-- EKINOPS-pmoabphc.TXT:  MIB
--
--MIB Part Number:3MI00208AABE
--MIB Version:01
--
-- Copyright (c) 2016 by Ekinops
-- All rights reserved.
-- 
-- *****************************************************************

EKINOPS-PmOabphc-MIB DEFINITIONS ::= BEGIN

IMPORTS
	ekinops,
	EkiState,
	EkiOnOff,
	EkiMode,
	EkiProtocol,
	EkiApiState,
	EkiSynchroMode,
	EkiMeasureType
			FROM EKINOPS-MIB
        MODULE-IDENTITY,
        OBJECT-TYPE,
        NOTIFICATION-TYPE,
	Unsigned32,
	Integer32,
	Counter32,
	IpAddress                
        		FROM SNMPv2-SMI
 	TEXTUAL-CONVENTION,
	DisplayString
                FROM SNMPv2-TC;

modulepmoabphc MODULE-IDENTITY
        LAST-UPDATED "201605230000Z"
        ORGANIZATION "Ekinops"
        CONTACT-INFO
         "Ekinops

          3, rue Blaise Pascal
          F-22300 Lannion / FRANCE

          Tel : +33 (0)2 96 05 00 30
          Fax : +33 (0)2 96 48 62 39

          E-mail: support@ekinops.net"
        DESCRIPTION
          "Creation"
	REVISION "201107060000Z"
	DESCRIPTION
	  "Initial Version."
	
	REVISION "201107060000Z"
	DESCRIPTION
	  "Creation"
	REVISION "201302080000Z"
	DESCRIPTION
	  "Ext Pump alarms"
	REVISION "201307010000Z"
	DESCRIPTION
	  "Constant Gain function"
	REVISION "201309160000Z"
	DESCRIPTION
	  "Help change"
	REVISION "201312020000Z"
	DESCRIPTION
	  "Ext Pump Fail insertion"
	REVISION "201403260000Z"
	DESCRIPTION
	  "Probcause,AlarmType - NMS completion"
	REVISION "201412100000Z"
	DESCRIPTION
	  "Labels cosmetic updates"
	REVISION "201605230000Z"
	DESCRIPTION
	  "New AlarmType  synthesisAlarm (12)"
        ::= { ekinops 51 }



--- *****************************************************
---     LEAF LEVEL 2
--- *****************************************************


pmoabphcalarms OBJECT IDENTIFIER ::= { modulepmoabphc 2 }	
pmoabphcAlmOther OBJECT IDENTIFIER ::= { pmoabphcalarms 1 }
pmoabphcAlmOtherNurg OBJECT IDENTIFIER ::= { pmoabphcAlmOther 1 }
pmoabphcAlmOtherUrg OBJECT IDENTIFIER ::= { pmoabphcAlmOther 2 }
pmoabphcAlmOtherCrit OBJECT IDENTIFIER ::= { pmoabphcAlmOther 3 }

pmoabphcAlmClient OBJECT IDENTIFIER ::= { pmoabphcalarms 2 }
pmoabphcAlmClientNurg OBJECT IDENTIFIER ::= { pmoabphcAlmClient 1 }
pmoabphcAlmClientUrg OBJECT IDENTIFIER ::= { pmoabphcAlmClient 2 }
pmoabphcAlmClientCrit OBJECT IDENTIFIER ::= { pmoabphcAlmClient 3 }
	
pmoabphcAlmLine OBJECT IDENTIFIER ::= { pmoabphcalarms 3 }
pmoabphcAlmLineNurg OBJECT IDENTIFIER ::= { pmoabphcAlmLine 1 }
pmoabphcAlmLineUrg OBJECT IDENTIFIER ::= { pmoabphcAlmLine 2 }
pmoabphcAlmLineCrit OBJECT IDENTIFIER ::= { pmoabphcAlmLine 3 }


pmoabphcmeasures OBJECT IDENTIFIER ::= { modulepmoabphc 3 }	
pmoabphcMesrOther OBJECT IDENTIFIER ::= { pmoabphcmeasures 1 }	
pmoabphcMesrClient OBJECT IDENTIFIER ::= { pmoabphcmeasures 2 }	
pmoabphcMesrLine OBJECT IDENTIFIER ::= { pmoabphcmeasures 3 }	


