-- EKINOPS-Pme1008.TXT:  MIB
--
--MIB Part Number:3MI00041AAAA
--MIB Version:03
--
-- Copyright (c) 2016 by Ekinops
-- All rights reserved.
-- 
-- *****************************************************************

EKINOPS-Pme1008-MIB DEFINITIONS ::= BEGIN

IMPORTS
	ekinops,
	EkiState,
	EkiOnOff,
	EkiMode,
	EkiProtocol,
	EkiApiState,
	EkiSynchroMode,
	EkiMeasureType
			FROM EKINOPS-MIB
        MODULE-IDENTITY,
        OBJECT-TYPE,
        NOTIFICATION-TYPE,
	Unsigned32,
	Integer32,
	Counter32,
	IpAddress                
        		FROM SNMPv2-SMI
 	TEXTUAL-CONVENTION,
	DisplayString
                FROM SNMPv2-TC;

modulePme1008 MODULE-IDENTITY
        LAST-UPDATED "201609050000Z"
        ORGANIZATION "Ekinops"
        CONTACT-INFO
         "Ekinops

          3, rue Blaise Pascal
          F-22300 Lannion / FRANCE

          Tel : +33 (0)2 96 05 00 30
          Fax : +33 (0)2 96 48 62 39

          E-mail: support@ekinops.fr"
        DESCRIPTION
          "Creation."

	REVISION "201609050000Z"
	DESCRIPTION
	  "Creation for PME1008"
        ::= { ekinops 79 }



--- *****************************************************
---     LEAF LEVEL 2
--- *****************************************************


pme1008alarms OBJECT IDENTIFIER ::= { modulePme1008 2 }	
pme1008AlmOther OBJECT IDENTIFIER ::= { pme1008alarms 1 }
pme1008AlmOtherNurg OBJECT IDENTIFIER ::= { pme1008AlmOther 1 }
pme1008AlmOtherUrg OBJECT IDENTIFIER ::= { pme1008AlmOther 2 }
pme1008AlmOtherCrit OBJECT IDENTIFIER ::= { pme1008AlmOther 3 }

pme1008AlmClient OBJECT IDENTIFIER ::= { pme1008alarms 2 }
pme1008AlmClientNurg OBJECT IDENTIFIER ::= { pme1008AlmClient 1 }
pme1008AlmClientUrg OBJECT IDENTIFIER ::= { pme1008AlmClient 2 }
pme1008AlmClientCrit OBJECT IDENTIFIER ::= { pme1008AlmClient 3 }
	
pme1008AlmLine OBJECT IDENTIFIER ::= { pme1008alarms 3 }
pme1008AlmLineNurg OBJECT IDENTIFIER ::= { pme1008AlmLine 1 }
pme1008AlmLineUrg OBJECT IDENTIFIER ::= { pme1008AlmLine 2 }
pme1008AlmLineCrit OBJECT IDENTIFIER ::= { pme1008AlmLine 3 }





pme1008measures OBJECT IDENTIFIER ::= { modulePme1008 3 }	
pme1008MesrOther OBJECT IDENTIFIER ::= { pme1008measures 1 }	
pme1008MesrClient OBJECT IDENTIFIER ::= { pme1008measures 2 }	
pme1008MesrLine OBJECT IDENTIFIER ::= { pme1008measures 3 }	




pme1008counters OBJECT IDENTIFIER ::= { modulePme1008 4 }
pme1008CntOther OBJECT IDENTIFIER ::= { pme1008counters 1 }
pme1008CntClient OBJECT IDENTIFIER ::= { pme1008counters 2 }
pme1008CntLine OBJECT IDENTIFIER ::= { pme1008counters 3 }


pme1008controlsWrite OBJECT IDENTIFIER ::= { modulePme1008 6 }
pme1008CtrlOther OBJECT IDENTIFIER ::= { pme1008controlsWrite 1 }
pme1008CtrlClient OBJECT IDENTIFIER ::= { pme1008controlsWrite 2 }
pme1008CtrlLine OBJECT IDENTIFIER ::= { pme1008controlsWrite 3 }

pme1008ri OBJECT IDENTIFIER ::= { modulePme1008 7 }
pme1008riTable OBJECT IDENTIFIER ::= { pme1008ri 1 }

pme1008download OBJECT IDENTIFIER ::= { modulePme1008 8 }
pme1008DwlOther OBJECT IDENTIFIER ::= { pme1008download 1 }
pme1008DwlClient OBJECT IDENTIFIER ::= { pme1008download 2 }
pme1008DwlLine OBJECT IDENTIFIER ::= { pme1008download 3 }


pme1008Config OBJECT IDENTIFIER ::= { modulePme1008 9 }

pme1008traps OBJECT IDENTIFIER ::= { modulePme1008 10 }



pme1008Monitoring OBJECT IDENTIFIER ::= { modulePme1008 11}

pme1008MonOther OBJECT IDENTIFIER ::= { pme1008Monitoring 1 }
pme1008MonRmon OBJECT IDENTIFIER ::= { pme1008MonOther 3 }

pme1008MonClient OBJECT IDENTIFIER ::= { pme1008Monitoring 2 }
pme1008MonClientRmonCounter OBJECT IDENTIFIER ::= { pme1008MonClient 4 }


--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     TEXTUAL-CONVENTION
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************


Pme1008OtxGrid ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION "Different grids on client and line ports"
    SYNTAX INTEGER {
		otxgrid200(200),
		otxgrid100(100),
		otxgrid50(50)
           }


Pme1008DccMode ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION "Mode for DCC"
    SYNTAX INTEGER {
		dccNo(0),
		dccLine1(1),
		dccLine2(2)
           }

Pme1008LineChannel ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION "Channel selection on transceiver Line ports"
    SYNTAX INTEGER


Pme1008Odu2SapiMode ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION "Mode for SAPI-DAPI"
    SYNTAX INTEGER {
		off(0),
		sapi(1),
		dapi(2),
		sapidapi(3)
           }

Pme1008Otu2SapiMode ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION "Mode for SAPI-DAPI"
    SYNTAX INTEGER {
		off(0),
		sapi(1),
		dapi(2),
		sapidapi(3)
           }

Pme1008ClientProtocol ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION "Different values on the protocol on the client ports"
    SYNTAX INTEGER {
		protocolclientvalue2(2),
		protocolclientvalue3(3),
		protocolclientvalue4(4),
		protocolclientvalue6(6),
		protocolclientvalue7(7)
           }


--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     REMOTE INVENTORY
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************

pme1008RinvReloadInventory OBJECT-TYPE
  SYNTAX EkiOnOff
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
        "Reload the inventory: This OID triggers an 
         inventory reload."
  ::= { pme1008ri 2 }

pme1008RinvHwPlatform OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
        "HW platform description: This OID contains the 
         description of the Hardware platform."
  ::= { pme1008ri 3 }
  
pme1008RinvModulePlatform OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
        "Module platform description: This OID contains the 
         description of the Module."
  ::= { pme1008ri 4 }
  
pme1008RinvSwPlatform OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
        "SW platform description: This OID contains the 
         description of the Software platform."
  ::= { pme1008ri 5 }
  
pme1008RinvGwPlatform OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
        "GW platform description: This OID contains the 
         description of the Gateware platform."
  ::= { pme1008ri 6 }


pme1008RinvSfpTable OBJECT-TYPE
      SYNTAX  SEQUENCE OF Pme1008RinvSfpEntry
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
              "List of the SFPs on the selected module"
      ::= { pme1008riTable 1 }

pme1008RinvSfpEntry OBJECT-TYPE
        SYNTAX  Pme1008RinvSfpEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
              "Row definition for the SFP table"
        INDEX   { pme1008RinvSfpIndex }
        ::= { pme1008RinvSfpTable 1 }
    


Pme1008RinvSfpEntry::=
        SEQUENCE {
          pme1008RinvSfpIndex 
              Integer32,
          pme1008Rinvsfp
              DisplayString
        }


    pme1008RinvSfpIndex OBJECT-TYPE
        SYNTAX  Integer32(1..16)
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
              "Index for SFP table"
        ::= { pme1008RinvSfpEntry 1 }


    pme1008Rinvsfp OBJECT-TYPE
        SYNTAX  DisplayString
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
              "Inventory for the SFP: This OID contains the inventory for the SFP"
        ::= { pme1008RinvSfpEntry 2 }




pme1008RinvLineTable OBJECT-TYPE
      SYNTAX  SEQUENCE OF Pme1008RinvLineEntry
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
              "List of the SFPs on the selected module"
      ::= { pme1008riTable 2 }

pme1008RinvLineEntry OBJECT-TYPE
        SYNTAX  Pme1008RinvLineEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
              "Row definition for the SFP table"
        INDEX   { pme1008RinvLineIndex }
        ::= { pme1008RinvLineTable 1 }
    


Pme1008RinvLineEntry::=
        SEQUENCE {
          pme1008RinvLineIndex 
              Integer32,
          pme1008RinvxfpLine
              DisplayString
        }


    pme1008RinvLineIndex OBJECT-TYPE
        SYNTAX  Integer32(1..16)
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
              "Index for SFP table"
        ::= { pme1008RinvLineEntry 1 }


    pme1008RinvxfpLine OBJECT-TYPE
        SYNTAX  DisplayString
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
              "Inventory for the XFP: This OID contains the inventory for the XFP"
        ::= { pme1008RinvLineEntry 2 }









--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     ALARMS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the synthAlm0 article
--- *****************************************************
pme1008AlmsynthAlm0 OBJECT IDENTIFIER ::= { pme1008AlmOtherCrit 0 }




pme1008AlmDefFuseB OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Fuse B Fail :This OID indicates 
        that the fuse of the power input 
        B is in fail condition <Help> Status 
        of the Fuse B <Condtype> DEF_FUSE_B 
        <Probcause> powerProblem (36) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pme1008AlmsynthAlm0 16 }



pme1008AlmDefFuseA OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Fuse A Fail :This OID indicates 
        that the fuse of the power input 
        A is in fail condition <Help> Status 
        of the Fuse A <Condtype> DEF_FUSE_A 
        <Probcause> powerProblem (36) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pme1008AlmsynthAlm0 15 }



pme1008AlmModGlobFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Module Failure :This OID is set 
        on detection of a failure originating 
        from the RM <Help> This alarm is 
        set on detection of a failure originating 
        from the equipment <Condtype> MOD_GLOB_FAIL 
        <Probcause> other (1) <Alarmtype> 
        synthesisAlarm (12)  <Polarity> 
        (2) 
        "
	  ::= { pme1008AlmsynthAlm0 9 }



--- *****************************************************
---     LEAF for the synthAlm2 article
--- *****************************************************
pme1008AlmsynthAlm2 OBJECT IDENTIFIER ::= { pme1008AlmOtherNurg 2 }




pme1008AlmCorrelatOff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Not Used :This OID, when set,
         indicates that alarm correlation 
        is not being performed. <Condtype> 
        CORRELAT_OFF <Probcause> informationalStatus(1000) 
        <Alarmtype> other (1) <Polarity> 
        (2) 
        "
	  ::= { pme1008AlmsynthAlm2 4 }



pme1008AlmConfTableLoad OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        PM Configuration Load :This OID 
         is at 1 during the loading of
         configuration tables in the modules 
        RAM. <Condtype> CONF_TABLE_LOAD 
        <Probcause> informationalStatus(1000) 
        <Alarmtype> other (1) <Polarity> 
        (2) 
        "
	  ::= { pme1008AlmsynthAlm2 3 }



pme1008AlmInvUpload OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Inventory Upload :This OID is
         at 1 during the uploading of PM 
        inventory information. <Condtype> 
        INV_UPLOAD <Probcause> informationalStatus(1000) 
        <Alarmtype> other (1) <Polarity> 
        (2) 
        "
	  ::= { pme1008AlmsynthAlm2 2 }



pme1008AlmConfTableSave OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        PM Configuration Save :This OID 
        is at 1 during the saving of a
         new configuration table in the 
        module Flash memory. <Condtype> 
        CONF_TABLE_SAVE <Probcause> informationalStatus(1000) 
        <Alarmtype> other (1) <Polarity> 
        (2) 
        "
	  ::= { pme1008AlmsynthAlm2 1 }



--- *********************************************************
---     TABLE for the pme1008AlmsynthAlmPort articles
--- *********************************************************

pme1008AlmsynthAlmPortTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008AlmsynthAlmPortEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008AlmsynthAlmPort 
        Article
        "
	::= { pme1008AlmClientCrit 8 }


pme1008AlmsynthAlmPortEntry OBJECT-TYPE
	SYNTAX Pme1008AlmsynthAlmPortEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008AlmsynthAlmPort 
        table
        "
	INDEX   { pme1008AlmsynthAlmPortIndex }
	::= { pme1008AlmsynthAlmPortTable 1 }


Pme1008AlmsynthAlmPortEntry ::=
	SEQUENCE {
	pme1008AlmsynthAlmPortIndex
		INTEGER,
	pme1008AlmUpCsfPortn
		EkiOnOff,
	pme1008AlmFailAccPortn
		EkiOnOff,
	pme1008AlmSfpDdmAlmPortn
		EkiOnOff,
	pme1008AlmSfpDdmWarningPortn
		EkiOnOff,
	pme1008AlmDwCaisPortn
		EkiOnOff,
	pme1008AlmClientRemoteOosPortn
		EkiOnOff,
	pme1008AlmClientLocalOosPortn
		EkiOnOff,
	pme1008AlmDwLsdPortn
		EkiOnOff,
	pme1008AlmHwFailAccPortn
		EkiOnOff,
	pme1008AlmDdmAbsentPortn
		EkiOnOff,
	pme1008AlmSfpAbsentPortn
		EkiOnOff
	}


pme1008AlmsynthAlmPortIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008AlmsynthAlmPort 
        table
        "
	::= { pme1008AlmsynthAlmPortEntry 1 }


pme1008AlmUpCsfPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Signal Fail Inserted :This 
        OID indicates a CSF has been inserted 
        in the upstream client port. <Help> 
        This status indicates if a Client 
        Signal Fail is currently inserted 
        on the line signal for this client 
        port <Condtype> UP_CSF_1 <Probcause> 
        informationalStatus(1000) <Alarmtype> 
        other (1) <Polarity> (2) 
        "
	::= { pme1008AlmsynthAlmPortEntry 17 }


pme1008AlmFailAccPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Access Fail :This OID indicates 
        a failure on the Client port <Help> 
        This alarm indicates a failure
         on the Client port <Condtype>
         FAIL_ACC_1 <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	::= { pme1008AlmsynthAlmPortEntry 13 }


pme1008AlmSfpDdmAlmPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Alarm On Client Trscv DDM :This 
        OID indicates an alarm is being 
        received from the Client Transceiver 
        DDM <Help> This alarm indicates 
        if a DDM Alarm has been detected 
        on the client transceiver <Condtype> 
        SFP_DDM_ALM_1 <Probcause> inputOutputDeviceError 
        (24) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	::= { pme1008AlmsynthAlmPortEntry 11 }


pme1008AlmSfpDdmWarningPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Warning On Client Trscv DDM :This 
        OID indicates a warning is being 
        received from the Client Transceiver 
        DDM <Help> This alarm indicates 
        if a DDM Warning has been detected 
        on the client transceiver <Condtype> 
        SFP_DDM_WARNING_1 <Probcause> inputOutputDeviceError 
        (24) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	::= { pme1008AlmsynthAlmPortEntry 10 }


pme1008AlmDwCaisPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client AIS Inserted :This OID
         indicates a CAIS has been inserted 
        on the output client port. <Help> 
        This status indicates if a Client 
        Alarm Indication Signal is currently 
        inserted on the client interface 
        <Condtype> DW_CAIS_1 <Probcause> 
        informationalStatus(1000) <Alarmtype> 
        other (1) <Polarity> (2) 
        "
	::= { pme1008AlmsynthAlmPortEntry 9 }


pme1008AlmClientRemoteOosPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Remote Client Port In Service
         :This OID indicates that the remote 
        Client port is In Service (1) or 
        Out of Service (2) <Help> This
         status indicates if the remote 
        client port is in service <Condtype> 
        CLIENT_REMOTE_OOS <Probcause> informationalStatus(1000) 
        <Alarmtype> other (1) <Polarity> 
        (2) 
        "
	::= { pme1008AlmsynthAlmPortEntry 8 }


pme1008AlmClientLocalOosPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Local Client Port In Service :This 
        OID indicates that the local Client 
        port is In Service (1) or Out of 
        Service (2) <Help> This status
         indicates if the local client
         port is in service <Condtype>
         CLIENT_LOCAL_OOS <Probcause> informationalStatus(1000) 
        <Alarmtype> other (1) <Polarity> 
        (2) 
        "
	::= { pme1008AlmsynthAlmPortEntry 7 }


pme1008AlmDwLsdPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client SFP Laser Shutdown :This 
        OID indicates the Client transceiver 
        laser is shutdown <Help> This status 
        indicates if the client transceiver 
        laser is shutdown <Condtype> DW_LSD_1 
        <Probcause> other (1) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	::= { pme1008AlmsynthAlmPortEntry 6 }


pme1008AlmHwFailAccPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client HW Fail :This OID indicates 
        a failure on client port, most
         probably caused by a HW issue. 
        <Help> This alarm indicates a failure 
        on client port, most probably caused 
        by a HW issue. <Condtype> HW_FAIL_ACC_1 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	::= { pme1008AlmsynthAlmPortEntry 5 }


pme1008AlmDdmAbsentPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        DDM Supported On Client Trscv
         :This OID indicates that the Client 
        transceiver supports the Digital 
        Diagnostic Monitoring function
         <Help> This status indicates if 
        the client transceiver includes 
        the DDM feature <Condtype> DDM_ABSENT_1 
        <Probcause> informationalStatus(1000) 
        <Alarmtype> other (1) <Polarity> 
        (2) 
        "
	::= { pme1008AlmsynthAlmPortEntry 3 }


pme1008AlmSfpAbsentPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client SFP Absent :This OID indicates 
        that the Transceiver is not present 
        in the client port. <Help> This 
        alarm indicates if the client transceiver 
        is not plugged <Condtype> SFP_ABSENT_1 
        <Probcause> inputOutputDeviceError 
        (24) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) <Event> ObjectCDINV
        "
	::= { pme1008AlmsynthAlmPortEntry 2 }


--- *********************************************************
---     TABLE for the pme1008AlmsynthAlmLine articles
--- *********************************************************

pme1008AlmsynthAlmLineTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008AlmsynthAlmLineEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008AlmsynthAlmLine 
        Article
        "
	::= { pme1008AlmLineCrit 24 }


pme1008AlmsynthAlmLineEntry OBJECT-TYPE
	SYNTAX Pme1008AlmsynthAlmLineEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008AlmsynthAlmLine 
        table
        "
	INDEX   { pme1008AlmsynthAlmLineIndex }
	::= { pme1008AlmsynthAlmLineTable 1 }


