-- EKINOPS-pmoabphcs.TXT:  MIB
--
--MIB Part Number:3MI00211AAAC
--MIB Version:01
--
-- Copyright (c) 2016 by Ekinops
-- All rights reserved.
-- 
-- *****************************************************************

EKINOPS-Pmoabphcs-MIB DEFINITIONS ::= BEGIN

IMPORTS
	ekinops,
	EkiState,
	EkiOnOff,
	EkiMode,
	EkiProtocol,
	EkiApiState,
	EkiSynchroMode,
	EkiMeasureType
			FROM EKINOPS-MIB
        MODULE-IDENTITY,
        OBJECT-TYPE,
        NOTIFICATION-TYPE,
	Unsigned32,
	Integer32,
	Counter32,
	IpAddress                
        		FROM SNMPv2-SMI
 	TEXTUAL-CONVENTION,
	DisplayString
                FROM SNMPv2-TC;

modulepmoabphcs MODULE-IDENTITY
        LAST-UPDATED "201605230000Z"
        ORGANIZATION "Ekinops"
        CONTACT-INFO
         "Ekinops

          3, rue Blaise Pascal
          F-22300 Lannion / FRANCE

          Tel : +33 (0)2 96 05 00 30
          Fax : +33 (0)2 96 48 62 39

          E-mail: support@ekinops.net"
        DESCRIPTION
          "Creation"
	REVISION "201403100000Z"
	DESCRIPTION
	  "Initial Version."

	REVISION "201403100000Z"
	DESCRIPTION
	  "Creation"
	REVISION "201501270000Z"
	DESCRIPTION
	  "Labels cosmetic updates"
	REVISION "201605230000Z"
	DESCRIPTION
	  "New AlarmType  synthesisAlarm (12)"
        ::= { ekinops 61 }



--- *****************************************************
---     LEAF LEVEL 2
--- *****************************************************


pmoabphcsalarms OBJECT IDENTIFIER ::= { modulepmoabphcs 2 }	
pmoabphcsAlmOther OBJECT IDENTIFIER ::= { pmoabphcsalarms 1 }
pmoabphcsAlmOtherNurg OBJECT IDENTIFIER ::= { pmoabphcsAlmOther 1 }
pmoabphcsAlmOtherUrg OBJECT IDENTIFIER ::= { pmoabphcsAlmOther 2 }
pmoabphcsAlmOtherCrit OBJECT IDENTIFIER ::= { pmoabphcsAlmOther 3 }

pmoabphcsAlmClient OBJECT IDENTIFIER ::= { pmoabphcsalarms 2 }
pmoabphcsAlmClientNurg OBJECT IDENTIFIER ::= { pmoabphcsAlmClient 1 }
pmoabphcsAlmClientUrg OBJECT IDENTIFIER ::= { pmoabphcsAlmClient 2 }
pmoabphcsAlmClientCrit OBJECT IDENTIFIER ::= { pmoabphcsAlmClient 3 }
	
pmoabphcsAlmLine OBJECT IDENTIFIER ::= { pmoabphcsalarms 3 }
pmoabphcsAlmLineNurg OBJECT IDENTIFIER ::= { pmoabphcsAlmLine 1 }
pmoabphcsAlmLineUrg OBJECT IDENTIFIER ::= { pmoabphcsAlmLine 2 }
pmoabphcsAlmLineCrit OBJECT IDENTIFIER ::= { pmoabphcsAlmLine 3 }

pmoabphcsmeasures OBJECT IDENTIFIER ::= { modulepmoabphcs 3 }	
pmoabphcsMesrOther OBJECT IDENTIFIER ::= { pmoabphcsmeasures 1 }	
pmoabphcsMesrClient OBJECT IDENTIFIER ::= { pmoabphcsmeasures 2 }	
pmoabphcsMesrLine OBJECT IDENTIFIER ::= { pmoabphcsmeasures 3 }	

pmoabphcscounters OBJECT IDENTIFIER ::= { modulepmoabphcs 4 }
pmoabphcsCntOther OBJECT IDENTIFIER ::= { pmoabphcscounters 1 }
pmoabphcsCntClient OBJECT IDENTIFIER ::= { pmoabphcscounters 2 }
pmoabphcsCntLine OBJECT IDENTIFIER ::= { pmoabphcscounters 3 }

pmoabphcscontrolsWrite OBJECT IDENTIFIER ::= { modulepmoabphcs 6 }
pmoabphcsCtrlOther OBJECT IDENTIFIER ::= { pmoabphcscontrolsWrite 1 }
pmoabphcsCtrlClient OBJECT IDENTIFIER ::= { pmoabphcscontrolsWrite 2 }
pmoabphcsCtrlLine OBJECT IDENTIFIER ::= { pmoabphcscontrolsWrite 3 }

pmoabphcsri OBJECT IDENTIFIER ::= { modulepmoabphcs 7 }


pmoabphcsConfig OBJECT IDENTIFIER ::= { modulepmoabphcs 9 }

pmoabphcstraps OBJECT IDENTIFIER ::= { modulepmoabphcs 10 }


--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     TEXTUAL-CONVENTION
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************


PmoabphcspreampMode ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION "Different modes on OA preamp"
    SYNTAX INTEGER {
		oabphcspreampdefaultmode(0),
		oabphcspreampconstantcurrentmode(1),
		oabphcspreampconstantpowermode(2)
		oabphcspreampconstantgainmode(3)
		oabphcspreamppoutpinmode(4)
		oabphcspreampmanualmode(5)
		oabphcspreampfeedforwardmode(6)
		oabphcspreamptransientsupmode(7)

           }

PmoabphcsboosterMode ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION "Different modes on OA booster"
    SYNTAX INTEGER {
		oabphcsboosterdefaultmode(0),
		oabphcsboosterconstantcurrentmode(1),
		oabphcsboosterconstantpowermode(2)
		oabphcsboosterconstantgainmode(3)
		oabphcsboosterpoutpinmode(4)
		oabphcsboostermanualmode(5)
		oabphcsboosterfeedforwardmode(6)
		oabphcsboostertransientsupmode(7)
           }


PmoabphcsaprMode ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION "Different modes on APR"
    SYNTAX INTEGER {
		oabphcsaproffmode(0),
		oabphcsaprsemiautomode(1),
		oabphcsaprautomode(2)
		oabphcsaprlossforwardingmode(3)
		oabphcsaprrepeatmode(4)

           }

PmoabphcsPreampGainAdjMode ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION "Different modes on Gain"
    SYNTAX INTEGER {
		oabphcspreampgainadjmanualmode(0),
		oabphcspreampgainadjsemiautomode(1),
		oabphcspreampgainadjautomode(2)

           }

PmoabphcsBoosterGainAdjMode ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION "Different modes on Gain"
    SYNTAX INTEGER {
		oabphcsboostergainadjmanualmode(0),
		oabphcsboostergainadjsemiautomode(1),
		oabphcsboostergainadjautomode(2)

           }

PmoabphcsPreampCstGainAdjMode ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION "Different modes when constant Gain"
    SYNTAX INTEGER {
		oabphcspreampcstgainadjsemiautomode(1),
		oabphcspreampcstgainadjautomode(2)

           }

PmoabphcsBoosterCstGainAdjMode ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION "Different modes when constant Gain"
    SYNTAX INTEGER {
		oabphcsboostercstgainadjsemiautomode(1),
		oabphcsboostercstgainadjautomode(2)

           }


--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     REMOTE INVENTORY
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************

pmoabphcsRinvReloadInventory OBJECT-TYPE
  SYNTAX EkiOnOff
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
        "Reload the inventory: This OID triggers an 
         inventory reload."
  ::= { pmoabphcsri 2 }
  
pmoabphcsRinvHwPlatform OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
        "HW platform description: This OID contains the 
         description of the Hardware platform."
  ::= { pmoabphcsri 3 }

pmoabphcsRinvModulePlatform OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
        "Module platform description: This OID contains the 
         description of the Module."
  ::= { pmoabphcsri 4 }
  
pmoabphcsRinvSwPlatform OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
        "SW platform description: This OID contains the 
         description of the Software platform."
  ::= { pmoabphcsri 5 }

pmoabphcsRinvGwPlatform OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
        "GW platform description: This OID contains the 
         description of the gateware platform."
  ::= { pmoabphcsri 6 }
  
  
pmoabphcsRinvBoosterTable OBJECT-TYPE
      SYNTAX  SEQUENCE OF PmoabphcsRinvBoosterEntry
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
              "List of the Boosters on the selected module"
      ::= { pmoabphcsri 7 }

pmoabphcsRinvBoosterEntry OBJECT-TYPE
        SYNTAX  PmoabphcsRinvBoosterEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
              "Row definition for the Boosters table"
        INDEX   { pmoabphcsRinvBoosterIndex }
        ::= { pmoabphcsRinvBoosterTable 1 }
    


PmoabphcsRinvBoosterEntry::=
        SEQUENCE {
          pmoabphcsRinvBoosterIndex 
              Integer32,
          pmoabphcsRinvBooster
              DisplayString
        }


    pmoabphcsRinvBoosterIndex OBJECT-TYPE
        SYNTAX  Integer32(1..16)
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
              "Index for Booster table"
        ::= { pmoabphcsRinvBoosterEntry 1 }


    pmoabphcsRinvBooster OBJECT-TYPE
        SYNTAX  DisplayString
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
              "Inventory for the Booster: This OID contains the inventory for the Booster"
        ::= { pmoabphcsRinvBoosterEntry 2 }




pmoabphcsRinvPreAmpTable OBJECT-TYPE
      SYNTAX  SEQUENCE OF PmoabphcsRinvPreAmpEntry
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
              "List of the PreAmps on the selected module"
      ::= { pmoabphcsri 8 }

pmoabphcsRinvPreAmpEntry OBJECT-TYPE
        SYNTAX  PmoabphcsRinvPreAmpEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
              "Row definition for the PreAmp table"
        INDEX   { pmoabphcsRinvPreAmpIndex }
        ::= { pmoabphcsRinvPreAmpTable 1 }
    


PmoabphcsRinvPreAmpEntry::=
        SEQUENCE {
          pmoabphcsRinvPreAmpIndex 
              Integer32,
          pmoabphcsRinvPreAmp
              DisplayString
        }


    pmoabphcsRinvPreAmpIndex OBJECT-TYPE
        SYNTAX  Integer32(1..16)
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
              "Index for PreAmp table"
        ::= { pmoabphcsRinvPreAmpEntry 1 }


    pmoabphcsRinvPreAmp OBJECT-TYPE
        SYNTAX  DisplayString
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
              "Inventory for the PreAmp: This OID contains the inventory for the PreAmp"
        ::= { pmoabphcsRinvPreAmpEntry 2 }



  




--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     ALARMS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the synthAlm0 article
--- *****************************************************
pmoabphcsAlmsynthAlm0 OBJECT IDENTIFIER ::= { pmoabphcsAlmOtherCrit 0 }




pmoabphcsAlmDefFuseB OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Fuse B Fail :This OID indicates 
        that the fuse of the power input 
        B is in fail condition  <Help>
          Status of the Fuse B <Condtype> 
        DEF_FUSE_B <Probcause> powerProblem 
        (36) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmsynthAlm0 16 }



pmoabphcsAlmDefFuseA OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Fuse A Fail :This OID indicates 
        that the fuse of the power input 
        A is in fail condition  <Help>
          Status of the Fuse A <Condtype> 
        DEF_FUSE_A <Probcause> powerProblem 
        (36) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmsynthAlm0 15 }



pmoabphcsAlmExtPump1NotLocked OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        External Pump Not Detected :This 
        OID indicates that the first external 
        pump is not detected by the amplifier 
        module  <Help>  This alarm indicates 
        if the external pump is detected 
        by the amplifier module <Condtype> 
        EXT_PUMP1_NOT_LOCKED <Probcause> 
        pumpFailure (39) <Alarmtype> equipmentAlarm 
        (5)  <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmsynthAlm0 12 }



pmoabphcsAlmDwEdfaInitNotCompl OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Not Initialized :This
         OID indicates that the initialisation 
        of the Pre-Amp is not completed 
         <Help>  This status indicates
         if the Pre-Amp has been correctly 
        initialized <Condtype> DW_EDFA_INIT_NOT_COMPL 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> equipmentAlarm 
        (5)  <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmsynthAlm0 11 }



pmoabphcsAlmUpEdfaInitNotCompl OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Not Initialized :This
         OID indicates that the initialisation 
        of the Booster is not completed 
         <Help>  This status indicates
         if the Booster has been correctly 
        initialized <Condtype> UP_EDFA_INIT_NOT_COMPL 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> equipmentAlarm 
        (5)  <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmsynthAlm0 10 }



pmoabphcsAlmModGlobFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Module Failure :This OID is set 
        on detection of a failure originating 
        from the PM <Condtype> MOD_GLOB_FAIL 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmsynthAlm0 9 }



pmoabphcsAlmAprOn OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Automatic Power Reduction :This 
        OID indicates that the APR algorithm 
        has been operated and the  output 
        of the lasers are shutdown  <Help> 
          The APR algorithm has been completed 
         <Condtype> APR_ON <Probcause>
         other (1) <Alarmtype> other (1) 
        <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmsynthAlm0 2 }



pmoabphcsAlmMaintenanceMode OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Maintenance Mode :This OID indicates 
        that the PM is in maintenance mode 
         <Help>  This status indiates if 
        the module is currently in maintenance 
        mode <Condtype> MAINTENANCE_MODE 
        <Probcause> other (1) <Alarmtype> 
        other (1) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmsynthAlm0 1 }



