-- EKINOPS-Pmvoa.TXT:  MIB
--
--MIB Part Number:3MI00124AAAA
--MIB Version:02
--
-- Copyright (c) 2016 by Ekinops
-- All rights reserved.
-- 
-- *****************************************************************

EKINOPS-Pmvoa-MIB DEFINITIONS ::= BEGIN

IMPORTS
	ekinops,
	EkiState,
	EkiOnOff,
	EkiMode,
	EkiProtocol,
	EkiApiState,
	EkiSynchroMode,
	EkiMeasureType
			FROM EKINOPS-MIB
        MODULE-IDENTITY,
        OBJECT-TYPE,
        NOTIFICATION-TYPE,
	Unsigned32,
	Integer32,
	Counter32,
	IpAddress                
        		FROM SNMPv2-SMI
 	TEXTUAL-CONVENTION,
	DisplayString
                FROM SNMPv2-TC;

modulePmvoa MODULE-IDENTITY
        LAST-UPDATED "201612210000Z"
        ORGANIZATION "Ekinops"
        CONTACT-INFO
         "Ekinops

          3, rue Blaise Pascal
          F-22300 Lannion / FRANCE

          Tel : +33 (0)2 96 05 00 30
          Fax : +33 (0)2 96 48 62 39

          E-mail: support@ekinops.fr"
        DESCRIPTION
          "Creation."

	REVISION "201612210000Z"
	DESCRIPTION
	  "Creation for PMVOA"
        ::= { ekinops 84 }



--- *****************************************************
---     LEAF LEVEL 2
--- *****************************************************


pmvoaalarms OBJECT IDENTIFIER ::= { modulePmvoa 2 }	
pmvoaAlmOther OBJECT IDENTIFIER ::= { pmvoaalarms 1 }
pmvoaAlmOtherNurg OBJECT IDENTIFIER ::= { pmvoaAlmOther 1 }
pmvoaAlmOtherUrg OBJECT IDENTIFIER ::= { pmvoaAlmOther 2 }
pmvoaAlmOtherCrit OBJECT IDENTIFIER ::= { pmvoaAlmOther 3 }

pmvoaAlmClient OBJECT IDENTIFIER ::= { pmvoaalarms 2 }
pmvoaAlmClientNurg OBJECT IDENTIFIER ::= { pmvoaAlmClient 1 }
pmvoaAlmClientUrg OBJECT IDENTIFIER ::= { pmvoaAlmClient 2 }
pmvoaAlmClientCrit OBJECT IDENTIFIER ::= { pmvoaAlmClient 3 }
	
pmvoaAlmLine OBJECT IDENTIFIER ::= { pmvoaalarms 3 }
pmvoaAlmLineNurg OBJECT IDENTIFIER ::= { pmvoaAlmLine 1 }
pmvoaAlmLineUrg OBJECT IDENTIFIER ::= { pmvoaAlmLine 2 }
pmvoaAlmLineCrit OBJECT IDENTIFIER ::= { pmvoaAlmLine 3 }



pmvoameasures OBJECT IDENTIFIER ::= { modulePmvoa 3 }	
pmvoaMesrOther OBJECT IDENTIFIER ::= { pmvoameasures 1 }	
pmvoaMesrClient OBJECT IDENTIFIER ::= { pmvoameasures 2 }	
pmvoaMesrLine OBJECT IDENTIFIER ::= { pmvoameasures 3 }	



pmvoacontrolsWrite OBJECT IDENTIFIER ::= { modulePmvoa 6 }
pmvoaCtrlOther OBJECT IDENTIFIER ::= { pmvoacontrolsWrite 1 }
pmvoaCtrlClient OBJECT IDENTIFIER ::= { pmvoacontrolsWrite 2 }
pmvoaCtrlLine OBJECT IDENTIFIER ::= { pmvoacontrolsWrite 3 }

pmvoari OBJECT IDENTIFIER ::= { modulePmvoa 7 }
pmvoariTable OBJECT IDENTIFIER ::= { pmvoari 1 }

pmvoadownload OBJECT IDENTIFIER ::= { modulePmvoa 8 }
pmvoaDwlOther OBJECT IDENTIFIER ::= { pmvoadownload 1 }
pmvoaDwlClient OBJECT IDENTIFIER ::= { pmvoadownload 2 }
pmvoaDwlLine OBJECT IDENTIFIER ::= { pmvoadownload 3 }


pmvoaConfig OBJECT IDENTIFIER ::= { modulePmvoa 9 }

pmvoatraps OBJECT IDENTIFIER ::= { modulePmvoa 10 }



--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     TEXTUAL-CONVENTION
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************

PmvoaMode ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION "Mode for the SFP VOA"
    SYNTAX INTEGER {
		attenuationctrl(0),
		powerctrl(1)
           }

--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     REMOTE INVENTORY
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************

pmvoaRinvReloadInventory OBJECT-TYPE
  SYNTAX EkiOnOff
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
        "Reload the inventory: This OID triggers an 
         inventory reload."
  ::= { pmvoari 2 }

pmvoaRinvHwPlatform OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
        "HW platform description: This OID contains the 
         description of the Hardware platform."
  ::= { pmvoari 3 }
  
pmvoaRinvModulePlatform OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
        "Module platform description: This OID contains the 
         description of the Module."
  ::= { pmvoari 4 }
  
pmvoaRinvSwPlatform OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
        "SW platform description: This OID contains the 
         description of the Software platform."
  ::= { pmvoari 5 }
  
pmvoaRinvGwPlatform OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
        "GW platform description: This OID contains the 
         description of the Gateware platform."
  ::= { pmvoari 6 }


