLocalization OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The value of the prtLocalizationIndex corresponding to
        the language, country, and character set to be used for the
        console.  This localization applies both to the actual display
        on the console as well as the encoding of these console
        objects in management operations."
::= { prtGeneralEntry 10 }


prtConsoleNumberOfDisplayLines OBJECT-TYPE
    SYNTAX      INTEGER(0..65535)
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The number of lines on the printer's physical
        display.  This value is 0 if there are no lines on the
        physical display or if there is no physical display."
::= { prtGeneralEntry 11 }


prtConsoleNumberOfDisplayChars OBJECT-TYPE
    SYNTAX      INTEGER(0..65535)
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The number of characters per line displayed on the physical
        display.  This value is 0 if there are no lines on the
        physical display or if there is no physical display.
                Additional information:
                The device has a 16 character by 2 line display."
::= { prtGeneralEntry 12 }


prtConsoleDisable OBJECT-TYPE
    SYNTAX      INTEGER {
                          ePoperatorConsoleEnabled(3)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "If the object prtConsoleDisable has value
          'operatorConsoleDisabled' then input is not accepted from the
          operator console. If the object prtConsoleDisable has the value
          'operatorConsoleEnabled' then input is accepted from the
          operator console. If the object prtConsoleDisable has the value
          'operatorConsoleEnabledLevel1','operatorConsoleEnabledLevel2' or
          'operatorConsoleEnabledLevel3' then limited input is accepted
          from the operator console; the limitations are product specific,
          however, the limitations are generally less restrictive for
          operatorConsoleEnabledLevel1 than for
          operatorConsoleEnabledLeve2, which is less restrictive than
          operatorConsoleEnabledLevel3.
          The value of the prtConsoleDisable object is a type-2
          enumeration."
::= { prtGeneralEntry 13 }


prtGeneralPrinterName OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(0..32))
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "An administrator-specified name for this printer.
          Depending upon implementation of this printer, the value of this
          object may or may not be same as the value for the MIB-II
          'SysName' object.
                Additional information:
                The maximum supported string length is 32
                characters.  Length of 32 was chosen so a phone number could
                be included with the name.
                If the user-entered string is too long, the device will store
                as much as possible and will return the
                <noError> status.  The value of this
                object is saved over a power cycle."
::= { prtGeneralEntry 16 }


prtGeneralSerialNumber OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(0..11))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "A recorded serial number for this device that indexes some type 
		 device catalog or inventory. This value is usually set by the
		 device manufacturer but the MIB supports the option of 
		 writeability for this object for site-specific administration of
		 device inventory or tracking."
::= { prtGeneralEntry 17 }


prtAlertCriticalEvents OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "A running counter of the number of critical alert events
          that have been recorded in the alert table. The value of this
          object is RESET in the event of a power cycle operation (i.e.,
          the value is not persistent.
                Additional information:
                This object is set to zero every time the
                printer is turned on."
::= { prtGeneralEntry 18 }


prtAlertAllEvents OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "A running counter of the total number of alert event entries
     (critical and non-critical) that have been recorded in the
     alert table
                Additional information:
                This object is set to zero every time the
                printer is turned on.  (It is not persistent through a
                power-cycle.)"
::= { prtGeneralEntry 19 }


prtCoverDescription OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(0..255))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The manufacturer provided cover sub-mechanism  name in the
        localization specified by prtGeneralCurrentLocalization."
::= { prtCoverEntry 2 }


prtCoverStatus OBJECT-TYPE
    SYNTAX      INTEGER {
                          ePdoorOpen(3),
                          ePdoorClosed(4)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The status of this cover sub-unit."
::= { prtCoverEntry 3 }


prtLocalizationLanguage OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(0..2))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "A two character language code from ISO 639.  Examples
          en, gb, ca, fr, de."
::= { prtLocalizationEntry 2 }


prtLocalizationCountry OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(0..2))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "A two character country code from ISO 3166, a blank string
        (two space characters) shall indicate that the country is
        not defined.  Examples: US, FR, DE, ..."
::= { prtLocalizationEntry 3 }


prtLocalizationCharacterSet OBJECT-TYPE
    SYNTAX      INTEGER {
                          ePcsHPRoman8(2004),
                          ePcsISOLatin2(5),
                          ePcsISOLatinCyrillic(8),
                          ePcsISOLatin5(12),
                          ePcsISOLatinGreek(10),
                          ePcsISOLatinHebrew(11),
                          ePcsISOLatinArabic(9),
                          ePcsUnicode(2000)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The coded character set used for this localization."
::= { prtLocalizationEntry 4 }


prtStorageRefIndex OBJECT-TYPE
    SYNTAX      INTEGER(1..65535)
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The value of the hrDeviceIndex of the printer device that this
        storageEntry is associated with."
::= { prtStorageRefEntry 2 }


prtDeviceRefIndex OBJECT-TYPE
    SYNTAX      INTEGER(1..65535)
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The value of the hrDeviceIndex of the printer device that this
        deviceEntry is associated with."
::= { prtDeviceRefEntry 2 }