Pme1008AlmsynthAlmLineEntry ::=
	SEQUENCE {
	pme1008AlmsynthAlmLineIndex
		INTEGER,
	pme1008AlmLineFailPortn
		EkiOnOff,
	pme1008AlmLineDdmAlmPortn
		EkiOnOff,
	pme1008AlmLineDdmWarningPortn
		EkiOnOff,
	pme1008AlmUpRdiInsPortn
		EkiOnOff,
	pme1008AlmLineLocalOosPortn
		EkiOnOff,
	pme1008AlmLineTxOffPortn
		EkiOnOff,
	pme1008AlmLineHwFailPortn
		EkiOnOff,
	pme1008AlmLineDdmAbsentPortn
		EkiOnOff,
	pme1008AlmLineSfpAbsentPortn
		EkiOnOff
	}


pme1008AlmsynthAlmLineIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008AlmsynthAlmLine 
        table
        "
	::= { pme1008AlmsynthAlmLineEntry 1 }


pme1008AlmLineFailPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Port Failure :This OID indicates 
        a failure on the line port <Help> 
        This alarm indicates a failure
         on the line port <Condtype> LINE_FAIL 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	::= { pme1008AlmsynthAlmLineEntry 13 }


pme1008AlmLineDdmAlmPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Alarm On Line Optical Module DDM 
        :This OID indicates an alarm is 
        present coming out of Line transceiver 
        DDM <Help> This alarm indicates 
        if a DDM Alarm has been detected 
        on the line transceiver <Condtype> 
        LINE_DDM_ALM <Probcause> inputOutputDeviceError 
        (24) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	::= { pme1008AlmsynthAlmLineEntry 11 }


pme1008AlmLineDdmWarningPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Warning On Line Optical Module 
        DDM :This OID indicates a warning 
        is present coming out of Line transceiver 
        DDM <Help> This alarm indicates 
        if a DDM Warning has been detected 
        on the line transceiver <Condtype> 
        LINE_DDM_WARNING <Probcause> inputOutputDeviceError 
        (24) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	::= { pme1008AlmsynthAlmLineEntry 10 }


pme1008AlmUpRdiInsPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        MS-RDI/L-RDI Inserted On Line
         :This OID indicates an upstream 
        MS-RDI/L-RDI has been inserted
         in the outgoing 10 Gb/s SDH/SONET 
        signal. <Help> This status indicates 
        if a MS-RDI/L-RDI is currently
         inserted on the line interface. 
        <Condtype> UP_RDI_INS <Probcause> 
        informationalStatus(1000) <Alarmtype> 
        other (1) <Polarity> (2) 
        "
	::= { pme1008AlmsynthAlmLineEntry 9 }


pme1008AlmLineLocalOosPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Port In Service :This OID 
        indicates that the Line port is 
        In Service (1) of Out or Service 
        (2) <Help> This status indicates 
        if the line port is in service
         <Condtype> LINE_LOCAL_OOS <Probcause> 
        informationalStatus(1000) <Alarmtype> 
        other (1) <Polarity> (2) 
        "
	::= { pme1008AlmsynthAlmLineEntry 7 }


pme1008AlmLineTxOffPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Optical Module Laser Shutdown 
        :This OID indicates the Line transceiver 
        laser is shutdown <Help> This status 
        indicates if the Line transceiver 
        laser is shutdown <Condtype> LINE_TX_OFF 
        <Probcause> other (1) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	::= { pme1008AlmsynthAlmLineEntry 6 }


pme1008AlmLineHwFailPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Port HW Failure :This OID 
        indicates a failure on line port, 
        most probably caused by a HW issue 
        <Help> This alarm indicates a failure 
        on line port, most probably caused 
        by a HW issue <Condtype> LINE_HW_FAIL 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	::= { pme1008AlmsynthAlmLineEntry 5 }


pme1008AlmLineDdmAbsentPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Optical Module Ready :This 
        OID indicates that the optical
         interface is not operational.
         <Help> This status indicates if 
        the line transceiver has been correctly 
        initialized <Condtype> LINE_DDM_ABSENT_1 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> other (1) <Polarity> 
        (2) 
        "
	::= { pme1008AlmsynthAlmLineEntry 3 }


pme1008AlmLineSfpAbsentPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Optical Module Absent :This 
        OID indicates that the line optical 
        interface is not present. <Help> 
        This alarm indicates if the line 
        transceiver is not plugged <Condtype> 
        LINE_SFP_ABSENT_1 <Probcause> inputOutputDeviceError 
        (24) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) <Event> ObjectCDINV
        "
	::= { pme1008AlmsynthAlmLineEntry 2 }


--- *********************************************************
---     TABLE for the pme1008AlmclientHostLaneFault articles
--- *********************************************************

pme1008AlmclientHostLaneFaultTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008AlmclientHostLaneFaultEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008AlmclientHostLaneFault 
        Article
        "
	::= { pme1008AlmClientUrg 88 }


pme1008AlmclientHostLaneFaultEntry OBJECT-TYPE
	SYNTAX Pme1008AlmclientHostLaneFaultEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008AlmclientHostLaneFault 
        table
        "
	INDEX   { pme1008AlmclientHostLaneFaultIndex }
	::= { pme1008AlmclientHostLaneFaultTable 1 }


Pme1008AlmclientHostLaneFaultEntry ::=
	SEQUENCE {
	pme1008AlmclientHostLaneFaultIndex
		INTEGER,
	pme1008AlmClientLaneTxFifoErrorPortn
		EkiOnOff,
	pme1008AlmClientCsfDetectedPortn
		EkiOnOff,
	pme1008AlmClientInputLossOfSigPortn
		EkiOnOff,
	pme1008AlmClientLossOfSyncPortn
		EkiOnOff
	}


pme1008AlmclientHostLaneFaultIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008AlmclientHostLaneFault 
        table
        "
	::= { pme1008AlmclientHostLaneFaultEntry 1 }


pme1008AlmClientLaneTxFifoErrorPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Tx FIFO Error :This OID 
        indicates a Tx FIFO Error on the 
        Client Trscv <Help> Alarm indicating 
        a Tx FIFO Error on the Client Trscv 
        <Condtype> CLIENT_LANE_TX_FIFO_ERROR 
        <Probcause> receiverFailure (42) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2)
        "
	::= { pme1008AlmclientHostLaneFaultEntry 11 }


pme1008AlmClientCsfDetectedPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Signal Fail Detected :This 
        OID indicates that a CSF has been 
        detected on client port in the
         downstream direction   <Help>
          This alarm indicates if a Client 
        Signal Fail has been detected in 
        the incoming line frame for this 
        client port <Condtype> CLIENT_CSF_DETECTED 
        <Probcause> receiveFailure (41) 
        <Alarmtype> other(1) <Polarity> 
        (2)
        "
	::= { pme1008AlmclientHostLaneFaultEntry 7 }


pme1008AlmClientInputLossOfSigPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Input Loss Of Signal :This 
        OID indicates a Loss of Signal
         is detected on the Client Trscv 
        <Help> Alarm indicating a Loss
         of Signal is detected on the Client 
        Trscv <Condtype> CLIENT_INPUT_LOSS_OF_SIG 
        <Probcause> receiveFailure (41) 
        <Alarmtype> physicalViolation (9) 
        <Polarity> (2) 
        "
	::= { pme1008AlmclientHostLaneFaultEntry 3 }


pme1008AlmClientLossOfSyncPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Frame Alignment Loss :This 
        OID indicates the module is not 
        aligned with the incoming Client 
        signal <Help> Alarm indicating
         the module is not aligned with 
        the incoming client signal <Condtype> 
        CLIENT_LOSS_OF_SYNC <Probcause> 
        receiveFailure (41) <Alarmtype> 
        integrityViolation (7) <Polarity> 
        (2) 
        "
	::= { pme1008AlmclientHostLaneFaultEntry 2 }


--- *********************************************************
---     TABLE for the pme1008AlmlineNetworkLaneAlarmWarning1 articles
--- *********************************************************

pme1008AlmlineNetworkLaneAlarmWarning1Table OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008AlmlineNetworkLaneAlarmWarning1Entry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008AlmlineNetworkLaneAlarmWarning1 
        Article
        "
	::= { pme1008AlmLineUrg 104 }


pme1008AlmlineNetworkLaneAlarmWarning1Entry OBJECT-TYPE
	SYNTAX Pme1008AlmlineNetworkLaneAlarmWarning1Entry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008AlmlineNetworkLaneAlarmWarning1 
        table
        "
	INDEX   { pme1008AlmlineNetworkLaneAlarmWarning1Index }
	::= { pme1008AlmlineNetworkLaneAlarmWarning1Table 1 }


Pme1008AlmlineNetworkLaneAlarmWarning1Entry ::=
	SEQUENCE {
	pme1008AlmlineNetworkLaneAlarmWarning1Index
		INTEGER,
	pme1008AlmLineRxPwrHighAlaPortn
		EkiOnOff,
	pme1008AlmLineRxPwrLowAlaPortn
		EkiOnOff,
	pme1008AlmLineTempHighAlaPortn
		EkiOnOff,
	pme1008AlmLineTempLowAlaPortn
		EkiOnOff,
	pme1008AlmLineVccHighAlaPortn
		EkiOnOff,
	pme1008AlmLineVccLowAlaPortn
		EkiOnOff,
	pme1008AlmLineTxBiasHighAlaPortn
		EkiOnOff,
	pme1008AlmLineTxBiasLowAlaPortn
		EkiOnOff,
	pme1008AlmLineTxPwrHighAlaPortn
		EkiOnOff,
	pme1008AlmLineTxPwrLowAlaPortn
		EkiOnOff
	}


pme1008AlmlineNetworkLaneAlarmWarning1Index OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008AlmlineNetworkLaneAlarmWarning1 
        table
        "
	::= { pme1008AlmlineNetworkLaneAlarmWarning1Entry 1 }


pme1008AlmLineRxPwrHighAlaPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Trscv Rx Power High :This 
        OID indicates that the Trscv input 
        power of port is higher than the 
        threshold value written in the
         Trscv EEPROM <Help> Alarm indicating 
        that the Trscv input power of port 
        is higher than the threshold value 
        written in the Trscv EEPROM <Condtype> 
        LINE_RX_PWR_HIGH_ALA_1 <Probcause> 
        receiveFailure (41) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	::= { pme1008AlmlineNetworkLaneAlarmWarning1Entry 17 }


pme1008AlmLineRxPwrLowAlaPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Trscv Rx Power Low :This
         OID indicates that the Trscv input 
        power of port is lower than the 
        threshold value written in the
         Trscv EEPROM <Help> Alarm indicating 
        that the Trscv input power of port 
        is lower than the threshold value 
        written in the Trscv EEPROM <Condtype> 
        LINE_RX_PWR_LOW_ALA_1 <Probcause> 
        receiveFailure (41) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	::= { pme1008AlmlineNetworkLaneAlarmWarning1Entry 16 }


pme1008AlmLineTempHighAlaPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Trscv Temp High :This OID 
        indicates that the Trscv temperature 
        of port is higher than the threshold 
        value written in the Trscv EEPROM 
        <Help> Alarm indicating that the 
        Trscv temperature of port is higher 
        than the threshold value written 
        in the Trscv EEPROM <Condtype>
         LINE_TEMP_HIGH_ALA_1 <Probcause> 
        temperatureUnacceptable (51) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	::= { pme1008AlmlineNetworkLaneAlarmWarning1Entry 9 }


pme1008AlmLineTempLowAlaPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Trscv Temp Low :This OID
         indicates that the Trscv temperature 
        of port is lower than the threshold 
        value written in the Trscv EEPROM 
        <Help> Alarm indicating that the 
        Trscv temperature of port is lower 
        than the threshold value written 
        in the Trscv EEPROM <Condtype>
         LINE_TEMP_LOW_ALA_1 <Probcause> 
        temperatureUnacceptable (51) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	::= { pme1008AlmlineNetworkLaneAlarmWarning1Entry 8 }


pme1008AlmLineVccHighAlaPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Trscv Power Supply High :This 
        OID indicates that the Trscv power 
        supply of port is higher than the 
        threshold value written in the
         Trscv EEPROM <Help> Alarm indicating 
        that the Trscv power supply of
         port is higher than the threshold 
        value written in the Trscv EEPROM 
        <Condtype> LINE_VCC_HIGH_ALA_1
         <Probcause> powerProblem (36)
         <Alarmtype> equipmentAlarm (5) 
        <Polarity> (2) 
        "
	::= { pme1008AlmlineNetworkLaneAlarmWarning1Entry 7 }


pme1008AlmLineVccLowAlaPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Trscv Power Supply Low :This 
        OID indicates that the Trscv power 
        supply of port is lower than the 
        threshold value written in the
         Trscv EEPROM <Help> Alarm indicating 
        that the Trscv power supply of
         port is lower than the threshold 
        value written in the Trscv EEPROM 
        <Condtype> LINE_VCC_LOW_ALA_1 <Probcause> 
        powerProblem (36) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	::= { pme1008AlmlineNetworkLaneAlarmWarning1Entry 6 }


pme1008AlmLineTxBiasHighAlaPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Trscv Bias High :This OID 
        indicates that the Trscv laser
         bias current of port is higher 
        than the threshold value written 
        in the Trscv EEPROM <Help> Alarm 
        indicating that the Trscv laser 
        bias current of port is higher
         than the threshold value written 
        in the Trscv EEPROM <Condtype>
         LINE_TX_BIAS_HIGH_ALA_1 <Probcause> 
        transmitterFailure (56) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	::= { pme1008AlmlineNetworkLaneAlarmWarning1Entry 5 }


pme1008AlmLineTxBiasLowAlaPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Trscv Bias Low :This OID
         indicates that the Trscv laser 
        bias current of port is lower than 
        the threshold value written in
         the Trscv EEPROM <Help> Alarm
         indicating that the Trscv laser 
        bias current of port is lower than 
        the threshold value written in
         the Trscv EEPROM <Condtype> LINE_TX_BIAS_LOW_ALA_1 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	::= { pme1008AlmlineNetworkLaneAlarmWarning1Entry 4 }


pme1008AlmLineTxPwrHighAlaPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Trscv Tx Power High :This 
        OID indicates that the Trscv output 
        power of port is higher than the 
        threshold value written in the
         Trscv EEPROM <Help> Alarm indicating 
        that the Trscv output power of
         port is higher than the threshold 
        value written in the Trscv EEPROM 
        <Condtype> LINE_TX_PWR_HIGH_ALA_1 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	::= { pme1008AlmlineNetworkLaneAlarmWarning1Entry 3 }


pme1008AlmLineTxPwrLowAlaPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Trscv Tx Power Low :This
         OID indicates that the Trscv output 
        power of port is lower than the 
        threshold value written in the
         Trscv EEPROM <Help> Alarm indicating 
        that the Trscv output power of
         port is lower than the threshold 
        value written in the Trscv EEPROM 
        <Condtype> LINE_TX_PWR_LOW_ALA_1 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	::= { pme1008AlmlineNetworkLaneAlarmWarning1Entry 2 }


--- *********************************************************
---     TABLE for the pme1008AlmlineNetworkLaneAlarmWarning2 articles
--- *********************************************************

pme1008AlmlineNetworkLaneAlarmWarning2Table OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008AlmlineNetworkLaneAlarmWarning2Entry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008AlmlineNetworkLaneAlarmWarning2 
        Article
        "
	::= { pme1008AlmLineUrg 120 }


pme1008AlmlineNetworkLaneAlarmWarning2Entry OBJECT-TYPE
	SYNTAX Pme1008AlmlineNetworkLaneAlarmWarning2Entry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008AlmlineNetworkLaneAlarmWarning2 
        table
        "
	INDEX   { pme1008AlmlineNetworkLaneAlarmWarning2Index }
	::= { pme1008AlmlineNetworkLaneAlarmWarning2Table 1 }


Pme1008AlmlineNetworkLaneAlarmWarning2Entry ::=
	SEQUENCE {
	pme1008AlmlineNetworkLaneAlarmWarning2Index
		INTEGER,
	pme1008AlmLineRxPwrHighWngPortn
		EkiOnOff,
	pme1008AlmLineRxPwrLowWngPortn
		EkiOnOff,
	pme1008AlmLineTempHighWngPortn
		EkiOnOff,
	pme1008AlmLineTempLowWngPortn
		EkiOnOff,
	pme1008AlmLineVccHighWngPortn
		EkiOnOff,
	pme1008AlmLineVccLowWngPortn
		EkiOnOff,
	pme1008AlmLineTxBiasHighWngPortn
		EkiOnOff,
	pme1008AlmLineTxBiasLowWngPortn
		EkiOnOff,
	pme1008AlmLineTxPwrHighWngPortn
		EkiOnOff,
	pme1008AlmLineTxPwLowWngPortn
		EkiOnOff
	}


pme1008AlmlineNetworkLaneAlarmWarning2Index OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008AlmlineNetworkLaneAlarmWarning2 
        table
        "
	::= { pme1008AlmlineNetworkLaneAlarmWarning2Entry 1 }


pme1008AlmLineRxPwrHighWngPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Trscv Rx Power High Warning 
        :This OID indicates that the Trscv 
        input power is higher than the
         threshold value written in the 
        Trscv EEPROM <Help> Warning indicating 
        that the Trscv input power is higher 
        than the threshold value written 
        in the Trscv EEPROM <Condtype>
         LINE_RX_PWR_HIGH_WNG_1 <Probcause> 
        receiveFailure (41) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	::= { pme1008AlmlineNetworkLaneAlarmWarning2Entry 17 }


pme1008AlmLineRxPwrLowWngPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Trscv Rx Power Low Warning 
        :This OID indicates that the Trscv 
        input power is lower than the threshold 
        value written in the Trscv EEPROM 
        <Help> Warning indicating that
         the Trscv input power is lower 
        than the threshold value written 
        in the Trscv EEPROM <Condtype>
         LINE_RX_PWR_LOW_WNG_1 <Probcause> 
        receiveFailure (41) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	::= { pme1008AlmlineNetworkLaneAlarmWarning2Entry 16 }


pme1008AlmLineTempHighWngPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Trscv Temp High Warning :This 
        OID indicates that the Trscv temperature 
        is higher than the threshold value 
        written in the Trscv EEPROM <Help> 
        Warning indicating that the Trscv 
        temperature is higher than the
         threshold value written in the 
        Trscv EEPROM <Condtype> LINE_TEMP_HIGH_WNG_1 
        <Probcause> temperatureUnacceptable 
        (51) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	::= { pme1008AlmlineNetworkLaneAlarmWarning2Entry 9 }


pme1008AlmLineTempLowWngPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Trscv Temp Low Warning :This 
        OID indicates that the Trscv temperature 
        is lower than the threshold value 
        written in the Trscv EEPROM <Help> 
        Warning indicating that the Trscv 
        temperature is lower than the threshold 
        value written in the Trscv EEPROM 
        <Condtype> LINE_TEMP_LOW_WNG_1
         <Probcause> temperatureUnacceptable 
        (51) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	::= { pme1008AlmlineNetworkLaneAlarmWarning2Entry 8 }


pme1008AlmLineVccHighWngPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Trscv Power Supply High Warning 
        :This OID indicates that the Trscv 
        power supply is higher than the 
        threshold value written in the
         Trscv EEPROM <Help> Warning indicating 
        that the Trscv power supply is
         higher than the threshold value 
        written in the Trscv EEPROM <Condtype> 
        LINE_VCC_HIGH_WNG_1 <Probcause> 
        powerProblem (36) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	::= { pme1008AlmlineNetworkLaneAlarmWarning2Entry 7 }


pme1008AlmLineVccLowWngPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Trscv Power Supply Low Warning 
        :This OID indicates that the Trscv 
        power supply is lower than the
         threshold value written in the 
        Trscv EEPROM <Help> Warning indicating 
        that the Trscv power supply is
         lower than the threshold value 
        written in the Trscv EEPROM <Condtype> 
        LINE_VCC_LOW_WNG_1 <Probcause>
         powerProblem (36) <Alarmtype>
         equipmentAlarm (5) <Polarity>
         (2) 
        "
	::= { pme1008AlmlineNetworkLaneAlarmWarning2Entry 6 }


pme1008AlmLineTxBiasHighWngPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Trscv Bias High Warning :This 
        OID indicates that the Trscv laser 
        bias current is higher than the 
        threshold value written in the
         Trscv EEPROM <Help> Warning indicating 
        that the Trscv laser bias current 
        is higher than the threshold value 
        written in the Trscv EEPROM <Condtype> 
        LINE_TX_BIAS_HIGH_WNG_1 <Probcause> 
        transmitterFailure (56) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	::= { pme1008AlmlineNetworkLaneAlarmWarning2Entry 5 }


pme1008AlmLineTxBiasLowWngPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Trscv Bias Low Warning :This 
        OID indicates that the Trscv laser 
        bias current is lower than the
         threshold value written in the 
        Trscv EEPROM <Help> Warning indicating 
        that the Trscv laser bias current 
        is lower than the threshold value 
        written in the Trscv EEPROM <Condtype> 
        LINE_TX_BIAS_LOW_WNG_1 <Probcause> 
        transmitterFailure (56) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	::= { pme1008AlmlineNetworkLaneAlarmWarning2Entry 4 }


pme1008AlmLineTxPwrHighWngPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Trscv Tx Power High Warning 
        :This OID indicates that the Trscv 
        output power is higher than the 
        threshold value written in the
         Trscv EEPROM <Help> Warning indicating 
        that the Trscv output power is
         higher than the threshold value 
        written in the Trscv EEPROM <Condtype> 
        LINE_TX_PWR_HIGH_WNG_1 <Probcause> 
        transmitterFailure (56) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	::= { pme1008AlmlineNetworkLaneAlarmWarning2Entry 3 }


pme1008AlmLineTxPwLowWngPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Trscv Tx Power Low Warning 
        :This OID indicates that the Trscv 
        output power is lower than the
         threshold value written in the 
        Trscv EEPROM <Help> Warning indicating 
        that the Trscv output power is
         lower than the threshold value 
        written in the Trscv EEPROM <Condtype> 
        LINE_TX_PW_LOW_WNG_1 <Probcause> 
        transmitterFailure (56) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	::= { pme1008AlmlineNetworkLaneAlarmWarning2Entry 2 }


