-- EKINOPS-Pmapc.TXT:  MIB
--
--MIB Part Number:3MI00206AEAD
--MIB Version:01
--
-- Copyright (c) 2016 by Ekinops
-- All rights reserved.
-- 
-- *****************************************************************

EKINOPS-Pmapc-MIB DEFINITIONS ::= BEGIN

IMPORTS
	ekinops,
	EkiState,
	EkiOnOff,
	EkiMode,
	EkiProtocol,
	EkiApiState,
	EkiSynchroMode,
	EkiMeasureType
			FROM EKINOPS-MIB
        MODULE-IDENTITY,
        OBJECT-TYPE,
        NOTIFICATION-TYPE,
	Unsigned32,
	Integer32,
	Counter32,
	IpAddress                
        		FROM SNMPv2-SMI
 	TEXTUAL-CONVENTION,
	DisplayString
                FROM SNMPv2-TC;

modulePmapc MODULE-IDENTITY
        LAST-UPDATED "201605230000Z"
        ORGANIZATION "Ekinops"
        CONTACT-INFO
         "Ekinops

          3, rue Blaise Pascal
          F-22300 Lannion / FRANCE

          Tel : +33 (0)2 96 05 00 30
          Fax : +33 (0)2 96 48 62 39

          E-mail: support@ekinops.net"
        DESCRIPTION
          "MIB for the Ekinops Pmapc hardware."
	REVISION "200905290000Z"
	DESCRIPTION
	  "Initial Version."
	REVISION "200909290000Z"
	DESCRIPTION
	  "CondTypeParameters insertion"
	REVISION "201002250000Z"
	DESCRIPTION
	  "Probcause,AlarmType - NMS"
	REVISION "201011050000Z"
	DESCRIPTION
	  "Formulas in comments"
	REVISION "201012140000Z"
	DESCRIPTION
	  "Add Inventory of the lasers"
	REVISION "201207040000Z"
	DESCRIPTION
	  "Minor cosmetic updates"
	REVISION "201403250000Z"
	DESCRIPTION
	  "Probcause,AlarmType - NMS completion"
	REVISION "201411210000Z"
	DESCRIPTION
	  "Labels cosmetic updates"
	REVISION "201605230000Z"
	DESCRIPTION
	  "New AlarmType  synthesisAlarm (12)"
        ::= { ekinops 42 }



--- *****************************************************
---     LEAF LEVEL 2
--- *****************************************************


pmapcalarms OBJECT IDENTIFIER ::= { modulePmapc 2 }	
pmapcAlmOther OBJECT IDENTIFIER ::= { pmapcalarms 1 }
pmapcAlmOtherNurg OBJECT IDENTIFIER ::= { pmapcAlmOther 1 }
pmapcAlmOtherUrg OBJECT IDENTIFIER ::= { pmapcAlmOther 2 }
pmapcAlmOtherCrit OBJECT IDENTIFIER ::= { pmapcAlmOther 3 }

pmapcAlmClient OBJECT IDENTIFIER ::= { pmapcalarms 2 }
pmapcAlmClientNurg OBJECT IDENTIFIER ::= { pmapcAlmClient 1 }
pmapcAlmClientUrg OBJECT IDENTIFIER ::= { pmapcAlmClient 2 }
pmapcAlmClientCrit OBJECT IDENTIFIER ::= { pmapcAlmClient 3 }
	
pmapcAlmLine OBJECT IDENTIFIER ::= { pmapcalarms 3 }
pmapcAlmLineNurg OBJECT IDENTIFIER ::= { pmapcAlmLine 1 }
pmapcAlmLineUrg OBJECT IDENTIFIER ::= { pmapcAlmLine 2 }
pmapcAlmLineCrit OBJECT IDENTIFIER ::= { pmapcAlmLine 3 }


pmapcmeasures OBJECT IDENTIFIER ::= { modulePmapc 3 }	
pmapcMesrOther OBJECT IDENTIFIER ::= { pmapcmeasures 1 }	
pmapcMesrClient OBJECT IDENTIFIER ::= { pmapcmeasures 2 }	
pmapcMesrLine OBJECT IDENTIFIER ::= { pmapcmeasures 3 }	


pmapccontrolsWrite OBJECT IDENTIFIER ::= { modulePmapc 6 }
pmapcCtrlOther OBJECT IDENTIFIER ::= { pmapccontrolsWrite 1 }
pmapcCtrlClient OBJECT IDENTIFIER ::= { pmapccontrolsWrite 2 }
pmapcCtrlLine OBJECT IDENTIFIER ::= { pmapccontrolsWrite 3 }

pmapcri OBJECT IDENTIFIER ::= { modulePmapc 7 }
pmapcriTable OBJECT IDENTIFIER ::= { pmapcri 1 }


pmapcConfig OBJECT IDENTIFIER ::= { modulePmapc 9 }

pmapctraps OBJECT IDENTIFIER ::= { modulePmapc 10 }

--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     TEXTUAL-CONVENTION
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     REMOTE INVENTORY
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************

pmapcRinvReloadInventory OBJECT-TYPE
  SYNTAX EkiOnOff
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
        "Reload the inventory: This OID triggers an 
         inventory reload."
  ::= { pmapcri 2 }

pmapcRinvHwPlatform OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
        "HW platform description: This OID contains the 
         description of the Hardware platform."
  ::= { pmapcri 3 }
  
pmapcRinvModulePlatform OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
        "Module platform description: This OID contains the 
         description of the Module."
  ::= { pmapcri 4 }
  
pmapcRinvSwPlatform OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
        "SW platform description: This OID contains the 
         description of the Software platform."
  ::= { pmapcri 5 }



pmapcRinvLaser1Table OBJECT-TYPE
      SYNTAX  SEQUENCE OF PmapcRinvLaser1Entry
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
              "List of the laser clients on the selected module"
      ::= { pmapcriTable 1 }

pmapcRinvLaser1Entry OBJECT-TYPE
        SYNTAX  PmapcRinvLaser1Entry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
              "Row definition for the laser client table"
        INDEX   { pmapcRinvLaser1Index }
        ::= { pmapcRinvLaser1Table 1 }
    


PmapcRinvLaser1Entry::=
        SEQUENCE {
          pmapcRinvLaser1Index 
              Integer32,
          pmapcRinvLaser1
              DisplayString
        }


    pmapcRinvLaser1Index OBJECT-TYPE
        SYNTAX  Integer32(1..16)
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
              "Index for laser client table"
        ::= { pmapcRinvLaser1Entry 1 }


    pmapcRinvLaser1 OBJECT-TYPE
        SYNTAX  DisplayString
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
              "Inventory for the laser client: This OID contains the inventory for the laser client"
        ::= { pmapcRinvLaser1Entry 2 }



pmapcRinvLaser2Table OBJECT-TYPE
      SYNTAX  SEQUENCE OF PmapcRinvLaser2Entry
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
              "List of the laser clients on the selected module"
      ::= { pmapcriTable 2 }

pmapcRinvLaser2Entry OBJECT-TYPE
        SYNTAX  PmapcRinvLaser2Entry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
              "Row definition for the laser client table"
        INDEX   { pmapcRinvLaser2Index }
        ::= { pmapcRinvLaser2Table 1 }
    


PmapcRinvLaser2Entry::=
        SEQUENCE {
          pmapcRinvLaser2Index 
              Integer32,
          pmapcRinvLaser2
              DisplayString
        }


    pmapcRinvLaser2Index OBJECT-TYPE
        SYNTAX  Integer32(1..16)
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
              "Index for laser client table"
        ::= { pmapcRinvLaser2Entry 1 }


    pmapcRinvLaser2 OBJECT-TYPE
        SYNTAX  DisplayString
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
              "Inventory for the laser client: This OID contains the inventory for the laser client"
        ::= { pmapcRinvLaser2Entry 2 }