prtInputType OBJECT-TYPE
    SYNTAX      INTEGER {
                          ePsheetFeedAutoRemovableTray(3),
                          ePsheetFeedAutoNonRemovableTray(4)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The type of technology (discriminated primarily according to
        feeder mechanism type) employed by the input sub-unit.  Note,
        the Optional Input Class provides for a descriptor field to
        further qualify the other choice.
                Additional information:
                Tray 1 is the multi-purpose tray and is always
                present.  It supports both sheets and envelopes.  Its type is
                ePsheetFeedAutoNonRemovableTray. The tray 2 object does not 
                	   exist when the tray is NOT installed."
::= { prtInputEntry 2 }


prtInputDimUnit OBJECT-TYPE
    SYNTAX      INTEGER {
                          ePtenThousandthsOfInches(3),
                          ePmicrometers(4)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The unit of measurement for use calculating and relaying
         dimensional values for this input sub-unit.
                Additional information:
                Following is a table of paper sizes and
                dimensions for each paper size supported by
                the product:
                
                Size....................Inches(ten-thousandths)...Micrometers
                -----------------------------------------------------------------
                eUSExecutive............72500 x 105000............184150 x 266700
                eUSLetter...............85000 x 110000............215900 x 279400
                eUSLegal................85000 x 140000............215900 x 355600
                eFoolscap...............85000 x 130000............215900 x 330200
                eROC16K.................77500 x 107500............196850 x 273050
                eISOandJISA4............82677 x 116929............210000 x 297000
                eISOandJISA5............58286 x 82677.............148000 x 210000
                eJISB5..................71654 x 101181............182000 x 257000
                eIOSB5..................69300 x 98400.............176000 x 250000
                eJapanesePostcardSingle.39370 x 58267.............100000 x 148000
                eJapanesePostcardDouble.58267 x 78740.............148000 x 200000
                eMonarch................38750 x 75000.............98425  x 190500
                eCommercial10...........41250 x 95000.............104775 x 241300
                eInternationalDL........43307 x 86614.............110000 x 220000
                eInternationalC5........63780 x 90157.............162000 x 229000
                eInternationalB5........69291 x 98425.............176000 x 250000
                eCustom.................30000 x 140000(max).......76000 x 355600(max)"
::= { prtInputEntry 3 }


prtInputMediaDimFeedDirDeclared OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "This object provides the value of the declared dimension, in
        the feed direction, of the media that is (or, if empty, was or
        will be) in this input sub-unit.  The feed direction is the
        direction in which the media is fed on this sub-unit.  This
        dimension is measured in input sub-unit dimensional units
        (prtInputDimUnit).  If this input sub-unit can reliably sense
        this value, the value is sensed by the printer and may not be
        changed by management requests.  Otherwise, the value may be
        changed. The value (-1) means other and specifically means
        that this sub-unit places no restriction on this parameter.
        The value (-2) indicates unknown.
                Additional information:
                The default values assume the trays are
                configured for letter size paper.  For tray 1 the value is
                the dimension for the media size currently declared.
                
                Valid values are 50000 to 140000 if prtInputDimUnit is
                ePtenThousandthsOfInches and 127000 to 355600 if
                prtInputDimUnit is ePmicrometers."
::= { prtInputEntry 4 }


prtInputMediaDimXFeedDirDeclared OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "This object provides the value of the declared dimension, in
        the cross feed direction, of the media that is (or, if empty,
        was or will be) in this input sub-unit.  The cross  feed
        direction is ninety degrees relative to the feed direction
        associated with this sub-unit. This dimension is measured in
        input sub-unit dimensional units (prtInputDimUnit).  If this
        input sub-unit can reliably sense this value, the value is
        sensed by the printer and may not be changed by management
        requests. Otherwise, the value may be changed. The value (-1)
        means other and specifically means that this sub-unit places
        no restriction on this parameter. The value (-2) indicates
        unknown.
                Additional information:
                The default values assume the trays are
                configured for letter size paper.  For trays 1 & 2, the value
                is the dimension for the media size currently declared.
                
                Valid values are 30000 to 85000 if prtInputDimUnit is
                ePtenThousandthsOfInches and 76000 to 216000 if
                prtInputDimUnit is ePmicrometers.  The minimum
                value for tray 2 is 72500 (tenthousandsinch)
                and 191000(micrometers)."
::= { prtInputEntry 5 }


prtInputMediaDimFeedDirChosen OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The printer will act as if media of the chosen dimension (in
        the feed direction) is present in this input source.  Note
        that this value will be used even if the input tray is empty.
        Feed dimension measurements are taken relative to the feed
        direction associated with that sub-unit and are in input sub-unit
        dimensional units (MediaUnit). If the printer supports the
        declared dimension, the granted dimension is the same as
        the declared dimension. If not, the granted dimension is
        set to the closest dimension that the printer supports
        when the declared dimension is set. The value (-1) means
        other and specifically indicates that this sub-unit
        places no restriction on this parameter. The value (-2)
        indicates unknown.
                Additional information:
                The default value assumes the trays are configured
                for letter size paper.  The objects for the trays
                return the value of the media size for which the trays
                are currently configured because it cannot sense what size
                media they contain."
::= { prtInputEntry 6 }