--- *****************************************************
---     LEAF for the synthAlm2 article
--- *****************************************************
pmoabphcsAlmsynthAlm2 OBJECT IDENTIFIER ::= { pmoabphcsAlmOtherNurg 2 }




pmoabphcsAlmConfTableLoad OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        PM Configuration Load :This OID 
         is at 1 during the loading of
         configuration tables in the modules 
        RAM. <Condtype> CONF_TABLE_LOAD 
        <Probcause> other (1) <Alarmtype> 
        other (1) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmsynthAlm2 3 }



pmoabphcsAlmInvUpload OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Inventory Upload :This OID is
         at 1 during the uploading of PM 
        inventory information. <Condtype> 
        INV_UPLOAD <Probcause> other (1) 
        <Alarmtype> other (1) <Polarity> 
        (2) 
        "
	  ::= { pmoabphcsAlmsynthAlm2 2 }



pmoabphcsAlmConfTableSave OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        PM Configuration Save :This OID 
        is at 1 during the saving of a
         new configuration table in the 
        module Flash memory. <Condtype> 
        CONF_TABLE_SAVE <Probcause> other 
        (1) <Alarmtype> other (1) <Polarity> 
        (2) 
        "
	  ::= { pmoabphcsAlmsynthAlm2 1 }



--- *****************************************************
---     LEAF for the synthAlm7 article
--- *****************************************************
pmoabphcsAlmsynthAlm7 OBJECT IDENTIFIER ::= { pmoabphcsAlmLineCrit 7 }




pmoabphcsAlmSupvaFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
         : <Condtype> SUPVA_FAIL <Probcause> 
        equipmentMalfunction (16) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmsynthAlm7 14 }



pmoabphcsAlmLineExtPumpFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster External Pump Fail :This 
        OID indicates that the external 
        pump linked to the Booster is in 
        fail condition   <Help>  This alarm 
        indicates if the external pump
         linked to the Booster is in fail 
        condition <Condtype> LINE_EXT_PUMP_FAIL 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmsynthAlm7 13 }



pmoabphcsAlmLineFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line Port Failure :This OID indicates 
        a failure on the line port <Condtype> 
        LINE_FAIL <Probcause> callEstablishmentError(5) 
        <Alarmtype> synthesisAlarm (12) 
         <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmsynthAlm7 12 }



pmoabphcsAlmLineTxOff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Optical Output Shutdown 
        :This OID indicates the Booster 
        optical output power is on  <Help> 
         This status indicates if the Booster 
        laser pump is ON or OFF <Condtype> 
        LINE_TX_OFF <Probcause> other (1) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmsynthAlm7 5 }



pmoabphcsAlmLineHwFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line Port HW Failure :This OID 
        indicates a failure on line port, 
        most probably caused by a HW issue 
        <Condtype> LINE_HW_FAIL <Probcause> 
        equipmentMalfunction (16) <Alarmtype> 
        synthesisAlarm (12)  <Polarity> 
        (2) 
        "
	  ::= { pmoabphcsAlmsynthAlm7 4 }



--- *****************************************************
---     LEAF for the synthAlm8 article
--- *****************************************************
pmoabphcsAlmsynthAlm8 OBJECT IDENTIFIER ::= { pmoabphcsAlmClientCrit 8 }




pmoabphcsAlmSupvbFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
         : <Condtype> SUPVB_FAIL <Probcause> 
        equipmentMalfunction (16) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmsynthAlm8 14 }



pmoabphcsAlmClientExtPumpFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp External Pump Fail :This 
        OID indicates that the external 
        pump linked to the Pre-Amp is in 
        fail condition   <Help>  This alarm 
        indicates if the external pump
         linked to the Pre-Amp is in fail 
        condition <Condtype> CLIENT_EXT_PUMP_FAIL 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmsynthAlm8 13 }



pmoabphcsAlmClientFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Client Port Failure :This OID
         indicates a failure on the Client 
        port <Condtype> CLIENT_FAIL <Probcause> 
        bandwidthReduced(4) <Alarmtype> 
        synthesisAlarm (12)  <Polarity> 
        (2) 
        "
	  ::= { pmoabphcsAlmsynthAlm8 12 }



pmoabphcsAlmClientTxOff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Optical Output Shutdown 
        :This OID indicates the Pre-Amp 
        optical output power is on  <Help> 
         This status indicates if the Pre-Amp 
        laser pump transceiver laser is 
        ON or OFF <Condtype> CLIENT_TX_OFF 
        <Probcause> other (1) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmsynthAlm8 5 }



pmoabphcsAlmClientHwFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Client Port HW Failure :This OID 
        indicates a failure on Client port, 
        most probably caused by a HW issue 
        <Condtype> CLIENT_HW_FAIL <Probcause> 
        equipmentMalfunction (16) <Alarmtype> 
        synthesisAlarm (12)  <Polarity> 
        (2) 
        "
	  ::= { pmoabphcsAlmsynthAlm8 4 }



--- *****************************************************
---     LEAF for the clientEdfaAlarms1 article
--- *****************************************************
pmoabphcsAlmclientEdfaAlarms1 OBJECT IDENTIFIER ::= { pmoabphcsAlmClientUrg 32 }




pmoabphcsAlmClientBiasHighAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Bias High Alarm :This
         OID indicates that the Bias is 
        higher than the alarm threshold 
        of the Pre-Amp Optical Module 
         <Help>  This alarm indicates if 
        the Pre-Amp bias is too high <Condtype> 
        CLIENT_BIAS_HIGH_ALARM <Probcause> 
        pumpFailure (39) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmclientEdfaAlarms1 8 }



pmoabphcsAlmClientBiasLowAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Bias Low Alarm :This OID 
        indicates that the Bias is lower 
        than the alarm threshold of the 
        Pre-Amp Optical Module  <Help>
          This alarm indicates if the Pre-Amp 
        bias is too low <Condtype> CLIENT_BIAS_LOW_ALARM 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmclientEdfaAlarms1 7 }



pmoabphcsAlmClientOutputPwrHighAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Tx Pwr High Alarm :This 
        OID indicates that the Transmit 
        Power is higher than the alarm
         threshold of the Pre-Amp Optical 
        Module  <Help>  This alarm indicates 
        if the Pre-Amp tx power is too
         high <Condtype> CLIENT_OUTPUT_PWR_HIGH_ALARM 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmclientEdfaAlarms1 6 }



pmoabphcsAlmClientOutputPwrLowAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Tx Pwr Low Alarm :This 
        OID indicates that the Transmit 
        Power is lower than the alarm threshold 
        of the Pre-Amp Optical Module 
         <Help>  This alarm indicates if 
        the Pre-Amp tx power is too low 
        <Condtype> CLIENT_OUTPUT_PWR_LOW_ALARM 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmclientEdfaAlarms1 5 }



pmoabphcsAlmClientInputPwrHighAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Rx Pwr High Alarm :This 
        OID indicates that the Receive
         Power is higher than the alarm 
        threshold of the Pre-Amp Optical 
        Module  <Help>  This alarm indicates 
        if the Pre-Amp rx power is too
         high <Condtype> CLIENT_INPUT_PWR_HIGH_ALARM 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmclientEdfaAlarms1 4 }



pmoabphcsAlmClientInputPwrLowAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Rx Pwr Low Alarm :This 
        OID indicates that the Receive
         Power is lower than the alarm
         threshold of the Pre-Amp Optical 
        Module  <Help>  This alarm indicates 
        if the Pre-Amp rx power is too
         low <Condtype> CLIENT_INPUT_PWR_LOW_ALARM 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmclientEdfaAlarms1 3 }



pmoabphcsAlmClientGainHighAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Gain High Alarm :This
         OID indicates that the Gain is 
        higher than the alarm threshold 
        of the Pre-Amp Module  <Help> 
         This alarm indicates if the Pre-Amp 
        gain is too high <Condtype> CLIENT_GAIN_HIGH_ALARM 
        <Probcause> performanceDegraded 
        (35) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmclientEdfaAlarms1 2 }



pmoabphcsAlmClientGainLowAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Gain Low Alarm :This OID 
        indicates that the Gain is lower 
        than the alarm threshold of the 
        Pre-Amp Module  <Help>  This alarm 
        indicates if the Pre-Amp gain is 
        too low <Condtype> CLIENT_GAIN_LOW_ALARM 
        <Probcause> performanceDegraded 
        (35) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmclientEdfaAlarms1 1 }



--- *****************************************************
---     LEAF for the clientEdfaWarnings article
--- *****************************************************
pmoabphcsAlmclientEdfaWarnings OBJECT IDENTIFIER ::= { pmoabphcsAlmClientNurg 33 }




pmoabphcsAlmClientBiasHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Bias High Warning :This 
        OID indicates that the Bias is
         higher than the Warning threshold 
        of the Pre-Amp Optical Module 
         <Help>  This warning indicates 
        if the Pre-Amp bias is too high 
        <Condtype> CLIENT_BIAS_HIGH_WARNING 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmclientEdfaWarnings 8 }



pmoabphcsAlmClientBiasLowWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Bias Low Warning :This 
        OID indicates that the Bias is
         lower than the Warning threshold 
        of the Pre-Amp Optical Module 
         <Help>  This warning indicates 
        if the Pre-Amp bias is too low
         <Condtype> CLIENT_BIAS_LOW_WARNING 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmclientEdfaWarnings 7 }



pmoabphcsAlmClientOutputPwrHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Tx Pwr High Warning :This 
        OID indicates that the Transmit 
        Power is higher than the Warning 
        threshold of the Pre-Amp Optical 
        Module  <Help>  This warning indicates 
        if the Pre-Amp tx power is too
         high <Condtype> CLIENT_OUTPUT_PWR_HIGH_WARNING 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmclientEdfaWarnings 6 }



pmoabphcsAlmClientOutputPwrLowWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Tx Pwr Low Warning :This 
        OID indicates that the Transmit 
        Power is lower than the Warning 
        threshold of the Pre-Amp Optical 
        Module  <Help>  This warning indicates 
        if the Pre-Amp tx power is too
         low <Condtype> CLIENT_OUTPUT_PWR_LOW_WARNING 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmclientEdfaWarnings 5 }



pmoabphcsAlmClientInputPwrHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Rx Pwr High Warning :This 
        OID indicates that the Receive
         Power is higher than the Warning 
        threshold of the Pre-Amp Optical 
        Module  <Help>  This warning indicates 
        if the Pre-Amp rx power is too
         high <Condtype> CLIENT_INPUT_PWR_HIGH_WARNING 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmclientEdfaWarnings 4 }



pmoabphcsAlmClientInputPwrLowWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Rx Pwr Low Warning :This 
        OID indicates that the Receive
         Power is lower than the Warning 
        threshold of the Pre-Amp Optical 
        Module  <Help>  This warning indicates 
        if the Pre-Amp rx power is too
         low <Condtype> CLIENT_INPUT_PWR_LOW_WARNING 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmclientEdfaWarnings 3 }



pmoabphcsAlmClientGainHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Gain High Warning :This 
        OID indicates that the Gain is
         higher than the Warning threshold 
        of the Pre-Amp Module  <Help> 
         This alarm indicates if the Pre-Amp 
        gain is too high <Condtype> CLIENT_GAIN_HIGH_WARNING 
        <Probcause> performanceDegraded 
        (35) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmclientEdfaWarnings 2 }



pmoabphcsAlmClientGainLowWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Gain Low Warning :This 
        OID indicates that the Gain is
         lower than the Warning threshold 
        of the Pre-Amp Module  <Help> 
         This alarm indicates if the Pre-Amp 
        gain is too low <Condtype> CLIENT_GAIN_LOW_WARNING 
        <Probcause> performanceDegraded 
        (35) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmclientEdfaWarnings 1 }



