FORTINET-FORTIANALYZER-MIB DEFINITIONS ::= BEGIN

IMPORTS
    FnIndex, fnGenTrapMsg, fnSysSerial, fortinet, fnTrapsPrefix
        FROM FORTINET-CORE-MIB
    InetPortNumber
        FROM INET-ADDRESS-MIB
    sysName
        FROM SNMPv2-MIB
    MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
        FROM SNMPv2-CONF
    Counter32, Gauge32, Integer32, IpAddress, MODULE-IDENTITY,
    NOTIFICATION-TYPE, OBJECT-TYPE
        FROM SNMPv2-SMI
    DisplayString, TEXTUAL-CONVENTION
        FROM SNMPv2-TC;

fnFortiAnalyzerMib MODULE-IDENTITY
    LAST-UPDATED "200909210000Z"
    ORGANIZATION 
        "Fortinet Technologies, Inc."
    CONTACT-INFO 
        "
         Technical Support
         email: support@fortinet.com
         http://www.fortinet.com"
    DESCRIPTION 
        "MIB module for Fortinet FortiAnalyzer devices."
    REVISION    "200909210000Z"
    DESCRIPTION 
        "Fix syntax errors."
    REVISION    "200902050000Z"
    DESCRIPTION 
        "Initial version of FORTINET-FORTIANALYZER-MIB."
    ::= { fortinet 102 }

FaSessProto ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "data type for session protocols"
    SYNTAX      INTEGER { ip(0), icmp(1), igmp(2), ipip(4), tcp(6),
                    egp(8), pup(12), udp(17), idp(22), ipv6(41),
                    rsvp(46), gre(47), esp(50), ah(51), ospf(89),
                    pim(103), comp(108), raw(255) }

FaRAIDStatusCode ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION 
        "Enumerated list of RAID status codes."
    SYNTAX      INTEGER { arrayOK(1), arrayDegraded(2), arrayInoperable(3),
		    arrayRebuilding(4), arrayRebuildingStarted(5),
		    arrayRebuildingFinished(6), arrayInitializing(7),
                    arrayInitializingStarted(8), arrayInitializingFinished(9),
                    diskOK(10), diskDegraded(11), diskFailEvent(12) }

FaSysEventCode ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION 
        "Enumerated list of system events."
    SYNTAX      INTEGER { systemHalt(1), systemReboot(2), 
                    upgradeConfig(3), systemUpgrade(4), logdiskFormat(5) }

faTraps OBJECT IDENTIFIER
    ::= { fnFortiAnalyzerMib 0 }

faTrapPrefix OBJECT IDENTIFIER
    ::= { faTraps 0 }

faTrapObject OBJECT IDENTIFIER
    ::= { faTraps 1 }

faSystemEvent OBJECT-TYPE
    SYNTAX      FaSysEventCode
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION 
        "Type of system event that triggered notification."
    ::= { faTrapObject 1 }

faRAIDStatus OBJECT-TYPE
    SYNTAX      FaRAIDStatusCode
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION 
        "New RAID state associated with a RAID status change event."
    ::= { faTrapObject 2 }

faRAIDDevIndex OBJECT-TYPE
    SYNTAX      DisplayString (SIZE(0..32))
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION 
        "Name/index of a RAID device relating to the event."
    ::= { faTrapObject 3 }

faGenAlert OBJECT-TYPE
    SYNTAX          DisplayString 
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION     
        "Detail of defined event alert sent from FortiAnalyzer"
    ::= { faTrapObject  4 }