prtInputMediaDimXFeedDirChosen OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The printer will act as if media of the chosen dimension (in
        the cross feed direction) is present in this input source.
        Note that this value will be used even if the input tray is
        empty.  The cross feed direction is ninety degrees relative
        to the feed direction associated with this sub-unit. This
        dimension is measured in input sub-unit dimensional units
        (MediaUnit).  If the printer supports the declared
        dimension, the granted dimension is the same as the
        declared dimension. If not, the granted dimension is set
        to the closest dimension that the printer supports when
        the declared dimension is set. The value (-1) means other
        and specifically indicates that this sub-unit places no
        restriction on this parameter.  The value (-2) indicates
        unknown.
                Additional information:
                The default value assumes the trays are configured
                for letter size paper.  The object for the trays
                return the value of the media size for which the trays
                are currently configured because it cannot sense what size
                media it contains."
::= { prtInputEntry 7 }


prtInputCapacityUnit OBJECT-TYPE
    SYNTAX      INTEGER {
                          ePsheets(8)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The unit of measurement for use in calculating and relaying
        capacity values for this input sub-unit.
                Additional information:
                A sheet is a single piece of 20 pound paper. "
::= { prtInputEntry 8 }


prtInputMaxCapacity OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The maximum capacity of the input sub-unit in input
        sub-unit capacity units (PrtCapacityUnitTC).  There is no
        convention associated with the media itself so this value
        reflects claimed capacity. If this input sub-unit can
        reliably sense this value, the value is sensed by the
        printer and may not be changed by management requests;
        otherwise, the value may be written (by a Remote
        Control Panel or a Management Application).
        The value (-1) means other and specifically
        indicates that the sub-unit places no restrictions
        on this parameter.  The value (-2) means unknown.
                Additional information:
                This is specified assuming 20 pound paper for
                the paper trays."
::= { prtInputEntry 9 }


prtInputCurrentLevel OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The current capacity of the input sub-unit in input
        sub-unit capacity units (PrtCapacityUnitTC). If this input
        sub-unit can reliably sense this value, the value is
        sensed by the printer and may not be changed by
        management requests; otherwise, the value may
        be written (by a Remote Contol Panel or a
        Management Application).  The value (-1) means other and
        specifically indicates that the sub-unit places no
        restrictions on this parameter. The value (-2) means unknown.
        The value (-3) means that the printer knows that at least one
        unit remains.
                Additional information:
                The product can only detect
                empty/not empty in its trays.  It returns -3 for not empty
                and -2 (unknown) for any other condition (e.g.  tray is empty
                or tray is removed)."
::= { prtInputEntry 10 }


prtInputStatus OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The current status of this input sub-unit.
                Additional information:
                The default value assumes that media is loaded
                in the tray.  When there is not media loaded in the tray it
                returns 9 instead of 0 (the default).
                
                Default - 0 (Available and Idle)
                paper motion - 6 (Available and Busy)
                paper out in this tray - 9 (Non-Critical Alert(8) + Unavailable and OnRequest(1))
                paper mount in this tray - 48 (Critical Alert (16) + OffLine (32))
                manual feed prompt (PaperMount) - 48 (Critical Alert (16) + OffLine (32))"
::= { prtInputEntry 11 }


prtInputMediaName OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(0..63))
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "A description of the media contained in this input sub-unit;
        This description is intended for display to a human operator.
        This description is not processed by the printer.  It is used
        to provide information not expressible in terms of the other
        media attributes (e.g. prtInputMediaDimFeedDirChosen,
        prtInputMediaDimXFeedDirChosen, prtInputMediaWeight,
        prtInputMediaType). An example would be `legal tender bond
        paper'.
                Additional information:
                The product supports the
                concept of named media types. The values for this
                			object will always match one of the MEDIAn-NAME objects."
::= { prtInputEntry 12 }


prtInputName OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(0..63))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The name assigned to this input sub-unit."
::= { prtInputEntry 13 }


prtInputVendorName OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(0..63))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The vendor name of this input sub-unit."
::= { prtInputEntry 14 }


prtInputModel OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(0..63))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The model name of this input sub-unit.
                Additional information:
                The product does not specify model
                names for the input trays."
::= { prtInputEntry 15 }


prtInputVersion OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(0..63))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The version of this input sub-unit.
                Additional information:
                The product does not specify version
                numbers for the input trays."
::= { prtInputEntry 16 }


prtInputSerialNumber OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(0..63))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The serial number assigned to this input sub-unit.
                Additional information:
                The product does not specify serial
                numbers for the input trays."
::= { prtInputEntry 17 }


prtInputDescription OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(0..255))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "A free-form text description of this input
        sub-unit in the localization specified by
        prtGeneralCurrentLocalization."
::= { prtInputEntry 18 }


prtInputSecurity OBJECT-TYPE
    SYNTAX      INTEGER {
                          ePother(1),
                          ePon(3),
                          ePoff(4),
                          ePnotPresent(5)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Indicates if this input sub-unit has some security
        associated with it.
                Additional information:
                No security mechanism provided."
::= { prtInputEntry 19 }


prtOutputType OBJECT-TYPE
    SYNTAX      INTEGER {
                          ePother(1),
                          ePunknown(2),
                          ePremovableBin(3),
                          ePunRemovableBin(4),
                          ePcontinuousRollDevice(5),
                          ePmailBox(6),
                          ePcontinousFanFold(7)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The type of technology supported by this output sub-unit.
                Additional information:
                The product has only one output bin, a
                face-down bin located at the top of the printer."
::= { prtOutputEntry 2 }