--- *****************************************************
---     LEAF for the clientEdfaAlarms2 article
--- *****************************************************
pmoabphcsAlmclientEdfaAlarms2 OBJECT IDENTIFIER ::= { pmoabphcsAlmClientCrit 35 }




pmoabphcsAlmClientGainOutOfRange OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Gain Out Of Range :This 
        OID indicates the target gain of 
        the Pre-Amp is out of range (18-32dB), 
        the flatness of the Booster is
         not guaranteed.<Help> This alarm 
        indicates the target gain of the 
        Pre-Amp is out of range (18-32dB), 
        the flatness of the Booster is
         not guaranteed. <Condtype> CLIENT_GAIN_OUT_OF_RANGE 
        <Probcause> other (1) <Alarmtype> 
        equipmentAlarm (5)  <Polarity>
         (2) 
        "
	  ::= { pmoabphcsAlmclientEdfaAlarms2 6 }



pmoabphcsAlmClientExtPumpEdfaLowCurrent OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Pump Low Current :This 
        OID indicates that the EDFA pump 
        current of Pre-Amp is too low because 
        of the external pump high power<Help> 
         This alarm (only active when there 
        is at least on external pump) indicates 
        that the EDFA pump current of the 
        Pre-Amp is too low because of the 
        external pump high power. <Condtype> 
        CLIENT_EXT_PUMP_EDFA_LOW_CURRENT 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5)  <Polarity>
         (2) 
        "
	  ::= { pmoabphcsAlmclientEdfaAlarms2 5 }



pmoabphcsAlmClientEdfaLos OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Loss Of Signal :This OID 
        indicates a Loss of Signal on the 
        Pre-Amp Optical Module  <Help>
          This alarm indicates if an optical 
        signal is detected on the Pre-Amp 
        input <Condtype> CLIENT_EDFA_LOS 
        <Probcause> receiveFailure (41) 
        <Alarmtype> physicalViolation (9) 
        <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmclientEdfaAlarms2 4 }



pmoabphcsAlmClientEdfaLaserFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Pump Laser Fail :This
         OID indicates a Transmit Laser 
        Fail on the Pre-Amp Optical Module 
         <Help>  This alarm indicates if 
        the laser of the Pre-Amp is in
         fail condition <Condtype> CLIENT_EDFA_LASER_FAIL 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmclientEdfaAlarms2 3 }



pmoabphcsAlmClientEdfaTecFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp TEC Fail :This OID indicates 
        that the TEC is in fail condition 
        on the Pre-Amp Optical Module 
         <Help>  This alarm indicates if 
        the TEC of the Pre-Amp is in fail 
        condition <Condtype> CLIENT_EDFA_TEC_FAIL 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmclientEdfaAlarms2 2 }



pmoabphcsAlmClientEdfaNr OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Optical Module Not Ready 
        :This OID indicates that the Pre-Amp 
        Optical Module is not ready  <Help> 
         This status indicates if the Pre-Amp 
        has been correctly initialized
         <Condtype> CLIENT_EDFA_NR <Probcause> 
        equipmentMalfunction (16) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmclientEdfaAlarms2 1 }



--- *****************************************************
---     LEAF for the clientMsaAlarms article
--- *****************************************************
pmoabphcsAlmclientMsaAlarms OBJECT IDENTIFIER ::= { pmoabphcsAlmClientCrit 37 }




pmoabphcsAlmClientMsaAttenuation OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp MSA Attenuation Alarm
         :This OID indicates the attenuation 
        on the Pre-Amp Mid Stage access 
        has changed.This alarm indicates 
        the attenuation on the Pre-Amp
         Mid Stage access has changed.
         <Condtype> CLIENT_MSA_ATTENUATION 
        <Probcause> performanceDegraded 
        <Alarmtype> equipmentAlarm (5)
          <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmclientMsaAlarms 2 }



pmoabphcsAlmClientMsaLos OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp MSA Loss Of Signal :This 
        OID indicates a Loss of Signal
         is detected on the Mid Stage Access 
        of the Pre-Amp EDFAThis alarm indicates 
        a Loss of Signal is detected on 
        the Mid Stage Access of the Pre-Amp 
        EDFA <Condtype> CLIENT_MSA_LOS
         <Probcause> inputOutputDeviceError(24) 
        <Alarmtype> equipmentAlarm (5)
          <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmclientMsaAlarms 1 }



--- *****************************************************
---     LEAF for the lineEdfaAlarms1 article
--- *****************************************************
pmoabphcsAlmlineEdfaAlarms1 OBJECT IDENTIFIER ::= { pmoabphcsAlmLineUrg 40 }




pmoabphcsAlmLineBiasHighAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Bias High Alarm :This
         OID indicates that the Bias is 
        higher than the alarm threshold 
        of the Booster Optical Module 
         <Help>  This alarm indicates if 
        the Booster bias is too high <Condtype> 
        LINE_BIAS_HIGH_ALARM <Probcause> 
        pumpFailure (39) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmlineEdfaAlarms1 8 }



pmoabphcsAlmLineBiasLowAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Bias Low Alarm :This OID 
        indicates that the Bias is lower 
        than the alarm threshold of the 
        Booster Optical Module  <Help>
          This alarm indicates if the Booster 
        bias is too low <Condtype> LINE_BIAS_LOW_ALARM 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmlineEdfaAlarms1 7 }



pmoabphcsAlmLineOutputPwrHighAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Tx Pwr High Alarm :This 
        OID indicates that the Transmit 
        Power is higher than the alarm
         threshold of the Booster Optical 
        Module  <Help>  This alarm indicates 
        if the Booster tx power is too
         high <Condtype> LINE_OUTPUT_PWR_HIGH_ALARM 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmlineEdfaAlarms1 6 }



pmoabphcsAlmLineOutputPwrLowAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Tx Pwr Low Alarm :This 
        OID indicates that the Transmit 
        Power is lower than the alarm threshold 
        of the Booster Optical Module 
         <Help>  This alarm indicates if 
        the Booster tx power is too low 
        <Condtype> LINE_OUTPUT_PWR_LOW_ALARM 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmlineEdfaAlarms1 5 }



pmoabphcsAlmLineInputPwrHighAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Rx Pwr High Alarm :This 
        OID indicates that the Receive
         Power is higher than the alarm 
        threshold of the Booster Optical 
        Module  <Help>  This alarm indicates 
        if the Booster rx power is too
         high <Condtype> LINE_INPUT_PWR_HIGH_ALARM 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmlineEdfaAlarms1 4 }



pmoabphcsAlmLineInputPwrLowAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Rx Pwr Low Alarm :This 
        OID indicates that the Receive
         Power is lower than the alarm
         threshold of the Booster Optical 
        Module  <Help>  This alarm indicates 
        if the Booster rx power is too
         low <Condtype> LINE_INPUT_PWR_LOW_ALARM 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmlineEdfaAlarms1 3 }



pmoabphcsAlmLineGainHighAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Gain High Alarm :This
         OID indicates that the Gain is 
        higher than the alarm threshold 
        of the Booster Module  <Help> 
         This alarm indicates if the Booster 
        gain is too high <Condtype> LINE_GAIN_HIGH_ALARM 
        <Probcause> performanceDegraded 
        (35) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmlineEdfaAlarms1 2 }



pmoabphcsAlmLineGainLowAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Gain Low Alarm :This OID 
        indicates that the Gain is lower 
        than the alarm threshold of the 
        Booster Module  <Help>  This alarm 
        indicates if the Booster gain is 
        too low <Condtype> LINE_GAIN_LOW_ALARM 
        <Probcause> performanceDegraded 
        (35) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmlineEdfaAlarms1 1 }



--- *****************************************************
---     LEAF for the lineEdfaWarnings article
--- *****************************************************
pmoabphcsAlmlineEdfaWarnings OBJECT IDENTIFIER ::= { pmoabphcsAlmLineNurg 41 }




pmoabphcsAlmLineBiasHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Bias High Warning :This 
        OID indicates that the Bias is
         higher than the Warning threshold 
        of the Booster Optical Module 
         <Help>  This warning indicates 
        if the Booster bias is too high 
        <Condtype> LINE_BIAS_HIGH_WARNING 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmlineEdfaWarnings 8 }



pmoabphcsAlmLineBiasLowWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Bias Low Warning :This 
        OID indicates that the Bias is
         lower than the Warning threshold 
        of the Booster Optical Module 
         <Help>  This warning indicates 
        if the Booster bias is too low
         <Condtype> LINE_BIAS_LOW_WARNING 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmlineEdfaWarnings 7 }



pmoabphcsAlmLineOutputPwrHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Tx Pwr High Warning :This 
        OID indicates that the Transmit 
        Power is higher than the Warning 
        threshold of the Booster Optical 
        Module  <Help>  This warning indicates 
        if the Booster tx power is too
         high <Condtype> LINE_OUTPUT_PWR_HIGH_WARNING 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmlineEdfaWarnings 6 }



pmoabphcsAlmLineOutputPwrLowWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Tx Pwr Low Warning :This 
        OID indicates that the Transmit 
        Power is lower than the Warning 
        threshold of the Booster Optical 
        Module  <Help>  This warning indicates 
        if the Booster tx power is too
         low <Condtype> LINE_OUTPUT_PWR_LOW_WARNING 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmlineEdfaWarnings 5 }



pmoabphcsAlmLineInputPwrHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Rx Pwr High Warning :This 
        OID indicates that the Receive
         Power is higher than the Warning 
        threshold of the Booster Optical 
        Module  <Help>  This warning indicates 
        if the Booster rx power is too
         high <Condtype> LINE_INPUT_PWR_HIGH_WARNING 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmlineEdfaWarnings 4 }



pmoabphcsAlmLineInputPwrLowWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Rx Pwr Low Warning :This 
        OID indicates that the Receive
         Power is lower than the Warning 
        threshold of the Booster Optical 
        Module  <Help>  This warning indicates 
        if the Booster rx power is too
         low <Condtype> LINE_INPUT_PWR_LOW_WARNING 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmlineEdfaWarnings 3 }



pmoabphcsAlmLineGainHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Gain High Warning :This 
        OID indicates that the Gain is
         higher than the Warning threshold 
        of the Booster Module  <Help> 
         This alarm indicates if the Booster 
        gain is too high <Condtype> LINE_GAIN_HIGH_WARNING 
        <Probcause> performanceDegraded 
        (35) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmlineEdfaWarnings 2 }



pmoabphcsAlmLineGainLowWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Gain Low Warning :This 
        OID indicates that the Gain is
         lower than the Warning threshold 
        of the Booster Module  <Help> 
         This alarm indicates if the Booster 
        gain is too low <Condtype> LINE_GAIN_LOW_WARNING 
        <Probcause> performanceDegraded 
        (35) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmlineEdfaWarnings 1 }



--- *****************************************************
---     LEAF for the lineEdfaAlarms2 article
--- *****************************************************
pmoabphcsAlmlineEdfaAlarms2 OBJECT IDENTIFIER ::= { pmoabphcsAlmLineCrit 43 }




pmoabphcsAlmLineGainOutOfRange OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Gain Out Of Range :This 
        OID indicates the target gain of 
        the Booster is out of range (10-18dB), 
        the flatness of the Booster is
         not guaranteed.<Help> This alarm 
        indicates the target gain of the 
        Booster is out of range (10-18dB), 
        the flatness of the Booster is
         not guaranteed. <Condtype> LINE_GAIN_OUT_OF_RANGE 
        <Probcause> other (1) <Alarmtype> 
        equipmentAlarm (5)  <Polarity>
         (2) 
        "
	  ::= { pmoabphcsAlmlineEdfaAlarms2 6 }



pmoabphcsAlmLineExtPumpEdfaLowCurrent OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Pump Low Current :This 
        OID indicates that the EDFA pump 
        current of Booster is too low because 
        of the external pump high power<Help> 
         This alarm (only active when there 
        is at least on external pump) indicates 
        that the EDFA pump current of the 
        Booster is too low because of the 
        external pump high power. <Condtype> 
        LINE_EXT_PUMP_EDFA_LOW_CURRENT
         <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5)  <Polarity>
         (2) 
        "
	  ::= { pmoabphcsAlmlineEdfaAlarms2 5 }



pmoabphcsAlmLineEdfaLos OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Loss Of Signal :This OID 
        indicates a Loss of Signal on the 
        Booster Optical Module  <Help>
          This alarm indicates if an optical 
        signal is detected on the Booster 
        input <Condtype> LINE_EDFA_LOS
         <Probcause> receiveFailure (41) 
        <Alarmtype> physicalViolation (9) 
        <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmlineEdfaAlarms2 4 }



pmoabphcsAlmLineEdfaLaserFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Pump Laser Fail :This
         OID indicates a Transmit Laser 
        Fail on the Booster Optical Module 
         <Help>  This alarm indicates if 
        the laser of the Booster is in
         fail condition <Condtype> LINE_EDFA_LASER_FAIL 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmlineEdfaAlarms2 3 }



pmoabphcsAlmLineEdfaTecFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster TEC Fail :This OID indicates 
        that the TEC is in fail condition 
        on the Booster Optical Module 
         <Help>  This alarm indicates if 
        the TEC of the Booster is in fail 
        condition <Condtype> LINE_EDFA_TEC_FAIL 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmlineEdfaAlarms2 2 }



pmoabphcsAlmLineEdfaNr OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Optical Module Not Ready 
        :This OID indicates that the Booster 
        Optical Module is not ready  <Help> 
         This status indicates if the Booster 
        has been correctly initialized
         <Condtype> LINE_EDFA_NR <Probcause> 
        equipmentMalfunction (16) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmlineEdfaAlarms2 1 }



