HM2-CAM-MGMT-MIB DEFINITIONS ::= BEGIN

--
-- *************************************************************
-- Hirschmann CAM Management MIB
-- *************************************************************
--

IMPORTS
    MODULE-IDENTITY,
    NOTIFICATION-TYPE, 
    OBJECT-TYPE,
    Integer32           	FROM SNMPv2-SMI -- RFC 2578
    RowStatus,               
    TruthValue				FROM SNMPv2-TC
    InetAddressType, 
    InetAddress,
	InetPortNumber          FROM INET-ADDRESS-MIB -- RFC4001
    SnmpAdminString     	FROM SNMP-FRAMEWORK-MIB
	HmEnabledStatus,
	hm2ConfigurationMibs   	FROM HM2-TC-MIB;

hm2CamMgmtMib MODULE-IDENTITY
	LAST-UPDATED "201307010000Z" -- July 1, 2013
    ORGANIZATION "Hirschmann Automation and Control GmbH"
    CONTACT-INFO
        "Postal:     Stuttgarter Str. 45-51
                     72654 Neckartenzlingen
                     Germany
         Phone:      +49 7127 140
         E-mail:     hac.support@belden.com"
    DESCRIPTION
        "Hirschmann dummy for Central Authentication Management MIB for ABB.
         Copyright (C) 2013. All Rights Reserved."
    REVISION     "201307010000Z" -- July 1, 2013
    DESCRIPTION
         "Initial version."
    ::= { hm2ConfigurationMibs 200 }

--
-- *************************************************************
-- hm2CamMgmtMib
-- *************************************************************
--
hm2CamMgmtMibNotifications			OBJECT IDENTIFIER ::= { hm2CamMgmtMib 0 }
hm2CamMgmtMibObjects				OBJECT IDENTIFIER ::= { hm2CamMgmtMib 1 }
-- hm2CamMgmtMibConformance			OBJECT IDENTIFIER ::= { hm2CamMgmtMib 2 }

--
-- *************************************************************
-- hm2CamMgmtMib groups
-- *************************************************************
--
hm2CamConfigGroup 					OBJECT IDENTIFIER ::= { hm2CamMgmtMibObjects 1 }
hm2CamActionGroup					OBJECT IDENTIFIER ::= { hm2CamMgmtMibObjects 10 }
hm2CamPwdChangeGroup				OBJECT IDENTIFIER ::= { hm2CamMgmtMibObjects 20 }
hm2CamCertInfoGroup					OBJECT IDENTIFIER ::= { hm2CamMgmtMibObjects 30 }

--
-- *************************************************************
-- hm2CamConfigGroup
-- *************************************************************
--
	
hm2CamConfigAdminStatus OBJECT-TYPE
    SYNTAX		HmEnabledStatus
	MAX-ACCESS	read-write
	STATUS		current
	DESCRIPTION
				"Configure authentication via CAM server.
				 If CAM authentication is enabled local users are deactivated.
				 Authentication will be done via CAM server (primary or backup) or
				 replicated user database on switch. Otherwise access to the switch
				 is not possible."
	DEFVAL		{ disable }                   
     ::= { hm2CamConfigGroup 1 }
	 
hm2CamConfigLastValidServerindex OBJECT-TYPE
    SYNTAX		Integer32 (1..2)
	MAX-ACCESS	read-write
	STATUS		current
	DESCRIPTION
				"Last valid CAM server with succesful connection and authentication.
				 Note: this attribute is set by CAM management application."                 
     ::= { hm2CamConfigGroup 2 }

hm2CamClientServerAddrTable OBJECT-TYPE
	SYNTAX SEQUENCE OF Hm2CamClientServerAddrEntry
	MAX-ACCESS 		not-accessible
	STATUS 			current
	DESCRIPTION
		"This table contains objects to configure
		 CAM client connections."
	::= { hm2CamConfigGroup 10 }

hm2CamClientServerAddrEntry OBJECT-TYPE
   SYNTAX 		Hm2CamClientServerAddrEntry
   MAX-ACCESS 	not-accessible
   STATUS 		current
   DESCRIPTION 
		"The CAM client connection objects."
   INDEX { hm2CamClientServerIndex }
   ::= { hm2CamClientServerAddrTable 1 }