prtOutputCapacityUnit OBJECT-TYPE
    SYNTAX      INTEGER {
                          ePtenThousandthsOfInches(3),
                          ePmicrometers(4),
                          ePsheets(8),
                          ePfeet(16),
                          ePmeters(17)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The unit of measurement for use in calculating and relaying
        capacity values for this output sub-unit.
                Additional information:
                A sheet is a single piece of 20 pound paper."
::= { prtOutputEntry 3 }


prtOutputMaxCapacity OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The maximum capacity of this output sub-unit in output
        sub-unit capacity units (PrtCapacityUnitTC). There is no
        convention associated with the media itself so this value
        essentially reflects claimed capacity. If this output
        sub-unit can reliably sense this value, the value is
        sensed by the printer and may not be changed by management
        requests; otherwise, the value may be written
        (by a Remote Control Panel or a Management Application).
        The value (-1) means other and specifically indicates
        that the sub-unit places no restrictions on this parameter.
        The value (-2) means unknown.
                Additional information:
                Note:  The product cannot sense how
                much is in the output bin.  The output bin can hold 125
                sheets."
::= { prtOutputEntry 4 }


prtOutputRemainingCapacity OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The remaining capacity of the possible output sub-unit
        capacity in output sub-unit capacity units (PrtCapacityUnitTC)
        of this output sub-unit. If this output sub-unit can
        reliably sense this value, the value is sensed by the
        printer and may not be modified by management requests;
        otherwise, the value may be written (by
        a Remote Control Panel or a Management
        Application).  The value (-1) means other and
        specifically indicates that the sub-unit places no
        restrictions on this parameter.  The value (-2) means
        unknown.  The value (-3) means that the printer knows that
        there remains capacity for at least one unit.
                Additional information:
                The product does not have any sensing
                on the output bin, so it will always report unknown (-2).
                Note that for the products, this object is read-only
                because any values written by a Remote Control Panel or a
                Management Application would be unreliable."
::= { prtOutputEntry 5 }


prtOutputStatus OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The current status of this output sub-unit.
                Additional information:
                The product cannot sense the output
                tray so this object will always return 5 (Unknown Status)."
::= { prtOutputEntry 6 }


prtMarkerMarkTech OBJECT-TYPE
    SYNTAX      INTEGER {
                          ePelectrophotographicLaser(4)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The type of marking technology used for this marking sub-unit."
::= { prtMarkerEntry 2 }


prtMarkerCounterUnit OBJECT-TYPE
    SYNTAX      INTEGER {
                          ePimpressions(7)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The unit that will be used by the printer when reporting
        counter values for this marking sub-unit.  The
        time units of measure are provided for a device like a
        strip recorder that does not or cannot track the physical
        dimensions of the media and does not use characters,
        lines or sheets.
                Additional information:
                Since the product keeps track of pages
                printed, the counter unit will be defined as ePimpressions
                which would be like saying pages printed.  (The term
                'impressions' is used instead of 'pages' to avoid confusion
                between 'sheets' and 'pages' on a duplexing printer.)"
::= { prtMarkerEntry 3 }


prtMarkerLifeCount OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The count of the number of units of measure counted during
        the life of printer using units of measure as specified by
        prtMarkerCounterUnit.
                Additional information:
                In the product, the total engine page
                count is kept in NVRAM, however the NVRAM value is only
                updated every 10 impressions.
                
                NOTE:  The value returned by this OID will be incremented
                every page but if power is lost between NVRAM updates, up to
                9 impressions of the page count may be lost.  The counter
                will be reset to zero after 999999 pages.
                
                The page count is incremented when a sheet of media is pulled
                from an input tray."
::= { prtMarkerEntry 4 }


prtMarkerPowerOnCount OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The count of the number of units of measure counted since the
        equipment was most recently powered on using units of measure as
        specified by prtMarkerCounterUnit."
::= { prtMarkerEntry 5 }


prtMarkerProcessColorants OBJECT-TYPE
    SYNTAX      INTEGER(0..65535)
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The number of process colors supported by this marker.  A
        process color of 1 implies monochrome.  The value of this
        object and prtMarkerSpotColorants cannot both be 0.  The value of
        prtMarkerProcessColorants must be 0 or greater."
::= { prtMarkerEntry 6 }


prtMarkerSpotColorants OBJECT-TYPE
    SYNTAX      INTEGER(0..65535)
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The number of spot colors supported by this marker.  The
        value of this object and prtMarkerProcessColorants cannot
        both be 0.  Must be 0 or greater."
::= { prtMarkerEntry 7 }


prtMarkerAddressabilityUnit OBJECT-TYPE
    SYNTAX      INTEGER {
                          ePtenThousandthsOfInches(3)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The unit of measure of distances, as applied to the marker's
         resolution.
                Additional information:
                This will always be ePtenThousandthsOfInches, no
                matter what COLD-RESET-MEDIA-SIZE is because we are talking
                about resolution and toner addressability, which is always
                dpi."
::= { prtMarkerEntry 8 }


