-- (C)  COPYRIGHT HEWLETT-PACKARD COMPANY 2000.
--
-- HP Color LaserJet 8550 Printer Specific MIB.
-- Hewlett-Packard Company Confidential
--
-- Hewlett-Packard makes no warranty of any kind with
-- regard to this manual, including, but not limited
-- to, the implied warranties of merchantability and
-- fitness for a particular purpose.  Hewlett Packard
-- shall not be held liable for errors contained herein
-- or direct, indirect, special, incidental, or
-- consequential damages in connection with the
-- furnishing, performance, or use of this material.
--
-- Generated on May 22, 2000.
--
-- Company names and product names mentioned herein may be
-- trademarks, and/or registered trademarks of their respective
-- companies.
--
-- This MIB describes all the printer model specific
-- objects supported by the HP LaserJet 8550 printer
-- when networked connected using a JetDirect print
-- server.
--
-- For interal and external use.
--
-- This MIB describes all the printer model specific
-- objects supported by the HP Color LaserJet 8550 printer
-- when networked connected using a JetDirect print
-- server.
--
-- The following MIB also contain objects supported
-- by a JetDirect connected HP Color LaserJet 8550 printer:
--
-- rfc 1213 MIB II
--
-- This MIB complies with the following RFCs:
--
-- rfc 1157 Simple Network Management Protocol
-- rfc 1155 Structure of Management Information
--
-- Notes:
--
-- 1) Proprietary Objects containing a string which are defined in this MIB use the
--    first two bytes to hold the symbol set used to encode the string.
--    The Roman-8 symbol set has a hex encoding of 0x0115.  Other
--    symbol sets are listed in the PCL 5 Comparison Guide in table
--    C-1 Symbol Set Values.  Standard Printer MIB (prt...objects) and Host Resources
--    MIB (hr...objects) strings do not contain symbol set information. 
--
-- 2) Some of the objects included are only supported if an accessory
--    is installed.  These accessories include:
--      MIO/EIO based accessories
--      SIMM/DIMM based accessories
--      Paper handling accessories
--
--
CLJ8550-MIB DEFINITIONS ::= BEGIN

hp OBJECT IDENTIFIER ::= { iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) 11}
dm OBJECT IDENTIFIER ::= { hp nm(2) hpsystem(3) net-peripheral(9) netdm(4) 2}

DisplayString ::= OCTET STRING

device                                 OBJECT IDENTIFIER ::=  { dm 1 } 
system                                 OBJECT IDENTIFIER ::=  { device 1 } 
settings-system                        OBJECT IDENTIFIER ::=  { system 1 } 
status-system                          OBJECT IDENTIFIER ::=  { system 2 } 
background-message                     OBJECT IDENTIFIER ::=  { status-system 37 } 
background-message1                    OBJECT IDENTIFIER ::=  { background-message 1 } 
background-message2                    OBJECT IDENTIFIER ::=  { background-message 2 } 
id                                     OBJECT IDENTIFIER ::=  { system 3 } 
interface                              OBJECT IDENTIFIER ::=  { system 4 } 
simm                                   OBJECT IDENTIFIER ::=  { interface 1 } 
simm1                                  OBJECT IDENTIFIER ::=  { simm 1 } 
simm2                                  OBJECT IDENTIFIER ::=  { simm 2 } 
simm3                                  OBJECT IDENTIFIER ::=  { simm 3 } 
simm4                                  OBJECT IDENTIFIER ::=  { simm 4 } 
simm5                                  OBJECT IDENTIFIER ::=  { simm 5 } 
simm6                                  OBJECT IDENTIFIER ::=  { simm 6 } 
simm7                                  OBJECT IDENTIFIER ::=  { simm 7 } 
simm8                                  OBJECT IDENTIFIER ::=  { simm 8 } 
mio                                    OBJECT IDENTIFIER ::=  { interface 3 } 
mio1                                   OBJECT IDENTIFIER ::=  { mio 1 } 
mio2                                   OBJECT IDENTIFIER ::=  { mio 2 } 
phd                                    OBJECT IDENTIFIER ::=  { interface 5 } 
phd1                                   OBJECT IDENTIFIER ::=  { phd 1 } 
phd2                                   OBJECT IDENTIFIER ::=  { phd 2 } 
phd3                                   OBJECT IDENTIFIER ::=  { phd 3 } 
phd4                                   OBJECT IDENTIFIER ::=  { phd 4 } 
phd5                                   OBJECT IDENTIFIER ::=  { phd 5 } 
phd6                                   OBJECT IDENTIFIER ::=  { phd 6 } 
test                                   OBJECT IDENTIFIER ::=  { system 5 } 
job                                    OBJECT IDENTIFIER ::=  { system 6 } 
settings-job                           OBJECT IDENTIFIER ::=  { job 1 } 
active-print-jobs                      OBJECT IDENTIFIER ::=  { job 2 } 
job-being-parsed                       OBJECT IDENTIFIER ::=  { active-print-jobs 1 } 
job-info                               OBJECT IDENTIFIER ::=  { job 5 } 
job-info-attribute                     OBJECT IDENTIFIER ::=  { job-info 23 } 
held-job                               OBJECT IDENTIFIER ::=  { job 7 } 
held-job-info                          OBJECT IDENTIFIER ::=  { held-job 1 } 
held-job-control                       OBJECT IDENTIFIER ::=  { held-job 2 } 
file-system                            OBJECT IDENTIFIER ::=  { system 10 } 
settings-file-system                   OBJECT IDENTIFIER ::=  { file-system 1 } 
status-file-system                     OBJECT IDENTIFIER ::=  { file-system 2 } 
file-systems                           OBJECT IDENTIFIER ::=  { file-system 3 } 
file-system2                           OBJECT IDENTIFIER ::=  { file-systems 2 } 
errorlog                               OBJECT IDENTIFIER ::=  { system 11 } 
error1                                 OBJECT IDENTIFIER ::=  { errorlog 1 } 
error2                                 OBJECT IDENTIFIER ::=  { errorlog 2 } 
error3                                 OBJECT IDENTIFIER ::=  { errorlog 3 } 
error4                                 OBJECT IDENTIFIER ::=  { errorlog 4 } 
error5                                 OBJECT IDENTIFIER ::=  { errorlog 5 } 
error6                                 OBJECT IDENTIFIER ::=  { errorlog 6 } 
error7                                 OBJECT IDENTIFIER ::=  { errorlog 7 } 
error8                                 OBJECT IDENTIFIER ::=  { errorlog 8 } 
error9                                 OBJECT IDENTIFIER ::=  { errorlog 9 } 
error10                                OBJECT IDENTIFIER ::=  { errorlog 10 } 
error11                                OBJECT IDENTIFIER ::=  { errorlog 11 } 
error12                                OBJECT IDENTIFIER ::=  { errorlog 12 } 
error13                                OBJECT IDENTIFIER ::=  { errorlog 13 } 
error14                                OBJECT IDENTIFIER ::=  { errorlog 14 } 
error15                                OBJECT IDENTIFIER ::=  { errorlog 15 } 
error16                                OBJECT IDENTIFIER ::=  { errorlog 16 } 
error17                                OBJECT IDENTIFIER ::=  { errorlog 17 } 
error18                                OBJECT IDENTIFIER ::=  { errorlog 18 } 
error19                                OBJECT IDENTIFIER ::=  { errorlog 19 } 
error20                                OBJECT IDENTIFIER ::=  { errorlog 20 } 
error21                                OBJECT IDENTIFIER ::=  { errorlog 21 } 
error22                                OBJECT IDENTIFIER ::=  { errorlog 22 } 
error23                                OBJECT IDENTIFIER ::=  { errorlog 23 } 
error24                                OBJECT IDENTIFIER ::=  { errorlog 24 } 
error25                                OBJECT IDENTIFIER ::=  { errorlog 25 } 
error26                                OBJECT IDENTIFIER ::=  { errorlog 26 } 
error27                                OBJECT IDENTIFIER ::=  { errorlog 27 } 
error28                                OBJECT IDENTIFIER ::=  { errorlog 28 } 
error29                                OBJECT IDENTIFIER ::=  { errorlog 29 } 
error30                                OBJECT IDENTIFIER ::=  { errorlog 30 } 
error31                                OBJECT IDENTIFIER ::=  { errorlog 31 } 
error32                                OBJECT IDENTIFIER ::=  { errorlog 32 } 
error33                                OBJECT IDENTIFIER ::=  { errorlog 33 } 
error34                                OBJECT IDENTIFIER ::=  { errorlog 34 } 
error35                                OBJECT IDENTIFIER ::=  { errorlog 35 } 
error36                                OBJECT IDENTIFIER ::=  { errorlog 36 } 
error37                                OBJECT IDENTIFIER ::=  { errorlog 37 } 
error38                                OBJECT IDENTIFIER ::=  { errorlog 38 } 
error39                                OBJECT IDENTIFIER ::=  { errorlog 39 } 
error40                                OBJECT IDENTIFIER ::=  { errorlog 40 } 
error41                                OBJECT IDENTIFIER ::=  { errorlog 41 } 
error42                                OBJECT IDENTIFIER ::=  { errorlog 42 } 
error43                                OBJECT IDENTIFIER ::=  { errorlog 43 } 
error44                                OBJECT IDENTIFIER ::=  { errorlog 44 } 
error45                                OBJECT IDENTIFIER ::=  { errorlog 45 } 
error46                                OBJECT IDENTIFIER ::=  { errorlog 46 } 
error47                                OBJECT IDENTIFIER ::=  { errorlog 47 } 
error48                                OBJECT IDENTIFIER ::=  { errorlog 48 } 
error49                                OBJECT IDENTIFIER ::=  { errorlog 49 } 
error50                                OBJECT IDENTIFIER ::=  { errorlog 50 } 
remote-procedure-call                  OBJECT IDENTIFIER ::=  { system 13 } 
settings-rpc                           OBJECT IDENTIFIER ::=  { remote-procedure-call 1 } 
status-rpc                             OBJECT IDENTIFIER ::=  { remote-procedure-call 2 } 
rpc-services                           OBJECT IDENTIFIER ::=  { remote-procedure-call 3 } 
nfs-server                             OBJECT IDENTIFIER ::=  { rpc-services 2 } 
settings-nfs-server                    OBJECT IDENTIFIER ::=  { nfs-server 1 } 
status-nfs-server                      OBJECT IDENTIFIER ::=  { nfs-server 2 } 
rpc-bind                               OBJECT IDENTIFIER ::=  { rpc-services 3 } 
settings-rpc-bind                      OBJECT IDENTIFIER ::=  { rpc-bind 1 } 
status-rpc-bind                        OBJECT IDENTIFIER ::=  { rpc-bind 2 } 
xport-interface                        OBJECT IDENTIFIER ::=  { system 14 } 
status-xip                             OBJECT IDENTIFIER ::=  { xport-interface 2 } 
source-subsystem                       OBJECT IDENTIFIER ::=  { device 2 } 
io                                     OBJECT IDENTIFIER ::=  { source-subsystem 1 } 
settings-io                            OBJECT IDENTIFIER ::=  { io 1 } 
ports                                  OBJECT IDENTIFIER ::=  { io 3 } 
port1                                  OBJECT IDENTIFIER ::=  { ports 1 } 
processing-subsystem                   OBJECT IDENTIFIER ::=  { device 3 } 
pdl                                    OBJECT IDENTIFIER ::=  { processing-subsystem 3 } 
settings-pdl                           OBJECT IDENTIFIER ::=  { pdl 1 } 
status-pdl                             OBJECT IDENTIFIER ::=  { pdl 2 } 
pdl-pcl                                OBJECT IDENTIFIER ::=  { pdl 3 } 
pdl-postscript                         OBJECT IDENTIFIER ::=  { pdl 4 } 
pjl                                    OBJECT IDENTIFIER ::=  { processing-subsystem 5 } 
jetsend-proc-sub                       OBJECT IDENTIFIER ::=  { processing-subsystem 8 } 
settings-jetsend                       OBJECT IDENTIFIER ::=  { jetsend-proc-sub 1 } 
jetsend-contact                        OBJECT IDENTIFIER ::=  { jetsend-proc-sub 3 } 
settings-jetsend-contact               OBJECT IDENTIFIER ::=  { jetsend-contact 1 } 
destination-subsystem                  OBJECT IDENTIFIER ::=  { device 4 } 
print-engine                           OBJECT IDENTIFIER ::=  { destination-subsystem 1 } 
status-prt-eng                         OBJECT IDENTIFIER ::=  { print-engine 2 } 
intray                                 OBJECT IDENTIFIER ::=  { print-engine 3 } 
settings-intray                        OBJECT IDENTIFIER ::=  { intray 1 } 
intrays                                OBJECT IDENTIFIER ::=  { intray 3 } 
intray1                                OBJECT IDENTIFIER ::=  { intrays 1 } 
intray2                                OBJECT IDENTIFIER ::=  { intrays 2 } 
intray3                                OBJECT IDENTIFIER ::=  { intrays 3 } 
intray4                                OBJECT IDENTIFIER ::=  { intrays 4 } 
intray5                                OBJECT IDENTIFIER ::=  { intrays 5 } 
outbin                                 OBJECT IDENTIFIER ::=  { print-engine 4 } 
settings-outbin                        OBJECT IDENTIFIER ::=  { outbin 1 } 
outbins                                OBJECT IDENTIFIER ::=  { outbin 3 } 
outbin1                                OBJECT IDENTIFIER ::=  { outbins 1 } 
outbin2                                OBJECT IDENTIFIER ::=  { outbins 2 } 
outbin3                                OBJECT IDENTIFIER ::=  { outbins 3 } 
outbin4                                OBJECT IDENTIFIER ::=  { outbins 4 } 
outbin5                                OBJECT IDENTIFIER ::=  { outbins 5 } 
outbin6                                OBJECT IDENTIFIER ::=  { outbins 6 } 
outbin7                                OBJECT IDENTIFIER ::=  { outbins 7 } 
outbin8                                OBJECT IDENTIFIER ::=  { outbins 8 } 
outbin9                                OBJECT IDENTIFIER ::=  { outbins 9 } 
outbin10                               OBJECT IDENTIFIER ::=  { outbins 10 } 
outbin11                               OBJECT IDENTIFIER ::=  { outbins 11 } 
marking-agent                          OBJECT IDENTIFIER ::=  { print-engine 5 } 
settings-marking-agent                 OBJECT IDENTIFIER ::=  { marking-agent 1 } 
imaging                                OBJECT IDENTIFIER ::=  { print-engine 6 } 
ph                                     OBJECT IDENTIFIER ::=  { print-engine 7 } 
ph-devices                             OBJECT IDENTIFIER ::=  { ph 3 } 
ph2                                    OBJECT IDENTIFIER ::=  { ph-devices 2 } 
ph3                                    OBJECT IDENTIFIER ::=  { ph-devices 3 } 
print-media                            OBJECT IDENTIFIER ::=  { print-engine 8 } 
settings-print-media                   OBJECT IDENTIFIER ::=  { print-media 1 } 
media-info                             OBJECT IDENTIFIER ::=  { print-media 3 } 
media1                                 OBJECT IDENTIFIER ::=  { media-info 1 } 
media2                                 OBJECT IDENTIFIER ::=  { media-info 2 } 
media3                                 OBJECT IDENTIFIER ::=  { media-info 3 } 
media4                                 OBJECT IDENTIFIER ::=  { media-info 4 } 
media5                                 OBJECT IDENTIFIER ::=  { media-info 5 } 
media6                                 OBJECT IDENTIFIER ::=  { media-info 6 } 
media7                                 OBJECT IDENTIFIER ::=  { media-info 7 } 
media8                                 OBJECT IDENTIFIER ::=  { media-info 8 } 
media9                                 OBJECT IDENTIFIER ::=  { media-info 9 } 
media10                                OBJECT IDENTIFIER ::=  { media-info 10 } 
media11                                OBJECT IDENTIFIER ::=  { media-info 11 } 
media12                                OBJECT IDENTIFIER ::=  { media-info 12 } 
media13                                OBJECT IDENTIFIER ::=  { media-info 13 } 
media14                                OBJECT IDENTIFIER ::=  { media-info 14 } 
media15                                OBJECT IDENTIFIER ::=  { media-info 15 } 
tables                                 OBJECT IDENTIFIER ::=  { device 7 } 
channel-table                          OBJECT IDENTIFIER ::=  { tables 2 } 
channel-entry                          OBJECT IDENTIFIER ::=  { channel-table 1 } 
resource-manager                       OBJECT IDENTIFIER ::=  { system 12 } 
mass-storage-resources                 OBJECT IDENTIFIER ::=  { resource-manager 3 } 
hrm                                    OBJECT IDENTIFIER ::=  { dm 3 } 
hrDevice                               OBJECT IDENTIFIER ::=  { hrm 3 } 
hrDiskStorageTable                     OBJECT IDENTIFIER ::=  { hrDevice 6 } 
hrDiskStorageEntry                     OBJECT IDENTIFIER ::=  { hrDiskStorageTable 1 } 
hrPartitionTable                       OBJECT IDENTIFIER ::=  { hrDevice 7 } 
hrPartitionEntry                       OBJECT IDENTIFIER ::=  { hrPartitionTable 1 } 
hrFSTable                              OBJECT IDENTIFIER ::=  { hrDevice 8 } 
hrFSEntry                              OBJECT IDENTIFIER ::=  { hrFSTable 1 } 
hrStorage                              OBJECT IDENTIFIER ::=  { hrm 2 } 
hrStorageTable                         OBJECT IDENTIFIER ::=  { hrStorage 3 } 
hrStorageEntry                         OBJECT IDENTIFIER ::=  { hrStorageTable 1 } 
hrDeviceTable                          OBJECT IDENTIFIER ::=  { hrDevice 2 } 
hrDeviceEntry                          OBJECT IDENTIFIER ::=  { hrDeviceTable 1 } 
hrPrinterTable                         OBJECT IDENTIFIER ::=  { hrDevice 5 } 
hrPrinterEntry                         OBJECT IDENTIFIER ::=  { hrPrinterTable 1 } 
channel                                OBJECT IDENTIFIER ::=  { device 6 } 
channelTable                           OBJECT IDENTIFIER ::=  { channel 3 } 
channelEntry                           OBJECT IDENTIFIER ::=  { channelTable 1 } 
print-engine-test                      OBJECT IDENTIFIER ::=  { print-engine 9 } 
printmib                               OBJECT IDENTIFIER ::=  { dm 2 } 
prtGeneral                             OBJECT IDENTIFIER ::=  { printmib 5 } 
prtGeneralTable                        OBJECT IDENTIFIER ::=  { prtGeneral 1 } 
prtGeneralEntry                        OBJECT IDENTIFIER ::=  { prtGeneralTable 1 } 
prtCover                               OBJECT IDENTIFIER ::=  { printmib 6 } 
prtCoverTable                          OBJECT IDENTIFIER ::=  { prtCover 1 } 
prtCoverEntry                          OBJECT IDENTIFIER ::=  { prtCoverTable 1 } 
prtLocalization                        OBJECT IDENTIFIER ::=  { printmib 7 } 
prtLocalizationTable                   OBJECT IDENTIFIER ::=  { prtLocalization 1 } 
prtLocalizationEntry                   OBJECT IDENTIFIER ::=  { prtLocalizationTable 1 } 
prtStorageRefTable                     OBJECT IDENTIFIER ::=  { prtGeneral 2 } 
prtStorageRefEntry                     OBJECT IDENTIFIER ::=  { prtStorageRefTable 1 } 
prtDeviceRefTable                      OBJECT IDENTIFIER ::=  { prtGeneral 3 } 
prtDeviceRefEntry                      OBJECT IDENTIFIER ::=  { prtDeviceRefTable 1 } 
prtInput                               OBJECT IDENTIFIER ::=  { printmib 8 } 
prtInputTable                          OBJECT IDENTIFIER ::=  { prtInput 2 } 
prtInputEntry                          OBJECT IDENTIFIER ::=  { prtInputTable 1 } 
prtOutput                              OBJECT IDENTIFIER ::=  { printmib 9 } 
prtOutputTable                         OBJECT IDENTIFIER ::=  { prtOutput 2 } 
prtOutputEntry                         OBJECT IDENTIFIER ::=  { prtOutputTable 1 } 
prtMarker                              OBJECT IDENTIFIER ::=  { printmib 10 } 
prtMarkerTable                         OBJECT IDENTIFIER ::=  { prtMarker 2 } 
prtMarkerEntry                         OBJECT IDENTIFIER ::=  { prtMarkerTable 1 } 
prtMarkerSupplies                      OBJECT IDENTIFIER ::=  { printmib 11 } 
prtMarkerSuppliesTable                 OBJECT IDENTIFIER ::=  { prtMarkerSupplies 1 } 
prtMarkerSuppliesEntry                 OBJECT IDENTIFIER ::=  { prtMarkerSuppliesTable 1 } 
prtMediaPath                           OBJECT IDENTIFIER ::=  { printmib 13 } 
prtMediaPathTable                      OBJECT IDENTIFIER ::=  { prtMediaPath 4 } 
prtMediaPathEntry                      OBJECT IDENTIFIER ::=  { prtMediaPathTable 1 } 
prtChannel                             OBJECT IDENTIFIER ::=  { printmib 14 } 
prtChannelTable                        OBJECT IDENTIFIER ::=  { prtChannel 1 } 
prtChannelEntry                        OBJECT IDENTIFIER ::=  { prtChannelTable 1 } 
prtInterpreter                         OBJECT IDENTIFIER ::=  { printmib 15 } 
prtInterpreterTable                    OBJECT IDENTIFIER ::=  { prtInterpreter 1 } 
prtInterpreterEntry                    OBJECT IDENTIFIER ::=  { prtInterpreterTable 1 } 
prtConsoleDisplayBuffer                OBJECT IDENTIFIER ::=  { printmib 16 } 
prtConsoleDisplayBufferTable           OBJECT IDENTIFIER ::=  { prtConsoleDisplayBuffer 5 } 
prtConsoleDisplayBufferEntry           OBJECT IDENTIFIER ::=  { prtConsoleDisplayBufferTable 1 } 
prtConsoleLights                       OBJECT IDENTIFIER ::=  { printmib 17 } 
prtConsoleLightTable                   OBJECT IDENTIFIER ::=  { prtConsoleLights 6 } 
prtConsoleLightEntry                   OBJECT IDENTIFIER ::=  { prtConsoleLightTable 1 } 
prtAlert                               OBJECT IDENTIFIER ::=  { printmib 18 } 
prtAlertTable                          OBJECT IDENTIFIER ::=  { prtAlert 1 } 
prtAlertEntry                          OBJECT IDENTIFIER ::=  { prtAlertTable 1 } 


energy-star OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Returns or changes the Energy Star sleep value.  If the
                value is greater than zero, then the device will go into
                energy saving sleep mode after the print engine has been
                idle for the number of seconds specified by this object.
                A value of zero means Energy Star is disabled and the
                device will not go to sleep based on print engine idle
                time.  The value must be non-negative.
                Additional information:
                Returns or changes the Energy Star sleep value. 
                The device will go into energy saving sleep 
                mode after the print engine has been idle for 
                the number of seconds specified by this 
                object. Color LaserJet8550 supports values of 10, 1800, 
                3600, 10800, 28800. 
                Setting to an unsupported value causes  
                the printer to substitute a value (listed 
                below) and to return <noError> 
                status.  
                The values for normal operation are as follow:  
                >=0  and <= 15 snap to 10  
                >= 16 and <= 2699 snap to 1800 (30 minutes)  
                >= 2700 and <= 5399 snap to 3600 (60 minutes)  
                			>= 5400 and <= 16199 snap to 10800 (180 minutes)   
                			>= 16200 snap to 28800 (480 minutes)  "
::= { settings-system 1 }
               
               
sleep-mode OBJECT-TYPE
    SYNTAX  INTEGER {
		   eFalse(1),
		   eTrue(2)
		   }
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Returns eTrue if the device is in energy saving sleep
                mode, otherwise returns eFalse.  Setting SLEEP-MODE to
                eFalse causes the device to wake up, if it is in sleep
                mode.  Setting SLEEP-MODE to eTrue causes the device to
                go into sleep mode.
                Additional information:
                Setting SLEEP-MODE to eTrue causes the device 
                			to go into sleep mode.
                			Setting this object to eTrue while printer is 
                awake will not change the printer's current state 
                			and will return <genErr> 
                			status.  
                Setting this object to eTrue while printer is 
                already in the Sleep Mode will not change the 
                printer's current state and will return <noError> status.  
                			Setting this object to eFalse while the printer is
                			asleep causes the device to wake up.  
                Setting eFalse while printer is already awake  
                will not change the printer's 
                current state and will return <noError> status."
::= { settings-system 2 }
               
               
on-off-line OBJECT-TYPE
    SYNTAX  INTEGER {
		   eOnline(1),
		   eOffline(2),
		   eOfflineAtEndOfJob(3)
		   }
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "To bring the PDL processing sub-system on or off line.
                If the device is a printer, then the printer does not
                process print job data when the printer is off line.
                PML communication persists.
                Additional information:
                When the printer is in the Offline state, 
                printing will stop as soon as possible (no more sheets 
                of media are pulled from input trays). All I/O 
                communication continues (no change from the Online 
                state).  
                			  
                Setting to eOnline has the following affect:  
                Printer will immediately go to or remain in the Online 
                state; <noError> status is returned.  
                If the printer's current state 
                is Offline with a pending error condition that 
                prevents the printer from going to the Online 
                state, the printer will remain in the Offline state; 
                <genErr> status is returned.   
                Setting to eOffline has the following affect:  
                Printer will immediately go to or remain in the 
                Offline state; <noError> status is returned.  
                If pages are being printed, those pages will complete 
                with the printer in the Offline state.  
                			  
                Setting to eOfflineAtEndOfJob has the following 
                affect:  
                If not in a job or already in the Offline state, the 
                printer will immediately go to or remain in the 
                Offline state; <noError> status is returned.  
                If printing and the current state is Online, the 
                printer will remain in the Online state, with the 
                value of this object as eOfflineAtEndOfJob, until the 
                end of the job; <noError> status is returned. At the end of 
                the job, the printer goes to the Offline state and the 
                value of this object becomes eOffline. During the 
                			eOffine state, the printer will still rip and process 
                			jobs.  
                Setting this object to eOffline or eOnline before the 
                end of the job causes the action for that value to be 
                taken immediately."
::= { status-system 5 }
               
               
continue OBJECT-TYPE
    SYNTAX  INTEGER {
		   eInitiateAction(1)
		   }
    ACCESS  write-only
    STATUS  optional
    DESCRIPTION
                "A device can support a class of errors called
                continuable errors.  When a continuable error is
                encountered, the device requires a continue event to
                occur before the device will continue operation.  One
                continue event is setting the CONTINUE object to
                eInitiateAction.  Devices can support other continue
                events, like auto-continue.  A continue event causes the
                continuable error to be acknowledged, thus allowing the
                device to continue.  Each device needs to list the
                continuable errors.  If the device doesn't currently
                have an unacknowledged continuable error, the response
                will contain <genErr>.
                Additional information:
                Since Color LaserJet8550 does not have a CONTINUE key, 
                			the GO key is used to perform the continue operation 
                			at the control panel."
::= { status-system 6 }
               
               
auto-continue OBJECT-TYPE
    SYNTAX  INTEGER {
		   eOn(2)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Indicates if the device will automatically continue
                after encountering a continuable error.  If AUTO-
                CONTINUE is set to eOn, the device will automatically
                generate continue event to acknowledge continuable
                errors.  If AUTO-CONTINUE is set to eOff, then some
                other continue event will have to acknowledge the
                continuable error.
                Additional information:
                Indicates if the device will automatically continue
                		after encountering a continuable error. If AUTO-CONTINUE
                		is set to eOn (AUTO-CONTINUE is always on for Color LaserJet8550), the
                		device will automatically generate continue event to 
                		acknowledge continuable errors."
::= { status-system 7 }
               
               
job-input-auto-continue-timeout OBJECT-TYPE
    SYNTAX  INTEGER(-1..3600)
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "The number of seconds the device waits after a job
                related continuable error occurs before automatically
                continuing.  An example job related continuable error is
                the job requesting a media size that is not available.
                After the timeout expires, the device will continue
                processing the job as if a continue event occurred, such
                as the front panel continue key being pressed.  If the
                value is -1, the device does not automatically continue
                after a job related continuable error occurs.  If the
                value is 0, the device immediately continues.  If the
                value is greater than 0, the value represents the
                timeout value in seconds.
                Additional information:
                This object is used only for media requests 
                			(size and/or name).  
                			Color LaserJet8550 supports any value in the range of -1 to 3600. 
                			Setting to a value outside of that range causes  
                the printer to substitute a value (listed 
                below) and to return <noError> 
                status.  
                The values are as follow:  
                <-1 snaps to -1  
                >3600 snaps to 3600  (60 minutes)  
                			The action that occurs when this timeout expires is 
                			explained by JOB-INPUT-AUTO-CONTINUE-MODE. It is not 
                			the same as the CONTINUE object being set to 
                			eInitiateAction or the Go key being pressed on
                			the control panel. See 
                			the CONTINUE object description for information on the 
                			actions that occur for those conditions."
::= { status-system 35 }
               
               
job-input-auto-continue-mode OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns or sets the device behavior when the desired
                media is not currently available.
                  cCancelJob - The device cancels the job.  The device
                POS should explain what happens if this item is not the
                only item in the collection.
                  cAutoMediaSizeOverride - The device is allowed to
                substitute a different size media.
                  cAutoMediaNameOverride - The device is allowed to
                substitute a different media name.
                cUSMediaSizeOverride  The device is allowed to
                substitute US media sizes (letter, etc.) for ISO media
                sizes (A4, etc.).
                cISOMediaSizeOverride  The device is allowed to
                substitute ISO media sizes (A4, etc.) for US media
                sizes (letter, etc.).
                Additional information:
                This object applies to all media requests, 
                			including Manual Feed Requests.  
                			This object describes the action that is performed 
                			when the JOB-INPUT-AUTO-CONTINUE-TIMEOUT expires. 
                			The action performed by the CONTINUE object being 
                			set to eInitiateAction or the Go key being pressed on
                			the control panel may cause different actions. 
                			See the CONTINUE object 
                			description for information on the actions that occur 
                			for those conditions."
::= { status-system 36 }
               
               
background-status-msg-line1-part1 OBJECT-TYPE
    SYNTAX  DisplayString (SIZE(0..16))
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "The string displayed on the device's front panel in
                place of the printer's built-in background status
                string.  An example built-in background status string is
                '00 READY'.
                Additional information:
                 The display size for the Color LaserJet8550 printer is 2 by 16.
                			     The value of this object is displayed on the first
                			     line and the value of 
                			     BACKGROUND-STATUS-MSG-LINE2-PART1 is displayed on
                			     the second line of the display. Each object must
                			     be set independently. If line 2 has been set, and
                			     the next message to be displayed only requires 
                			     line 1, BACKGROUND-STATUS-MSG-LINE2-PART1 must be
                			     set to the null string to clear it.  
                			     This object allows a message to be displayed when 
                it is the highest priority message waiting to be
                			     displayed. Setting this object does not guarantee 
                			     the message will be displayed; and reading it 
                			     returns the value last written, not the currently 
                			     displayed message.   
                The priority assigned for displaying this message 
                is one lower than the PJL RDYMSG.  
                To clear the message, write a null string to both
                			     this object and 
                			     BACKGROUND-STATUS-MSG-LINE2-PART1.  
                			     While the object prtConsoleLocalization controls 
                			     the localization and symbol set usage of printer 
                			     generated messages, this object's message is 
                			     displayed using the symbol set (note: The default 
                			     symbol set is Roman-8 for HP - EFI may vary) 
                			     specified with the string. The default symbol set 
                			     is Roman-8; additional legal symbol sets are 
                			     ISOLatin5, ISOLatin2, HalfWidthKatakana, and
                			     ISOLatinCyrillic.   
                			     When either BACKGROUND-STATUS-MSG-LINE1-PART1 or 
                			     BACKGROUND-STATUS-MSG-LINE2-PART1 contains a 
                			     non-null value, both will be displayed."
::= { background-message1 1 }
               
               
background-status-msg-line2-part1 OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "The string displayed on the device's front panel in
                place of the printer's built-in background status
                string.  An example built-in background status string is
                '00 READY'.
                Additional information:
                See BACKGROUND-STATUS-MSG-LINE1-PART1"
::= { background-message2 1 }
               
               
error-log-clear OBJECT-TYPE
    SYNTAX  INTEGER {
		   eClearErrorLog(1)
		   }
    ACCESS  write-only
    STATUS  optional
    DESCRIPTION
                "Setting this object clears all the entries in the error
                log sub-tree."
::= { status-system 38 }
               
               
job-output-auto-continue-timeout OBJECT-TYPE
    SYNTAX  INTEGER(-1..3600)
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns or sets the time that the printer will wait
                after an output bin becomes full and the printer is
                trying to deliver a sheet of media to that output bin.
                When the timeout expires, the job is processed according
                to the OUTBINn-OVERRIDE-MODE.  A value of -1 indicates
                that the printer will wait for a continue event.  A non-
                negative value is the number of seconds to wait.
                Additional information:
                Returns the time that the printer will wait 
                			after an output bin becomes full and the printer is 
                			trying to deliver a sheet of media to that output bin.
                			A value of -1 indicates that the printer will wait for 
                			a continue event."
::= { status-system 40 }
               
               
collated-originals-support OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Indicates that the printer can create multiple, collated
                'originals' of a job and shows the level of support for
                this capability.  
                  cCollatedOriginals - The printer can create multiple
                collated originals, or 'mopies'.  This is the base
                functionality required by the other collection items.  
                  cProofAndHold - The printer saves a copy of the job
                while printing the first mopy.  Later, this held job can
                be released and the rest of the mopies will print.  
                  cSecurityPrint - The printer spools the job and holds
                the job until the user releases the job by entering a
                password at the printer's control panel.  
                  cAutoHighlight - The printer prints  the job a number
                of times with a mail distribution list prepended to each
                job.  A different mailing address is highlighted on each
                mopy.  
                  cCollatedAtSpeed - The printer can create multiple
                collated copies where all copies after the original are
                printed at engine speed.
                Additional information:
                Indicates that the printer can create multiple, collated   
                originals of a job and shows the level of support for this  
                capability.    
                cCollatedOriginals - The printer can create multiple collated  
                originals, or mopies.  
                