Hm2CamClientServerAddrEntry ::= SEQUENCE {
   hm2CamClientServerIndex 					Integer32,
   hm2CamClientServerAddrType 				InetAddressType,
   hm2CamClientServerAddr 					InetAddress,
   hm2CamClientServerPort	 				InetPortNumber,
   hm2CamClientServerDescr	 				SnmpAdminString,
   hm2CamClientServerBaseDN					SnmpAdminString,
   hm2CamClientServerSearchString			SnmpAdminString,
   hm2CamClientServerStatus 				INTEGER,
   hm2CamClientServerReplicationInterval	Integer32,
   hm2CamClientServerReplicationStatus		INTEGER,
   hm2CamClientServerRowStatus				RowStatus
   }		 

hm2CamClientServerIndex OBJECT-TYPE
    SYNTAX		Integer32 (1..2)
	MAX-ACCESS	accessible-for-notify
	STATUS		current
	DESCRIPTION
				"Index for CAM server table."
     ::= { hm2CamClientServerAddrEntry 1 }

hm2CamClientServerAddrType OBJECT-TYPE
    SYNTAX		InetAddressType
	MAX-ACCESS	read-create
	STATUS		current
	DESCRIPTION
				"Address type."
	DEFVAL		{ ipv4 }                   
     ::= { hm2CamClientServerAddrEntry 2 }
         
hm2CamClientServerAddr OBJECT-TYPE
    SYNTAX		InetAddress
	MAX-ACCESS	read-create
	STATUS		current
	DESCRIPTION
				"IP address of CAM authentication server."
	DEFVAL		{ '00000000'H }                   
     ::= { hm2CamClientServerAddrEntry 3 }

hm2CamClientServerPort OBJECT-TYPE
    SYNTAX		InetPortNumber
	MAX-ACCESS	read-create
	STATUS		current
	DESCRIPTION
				"The port number of the CAM authentication server."
	DEFVAL		{ 389 }                   
     ::= { hm2CamClientServerAddrEntry 4 }

hm2CamClientServerDescr  OBJECT-TYPE
   SYNTAX 		SnmpAdminString (SIZE(0..100))
   MAX-ACCESS 	read-create
   STATUS 		current
   DESCRIPTION
   	   "The description of the server configured."
   ::= { hm2CamClientServerAddrEntry 5 }

hm2CamClientServerBaseDN  OBJECT-TYPE
   SYNTAX 		SnmpAdminString (SIZE(0..100))
   MAX-ACCESS 	read-create
   STATUS 		current
   DESCRIPTION
   	   "Base distinguished name for LDAP query to CAM server."
   ::= { hm2CamClientServerAddrEntry 6 }

hm2CamClientServerSearchString  OBJECT-TYPE
   SYNTAX 		SnmpAdminString (SIZE(0..100))
   MAX-ACCESS 	read-create
   STATUS 		current
   DESCRIPTION
   	   "Search string for LDAP query to CAM server."
   ::= { hm2CamClientServerAddrEntry 7 }   
 
 hm2CamClientServerStatus OBJECT-TYPE
     SYNTAX      INTEGER {
				 ok(1),
				 unreachable(2),
				 other(3)
				 }
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
                 "Status of authentication against CAM server:
                  - ok			-> CAM server reachable, authentication succeeded
				  - unreachable -> CAM server (primary and backup) not reachable
				  - other       -> any other error state"
	 DEFVAL  { other }					    
     ::= { hm2CamClientServerAddrEntry 8 }
		
hm2CamClientServerReplicationInterval OBJECT-TYPE
     SYNTAX      Integer32 (10..1440)
	 UNITS		 "minutes"
     MAX-ACCESS  read-create
     STATUS      current
     DESCRIPTION
                 "Configurable replication interval in minutes."
     DEFVAL  { 60 }
     ::= { hm2CamClientServerAddrEntry 9 }
     
