HP-ICF-FTRCO DEFINITIONS ::= BEGIN

   IMPORTS
      OBJECT-TYPE, MODULE-IDENTITY, Integer32
         FROM SNMPv2-SMI
      MODULE-COMPLIANCE, OBJECT-GROUP
         FROM SNMPv2-CONF
      SnmpAdminString
         FROM SNMP-FRAMEWORK-MIB
      RowStatus, 
      TruthValue,
      DateAndTime,
      TEXTUAL-CONVENTION
         FROM SNMPv2-TC
      PortList
         FROM Q-BRIDGE-MIB 
      hpSwitch
         FROM HP-ICF-OID;

   hpicfFtrCo MODULE-IDENTITY
      LAST-UPDATED "201006010000Z" -- June 1, 2010
      ORGANIZATION "HP Networking"
      CONTACT-INFO "Hewlett Packard Company
                    8000 Foothills Blvd.
                    Roseville, CA 95747"
      DESCRIPTION "This MIB module manages Application 
                   Coordination Restriction Policies"

      REVISION     "201006010000Z" -- June 1, 2010
      DESCRIPTION  "Added aclPermitLogging."

      REVISION     "200908280002Z" -- Aug 28, 2009
      DESCRIPTION  "Initial revision."

      ::= { hpSwitch 46 }


-- -------------------------------------------------------------
-- Textual Conventions
-- -------------------------------------------------------------

   VidList ::= TEXTUAL-CONVENTION
      DISPLAY-HINT "512x"
      STATUS      current
      DESCRIPTION 
         "Each octet within this value specifies a set of eight
         VlanIIndex (VID), with the first octet specifying VIDs 1
         through 8, the second octet specifying VIDs 9 through 16,
         etc.  Within each octet, the most significant bit represents
         the lowest numbered VID, and the least significant bit
         represents the highest numbered VID.  Thus, each VID
         is represented by a single bit within the value of this
         object.  If that bit has a value of 1 then that VID is
         included in the set of VIDs; the VID is not included if its
         bit has a value of 0.  This list represents the entire
         range of VlanIndex values defined in the scope of IEEE
         802.1Q."
      SYNTAX      OCTET STRING (SIZE (512))

   IndexName ::= TEXTUAL-CONVENTION
      DISPLAY-HINT "32a"
      STATUS      current
      DESCRIPTION
         "This object is valid when used as an index - an IndexName
         is similar to a DisplayString, except that it does allow
         a tilde ('~') and spaces within ts definition.  Otherwise
         it fully follows the textual-convention of the standard 
         DisplayString definition."
      SYNTAX      OCTET STRING (SIZE (0..32))


-- -------------------------------------------------------------
-- Start of MIB Objects
-- -------------------------------------------------------------

  hpicfFtrcoObjects OBJECT IDENTIFIER ::= { hpicfFtrCo 1 }

   hpFtrCoEntityTable OBJECT-TYPE
   SYNTAX      SEQUENCE OF HpFtrcoEntityEntry
   MAX-ACCESS  not-accessible
   STATUS      current
   DESCRIPTION
      "Table of all Entities setting restrictions, as set by some external
      entity.  Any restriction for an Entity can be deleted by deleting the 
      Entity name, by deleting a specific restriction, or by any expiration
      value.  Once an Entity name has been added to the table, it exist until
      the name has specifically been removed.  Entity rows also maintain the
      'next-index' value for any restriction table entry."
   ::= { hpicfFtrcoObjects 1 }

   hpFtrCoEntityEntry OBJECT-TYPE
      SYNTAX       HpFtrcoEntityEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
         "A row entry in the table for a specific entity user of the Feature
         Coordinator facility.  Entries in this table are created and removed
         dynamically.  An entity can add and remove a restriction regarding 
         some pre-defined facility in the switch and it will only be for a 
         specific Entity name.  If the Entity name is removed, so are all of
         its restrictions."
      INDEX       { hpFtrCoEntityName }
      ::= { hpFtrCoEntityTable 1 }

   HpFtrcoEntityEntry ::=
      SEQUENCE {
         hpFtrCoEntityName           IndexName,
         hpFtrCoRestrictNextIndex    Integer32,
         hpFtrCoEntityDate           DateAndTime,
         hpFtrCoEntityStatus         RowStatus
      }

   hpFtrCoEntityName OBJECT-TYPE
      SYNTAX      IndexName (SIZE(1..32))
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
         "An administratively assigned string, which may be used to identify 
         the unique owner of a set of restrictions."
      ::= { hpFtrCoEntityEntry 1 }