faModel OBJECT IDENTIFIER
    ::= { fnFortiAnalyzerMib 1 }

faz100 OBJECT IDENTIFIER
    ::= { faModel 1000 }

faz100A OBJECT IDENTIFIER
    ::= { faModel 1001 }

faz100B OBJECT IDENTIFIER
    ::= { faModel 1002 }

faz100C OBJECT IDENTIFIER
    ::= { faModel 1003 }

faz400 OBJECT IDENTIFIER
    ::= { faModel 4000 }

faz400B OBJECT IDENTIFIER
    ::= { faModel 4002 }

faz800 OBJECT IDENTIFIER
    ::= { faModel 8000 }

faz800B OBJECT IDENTIFIER
    ::= { faModel 8002 }

faz1000B OBJECT IDENTIFIER
    ::= { faModel 10002 }

faz2000 OBJECT IDENTIFIER
    ::= { faModel 20000 }

faz2000A OBJECT IDENTIFIER
    ::= { faModel 20001 }

faz4000 OBJECT IDENTIFIER
    ::= { faModel 40000 }

faz4000A OBJECT IDENTIFIER
    ::= { faModel 40001 }


faInetProto OBJECT IDENTIFIER
    ::= { fnFortiAnalyzerMib 2 }

faInetProtoInfo OBJECT IDENTIFIER
    ::= { faInetProto 1 }

faInetProtoTables OBJECT IDENTIFIER
    ::= { faInetProto 2 }

faIpSessTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF FaIpSessEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION 
        "Information on the IP sessions active on the device"
    ::= { faInetProtoTables 1 }

faIpSessEntry OBJECT-TYPE
    SYNTAX      FaIpSessEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION 
        "Information on a specific session, including source and destination"
    INDEX       { faIpSessIndex }
    ::= { faIpSessTable 1 }

FaIpSessEntry ::= SEQUENCE {
    faIpSessIndex       FnIndex,
    faIpSessProto       FaSessProto,
    faIpSessFromAddr    IpAddress,
    faIpSessFromPort    InetPortNumber,
    faIpSessToAddr      IpAddress,
    faIpSessToPort      InetPortNumber,
    faIpSessExp         Counter32
}

faIpSessIndex OBJECT-TYPE
    SYNTAX      FnIndex
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION 
        "An index value that uniquely identifies
         an IP session within the faIpSessTable"
    ::= { faIpSessEntry 1 }

faIpSessProto OBJECT-TYPE
    SYNTAX      FaSessProto
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "The protocol the session is using (IP, TCP, UDP, etc.)"
    ::= { faIpSessEntry 2 }

faIpSessFromAddr OBJECT-TYPE
    SYNTAX      IpAddress
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Source IP address (IPv4 only) of the session"
    ::= { faIpSessEntry 3 }

faIpSessFromPort OBJECT-TYPE
    SYNTAX      InetPortNumber
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Source port number (UDP and TCP only) of the session"
    ::= { faIpSessEntry 4 }

faIpSessToAddr OBJECT-TYPE
    SYNTAX      IpAddress
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Destination IP address (IPv4 only) of the session"
    ::= { faIpSessEntry 5 }

faIpSessToPort OBJECT-TYPE
    SYNTAX      InetPortNumber
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Destination Port number (UDP and TCP only) of the session"
    ::= { faIpSessEntry 6 }

faIpSessExp OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Number of seconds remaining before the session expires (if idle)"
    ::= { faIpSessEntry 7 }

fa300Compat OBJECT IDENTIFIER
    ::= { fnFortiAnalyzerMib 99 }

faHwSensors OBJECT IDENTIFIER
    ::= { fa300Compat 1 }

faHwSensorCount OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      deprecated
    DESCRIPTION 
        "The number of entries in faHwSensorTable"
    ::= { faHwSensors 1 }

faHwSensorTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF FaHwSensorEntry
    MAX-ACCESS  not-accessible
    STATUS      deprecated
    DESCRIPTION 
        "A list of device specific hardware sensors and values. Because different devices have different hardware sensor capabilities, this table may or may not contain any values."
    ::= { faHwSensors 2 }

faHwSensorEntry OBJECT-TYPE
    SYNTAX      FaHwSensorEntry
    MAX-ACCESS  not-accessible
    STATUS      deprecated
    DESCRIPTION 
        "An entry containing the name, value, and alarm status of a given hardware sensor"
    INDEX       { faHwSensorEntIndex }
    ::= { faHwSensorTable 1 }