hm2CamClientServerReplicationStatus OBJECT-TYPE
     SYNTAX      INTEGER {
				 ok(1),
				 unsuccessful(2),
				 other(3)
				 }
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
                 "Status of CAM replication:
                  - ok			 -> CAM server reachable, replication succeeded
				  - unsuccessful -> Replication was not successful
				  - other        -> any other error state"
	 DEFVAL  { other }					    
     ::= { hm2CamClientServerAddrEntry 10 } 
		 
hm2CamClientServerRowStatus OBJECT-TYPE
	SYNTAX      RowStatus
	MAX-ACCESS  read-create
	STATUS      current
	DESCRIPTION
		"Indicates the status of an entry in this table,
		and is used to create/delete entries. Objects
		within this table can by changed while the status
		is 'active'."
	::= { hm2CamClientServerAddrEntry 11 }


--
-- *************************************************************
-- hm2CamActionGroup
-- *************************************************************
--
hm2CamAction OBJECT-TYPE
    SYNTAX      INTEGER {
				 other(1),
				 testConnection(2),
				 doReplication(3)
				 }
	MAX-ACCESS	read-write
	STATUS		current
	DESCRIPTION
				"Test available CAM server connections. Status of testing the CAM
				server connections is shown in abb2CamTestConnectionStatus."      
	DEFVAL  { other }   
     ::= { hm2CamActionGroup 1 }
  
hm2CamActionConnectionStatus OBJECT-TYPE
    SYNTAX      INTEGER {
				 ok(1),
				 unreachable(2),
				 pending(3),
				 other(4)
				 }
	MAX-ACCESS	read-only
	STATUS		current
	DESCRIPTION
				"Status of available CAM server connections.
					- ok(1) 		-> at least one CAM server reachable.
					- unreachable(2)-> no CAM server reachable.
					- pending(3)    -> testing connections is in progress.
					- other(4)		-> no test has been done."   
     ::= { hm2CamActionGroup 2 }

hm2CamActionReplicationStatus OBJECT-TYPE
    SYNTAX      INTEGER {
				 ok(1),
				 unsuccessful(2),
				 pending(3),
				 other(4)
				 }
	MAX-ACCESS	read-only
	STATUS		current
	DESCRIPTION
				"Status of replication to an available CAM server.
					- ok(1) 		 -> replication successful.
					- unsuccessful(2)-> replication unsuccessful.
					- pending(3)     -> replication is in progress.
					- other(4)		 -> no replication has been done."   
     ::= { hm2CamActionGroup 3 }

--
-- *************************************************************
-- hm2CamPwdChangeGroup
-- *************************************************************
--
	
hm2CamPwdChangeUserName OBJECT-TYPE
    SYNTAX 		SnmpAdminString (SIZE(0..100))
	MAX-ACCESS	read-write
	STATUS		current
	DESCRIPTION
				"Set user name of user whose password has to be changed on CAM server."         
     ::= { hm2CamPwdChangeGroup 1 }
	 
hm2CamPwdChangeUserPwOld OBJECT-TYPE
    SYNTAX 		SnmpAdminString (SIZE(0..100))
	MAX-ACCESS	read-write
	STATUS		current
	DESCRIPTION
				"Set old password of user whose password has to be changed on CAM server."         
     ::= { hm2CamPwdChangeGroup 2 }
     
hm2CamPwdChangeUserPwNew OBJECT-TYPE
    SYNTAX 		SnmpAdminString (SIZE(0..100))
	MAX-ACCESS	read-write
	STATUS		current
	DESCRIPTION
				"Set new password of user whose password has to be changed on CAM server."         
     ::= { hm2CamPwdChangeGroup 3 }
     
hm2CamPwdChangeAction OBJECT-TYPE
     SYNTAX      INTEGER {
				 other(1),
				 changePwd(2)
				 }
     MAX-ACCESS  read-write
     STATUS      current
     DESCRIPTION
                 "Execute password change of given user on CAM server.
                  - other       -> no action, password is not changed on CAM server
                  - changePwd	-> change password"
	 DEFVAL  { other }					    
     ::= { hm2CamPwdChangeGroup 4 } 


hm2CamPwdChangeActionStatus OBJECT-TYPE
     SYNTAX      INTEGER {
				 ok(1),
				 unsuccessful(2),
				 pending(3),
				 other(4)
				 }
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
				"Status of password change action on available CAM server.
					- ok(1) 		 -> password change successful.
					- unsuccessful(2)-> password change unsuccessful.
					- pending(3)     -> password change is in progress.
					- other(4)		 -> password change was never done."
     ::= { hm2CamPwdChangeGroup 5 }
     