--- ***Clients***

---pmvoaRinvSfpTable OBJECT-TYPE
---      SYNTAX  SEQUENCE OF PmvoaRinvSfpEntry
---      MAX-ACCESS  not-accessible
---      STATUS  current
---      DESCRIPTION
---              "List of the SFPs on the selected module"
---      ::= { pmvoariTable 1 }

---pmvoaRinvSfpEntry OBJECT-TYPE
---        SYNTAX  PmvoaRinvSfpEntry
---        MAX-ACCESS  not-accessible
---        STATUS  current
---        DESCRIPTION
---              "Row definition for the SFP table"
---        INDEX   { pmvoaRinvSfpIndex }
---        ::= { pmvoaRinvSfpTable 1 }
    


---PmvoaRinvSfpEntry::=
---        SEQUENCE {
---          pmvoaRinvSfpIndex 
---              Integer32,
---          pmvoaRinvsfp
---             DisplayString
---        }


---    pmvoaRinvSfpIndex OBJECT-TYPE
---        SYNTAX  Integer32(1..16)
---        MAX-ACCESS  read-only
---        STATUS  current
---        DESCRIPTION
---              "Index for SFP table"
---        ::= { pmvoaRinvSfpEntry 1 }


---    pmvoaRinvsfp OBJECT-TYPE
---      SYNTAX  DisplayString
---        MAX-ACCESS  read-only
---        STATUS  current
---        DESCRIPTION
---              "Inventory for the SFP: This OID contains the inventory for the SFP"
---        ::= { pmvoaRinvSfpEntry 2 }


--- ***Lines***

pmvoaRinvLineTable OBJECT-TYPE
      SYNTAX  SEQUENCE OF PmvoaRinvLineEntry
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
              "List of the SFPs on the selected module"
      ::= { pmvoariTable 2 }

pmvoaRinvLineEntry OBJECT-TYPE
        SYNTAX  PmvoaRinvLineEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
              "Row definition for the SFP table"
        INDEX   { pmvoaRinvLineIndex }
        ::= { pmvoaRinvLineTable 1 }
    


PmvoaRinvLineEntry::=
        SEQUENCE {
          pmvoaRinvLineIndex 
              Integer32,
          pmvoaRinvxfpLine
              DisplayString
        }


    pmvoaRinvLineIndex OBJECT-TYPE
        SYNTAX  Integer32(1..16)
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
              "Index for SFP table"
        ::= { pmvoaRinvLineEntry 1 }


    pmvoaRinvxfpLine OBJECT-TYPE
        SYNTAX  DisplayString
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
              "Inventory for the XFP: This OID contains the inventory for the XFP"
        ::= { pmvoaRinvLineEntry 2 }











--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     ALARMS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the synthAlm0 article
--- *****************************************************
pmvoaAlmsynthAlm0 OBJECT IDENTIFIER ::= { pmvoaAlmOtherCrit 0 }




pmvoaAlmDefFuseB OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Fuse B Fail :This OID indicates 
        that the fuse of the power input 
        B is in fail condition <Help> Status 
        of the Fuse B <Condtype> DEF_FUSE_B 
        <Probcause> powerProblem (36) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmvoaAlmsynthAlm0 16 }



pmvoaAlmDefFuseA OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Fuse A Fail :This OID indicates 
        that the fuse of the power input 
        A is in fail condition <Help> Status 
        of the Fuse A <Condtype> DEF_FUSE_A 
        <Probcause> powerProblem (36) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmvoaAlmsynthAlm0 15 }



pmvoaAlmModGlobFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Module Failure :This OID is set 
        on detection of a failure originating 
        from the RM <Help> This alarm is 
        set on detection of a failure originating 
        from the equipment <Condtype> MOD_GLOB_FAIL 
        <Probcause> other (1) <Alarmtype> 
        synthesisAlarm (12)  <Polarity> 
        (2) 
        "
	  ::= { pmvoaAlmsynthAlm0 9 }



--- *****************************************************
---     LEAF for the synthAlm2 article
--- *****************************************************
pmvoaAlmsynthAlm2 OBJECT IDENTIFIER ::= { pmvoaAlmOtherNurg 2 }




pmvoaAlmCorrelatOff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Not Used :This OID, when set,
         indicates that alarm correlation 
        is not being performed. <Condtype> 
        CORRELAT_OFF <Probcause> informationalStatus(1000) 
        <Alarmtype> other (1) <Polarity> 
        (2) 
        "
	  ::= { pmvoaAlmsynthAlm2 4 }



pmvoaAlmConfTableLoad OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        PM Configuration Load :This OID 
         is at 1 during the loading of
         configuration tables in the modules 
        RAM. <Condtype> CONF_TABLE_LOAD 
        <Probcause> informationalStatus(1000) 
        <Alarmtype> other (1) <Polarity> 
        (2) 
        "
	  ::= { pmvoaAlmsynthAlm2 3 }