--- *********************************************************
---     TABLE for the pme1008AlmlineHostLaneFault articles
--- *********************************************************

pme1008AlmlineHostLaneFaultTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008AlmlineHostLaneFaultEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008AlmlineHostLaneFault 
        Article
        "
	::= { pme1008AlmLineUrg 152 }


pme1008AlmlineHostLaneFaultEntry OBJECT-TYPE
	SYNTAX Pme1008AlmlineHostLaneFaultEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008AlmlineHostLaneFault 
        table
        "
	INDEX   { pme1008AlmlineHostLaneFaultIndex }
	::= { pme1008AlmlineHostLaneFaultTable 1 }


Pme1008AlmlineHostLaneFaultEntry ::=
	SEQUENCE {
	pme1008AlmlineHostLaneFaultIndex
		INTEGER,
	pme1008AlmLineLossOfFramePortn
		EkiOnOff,
	pme1008AlmLineInputLossOfSignalPortn
		EkiOnOff
	}


pme1008AlmlineHostLaneFaultIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008AlmlineHostLaneFault 
        table
        "
	::= { pme1008AlmlineHostLaneFaultEntry 1 }


pme1008AlmLineLossOfFramePortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Loss Of Frame :This OID indicates 
        the module is not aligned with
         the incoming Line signal<Help> 
         This alarm indicates if a Loss 
        Of Frame has been detected on the 
        line port <Condtype> LINE_LOSS_OF_FRAME 
        <Probcause> receiveFailure (41) 
        <Alarmtype> integrityViolation
         (7) <Polarity> (2) 
        "
	::= { pme1008AlmlineHostLaneFaultEntry 3 }


pme1008AlmLineInputLossOfSignalPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Input Loss Of Signal :This 
        OID indicates a Loss of Signal
         is detected on the Line Trscv<Help> 
         This alarm indicates if an Optical 
        Path Break has been detected on 
        the line port <Condtype> LINE_INPUT_LOSS_OF_SIGNAL 
        <Probcause> receiveFailure (41) 
        <Alarmtype> physicalViolation (9) 
        <Polarity> (2) 
        "
	::= { pme1008AlmlineHostLaneFaultEntry 2 }


--- *********************************************************
---     TABLE for the pme1008AlmclientSfpAlmDdm articles
--- *********************************************************

pme1008AlmclientSfpAlmDdmTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008AlmclientSfpAlmDdmEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008AlmclientSfpAlmDdm 
        Article
        "
	::= { pme1008AlmClientUrg 216 }


pme1008AlmclientSfpAlmDdmEntry OBJECT-TYPE
	SYNTAX Pme1008AlmclientSfpAlmDdmEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008AlmclientSfpAlmDdm 
        table
        "
	INDEX   { pme1008AlmclientSfpAlmDdmIndex }
	::= { pme1008AlmclientSfpAlmDdmTable 1 }


Pme1008AlmclientSfpAlmDdmEntry ::=
	SEQUENCE {
	pme1008AlmclientSfpAlmDdmIndex
		INTEGER,
	pme1008AlmClientRxPwrHighAlaPortn
		EkiOnOff,
	pme1008AlmClientRxPwrLowAlaPortn
		EkiOnOff,
	pme1008AlmClientTempHighAlaPortn
		EkiOnOff,
	pme1008AlmClientTempLowAlaPortn
		EkiOnOff,
	pme1008AlmClientVccHighAlaPortn
		EkiOnOff,
	pme1008AlmClientVccLowAlaPortn
		EkiOnOff,
	pme1008AlmClientTxBiasHighAlaPortn
		EkiOnOff,
	pme1008AlmClientTxBiasLowAlaPortn
		EkiOnOff,
	pme1008AlmClientTxPwrHighAlaPortn
		EkiOnOff,
	pme1008AlmClientTxPwrLowAlaPortn
		EkiOnOff
	}


pme1008AlmclientSfpAlmDdmIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008AlmclientSfpAlmDdm 
        table
        "
	::= { pme1008AlmclientSfpAlmDdmEntry 1 }


pme1008AlmClientRxPwrHighAlaPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Trscv Rx Power High :This 
        OID indicates that the Trscv input 
        power of port is higher than the 
        threshold value written in the
         Trscv EEPROM <Help> Alarm indicating 
        that the Trscv input power of port 
        is higher than the threshold value 
        written in the Trscv EEPROM <Condtype> 
        CLIENT_RX_PWR_HIGH_ALA_1 <Probcause> 
        receiveFailure (41) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	::= { pme1008AlmclientSfpAlmDdmEntry 17 }


pme1008AlmClientRxPwrLowAlaPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Trscv Rx Power Low :This 
        OID indicates that the Trscv input 
        power of port is lower than the 
        threshold value written in the
         Trscv EEPROM <Help> Alarm indicating 
        that the Trscv input power of port 
        is lower than the threshold value 
        written in the Trscv EEPROM <Condtype> 
        CLIENT_RX_PWR_LOW_ALA_1 <Probcause> 
        receiveFailure (41) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	::= { pme1008AlmclientSfpAlmDdmEntry 16 }


pme1008AlmClientTempHighAlaPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Trscv Temp High :This OID 
        indicates that the Trscv temperature 
        of port is higher than the threshold 
        value written in the Trscv EEPROM 
        <Help> Alarm indicating that the 
        Trscv temperature of port is higher 
        than the threshold value written 
        in the Trscv EEPROM <Condtype>
         CLIENT_TEMP_HIGH_ALA_1 <Probcause> 
        temperatureUnacceptable (51) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	::= { pme1008AlmclientSfpAlmDdmEntry 9 }


pme1008AlmClientTempLowAlaPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Trscv Temp Low :This OID 
        indicates that the Trscv temperature 
        of port is lower than the threshold 
        value written in the Trscv EEPROM 
        <Help> Alarm indicating that the 
        Trscv temperature of port is lower 
        than the threshold value written 
        in the Trscv EEPROM <Condtype>
         CLIENT_TEMP_LOW_ALA_1 <Probcause> 
        temperatureUnacceptable (51) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	::= { pme1008AlmclientSfpAlmDdmEntry 8 }


pme1008AlmClientVccHighAlaPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Trscv Power Supply High 
        :This OID indicates that the Trscv 
        power supply of port is higher
         than the threshold value written 
        in the Trscv EEPROM <Help> Alarm 
        indicating that the Trscv power 
        supply of port is higher than the 
        threshold value written in the
         Trscv EEPROM <Condtype> CLIENT_VCC_HIGH_ALA_1 
        <Probcause> powerProblem (36) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	::= { pme1008AlmclientSfpAlmDdmEntry 7 }


pme1008AlmClientVccLowAlaPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Trscv Power Supply Low
         :This OID indicates that the Trscv 
        power supply of port is lower than 
        the threshold value written in
         the Trscv EEPROM <Help> Alarm
         indicating that the Trscv power 
        supply of port is lower than the 
        threshold value written in the
         Trscv EEPROM <Condtype> CLIENT_VCC_LOW_ALA_1 
        <Probcause> powerProblem (36) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	::= { pme1008AlmclientSfpAlmDdmEntry 6 }


pme1008AlmClientTxBiasHighAlaPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Trscv Bias High :This OID 
        indicates that the Trscv laser
         bias current of port is higher 
        than the threshold value written 
        in the Trscv EEPROM <Help> Alarm 
        indicating that the Trscv laser 
        bias current of port is higher
         than the threshold value written 
        in the Trscv EEPROM <Condtype>
         CLIENT_TX_BIAS_HIGH_ALA_1 <Probcause> 
        transmitterFailure (56) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	::= { pme1008AlmclientSfpAlmDdmEntry 5 }


pme1008AlmClientTxBiasLowAlaPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Trscv Bias Low :This OID 
        indicates that the Trscv laser
         bias current of port is lower
         than the threshold value written 
        in the Trscv EEPROM <Help> Alarm 
        indicating that the Trscv laser 
        bias current of port is lower than 
        the threshold value written in
         the Trscv EEPROM <Condtype> CLIENT_TX_BIAS_LOW_ALA_1 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	::= { pme1008AlmclientSfpAlmDdmEntry 4 }


pme1008AlmClientTxPwrHighAlaPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Trscv Tx Power High :This 
        OID indicates that the Trscv output 
        power of port is higher than the 
        threshold value written in the
         Trscv EEPROM <Help> Alarm indicating 
        that the Trscv output power of
         port is higher than the threshold 
        value written in the Trscv EEPROM 
        <Condtype> CLIENT_TX_PWR_HIGH_ALA_1 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	::= { pme1008AlmclientSfpAlmDdmEntry 3 }


pme1008AlmClientTxPwrLowAlaPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Trscv Tx Power Low :This 
        OID indicates that the Trscv output 
        power of port is lower than the 
        threshold value written in the
         Trscv EEPROM <Help> Alarm indicating 
        that the Trscv output power of
         port is lower than the threshold 
        value written in the Trscv EEPROM 
        <Condtype> CLIENT_TX_PWR_LOW_ALA_1 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	::= { pme1008AlmclientSfpAlmDdmEntry 2 }


--- *********************************************************
---     TABLE for the pme1008AlmclientSfpWarnDdm articles
--- *********************************************************

pme1008AlmclientSfpWarnDdmTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008AlmclientSfpWarnDdmEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008AlmclientSfpWarnDdm 
        Article
        "
	::= { pme1008AlmClientNurg 232 }


pme1008AlmclientSfpWarnDdmEntry OBJECT-TYPE
	SYNTAX Pme1008AlmclientSfpWarnDdmEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008AlmclientSfpWarnDdm 
        table
        "
	INDEX   { pme1008AlmclientSfpWarnDdmIndex }
	::= { pme1008AlmclientSfpWarnDdmTable 1 }


Pme1008AlmclientSfpWarnDdmEntry ::=
	SEQUENCE {
	pme1008AlmclientSfpWarnDdmIndex
		INTEGER,
	pme1008AlmClientRxPwrHighWngPortn
		EkiOnOff,
	pme1008AlmClientRxPwrLowWngPortn
		EkiOnOff,
	pme1008AlmClientTempHighWngPortn
		EkiOnOff,
	pme1008AlmClientTempLowWngPortn
		EkiOnOff,
	pme1008AlmClientVccHighWngPortn
		EkiOnOff,
	pme1008AlmClientVccLowWngPortn
		EkiOnOff,
	pme1008AlmClientTxBiasHighWngPortn
		EkiOnOff,
	pme1008AlmClientTxBiasLowWngPortn
		EkiOnOff,
	pme1008AlmClientTxPwrHighWngPortn
		EkiOnOff,
	pme1008AlmClientTxPwLowWngPortn
		EkiOnOff
	}


pme1008AlmclientSfpWarnDdmIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008AlmclientSfpWarnDdm 
        table
        "
	::= { pme1008AlmclientSfpWarnDdmEntry 1 }


pme1008AlmClientRxPwrHighWngPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Trscv Rx Power High Warning 
        :This OID indicates that the Trscv 
        input power is higher than the
         threshold value written in the 
        Trscv EEPROM <Help> Warning indicating 
        that the Trscv input power is higher 
        than the threshold value written 
        in the Trscv EEPROM <Condtype>
         CLIENT_RX_PWR_HIGH_WNG_1 <Probcause> 
        receiveFailure (41) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	::= { pme1008AlmclientSfpWarnDdmEntry 17 }


pme1008AlmClientRxPwrLowWngPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Trscv Rx Power Low Warning 
        :This OID indicates that the Trscv 
        input power is lower than the threshold 
        value written in the Trscv EEPROM 
        <Help> Warning indicating that
         the Trscv input power is lower 
        than the threshold value written 
        in the Trscv EEPROM <Condtype>
         CLIENT_RX_PWR_LOW_WNG_1 <Probcause> 
        receiveFailure (41) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	::= { pme1008AlmclientSfpWarnDdmEntry 16 }


pme1008AlmClientTempHighWngPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Trscv Temp High Warning 
        :This OID indicates that the Trscv 
        temperature is higher than the
         threshold value written in the 
        Trscv EEPROM <Help> Warning indicating 
        that the Trscv temperature is higher 
        than the threshold value written 
        in the Trscv EEPROM <Condtype>
         CLIENT_TEMP_HIGH_WNG_1 <Probcause> 
        temperatureUnacceptable (51) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	::= { pme1008AlmclientSfpWarnDdmEntry 9 }


pme1008AlmClientTempLowWngPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Trscv Temp Low Warning
         :This OID indicates that the Trscv 
        temperature is lower than the threshold 
        value written in the Trscv EEPROM 
        <Help> Warning indicating that
         the Trscv temperature is lower 
        than the threshold value written 
        in the Trscv EEPROM <Condtype>
         CLIENT_TEMP_LOW_WNG_1 <Probcause> 
        temperatureUnacceptable (51) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	::= { pme1008AlmclientSfpWarnDdmEntry 8 }


pme1008AlmClientVccHighWngPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Trscv Power Supply High 
        Warning :This OID indicates that 
        the Trscv power supply is higher 
        than the threshold value written 
        in the Trscv EEPROM <Help> Warning 
        indicating that the Trscv power 
        supply is higher than the threshold 
        value written in the Trscv EEPROM 
        <Condtype> CLIENT_VCC_HIGH_WNG_1 
        <Probcause> powerProblem (36) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	::= { pme1008AlmclientSfpWarnDdmEntry 7 }


pme1008AlmClientVccLowWngPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Trscv Power Supply Low
         Warning :This OID indicates that 
        the Trscv power supply is lower 
        than the threshold value written 
        in the Trscv EEPROM <Help> Warning 
        indicating that the Trscv power 
        supply is lower than the threshold 
        value written in the Trscv EEPROM 
        <Condtype> CLIENT_VCC_LOW_WNG_1 
        <Probcause> powerProblem (36) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	::= { pme1008AlmclientSfpWarnDdmEntry 6 }


pme1008AlmClientTxBiasHighWngPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Trscv Bias High Warning 
        :This OID indicates that the Trscv 
        laser bias current is higher than 
        the threshold value written in
         the Trscv EEPROM <Help> Warning 
        indicating that the Trscv laser 
        bias current is higher than the 
        threshold value written in the
         Trscv EEPROM <Condtype> CLIENT_TX_BIAS_HIGH_WNG_1 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	::= { pme1008AlmclientSfpWarnDdmEntry 5 }


pme1008AlmClientTxBiasLowWngPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Trscv Bias Low Warning
         :This OID indicates that the Trscv 
        laser bias current is lower than 
        the threshold value written in
         the Trscv EEPROM <Help> Warning 
        indicating that the Trscv laser 
        bias current is lower than the
         threshold value written in the 
        Trscv EEPROM <Condtype> CLIENT_TX_BIAS_LOW_WNG_1 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	::= { pme1008AlmclientSfpWarnDdmEntry 4 }


pme1008AlmClientTxPwrHighWngPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Trscv Tx Power High Warning 
        :This OID indicates that the Trscv 
        output power is higher than the 
        threshold value written in the
         Trscv EEPROM <Help> Warning indicating 
        that the Trscv output power is
         higher than the threshold value 
        written in the Trscv EEPROM <Condtype> 
        CLIENT_TX_PWR_HIGH_WNG_1 <Probcause> 
        transmitterFailure (56) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	::= { pme1008AlmclientSfpWarnDdmEntry 3 }


pme1008AlmClientTxPwLowWngPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Trscv Tx Power Low Warning 
        :This OID indicates that the Trscv 
        output power is lower than the
         threshold value written in the 
        Trscv EEPROM <Help> Warning indicating 
        that the Trscv output power is
         lower than the threshold value 
        written in the Trscv EEPROM <Condtype> 
        CLIENT_TX_PW_LOW_WNG_1 <Probcause> 
        transmitterFailure (56) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	::= { pme1008AlmclientSfpWarnDdmEntry 2 }







--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     CONTROLS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the confMgnt1 article
--- *****************************************************
pme1008CtrlconfMgnt1 OBJECT IDENTIFIER ::= { pme1008CtrlOther 1 }




pme1008CtrlConf2Clear1 OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Clear Configuration Tables :This 
        OID clears the configuration tables 
        from configuration2 in the flash. 
         <Help>  This control restores
         the default configuration of the 
        module
        "
	  ::= { pme1008CtrlconfMgnt1 14 }



pme1008CtrlConf2Flash1 OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Write Configuration Tables :This 
        OID saves the current configuration 
        of the PM as configuration2 in
         the flash.  <Help>  This control 
        saves the customer configuration 
        on the module
        "
	  ::= { pme1008CtrlconfMgnt1 10 }



pme1008CtrlConf2Load1 OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Load Configuration Tables Set
         Nb 2 :When set this OID enables 
        loading from flash configuration2 
        into the PM.
        "
	  ::= { pme1008CtrlconfMgnt1 2 }



pme1008CtrlConf1Load1 OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Load Configuration Tables Set
         Nb 1 :When set this OID enables 
        loading from flash configuration1 
        into the PM.
        "
	  ::= { pme1008CtrlconfMgnt1 1 }



--- *****************************************************
---     LEAF for the synth4 article
--- *****************************************************
pme1008Ctrlsynth4 OBJECT IDENTIFIER ::= { pme1008CtrlOther 4 }




pme1008CtrlCorrelatOff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Disable Alarm Correlation :This 
        OID disables the alarm correlation 
        in the PM.
        "
	  ::= { pme1008Ctrlsynth4 2 }



pme1008CtrlCorrelatOn OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Enable Alarm Correlation :This 
        OID enables the alarm correlation 
        in the PM.
        "
	  ::= { pme1008Ctrlsynth4 1 }



--- *****************************************************
---     LEAF for the swMgnt article
--- *****************************************************
pme1008CtrlswMgnt OBJECT IDENTIFIER ::= { pme1008CtrlOther 5 }




pme1008CtrlLoadSwBank2 OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Set Software Nb 2 As Active :This 
        OID, when set, loads the SW from 
        bank2 into the PM. It must be followed 
        by a reset.  <Help>  This controls 
        selects the second SW bank as the 
        active bank for the next module 
        reset
        "
	  ::= { pme1008CtrlswMgnt 6 }



pme1008CtrlLoadSwBank1 OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Set Software Nb 1 As Active :This 
        OID, when set, loads the SW from 
        bank1 into the PM. It must be followed 
        by a reset.  <Help>  This controls 
        selects the first SW bank as the 
        active bank for the next module 
        reset
        "
	  ::= { pme1008CtrlswMgnt 5 }



pme1008CtrlWarmReset OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        PM Warm Reset :This OID, when
         set, causes a warm reset of the 
        PM. This reset is not traffic affecting, 
        and the configuration of PM remains 
        unchanged.  <Help>  This control 
        initiates a warm reset of the module. 
        "
	  ::= { pme1008CtrlswMgnt 3 }



pme1008CtrlColdReset OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        PM Cold Reset :This OID, when
         set, causes a cold reset of the 
        PM. This reset is traffic affecting, 
        and the configuration of PM is
         reloaded on start-up.  <Help>
          This control initiates a cold 
        reset of the module. 
        "
	  ::= { pme1008CtrlswMgnt 2 }



