--    Copyright 2010 Electroline Equipment Inc.                                   
--    All Rights Reserved                                                                          
--                                                                          
--                                                                          
--                                                                          
--**************************************************************************
--    Filename: ELECTROLINE-DVM-STATUS.mib
--    Author:   ALAIN LECLERC
--    Creation Date: 2010-09-14
--
--**************************************************************************
--    Description:
--
--	This file contains the MIB definition of the Status branch 
--  for the DVM products.
--		
--**************************************************************************
--    Revision History:
--    2010-09-14    ALAIN LECLERC      First Release
--**************************************************************************

ELECTROLINE-DVM-STATUS-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY,OBJECT-TYPE,Integer32 FROM SNMPv2-SMI
    RowStatus  FROM SNMPv2-TC        
    dvmStatus, electrolineDVM FROM ELECTROLINE-DVM-ROOT-MIB
    NetworkAddress FROM RFC1155-SMI
    DisplayString  FROM RFC1213-MIB   
    
    ifIndex   FROM IF-MIB;            -- [RFC2863]


-- Textual Conventions
TenthdBmV ::= TEXTUAL-CONVENTION
        DISPLAY-HINT "d-1"
        STATUS       current
        DESCRIPTION
            "This data type represents power levels that are normally
             expressed in dBmV. Units are in tenths of a dBmV;
             for example, 5.1 dBmV will be represented as 51."
        SYNTAX       Integer32
        
-- Textual Conventions
TenthdB ::= TEXTUAL-CONVENTION
        DISPLAY-HINT "d-1"
        STATUS       current
        DESCRIPTION
            "This data type represents the pad value that are normally
             expressed in dB. Units are in tenths of a dB;
             for example, 5.1 dB will be represented as 51."
        SYNTAX       Integer32

-- Textual Conventions
HundredthsVolts ::= TEXTUAL-CONVENTION
         DISPLAY-HINT "d-2"   
         STATUS       current
         DESCRIPTION
            "suggests that a Hundredths value of 1234 be rendered as 12.34 Volts"
         SYNTAX     INTEGER (0..65535)


    
-- **************************************************************************
-- * ELECTROLINE MISC. Statuses
-- * 
-- **************************************************************************
dvmNetworkAddress OBJECT-TYPE
	SYNTAX NetworkAddress
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
		"This is the RF IP address assigned by the DHCP."
	::= { dvmStatus 1 }

dvmInternalTemperature  OBJECT-TYPE
     SYNTAX INTEGER (-60..130)
     ACCESS read-only
     STATUS current
     DESCRIPTION 
          "Measured temperature inside the NE's case/housing.
          Units degrees Celsius."
     ::= { dvmStatus 2 }

--**************************************************************************
--  Information on the hardware demodulator.
--  The DVM has attenuator pad in the downstream path and has a fix
--  attenuation pad also.  We need to take that in the account for
--	downstream and upstream power repport.
--**************************************************************************
dvmIfDownstreamChannelTable OBJECT-TYPE
     SYNTAX      SEQUENCE OF DvmIfDownstreamChannelEntry
     MAX-ACCESS  not-accessible
     STATUS      current
     DESCRIPTION
         "This table describes the attributes of downstream
          channels (frequency bands) at Dvm's input."
     ::= { dvmStatus 3 }

dvmIfDownstreamChannelEntry OBJECT-TYPE
     SYNTAX      DvmIfDownstreamChannelEntry
     MAX-ACCESS  not-accessible
     STATUS      current
     DESCRIPTION
         "An entry provides a list of attributes for a single
          downstream channel."
     INDEX { ifIndex }
     ::= { dvmIfDownstreamChannelTable 1 }

DvmIfDownstreamChannelEntry ::= SEQUENCE {
         dvmIfDownChannelId               Integer32,
         dvmIfDownChannelFrequency        Integer32,
         dvmIfDownChannelWidth            Integer32,
         dvmIfDownChannelModulation       INTEGER,
         dvmIfDownChannelInterleave       INTEGER,
         dvmIfDownChannelPower            TenthdBmV,
         dvmIfDownChannelAnnex            INTEGER,
         dvmIfDownChannelSymbolRate		  Integer32,	
         dvmIfDownChannelTunerModule	  Integer32
 }

dvmIfDownChannelId OBJECT-TYPE
     SYNTAX      Integer32 (0..255)
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
         "The Cable Modem Termination System identification of the
          downstream channel within this particular MAC interface.
          if the interface is down, the object returns the most
          current value.  If the downstream channel ID is unknown,
          this object returns a value of 0."
     ::= { dvmIfDownstreamChannelEntry 1 }