--- *****************************************************
---     LEAF for the lineMsaAlarms article
--- *****************************************************
pmoabphcsAlmlineMsaAlarms OBJECT IDENTIFIER ::= { pmoabphcsAlmLineCrit 45 }




pmoabphcsAlmLineMsaAttenuation OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster MSA Attenuation Alarm
         :This OID indicates the attenuation 
        on the Booster Mid Stage access 
        has changed.This alarm indicates 
        the attenuation on the Pre-Amp
         Mid Stage access has changed.
         <Condtype> LINE_MSA_ATTENUATION 
        <Probcause> performanceDegraded 
        <Alarmtype> equipmentAlarm (5)
          <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmlineMsaAlarms 2 }



pmoabphcsAlmLineMsaLos OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster MSA Loss Of Signal :This 
        OID indicates a Loss of Signal
         is detected on the Mid Stage Access 
        of the Booster EDFAThis alarm indicates 
        a Loss of Signal is detected on 
        the Mid Stage Access of the Pre-Amp 
        EDFA <Condtype> LINE_MSA_LOS <Probcause> 
        inputOutputDeviceError(24) <Alarmtype> 
        equipmentAlarm (5)  <Polarity>
         (2) 
        "
	  ::= { pmoabphcsAlmlineMsaAlarms 1 }



--- *********************************************************
---     TABLE for the pmoabphcsAlmlineOscAlarms articles
--- *********************************************************

pmoabphcsAlmlineOscAlarmsTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PmoabphcsAlmlineOscAlarmsEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pmoabphcsAlmlineOscAlarms 
        Article
        "
	::= { pmoabphcsAlmLineCrit 48 }


pmoabphcsAlmlineOscAlarmsEntry OBJECT-TYPE
	SYNTAX PmoabphcsAlmlineOscAlarmsEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pmoabphcsAlmlineOscAlarms 
        table
        "
	INDEX   { pmoabphcsAlmlineOscAlarmsIndex }
	::= { pmoabphcsAlmlineOscAlarmsTable 1 }


PmoabphcsAlmlineOscAlarmsEntry ::=
	SEQUENCE {
	pmoabphcsAlmlineOscAlarmsIndex
		INTEGER,
	pmoabphcsAlmLineAlmPortn
		EkiOnOff,
	pmoabphcsAlmLineWarningPortn
		EkiOnOff,
	pmoabphcsAlmLineRemoteTxFailPortn
		EkiOnOff,
	pmoabphcsAlmLineOofPortn
		EkiOnOff,
	pmoabphcsAlmLineLofPortn
		EkiOnOff,
	pmoabphcsAlmLineOosPortn
		EkiOnOff,
	pmoabphcsAlmLineFecFailPortn
		EkiOnOff,
	pmoabphcsAlmLineTxFailPortn
		EkiOnOff,
	pmoabphcsAlmLineTxOffPortn
		EkiOnOff,
	pmoabphcsAlmLineLosPortn
		EkiOnOff
	}


pmoabphcsAlmlineOscAlarmsIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pmoabphcsAlmlineOscAlarms 
        table
        "
	::= { pmoabphcsAlmlineOscAlarmsEntry 1 }


pmoabphcsAlmLineAlmPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        OSC DDM Alarm :This alarm indicates 
        an alarm is present on OSC Tx power, 
        Rx power or temperature <Help>
         This alarm indicates an alarm
         is present on OSC Tx power, Rx 
        power or temperature <Condtype> 
        LINE_ALM_1 <Probcause> inputOutputDeviceError(24) 
        <Alarmtype> equipmentAlarm (5)
          <Polarity> (2) 
        "
	::= { pmoabphcsAlmlineOscAlarmsEntry 11 }


pmoabphcsAlmLineWarningPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        OSC DDM Warning :This OID indicates 
        a warning is present on OSC Tx
         power, Receive power or temperature<Help> 
        This alarm indicates a warning
         is present on OSC Tx power, Rx 
        power or temperature <Condtype> 
        LINE_WARNING_1 <Probcause> inputOutputDeviceError(24) 
        <Alarmtype> equipmentAlarm (5)
          <Polarity> (2) 
        "
	::= { pmoabphcsAlmlineOscAlarmsEntry 10 }


pmoabphcsAlmLineRemoteTxFailPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        OSC Remote Tx Fail : <Condtype> 
        LINE_REMOTE_TX_FAIL_1 <Probcause> 
        informationalStatus(1000) <Alarmtype> 
        other(1) <Polarity> (2) 
        "
	::= { pmoabphcsAlmlineOscAlarmsEntry 9 }


pmoabphcsAlmLineOofPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        OSC Out Of Frame : <Condtype>
         LINE_OOF_1 <Probcause> inputOutputDeviceError(24) 
        <Alarmtype> equipmentAlarm (5)
          <Polarity> (2) 
        "
	::= { pmoabphcsAlmlineOscAlarmsEntry 8 }


pmoabphcsAlmLineLofPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        OSC Loss Of Frame : <Condtype> 
        LINE_LOF_1 <Probcause> inputOutputDeviceError(24) 
        <Alarmtype> equipmentAlarm (5)
          <Polarity> (2) 
        "
	::= { pmoabphcsAlmlineOscAlarmsEntry 7 }


pmoabphcsAlmLineOosPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        OSC In Service :This OID indicates 
        that the OSC is In Service (1)
         or Out or Service (2)<Help> This 
        status indicates that the OSC is 
        In Service or Out or Service <Condtype> 
        LINE_OOS_1 <Probcause> informationalStatus(1000) 
        <Alarmtype> other(1) <Polarity> 
        (2) 
        "
	::= { pmoabphcsAlmlineOscAlarmsEntry 6 }


pmoabphcsAlmLineFecFailPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        OSC FEC Fail :This OID indicates 
        the FEC is in fail condition on 
        the OSC input port<Help> This alarms 
        indicates the FEC is in fail condition 
        on the OSC input port <Condtype> 
        LINE_FEC_FAIL_1 <Probcause> inputOutputDeviceError(24) 
        <Alarmtype> equipmentAlarm (5)
          <Polarity> (2) 
        "
	::= { pmoabphcsAlmlineOscAlarmsEntry 5 }


pmoabphcsAlmLineTxFailPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        OSC Tx Fail :This OID indicates 
        the OSC Laser is in fail condition<Help> 
        This alarm indicates the OSC Laser 
        is in fail condition <Condtype> 
        LINE_TX_FAIL_1 <Probcause> transmitterFailure 
        (56) <Alarmtype> equipmentAlarm 
        (5)  <Polarity> (2) 
        "
	::= { pmoabphcsAlmlineOscAlarmsEntry 4 }


pmoabphcsAlmLineTxOffPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        OSC Optical Output Shutdown :This 
        OID indicates the optical output 
        power is shutdown on OSC<Help>
         This alarm indicates the optical 
        output power is shutdown on OSC 
        <Condtype> LINE_TX_OFF_1 <Probcause> 
        other(1) <Alarmtype> equipmentAlarm 
        (5)  <Polarity> (2) 
        "
	::= { pmoabphcsAlmlineOscAlarmsEntry 3 }


pmoabphcsAlmLineLosPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        OSC Loss Of Signal :This OID indicates 
        that no signal is present on the 
        OSC <Help> This alarms indicates 
        that no signal is present on the 
        OSC <Condtype> LINE_LOS_1 <Probcause> 
        inputOutputDeviceError(24) <Alarmtype> 
        equipmentAlarm (5)  <Polarity>
         (2) 
        "
	::= { pmoabphcsAlmlineOscAlarmsEntry 2 }


--- *********************************************************
---     TABLE for the pmoabphcsAlmlineOscThresholdAlarms articles
--- *********************************************************

pmoabphcsAlmlineOscThresholdAlarmsTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PmoabphcsAlmlineOscThresholdAlarmsEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pmoabphcsAlmlineOscThresholdAlarms 
        Article
        "
	::= { pmoabphcsAlmLineCrit 49 }


pmoabphcsAlmlineOscThresholdAlarmsEntry OBJECT-TYPE
	SYNTAX PmoabphcsAlmlineOscThresholdAlarmsEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pmoabphcsAlmlineOscThresholdAlarms 
        table
        "
	INDEX   { pmoabphcsAlmlineOscThresholdAlarmsIndex }
	::= { pmoabphcsAlmlineOscThresholdAlarmsTable 1 }


PmoabphcsAlmlineOscThresholdAlarmsEntry ::=
	SEQUENCE {
	pmoabphcsAlmlineOscThresholdAlarmsIndex
		INTEGER,
	pmoabphcsAlmLineOscBiasHighAlarmPortn
		EkiOnOff,
	pmoabphcsAlmLineOscBiasLowAlarmPortn
		EkiOnOff,
	pmoabphcsAlmLineSpanlossHighAlarmPortn
		EkiOnOff,
	pmoabphcsAlmLineSpanlossLowAlarmPortn
		EkiOnOff,
	pmoabphcsAlmLineRxPwrHighAlarmPortn
		EkiOnOff,
	pmoabphcsAlmLineRxPwrLowAlarmPortn
		EkiOnOff,
	pmoabphcsAlmLineTxPwrHighAlarmPortn
		EkiOnOff,
	pmoabphcsAlmLineTxPwrLowAlarmPortn
		EkiOnOff
	}


pmoabphcsAlmlineOscThresholdAlarmsIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pmoabphcsAlmlineOscThresholdAlarms 
        table
        "
	::= { pmoabphcsAlmlineOscThresholdAlarmsEntry 1 }


pmoabphcsAlmLineOscBiasHighAlarmPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        OSC Bias Current High Alarm :This 
        OID indicates the OSC bias current 
        is higher than the alarm threshold 
         <Help> This alarm indicates the 
        OSC bias current is higher than 
        the alarm threshold <Condtype>
         LINE_OSC_BIAS_HIGH_ALARM_1 <Probcause> 
        inputOutputDeviceError(24) <Alarmtype> 
        equipmentAlarm (5)  <Polarity>
         (2) 
        "
	::= { pmoabphcsAlmlineOscThresholdAlarmsEntry 9 }


pmoabphcsAlmLineOscBiasLowAlarmPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        OSC Bias Current Low Alarm :This 
        OID indicates the OSC bias current 
        is lower than the alarm threshold 
         <Help> This alarm indicates the 
        OSC bias current is lower than
         the alarm threshold <Condtype> 
        LINE_OSC_BIAS_LOW_ALARM_1 <Probcause> 
        inputOutputDeviceError(24) <Alarmtype> 
        equipmentAlarm (5)  <Polarity>
         (2) 
        "
	::= { pmoabphcsAlmlineOscThresholdAlarmsEntry 8 }


pmoabphcsAlmLineSpanlossHighAlarmPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        OSC Span Loss High Alarm :This 
        OID indicates the OSC Span Loss 
        is 3dB higher than the span loss 
        reference <Help> This alarm indicates 
        the OSC Span Loss is 3dB higher 
        than the span loss reference <Condtype> 
        LINE_SPANLOSS_HIGH_ALARM_1 <Probcause> 
        inputOutputDeviceError(24) <Alarmtype> 
        equipmentAlarm (5)  <Polarity>
         (2) 
        "
	::= { pmoabphcsAlmlineOscThresholdAlarmsEntry 7 }


pmoabphcsAlmLineSpanlossLowAlarmPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        OSC Span Loss Low Alarm :This
         OID indicates the OSC Span Loss 
        is 3dB lower than the span loss 
        reference<Help> This alarm indicates 
        the OSC Span Loss is 3dB lower
         than the span loss reference <Condtype> 
        LINE_SPANLOSS_LOW_ALARM_1 <Probcause> 
        inputOutputDeviceError(24) <Alarmtype> 
        equipmentAlarm (5)  <Polarity>
         (2) 
        "
	::= { pmoabphcsAlmlineOscThresholdAlarmsEntry 6 }


pmoabphcsAlmLineRxPwrHighAlarmPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        OSC Rx Power High Alarm :This
         OID indicates the Rx Power of
         the OSC is higher than the alarm 
        threshold<Help> This alarm indicates 
        the Rx Power of the OSC is higher 
        than the alarm threshold <Condtype> 
        LINE_RX_PWR_HIGH_ALARM_1 <Probcause> 
        inputOutputDeviceError(24) <Alarmtype> 
        equipmentAlarm (5)  <Polarity>
         (2) 
        "
	::= { pmoabphcsAlmlineOscThresholdAlarmsEntry 5 }


pmoabphcsAlmLineRxPwrLowAlarmPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        OSC Rx Power Low Alarm :This OID 
        indicates the Rx Power of the OSC 
        is lower than the alarm threshold<Help> 
        This alarm indicates the Rx Power 
        of the OSC is lower than the alarm 
        threshold <Condtype> LINE_RX_PWR_LOW_ALARM_1 
        <Probcause> inputOutputDeviceError(24) 
        <Alarmtype> equipmentAlarm (5)
          <Polarity> (2) 
        "
	::= { pmoabphcsAlmlineOscThresholdAlarmsEntry 4 }


pmoabphcsAlmLineTxPwrHighAlarmPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        OSC Tx Power High Alarm :This
         OID indicates the Tx Power of
         the OSC is higher than the warning 
        threshold<Help> This alarm indicates 
        the Tx Power of the OSC is higher 
        than the alarm threshold <Condtype> 
        LINE_TX_PWR_HIGH_ALARM_1 <Probcause> 
        inputOutputDeviceError(24) <Alarmtype> 
        equipmentAlarm (5)  <Polarity>
         (2) 
        "
	::= { pmoabphcsAlmlineOscThresholdAlarmsEntry 3 }


pmoabphcsAlmLineTxPwrLowAlarmPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        OSC Tx Power Low Alarm :This OID 
        indicates the Tx Power of the OSC 
        is lower than the warning threshold<Help> 
        This alarm indicates the Tx Power 
        of the OSC is lower than the alarm 
        threshold <Condtype> LINE_TX_PWR_LOW_ALARM_1 
        <Probcause> inputOutputDeviceError(24) 
        <Alarmtype> equipmentAlarm (5)
          <Polarity> (2) 
        "
	::= { pmoabphcsAlmlineOscThresholdAlarmsEntry 2 }