--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     ALARMS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the synthAlm0 article
--- *****************************************************
pmapcAlmsynthAlm0 OBJECT IDENTIFIER ::= { pmapcAlmOtherCrit 0 }




pmapcAlmDefFuseB OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Fuse B Fail :This OID indicates 
        that the fuse of the power input 
        B is in fail condition   <Help> 
          Status of the Fuse B <Condtype> 
        DEF_FUSE_B <Probcause> powerProblem 
        (36) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmsynthAlm0 16 }



pmapcAlmDefFuseA OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Fuse A Fail :This OID indicates 
        that the fuse of the power input 
        A is in fail condition   <Help> 
          Status of the Fuse A <Condtype> 
        DEF_FUSE_A <Probcause> powerProblem 
        (36) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmsynthAlm0 15 }



pmapcAlmModuleGlobFailure OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Module Failure :This OID is set 
        on detection of a failure originating 
        from the PM <Condtype> MODULE_GLOB_FAILURE 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	  ::= { pmapcAlmsynthAlm0 9 }



pmapcAlmPwrOutWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Power Output Warning :This OID 
        indicates that  the power output 
        on the transmit side is in warning 
        condition   <Help>   This warning 
        indicates that the power output 
        is in a warning out of range <Condtype> 
        PWR_OUT_WNG <Probcause> powerProblem 
        (36) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmsynthAlm0 8 }



pmapcAlmPwrOutAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Power Output Alarm :This OID indicates 
        that  the power output on the transmit 
        side is in fail condition  <Help> 
          This alarm indicates that the 
        power output is in an alarm out 
        of range <Condtype> PWR_OUT_ALA 
        <Probcause> powerProblem (36) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmsynthAlm0 7 }



pmapcAlmPwrInWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Power Input Warning :This OID
         indicates that  the power input 
        on the transmit side is in warning 
        condition  <Help>   This warning 
        indicates that the power input
         is in a warning out of range <Condtype> 
        PWR_IN_WNG <Probcause> powerProblem 
        (36) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmsynthAlm0 6 }



pmapcAlmPwrInAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Power Input Alarm :This OID indicates 
        that  the power input on the transmit 
        side is in fail condition  <Help> 
          This alarm indicates that the 
        power input is in an alarm out
         of range <Condtype> PWR_IN_ALA 
        <Probcause> powerProblem (36) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmsynthAlm0 5 }



--- *****************************************************
---     LEAF for the synthAlm2 article
--- *****************************************************
pmapcAlmsynthAlm2 OBJECT IDENTIFIER ::= { pmapcAlmOtherNurg 2 }




pmapcAlmCorrelatOff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Not Used :This OID, when set,
         indicates that alarm correlation 
        is not being performed. <Condtype> 
        CORRELAT_OFF <Probcause> other
         (1) <Alarmtype> other (1) <Polarity> 
        (2) 
        "
	  ::= { pmapcAlmsynthAlm2 4 }



pmapcAlmConfTableLoad OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        PM Configuration Load :This OID 
         is at 1 during the loading of
         configuration tables in the modules 
        RAM. <Condtype> CONF_TABLE_LOAD 
        <Probcause> other (1) <Alarmtype> 
        other (1) <Polarity> (2) 
        "
	  ::= { pmapcAlmsynthAlm2 3 }



pmapcAlmInvUpload OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Inventory Upload :This OID is
         at 1 during the uploading of PM 
        inventory information. <Condtype> 
        INV_UPLOAD <Probcause> other (1) 
        <Alarmtype> other (1) <Polarity> 
        (2) 
        "
	  ::= { pmapcAlmsynthAlm2 2 }



pmapcAlmConfTableSave OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        PM Configuration Save :This OID 
        is at 1 during the saving of a
         new configuration table in the 
        module Flash memory. <Condtype> 
        CONF_TABLE_SAVE <Probcause> other 
        (1) <Alarmtype> other (1) <Polarity> 
        (2) 
        "
	  ::= { pmapcAlmsynthAlm2 1 }



--- *****************************************************
---     LEAF for the synthAlmLaser1 article
--- *****************************************************
pmapcAlmsynthAlmLaser1 OBJECT IDENTIFIER ::= { pmapcAlmClientCrit 8 }




pmapcAlmLas1FailAcc OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Stuff. Wavelength 1 Fail :This 
        OID indicates a failure on the
         Stuffing Wavelength Laser 1 <Condtype> 
        LAS1_FAIL_ACC <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	  ::= { pmapcAlmsynthAlmLaser1 12 }



pmapcAlmLas1MeasAlm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Stuff. Wavelength 1 Alarm :This 
        OID indicates if an alarm is present 
        coming out of Stuffing Wavelength 
        Laser 1 monitoring   <Help>   This 
        alarm indicates if a monitoring 
        alarm has been detected on the
         Laser 1 <Condtype> LAS1_MEAS_ALM 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	  ::= { pmapcAlmsynthAlmLaser1 10 }



pmapcAlmLas1MeasWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Stuff. Wavelength 1 Warning :This 
        OID indicates a warning is present 
        coming out of Stuffing Wavelength 
        Laser 1 monitoring  <Help>   This 
        alarm indicates if a monitoring 
        warning has been detected on the 
        Laser 1 <Condtype> LAS1_MEAS_WNG 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	  ::= { pmapcAlmsynthAlmLaser1 9 }



pmapcAlmLas1LocalOos OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Stuff. Wavelength 1 Out Of Service 
        :This OID indicates that the Stuffing 
        Wavelength Laser 1 is In Service 
        (1) of Out or Service (2).  <Help> 
          This status indicates if the
         Laser 1 is in service <Condtype> 
        LAS1_LOCAL_OOS <Probcause> informationalStatus(1000) 
        <Alarmtype> other (1) <Polarity> 
        (2) 
        "
	  ::= { pmapcAlmsynthAlmLaser1 6 }



pmapcAlmLas1HwFailAcc OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Stuff. Wavelength 1 HW Fail :This 
        OID indicates a hardware failure 
        on the Stuffing Wavelength Laser 
        1 <Condtype> LAS1_HW_FAIL_ACC <Probcause> 
        equipmentMalfunction (16) <Alarmtype> 
        synthesisAlarm (12)  <Polarity> 
        (2) 
        "
	  ::= { pmapcAlmsynthAlmLaser1 4 }



pmapcAlmLas1InitNotCompl OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Stuff. Wavelength 1 Not Ready
         :This OID indicates that the optical 
        interface  of the Stuffing Wavelength 
        Laser 1 is not operational.   <Help> 
          This status indicates if Laser 
        1 has been correctly initialized 
        <Condtype> LAS1_INIT_NOT_COMPL
         <Probcause> equipmentMalfunction 
        (16) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmsynthAlmLaser1 2 }



--- *****************************************************
---     LEAF for the synthAlmLaser2 article
--- *****************************************************
pmapcAlmsynthAlmLaser2 OBJECT IDENTIFIER ::= { pmapcAlmClientCrit 9 }




pmapcAlmLas2FailAcc OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Stuff. Wavelength 2 Fail :This 
        OID indicates a failure on the
         Stuffing Wavelength Laser 2 <Condtype> 
        LAS2_FAIL_ACC <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	  ::= { pmapcAlmsynthAlmLaser2 12 }



pmapcAlmLas2MeasAlm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Stuff. Wavelength 2 Alarm :This 
        OID indicates if an alarm is present 
        coming out of Stuffing Wavelength 
        Laser 2 monitoring   <Help>   This 
        alarm indicates if a monitoring 
        alarm has been detected on the
         Laser 2 <Condtype> LAS2_MEAS_ALM 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	  ::= { pmapcAlmsynthAlmLaser2 10 }



pmapcAlmLas2MeasWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Stuff. Wavelength 2 Warning :This 
        OID indicates a warning is present 
        coming out of Stuffing Wavelength 
        Laser 2 monitoring  <Help>   This 
        alarm indicates if a monitoring 
        warning has been detected on the 
        Laser 2 <Condtype> LAS2_MEAS_WNG 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	  ::= { pmapcAlmsynthAlmLaser2 9 }



pmapcAlmLas2LocalOos OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Stuff. Wavelength 2 Out Of Service 
        :This OID indicates that the Stuffing 
        Wavelength Laser 2 is In Service 
        (2) of Out or Service (2).  <Help> 
          This status indicates if the
         Laser 2 is in service <Condtype> 
        LAS2_LOCAL_OOS <Probcause> informationalStatus(1000) 
        <Alarmtype> other (1) <Polarity> 
        (2) 
        "
	  ::= { pmapcAlmsynthAlmLaser2 6 }



pmapcAlmLas2HwFailAcc OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Stuff. Wavelength 2 HW Fail :This 
        OID indicates a hardware failure 
        on the Stuffing Wavelength Laser 
        2 <Condtype> LAS2_HW_FAIL_ACC <Probcause> 
        equipmentMalfunction (16) <Alarmtype> 
        synthesisAlarm (12)  <Polarity> 
        (2) 
        "
	  ::= { pmapcAlmsynthAlmLaser2 4 }



pmapcAlmLas2InitNotCompl OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Stuff. Wavelength 2 Not Ready
         :This OID indicates that the optical 
        interface  of the Stuffing Wavelength 
        Laser 2 is not operational.   <Help> 
          This status indicates if Laser 
        2 has been correctly initialized 
        <Condtype> LAS2_INIT_NOT_COMPL
         <Probcause> equipmentMalfunction 
        (16) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmsynthAlmLaser2 2 }