pmvoaAlmInvUpload OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Inventory Upload :This OID is
         at 1 during the uploading of PM 
        inventory information. <Condtype> 
        INV_UPLOAD <Probcause> informationalStatus(1000) 
        <Alarmtype> other (1) <Polarity> 
        (2) 
        "
	  ::= { pmvoaAlmsynthAlm2 2 }



pmvoaAlmConfTableSave OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        PM Configuration Save :This OID 
        is at 1 during the saving of a
         new configuration table in the 
        module Flash memory. <Condtype> 
        CONF_TABLE_SAVE <Probcause> informationalStatus(1000) 
        <Alarmtype> other (1) <Polarity> 
        (2) 
        "
	  ::= { pmvoaAlmsynthAlm2 1 }



--- *********************************************************
---     TABLE for the pmvoaAlmsynthAlmLine articles
--- *********************************************************

pmvoaAlmsynthAlmLineTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PmvoaAlmsynthAlmLineEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pmvoaAlmsynthAlmLine Article
        "
	::= { pmvoaAlmLineCrit 24 }


pmvoaAlmsynthAlmLineEntry OBJECT-TYPE
	SYNTAX PmvoaAlmsynthAlmLineEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pmvoaAlmsynthAlmLine 
        table
        "
	INDEX   { pmvoaAlmsynthAlmLineIndex }
	::= { pmvoaAlmsynthAlmLineTable 1 }


PmvoaAlmsynthAlmLineEntry ::=
	SEQUENCE {
	pmvoaAlmsynthAlmLineIndex
		INTEGER,
	pmvoaAlmLineFailPortn
		EkiOnOff,
	pmvoaAlmLineOosPortn
		EkiOnOff,
	pmvoaAlmLineHwFailPortn
		EkiOnOff,
	pmvoaAlmLineSfpVoaAbsentPortn
		EkiOnOff
	}


pmvoaAlmsynthAlmLineIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pmvoaAlmsynthAlmLine 
        table
        "
	::= { pmvoaAlmsynthAlmLineEntry 1 }


pmvoaAlmLineFailPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Port Failure :This OID indicates 
        a failure on the line port <Help> 
        This alarm indicates a failure
         on the line port <Condtype> LINE_FAIL 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	::= { pmvoaAlmsynthAlmLineEntry 13 }


pmvoaAlmLineOosPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        VOA Module Out Of Service :This 
        OID indicates that the SFP is In 
        Service or Out of Service<Help> 
         This status indicates if the VOA 
        SFP is in service <Condtype> LINE_OOS 
        <Probcause> informationalStatus(1000) 
        <Alarmtype> other (1) <Polarity> 
        (2) 
        "
	::= { pmvoaAlmsynthAlmLineEntry 7 }


pmvoaAlmLineHwFailPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Port HW Failure :This OID 
        indicates a failure on line port, 
        most probably caused by a HW issue 
        <Help> This alarm indicates a failure 
        on line port, most probably caused 
        by a HW issue <Condtype> LINE_HW_FAIL 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	::= { pmvoaAlmsynthAlmLineEntry 5 }


pmvoaAlmLineSfpVoaAbsentPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        VOA Module Absent :This OID indicates 
        that the VOA SFP is not present. 
         <Help> This alarm indicates if 
        the VOA SFP is absent  <Condtype> 
        LINE_SFP_VOA_ABSENT <Probcause> 
        inputOutputDeviceError (24) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        <Event> ObjectCDSingleClientInv
        "
	::= { pmvoaAlmsynthAlmLineEntry 2 }


--- *********************************************************
---     TABLE for the pmvoaAlmlineAlm articles
--- *********************************************************

pmvoaAlmlineAlmTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PmvoaAlmlineAlmEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pmvoaAlmlineAlm Article
        "
	::= { pmvoaAlmLineCrit 40 }


pmvoaAlmlineAlmEntry OBJECT-TYPE
	SYNTAX PmvoaAlmlineAlmEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pmvoaAlmlineAlm 
        table
        "
	INDEX   { pmvoaAlmlineAlmIndex }
	::= { pmvoaAlmlineAlmTable 1 }


PmvoaAlmlineAlmEntry ::=
	SEQUENCE {
	pmvoaAlmlineAlmIndex
		INTEGER,
	pmvoaAlmLossInputPowerPortn
		EkiOnOff,
	pmvoaAlmTempLowAlarmPortn
		EkiOnOff,
	pmvoaAlmTempHighAlarmPortn
		EkiOnOff,
	pmvoaAlmLossOutputPowerPortn
		EkiOnOff,
	pmvoaAlmOutputErrorPortn
		EkiOnOff
	}


pmvoaAlmlineAlmIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pmvoaAlmlineAlm 
        table
        "
	::= { pmvoaAlmlineAlmEntry 1 }


pmvoaAlmLossInputPowerPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Loss Of Input Power :This OID
         indicates that the VOA SFP attenuation 
        has no input power) <Help> Alarm 
        indicating that the VOA SFP attenuation 
        has no input power <Condtype> LOSS_INPUT_POWER_1 
        <Probcause> lossOfSignal(30) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	::= { pmvoaAlmlineAlmEntry 6 }


pmvoaAlmTempLowAlarmPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        VOA Temp Low Alarm :OID indicates 
        the VOA SFP Temperature is lower 
        than the threshold value written 
        in the SFP <Help> Alarm indicating 
        that the VOA SFP Temperature is 
        lower than the threshold value
         written in the SFP <Condtype>
         TEMP_LOW_ALARM_1 <Probcause> transmitterFailure 
        (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	::= { pmvoaAlmlineAlmEntry 5 }


pmvoaAlmTempHighAlarmPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        VOA Temp High Alarm :This OID
         indicates the VOA SFP Temperature 
        is higher than the threshold value 
        written in the SFP <Help> Alarm 
        indicating that the VOA SFP Temperature 
        is higher than the threshold value 
        written in the SFP <Condtype> TEMP_HIGH_ALARM_1 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	::= { pmvoaAlmlineAlmEntry 4 }


pmvoaAlmLossOutputPowerPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Loss Of Output Power :This OID 
        indicates that the VOA SFP attenuation 
        is infinite (no output power) <Help> 
        Alarm indicating that the VOA SFP 
        attenuation is infinite (no output 
        power) <Condtype> LOSS_OUTPUT_POWER_1 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	::= { pmvoaAlmlineAlmEntry 3 }


pmvoaAlmOutputErrorPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        VOA Module Output power Failure 
        :When configured in Constant Output 
        Power, this OID indicates the required 
        output power cant be reached 
         <Help> When configured in Constant 
        output power, this alarm indicates 
        the required output power cant 
        be reached <Condtype> OUTPUT_ERROR_1 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	::= { pmvoaAlmlineAlmEntry 2 }







--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     CONTROLS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the confMgnt1 article
--- *****************************************************
pmvoaCtrlconfMgnt1 OBJECT IDENTIFIER ::= { pmvoaCtrlOther 1 }




pmvoaCtrlConf2Clear1 OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Clear Configuration Tables :This 
        OID clears the configuration tables 
        from configuration2 in the flash. 
         <Help>  This control restores
         the default configuration of the 
        module
        "
	  ::= { pmvoaCtrlconfMgnt1 14 }



pmvoaCtrlConf2Flash1 OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Write Configuration Tables :This 
        OID saves the current configuration 
        of the PM as configuration2 in
         the flash.  <Help>  This control 
        saves the customer configuration 
        on the module
        "
	  ::= { pmvoaCtrlconfMgnt1 10 }



pmvoaCtrlConf2Load1 OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Load Configuration Tables Set
         Nb 2 :When set this OID enables 
        loading from flash configuration2 
        into the PM.
        "
	  ::= { pmvoaCtrlconfMgnt1 2 }



pmvoaCtrlConf1Load1 OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Load Configuration Tables Set
         Nb 1 :When set this OID enables 
        loading from flash configuration1 
        into the PM.
        "
	  ::= { pmvoaCtrlconfMgnt1 1 }



--- *****************************************************
---     LEAF for the synth4 article
--- *****************************************************
pmvoaCtrlsynth4 OBJECT IDENTIFIER ::= { pmvoaCtrlOther 4 }




pmvoaCtrlCorrelatOff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Disable Alarm Correlation :This 
        OID disables the alarm correlation 
        in the PM.
        "
	  ::= { pmvoaCtrlsynth4 2 }



pmvoaCtrlCorrelatOn OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Enable Alarm Correlation :This 
        OID enables the alarm correlation 
        in the PM.
        "
	  ::= { pmvoaCtrlsynth4 1 }



--- *****************************************************
---     LEAF for the swMgnt article
--- *****************************************************
pmvoaCtrlswMgnt OBJECT IDENTIFIER ::= { pmvoaCtrlOther 5 }




pmvoaCtrlLoadSwBank2 OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Set Software Nb 2 As Active :This 
        OID, when set, loads the SW from 
        bank2 into the PM. It must be followed 
        by a reset.  <Help>  This controls 
        selects the second SW bank as the 
        active bank for the next module 
        reset
        "
	  ::= { pmvoaCtrlswMgnt 6 }



pmvoaCtrlLoadSwBank1 OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Set Software Nb 1 As Active :This 
        OID, when set, loads the SW from 
        bank1 into the PM. It must be followed 
        by a reset.  <Help>  This controls 
        selects the first SW bank as the 
        active bank for the next module 
        reset
        "
	  ::= { pmvoaCtrlswMgnt 5 }



pmvoaCtrlWarmReset OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        PM Warm Reset :This OID, when
         set, causes a warm reset of the 
        PM. This reset is not traffic affecting, 
        and the configuration of PM remains 
        unchanged.  <Help>  This control 
        initiates a warm reset of the module. 
        "
	  ::= { pmvoaCtrlswMgnt 3 }



pmvoaCtrlColdReset OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        PM Cold Reset :This OID, when
         set, causes a cold reset of the 
        PM. This reset is traffic affecting, 
        and the configuration of PM is
         reloaded on start-up.  <Help>
          This control initiates a cold 
        reset of the module. 
        "
	  ::= { pmvoaCtrlswMgnt 2 }