prtMarkerAddressabilityFeedDir OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The maximum number of addressable marking positions in the feed
        direction per 10000 units of measure specified by
        prtMarkerAddressabilityUnit.  A value of (-1) implies 'other' or
        'infinite' while a value of (-2) implies 'unknown'.
                Additional information:
                Use this object to specify resolution.  The 
                product supports 600 dots  per inch."
::= { prtMarkerEntry 9 }


prtMarkerAddressabilityXFeedDir OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The maximum number of addressable marking positions in the cross
        feed direction in 10000 units of measure specified by
        prtMarkerAddressabilityUnit.  A value of (-1) implies 'other' or
        'infinite' while a value of (-2) implies 'unknown'.
                Additional information:
                Use this object to specify resolution.  The 
                product supports 600 dots per inch."
::= { prtMarkerEntry 10 }


prtMarkerNorthMargin OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The margin, in units identified by prtMarkerAddressabilityUnit,
        from the leading edge of the medium as the medium flows
        through the marking engine with the side to be imaged
        facing the observer. The leading edge is the North edge
        and the other edges are defined by the normal compass
        layout of  directions with the compass facing the
        observer.  Printing within the area bounded by all four
        margins is guaranteed for all interpreters.   The value
        (-2) means unknown."
::= { prtMarkerEntry 11 }


prtMarkerSouthMargin OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The margin from the South edge  (see prtMarkerNorthMargin)
        of the medium in units identified by
        prtMarkerAddressabilityUnit.  Printing within the area bounded by
        all four margins  is guaranteed for all interpreters.
        The value (-2) means unknown."
::= { prtMarkerEntry 12 }


prtMarkerWestMargin OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The margin from the West edge (see prtMarkerNorthMargin) of the
        medium in units identified by prtMarkerAddressabilityUnit.
        Printing within the area bounded by all four margins is
        guaranteed for all interpreters.   The value (-2) means
        unknown."
::= { prtMarkerEntry 13 }


prtMarkerEastMargin OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The margin from the East edge (see prtMarkerNorthMargin) of the
        medium in units identified by prtMarkerAddressabilityUnit.
        Printing within the area bounded by all four margins is
        guaranteed for all interpreters. The value (-2) means
        unknown."
::= { prtMarkerEntry 14 }


prtMarkerStatus OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The current status of this marker sub-unit.
                Additional information:
                The default value assumes the printer is idle
                and has no malfunctions.           
                
                Default - 0 (Available and Idle)
                no toner cartridge - 51 (UnAvailable because Broken (3) + Critical Alert (16) + OffLine (32))"
::= { prtMarkerEntry 15 }


prtMarkerSuppliesMarkerIndex OBJECT-TYPE
    SYNTAX      INTEGER(0..65535)
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The value of prtMarkerIndex corresponding to the
        marking sub-unit with which this marker supply
        sub-unit is associated."
::= { prtMarkerSuppliesEntry 2 }


prtMarkerSuppliesColorantIndex OBJECT-TYPE
    SYNTAX      INTEGER(0..65535)
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The value of prtMarkerColorantIndex
        corresponding to the colorant with which this
        marker supply sub-unit is associated.  This value
        shall be 0 if there is no colorant table."
::= { prtMarkerSuppliesEntry 3 }


prtMarkerSuppliesClass OBJECT-TYPE
    SYNTAX      INTEGER {
                          ePother(1),
                          ePsupplyThatIsConsumed(3),
                          ePreceptacleThatIsFilled(4)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Indicates whether this supply entity represents a supply
        that is consumed or a receptacle that is filled."
::= { prtMarkerSuppliesEntry 4 }


prtMarkerSuppliesType OBJECT-TYPE
    SYNTAX      INTEGER {
                          ePtoner(3),
                          ePtransferUnit(20),
                          ePtonerCartridge(21),
                          ePfuser(15),
                          ePdeveloper(10),
                          ePfuserCleaingPad(19),
                          ePopc(9)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The type of this supply."
::= { prtMarkerSuppliesEntry 5 }


prtMarkerSuppliesDescription OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(0..255))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The description of this supply container/receptacle in the
        localization specified by prtGeneralCurrentLocalization.
                Additional information:
                "
::= { prtMarkerSuppliesEntry 6 }


prtMarkerSuppliesSupplyUnit OBJECT-TYPE
    SYNTAX      INTEGER {
                          ePtenThousandthsOfInches(3),
                          ePmicrometers(4),
                          ePimpressions(7),
                          ePsheets(8),
                          ePthousandthsOfOunces(12),
                          ePhours(11),
                          ePtenthsOfGrams(13),
                          ePhundrethsOfFluidOunces(14),
                          ePtenthsOfMilliliters(15),
                          ePfeet(16),
                          ePmeters(17),
                          ePpercent(19)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Unit of measure of this marker supply container/receptacle."
::= { prtMarkerSuppliesEntry 7 }


prtMarkerSuppliesMaxCapacity OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The maximum capacity of this supply container/receptacle
        expressed in prtMarkerSuppliesSupplyUnit. If this supply
        container/receptacle can reliably sense this value, the
        value is reported by the printer and is read-only;
        otherwise, the value may be written (by a Remote Control
        Panel or a Management Application). The value (-1) means
        other and specifically indicates that the sub-unit places
        no restrictions on this parameter. The value (-2) means
        unknown.
                Additional information:
                This object reports the maximum capacity for the supply
                against which the level is reported."
::= { prtMarkerSuppliesEntry 8 }