--- *****************************************************
---     LEAF for the laser1Alm article
--- *****************************************************
pmapcAlmlaser1Alm OBJECT IDENTIFIER ::= { pmapcAlmClientUrg 16 }




pmapcAlmLas1Tec1Fail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Stuff. Wavelength 1 TEC Fail :This 
        OID indicates that the TEC of the 
        Stuffing Wavelength Laser 1 failed 
        on the transmit side.  <Help> 
          This alarm indicates if the TEC 
        of the Laser 1 of the transmit
         line is in a fail condition  <Condtype> 
        LAS1_TEC1_FAIL <Probcause> pumpFailure 
        (39) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser1Alm 2 }



pmapcAlmLas1Fail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Stuff. Wavelength 1 Fail :This 
        OID indicates that the Stuffing 
        Wavelength Laser 1 failed on the 
        transmit side  <Help>   This alarm 
        indicates if the laser of the transmit 
         line is in a fail condition  <Condtype> 
        LAS1_FAIL <Probcause> pumpFailure 
        (39) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser1Alm 1 }



--- *****************************************************
---     LEAF for the laser1MeasAlm article
--- *****************************************************
pmapcAlmlaser1MeasAlm OBJECT IDENTIFIER ::= { pmapcAlmClientUrg 17 }




pmapcAlmILas1HighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 1 Current High Alarm :This 
        OID indicates that the current
         of the Stuffing Wavelength Laser 
        1 is higher than the alarm threshold 
         <Help>   This alarm indicates
         if the current of the Laser 1
         is too high <Condtype> I_LAS1_HIGH_ALA 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser1MeasAlm 8 }



pmapcAlmILas1LowAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 1 Current Low Alarm :This 
        OID indicates that the current
         of the Stuffing Wavelength Laser 
        1 is lower than the alarm threshold 
         <Help>   This alarm indicates
         if the current of the Laser 1
         is too low <Condtype> I_LAS1_LOW_ALA 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser1MeasAlm 7 }



pmapcAlmVtecLas1HighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 1 TEC Volt High Alarm :This 
        OID indicates that the TEC voltage 
        of the Stuffing Wavelength Laser 
        1 is higher than the alarm threshold 
         <Help>   This alarm indicates
         if the TEC voltage of the Laser 
        1 is too high <Condtype> VTEC_LAS1_HIGH_ALA 
        <Probcause> powerProblem (36) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser1MeasAlm 6 }



pmapcAlmVtecLas1LowAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 1 TEC Volt Low Alarm :This 
        OID indicates that the TEC voltage 
        of the Stuffing Wavelength Laser 
        1 is lower than the alarm threshold 
         <Help>   This alarm indicates
         if the TEC voltage of the Laser 
        1 is too low <Condtype> VTEC_LAS1_LOW_ALA 
        <Probcause> powerProblem (36) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser1MeasAlm 5 }



pmapcAlmVthLas1HighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 1 TEC Temp High Alarm :This 
        OID indicates that the TEC temperature 
        of the Stuffing Wavelength Laser 
        1 is higher than the alarm threshold 
         <Help>   This alarm indicates
         if the TEC temperature of the
         Laser 1 is too high <Condtype> 
        VTH_LAS1_HIGH_ALA <Probcause> pumpFailure 
        (39) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser1MeasAlm 4 }



pmapcAlmVthLas1LowAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 1 TEC Temp Low Alarm :This 
        OID indicates that the TEC temperature 
        of the Stuffing Wavelength Laser 
        1 is lower than the alarm threshold 
         <Help>   This alarm indicates
         if the TEC temperature of the
         Laser 1 is too low <Condtype>
         VTH_LAS1_LOW_ALA <Probcause> pumpFailure 
        (39) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser1MeasAlm 3 }



pmapcAlmPwrLas1HighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 1 Pwr High Alarm :This OID 
        indicates that transmit power of 
        the Stuffing Wavelength Laser 1 
        is higher than the alarm threshold 
         <Help>   This alarm indicates
         if the transmit power on the transmit 
        side of the Laser 1 is too high 
        <Condtype> PWR_LAS1_HIGH_ALA <Probcause> 
        pumpFailure (39) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser1MeasAlm 2 }



pmapcAlmPwrLas1LowAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 1 Pwr Low Alarm :This OID 
        indicates that transmit power of 
        the Stuffing Wavelength Laser 1 
        is lower than the alarm threshold 
         <Help>   This alarm indicates
         if the transmit power on the transmit 
        side of the Laser 1 is too low
         <Condtype> PWR_LAS1_LOW_ALA <Probcause> 
        pumpFailure (39) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser1MeasAlm 1 }



--- *****************************************************
---     LEAF for the laser1MeasWng article
--- *****************************************************
pmapcAlmlaser1MeasWng OBJECT IDENTIFIER ::= { pmapcAlmClientNurg 18 }




pmapcAlmILas1HighWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 1 Current High Warning :This 
        OID indicates that the current
         of the Stuffing Wavelength Laser 
        1 is higher than the warning threshold 
         <Help>   This warning indicates 
        if the current of the Laser 1 is 
        too high <Condtype> I_LAS1_HIGH_WNG 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser1MeasWng 8 }



pmapcAlmILas1LowWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 1 Current Low Warning :This 
        OID indicates that the current
         of the Stuffing Wavelength Laser 
        1 is lower than the warning threshold 
         <Help>   This warning indicates 
        if the current of the Laser 1 is 
        too low <Condtype> I_LAS1_LOW_WNG 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser1MeasWng 7 }



pmapcAlmVtecLas1HighWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 1 TEC Volt High Warning
         :This OID indicates that the TEC 
        voltage of the Stuffing Wavelength 
        Laser 1 is higher than the warning 
        threshold  <Help>   This warning 
        indicates if the TEC voltage of 
        the Laser 1 is too high <Condtype> 
        VTEC_LAS1_HIGH_WNG <Probcause>
         powerProblem (36) <Alarmtype>
         equipmentAlarm (5) <Polarity>
         (2) 
        "
	  ::= { pmapcAlmlaser1MeasWng 6 }



pmapcAlmVtecLas1LowWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 1 TEC Volt Low Warning :This 
        OID indicates that the TEC voltage 
        of the Stuffing Wavelength Laser 
        1 is lower than the warning threshold 
         <Help>   This warning indicates 
        if the TEC voltage of the Laser 
        1 is too low <Condtype> VTEC_LAS1_LOW_WNG 
        <Probcause> powerProblem (36) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser1MeasWng 5 }



pmapcAlmVthLas1HighWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 1 TEC Temp High Warning
         :This OID indicates that the TEC 
        temperature of the Stuffing Wavelength 
        Laser 1 is higher than the warning 
        threshold  <Help>   This warning 
        indicates if the TEC temperature 
        of the Laser 1 is too high <Condtype> 
        VTH_LAS1_HIGH_WNG <Probcause> pumpFailure 
        (39) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser1MeasWng 4 }



pmapcAlmVthLas1LowWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 1 TEC Temp Low Warning :This 
        OID indicates that the TEC temperature 
        of the Stuffing Wavelength Laser 
        1 is lower than the warning threshold 
         <Help>   This warning indicates 
        if the TEC temperature of the Laser 
        1 is too low <Condtype> VTH_LAS1_LOW_WNG 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser1MeasWng 3 }



pmapcAlmPwrLas1HighWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 1 Pwr High Warning :This 
        OID indicates that transmit power 
        of the Stuffing Wavelength Laser 
        1 is higher than the warning threshold 
         <Help>   This warning indicates 
        if the transmit power on the transmit 
        side of the Laser 1 is too high 
        <Condtype> PWR_LAS1_HIGH_WNG <Probcause> 
        pumpFailure (39) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser1MeasWng 2 }



pmapcAlmPwrLas1LowWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 1 Pwr Low Warning :This
         OID indicates that transmit power 
        of the Stuffing Wavelength Laser 
        1 is lower than the warning threshold 
         <Help>   This warning indicates 
        if the transmit power on the transmit 
        side of the Laser 1 is too low
         <Condtype> PWR_LAS1_LOW_WNG <Probcause> 
        pumpFailure (39) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser1MeasWng 1 }