--
-- *************************************************************
-- hm2CamCertInfoTable
-- *************************************************************
--
hm2CamCertInfoTable OBJECT-TYPE
	SYNTAX SEQUENCE OF Hm2CamCertInfoEntry
	MAX-ACCESS 		not-accessible
	STATUS 			current
	DESCRIPTION
		"This table ...."
	::= { hm2CamCertInfoGroup 1 }

hm2CamCertInfoEntry OBJECT-TYPE
   SYNTAX 		Hm2CamCertInfoEntry
   MAX-ACCESS 	not-accessible
   STATUS 		current
   DESCRIPTION 
		"The CAM ..."
   INDEX { hm2CamCertInfoIndex }
   ::= { hm2CamCertInfoTable 1 }

Hm2CamCertInfoEntry ::= SEQUENCE {
   hm2CamCertInfoIndex 			INTEGER,
   hm2CamCertInfoPresent		TruthValue,
   hm2CamCertInfoExpiry			SnmpAdminString,   
   hm2CamCertInfoIssuer			SnmpAdminString,
   hm2CamCertInfoSubject		SnmpAdminString,
   hm2CamCertInfoSerialNumber	SnmpAdminString
   }		 

hm2CamCertInfoIndex OBJECT-TYPE
    SYNTAX		INTEGER {
    					  rootCert(1),
    					  deviceCert(2)
    					}
	MAX-ACCESS	not-accessible
	STATUS		current
	DESCRIPTION
				"Index for CAM certificate table."
     ::= { hm2CamCertInfoEntry 1 }
	
hm2CamCertInfoPresent OBJECT-TYPE
    SYNTAX		TruthValue
	MAX-ACCESS	read-only
	STATUS		current
	DESCRIPTION
				"Certificate present on device."
     ::= { hm2CamCertInfoEntry 2 }	
	
hm2CamCertInfoExpiry OBJECT-TYPE
    SYNTAX		SnmpAdminString
	MAX-ACCESS	read-only
	STATUS		current
	DESCRIPTION
				"Expiry information of certificate."
     ::= { hm2CamCertInfoEntry 3 }
  
hm2CamCertInfoIssuer OBJECT-TYPE
    SYNTAX		SnmpAdminString
	MAX-ACCESS	read-only
	STATUS		current
	DESCRIPTION
				"Issuer information of certificate."
     ::= { hm2CamCertInfoEntry 4 }

hm2CamCertInfoSubject OBJECT-TYPE
    SYNTAX		SnmpAdminString
	MAX-ACCESS	read-only
	STATUS		current
	DESCRIPTION
				"Subject information of certificate."
     ::= { hm2CamCertInfoEntry 5 }
  
hm2CamCertInfoSerialNumber OBJECT-TYPE
    SYNTAX		SnmpAdminString
	MAX-ACCESS	read-only
	STATUS		current
	DESCRIPTION
				"Serial number of certificate."
     ::= { hm2CamCertInfoEntry 6 }

-- 
-- ***********************************************************
-- hm2CamMgmtMibNotifications
-- ***********************************************************
--
hm2CamConfigStatusTrap  NOTIFICATION-TYPE
	OBJECTS		{ hm2CamClientServerIndex, hm2CamClientServerStatus }
	STATUS		current
	DESCRIPTION 
				"This notification is send when authentication via CAM server is done."
	::= { hm2CamMgmtMibNotifications 1 }
	
hm2CamReplicationStatusTrap  NOTIFICATION-TYPE
	OBJECTS		{ hm2CamClientServerIndex, hm2CamClientServerReplicationStatus }
	STATUS		current
	DESCRIPTION 
				"This notification is send when replication via CAM server is done."
	::= { hm2CamMgmtMibNotifications 2 }
	
END