FaHwSensorEntry ::= SEQUENCE {
    faHwSensorEntIndex          FnIndex,
    faHwSensorEntName           DisplayString,
    faHwSensorEntValue          DisplayString,
    faHwSensorEntAlarmStatus    INTEGER
}

faHwSensorEntIndex OBJECT-TYPE
    SYNTAX      FnIndex
    MAX-ACCESS  not-accessible
    STATUS      deprecated
    DESCRIPTION 
        "A unique identifier within the faHwSensorTable"
    ::= { faHwSensorEntry 1 }

faHwSensorEntName OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      deprecated
    DESCRIPTION 
        "A string identifying the sensor by name"
    ::= { faHwSensorEntry 2 }

faHwSensorEntValue OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      deprecated
    DESCRIPTION 
        "A string representation of the value of the sensor. Because sensors can present data in different formats, string representation is most general format. Interpretation of the value (units of measure, for example) is dependent on the individual sensor."
    ::= { faHwSensorEntry 3 }

faHwSensorEntAlarmStatus OBJECT-TYPE
    SYNTAX      INTEGER { false(0), true(1) }
    MAX-ACCESS  read-only
    STATUS      deprecated
    DESCRIPTION 
        "If the sensor has an alarm threshold and has exceeded it, this will indicate its status. Not all sensors have alarms."
    ::= { faHwSensorEntry 4 }



fa300System OBJECT IDENTIFIER
    ::= { fa300Compat 2 }

fa300SysSerial OBJECT-TYPE
    SYNTAX      DisplayString (SIZE(0..32))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Serial number of the device"
    ::= { fa300System 1 }

fa300SysVersion OBJECT-TYPE
    SYNTAX      DisplayString (SIZE(0..128))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Firmware version of the device"
    ::= { fa300System 2 }

fa300SysCpuUsage OBJECT-TYPE
    SYNTAX      Gauge32 (0..100)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Current CPU usage (percentage)"
    ::= { fa300System 3 }

fa300SysMemUsage OBJECT-TYPE
    SYNTAX      Gauge32 (0..100)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Current memory utilization (percentage)"
    ::= { fa300System 4 }

fa300SysSesCount OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Number of active sessions on the device"
    ::= { fa300System 5 }

fa300SysDiskCapacity OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Total hard disk capacity (MB), if disk is present"
    ::= { fa300System 6 }

fa300SysDiskUsage OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Current hard disk usage (MB), if disk is present"
    ::= { fa300System 7 }

fa300SysMemCapacity OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
        "Total physical memory (RAM) installed (KB)"
    ::= { fa300System 8 }




faMIBConformance OBJECT IDENTIFIER
    ::= { fnFortiAnalyzerMib 100 }

faTrapSystemEvent NOTIFICATION-TYPE
    OBJECTS     { fnSysSerial, faSystemEvent }
    STATUS      current
    DESCRIPTION 
        "A system event occured. The specific type of event is indecated by the faSystemEvent parameter."
    ::= { faTrapPrefix 1001 }

faTrapRAIDStatusChange NOTIFICATION-TYPE
    OBJECTS     { fnSysSerial, faRAIDStatus, faRAIDDevIndex }
    STATUS      current
    DESCRIPTION 
        "Trap is sent when there is a change in the status of the RAID array, if present."
    ::= { faTrapPrefix 1002 }

faTrapGenAlert NOTIFICATION-TYPE
    OBJECTS     { fnSysSerial, fnGenTrapMsg }
    STATUS      current
    DESCRIPTION 
        "Trap sent when FortiAnalyzer event parameter
         exceeds configured limit. Event description
         included in trap."
    ::= { faTrapPrefix 1003 }