--- *****************************************************
---     LEAF for the gwMgnt article
--- *****************************************************
pme1008CtrlgwMgnt OBJECT IDENTIFIER ::= { pme1008CtrlOther 6 }




pme1008CtrlLoadGwBank4 OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Set Gateware Nb 4 As Active :This 
        OID, when set, loads the GW from 
        bank4 (Flash) into the PM. It is 
        followed by an automatic gateware 
        cold reset.
        "
	  ::= { pme1008CtrlgwMgnt 8 }



pme1008CtrlLoadGwBank3 OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Set Gateware Nb 3 As Active :This 
        OID, when set, loads the GW from 
        bank3 (Flash) into the PM. It is 
        followed by an automatic gateware 
        cold reset.  <Help>  This controls 
        initiates a cold reset of the module 
        and select the third GW bank as 
        the active bank
        "
	  ::= { pme1008CtrlgwMgnt 7 }



pme1008CtrlLoadGwBank2 OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Set Gateware Nb 2 As Active :This 
        OID, when set, loads the GW from 
        bank2 (Flash) into the PM. It is 
        followed by an automatic gateware 
        cold reset.
        "
	  ::= { pme1008CtrlgwMgnt 6 }



pme1008CtrlLoadGwBank1 OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Set Gateware Nb 1 As Active :This 
        OID, when set, loads the GW from 
        bank1 (Flash) into the PM. It is 
        followed by an automatic gateware 
        cold reset.  <Help>  This controls 
        initiates a cold reset of the module 
        and select the first GW bank as 
        the active bank
        "
	  ::= { pme1008CtrlgwMgnt 5 }



pme1008CtrlCurrentGwReset OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Active Gateware Reset :This OID, 
        when set, resets the active gateware. 
        It is traffic affecting.
        "
	  ::= { pme1008CtrlgwMgnt 1 }



--- *********************************************************
---     TABLE for the pme1008CtrlaccessLoop articles
--- *********************************************************

pme1008CtrlaccessLoopTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CtrlaccessLoopEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008CtrlaccessLoop
         Article
        "
	::= { pme1008CtrlClient 16 }


pme1008CtrlaccessLoopEntry OBJECT-TYPE
	SYNTAX Pme1008CtrlaccessLoopEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008CtrlaccessLoop 
        table
        "
	INDEX   { pme1008CtrlaccessLoopIndex }
	::= { pme1008CtrlaccessLoopTable 1 }


Pme1008CtrlaccessLoopEntry ::=
	SEQUENCE {
	pme1008CtrlaccessLoopIndex
		INTEGER,
	pme1008CtrlaccessLoopPortn
		EkiState
	}


pme1008CtrlaccessLoopIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008CtrlaccessLoop 
        table
        "
	::= { pme1008CtrlaccessLoopEntry 1 }


pme1008CtrlaccessLoopPortn OBJECT-TYPE
	SYNTAX  EkiState
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Client Facility Loopback :This 
        OID, when set at '1' puts the client 
        port in loopback, looping the received 
        10 Gb/s signal on the transmit
         10 Gb/s output.  <Help> This control 
        enables the Out Loopback on the 
        client port, looping the client 
        input signal on the client output
        "
	::= { pme1008CtrlaccessLoopEntry 2 }


--- *********************************************************
---     TABLE for the pme1008CtrlclientLoopToLine articles
--- *********************************************************

pme1008CtrlclientLoopToLineTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CtrlclientLoopToLineEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008CtrlclientLoopToLine 
        Article
        "
	::= { pme1008CtrlClient 17 }


pme1008CtrlclientLoopToLineEntry OBJECT-TYPE
	SYNTAX Pme1008CtrlclientLoopToLineEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008CtrlclientLoopToLine 
        table
        "
	INDEX   { pme1008CtrlclientLoopToLineIndex }
	::= { pme1008CtrlclientLoopToLineTable 1 }


Pme1008CtrlclientLoopToLineEntry ::=
	SEQUENCE {
	pme1008CtrlclientLoopToLineIndex
		INTEGER,
	pme1008CtrlclientLoopToLinePortn
		EkiState
	}


pme1008CtrlclientLoopToLineIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008CtrlclientLoopToLine 
        table
        "
	::= { pme1008CtrlclientLoopToLineEntry 1 }


pme1008CtrlclientLoopToLinePortn OBJECT-TYPE
	SYNTAX  EkiState
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Client Terminal Loopback :This 
        OID, when set, puts the client
         port in loop back, looping the 
        10 Gb/s output signal on the 10 
        Gb/s input.<Help> This control
         enables the In Loopback on the 
        client port, looping the client 
        output signal on the client input
        "
	::= { pme1008CtrlclientLoopToLineEntry 2 }


--- *********************************************************
---     TABLE for the pme1008CtrlcsfUpIns articles
--- *********************************************************

pme1008CtrlcsfUpInsTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CtrlcsfUpInsEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008CtrlcsfUpIns Article
        "
	::= { pme1008CtrlClient 21 }


pme1008CtrlcsfUpInsEntry OBJECT-TYPE
	SYNTAX Pme1008CtrlcsfUpInsEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008CtrlcsfUpIns 
        table
        "
	INDEX   { pme1008CtrlcsfUpInsIndex }
	::= { pme1008CtrlcsfUpInsTable 1 }


Pme1008CtrlcsfUpInsEntry ::=
	SEQUENCE {
	pme1008CtrlcsfUpInsIndex
		INTEGER,
	pme1008CtrlcsfUpInsPortn
		EkiState
	}


pme1008CtrlcsfUpInsIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008CtrlcsfUpIns 
        table
        "
	::= { pme1008CtrlcsfUpInsEntry 1 }


pme1008CtrlcsfUpInsPortn OBJECT-TYPE
	SYNTAX  EkiState
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Client Signal Fail Insertion :This 
        OID, when set, inserts  a client 
        signal fail in the upstream client 
        Port.  <Help>  This control inserts 
        a Client Signal Fail for the client 
        port
        "
	::= { pme1008CtrlcsfUpInsEntry 2 }


--- *********************************************************
---     TABLE for the pme1008CtrlcaisDwIns articles
--- *********************************************************

pme1008CtrlcaisDwInsTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CtrlcaisDwInsEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008CtrlcaisDwIns Article
        "
	::= { pme1008CtrlClient 22 }


pme1008CtrlcaisDwInsEntry OBJECT-TYPE
	SYNTAX Pme1008CtrlcaisDwInsEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008CtrlcaisDwIns 
        table
        "
	INDEX   { pme1008CtrlcaisDwInsIndex }
	::= { pme1008CtrlcaisDwInsTable 1 }


Pme1008CtrlcaisDwInsEntry ::=
	SEQUENCE {
	pme1008CtrlcaisDwInsIndex
		INTEGER,
	pme1008CtrlcaisDwInsPortn
		EkiState
	}


pme1008CtrlcaisDwInsIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008CtrlcaisDwIns 
        table
        "
	::= { pme1008CtrlcaisDwInsEntry 1 }


pme1008CtrlcaisDwInsPortn OBJECT-TYPE
	SYNTAX  EkiState
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Client AIS Insertion :This OID, 
        when set, inserts a client AIS
         on the downstream client Port. 
         <Help>  This control inserts a 
        Client AIS for the client port
        "
	::= { pme1008CtrlcaisDwInsEntry 2 }


--- *********************************************************
---     TABLE for the pme1008CtrlclientOci articles
--- *********************************************************

pme1008CtrlclientOciTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CtrlclientOciEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008CtrlclientOci Article
        "
	::= { pme1008CtrlClient 23 }


pme1008CtrlclientOciEntry OBJECT-TYPE
	SYNTAX Pme1008CtrlclientOciEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008CtrlclientOci 
        table
        "
	INDEX   { pme1008CtrlclientOciIndex }
	::= { pme1008CtrlclientOciTable 1 }


Pme1008CtrlclientOciEntry ::=
	SEQUENCE {
	pme1008CtrlclientOciIndex
		INTEGER,
	pme1008CtrlclientOciPortn
		EkiState
	}


pme1008CtrlclientOciIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008CtrlclientOci 
        table
        "
	::= { pme1008CtrlclientOciEntry 1 }


pme1008CtrlclientOciPortn OBJECT-TYPE
	SYNTAX  EkiState
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        ODU2e-OCI :Label  <Help>  This 
        control inserts a Client OCI
        "
	::= { pme1008CtrlclientOciEntry 2 }


--- *********************************************************
---     TABLE for the pme1008CtrlclientLck articles
--- *********************************************************

pme1008CtrlclientLckTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CtrlclientLckEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008CtrlclientLck Article
        "
	::= { pme1008CtrlClient 24 }


pme1008CtrlclientLckEntry OBJECT-TYPE
	SYNTAX Pme1008CtrlclientLckEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008CtrlclientLck 
        table
        "
	INDEX   { pme1008CtrlclientLckIndex }
	::= { pme1008CtrlclientLckTable 1 }


Pme1008CtrlclientLckEntry ::=
	SEQUENCE {
	pme1008CtrlclientLckIndex
		INTEGER,
	pme1008CtrlclientLckPortn
		EkiState
	}


pme1008CtrlclientLckIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008CtrlclientLck 
        table
        "
	::= { pme1008CtrlclientLckEntry 1 }


pme1008CtrlclientLckPortn OBJECT-TYPE
	SYNTAX  EkiState
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        ODU2e-LCK :Label  <Help>  This 
        control inserts a Client LCK
        "
	::= { pme1008CtrlclientLckEntry 2 }


--- *********************************************************
---     TABLE for the pme1008CtrlclientAis articles
--- *********************************************************

pme1008CtrlclientAisTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CtrlclientAisEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008CtrlclientAis Article
        "
	::= { pme1008CtrlClient 25 }


pme1008CtrlclientAisEntry OBJECT-TYPE
	SYNTAX Pme1008CtrlclientAisEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008CtrlclientAis 
        table
        "
	INDEX   { pme1008CtrlclientAisIndex }
	::= { pme1008CtrlclientAisTable 1 }


Pme1008CtrlclientAisEntry ::=
	SEQUENCE {
	pme1008CtrlclientAisIndex
		INTEGER,
	pme1008CtrlclientAisPortn
		EkiState
	}


pme1008CtrlclientAisIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008CtrlclientAis 
        table
        "
	::= { pme1008CtrlclientAisEntry 1 }


pme1008CtrlclientAisPortn OBJECT-TYPE
	SYNTAX  EkiState
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        ODU2e-AIS :Label  <Help>  This 
        control inserts a Client AIS 
        "
	::= { pme1008CtrlclientAisEntry 2 }


--- *********************************************************
---     TABLE for the pme1008CtrlclientBdi articles
--- *********************************************************

pme1008CtrlclientBdiTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CtrlclientBdiEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008CtrlclientBdi Article
        "
	::= { pme1008CtrlClient 26 }


pme1008CtrlclientBdiEntry OBJECT-TYPE
	SYNTAX Pme1008CtrlclientBdiEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008CtrlclientBdi 
        table
        "
	INDEX   { pme1008CtrlclientBdiIndex }
	::= { pme1008CtrlclientBdiTable 1 }


Pme1008CtrlclientBdiEntry ::=
	SEQUENCE {
	pme1008CtrlclientBdiIndex
		INTEGER,
	pme1008CtrlclientBdiPortn
		EkiState
	}


pme1008CtrlclientBdiIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008CtrlclientBdi 
        table
        "
	::= { pme1008CtrlclientBdiEntry 1 }


pme1008CtrlclientBdiPortn OBJECT-TYPE
	SYNTAX  EkiState
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        ODU2e-BDI :Label  <Help>  This 
        control inserts a Client BDI
        "
	::= { pme1008CtrlclientBdiEntry 2 }


--- *********************************************************
---     TABLE for the pme1008CtrlcommAccessLoop articles
--- *********************************************************

pme1008CtrlcommAccessLoopTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CtrlcommAccessLoopEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008CtrlcommAccessLoop 
        Article
        "
	::= { pme1008CtrlLine 64 }


pme1008CtrlcommAccessLoopEntry OBJECT-TYPE
	SYNTAX Pme1008CtrlcommAccessLoopEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008CtrlcommAccessLoop 
        table
        "
	INDEX   { pme1008CtrlcommAccessLoopIndex }
	::= { pme1008CtrlcommAccessLoopTable 1 }


Pme1008CtrlcommAccessLoopEntry ::=
	SEQUENCE {
	pme1008CtrlcommAccessLoopIndex
		INTEGER,
	pme1008CtrlcommAccessLoopPortn
		EkiState
	}


pme1008CtrlcommAccessLoopIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008CtrlcommAccessLoop 
        table
        "
	::= { pme1008CtrlcommAccessLoopEntry 1 }


pme1008CtrlcommAccessLoopPortn OBJECT-TYPE
	SYNTAX  EkiState
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Line Terminal Loopback :This OID, 
        when set, puts the module in common 
        access loop back, looping the 10 
        Gb/s output signal on the 10 Gb/s 
        input.<Help> This control enables 
        the In Loopback on the line port, 
        looping the 100 Gb/s output signal 
        on the 100 Gb/s input
        "
	::= { pme1008CtrlcommAccessLoopEntry 2 }


--- *********************************************************
---     TABLE for the pme1008CtrllineLoop articles
--- *********************************************************

pme1008CtrllineLoopTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CtrllineLoopEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008CtrllineLoop Article
        "
	::= { pme1008CtrlLine 66 }


pme1008CtrllineLoopEntry OBJECT-TYPE
	SYNTAX Pme1008CtrllineLoopEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008CtrllineLoop 
        table
        "
	INDEX   { pme1008CtrllineLoopIndex }
	::= { pme1008CtrllineLoopTable 1 }


Pme1008CtrllineLoopEntry ::=
	SEQUENCE {
	pme1008CtrllineLoopIndex
		INTEGER,
	pme1008CtrllineLoopPortn
		EkiState
	}


pme1008CtrllineLoopIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008CtrllineLoop 
        table
        "
	::= { pme1008CtrllineLoopEntry 1 }


pme1008CtrllineLoopPortn OBJECT-TYPE
	SYNTAX  EkiState
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Line Facility Loopback :This OID, 
        when set at '1' puts the module 
        in line loopback mode, looping
         the received 10 Gb/s signal on 
        the transmit 10 Gb/s output. The 
        Upstream part of the module is
         timed on the 10 Gb/s recovered 
        clock in that case.<Help> This
         control enables the Out Loopback 
        on the line port, looping the 100 
        Gb/s input signal on the 100 Gb/s 
        output
        "
	::= { pme1008CtrllineLoopEntry 2 }


--- *********************************************************
---     TABLE for the pme1008CtrlfecDisable articles
--- *********************************************************

pme1008CtrlfecDisableTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CtrlfecDisableEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008CtrlfecDisable
         Article
        "
	::= { pme1008CtrlLine 69 }


pme1008CtrlfecDisableEntry OBJECT-TYPE
	SYNTAX Pme1008CtrlfecDisableEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008CtrlfecDisable 
        table
        "
	INDEX   { pme1008CtrlfecDisableIndex }
	::= { pme1008CtrlfecDisableTable 1 }


Pme1008CtrlfecDisableEntry ::=
	SEQUENCE {
	pme1008CtrlfecDisableIndex
		INTEGER,
	pme1008CtrlfecDisablePortn
		EkiState
	}


pme1008CtrlfecDisableIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008CtrlfecDisable 
        table
        "
	::= { pme1008CtrlfecDisableEntry 1 }


pme1008CtrlfecDisablePortn OBJECT-TYPE
	SYNTAX  EkiState
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Forward Error Correction Inhibition 
        :This OID, when set, inhibits the 
        Forward Error Correction feature 
        on the line input  <Help>  This 
        control enables/disables the Forward 
        Error Correction on the line interface
        "
	::= { pme1008CtrlfecDisableEntry 2 }


--- *********************************************************
---     TABLE for the pme1008CtrllineBdi articles
--- *********************************************************

pme1008CtrllineBdiTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CtrllineBdiEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008CtrllineBdi Article
        "
	::= { pme1008CtrlLine 70 }


pme1008CtrllineBdiEntry OBJECT-TYPE
	SYNTAX Pme1008CtrllineBdiEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008CtrllineBdi 
        table
        "
	INDEX   { pme1008CtrllineBdiIndex }
	::= { pme1008CtrllineBdiTable 1 }


Pme1008CtrllineBdiEntry ::=
	SEQUENCE {
	pme1008CtrllineBdiIndex
		INTEGER,
	pme1008CtrllineBdiPortn
		EkiState
	}


pme1008CtrllineBdiIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008CtrllineBdi 
        table
        "
	::= { pme1008CtrllineBdiEntry 1 }


pme1008CtrllineBdiPortn OBJECT-TYPE
	SYNTAX  EkiState
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        OTU2e-BDI :Label  <Help>  This 
        control inserts a Line BDI
        "
	::= { pme1008CtrllineBdiEntry 2 }


--- *****************************************************
---     LEAF for the ledTest article
--- *****************************************************
pme1008CtrlledTest OBJECT IDENTIFIER ::= { pme1008CtrlOther 192 }




pme1008CtrlLedOff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Leds Off :This OID switches off 
        all the Leds as a test feature. 
         <Help>  This control initiates 
        a test leds turning all the LEDs 
        to OFF
        "
	  ::= { pme1008CtrlledTest 3 }



pme1008CtrlRedLed OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Red Leds Test :This OID switches 
        on all the red Leds as a test feature. 
         <Help>  This control initiates 
        a test leds turning all the LEDs 
        to red
        "
	  ::= { pme1008CtrlledTest 2 }



pme1008CtrlGreenLed OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Green Leds Test :This OID switches 
        on all the green Leds as a test 
        feature.  <Help>  This control
         initiates a test leds turning
         all the LEDs to green
        "
	  ::= { pme1008CtrlledTest 1 }








--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     COUNTERS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *********************************************************
---     TABLE for the pme1008CntclientCbipCounter articles
--- *********************************************************

pme1008CntclientCbipCounterTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CntclientCbipCounterEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008CntclientCbipCounter 
        Article
        "
	::= { pme1008CntClient 96 }


pme1008CntclientCbipCounterEntry OBJECT-TYPE
	SYNTAX Pme1008CntclientCbipCounterEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008CntclientCbipCounter 
        table
        "
	INDEX   { pme1008CntclientCbipCounterIndex }
	::= { pme1008CntclientCbipCounterTable 1 }


Pme1008CntclientCbipCounterEntry ::=
	SEQUENCE {
	pme1008CntclientCbipCounterIndex
		INTEGER,
	pme1008CntclientCbipCounterValuePortn
		Counter32,
	pme1008CntclientCbipCounterErrorPortn
		EkiOnOff,
	pme1008CntclientCbipCounterOverloadPortn
		EkiOnOff
	}


pme1008CntclientCbipCounterIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008CntclientCbipCounter 
        table
        "
	::= { pme1008CntclientCbipCounterEntry 1 }


pme1008CntclientCbipCounterValuePortn OBJECT-TYPE
	SYNTAX  Counter32
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Output Errors :This counter 
        is incremented each time a BIP
         error is detected on the Client 
        path  <Help>  This counter gives 
        the number of CBIP errors on the 
        client path
        "
	::= { pme1008CntclientCbipCounterEntry 2 }


pme1008CntclientCbipCounterErrorPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Counter Error :This OID 
        when set indicates the CBIP error 
        counter value is invalid on Port
        "
	::= { pme1008CntclientCbipCounterEntry 3 }


pme1008CntclientCbipCounterOverloadPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client CBIP Counter Overload :This 
        OID when set indicates a CBIP error 
        counter overload on Port
        "
	::= { pme1008CntclientCbipCounterEntry 4 }


--- *********************************************************
---     TABLE for the pme1008CntlocalLineSmBip8ErrorCounter articles
--- *********************************************************

pme1008CntlocalLineSmBip8ErrorCounterTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CntlocalLineSmBip8ErrorCounterEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008CntlocalLineSmBip8ErrorCounter 
        Article
        "
	::= { pme1008CntLine 192 }


pme1008CntlocalLineSmBip8ErrorCounterEntry OBJECT-TYPE
	SYNTAX Pme1008CntlocalLineSmBip8ErrorCounterEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008CntlocalLineSmBip8ErrorCounter 
        table
        "
	INDEX   { pme1008CntlocalLineSmBip8ErrorCounterIndex }
	::= { pme1008CntlocalLineSmBip8ErrorCounterTable 1 }