--- *****************************************************
---     LEAF for the gwMgnt article
--- *****************************************************
pmvoaCtrlgwMgnt OBJECT IDENTIFIER ::= { pmvoaCtrlOther 6 }




pmvoaCtrlLoadGwBank4 OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Set Gateware Nb 4 As Active :This 
        OID, when set, loads the GW from 
        bank4 (Flash) into the PM. It is 
        followed by an automatic gateware 
        cold reset.
        "
	  ::= { pmvoaCtrlgwMgnt 8 }



pmvoaCtrlLoadGwBank3 OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Set Gateware Nb 3 As Active :This 
        OID, when set, loads the GW from 
        bank3 (Flash) into the PM. It is 
        followed by an automatic gateware 
        cold reset.  <Help>  This controls 
        initiates a cold reset of the module 
        and select the third GW bank as 
        the active bank
        "
	  ::= { pmvoaCtrlgwMgnt 7 }



pmvoaCtrlLoadGwBank2 OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Set Gateware Nb 2 As Active :This 
        OID, when set, loads the GW from 
        bank2 (Flash) into the PM. It is 
        followed by an automatic gateware 
        cold reset.
        "
	  ::= { pmvoaCtrlgwMgnt 6 }



pmvoaCtrlLoadGwBank1 OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Set Gateware Nb 1 As Active :This 
        OID, when set, loads the GW from 
        bank1 (Flash) into the PM. It is 
        followed by an automatic gateware 
        cold reset.  <Help>  This controls 
        initiates a cold reset of the module 
        and select the first GW bank as 
        the active bank
        "
	  ::= { pmvoaCtrlgwMgnt 5 }



pmvoaCtrlCurrentGwReset OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Active Gateware Reset :This OID, 
        when set, resets the active gateware. 
        It is traffic affecting.
        "
	  ::= { pmvoaCtrlgwMgnt 1 }



--- *****************************************************
---     LEAF for the ledTest article
--- *****************************************************
pmvoaCtrlledTest OBJECT IDENTIFIER ::= { pmvoaCtrlOther 72 }




pmvoaCtrlLedOff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Leds Off :This OID switches off 
        all the Leds as a test feature. 
         <Help>  This control initiates 
        a test leds turning all the LEDs 
        to OFF
        "
	  ::= { pmvoaCtrlledTest 3 }



pmvoaCtrlRedLed OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Red Leds Test :This OID switches 
        on all the red Leds as a test feature. 
         <Help>  This control initiates 
        a test leds turning all the LEDs 
        to red
        "
	  ::= { pmvoaCtrlledTest 2 }



pmvoaCtrlGreenLed OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Green Leds Test :This OID switches 
        on all the green Leds as a test 
        feature.  <Help>  This control
         initiates a test leds turning
         all the LEDs to green
        "
	  ::= { pmvoaCtrlledTest 1 }








--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     MEASURES
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *********************************************************
---     TABLE for the pmvoaMesrlineSfpTemp articles
--- *********************************************************

pmvoaMesrlineSfpTempTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PmvoaMesrlineSfpTempEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pmvoaMesrlineSfpTemp Article
        "
	::= { pmvoaMesrLine 16 }


pmvoaMesrlineSfpTempEntry OBJECT-TYPE
	SYNTAX PmvoaMesrlineSfpTempEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pmvoaMesrlineSfpTemp 
        table
        "
	INDEX   { pmvoaMesrlineSfpTempIndex }
	::= { pmvoaMesrlineSfpTempTable 1 }


PmvoaMesrlineSfpTempEntry ::=
	SEQUENCE {
	pmvoaMesrlineSfpTempIndex
		INTEGER,
	pmvoaMesrlineSfpTempPortn
		INTEGER 
	}


pmvoaMesrlineSfpTempIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pmvoaMesrlineSfpTemp 
        table
        "
	::= { pmvoaMesrlineSfpTempEntry 1 }


pmvoaMesrlineSfpTempPortn OBJECT-TYPE
	SYNTAX  INTEGER (0..65535)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Temperature :This OID gives the 
        temperature value of the VOA SFP 
        (Temperature = AV_S16/256) (Unit 
        = C) <Help> This measure gives
         the temperature value of the VOA 
        SFP
        "
	::= { pmvoaMesrlineSfpTempEntry 2 }


--- *********************************************************
---     TABLE for the pmvoaMesrlinePout articles
--- *********************************************************

pmvoaMesrlinePoutTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PmvoaMesrlinePoutEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pmvoaMesrlinePout Article
        "
	::= { pmvoaMesrLine 48 }


pmvoaMesrlinePoutEntry OBJECT-TYPE
	SYNTAX PmvoaMesrlinePoutEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pmvoaMesrlinePout 
        table
        "
	INDEX   { pmvoaMesrlinePoutIndex }
	::= { pmvoaMesrlinePoutTable 1 }


PmvoaMesrlinePoutEntry ::=
	SEQUENCE {
	pmvoaMesrlinePoutIndex
		INTEGER,
	pmvoaMesrlinePoutPortn
		INTEGER 
	}


pmvoaMesrlinePoutIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pmvoaMesrlinePout 
        table
        "
	::= { pmvoaMesrlinePoutEntry 1 }


pmvoaMesrlinePoutPortn OBJECT-TYPE
	SYNTAX  INTEGER (0..65535)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Output Power :This OID gives the 
        output power value of the VOA SFP 
        (Power = 10*log(AV_U16)-40) (Unit 
        = dBm) <Help> This measure gives 
        the output power value of the VOA 
        SFP
        "
	::= { pmvoaMesrlinePoutEntry 2 }