dvmIfDownChannelFrequency OBJECT-TYPE
     SYNTAX      Integer32 (0..1000000000)
     UNITS       "hertz"
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
         "The center of the downstream frequency associated with
          this channel.  This object will return the current tuner
          frequency."
     ::= { dvmIfDownstreamChannelEntry 2 }

dvmIfDownChannelWidth OBJECT-TYPE
     SYNTAX      Integer32 (0..16000000)
     UNITS       "hertz"
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
         "The bandwidth of this downstream channel.  Most
          implementations are expected to support a channel width
          of 6 MHz (North America) and/or 8 MHz (Europe).  See the
          associated compliance object for a description of the
          valid channel widths for this object."
     ::= { dvmIfDownstreamChannelEntry 3 }

dvmIfDownChannelModulation OBJECT-TYPE
     SYNTAX      INTEGER {
         unknown(1),
         other(2),
         qam64(3),
         qam256(4)
     }
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
         "The modulation type associated with this downstream
          channel.  If the interface is down, this object either
          returns the configured value (CMTS), the most current
          value (CM), or the value of unknown(1).  See the
          associated conformance object for write conditions and
          limitations.  See the reference for specifics on the
          modulation profiles implied by qam64 and qam256."
     ::= { dvmIfDownstreamChannelEntry 4 }

dvmIfDownChannelInterleave OBJECT-TYPE
     SYNTAX      INTEGER {
         unknown(1),
         other(2),
         taps8Increment16(3),
         taps16Increment8(4),
         taps32Increment4(5),
         taps64Increment2(6),
         taps128Increment1(7),
         taps12increment17(8)
     }
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
         "The Forward Error Correction (FEC) interleaving used
          for this downstream channel.
          Values are defined as follows:
          taps8Increment16(3):   protection 5.9/4.1 usec,
                                 latency .22/.15 msec
          taps16Increment8(4):   protection 12/8.2 usec,
                                 latency .48/.33 msec
          taps32Increment4(5):   protection 24/16 usec,
                                 latency .98/.68 msec
          taps64Increment2(6):   protection 47/33 usec,
                                 latency 2/1.4 msec
          taps128Increment1(7):  protection 95/66 usec,
                                 latency 4/2.8 msec
          taps12increment17(8):  protection 18/14 usec,
                                 latency 0.43/0.32 msec

         The value 'taps12increment17' is supported by EuroDOCSIS
         cable systems only, and the others by DOCSIS cable systems.

          If the interface is down, this object either returns
          the configured value (CMTS), the most current value (CM),
          or the value of unknown(1).
          The value of other(2) is returned if the interleave
          is known but not defined in the above list.
          See the associated conformance object for write
          conditions and limitations.  See the reference for the FEC
          configuration described by the setting of this object."
     ::= { dvmIfDownstreamChannelEntry 5 }

dvmIfDownChannelPower OBJECT-TYPE
     SYNTAX      TenthdBmV
     UNITS       "dBmV"
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
         "At the DVM, the received power level at the RF front-end.
          If the interface is down, the value of 0."
     ::= { dvmIfDownstreamChannelEntry 6 }

dvmIfDownChannelAnnex OBJECT-TYPE
     SYNTAX      INTEGER {
         unknown(1),
         other(2),
         annexA(3),
         annexB(4),
         annexC(5)
     }
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
         "The value of this object indicates the conformance of
          the implementation to important regional cable standards.
          annexA : Annex A from ITU-T J.83 is used.
                   (equivalent to EN 300 429)
          annexB : Annex B from ITU-T J.83 is used.
          annexC : Annex C from ITU-T J.83 is used."
     ::= { dvmIfDownstreamChannelEntry 7 }

dvmIfDownChannelSymbolRate OBJECT-TYPE
     SYNTAX      Integer32 (0..1000000000)
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
         "This value indicates the channel rate in Symbol per second"
     ::= { dvmIfDownstreamChannelEntry 8 } 

dvmIfDownChannelTunerModule OBJECT-TYPE
     SYNTAX      Integer32 (-1..6)
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
         "The value of this object indicates the tuner module number 
          on which the hardware channel is mapped.
          1 and 2 are wideband tuners internal to the BCM3380;
          3 to 6 are external narrowband tuners
          -1 unmapped"
     ::= { dvmIfDownstreamChannelEntry 9 }


dvmIfUpstreamChannelTable OBJECT-TYPE
     SYNTAX      SEQUENCE OF DvmIfUpstreamChannelEntry
     MAX-ACCESS  not-accessible
     STATUS      current
     DESCRIPTION
         "This table describes the attributes of attached upstream
          channels."
     ::= { dvmStatus 4 }

dvmIfUpstreamChannelEntry OBJECT-TYPE
     SYNTAX      DvmIfUpstreamChannelEntry
     MAX-ACCESS  not-accessible
     STATUS      current
     DESCRIPTION
         "List of attributes for a single upstream channel."
     INDEX { ifIndex }
     ::= { dvmIfUpstreamChannelTable 1 }