Pme1008CntlocalLineSmBip8ErrorCounterEntry ::=
	SEQUENCE {
	pme1008CntlocalLineSmBip8ErrorCounterIndex
		INTEGER,
	pme1008CntlocalLineSmBip8ErrorCounterValuePortn
		Counter32,
	pme1008CntlocalLineSmBip8ErrorCounterErrorPortn
		EkiOnOff,
	pme1008CntlocalLineSmBip8ErrorCounterOverloadPortn
		EkiOnOff
	}


pme1008CntlocalLineSmBip8ErrorCounterIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008CntlocalLineSmBip8ErrorCounter 
        table
        "
	::= { pme1008CntlocalLineSmBip8ErrorCounterEntry 1 }


pme1008CntlocalLineSmBip8ErrorCounterValuePortn OBJECT-TYPE
	SYNTAX  Counter32
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Input FCS Errors :This counter 
        is increased each time a FCS error 
        is detected on the line input stream 
        <Help>  This counter gives the
         number of FCS errors on the line 
         input port
        "
	::= { pme1008CntlocalLineSmBip8ErrorCounterEntry 2 }


pme1008CntlocalLineSmBip8ErrorCounterErrorPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Counter Error :This OID when 
        set indicates the B1 error counter 
        value is invalid on Port
        "
	::= { pme1008CntlocalLineSmBip8ErrorCounterEntry 3 }


pme1008CntlocalLineSmBip8ErrorCounterOverloadPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Counter Overload :This OID 
        when set indicates a B1 error counter 
        overload on Port
        "
	::= { pme1008CntlocalLineSmBip8ErrorCounterEntry 4 }


--- *********************************************************
---     TABLE for the pme1008CntlineDfrmTimCnt articles
--- *********************************************************

pme1008CntlineDfrmTimCntTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CntlineDfrmTimCntEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008CntlineDfrmTimCnt 
        Article
        "
	::= { pme1008CntLine 216 }


pme1008CntlineDfrmTimCntEntry OBJECT-TYPE
	SYNTAX Pme1008CntlineDfrmTimCntEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008CntlineDfrmTimCnt 
        table
        "
	INDEX   { pme1008CntlineDfrmTimCntIndex }
	::= { pme1008CntlineDfrmTimCntTable 1 }


Pme1008CntlineDfrmTimCntEntry ::=
	SEQUENCE {
	pme1008CntlineDfrmTimCntIndex
		INTEGER,
	pme1008CntlineDfrmTimCntValuePortn
		Counter32,
	pme1008CntlineDfrmTimCntErrorPortn
		EkiOnOff,
	pme1008CntlineDfrmTimCntOverloadPortn
		EkiOnOff
	}


pme1008CntlineDfrmTimCntIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008CntlineDfrmTimCnt 
        table
        "
	::= { pme1008CntlineDfrmTimCntEntry 1 }


pme1008CntlineDfrmTimCntValuePortn OBJECT-TYPE
	SYNTAX  Counter32
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Timer Counter :
        "
	::= { pme1008CntlineDfrmTimCntEntry 2 }


pme1008CntlineDfrmTimCntErrorPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Counter Error :This OID when 
        set indicates the deframer timer 
        counter value is invalid on Port
        "
	::= { pme1008CntlineDfrmTimCntEntry 3 }


pme1008CntlineDfrmTimCntOverloadPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Counter Overload :This OID 
        when set indicates a deframer timer 
        counter overload on Port
        "
	::= { pme1008CntlineDfrmTimCntEntry 4 }


pme1008CntCountersReset  OBJECT-TYPE
	SYNTAX EkiOnOff
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
	"Counters Reset:This OID resets and restarts all the counters"
	::= { pme1008counters  259 }

pme1008CntCountersStop  OBJECT-TYPE
	SYNTAX EkiOnOff
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
	"Counters stop:This OID stops all the counters"
	::= { pme1008counters 260 }






--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     RMON
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *********************************************************
---     TABLE for the pme1008MonupRmonBytesCounterClientInput articles
--- *********************************************************

pme1008MonupRmonBytesCounterClientInputTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008MonupRmonBytesCounterClientInputEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008MonupRmonBytesCounterClientInput 
        Article
        "
	::= { pme1008MonClientRmonCounter 16 }


pme1008MonupRmonBytesCounterClientInputEntry OBJECT-TYPE
	SYNTAX Pme1008MonupRmonBytesCounterClientInputEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008MonupRmonBytesCounterClientInput 
        table
        "
	INDEX   { pme1008MonupRmonBytesCounterClientInputIndex }
	::= { pme1008MonupRmonBytesCounterClientInputTable 1 }


Pme1008MonupRmonBytesCounterClientInputEntry ::=
	SEQUENCE {
	pme1008MonupRmonBytesCounterClientInputIndex
		INTEGER,
	pme1008MonupRmonBytesCounterClientInputValuePortn
		Counter64,
	pme1008MonupRmonBytesCounterClientInputErrorPortn
		EkiOnOff,
	pme1008MonupRmonBytesCounterClientInputOverloadPortn
		EkiOnOff
	}


pme1008MonupRmonBytesCounterClientInputIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008MonupRmonBytesCounterClientInput 
        table
        "
	::= { pme1008MonupRmonBytesCounterClientInputEntry 1 }


pme1008MonupRmonBytesCounterClientInputValuePortn OBJECT-TYPE
	SYNTAX  Counter64
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Input Bytes :This counter 
        is increased each time a data byte 
        is received on the client port
          <Help>  This counter gives the 
        number of bytes received on the 
        client port
        "
	::= { pme1008MonupRmonBytesCounterClientInputEntry 2 }


pme1008MonupRmonBytesCounterClientInputErrorPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Bytes Counter Error :This OID
         when set indicates the Bytes counter 
        value is invalid on client port
        "
	::= { pme1008MonupRmonBytesCounterClientInputEntry 3 }


pme1008MonupRmonBytesCounterClientInputOverloadPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Bytes Counter Overload :This OID 
        when set indicates a Bytes counter 
        overload on client port
        "
	::= { pme1008MonupRmonBytesCounterClientInputEntry 4 }


--- *********************************************************
---     TABLE for the pme1008MonupRmonCrcErrorsCounterClientInput articles
--- *********************************************************

pme1008MonupRmonCrcErrorsCounterClientInputTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008MonupRmonCrcErrorsCounterClientInputEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008MonupRmonCrcErrorsCounterClientInput 
        Article
        "
	::= { pme1008MonClientRmonCounter 32 }


pme1008MonupRmonCrcErrorsCounterClientInputEntry OBJECT-TYPE
	SYNTAX Pme1008MonupRmonCrcErrorsCounterClientInputEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008MonupRmonCrcErrorsCounterClientInput 
        table
        "
	INDEX   { pme1008MonupRmonCrcErrorsCounterClientInputIndex }
	::= { pme1008MonupRmonCrcErrorsCounterClientInputTable 1 }


Pme1008MonupRmonCrcErrorsCounterClientInputEntry ::=
	SEQUENCE {
	pme1008MonupRmonCrcErrorsCounterClientInputIndex
		INTEGER,
	pme1008MonupRmonCrcErrorsCounterClientInputValuePortn
		Counter64,
	pme1008MonupRmonCrcErrorsCounterClientInputErrorPortn
		EkiOnOff,
	pme1008MonupRmonCrcErrorsCounterClientInputOverloadPortn
		EkiOnOff
	}


pme1008MonupRmonCrcErrorsCounterClientInputIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008MonupRmonCrcErrorsCounterClientInput 
        table
        "
	::= { pme1008MonupRmonCrcErrorsCounterClientInputEntry 1 }


pme1008MonupRmonCrcErrorsCounterClientInputValuePortn OBJECT-TYPE
	SYNTAX  Counter64
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Input CRC Errors :This
         counter is increased each time 
        a B1/FCS error is detected on the 
        client port  <Help>  This counter 
        gives the number of B1/FCS Errors 
        received on the client port
        "
	::= { pme1008MonupRmonCrcErrorsCounterClientInputEntry 2 }


pme1008MonupRmonCrcErrorsCounterClientInputErrorPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        B1/FCS Errors Counter Error :This 
        OID when set indicates the B1/FCS 
        Errors counter value is invalid 
        on client port
        "
	::= { pme1008MonupRmonCrcErrorsCounterClientInputEntry 3 }


pme1008MonupRmonCrcErrorsCounterClientInputOverloadPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        B1/FCS Errors Counter Overload 
        :This OID when set indicates a
         B1/FCS Errors counter overload 
        on client port
        "
	::= { pme1008MonupRmonCrcErrorsCounterClientInputEntry 4 }


--- *********************************************************
---     TABLE for the pme1008MonupRmonPacketsCounterClientInput articles
--- *********************************************************

pme1008MonupRmonPacketsCounterClientInputTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008MonupRmonPacketsCounterClientInputEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008MonupRmonPacketsCounterClientInput 
        Article
        "
	::= { pme1008MonClientRmonCounter 48 }


pme1008MonupRmonPacketsCounterClientInputEntry OBJECT-TYPE
	SYNTAX Pme1008MonupRmonPacketsCounterClientInputEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008MonupRmonPacketsCounterClientInput 
        table
        "
	INDEX   { pme1008MonupRmonPacketsCounterClientInputIndex }
	::= { pme1008MonupRmonPacketsCounterClientInputTable 1 }


Pme1008MonupRmonPacketsCounterClientInputEntry ::=
	SEQUENCE {
	pme1008MonupRmonPacketsCounterClientInputIndex
		INTEGER,
	pme1008MonupRmonPacketsCounterClientInputValuePortn
		Counter64,
	pme1008MonupRmonPacketsCounterClientInputErrorPortn
		EkiOnOff,
	pme1008MonupRmonPacketsCounterClientInputOverloadPortn
		EkiOnOff
	}


pme1008MonupRmonPacketsCounterClientInputIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008MonupRmonPacketsCounterClientInput 
        table
        "
	::= { pme1008MonupRmonPacketsCounterClientInputEntry 1 }


pme1008MonupRmonPacketsCounterClientInputValuePortn OBJECT-TYPE
	SYNTAX  Counter64
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Input Packets :This counter 
        is increased each time a packet 
        is received on the client port
          <Help>  This counter gives the 
        number of packets received on the 
        client port
        "
	::= { pme1008MonupRmonPacketsCounterClientInputEntry 2 }


pme1008MonupRmonPacketsCounterClientInputErrorPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Packets Counter Error :This OID 
        when set indicates the Packets
         counter value is invalid on client 
        port
        "
	::= { pme1008MonupRmonPacketsCounterClientInputEntry 3 }


pme1008MonupRmonPacketsCounterClientInputOverloadPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Packets Counter Overload :This 
        OID when set indicates a Packets 
        counter overload on client port
        "
	::= { pme1008MonupRmonPacketsCounterClientInputEntry 4 }


--- *********************************************************
---     TABLE for the pme1008MonupRmonBroadcastCounterClientInput articles
--- *********************************************************

pme1008MonupRmonBroadcastCounterClientInputTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008MonupRmonBroadcastCounterClientInputEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008MonupRmonBroadcastCounterClientInput 
        Article
        "
	::= { pme1008MonClientRmonCounter 64 }


pme1008MonupRmonBroadcastCounterClientInputEntry OBJECT-TYPE
	SYNTAX Pme1008MonupRmonBroadcastCounterClientInputEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008MonupRmonBroadcastCounterClientInput 
        table
        "
	INDEX   { pme1008MonupRmonBroadcastCounterClientInputIndex }
	::= { pme1008MonupRmonBroadcastCounterClientInputTable 1 }


Pme1008MonupRmonBroadcastCounterClientInputEntry ::=
	SEQUENCE {
	pme1008MonupRmonBroadcastCounterClientInputIndex
		INTEGER,
	pme1008MonupRmonBroadcastCounterClientInputValuePortn
		Counter64,
	pme1008MonupRmonBroadcastCounterClientInputErrorPortn
		EkiOnOff,
	pme1008MonupRmonBroadcastCounterClientInputOverloadPortn
		EkiOnOff
	}


pme1008MonupRmonBroadcastCounterClientInputIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008MonupRmonBroadcastCounterClientInput 
        table
        "
	::= { pme1008MonupRmonBroadcastCounterClientInputEntry 1 }


pme1008MonupRmonBroadcastCounterClientInputValuePortn OBJECT-TYPE
	SYNTAX  Counter64
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Input Broadcast Packets 
        :This counter is increased each 
        time a broadcast packet is received 
        on the client port  <Help>  This 
        counter gives the number of Broadcast 
        packets received on the client
         port
        "
	::= { pme1008MonupRmonBroadcastCounterClientInputEntry 2 }


pme1008MonupRmonBroadcastCounterClientInputErrorPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Broadcast Counter Error :This
         OID when set indicates the Broadcast 
        counter value is invalid on client 
        port
        "
	::= { pme1008MonupRmonBroadcastCounterClientInputEntry 3 }


pme1008MonupRmonBroadcastCounterClientInputOverloadPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Broadcast Counter Overload :This 
        OID when set indicates a Broadcast 
        counter overload on client port
        "
	::= { pme1008MonupRmonBroadcastCounterClientInputEntry 4 }


--- *********************************************************
---     TABLE for the pme1008MonupRmonMulticastCounterClientInput articles
--- *********************************************************

pme1008MonupRmonMulticastCounterClientInputTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008MonupRmonMulticastCounterClientInputEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008MonupRmonMulticastCounterClientInput 
        Article
        "
	::= { pme1008MonClientRmonCounter 80 }


pme1008MonupRmonMulticastCounterClientInputEntry OBJECT-TYPE
	SYNTAX Pme1008MonupRmonMulticastCounterClientInputEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008MonupRmonMulticastCounterClientInput 
        table
        "
	INDEX   { pme1008MonupRmonMulticastCounterClientInputIndex }
	::= { pme1008MonupRmonMulticastCounterClientInputTable 1 }


Pme1008MonupRmonMulticastCounterClientInputEntry ::=
	SEQUENCE {
	pme1008MonupRmonMulticastCounterClientInputIndex
		INTEGER,
	pme1008MonupRmonMulticastCounterClientInputValuePortn
		Counter64,
	pme1008MonupRmonMulticastCounterClientInputErrorPortn
		EkiOnOff,
	pme1008MonupRmonMulticastCounterClientInputOverloadPortn
		EkiOnOff
	}


pme1008MonupRmonMulticastCounterClientInputIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008MonupRmonMulticastCounterClientInput 
        table
        "
	::= { pme1008MonupRmonMulticastCounterClientInputEntry 1 }


pme1008MonupRmonMulticastCounterClientInputValuePortn OBJECT-TYPE
	SYNTAX  Counter64
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Input Multicast Packets 
        :This counter is increased each 
        time a Multicast packet is received 
        on the client port  <Help>  This 
        counter gives the number of Multicast 
        packets received on the client
         port
        "
	::= { pme1008MonupRmonMulticastCounterClientInputEntry 2 }


pme1008MonupRmonMulticastCounterClientInputErrorPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Multicast Counter Error :This
         OID when set indicates the Multicast 
        counter value is invalid on client 
        port
        "
	::= { pme1008MonupRmonMulticastCounterClientInputEntry 3 }


pme1008MonupRmonMulticastCounterClientInputOverloadPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Multicast Counter Overload :This 
        OID when set indicates a Multicast 
        counter overload on client port
        "
	::= { pme1008MonupRmonMulticastCounterClientInputEntry 4 }


--- *********************************************************
---     TABLE for the pme1008MonupRmonPauseFrameCounterClientInput articles
--- *********************************************************

pme1008MonupRmonPauseFrameCounterClientInputTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008MonupRmonPauseFrameCounterClientInputEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008MonupRmonPauseFrameCounterClientInput 
        Article
        "
	::= { pme1008MonClientRmonCounter 96 }


pme1008MonupRmonPauseFrameCounterClientInputEntry OBJECT-TYPE
	SYNTAX Pme1008MonupRmonPauseFrameCounterClientInputEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008MonupRmonPauseFrameCounterClientInput 
        table
        "
	INDEX   { pme1008MonupRmonPauseFrameCounterClientInputIndex }
	::= { pme1008MonupRmonPauseFrameCounterClientInputTable 1 }


Pme1008MonupRmonPauseFrameCounterClientInputEntry ::=
	SEQUENCE {
	pme1008MonupRmonPauseFrameCounterClientInputIndex
		INTEGER,
	pme1008MonupRmonPauseFrameCounterClientInputValuePortn
		Counter64,
	pme1008MonupRmonPauseFrameCounterClientInputErrorPortn
		EkiOnOff,
	pme1008MonupRmonPauseFrameCounterClientInputOverloadPortn
		EkiOnOff
	}


pme1008MonupRmonPauseFrameCounterClientInputIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008MonupRmonPauseFrameCounterClientInput 
        table
        "
	::= { pme1008MonupRmonPauseFrameCounterClientInputEntry 1 }


pme1008MonupRmonPauseFrameCounterClientInputValuePortn OBJECT-TYPE
	SYNTAX  Counter64
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Input Pause Frames :This 
        counter is increased each time
         a Pause frame is received on the 
        client port  <Help>  This counter 
        gives the number of Pause frames 
        received on the client port
        "
	::= { pme1008MonupRmonPauseFrameCounterClientInputEntry 2 }


pme1008MonupRmonPauseFrameCounterClientInputErrorPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Pause Counter Error :This OID
         when set indicates the Pause counter 
        value is invalid on client port
        "
	::= { pme1008MonupRmonPauseFrameCounterClientInputEntry 3 }


pme1008MonupRmonPauseFrameCounterClientInputOverloadPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Pause Counter Overload :This OID 
        when set indicates a Pause counter 
        overload on client port
        "
	::= { pme1008MonupRmonPauseFrameCounterClientInputEntry 4 }


--- *********************************************************
---     TABLE for the pme1008MondwRmonCrcErrorsCounterClientOutput articles
--- *********************************************************

pme1008MondwRmonCrcErrorsCounterClientOutputTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008MondwRmonCrcErrorsCounterClientOutputEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008MondwRmonCrcErrorsCounterClientOutput 
        Article
        "
	::= { pme1008MonClientRmonCounter 224 }


pme1008MondwRmonCrcErrorsCounterClientOutputEntry OBJECT-TYPE
	SYNTAX Pme1008MondwRmonCrcErrorsCounterClientOutputEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008MondwRmonCrcErrorsCounterClientOutput 
        table
        "
	INDEX   { pme1008MondwRmonCrcErrorsCounterClientOutputIndex }
	::= { pme1008MondwRmonCrcErrorsCounterClientOutputTable 1 }


Pme1008MondwRmonCrcErrorsCounterClientOutputEntry ::=
	SEQUENCE {
	pme1008MondwRmonCrcErrorsCounterClientOutputIndex
		INTEGER,
	pme1008MondwRmonCrcErrorsCounterClientOutputValuePortn
		Counter64,
	pme1008MondwRmonCrcErrorsCounterClientOutputErrorPortn
		EkiOnOff,
	pme1008MondwRmonCrcErrorsCounterClientOutputOverloadPortn
		EkiOnOff
	}


pme1008MondwRmonCrcErrorsCounterClientOutputIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008MondwRmonCrcErrorsCounterClientOutput 
        table
        "
	::= { pme1008MondwRmonCrcErrorsCounterClientOutputEntry 1 }


pme1008MondwRmonCrcErrorsCounterClientOutputValuePortn OBJECT-TYPE
	SYNTAX  Counter64
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Output B1/CRC Errors :This 
        counter is increased each time
         a B1/FCS error is detected on
         the output client port  <Help> 
         This counter gives the number
         of B1/CRC Errors detected on the 
        client port
        "
	::= { pme1008MondwRmonCrcErrorsCounterClientOutputEntry 2 }


pme1008MondwRmonCrcErrorsCounterClientOutputErrorPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Output B1/FCS Errors Counter Error 
        :This OID when set indicates the 
        output B1/FCS Errors counter value 
        is invalid on client port
        "
	::= { pme1008MondwRmonCrcErrorsCounterClientOutputEntry 3 }


pme1008MondwRmonCrcErrorsCounterClientOutputOverloadPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Output B1/FCS Errors Counter Overload 
        :This OID when set indicates an 
        output B1/FCS Errors counter overload 
        on client port
        "
	::= { pme1008MondwRmonCrcErrorsCounterClientOutputEntry 4 }


--- *********************************************************
---     TABLE for the pme1008MondwRmonPacketsCounterClientOutput articles
--- *********************************************************

pme1008MondwRmonPacketsCounterClientOutputTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008MondwRmonPacketsCounterClientOutputEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008MondwRmonPacketsCounterClientOutput 
        Article
        "
	::= { pme1008MonClientRmonCounter 240 }


pme1008MondwRmonPacketsCounterClientOutputEntry OBJECT-TYPE
	SYNTAX Pme1008MondwRmonPacketsCounterClientOutputEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008MondwRmonPacketsCounterClientOutput 
        table
        "
	INDEX   { pme1008MondwRmonPacketsCounterClientOutputIndex }
	::= { pme1008MondwRmonPacketsCounterClientOutputTable 1 }