--- *****************************************************
---     LEAF for the laser2Alm article
--- *****************************************************
pmapcAlmlaser2Alm OBJECT IDENTIFIER ::= { pmapcAlmLineUrg 24 }




pmapcAlmLas2TecFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Stuff. Wavelength 2 TEC Fail :This 
        OID indicates that the TEC of the 
        Stuffing Wavelength Laser 2 failed 
        on the transmit side.  <Help> 
          This alarm indicates if the TEC 
        of the Laser 2 of the transmit
         line is in a fail condition  <Condtype> 
        LAS2_TEC_FAIL <Probcause> pumpFailure 
        (39) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser2Alm 2 }



pmapcAlmLas2Fail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Stuff. Wavelength 2 Fail :This 
        OID indicates that the Stuffing 
        Wavelength Laser 2 failed on the 
        transmit side  <Help>   This alarm 
        indicates if the laser of the transmit 
         line is in a fail condition  <Condtype> 
        LAS2_FAIL <Probcause> pumpFailure 
        (39) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser2Alm 1 }



--- *****************************************************
---     LEAF for the laser2MeasAla article
--- *****************************************************
pmapcAlmlaser2MeasAla OBJECT IDENTIFIER ::= { pmapcAlmLineUrg 25 }




pmapcAlmILas2HighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 2 Current High Alarm :This 
        OID indicates that the current
         of the Stuffing Wavelength Laser 
        2 is higher than the alarm threshold 
         <Help>   This alarm indicates
         if the current of the Laser 2
         is too high <Condtype> I_LAS2_HIGH_ALA 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser2MeasAla 8 }



pmapcAlmILas2LowAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 2 Current Low Alarm :This 
        OID indicates that the current
         of the Stuffing Wavelength Laser 
        2 is lower than the alarm threshold 
         <Help>   This alarm indicates
         if the current of the Laser 2
         is too low <Condtype> I_LAS2_LOW_ALA 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser2MeasAla 7 }



pmapcAlmVtecLas2HighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 2 TEC Volt High Alarm :This 
        OID indicates that the TEC voltage 
        of the Stuffing Wavelength Laser 
        2 is higher than the alarm threshold 
         <Help>   This alarm indicates
         if the TEC voltage of the Laser 
        2 is too high <Condtype> VTEC_LAS2_HIGH_ALA 
        <Probcause> powerProblem (36) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser2MeasAla 6 }



pmapcAlmVtecLas2LowAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 2 TEC Volt Low Alarm :This 
        OID indicates that the TEC voltage 
        of the Stuffing Wavelength Laser 
        2 is lower than the alarm threshold 
         <Help>   This alarm indicates
         if the TEC voltage of the Laser 
        2 is too low <Condtype> VTEC_LAS2_LOW_ALA 
        <Probcause> powerProblem (36) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser2MeasAla 5 }



pmapcAlmVthLas2HighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 2 TEC Temp High Alarm :This 
        OID indicates that the TEC temperature 
        of the Stuffing Wavelength Laser 
        2 is higher than the alarm threshold 
         <Help>   This alarm indicates
         if the TEC temperature of the
         Laser 2 is too high <Condtype> 
        VTH_LAS2_HIGH_ALA <Probcause> pumpFailure 
        (39) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser2MeasAla 4 }



pmapcAlmVthLas2LowAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 2 TEC Temp Low Alarm :This 
        OID indicates that the TEC temperature 
        of the Stuffing Wavelength Laser 
        2 is lower than the alarm threshold 
         <Help>   This alarm indicates
         if the TEC temperature of the
         Laser 2 is too low <Condtype>
         VTH_LAS2_LOW_ALA <Probcause> pumpFailure 
        (39) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser2MeasAla 3 }



pmapcAlmPwrLas2HighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 2 Pwr High Alarm :This OID 
        indicates that transmit power of 
        the Stuffing Wavelength Laser 2 
        is higher than the alarm threshold 
         <Help>   This alarm indicates
         if the transmit power on the transmit 
        side of the Laser 2 is too high 
        <Condtype> PWR_LAS2_HIGH_ALA <Probcause> 
        pumpFailure (39) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser2MeasAla 2 }



pmapcAlmPwrLas2LowAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 2 Pwr Low Alarm :This OID 
        indicates that transmit power of 
        the Stuffing Wavelength Laser 2 
        is lower than the alarm threshold 
         <Help>   This alarm indicates
         if the transmit power on the transmit 
        side of the Laser 2 is too low
         <Condtype> PWR_LAS2_LOW_ALA <Probcause> 
        pumpFailure (39) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser2MeasAla 1 }



--- *****************************************************
---     LEAF for the laser2MeasWng article
--- *****************************************************
pmapcAlmlaser2MeasWng OBJECT IDENTIFIER ::= { pmapcAlmLineNurg 26 }




pmapcAlmILas2HighWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 2 Current High Warning :This 
        OID indicates that the current
         of the Stuffing Wavelength Laser 
        2 is higher than the warning threshold 
         <Help>   This warning indicates 
        if the current of the Laser 2 is 
        too high <Condtype> I_LAS2_HIGH_WNG 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser2MeasWng 8 }



pmapcAlmILas2LowWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 2 Current Low Warning :This 
        OID indicates that the current
         of the Stuffing Wavelength Laser 
        2 is lower than the warning threshold 
         <Help>   This warning indicates 
        if the current of the Laser 2 is 
        too low <Condtype> I_LAS2_LOW_WNG 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser2MeasWng 7 }



pmapcAlmVtecLas2HighWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 2 TEC Volt High Warning
         :This OID indicates that the TEC 
        voltage of the Stuffing Wavelength 
        Laser 2 is higher than the warning 
        threshold  <Help>   This warning 
        indicates if the TEC voltage of 
        the Laser 2 is too high <Condtype> 
        VTEC_LAS2_HIGH_WNG <Probcause>
         powerProblem (36) <Alarmtype>
         equipmentAlarm (5) <Polarity>
         (2) 
        "
	  ::= { pmapcAlmlaser2MeasWng 6 }



pmapcAlmVtecLas2LowWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 2 TEC Volt Low Warning :This 
        OID indicates that the TEC voltage 
        of the Stuffing Wavelength Laser 
        2 is lower than the warning threshold 
         <Help>   This warning indicates 
        if the TEC voltage of the Laser 
        2 is too low <Condtype> VTEC_LAS2_LOW_WNG 
        <Probcause> powerProblem (36) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser2MeasWng 5 }



pmapcAlmVthLas2HighWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 2 TEC Temp High Warning
         :This OID indicates that the TEC 
        temperature of the Stuffing Wavelength 
        Laser 2 is higher than the warning 
        threshold  <Help>   This warning 
        indicates if the TEC temperature 
        of the Laser 2 is too high <Condtype> 
        VTH_LAS2_HIGH_WNG <Probcause> pumpFailure 
        (39) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser2MeasWng 4 }



pmapcAlmVthLas2LowWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 2 TEC Temp Low Warning :This 
        OID indicates that the TEC temperature 
        of the Stuffing Wavelength Laser 
        2 is lower than the warning threshold 
         <Help>   This warning indicates 
        if the TEC temperature of the Laser 
        2 is too low <Condtype> VTH_LAS2_LOW_WNG 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser2MeasWng 3 }



pmapcAlmPwrLas2HighWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 2 Pwr High Warning :This 
        OID indicates that transmit power 
        of the Stuffing Wavelength Laser 
        2 is higher than the warning threshold 
         <Help>   This warning indicates 
        if the transmit power on the transmit 
        side of the Laser 2 is too high 
        <Condtype> PWR_LAS2_HIGH_WNG <Probcause> 
        pumpFailure (39) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser2MeasWng 2 }



pmapcAlmPwrLas2LowWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Laser 2 Pwr Low Warning :This
         OID indicates that transmit power 
        of the Stuffing Wavelength Laser 
        2 is lower than the warning threshold 
         <Help>   This warning indicates 
        if the transmit power on the transmit 
        side of the Laser 2 is too low
         <Condtype> PWR_LAS2_LOW_WNG <Probcause> 
        pumpFailure (39) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmlaser2MeasWng 1 }