pmoabphccontrolsWrite OBJECT IDENTIFIER ::= { modulepmoabphc 6 }
pmoabphcCtrlOther OBJECT IDENTIFIER ::= { pmoabphccontrolsWrite 1 }
pmoabphcCtrlClient OBJECT IDENTIFIER ::= { pmoabphccontrolsWrite 2 }
pmoabphcCtrlLine OBJECT IDENTIFIER ::= { pmoabphccontrolsWrite 3 }

pmoabphcri OBJECT IDENTIFIER ::= { modulepmoabphc 7 }


pmoabphcConfig OBJECT IDENTIFIER ::= { modulepmoabphc 9 }

pmoabphctraps OBJECT IDENTIFIER ::= { modulepmoabphc 10 }


--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     TEXTUAL-CONVENTION
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************


PmoabphcpreampMode ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION "Different modes on OA preamp"
    SYNTAX INTEGER {
		oabphcpreampdefaultmode(0),
		oabphcpreampconstantcurrentmode(1),
		oabphcpreampconstantpowermode(2)
		oabphcpreampconstantgainmode(3)
		oabphcpreamppoutpinmode(4)
		oabphcpreampmanualmode(5)
		oabphcpreampfeedforwardmode(6)
		oabphcpreamptransientsupmode(7)

           }

PmoabphcboosterMode ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION "Different modes on OA booster"
    SYNTAX INTEGER {
		oabphcboosterdefaultmode(0),
		oabphcboosterconstantcurrentmode(1),
		oabphcboosterconstantpowermode(2)
		oabphcboosterconstantgainmode(3)
		oabphcboosterpoutpinmode(4)
		oabphcboostermanualmode(5)
		oabphcboosterfeedforwardmode(6)
		oabphcboostertransientsupmode(7)
           }


PmoabphcaprMode ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION "Different modes on APR"
    SYNTAX INTEGER {
		oabphcaproffmode(0),
		oabphcaprsemiautomode(1),
		oabphcaprautomode(2)
		oabphcaprlossforwardingmode(3)
		oabphcaprrepeatmode(4)

           }

PmoabphcPreampGainAdjMode ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION "Different modes on Gain"
    SYNTAX INTEGER {
		oabphcpreampgainadjmanualmode(0),
		oabphcpreampgainadjsemiautomode(1),
		oabphcpreampgainadjautomode(2)

           }

PmoabphcBoosterGainAdjMode ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION "Different modes on Gain"
    SYNTAX INTEGER {
		oabphcboostergainadjmanualmode(0),
		oabphcboostergainadjsemiautomode(1),
		oabphcboostergainadjautomode(2)

           }

PmoabphcPreampCstGainAdjMode ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION "Different modes when constant Gain"
    SYNTAX INTEGER {
		oabphcpreampcstgainadjsemiautomode(1),
		oabphcpreampcstgainadjautomode(2)

           }

PmoabphcBoosterCstGainAdjMode ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION "Different modes when constant Gain"
    SYNTAX INTEGER {
		oabphcboostercstgainadjsemiautomode(1),
		oabphcboostercstgainadjautomode(2)

           }


--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     REMOTE INVENTORY
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************

pmoabphcRinvReloadInventory OBJECT-TYPE
  SYNTAX EkiOnOff
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
        "Reload the inventory: This OID triggers an 
         inventory reload."
  ::= { pmoabphcri 2 }
  
pmoabphcRinvModulePlatform OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
        "Module platform description: This OID contains the 
         description of the Module."
  ::= { pmoabphcri 3 }
  
pmoabphcRinvSwPlatform OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
        "SW platform description: This OID contains the 
         description of the Software platform."
  ::= { pmoabphcri 4 }

pmoabphcRinvSwFoa OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
        "Optical device driver description: This OID contains
	 the description of the driver of the optical devices 
	(Booster and Pre-Amp)"
  ::= { pmoabphcri 5 }
  
  
pmoabphcRinvBoosterTable OBJECT-TYPE
      SYNTAX  SEQUENCE OF PmoabphcRinvBoosterEntry
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
              "List of the Boosters on the selected module"
      ::= { pmoabphcri 6 }

pmoabphcRinvBoosterEntry OBJECT-TYPE
        SYNTAX  PmoabphcRinvBoosterEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
              "Row definition for the Boosters table"
        INDEX   { pmoabphcRinvBoosterIndex }
        ::= { pmoabphcRinvBoosterTable 1 }
    