Pme1008MondwRmonPacketsCounterClientOutputEntry ::=
	SEQUENCE {
	pme1008MondwRmonPacketsCounterClientOutputIndex
		INTEGER,
	pme1008MondwRmonPacketsCounterClientOutputValuePortn
		Counter64,
	pme1008MondwRmonPacketsCounterClientOutputErrorPortn
		EkiOnOff,
	pme1008MondwRmonPacketsCounterClientOutputOverloadPortn
		EkiOnOff
	}


pme1008MondwRmonPacketsCounterClientOutputIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008MondwRmonPacketsCounterClientOutput 
        table
        "
	::= { pme1008MondwRmonPacketsCounterClientOutputEntry 1 }


pme1008MondwRmonPacketsCounterClientOutputValuePortn OBJECT-TYPE
	SYNTAX  Counter64
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client Output Packets :This counter 
        is increased each time a packet 
        is transmitted on the client port. 
         <Help>  This counter gives the 
        number of packets detected on the 
        client port
        "
	::= { pme1008MondwRmonPacketsCounterClientOutputEntry 2 }


pme1008MondwRmonPacketsCounterClientOutputErrorPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Output Packets Counter Error :This 
        OID when set indicates the output 
        Packets counter value is invalid 
        on client port
        "
	::= { pme1008MondwRmonPacketsCounterClientOutputEntry 3 }


pme1008MondwRmonPacketsCounterClientOutputOverloadPortn OBJECT-TYPE
	SYNTAX  EkiOnOff
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Output Packets Counter Overload 
        :This OID when set indicates an 
        output Packets counter overload 
        on client port
        "
	::= { pme1008MondwRmonPacketsCounterClientOutputEntry 4 }


pme1008MonCountersReset  OBJECT-TYPE
	SYNTAX EkiOnOff
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
	"RMON Counters Reset:This OID resets and restarts all the RMON counters"
	::= { pme1008MonRmon   359 }

pme1008MonCountersStop  OBJECT-TYPE
	SYNTAX EkiOnOff
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
	"RMON Counters stop:This OID stops all the RMON counters"
	::= { pme1008MonRmon  360 }






--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     MEASURES
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *********************************************************
---     TABLE for the pme1008MesrclientTemp articles
--- *********************************************************

pme1008MesrclientTempTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008MesrclientTempEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008MesrclientTemp
         Article
        "
	::= { pme1008MesrClient 16 }


pme1008MesrclientTempEntry OBJECT-TYPE
	SYNTAX Pme1008MesrclientTempEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008MesrclientTemp 
        table
        "
	INDEX   { pme1008MesrclientTempIndex }
	::= { pme1008MesrclientTempTable 1 }


Pme1008MesrclientTempEntry ::=
	SEQUENCE {
	pme1008MesrclientTempIndex
		INTEGER,
	pme1008MesrclientTempPortn
		INTEGER 
	}


pme1008MesrclientTempIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008MesrclientTemp 
        table
        "
	::= { pme1008MesrclientTempEntry 1 }


pme1008MesrclientTempPortn OBJECT-TYPE
	SYNTAX  INTEGER (0..65535)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client SFP Temperature :This OID 
        gives the Laser temperature value 
        of the Client Transceiver, read 
        from the DDM (Digital Diagnostic 
        Monitoring) (Temperature = AV/256) 
        (Unit = C) <Help> This Measure
         gives the Laser temperature value 
        of the Client Transceiver
        "
	::= { pme1008MesrclientTempEntry 2 }


--- *********************************************************
---     TABLE for the pme1008MesrclientTxBias articles
--- *********************************************************

pme1008MesrclientTxBiasTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008MesrclientTxBiasEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008MesrclientTxBias 
        Article
        "
	::= { pme1008MesrClient 32 }


pme1008MesrclientTxBiasEntry OBJECT-TYPE
	SYNTAX Pme1008MesrclientTxBiasEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008MesrclientTxBias 
        table
        "
	INDEX   { pme1008MesrclientTxBiasIndex }
	::= { pme1008MesrclientTxBiasTable 1 }


Pme1008MesrclientTxBiasEntry ::=
	SEQUENCE {
	pme1008MesrclientTxBiasIndex
		INTEGER,
	pme1008MesrclientTxBiasPortn
		INTEGER 
	}


pme1008MesrclientTxBiasIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008MesrclientTxBias 
        table
        "
	::= { pme1008MesrclientTxBiasEntry 1 }


pme1008MesrclientTxBiasPortn OBJECT-TYPE
	SYNTAX  INTEGER (0..65535)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client SFP Laser Bias :This OID 
        gives the Laser bias value of the 
        Client Transceiver, read from the 
        DDM (Digital Diagnostic Monitoring) 
        (Bias = AV/500) (Unit = mA) <Help> 
        This Measure gives the Laser bias 
        value of the Client Transceiver
        "
	::= { pme1008MesrclientTxBiasEntry 2 }


--- *********************************************************
---     TABLE for the pme1008MesrclientTxPwr articles
--- *********************************************************

pme1008MesrclientTxPwrTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008MesrclientTxPwrEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008MesrclientTxPwr 
        Article
        "
	::= { pme1008MesrClient 48 }


pme1008MesrclientTxPwrEntry OBJECT-TYPE
	SYNTAX Pme1008MesrclientTxPwrEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008MesrclientTxPwr 
        table
        "
	INDEX   { pme1008MesrclientTxPwrIndex }
	::= { pme1008MesrclientTxPwrTable 1 }


Pme1008MesrclientTxPwrEntry ::=
	SEQUENCE {
	pme1008MesrclientTxPwrIndex
		INTEGER,
	pme1008MesrclientTxPwrPortn
		INTEGER 
	}


pme1008MesrclientTxPwrIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008MesrclientTxPwr 
        table
        "
	::= { pme1008MesrclientTxPwrEntry 1 }


pme1008MesrclientTxPwrPortn OBJECT-TYPE
	SYNTAX  INTEGER (0..65535)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client SFP Tx Power :This OID
         gives the transmit power value 
        of the Client Transceiver, read 
        from the DDM (Digital Diagnostic 
        Monitoring) (Power = 10*log(AV)-40) 
        (Unit = dBm) <Help> This Measure 
        gives the transmit power value
         of the Client Transceiver
        "
	::= { pme1008MesrclientTxPwrEntry 2 }


--- *********************************************************
---     TABLE for the pme1008MesrclientRxPwr articles
--- *********************************************************

pme1008MesrclientRxPwrTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008MesrclientRxPwrEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008MesrclientRxPwr 
        Article
        "
	::= { pme1008MesrClient 64 }


pme1008MesrclientRxPwrEntry OBJECT-TYPE
	SYNTAX Pme1008MesrclientRxPwrEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008MesrclientRxPwr 
        table
        "
	INDEX   { pme1008MesrclientRxPwrIndex }
	::= { pme1008MesrclientRxPwrTable 1 }


Pme1008MesrclientRxPwrEntry ::=
	SEQUENCE {
	pme1008MesrclientRxPwrIndex
		INTEGER,
	pme1008MesrclientRxPwrPortn
		INTEGER 
	}


pme1008MesrclientRxPwrIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008MesrclientRxPwr 
        table
        "
	::= { pme1008MesrclientRxPwrEntry 1 }


pme1008MesrclientRxPwrPortn OBJECT-TYPE
	SYNTAX  INTEGER (0..65535)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Client SFP Rx Power :This OID
         gives the receive power value
         of the Client Transceiver, read 
        in the DDM (Digital Diagnostic
         Monitoring) (Power = 10*log(AV)-40) 
        (Unit = dBm) <Help> This Measure 
        gives the receive power value of 
        the Client Transceiver
        "
	::= { pme1008MesrclientRxPwrEntry 2 }


--- *********************************************************
---     TABLE for the pme1008MesrlineTxPwr articles
--- *********************************************************

pme1008MesrlineTxPwrTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008MesrlineTxPwrEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008MesrlineTxPwr Article
        "
	::= { pme1008MesrLine 80 }


pme1008MesrlineTxPwrEntry OBJECT-TYPE
	SYNTAX Pme1008MesrlineTxPwrEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008MesrlineTxPwr 
        table
        "
	INDEX   { pme1008MesrlineTxPwrIndex }
	::= { pme1008MesrlineTxPwrTable 1 }


Pme1008MesrlineTxPwrEntry ::=
	SEQUENCE {
	pme1008MesrlineTxPwrIndex
		INTEGER,
	pme1008MesrlineTxPwrPortn
		INTEGER 
	}


pme1008MesrlineTxPwrIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008MesrlineTxPwr 
        table
        "
	::= { pme1008MesrlineTxPwrEntry 1 }


pme1008MesrlineTxPwrPortn OBJECT-TYPE
	SYNTAX  INTEGER (0..65535)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Optical Module Tx Power :This 
        OID gives the Tx Laser transmit 
        power value of the Line Transceiver, 
        read in the DDM (Digital Diagnostic 
        Monitoring) (Power = 10*log(AV)-40) 
        (Unit = dBm) <Help> This Measure 
        gives the Tx Laser transmit power 
        value of the Line Transceiver
        "
	::= { pme1008MesrlineTxPwrEntry 2 }


--- *********************************************************
---     TABLE for the pme1008MesrlineTemp articles
--- *********************************************************

pme1008MesrlineTempTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008MesrlineTempEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008MesrlineTemp Article
        "
	::= { pme1008MesrLine 96 }


pme1008MesrlineTempEntry OBJECT-TYPE
	SYNTAX Pme1008MesrlineTempEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008MesrlineTemp 
        table
        "
	INDEX   { pme1008MesrlineTempIndex }
	::= { pme1008MesrlineTempTable 1 }


Pme1008MesrlineTempEntry ::=
	SEQUENCE {
	pme1008MesrlineTempIndex
		INTEGER,
	pme1008MesrlineTempPortn
		INTEGER 
	}


pme1008MesrlineTempIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008MesrlineTemp 
        table
        "
	::= { pme1008MesrlineTempEntry 1 }


pme1008MesrlineTempPortn OBJECT-TYPE
	SYNTAX  INTEGER (0..65535)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Optical Module Temperature 
        :This OID gives the Tx Laser Temperature 
        value of the Line Transceiver,
         read from the DDM (Digital Diagnostic 
        Monitoring) (Temperature = AV/256) 
        (Unit = C) <Help> This Measure
         gives the Tx Laser Temperature 
        value of the Line Transceiver
        "
	::= { pme1008MesrlineTempEntry 2 }


--- *********************************************************
---     TABLE for the pme1008MesrlineTxBias articles
--- *********************************************************

pme1008MesrlineTxBiasTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008MesrlineTxBiasEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008MesrlineTxBias
         Article
        "
	::= { pme1008MesrLine 112 }


pme1008MesrlineTxBiasEntry OBJECT-TYPE
	SYNTAX Pme1008MesrlineTxBiasEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008MesrlineTxBias 
        table
        "
	INDEX   { pme1008MesrlineTxBiasIndex }
	::= { pme1008MesrlineTxBiasTable 1 }


Pme1008MesrlineTxBiasEntry ::=
	SEQUENCE {
	pme1008MesrlineTxBiasIndex
		INTEGER,
	pme1008MesrlineTxBiasPortn
		INTEGER 
	}


pme1008MesrlineTxBiasIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008MesrlineTxBias 
        table
        "
	::= { pme1008MesrlineTxBiasEntry 1 }


pme1008MesrlineTxBiasPortn OBJECT-TYPE
	SYNTAX  INTEGER (0..65535)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Optical Module Laser Bias 
        :This OID gives the Tx Laser Bias 
        value of the Line Transceiver,
         read from the DDM (Digital Diagnostic 
        Monitoring) (Bias = AV/500) (Unit 
        = mA) <Help> This Measure gives 
        the Tx Laser Bias value of the
         Line Transceiver
        "
	::= { pme1008MesrlineTxBiasEntry 2 }


--- *********************************************************
---     TABLE for the pme1008MesrlineRxPwr articles
--- *********************************************************

pme1008MesrlineRxPwrTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008MesrlineRxPwrEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of pme1008MesrlineRxPwr Article
        "
	::= { pme1008MesrLine 128 }


pme1008MesrlineRxPwrEntry OBJECT-TYPE
	SYNTAX Pme1008MesrlineRxPwrEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the pme1008MesrlineRxPwr 
        table
        "
	INDEX   { pme1008MesrlineRxPwrIndex }
	::= { pme1008MesrlineRxPwrTable 1 }


Pme1008MesrlineRxPwrEntry ::=
	SEQUENCE {
	pme1008MesrlineRxPwrIndex
		INTEGER,
	pme1008MesrlineRxPwrPortn
		INTEGER 
	}


pme1008MesrlineRxPwrIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the pme1008MesrlineRxPwr 
        table
        "
	::= { pme1008MesrlineRxPwrEntry 1 }


pme1008MesrlineRxPwrPortn OBJECT-TYPE
	SYNTAX  INTEGER (0..65535)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Line Optical Module Rx Power :This 
        OID gives the Receive power value 
        of the Line Transceiver, read in 
        the DDM (Digital Diagnostic Monitoring) 
        (Power = 10*log(AV)-40) (Unit = 
        dBm) <Help> This Measure gives
         the Receive power value of the 
        Line Transceiver
        "
	::= { pme1008MesrlineRxPwrEntry 2 }







--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     DOWNLOAD
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the restartProcess article
--- *****************************************************
pme1008DwlrestartProcess OBJECT IDENTIFIER ::= { pme1008DwlOther 0 }




pme1008DwlColdRestartProcessed OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Cold Restart :This OID indicates 
        that the module last restart was 
        a Cold RESTART
        "
	  ::= { pme1008DwlrestartProcess 2 }



pme1008DwlWarmRestartProcessed OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Warm Restart :This OID indicates 
        that the module last restart was 
        a Warm RESTART
        "
	  ::= { pme1008DwlrestartProcess 1 }



--- *****************************************************
---     LEAF for the swBanksUsed article
--- *****************************************************
pme1008DwlswBanksUsed OBJECT IDENTIFIER ::= { pme1008DwlOther 1 }




pme1008DwlSwBank2Notempty OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        SW bank 2 loaded :This OID indicates 
        a software is loaded in SW bank 
        2  <Help>  This status indicates 
        if the SW bank 2 contains SW package
        "
	  ::= { pme1008DwlswBanksUsed 6 }



pme1008DwlSwBank1Notempty OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        SW bank 1 loaded :This OID indicates 
        a software is loaded in SW bank 
        1  <Help>  This status indicates 
        if the SW bank 1 contains SW package
        "
	  ::= { pme1008DwlswBanksUsed 5 }



pme1008DwlSwBank2Used OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        SW bank 2 active :This OID indicates 
        the module is working on SW bank 
        2  <Help>  This status indicates 
        if the SW bank 2 is active or standby
        "
	  ::= { pme1008DwlswBanksUsed 2 }



pme1008DwlSwBank1Used OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        SW bank 1 active :This OID indicates 
        the module is working on SW bank 
        1  <Help>  This status indicates 
        if the SW bank 1 is active or standby
        "
	  ::= { pme1008DwlswBanksUsed 1 }



--- *****************************************************
---     LEAF for the gwBanksUsed article
--- *****************************************************
pme1008DwlgwBanksUsed OBJECT IDENTIFIER ::= { pme1008DwlOther 2 }




pme1008DwlGwBank4Notempty OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        GW bank 4 loaded :This OID indicates 
        a gateware is loaded in GW bank 
        4
        "
	  ::= { pme1008DwlgwBanksUsed 8 }



pme1008DwlGwBank3Notempty OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        GW bank 3 loaded :This OID indicates 
        a gateware is loaded in GW bank 
        3  <Help>  This status indicates 
        if the GW bank 3 contains GW package
        "
	  ::= { pme1008DwlgwBanksUsed 7 }



pme1008DwlGwBank2Notempty OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        GW bank 2 loaded :This OID indicates 
        a gateware is loaded in GW bank 
        2
        "
	  ::= { pme1008DwlgwBanksUsed 6 }



pme1008DwlGwBank1Notempty OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        GW bank 1 loaded :This OID indicates 
        a gateware is loaded in GW bank 
        1  <Help>  This status indicates 
        if the GW bank 1 contains GW package
        "
	  ::= { pme1008DwlgwBanksUsed 5 }



pme1008DwlGwBank4Used OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        GW bank 4 active :This OID indicates 
        the module is working on GW bank 
        4
        "
	  ::= { pme1008DwlgwBanksUsed 4 }



pme1008DwlGwBank3Used OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        GW bank 3 active :This OID indicates 
        the module is working on GW bank 
        3  <Help>  This status indicates 
        if the GW bank 3 is active or standby
        "
	  ::= { pme1008DwlgwBanksUsed 3 }



pme1008DwlGwBank2Used OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        GW bank 2 active :This OID indicates 
        the module is working on GW bank 
        2
        "
	  ::= { pme1008DwlgwBanksUsed 2 }



pme1008DwlGwBank1Used OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        GW bank 1 active :This OID indicates 
        the module is working on GW bank 
        1  <Help>  This status indicates 
        if the GW bank 1 is active or standby
        "
	  ::= { pme1008DwlgwBanksUsed 1 }








--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     CONFIG
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the table Group startup
--- *****************************************************

pme1008CfgStartup OBJECT IDENTIFIER ::= { pme1008Config 1 }



--- *****************************************************
---     LEAF for the table 2110
--- *****************************************************

pme1008CfgClientStartupTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CfgClientStartupEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pme1008CfgStartup 1 }


pme1008CfgClientStartupEntry OBJECT-TYPE
	SYNTAX Pme1008CfgClientStartupEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the startup 
        table
        "
	INDEX   { pme1008CfgClientStartupIndex }
	::= { pme1008CfgClientStartupTable 1 }


Pme1008CfgClientStartupEntry ::=
	SEQUENCE {
	pme1008CfgClientStartupIndex
		INTEGER,
	pme1008CfgSystConfPortPortn
		Unsigned32,
	pme1008CfgNetConfPortPortn
		Unsigned32,
	pme1008CfgOptionsPortPortn
		Unsigned32
	}


pme1008CfgClientStartupIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the clientStartup 
        table
        "
	::= { pme1008CfgClientStartupEntry 1 }


pme1008CfgSystConfPortPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default Settings on Client Port 
        :This  register configures the
         default initialisation settings 
        on the port.
        "
	::= { pme1008CfgClientStartupEntry 3 }


pme1008CfgNetConfPortPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default Settings on Client Port 
        :This  register configures the
         default initialisation settings 
        on the port.
        "
	::= { pme1008CfgClientStartupEntry 4 }


pme1008CfgOptionsPortPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default Options on Client Port 
        :This register configures the default 
        options on the port.
        "
	::= { pme1008CfgClientStartupEntry 14 }


--- *****************************************************
---     LEAF for the table 2190
--- *****************************************************

pme1008CfgLinexr1StartupTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CfgLinexr1StartupEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pme1008CfgStartup 2 }


pme1008CfgLinexr1StartupEntry OBJECT-TYPE
	SYNTAX Pme1008CfgLinexr1StartupEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the startup 
        table
        "
	INDEX   { pme1008CfgLinexr1StartupIndex }
	::= { pme1008CfgLinexr1StartupTable 1 }


Pme1008CfgLinexr1StartupEntry ::=
	SEQUENCE {
	pme1008CfgLinexr1StartupIndex
		INTEGER,
	pme1008CfgSystConfLinePortn
		Unsigned32,
	pme1008CfgOptionsLinePortn
		Unsigned32
	}


pme1008CfgLinexr1StartupIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the linexr1Startup 
        table
        "
	::= { pme1008CfgLinexr1StartupEntry 1 }


pme1008CfgSystConfLinePortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default Settings on Line :This 
        register configures the default 
        initialisation settings on Line
        "
	::= { pme1008CfgLinexr1StartupEntry 3 }


pme1008CfgOptionsLinePortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default Options on Line :This
         register configures the default 
        options on the line
        "
	::= { pme1008CfgLinexr1StartupEntry 14 }