--- *********************************************************
---     TABLE for the pmoabphcsAlmlineOscThresholdsWarnings articles
--- *********************************************************

pmoabphcsAlmlineOscThresholdsWarningsTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PmoabphcsAlmlineOscThresholdsWarningsEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pmoabphcsAlmlineOscThresholdsWarnings 
        Article
        "
	::= { pmoabphcsAlmLineCrit 50 }


pmoabphcsAlmlineOscThresholdsWarningsEntry OBJECT-TYPE
	SYNTAX PmoabphcsAlmlineOscThresholdsWarningsEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pmoabphcsAlmlineOscThresholdsWarnings 
        table
        "
	INDEX   { pmoabphcsAlmlineOscThresholdsWarningsIndex }
	::= { pmoabphcsAlmlineOscThresholdsWarningsTable 1 }


PmoabphcsAlmlineOscThresholdsWarningsEntry ::=
	SEQUENCE {
	pmoabphcsAlmlineOscThresholdsWarningsIndex
		INTEGER,
	pmoabphcsAlmLineOscBiasHighWarningPortn
		EkiOnOff,
	pmoabphcsAlmLineOscBiasLowWarningPortn
		EkiOnOff,
	pmoabphcsAlmLineSpanlossHighWarningPortn
		EkiOnOff,
	pmoabphcsAlmLineSpanlossLowWarningPortn
		EkiOnOff,
	pmoabphcsAlmLineRxPwrHighWarningPortn
		EkiOnOff,
	pmoabphcsAlmLineRxPwrLowWarningPortn
		EkiOnOff,
	pmoabphcsAlmLineTxPwrHighWarningPortn
		EkiOnOff,
	pmoabphcsAlmLineTxPwrLowWarningPortn
		EkiOnOff
	}


pmoabphcsAlmlineOscThresholdsWarningsIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pmoabphcsAlmlineOscThresholdsWarnings 
        table
        "
	::= { pmoabphcsAlmlineOscThresholdsWarningsEntry 1 }


pmoabphcsAlmLineOscBiasHighWarningPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        OSC Bias Current High Warning
         :This OID indicates the OSC bias 
        current is higher than the warning 
        threshold  <Help> This alarm indicates 
        the OSC bias current is higher
         than the warning threshold <Condtype> 
        LINE_OSC_BIAS_HIGH_WARNING_1 <Probcause> 
        inputOutputDeviceError(24) <Alarmtype> 
        equipmentAlarm (5)  <Polarity>
         (2) 
        "
	::= { pmoabphcsAlmlineOscThresholdsWarningsEntry 9 }


pmoabphcsAlmLineOscBiasLowWarningPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        OSC Bias Current Low Warning :This 
        OID indicates the OSC bias current 
        is lower than the warning threshold 
         <Help> This alarm indicates the 
        OSC bias current is lower than
         the warning threshold <Condtype> 
        LINE_OSC_BIAS_LOW_WARNING_1 <Probcause> 
        inputOutputDeviceError(24) <Alarmtype> 
        equipmentAlarm (5)  <Polarity>
         (2) 
        "
	::= { pmoabphcsAlmlineOscThresholdsWarningsEntry 8 }


pmoabphcsAlmLineSpanlossHighWarningPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        OSC Span Loss High Warning :This 
        OID indicates the OSC Span Loss 
        is 1dB higher than the span loss 
        reference <Help> This alarm indicates 
        the OSC Span Loss is 1dB higher 
        than the span loss reference <Condtype> 
        LINE_SPANLOSS_HIGH_WARNING_1 <Probcause> 
        inputOutputDeviceError(24) <Alarmtype> 
        equipmentAlarm (5)  <Polarity>
         (2) 
        "
	::= { pmoabphcsAlmlineOscThresholdsWarningsEntry 7 }


pmoabphcsAlmLineSpanlossLowWarningPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        OSC Span Loss Low Warning :This 
        OID indicates the OSC Span Loss 
        is 1dB lower than the span loss 
        reference<Help> This alarm indicates 
        the OSC Span Loss is 1dB lower
         than the span loss reference <Condtype> 
        LINE_SPANLOSS_LOW_WARNING_1 <Probcause> 
        inputOutputDeviceError(24) <Alarmtype> 
        equipmentAlarm (5)  <Polarity>
         (2) 
        "
	::= { pmoabphcsAlmlineOscThresholdsWarningsEntry 6 }


pmoabphcsAlmLineRxPwrHighWarningPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        OSC Rx Power High Warning :This 
        OID indicates the Rx Power of the 
        OSC is higher than the warning
         threshold<Help> This alarm indicates 
        the Rx Power of the OSC is higher 
        than the warning threshold <Condtype> 
        LINE_RX_PWR_HIGH_WARNING_1 <Probcause> 
        inputOutputDeviceError(24) <Alarmtype> 
        equipmentAlarm (5)  <Polarity>
         (2) 
        "
	::= { pmoabphcsAlmlineOscThresholdsWarningsEntry 5 }


pmoabphcsAlmLineRxPwrLowWarningPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        OSC Rx Power Low Warning :This 
        OID indicates the Rx Power of the 
        OSC is lower than the warning threshold<Help> 
        This alarm indicates the Tx Power 
        of the OSC is lower than the warning 
        threshold <Condtype> LINE_RX_PWR_LOW_WARNING_1 
        <Probcause> inputOutputDeviceError(24) 
        <Alarmtype> equipmentAlarm (5)
          <Polarity> (2) 
        "
	::= { pmoabphcsAlmlineOscThresholdsWarningsEntry 4 }


pmoabphcsAlmLineTxPwrHighWarningPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        OSC Tx Power High Warning :This 
        OID indicates the Tx Power of the 
        OSC is higher than the warning
         threshold<Help> This alarm indicates 
        the Tx Power of the OSB is higher 
        than the warning threshold <Condtype> 
        LINE_TX_PWR_HIGH_WARNING_1 <Probcause> 
        inputOutputDeviceError(24) <Alarmtype> 
        equipmentAlarm (5)  <Polarity>
         (2) 
        "
	::= { pmoabphcsAlmlineOscThresholdsWarningsEntry 3 }


pmoabphcsAlmLineTxPwrLowWarningPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        OSC Tx Power Low Warning :This 
        OID indicates the Tx Power of the 
        OSC is lower than the warning threshold<Help> 
        This alarm indicates the Tx Power 
        of the OSC is lower than the warning 
        threshold <Condtype> LINE_TX_PWR_LOW_WARNING_1 
        <Probcause> inputOutputDeviceError(24) 
        <Alarmtype> equipmentAlarm (5)
          <Polarity> (2) 
        "
	::= { pmoabphcsAlmlineOscThresholdsWarningsEntry 2 }


--- *****************************************************
---     LEAF for the foaAlarms article
--- *****************************************************
pmoabphcsAlmfoaAlarms OBJECT IDENTIFIER ::= { pmoabphcsAlmOtherUrg 74 }




pmoabphcsAlmTempHighAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Temperature High Alarm :This OID 
        indicates that the PM temperature 
        is higher than the alarm threshold 
        <Condtype> TEMP_HIGH_ALARM <Probcause> 
        temperatureUnacceptable (51) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmfoaAlarms 8 }



pmoabphcsAlmTermpLowAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Temperature Low Alarm :This OID 
        indicates that the PM temperature 
        if lower than the alarm threshold 
        <Condtype> TERMP_LOW_ALARM <Probcause> 
        temperatureUnacceptable (51) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmfoaAlarms 7 }



--- *****************************************************
---     LEAF for the foaWarnings article
--- *****************************************************
pmoabphcsAlmfoaWarnings OBJECT IDENTIFIER ::= { pmoabphcsAlmOtherNurg 75 }




pmoabphcsAlmTempHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Temperature High Warning :This 
        OID indicates that the PM temperature 
        if higher than the Warning threshold 
        <Condtype> TEMP_HIGH_WARNING <Probcause> 
        temperatureUnacceptable (51) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmfoaWarnings 8 }



pmoabphcsAlmTermpLowWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Temperature Low Warning :This
         OID indicates that the PM temperature 
        if lower than the Warning threshold 
        <Condtype> TERMP_LOW_WARNING <Probcause> 
        temperatureUnacceptable (51) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcsAlmfoaWarnings 7 }








--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     CONTROLS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the synth0 article
--- *****************************************************
pmoabphcsCtrlsynth0 OBJECT IDENTIFIER ::= { pmoabphcsCtrlOther 0 }




pmoabphcsCtrlConfClear OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Clear Configuration Tables :This 
        bit clears the configuration tables 
        from configuration in the flash. 
         <Help>  This control restores
         the default configuration of the 
        module
        "
	  ::= { pmoabphcsCtrlsynth0 13 }



pmoabphcsCtrlConfFlash OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Write Configuration Tables :This 
        bit saves the current configuration 
        of the module as configuration
         in the flash.  <Help>  This control 
        saves the customer configuration 
        on the module
        "
	  ::= { pmoabphcsCtrlsynth0 9 }



pmoabphcsCtrlConfLoad OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Load Configuration Tables :When 
        set this enables loading from flash 
        configuration1 into the module.
        "
	  ::= { pmoabphcsCtrlsynth0 1 }



--- *****************************************************
---     LEAF for the swMgnt article
--- *****************************************************
pmoabphcsCtrlswMgnt OBJECT IDENTIFIER ::= { pmoabphcsCtrlOther 5 }




pmoabphcsCtrlWarmReset OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        PM Warm Reset :This OID, when
         set, causes a warm reset of the 
        Software. This reset is not traffic 
        affecting, and the configuration 
        of the Sofwtare remains unchanged. 
         <Help>  This control initiates 
        a warm reset of the module.
        "
	  ::= { pmoabphcsCtrlswMgnt 3 }



pmoabphcsCtrlColdReset OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        PM Cold Reset :This OID, when
         set, causes a cold reset of the 
        Software. This reset is traffic 
        affecting, and the configuration 
        of Software is reloaded on start-up. 
         <Help>  This control initiates 
        a cold reset of the module.
        "
	  ::= { pmoabphcsCtrlswMgnt 2 }



--- *****************************************************
---     LEAF for the clientOscInputSpanLoss article
--- *****************************************************
pmoabphcsCtrlclientOscInputSpanLoss OBJECT IDENTIFIER ::= { pmoabphcsCtrlClient 33 }




pmoabphcsCtrlClientSpanLoss OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Store Pre-Amp Input Span Loss
         :This OID stores the current input 
        span Loss as a reference to monitor 
        the span loss variation <Help>
         This parameter stores the current 
         input span Loss as a reference 
        to monitor the span loss variation
        "
	  ::= { pmoabphcsCtrlclientOscInputSpanLoss 1 }



--- *****************************************************
---     LEAF for the clientGainCstMonitorValue article
--- *****************************************************

pmoabphcsCtrlclientGainCstMonitorValue OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Fiber Aging Period :This 
        OID sets the value of the monitoring 
        period to detect a fiber aging. 
        (Unit = s) This value sets the
         monitoring period to detect a
         fiber aging.
        "
	  ::= { pmoabphcsCtrlClient 34 }



--- *****************************************************
---     LEAF for the clientGainSettingValue article
--- *****************************************************

pmoabphcsCtrlclientGainSettingValue OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Gain Target :This OID
         sets the value of the nominal
         gain of the Pre-Amplifier Module 
        (active only in constant output 
        power mode) (AV=(Gain/0,005) +
         32768) (Unit = dB)<Help> This
         control sets the value of the
         nominal gain of the Pre- Amplifier 
        Module (active only in constant 
        output power mode)
        "
	  ::= { pmoabphcsCtrlClient 36 }