--- *********************************************************
---     TABLE for the pmvoaMesrlineEstPin articles
--- *********************************************************

pmvoaMesrlineEstPinTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PmvoaMesrlineEstPinEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pmvoaMesrlineEstPin Article
        "
	::= { pmvoaMesrLine 64 }


pmvoaMesrlineEstPinEntry OBJECT-TYPE
	SYNTAX PmvoaMesrlineEstPinEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pmvoaMesrlineEstPin 
        table
        "
	INDEX   { pmvoaMesrlineEstPinIndex }
	::= { pmvoaMesrlineEstPinTable 1 }


PmvoaMesrlineEstPinEntry ::=
	SEQUENCE {
	pmvoaMesrlineEstPinIndex
		INTEGER,
	pmvoaMesrlineEstPinPortn
		INTEGER 
	}


pmvoaMesrlineEstPinIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pmvoaMesrlineEstPin 
        table
        "
	::= { pmvoaMesrlineEstPinEntry 1 }


pmvoaMesrlineEstPinPortn OBJECT-TYPE
	SYNTAX  INTEGER (0..65535)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Estimated Input Power :This OID 
        gives the estimated input power 
        value of the VOA SFP (Power = 10*log(AV_U16)-40) 
        (Unit = dBm) <Help> This measure 
        gives the estimated input power 
        value of the VOA SFP
        "
	::= { pmvoaMesrlineEstPinEntry 2 }







--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     DOWNLOAD
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the restartProcess article
--- *****************************************************
pmvoaDwlrestartProcess OBJECT IDENTIFIER ::= { pmvoaDwlOther 0 }




pmvoaDwlColdRestartProcessed OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Cold Restart :This OID indicates 
        that the module last restart was 
        a Cold RESTART
        "
	  ::= { pmvoaDwlrestartProcess 2 }



pmvoaDwlWarmRestartProcessed OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Warm Restart :This OID indicates 
        that the module last restart was 
        a Warm RESTART
        "
	  ::= { pmvoaDwlrestartProcess 1 }



--- *****************************************************
---     LEAF for the swBanksUsed article
--- *****************************************************
pmvoaDwlswBanksUsed OBJECT IDENTIFIER ::= { pmvoaDwlOther 1 }




pmvoaDwlSwBank2Notempty OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        SW bank 2 loaded :This OID indicates 
        a software is loaded in SW bank 
        2  <Help>  This status indicates 
        if the SW bank 2 contains SW package
        "
	  ::= { pmvoaDwlswBanksUsed 6 }



pmvoaDwlSwBank1Notempty OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        SW bank 1 loaded :This OID indicates 
        a software is loaded in SW bank 
        1  <Help>  This status indicates 
        if the SW bank 1 contains SW package
        "
	  ::= { pmvoaDwlswBanksUsed 5 }



pmvoaDwlSwBank2Used OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        SW bank 2 active :This OID indicates 
        the module is working on SW bank 
        2  <Help>  This status indicates 
        if the SW bank 2 is active or standby
        "
	  ::= { pmvoaDwlswBanksUsed 2 }



pmvoaDwlSwBank1Used OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        SW bank 1 active :This OID indicates 
        the module is working on SW bank 
        1  <Help>  This status indicates 
        if the SW bank 1 is active or standby
        "
	  ::= { pmvoaDwlswBanksUsed 1 }



--- *****************************************************
---     LEAF for the gwBanksUsed article
--- *****************************************************
pmvoaDwlgwBanksUsed OBJECT IDENTIFIER ::= { pmvoaDwlOther 2 }




pmvoaDwlGwBank4Notempty OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        GW bank 4 loaded :This OID indicates 
        a gateware is loaded in GW bank 
        4
        "
	  ::= { pmvoaDwlgwBanksUsed 8 }



pmvoaDwlGwBank3Notempty OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        GW bank 3 loaded :This OID indicates 
        a gateware is loaded in GW bank 
        3  <Help>  This status indicates 
        if the GW bank 3 contains GW package
        "
	  ::= { pmvoaDwlgwBanksUsed 7 }



pmvoaDwlGwBank2Notempty OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        GW bank 2 loaded :This OID indicates 
        a gateware is loaded in GW bank 
        2
        "
	  ::= { pmvoaDwlgwBanksUsed 6 }



pmvoaDwlGwBank1Notempty OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        GW bank 1 loaded :This OID indicates 
        a gateware is loaded in GW bank 
        1  <Help>  This status indicates 
        if the GW bank 1 contains GW package
        "
	  ::= { pmvoaDwlgwBanksUsed 5 }



pmvoaDwlGwBank4Used OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        GW bank 4 active :This OID indicates 
        the module is working on GW bank 
        4
        "
	  ::= { pmvoaDwlgwBanksUsed 4 }



pmvoaDwlGwBank3Used OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        GW bank 3 active :This OID indicates 
        the module is working on GW bank 
        3  <Help>  This status indicates 
        if the GW bank 3 is active or standby
        "
	  ::= { pmvoaDwlgwBanksUsed 3 }



pmvoaDwlGwBank2Used OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        GW bank 2 active :This OID indicates 
        the module is working on GW bank 
        2
        "
	  ::= { pmvoaDwlgwBanksUsed 2 }



pmvoaDwlGwBank1Used OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        GW bank 1 active :This OID indicates 
        the module is working on GW bank 
        1  <Help>  This status indicates 
        if the GW bank 1 is active or standby
        "
	  ::= { pmvoaDwlgwBanksUsed 1 }








