-- The Ericsson Alarm Textual Conventions MIB
--
-- Copyright (c) 2008 by Ericsson AB.
-- All rights reserved.
--
-- This MIB is documented further in EAB/OP-07:0139
--
-- Authors:
-- Stefan Wallin (DataDuctus, primary author)
-- Vincent Desbois
-- Ulf Hallgarn
-- Tomas Jonsson
-- Peter Loborg
-- David Partain
-- Mattias Pettersson A
-- Ingemar Segerberg
-- Johan Wallin
-- Martin Wettergren
--

ERICSSON-ALARM-TC-MIB DEFINITIONS ::= BEGIN

-- Add imports as needed
IMPORTS
        MODULE-IDENTITY, Unsigned32
                FROM SNMPv2-SMI
        TEXTUAL-CONVENTION
                FROM SNMPv2-TC
        ericssonModules
                FROM ERICSSON-TOP-MIB;

ericssonAlarmTCMIB MODULE-IDENTITY
        LAST-UPDATED "200810170000Z"
        ORGANIZATION "Ericsson AB"
        CONTACT-INFO
                "Email: snmp.mib.contact@ericsson.com "
        DESCRIPTION
                "This MIB defines textual conventions used by the
                ERICSSON-ALARM-MIB.
                
                See also Documentation and Use of the Ericsson
                SNMP Fault Management MIB, Document number
                EAB/OP-07:0139.

                Document number: 3/196 03-CXC 172 7549, Rev A"
        REVISION      "200810170000Z"
        DESCRIPTION
                "Initial version of this MIB module."
        ::= { ericssonModules 3 }

--=======================
--==Textual conventions==
--=======================

EriAlarmType ::= TEXTUAL-CONVENTION
        DISPLAY-HINT "d"
        STATUS current
        DESCRIPTION
                "A unique identification of the fault, not
                including the managed object.  Alarm types are
                used to identify if alarms indicate the same
                problem or not, for lookup into external alarm
                documentation, etc.  A unique alarm type is
                identified using the combination of two instances
                of EriAlarmType. Different managed object
                types and instances can share alarm types.  But
                if the same managed object reports the same alarm
                type, it is to be considered to be the same alarm
                state. The alarm type is a simplification of the
                different X.733 and 3GPP alarm IRP alarm
                correlation mechanisms based on EventType,
                ProbableCause, SpecificProblem and
                NotificationId."
        SYNTAX Unsigned32

EriAlarmIndex ::= TEXTUAL-CONVENTION
        DISPLAY-HINT "d"
        STATUS current
        DESCRIPTION
                "Index used in the active alarm table.  A row
                shall never change its index during the lifetime
                of the entry; for example renumbering entries is
                not allowed when entries are deleted.
                Renumbering after an agent restart is allowed.
                Note that this index shall not be used to
                identify alarms when performing
                resynchronization, etc. The logical identity for
                an alarm instance is the managed object and alarm
                type."
        SYNTAX Unsigned32

EriAdditionalText ::= TEXTUAL-CONVENTION
        DISPLAY-HINT "1a"
        STATUS current
        DESCRIPTION
                "The string used in additional text
                notifications. This MUST contain enough
                information for an operator to be able to
                understand the problem. If this string contains
                structure, this format should be clearly
                documented for programs to be able to parse that
                information. This is a small size range in order
                to guarantee delivery of notifications without
                fragmentation. There is a corresponding textual
                convention, EriLargeAdditionalText, to be used
                for scalar and columnar objects.  The string
                should adhere to the rules for SnmpAdminString of
                SNMPv3 framework MIBs."
        REFERENCE
                "snmpFrameworkMIB in RFC 3411 defines
                SnmpAdminString"
        SYNTAX OCTET STRING(SIZE(4..256))

EriLargeAdditionalText ::= TEXTUAL-CONVENTION
        DISPLAY-HINT "1a"
        STATUS current
        DESCRIPTION
                "The string used in additional text. This MUST
                contain enough information for an operator to be
                able to understand the problem. If this string
                contains structure, this format should be clearly
                documented for programs to be able to parse that
                information. This is a large additional text to
                be used in tables. There is a corresponding
                textual convention to be used in alarm
                notifications, EriAdditionalText.  The string
                should adhere to the rules for SnmpAdminString of
                SNMPv3 framework MIBs."
        REFERENCE
                "snmpFrameworkMIB in RFC 3411 defines
                SnmpAdminString"
        SYNTAX OCTET STRING(SIZE(4..512))        
        
EriAlarmSpecificProblem ::= TEXTUAL-CONVENTION
        DISPLAY-HINT "1a"
        STATUS current
        DESCRIPTION
                "Unique string for the Alarm Type. No different
                alarm types may share specific problem. Specific
                Problem and Alarm Type have a one-to-one
                correspondance."
        SYNTAX OCTET STRING(SIZE(4..64))
        
EriAlarmSequenceNumber ::= TEXTUAL-CONVENTION
        DISPLAY-HINT "d"
        STATUS current
        DESCRIPTION
                "This is a monotonically increasing counter. It
                is increased every time a notification is sent.
                The value is NOT increased for heartbeat
                notifications.  It is carried as a varbind in the
                alarm notifications as well as in the heartbeat
                notifications.  Management systems can use these
                varbinds to detect lost notifications."
        SYNTAX Unsigned32
END