prtMarkerSuppliesLevel OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The current level if this supply is a container; the
        remaining space if this supply is a receptacle. If this
        supply container/receptacle can reliably sense this
        value, the value is reported by the printer and is
        read-only; otherwise, the value may be written (by a
        Remote Control Panel or a Management Application). The
        value (-1) means other and specifically indicates that
        the sub-unit places no restrictions on this parameter.
        The value (-2) means unknown.  A value of (-3) means that the
        printer knows that there is some supply/remaining space,
        respectively.
                Additional information:
                Print Cartridges measure life based on the three
                components: toner, developer and drum.  These Print
                Cartridge object (1) report the lowest of these
                three factors. Print Cartridges that are not
                installed will return a value of 100."
::= { prtMarkerSuppliesEntry 9 }


prtMarkerColorantMarkerIndex OBJECT-TYPE
    SYNTAX      INTEGER(0..65535)
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The value of prtMarkerIndex corresponding to the
        marker sub-unit with which this colorant entry is
        associated."
::= { prtMarkerColorantEntry 2 }


prtMarkerColorantRole OBJECT-TYPE
    SYNTAX      INTEGER {
                          ePother(1),
                          ePprocess(3),
                          ePspot(4)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The role played by this colorant."
::= { prtMarkerColorantEntry 3 }


prtMarkerColorantValue OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(0..255))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The name of the color of this
        colorant using standardized string names from ISO 10175 (DPA)
        and ISO 10180 (SPDL) which are:
          other
          unknown
          white
          red
          green
          blue
          cyan
          magenta
          yellow
          black
        Implementors may add additional string values. The naming
        conventions in ISO 9070 are recommended in order to avoid
        potential name clashes.
                Additional information:
                "
::= { prtMarkerColorantEntry 4 }


prtMarkerColorantTonality OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The distinct levels of tonality realizable by a marking
        sub-unit when using this colorant.  This value does not
        include the number of levels of tonal difference that an
        interpreter can obtain by techniques such as half toning.
        This value must be at least 2."
::= { prtMarkerColorantEntry 5 }


prtMediaPathMaxSpeedPrintUnit OBJECT-TYPE
    SYNTAX      INTEGER {
                          ePimpressionsPerHour(7)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The unit of measure used in specifying the speed of all media
        paths in the printer.
                Additional information:
                ePimpressionsPerHour is the value that will
                always be returned for this object.  (Print Speed is measured
                in pages-per-minute (impressions per minute), so
                ePimpressionsPerHour is a natural extension.)"
::= { prtMediaPathEntry 2 }


prtMediaPathMediaSizeUnit OBJECT-TYPE
    SYNTAX      INTEGER {
                          ePtenThousandthsOfInches(3),
                          ePmicrometers(4)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The units of measure of media size for use in calculating and
        relaying dimensional values for all media paths in the printer."
::= { prtMediaPathEntry 3 }


prtMediaPathMaxSpeed OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The maximum printing speed of this media path expressed in
        prtMediaPathMaxSpeedUnit's.  A value of (-1) implies
        'other'.
                Additional information:
                The page size for this performance is 8.5 x 11. For
                	    the product, this value is (12ppm * 60)."
::= { prtMediaPathEntry 4 }


prtMediaPathMaxMediaFeedDir OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The maximum physical media size in the feed direction of this
        media path expressed in units of measure specified by
        PrtMediaPathMediaSizeUnit.  A value of (-1) implies 'unlimited',
        a value of (-2) implies 'unknown'.
                Additional information:
                The value returned by this object depends on the
                value of prtMediaPathMediaSizeUnit.  It is 140000 if
                prtInputDimUnit is ePtenThousandthsOfInches or 355600 if
                prtInputDimUnit is ePmicrometers.  (140000 is the value
                arrived at because legal paper is the longest allowable on
                the product.)"
::= { prtMediaPathEntry 5 }


prtMediaPathMaxMediaXFeedDir OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The maximum physical media size across the feed direction of
        this media path expressed in units of measure specified by
        prtMediaPathMediaSizeUnit.  A value of (-2) implies 'unknown'.
                Additional information:
                The value returned by this object depends on the
                value of prtMediaPathMediaSizeUnit.  It is 85000 if
                prtInputDimUnit is ePtenThousandthsOfInches or 216000 if
                prtInputDimUnit is ePmicrometers."
::= { prtMediaPathEntry 6 }


prtMediaPathMinMediaFeedDir OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The minimum physical media size in the feed direction of this
        media path expressed in units of measure specified by
        prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'.
                Additional information:
                The value returned by this object depends on the
                value of prtMediaPathMediaSizeUnit.  It is 50000 if
                prtInputDimUnit is ePtenThousandthsOfInches or 127000 if
                prtInputDimUnit is ePmicrometers."
::= { prtMediaPathEntry 7 }


prtMediaPathMinMediaXFeedDir OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The minimum physical media size across the feed direction of
        this media path expressed in units of measure specified by
        prtMediaPathMediaSizeUnit.  A value of (-2) implies 'unknown'.
                Additional information:
                The value returned by this object depends on the
                value of prtMediaPathMediaSizeUnit.  It is 30000 if
                prtInputDimUnit is ePtenThousandthsOfInches or 76200 if
                prtInputDimUnit is ePmicrometers.  This size corresponds to a
                Monarch envelope.  "
::= { prtMediaPathEntry 8 }