PmoabphcRinvBoosterEntry::=
        SEQUENCE {
          pmoabphcRinvBoosterIndex 
              Integer32,
          pmoabphcRinvBooster
              DisplayString
        }


    pmoabphcRinvBoosterIndex OBJECT-TYPE
        SYNTAX  Integer32(1..16)
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
              "Index for Booster table"
        ::= { pmoabphcRinvBoosterEntry 1 }


    pmoabphcRinvBooster OBJECT-TYPE
        SYNTAX  DisplayString
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
              "Inventory for the Booster: This OID contains the inventory for the Booster"
        ::= { pmoabphcRinvBoosterEntry 2 }




pmoabphcRinvPreAmpTable OBJECT-TYPE
      SYNTAX  SEQUENCE OF PmoabphcRinvPreAmpEntry
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
              "List of the PreAmps on the selected module"
      ::= { pmoabphcri 7 }

pmoabphcRinvPreAmpEntry OBJECT-TYPE
        SYNTAX  PmoabphcRinvPreAmpEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
              "Row definition for the PreAmp table"
        INDEX   { pmoabphcRinvPreAmpIndex }
        ::= { pmoabphcRinvPreAmpTable 1 }
    


PmoabphcRinvPreAmpEntry::=
        SEQUENCE {
          pmoabphcRinvPreAmpIndex 
              Integer32,
          pmoabphcRinvPreAmp
              DisplayString
        }


    pmoabphcRinvPreAmpIndex OBJECT-TYPE
        SYNTAX  Integer32(1..16)
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
              "Index for PreAmp table"
        ::= { pmoabphcRinvPreAmpEntry 1 }


    pmoabphcRinvPreAmp OBJECT-TYPE
        SYNTAX  DisplayString
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
              "Inventory for the PreAmp: This OID contains the inventory for the PreAmp"
        ::= { pmoabphcRinvPreAmpEntry 2 }



  




--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     ALARMS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the synthAlm0 article
--- *****************************************************
pmoabphcAlmsynthAlm0 OBJECT IDENTIFIER ::= { pmoabphcAlmOtherCrit 0 }




pmoabphcAlmDefFuseB OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Fuse B Fail :This OID indicates 
        that the fuse of the power input 
        B is in fail condition  <Help>
          Status of the Fuse B <Condtype> 
        DEF_FUSE_B <Probcause> powerProblem 
        (36) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmsynthAlm0 16 }



pmoabphcAlmDefFuseA OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Fuse A Fail :This OID indicates 
        that the fuse of the power input 
        A is in fail condition  <Help>
          Status of the Fuse A <Condtype> 
        DEF_FUSE_A <Probcause> powerProblem 
        (36) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmsynthAlm0 15 }



pmoabphcAlmExtPump2NotLocked OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        External Pump2 Not Detected :This 
        OID indicates that the second external 
        pump is not detected by the amplifier 
        module  <Help>  This alarm indicates 
        if the second external pump is
         detected by the amplifier module 
        <Condtype> EXT_PUMP2_NOT_LOCKED 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmsynthAlm0 13 }



pmoabphcAlmExtPump1NotLocked OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        External Pump1 Not Detected :This 
        OID indicates that the first external 
        pump is not detected by the amplifier 
        module  <Help>  This alarm indicates 
        if the first external pump is detected 
        by the amplifier module <Condtype> 
        EXT_PUMP1_NOT_LOCKED <Probcause> 
        pumpFailure (39) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmsynthAlm0 12 }