DvmIfUpstreamChannelEntry ::= SEQUENCE {
         dvmIfUpChannelId                     Integer32,
         dvmIfUpChannelFrequency              Integer32,
         dvmIfUpChannelWidth                  Integer32,
         dvmIfUpChannelTxPower				  TenthdBmV,
         dvmIfUpChannelSymbolRate			  Integer32
     }

dvmIfUpChannelId OBJECT-TYPE
     SYNTAX      Integer32 (0..255)
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
         "The CMTS identification of the upstream channel."
     ::= { dvmIfUpstreamChannelEntry 1 }

dvmIfUpChannelFrequency OBJECT-TYPE
     SYNTAX      Integer32 (0..1000000000)
     UNITS       "hertz"
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
         "The center of the frequency band associated with this
          upstream interface.  This object returns 0 if the frequency
          is undefined or unknown.  Minimum permitted upstream
          frequency is 5,000,000 Hz for current technology.  See
          the associated conformance object for write conditions
          and limitations."
     ::= { dvmIfUpstreamChannelEntry 2 }

dvmIfUpChannelWidth OBJECT-TYPE
     SYNTAX      Integer32 (0..64000000)
     UNITS       "hertz"
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
         "The bandwidth of this upstream interface.  This object
          returns 0 if the interface width is undefined or unknown.
          Minimum permitted interface width is currently 200,000 Hz.
          See the associated conformance object for write conditions
          and limitations."
     ::= { dvmIfUpstreamChannelEntry 3 }

dvmIfUpChannelTxPower OBJECT-TYPE
     SYNTAX      TenthdBmV
     UNITS       "dBmV"
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
         "The operational transmit power for the attached upstream
          channel at the output of the DVM.E"
     ::= { dvmIfUpstreamChannelEntry 4 }


dvmIfUpChannelSymbolRate OBJECT-TYPE
     SYNTAX      Integer32 (0..1000000000)
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
         "This value indicates the channel rate in kSymbol per second"
     ::= { dvmIfUpstreamChannelEntry 5 } 
 

dvmIfSignalQualityTable OBJECT-TYPE
     SYNTAX      SEQUENCE OF DvmIfSignalQualityEntry
     MAX-ACCESS  not-accessible
     STATUS      current
     DESCRIPTION
         "At the CM, describes the PHY signal quality of downstream
          channels."
     ::= { dvmStatus 5 }

dvmIfSignalQualityEntry OBJECT-TYPE
     SYNTAX      DvmIfSignalQualityEntry
     MAX-ACCESS  not-accessible
     STATUS      current
     DESCRIPTION
         "At the CM, this object describes the PHY characteristics of
          a downstream channel."
     INDEX { ifIndex }
     ::= { dvmIfSignalQualityTable 1 }

DvmIfSignalQualityEntry ::= SEQUENCE {
         dvmIfSigQUnerroreds          Counter32,
         dvmIfSigQCorrecteds          Counter32,
         dvmIfSigQUncorrectables      Counter32,
         dvmIfSigQSignalNoise         TenthdB,
         dvmIfSigQMicroreflections    Integer32
}

dvmIfSigQUnerroreds OBJECT-TYPE
     SYNTAX      Counter32
     UNITS       "codewords"
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
         "Codewords received on this channel without error.
          This includes all codewords, whether or not they
          were part of frames destined for this device.
          Discontinuities in the value of this counter can occur
          at reinitialization of the managed system."
     ::= { dvmIfSignalQualityEntry 1 }

dvmIfSigQCorrecteds OBJECT-TYPE
     SYNTAX      Counter32
     UNITS       "codewords"
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
         "Codewords received on this channel with correctable
          errors.  This includes all codewords, whether or not
          they were part of frames destined for this device.
          Discontinuities in the value of this counter can occur
          at reinitialization of the managed system."
     ::= { dvmIfSignalQualityEntry 2 }

dvmIfSigQUncorrectables OBJECT-TYPE
     SYNTAX      Counter32
     UNITS       "codewords"
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
         "Codewords received on this channel with uncorrectable
          errors.  This includes all codewords, whether or not
          they were part of frames destined for this device.
          Discontinuities in the value of this counter can occur
          at reinitialization of the managed system."
     ::= { dvmIfSignalQualityEntry 3 }