--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     CONFIG
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the table Group startup
--- *****************************************************

pmvoaCfgStartup OBJECT IDENTIFIER ::= { pmvoaConfig 1 }



--- *****************************************************
---     LEAF for the table 2190
--- *****************************************************

pmvoaCfgLinexr1StartupTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PmvoaCfgLinexr1StartupEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pmvoaCfgStartup 1 }


pmvoaCfgLinexr1StartupEntry OBJECT-TYPE
	SYNTAX PmvoaCfgLinexr1StartupEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the startup 
        table
        "
	INDEX   { pmvoaCfgLinexr1StartupIndex }
	::= { pmvoaCfgLinexr1StartupTable 1 }


PmvoaCfgLinexr1StartupEntry ::=
	SEQUENCE {
	pmvoaCfgLinexr1StartupIndex
		INTEGER,
	pmvoaCfgSfpModePortn
		Unsigned32,
	pmvoaCfgAttenuationCtrlPortn
		Unsigned32,
	pmvoaCfgPowerCtrlPortn
		Unsigned32,
	pmvoaCfgLosInputThresholdPortn
		Unsigned32,
	pmvoaCfgInsertionLossValuePortn
		Unsigned32
	}


pmvoaCfgLinexr1StartupIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the linexr1Startup 
        table
        "
	::= { pmvoaCfgLinexr1StartupEntry 1 }


pmvoaCfgSfpModePortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default mode on the SFP :This
          register configures the default 
        initialisation settings on the
         SFP
        "
	::= { pmvoaCfgLinexr1StartupEntry 3 }


pmvoaCfgAttenuationCtrlPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default attenuation setting on 
        the SFP :This  register configures 
        the default initialisation settings 
        of the attenuation
        "
	::= { pmvoaCfgLinexr1StartupEntry 4 }


pmvoaCfgPowerCtrlPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default power setting on the SFP 
        :This  register configures the
         default initialisation settings 
        of the power
        "
	::= { pmvoaCfgLinexr1StartupEntry 5 }


pmvoaCfgLosInputThresholdPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default threshold setting on the 
        SFP :This  register configures
         the default initialisation settings 
        of the input threshold
        "
	::= { pmvoaCfgLinexr1StartupEntry 6 }


pmvoaCfgInsertionLossValuePortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default Insertion Loss setting 
        on the SFP :This  register configures 
        the default initialisation settings 
        of the insertion loss value
        "
	::= { pmvoaCfgLinexr1StartupEntry 7 }


--- *****************************************************
---     LEAF for the table Group labels
--- *****************************************************

pmvoaCfgLabels OBJECT IDENTIFIER ::= { pmvoaConfig 2 }



--- *****************************************************
---     LEAF for the table 0003
--- *****************************************************

pmvoaCfgLabelclientTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PmvoaCfgLabelclientEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pmvoaCfgLabels 1 }


pmvoaCfgLabelclientEntry OBJECT-TYPE
	SYNTAX PmvoaCfgLabelclientEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the labels
         table
        "
	INDEX   { pmvoaCfgLabelclientIndex }
	::= { pmvoaCfgLabelclientTable 1 }


PmvoaCfgLabelclientEntry ::=
	SEQUENCE {
	pmvoaCfgLabelclientIndex
		INTEGER,
	pmvoaCfgLabelclientPortn
		DisplayString
	}


pmvoaCfgLabelclientIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the labelclient 
        table
        "
	::= { pmvoaCfgLabelclientEntry 1 }


pmvoaCfgLabelclientPortn OBJECT-TYPE
	SYNTAX  DisplayString( SIZE(1..16))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default settings on the label
         of the Ports :These registers
         configures the default initialisation 
        settings of the labels of the ports.
        "
	::= { pmvoaCfgLabelclientEntry 3 }


--- *****************************************************
---     LEAF for the table 0004
--- *****************************************************

pmvoaCfgLabellineTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PmvoaCfgLabellineEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pmvoaCfgLabels 2 }


pmvoaCfgLabellineEntry OBJECT-TYPE
	SYNTAX PmvoaCfgLabellineEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the labels
         table
        "
	INDEX   { pmvoaCfgLabellineIndex }
	::= { pmvoaCfgLabellineTable 1 }