--- *****************************************************
---     LEAF for the moduleAlarm article
--- *****************************************************
pmapcAlmmoduleAlarm OBJECT IDENTIFIER ::= { pmapcAlmOtherUrg 64 }




pmapcAlmLossInputSignal OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Loss Of Input Signal :This OID 
        indicates there is a Loss of Signal 
        on the input of the module.   <Help> 
          This alarm indicates if there 
        is a Loss of Signal of the input 
        of the module. <Condtype> LOSS_INPUT_SIGNAL 
        <Probcause> receiveFailure (41) 
        <Alarmtype> physicalViolation (9) 
        <Polarity> (2) 
        "
	  ::= { pmapcAlmmoduleAlarm 16 }



pmapcAlmEamAttHighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        EAM Attenuation High Alarm :This 
        OID indicates that the attenuation 
        of the EAM is higher than the alarm 
        threshold  <Help>   This alarm
         indicates if the attenuation of 
        the EAM is too high <Condtype>
         EAM_ATT_HIGH_ALA <Probcause> equipmentMalfunction 
        (16) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmmoduleAlarm 6 }



pmapcAlmEamAttLowAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        EAM Attenuation Low Alarm :This 
        OID indicates that the attenuation 
        of the EAM is lower than the alarm 
        threshold  <Help>   This alarm
         indicates if the attenuation of 
        the EAM is too low <Condtype> EAM_ATT_LOW_ALA 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmmoduleAlarm 5 }



pmapcAlmPwrOutHighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Power Output High Alarm :This
         OID indicates that Output power 
        of the transmit side is higher
         than the alarm threshold  <Help> 
          This alarm indicates if the transmit 
        power on the transmit side  is
         too high <Condtype> PWR_OUT_HIGH_ALA 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmmoduleAlarm 4 }



pmapcAlmPwrOutLowAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Power Output Low Alarm :This OID 
        indicates that Output power of
         the transmit side is lower than 
        the alarm threshold   <Help>  
         This alarm indicates if the transmit 
        power on the transmit side  is
         too low <Condtype> PWR_OUT_LOW_ALA 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmmoduleAlarm 3 }



pmapcAlmPwrInHighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Power Input High Alarm :This OID 
        indicates that input power of the 
        transmit side is higher than the 
        alarm threshold  <Help>   This
         alarm indicates if the received 
        power on the transmit side  is
         too high <Condtype> PWR_IN_HIGH_ALA 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmapcAlmmoduleAlarm 2 }



pmapcAlmPwrInLowAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Power Input Low Alarm :This OID 
        indicates that input power of the 
        transmit side is lower than the 
        alarm threshold   <Help>   This 
        alarm indicates if the received 
        power on the transmit side  is
         too low <Condtype> PWR_IN_LOW_ALA 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmapcAlmmoduleAlarm 1 }



--- *****************************************************
---     LEAF for the moduleWarning article
--- *****************************************************
pmapcAlmmoduleWarning OBJECT IDENTIFIER ::= { pmapcAlmOtherNurg 65 }




pmapcAlmEamAttHighWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        EAM Attenuation High Warning :EThis 
        OID indicates that the attenuation 
        of the EAM is higher than the warning 
        threshold  <Help>   This warning 
        indicates if the attenuation of 
        the EAM is too high <Condtype>
         EAM_ATT_HIGH_WNG <Probcause> equipmentMalfunction 
        (16) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmmoduleWarning 6 }



pmapcAlmEamAttLowWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        EAM Attenuation Low Warning :This 
        OID indicates that the attenuation 
        of the EAM is lower than the warning 
        threshold  <Help>   This warning 
        indicates if the attenuation of 
        the EAM is too low <Condtype> EAM_ATT_LOW_WNG 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmmoduleWarning 5 }



pmapcAlmPwrOutHighWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Power Output High Warning :This 
        OID indicates that Output power 
        of the transmit side is higher
         than the warning threshold   <Help> 
          This warning indicates if the 
        transmit power on the transmit
         side  is too high <Condtype> PWR_OUT_HIGH_WNG 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmmoduleWarning 4 }



pmapcAlmPwrOutLowWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Power Output Low Warning :This 
        OID indicates that Output power 
        of the transmit side is lower than 
        the warning threshold  <Help> 
          This warning indicates if the 
        transmit power on the transmit
         side  is too low <Condtype> PWR_OUT_LOW_WNG 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmmoduleWarning 3 }



pmapcAlmPwrInHighWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Power Input High Warning :This 
        OID indicates that input power
         of the transmit side is higher 
        than the warning threshold   <Help> 
          This warning indicates if the 
        received power on the transmit
         side  is too high <Condtype> PWR_IN_HIGH_WNG 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmapcAlmmoduleWarning 2 }



pmapcAlmPwrInLowWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Power Input Low Warning :This
         OID indicates that input power 
        of the transmit side is lower than 
        the warning threshold  <Help> 
          This warning indicates if the 
        received power on the transmit
         side  is too low <Condtype> PWR_IN_LOW_WNG 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmapcAlmmoduleWarning 1 }



--- *****************************************************
---     LEAF for the modInitFailLevel2 article
--- *****************************************************
pmapcAlmmodInitFailLevel2 OBJECT IDENTIFIER ::= { pmapcAlmOtherUrg 70 }




pmapcAlmThreshConfFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Thresh_Conf_Fail : <Condtype>
         THRESH_CONF_FAIL <Probcause> equipmentMalfunction 
        (16) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmapcAlmmodInitFailLevel2 7 }



pmapcAlmCalibReadFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Calib_Read_Fail : <Condtype> CALIB_READ_FAIL 
        <Probcause> softwareError (47)
         <Alarmtype> processingErrorAlarm 
        (4) <Polarity> (2) 
        "
	  ::= { pmapcAlmmodInitFailLevel2 6 }



pmapcAlmInvReadFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
         : <Condtype> INV_READ_FAIL <Probcause> 
        softwareError (47) <Alarmtype>
         processingErrorAlarm (4) <Polarity> 
        (2) 
        "
	  ::= { pmapcAlmmodInitFailLevel2 4 }



pmapcAlmConfReadFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Conf_Read_Fail : <Condtype> CONF_READ_FAIL 
        <Probcause> softwareError (47)
         <Alarmtype> processingErrorAlarm 
        (4) <Polarity> (2) 
        "
	  ::= { pmapcAlmmodInitFailLevel2 3 }



pmapcAlmResetHwInitFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Reset_HW_Init_Fail : <Condtype> 
        RESET_HW_INIT_FAIL <Probcause>
         softwareError (47) <Alarmtype> 
        processingErrorAlarm (4) <Polarity> 
        (2) 
        "
	  ::= { pmapcAlmmodInitFailLevel2 2 }



pmapcAlmRegReadFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Reg_Read_Fail : <Condtype> REG_READ_FAIL 
        <Probcause> softwareError (47)
         <Alarmtype> processingErrorAlarm 
        (4) <Polarity> (2) 
        "
	  ::= { pmapcAlmmodInitFailLevel2 1 }



--- *****************************************************
---     LEAF for the modInitFailLevel3 article
--- *****************************************************
pmapcAlmmodInitFailLevel3 OBJECT IDENTIFIER ::= { pmapcAlmOtherUrg 71 }




pmapcAlmOptIdentFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Opt_Ident_Fail : <Condtype> OPT_IDENT_FAIL 
        <Probcause> softwareError (47)
         <Alarmtype> processingErrorAlarm 
        (4) <Polarity> (2) 
        "
	  ::= { pmapcAlmmodInitFailLevel3 1 }








--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     CONTROLS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the synth0 article
--- *****************************************************
pmapcCtrlsynth0 OBJECT IDENTIFIER ::= { pmapcCtrlOther 0 }




pmapcCtrlConfClear OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Clear Configuration Tables :This 
        bit clears the configuration tables 
        from configuration in the flash. 
         <Help>    This control restores 
        the default configuration of the 
        module
        "
	  ::= { pmapcCtrlsynth0 13 }



pmapcCtrlConfFlash OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Write Configuration Tables :This 
        bit saves the current configuration 
        of the module as configuration
         in the flash.  <Help>    This
         control saves the customer configuration 
        on the module
        "
	  ::= { pmapcCtrlsynth0 9 }



pmapcCtrlConfLoad OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Load Configuration Tables :When 
        set this enables loading from flash 
        configuration1 into the module.
        "
	  ::= { pmapcCtrlsynth0 1 }