   hpFtrCoRestrictNextIndex OBJECT-TYPE
      SYNTAX      Integer32 (0..2147483647)
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION 
            "Is the next indexing parameter that allows multiple, like 
            restrictions.  It is has a default value of 1 and is incremented
            each time its index value is used.  This is an independent value
            and must be specified as the next added index (regardless of the
            restriction type).  In the event there is a collision due to a race
            with reading the current value, the 'losing' restriction is denied
            and the value should be re-read for a next attempt.  The value is
            always 1 whenever a new Entity record is created."
      DEFVAL { 1 }
      ::= { hpFtrCoEntityEntry 2 }

   hpFtrCoEntityDate OBJECT-TYPE
      SYNTAX      DateAndTime
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "This represents the switch's understanding of the current UTC time.
          It should be used when setting an restriction expiration 
          DateAndTime value.  Please note that this value is uniquely 
          determined each time the object is read (dynamic) and is 
          subject to changing when a change is made to the switch's
          configuration (e.g. setting the local time-zone)."
      ::= { hpFtrCoEntityEntry 3 }

   hpFtrCoEntityStatus OBJECT-TYPE
      SYNTAX      RowStatus
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
         "Administrative status of this Entity entry."
      ::= { hpFtrCoEntityEntry 4 }

   hpFtrCoRestrictionTable OBJECT-TYPE
   SYNTAX      SEQUENCE OF HpFtrCoRestrictEntry
   MAX-ACCESS  not-accessible
   STATUS      current
   DESCRIPTION
      "Table of all restrictions, set by an external entity.  The restrictions
      can be deleted by deleting the entity name or by the restriction 
      expiration value. Expiration policies are logically ORed so that any policy 
      expiration that is met causes the restriction to be removed."
   ::= { hpicfFtrcoObjects 2 }

   hpFtrCoRestrictEntry OBJECT-TYPE
      SYNTAX       HpFtrCoRestrictEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION
         "An entry in the table for a specific Entity user of the Feature 
         Coordinator facility.  Entries in this table are created and removed 
         dynamically.  An entity can add and remove a restriction to some 
         facility in the switch.  These entries can also expire, based on 
         entity specified criteria.  A restriction is never modified (all
         restrictions are only created or deleted).  If a value needs to be 
         modified, a new restriction could be added and then the old one 
         deleted (e.g. adding or removing an interface)."
      INDEX       { hpFtrCoEntityName, 
                    hpFtrCoRestrictId,
                    hpFtrCoRestrictIndex }
      ::= { hpFtrCoRestrictionTable 1 }

   HpFtrCoRestrictEntry ::=
      SEQUENCE {
         hpFtrCoRestrictId           INTEGER,
         hpFtrCoRestrictIndex        Integer32,
         hpFtrCoRestrictIdParm       Integer32,
         hpFtrCoRestrictStatus       RowStatus,
         hpFtrCoRestrictMessage      SnmpAdminString,
         hpFtrCoRestrictPorts        PortList,
         hpFtrCoRestrictVlans        VidList,
         hpFtrCoExpireSlot           Integer32,
         hpFtrCoExpireApplication    IndexName,
         hpFtrCoExpireVidDelete      Integer32,
         hpFtrCoExpireDate           DateAndTime,
         hpFtrCoExpireBoot           TruthValue
      }


   hpFtrCoRestrictId OBJECT-TYPE
      SYNTAX      INTEGER {
         vidIpConfig(1),
         vidDelete(2),
         portSecurity(3),
         portAcl(4),
         portSourcePortFilter(5),
         portMeshing(6),
         portLacp(7),
         distributedTrunk(8),
         portVirusThrottling(9),
         portSflow(10),
         portDhcpSnoop(11),
         portLoopDetection(12),
         portBpduPvstGuard(13),
         qinq(14),
         portQos(15),
         portRateLimit(16),
         portStaticMac(17),
         portIpLockdown(18),
         portIgmp(19),
         portMirrorDestination(20),
         portLinkConfig(21),
         portLldp(22),
         portKeepalive(23),
         aclPermitLogging(24)
      }
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
         "The Restriction enumeration (Id).  Expect this list to grow as are 
         more restrictions are developed (and needed)."
      ::= { hpFtrCoRestrictEntry 1}

   hpFtrCoRestrictIndex OBJECT-TYPE
      SYNTAX      Integer32 (0..2147483647)
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION 
         "An indexing parameter to allow multiple, like restrictions.  It is 
         created by the Entity portion of MIB and used for addressing an 
         individual restriction rule.  Any new restriction added to a
         restriction table must be equal to the current 'next-restriction'
         value."
      ::= { hpFtrCoRestrictEntry 2 }

   hpFtrCoRestrictIdParm OBJECT-TYPE
      SYNTAX      Integer32 (0..2147483647)
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION 
         "An optional parameter for the restriction enumeration."
      ::= { hpFtrCoRestrictEntry 3 }