                This is the base functionality required by the other   
                collection items.  None of them are supported by Color LaserJet8550.  
                Without disk, this object will not exist. This will be set at   
                boot-up initialization. If the disk fails, in any way, then   
                the disk error functionality will handle the situation.
                	       Note: Proof and print is not supported via PML."
::= { status-system 42 }
               
               
localization-languages-supported OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The list of languages supported by the device. The
                languages are primarily, but not limited to, two
                character codes from ISO 639, each separated by a comma
                character.
                Additional information:
                This string will always be in the Roman-8 character set. 
                		See prtLocalizationLanguage for details about each language 
                		value."
::= { status-system 52 }
               
               
localization-countries-supported OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The list of countries supported by the device. The
                countries are primarily, but not limited to, two
                character codes from ISO 3166, each separated by a comma
                character.
                Additional information:
                "
::= { status-system 53 }
               
               
model-number OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Identifies the device model number as listed in the HP
                corporate price list (e.g.  C2121A for DeskJet 500C).
                The string is as specific as possible.  Products should
                note in POS if the model number on the CPL changes but
                the device reports the previous model number.  If the
                model number changes based on the installed options, the
                POS should indicate if only the base model number is
                returned, or if the device senses the installed options
                and returns the correct model number.  If possible,
                encode the model number in a symbol set (like Roman-8)
                that matches the ASCII character set and limit the
                characters used to ASCII characters.
                Additional information:
                The value of this object does not change based on
                			the installed options."
::= { id 1 }
               
               
model-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Identifies the device model name (e.g.  ''DeskJet
                1200C'').  The string is as specific as possible.
                Capitalization and spacing should match family naming
                conventions.  Products should note in POS if the model
                name on the HP corporate price list changes but the
                device reports the previous device name.  If the model
                name changes based on the installed options, the POS
                should indicate if only the base model name is returned,
                or if the device senses the installed options and
                returns the correct model name.  If possible, encode the
                model name in a symbol set (like Roman-8) that matches
                the ASCII character set and limit the characters used to
                ASCII characters.
                Additional information:
                The value of this object does not change based on
                		the installed options.  
                		Since the value of this object is frequently used in 
                		displaying a list of printers, it is kept relatively short in 
                		case systems have limited width for their display area."
::= { id 2 }
               
               
serial-number OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Identifies the serial number for the device.  If the
                SERIAL-NUMBER object is set by the user, then setting
                the object does not need to be protected.  If the
                SERIAL-NUMBER object is set at the factory, then the
                SERVICE-PASSWORD object must be set correctly before the
                SERIAL-NUMBER object is writable.  If this is a writable
                object, the POS should indicate the maximum supported
                string length.  If possible, encode the serial number in
                a symbol set (like Roman-8) that matches the ASCII
                character set and limit the characters used to ASCII
                characters.
                Additional information:
                This value is affected by NVRAM resets, it is set 
                			to the default value of S4601LXXXXX, when a NVRAM
                			init is done.
                			This object is read-only so the SERVICE-PASSWORD 
                			object is not used."
::= { id 3 }
               
               
device-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "User defined device name.  The POS should indicate the
                maximum supported string length.  If the user entered
                string is too long, the device will store as much as
                possible and will return the <noError>.

                Additional information:
                 The maximum supported string length is 32  
                characters.  If the user entered string is too long, 
                the device will store the first 32 characters and will 
                return the <noError> status."
::= { id 10 }
               
               
device-location OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "User defined device location.  The POS should indicate
                the maximum supported string length.  If the user
                entered string is too long, the device will store as
                much as possible and will return the <noError>.

                Additional information:
                The maximum supported string length is 16 
                characters.  If the user entered string is too long, 
                the device will store the first 16 characters and will 
                return the <noError> status.  
                This object is saved in NVRAM."
::= { id 11 }
               
               
asset-number OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "User defined asset number.  The POS should indicate the
                maximum supported string length.  If the user entered
                string is too long, the device will store as much as
                possible and will return the <noError>.

                Additional information:
                The maximum supported string length is 8 
                characters.  If the user entered string is too long, 
                the device will store the first 8 characters and will  
                return the <noError> status.  
                This object is saved in NVRAM."
::= { id 12 }
               
               
simm1-type OBJECT-TYPE
    SYNTAX  INTEGER {
		   eEmpty(1),
		   eUnknown(2),
		   eUnSupported(3),
		   eReadOnlyMemory(4),
		   eVolatileRandomAccessMemory(5)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns an indication of the type of option installed in
                SIMM slot 1.
                  eEmpty means the device did not detect any option
                installed in the interface slot.
                  eUnknown means the device doesn't recognize the
                installed option.
                  eUnSupported means the device recognizes the installed
                option, but does not support the option.
                  eReadOnlyMemory means the installed option contains
                ROM Ics.
                  eVolatileRandomAccessMemory means the installed option
                contains RAM ICs that loose data when the power is
                turned off.
                  eNonVolatileRandomAccessMemory means that the
                installed option contains RAM ICs that do not loose data
                when the power is turned off.
                  eFlashMemory means that the installed option contains
                a type of non-volatile RAM that needs to be erased
                before it can be written.
                  eDiskDrive means the installed option contains a disk
                drive.  eRamRom means the installed option contains both
                volatile random access memory and read only memory.
                  eInputPHD means the installed option is an input paper
                handling device.
                  eOutputPHD means the installed option is an output
                paper handling device.
                  eIOCard means the installed option is an I/O card.
                Additional information:
                Returns an indication of the type of option 
                			installed in SIMM slot 1.
                			eEmpty means the device did not detect any option
                			installed in the interface slot.
                			eUnknown means the device doesn't recognize the 
                			installed option.
                			eUnSupported means the device recognizes the installed
                			option, but does not support the option.
                			eReadOnlyMemory means the installed option contains
                			ROMICs.
                			eVolatileRandomAccessMemory means the installed
                			option contains RAM ICs that loose data when the power
                			is turned off."
::= { simm1 4 }
               
               
simm1-capacity OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns an indication of the capacity of the SIMM
                installed in SIMM slot 1.  The capacity is dependent on
                the type of option, as indicated by the SIMM1-TYPE
                object.  This object has no meaning if the installed
                option type is eUnknown or eReadOnlyMemory.  This object
                contains the size, in bytes, if the installed option
                type is eVolatileRandomAccessMemory,
                eNonVolatileRandomAccessMemory, eFlashMemory, or
                eDiskDrive.  If the type of the installed option is
                eRamRom, this object contains the size, in bytes, of the
                random access memory.  If the type of the installed
                option is eInputPHD, the capacity indicates the number
                of input trays supported by the installed option.  If
                the type of the installed option is eOutputPHD, the
                capacity indicates the number of output bins supported
                by the installed option.  If the type of the installed
                option is eIOCard, the capacity indicates the number of
                logical I/O ports supported by the I/O card.
                Additional information:
                Returns an indication of the capacity of the 
                installed option in bytes.  This object is not 
                supported unless the SIMM1-TYPE type is 
                eVolatileRandomAccessMemory."
::= { simm1 5 }
               
               
simm2-type OBJECT-TYPE
    SYNTAX  INTEGER {
		   eEmpty(1),
		   eUnknown(2),
		   eUnSupported(3),
		   eReadOnlyMemory(4),
		   eVolatileRandomAccessMemory(5)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns an indication of the type of option installed in
                SIMM slot 2.  See SIMM1-TYPE for a description."
::= { simm2 4 }
               
               
simm2-capacity OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns an indication of the capacity of the SIMM
                installed in SIMM slot 2.  See SIMM1-CAPACITY for a
                description.
                Additional information:
                Returns an indication of the capacity of the 
                installed option in bytes.  This object is not 
                supported unless the SIMM2-TYPE type is 
                eVolatileRandomAccessMemory."
::= { simm2 5 }
               
               
simm3-type OBJECT-TYPE
    SYNTAX  INTEGER {
		   eEmpty(1),
		   eUnknown(2),
		   eUnSupported(3),
		   eReadOnlyMemory(4),
		   eVolatileRandomAccessMemory(5)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns an indication of the type of option installed in
                SIMM slot 3.  See SIMM1-TYPE for a description."
::= { simm3 4 }
               
               
simm3-capacity OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns an indication of the capacity of the SIMM
                installed in SIMM slot 3.  See SIMM1-CAPACITY for a
                description.
                Additional information:
                Returns an indication of the capacity of the 
                installed option in bytes.  This object is not 
                supported unless the SIMM3-TYPE type is 
                eVolatileRandomAccessMemory."
::= { simm3 5 }
               
               
simm4-type OBJECT-TYPE
    SYNTAX  INTEGER {
		   eEmpty(1),
		   eUnknown(2),
		   eUnSupported(3),
		   eReadOnlyMemory(4),
		   eVolatileRandomAccessMemory(5)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns an indication of the type of option installed in
                SIMM slot 4.  See SIMM1-TYPE for a description."
::= { simm4 4 }
               
               
simm4-capacity OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns an indication of the capacity of the SIMM
                installed in SIMM slot 4.  See SIMM1-CAPACITY for a
                description.
                Additional information:
                Returns an indication of the capacity of the 
                installed option in bytes.  This object is not 
                supported unless the SIMM4-TYPE type is 
                eVolatileRandomAccessMemory."
::= { simm4 5 }
               
               
simm5-type OBJECT-TYPE
    SYNTAX  INTEGER {
		   eEmpty(1),
		   eUnknown(2),
		   eUnSupported(3),
		   eReadOnlyMemory(4),
		   eVolatileRandomAccessMemory(5)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns an indication of the type of option installed in
                SIMM slot 5.  See SIMM1-TYPE for a description."
::= { simm5 4 }
               
               
simm5-capacity OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns an indication of the capacity of the SIMM
                installed in SIMM slot 5.  See SIMM1-CAPACITY for a
                description.
                Additional information:
                Returns an indication of the capacity of the 
                installed option in bytes.  This object is not 
                supported unless the SIMM5-TYPE type is 
                eVolatileRandomAccessMemory."
::= { simm5 5 }
               
               
simm6-type OBJECT-TYPE
    SYNTAX  INTEGER {
		   eEmpty(1),
		   eUnknown(2),
		   eUnSupported(3),
		   eReadOnlyMemory(4),
		   eVolatileRandomAccessMemory(5)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns an indication of the type of option installed in
                SIMM slot 6.  See SIMM1-TYPE for a description."
::= { simm6 4 }
               
               
simm6-capacity OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns an indication of the capacity of the SIMM
                installed in SIMM slot 6.  See SIMM1-CAPACITY for a
                description.
                Additional information:
                Returns an indication of the capacity of the 
                installed option in bytes.  This object is not 
                supported unless the SIMM6-TYPE type is 
                eVolatileRandomAccessMemory."
::= { simm6 5 }
               
               
simm7-type OBJECT-TYPE
    SYNTAX  INTEGER {
		   eEmpty(1),
		   eUnknown(2),
		   eUnSupported(3),
		   eReadOnlyMemory(4),
		   eVolatileRandomAccessMemory(5)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns an indication of the type of option installed in
                SIMM slot 7.  See SIMM1-TYPE for a description."
::= { simm7 4 }
               
               
simm7-capacity OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns an indication of the capacity of the SIMM
                installed in SIMM slot 7.  See SIMM1-CAPACITY for a
                description.
                Additional information:
                Returns an indication of the capacity of the 
                installed option in bytes.  This object is not 
                supported unless the SIMM7-TYPE type is 
                eVolatileRandomAccessMemory."
::= { simm7 5 }
               
               
simm8-type OBJECT-TYPE
    SYNTAX  INTEGER {
		   eEmpty(1),
		   eUnknown(2),
		   eUnSupported(3),
		   eReadOnlyMemory(4),
		   eVolatileRandomAccessMemory(5)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns an indication of the type of option installed in
                SIMM slot 8.  See SIMM1-TYPE for a description."
::= { simm8 4 }
               
               
simm8-capacity OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns an indication of the capacity of the SIMM
                installed in SIMM slot 8.  See SIMM1-CAPACITY for a
                description.
                Additional information:
                Returns an indication of the capacity of the 
                installed option in bytes.  This object is not 
                supported unless the SIMM8-TYPE type is 
                eVolatileRandomAccessMemory."
::= { simm8 5 }
               
               
mio1-model-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns product information identifying the I/O card.
                Example: XXXX"
::= { mio1 2 }
               
               
mio1-manufacturing-info OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns information describing the manufacture of the
                I/O card installed in MIO/EIO slot 1.  May include
                serial number and firmware revision.
                Additional information:
                The format of the string returned is determined by 
                		the manufacturer of the MIO card. There is no standard for 
                		content of the string. If no card is installed, a null string 
                		is returned."
::= { mio1 3 }
               
               
mio1-type OBJECT-TYPE
    SYNTAX  INTEGER {
		   eEmpty(1),
		   eUnknown(2),
		   eUnSupported(3),
		   eDiskDrive(8),
		   eIOCard(12)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns an indication of the type of option installed in
                MIO/EIO slot 1.  See SIMM1-TYPE for an explanation of
                the enumerations.
                Additional information:
                Returns an indication of the type of option installed 
                		in MIO/EIO slot 1. See SIMM1-TYPE for explanation of eEmpty,
                		eUnknown, and eUnSupported.
                		eDiskDrive means the installed option contains a disk drive.
                		eIOCard means the installed option is an I/O card."
::= { mio1 4 }
               
               
mio2-model-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns product information identifying the I/O card.
                Example: XXXX"
::= { mio2 2 }
               
               
mio2-manufacturing-info OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns information describing the manufacture of the
                I/O card installed in MIO/EIO slot 2.  May include
                serial number and firmware revision.
                Additional information:
                The format of the string returned is determined by 
                		the manufacturer of the MIO card. There is no standard for 
                		content of the string. If no card is installed, a null string 
                		is returned."
::= { mio2 3 }
               
               
mio2-type OBJECT-TYPE
    SYNTAX  INTEGER {
		   eEmpty(1),
		   eUnknown(2),
		   eUnSupported(3),
		   eDiskDrive(8),
		   eIOCard(12)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns an indication of the type of option installed in
                MIO/EIO slot 2.  See SIMM1-TYPE for an explanation of
                the enumerations.
                Additional information:
                Returns an indication of the type of option installed
                			in MIO/EIO slot 2. See MIO1-TYPE for an explanation of
                			the enumerations."
::= { mio2 4 }
               
               
phd1-type OBJECT-TYPE
    SYNTAX  INTEGER {
		   eEmpty(1)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns an indication of the type of option installed as
                PHD 1. See SIMM1-TYPE for an explanation of the
                enumerations.
                Additional information:
                 Color LaserJet8550 doesn't support envelope feeder but 
                			software reserves PHD1 for envelope feeder. 
                			All other PHD1 objects are removed."
::= { phd1 3 }
               
               
phd2-model OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns product information identifying PHD device 2.
                Additional information:
                If at least one (1) external paper handling
                			device is attached to the printer, then this object
                			will exist. Not applicable if the value of 
                			PHD2-TYPE is eEmpty.
                			Returns product information about the first paper
                			handling device in the device chain."
::= { phd2 1 }
               
               
phd2-manufacturing-info OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns information describing the manufacture of PHD 2.
                May include serial number and firmware revision.
                Additional information:
                If at least one (1) external paper handling 
                			device is attached to the printer, then this object 
                			will exist. Not applicable if the value of PHD2-TYPE
                			is eEmpty.
                			This object returns the name of the manufacturer of 
                			the first paper handling device."
::= { phd2 2 }
               
               
phd2-type OBJECT-TYPE
    SYNTAX  INTEGER {
		   eEmpty(1),
		   eInputPHD(10),
		   eOutputPHD(11)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns an indication of the type of option installed in
                PHD interface 2.  See SIMM1-TYPE for an explanation of
                the enumerations.
                Additional information:
                External paper handling devices are connected to 
                			the printer in a daisy-chained fashion. PHD2 refers 
                			to the first device that is connected. Returns eEmpty 
                			if no paper handling devices are installed.  
                			If the HCI is attached, the value will be eInputPHD. 
                			If the HCO is the first connected device, the value 
                			will be eOutputPHD."
::= { phd2 3 }
               
               
phd2-capacity OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns an indication of the capacity of the installed
                option.  See SIMM1-CAPACITY for an explanation of the
                meaning of the value of this object.
                Additional information:
                If at least one (1) external paper handling device (EPHD)
                		is attached to the printer, then this object will exist.
                		Not applicable if the value of PHD2-TYPE is eEmpty.
                		This object returns the number of input trays or output bins,
                		depending the device type (see PHD2-TYPE) for the first 
                		EPHD in the device chain."
::= { phd2 4 }
               
               
phd3-model OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns product information identifying PHD device 3.
                Additional information:
                If at least two (2) external paper handling devices
                			are attached to the printer, then this object will
                			exist. Not applicable if the value of PHD3-TYPE is 
                			eEmpty."
::= { phd3 1 }
               
               
phd3-manufacturing-info OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns information describing the manufacture of PHD 3.
                May include serial number and firmware revision.
                Additional information:
                If at least two (2) external paper handling 
                			devices are attached to the printer, then this object
                			will exist.  Not applicable if the value of PHD3-TYPE 
                			is eEmpty. This object returns the name of the 
                			manufacturer of the second paper handling device."
::= { phd3 2 }
               
               
phd3-type OBJECT-TYPE
    SYNTAX  INTEGER {
		   eEmpty(1),
		   eInputPHD(10),
		   eOutputPHD(11)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns an indication of the type of option installed in
                PHD interface 3.  See SIMM1-TYPE for an explanation of
                the enumerations.
                Additional information:
                External paper handling devices are connected to 
                			the printer in a daisy-chained fashion. PHD3 refers to 
                			the second device that is connected. Returns eEmpty if 
                			no paper handling devices are installed.
                			If the HCI is attached, the value will be eInputPHD.
                			If the HCO is the second connected device, the value
                			will be eOutputPHD."
::= { phd3 3 }
               
               
phd3-capacity OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns an indication of the capacity of the installed
                option.  See SIMM1-CAPACITY for an explanation of the
                meaning of the value of this object.
                Additional information:
                If at least two (2) external paper handling 
                			devices (EPHD) are attached to the printer, then 
                			this object will exist. Not applicable if the value
                			of PHD3-TYPE is eEmpty.
                			This object returns the number of input trays or
                			output bins, depending the device type (see 
                			PHD3-TYPE) for the second EPHD in the device chain."
::= { phd3 4 }
               
               
phd4-type OBJECT-TYPE
    SYNTAX  INTEGER {
		   eEmpty(1)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns an indication of the type of option installed in
                PHD interface 4.  See SIMM1-TYPE for an explanation of
                the enumerations.
                Additional information:
                External paper handling devices are connected to 
                			the printer in a daisy-chained fashion. PHD4 refers to 
                			the third device that is connected.   
                			Returns the type of the third party device in this 
                			chain, otherwise, eEmpty if only tow paper handling
                			devices are installed.
                			At introduction, there is no planned configuration 
                			that would cause the value of this object to be 
                			anything other than eEmpty."
::= { phd4 3 }
               
               
phd5-type OBJECT-TYPE
    SYNTAX  INTEGER {
		   eEmpty(1)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns an indication of the type of option installed in
                PHD interface 5.  See SIMM1-TYPE for an explanation of
                the enumerations.
                Additional information:
                External paper handling devices are connected to 
                			the printer in a daisy-chained fashion. PHD5 refers to 
                			the forth device that is connected. Returns eEmpty if 
                			only four paper handling devices are installed.  
                			At introduction, there is no planned configuration 
                			that would cause the value of this object to be 
                			anything other than eEmpty."
::= { phd5 3 }
               
               
phd6-type OBJECT-TYPE
    SYNTAX  INTEGER {
		   eEmpty(1)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns an indication of the type of option installed in
                PHD interface 6.  See SIMM1-TYPE for an explanation of
                the enumerations.
                Additional information:
                External paper handling devices are connected to 
                			the printer in a daisy-chained fashion. PHD6 refers to 
                			the fifth device that is connected. Returns eEmpty if 
                			only four paper handling devices are installed.  
                			At introduction, there is no planned configuration 
                			that would cause the value of this object to be 
                			anything other than eEmpty."
::= { phd6 3 }
               
               
self-test OBJECT-TYPE
    SYNTAX  INTEGER {
		   eNotInASelfTest(1),
		   eNonDestructiveSelfTest(4)
		   }
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Writing this object allows a device self test to be
                started.  Reading this object provides an indication
                what self-test is currently executing, if any.  Actual
                self-test operation is device specific.  A self test may
                not be allowed at any arbitrary time.  If the device
                supports the requested self test, but can not start the
                execution of the self test when requested, the device
                will respond with <genErr>.  If
                a non-destructive self test is being started, the device
                will generate a response before the self test is
                completed.
                RECOMMENDATION:  If the device is ready (i.e. the NOT-
                READY-PRINTER object does not contain any items, except
                maybe being off-line) and is idle (i.e. the NOT-IDLE
                object does not contain any items), this request should
                always succeed.  This provides a mechanism for driver
                writers to always determine if the action will succeed
                or not.
                Additional information:
                The eNonDestructiveSelfTest performs limited 
                testing on the printer and its attached paper handling 
                			devices. After the self-test is complete a 
                			configuration page is printed. The recommended way to 
                			cause a configuration page to be printed is to use the 
                			PRINT-INTERNAL-PAGE object. 
                A continuous self test cannot be started 
                or terminated using this OID.  
                When the printer is idle, setting this object to 
                eNonDestructiveSelfTest results in a status of <noError> 
                and a value of eNonDestructiveSelfTest being returned. 
                If the printer is not idle (whether printing an 
                external job, printing an internal page or running 
                self test), a status of 
                <genErr> status will be 
                returned with a value of eNotInASelfTest.
                When the printer is idle, setting this object to 
                eNonDestructiveSelfTest causes some internal testing, 
                the page to be formatted and put in the printer's 
                print queue. Before the page is in the print queue, a 
                get on this object will return eNonDestructiveSelfTest 
                Attempting to set this object before the page has 
                completed being formatted and printed will cause 
                <genErr> status to be 
                returned with a value of eNotInASelfTest.  
                After the page is in the queue, a get on this object 
                will return a value of eNotInASelfTest. 
                Setting this object to eNonDestructiveSelfTest 
                before the first page has completed results in 
                a status of <genErr> status 
                with a value of eNotInASelfTest.  
                Likewise, if the PRINT-INTERNAL-PAGE object is set to 
                a valid value and that page has not printed 
                when this object is set to eNonDestructiveSelfTest, a 
                status of <genErr> status 
                with a value of eNotInASelfTest will be 
                returned until the internal page has printed."
::= { test 1 }
               
               
print-internal-page OBJECT-TYPE
    SYNTAX  INTEGER {
		   eNotPrintingAnInternalPage(1),
		   ePrintingAnUnknownInternalPage(2),
		   eDeviceDemoPage1ConfigurationPage(3),
		   eDeviceDemoPage2(4),
		   eDeviceDemoPage5ErrorLog(7),
		   eDeviceDemoPage6FileSystemDirectoryListing(8),
		   eDeviceDemoPage7MenuMap(9),
		   ePCLFontList1(350),
		   ePostScriptFontList1(450),
		   eMarkingAgentTestPattern(1000)
		   }
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Writing this object to a value other than
                eNotPrintingAnInternalPage causes the device to attempt
                to print an internally generated page.  Reading this
                object provides an indication what internally generated
                page is currently being printed, if any.  The actual
                page is device specific.  Some devices may support
                continuously printing an internally generated page.
                Setting this object to eNotPrintingAnInternalPage
                terminates continuously printing internally generated
                pages.  An internally generated page may not be allowed
                to be printed at any arbitrary time; under what
                conditions it will succeed or fail is device specific.
                If the device supports the requested page, but can not
                start printing the page when requested, the device will
                respond with <genErr>.
                RECOMMENDATION:  If the device is ready (i.e. the NOT-
                READY-PRINTER object does not contain any items, except
                maybe being off-line) and is idle (i.e. the NOT-IDLE
                object does not contain any items), this request should
                always succeed.  This provides a mechanism for driver
                writers to always determine if the action will succeed
                or not.
                Additional information:
                PCL and PS config. pages for Color LaserJet8550 are the same.
                			Only 1 page for info on both PCL and PS. 
                			PCL and PS font lists are different. 
                			  
                			eDeviceDemoPage2 is the printer demo page. 
                ePCLFontList1 is the PCL typeface list. 
                eDeviceDemoPage5ErrorLog is the printer's error log. 
                Color LaserJet8550 does not support continuously printing a demo 
                page.   
                			  
                The value eDeviceDemoPage6FileSystemDirectoryListing 
                can only be set when the disk option is installed.
                			  
                When this object is set to a valid value and the 
                printer is idle, the status returned is <noError> and the 
                value returned is ePrintingAnUnknownInternalPage. If 
                the printer is not idle (whether printing an external 
                job, printing an internal page or executing a self 
                test), a status of <genErr> 
                status will be returned with a value of 
                eNotPrintingAnInternalPage.
                			  
                Setting this object to a valid value causes the 
                desired page to be formatted and put in the printer's 
                print queue. While the page is being formatted a get 
                on this object will return the value 
                ePrintingAnUnknownInternalPage, if 
                the time to format the page is long enough (it is 
                currently estimated that the time to format some pages 
                is as short as one millisecond). 
                Attempting to set this object before the page has 
                completed being formatted and printed will cause 
                <genErr> status to be 
                returned with a value of 
                eNotPrintingAnInternalPage.  
                			  
                After the page is in the queue, a get on this object 
                will return a value of eNotPrintingAnInternalPage. 
                Setting this object to cause another page to be 
                printed before the first page has completed results in 
                a status of <genErr> status 
                with a value of eNotPrintingAnInternalPage.  
                			  