--- *****************************************************
---     LEAF for the table 2710
--- *****************************************************

pme1008CfgOtxtlhTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CfgOtxtlhEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pme1008CfgStartup 3 }


pme1008CfgOtxtlhEntry OBJECT-TYPE
	SYNTAX Pme1008CfgOtxtlhEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the startup 
        table
        "
	INDEX   { pme1008CfgOtxtlhIndex }
	::= { pme1008CfgOtxtlhTable 1 }


Pme1008CfgOtxtlhEntry ::=
	SEQUENCE {
	pme1008CfgOtxtlhIndex
		INTEGER,
	pme1008CfgLineControlsPortn
		Unsigned32,
	pme1008CfgLinePwrLaserPortn
		Unsigned32,
	pme1008CfgLineFCurrentPortn
		Unsigned32,
	pme1008CfgLineGridCurrentPortn
		Unsigned32,
	pme1008CfgLineFoPortn
		Unsigned32
	}


pme1008CfgOtxtlhIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the otxtlh 
        table
        "
	::= { pme1008CfgOtxtlhEntry 1 }


pme1008CfgLineControlsPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-write
	STATUS deprecated
	DESCRIPTION
        "
        Default Line settings :This register 
        configures the start-up settings 
        on the ports
        "
	::= { pme1008CfgOtxtlhEntry 3 }


pme1008CfgLinePwrLaserPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default Line output Power :This 
        register configures the start-up 
        output power of the client transceiver 
         (Unit = dBm)
        "
	::= { pme1008CfgOtxtlhEntry 6 }


pme1008CfgLineFCurrentPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default Line transceiver Channel 
        :This register configures the start-up 
        laser channel of the client  transceiver
        "
	::= { pme1008CfgOtxtlhEntry 7 }


pme1008CfgLineGridCurrentPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default Line transceiver Grid
         :This register configures the
         start-up laser grid of the client 
        transceiver
        "
	::= { pme1008CfgOtxtlhEntry 8 }


pme1008CfgLineFoPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default Line first Frequency :This 
        register configures the start-up 
        first frequency of the client transceiver
        "
	::= { pme1008CfgOtxtlhEntry 9 }


--- *****************************************************
---     LEAF for the table Group labels
--- *****************************************************

pme1008CfgLabels OBJECT IDENTIFIER ::= { pme1008Config 2 }



--- *****************************************************
---     LEAF for the table 0003
--- *****************************************************

pme1008CfgLabelclientTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CfgLabelclientEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pme1008CfgLabels 1 }


pme1008CfgLabelclientEntry OBJECT-TYPE
	SYNTAX Pme1008CfgLabelclientEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the labels
         table
        "
	INDEX   { pme1008CfgLabelclientIndex }
	::= { pme1008CfgLabelclientTable 1 }


Pme1008CfgLabelclientEntry ::=
	SEQUENCE {
	pme1008CfgLabelclientIndex
		INTEGER,
	pme1008CfgLabelclientPortn
		DisplayString
	}


pme1008CfgLabelclientIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the labelclient 
        table
        "
	::= { pme1008CfgLabelclientEntry 1 }


pme1008CfgLabelclientPortn OBJECT-TYPE
	SYNTAX  DisplayString( SIZE(1..16))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default settings on the label
         of the Ports :These registers
         configures the default initialisation 
        settings of the labels of the ports.
        "
	::= { pme1008CfgLabelclientEntry 3 }


--- *****************************************************
---     LEAF for the table 0004
--- *****************************************************

pme1008CfgLabellineTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CfgLabellineEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pme1008CfgLabels 2 }


pme1008CfgLabellineEntry OBJECT-TYPE
	SYNTAX Pme1008CfgLabellineEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the labels
         table
        "
	INDEX   { pme1008CfgLabellineIndex }
	::= { pme1008CfgLabellineTable 1 }


Pme1008CfgLabellineEntry ::=
	SEQUENCE {
	pme1008CfgLabellineIndex
		INTEGER,
	pme1008CfgLabellinePortn
		DisplayString
	}


pme1008CfgLabellineIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the labelline 
        table
        "
	::= { pme1008CfgLabellineEntry 1 }


pme1008CfgLabellinePortn OBJECT-TYPE
	SYNTAX  DisplayString( SIZE(1..16))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default settings on the label
         of the lines :These registers
         configures the default initialisation 
        settings of the labels of the lines.
        "
	::= { pme1008CfgLabellineEntry 3 }


--- *****************************************************
---     LEAF for the table Group other
--- *****************************************************

pme1008CfgOther OBJECT IDENTIFIER ::= { pme1008Config 3 }



--- *****************************************************
---     LEAF for the table 2300
--- *****************************************************

pme1008tablemoduleOther OBJECT IDENTIFIER ::= { pme1008CfgOther 1 }



pme1008Cfgmode OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default settings on Module :This 
        register selects the configuration 
        mode of the module
        "
	  ::= { pme1008tablemoduleOther 2 }



--- *****************************************************
---     LEAF for the table Group odu2Clienta
--- *****************************************************

pme1008CfgOdu2Clienta OBJECT IDENTIFIER ::= { pme1008Config 4 }



--- *****************************************************
---     LEAF for the table 29C0
--- *****************************************************

pme1008CfgClientStartupOduTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CfgClientStartupOduEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pme1008CfgOdu2Clienta 1 }


pme1008CfgClientStartupOduEntry OBJECT-TYPE
	SYNTAX Pme1008CfgClientStartupOduEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the odu2Clienta 
        table
        "
	INDEX   { pme1008CfgClientStartupOduIndex }
	::= { pme1008CfgClientStartupOduTable 1 }


Pme1008CfgClientStartupOduEntry ::=
	SEQUENCE {
	pme1008CfgClientStartupOduIndex
		INTEGER,
	pme1008CfgOdu2ReserveLsbPortn
		Unsigned32,
	pme1008CfgOdu2DegthresholdPortn
		Unsigned32,
	pme1008CfgOdu2DegmPortn
		Unsigned32,
	pme1008CfgOdu2SettingsPortn
		Unsigned32
	}


pme1008CfgClientStartupOduIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the clientStartupOdu 
        table
        "
	::= { pme1008CfgClientStartupOduEntry 1 }


pme1008CfgOdu2ReserveLsbPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        :
        "
	::= { pme1008CfgClientStartupOduEntry 3 }


pme1008CfgOdu2DegthresholdPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        ODU2 Degrade Threshold :
        "
	::= { pme1008CfgClientStartupOduEntry 4 }


pme1008CfgOdu2DegmPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        ODU2 Degrade Confirmation :
        "
	::= { pme1008CfgClientStartupOduEntry 5 }


pme1008CfgOdu2SettingsPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        ODU2 Settings :
        "
	::= { pme1008CfgClientStartupOduEntry 6 }


--- *****************************************************
---     LEAF for the table Group otu2Line
--- *****************************************************

pme1008CfgOtu2Line OBJECT IDENTIFIER ::= { pme1008Config 5 }



--- *****************************************************
---     LEAF for the table 29E0
--- *****************************************************

pme1008CfgLinexStartupOtuTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CfgLinexStartupOtuEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pme1008CfgOtu2Line 1 }


pme1008CfgLinexStartupOtuEntry OBJECT-TYPE
	SYNTAX Pme1008CfgLinexStartupOtuEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the otu2Line 
        table
        "
	INDEX   { pme1008CfgLinexStartupOtuIndex }
	::= { pme1008CfgLinexStartupOtuTable 1 }


Pme1008CfgLinexStartupOtuEntry ::=
	SEQUENCE {
	pme1008CfgLinexStartupOtuIndex
		INTEGER,
	pme1008CfgOtu2ReserveMsbPortn
		Unsigned32,
	pme1008CfgOtu2DegthresholdPortn
		Unsigned32,
	pme1008CfgOtu2DegmPortn
		Unsigned32,
	pme1008CfgOtu2SettingsPortn
		Unsigned32
	}


pme1008CfgLinexStartupOtuIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the linexStartupOtu 
        table
        "
	::= { pme1008CfgLinexStartupOtuEntry 1 }


pme1008CfgOtu2ReserveMsbPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        :
        "
	::= { pme1008CfgLinexStartupOtuEntry 3 }


pme1008CfgOtu2DegthresholdPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        OTU2 Degrade Threshold :
        "
	::= { pme1008CfgLinexStartupOtuEntry 4 }


pme1008CfgOtu2DegmPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        OTU2 Degrade Confirmation :
        "
	::= { pme1008CfgLinexStartupOtuEntry 5 }


pme1008CfgOtu2SettingsPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        OTU2 Settings :
        "
	::= { pme1008CfgLinexStartupOtuEntry 6 }


--- *****************************************************
---     LEAF for the table Group sapiTxClient
--- *****************************************************

pme1008CfgSapiTxClient OBJECT IDENTIFIER ::= { pme1008Config 6 }



--- *****************************************************
---     LEAF for the table 2A10
--- *****************************************************

pme1008CfgClientSapiTxOduTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CfgClientSapiTxOduEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pme1008CfgSapiTxClient 1 }


pme1008CfgClientSapiTxOduEntry OBJECT-TYPE
	SYNTAX Pme1008CfgClientSapiTxOduEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the sapiTxClient 
        table
        "
	INDEX   { pme1008CfgClientSapiTxOduIndex }
	::= { pme1008CfgClientSapiTxOduTable 1 }


Pme1008CfgClientSapiTxOduEntry ::=
	SEQUENCE {
	pme1008CfgClientSapiTxOduIndex
		INTEGER,
	pme1008CfgClientSapiTxSetupPortn
		DisplayString
	}


pme1008CfgClientSapiTxOduIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the clientSapiTxOdu 
        table
        "
	::= { pme1008CfgClientSapiTxOduEntry 1 }


pme1008CfgClientSapiTxSetupPortn OBJECT-TYPE
	SYNTAX  DisplayString( SIZE(1..16))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Client Transmitted SAPI :This
         register defines the value of
         the transmitted Trace Identifier 
        on the line output
        "
	::= { pme1008CfgClientSapiTxOduEntry 3 }


--- *****************************************************
---     LEAF for the table Group sapiExpClient
--- *****************************************************

pme1008CfgSapiExpClient OBJECT IDENTIFIER ::= { pme1008Config 7 }



--- *****************************************************
---     LEAF for the table 2A30
--- *****************************************************

pme1008CfgClientSapiExpOduTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CfgClientSapiExpOduEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pme1008CfgSapiExpClient 1 }


pme1008CfgClientSapiExpOduEntry OBJECT-TYPE
	SYNTAX Pme1008CfgClientSapiExpOduEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the sapiExpClient 
        table
        "
	INDEX   { pme1008CfgClientSapiExpOduIndex }
	::= { pme1008CfgClientSapiExpOduTable 1 }


Pme1008CfgClientSapiExpOduEntry ::=
	SEQUENCE {
	pme1008CfgClientSapiExpOduIndex
		INTEGER,
	pme1008CfgClientSapiExpSetupPortn
		DisplayString
	}


pme1008CfgClientSapiExpOduIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the clientSapiExpOdu 
        table
        "
	::= { pme1008CfgClientSapiExpOduEntry 1 }


pme1008CfgClientSapiExpSetupPortn OBJECT-TYPE
	SYNTAX  DisplayString( SIZE(1..16))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Client Expected SAPI :This register 
        defines the value of the expected 
        Trace Identifier on the line input
        "
	::= { pme1008CfgClientSapiExpOduEntry 3 }


--- *****************************************************
---     LEAF for the table Group sapiAccClient
--- *****************************************************

pme1008CfgSapiAccClient OBJECT IDENTIFIER ::= { pme1008Config 8 }



--- *****************************************************
---     LEAF for the table 2A50
--- *****************************************************

pme1008CfgClientSapiAccOduTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CfgClientSapiAccOduEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pme1008CfgSapiAccClient 1 }


pme1008CfgClientSapiAccOduEntry OBJECT-TYPE
	SYNTAX Pme1008CfgClientSapiAccOduEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the sapiAccClient 
        table
        "
	INDEX   { pme1008CfgClientSapiAccOduIndex }
	::= { pme1008CfgClientSapiAccOduTable 1 }


Pme1008CfgClientSapiAccOduEntry ::=
	SEQUENCE {
	pme1008CfgClientSapiAccOduIndex
		INTEGER,
	pme1008CfgClientSapiAccSetupPortn
		DisplayString
	}


pme1008CfgClientSapiAccOduIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the clientSapiAccOdu 
        table
        "
	::= { pme1008CfgClientSapiAccOduEntry 1 }


pme1008CfgClientSapiAccSetupPortn OBJECT-TYPE
	SYNTAX  DisplayString( SIZE(1..16))
	MAX-ACCESS read-write
	STATUS deprecated
	DESCRIPTION
        "
        Client Accepted SAPI :This register 
        defines the value of the accepted 
        Trace Identifier on the line input
        "
	::= { pme1008CfgClientSapiAccOduEntry 3 }


--- *****************************************************
---     LEAF for the table Group dapiTxClient
--- *****************************************************

pme1008CfgDapiTxClient OBJECT IDENTIFIER ::= { pme1008Config 9 }



--- *****************************************************
---     LEAF for the table 2A90
--- *****************************************************

pme1008CfgClientDapiTxOduTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CfgClientDapiTxOduEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pme1008CfgDapiTxClient 1 }


pme1008CfgClientDapiTxOduEntry OBJECT-TYPE
	SYNTAX Pme1008CfgClientDapiTxOduEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the dapiTxClient 
        table
        "
	INDEX   { pme1008CfgClientDapiTxOduIndex }
	::= { pme1008CfgClientDapiTxOduTable 1 }


Pme1008CfgClientDapiTxOduEntry ::=
	SEQUENCE {
	pme1008CfgClientDapiTxOduIndex
		INTEGER,
	pme1008CfgClientDapiTxSetupPortn
		DisplayString
	}


pme1008CfgClientDapiTxOduIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the clientDapiTxOdu 
        table
        "
	::= { pme1008CfgClientDapiTxOduEntry 1 }


pme1008CfgClientDapiTxSetupPortn OBJECT-TYPE
	SYNTAX  DisplayString( SIZE(1..16))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Client Transmitted DAPI :This
         register defines the value of
         the transmitted Trace Identifier 
        on the line output
        "
	::= { pme1008CfgClientDapiTxOduEntry 3 }


--- *****************************************************
---     LEAF for the table Group dapiExpClient
--- *****************************************************

pme1008CfgDapiExpClient OBJECT IDENTIFIER ::= { pme1008Config 10 }



--- *****************************************************
---     LEAF for the table 2AB0
--- *****************************************************

pme1008CfgClientDapiExpOduTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CfgClientDapiExpOduEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pme1008CfgDapiExpClient 1 }


pme1008CfgClientDapiExpOduEntry OBJECT-TYPE
	SYNTAX Pme1008CfgClientDapiExpOduEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the dapiExpClient 
        table
        "
	INDEX   { pme1008CfgClientDapiExpOduIndex }
	::= { pme1008CfgClientDapiExpOduTable 1 }


Pme1008CfgClientDapiExpOduEntry ::=
	SEQUENCE {
	pme1008CfgClientDapiExpOduIndex
		INTEGER,
	pme1008CfgClientDapiExpSetupPortn
		DisplayString
	}


pme1008CfgClientDapiExpOduIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the clientDapiExpOdu 
        table
        "
	::= { pme1008CfgClientDapiExpOduEntry 1 }


pme1008CfgClientDapiExpSetupPortn OBJECT-TYPE
	SYNTAX  DisplayString( SIZE(1..16))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Client Expected DAPI :This register 
        defines the value of the expected 
        Trace Identifier on the line input
        "
	::= { pme1008CfgClientDapiExpOduEntry 3 }


--- *****************************************************
---     LEAF for the table Group dapiAccClient
--- *****************************************************

pme1008CfgDapiAccClient OBJECT IDENTIFIER ::= { pme1008Config 11 }



--- *****************************************************
---     LEAF for the table 2AD0
--- *****************************************************

pme1008CfgClientDapiAccOduTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CfgClientDapiAccOduEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pme1008CfgDapiAccClient 1 }


pme1008CfgClientDapiAccOduEntry OBJECT-TYPE
	SYNTAX Pme1008CfgClientDapiAccOduEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the dapiAccClient 
        table
        "
	INDEX   { pme1008CfgClientDapiAccOduIndex }
	::= { pme1008CfgClientDapiAccOduTable 1 }


Pme1008CfgClientDapiAccOduEntry ::=
	SEQUENCE {
	pme1008CfgClientDapiAccOduIndex
		INTEGER,
	pme1008CfgClientDapiAccSetupPortn
		DisplayString
	}


pme1008CfgClientDapiAccOduIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the clientDapiAccOdu 
        table
        "
	::= { pme1008CfgClientDapiAccOduEntry 1 }


pme1008CfgClientDapiAccSetupPortn OBJECT-TYPE
	SYNTAX  DisplayString( SIZE(1..16))
	MAX-ACCESS read-write
	STATUS deprecated
	DESCRIPTION
        "
        Client Accepted DAPI :This register 
        defines the value of the accepted 
        Trace Identifier on the line input
        "
	::= { pme1008CfgClientDapiAccOduEntry 3 }


--- *****************************************************
---     LEAF for the table Group sapiTxLine
--- *****************************************************

pme1008CfgSapiTxLine OBJECT IDENTIFIER ::= { pme1008Config 12 }



--- *****************************************************
---     LEAF for the table 2B10
--- *****************************************************

pme1008CfgLineSapiTxOtuTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CfgLineSapiTxOtuEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pme1008CfgSapiTxLine 1 }


pme1008CfgLineSapiTxOtuEntry OBJECT-TYPE
	SYNTAX Pme1008CfgLineSapiTxOtuEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the sapiTxLine 
        table
        "
	INDEX   { pme1008CfgLineSapiTxOtuIndex }
	::= { pme1008CfgLineSapiTxOtuTable 1 }


Pme1008CfgLineSapiTxOtuEntry ::=
	SEQUENCE {
	pme1008CfgLineSapiTxOtuIndex
		INTEGER,
	pme1008CfgLineSapiTxSetupPortn
		DisplayString
	}


pme1008CfgLineSapiTxOtuIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the lineSapiTxOtu 
        table
        "
	::= { pme1008CfgLineSapiTxOtuEntry 1 }


pme1008CfgLineSapiTxSetupPortn OBJECT-TYPE
	SYNTAX  DisplayString( SIZE(1..16))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Line Transmitted SAPI :This register 
        defines the value of the transmitted 
        Trace Identifier on the line output
        "
	::= { pme1008CfgLineSapiTxOtuEntry 3 }


--- *****************************************************
---     LEAF for the table Group sapiExpLine
--- *****************************************************

pme1008CfgSapiExpLine OBJECT IDENTIFIER ::= { pme1008Config 13 }



--- *****************************************************
---     LEAF for the table 2B30
--- *****************************************************

pme1008CfgLineSapiExpOtuTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CfgLineSapiExpOtuEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pme1008CfgSapiExpLine 1 }


pme1008CfgLineSapiExpOtuEntry OBJECT-TYPE
	SYNTAX Pme1008CfgLineSapiExpOtuEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the sapiExpLine 
        table
        "
	INDEX   { pme1008CfgLineSapiExpOtuIndex }
	::= { pme1008CfgLineSapiExpOtuTable 1 }


Pme1008CfgLineSapiExpOtuEntry ::=
	SEQUENCE {
	pme1008CfgLineSapiExpOtuIndex
		INTEGER,
	pme1008CfgLineSapiExpSetupPortn
		DisplayString
	}


pme1008CfgLineSapiExpOtuIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the lineSapiExpOtu 
        table
        "
	::= { pme1008CfgLineSapiExpOtuEntry 1 }


pme1008CfgLineSapiExpSetupPortn OBJECT-TYPE
	SYNTAX  DisplayString( SIZE(1..16))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Line Expected SAPI :This register 
        defines the value of the expected 
        Trace Identifier on the line input
        "
	::= { pme1008CfgLineSapiExpOtuEntry 3 }