prtMediaPathType OBJECT-TYPE
    SYNTAX      INTEGER {
                          ePlongEdgeBindingDuplex(3),
                          ePsimplex(5)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The type of the media path for this media path.
                Additional information:
                This object describes how many paths there are
                through the engine disregarding the paper source (tray 1, 2,
                or 3)."
::= { prtMediaPathEntry 9 }


prtMediaPathDescription OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(0..255))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The manufacturer-provided description of this media path in
        the localization specified by prtGeneralCurrentLocalization."
::= { prtMediaPathEntry 10 }


prtMediaPathStatus OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The current status of this media path.
                Additional information:
                The default values assume the printer is idle.
                
                Default - 0 (Available and Idle)
                paper motion - 6 (Available and Busy)
                paper out in all trays - 9 (Non-Critical Alert(8) + Unavailable and OnRequest(1))
                paper mount (any tray) - 0 (Available and Idle)
                manual feed prompt (PaperMount) - 48 (Critical Alert (16) + OffLine (32))"
::= { prtMediaPathEntry 11 }


prtInterpreterLangFamily OBJECT-TYPE
    SYNTAX      INTEGER {
                          ePother(1),
                          ePlangPCL(3),
                          ePlangPJL(5),
                          ePlangPS(6),
                          ePlangAutomatic(37),
                          ePlangPCLXL(47)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The family name of a Page Description Language (PDL) or
        control language which this interpreter in the printer can
		interpret or emulate.
                Additional information:
                ePlangAutomatic refers to the 'super-language'
                made available by implicit language switching."
::= { prtInterpreterEntry 2 }


prtInterpreterLangLevel OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(0..31))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The level of the language which this interpreter is
        interpreting or emulating.  This might contain a value like
        '5e' for an interpreter which is emulating level 5e of the PCL
        language.  It might contain '2' for an interpreter which is
        emulating level 2 of the PostScript language.  Similarly it
        might contain '2' for an interpreter which is emulating level
        2 of the HPGL language."
::= { prtInterpreterEntry 3 }


prtInterpreterLangVersion OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(0..31))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The date code or version of the language which this interpreter
        is interpreting or emulating.
                Additional information:
                These values are derived from the dateCode field
                of the personality entities.  (ePlangautomatic uses the PJL
                dateCode.)  For PostScript, this is more detailed revision
                information."
::= { prtInterpreterEntry 4 }


prtInterpreterDescription OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(0..255))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "A string to identify this interpreter in the localization
        specified by prtGeneralCurrentLocalization as opposed to the
        language which is being interpreted.  It is anticipated that
        this string will allow manufacturers to unambiguously identify
        their interpreters.
                Additional information:
                None of these strings are localized."
::= { prtInterpreterEntry 5 }


prtInterpreterVersion OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(0..31))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The date code, version number, or other product specific
        information tied to this interpreter.  This value is
        associated with the interpreter, rather than with the version
        of the language which is being interpreted or emulated.
                Additional information:
                Same as prtInterpreterLangVersion."
::= { prtInterpreterEntry 6 }


prtInterpreterDefaultOrientation OBJECT-TYPE
    SYNTAX      INTEGER {
                          ePportrait(3),
                          ePlandscape(4)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The current orientation default for this interpreter.  This
        value may be overridden for a particular job (e.g., by a
        command in the input data stream).
                Additional information:
                Interpreters 1 and 2 ignore the value of this
                object.
                
                The values for PCL and PostScript are either ePportrait or
                ePlandscape; attempting to set them to a different value will
                cause <badValue> to be returned.
                Setting this object for one interpreter will change it for
                all installed interpreters."
::= { prtInterpreterEntry 7 }


prtInterpreterFeedAddressability OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The maximum interpreter addressability in the feed
        direction in 10000 prtMarkerAddressabilityUnits (see
        prtMarkerAddressabilityFeedDir ) for this interpreter.
        The value (-1) means other and specifically indicates
        that the sub-unit places no restrictions on this parameter."
::= { prtInterpreterEntry 8 }


prtInterpreterXFeedAddressability OBJECT-TYPE
    SYNTAX      INTEGER
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The maximum interpreter addressability in the cross feed
        direction in 10000 prtMarkerAddressabilityUnits (see
        prtMarkerAddressabilityXFeedDir) for this interpreter.
        The value (-1) means other and specifically indicates
        that the sub-unit places no restrictions on this
        parameter."
::= { prtInterpreterEntry 9 }