                Likewise, if the SELF-TEST object is set to 
                eNonDestructiveSelfTest and that page has not printed 
                when this object is set to print a page, a status of 
                <genErr> status 
                with a value of eNotPrintingAnInternalPage will be 
                returned until the self test page has printed."
::= { test 2 }
               
               
cancel-job OBJECT-TYPE
    SYNTAX  INTEGER(0..32767)
    ACCESS  write-only
    STATUS  optional
    DESCRIPTION
                "Cancels the print job whose ID matches the value written
                to the CANCEL-JOB object.  The host first learns the job
                ID using the CURRENT-JOB-PARSING-ID command.  If the
                printer has completely processed the job, the printer
                responds with <badValue>.  If the
                value of the CURRENT-JOB-PARSING-ID is smaller than the
                value written to the CANCEL-JOB object, then the printer
                responds with <badValue>.  When
                read, returns the value of the last job ID what was
                canceled, or -1 to indicate no job has been canceled.
                Additional information:
                If the value written matches the ID of a job that is 
                		currently being canceled (for any reason), the printer 
                		responds with <noError>.  
                Color LaserJet8550 uses job ID's in the range of 0..32767. 
                Because the ID number can wrap to zero, CURRENT-JOB-PARSING-ID 
                		may be smaller than the value written to this object; when this
                		occurs, no error will result as long as the ID is for a 
                		currently processing job."
::= { settings-job 2 }
               
               
job-info-change-id OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(16))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the current value of an object in the job-info
                sub-tree whose value has changed.  Define the object
                identifier for the object whose value has changed as
                job-info.required-field.optional-field.job-id.  job-info
                represents the OID prefix of all objects in the job-info
                sub-tree.  Required-field represents the OID field value
                that follows the job-info prefix.  Since some objects in
                the job-info sub-tree have two OID fields between the
                job-info prefix and the job-id, the optional-field
                represents the OID field between the required-field and
                the job-id field, if present.  Using this definition,
                the format for the JOB-INFO-CHANGE-ID binary value can
                be described as follows:   
                  Bytes  0-3 :  required-field  
                  Bytes  4-7 :  optional-field, or all zeros if there   
                                is no optional field  
                  Bytes  8-11: Job ID.  
                  Bytes 12-n : The value of the object job-info.   
                               required-field.optional-field.job-id.
                All multi-byte values stored in Motorola (big-endian)
                format, where the most significant byte occurs first.
                Additional information:
                Color LaserJet8550 will use this object to report changes of the 
                job-info-pages-printed and job-info-state objects. 
                The required-field (bytes - through 3) will designate
                			whether the change to be reported involuves the pages
                			printed (13) or job state (15). The optionl-field
                			(bytes4 through 7) will always be zeroes. The value-
                			field (bytes 12 through 15) will contain the new value
                			for pages printed or job state cast to a 
                			32-byt integer."
::= { settings-job 3 }
               
               
hold-job-timeout OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "The time, in minutes, that the printer will wait before
                automatically deleting a held job.  This allows the
                printer to automatically clean up jobs that have been
                forgotten (held but never released).
                Additional information:
                This only applies to temporary held jobs, i.e., HOLD=ON or
                PROOF.  This is a global timer that only affects the jobs
                that are sent after it is set.
                		A value of 0 means never delete the jobs.
                		Setting it to an unsupported value causes
                		the printer to substitute a value (listed
                		below) and to return <noError>
                		status.  
                		Color LaserJet8550 supports values of 0, 60, 240, 1440, and 10080   
                		The values are as follows:  
                <=0 snap to 0   (disabled)  
                >=1 and <=150 snap to 60 (60 minutes)  
                >=151 and <=840 snap to 240 (4 hours)  
                >=841 and <=2880 snap to 1440 (1 day)  
                >=2881 snap to 10080  (1 week)"
::= { settings-job 10 }
               
               
current-job-parsing-id OBJECT-TYPE
    SYNTAX  INTEGER(-1..32767)
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains the printer assigned job identification for the
                job currently being processed by the processing PDL sub-
                system.  The job ID is a monotonically increasing
                number.  The job ID may be reset to zero at power-up and
                may roll over to zero after reaching some maximum
                value.
                Additional information:
                A value of -1 is returned when the printer is
                			not parsing a job.  
                			When data for a new job is detected, this object is 
                			updated (the job may or may not turn out to be a Null 
                			Job); however, the trap does not occur until the 
                			printer determines that it is not a Null Job 
                			(a trapped value will differ from the previous value
                			name or job attribute, causes no pages to be printed,
                			by one or more).   
                			Some JOB-INFO- objects are created when the first data 
                			bytes are received. If the printer determines that the 
                			job is a Null Job, the JOB-INFO- objects related to 
                			the Null Job are deleted. Color LaserJet8550 retains the 
                			JOB-INFO- objects for the 24 most recent jobs that are 
                			not Null Jobs."
::= { job-being-parsed 1 }
               
               
job-info-name1 OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains the first part of this print job's name.  The
                last OID field for this dynamic object contains the job
                ID.
                Additional information:
                The job name is the string specified by the
                NAME= parameter of the @PJL JOB command which  
                			allows a maximum of 80 characters. The first 40 
                			characters are in this object and the second 40 are in 
                			JOB-INFO-NAME2. The symbol set is Roman-8.  
                			When jobs are nested, the value assigned to this object
                			is the name provided by the most recent 
                			@PJL JOB NAME= command. If no name is provided, 
                			a null string is returned. "
::= { job-info 1 }
               
               
job-info-name2 OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains the second part of this print job's name.  The
                last OID field for this dynamic object contains the job
                ID.
                Additional information:
                See JOB-INFO-NAME1."
::= { job-info 2 }
               
               
job-info-stage OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Indicates what printer sub-systems are currently
                processing this print job.  The last OID field for this
                dynamic object contains the job ID.
                  cSourceSubsystem -  some of the job is in the printer
                I/O subsystem.
                  cProcessingSubsystem - some of the job is in the
                printer imaging processing subsystem.
                  cDestinationSubsystem -  some of the job is being
                printed.
                Additional information:
                For Color LaserJet8550 cSourceSubsystem and cProcessingSubsystem 
                		will always be set and cleared together.  
                		A non-printing job will never set cDestinationSubsystem.  
                		When a page is ready to be printed (the intermediate has been 
                		built), cDestinationSubsystem will be set even if
                		a page of a previous job is currently being printed. 
                		cDestinationSubsystem remains set until the last page of the 
                		job has reached an output bin.  
                		If a page requires extensive processing and allows all the 
                		previous pages of a job to complete printing 
                		cDestinationSubsystem will remain set until the last page of 
                		the job is closed."
::= { job-info 10 }
               
               
job-info-io-source OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Indicates which I/O source, the print job was received
                over.  The value maps to port numbering scheme supported
                in the DEVICE/SOURCE-SUBSYSTEM/IO/PORTS sub-tree."
::= { job-info 11 }
               
               
job-info-pages-processed OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Indicates the number of pages processed by the
                processing subsystem.  If neither the cSourceSubsystem
                or the cProcessingSubsystem items are in the associated
                JOB-INFO-STAGE object, then this object contains the
                total number of pages processed for this job.  The last
                OID field for this dynamic object contains the job ID.
                Additional information:
                This object is incremented by one when a page is 
                		processed, regardless of the number of pages that are printed 
                		as a result of the single page processed. In other words, 
                		it does not matter how many identical copies of a page are 
                		printed, or no pages may be printed if operating in silent 
                		run mode, this count is incremented only once.  
                		A page is considered processed when all of the input data has 
                		been processed for a page (the intermediate has been produced);
                		the image of the page is not necessarily completely formed."
::= { job-info 12 }
               
               
job-info-pages-printed OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Indicates the number of pages printed by the destination
                subsystem.  If non of the cSourceSubsystem,
                cProcessingSubsystem or cDestinationSubsystem items are
                in the associated JOB-INFO-STAGE object, then this
                object contains the total number of pages printed for
                this job.  This value may increase by two each time for
                duplex jobs.  The last OID field for this dynamic object
                contains the job ID.
                Additional information:
                Indicates the number of pages printed (i.e., the page 
                		has reached the output tray) by the destination subsystem.
                		If multiple copies of a page are printed, each copy
                		is counted individually. Duplexed pages count as 2 pages."
::= { job-info 13 }
               
               
job-info-size OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Indicates the number of bytes of data processed by the
                processing subsystem.  If neither of the
                cSourceSubsystem or cProcessingSubsystem items are in
                the associated JOB-INFO-STAGE object, then this object
                contains the size of this job, in bytes.  The last OID
                field for this dynamic object contains the job ID.
                Additional information:
                This count may be incremented by values other than one 
                		as blocks of data are processed; blocks of data (which may be 
                		as large as 2K bytes) will be processed in a varying amount of 
                		time.   
                		When a job completes, this count may not be the same as the 
                		total number of bytes sent to the printer since some data 
                		before or after the job may be considered to be outside the 
                		job. Also, for ill-formed PostScript jobs (ones that do not 
                		use the ENTER LANGUAGE command) will be reported as having 
                		approximately 256 extra bytes due to the way the language 
                		switching is accomplished."
::= { job-info 14 }
               
               
job-info-state OBJECT-TYPE
    SYNTAX  INTEGER {
		   eAborted(3),
		   eWaitingForResources(4),
		   ePrinted(5),
		   eRetained(6),
		   eTerminating(7),
		   ePaused(9),
		   eCancelled(10),
		   eProcessing(11)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Indicates the state of the job.  The last OID field for
                this dynamic object contains the job ID.  
                  eAborted - the print job was aborted.  
                  eWaitingForResources - the print job requires
                resources that are not currently available.  Example
                resources that can cause the job to wait include the
                print engine or PDL processor being unavailable.  The
                print engine could be unavailable due to paper out,
                paper jam, staple out, stapler jam, marking agent low,
                output bin full, etc.  The PDL processor could be
                unavailable due to an off-line condition.  Each printer
                specific object specification should state which
                conditions cause a job to be waiting for resources and
                also state which objects can be retrieved by an
                application to determine the exact cause of a resource
                being unavailable.  
                  ePrinted - the job has printed.  The related JOB-INFO-
                OUTCOME object indicates if any problems were
                encountered while the job was processed.  
                  eRetained - the job can be reprinted.  
                  eTerminating - the job was aborted or cancelled and is
                currently is terminating.  
                  eInterrupted - the job has been interrupted.  The job
                can be continued.  
                  ePaused - the job has been paused.  The job can be
                continuted.  
                  eCancelled - the job has been cancelled.  
                  eProcessing - the job is currently being printed
                normally.
                Additional information:
                Indicates the state of the job. The last OID field for 
                			this dynamic object contains the job ID  
                			eAborted - the print job was aborted.  
                			eWaitingForResources - the print job requires resources
                				that are not currently available. Example 
                				resources that can cause the job to wait 
                				include the print engine or PDL processor 
                				being unavailable due to paper out, paper jam, 
                				marking agent low, output bin full, etc. 
                				The PDL processor could be unavailable due to 
                				an off-line condition.  
                			ePrinted - the job has printed. The related 
                				JOB-INFO-OUTCOME object indicates if any 
                				problms were encountered while the job was 
                				precessed.   
                			eRetained - the job can be reprinted.  
                			eTerminating - the job was aborted or cancelled and is 
                				currently is terminating.
                			ePaused - the job has been paused. The job can be 
                				continued.  
                			eCancelled - the job has been cancelled.  
                			eProcessing - the job is currently being printed 
                				normally."
::= { job-info 15 }
               
               
job-info-outcome OBJECT-TYPE
    SYNTAX  INTEGER {
		   eOk(3),
		   eWarningsEncountered(4),
		   eErrorsEncountered(5)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Indicates if any warning or error conditions were
                encountered while processing the assoicated job.  The
                last OID field for this dynamic object contains the job
                ID."
::= { job-info 19 }
               
               
job-info-outbins-used OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Indicates which output bins this job has delivered
                printed pages to.  The last OID field for this dynamic
                object contains the job ID.
                Additional information:
                The bins designated by this collection include the
                		printer's own output bins as well as the 'logical output bins'
                		associated with any attached external paper handling devices. 
                		(The mapping of the physical output bins of an external paper
                		handling device to its 'logical output bins' depends on the
                		usage mode of the device. For instance, in 'mailbox mode', 
                		there is one-to-one correspondence of 'logical output bins' to 
                		physical bins, whereas in 'stacker mode', one 'logical output
                		bin' may map to several physical bins.)  
                		If a bin is used as an overflow bin, then its bit will be set 
                		as well.  
                		cOutbin1 is the top/face-down bin.  
                		cOutbin2 is the left/face-up bin.
                		"
::= { job-info 20 }
               
               
job-info-physical-outbins-used OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Indicates which physical output bins this job has
                delivered printed pages to.  The last OID field for this
                dynamic object contains the job ID.
                Additional information:
                Bits in this object are set only if printed pages were 
                		delivered to an external paper handling device. This object is 
                		supported regardless of whether or not an external device is 
                		installed. The bits set map to the device's bins in a device 
                		specific manner. If the device does not report to the formatter
                		which bins are used, then no bits will be set.
                		For the HCO, the bins map to the bits as follows:  
                		cOutbin1--Face-up bin  
                		cOutbin2--Bin1  
                		cOutbin3--Bin2  
                		cOutbin4--Bin3  
                		cOutbin5--Bin4  
                		cOutbin6--Bin5  
                		cOutbin7--Bin6  
                		cOutbin8--Bin7  
                		cOutbin9--Bin8   
                		cOutbin10--Bin9  "
::= { job-info 22 }
               
               
job-info-attr-1 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  Attribute objects are saved
                sequentially, starting with 1, after the start of a job.
                If more attributes are set than there are objects to
                store them, the excess JOBATTR values are ignored.  If
                the corresponding SET JOBATTR= command has not been
                received when a get is done for this object, a status of
                <noSuchName> will be returned."
::= { job-info-attribute 1 }
               
               
job-info-attr-2 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 2 }
               
               
job-info-attr-3 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 3 }
               
               
job-info-attr-4 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 4 }
               
               
job-info-attr-5 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 5 }
               
               
job-info-attr-6 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 6 }
               
               
job-info-attr-7 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 7 }
               
               
job-info-attr-8 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 8 }
               
               
job-info-attr-9 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 9 }
               
               
job-info-attr-10 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 10 }
               
               
job-info-attr-11 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 11 }
               
               
job-info-attr-12 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 12 }
               
               
job-info-attr-13 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 13 }
               
               
job-info-attr-14 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 14 }
               
               
job-info-attr-15 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 15 }
               
               
job-info-attr-16 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 16 }
               
               
job-info-attr-17 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 17 }
               
               
job-info-attr-18 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 18 }
               
               
job-info-attr-19 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 19 }
               
               
job-info-attr-20 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 20 }
               
               
job-info-attr-21 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 21 }
               
               
job-info-attr-22 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 22 }
               
               
job-info-attr-23 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 23 }
               
               
job-info-attr-24 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 24 }
               
               
job-info-attr-25 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 25 }
               
               
job-info-attr-26 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 26 }
               
               
job-info-attr-27 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 27 }
               
               
job-info-attr-28 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 28 }
               
               
job-info-attr-29 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 29 }
               
               
job-info-attr-30 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 30 }
               
               
job-info-attr-31 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 31 }
               
               
job-info-attr-32 OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(1..80))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the value that was set in PJL via the SET
                JOBATTR= command.  See JOB-INFO-ATTR-1 for details."
::= { job-info-attribute 32 }
               
               
job-info-requested-originals OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The number of requested collated copies.  The value was
                supplied with the job via PJL QTY variable, the
                PostScript Collate and NumCopies entries in the page
                device dictionary, or via some other mechansim."
::= { job-info 24 }
               
               
job-info-page-count-current-original OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The page number being printed within the current copy of
                a collated multi-copy job.  This value changes when the
                job-info-pages-printed changes.  The job-info-pages-
                printed indicates the total number of pages printed in
                the job, while this object indicates the number of pages
                printed for this copy of a collated multi-copy job."
::= { job-info 25 }
               
               
job-info-pages-in-original OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Number of pages in a single copy of a collated multi-
                copy job."
::= { job-info 26 }
               
               
job-info-printed-originals OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Number of collated copies completely printed and
                delivered to the output bin at time of query.
                Additional information:
                Number of collated copies completly printed at time of query."
::= { job-info 27 }
               
               
held-job-user-name OBJECT-TYPE
    SYNTAX  DisplayString (SIZE(0..40))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "User name that is obtained by the driver through some
                internal method or from user input.
                Additional information:
                The following is a general description for all the JOB-MANAGEMENT
                objects described below.  These object describe the attributes of the
                dynamic list containing all the stored jobs on the disk available for
                printing or deleting via the job-management feature.  The jobs on this
                list are not deleted from the disk unless explicitly specified by the
                user.  A print job may be specified for retention by PJL commands in the
                data stream.
                
                Following is a list of the PJL commands (i.e. these comments describe 
                the PJL implementation and in some cases do not reflect the PML 
                implementation.):
                
                @PJL SET HOLD=OFF|ON|PROOF|STORE|PRINT
                
                GENERAL DESCRIPTION: 
                
                This variable specifies the retention classification of the job.  The
                values indicate whether the job is printed immediately and/or stored.
                
                OFF:  The job is printed but not retained on disk after printing.  This
                is the default value.
                
                ON:  This setting may be thought of as free proof-and-hold.  The
                requested number of copies will be printed and the job will be
                temporarily stored on disk.  The job will then be available for printing
                additional copies through the control panel and through PML.  There will
                be a limit to the number of these temporary jobs that may be stored, and
                when the limit is exceeded the oldest job will be removed from the disk.
                
                PROOF:  One copy of the job is printed and remaining copies are stored
                on disk.  The job is then available to select for printing via the
                control panel menus or PML.  The job will be deleted from the disk when
                the disk space is needed for another proof and hold job but only after
                the additional copies have been printed.  It will also be deleted when
                the user sends down another proof and hold job with the same job name,
                or the user explicitly deletes the job.
                
                STORE:  The job is not printed immediately but is retained on disk.  The
                job is available to select for printing via the control panel
                
                DEFAULT VALUE: OFF
                
                The value will be stored in RAM only, not in NVRAM.
                The legal PJL commands are SET and INQUIRE.  DEFAULT is not allowed.
                The variable will appear in the PJL INFO VARIABLES list.
                
                @PJL SET USERNAME=<80 bytes>
                
                GENERAL DESCRIPTION: 
                
                Eighty-character user name that is obtained by the driver through some
                internal method or from user input.  If the job stream does not contain
                a USERNAME the default value will be NO USER NAME.  The driver is
                responsible for determining the size of the printers control panel and
                sending a string of appropriate length.
                
                DEFAULT VALUE: NO USER NAME
                
                The value will be stored in RAM only, not in NVRAM.
                The legal PJL commands are SET and, INQUIRE. DEFAULT is not allowed.
                The variable will appear in the PJL INFO VARIABLES list.
                
                @PJL SET JOBNAME=<80 bytes>
                
                GENERAL DESCRIPTION:
                
                Eighty-character job name that may be generated by the driver or
                obtained from user input.  This value may be used in conjunction with
                the USERNAME to select a job from the front panel.  If the job stream
                does not contain a JOBNAME, the printer will assume no job name; each
                subsequent job that is sent down by the same user would replace the
                users last job on disk.  The driver is responsible for determining the
                size of the printers control panel and sending a string of appropriate
                length.
                
                NOTE:  The limit of 80 bytes is a PJL limit.  The limit for PML will
                be 40 bytes.
                
                DEFAULT VALUE: NULL STRING
                
                The value will be stored in RAM only, not in NVRAM.
                The legal PJL commands are SET and INQUIRE. DEFAULT is not allowed.
                The variable will appear in the PJL INFO VARIABLES list.
                
                @PJL SET HOLDTYPE=PUBLIC|PRIVATE
                
                GENERAL DESCRIPTION:
                
                This variable specifies the privacy level of the job.
                
                PUBLIC:  The job does not require a PIN in order to be released for
                printing.  This is the default value.
                
                PRIVATE:  The job requires a PIN in order to be released for printing.
                The PIN is specified by the HOLDKEY variable.  If the
                
                HOLDTYPE is set to PRIVATE, a HOLDKEY value must be specified.  If no
                HOLDKEY is specified, the job will be considered PUBLIC.
                
                DEFAULT VALUE: PUBLIC
                
                The value will be stored in RAM only, not in NVRAM.
                The legal PJL commands are SET and INQUIRE. DEFAULT is not allowed.
                The variable will appear in the PJL INFO VARIABLES list.
                
                @PJL SET HOLDKEY=4 digits, 0000...9999
                
                GENERAL DESCRIPTION:
                
                A 4-digit string, each digit 0-9, that is specified in the job stream
                and then required to be entered in order to release the job for
                printing.  If a HOLDTYPE is PRIVATE, a HOLDKEY value must be specified.
                If no HOLDKEY value is specified, a job will be considered PUBLIC.
                
                DEFAULT VALUE: NULL STRING
                
                The value will be stored in RAM only, not in NVRAM.
                The legal PJL commands are SET and INQUIRE. DEFAULT is not allowed.
                The variable will appear in the PJL INFO VARIABLES list.
                
                
                The format for the OID is as follows:
                
                3.4.1.6.x.y
                <-----> | |
                |    |  \
                /     |  job-id in the system
                /       \   
                PML_JOB_MGNT_ROOT_OID  \
                job attribute 1..6
                
                x values are 1..6:
                
                1) user-name:  user name that is obtained by the driver through some
                internal method or from user input.
                
                2) job-name:  job name may be generated by the driver or obtained from
                user input.
                
                3) hold:  indicates the retention classification of the job.  The values
                indicate whether the job is printed immediately and/or stored.  There
                are 4 options:
                OFF:    The job is printed but not retained on the disk.
                ON:     The job is printed and stored temporarily on the disk.
                STORE:  The job is not printed but stored on the disk.
                PROOF:  One copy of the job is printed and the remaining copies are
                stored on the disk.
                
                4) holdtype:  The variable specifies the security level of the job.
                PUBLIC:  The job does not require a PIN in order to release the job for
                printing.
                PRIVATE:  The job requires a PIN in order to be released for printing.
                
                5) quantity:  number of copies to print.  Valid values are 0..999.
                
                6) pin:  A 4 digit string, each digit is 0-9, that is specified in the
                job stream and then required to be entered in order to release the job
                for printing.
                
                y :  an unsigned 15 bit number which uniquely identifies the job.  The job
                id for the job remains the same for the job until it is deleted from the
                held jobs list.
                
                
                For example, the OID below is asking for the user name of the
                job whose id is 3.  The application would issue:
                
                OID    
                get 3.4.1.6.1.3
                
                For example, the <getnext> OID values sequence is as follows:
                
                OID                returned OID
                getnext 3.4.1.6         3.4.1.6.1.1
                getnext 3.4.1.6.1.1     3.4.1.6.1.2
                getnext 3.4.1.6.2.1     3.4.1.6.2.2
                ...
                getnext 3.4.1.6.1.6     3.4.1.6.1.7
                getnext 3.4.1.6.2.1     3.4.1.6.2.2
                getnext 3.4.1.6.5.2828  3.4.1.6.6.1 
                
                NOTE: for example above, job id 2828 is the last job in the list of
                held jobs.
                ...
                
                Also supported is <getnext> on the job attributes:
                OID                returned OID
                getnext 3.4.1.6.1       3.4.1.6.1.1
                getnext 3.4.1.6.6       3.4.1.6.6.1"
::= { held-job-info 1 }
               
               
held-job-job-name OBJECT-TYPE
    SYNTAX  DisplayString (SIZE(0..40))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The job name may be generated by the driver or obtained
                from user input.
                Additional information:
                The job name may be generated by the driver or obtained
                from user input."
::= { held-job-info 2 }
               
               
held-job-retention OBJECT-TYPE
    SYNTAX  INTEGER {
		   eHoldOff(1),
		   eHoldOn(2),
		   eHoldStore(3),
		   eHoldProof(4)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Indicates the retention classification of the job.  The
                values indicate whether the job is printed immediately
                and/or stored.  There are 4 options:
OFF:    The job is printed but not retained on the disk.
ON:     The job is printed and stored temporarily on the disk.
PROOF:  One copy of the job is printed and the remaining copies are stored on the disk.
STORE:  The job is not printed but stored on the disk.
                Additional information:
                Indicates the retention classification of the job.  The
                values indicate whether the job is printed immediately
                and/or stored.  There are 4 options:
                OFF:   The job is printed but not retained on the disk.
                ON:    The job is printed and stored temporarily on the disk.
                PROOF: One copy of the job is printed and the remaining copies are stored on the disk.
                STORE: The job is not printed but stored on the disk."
::= { held-job-info 3 }
               
               
held-job-security OBJECT-TYPE
    SYNTAX  INTEGER {
		   eHoldTypePublic(1),
		   eHoldTypePrivate(2)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The variable specifies the security level of the job.
PUBLIC:  The job does not require a PIN in order to release the job for printing.
PRIVATE: The job requires a PIN in order to be released for printing.
                Additional information:
                The variable specifies the security level of the job.
                PUBLIC: The job does not require a PIN in order to release the job for printing.
                PRIVATE:The job requires a PIN in order to be released for printing."
::= { held-job-info 4 }
               
               
held-job-quantity OBJECT-TYPE
    SYNTAX  INTEGER(1..999)
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Number of copies to print.
                Additional information:
                Number of copies to print."
::= { held-job-info 5 }
               
               
held-job-pin OBJECT-TYPE
    SYNTAX  DisplayString (SIZE(0..4))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "A string that is specified in the job stream and then
                required to be entered in order to release the job for
                printing.  PIN stands for Personal Identification
                Number.
                Additional information:
                Must be a 4 digit string, each digit must be 0..9 or a null string
                if there is no pin."
::= { held-job-info 6 }
               
               
held-job-print OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(8))
    ACCESS  write-only
    STATUS  optional
    DESCRIPTION
                "Instructs the printer to schedule the specified held job
                for printing with the specified number of copies.  The
                job-id is used to identify which job to print.  A held
                job can also be printed from the control panel.
                Additional information:
                Bytes 0-3 is the job id of the job to print.
                Bytes 4-7 is the number of copies to print."
::= { held-job-control 1 }
               
               
held-job-delete OBJECT-TYPE
    SYNTAX  INTEGER(0..32768)
    ACCESS  write-only
    STATUS  optional
    DESCRIPTION
                "Instructs the printer to delete the specified held job
                from the list.  The job-id is used to identify which job
                to delete.  A held job can also be deleted from the
                control panel.
                Additional information:
                "
::= { held-job-control 2 }
               
               
held-job-set-queue-size OBJECT-TYPE
    SYNTAX  INTEGER(0..50)
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Sets the maximum number of jobs which can be stored in
                the held job list.
                Additional information:
                Sets the size of the temporary job lists queue."
::= { held-job-control 3 }
               
               
held-job-enable OBJECT-TYPE
    SYNTAX  INTEGER {
		   eDisabled(1),
		   eEnabled(2)
		   }
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Enables or disables Job Retention (Job Hold).  The valid
                values are eDisabled and eEnabled.  (Specifying an
                invalid mode causes an <badValue>
                error to be returned.) When eDisabled is specified all
                Job Retention (Hold, Proof, Store, PIN Printing) is
                disabled.  When eEnabled is specified, the Job Retention
                characteristics of a given job are defined by the PJL
                variable SET HOLD.
                Additional information:
                When disabled, currently held jobs are not removed,
                but must be explicitly removed through the Control Panel
                or the PML object HELD-JOB-DELETE."
::= { held-job-control 4 }
               
               
file-system-memory OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "The amount of memory, in bytes, used by the file system
                to buffer file data.
                Additional information:
                Reports the amount of memeory, in bytes, reserved for use 
                		by the file system. Returns status if attempting to access
                		this object and there is no storage device is installed.
                		The values remain constant across reboots. Possible values:
                		FILE-SYSTEM-MAX-OPEN-FILES 32 512 EIO DISK 69916 198556."
::= { settings-file-system 1 }
               
               
file-system-max-open-files OBJECT-TYPE
    SYNTAX  INTEGER(32..512)
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "The number of open files allowed at one time. Opening a
                file when the maximum number of files are currently open
                will fail.
                Additional information:
                Indicates the number of open files a personality (e.g. PCL or
                		PostScript) is guaranteed to be able to open before the file
                		system runs out of file handles. After writing this object, 
                		the printer must be rebooted (powercycled) before the change
                		takes effect. This object supports any value between 32 - 512
                		inclusive. If a value less then 32 then it snaps to 32 if 
                		greater than 512 it snaps to 512. The factory default value is 
                		depentdent on the amount of installed RAM. The default value of
                		32 is when Memory <= 4MB, 128 is if the memory is > 4MB.
                		Performing a cold reset sets this object back to the factory
                		default value. Returns status if attempting to access this 
                		object and there is no storage device is installed."
::= { settings-file-system 2 }
               
               
file-system-statistic-read-open OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The number of times the file system has received
                requests to open a file for reading.  Opening a file for
                both reading and writing will cause this value to
                change.  The POS should state if a power cycle causes
                the counter is be reset to zero.
                Additional information:
                Reset to the factory default value after a power cycle. 
                		Returns status if attempting to access this object and there is
                		no storage device installed. This value is increamented when a 
                		file is opened."
::= { status-file-system 1 }
               
               
file-system-statistic-write-open OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The number of times the file system has received
                requests to open a file for writing.  Opening a file for
                both reading and writing will cause this value to
                change.  The POS should state if a power cycle causes
                the counter is be reset to zero.
                Additional information:
                Reset to the factory default value after a power cycle. 
                		Returns status if attempting to access this object and there is
                		no storage device installed. This value is increamented when a 
                		file is opened."
::= { status-file-system 2 }
               
               
file-system-statistic-successful OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "A counter indicating the number of file system requests
                that completed successfully.  The POS should state if a
                power cycle causes the counter is be reset to zero.
                Additional information:
                Reset to the factory default value after a power cycle.
                		Returns status if attempting to access this object and there is
                		no storage device installed."
::= { status-file-system 3 }
               
               
file-system-statistic-unsuccessful OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "A counter indicating the number of file system requests
                that completed unsuccessfully.  The POS should state if
                a power cycle causes the counter is be reset to zero.
                Additional information:
                Reset to the factory default value after a power cycle. 
                		Returns status if attempting to access this object and there is
                		no storage device is installed."
::= { status-file-system 4 }
               
               
file-system-statistic-current-memory-usage OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "A value indicating the number of bytes of RAM currently
                used by the file system firmware.
                Additional information:
                Reset to the factory default value after a power cycle.
                		Returns status if attempting to access this object and there
                		is no storage device is installed. This will vary depending
                		on the number and size of msss storage devices installed."
::= { status-file-system 5 }
               
               
file-system-statistic-max-memory-usage OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "A value indicating the maximum number of bytes of RAM
                used by the file system firmware.  The POS should state
                if the value is reset to zero after a power cycle.
                Additional information:
                Resets to the factory default value after a power cycle.
                		Returns status if attempting to access this object and there 
                		is no storage device is installed."
::= { status-file-system 6 }
               
               
file-system2-initialize-volume OBJECT-TYPE
    SYNTAX  INTEGER {
		   eNotInitializing(1),
		   eInitializing(2)
		   }
    ACCESS  write-only
    STATUS  optional
    DESCRIPTION
                "Setting this object to eInitializing causes file system
                2 to be initialized.  Reading this object indicates if
                the file system is currently being initialized.
                Additional information:
                The hrDeviceIndex value for the mass storage device is 
                		the same value that is used to index into the FILE-SYSTEM 
                		sub-tree. Since this product supports only one storage device,
                		and since hrDeviceIndex for the mass storage devices will start
                		at 2 if the mass storage device is installed, the 
                		FILE-SYSTEM2-INITIALIZE-VOLUME object will be the object that 
                		allows the mass storage device to be installed."
::= { file-system2 6 }
               
               
error1-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error 1
                occurred.  Example time stamps include the actual time
                the error occurred (in seconds since Jan. 1, 1970), and
                the total engine page count.  The device POS documents
                the meaning of the time stamp.
                Additional information:
                In Color LaserJet8550 this item contains the engine  
                page count when the error occurred. A value of zero
                means 'no error'.  
                See ERROR1-CODE for an explanation of the order used 
                for storing errors."
::= { error1 1 }
               
               
error1-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                Contains a device specific error code.  A value 
                of zero means 'no error'. 
                			  
                			The error number is returned in the upper 16 bits. 
                			If it is 68,69,79, or 80, then the sub code is returned
                			in the lower 16 bits (eg. 68 0019, where the subcode is
                			already a hexadecimal value). 
                			If the error number is any other number, then the 1st 
                			sub code (XX) will be in bits 15-8 and the 2nd sub 
                			code (YY) will be in bits 7-0 (eg. 55.04.02) where 
                			XX=04 and YY=02).  
                			  