dvmIfSigQSignalNoise OBJECT-TYPE
     SYNTAX      TenthdB
     UNITS       "TenthdB"
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
         "Signal/Noise ratio as perceived for this channel.
          At the CM, this object  describes the Signal/Noise of the
          downstream channel."
     ::= { dvmIfSignalQualityEntry 4 }
     
dvmIfSigQMicroreflections OBJECT-TYPE
     SYNTAX      Integer32 (0..255)
     UNITS       "-dBc"
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
         "Microreflections, including in-channel response
          as perceived on this interface, measured in dBc below
          the signal level.
          This object is not assumed to return an absolutely
          accurate value, but it gives a rough indication
          of microreflections received on this interface.
          It is up to the implementer to provide information
          as accurately as possible."
     ::= { dvmIfSignalQualityEntry 5 }


dvmRxAttenuatorPad  OBJECT-TYPE
     SYNTAX TenthdB
     UNITS       "dB"
     ACCESS read-only
     STATUS current
     DESCRIPTION 
          "The Rx Attenuator pad value.
           If value is -2,0 the pad sens technology is not connected.  Check the wiring inside the DVM
           If value is -1,0 there is no pad connected.
          "
     ::= { dvmStatus 6 }

dvmTxAttenuatorPad  OBJECT-TYPE
     SYNTAX TenthdB
     UNITS       "dB"
     ACCESS read-only
     STATUS current
     DESCRIPTION 
          "The Tx Attenuator pad value.
           If value is -2,0 the pad sens technology is not connected.  Check the wiring inside the DVM
           If value is -1,0 there is no pad connected.
          "
     ::= { dvmStatus 7 }

dvmRxEqualyzerPlugin  OBJECT-TYPE
     SYNTAX      INTEGER {
         unknown(-2),
         noEqualyzer(-1),
         cableSim0ft(0),
         cableSim75ft(1),
         cableSim150ft(2),
         equalyzer4dB(20),
         equalyzer8dB(21)
     }
     ACCESS read-only
     STATUS current
     DESCRIPTION 
          "The Equalyzer plugin value.  Could be a cable simulator or a equilazer.
           If value is -2,0 the pad sens technology is not connected.  Check the wiring inside the DVM
           If value is -1,0 there is no pad connected."
     ::= { dvmStatus 8 }

dvmAcInputVoltage OBJECT-TYPE
     SYNTAX INTEGER ( 0..65535 )
     UNITS       "1VAC"
     ACCESS read-only
     STATUS current
     DESCRIPTION
           "Returns the dvm Ac input voltage. Units 1VAC."
     ::= { dvmStatus 9 }

dvmNumberDCPowerSupply OBJECT-TYPE
     SYNTAX INTEGER ( 0..16 )
     ACCESS read-only
     STATUS current
     DESCRIPTION
          "Number of entries in the internal DC power supply table
          A zero entry means the table does not exist and the functional
          area is not present in the device."
     ::= { dvmStatus 10 }

dvmTunerHeaterStatus OBJECT-TYPE
	SYNTAX INTEGER {on(1), off(2)}
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
		"This mib shows the tuner heater block activation status."		
	::= { dvmStatus 12 }


dvmDCPowerTable OBJECT-TYPE
     SYNTAX SEQUENCE OF DvmDCPowerEntry
     ACCESS not-accessible
     STATUS current
     DESCRIPTION
          "A table containing information about the Regulated Power."
     ::= { dvmStatus 11 }

dvmDCPowerEntry OBJECT-TYPE
     SYNTAX DvmDCPowerEntry
     ACCESS not-accessible
     STATUS current
     DESCRIPTION
          "A list of information about the Regulated Power."
     INDEX { dvmDCPowerIndex }
     ::= { dvmDCPowerTable 1 }

DvmDCPowerEntry ::=
     SEQUENCE
     {
          dvmDCPowerIndex
               INTEGER,
          dvmDCPowerVoltage
               INTEGER,
          dvmDCPowerName
               DisplayString
     }

dvmDCPowerIndex OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS current
     DESCRIPTION
          "Index into the dvmDCPowerTable."
     ::= { dvmDCPowerEntry 1 }

dvmDCPowerVoltage OBJECT-TYPE
     SYNTAX HundredthsVolts
     UNITS       "0.01Vdc"
     ACCESS read-only
     STATUS current
     DESCRIPTION
          "Returns the regulated power voltage.  Units in 0.01 Volts."
     ::= { dvmDCPowerEntry 2 }

dvmDCPowerName OBJECT-TYPE
     SYNTAX DisplayString
     ACCESS read-only
     STATUS current
     DESCRIPTION
          "Identifies the Physical name of the Power Supply.  For example:
     		3.3V Supply"
     ::= { dvmDCPowerEntry 3 }



END