   hpFtrCoRestrictStatus OBJECT-TYPE
      SYNTAX      RowStatus
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
         "Administrative status of this entry."
      ::= { hpFtrCoRestrictEntry 4 }

   hpFtrCoRestrictMessage OBJECT-TYPE
      SYNTAX      SnmpAdminString (SIZE (1..255))
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
         "An error message containing information about the restriction that 
         can be used by the caller, indicating the reason for this restriction 
         being in place.  It is occasionally referred to as a friendly error
         message.  SIZE reflects that a message must exist and that it has
         a maximum 'String' length of 255 character."
      ::= { hpFtrCoRestrictEntry 5 }

   hpFtrCoRestrictPorts OBJECT-TYPE
      SYNTAX      PortList
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION 
         "A list of ports, if applicable to the restriction."
      ::= { hpFtrCoRestrictEntry 6 }

   hpFtrCoRestrictVlans OBJECT-TYPE
      SYNTAX      VidList
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION 
         "A VidList of vlan IDs, if applicable to the restriction."
      ::= { hpFtrCoRestrictEntry 7 }

   hpFtrCoExpireSlot OBJECT-TYPE
      SYNTAX      Integer32 (0..2147483647)
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION 
         "Setting this value will cause this restriction to expire when 
         corresponding switch slot is signaled to be down.  Note, if the slot 
         never comes up, there will be no slot-down signal."
      ::= { hpFtrCoRestrictEntry 8 }

   hpFtrCoExpireApplication OBJECT-TYPE
      SYNTAX      IndexName (SIZE (0..32))
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION 
         "This setting will cause the restriction to expire whenever a signal 
         is received that this application-name has gone down."
        ::= { hpFtrCoRestrictEntry 9 }

   hpFtrCoExpireVidDelete OBJECT-TYPE
      SYNTAX      Integer32 (0..4096)
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION 
         "A signal indicating this VlanIndex has been deleted will cause this 
         restriction to expire.  The specified VID record must exist in the 
         switch configuration for this policy to be set.  NOTE: ExpireVidDelete
         is unused in this release; it is available, you can set it; but it is 
         totally ignored with current processing."

      ::= { hpFtrCoRestrictEntry 10 }

   hpFtrCoExpireDate OBJECT-TYPE
      SYNTAX      DateAndTime
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION 
         "This expiration event occurs whenever it is determined that the
          switch-time exceeds this setting.  The switches sw_time() represents
          the UTC time value (relative to Jan 1, 1990) used with this comparison
          (compare with sw_localtime).  NOTE: ExpireDate is unused in this release;
          it is available, you can set it; but it is totally ignored with current
          processing."
      ::= { hpFtrCoRestrictEntry 11 }

   hpFtrCoExpireBoot OBJECT-TYPE
      SYNTAX      TruthValue
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
         "When specified as 'true', this expiration event occurs whenever the 
          switch reboots.  It is a necessary expiration policy since all 
          restrictions are persistent and it is possible that we can have an 
          obsolete policy (slot-down) following a power-fail condition."
      DEFVAL      { false }
      ::= { hpFtrCoRestrictEntry 12 }


-- **********************************************************************
-- Conformance Information
-- **********************************************************************

    hpicfFtrCoConformance OBJECT IDENTIFIER ::= { hpicfFtrCo 2 }

    hpicfFtrCoCompliances  OBJECT IDENTIFIER ::= { hpicfFtrCoConformance 1 }
    hpicfFtrCoGroups       OBJECT IDENTIFIER ::= { hpicfFtrCoConformance 2 }

    hpicfFtrCoCompliance MODULE-COMPLIANCE
        STATUS      current
        DESCRIPTION "The compliance statement for HP switches
                    implementing the HP-ICF-FTRCO-MIB."
        MODULE
            MANDATORY-GROUPS { hpicfFtrCoGroup }
            GROUP       hpicfFtrCoGroup
            DESCRIPTION "Support for this group is required for HP switches
                        that implement Feature Coordinator."
        ::= { hpicfFtrCoCompliances 1 }

    hpicfFtrCoGroup OBJECT-GROUP
        OBJECTS     {
         hpFtrCoRestrictNextIndex,
         hpFtrCoEntityDate,
         hpFtrCoEntityStatus,
         hpFtrCoRestrictIdParm,
         hpFtrCoRestrictStatus,
         hpFtrCoRestrictMessage,
         hpFtrCoRestrictPorts,
         hpFtrCoRestrictVlans,
         hpFtrCoExpireSlot,
         hpFtrCoExpireApplication,
         hpFtrCoExpireVidDelete,
         hpFtrCoExpireDate,
         hpFtrCoExpireBoot
        }
        STATUS      current
        DESCRIPTION "A collection of HP proprietary objects to support
                    Feature Coordinator."
        ::= { hpicfFtrCoGroups 1 }


END