                			Example: If the error is 68 001A, then the value 
                			returned will be 4456474.  
                			To break it down: 4456474 = 0x0044001A  
                			The upper 16 bits: 0x0044 = 68  
                			The lower 16 bits: 0x001A = 001A
                			Which is the error: 68 001A  
                			  
                			Example: If the error is 55.04.241, then the error code
                			will be 3605745.  
                			To break it down: 3605745 = 0x003704F1  
                			The upper 16 bits: 0x0037 = 55  
                			The upper byte of the lower 16 bits: 0x04 = 04  
                			The lower byte of the lower 16 bits: 0xF1 = 241  
                			Which is the error: 55.04.241  
                			  
                			ERROR1- is the oldest error in the log. Errors are 
                			added until ERROR50- is reached. If more errors occur, 
                			ERROR1- is replaced by moving all error entries 
                			down one position and adding the newest error as 
                			ERROR50-"
::= { error1 2 }
               
               
error2-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error 2
                occurred.  Example time stamps include the actual time
                the error occurred (in seconds since Jan. 1, 1970), and
                the total engine page count.  The device POS documents
                the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error2 1 }
               
               
error2-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error2 2 }
               
               
error3-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error 3
                occurred.  Example time stamps include the actual time
                the error occurred (in seconds since Jan. 1, 1970), and
                the total engine page count.  The device POS documents
                the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error3 1 }
               
               
error3-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error3 2 }
               
               
error4-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error 4
                occurred.  Example time stamps include the actual time
                the error occurred (in seconds since Jan. 1, 1970), and
                the total engine page count.  The device POS documents
                the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error4 1 }
               
               
error4-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error4 2 }
               
               
error5-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error 5
                occurred.  Example time stamps include the actual time
                the error occurred (in seconds since Jan. 1, 1970), and
                the total engine page count.  The device POS documents
                the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error5 1 }
               
               
error5-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error5 2 }
               
               
error6-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error 6
                occurred.  Example time stamps include the actual time
                the error occurred (in seconds since Jan. 1, 1970), and
                the total engine page count.  The device POS documents
                the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error6 1 }
               
               
error6-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error6 2 }
               
               
error7-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error 7
                occurred.  Example time stamps include the actual time
                the error occurred (in seconds since Jan. 1, 1970), and
                the total engine page count.  The device POS documents
                the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error7 1 }
               
               
error7-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error7 2 }
               
               
error8-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error 8
                occurred.  Example time stamps include the actual time
                the error occurred (in seconds since Jan. 1, 1970), and
                the total engine page count.  The device POS documents
                the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error8 1 }
               
               
error8-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error8 2 }
               
               
error9-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error 9
                occurred.  Example time stamps include the actual time
                the error occurred (in seconds since Jan. 1, 1970), and
                the total engine page count.  The device POS documents
                the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error9 1 }
               
               
error9-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error9 2 }
               
               
error10-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                10 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error10 1 }
               
               
error10-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error10 2 }
               
               
error11-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                11 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error11 1 }
               
               
error11-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error11 2 }
               
               
error12-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                12 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error12 1 }
               
               
error12-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error12 2 }
               
               
error13-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                13 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error13 1 }
               
               
error13-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error13 2 }
               
               
error14-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                14 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error14 1 }
               
               
error14-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error14 2 }
               
               
error15-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                15 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error15 1 }
               
               
error15-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error15 2 }
               
               
error16-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                16 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error16 1 }
               
               
error16-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error16 2 }
               
               
error17-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                17 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error17 1 }
               
               
error17-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error17 2 }
               
               
error18-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                18 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error18 1 }
               
               
error18-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error18 2 }
               
               
error19-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                19 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error19 1 }
               
               
error19-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error19 2 }
               
               
error20-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                20 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error20 1 }
               
               
error20-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error20 2 }
               
               
error21-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                21 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error21 1 }
               
               
error21-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error21 2 }
               
               
error22-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                22 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error22 1 }
               
               
error22-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error22 2 }
               
               
error23-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                23 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error23 1 }
               
               
error23-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error23 2 }
               
               
error24-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                24 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error24 1 }
               
               
error24-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error24 2 }
               
               
error25-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                25 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error25 1 }
               
               
error25-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error25 2 }
               
               
error26-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                26 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error26 1 }
               
               
error26-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error26 2 }
               
               
error27-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                27 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error27 1 }
               
               
error27-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error27 2 }
               
               
error28-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                28 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error28 1 }
               
               
error28-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error28 2 }
               
               
error29-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                29 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error29 1 }
               
               
error29-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error29 2 }
               
               
error30-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                30 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error30 1 }
               
               
error30-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error30 2 }
               
               
error31-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                31 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error31 1 }
               
               
error31-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error31 2 }
               
               
error32-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                32 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error32 1 }
               
               
error32-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error32 2 }
               
               
error33-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                33 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error33 1 }
               
               
error33-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error33 2 }
               
               
error34-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                34 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error34 1 }
               
               
error34-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error34 2 }
               
               
error35-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                35 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error35 1 }
               
               
error35-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error35 2 }
               
               
error36-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                36 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error36 1 }
               
               
error36-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error36 2 }
               
               
error37-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                37 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error37 1 }
               
               
error37-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error37 2 }
               
               
error38-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                38 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error38 1 }
               
               
error38-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error38 2 }
               
               
error39-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                39 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error39 1 }
               
               
error39-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error39 2 }
               
               
error40-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                40 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error40 1 }
               
               
error40-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error40 2 }
               
               
error41-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                41 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error41 1 }
               
               
error41-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error41 2 }
               
               
error42-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                42 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error42 1 }
               
               
error42-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error42 2 }
               
               
error43-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                43 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error43 1 }
               
               
error43-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error43 2 }
               
               
error44-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                44 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error44 1 }
               
               
error44-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error44 2 }
               
               
error45-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                45 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error45 1 }
               
               
error45-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error45 2 }
               
               
error46-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                46 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error46 1 }
               
               
error46-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error46 2 }
               
               
error47-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                47 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error47 1 }
               
               
error47-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error47 2 }
               
               
error48-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                48 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error48 1 }
               
               
error48-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error48 2 }
               
               
error49-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                49 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error49 1 }
               
               
error49-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error49 2 }
               
               
error50-time-stamp OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains some sort of time stamp indicating when error
                50 occurred.  Example time stamps include the actual
                time the error occurred (in seconds since Jan. 1, 1970),
                and the total engine page count.  The device POS
                documents the meaning of the time stamp.
                Additional information:
                See ERROR1-TIME-STAMP."
::= { error50 1 }
               
               
error50-code OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Contains a device specific error code.  Each device POS
                should list what errors are logged to the error log and
                the meaning of each supported error code value.
                Additional information:
                See ERROR1-CODE."
::= { error50 2 }
               
               
rpc-test-return-code OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  write-only
    STATUS  optional
    DESCRIPTION
                "This test object that will not be supported in any
                released product.  Setting this object allows the next
                RPC call return code to be specified.  The POS will
                specify the binary format.
                Additional information:
                The format of the binary data is a one of three formats.
                	The first format is no binary data, which indicates the next RPC
                	reply should not be modified. The other two formats are described
                	in RFC 1057 and encoded using XDR (i.e.e, the value is the data 
                	used to instead of the actual RPC reply). The second format is 
                	when reply_stat is MSG_ACCEPTED and accept_stat is something other
                	than SUCCESS. The third format is when reply_stat is MSG_DENIED.
                	Notice that all RPC replies that do not contain any 'results' 
                	are supported."
::= { settings-rpc 1 }
               
               
rpc-bind-protocol-address OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Array of Berkeley sockets style protocol addresses used
                to bind RPC to a communications protocol family.
                Setting an instance of this array object to a zero
                length binary value disables the transport protocol
                indicated by that instance.  All multi-bytes fields are
                in network (or big-endian) order.  Bytes 1 and 2
                indicate the transport protocol.  Some of the transport
                protocol mapping information can be found in RFC 1010
                Assigned Numbers.  A list of interesting transport
                protocol number mappings include:  
                Protocol | Number   
                ---------+-------   
                 UDP/IP  |  17   
                  IPX    |  1000   
                  MLC    |  4660   
                Bytes 3 and 4 indicate the address family.  The address
                family uses the same mapping as the BSD sockets address
                family.  A list of interesting address family mappings
                include:  
                Address Family | Number   
                ---------------+-------   
                    Internet   |   2   
                    NetWare    |   6   
                    MLC        | 22136   
                The format the fifth and following bytes is dependent on
                the address family.  For the Internet address family,
                bytes 5 and 6 contain the port number, bytes 7 through
                10 contain the IP address, and the following eight bytes
                are unused.  For NetWare, bytes 5 through 8 are the
                network number, bytes 9 through 14 are the node number,
                and bytes 15 and 16 are the socket number.
                Additional information:
                The length of the binary value is zero if the instance of an
                	object in the rpc-bind-protocol-address array is not in use.
                	An unfortuante side effect of the implementation is initializing
                	the mass storage device sets this object back to the factory 
                	default value. Returns <noSuchName> status if
                	attempting to access this object and there is no storage device
                	is installed."
::= { settings-rpc 2 }
               
               
rpc-statistic-successful OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "A counter indicating the number of RPC requests that
                completed successfully (reply_data stat is SUCCESS).
                The POS should state if a power cycle causes the counter
                is be reset to zero.
                Additional information:
                Reset to the factory default value after a power cycle.
                		Returns <noSuchName> status if
                		attempting to access this object and there is no storage
                		device is installed."
::= { status-rpc 1 }
               
               
rpc-statistic-unsuccessful OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "A counter indicating the number of RPC requests that
                completed unsuccessfully (reply_data stat is not
                SUCCESS).  The POS should state if a power cycle causes
                the counter is be reset to zero.
                Additional information:
                Reset to the factory default value after a power cycle.
                		Returns <noSuchName> status if
                		attempting to access this object and there is no storage
                		device is installed."
::= { status-rpc 2 }
               
               
rpc-bound-protocol-address OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "An array of Berkeley sockets style protocol addresses
                that the NFS service has been bound to successful.  The
                format is that same as the array of RPC-BIND-PROTOCOL-
                ADDRESS of objects.
                Additional information:
                Returns <noSuchName> status if
                	attempting to access this object and there is no storage device
                	is installed."
::= { status-rpc 3 }
               
               
nfs-server-memory OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The amount of memory, in bytes, used by the Network File
                System server to buffer file data.
                Additional information:
                Roports the amount of memoyr, in bytes, reserved for use by the
                	NFS server. An unfortunate side effect of the implementation is 
                	initializing the mass storage device sets this object back to the 
                	factory default value. Also includes the memory used by other 
                	firmware components in addition to the NFS server. Returns 
                	<noSuchName> status if attempting to access this 
                	object and there is no storage device is installed."
::= { settings-nfs-server 1 }
               
               
nfs-server-read-size OBJECT-TYPE
    SYNTAX  INTEGER(256..1500)
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "The maximum amount of data transferred in one NFS server
                read data call.
                Additional information:
                An unfortunate side effect of the implementation is 
                		initializing the mass storage device sets this object back to 
                		the factory default value. Returns status if attempting to
                		access this object and there is no storage device is installed.
                		Rebooting causes this value to reset to factory default. 
                		Value < 256 snaps to 256 value > 1500 snaps to 1500."
::= { settings-nfs-server 2 }
               
               
nfs-server-write-size OBJECT-TYPE
    SYNTAX  INTEGER(256..1500)
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "The maximum amount of data transferred in one NFS server
                write data call.
                Additional information:
                An unfortunate side effect of the implementation is 
                		initializing the mass storage device sets this object bact to 
                		the factory default value. Returns status if attempting to 
                		access this object and there is no storage device installed."
::= { settings-nfs-server 3 }
               
               
nfs-server-test-return-code OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  write-only
    STATUS  optional
    DESCRIPTION
                "This test object that will not be supported in any
                released product.  Setting this object allows the next
                NFS call return code to be specified.  The POS will
                specify the binary format.
                Additional information:
                A three byte binary value. The first byte indicates what 
                	procedure is being effected by this set.  
                	value | function  
                	------+------------------  
                	  1   | GetAttr  
                	  2   | SetAttr  
                	  3   | reserved  
                	  4   | Lookup  
                	  5   | reserved  
                	  6   | Read  
                	  7   | reserved  
                	  8   | Write  
                	  9   | Create  
                	  10  | Remove  
                	  11  | Rename  
                	  12  | reserved  
                	  13  | reserved  
                	  14  | MkDir  
                	  15  | RmDir  
                	  16  | ReadDir  
                	  17  | StatFS  
                	The second byte is the stat value returned by the next call to 
                	procedure specified by the value of the first byte. The second
                	byte can not be zero. Refer to RFC 1094 for a list of stat values.
                	The third byte indicates which call to the specified file system
                	routine will fail. A value of one means the first call will fail.
                	A value of two means the second call will fail, and so on. 
                	Writing this boject causes any previous write to this boject to 
                	be invalidated."
::= { settings-nfs-server 4 }
               
               
nfs-server-statistic-successful OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "A counter indicating the number of NFS requests that
                completed without error.  The POS should state if a
                power cycle causes the counter is be reset to zero.
                Additional information:
                Reset to the factory default value after a power cycle.
                		Returns status if attempting to access this object and there
                		is no storage device installed."
::= { status-nfs-server 1 }
               
               
nfs-server-statistic-unsuccessful OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "A counter indicating the number of NFS requests that
                completed with an NFS status other than NFS_OK (0).  The
                POS should state if a power cycle causes the counter is
                be reset to zero.
                Additional information:
                Reset to the factory default value after a power cycle.
                		Returns status if attempting to access this object and there
                		is no storage device installed."
::= { status-nfs-server 2 }
               
               
nfs-server-statistic-current-memory-usage OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "A value indicating the number of bytes of RAM currently
                used by the NFS firmware.
                Additional information:
                Resets to the factory default value after a power cycle.
                		Returns status if attempting to access this object and there
                		is no storage device is installed."
::= { status-nfs-server 4 }
               
               
nfs-server-statistic-max-memory-usage OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "A value indicating the maximum number of bytes of RAM
                used by the NFS firmware.  The POS should state if the
                value is reset to zero after a power cycle.
                Additional information:
                Resets to the factory default value after a power cycle.
                		Returns status if attempting to access this object and there
                		is no storage device is installed."
::= { status-nfs-server 5 }
               
               
rpc-bind-test-return-code OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  write-only
    STATUS  optional
    DESCRIPTION
                "This test object that will not be supported in any
                released product.  Setting this object allows the next
                RPC bind call return code to be specified.  The POS will
                specify the binary format.
                Additional information:
                A one byte value.  
                	value | meaning  
                	------+-----------------------  
                	  1   | Next GetPort or GetAddr will receive port 0  
                	      | (indicating the service is not supported).  
                	  2   | Next Dump will receive an empty table."
::= { settings-rpc-bind 1 }
               
               
rpc-bind-statistic-successful OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "A counter indicating the number of RPC bind (RPC program
                number 100000, version 2) requests that completed
                successfully.  The POS should state if a power cycle
                causes the counter is be reset to zero.
                Additional information:
                Reset to the factory default value after a power cycle.
                		Returns <noSuchName> status if
                		attempting to access this object and there is no storage
                		device is installed."
::= { status-rpc-bind 1 }
               
               
rpc-bind-statistic-unsuccessful OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "A counter indicating the number of RPC bind (RPC program
                number 100000, version 2) requests that completed
                unsuccessfully.  The POS should state if a power cycle
                causes the counter is be reset to zero.
                Additional information:
                Reset to the factory default value after a power cycle.
                		Returns <noSuchName> status if
                		attempting to access this object and there is no storage
                		device is installed."
::= { status-rpc-bind 2 }
               
               
xip-statistic-processed OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "A counter indicating the number of XIP requests that
                were processed.  The POS should state if a power cycle
                causes the counter is be reset to zero.
                Additional information:
                The number of XIP datagrams that have been received by the
                	XIP service. Reset to the factory default value after a power cycle.
                	Returns <noSuchName> status if
                	attempting to access this object and there is no storage device
                	is installed."
::= { status-xip 1 }
               
               
xip-statistic-data-in-dropped OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "A counter indicating the number of XIP data in datagrams
                that were dropped (typically due to the printer being
                flooded with XIP requests ).  The POS should state if a
                power cycle causes the counter is be reset to zero.
                Additional information:
                Reset to the factory default value after a power cycle.
                	Returns <noSuchName> status if
                	attempting to access this object and there is no storage device
                	is installed."
::= { status-xip 2 }
               
               
io-timeout OBJECT-TYPE
    SYNTAX  INTEGER(5..300)
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "The amount of time, in seconds, to wait for more print
                job data to be received before an I/O timeout occurs.
                The I/O channel being timed is the I/O channel that
                received the data associated with the current print job.
                If an I/O timeout occurs, the PDL processing sub-system
                assumes all the data associated with the current print
                job has been received, and processes the end of job in
                an PDL specific manner.  The POS specifies the supported
                values.
                Additional information:
                If an I/O timeout occurs, the PDL processing 
                			sub-system will consider it an end of job condition 
                			only if there is data from another I/O subsystem 
                			waiting to be processed.  
                			The suppurted values are 5 to 300 seconds and 
                			the step size is 10 seconds. 
                Setting to a value outside the supported range returns 
                <badValue> status and the value
                			will be snapped to the nearest supported value."
::= { settings-io 1 }
               
               
io-switch OBJECT-TYPE
    SYNTAX  INTEGER {
		   eYes(1)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Indicates if the device will switch between I/O channels
                when a job boundary is encountered and print job data is
                available on another I/O channel."
::= { settings-io 2 }
               
               
io-buffering OBJECT-TYPE
    SYNTAX  INTEGER {
		   eAuto(3)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns or controls the manner in which the device
                performs I/O data buffering.  I/O data buffering allows
                additional print job data to be buffered by the I/O sub-
                system in an effort to allow the computer sending the
                data to perform other tasks and to keep the PDL
                processing sub-system busy.  eOff, I/O buffering is
                disabled.  When eOn, I/O buffering is enabled and the
                IO-BUFFER-SIZE object controls the amount of memory set
                aside for I/O buffer.  When eAuto, I/O buffering is
                enabled and the I/O buffer size is determined
                automatically by the device and the IO-BUFFER-SIZE
                object is not used.
                Additional information:
                When eAuto, I/O buffering is enabled and the I/O 
                		buffer size is determined automatically by the device and 
                		the IO-BUFFER-SIZE object is not used."
::= { settings-io 5 }
               
               
io-buffer-size OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns or configures the amount of memory, in bytes,
                dedicated to I/O print job data buffering.  Attempting
                to set to an unsupported value causes the device to use
                the closest supported value.  Each device POS should
                document the list of supported values.
                Additional information:
                 When IO-BUFFERING is eAuto, the printer determines 
                		the value of this object. Reading this object when 
                		IO-BUFFERING is eAuto will return the value that is currently 
                		being used by the printer.  
                		The minimum value is 10240; the maximum value is the current 
                		value of this object plus the value of 
                		MAXIMUM-IO-BUFFERING-MEMORY. Supported values are multiples of 
                		10240 for values less or equal to 97280 and multiples of 102400
                		for values greater than 97280. "
::= { settings-io 6 }
               
               
maximum-io-buffering-memory OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "This object's name is misleading.  Returns the maximum
                amount of additional memory, in bytes, that can be
                dedicated to buffering print job data.
                Additional information:
                Memory for I/O Buffering is allocated in increments of 
                		102400 bytes. Therefore, for each 1M (1048576 bytes) of memory 
                		added to the printer, 1024000 bytes are made available to 
                		resource saving (and I/O buffering) and 24576 bytes are 
                		retained until an additional 102400 byte block can be made 
                		available. The value reported by this object is always 
                		rounded down to the nearest multiple of 102400."
::= { settings-io 7 }
               
               
port1-parallel-speed OBJECT-TYPE
    SYNTAX  INTEGER {
		   eFast(2)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns or changes the maximum parallel I/O port speed,
                for port 1.  This object is only supported if this port
                is a parallel port.  An eSlow setting causes a 10 us
                busy pulse per received byte of data.  An eFast setting
                causes a 1.5 us busy pulse per received byte of data.
                In rare cases, setting this value to eFast can cause the
                parallel port to no longer transfer data reliably.
                Additional information:
                Returns the maximum parallel I/O port speed, 
                		for port 1. This object is only supported if this port 
                		is a parallel port. An eFast setting causes a 1.5 us
                		busy pulse per received byte of data. In rare cases, 
                		eFast can cause the parallel port to no longer transfer 
                		data reliably. "
::= { port1 4 }
               
               
port1-parallel-bidirectionality OBJECT-TYPE
    SYNTAX  INTEGER {
		   eBidirectional(2)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns or changes whether the parallel I/O port
                supports bidirectional communication for port 1.  This
                object is only supported if this port is a parallel
                port.
                Additional information:
                Color LaserJet8550 will always be bi-directional. Thus, having
                		this object here doesn't mean much... 
                		A get on this object returns the current mode for the parallel 
                		port."
::= { port1 5 }
               
               
default-copies OBJECT-TYPE
    SYNTAX  INTEGER(1..999)
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Returns or changes default copies.  Default copies is
                the default values used by the PDL to control the number
                of copies of each page in the print job that are
                printed.  The print job can override this value.  The
                list of supported values should be documented in the
                device POS.
                Additional information:
                 The supported values are 1 
                through 999. Setting to an unsupported value causes  
                the printer to substitute in a snap value  
                and to return  
                <noError> status.  
                The snap values are as follow:  
                <1 snaps to 1  
                >999 snaps to 999"
::= { settings-pdl 4 }
               
               
resource-saving OBJECT-TYPE
    SYNTAX  INTEGER {
		   eAuto(3)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns or changes PDL resource saving.  Resource saving
                stores a PDL's permanent soft resources, like fonts,
                even when another PDL is active.  Resource saving is
                also called environment saving.  When eOff, resource
                saving is disabled.  When ON, resource saving is enabled
                and memory is set aside for each PDL based on that PDL's
                resource saving memory size object, to store that PDL's
                permanent soft resources.  When eAuto, resource saving
                is enabled and memory space for each installed PDL is
                determined automatically.  The device POS should
                document what values are legal when only one PDL is
                installed.
                Additional information:
                Color LaserJet8550 only supports eAuto. Thus memory space for
                			each installed PDL is determined automatically."
::= { settings-pdl 6 }
               
               
maximum-resource-saving-memory OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "This object's name is misleading.  This object returns
                the maximum amount of additional memory, in bytes, that
                can be dedicated to holding PDL permanent soft
                resources.
                Additional information:
                Base memory for Color LaserJet8550 is 32MB.   
                			Memories for PostScript and PCL are 3MB and 4MB 
                			respectively. However, for every 8MB increment, 
                			0.5MB is added to each PDL.
                			(((64 * 8) - 32) / 8) / 0.5 = 30MB.
                			Thus, total memories for PostScript and PCL are 33MB
                			and 34MB respectively."
::= { settings-pdl 7 }
               
               
default-vertical-black-resolution OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Returns or changes the value of the default vertical
                black resolution.  The units are dots per inch.
                Additional information:
                In Color LaserJet8550 changing this OID also causes
                			DEFAULT-HORIZONTAL-BLACK-RESOLUTION to change.
                			DEFAULT-HORIZONTAL-BLACK-RESOLUTION and
                			DEFAULT-VERTICAL-BLACK-RESOLUTION must always be
                			the same. The supported value is 600.
                			Setting to an unsupported value causes the printer
                			to substitute in a snap value and to return
                			<noError> status.  
                			< 300 snap to 600  
                			>= 300 snap to 600"
::= { settings-pdl 8 }
               
               
default-horizontal-black-resolution OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Returns or changes the value of the default horizontal
                black resolution.  The units are dots per inch.
                Additional information:
                In Color LaserJet8550 changing this OID also causes  
                DEFAULT- VERTICAL-BLACK RESOLUTION to change.   
                DEFAULT- HORIZONTAL-BLACK-RESOLUTION and 
                DEFAULT-VERTICAL-BLACK-RESOLUTION must always be the  
                same.  The supported value is 600.
                Setting to an unsupported value causes the printer 
                to substitute in a snap value and to 
                return <noError> status.  
                The snap values are as follow:  
                < 300 snap to 600  
                >= 300 snap to 600"
::= { settings-pdl 9 }
               
               
default-page-protect OBJECT-TYPE
    SYNTAX  INTEGER {
		   eAuto(3)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns or changes the default page protection behavior.
                If eOff, the device does not reserve memory for holding
                the entire raster form of a processed page.  If eOn,
                then memory is reserved.  If eAuto, the device
                determines the amount of memory to reserve.
                Additional information:
                In eAuto, the device determines the amount of 
                			memory to reserve.
                			Color LaserJet8550 doesn't need to support this object. 
                			Thus, this object being here does not convey
                			much meaning."
::= { settings-pdl 10 }
               
               
default-lines-per-page OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Returns or changes the default number of lines per page.
                The POS indicates the supported values.  An unsupported
                value causes the printer to use the closest supported
                value, causing the printer to return the
                <noError>.
                Additional information:
                The supported values in Color LaserJet8550 are 5 to 128. 
                Setting to an unsupported value causes the  
                the printer to substitute in a snap value and to return 
                			<noError> status.  
                The snap values are as follow:  
                <5 snaps to 5  
                >128 snaps to 128"
::= { settings-pdl 11 }
               
               
default-vmi OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Returns or changes the default vertical motion index.
                The unit of measure for VMI is centipoints per line.
                The POS indicates the supported values.  An unsupported
                value causes the printer to use the closest supported
                value, causing the printer to return
                <noError>."
::= { settings-pdl 12 }
               
               
default-media-size OBJECT-TYPE
    SYNTAX  INTEGER {
		   eUSExecutive(1),
		   eUSLetter(2),
		   eUSLegal(3),
		   eLedger(11),
		   eISOandJISA5(25),
		   eISOandJISA4(26),
		   eISOandJISA3(27),
		   eJISB5(45),
		   eJISB4(46),
		   eJapanesePostcardDouble(72),
		   eMonarch(80),
		   eCommercial10(81),
		   eInternationalDL(90),
		   eInternationalC5(91),
		   eInternationalB5(100)
		   }
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "This indicates the default media size.  A write of an
                unsupported value causes an <badValue>.
  Complete list of supported media sizes along
                with their dimensions are listed in the ''Media Size
                Table'' near the end of this document."
::= { settings-pdl 13 }
               
               
cold-reset-media-size OBJECT-TYPE
    SYNTAX  INTEGER {
		   eUSLetter(2),
		   eISOandJISA4(26)
		   }
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Returns or sets the media size that is used as the
                DEFAULT-MEDIA-SIZE when a cold reset occurs."
::= { settings-pdl 19 }
               
               
default-media-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Returns or sets the media name that is used until the
                media name is changed by a print job command.
                Additional information:
                This string must be one of the 
                			MEDIAn-NAME objects."
::= { settings-pdl 22 }
               
               
form-feed-needed OBJECT-TYPE
    SYNTAX  INTEGER {
		   eFalse(1)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Indicates if the PDL processing sub-system has made
                marks on the current page and the source subsystem has
                been idle for a device specific amount of time.
                Additional information:
                This object in Color LaserJet8550 will never go to true."
::= { status-pdl 2 }
               
               
pcl-resource-saving-memory-size OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns or changes the amount of resource saving memory
                set aside to hold permanent soft PCL resources.
                Additional information:
                The value returned by this object is the amount of 
                		Resource Saving memory currently dedicated to PCL.  
                		If a value is received that is between 1 and 409599, it will be
                		snapped to 409600 and a status of 
                		<noError> returned. 
                		If an unsupported value greater than 409600 is received,
                		it will be snapped down to the nearest 102400 value 
                		and a status of <noError> returned."
::= { pdl-pcl 2 }
               
               
pcl-total-page-count OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Total number of PCL pages printed by the device.
                Additional information:
                In Color LaserJet8550 the PCL page count is kept in NVRAM 
                			however the NVRAM value is only updated every 
                			10 pages.  
                			NOTE: The value returned by this OID will be
                incremented every page but if power is lost between
                NVRAM updates, up to 9 pages of the page count may be
                lost. The page count counter will be reset to zero
                after 16,777,215 (2^24-1) pages.  
                			The page count is incremented when a sheet of media is 
                			pulled from an input tray. A duplex printed sheet will 
                			cause this counter to be incremented by two."
::= { pdl-pcl 5 }
               
               
pcl-default-font-height OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Returns or changes the default PCL height.  Height is an
                approximate measure of the body of the type in
                centipoints.  A centipoint is 1/7200 inch.  Height
                applies only to proportional fonts.  Point size, in
                points, can be converted to font height, in centipoints,
                by multiplying the point size by 100.  The POS indicates
                the supported values.  An unsupported value causes the
                printer to use the closest supported value, causing the
                printer to return <noError>.
                ''Closest'' means the smallest absolute difference.
                Additional information:
                Supported values range from 400 to 99975, in
                			increments of 25 units.
                			Setting to an unsupported value causes the 
                			printer to substitute in a snap value and to 
                return <noError> status.  
                The snap values are as follow:  
                <=400 snaps to 400  
                >=99975 snaps to 99975  
                Unsupported values in the range 400 to 99975 snaps  
                DOWN to the previous supported value 
                (i.e 25293 snaps to 25275 or 75038 snaps to 75025)."
::= { pdl-pcl 13 }
               
               
pcl-default-font-source OBJECT-TYPE
    SYNTAX  INTEGER {
		   eInternal(1),
		   ePermanentSoft(2),
		   eRomSimm1(10),
		   eRomSimm2(11),
		   eRomSimm3(12),
		   eRomSimm4(13)
		   }
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Returns or changes the value of the default font source
                variable in NVRAM."
::= { pdl-pcl 14 }
               
               
pcl-default-font-number OBJECT-TYPE
    SYNTAX  INTEGER(0..999)
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Returns or changes the value of the default font number
                variable in NVRAM.  Writing an unsupported value causes
                the printer to generate an
                <badValue>."
::= { pdl-pcl 15 }
               
               
pcl-default-font-width OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Returns or changes the default PCL font width.  Width is
                expressed as the width of a character in centipoints.  A
                centipoint is 1/7200 inch.  Width applies only to fixed
                space fonts.  Pitch, in character per inch, can be
                converted to font width, in centipoints, by dividing
                7200 by the pitch.  The POS indicates the supported
                values.  An unsupported value causes the printer to use
                the closest supported value, causing the printer to
                return <noError>.  ''Closest''
                means the smallest absolute difference.
                Additional information:
                Setting to an unsupported value causes the 
                			printer to substitute in a snap value (listed below) 
                			and to return <noError> status.
                The snap values are as follow:  
                <=44 snaps to 44  
                >=9999 snaps to 9999"
::= { pdl-pcl 16 }
               
               
postscript-resource-saving-memory-size OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns or changes the amount of resource saving memory
                set aside to hold permanent soft PostScript resources.
                Additional information:
                The value returned by this object is the amount of 
                		Resource Saving memory currently dedicated to PostScript. 
                		If a value is received that is between 1 and 409599, it will 
                		be snapped to 409600 and a status of 
                		<noError> returned. 
                		If an unsupported value greater than 409600 is received,
                		it will be snapped down to the nearest 102400 value 
                		and a status of <noError> returned."
::= { pdl-postscript 2 }
               
               
postscript-total-page-count OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Total number of PostScript pages printed by the device.
                Additional information:
                 In Color LaserJet8550 the count is kept in NVRAM however the 
                			NVRAM value is only updated every 10 sheets.  
                			NOTE: The value returned by this OID will be 
                incremented every sheet but if power is lost between 
                NVRAM updates up to 9 sheets of the count may be 
                lost.  The counter will be reset to zero 
                after 16,777,215 (2^24-1) pages. "
::= { pdl-postscript 5 }
               
               
postscript-print-errors OBJECT-TYPE
    SYNTAX  INTEGER {
		   eOff(1),
		   eOn(2)
		   }
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Returns or changes the value of the print PostScript
                errors setting.  If eOn, PostScript prints an error page
                showing the error encountered and the stack at the time
                of the error."
::= { pdl-postscript 11 }
               
               
postscript-jam-recovery OBJECT-TYPE
    SYNTAX  INTEGER {
		   eOn(2)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns or changes the PostScript jam recovery setting.
                If eOn, then the device will reprint PostScript pages,
                if those pages jam.
                Additional information:
                Returns the Postscript jam recovery setting. 
                			If eOn, then the device will reprint PostScript pages, 
                			if those pages jam."
::= { pdl-postscript 12 }
               
               
pjl-password OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns PJL password, if the password is not set (zero).
                If the password is set, then attempting to retrieve the
                password causes an <genErr> to occur
                and will return the <NullValue>."
::= { pjl 1 }
               
               
jetsend-mode OBJECT-TYPE
    SYNTAX  INTEGER {
		   eOff(1),
		   eOn(2)
		   }
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Enables or disables the JetSend processing sub-system.
                Additional information:
                Enables or disables the JetSend processing subsystem. 
                		The valid values are eOff and eOn. 
                		(Specifying an invalid mode causes an
                		<badValue> error to be returned.)"
::= { settings-jetsend 1 }
               
               
jetsend-contact-password OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(16))
    ACCESS  write-only
    STATUS  optional
    DESCRIPTION
                "A C structure containing the following fields:
                 typedef struct {
                     ubyte old_password[8];
                     ubyte new_password[8];/
                 } jetsend_change_contact_password_t;
                where ubyte is an unsigned byte (0-255).
                Additional information:
                Controls access to the JetSend processing subsystem. 
                		Password absence/presence determines whether the device 
                		will allow a session to be established. The following C 
                		data structure contains the relevant fields (described in 
                		subsequent paragraphs):  
                		typedef struct {   
                		unsigned char old_password[8];   
                		unsigned char new_password[8]; }  
                		Whenever the password is disabled (i.e., is zero-filled 
                		for its entire length), the device is indicating its 
                		willingness to allow session establishment. Whenever the 
                		password is enabled (i.e., has one or more non-zero-filled 
                		values), the device is controlling session establishment -- 
                		all in-progress JetSend sessions must supply a matching 
                		password or the device will reject the in-progress session. 
                		To disable the password, specify the matching password via the 
                		'old_password' field and zero-fill the 'new_password' field.  
                		To enable the password for the first time, zero-fill the 
                		'old_password' field and specify the new password via the 
                		'new_password' field (the new password should not be 
                		zero-filled; otherwise, the password will remain disabled). 
                		To enable or change the password thereafter, specify the 
                		matching password via the 'old_password' field and specify 
                		the new password via the 'new_password' field (the new desired 
                		password should not be zero-filled; otherwise, the password 
                		will be disabled).   
                		To determine if the password is enabled, zero-fill both the 
                		'old_password' and 'new_password' fields. If an error occurs, 
                		the password is enabled; otherwise, the password is disabled. 
                		(Specifying either an 'old_password' or 'new_password' fields 
                		greater than eight (8) bytes causes the error  
                		<badValue> to be returned.)"
::= { settings-jetsend-contact 1 }
               
               
jetsend-contact-ip-address-security OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(16))
    ACCESS  write-only
    STATUS  optional
    DESCRIPTION
                "A C structure containing the following fields:
                 typedef struct {
                     ubyte reserved[3];
                     ubyte command; /* command: 0 to 1 */
                     ubyte password[8];
                     ubyte IPAddress[4];
                 } jetsend_contact_ip_address_security_t;
                where ubyte is an unsigned byte (0-255).  The defined
                values defined for command are:  
                  
                When command is 0:  
                  IPAddress is 0:  device is locked, no one can contact
                it  
                  IPAddress is > 0:  only that address is allowed to
                contact the device  
                  
                When command is 1:  
                  IPAddress is 0:  any device can contact it  
                  IPAddress is > 0:  any device matching this mask can
                contact it.  If the result of logically anding the mask
                value supplied in the IPAddress field with the sending
                device's IP address matches the result of logically
                anding the mask value supplied in the IPAddress field
                with this device's IP address, then JetSend will allow
                the session to be established.
                Additional information:
                Controls the device or class of device(s) which may 
                		communicate with the JetSend processing subsystem. 
                		The following C data structure contains the relevant fields 
                		(described in subsequent paragraphs):  
                		typedef struct {   
                		unsigned char reserved[3];   
                		unsigned char command;   
                		unsigned char password[8];   
                		unsigned char IPAddress[4]; }   
                		The 'reserved' field is not used and should remain zero-filled.
                		  