--- *****************************************************
---     LEAF for the synth4 article
--- *****************************************************
pmapcCtrlsynth4 OBJECT IDENTIFIER ::= { pmapcCtrlOther 4 }




pmapcCtrlCorrelatOff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Disable Alarm Correlation :This 
        OID disables the alarm correlation 
        in the PM.
        "
	  ::= { pmapcCtrlsynth4 2 }



pmapcCtrlCorrelatOn OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Enable Alarm Correlation :This 
        OID enables the alarm correlation 
        in the PM.
        "
	  ::= { pmapcCtrlsynth4 1 }



--- *****************************************************
---     LEAF for the swMgnt article
--- *****************************************************
pmapcCtrlswMgnt OBJECT IDENTIFIER ::= { pmapcCtrlOther 5 }




pmapcCtrlWarmReset OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        PM Warm Reset :This OID, when
         set, causes a warm reset of the 
        Software. This reset is not traffic 
        affecting, and the configuration 
        of the Sofwtare remains unchanged. 
         <Help>    This control initiates 
        a warm reset of the module.
        "
	  ::= { pmapcCtrlswMgnt 3 }



pmapcCtrlColdReset OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        PM Cold Reset :This OID, when
         set, causes a cold reset of the 
        Software. This reset is traffic 
        affecting, and the configuration 
        of Software is reloaded on start-up. 
         <Help>    This control initiates 
        a cold reset of the module.
        "
	  ::= { pmapcCtrlswMgnt 2 }



--- *****************************************************
---     LEAF for the laser1Shutdown article
--- *****************************************************
pmapcCtrllaser1Shutdown OBJECT IDENTIFIER ::= { pmapcCtrlClient 16 }




pmapcCtrlLaser1Shutdown OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Stuff. Wavelength 1 Laser Shutdown 
        :This OID shuts down the laser
         of the Stuffing Wavelength 1 
         <Help>    This control shuts down 
        the laser of the Stuffing Wavelength 
        1
        "
	  ::= { pmapcCtrllaser1Shutdown 1 }



--- *****************************************************
---     LEAF for the laser2Shutdown article
--- *****************************************************
pmapcCtrllaser2Shutdown OBJECT IDENTIFIER ::= { pmapcCtrlLine 17 }




pmapcCtrlLaser2Shutdown OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Stuff. Wavelength 2 Laser Shutdown 
        :This OID shuts down the laser
         of the Stuffing Wavelength 2 
         <Help>    This control shuts down 
        the laser of the Stuffing Wavelength 
        2
        "
	  ::= { pmapcCtrllaser2Shutdown 1 }



--- *****************************************************
---     LEAF for the laser1Oos article
--- *****************************************************
pmapcCtrllaser1Oos OBJECT IDENTIFIER ::= { pmapcCtrlClient 18 }




pmapcCtrlLaser1OosMode OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Stuff. Wavelength 1 Out Of Service 
        :This OID sets the Stuffing Wavelength 
        1 Out of Service  <Help>    This 
        controls defines the service state 
        of the Stuffing Wavelength 1
        "
	  ::= { pmapcCtrllaser1Oos 1 }



--- *****************************************************
---     LEAF for the laser2Oos article
--- *****************************************************
pmapcCtrllaser2Oos OBJECT IDENTIFIER ::= { pmapcCtrlLine 19 }




pmapcCtrlLaser2OosMode OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Stuff. Wavelength 2 Out Of Service 
        :This OID sets the Stuffing Wavelength 
        2 Out of Service  <Help>    This 
        controls defines the service state 
        of the Stuffing Wavelength 2
        "
	  ::= { pmapcCtrllaser2Oos 1 }



--- *****************************************************
---     LEAF for the ledTest article
--- *****************************************************
pmapcCtrlledTest OBJECT IDENTIFIER ::= { pmapcCtrlOther 64 }




pmapcCtrlLedOff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Leds Off :This OID switches off 
        all the Leds as a test feature. 
         <Help>    This control initiates 
        a test leds turning all the LEDs 
        to OFF
        "
	  ::= { pmapcCtrlledTest 3 }



pmapcCtrlRedLed OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Red Leds Test :This OID switches 
        on all the red Leds as a test feature. 
         <Help>    This control initiates 
        a test leds turning all the LEDs 
        to red
        "
	  ::= { pmapcCtrlledTest 2 }



pmapcCtrlGreenLed OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Green Leds Test :This OID switches 
        on all the green Leds as a test 
        feature.  <Help>    This control 
        initiates a test leds turning all 
        the LEDs to green
        "
	  ::= { pmapcCtrlledTest 1 }



--- *****************************************************
---     LEAF for the moduleOutputPwrSetting article
--- *****************************************************

pmapcCtrlmoduleOutputPwrSetting OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Module Output Power [-14 , +6] 
        :This OID sets the output power 
        of the module (AV=(Power/0.005)+32768) 
        (Unit = dBm)  <Help>   This control 
        defines the output power of the 
        module
        "
	  ::= { pmapcCtrlLine 65 }



--- *****************************************************
---     LEAF for the moduleInputPwrSetting article
--- *****************************************************

pmapcCtrlmoduleInputPwrSetting OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Module Input Power :This OID sets 
        the input power of the module (AV=(Power/0.005)+32768) 
        (Unit = dBm)  <Help>   This control 
        defines the input power of the
         module
        "
	  ::= { pmapcCtrlLine 66 }








--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     MEASURES
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the powerLas1 article
--- *****************************************************

pmapcMesrpowerLas1 OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Stuff, Wavelength 1 Power :This 
        OID gives the power value of the 
        Sutfing Wavelength 1 Laser (Power 
        = 10*log(AV)-40) (Unit = dBm) 
         <Help>   This measure gives the 
        optical power of the Stuffing Wavelength 
        1 Laser
        "
	  ::= { pmapcMesrClient 16 }



--- *****************************************************
---     LEAF for the vthLas1 article
--- *****************************************************

pmapcMesrvthLas1 OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Stuff. Wavelength 1 Temp. Reg. 
        Volt :This OID gives the Voltage 
        of the Temperature Regulator of 
        the Stuffing Wavelength 1 (Voltage 
        = AV/10000) (Unit = V)  <Help>
           This measure gives the Voltage 
        of the Temperature Regulator of 
        the Stuffing Wavelength 1
        "
	  ::= { pmapcMesrClient 17 }



--- *****************************************************
---     LEAF for the vtecLas1 article
--- *****************************************************

pmapcMesrvtecLas1 OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Stuff. Wavelength 1 TEC Voltage 
        :This OID gives the Voltage of
         the TEC of the Stuffing Wavelength 
        1 (Voltage = AV/10000) (Unit =
         V)  <Help>   This measure gives 
        the Voltage of the TEC of the Stuffing 
        Wavelength 1
        "
	  ::= { pmapcMesrClient 18 }



--- *****************************************************
---     LEAF for the iLas1 article
--- *****************************************************

pmapcMesriLas1 OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        :
        "
	  ::= { pmapcMesrClient 19 }



--- *****************************************************
---     LEAF for the powerLas2 article
--- *****************************************************

pmapcMesrpowerLas2 OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Stuff, Wavelength 2 Power :This 
        OID gives the power value of the 
        Sutfing Wavelength 2 Laser (Power 
        = 10*log(AV)-40) (Unit = dBm) 
         <Help>   This measure gives the 
        optical power of the Stuffing Wavelength 
        2 Laser
        "
	  ::= { pmapcMesrLine 24 }



--- *****************************************************
---     LEAF for the vthLas2 article
--- *****************************************************

pmapcMesrvthLas2 OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Stuff. Wavelength 2 Temp. Reg. 
        Volt :This OID gives the Voltage 
        of the Temperature Regulator of 
        the Stuffing Wavelength 2 (Voltage 
        = AV/10000) (Unit = V)  <Help>
           This measure gives the Voltage 
        of the Temperature Regulator of 
        the Stuffing Wavelength 2
        "
	  ::= { pmapcMesrLine 25 }



--- *****************************************************
---     LEAF for the vtecLas2 article
--- *****************************************************

pmapcMesrvtecLas2 OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Stuff. Wavelength 2 TEC Voltage 
        :This OID gives the Voltage of
         the TEC of the Stuffing Wavelength 
        2 (Voltage = AV/10000) (Unit =
         V)  <Help>   This measure gives 
        the Voltage of the TEC of the Stuffing 
        Wavelength 2
        "
	  ::= { pmapcMesrLine 26 }



--- *****************************************************
---     LEAF for the iLas2 article
--- *****************************************************

pmapcMesriLas2 OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        :
        "
	  ::= { pmapcMesrLine 27 }