--- *****************************************************
---     LEAF for the clientGainProcessing article
--- *****************************************************
pmoabphcsCtrlclientGainProcessing OBJECT IDENTIFIER ::= { pmoabphcsCtrlClient 37 }




pmoabphcsCtrlClientGainProc OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Gain Adjustment :This
         OID initiates the automatic nominal 
        gain adjustment on the Pre-Amplifier 
        Module<Help> This control initiates 
        the automatic nominal gain adjustment 
        on the Pre-Amplifier Module
        "
	  ::= { pmoabphcsCtrlclientGainProcessing 1 }



--- *****************************************************
---     LEAF for the clientGainCstFiberAgingMarginValue article
--- *****************************************************

pmoabphcsCtrlclientGainCstFiberAgingMarginValue OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Aging Threshold :This
         OID sets the threshold to consider 
        the power drop as a fiber aging. 
        (active only in constant gain mode) 
        (AV=(Gain/0,005) + 32768) (Unit 
        = dB) <Help> This value defines 
        the threshold to consider the power 
        drop as a fiber aging.
        "
	  ::= { pmoabphcsCtrlClient 38 }



--- *****************************************************
---     LEAF for the clientMsaAttenuationValue article
--- *****************************************************
pmoabphcsCtrlclientMsaAttenuationValue OBJECT IDENTIFIER ::= { pmoabphcsCtrlClient 40 }




pmoabphcsCtrlClientAttenuation OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Store Pre-Amp MSA Attenuation
         :This OID stores the current attenuation 
        applied on the Mid Stage Access 
        of the Pre-Amp (used for monitoring 
        the MSA attenuation variation)<Help> 
        This parameter stores the current 
        attenuation applied on the Mid
         Stage Access of the Pre-Amp (used 
        for monitoring the MSA attenuation 
        variation)
        "
	  ::= { pmoabphcsCtrlclientMsaAttenuationValue 1 }



--- *****************************************************
---     LEAF for the lineOscInputSpanLoss article
--- *****************************************************
pmoabphcsCtrllineOscInputSpanLoss OBJECT IDENTIFIER ::= { pmoabphcsCtrlLine 49 }




pmoabphcsCtrlLineSpanLoss OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Store Booster Input Span Loss
         :This OID stores the current input 
        span Loss as a reference to monitor 
        the span loss variation<Help> This 
        parameter stores the current  input 
        span Loss as a reference to monitor 
        the span loss variation
        "
	  ::= { pmoabphcsCtrllineOscInputSpanLoss 1 }



--- *****************************************************
---     LEAF for the lineGainCstMonitorValue article
--- *****************************************************

pmoabphcsCtrllineGainCstMonitorValue OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Booster Fiber Aging Period :This 
        OID sets the value of the monitoring 
        period to detect a fiber aging. 
        (Unit = s) This value sets the
         monitoring period to detect a
         fiber aging.
        "
	  ::= { pmoabphcsCtrlLine 50 }



--- *****************************************************
---     LEAF for the lineGainSettingValue article
--- *****************************************************

pmoabphcsCtrllineGainSettingValue OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Booster Gain Target :This OID
         sets the value of the nominal
         gain of the Booster Module (active 
        only in constant output power mode) 
        (AV=(Gain/0,005) + 32768) (Unit 
        = dB) <Help> This control sets
         the value of the nominal gain
         of the Booster Module (active
         only in constant output power
         mode)
        "
	  ::= { pmoabphcsCtrlLine 52 }



--- *****************************************************
---     LEAF for the lineGainProcessing article
--- *****************************************************
pmoabphcsCtrllineGainProcessing OBJECT IDENTIFIER ::= { pmoabphcsCtrlLine 53 }




pmoabphcsCtrlLineGainProc OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Booster Gain Adjustment :This
         OID initiates the automatic nominal 
        gain adjustment on the Booster
         Module<Help> This control initiates 
        the automatic nominal gain adjustment 
        on the Booster Module
        "
	  ::= { pmoabphcsCtrllineGainProcessing 1 }



--- *****************************************************
---     LEAF for the lineGainCstFiberAgingMarginValue article
--- *****************************************************

pmoabphcsCtrllineGainCstFiberAgingMarginValue OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Booster Aging Threshold :This
         OID sets the threshold to consider 
        the power drop as a fiber aging. 
        (active only in constant gain mode) 
        (AV=(Gain/0,005) + 32768) (Unit 
        = dB) <Help> This value defines 
        the threshold to consider the power 
        drop as a fiber aging.
        "
	  ::= { pmoabphcsCtrlLine 54 }



--- *****************************************************
---     LEAF for the lineMsaAttenuationValue article
--- *****************************************************
pmoabphcsCtrllineMsaAttenuationValue OBJECT IDENTIFIER ::= { pmoabphcsCtrlLine 56 }




pmoabphcsCtrlLineAttenuation OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Store Booster MSA Attenuation
         :This OID stores the current attenuation 
        applied on the Mid Stage Access 
        of the Booster (used for monitoring 
        the MSA attenuation variation)<Help> 
        This parameter stores the current 
        attenuation applied on the Mid
         Stage Access of the Booster (used 
        for monitoring the MSA attenuation 
        variation)
        "
	  ::= { pmoabphcsCtrllineMsaAttenuationValue 1 }



--- *****************************************************
---     LEAF for the ledTest article
--- *****************************************************
pmoabphcsCtrlledTest OBJECT IDENTIFIER ::= { pmoabphcsCtrlOther 73 }




pmoabphcsCtrlLedOff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Leds Off :This OID switches off 
        all the Leds as a test feature. 
         <Help>  This control initiates 
        a test leds turning all the LEDs 
        to OFF
        "
	  ::= { pmoabphcsCtrlledTest 3 }



pmoabphcsCtrlRedLed OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Red Leds Test :This OID switches 
        on all the red Leds as a test feature. 
         <Help>  This control initiates 
        a test leds turning all the LEDs 
        to red
        "
	  ::= { pmoabphcsCtrlledTest 2 }



pmoabphcsCtrlGreenLed OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Green Leds Test :This OID switches 
        on all the green Leds as a test 
        feature.  <Help>  This control
         initiates a test leds turning
         all the LEDs to green
        "
	  ::= { pmoabphcsCtrlledTest 1 }



--- *****************************************************
---     LEAF for the maintMode article
--- *****************************************************
pmoabphcsCtrlmaintMode OBJECT IDENTIFIER ::= { pmoabphcsCtrlOther 75 }




pmoabphcsCtrlMaintenance OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        PM Maintenance Mode :This OID
         sets the PM in maintenance mode 
         <Help>  This control enables the 
        maintenance mode of the module
        "
	  ::= { pmoabphcsCtrlmaintMode 1 }



--- *****************************************************
---     LEAF for the aprRestart article
--- *****************************************************
pmoabphcsCtrlaprRestart OBJECT IDENTIFIER ::= { pmoabphcsCtrlOther 76 }




pmoabphcsCtrlAprManualRestart OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        APR Manual Restart :This OID initiates 
        the Restart mechanism to retrieve 
        from the APR state.<Help> This
         control initiates the Restart
         mechanism to retrieve from the 
        APR state.
        "
	  ::= { pmoabphcsCtrlaprRestart 1 }








--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     COUNTERS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *********************************************************
---     TABLE for the pmoabphcsCntlineOscErr articles
--- *********************************************************

pmoabphcsCntlineOscErrTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PmoabphcsCntlineOscErrEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pmoabphcsCntlineOscErr 
        Article
        "
	::= { pmoabphcsCntLine 16 }


pmoabphcsCntlineOscErrEntry OBJECT-TYPE
	SYNTAX PmoabphcsCntlineOscErrEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pmoabphcsCntlineOscErr 
        table
        "
	INDEX   { pmoabphcsCntlineOscErrIndex }
	::= { pmoabphcsCntlineOscErrTable 1 }


PmoabphcsCntlineOscErrEntry ::=
	SEQUENCE {
	pmoabphcsCntlineOscErrIndex
		INTEGER,
	pmoabphcsCntlineOscErrValuePortn
		Counter32,
	pmoabphcsCntlineOscErrErrorPortn
		EkiOnOff,
	pmoabphcsCntlineOscErrOverloadPortn
		EkiOnOff
	}


pmoabphcsCntlineOscErrIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pmoabphcsCntlineOscErr 
        table
        "
	::= { pmoabphcsCntlineOscErrEntry 1 }


pmoabphcsCntlineOscErrValuePortn OBJECT-TYPE
	SYNTAX  Counter32
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        OSC FEC Counter :This OID indicates 
        the number of errors corrected
         by the FEC of the OSC<Help> This 
        measure indicates the number of 
        errors corrected by the FEC of
         the OSC
        "
	::= { pmoabphcsCntlineOscErrEntry 2 }


pmoabphcsCntlineOscErrErrorPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        B1 Counter Error :This OID when 
        set indicates the B1 counter value 
        is invalid on Port
        "
	::= { pmoabphcsCntlineOscErrEntry 3 }


pmoabphcsCntlineOscErrOverloadPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        B1 Counter Overload :This OID
         when set indicates a B1 error
         counter overload on Port
        "
	::= { pmoabphcsCntlineOscErrEntry 4 }


pmoabphcsCntCountersReset  OBJECT-TYPE
	SYNTAX EkiOnOff
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
	"Counters Reset:This OID resets and restarts all the counters"
	::= { pmoabphcscounters  259 }

pmoabphcsCntCountersStop  OBJECT-TYPE
	SYNTAX EkiOnOff
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
	"Counters stop:This OID stops all the counters"
	::= { pmoabphcscounters 260 }






--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     MEASURES
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the clientEdfaBiasMeas article
--- *****************************************************

pmoabphcsMesrclientEdfaBiasMeas OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Pump Laser Current :This 
        OID gives the pump laser current 
        of the Pre-Amp Optical Module (Current 
        =AV/100) (Unit = mA)  <Help>  This 
        measure gives the bias of the Pre-Amp 
        pump laser
        "
	  ::= { pmoabphcsMesrClient 32 }



--- *****************************************************
---     LEAF for the clientEdfaTxpwrMeas article
--- *****************************************************

pmoabphcsMesrclientEdfaTxpwrMeas OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Tx Power :This OID gives 
        the transmit power value of the 
        Pre-Amp Optical Module (Power =(AV-32768)*0,005) 
         (Unit = dBm)  <Help>  This measure 
        gives the Tx optical power of the 
        Pre-Amp
        "
	  ::= { pmoabphcsMesrClient 33 }



--- *****************************************************
---     LEAF for the clientEdfaRxpwrMeas article
--- *****************************************************

pmoabphcsMesrclientEdfaRxpwrMeas OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Rx Power :This OID gives 
        the receive power value of the
         Pre-Amp Optical Module (Power
         =(AV-32768)*0,005) (Unit = dBm) 
         <Help>  This measure gives the 
        Rx optical power of the Pre-Amp
        "
	  ::= { pmoabphcsMesrClient 34 }



--- *****************************************************
---     LEAF for the clientEdfaGainMeas article
--- *****************************************************

pmoabphcsMesrclientEdfaGainMeas OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Gain Target :This OID
         gives the gain value of the Pre-Amp 
        Module  (Gain =(AV-32768)*0,005) 
        (Unit = dB)  <Help> This information 
        gives the target gain of the amplifier 
        for optimal performance
        "
	  ::= { pmoabphcsMesrClient 35 }



--- *****************************************************
---     LEAF for the clientOscSpanLoss article
--- *****************************************************

pmoabphcsMesrclientOscSpanLoss OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Input Span Loss :This
         OID indicates the attenuation
         of the span connected to the Pre-amp 
        input (Power =(AV-32768)*0,005) 
         (Unit = dB) <Help> This measure 
        indicates the attenuation of the 
        span connected to the Pre-amp input
        "
	  ::= { pmoabphcsMesrClient 36 }



--- *****************************************************
---     LEAF for the clientOscSpanLossRef article
--- *****************************************************

pmoabphcsMesrclientOscSpanLossRef OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Input Span Loss Ref :This 
        OID indicates the referenced attenuation 
        of the span connected to the Pre-amp 
        input (Used to monitor the variation 
        of the span loss)  (Power =(AV-32768)*0,005) 
         (Unit = dB) <Help> This measure 
        indicates the referenced attenuation 
        of the span connected to the Pre-amp 
        input (Used to monitor the variation 
        of the span loss)
        "
	  ::= { pmoabphcsMesrClient 37 }



--- *****************************************************
---     LEAF for the clientCorrectedGain article
--- *****************************************************

pmoabphcsMesrclientCorrectedGain OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Gain :This OID gives the 
        gain value of the Pre-Amp Module 
        corrected by the ASE compensation 
        mechanism (Gain =(AV-32768)*0,005) 
        (Unit = dB)   <Help>  This measure 
        gives the effective gain of the 
        amplifier
        "
	  ::= { pmoabphcsMesrClient 38 }



--- *****************************************************
---     LEAF for the clientMsaInputPower article
--- *****************************************************

pmoabphcsMesrclientMsaInputPower OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp MSA Rx Power :This OID 
        indicates the input power of the 
        Mid Stage Access of the Pre-Amp 
        (Power =(AV-32768)*0,005) (Unit 
        = dBm)   <Help> This measure indicates 
        the input power of the Mid Stage 
        Access of the Pre-Amp
        "
	  ::= { pmoabphcsMesrClient 39 }