                		The 'command' field interpretation differs based on its value: 
                		0 = Accept session(s) only from the specific device whose IP 
                		address matches the specified IP address; all other session 
                		request(s) from non-matching device(s) are rejected. 1 = Accept
                		session(s) only from the specific device(s) whose IP 
                		address(es) conform to the mask specified in the 'IPAddress' 
                		field; all other session request(s) from device(s) with 
                		non-matching submask(s) are rejected. (If the result of 
                		logically AND'ing the mask value supplied in the 'IPAddress' 
                		field with the sending device's IP address matches the result 
                		of logically AND'ing the mask value supplied in the 'IPAddress'
                		field with this device's IP address, then JetSend will allow 
                		session establishment.   
                		Password absence/presence determines whether the device will 
                		allow the caller to alter the IP address security. 
                		If the password is disabled, the caller may set the 'command' 
                		and 'IPAddress' fields directly. If the password is enabled, 
                		the caller may (re-)set the 'command' and 'IPAddress' fields 
                		only after specifying the matching 'password' field. (Refer to 
                		the aforementioned 'JETSEND-CONTACT-PASSWORD' object ID.) 
                		(Specifying either an invalid 'command' field value or a 
                		'password' field greater than eight (8) bytes or an 'IPAddress'
                		field greater than four (4) bytes causes the error 
                		<badValue> to be returned.)"
::= { settings-jetsend-contact 2 }
               
               
total-color-page-count OBJECT-TYPE
    SYNTAX  INTEGER(0..4294967296)
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Total number of color pages printed by the device.
                Additional information:
                Any page with one or more color pixels is counted as 
                		a color page. Pages that only contain black marks are not
                		counted by this object.  
                		The counter will roll over to zero after 4,294,967,296 pages.  
                		Each side of a duplexed sheet of media will be counted 
                		independently based on the criteria listed above."
::= { status-prt-eng 7 }
               
               
duplex-page-count OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Total number of sheets of media that have been duplex
                printed.  A sheet is counted if it travels through the
                duplex page path, regardless of whether or not marks are
                made on the page.  The POS will indicate if the value is
                kept in NVRAM.
                Additional information:
                In Color LaserJet8550 the count is kept in 
                NVRAM however the NVRAM value is only updated every 10 
                sheets.  NOTE: The value returned by this OID will be 
                incremented every sheet but if power is lost between 
                NVRAM updates up to 9 sheets of the count may be 
                lost.  The counter will be reset to zero 
                after 16,777,215 (2^24-1) pages. "
::= { status-prt-eng 22 }
               
               
mp-tray OBJECT-TYPE
    SYNTAX  INTEGER {
		   eCassette(2),
		   eFirst(3)
		   }
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Returns or changes the value of the multi-purpose (MP)
                tray configuration variable.  The MP tray can be
                configured to operate as an additional input tray
                (eCassette), a manual feed slot (eManual), or in a
                manner compatible with the LaserJet III manual feed slot
                (eFirst).  If configured for eFirst, if media is present
                in the MP tray, that media is used (assuming the size
                matches and the print job didn't specify another tray)
                until the MP tray is empty."
::= { settings-intray 5 }
               
               
custom-paper-dim-unit OBJECT-TYPE
    SYNTAX  INTEGER {
		   eTenThousandthsOfInches(3),
		   eMicrometers(4)
		   }
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "The units of measure used to specify the width and
                height of the printer's custom paper.  The unit of
                measure of eTenThousandthsOfInches is 0.0001 inches.
                Additional information:
                The only valid values for this object are 
                		eTenThousandthsOfInches (3), and eMicrometers (4). 
                		The data for this object is stored in NVRAM."
::= { settings-intray 7 }
               
               
custom-paper-feed-dim OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Sets the printer's custom paper dimension in the feed
                direction (direction parallel to the direction of paper
                feeding).  The value for this object is specified in
                micrometers or tenthousandths of an inch, depending upon
                the value of CUSTOM-PAPER-DIM-UNIT.  The valid range is
                engine-dependent and should be documented in the POS for
                each product.
                Additional information:
                The valid range for Color LaserJet8550 is 75000 to 177000 if
                		CUSTOM-PAPER-DIM-UNIT is eTenthousandthoOfInches or
                		190500 to 449580 if CUSTOM-APPER-DIM-UNIT is
                		eMicrometers. Attempts to set this object outside the valid
                		range will result in a return value of 
                		<badValue>. The data for this object
                		is stored in NVRAM."
::= { settings-intray 8 }
               
               
custom-paper-xfeed-dim OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Sets the printer's custom paper dimension in the cross-
                feed direction (direction ninety degrees relative to the
                direction of paper feeding).  The value for this object
                is specified in micrometers or tenthousandths of an
                inch, depending upon the value of CUSTOM-PAPER-DIM-UNIT.
                The valid range is engine-dependent and should be
                documented in the POS for each product.
                Additional information:
                The valid range for Color LaserJet8550 is 36700 to 117000 if
                		CUSTOM-PAPER-DIM-UNIT is eTenthousandthoOfInches or
                		93218 to 297180 if CUSTOM-APPER-DIM-UNIT is
                		eMicrometers. Attempts to set this object outside the valid
                		range will result in a return value of 
                		<badValue>. The data for this object
                		is stored in NVRAM."
::= { settings-intray 9 }
               
               
tray1-media-size-loaded OBJECT-TYPE
    SYNTAX  INTEGER {
		   eUSExecutive(1),
		   eUSLetter(2),
		   eUSLegal(3),
		   eLedger(11),
		   eISOandJISA5(25),
		   eISOandJISA4(26),
		   eISOandJISA3(27),
		   eJISB5(45),
		   eJISB4(46),
		   eJapansePostcardDouble(72),
		   eMonarch(80),
		   eCommercial10(81),
		   eInternationalDL(90),
		   eInternationalC5(91),
		   eInternationalB5(100),
		   eCustom(101)
		   }
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Returns the media size that is currently
                configuredconfigured in tray #1.  This object can be set
                to indicate the media size currently loaded, if the
                printer supports input trays that can not sense the
                media size.  Complete list of supported media sizes
                along with their dimensions are listed in the ''Media
                Size Table'' near the end of this document.
                Additional information:
                Returns the media size that is currently configured 
                			in tray #1. This object can be set to indicate
                			the media size currently loaded, if the printer
                			supports input trays that cannot sense the media 
                			size. Complete list of supported media sizes along
                			with their dimensions are listed in the 'Media
                			Size Table' near the end of this document.  
                			This tray is built in and therefore, always installed."
::= { intray1 1 }
               
               
tray1-phd OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Provides the number of the Paper Handling Device that
                contains this input tray."
::= { intray1 12 }
               
               
tray2-media-size-loaded OBJECT-TYPE
    SYNTAX  INTEGER {
		   eUSLetter(2),
		   eUSLegal(3),
		   eISOandJISA4(26),
		   eJISB4(46)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the media size that is currently configured in
                tray #2.  Complete list of supported media sizes along
                with their dimensions are listed in the ''Media Size
                Table'' near the end of this document.
                Additional information:
                If the tray drawer is open, a get on this object will
                			cause a status of <genErr>
                			to be returned. If the tray is empty, the size that
                			the tray is configured for will be returned."
::= { intray2 1 }
               
               
tray2-phd OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Provides the number of the Paper Handling Device that
                contains this input tray."
::= { intray2 12 }
               
               
tray3-media-size-loaded OBJECT-TYPE
    SYNTAX  INTEGER {
		   eUSLetter(2),
		   eUSLegal(3),
		   eLedger(11),
		   eISOandJISA3(27),
		   eISOandJISA4(26),
		   eJISB4(46)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the media size that is currently configured in
                tray #3.  Complete list of supported media sizes along
                with their dimensions are listed in the ''Media Size
                Table'' near the end of this document.
                Additional information:
                 The Media Size Table does not exist in this document."
::= { intray3 1 }
               
               
tray3-phd OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Provides the number of the Paper Handling Device that
                contains this input tray."
::= { intray3 12 }
               
               
tray4-media-size-loaded OBJECT-TYPE
    SYNTAX  INTEGER {
		   eUSLetter(2),
		   eUSLegal(3),
		   eLedger(11),
		   eISOandJISA3(27),
		   eISOandJISA4(26),
		   eJISB4(46)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns the media size that is currently configured in
                tray #4.  Complete list of supported media sizes along
                with their dimensions are listed in the ''Media Size
                Table'' near the end of this document.
                Additional information:
                The Media Size Table does not exist in this document. 
                		Attempting to access this object when the tray is not installed
                		will result in an ErrorUnknownObjectIdentifier response from
                		the printer."
::= { intray4 1 }
               
               
tray4-phd OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Provides the number of the Paper Handling Device that
                contains this input tray."
::= { intray4 12 }
               
               
tray5-phd OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Provides the number of the Paper Handling Device that
                contains this input tray."
::= { intray5 12 }
               
               
overflow-bin OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns or sets the bin that will be used for additional
                sheets of media when the current bin is full and
                printing is allowed to continue.
                Additional information:
                If this object is set to zero, overflowing to another 
                			bin is not allowed."
::= { settings-outbin 4 }
               
               
outbin1-override-mode OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Returns or sets the device behavior when this output bin
                condition causes printing to stop.  
                  cCancelJob - The device cancels the job.  
                  cOutbinFullOverride - The device sends subsequent
                media to the overflow bin.  
                  cOutbinAttentionOverride - The device ignores the
                attention condition and continues printing.  
                  cBinderAttentionOverride - The device ignores the
                binder attention condition and continues printing.
                Additional information:
                If cCancelJob is set, the current print job 
                			will be cancelled regardless of other item settings.
                			If cOutbinFullOverride is set and this bin is the
                			designated overflow bin (OVERFLOW-BIN = 1), then
                			the bit is ignored. This object describes the action 
                			that is performed when the 
                			JOB-OUTPUT-AUTO-CONTINUE-TIMEOUT expires. If no bits
                			are set, no override action is taken (the printer will 
                			continue to wait). The action performed by the 
                			CONTINUE object being set to eInitiateAction or the GO
                			key being pressed on the control panel may cause 
                			different actions. See the 
                			CONTINUE object description for information on the 
                			actions that occur for those conditions."
::= { outbin1 9 }
               
               
outbin2-override-mode OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Returns or sets the device behavior when this output bin
                condition causes printing to stop.  
                  cCancelJob - The device cancels the job.  
                  cOutbinFullOverride - The device sends subsequent
                media to the overflow bin.  
                  cOutbinAttentionOverride - The device ignores the
                attention condition and continues printing.  
                  cBinderAttentionOverride - The device ignores the
                binder attention condition and continues printing.
                Additional information:
                See OUTBIN1-OVERRIDE-MODE."
::= { outbin2 9 }
               
               
outbin3-override-mode OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Returns or sets the device behavior when this output bin
                condition causes printing to stop.  
                  cCancelJob - The device cancels the job.  
                  cOutbinFullOverride - The device sends subsequent
                media to the overflow bin.  
                  cOutbinAttentionOverride - The device ignores the
                attention condition and continues printing.  
                  cBinderAttentionOverride - The device ignores the
                binder attention condition and continues printing.
                Additional information:
                See OUTBIN1-OVERRIDE-MODE."
::= { outbin3 9 }
               
               
outbin3-phd OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Provides the number of the Paper Handling Device that
                contains this output bin."
::= { outbin3 11 }
               
               
outbin4-override-mode OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Returns or sets the device behavior when this output bin
                condition causes printing to stop.  
                  cCancelJob - The device cancels the job.  
                  cOutbinFullOverride - The device sends subsequent
                media to the overflow bin.  
                  cOutbinAttentionOverride - The device ignores the
                attention condition and continues printing.  
                  cBinderAttentionOverride - The device ignores the
                binder attention condition and continues printing.
                Additional information:
                See OUTBIN1-OVERRIDE-MODE."
::= { outbin4 9 }
               
               
outbin4-phd OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Provides the number of the Paper Handling Device that
                contains this output bin."
::= { outbin4 11 }
               
               
outbin5-override-mode OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Returns or sets the device behavior when this output bin
                condition causes printing to stop.  
                  cCancelJob - The device cancels the job.  
                  cOutbinFullOverride - The device sends subsequent
                media to the overflow bin.  
                  cOutbinAttentionOverride - The device ignores the
                attention condition and continues printing.  
                  cBinderAttentionOverride - The device ignores the
                binder attention condition and continues printing.
                Additional information:
                See OUTBIN1-OVERRIDE-MODE."
::= { outbin5 9 }
               
               
outbin5-phd OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Provides the number of the Paper Handling Device that
                contains this output bin."
::= { outbin5 11 }
               
               
outbin6-override-mode OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Returns or sets the device behavior when this output bin
                condition causes printing to stop.  
                  cCancelJob - The device cancels the job.  
                  cOutbinFullOverride - The device sends subsequent
                media to the overflow bin.  
                  cOutbinAttentionOverride - The device ignores the
                attention condition and continues printing.  
                  cBinderAttentionOverride - The device ignores the
                binder attention condition and continues printing.
                Additional information:
                See OUTBIN1-OVERRIDE-MODE."
::= { outbin6 9 }
               
               
outbin6-phd OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Provides the number of the Paper Handling Device that
                contains this output bin."
::= { outbin6 11 }
               
               
outbin7-override-mode OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Returns or sets the device behavior when this output bin
                condition causes printing to stop.  
                  cCancelJob - The device cancels the job.  
                  cOutbinFullOverride - The device sends subsequent
                media to the overflow bin.  
                  cOutbinAttentionOverride - The device ignores the
                attention condition and continues printing.  
                  cBinderAttentionOverride - The device ignores the
                binder attention condition and continues printing.
                Additional information:
                See OUTBIN1-OVERRIDE-MODE."
::= { outbin7 9 }
               
               
outbin7-phd OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Provides the number of the Paper Handling Device that
                contains this output bin."
::= { outbin7 11 }
               
               
outbin8-override-mode OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Returns or sets the device behavior when this output bin
                condition causes printing to stop.  
                  cCancelJob - The device cancels the job.  
                  cOutbinFullOverride - The device sends subsequent
                media to the overflow bin.  
                  cOutbinAttentionOverride - The device ignores the
                attention condition and continues printing.  
                  cBinderAttentionOverride - The device ignores the
                binder attention condition and continues printing.
                Additional information:
                See OUTBIN1-OVERRIDE-MODE."
::= { outbin8 9 }
               
               
outbin8-phd OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Provides the number of the Paper Handling Device that
                contains this output bin."
::= { outbin8 11 }
               
               
outbin9-override-mode OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Returns or sets the device behavior when this output bin
                condition causes printing to stop.  
                  cCancelJob - The device cancels the job.  
                  cOutbinFullOverride - The device sends subsequent
                media to the overflow bin.  
                  cOutbinAttentionOverride - The device ignores the
                attention condition and continues printing.  
                  cBinderAttentionOverride - The device ignores the
                binder attention condition and continues printing.
                Additional information:
                See OUTBIN1-OVERRIDE-MODE."
::= { outbin9 9 }
               
               
outbin9-phd OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Provides the number of the Paper Handling Device that
                contains this output bin."
::= { outbin9 11 }
               
               
outbin10-override-mode OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Returns or sets the device behavior when this output bin
                condition causes printing to stop.  
                  cCancelJob - The device cancels the job.  
                  cOutbinFullOverride - The device sends subsequent
                media to the overflow bin.  
                  cOutbinAttentionOverride - The device ignores the
                attention condition and continues printing.  
                  cBinderAttentionOverride - The device ignores the
                binder attention condition and continues printing.
                Additional information:
                See OUTBIN1-OVERRIDE-MODE."
::= { outbin10 9 }
               
               
outbin10-phd OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Provides the number of the Paper Handling Device that
                contains this output bin."
::= { outbin10 11 }
               
               
outbin11-override-mode OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Returns or sets the device behavior when this output bin
                condition causes printing to stop.  
                  cCancelJob - The device cancels the job.  
                  cOutbinFullOverride - The device sends subsequent
                media to the overflow bin.  
                  cOutbinAttentionOverride - The device ignores the
                attention condition and continues printing.  
                  cBinderAttentionOverride - The device ignores the
                binder attention condition and continues printing.
                Additional information:
                See OUTBIN1-OVERRIDE-MODE."
::= { outbin11 9 }
               
               
outbin11-phd OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Provides the number of the Paper Handling Device that
                contains this output bin."
::= { outbin11 11 }
               
               
low-marking-agent-processing OBJECT-TYPE
    SYNTAX  INTEGER {
		   eStop(1),
		   eCont(2)
		   }
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Returns or changes how the device processes a low
                marking agent event.  If eCont, then the device
                continues to print.  If eStop, then the device stops
                until a continue event occurs."
::= { settings-marking-agent 3 }
               
               
default-ret OBJECT-TYPE
    SYNTAX  INTEGER {
		   eOff(1)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns or changes the Resolution Enhancement Technology
                setting.  Devices that only support eOff and on should
                map all other values to on and always return the same
                non-eOff value to indicate on.  The list of supported
                values should be documented in the device POS.
                Additional information:
                Color LaserJet8550 doesn't have RET."
::= { imaging 5 }
               
               
default-print-quality OBJECT-TYPE
    SYNTAX  INTEGER(100..100)
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Returns or sets the default print quality.  A value of
                zero has the lowest print quality.  A value of 100 has
                the highest print quality.  Each POS should document
                what values in the 0 to 100 range are supported.
                Additional information:
                In Color LaserJet8550, the supported value is 100.  
                A value of 100 corresponds to ECONOMODE=OFF."
::= { imaging 7 }
               
               
phd2-device-specific-command OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  write-only
    STATUS  optional
    DESCRIPTION
                "This object is used to send device-specific data to the
                paper handling device.  The meaning of the device-
                specific command is dependent on the paper handling
                device and must be specified in the POS.  
                If the paper handling device does not accept the
                command, then an <badValue> will
                be returned.  If the device accepts the command, it may
                still be processing the command after the response has
                been returned.  Depending on the device, the application
                may need to query PHDx-DEVICE-MEMORY to see when the
                command has completed.
                Additional information:
                If at least one (1) external paper handling device is 
                		attached to the printer, then this object will exist.
                		Not applicable if the value of PHD2-TYPE is eEmpty.
                		Since it will usually take longer to send this command
                		to the device than PML allows for <set> operations, this
                		object will have a return value that does not necessarily
                		match the value currently received by the first device."
::= { ph2 2 }
               
               
phd2-device-memory OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(16))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "This object is used to read the current values stored in
                shared memory available from the paper handling device.
                Additional information:
                If at least one external paper handling devices are attached
                		to the printer, then this object will exist.
                		Not applicable if the value of PHD2-TYPE is eEmpty.
                		This object returns the current memory stored in the 
                		printer's NVRAM (non-volatile RAM) for the first paper
                		handling device. Currently, the printer allocates 16 bytes
                		for each device."
::= { ph2 4 }
               
               
phd3-device-specific-command OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  write-only
    STATUS  optional
    DESCRIPTION
                "This object is used to send device-specific data to the
                paper handling device.  The meaning of the device-
                specific command is dependent on the paper handling
                device and must be specified in the POS.  
                If the paper handling device does not accept the
                command, then an <badValue> will
                be returned.  If the device accepts the command, it may
                still be processing the command after the response has
                been returned.  Depending on the device, the application
                may need to query PHDx-DEVICE-MEMORY to see when the
                command has completed.
                Additional information:
                If at least two (2) external paper handling
                			devices are attached to the printer, then this object
                			will exist. Not applicable if the value of PHD3-TYPE 
                			is eEmpty.
                			Since it will usually take longer to send this 
                			command to the device than PML allows for <Set>
                			operations, this object will have a return value
                			that does not necessarily match the value currently
                			received by the second device."
::= { ph3 2 }
               
               
phd3-device-memory OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(16))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "This object is used to read the current values stored in
                shared memory available from the paper handling device.
                Additional information:
                If at least two external paper handling devices are attached
                		to the printer, then this object will exist.
                		Not applicable if the value of PHD3-TYPE is eEmpty.
                		This object returns the current memory stored in the 
                		printer's NVRAM (non-volatile RAM) for the second paper
                		handling device. Currently, the printer allocates 16 bytes
                		for each device."
::= { ph3 4 }
               
               
media-names-available OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "The value of this object controls which of the MEDIAx-
                NAME objects are supported.  If a bit is set to zero,
                then attempting to get or set the corresponding MEDIAx-
                NAME objects will return
                <noSuchName>.
                Additional information:
                Setting a bit to one will cause the corresponding
                		MEDIAn- objects to be available (attempting to access an 
                		unavailable object will return <noSuchName>).
                		MEDIA1- objects are always present in Color LaserJet8550, as this is the 
                		default media. If this object is set to a value that does not 
                		include cMediaName1Available, that bit will be set and a 
                		status of <noError> will be returned."
::= { settings-print-media 1 }
               
               
media1-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Media 1 name.
                Additional information:
                The symbol set for this string is Roman-8."
::= { media1 1 }
               
               
media1-short-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Length restricted version of the media name 1.  The
                length restriction is required to allow the media name
                to be displayed on the device's control panel.  The
                device POS must state the maximum number of characters
                allowed.  If the device also has a limitation on what
                characters in a character set can be used (e.g. only
                uppercase characters allowed), the POS should also state
                character restrictions.
                Additional information:
                The Maximum supported string length is 
                			9 characters. If the user entered string is too long,
                			the device will store the first 9 characters and will
                			return the <noError> status."
::= { media1 2 }
               
               
media1-page-count OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Number of sheets of media 1 that have been printed.  The
                device POS should state whether this value is lost
                across a power cycle or kept in NVRAM.
                Additional information:
                In Color LaserJet8550 the media page count saved in NVRAM 
                			after every 10 pages. The maximum value is 
                			4,294,967,295 which will never be reached in normal 
                			operation.  
                			The page count is incremented when a sheet of media is 
                			pulled from an input tray. A duplex printed sheet will 
                			cause this counter to be incremented by one."
::= { media1 3 }
               
               
media2-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Media 2 name.
                Additional information:
                See MEDIA1-NAME."
::= { media2 1 }
               
               
media2-short-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Length restricted version of the media name 2.  See
                MEDIA1-SHORT-NAME for details."
::= { media2 2 }
               
               
media2-page-count OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Number of sheets of media 2 that have been printed.  See
                MEDIA1-PAGE-COUNT for details.
                Additional information:
                See MEDIA1-PAGE-COUNT."
::= { media2 3 }
               
               
media3-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Media 3 name.
                Additional information:
                See MEDIA1-NAME."
::= { media3 1 }
               
               
media3-short-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Length restricted version of the media name 3.  See
                MEDIA1-SHORT-NAME for details."
::= { media3 2 }
               
               
media3-page-count OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Number of sheets of media 3 that have been printed.  See
                MEDIA1-PAGE-COUNT for details.
                Additional information:
                See MEDIA1-PAGE-COUNT."
::= { media3 3 }
               
               
media4-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Media 4 name.
                Additional information:
                See MEDIA1-NAME."
::= { media4 1 }
               
               
media4-short-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Length restricted version of the media name 4.  See
                MEDIA1-SHORT-NAME for details."
::= { media4 2 }
               
               
media4-page-count OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Number of sheets of media 4 that have been printed.  See
                MEDIA1-PAGE-COUNT for details.
                Additional information:
                See MEDIA1-PAGE-COUNT."
::= { media4 3 }
               
               
media5-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Media 5 name.
                Additional information:
                See MEDIA1-NAME."
::= { media5 1 }
               
               
media5-short-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Length restricted version of the media name 5.  See
                MEDIA1-SHORT-NAME for details."
::= { media5 2 }
               
               
media5-page-count OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Number of sheets of media 5 that have been printed.  See
                MEDIA1-PAGE-COUNT for details.
                Additional information:
                See MEDIA1-PAGE-COUNT."
::= { media5 3 }
               
               
media6-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Media 6 name.
                Additional information:
                See MEDIA1-NAME."
::= { media6 1 }
               
               
media6-short-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Length restricted version of the media name 6.  See
                MEDIA1-SHORT-NAME for details."
::= { media6 2 }
               
               
media6-page-count OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Number of sheets of media 6 that have been printed.  See
                MEDIA1-PAGE-COUNT for details.
                Additional information:
                See MEDIA1-PAGE-COUNT."
::= { media6 3 }
               
               
media7-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Media 7 name.
                Additional information:
                See MEDIA1-NAME."
::= { media7 1 }
               
               
media7-short-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Length restricted version of the media name 7.  See
                MEDIA1-SHORT-NAME for details."
::= { media7 2 }
               
               
media7-page-count OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Number of sheets of media 7 that have been printed.  See
                MEDIA1-PAGE-COUNT for details.
                Additional information:
                See MEDIA1-PAGE-COUNT."
::= { media7 3 }
               
               
media8-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Media 8 name.
                Additional information:
                See MEDIA1-NAME."
::= { media8 1 }
               
               
media8-short-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Length restricted version of the media name 8.  See
                MEDIA1-SHORT-NAME for details."
::= { media8 2 }
               
               
media8-page-count OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Number of sheets of media 8 that have been printed.  See
                MEDIA1-PAGE-COUNT for details.
                Additional information:
                See MEDIA1-PAGE-COUNT."
::= { media8 3 }
               
               
media9-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Media 9 name.
                Additional information:
                See MEDIA1-NAME."
::= { media9 1 }
               
               
media9-short-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Length restricted version of the media name 9.  See
                MEDIA1-SHORT-NAME for details."
::= { media9 2 }
               
               
media9-page-count OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Number of sheets of media 9 that have been printed.  See
                MEDIA1-PAGE-COUNT for details.
                Additional information:
                See MEDIA1-PAGE-COUNT."
::= { media9 3 }
               
               
media10-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Media 10 name.
                Additional information:
                See MEDIA1-NAME."
::= { media10 1 }
               
               
media10-short-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Length restricted version of the media name 10.  See
                MEDIA1-SHORT-NAME for details."
::= { media10 2 }
               
               
media10-page-count OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Number of sheets of media 10 that have been printed.
                See MEDIA1-PAGE-COUNT for details.
                Additional information:
                See MEDIA1-PAGE-COUNT."
::= { media10 3 }
               
               
media11-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Media 11 name.
                Additional information:
                See MEDIA1-NAME."
::= { media11 1 }
               
               
media11-short-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Length restricted version of the media name 11.  See
                MEDIA1-SHORT-NAME for details."
::= { media11 2 }
               
               
media11-page-count OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Number of sheets of media 11 that have been printed.
                See MEDIA1-PAGE-COUNT for details.
                Additional information:
                See MEDIA1-PAGE-COUNT."
::= { media11 3 }
               
               
media12-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Media 12 name.
                Additional information:
                See MEDIA1-NAME."
::= { media12 1 }
               
               
media12-short-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Length restricted version of the media name 12.  See
                MEDIA1-SHORT-NAME for details."
::= { media12 2 }
               
               
media12-page-count OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Number of sheets of media 12 that have been printed.
                See MEDIA1-PAGE-COUNT for details.
                Additional information:
                See MEDIA1-PAGE-COUNT."
::= { media12 3 }
               
               
media13-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Media 13 name.
                Additional information:
                See MEDIA1-NAME."
::= { media13 1 }
               
               
media13-short-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Length restricted version of the media name 13.  See
                MEDIA1-SHORT-NAME for details.
                Additional information:
                See MEDIA1-SHORT-NAME."
::= { media13 2 }
               
               
media13-page-count OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Number of sheets of media 13 that have been printed.
                See MEDIA1-PAGE-COUNT for details.
                Additional information:
                See MEDIA1-PAGE-COUNT."
::= { media13 3 }
               
               
media14-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Media 14 name.
                Additional information:
                See MEDIA1-NAME."
::= { media14 1 }
               
               
media14-short-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Length restricted version of the media name 14.  See
                MEDIA1-SHORT-NAME for details.
                Additional information:
                See MEDIA1-SHORT-NAME."
::= { media14 2 }
               
               
media14-page-count OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Number of sheets of media 14 that have been printed.
                See MEDIA1-PAGE-COUNT for details.
                Additional information:
                See MEDIA1-PAGE-COUNT."
::= { media14 3 }
               
               
media15-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Media 15 name.
                Additional information:
                See MEDIA1-NAME."
::= { media15 1 }
               
               
media15-short-name OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Length restricted version of the media name 15.  See
                MEDIA1-SHORT-NAME for details.
                Additional information:
                See MEDIA1-SHORT-NAME."
::= { media15 2 }
               
               
media15-page-count OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Number of sheets of media 15 that have been printed.
                See MEDIA1-PAGE-COUNT for details.
                Additional information:
                See MEDIA1-PAGE-COUNT."
::= { media15 3 }
               
               
channel-bytes-sent OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The low order 31 bits of the number of bytes sent from
                the printer to the host on this logical channel."
::= { channel-entry 2 }
               