--- *****************************************************
---     LEAF for the table Group sapiAccLine
--- *****************************************************

pme1008CfgSapiAccLine OBJECT IDENTIFIER ::= { pme1008Config 14 }



--- *****************************************************
---     LEAF for the table 2B50
--- *****************************************************

pme1008CfgLineSapiAccOtuTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CfgLineSapiAccOtuEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pme1008CfgSapiAccLine 1 }


pme1008CfgLineSapiAccOtuEntry OBJECT-TYPE
	SYNTAX Pme1008CfgLineSapiAccOtuEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the sapiAccLine 
        table
        "
	INDEX   { pme1008CfgLineSapiAccOtuIndex }
	::= { pme1008CfgLineSapiAccOtuTable 1 }


Pme1008CfgLineSapiAccOtuEntry ::=
	SEQUENCE {
	pme1008CfgLineSapiAccOtuIndex
		INTEGER,
	pme1008CfgLineSapiAccSetupPortn
		DisplayString
	}


pme1008CfgLineSapiAccOtuIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the lineSapiAccOtu 
        table
        "
	::= { pme1008CfgLineSapiAccOtuEntry 1 }


pme1008CfgLineSapiAccSetupPortn OBJECT-TYPE
	SYNTAX  DisplayString( SIZE(1..16))
	MAX-ACCESS read-write
	STATUS deprecated
	DESCRIPTION
        "
        Line Accepted SAPI :This register 
        defines the value of the accepted 
        Trace Identifier on the line input
        "
	::= { pme1008CfgLineSapiAccOtuEntry 3 }


--- *****************************************************
---     LEAF for the table Group dapiTxLine
--- *****************************************************

pme1008CfgDapiTxLine OBJECT IDENTIFIER ::= { pme1008Config 15 }



--- *****************************************************
---     LEAF for the table 2B90
--- *****************************************************

pme1008CfgLineDapiTxOtuTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CfgLineDapiTxOtuEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pme1008CfgDapiTxLine 1 }


pme1008CfgLineDapiTxOtuEntry OBJECT-TYPE
	SYNTAX Pme1008CfgLineDapiTxOtuEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the dapiTxLine 
        table
        "
	INDEX   { pme1008CfgLineDapiTxOtuIndex }
	::= { pme1008CfgLineDapiTxOtuTable 1 }


Pme1008CfgLineDapiTxOtuEntry ::=
	SEQUENCE {
	pme1008CfgLineDapiTxOtuIndex
		INTEGER,
	pme1008CfgLineDapiTxSetupPortn
		DisplayString
	}


pme1008CfgLineDapiTxOtuIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the lineDapiTxOtu 
        table
        "
	::= { pme1008CfgLineDapiTxOtuEntry 1 }


pme1008CfgLineDapiTxSetupPortn OBJECT-TYPE
	SYNTAX  DisplayString( SIZE(1..16))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Line Transmitted DAPI :This register 
        defines the value of the transmitted 
        Trace Identifier on the line output
        "
	::= { pme1008CfgLineDapiTxOtuEntry 3 }


--- *****************************************************
---     LEAF for the table Group dapiExpLine
--- *****************************************************

pme1008CfgDapiExpLine OBJECT IDENTIFIER ::= { pme1008Config 16 }



--- *****************************************************
---     LEAF for the table 2BB0
--- *****************************************************

pme1008CfgLineDapiExpOtuTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CfgLineDapiExpOtuEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pme1008CfgDapiExpLine 1 }


pme1008CfgLineDapiExpOtuEntry OBJECT-TYPE
	SYNTAX Pme1008CfgLineDapiExpOtuEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the dapiExpLine 
        table
        "
	INDEX   { pme1008CfgLineDapiExpOtuIndex }
	::= { pme1008CfgLineDapiExpOtuTable 1 }


Pme1008CfgLineDapiExpOtuEntry ::=
	SEQUENCE {
	pme1008CfgLineDapiExpOtuIndex
		INTEGER,
	pme1008CfgLineDapiExpSetupPortn
		DisplayString
	}


pme1008CfgLineDapiExpOtuIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the lineDapiExpOtu 
        table
        "
	::= { pme1008CfgLineDapiExpOtuEntry 1 }


pme1008CfgLineDapiExpSetupPortn OBJECT-TYPE
	SYNTAX  DisplayString( SIZE(1..16))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Line Expected DAPI :This register 
        defines the value of the expected 
        Trace Identifier on the line input
        "
	::= { pme1008CfgLineDapiExpOtuEntry 3 }


--- *****************************************************
---     LEAF for the table Group dapiAccLine
--- *****************************************************

pme1008CfgDapiAccLine OBJECT IDENTIFIER ::= { pme1008Config 17 }



--- *****************************************************
---     LEAF for the table 2BD0
--- *****************************************************

pme1008CfgLineDapiAccOtuTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CfgLineDapiAccOtuEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pme1008CfgDapiAccLine 1 }


pme1008CfgLineDapiAccOtuEntry OBJECT-TYPE
	SYNTAX Pme1008CfgLineDapiAccOtuEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the dapiAccLine 
        table
        "
	INDEX   { pme1008CfgLineDapiAccOtuIndex }
	::= { pme1008CfgLineDapiAccOtuTable 1 }


Pme1008CfgLineDapiAccOtuEntry ::=
	SEQUENCE {
	pme1008CfgLineDapiAccOtuIndex
		INTEGER,
	pme1008CfgLineDapiAccSetupPortn
		DisplayString
	}


pme1008CfgLineDapiAccOtuIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the lineDapiAccOtu 
        table
        "
	::= { pme1008CfgLineDapiAccOtuEntry 1 }


pme1008CfgLineDapiAccSetupPortn OBJECT-TYPE
	SYNTAX  DisplayString( SIZE(1..16))
	MAX-ACCESS read-write
	STATUS deprecated
	DESCRIPTION
        "
        Line Accepted DAPI :This register 
        defines the value of the accepted 
        Trace Identifier on the line input
        "
	::= { pme1008CfgLineDapiAccOtuEntry 3 }


--- *****************************************************
---     LEAF for the table Group startuptablefive
--- *****************************************************

pme1008CfgStartuptablefive OBJECT IDENTIFIER ::= { pme1008Config 18 }



--- *****************************************************
---     LEAF for the table 0005
--- *****************************************************

pme1008CfgOtxtlhcapabilitiesTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pme1008CfgOtxtlhcapabilitiesEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pme1008CfgStartuptablefive 1 }


pme1008CfgOtxtlhcapabilitiesEntry OBJECT-TYPE
	SYNTAX Pme1008CfgOtxtlhcapabilitiesEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the startuptablefive 
        table
        "
	INDEX   { pme1008CfgOtxtlhcapabilitiesIndex }
	::= { pme1008CfgOtxtlhcapabilitiesTable 1 }


Pme1008CfgOtxtlhcapabilitiesEntry ::=
	SEQUENCE {
	pme1008CfgOtxtlhcapabilitiesIndex
		INTEGER,
	pme1008CfgComponentTypePortn
		Unsigned32,
	pme1008CfgMiscellaneousPortn
		Unsigned32,
	pme1008CfgFirstChannelPortn
		Unsigned32,
	pme1008CfgLastChannelPortn
		Unsigned32,
	pme1008CfgGridPortn
		Unsigned32
	}


pme1008CfgOtxtlhcapabilitiesIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the otxtlhcapabilities 
        table
        "
	::= { pme1008CfgOtxtlhcapabilitiesEntry 1 }


pme1008CfgComponentTypePortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Component parameters :This OID 
        defines the component parameters
        "
	::= { pme1008CfgOtxtlhcapabilitiesEntry 3 }


pme1008CfgMiscellaneousPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Miscellaneous default settings 
        :This OID defines the miscellaneous 
        parameters
        "
	::= { pme1008CfgOtxtlhcapabilitiesEntry 4 }


pme1008CfgFirstChannelPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Number of the first channel of 
        the component :This OID defines 
        the first channel number of the 
        PM
        "
	::= { pme1008CfgOtxtlhcapabilitiesEntry 5 }


pme1008CfgLastChannelPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Number of the last channel of
         the component :This OID defines 
        the last channel number of the
         PM
        "
	::= { pme1008CfgOtxtlhcapabilitiesEntry 6 }


pme1008CfgGridPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Grid value of the component :This 
        OID defines the grid of the PM
        "
	::= { pme1008CfgOtxtlhcapabilitiesEntry 7 }



pme1008CfgWriteConfiguration  OBJECT-TYPE
	SYNTAX EkiOnOff
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
	"Write configuration to module:This OID 
	 writes the complete configuration to the module"
	::= { pme1008Config 257 }






--- *****************************************************
---     TRAP OBJECTS
--- *****************************************************

pme1008trapPortNumber OBJECT-TYPE
	SYNTAX INTEGER(1..64)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
	"Last port which generates a trap"
	::= { pme1008traps 2 }

pme1008trapLineNumber OBJECT-TYPE
	SYNTAX INTEGER(1..64)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
	"Last Line which generates a trap"
	::= { pme1008traps 3 }

pme1008trapBoardNumber OBJECT-TYPE
	SYNTAX INTEGER(1..64)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
	"Last module which generates a trap"
	::= { pme1008traps 4 }







--- *****************************************************
---     LINE TRAPS
--- *****************************************************

pme1008LineTrapNotUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pme1008AlmLineDdmWarningPortn, pme1008trapLineNumber, pme1008trapBoardNumber}
	STATUS current
	--&FILTNAME    "PME1008 Line Not Urgent ON"
	--&ACTIONS     { log, minor }
	--&MATCH       { pme1008AlmLineDdmWarningPortn "on", pme1008trapLineNumber "$2", pme1008trapBoardNumber "$3"}
	--&MESG        "DDM Warning appears on Line Port $2 of PME1008 in Slot $3 ($A)"
	DESCRIPTION "Not urgent Line default is activated"
	::= { pme1008traps 30 }

pme1008LineTrapNotUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pme1008AlmLineDdmWarningPortn, pme1008trapLineNumber, pme1008trapBoardNumber}
	STATUS current
	--&FILTNAME    "PME1008 Line Not Urgent OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      { "PME1008 Line Not Urgent ON" }
	--&MATCH       { pme1008AlmLineDdmWarningPortn "on", pme1008trapLineNumber "$2", pme1008trapBoardNumber "$3"}
	--&MESG        "DDM Warning disappears on Line Port $2 of PME1008 in Slot $3 ($A)"
	DESCRIPTION "Not urgent Line default disappeared"
	::= { pme1008traps 31 }

pme1008LineTrapUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pme1008AlmLineDdmAlmPortn, pme1008trapLineNumber, pme1008trapBoardNumber}
	STATUS current
	--&FILTNAME    "PME1008 Line Urgent ON"
	--&ACTIONS     { log, major }
	--&MATCH       { pme1008AlmLineDdmAlmPortn "on", pme1008trapLineNumber "$2", pme1008trapBoardNumber "$3"}
	--&MESG        "DDM Alarm appears on Line Port $2 of PME1008 in Slot $3 ($A)"
	DESCRIPTION "Urgent Line default is activated"
	::= { pme1008traps 32 }

pme1008LineTrapUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pme1008AlmLineDdmAlmPortn, pme1008trapLineNumber, pme1008trapBoardNumber}
	STATUS current
	--&FILTNAME    "PME1008 Line Urgent OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      { "PME1008 Line Urgent ON" }
	--&MATCH       { pme1008AlmLineDdmAlmPortn "on", pme1008trapLineNumber "$2", pme1008trapBoardNumber "$3"}
	--&MESG        "DDM Alarm disappears on Line Port $2 of PME1008 in Slot $3 ($A)"
	DESCRIPTION "Urgent Line default disappeared"
	::= { pme1008traps 33 }

pme1008LineTrapCritGoesOn NOTIFICATION-TYPE
	OBJECTS {pme1008AlmLineFailPortn , pme1008AlmLineHwFailPortn , pme1008trapLineNumber, pme1008trapBoardNumber}
	STATUS current
	--&FILTNAME    "PME1008 Line Fail ON"
	--&ACTIONS     { log, critical }
	--&MATCH       { pme1008AlmLineFailPortn "on", pme1008AlmLineHwFailPortn "*", pme1008trapLineNumber "$3", pme1008trapBoardNumber "$4"}
	--&MESG        "Line Port $3 Down on PME1008 in Slot $4 ($A)"
	
	--&FILTNAME    "PME1008 Line HW Fail ON (Hidden)"
	--&ACTIONS     { info }
	--&MATCH       { pme1008AlmLineFailPortn "*", pme1008AlmLineHwFailPortn "on", pme1008trapLineNumber "$3", pme1008trapBoardNumber "$4"}
	--&MESG        "Line Port $3 Down on PME1008 in Slot $4 ($A)"
	DESCRIPTION "Critical Line default is activated"
	::= { pme1008traps 34 }

pme1008LineTrapCritGoesOff NOTIFICATION-TYPE
	OBJECTS {pme1008AlmLineFailPortn , pme1008AlmLineHwFailPortn , pme1008trapLineNumber, pme1008trapBoardNumber}
	STATUS current
	--&FILTNAME    "PME1008 Line Fail OFF"
	--&ACTIONS     { log,  normal }
	--&CLEARS      { "PME1008 Line Fail ON" }
	--&MATCH       { pme1008AlmLineFailPortn "on", pme1008AlmLineHwFailPortn "*", pme1008trapLineNumber "$3", pme1008trapBoardNumber "$4"}
	--&MESG        "Line Port $3 Up on PME1008 in Slot $4 ($A)"

	--&FILTNAME    "PME1008 Line HW Fail OFF (Hidden)"
	--&ACTIONS     { info }
	--&MATCH       { pme1008AlmLineFailPortn "*", pme1008AlmLineHwFailPortn "on", pme1008trapLineNumber "$3", pme1008trapBoardNumber "$4"}
	--&MESG        "Line Port $3 Up on PME1008 in Slot $4 ($A)"
	DESCRIPTION "Critical Line default disappeared"
	::= { pme1008traps 35 }






--- *****************************************************
---     CLIENT TRAPS
--- *****************************************************

pme1008ClientTrapNotUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pme1008AlmSfpDdmWarningPortn, pme1008trapPortNumber, pme1008trapBoardNumber}
	STATUS current
		--&FILTNAME    "PME1008 Client Not Urgent ON"
		--&ACTIONS     { log, minor }
		--&MATCH       { pme1008AlmSfpDdmWarningPortn "on", pme1008trapPortNumber "$2", pme1008trapBoardNumber "$3"}
		--&MESG        "DDM Warning appears on Client Port $2 of PME1008 in Slot $3 ($A)"
	DESCRIPTION "Not urgent client default is activated"
	::= { pme1008traps 40 }

pme1008ClientTrapNotUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pme1008AlmSfpDdmWarningPortn, pme1008trapPortNumber, pme1008trapBoardNumber}
	STATUS current
		--&FILTNAME    "PME1008 Client Not Urgent OFF"
		--&ACTIONS     { log, normal }
		--&CLEARS      { "PME1008 Client Not Urgent ON" }
		--&MATCH       { pme1008AlmSfpDdmWarningPortn "on", pme1008trapPortNumber "$2", pme1008trapBoardNumber "$3"}
		--&MESG        "DDM Warning appears on Client Port $2 of PME1008 in Slot $3 ($A)"
	DESCRIPTION "Not urgent client default disappeared"
	::= { pme1008traps 41 }

pme1008ClientTrapUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pme1008AlmSfpDdmAlmPortn, pme1008trapPortNumber, pme1008trapBoardNumber}
	STATUS current
		--&FILTNAME    "PME1008 Client Urgent ON"
		--&ACTIONS     { log, major }
		--&MATCH       { pme1008AlmSfpDdmAlmPortn "on", pme1008trapPortNumber "$2", pme1008trapBoardNumber "$3"}
		--&MESG        "DDM Alarm appears on Client Port $2 of PME1008 in Slot $3 ($A)"
	DESCRIPTION "Urgent client default is activated"
	::= { pme1008traps 42 }

pme1008ClientTrapUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pme1008AlmSfpDdmAlmPortn, pme1008trapPortNumber, pme1008trapBoardNumber}
	STATUS current
		--&FILTNAME    "PME1008 Client Urgent OFF"
		--&ACTIONS     { log, normal }
		--&CLEARS      { "PME1008 Client Urgent ON" }
		--&MATCH       { pme1008AlmSfpDdmAlmPortn "on", pme1008trapPortNumber "$2", pme1008trapBoardNumber "$3"}
		--&MESG        "DDM Alarm disappears on Client Port $2 of PME1008 in Slot $3 ($A)"
	DESCRIPTION "Urgent client default disappeared"
	::= { pme1008traps 43 }

pme1008ClientTrapCritGoesOn NOTIFICATION-TYPE
	OBJECTS {pme1008AlmFailAccPortn, pme1008AlmHwFailAccPortn, pme1008trapPortNumber, pme1008trapBoardNumber}
	STATUS current
		--&FILTNAME    "PME1008 Client Fail ON"
		--&ACTIONS     { log, critical }
		--&MATCH       { pme1008AlmFailAccPortn "on", pme1008AlmHwFailAccPortn "*", pme1008trapPortNumber "$3", pme1008trapBoardNumber "$4"}
		--&MESG        "Client Port $3 Down on PME1008 in Slot $4 ($A)"
		
		--&FILTNAME    "PME1008 Client HW Fail ON (Hidden)"
		--&ACTIONS     { info }
		--&MATCH       { pme1008AlmFailAccPortn "*", pme1008AlmHwFailAccPortn "on", pme1008trapPortNumber "$3", pme1008trapBoardNumber "$4"}
		--&MESG        "Client Port $3 Down on PME1008 in Slot $4 ($A)"
	DESCRIPTION "Critical client default is activated"
	::= { pme1008traps 44 }

pme1008ClientTrapCritGoesOff NOTIFICATION-TYPE
	OBJECTS {pme1008AlmFailAccPortn, pme1008AlmHwFailAccPortn, pme1008trapPortNumber, pme1008trapBoardNumber}
	STATUS current
		--&FILTNAME    "PME1008 Client Fail OFF"
		--&ACTIONS     { log, normal }
		--&CLEARS      { "PME1008 Client Fail ON" }
		--&MATCH       { pme1008AlmFailAccPortn "on", pme1008AlmHwFailAccPortn "*", pme1008trapPortNumber "$3", pme1008trapBoardNumber "$4"}
		--&MESG        "Client Port $3 Up on PME1008 in Slot $4 ($A)"
		
		--&FILTNAME    "PME1008 Client HW Fail OFF (Hidden)"
		--&ACTIONS     { info }
		--&MATCH       { pme1008AlmFailAccPortn "*", pme1008AlmHwFailAccPortn "on", pme1008trapPortNumber "$3", pme1008trapBoardNumber "$4"}
		--&MESG        "Client Port $3 Up on PME1008 in Slot $4 ($A)"
	DESCRIPTION "Critical client default disappeared"
	::= { pme1008traps 45 }






--- *****************************************************
---     HW TRAPS
--- *****************************************************

pme1008PowerTrapUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pme1008AlmDefFuseB, pme1008AlmDefFuseA , pme1008trapBoardNumber}
	STATUS current
		--&FILTNAME    "PME1008 Fuse A Fail ON"
		--&ACTIONS     { log, major }
		--&MATCH       { pme1008AlmDefFuseB "*", pme1008AlmDefFuseA "on", pme1008trapBoardNumber "$3"}
		--&MESG        "Power Input A Fail on PME1008 in Slot $3 ($A)"
	
		--&FILTNAME    "PME1008 Fuse B Fail ON"
		--&ACTIONS     { log, major }
		--&MATCH       { pme1008AlmDefFuseB "on", pme1008AlmDefFuseA "*", pme1008trapBoardNumber "$3"}
		--&MESG        "Power Input B Fail on PME1008 in Slot $3 ($A)"
	DESCRIPTION "Urgent power supply default is activated"
	::= { pme1008traps 50 }

pme1008PowerTrapUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pme1008AlmDefFuseB, pme1008AlmDefFuseA , pme1008trapBoardNumber}
	STATUS current
		--&FILTNAME    "PME1008 Fuse A&B Fail OFF"
		--&ACTIONS     { log, normal}
		--&CLEARS      { "PME1008 Fuse A Fail ON", "PME1008 Fuse B Fail ON" }
		--&MATCH       { pme1008AlmDefFuseB "on", pme1008AlmDefFuseA "on", pme1008trapBoardNumber "$3"}
		--&MESG        "Power Inputs A and B Present on PME1008 in Slot $3 ($A)"
	DESCRIPTION "Urgent power supply default disappeared"
	::= { pme1008traps 51 }






END