--- *****************************************************
---     LEAF for the clientMsaOutputPower article
--- *****************************************************

pmoabphcsMesrclientMsaOutputPower OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp MSA Tx Power :This OID 
        indicates the output power of the 
        Mid Stage Access of the Pre-Amp 
        (Power =(AV-32768)*0,005) (Unit 
        = dBm)   <Help> This measure indicates 
        the output power of the Mid Stage 
        Access of the Pre-Amp
        "
	  ::= { pmoabphcsMesrClient 40 }



--- *****************************************************
---     LEAF for the clientMsaAttenuation article
--- *****************************************************

pmoabphcsMesrclientMsaAttenuation OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp MSA Attenuation :This
         OID indicates the attenuation
         applied on the Mid Stage Access 
        of the Pre-Amp (Attenuation =(AV-32768)*0,005) 
        (Unit = dB)   <Help> This measure 
        indicates the attenuation applied 
        on the Mid Stage Access of the
         Pre-Amp
        "
	  ::= { pmoabphcsMesrClient 41 }



--- *****************************************************
---     LEAF for the clientMsaAttenuationRef article
--- *****************************************************

pmoabphcsMesrclientMsaAttenuationRef OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp MSA Attenuation Ref :This 
        OID indicates the reference attenuation 
        stored for the Mid Stage Access 
        of the In-Line1 (Used to monitor 
        the variation of this attenuation) 
        (Attenuation =(AV-32768)*0,005) 
        (Unit = dB)   <Help> This measure 
        indicates the reference attenuation 
        stored for the Mid Stage Access 
        of the Pre-Amp (Used to monitor 
        the variation of this attenuation)
        "
	  ::= { pmoabphcsMesrClient 42 }



--- *****************************************************
---     LEAF for the lineEdfaBiasMeas article
--- *****************************************************

pmoabphcsMesrlineEdfaBiasMeas OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Pump Laser Current :This 
        OID gives the pump laser current 
        of the Booster Optical Module 
         (Current =AV/100) (Unit = mA)
          <Help>  This measure gives the 
        bias of the Booster pump laser
        "
	  ::= { pmoabphcsMesrLine 48 }



--- *****************************************************
---     LEAF for the lineEdfaTxpwrMeas article
--- *****************************************************

pmoabphcsMesrlineEdfaTxpwrMeas OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Tx Power :This OID gives 
        the transmit power value of the 
        Booster Optical Module (Power =(AV-32768)*0,005) 
        (Unit = dBm)  <Help>  This measure 
        gives the Tx optical power of the 
        Booster
        "
	  ::= { pmoabphcsMesrLine 49 }



--- *****************************************************
---     LEAF for the lineEdfaRxpwrMeas article
--- *****************************************************

pmoabphcsMesrlineEdfaRxpwrMeas OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Rx Power :This OID gives 
        the receive power value of the
         Booster Optical Module (Power
         =(AV-32768)*0,005) (Unit = dBm) 
         <Help>  This measure gives the 
        Rx optical power of the Booster
        "
	  ::= { pmoabphcsMesrLine 50 }



--- *****************************************************
---     LEAF for the lineEdfaGainMeas article
--- *****************************************************

pmoabphcsMesrlineEdfaGainMeas OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Gain Target :This OID
         gives the gain value of the Booster 
        Module  (Gain =(AV-32768)*0,005) 
        (Unit = dB)  <Help>  This information 
        gives the target gain of the amplifier 
        for optimal performance
        "
	  ::= { pmoabphcsMesrLine 51 }



--- *****************************************************
---     LEAF for the lineOscSpanLoss article
--- *****************************************************

pmoabphcsMesrlineOscSpanLoss OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Input Span Loss :This
         OID indicates the attenuation
         of the span connected to the Booster 
        input (Power =(AV-32768)*0,005) 
         (Unit = dB) <Help> This measure 
        indicates the attenuation of the 
        span connected to the Booster input
        "
	  ::= { pmoabphcsMesrLine 52 }



--- *****************************************************
---     LEAF for the lineOscSpanLossRef article
--- *****************************************************

pmoabphcsMesrlineOscSpanLossRef OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Input Span Loss Ref :This 
        OID indicates the referenced attenuation 
        of the span connected to the Booster 
        input (Used to monitor the variation 
        of the span loss) (Power =(AV-32768)*0,005) 
         (Unit = dB) <Help> This measure 
        indicates the referenced attenuation 
        of the span connected to the Booster 
        input (Used to monitor the variation 
        of the span loss)
        "
	  ::= { pmoabphcsMesrLine 53 }



--- *****************************************************
---     LEAF for the lineCorrectedGain article
--- *****************************************************

pmoabphcsMesrlineCorrectedGain OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Gain :This OID gives the 
        gain value of the Booster Module 
        corrected by the ASE compensation 
        mechanism (Gain =(AV-32768)*0,005) 
        (Unit = dB)   <Help>  This measure 
        gives the effective gain of the 
        amplifier
        "
	  ::= { pmoabphcsMesrLine 54 }



--- *****************************************************
---     LEAF for the lineMsaInputPower article
--- *****************************************************

pmoabphcsMesrlineMsaInputPower OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster MSA Rx Power :This OID 
        indicates the input power of the 
        Mid Stage Access of the Booster 
        (Power =(AV-32768)*0,005) (Unit 
        = dBm)   <Help> This measure indicates 
        the input power of the Mid Stage 
        Access of the Booster
        "
	  ::= { pmoabphcsMesrLine 55 }



--- *****************************************************
---     LEAF for the lineMsaOutputPower article
--- *****************************************************

pmoabphcsMesrlineMsaOutputPower OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster MSA Tx Power :This OID 
        indicates the output power of the 
        Mid Stage Access of the Booster 
        (Power =(AV-32768)*0,005) (Unit 
        = dBm)   <Help> This measure indicates 
        the output power of the Mid Stage 
        Access of the Booster
        "
	  ::= { pmoabphcsMesrLine 56 }



--- *****************************************************
---     LEAF for the lineMsaAttenuation article
--- *****************************************************

pmoabphcsMesrlineMsaAttenuation OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster MSA Attenuation :This
         OID indicates the attenuation
         applied on the Mid Stage Access 
        of the Booster (Attenuation =(AV-32768)*0,005) 
        (Unit = dB)   <Help> This measure 
        indicates the attenuation applied 
        on the Mid Stage Access of the
         Booster
        "
	  ::= { pmoabphcsMesrLine 57 }



--- *****************************************************
---     LEAF for the lineMsaAttenuationRef article
--- *****************************************************

pmoabphcsMesrlineMsaAttenuationRef OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster MSA Attenuation Ref :This 
        OID indicates the reference attenuation 
        stored for the Mid Stage Access 
        of the Booster (Used to monitor 
        the variation of this attenuation) 
        (Attenuation =(AV-32768)*0,005) 
        (Unit = dB)   <Help> This measure 
        indicates the reference attenuation 
        stored for the Mid Stage Access 
        of the Booster (Used to monitor 
        the variation of this attenuation)
        "
	  ::= { pmoabphcsMesrLine 58 }



--- *********************************************************
---     TABLE for the pmoabphcsMesrlineOscTxPower articles
--- *********************************************************

pmoabphcsMesrlineOscTxPowerTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PmoabphcsMesrlineOscTxPowerEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pmoabphcsMesrlineOscTxPower 
        Article
        "
	::= { pmoabphcsMesrLine 64 }


pmoabphcsMesrlineOscTxPowerEntry OBJECT-TYPE
	SYNTAX PmoabphcsMesrlineOscTxPowerEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pmoabphcsMesrlineOscTxPower 
        table
        "
	INDEX   { pmoabphcsMesrlineOscTxPowerIndex }
	::= { pmoabphcsMesrlineOscTxPowerTable 1 }


PmoabphcsMesrlineOscTxPowerEntry ::=
	SEQUENCE {
	pmoabphcsMesrlineOscTxPowerIndex
		INTEGER,
	pmoabphcsMesrlineOscTxPowerPortn
		INTEGER 
	}


pmoabphcsMesrlineOscTxPowerIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pmoabphcsMesrlineOscTxPower 
        table
        "
	::= { pmoabphcsMesrlineOscTxPowerEntry 1 }


pmoabphcsMesrlineOscTxPowerPortn OBJECT-TYPE
	SYNTAX  INTEGER (0..65535)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        OSC Tx Power :This OID indicates 
        the output power of the OSC (Power 
        =(AV-32768)*0,005) (Unit = dBm) 
         <Help>  This measure indicates 
        the output power of the OSC
        "
	::= { pmoabphcsMesrlineOscTxPowerEntry 2 }


--- *********************************************************
---     TABLE for the pmoabphcsMesrlineOscRxPower articles
--- *********************************************************

pmoabphcsMesrlineOscRxPowerTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PmoabphcsMesrlineOscRxPowerEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pmoabphcsMesrlineOscRxPower 
        Article
        "
	::= { pmoabphcsMesrLine 65 }


pmoabphcsMesrlineOscRxPowerEntry OBJECT-TYPE
	SYNTAX PmoabphcsMesrlineOscRxPowerEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pmoabphcsMesrlineOscRxPower 
        table
        "
	INDEX   { pmoabphcsMesrlineOscRxPowerIndex }
	::= { pmoabphcsMesrlineOscRxPowerTable 1 }


PmoabphcsMesrlineOscRxPowerEntry ::=
	SEQUENCE {
	pmoabphcsMesrlineOscRxPowerIndex
		INTEGER,
	pmoabphcsMesrlineOscRxPowerPortn
		INTEGER 
	}


pmoabphcsMesrlineOscRxPowerIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pmoabphcsMesrlineOscRxPower 
        table
        "
	::= { pmoabphcsMesrlineOscRxPowerEntry 1 }


pmoabphcsMesrlineOscRxPowerPortn OBJECT-TYPE
	SYNTAX  INTEGER (0..65535)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        OSC Rx Power :This OID indicates 
        the input power of the OSC (Power 
        =(AV-32768)*0,005) (Unit = dBm) 
         <Help>  This measure indicates 
        the input power of the OSC
        "
	::= { pmoabphcsMesrlineOscRxPowerEntry 2 }


--- *****************************************************
---     LEAF for the tempMeas article
--- *****************************************************

pmoabphcsMesrtempMeas OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Module Temperature :This OID gives 
        the temperature of the PM  (Temperature 
        =AV/256) (Unit = C)  <Help>  This 
        measure gives the temperature of 
        the module
        "
	  ::= { pmoabphcsMesrOther 80 }








--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     CONFIG
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the table Group noValue
--- *****************************************************

pmoabphcsCfgNoValue OBJECT IDENTIFIER ::= { pmoabphcsConfig 1 }



--- *****************************************************
---     LEAF for the table 2111
--- *****************************************************

pmoabphcstableclientStartup OBJECT IDENTIFIER ::= { pmoabphcsCfgNoValue 1 }



pmoabphcsCfgclientEdfaLaserCtrl OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Client Laser 
        :This OID configures the default 
        initialisation settings on the
         client laser.
        "
	  ::= { pmoabphcstableclientStartup 2 }



pmoabphcsCfgclientEdfaLaserMode OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Client mode 
        :This OID configures the default 
        mode on the client amplifier.
        "
	  ::= { pmoabphcstableclientStartup 3 }



pmoabphcsCfgclientGainValue OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Client Gain 
        :This OID configures the default 
        gain on the client amplifier.
        "
	  ::= { pmoabphcstableclientStartup 4 }



pmoabphcsCfgclientTiltValue OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Client Tilt 
        :This OID configures the default 
        tilt on the client amplifier.
        "
	  ::= { pmoabphcstableclientStartup 5 }



pmoabphcsCfgclientMsaLoss OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Client MSA 
        :This OID configures the default 
        MSA value on the client amplifier.
        "
	  ::= { pmoabphcstableclientStartup 6 }



pmoabphcsCfgclientOutputPowerValue OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Client Output 
        power :This OID configures the
         default Output power value on
         the client amplifier.
        "
	  ::= { pmoabphcstableclientStartup 7 }



pmoabphcsCfgclientAseCompensation OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Client ASE 
        :This OID configures the default 
        ASE compensation value on the client 
        amplifier.
        "
	  ::= { pmoabphcstableclientStartup 8 }