               
channel-bytes-received OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The low order 31 bits of the number of bytes received by
                the printer from the host on this logical channel."
::= { channel-entry 3 }
               
               
channel-io-errors OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The low order 31 bits of the number of I/O errors which
                have occured on this logical channel."
::= { channel-entry 4 }
               
               
channel-jobs-received OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The low order 31 bits of the number of print jobs which
                have been received on this logical channel."
::= { channel-entry 5 }
               
               
channel-mio OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The number of the MIO card associated with this logical
                channel.  If this logical channel is not associated with
                an MIO card a zero is returned.  The value returned for
                each logical channel is the  MIO card's physical slot
                number.    The list of supported values should be
                documented in the device POS.
                Additional information:
                The value returned will be zero for channel one.  
                If an MIOA card is installed, channels 3..18 will 
                return a value of one or two and, 
                if an MIOB card is installed, 19-34 will return a 
                value of one or two, but not the same as channels 
                3..18. When two MIO cards are installed, the value 
                returned by any channel 3..34 may change after the 
                printer is power cycled."
::= { channel-entry 6 }
               
               
mass-storage-resource-change-counter OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "A counter which changes when a mass storage based
                resource has been added or deleted.
                Additional information:
                The value of this counter changes 
                each time the MASS-STORAGE-RESOURCE-CHANGED object
                is set to eTrue.  The value also changes when the 
                mass storage device is initialized.  However, the value does not
                change when a mass storage device is removed and a different
                mass storage device is installed.  Performing a cold reset sets 
                this object back to the factory default value. 
                Returns <noSuchName>
                status if attempting to access this object and there
                is no storage device is installed."
::= { mass-storage-resources 1 }
               
               
mass-storage-resource-changed OBJECT-TYPE
    SYNTAX  INTEGER {
		   eTrue(2)
		   }
    ACCESS  write-only
    STATUS  optional
    DESCRIPTION
                "Setting to eTrue causes MASS-STORAGE-RESOURCE-CHANGE-
                COUNTER to be incremented.
                Additional information:
                Returns <noSuchName>
                status if attempting to access this object and there
                is no storage device is installed."
::= { mass-storage-resources 2 }
               
               
hrdiskstorageaccess OBJECT-TYPE
    SYNTAX  INTEGER {
		   eHreadWrite(1),
		   eHreadOnly(2)
		   }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "An indication if this long-term storage device is
              readable and writable or only readable.  This
              should reflect the media type, any write-protect
              mechanism, and any device configuration that
              affects the entire device.
              Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                This object can be set to write protect
                the mass storage device, even though the host resources MIB
                documents the object as read-only.  
                Returns <noSuchName> status if attempting
                to perform a Get on this OID with no mass storage device
                installed."
::= { hrDiskStorageEntry 1 }
               
               
hrdiskstoragemedia OBJECT-TYPE
    SYNTAX  INTEGER {
		   eHother(1),
		   eHhardDisk(3)
		   }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "An indication of the type of media used in this
              long-term storage device.
              Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                Constant.  Returns <noSuchName> 
                	   	status if attempting to perform a Get on this OID with no 
                		mass storage device installed."
::= { hrDiskStorageEntry 2 }
               
               
hrdiskstorageremoveble OBJECT-TYPE
    SYNTAX  INTEGER {
		   eHfalse(2)
		   }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Denotes whether or not the disk media may be
               removed from the drive.
               Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                Constant.  Returns
                <noSuchName> status if attempting
                to perform a Get on this OID with no mass storage device
                installed."
::= { hrDiskStorageEntry 3 }
               
               
hrdiskstoragecapacity OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The total size for this long-term storage device.
              Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                The capacity is in Kbytes.  Returns
                <noSuchName> status if attempting
                to perform a Get on this OID with no mass storage device
                installed."
::= { hrDiskStorageEntry 4 }
               
               
hrpartitionindex OBJECT-TYPE
    SYNTAX  INTEGER(1..2147483647)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A unique value for each partition on this long-
              term storage device.  The value for each long-term
              storage device must remain constant at least from
              one re-initialization of the agent to the next re-
              initialization.
              Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                Constant.  The first and second index 
                indicates the hrDeviceIndex for this mass storage device.
                The value of this object is the same as
                the second index.  The printer only supports one
                partition per mass storage device.  Returns
                <noSuchName> status if attempting
                to perform a Get on this OID with no mass storage device
                installed."
::= { hrPartitionEntry 1 }
               
               
hrpartitionlabel OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..128))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A textual description of this partition.
              Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                The MS-DOS volume label.  The volume
                label is not writable.  Returns <noSuchName> 
                	   status if attempting to perform a Get on this OID with no mass 
                	   storage device installed.
                This object is not settable and returns the empty 
                string if the mass storage device has not been initialized."
::= { hrPartitionEntry 2 }
               
               
hrpartitionid OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A descriptor which uniquely represents this
              partition to the responsible operating system.  On
              some systems, this might take on a binary
              representation.
              Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                Constant.  The value returned is the
                ASCII string version of the hrDeviceIndex for 
                this mass storage device.  Returns <noSuchName> 
                	   status if attempting to perform a Get on this OID with no mass 
                	   storage device installed."
::= { hrPartitionEntry 3 }
               
               
hrpartitionsize OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The size of this partition.
               Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                The capacity is in Kbytes.  Returns the
                same value as hrDiskStorageCapacity.  Returns
                <noSuchName> status if attempting
                to perform a Get on this OID with no mass storage device
                installed."
::= { hrPartitionEntry 4 }
               
               
hrpartitionfsindex OBJECT-TYPE
    SYNTAX  INTEGER(0..2147483647)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The index of the file system mounted on this
               partition.  If no file system is mounted on this
               partition, then this value shall be zero.  Note
               that multiple partitions may point to one file
               system, denoting that that file system resides on
               those partitions.  Multiple file systems may not
               reside on one partition.
               Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                Indicates if the mass storage device has been
                initialized.  Returns zero if the mass storage device is not
                initialized, otherwise the value matches the
                hrDeviceIndex value for this mass storage device.
                The value indicates the hrFileSystemTable index for the 
                	   file system stored on this partition.  Returns
                <noSuchName> status if attempting
                to perform a Get on this OID with no mass storage device
                installed."
::= { hrPartitionEntry 5 }
               
               
hrfsindex OBJECT-TYPE
    SYNTAX  INTEGER(1..2147483647)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A unique value for each file system local to this
               host.  The value for each file system must remain
               constant at least from one re-initialization of
               the agent to the next re-initialization.
               Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                Constant.  The index is assigned by the
                person controlling the printer object definition.
                Returns <noSuchName> status if
                attempting to perform a Get on this OID with no mass storage device
                installed or if the file system has not been initialized."
::= { hrFSEntry 1 }
               
               
hrfsmountpoint OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The path name of the root of this file system.
               Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                Constant.  Returns <noSuchName> 
                	   status if attempting to perform a Get on this OID with no mass 
                	   storage device installed or if the file system has not been 
                	   initialized."
::= { hrFSEntry 2 }
               
               
hrfsremotemountpoint OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A description of the name and/or address of the
               server that this file system is mounted from.
               This may also include parameters such as the mount
               point on the remote file system.  If this is not a
               remote file system, this string should have a
               length of zero.
               Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                Constant.  This printer does not support
                remote file system mounting.  Returns
                <noSuchName> status if attempting
                to perform a Get on this OID with no mass storage device installed
                or if the file system has not been initialized."
::= { hrFSEntry 3 }
               
               
hrfstype OBJECT-TYPE
    SYNTAX  OBJECT IDENTIFIER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The value of this object identifies the type of
              this file system.
              Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                Constant.  Returns <noSuchName> 
                	   status if attempting to perform a Get on this OID with no mass 
                	   storage device installed or if the file system has not been 
                	   initialized."
::= { hrFSEntry 4 }
               
               
hrfsaccess OBJECT-TYPE
    SYNTAX  INTEGER {
		   eHreadWrite(1),
		   eHreadOnly(2)
		   }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "An indication if this file system is logically
              configured by the operating system to be readable
              and writable or only readable.  This does not
              represent any local access-control policy, except
              one that is applied to the file system as a whole.
              Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                Returns the same value as hrDiskStorageAccess.  
                	   Returns <noSuchName> status if attempting
                to perform a Get on this OID with no mass storage device installed
                or if the file system has not been initialized."
::= { hrFSEntry 5 }
               
               
hrfsbootable OBJECT-TYPE
    SYNTAX  INTEGER {
		   eHfalse(2)
		   }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A flag indicating whether this file system is
              bootable.
              Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                Constant.  Returns <noSuchName> 
                	    status if attempting to perform a Get on this OID with no mass 
                	    storage device installed or if the file system has not been 
                	    initialized."
::= { hrFSEntry 6 }
               
               
hrfsstorageindex OBJECT-TYPE
    SYNTAX  INTEGER(0..2147483647)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The index of the hrStorageEntry that represents
               information about this file system.  If there is
               no such information available, then this value
               shall be zero.  The relevant storage entry will be
               useful in tracking the percent usage of this file
               system and diagnosing errors that may occur when
               it runs out of space.
               Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                Constant.  The value indicates the
                hrStorageTable index for this mass storage device.  Returns
                <noSuchName> status if attempting
                to perform a Get on this OID with no mass storage device installed
                or if the file system has not been initialized."
::= { hrFSEntry 7 }
               
               
hrfslastfullbackupdate OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The last date at which this complete file system
              was copied to another storage device for backup.
              This information is useful for ensuring that
              backups are being performed regularly.
              If this information is not known, then this
              variable shall have the value corresponding to
              January 1, year 0000, 00:00:00.0, which is encoded
              as (hex)'00 00 01 01 00 00 00 00'.
              Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                Constant. The default value is the value defined
                to represent an unknown time of January 1, year 0000,
                00:00:00.0.  Returns <noSuchName>
                status if attempting to perform a Get on this OID with no mass 
                	   storage device installed or if the file system has not
                been initialized."
::= { hrFSEntry 8 }
               
               
hrfslastpartialbackupdate OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The last date at which a portion of this file
              system was copied to another storage device for
              backup.  This information is useful for ensuring
              that backups are being performed regularly.
              If this information is not known, then this
              variable shall have the value corresponding to
              January 1, year 0000, 00:00:00.0, which is encoded
              as (hex)'00 00 01 01 00 00 00 00'.
              Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                Constant. The default value is the value defined
                to represent an unknown time of January 1, year 0000,
                00:00:00.0.  Returns <noSuchName> status if 
                	   attempting to perform a Get on this OID with no mass storage 
                	   device installed or if the file system has not been initialized."
::= { hrFSEntry 9 }
               
               
hrmemorysize OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The amount of physical main memory contained by
              the host.
              Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                The unit of measure for this object is 1024 bytes.  
                The default value assumes the base printer with no 
                additional memory."
::= { hrStorage 2 }
               
               
hrstorageindex OBJECT-TYPE
    SYNTAX  INTEGER(1..2147483647)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A unique value for each logical storage area
              contained by the host.
              Refer to RFC 1514, Host Resources MIB, for more details."
::= { hrStorageEntry 1 }
               
               
hrstoragetype OBJECT-TYPE
    SYNTAX  OBJECT IDENTIFIER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The type of storage represented by this entry.
              Refer to RFC 1514, Host Resources MIB, for more details."
::= { hrStorageEntry 2 }
               
               
hrstoragedescr OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A description of the type and instance of the
              storage described by this entry.
              Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                This object is not localized."
::= { hrStorageEntry 3 }
               
               
hrstorageallocationunits OBJECT-TYPE
    SYNTAX  INTEGER(1..2147483647)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The size, in bytes, of the data objects allocated
               from this pool.  If this entry is monitoring
               sectors, blocks, buffers, or packets, for example,
               this number will commonly be greater than one.
               Otherwise this number will typically be one.
               Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                Unit is one byte.   
                		The size, in bytes, of the data objects allocated from 
                		this pool. If this entry is monitoring sectors, blocks, 
                		buffers, or packets, for example, this number will commonly
                		be greater than one. Otherwise this number will typically
                		be one."
::= { hrStorageEntry 4 }
               
               
hrstoragesize OBJECT-TYPE
    SYNTAX  INTEGER(0..2147483647)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The size of the storage represented by this entry,
              in units of hrStorageAllocationUnits.
              Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                Total formatter RAM. Color LaserJet8550 has 0 byte of memory
                			soldered on the formatter."
::= { hrStorageEntry 5 }
               
               
hrstorageused OBJECT-TYPE
    SYNTAX  INTEGER(0..2147483647)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The amount of the storage represented by this
              entry that is allocated, in units of
              hrStorageAllocationUnits.
              Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                This object returns the amount of memory in use
                		by the printer at the current time. This object should 
                		not be used when creating a print job for the device 
                		because the amount of memory in use will likely be different 
                		when the printer processes the print job."
::= { hrStorageEntry 6 }
               
               
hrstorageallocationfailures OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The number of requests for storage represented by
              this entry that could not be honored due to not
              enough storage.  It should be noted that as this
              object has a SYNTAX of Counter, that it does not
              have a defined initial value.  However, it is
              recommended that this object be initialized to
              zero.
              Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                This object is set to zero at power on and when any 
                reset is done via prtGeneralReset.  
                This object is incremented whenever the printer is 
                			short on memory or out of memory/job cleared."
::= { hrStorageEntry 7 }
               
               
hrdeviceindex OBJECT-TYPE
    SYNTAX  INTEGER(1..2147483647)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A unique value for each device contained by the
              host.  The value for each device must remain
              constant at least from one re-initialization of the
              agent to the next re-initialization.
              Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                The entry in the Device Table which
                describes the printer. "
::= { hrDeviceEntry 1 }
               
               
hrdevicetype OBJECT-TYPE
    SYNTAX  OBJECT IDENTIFIER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "An indication of the type of device.
              If this value is `hrDeviceProcessor { hrDeviceTypes
              3 }' then an entry exists in the hrProcessorTable
              which corresponds to this device.
              If this value is `hrDeviceNetwork { hrDeviceTypes 4
              }', then an entry exists in the hrNetworkTable
              which corresponds to this device.
              If this value is `hrDevicePrinter { hrDeviceTypes 5
              }', then an entry exists in the hrPrinterTable
              which corresponds to this device.
              If this value is `hrDeviceDiskStorage {
              hrDeviceTypes 6 }', then an entry exists in the
              hrDiskStorageTable which corresponds to this
              device.
              Refer to RFC 1514, Host Resources MIB, for more details."
::= { hrDeviceEntry 2 }
               
               
hrdevicedescr OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..64))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A textual description of this device, including
              the device's manufacturer and revision, and
              optionally, its serial number.
              Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                This object is not localized."
::= { hrDeviceEntry 3 }
               
               
hrdeviceid OBJECT-TYPE
    SYNTAX  OBJECT IDENTIFIER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The product ID for this device.
              Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                The complete OID reported by this object is:  
                		.1.3.6.1.4.1.11.2.3.9.1.2.10"
::= { hrDeviceEntry 4 }
               
               
hrdevicestatus OBJECT-TYPE
    SYNTAX  INTEGER {
		   eHrunning(2),
		   eHwarning(3),
		   eHdown(5)
		   }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The current operational state of the device
              described by this row of the table.  A value
              unknown(1) indicates that the current state of the
              device is unknown.  running(2) indicates that the
              device is up and running and that no unusual error
              conditions are known.  The warning(3) state
              indicates that agent has been informed of an
              unusual error condition by the operational software
              (e.g., a disk device driver) but that the device is
              still 'operational'.  An example would be high
              number of soft errors on a disk.  A value of
              testing(4), indicates that the device is not
              available for use because it is in the testing
              state.  The state of down(5) is used only when the
              agent has been informed that the device is not
              available for any use.
              Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                The printer's condition is mapped as follows:  
                eHrunning -- Printer ready to print or is printing.
                		May be in power save mode.  
                eHwarning -- A condition exists that needs attention but it is
                not currently preventing printing. A non-critical alert is
                		active.  
                eHdown -- Printer is not printing due to an error condition. 
                		A critical alert is active, human interaction is needed to 
                		bring the printer to a ready state."
::= { hrDeviceEntry 5 }
               
               
hrdeviceerrors OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The number of errors detected on this device.  It
               should be noted that as this object has a SYNTAX
               of Counter, that it does not have a defined
               initial value.  However, it is recommended that
               this object be initialized to zero.
               Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                This is the number of critical alerts that have been 
                entered into the alert table since the device was powered on.
                The maximum value for this object is 2^32-1."
::= { hrDeviceEntry 6 }
               
               
hrprinterstatus OBJECT-TYPE
    SYNTAX  INTEGER {
		   eHother(1),
		   eHidle(3),
		   eHprinting(4),
		   eHwarmup(5)
		   }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The current status of this printer device.  When
               in the idle(1), printing(2), or warmup(3) state,
               the corresponding hrDeviceStatus should be
               running(2) or warning(3).  When in the unknown
               state, the corresponding hrDeviceStatus should be
               unknown(1).
               Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                The printer's condition is mapped as follows:  
                	      eHother -- The printer is offline or a critical alert is 
                		active.  
                eHidle -- The printer is not doing any of the items listed below
                for eHprinting status.  
                eHprinting -- The printer is processing PJL or PDL data, 
                or processeing a control panel request, or printing images.  
                eHwarmup -- If hrDeviceStatus is eHdown, then the printer is
                currently offline but is resolving the condition that caused 
                		it be offline. It will be online when it is ready to print. 
                		If hrDeviceStatus is eHrunning, then the printer was in power 
                		save mode and is now becoming ready to print."
::= { hrPrinterEntry 1 }
               
               
hrprinterdetectederrorstate OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This object represents any error conditions
               detected by the printer.  The error conditions are
               encoded as bits in an octet string, with the
               following definitions:
                    Condition         Bit #    hrDeviceStatus
                    lowPaper          0        warning(3)
                    noPaper           1        down(5)
                    lowToner          2        warning(3)
                    noToner           3        down(5)
                    doorOpen          4        down(5)
                    jammed            5        down(5)
                    offline           6        down(5)
                    serviceRequested  7        warning(3)
               If multiple conditions are currently detected and
               the hrDeviceStatus would not otherwise be
               unknown(1) or testing(4), the hrDeviceStatus shall
               correspond to the worst state of those indicated,
               where down(5) is worse than warning(3) which is
               worse than running(2).
               Bits are numbered starting with the most
               significant bit of the first byte being bit 0, the
               least significant bit of the first byte being bit
               7, the most significant bit of the second byte
               being bit 8, and so on.  A one bit encodes that
               the condition was detected, while a zero bit
               encodes that the condition was not detected.
               This object is useful for alerting an operator to
               specific warning or error conditions that may
               occur, especially those requiring human
               intervention.
               Refer to RFC 1514, Host Resources MIB, for more details.
                Additional information:
                Color LaserJet8550 reports error conditions as follows:  
                lowPaper -- A tray is empty, but the media to be loaded is not
                currently needed.
                hrDeviceStatus = eHwarning;
                hrPrinterStatus = eHidle or eHprinting;
                a non-critical alert is active.  
                noPaper -- A tray is empty and must be filled for printing to
                continue.
                hrDeviceStatus = eHdown;
                hrPrinterStatus = eHother;
                a non-critical alert is active.  
                lowToner -- Toner is almost gone. The quality of printed pages
                		will begin to deteriorate until the toner is completely gone. 
                hrDeviceStatus = eHwarning;
                hrPrinterStatus = eHidle or eHprinting;
                a non-critical alert is active.  
                noToner -- Toner Low 2 or no cartridge installed.   
                CoverOpen -- A Cover is open.
                hrDeviceStatus = eHdown;
                hrPrinterStatus = eHother;
                a non-critical alert is active.  
                jammed -- A jam condition is preventing printing.
                hrDeviceStatus = eHdown;
                hrPrinterStatus = eHother;
                a critical alert is active.  
                offline -- Printer is offline.
                hrDeviceStatus = eHdown;
                hrPrinterStatus = eHother;
                a critical alert is active.  
                serviceRequested -- Any status or error condition not listed
                above. If the condition prevents printing, the 'offline'
                bit is also set and the hrDeviceStatus and hrPrinterStatus
                		 listed for offline above are returned. 
                hrDeviceStatus = eHwarning;
                hrPrinterStatus = eHidle or eHprinting;
                a non-critical alert is active."
::= { hrPrinterEntry 2 }
               
               
channelnumberofchannels OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  write-only
    STATUS  optional
    DESCRIPTION
                "An indication of how many print data channels the I/O
                card supports.
                Additional information:
                This object is used by the MIO card to tell the peripheral
                firmware how many logical channels will be used by the card.
                This object can only be set once per physical channel.  If
                an attempt is made to set it a subsequent time it is ignored
                and an return code of <genErr>
                is returned.  
                If new firmware is dynamically downloaded to the IO card
                card, and if that firmware uses more logical channels, it is
                necessary to reset the printer."
::= { channel 1 }
               
               
channelprinteralert OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Identifies the values of prtAlertIndex,
                prtAlertSeverityLevel, prtAlertGroup,
                prtAlertGroupIndex, prtAlertLocation, and prtAlertCode
                for the latest critical evnet in the prtAlertTable.  The
                binary string is defined as following:  
                ------------------------------------------------------  
                 Field | Filed  | Description  
                Offset | Length |  
                ------------------------------------------------------  
                   0   |    4   | the value of prtAlertIndex  
                   4   |    4   | the value of prtAlertSeverityLevel  
                   8   |    4   | the value of prtAlertGroup  
                  12   |    4   | the value of prtAlertGroupIndex  
                  16   |    4   | the value of prtAlertLocation  
                  20   |    4   | the value of prtAlertCode  
                ------------------------------------------------------  
                Each field is in Big Endian style.
                Additional information:
                This object is used to pass alert information from the
                peripheral to the MIO card.  The standard printer MIB
                contains the following description:  
                printerAlert TRAP-TYPE  
                ENTERPRISE printerV1Alert  
                VARIABLES { prtAlertIndex, prtAlertSeverityLevel, prtAlertGroup,
                prtAlertGroupIndex, prtAlertLocation, prtAlertCode }  
                DESCRIPTION  
                'This trap is sent whenever a critical event is added to the
                prtAlertTable.'  
                In order to provide this information in the trap packet, the 
                MIO card enables traps on channelPrinterAlert.  When a critical
                alert is generated the peripheral fills the appropriate value
                into this object and sends it to the card.
                This object is a structure which contains 24 bytes of data.
                The structure is:  
                struct structAlertInfo {  
                sint32 prtAlertIndex;  
                sint32 prtAlertSeverityLevel;  
                sint32 prtAlertGroup;  
                sint32 prtAlertGroupIndex;  
                sint32 prtAlertLocation;  
                sint32 prtAlertCode;  
                } thisAlertData;"
::= { channel 2 }
               
               
channeltype OBJECT-TYPE
    SYNTAX  INTEGER {
		   eChOther(1),
		   eChAppleTalkPAP(7),
		   eChLPDServer(8),
		   eChNetwareRPrinter(9),
		   eChNetwarePServer(10),
		   eChPort9100(11),
		   eChDLCLLCPort(15),
		   eChBidirPortTCP(38)
		   }
    ACCESS  write-only
    STATUS  optional
    DESCRIPTION
                "Identifies the type of MIO print data channel.
                Additional information:
                This object is for use by the I/O card only. After telling 
                		the peripheral how many logical channels will be used, 
                		the MIO card tells the printer the type of each of the 
                		channels. The type information is passed using the channelType 
                		object. Values are then saved by the peripheral and reported 
                		when users request the value of prtChannelType."
::= { channelEntry 2 }
               
               
channelprotocolversion OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  write-only
    STATUS  optional
    DESCRIPTION
                "The version of the protocol used on this MIO print data
                channel.
                Additional information:
                This object is for use by the I/O card only. After telling 
                		the peripheral how many logical channels will be used, 
                		the MIO card tells the printer the protocol version of each 
                		of the channels. The protocol version information is passed 
                		using the channelProtocolVersion object. Values are then saved 
                		by the peripheral and reported when users request the value of 
                		prtChannelProtocolVersion."
::= { channelEntry 3 }
               
               
channelstate OBJECT-TYPE
    SYNTAX  INTEGER {
		   eChOther(1),
		   eChPrintDataAccecped(3),
		   eChNoDataAccepted(4)
		   }
    ACCESS  write-only
    STATUS  optional
    DESCRIPTION
                "The state of this print data channel. The value
                determines whether control information and print data is
                allowed through this channel or not.
                Additional information:
                This object is for use by the I/O card only. After telling the 
                		peripheral how many logical channels will be used, the MIO 
                		card tells the printer the state of each of the channels.  
                		The state can change from time to time. The state information 
                		is passed using the channelState object. Values are saved by 
                		the peripheral and reported when users request the value of 
                		prtChannelState."
::= { channelEntry 4 }
               
               
channelifindex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  write-only
    STATUS  optional
    DESCRIPTION
                "The value of ifIndex which corresponds to this channel.
                Additional information:
                This object is for use by the I/O card only. After telling 
                		the peripheral how many logical channels will be used, 
                		the MIO card tells the printer the value of the IfIndex 
                		for each channel. The IfIndex is used as part of MIB-II. 
                		The values are saved by the peripheral and reported when 
                		users request the value of prtChannelIfIndex."
::= { channelEntry 5 }
               
               
channelstatus OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  write-only
    STATUS  optional
    DESCRIPTION
                "Sub-unit status is reported in the entries of the
                principle table in the Group that represents the sub-
                unit. For sub-units that report a status, there is a
                status column in the table and the value of this column
                is always an integer formed in the following way.  
                The SubUnitStatus is an integer that is the sum of 5
                distinct values, Availability, Non-Critical, Critical,
                On-line, and Transitioning.  These values are:  
                Availability                      value  
                  Available and Idle              0       000'b  
                  Available and Standby           2       010'b  
                  Available and Active            4       100'b  
                  Available and Busy              6       110'b  
                  Unavailable and OnRequest       1       001'b  
                  Unavailable because Broken      3       011'b  
                  Unknown                         5       101'b  
                Non-Critical  
                  No Non-Critical Alerts          0  
                  Non-Critical Alerts             8  
                Critical  
                  No Critical Alerts              0  
                  Critical Alerts                 16  
                On-Line  
                  Intended state is On-Line       0  
                  Intended state is Off-Line      32  
                Transitioning  
                  At intended state               0  
                  Transitioning to intended state 64
                Additional information:
                This object is for use by the I/O card only. After telling 
                		the peripheral how many logical channels will be used, 
                		the MIO card tells the printer the status of each of 
                		the channels. The status can change from time to time.  
                		The status information is passed using the channelStatus 
                		object. Values are saved by the peripheral and reported 
                		when users request the value of prtChannelStatus."
::= { channelEntry 6 }
               
               
pe-test-button-press OBJECT-TYPE
    SYNTAX  INTEGER {
		   eButton1Pressed(1),
		   eButton2Pressed(2),
		   eButton3Pressed(3),
		   eButton4Pressed(4),
		   eButton5Pressed(5),
		   eButton6Pressed(6),
		   eButton7Pressed(7),
		   eButton8Pressed(8),
		   eButton9Pressed(9),
		   eButton10Pressed(10)
		   }
    ACCESS  write-only
    STATUS  optional
    DESCRIPTION
                "OBSOLETE!  Use CONTROL-PANEL-BUTTON-PRESS instead.  
                Writing this object simulates pressing a front panel
                button.  The mapping of a value to a device's front
                panel button is device specific.  For example, in the
                LaserJet 5Si product, the mapping is:  
                eButton1Pressed - Online  
                eButton2Pressed - Menu  
                eButton3Pressed - Item  
                eButton4Pressed - Plus  
                eButton5Pressed - Select  
                This object should not be in the print engine test sub-
                tree, but the implementing engineer made up an OID,
                instead of getting one assigned.  Please don't do that!"
::= { print-engine-test 6 }
               
               
prtgeneralconfigchanges OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Counts configuration changes that change the capabilities of
        a printer, such as the addition/deletion of input/output bins,
        the addition/deletion of interpreters, or changes in media
        size.  Such changes will often affect the capability of the
        printer to service certain types of print jobs.
        Management applications may cache infrequently changed
        configuration  information about sub-units on the printer.
        This object should be incremented whenever the agent wishes
        such applications to invalidate that cache and re-download
        all of this configuration information, thereby signaling a
        change in the printer's configuration.
	
        For example, if an input tray that contained paper of
        different dimensions was added, this counter would be
        incremented.
        As an additional example, this counter would not be
        incremented when an input tray is removed or the level of an
		input device changes.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                This is a 32 bit counter (unsigned). When it reaches 
                its maximum value, it will roll to zero."
::= { prtGeneralEntry 1 }
               
               
prtgeneralcurrentlocalization OBJECT-TYPE
    SYNTAX  INTEGER(1..11)
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "The value of the prtLocalizationIndex corresponding to the
        current language, country, and character set to be used for
        localized string values that are identified as being dependent
        on the value of this object.  Note that this object does not
        apply to localized strings in the prtConsole group or to any
        object that is not explicitly identified as being localized
        according to prtGeneralCurrentLocalization.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Replaces PML LOCALIZATION-LANGUAGE.  
                The value of this object is saved in NVRAM."
::= { prtGeneralEntry 2 }
               
               
prtgeneralreset OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePnotResetting(3),
		   ePpowerCycleReset(4),
		   ePresetToNVRAM(5),
		   ePresetToFactoryDefaults(6)
		   }
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "Setting this value to `powerCycleReset', `resetToNVRAM', or
        `resetToFactoryDefaults' will result in the resetting of the
        printer.  When read, this object will always have the value
        `notResetting(3)', and a SET of the value `notResetting' shall
        have no effect on the printer.  Some of the defined values are
        optional.  However, every implementation must support at least
        the values `notResetting' and 'resetToNVRAM'.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Replaces PML USER-NVRAM-RESET and POWER-ON-RESET.  
                		All resets follow the same sequence of events except that a 
                		a value of ePresetToFactoryDefaults first makes a call to 
                		reset the NVRAM to factory defaults. Then, the following 
                		sequence of events occur:  
                		1. A delay is initiated while a reply is returned to the 
                		requestor indicating OK.   
                		2. The printer goes off-line.  
                		3. The control panel is disabled.  
                		4. The paper path is flushed.  
                		5. The printer is reset per the request. The printer will 
                		respond to PML requests up to this point in time.  
                		Setting this object to ePpowerCycleReset causes Color LaserJet8550 to 
                		perform its power on initialization routines. I/O cards are 
                		reset (NVRAM on the cards is not changed; all I/O buffers are 
                		flushed). 
                		The tests normally run at power on time are executed.  
                		Setting this object to ePresetToNVRAM causes the printer to 
                		reset itself to its power on state without doing its normal 
                		power on testing. The I/O cards are not reset and I/O buffers 
                		remain intact.  
                		Setting this object to ePresetToFactoryDefaults causes the 
                		same action as a Cold Reset operation performed at the control 
                		panel (except power on testing is not performed). 
                		The I/O cards are not reset and I/O buffers remain intact."
::= { prtGeneralEntry 3 }
               
               
prtgeneralcurrentoperator OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..32))
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "The name of the person who is responsible for operating
          this printer. It is suggested that this string include
          information that would enable other humans to reach the operator,
          such as a phone number. As a convention to facilitate automatic
          notification of the operator by the agent or the network
          management station, the phone number, fax number or email address
          should be placed on a separate line starting with ASCII LF (hex
          0x0A) and the ASCII text string (without the quotes): 'phone: ',
          'fax: ', and 'email: ', respectively. Phone numbers may contain
          digits, whitespace and parentheses, which shall be ignored. Phone
          numbers may also include ASCII comma characters(hex 2C) that are
          used to indicate a two-second pause during the dialing sequence.
          If either the phone, fax, or email information is not available,
          then a line should not be included for this information.
          NOTE: For interoperability purposes, it is advisable to use email
          addresses formatted according to RFC 822 requirements.
	 Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Replaces PML SYSTEM-CONTACT.  
                The maximum
                supported string length is 32 characters.  If the user
                entered string is too long, the device will store as
                much as possible and will return the
                <noError> status.  
                This object is saved in NVRAM."
::= { prtGeneralEntry 4 }
               
               
prtgeneralserviceperson OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..32))
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "The name of the person responsible for servicing this
          printer. It is suggested that this string include information
          that would enable other humans to reach the service person, such
          as a phone number. As a convention to facilitate automatic
          notification of the service person by the agent or a network
          management station, the phone number, fax number or email address
          should be placed on a separate line starting with ASCII LF (hex
          0x0A) and the ASCII text string (without the quotes): 'phone: ',
          'fax: ', and 'email: ', respectively. Phone numbers may contain
          digits, whitespace and parentheses, which shall be ignored. Phone
          numbers can also include one or more ASCII comma characters(hex
          2C) to indicate a two-second pause during the dialing sequence.
          If either the phone,fax, or email information is not available,
          then a line should not included for this information.
          NOTE: For interoperability purposes, it is advisable to use email
          addresses formatted according to RFC 822 requirements.
		