--- *****************************************************
---     LEAF for the modulePowerIn article
--- *****************************************************

pmapcMesrmodulePowerIn OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Module Input Power :This OID gives 
        the input power of the module (Power=(AV-32768)*0.005) 
        (Unit = dBm)  <Help>  This measure 
        gives the input power of the module
        "
	  ::= { pmapcMesrOther 64 }



--- *****************************************************
---     LEAF for the moduleVPowerOut article
--- *****************************************************

pmapcMesrmoduleVPowerOut OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Module Output Power Voltage :This 
        OID gives the output power voltage 
        (Voltage = AV/10000) (Unit = V) 
         <Help>  This measure gives the 
        output power voltage of the module
        "
	  ::= { pmapcMesrOther 65 }



--- *****************************************************
---     LEAF for the moduleEamAtt article
--- *****************************************************

pmapcMesrmoduleEamAtt OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Stuffing Lasers Attenuation :This 
        OID gives the attenuation level 
        applied on the stuffing lasers
         in percent (0: not attenuation, 
        100: full attenuation)  (Attenuation 
        = AV) (Unit = %)  <Help>  This
         measure gives the attenuation
         level applied on the stuffing
         lasers in percent (0: not attenuation, 
        100: full attenuation)
        "
	  ::= { pmapcMesrOther 66 }



--- *****************************************************
---     LEAF for the moduleTemp article
--- *****************************************************

pmapcMesrmoduleTemp OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Module Temperature :This OID gives 
        the module temperature (Temperature 
        = AV/256) (Unit = C)  <Help>  This 
        measure gives the module temperature
        "
	  ::= { pmapcMesrOther 67 }



--- *****************************************************
---     LEAF for the module33v article
--- *****************************************************

pmapcMesrmodule33v OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Module 3.3 Voltage :This OID gives 
        the module 3V3 Voltage (Voltage 
        = AV/10000) (Unit = V)  <Help>
          This measure gives the module 
        3V3 Voltage
        "
	  ::= { pmapcMesrOther 68 }








--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     CONFIG
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the table Group lsd
--- *****************************************************

pmapcCfgLsd OBJECT IDENTIFIER ::= { pmapcConfig 1 }



--- *****************************************************
---     LEAF for the table NO_VALUE
--- *****************************************************

pmapctablecomaLsd OBJECT IDENTIFIER ::= { pmapcCfgLsd 1 }



--- *****************************************************
---     LEAF for the table Group startUp
--- *****************************************************

pmapcCfgStartUp OBJECT IDENTIFIER ::= { pmapcConfig 2 }



--- *****************************************************
---     LEAF for the table NO_VALUE
--- *****************************************************

pmapctablecomaStartup OBJECT IDENTIFIER ::= { pmapcCfgStartUp 1 }



pmapcCfglaser1Oos OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default setting on  laser 1 :This 
         register configures the default 
        service state on laser 1
        "
	  ::= { pmapctablecomaStartup 2 }



--- *****************************************************
---     LEAF for the table NO_VALUE
--- *****************************************************

pmapctablecombStartup OBJECT IDENTIFIER ::= { pmapcCfgStartUp 2 }



pmapcCfglaser2Oos OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default setting on  laser 2 :This 
         register configures the default 
        service state on laser 2
        "
	  ::= { pmapctablecombStartup 2 }



pmapcCfgmoduleOutputPwrSetting OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default setting on module output 
        power :This  register configures 
        the default output power level
         of the module
        "
	  ::= { pmapctablecombStartup 10 }



pmapcCfgmoduleInputPwrSetting OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default setting on module input 
        power :This  register configures 
        the default input power level of 
        the module
        "
	  ::= { pmapctablecombStartup 11 }



--- *****************************************************
---     LEAF for the table Group labels
--- *****************************************************

pmapcCfgLabels OBJECT IDENTIFIER ::= { pmapcConfig 3 }



--- *****************************************************
---     LEAF for the table NO_VALUE
--- *****************************************************

pmapcCfgLabelclientTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PmapcCfgLabelclientEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pmapcCfgLabels 1 }


pmapcCfgLabelclientEntry OBJECT-TYPE
	SYNTAX PmapcCfgLabelclientEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the labels
         table
        "
	INDEX   { pmapcCfgLabelclientIndex }
	::= { pmapcCfgLabelclientTable 1 }


PmapcCfgLabelclientEntry ::=
	SEQUENCE {
	pmapcCfgLabelclientIndex
		INTEGER,
	pmapcCfgLabelclientPortn
		DisplayString
	}


pmapcCfgLabelclientIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the labelclient 
        table
        "
	::= { pmapcCfgLabelclientEntry 1 }


pmapcCfgLabelclientPortn OBJECT-TYPE
	SYNTAX  DisplayString( SIZE(1..16))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default settings on the label
         of the Ports :These registers
         configures the default initialisation 
        settings of the labels of the ports.
        "
	::= { pmapcCfgLabelclientEntry 3 }


--- *****************************************************
---     LEAF for the table NO_VALUE
--- *****************************************************

pmapcCfgLabellineTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PmapcCfgLabellineEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pmapcCfgLabels 2 }


pmapcCfgLabellineEntry OBJECT-TYPE
	SYNTAX PmapcCfgLabellineEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the labels
         table
        "
	INDEX   { pmapcCfgLabellineIndex }
	::= { pmapcCfgLabellineTable 1 }


PmapcCfgLabellineEntry ::=
	SEQUENCE {
	pmapcCfgLabellineIndex
		INTEGER,
	pmapcCfgLabellinePortn
		DisplayString
	}


pmapcCfgLabellineIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the labelline 
        table
        "
	::= { pmapcCfgLabellineEntry 1 }


pmapcCfgLabellinePortn OBJECT-TYPE
	SYNTAX  DisplayString( SIZE(1..16))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default settings on the label
         of the lines :These registers
         configures the default initialisation 
        settings of the labels of the lines.
        "
	::= { pmapcCfgLabellineEntry 3 }



pmapcCfgWriteConfiguration  OBJECT-TYPE
	SYNTAX EkiOnOff
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
	"Write configuration to module:This OID 
	 writes the complete configuration to the module"
	::= { pmapcConfig 257 }






--- *****************************************************
---     TRAP OBJECTS
--- *****************************************************

pmapctrapPortNumber OBJECT-TYPE
	SYNTAX INTEGER(1..64)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
	"Last port which generates a trap"
	::= { pmapctraps 2 }

pmapctrapLineNumber OBJECT-TYPE
	SYNTAX INTEGER(1..64)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
	"Last Line which generates a trap"
	::= { pmapctraps 3 }

pmapctrapBoardNumber OBJECT-TYPE
	SYNTAX INTEGER(1..64)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
	"Last module which generates a trap"
	::= { pmapctraps 4 }







--- *****************************************************
---     Las2 TRAPS
--- *****************************************************

pmapcLas2TrapNotUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pmapcAlmLas2MeasWng, pmapctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMAPC Stuffing Laser 2 Not Urgent ON"
	--&ACTIONS     { log, minor }
	--&MATCH       { pmapcAlmLas2MeasWng "on", pmapctrapBoardNumber "$2"}
	--&MESG        "DDM Warning appears on Stuffing Laser 2 of PMAPC in slot $2 ($A)"
	DESCRIPTION "Not urgent Line default is activated"
	::= { pmapctraps 30 }

pmapcLas2TrapNotUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pmapcAlmLas2MeasWng, pmapctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMAPC Stuffing Laser 2 Not Urgent OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      { "PMAPC Stuffing Laser 2 Not Urgent ON"}
	--&MATCH       { pmapcAlmLas2MeasWng "on", pmapctrapBoardNumber "$2"}
	--&MESG        "DDM Warning disappears on Stuffing Laser 2 of PMAPC in slot $2 ($A)"
	DESCRIPTION "Not urgent Line default disappeared"
	::= { pmapctraps 31 }

pmapcLas2TrapUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pmapcAlmLas2MeasAlm, pmapctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMAPC Stuffing Laser 2 Urgent ON"
	--&ACTIONS     { log, major }
	--&MATCH       { pmapcAlmLas2MeasAlm "on", pmapctrapBoardNumber "$2"}
	--&MESG        "DDM Alarms appears on Stuffing Laser 2 of PMAPC in slot $2 ($A)"
	DESCRIPTION "Urgent Line default is activated"
	::= { pmapctraps 32 }

pmapcLas2TrapUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pmapcAlmLas2MeasAlm, pmapctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMAPC Stuffing Laser 2 Urgent OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      { "PMAPC Stuffing Laser 2 Urgent ON"}
	--&MATCH       { pmapcAlmLas2MeasAlm "on", pmapctrapBoardNumber "$2"}
	--&MESG        "DDM Alarm disappears on Stuffing Laser 2 of PMAPC in slot $2 ($A)"
	DESCRIPTION "Urgent Line default disappeared"
	::= { pmapctraps 33 }

pmapcLas2TrapCritGoesOn NOTIFICATION-TYPE
	OBJECTS {pmapcAlmLas2FailAcc , pmapcAlmLas2HwFailAcc, pmapctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMAPC Stuffing Laser 2 Fail ON"
	--&ACTIONS     { log, critical }
	--&MATCH       { pmapcAlmLas2FailAcc "on", pmapcAlmLas2HwFailAcc "*", pmapctrapBoardNumber "$3"}
	--&MESG        "Stuffing Laser 2 Down on PMAPC in Slot $3 ($A)"
	