PmvoaCfgLabellineEntry ::=
	SEQUENCE {
	pmvoaCfgLabellineIndex
		INTEGER,
	pmvoaCfgLabellinePortn
		DisplayString
	}


pmvoaCfgLabellineIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the labelline 
        table
        "
	::= { pmvoaCfgLabellineEntry 1 }


pmvoaCfgLabellinePortn OBJECT-TYPE
	SYNTAX  DisplayString( SIZE(1..16))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default settings on the label
         of the lines :These registers
         configures the default initialisation 
        settings of the labels of the lines.
        "
	::= { pmvoaCfgLabellineEntry 3 }



pmvoaCfgWriteConfiguration  OBJECT-TYPE
	SYNTAX EkiOnOff
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
	"Write configuration to module:This OID 
	 writes the complete configuration to the module"
	::= { pmvoaConfig 257 }






--- *****************************************************
---     TRAP OBJECTS
--- *****************************************************

pmvoatrapPortNumber OBJECT-TYPE
	SYNTAX INTEGER(1..64)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
	"Last port which generates a trap"
	::= { pmvoatraps 2 }

pmvoatrapLineNumber OBJECT-TYPE
	SYNTAX INTEGER(1..64)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
	"Last Line which generates a trap"
	::= { pmvoatraps 3 }

pmvoatrapBoardNumber OBJECT-TYPE
	SYNTAX INTEGER(1..64)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
	"Last module which generates a trap"
	::= { pmvoatraps 4 }







--- *****************************************************
---     LINE TRAPS
--- *****************************************************

pmvoaLineTrapCritGoesOn NOTIFICATION-TYPE
	OBJECTS {pmvoaAlmLineFailPortn , pmvoaAlmLineHwFailPortn , pmvoatrapLineNumber, pmvoatrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMVOA Line Fail ON"
	--&ACTIONS     { log, critical }
	--&MATCH       { pmvoaAlmLineFailPortn "on", pmvoaAlmLineHwFailPortn "*", pmvoatrapLineNumber "$3", pmvoatrapBoardNumber "$4"}
	--&MESG        "Line Port $3 Down on PMVOA in Slot $4 ($A)"
	
	--&FILTNAME    "PMVOA Line HW Fail ON (Hidden)"
	--&ACTIONS     { info }
	--&MATCH       { pmvoaAlmLineFailPortn "*", pmvoaAlmLineHwFailPortn "on", pmvoatrapLineNumber "$3", pmvoatrapBoardNumber "$4"}
	--&MESG        "Line Port $3 Down on PMVOA in Slot $4 ($A)"
	DESCRIPTION "Critical Line default is activated"
	::= { pmvoatraps 34 }

pmvoaLineTrapCritGoesOff NOTIFICATION-TYPE
	OBJECTS {pmvoaAlmLineFailPortn , pmvoaAlmLineHwFailPortn , pmvoatrapLineNumber, pmvoatrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMVOA Line Fail OFF"
	--&ACTIONS     { log,  normal }
	--&CLEARS      { "PMVOA Line Fail ON" }
	--&MATCH       { pmvoaAlmLineFailPortn "on", pmvoaAlmLineHwFailPortn "*", pmvoatrapLineNumber "$3", pmvoatrapBoardNumber "$4"}
	--&MESG        "Line Port $3 Up on PMVOA in Slot $4 ($A)"

	--&FILTNAME    "PMVOA Line HW Fail OFF (Hidden)"
	--&ACTIONS     { info }
	--&MATCH       { pmvoaAlmLineFailPortn "*", pmvoaAlmLineHwFailPortn "on", pmvoatrapLineNumber "$3", pmvoatrapBoardNumber "$4"}
	--&MESG        "Line Port $3 Up on PMVOA in Slot $4 ($A)"
	DESCRIPTION "Critical Line default disappeared"
	::= { pmvoatraps 35 }






--- *****************************************************
---     CLIENT TRAPS
--- *****************************************************






--- *****************************************************
---     HW TRAPS
--- *****************************************************

pmvoaPowerTrapUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pmvoaAlmDefFuseB, pmvoaAlmDefFuseA , pmvoatrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMVOA Fuse A Fail ON"
	--&ACTIONS     { log, major }
	--&MATCH       { pmvoaAlmDefFuseB "*", pmvoaAlmDefFuseA "on", pmvoatrapBoardNumber "$3"}
	--&MESG        "Power Input A Fail on PMVOA in Slot $3 ($A)"

	--&FILTNAME    "PMVOA Fuse B Fail ON"
	--&ACTIONS     { log, major }
	--&MATCH       { pmvoaAlmDefFuseB "on", pmvoaAlmDefFuseA "*", pmvoatrapBoardNumber "$3"}
	--&MESG        "Power Input B Fail on PMVOA in Slot $3 ($A)"
	DESCRIPTION "Urgent power supply default is activated"
	::= { pmvoatraps 50 }

pmvoaPowerTrapUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pmvoaAlmDefFuseB, pmvoaAlmDefFuseA , pmvoatrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMVOA Fuse A&B Fail OFF"
	--&ACTIONS     { log, normal}
	--&CLEARS      { "PMVOA Fuse A Fail ON", "PMVOA Fuse B Fail ON" }
	--&MATCH       { pmvoaAlmDefFuseB "on", pmvoaAlmDefFuseA "on", pmvoatrapBoardNumber "$3"}
	--&MESG        "Power Inputs A and B Present on PMVOA in Slot $3 ($A)"
	
	DESCRIPTION "Urgent power supply default disappeared"
	::= { pmvoatraps 51 }






END