faTrapLogRateThreshold NOTIFICATION-TYPE
    OBJECTS     { fnSysSerial, sysName }
    STATUS      current
    DESCRIPTION
        "Indicates that the incoming log rate has exceeded the configured threshold."
    ::= { fnTrapsPrefix 1005 }

faTrapDataRateThreshold NOTIFICATION-TYPE
    OBJECTS     { fnSysSerial, sysName }
    STATUS      current
    DESCRIPTION
        "Indicates that the incoming data rate has exceeded the configured threshold."
    ::= { fnTrapsPrefix 1006 }



faSystemComplianceGroup OBJECT-GROUP
    OBJECTS {
		fa300SysSerial,
		fa300SysVersion,
		fa300SysCpuUsage,
		fa300SysMemUsage,
		fa300SysDiskCapacity,
		fa300SysDiskUsage,
		fa300SysMemCapacity,
		fa300SysSesCount,
		faSystemEvent
	    }
    STATUS current
    DESCRIPTION "System related instrumentation"
	::= { faMIBConformance 1 }


faTrapsComplianceGroup NOTIFICATION-GROUP
    NOTIFICATIONS { faTrapSystemEvent, faTrapRAIDStatusChange, 
                  faTrapGenAlert, faTrapLogRateThreshold, faTrapDataRateThreshold }
    STATUS      current
    DESCRIPTION 
        "Event notifications"
    ::= { faMIBConformance 2 }


faSessionComplianceGroup OBJECT-GROUP
    OBJECTS {
		faIpSessProto,
		faIpSessFromAddr,
		faIpSessFromPort,
		faIpSessToAddr,
		faIpSessToPort,
		faIpSessExp
	    }
    STATUS current
    DESCRIPTION "Session related instrumentation"
	::= { faMIBConformance 3 }

faMiscComplianceGroup OBJECT-GROUP
	OBJECTS {
			faGenAlert

		}
		STATUS current
		DESCRIPTION "Miscellanious instrumentation"
		::= { faMIBConformance 4 }

faHwSensorComplianceGroup OBJECT-GROUP
	OBJECTS {
		faHwSensorCount,
		faHwSensorEntName,
		faHwSensorEntValue,
		faHwSensorEntAlarmStatus
	}
	STATUS deprecated
	DESCRIPTION "Hardware sensor related information"
		::= { faMIBConformance 5 }

faNotificationObjectsComplianceGroup OBJECT-GROUP
    OBJECTS     { faSystemEvent, faRAIDStatus, faRAIDDevIndex }
    STATUS      current
    DESCRIPTION 
        "Object identifiers used in notifications"
    ::= { faMIBConformance 6 }




faMIBCompliance MODULE-COMPLIANCE
    STATUS      current
    DESCRIPTION 
        "The compliance statement for the application MIB."

    MODULE      -- this module

    GROUP faSystemComplianceGroup
    DESCRIPTION "System related instrumentation"

    GROUP faSessionComplianceGroup
    DESCRIPTION 
	"Session related instrumentation"

    GROUP faMiscComplianceGroup
    DESCRIPTION "Miscellanious instrumentation"

    GROUP   faTrapsComplianceGroup
    DESCRIPTION   
	"Traps are optional. Not all models support all traps. Consult product literature to see which traps are supported."

    GROUP   faNotificationObjectsComplianceGroup
    DESCRIPTION   
    	"Object identifiers used in notifications. Objects are required if their containing trap is implemented."

    ::= { faMIBConformance 100 }



faObsoleteMIBCompliance MODULE-COMPLIANCE
    STATUS      deprecated
    DESCRIPTION 
        "The compliance statement of deprecated objects for the application MIB, they may still be used by older models."

    MODULE      -- this module

        GROUP   faHwSensorComplianceGroup
        DESCRIPTION   
              "Traps are optional. Not all models support all traps. Consult product literature to see which traps are supported."

    ::= { faMIBConformance 101 }


END -- end of module FORTINET-FORTIANALYZER-MIB.