--- *****************************************************
---     LEAF for the table Group lineStartUp
--- *****************************************************

pmoabphcsCfgLineStartUp OBJECT IDENTIFIER ::= { pmoabphcsConfig 2 }



--- *****************************************************
---     LEAF for the table 2191
--- *****************************************************

pmoabphcstablelineStartup OBJECT IDENTIFIER ::= { pmoabphcsCfgLineStartUp 1 }



pmoabphcsCfglineEdfaLaserCtrl OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Line Laser 
        :This OID configures the default 
        initialisation settings on the
         line laser.
        "
	  ::= { pmoabphcstablelineStartup 2 }



pmoabphcsCfglineEdfaLaserMode OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Line mode
         :This OID configures the default 
        mode on the line amplifier.
        "
	  ::= { pmoabphcstablelineStartup 3 }



pmoabphcsCfglineGainValue OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Line Gain
         :This OID configures the default 
        gain on the line amplifier.
        "
	  ::= { pmoabphcstablelineStartup 4 }



pmoabphcsCfglineTiltValue OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Line Tilt
         :This OID configures the default 
        tilt on the line amplifier.
        "
	  ::= { pmoabphcstablelineStartup 5 }



pmoabphcsCfglineMsaLoss OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Line MSA :This 
        OID configures the default MSA
         value on the line amplifier.
        "
	  ::= { pmoabphcstablelineStartup 6 }



pmoabphcsCfglineOutputPowerValue OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Line Output 
        power :This OID configures the
         default Output power value on
         the line amplifier.
        "
	  ::= { pmoabphcstablelineStartup 7 }



pmoabphcsCfglineAseCompensation OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Line ASE :This 
        OID configures the default ASE
         compensation value on the line 
        amplifier.
        "
	  ::= { pmoabphcstablelineStartup 8 }



pmoabphcsCfgaprMode OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default setting on module :This 
        OID configures the default mode 
        on the APR
        "
	  ::= { pmoabphcstablelineStartup 11 }



--- *****************************************************
---     LEAF for the table Group clientSupvStartUp
--- *****************************************************

pmoabphcsCfgClientSupvStartUp OBJECT IDENTIFIER ::= { pmoabphcsConfig 3 }



--- *****************************************************
---     LEAF for the table 2192
--- *****************************************************

pmoabphcsCfgLineStartupTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PmoabphcsCfgLineStartupEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pmoabphcsCfgClientSupvStartUp 1 }


pmoabphcsCfgLineStartupEntry OBJECT-TYPE
	SYNTAX PmoabphcsCfgLineStartupEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the clientSupvStartUp 
        table
        "
	INDEX   { pmoabphcsCfgLineStartupIndex }
	::= { pmoabphcsCfgLineStartupTable 1 }


PmoabphcsCfgLineStartupEntry ::=
	SEQUENCE {
	pmoabphcsCfgLineStartupIndex
		INTEGER,
	pmoabphcsCfgLineOscLaserCtrlPortn
		Unsigned32,
	pmoabphcsCfgLineOscOosPortn
		Unsigned32,
	pmoabphcsCfgLineOscSpanLengthPortn
		Unsigned32,
	pmoabphcsCfgLineOscCorrectionFactorPortn
		Unsigned32
	}


pmoabphcsCfgLineStartupIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the lineStartup 
        table
        "
	::= { pmoabphcsCfgLineStartupEntry 1 }


pmoabphcsCfgLineOscLaserCtrlPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default Settings on OSC Laser
         :This OID configures the default 
        initialisation settings on the
         OSC
        "
	::= { pmoabphcsCfgLineStartupEntry 3 }


pmoabphcsCfgLineOscOosPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default Settings on OSC mode :This 
        OID configures the default mode 
        on the OSC
        "
	::= { pmoabphcsCfgLineStartupEntry 4 }


pmoabphcsCfgLineOscSpanLengthPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default Settings on OSC span length 
        :This OID defines the length of 
        the span connected on the OSC port
        "
	::= { pmoabphcsCfgLineStartupEntry 5 }


pmoabphcsCfgLineOscCorrectionFactorPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default Settings on OSC attenuation 
        corrector factor :This OID defines 
        the correction factor to apply
         on the span attenuation measure 
        on the OSC Channel (1510) before 
        configuring the EDFA gain.
        "
	::= { pmoabphcsCfgLineStartupEntry 6 }


--- *****************************************************
---     LEAF for the table Group labels
--- *****************************************************

pmoabphcsCfgLabels OBJECT IDENTIFIER ::= { pmoabphcsConfig 4 }



--- *****************************************************
---     LEAF for the table NO_VALUE
--- *****************************************************

pmoabphcsCfgLabelclientTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PmoabphcsCfgLabelclientEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pmoabphcsCfgLabels 1 }


pmoabphcsCfgLabelclientEntry OBJECT-TYPE
	SYNTAX PmoabphcsCfgLabelclientEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the labels
         table
        "
	INDEX   { pmoabphcsCfgLabelclientIndex }
	::= { pmoabphcsCfgLabelclientTable 1 }


PmoabphcsCfgLabelclientEntry ::=
	SEQUENCE {
	pmoabphcsCfgLabelclientIndex
		INTEGER,
	pmoabphcsCfgLabelclientPortn
		DisplayString
	}


pmoabphcsCfgLabelclientIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the labelclient 
        table
        "
	::= { pmoabphcsCfgLabelclientEntry 1 }


pmoabphcsCfgLabelclientPortn OBJECT-TYPE
	SYNTAX  DisplayString( SIZE(1..16))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default settings on the label
         of the Ports :These registers
         configures the default initialisation 
        settings of the labels of the ports.
        "
	::= { pmoabphcsCfgLabelclientEntry 3 }


--- *****************************************************
---     LEAF for the table NO_VALUE
--- *****************************************************

pmoabphcsCfgLabellineTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PmoabphcsCfgLabellineEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pmoabphcsCfgLabels 2 }


pmoabphcsCfgLabellineEntry OBJECT-TYPE
	SYNTAX PmoabphcsCfgLabellineEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the labels
         table
        "
	INDEX   { pmoabphcsCfgLabellineIndex }
	::= { pmoabphcsCfgLabellineTable 1 }


PmoabphcsCfgLabellineEntry ::=
	SEQUENCE {
	pmoabphcsCfgLabellineIndex
		INTEGER,
	pmoabphcsCfgLabellinePortn
		DisplayString
	}


pmoabphcsCfgLabellineIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the labelline 
        table
        "
	::= { pmoabphcsCfgLabellineEntry 1 }


pmoabphcsCfgLabellinePortn OBJECT-TYPE
	SYNTAX  DisplayString( SIZE(1..16))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default settings on the label
         of the lines :These registers
         configures the default initialisation 
        settings of the labels of the lines.
        "
	::= { pmoabphcsCfgLabellineEntry 3 }



pmoabphcsCfgWriteConfiguration  OBJECT-TYPE
	SYNTAX EkiOnOff
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
	"Write configuration to module:This OID 
	 writes the complete configuration to the module"
	::= { pmoabphcsConfig 257 }






--- *****************************************************
---     TRAP OBJECTS
--- *****************************************************

pmoabphcstrapBoardNumber OBJECT-TYPE
	SYNTAX INTEGER(1..64)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
	"Last module which generates a trap"
	::= { pmoabphcstraps 4 }







--- *****************************************************
---     GLOBAL TRAPS
--- *****************************************************

pmoabphcsLineTrapCritGoesOn NOTIFICATION-TYPE
	OBJECTS {pmoabphcsAlmLineFail, pmoabphcsAlmLineHwFail, pmoabphcstrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOABPHCS Line Fail ON"
	--&ACTIONS     { log, critical }
	--&MATCH       { pmoabphcsAlmLineFail "on", pmoabphcsAlmLineHwFail "*", pmoabphcstrapBoardNumber "$3"}
	--&MESG        "Critical Alarm appears on Pre-Amp input or Booster Output of PMOABPHCS in slot $3 ($A)"
	
	--&FILTNAME    "PMOABPHCS Line HW Fail ON (Hidden)"
	--&ACTIONS     { info }
	--&MATCH       { pmoabphcsAlmLineFail "*", pmoabphcsAlmLineHwFail "on", pmoabphcstrapBoardNumber "$3"}
	--&MESG        "Critical Alarm appears on Pre-Amp input or Booster Output of PMOABPHCS in slot $3 ($A)"
	DESCRIPTION "Critical Line default is activated"
	::= { pmoabphcstraps 34 }

pmoabphcsLineTrapCritGoesOff NOTIFICATION-TYPE
	OBJECTS {pmoabphcsAlmLineFail, pmoabphcsAlmLineHwFail, pmoabphcstrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOABPHCS Line Fail OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      {"PMOABPHCS Line Fail ON"}
	--&MATCH       { pmoabphcsAlmLineFail "on", pmoabphcsAlmLineHwFail "*", pmoabphcstrapBoardNumber "$3"}
	--&MESG        "Critical Alarm disappears on Pre-Amp input or Booster Output of PMOABPHCS in slot $3 ($A)"
	
	--&FILTNAME    "PMOABPHCS Line HW Fail OFF (Hidden)"
	--&ACTIONS     { info }
	--&MATCH       { pmoabphcsAlmLineFail "*", pmoabphcsAlmLineHwFail "on", pmoabphcstrapBoardNumber "$3"}
	--&MESG        "Critical Alarm disappears on Pre-Amp input or Booster Output of PMOABPHCS in slot $3 ($A)"
	DESCRIPTION "Critical Line default disappeared"
	::= { pmoabphcstraps 35 }






--- *****************************************************
---     PORTS TRAPS
--- *****************************************************

pmoabphcsClientTrapCritGoesOn NOTIFICATION-TYPE
	OBJECTS {pmoabphcsAlmClientFail, pmoabphcsAlmClientHwFail, pmoabphcstrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOABPHCS Client Fail ON"
	--&ACTIONS     { log, critical }
	--&MATCH       { pmoabphcsAlmClientFail "on", pmoabphcsAlmClientHwFail "*", pmoabphcstrapBoardNumber "$3"}
	--&MESG        "Critical Alarm appears on Booster input or Pre-Amp Output of PMOABPHCS in slot $3 ($A)"
	
	--&FILTNAME    "PMOABPHCS Client HW Fail ON (Hidden)"
	--&ACTIONS     { info }
	--&MATCH       { pmoabphcsAlmClientFail "*", pmoabphcsAlmClientHwFail "on", pmoabphcstrapBoardNumber "$3"}
	--&MESG        "Critical Alarm appears on Booster input or Pre-Amp Output of PMOABPHCS in slot $3 ($A)"
	DESCRIPTION "Critical client default is activated"
	::= { pmoabphcstraps 44 }

pmoabphcsClientTrapCritGoesOff NOTIFICATION-TYPE
	OBJECTS {pmoabphcsAlmClientFail, pmoabphcsAlmClientHwFail, pmoabphcstrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOABPHCS Client Fail OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      {"PMOABPHCS Client Fail ON"}
	--&MATCH       { pmoabphcsAlmClientFail "on", pmoabphcsAlmClientHwFail "*", pmoabphcstrapBoardNumber "$3"}
	--&MESG        "Critical Alarm disappears on Booster input or Pre-Amp Output of PMOABPHCS in slot $3 ($A)"
	
	--&FILTNAME    "PMOABPHCS Client HW Fail OFF (Hidden)"
	--&ACTIONS     { info }
	--&MATCH       { pmoabphcsAlmClientFail "*", pmoabphcsAlmClientHwFail "on", pmoabphcstrapBoardNumber "$3"}
	--&MESG        "Critical Alarm disappears on Booster input or Pre-Amp Output of PMOABPHCS in slot $3 ($A)"
	DESCRIPTION "Critical client default disappeared"
	::= { pmoabphcstraps 45 }






--- *****************************************************
---     HW TRAPS
--- *****************************************************

pmoabphcsPowerTrapUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pmoabphcsAlmDefFuseB, pmoabphcsAlmDefFuseA , pmoabphcstrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOABPHCS Fuse A Fail ON"
	--&ACTIONS     { log, major }
	--&MATCH       { pmoabphcsAlmDefFuseB "*", pmoabphcsAlmDefFuseA "on", pmoabphcstrapBoardNumber "$3"}
	--&MESG        "Power Input A Fail on PMOABPHCS in Slot $3 ($A)"

	--&FILTNAME    "PMOABPHCS Fuse B Fail ON"
	--&ACTIONS     { log, major }
	--&MATCH       { pmoabphcsAlmDefFuseB "on", pmoabphcsAlmDefFuseA "*", pmoabphcstrapBoardNumber "$3"}
	--&MESG        "Power Input B Fail on PMOABPHCS in Slot $3 ($A)"
	DESCRIPTION "Urgent power supply default is activated"
	::= { pmoabphcstraps 50 }
pmoabphcsPowerTrapUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pmoabphcsAlmDefFuseB, pmoabphcsAlmDefFuseA , pmoabphcstrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOABPHCS Fuse A&B Fail OFF"
	--&ACTIONS     { log, normal}
	--&CLEARS      { "PMOABPHCS Fuse A Fail ON", "PMOABPHCS Fuse B Fail ON" }
	--&MATCH       { pmoabphcsAlmDefFuseB "on", pmoabphcsAlmDefFuseA "on", pmoabphcstrapBoardNumber "$3"}
	--&MESG        "Power Inputs A and B Present on PMOABPHCS in Slot $3 ($A)"
	DESCRIPTION "Urgent power supply default disappeared"
	::= { pmoabphcstraps 51 }






END