	--&FILTNAME    "PMAPC Stuffing Laser 2 HW Fail ON (Hidden)"
	--&ACTIONS     { info }
	--&MATCH       { pmapcAlmLas2FailAcc "*", pmapcAlmLas2HwFailAcc "on", pmapctrapBoardNumber "$3"}
	--&MESG        "Stuffing Laser 2 Down on PMAPC in Slot $3 ($A)"
	DESCRIPTION "Critical Line default is activated"
	::= { pmapctraps 34 }

pmapcLas2TrapCritGoesOff NOTIFICATION-TYPE
	OBJECTS {pmapcAlmLas2FailAcc , pmapcAlmLas2HwFailAcc, pmapctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMAPC Stuffing Laser 2 Fail OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      { "PMAPC Stuffing Laser 2 Fail ON" }
	--&MATCH       { pmapcAlmLas2FailAcc "on", pmapcAlmLas2HwFailAcc "*", pmapctrapBoardNumber "$3"}
	--&MESG        "Stuffing Laser 2 Up on PMAPC in Slot $3 ($A)"

	--&FILTNAME    "PMAPC Stuffing Laser 2 HW Fail OFF (Hidden)"
	--&ACTIONS     { info }
	--&MATCH       { pmapcAlmLas2FailAcc "*", pmapcAlmLas2HwFailAcc "on", pmapctrapBoardNumber "$3"}
	--&MESG        "Stuffing Laser 2 Up on PMAPC in Slot $3 ($A)"
	DESCRIPTION "Critical Line default disappeared"
	::= { pmapctraps 35 }






--- *****************************************************
---     Las1 TRAPS
--- *****************************************************

pmapcLas1TrapNotUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pmapcAlmLas1MeasWng, pmapctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMAPC Stuffing Laser 1 Not Urgent ON"
	--&ACTIONS     { log, minor }
	--&MATCH       { pmapcAlmLas1MeasWng "on", pmapctrapBoardNumber "$2"}
	--&MESG        "DDM Warning appears on Stuffing Laser 1 of PMAPC in slot $2 ($A)"
	DESCRIPTION "Not urgent client default is activated"
	::= { pmapctraps 40 }

pmapcLas1TrapNotUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pmapcAlmLas1MeasWng, pmapctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMAPC Stuffing Laser 1 Not Urgent OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      { "PMAPC Stuffing Laser 1 Not Urgent ON"}
	--&MATCH       { pmapcAlmLas1MeasWng "on", pmapctrapBoardNumber "$2"}
	--&MESG        "DDM Warning disappears on Stuffing Laser 1 of PMAPC in slot $2 ($A)"
	DESCRIPTION "Not urgent client default disappeared"
	::= { pmapctraps 41 }

pmapcLas1TrapUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pmapcAlmLas1MeasAlm, pmapctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMAPC Stuffing Laser 1 Urgent ON"
	--&ACTIONS     { log, major }
	--&MATCH       { pmapcAlmLas1MeasAlm "on", pmapctrapBoardNumber "$2"}
	--&MESG        "DDM Alarms appears on Stuffing Laser 1 of PMAPC in slot $2 ($A)"
	DESCRIPTION "Urgent client default is activated"
	::= { pmapctraps 42 }

pmapcLas1TrapUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pmapcAlmLas1MeasAlm, pmapctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMAPC Stuffing Laser 1 Urgent OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      { "PMAPC Stuffing Laser 1 Urgent ON"}
	--&MATCH       { pmapcAlmLas1MeasAlm "on", pmapctrapBoardNumber "$2"}
	--&MESG        "DDM Alarm disappears on Stuffing Laser 1 of PMAPC in slot $2 ($A)"
	DESCRIPTION "Urgent client default disappeared"
	::= { pmapctraps 43 }

pmapcLas1TrapCritGoesOn NOTIFICATION-TYPE
	OBJECTS {pmapcAlmLas1FailAcc, pmapcAlmLas1HwFailAcc, pmapctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMAPC Stuffing Laser 1 Fail ON"
	--&ACTIONS     { log, critical }
	--&MATCH       { pmapcAlmLas1FailAcc "on", pmapcAlmLas1HwFailAcc "*", pmapctrapBoardNumber "$3"}
	--&MESG        "Stuffing Laser 1 Down on PMAPC in Slot $3 ($A)"
	
	--&FILTNAME    "PMAPC Stuffing Laser 1 HW Fail ON (Hidden)"
	--&ACTIONS     { info }
	--&MATCH       { pmapcAlmLas1FailAcc "*", pmapcAlmLas1HwFailAcc "on", pmapctrapBoardNumber "$3"}
	--&MESG        "Stuffing Laser 1 Down on PMAPC in Slot $3 ($A)"
	DESCRIPTION "Critical client default is activated"
	::= { pmapctraps 44 }

pmapcLas1TrapCritGoesOff NOTIFICATION-TYPE
	OBJECTS {pmapcAlmLas1FailAcc, pmapcAlmLas1HwFailAcc, pmapctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMAPC Stuffing Laser 1 Fail OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      { "PMAPC Stuffing Laser 1 Fail ON" }
	--&MATCH       { pmapcAlmLas1FailAcc "on", pmapcAlmLas1HwFailAcc "*", pmapctrapBoardNumber "$3"}
	--&MESG        "Stuffing Laser 1 Up on PMAPC in Slot $3 ($A)"

	--&FILTNAME    "PMAPC Stuffing Laser 1 HW Fail OFF (Hidden)"
	--&ACTIONS     { info }
	--&MATCH       { pmapcAlmLas1FailAcc "*", pmapcAlmLas1HwFailAcc "on", pmapctrapBoardNumber "$3"}
	--&MESG        "Stuffing Laser 1 Up on PMAPC in Slot $3 ($A)"
	DESCRIPTION "Critical client default disappeared"
	::= { pmapctraps 45 }






--- *****************************************************
---     HW TRAPS
--- *****************************************************

pmapcPowerTrapUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pmapcAlmDefFuseB, pmapcAlmDefFuseA , pmapctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMAPC Fuse A Fail ON"
	--&ACTIONS     { log, major }
	--&MATCH       { pmapcAlmDefFuseB "*", pmapcAlmDefFuseA "on", pmapctrapBoardNumber "$3"}
	--&MESG        "Power Input A Fail on PMAPC in Slot $3 ($A)"

	--&FILTNAME    "PMAPC Fuse B Fail ON"
	--&ACTIONS     { log, major }
	--&MATCH       { pmapcAlmDefFuseB "on", pmapcAlmDefFuseA "*", pmapctrapBoardNumber "$3"}
	--&MESG        "Power Input B Fail on PMAPC in Slot $3 ($A)"
	DESCRIPTION "Urgent power supply default is activated"
	::= { pmapctraps 50 }

pmapcPowerTrapUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pmapcAlmDefFuseB, pmapcAlmDefFuseA , pmapctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMAPC Fuse A&B Fail OFF"
	--&ACTIONS     { log, normal}
	--&CLEARS      { "PMAPC Fuse A Fail ON", "PMAPC Fuse B Fail ON" }
	--&MATCH       { pmapcAlmDefFuseB "on", pmapcAlmDefFuseA "on", pmapctrapBoardNumber "$3"}
	--&MESG        "Power Inputs A and B Present on PMAPC in Slot $3 ($A)"
	DESCRIPTION "Urgent power supply default disappeared"
	::= { pmapctraps 51 }