	 Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Replaces PML SYSTEM-CONTACT.  
                The maximum
                supported string length is 32 characters.  If the user
                entered string is too long, the device will store as
                much as possible and will return the
                <noError> status.  
                This object is saved in NVRAM."
::= { prtGeneralEntry 5 }
               
               
prtinputdefaultindex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The value of prtInputIndex corresponding to the default input
        sub-unit: that is, this object selects the default source of
        input media. 
   This value shall be -1 if there is no default input subunit specified
   for the printer as a whole.  In this case, the actual default
   input subunit may be specified by means outside the scope of this
   MIB, such as by each interpreter in a printer with multiple
   interpreters.
   Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                The default input tray is determined by the printer 
                		based on DEFAULT-MEDIA-SIZE and DEFAULT-MEDIA-NAME. If multiple
                		trays have qualifying media, tray 1 is selected first, then the
                		non-empty tray with the highest capacity is selected; trays of 
                		equal capacity are selected by lower tray number.   
                		Trays 1-3 refer to the printer's trays that are so labeled. 
                		Tray 4 is the first tray of the first external input paper
                		handling device."
::= { prtGeneralEntry 6 }
               
               
prtoutputdefaultindex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "The  value of prtOutputIndex  corresponding to the default
        output sub-unit; that is, this object selects the default
        output destination. 
   This value shall be -1 if there is no default output subunit specified
   for the printer as a whole.  In this case, the actual default
   output subunit may be specified by means outside the scope of this
   MIB, such as by each interpreter in a printer with multiple
   interpreters.
   
   Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtGeneralEntry 7 }
               
               
prtmarkerdefaultindex OBJECT-TYPE
    SYNTAX  INTEGER(1..65535)
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The value of prtMarkerIndex corresponding to the
        default marker sub-unit; that is, this object selects the
        default marker.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtGeneralEntry 8 }
               
               
prtmediapathdefaultindex OBJECT-TYPE
    SYNTAX  INTEGER(1..3)
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "The value of prtMediaPathIndex corresponding to
        the default media path; that is, the selection of the
        default media path.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtGeneralEntry 9 }
               
               
prtconsolelocalization OBJECT-TYPE
    SYNTAX  INTEGER(1..16)
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "The value of the prtLocalizationIndex corresponding to
        the language, country, and character set to be used for the
        console.  This localization applies both to the actual display
        on the console as well as the encoding of these console
        objects in management operations.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Replaces PML LOCALIZATION-LANGUAGE.  
                		The value of this object is saved in NVRAM.  
                		If a localized string is currently being displayed on the 
                		control panel by the device, changing this object will cause
                		the displayed string to be changed to its new value. If this 
                		object is changed while the printer is processing a page that 
                		contains localized strings has started, the results are 
                		undefined."
::= { prtGeneralEntry 10 }
               
               
prtconsolenumberofdisplaylines OBJECT-TYPE
    SYNTAX  INTEGER(0..65535)
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The number of lines on the printer's physical
        display.  This value is 0 if there are no lines on the
        physical display or if there is no physical display
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Replaces PML DISPLAY-NUMBER-OF-ROWS.
                		The printer has two physical lines on the display, however,
                		in many cases up to eight seperate lines of text may be
                		displayed by alternating pairs of lines every three seconds.
                		Thus the display really has eight logical lines for displaying 
                		messages. This object will return the number of logical display
                		lines supported by the printer."
::= { prtGeneralEntry 11 }
               
               
prtconsolenumberofdisplaychars OBJECT-TYPE
    SYNTAX  INTEGER(0..65535)
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The number of characters per line displayed on the physical
        display.  This value is 0 if there are no lines on the
        physical display or if there is no physical display
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Replaces PML DISPLAY-COLUMN-SIZE."
::= { prtGeneralEntry 12 }
               
               
prtconsoledisable OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePoperatorConsoleEnabled(3),
		   ePoperatorConsoleDisabled(4),
		   ePoperatorConsoleEnabledLevel1(5),
		   ePoperatorConsoleEnabledLevel2(6)
		   }
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "If the object prtConsoleDisable has value
          'operatorConsoleDisabled' then input is not accepted from the
          operator console. If the object prtConsoleDisable has the value
          'operatorConsoleEnabled' then input is accepted from the
          operator console. If the object prtConsoleDisable has the value
          'operatorConsoleEnabledLevel1','operatorConsoleEnabledLevel2' or
          'operatorConsoleEnabledLevel3' then limited input is accepted
          from the operator console; the limitations are product specific,
          however, the limitations are generally less restrictive for
          operatorConsoleEnabledLevel1 than for
          operatorConsoleEnabledLeve2, which is less restrictive than
          operatorConsoleEnabledLevel3.
          The value of the prtConsoleDisable object is a type-2
          enumeration.
        Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Replaces PML CONTROL-PANEL-LOCK.  
                If the object prtConsoleDisable has value 
                			'ePoperatorConsoleDisabled' then manual input is not 
                			accepted from the operator console. If the object 
                			prtConsoleDisable has the value 
                			'ePoperatorConsoleEnabled' then manual input is 
                			accepted from the operator console.  
                			
                			The following menus are locked with these corresponding
                			values:
                			ePoperatorConsoleEnabled (no locking)  
                			ePoperatorConsoleEnabledLevel1 (minimal locking)  
                			 RESETS MENU  
                			 CONFIGURATION MENU  
                			 I/O MENU  
                			 CALIBRATION MENU  
                
                			ePoperatorConsoleEnabledLevel2 (moderate locking)
                			 PAPER HANDLING MENU  
                			 menus in level 1  
                
                			ePoperatorConsoleDisabled (maximum locking)
                			 PRINTING MENU
                			 INFORMATION MENU
                			 Job Cancel
                			 menus in Levels 1 and 2."
::= { prtGeneralEntry 13 }
               
               
prtgeneralbannerpage OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePnotPresent(5)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Used to enable or disable printing banner pages at the
		 beginning of jobs. This is a master switch which applies
		 to all jobs, regardless of interpreter.
		 Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtGeneralEntry 15 }
               
               
prtcoverdescription OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..255))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The manufacturer provided cover sub-mechanism  name in the
        localization specified by prtGeneralCurrentLocalization.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtCoverEntry 2 }
               
               
prtcoverstatus OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePCoverOpen(3),
		   ePCoverClosed(4)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The status of this cover sub-unit.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Replaces PML NOT-READY-DOOR-OPEN."
::= { prtCoverEntry 3 }
               
               
prtlocalizationlanguage OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..2))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "A two character language code from ISO 639.  Examples
          en, gb, ca, fr, de.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                The languages supported by Color LaserJet8550 are English,
                		French, German, Italian, Spanish, Swedish, Danish, Norwegian, 
                		Dutch, Finnish, and Portuguese."
::= { prtLocalizationEntry 2 }
               
               
prtlocalizationcountry OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..2))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "A two character country code from ISO 3166, a blank string
        (two space characters) shall indicate that the country is
        not defined.  Examples: US, FR, DE, ...
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                The languages supported by Color LaserJet8550 (and corresponding
                		country) are English (United States), French (France), German 
                		(Germany), Italian (Italy), Spanish (Spain), Swedish (Sweden), 
                		Danish (Denmark), Norwegian (Norway), Dutch (Netherlands), 
                		Finnish (Finland), Portuguese (Portugal), Turkish (Turkey), 
                		Polish (Poland), Russian (Russia), Czech (Czechoslovakia),
                		Hungarian (Hungary)."
::= { prtLocalizationEntry 3 }
               
               
prtlocalizationcharacterset OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePcsHPRoman8(2004)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The coded character set used for this localization.
      Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtLocalizationEntry 4 }
               
               
prtstoragerefindex OBJECT-TYPE
    SYNTAX  INTEGER(1..65535)
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The value of the hrDeviceIndex of the printer device that this
        storageEntry is associated with.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtStorageRefEntry 2 }
               
               
prtdevicerefindex OBJECT-TYPE
    SYNTAX  INTEGER(1..65535)
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The value of the hrDeviceIndex of the printer device that this
        deviceEntry is associated with.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtDeviceRefEntry 2 }
               
               
prtinputtype OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePother(1),
		   ePunknown(2),
		   ePsheetFeedAutoRemovableTray(3),
		   ePsheetFeedAutoNonRemovableTray(4),
		   ePsheetFeedManual(5),
		   ePcontinuousRoll(6),
		   ePcontinuousFanFold(7)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The type of technology (discriminated primarily according to
        feeder mechanism type) employed by the input sub-unit.  Note,
        the Optional Input Class provides for a descriptor field to
        further qualify the other choice.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Tray 1 is the multi-purpose tray and is always present. 
                Tray 1 can operate in manual feed mode and supports 
                			both sheets and envelopes. its type is 
                			ePsheetFeedAutoNonRemovableTray.  
                			Color LaserJet8550 base model does not support tray 2. 
                			Trays 2 (8550 N and up) and 3 are the 
                			drawers and, although they are usually not removed 
                			from the printer, the printer cannot distinguish the 
                			open and removed conditions. Therefore, when they are 
                			open, they are considered to be removed and, for 
                			this object, they are considered to be of type 
                			ePsheetFeedAutoRemovableTray.  
                Tray 4 is the high capacity input device. ."
::= { prtInputEntry 2 }
               
               
prtinputdimunit OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePtenThousandthsOfInches(3),
		   ePmicrometers(4)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The unit of measurement for use calculating and relaying
         dimensional values for this input sub-unit.
	 Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtInputEntry 3 }
               
               
prtinputmediadimfeeddirdeclared OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "This object provides the value of the declared dimension, in
        the feed direction, of the media that is (or, if empty, was or
        will be) in this input sub-unit.  The feed direction is the
        direction in which the media is fed on this sub-unit.  This
        dimension is measured in input sub-unit dimensional units
        (prtInputDimUnit).  If this input sub-unit can reliably sense
        this value, the value is sensed by the printer and may not be
        changed by management requests.  Otherwise, the value may be
        changed. The value (-1) means other and specifically means
        that this sub-unit places no restriction on this parameter.
        The value (-2) indicates unknown.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                For trays 2 (8550 N and up), 3 and 4 (which can 
                		reliably sense this value) the objects behave exactly the 
                		same as prtInputMediaDimFeedDirChosen. 
                		Attempting to set this object for trays 2, 3 and 4 will cause 
                		<noSuchName> to be returned.
                		The default values assume the trays are configured for 
                		letter size paper.  
                		For tray 1 the value is the dimension for the media size 
                		currently declared."
::= { prtInputEntry 4 }
               
               
prtinputmediadimxfeeddirdeclared OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "This object provides the value of the declared dimension, in
        the cross feed direction, of the media that is (or, if empty,
        was or will be) in this input sub-unit.  The cross  feed
        direction is ninety degrees relative to the feed direction
        associated with this sub-unit. This dimension is measured in
        input sub-unit dimensional units (prtInputDimUnit).  If this
        input sub-unit can reliably sense this value, the value is
        sensed by the printer and may not be changed by management
        requests. Otherwise, the value may be changed. The value (-1)
        means other and specifically means that this sub-unit places
        no restriction on this parameter. The value (-2) indicates
        unknown.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                For trays 2 (8550 N and up), 3 and 4 (which can 
                		reliably sense this value) the objects behave exactly the 
                		same as prtInputMediaDimXFeedDirChosen.   
                		Attempting to set this object for trays 2, 3 and 4 will cause 
                		<noSuchName> to be returned.
                		The default values assume the trays are configured for 
                		letter size paper.  
                		For tray 1 the value is the dimension for the media size 
                		currently declared."
::= { prtInputEntry 5 }
               
               
prtinputmediadimfeeddirchosen OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The printer will act as if media of the chosen dimension (in
        the feed direction) is present in this input source.  Note
        that this value will be used even if the input tray is empty.
        Feed dimension measurements are taken relative to the feed
        direction associated with that sub-unit and are in input sub-unit
        dimensional units (MediaUnit). If the printer supports the
        declared dimension, the granted dimension is the same as
        the declared dimension. If not, the granted dimension is
        set to the closest dimension that the printer supports
        when the declared dimension is set. The value (-1) means
        other and specifically indicates that this sub-unit
        places no restriction on this parameter. The value (-2)
        indicates unknown.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                The objects for trays 2 (8550 N and up), 3 and 4 
                		reflect the configuration of the corresponding drawers. 
                			When the drawer is open, a value of -2 is returned. 
                			The default values assume the trays are configured for 
                			letter size paper.  
                			The object for trays 1 returns the value of the 
                			media size for which the tray is currently configured."
::= { prtInputEntry 6 }
               
               
prtinputmediadimxfeeddirchosen OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The printer will act as if media of the chosen dimension (in
        the cross feed direction) is present in this input source.
        Note that this value will be used even if the input tray is
        empty.  The cross feed direction is ninety degrees relative
        to the feed direction associated with this sub-unit. This
        dimension is measured in input sub-unit dimensional units
        (MediaUnit).  If the printer supports the declared
        dimension, the granted dimension is the same as the
        declared dimension. If not, the granted dimension is set
        to the closest dimension that the printer supports when
        the declared dimension is set. The value (-1) means other
        and specifically indicates that this sub-unit places no
        restriction on this parameter.  The value (-2) indicates
        unknown.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                The objects for trays 2 (8550 N and up), 3 and 4 
                		reflect the configuration of the corresponding drawers. 
                		When the drawer is open, a value of -2 is returned. 
                		The default values assume the trays are configured for letter 
                		size paper.  
                		The object for trays 1 returns the value of the media 
                		size for which the tray is currently configured."
::= { prtInputEntry 7 }
               
               
prtinputcapacityunit OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePtenThousandthsOfInches(3),
		   ePmicrometers(4),
		   ePsheets(8),
		   ePfeet(16),
		   ePmeters(17)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The unit of measurement for use in calculating and relaying
        capacity values for this input sub-unit.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                A sheet is a single piece of 20 pound paper. "
::= { prtInputEntry 8 }
               
               
prtinputmaxcapacity OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The maximum capacity of the input sub-unit in input
        sub-unit capacity units (PrtCapacityUnitTC).  There is no
        convention associated with the media itself so this value
        reflects claimed capacity. If this input sub-unit can
        reliably sense this value, the value is sensed by the
        printer and may not be changed by management requests;
        otherwise, the value may be written (by a Remote
        Control Panel or a Management Application).
        The value (-1) means other and specifically
        indicates that the sub-unit places no restrictions
        on this parameter.  The value (-2) means unknown.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Replaces PML TRAYn-MAXIMUM-CAPACITY.
                		Color LaserJet8550 base model does not support tray 2.
                		The max capacity of the Matterhorn HCI is 1000."
::= { prtInputEntry 9 }
               
               
prtinputcurrentlevel OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The current capacity of the input sub-unit in input
        sub-unit capacity units (PrtCapacityUnitTC). If this input
        sub-unit can reliably sense this value, the value is
        sensed by the printer and may not be changed by
        management requests; otherwise, the value may
        be written (by a Remote Contol Panel or a
        Management Application).  The value (-1) means other and
        specifically indicates that the sub-unit places no
        restrictions on this parameter. The value (-2) means unknown.
        The value (-3) means that the printer knows that at least one
        unit remains.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                For trays 1, Color LaserJet8550 can only detect empty/not 
                empty trays. It returns -3 for not empty and 0 for 
                empty.  
                			For trays 2 (8550 N and up) and 3, Color LaserJet8550 can detect 
                			approximately the amount of media. The value returned 
                			is based on the amount detected as follows:  
                			0 - empty   
                			1 - 1-110 sheets  
                			50 - 50-260 sheets  
                			200 - 200-490 sheets  
                			430 - 430 sheets or more  
                			For tray 4, Color LaserJet8550 can detect approximately the amount 
                			of media. The value returned is based on the amount 
                			detected as follows:  
                			0 - empty   
                			1 - 1 sheet to 25% of capacity  
                			500 - 26% to 50% of capacity  
                			1000 - 51% to 75% of capacity  
                			1500 - 76% to 100% of capacity  
                			If the tray drawer is open, a value of -2 (unknown) 
                			will  be returned."
::= { prtInputEntry 10 }
               
               
prtinputstatus OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The current status of this input sub-unit.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Replaces PML STATUS-TRAY-MISSING and
                STATUS-TRAY-EMPTY.  
                		See SubUnitStatus in RFC1759 Printer MIB for details on 
                		values reported by this object. Color LaserJet8550 will not include 
                		values Available and Standby (2), Available and Active (4) 
                		or Unknown (5)."
::= { prtInputEntry 11 }
               
               
prtinputmedianame OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..63))
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "A description of the media contained in this input sub-unit;
        This description is intended for display to a human operator.
        This description is not processed by the printer.  It is used
        to provide information not expressible in terms of the other
        media attributes (e.g. prtInputMediaDimFeedDirChosen,
        prtInputMediaDimXFeedDirChosen, prtInputMediaWeight,
        prtInputMediaType). An example would be `legal tender bond
        paper'.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Replaces PML TRAYn-MEDIA-NAME.  
                		If set to a string other than one contained by a MEDIAn-NAME 
                		object, a status of <badValue> is 
                		returned."
::= { prtInputEntry 12 }
               
               
prtinputname OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..63))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The name assigned to this input sub-unit.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Replaces PML TRAYn-NAME."
::= { prtInputEntry 13 }
               
               
prtinputvendorname OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..63))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The vendor name of this input sub-unit.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtInputEntry 14 }
               
               
prtinputmodel OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..63))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The model name of this input sub-unit.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Replaces PML objects PHDn-MODEL.
                			Color LaserJet8550 base model does not support tray 2."
::= { prtInputEntry 15 }
               
               
prtinputversion OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..63))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The version of this input sub-unit.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Replaces PML objects PHDn-MANUFACTURING-INFO.
                			Color LaserJet8550 base model does not support tray 2."
::= { prtInputEntry 16 }
               
               
prtinputserialnumber OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..63))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The serial number assigned to this input sub-unit.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtInputEntry 17 }
               
               
prtinputdescription OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..255))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "A free-form text description of this input
        sub-unit in the localization specified by
        prtGeneralCurrentLocalization.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtInputEntry 18 }
               
               
prtinputsecurity OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePother(1),
		   ePon(3),
		   ePoff(4),
		   ePnotPresent(5)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Indicates if this input sub-unit has some security
        associated with it.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                No security mechanism provided."
::= { prtInputEntry 19 }
               
               
prtoutputtype OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePother(1),
		   ePunknown(2),
		   ePremovableBin(3),
		   ePunRemovableBin(4),
		   ePcontinuousRollDevice(5),
		   ePmailBox(6),
		   ePcontinousFanFold(7)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The type of technology supported by this output sub-unit.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtOutputEntry 2 }
               
               
prtoutputcapacityunit OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePtenThousandthsOfInches(3),
		   ePmicrometers(4),
		   ePsheets(8),
		   ePfeet(16),
		   ePmeters(17)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The unit of measurement for use in calculating and relaying
        capacity values for this output sub-unit.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                A sheet is a single piece of 20 pound paper."
::= { prtOutputEntry 3 }
               
               
prtoutputmaxcapacity OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The maximum capacity of this output sub-unit in output
        sub-unit capacity units (PrtCapacityUnitTC). There is no
        convention associated with the media itself so this value
        essentially reflects claimed capacity. If this output
        sub-unit can reliably sense this value, the value is
        sensed by the printer and may not be changed by management
        requests; otherwise, the value may be written
        (by a Remote Control Panel or a Management Application).
        The value (-1) means other and specifically indicates
        that the sub-unit places no restrictions on this parameter.
        The value (-2) means unknown.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Replaces PML OUTBINn-MAXIMUM-CAPACITY.  
                	Output sub-unit 2 is not supported if any output paper 
                		handling device is attached.  
                		The capacity of sub-unit 4 depends on the mode of operation. 
                		The capcities are as follows:  
                		Stacker: 3000 letter papers (sub-units 5-11 do not exist)  
                		Job Separator: 250 (sub-units 5-11 do not exist)  
                		Stapler: 125 (sub-units 5 - 11 do not exist)   
                		Mailbox: 250 (this is the default mode)"
::= { prtOutputEntry 4 }
               
               
prtoutputremainingcapacity OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The remaining capacity of the possible output sub-unit
        capacity in output sub-unit capacity units (PrtCapacityUnitTC)
        of this output sub-unit. If this output sub-unit can
        reliably sense this value, the value is sensed by the
        printer and may not be modified by management requests;
        otherwise, the value may be written (by
        a Remote Control Panel or a Management
        Application).  The value (-1) means other and
        specifically indicates that the sub-unit places no
        restrictions on this parameter.  The value (-2) means
        unknown.  The value (-3) means that the printer knows that
        there remains capacity for at least one unit.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Replaces PML NOT-READY-OUTBIN-FULL and
                STATUS-OUTBIN-FULL.  
                		The values reported for output sub-unit 1 (face-down, top bin) 
                		will be either (-3) if it is not full or (0) if it is full.   
                		Output sub-unit 2 (face-up, left side bin) does not have any 
                		sensing, so it will always report unknown (-2).  
                		The first output sub-unit (3) of the HCO reports either (62) 
                		if it is not full, (125) when empty, or (0) if it is full.  
                		In mailbox mode, the HCO sub-units (4-11) will report (250) 
                		when empty, (125) when there's room for <250 sheets and (0) 
                		when full.  
                		In stacker and job separator modes all bins are treated as a 
                		single output bin so sub-unit 4 will report (2000) when all 
                		bins are empty. A value of (0) is reported when the topmost 
                		bin is full (stacker mode) or when a bins is full 
                		(separator mode).  
                		When the stacker or separator has started filling, the value 
                		reported is based on the number of bins that are empty, 
                		partially filled and full. 
                		A percentage is calculated based on the status of each bin. 
                		Each full bin counts 1, each not empty/not full bin counts 
                		0.5 and each empty bin counts 0. The result is mapped to an 
                		estimate of the remaining capacity as follows (percent full 
                		is included here for completeness, since that is how the 
                		HCO reports it to the printer):  
                		0.0 2000  (100%)  
                		0.5 1900  ( 90%)  
                		1.0 1800  ( 85%)  
                		1.5 1700  ( 80%)  
                		2.0 1500  ( 75%)  
                		2.5 1400  ( 65%)  
                		3.0 1300  ( 60%)  
                		3.5 1200  ( 55%)  
                		4.0 1000  ( 50%)  
                		4.5  900  ( 40%)  
                		5.0  800  ( 35%)  
                		5.5  700  ( 30%)  
                		6.0  500  ( 25%)  
                		6.5  400  ( 15%)  
                		7.0  300  ( 10%)  
                		7.5  200  (  5%)  
                		8.0    0  (  0%)  
                		Note: Due to HCO mechanism limitations, the value reported may 
                		not always be accurate (the bin status is detected only when 
                		the media delivery head is moved to or past a physical bin). 
                		Also, for stacker mode a bin is considered full as long as any 
                		bin above it is not empty.  
                		Default values assume all sub-units are empty and the HCO is 
                		in mailbox mode."
::= { prtOutputEntry 5 }
               
               
prtoutputstatus OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The current status of this output sub-unit.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Replaces PML NOT-READY-OUTBIN-MISSING and
                STATUS-OUTBIN-MISSING.  
                		The default values assume all bins are empty.   
                		See SubUnitStatus in RFC1759 Printer MIB for details on 
                		values reported by this object. Color LaserJet8550 will not include 
                		values Available and Standby (2), Available and Active (4), 
                		Unknown (5) or Transitioning to intended state (64)."
::= { prtOutputEntry 6 }
               
               
prtoutputname OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..19))
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "The name assigned to this output sub-unit.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Replaces PML OUTBINn-NAME.  
                		The characters must be in the range 20H to 7FH except 5C. 
                		When this string is displayed on the control panel the 
                		Roman-8 symbol set is used.  
                		The object for bin 2 is not available when the HCO is attached."
::= { prtOutputEntry 7 }
               
               
prtoutputvendorname OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..63))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The vendor name of this output sub-unit.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                "
::= { prtOutputEntry 8 }
               
               
prtoutputmodel OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..63))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The name assigned to this output sub-unit.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                The value returned by this object depends on the 
                		current mode of the device. 
                		The possible values are as follows:  
                		MULTIBIN MAILBOX C4785A  
                		MULTIBIN STACKER C4785A  
                		MULTIBIN SEPARATOR C4785A  
                		STAPLER MODULE C3766A."
::= { prtOutputEntry 9 }
               
               
prtoutputversion OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..63))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The version of this output sub-unit.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Returns device-specific information about the configuration 
                of the output bin. May include information about the type of 
                processing that can be done to media sent to this bin; 
                processing includes but is not limited to binding, punching, 
                folding and sealing. Format of this object is specified by 
                the output device documentation."
::= { prtOutputEntry 10 }
               
               
prtoutputserialnumber OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..63))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The serial number assigned to this output sub-unit.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtOutputEntry 11 }
               
               
prtoutputdescription OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..255))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "  A free-form text description of this output sub-unit in the
        localization specified by prtGeneralCurrentLocalization.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtOutputEntry 12 }
               
               
prtoutputsecurity OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePother(1),
		   ePon(3),
		   ePoff(4),
		   ePnotPresent(5)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Indicates if this output sub-unit has some security associated
        with it and if that security is enabled or not.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                No security mechanism provided."
::= { prtOutputEntry 13 }
               
               
prtoutputstackingorder OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePunknown(2),
		   ePfirstToLast(3),
		   ePlastToFirst(4)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The current state of the stacking order for the
        associated output sub-unit. `FirstToLast' means
        that as pages are output the front of the next page is
        placed against the back of the previous page.
        `LasttoFirst' means that as pages are output the back
        of the next page is placed against the front of the
        previous page.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Replaces PML OUTBINn-STACK-ORDER."
::= { prtOutputEntry 19 }
               
               
prtoutputpagedeliveryorientation OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePfaceUp(3),
		   ePfaceDown(4)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The reading surface that will be `up' when pages are
        delivered to the associated output sub-unit. Values are
        faceUp and faceDown. (Note: interpretation of these
        values is in general context-dependent based on locale;
        presentation of these values to an end-user should be
        normalized to the expectations of the user).
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtOutputEntry 20 }
               
               
prtoutputbursting OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePother(1),
		   ePon(3),
		   ePoff(4),
		   ePnotPresent(5)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "This object indicates that the outputting sub-unit
        supports bursting, and if so, whether the feature is enabled.
        Bursting is the process by which continuous media is separated
        into individual sheets, typically by bursting along pre-formed
        perforations.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Bursting is not supported.  
                			For the base, outbins 1 and 2 are supported.
                			In stacker/stapler mode, outbins 1, 3, and 4 are 
                			supported.
                			In MBM mode, outbins 1, 3 - 11 are supported."
::= { prtOutputEntry 21 }
               
               
prtoutputdecollating OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePother(1),
		   ePon(3),
		   ePoff(4),
		   ePnotPresent(5)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "This object indicates that the output supports
        supports decollating, and if so, whether the feature
        is enabled. Decollating is the process by which the
        individual parts within a multi-part form are separated
        and sorted into separate stacks for each part.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Decollating is not supported."
::= { prtOutputEntry 22 }
               
               
prtoutputpagecollated OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePother(1),
		   ePon(3),
		   ePoff(4),
		   ePnotPresent(5)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "This object indicates that the output sub-unit
        supports page collation, and if so, whether the feature is
        enabled. See glossary for definition of how this document defines
        collation.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtOutputEntry 23 }
               
               
prtoutputoffsetstacking OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePother(1),
		   ePon(3),
		   ePoff(4),
		   ePnotPresent(5)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "This object indicates that the output supports
        supports offset stacking, and if so, whether the feature is
        enabled. See glossary for how Offset Stacking is defined by this
        document.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtOutputEntry 24 }
               
               
prtmarkermarktech OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePother(1),
		   ePunknown(2),
		   ePelectrophotographicLED(3),
		   ePelectrophotographicLaser(4),
		   ePelectrophotographicOther(5),
		   ePimpactMovingHeadDotMatrix9pin(6),
		   ePimpactMovingHeadDotMatrix24pin(7),
		   ePimpactMovingHeadDotMatrixOther(8),
		   ePimpactMovingHeadFullyFormed(9),
		   ePimpactBand(10),
		   ePimpactOther(11),
		   ePinkjetAqueous(12),
		   ePinkjetSolid(13),
		   ePinkjetOther(14),
		   ePpen(15),
		   ePthermalTransfer(16),
		   ePthermalSensitive(17),
		   ePthermalDiffusion(18),
		   ePthermalOther(19),
		   ePelectroerosion(20),
		   ePelectrostatic(21),
		   ePphotographicMicrofiche(22),
		   ePphotographicImagesetter(23),
		   ePphotographicOther(24),
		   ePionDeposition(25),
		   ePeBeam(26),
		   ePtypesetter(27)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The type of marking technology used for this marking sub-unit.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtMarkerEntry 2 }
               
               
prtmarkercounterunit OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePtenThousandthsOfInches(3),
		   ePmicrometers(4),
		   ePcharacters(5),
		   ePlines(6),
		   ePimpressions(7),
		   ePsheets(8),
		   ePdotRow(9),
		   ePhours(11),
		   ePfeet(16),
		   ePmeters(17)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The unit that will be used by the printer when reporting
        counter values for this marking sub-unit.  The
        time units of measure are provided for a device like a
        strip recorder that does not or cannot track the physical
        dimensions of the media and does not use characters,
        lines or sheets.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtMarkerEntry 3 }
               
               
prtmarkerlifecount OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The count of the number of units of measure counted during
        the life of printer using units of measure as specified by
        prtMarkerCounterUnit.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Replaces PML TOTAL-ENGINE-PAGE-COUNT.  
                In Color LaserJet8550 it is kept in NVRAM however the NVRAM value 
                			is only updated every 10 impressions. NOTE: The value 
                			returned by this OID will be incremented every page 
                			but if power is lost between NVRAM updates, up to 9 
                			impressions of the page count may be lost.  
                			The counter will be reset to zero after 16,777,215 
                			( 2^24-1) pages.  
                			The page count is incremented when a sheet of media is 
                			pulled from an input tray. A duplex printed sheet will 
                			cause this counter to be incremented by two."
::= { prtMarkerEntry 4 }
               
               
prtmarkerpoweroncount OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The count of the number of units of measure counted since the
        equipment was most recently powered on using units of measure as
        specified by prtMarkerCounterUnit.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtMarkerEntry 5 }
               