prtInterpreterDefaultCharSetIn OBJECT-TYPE
    SYNTAX      INTEGER {
                          ePother(1),
                          ePcsASCII(3),
                          ePcsISOLatin1(4),
                          ePcsISOLatin2(5),
                          ePcsISOLatin5(12),
                          ePcsISOLatin6(13),
                          ePcsISOLatin9(2090),
                          ePcsISO4UnitedKingdom(20),
                          ePcsISO11SwedishforNames(21),
                          ePcsISO15Italian(22),
                          ePcsISO17Spanish(23),
                          ePcsISO21German(24),
                          ePcsISO60DanishNorwegian(25),
                          ePcsISO69French(26),
                          ePcsUnicodeIBM2039(1004),
                          ePcsWindows30Latin1(2000),
                          ePcsWindows31Latin1(2001),
                          ePcsWindows31Latin2(2002),
                          ePcsWindows31Latin5(2003),
                          ePcsHPRoman8(2004),
                          ePcsAdobeStandardEncoding(2005),
                          ePcsPC850Multilingual(2009),
                          ePcsPC858Multilingual(2089),
                          ePcsPCp852(2010),
                          ePcsPC8CodePage437(2011),
                          ePcsPC8DNDanishNorwegian(2012),
                          ePcsHPPC8Turkish(2014),
                          ePcsHPLegal(2017),
                          ePcsHPDeskTop(2021),
                          ePcsMacintosh(2027),
                          ePcsPC77Baltic(2087),
                          ePcsWindows1257Baltic(2257)
		   }
    ACCESS      read-write
    STATUS      optional
       DESCRIPTION "The default coded character set for input octets
        encountered outside a context in which the Page
        Description Language established the interpretation
        of the octets. (Input octets are presented to the
        interpreter through a path defined in the channel group.)
        This value shall be (2) if there is no default.
                Additional information:
                ePcsAdobeStandardEncoding is the same as PSText(10J).
                
                The object corresponding to PCL has read-write access;
                all others are read-only.
                
                Note: To determine which languages correspond to which subarrays refer
                to the object prtInterpreterLangFamily.
                
                The above list corresponds to the following symbol sets as they appear
                on the Control Panel:
                
                ePother( 1) - used if designated coded char. set not in list
                ePcsASCII( 3) - ISO-6
                ePcsISOLatin1( 4) - ISO L1
                ePcsISOLatin2( 5) - IS L2
                ePcsISOLatin5( 12) - ISO L5
                ePcsISOLatin6( 13) - ISO L6
                ePcsISOLatin9( 2090) - ISO L9
                ePcsISO4UnitedKingdom( 20) - ISO-4
                ePcsISO11SwedishforNames( 21) - ISO-11
                ePcsISO15Italian( 22) - ISO-15
                ePcsISO17Spanish( 23) - ISO-17
                ePcsISO21German( 24) - ISO-21
                ePcsISO60DanishNorwegian( 25) - ISO-60
                ePcsISO69French( 26) - ISO-69
                ePcsUnicodeIBM2039(1004) - PC-1004
                ePcsWindows30Latin1( 2000) - WIN 3.0
                ePcsWindows31Latin1( 2001) - WIN L1
                ePcsWindows31Latin2( 2002) - WIN L2
                ePcsWindows31Latin5( 2003) - WIN L5
                ePcsHPRoman8( 2004) - ROMAN-8
                ePcsAdobeStandardEncoding( 2005) - PS TEXT
                ePcsPC850Multilingual( 2009) - PC-850
                ePcsPC858Multilingual( 2089) - PC-858
                ePcsPCp852( 2010) - PC-852
                ePcsPC8CodePage437( 2011) - PC-8
                ePcsPC8DNDanishNorwegian( 2012) - PC-8DN
                ePcsHPPC8Turkish( 2014) - PC-8 TK
                ePcsHPLegal( 2017) - LEGAL
                ePcsHPDeskTop( 2021) - DESKTOP
                ePcsMacintosh( 2027) - MC TEXT
                ePcsPC77Baltic( 2087) - PC-775
                ePcsWindows1257Baltic( 2257) - WINBALT"
::= { prtInterpreterEntry 10 }


prtInterpreterDefaultCharSetOut OBJECT-TYPE
    SYNTAX      INTEGER {
                          ePcsNoDefault(2),
                          ePcsASCII(3),
                          ePcsHPRoman8(2004),
                          ePcsAdobeStandardEncoding(2005)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The default character set for data coming from this interpreter
        through the printer's output channel (i.e. the 'backchannel'). 
        This value shall be (2) if there is no default."
::= { prtInterpreterEntry 11 }


prtInterpreterTwoWay OBJECT-TYPE
    SYNTAX      INTEGER {
                          ePyes(3),
                          ePno(4)
		   }
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "Indicates whether or not this interpreter returns information
        back to the host."
::= { prtInterpreterEntry 12 }


prtConsoleDisplayBufferText OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE(0..255))
    ACCESS      read-only
    STATUS      optional
       DESCRIPTION "The content of a line in the logical display buffer of
        the operator's console of the printer.  When a write
        operation occurs, normally a critical message, to one of
        the LineText strings, the agent should make that line
        displayable if a physical display is present.  Writing
        a zero length string clears the line.  It is an
        implementation-specific matter as to whether the agent allows
        a line to be overwritten before it has been cleared.
        Printer generated strings shall be in the localization
        specified by prtConsoleLocalization.  Management Application
        generated strings should be localized by the Management
        Application.
                Additional information:
                In the case of a 2-line display message,
                prtConsoleDisplayBufferText.1 maps to the first
                line and prtConsoleDisplayBufferText.2 maps to
                the second.  In the case of a 1-line display
                message, prtConsoleDisplayBufferText.1 maps to
                the first line and prtConsoleDisplayBufferText.2
                return NULL."
::= { prtConsoleDisplayBufferEntry 2 }


END