               
prtmarkerprocesscolorants OBJECT-TYPE
    SYNTAX  INTEGER(0..65535)
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The number of process colors supported by this marker.  A
        process color of 1 implies monochrome.  The value of this
        object and prtMarkerSpotColorants cannot both be 0.  The value of
        prtMarkerProcessColorants must be 0 or greater.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Color LaserJet8550 has four process colorants: Black, Cyan, Magenta,
                			and Yellow."
::= { prtMarkerEntry 6 }
               
               
prtmarkerspotcolorants OBJECT-TYPE
    SYNTAX  INTEGER(0..65535)
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The number of spot colors supported by this marker.  The
        value of this object and prtMarkerProcessColorants cannot
        both be 0.  Must be 0 or greater.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtMarkerEntry 7 }
               
               
prtmarkeraddressabilityunit OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePtenThousandthsOfInches(3),
		   ePmicrometers(4)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The unit of measure of distances, as applied to the marker's
         resolution.
	 Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtMarkerEntry 8 }
               
               
prtmarkeraddressabilityfeeddir OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The maximum number of addressable marking positions in the feed
        direction per 10000 units of measure specified by
        prtMarkerAddressabilityUnit.  A value of (-1) implies 'other' or
        'infinite' while a value of (-2) implies 'unknown'.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Use this object to specify resolution. Color LaserJet8550 only
                			supports 600 dpi."
::= { prtMarkerEntry 9 }
               
               
prtmarkeraddressabilityxfeeddir OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The maximum number of addressable marking positions in the cross
        feed direction in 10000 units of measure specified by
        prtMarkerAddressabilityUnit.  A value of (-1) implies 'other' or
        'infinite' while a value of (-2) implies 'unknown'.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Use this object to specify resolution. Color LaserJet8550 only
                			supports 600 dpi."
::= { prtMarkerEntry 10 }
               
               
prtmarkernorthmargin OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The margin, in units identified by prtMarkerAddressabilityUnit,
        from the leading edge of the medium as the medium flows
        through the marking engine with the side to be imaged
        facing the observer. The leading edge is the North edge
        and the other edges are defined by the normal compass
        layout of  directions with the compass facing the
        observer.  Printing within the area bounded by all four
        margins is guaranteed for all interpreters.   The value
        (-2) means unknown.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtMarkerEntry 11 }
               
               
prtmarkersouthmargin OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The margin from the South edge  (see prtMarkerNorthMargin)
        of the medium in units identified by
        prtMarkerAddressabilityUnit.  Printing within the area bounded by
        all four margins  is guaranteed for all interpreters.
        The value (-2) means unknown.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtMarkerEntry 12 }
               
               
prtmarkerwestmargin OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The margin from the West edge (see prtMarkerNorthMargin) of the
        medium in units identified by prtMarkerAddressabilityUnit.
        Printing within the area bounded by all four margins is
        guaranteed for all interpreters.   The value (-2) means
        unknown.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtMarkerEntry 13 }
               
               
prtmarkereastmargin OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The margin from the East edge (see prtMarkerNorthMargin) of the
        medium in units identified by prtMarkerAddressabilityUnit.
        Printing within the area bounded by all four margins is
        guaranteed for all interpreters. The value (-2) means
        unknown.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtMarkerEntry 14 }
               
               
prtmarkerstatus OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The current status of this marker sub-unit.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Replaces PML NOT-READY-DESTINATION-PRINT-ENGINE and
                STATUS-DESTINATION-PRINT-ENGINE.  
                			The default value assumes no malfunctions.   
                			See SubUnitStatus in RFC1759 Printer MIB for details 
                			on values reported by this object. Color LaserJet8550 will not 
                			include values Available and Active (4) or Unknown (5)."
::= { prtMarkerEntry 15 }
               
               
prtmarkersuppliesmarkerindex OBJECT-TYPE
    SYNTAX  INTEGER(0..65535)
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The value of prtMarkerIndex corresponding to the
        marking sub-unit with which this marker supply
        sub-unit is associated.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtMarkerSuppliesEntry 2 }
               
               
prtmarkersuppliescolorantindex OBJECT-TYPE
    SYNTAX  INTEGER(0..65535)
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The value of prtMarkerColorantIndex
        corresponding to the colorant with which this
        marker supply sub-unit is associated.  This value
        shall be 0 if there is no colorant table.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtMarkerSuppliesEntry 3 }
               
               
prtmarkersuppliesclass OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePother(1),
		   ePsupplyThatIsConsumed(3),
		   ePreceptacleThatIsFilled(4)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Indicates whether this supply entity represents a supply
        that is consumed or a receptacle that is filled.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtMarkerSuppliesEntry 4 }
               
               
prtmarkersuppliestype OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePother(1),
		   ePunknown(2),
		   ePtoner(3),
		   ePwasteToner(4),
		   ePink(5),
		   ePinkCartridge(6),
		   ePinkRibbon(7),
		   ePwasteInk(8),
		   ePopc(9),
		   ePdeveloper(10),
		   ePfuserOil(11),
		   ePsolidWax(12),
		   ePribbonWax(13),
		   ePwasteWax(14),
		   ePfuser(15),
		   ePcoronaWire(16),
		   ePfuserOilWick(17),
		   ePcleanerUnit(18),
		   ePfuserCleaningPad(19),
		   ePtransferUnit(20),
		   ePtonerCartridge(21),
		   ePfuserOiler(22)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The type of this supply.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtMarkerSuppliesEntry 5 }
               
               
prtmarkersuppliesdescription OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..255))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The description of this supply container/receptacle in the
        localization specified by prtGeneralCurrentLocalization.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtMarkerSuppliesEntry 6 }
               
               
prtmarkersuppliessupplyunit OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePtenThousandthsOfInches(3),
		   ePmicrometers(4),
		   ePimpressions(7),
		   ePsheets(8),
		   ePthousandthsOfOunces(12),
		   ePhours(11),
		   ePtenthsOfGrams(13),
		   ePhundrethsOfFluidOunces(14),
		   ePtenthsOfMilliliters(15),
		   ePfeet(16),
		   ePmeters(17)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Unit of measure of this marker supply container/receptacle.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtMarkerSuppliesEntry 7 }
               
               
prtmarkersuppliesmaxcapacity OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The maximum capacity of this supply container/receptacle
        expressed in prtMarkerSuppliesSupplyUnit. If this supply
        container/receptacle can reliably sense this value, the
        value is reported by the printer and is read-only;
        otherwise, the value may be written (by a Remote Control
        Panel or a Management Application). The value (-1) means
        other and specifically indicates that the sub-unit places
        no restrictions on this parameter. The value (-2) means
        unknown.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtMarkerSuppliesEntry 8 }
               
               
prtmarkersupplieslevel OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The current level if this supply is a container; the
        remaining space if this supply is a receptacle. If this
        supply container/receptacle can reliably sense this
        value, the value is reported by the printer and is
        read-only; otherwise, the value may be written (by a
        Remote Control Panel or a Management Application). The
        value (-1) means other and specifically indicates that
        the sub-unit places no restrictions on this parameter.
        The value (-2) means unknown.  A value of (-3) means that the
        printer knows that there is some supply/remaining space,
        respectively.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Color LaserJet8550 detects two states for the toner: 
                			Between the 'LOW' and 'LOW 2' thresholds will be
                			reported as -2.   
                			At the 'LOW 2' threshold will be reported as 0.  
                			The other consumables will report -2.
                			For Matterhorn, at printer initialization, all 
                			consumables will default to -2. This value will not
                			change since Matterhorn cannot track consumables."
::= { prtMarkerSuppliesEntry 9 }
               
               
prtmediapathmaxspeedprintunit OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePtenThousandthsOfInchesPerHour(3),
		   ePmicrometersPerHour(4),
		   ePcharactersPerHour(5),
		   ePlinesPerHour(6),
		   ePimpressionsPerHour(7),
		   ePsheetsPerHour(8),
		   ePdotRowPerHour(9),
		   ePfeetPerHour(16),
		   ePmetersPerHour(17)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The unit of measure used in specifying the speed of all media
        paths in the printer.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtMediaPathEntry 2 }
               
               
prtmediapathmediasizeunit OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePtenThousandthsOfInches(3),
		   ePmicrometers(4)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The units of measure of media size for use in calculating and
        relaying dimensional values for all media paths in the printer.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtMediaPathEntry 3 }
               
               
prtmediapathmaxspeed OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The maximum printing speed of this media path expressed in
        prtMediaPathMaxSpeedUnit's.  A value of (-1) implies
        'other'.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Replaces PML PRINT-ENGINE-PERFORMANCE.  
                The page size for this performance is 8.5x11."
::= { prtMediaPathEntry 4 }
               
               
prtmediapathmaxmediafeeddir OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The maximum physical media size in the feed direction of this
        media path expressed in units of measure specified by
        PrtMediaPathMediaSizeUnit.  A value of (-1) implies 'unlimited',
        a value of (-2) implies 'unknown'.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                The value returned by this object depends on the value 
                		of prtMediaPathMediaSizeUnit. It is 185000 if 
                		prtMediaPathMediaSizeUnit is ePtenThousandthsOfInches or 
                		469900 if prtMediaPathMediaSizeUnit is ePmicrometers."
::= { prtMediaPathEntry 5 }
               
               
prtmediapathmaxmediaxfeeddir OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The maximum physical media size across the feed direction of
        this media path expressed in units of measure specified by
        prtMediaPathMediaSizeUnit.  A value of (-2) implies 'unknown'.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                The value returned by this object depends on the value 
                		of prtMediaPathMediaSizeUnit. It is 120000 if 
                		prtMediaPathMediaSizeUnit is ePtenThousandthsOfInches or 
                		304800 if prtMediaPathMediaSizeUnit is ePmicrometers."
::= { prtMediaPathEntry 6 }
               
               
prtmediapathminmediafeeddir OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The minimum physical media size in the feed direction of this
        media path expressed in units of measure specified by
        prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                The value returned by this object depends on the value 
                		of prtMediaPathMediaSizeUnit. For the simplex paper path it is 
                		74803 if prtMediaPathMediaSizeUnit is ePtenThousandthsOfInches 
                		or 189999 if prtMediaPathMediaSizeUnit is ePmicrometers. 
                		For the duplex paper path it is 82677 if 
                		prtMediaPathMediaSizeUnit is ePtenThousandthsOfInches or 
                		210000 if prtMediaPathMediaSizeUnit is ePmicrometers.  
                		This sizes correspond to a custom paper length for simplex,
                		A5 paper length for duplex ( Note: The simallest paper size for 		simplex must be fed portrait)."
::= { prtMediaPathEntry 7 }
               
               
prtmediapathminmediaxfeeddir OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The minimum physical media size across the feed direction of
        this media path expressed in units of measure specified by
        prtMediaPathMediaSizeUnit.  A value of (-2) implies 'unknown'.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                The value returned by this object depends on the value 
                		of prtMediaPathMediaSizeUnit. For the simplex paper path, it is
                		38740 if prtMediaPathMediaSizeUnit is ePtenThousandthsOfInches 
                		or 98400 if prtMediaPathMediaSizeUnit is ePmicrometers.  
                		For the duplex paper path it is 58267 if 
                		prtMediaPathMediaSizeUnit is ePtenThousandthsOfInches or
                		148000 if prtMediaPathMediaSizeUnit is ePmicrometers.  	
                		This size corresponds to a custom paper width for the simplex,
                		A5 paper width for duplex."
::= { prtMediaPathEntry 8 }
               
               
prtmediapathtype OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePlongEdgeBindingDuplex(3),
		   ePshortEdgeBindingDuplex(4),
		   ePsimplex(5)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The type of the media path for this media path.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Replaces PML DUPLEX-INSTALLED."
::= { prtMediaPathEntry 9 }
               
               
prtmediapathdescription OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..255))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The manufacturer-provided description of this media path in
        the localization specified by prtGeneralCurrentLocalization.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtMediaPathEntry 10 }
               
               
prtmediapathstatus OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The current status of this media path.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                The default values assume the printer is idle.   
                		See SubUnitStatus in RFC1759 Printer MIB for details on 
                		values reported by this object. Color LaserJet8550 will not include values 
                		Available and Standby (2), Available and Active (4), 
                		Unknown (5), Non-CriticalAlerts (8) or Transitioning 
                		to intended state (64)."
::= { prtMediaPathEntry 11 }
               
               
prtchanneltype OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePother(1),
		   ePchIEEE1284Port(5),
		   ePchAppleTalkPAP(7),
		   ePchNetwarePServer(10),
		   ePchDLCLLCPort(15),
		   ePchBidirPortTCP(38)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The type of this print data channel.  This
        object provides the linkage to ChannelType-specific
        groups that may (conceptually) extend the prtChannelTable
        with additional details about that channel.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                This object, in conjunction with 
                prtChannelProtocolVersion, replaces the PML object 
                PORTn-DESCRIPTION.  
                MIO-based channels provide their own values.
                			There are 34 channel types for Color LaserJet8550; first two being 
                			parallel, 3 - 18 are for the first card, and 19 - 34
                			are for the second card. If a card wants to use all 
                			16 channels at a given time, it can. But a card could 
                			use less than 16 channels at a given time."
::= { prtChannelEntry 2 }
               
               
prtchannelprotocolversion OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..63))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The version of the protocol used on this
        channel.  The format used for version numbering depends
        on prtChannelType.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                This object, in conjunction with 
                		prtChannelType, replaces the PML object PORTn-DESCRIPTION.  
                
                		MIO-based channels provide their own values.  
                		The channel 1 value includes (separated by semi colons) 
                		different aspects of the spec: electrical;logical; and 
                		physical connector."
::= { prtChannelEntry 3 }
               
               
prtchannelcurrentjobcntllangindex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The value of prtInterpreterIndex  corresponding to the
        Control Language Interpreter for this channel. This
        interpreter defines the syntax used for control
        functions, such as querying or changing environment
        variables and identifying job boundaries (e.g. PJL,
        PostScript, NPAP). Must be 1 or greater.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                This object points to the PJL language. It is 
                read-only because PJL (2) is the printer's only job 
                control language. It is the same for all channels."
::= { prtChannelEntry 4 }
               
               
prtchanneldefaultpagedesclangindex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "The value of prtInterpreterIndex  corresponding to the
        Page Description Language Interpreter for this channel.
        This interpreter defines the default Page Description
        Language interpreter to be used for the print data unless
        the Control Language is used to select a specific
        interpreter (e.g.,  PCL, PostScript Language,
        auto-sense). Must be 1 or greater.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Replaces PML DEFAULT-PDL.  
                		The default points to the automatic language switcher. 
                			If this object is changed for one channel, all channels
                			will be changed."
::= { prtChannelEntry 5 }
               
               
prtchannelstate OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePother(1),
		   ePprintDataAccepted(3),
		   ePnoDataAccepted(4)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The state of this print data channel.  The value determines
        whether control information and print data is allowed through
        this channel or not.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                MIO-based channels provide their own values for this 
                		object.  
                		The base-printer's port always reports a value of 
                		ePprintDataAccepted. If the printer is offline, that is 
                		detected by reading the Host Resources General Printer Status 
                		objects, not by reading this object."
::= { prtChannelEntry 6 }
               
               
prtchannelifindex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The value of ifIndex (in the ifTable; see the interface
        section of MIB-2/RFC 1213) which corresponds to this channel.
        When more than one row of the ifTable is relevant, this is
        the index of the row representing the topmost layer in the
        interface hierarchy.  A value of zero indicates that no
        interface is associated with this channel.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                MIO-based channels provide their own values for 
                		this object."
::= { prtChannelEntry 7 }
               
               
prtchannelstatus OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The current status of the channel.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                See SubUnitStatus in RFC1759 Printer MIB for details 
                		on values reported by this object. MIO-based channels provide 
                		their own values for this object. Status for Color LaserJet8550's parallel 
                		port will not include values Available and Standby (2), 
                		Available and Active (4), Non-Critical Alerts (8) or 
                		Transitioning to intended state (64)."
::= { prtChannelEntry 8 }
               
               
prtinterpreterlangfamily OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePlangPCL(3),
		   ePlangPJL(5),
		   ePlangPS(6),
		   ePlangAutomatic(37)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The family name of a Page Description Language (PDL) or
        control language which this interpreter in the printer can
		interpret or emulate. 
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Replaces PCL-NAME and FW-ROM-DATECODE ( sort of).  
                Also provides a place to supply PJL information and
                overall ROM information ( by using the language
                switcher as a separate language)."
::= { prtInterpreterEntry 2 }
               
               
prtinterpreterlanglevel OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..31))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The level of the language which this interpreter is
        interpreting or emulating.  This might contain a value like
        '5e' for an interpreter which is emulating level 5e of the PCL
        language.  It might contain '2' for an interpreter which is
        emulating level 2 of the PostScript language.  Similarly it
        might contain '2' for an interpreter which is emulating level
        2 of the HPGL language.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtInterpreterEntry 3 }
               
               
prtinterpreterlangversion OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..31))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The date code or version of the language which this interpreter
        is interpreting or emulating.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                This is a date code determined by the firmware build
                			engineer. The value of these objects will change from
                			build to build and the final value will be determined
                			at some later date. At that time the default values 
                			will be changed to reflect the final value."
::= { prtInterpreterEntry 4 }
               
               
prtinterpreterdescription OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..255))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "A string to identify this interpreter in the localization
        specified by prtGeneralCurrentLocalization as opposed to the
        language which is being interpreted.  It is anticipated that
        this string will allow manufacturers to unambiguously identify
        their interpreters.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                None of these strings are localized."
::= { prtInterpreterEntry 5 }
               
               
prtinterpreterversion OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..31))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The date code, version number, or other product specific
        information tied to this interpreter.  This value is
        associated with the interpreter, rather than with the version
        of the language which is being interpreted or emulated.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Same as prtInterpreterLangVersion."
::= { prtInterpreterEntry 6 }
               
               
prtinterpreterdefaultorientation OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePportrait(3),
		   ePlandscape(4)
		   }
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "The current orientation default for this interpreter.  This
        value may be overridden for a particular job (e.g., by a
        command in the input data stream).
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                Replaces PML DEFAULT-ORIENTATION.  
                Setting this object for one interpreter will change it 
                for all installed interpreters.  
                The automatic language switching and PJL interpreters 
                			ignore the value of this object.   
                			The value for PCL is either ePportrait or ePlandscape;
                			attempting to set it to a different value will cause
                			<badValue> to be returned."
::= { prtInterpreterEntry 7 }
               
               
prtinterpreterfeedaddressability OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The maximum interpreter addressability in the feed
        direction in 10000 prtMarkerAddressabilityUnits (see
        prtMarkerAddressabilityFeedDir ) for this interpreter.
        The value (-1) means other and specifically indicates
        that the sub-unit places no restrictions on this parameter.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtInterpreterEntry 8 }
               
               
prtinterpreterxfeedaddressability OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The maximum interpreter addressability in the cross feed
        direction in 10000 prtMarkerAddressabilityUnits (see
        prtMarkerAddressabilityXFeedDir) for this interpreter.
        The value (-1) means other and specifically indicates
        that the sub-unit places no restrictions on this
        parameter.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtInterpreterEntry 9 }
               
               
prtinterpreterdefaultcharsetin OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePcsISOLatin2(5),
		   ePcsISOLatinCyrillic(8),
		   ePcsISOLatin5(12),
		   ePcsHalfWidthKatakana(15),
		   ePcsHPRoman8(2004)
		   }
    ACCESS  read-write
    STATUS  optional
    DESCRIPTION
                "The default coded character set for input octets
        encountered outside a context in which the Page
        Description Language established the interpretation
        of the octets. (Input octets are presented to the
        interpreter through a path defined in the channel group.)
        This value shall be (2) if there is no default.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                This object refers to PCL symbol set."
::= { prtInterpreterEntry 10 }
               
               
prtinterpreterdefaultcharsetout OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePcsNoDefault(2),
		   ePcsASCII(3),
		   ePcsHPRoman8(2004),
		   ePcsAdobeStandardEncoding(2005)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The default character set for data coming from this interpreter
        through the printer's output channel (i.e. the 'backchannel'). 
        This value shall be (2) if there is no default.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                "
::= { prtInterpreterEntry 11 }
               
               
prtinterpretertwoway OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePyes(3),
		   ePno(4)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "Indicates whether or not this interpreter returns information
        back to the host.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtInterpreterEntry 12 }
               
               
prtconsoledisplaybuffertext OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..255))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The content of a line in the logical display buffer of
        the operator's console of the printer.  When a write
        operation occurs, normally a critical message, to one of
        the LineText strings, the agent should make that line
        displayable if a physical display is present.  Writing
        a zero length string clears the line.  It is an
        implementation-specific matter as to whether the agent allows
        a line to be overwritten before it has been cleared.
        Printer generated strings shall be in the localization
        specified by prtConsoleLocalization.  Management Application
        generated strings should be localized by the Management
        Application.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                 Replaces PML STATUS-MSG-LINE1-PART1 and 
                			STATUS-MSG-LINE2-PART1.  
                			The ojbects BACKGROUND-STATUS-MSG-LINE1-PART1
                			and BACKGROUND-STATUS-MSG-LINE2-PART1 should be used
                			to write messages to the control panel display.  
                			prtConsoleDisplayBufferText[1..8] maps to logical line
                			[1..8] of the display.  
                			Unused lines on the control pannel should retrun NULL."
::= { prtConsoleDisplayBufferEntry 2 }
               
               
prtconsoleontime OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "This object, in conjunction with prtConsoleOffTime, defines
        the current status of the light.  If both prtConsoleOnTime and
        prtConsoleOffTime are non-zero, the lamp is blinking and the
        values presented define the on time and off time, respectively,
        in milliseconds.  If prtConsoleOnTime is zero and 
        prtConsoleOffTime is non-zero, the lamp is off.  If 
        prtConsoleOffTime is zero and prtConsoleOnTime is non-zero, 
        the lamp is on.  If both values are zero the status of the
        lamp is undefined.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                There are three control panel LED's: Ready ( index 1), 
                			Data ( index 2) and Attention ( index 3).   
                			The Ready and Data led flash at the rate of 500 
                			milliseconds on followed by 500 milliseconds off.  
                			The Attention led flashes at the rate of 250 
                			milliseconds on followed by 250 milliseconds off."
                			
::= { prtConsoleLightEntry 2 }
               
               
prtconsoleofftime OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "This object, in conjunction with prtConsoleOnTime, defines
        the current status of the light.  If both prtConsoleOnTime and
        prtConsoleOffTime are non-zero, the lamp is blinking and the
        values presented define the on time and off time, respectively,
        in milliseconds.  If prtConsoleOnTime is zero and 
        prtConsoleOffTime is non-zero, the lamp is off.  If 
        prtConsoleOffTime is zero and prtConsoleOnTime is non-zero, 
        the lamp is on.  If both values are zero the status of the
        lamp is undefined.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                There are three control panel LED's: Ready( index 1), 
                		Data ( index 2) and Attention ( index 3). 
                		The Ready and Data led flash at the rate of 500
                		milliseconds on followed by 500 milliseconds off.  
                		The Attention led flashes at the rate of 250
                		milliseconds on followed by 250 milliseconds off."
                		
::= { prtConsoleLightEntry 3 }
               
               
prtconsolecolor OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePother(1),
		   ePunknown(2),
		   ePwhite(3),
		   ePred(4),
		   ePgreen(5),
		   ePblue(6),
		   ePcyan(7),
		   ePmagenta(8),
		   ePyellow(9),
		   ePorange(10)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The color of this light.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtConsoleLightEntry 4 }
               
               
prtconsoledescription OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..255))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The vendor description or label of this light in the
        localization specified by prtConsoleLocalization.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB."
::= { prtConsoleLightEntry 5 }
               
               
prtalertseveritylevel OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePother(1),
		   ePcriticalBinaryChangeEvent(3),
		   ePwarningUnaryChangeEvent(4),
		   ePwarningBinaryChangeEvent(5)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The level of severity of this alert table entry.  The printer
        determines the severity level assigned to each entry into the
        table.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                The alert table in Color LaserJet8550 will hold up to 233 entries."
::= { prtAlertEntry 2 }
               
               
prtalerttraininglevel OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePother(1),
		   ePuntrained(3),
		   ePtrained(4),
		   ePfieldService(5),
		   ePmanagement(6)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "See textual convention PrtAlertTrainingLevelTC
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                The alert table in Color LaserJet8550 will hold up to 233 entries.
                		The value of this object depends on the alert condition
                			as follows:   
                	ePuntrained: Paper out.  
                	ePtrained: Toner out.  
                	ePfieldService: Marker failure.  
                	ePmanagement: Configuration change."
::= { prtAlertEntry 3 }
               
               
prtalertgroup OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePother(1),
		   ePhostResourcesMIBStorageTable(3),
		   ePhostResourcesMIBDeviceTable(4),
		   ePgeneralPrinter(5),
		   ePcover(6),
		   ePlocalization(7),
		   ePinput(8),
		   ePoutput(9),
		   ePmarker(10),
		   ePmarkerSupplies(11),
		   ePmarkerColorant(12),
		   ePmediaPath(13),
		   ePchannel(14),
		   ePinterpreter(15),
		   ePconsoleDisplayBuffer(16),
		   ePconsoleLights(17)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The type of sub-unit within the printer model that this alert
        is related.  Input, output, and markers are examples of
        printer model groups, i.e., examples of types of sub-units.
        Wherever possible, these enumerations match the
        sub-identifier that identifies the relevant table in the
        printmib.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                The alert table in Color LaserJet8550 will hold up to 233 entries."
::= { prtAlertEntry 4 }
               
               
prtalertgroupindex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "An index of the row within the principle table in the
        group identified by prtAlertGroup that represents the
        sub-unit of the printer that caused this alert.  The
        combination of the prtAlertGroup and the prtAlertGroupIndex defines
        exactly which printer sub-unit caused the alert.; for
        example, Input #3, Output #2, and Marker #1.
        Every object in this MIB is indexed with hrDeviceIndex and
        optionally, another index variable.  If this other index
        variable is present in the table that generated the alert, it
        will be used as the value for this object.  Otherwise, this
        value shall be -1.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                The alert table in Color LaserJet8550 will hold up to 233 entries."
::= { prtAlertEntry 5 }
               
               
prtalertlocation OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "The sub-unit location that is defined by the printer
        manufacturer to further refine the location of this alert
        within the designated sub-unit.  The location is used in
        conjunction with the Group and GroupIndex values; for
        example, there is an alert in Input #2 at location number 7.
	 The value (-2) indicates unknown
	 Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                The alert table in Color LaserJet8550 will hold up to 233 entries."
::= { prtAlertEntry 6 }
               
               
prtalertcode OBJECT-TYPE
    SYNTAX  INTEGER {
		   ePother(1),
		   ePunknown(2),
		   ePcoverOpened(3),
		   ePcoverClosed(4),
		   ePinterlockOpened(5),
		   ePinterlockClosed(6),
		   ePconfigurationChanged(7),
		   ePjammed(8),
		   ePsubunitMissing(9),
		   ePsubunitLifeAlmostOver(10),
		   ePsubunitLifeOver(11),
		   ePsubunitAlmostEmpty(12),
		   ePsubunitEmpty(13),
		   ePsubunitAlmostFull(14),
		   ePsubunitFull(15),
		   ePsubunitNearLimit(16),
		   ePsubunitAtLimit(17),
		   ePsubunitOpened(18),
		   ePsubunitClosed(19),
		   ePsubunitTurnedOn(20),
		   ePsubunitTurnedOff(21),
		   ePsubunitOffline(22),
		   ePsubunitPowerSaver(23),
		   ePsubunitWarmingUp(24),
		   ePsubunitAdded(25),
		   ePsubunitRemoved(26),
		   ePsubunitRecousrceAdded(27),
		   ePsubunitResourceRemoved(28),
		   ePsubunitRecoverableFailure(29),
		   ePsubunitUnrecoverableFailure(30),
		   ePsubunitRecoverableStorageError(31),
		   ePsubunitUnrecoverableStorageError(32),
		   ePsubunitMotorFailure(33),
		   ePsubunitMemoryExhausted(34),
		   ePcoverOpened(501),
		   ePcoverClosed(502),
		   ePpoweredUp(503),
		   ePpoweredDown(504),
		   ePprinterNMSReset(505),
		   ePprinterManualReset(506),
		   ePprinterReadyToPrint(507),
		   ePinputMediaTrayMissing(801),
		   ePinputMediaSizeChanged(802),
		   ePinputMediaWeightChanged(803),
		   ePinputMediaTypeChanged(804),
		   ePinputMediaColorChanged(805),
		   ePinputMediaFormPartsChange(806),
		   ePinputMediaSupplyLow(807),
		   ePinputMediaSupplyEmpty(808),
		   ePinputMediaChangeRequest(809),
		   ePinputManualInputRequest(810),
		   ePinputTrayPositionFailure(811),
		   ePinputTrayElevationFailure(812),
		   ePinputCannotFeedSizeSelected(813),
		   ePoutputMediaTrayMissing(901),
		   ePoutputMediaTrayAlmostFull(902),
		   ePoutputMediaTrayFull(903),
		   ePoutputMailboxSelectFailure(904),
		   ePmarkerFuserUnderTemperature(1001),
		   ePmarkerFuserOverTemperature(1002),
		   ePmarkerFuserTimingFailure(1003),
		   ePmarkerFuserThermistorFailure(1004),
		   ePmarkerAdjustingPrintQuality(1005),
		   ePmarkerTonerEmpty(1101),
		   ePmarkerInkEmpty(1102),
		   ePmarkerPrintRibbonEmpty(1103),
		   ePmarkerTonerAlmostEmpty(1104),
		   ePmarkerInkAlmostEmpty(1105),
		   ePmarkerPrintRibbonAlmostEmpty(1106),
		   ePmarkerWasteTonerReceptacleAlmostFull(1107),
		   ePmarkerWasteInkReceptacleAlmostFull(1108),
		   ePmarkerWasteTonerReceptacleFull(1109),
		   ePmarkerWasteInkReceptacleFull(1110),
		   ePmarkerOpcLifeAlmostOver(1111),
		   ePmarkerOpcLifeOver(1112),
		   ePmarkerDeveloperAlmostEmpty(1113),
		   ePmarkerDeveloperEmpty(1114),
		   ePmarkerTonerCartridgeMissing(1115),
		   ePmediaPathMediaTrayMissing(1301),
		   ePmediaPathMediaTrayAlmostFull(1302),
		   ePmediaPathMediaTrayFull(1303),
		   ePinterpreterMemoryIncreased(1501),
		   ePinterpreterMemoryDecreased(1502),
		   ePinterpreterCartridgeAdded(1503),
		   ePinterpreterCartridgeDeleted(1504),
		   ePinterpreterResourceAdded(1505),
		   ePinterpreterResourceDeleted(1506),
		   ePinterpreterResourceUnavailable(1507),
		   ePinterpreterComplexPageEncountered(1509),
		   ePalertRemovalOfBinaryChangeEntry(1801)
		   }
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "See associated textual convention PrtAlertCodeTC
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                The alert table in Color LaserJet8550 will hold up to 233 entries."
::= { prtAlertEntry 7 }
               
               
prtalertdescription OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..255))
    ACCESS  read-only
    STATUS  optional
    DESCRIPTION
                "A description of this alert entry in the localization
        specified by prtGeneralCurrentLocalization.  The description is
        provided by the printer to further elaborate on the enumerated
        alert or provide information in the case where the code is
        classified as `other' or `unknown'.  The printer is required
        to return a description string but the string may be a null
        string.
	Refer to Printer Management Standards web page, http://www.pwg.org, for more details in the original format of the Standard Printer MIB.
                Additional information:
                The alert table in Color LaserJet8550 will hold up to 233 entries."
::= { prtAlertEntry 8 }
               
               
END