pmoabphcAlmDwEdfaInitNotCompl OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Not Initialized :This
         OID indicates that the initialisation 
        of the Pre-Amp is not completed 
         <Help>  This status indicates
         if the Pre-Amp has been correctly 
        initialized <Condtype> DW_EDFA_INIT_NOT_COMPL 
        <Probcause> other (1) <Alarmtype> 
        other (1) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmsynthAlm0 11 }



pmoabphcAlmUpEdfaInitNotCompl OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Not Initialized :This
         OID indicates that the initialisation 
        of the Booster is not completed 
         <Help>  This status indicates
         if the Booster has been correctly 
        initialized <Condtype> UP_EDFA_INIT_NOT_COMPL 
        <Probcause> other (1) <Alarmtype> 
        other (1) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmsynthAlm0 10 }



pmoabphcAlmModGlobFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Module Failure :This OID is set 
        on detection of a failure originating 
        from the PM <Condtype> MOD_GLOB_FAIL 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	  ::= { pmoabphcAlmsynthAlm0 9 }



pmoabphcAlmAprOn OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Automatic Power Reduction :This 
        OID indicates that the APR algorithm 
        has been operated and the  output 
        of the lasers are shutdown  <Help> 
          The APR algorithm has been completed 
         <Condtype> APR_ON <Probcause>
         other (1) <Alarmtype> other (1) 
        <Polarity> (2) 
        "
	  ::= { pmoabphcAlmsynthAlm0 2 }



pmoabphcAlmMaintenanceMode OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Maintenance Mode :This OID indicates 
        that the PM is in maintenance mode 
         <Help>  This status indiates if 
        the module is currently in maintenance 
        mode <Condtype> MAINTENANCE_MODE 
        <Probcause> other (1) <Alarmtype> 
        other (1) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmsynthAlm0 1 }



--- *****************************************************
---     LEAF for the synthAlm2 article
--- *****************************************************
pmoabphcAlmsynthAlm2 OBJECT IDENTIFIER ::= { pmoabphcAlmOtherNurg 2 }




pmoabphcAlmConfTableLoad OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        PM Configuration Load :This OID 
         is at 1 during the loading of
         configuration tables in the modules 
        RAM. <Condtype> CONF_TABLE_LOAD 
        <Probcause> bandwidthReduced(4) 
        <Alarmtype> other (1) <Polarity> 
        (2) 
        "
	  ::= { pmoabphcAlmsynthAlm2 3 }



pmoabphcAlmInvUpload OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Inventory Upload :This OID is
         at 1 during the uploading of PM 
        inventory information. <Condtype> 
        INV_UPLOAD <Probcause> bandwidthReduced(4) 
        <Alarmtype> other (1) <Polarity> 
        (2) 
        "
	  ::= { pmoabphcAlmsynthAlm2 2 }



pmoabphcAlmConfTableSave OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        PM Configuration Save :This OID 
        is at 1 during the saving of a
         new configuration table in the 
        module Flash memory. <Condtype> 
        CONF_TABLE_SAVE <Probcause> bandwidthReduced(4) 
        <Alarmtype> other (1) <Polarity> 
        (2) 
        "
	  ::= { pmoabphcAlmsynthAlm2 1 }



--- *****************************************************
---     LEAF for the synthAlm7 article
--- *****************************************************
pmoabphcAlmsynthAlm7 OBJECT IDENTIFIER ::= { pmoabphcAlmLineCrit 7 }




pmoabphcAlmLineExtPumpFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster External Pump Fail :This 
        OID indicates that the external 
        pump linked to the Booster is in 
        fail condition   <Help>  This alarm 
        indicates if the external pump
         linked to the Booster is in fail 
        condition <Condtype> LINE_EXT_PUMP_FAIL 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmsynthAlm7 13 }



pmoabphcAlmLineFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line Port Failure :This OID indicates 
        a failure on the line port <Condtype> 
        LINE_FAIL <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	  ::= { pmoabphcAlmsynthAlm7 12 }



pmoabphcAlmLineDdmAlm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Alarm On Line Optical Module DDM 
        :This OID indicates an alarm is 
        present coming out of Line optical 
        interface DDM <Condtype> LINE_DDM_ALM 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	  ::= { pmoabphcAlmsynthAlm7 10 }



pmoabphcAlmLineDdmWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Warning On Line Optical Module 
        DDM :This OID indicates a warning 
        is present coming out of Line optical 
        interface DDM <Condtype> LINE_DDM_WARNING 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	  ::= { pmoabphcAlmsynthAlm7 9 }



pmoabphcAlmLineTxOff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Optical Output Shutdown 
        :This OID indicates the Booster 
        optical output power is on  <Help> 
         This status indicates if the Booster 
        laser pump is ON or OFF <Condtype> 
        LINE_TX_OFF <Probcause> other (1) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmoabphcAlmsynthAlm7 5 }



pmoabphcAlmLineHwFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line Port HW Failure :This OID 
        indicates a failure on line port, 
        most probably caused by a HW issue 
        <Condtype> LINE_HW_FAIL <Probcause> 
        equipmentMalfunction (16) <Alarmtype> 
        synthesisAlarm (12)  <Polarity> 
        (2) 
        "
	  ::= { pmoabphcAlmsynthAlm7 4 }



--- *****************************************************
---     LEAF for the synthAlm8 article
--- *****************************************************
pmoabphcAlmsynthAlm8 OBJECT IDENTIFIER ::= { pmoabphcAlmClientCrit 8 }




pmoabphcAlmClientExtPumpFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp External Pump Fail :This 
        OID indicates that the external 
        pump linked to the Pre-Amp is in 
        fail condition   <Help>  This alarm 
        indicates if the external pump
         linked to the Pre-Amp is in fail 
        condition <Condtype> CLIENT_EXT_PUMP_FAIL 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmsynthAlm8 13 }



pmoabphcAlmClientFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Client Port Failure :This OID
         indicates a failure on the Client 
        port <Condtype> CLIENT_FAIL <Probcause> 
        equipmentMalfunction (16) <Alarmtype> 
        synthesisAlarm (12)  <Polarity> 
        (2) 
        "
	  ::= { pmoabphcAlmsynthAlm8 12 }



pmoabphcAlmClientDdmAlm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Alarm On Client Optical Module 
        DDM :This OID indicates an alarm 
        is present coming out of Client 
        optical interface DDM <Condtype> 
        CLIENT_DDM_ALM <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	  ::= { pmoabphcAlmsynthAlm8 10 }



pmoabphcAlmClientDdmWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Warning On Client Optical Module 
        DDM :This OID indicates a warning 
        is present coming out of Client 
        optical interface DDM <Condtype> 
        CLIENT_DDM_WARNING <Probcause>
         equipmentMalfunction (16) <Alarmtype> 
        synthesisAlarm (12)  <Polarity> 
        (2) 
        "
	  ::= { pmoabphcAlmsynthAlm8 9 }



pmoabphcAlmClientTxOff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Optical Output Shutdown 
        :This OID indicates the Pre-Amp 
        optical output power is on  <Help> 
         This status indicates if the Pre-Amp 
        laser pump transceiver laser is 
        ON or OFF <Condtype> CLIENT_TX_OFF 
        <Probcause> other (1) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmsynthAlm8 5 }



pmoabphcAlmClientHwFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Client Port HW Failure :This OID 
        indicates a failure on Client port, 
        most probably caused by a HW issue 
        <Condtype> CLIENT_HW_FAIL <Probcause> 
        equipmentMalfunction (16) <Alarmtype> 
        synthesisAlarm (12)  <Polarity> 
        (2) 
        "
	  ::= { pmoabphcAlmsynthAlm8 4 }



--- *****************************************************
---     LEAF for the clientEdfaAlarms1 article
--- *****************************************************
pmoabphcAlmclientEdfaAlarms1 OBJECT IDENTIFIER ::= { pmoabphcAlmClientUrg 32 }




pmoabphcAlmClientBiasHighAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Bias High Alarm :This
         OID indicates that the Bias is 
        higher than the alarm theshold
         of the Pre-Amp Optical Module
          <Help>  This alarm indicates
         if the Pre-Amp bias is too high 
        <Condtype> CLIENT_BIAS_HIGH_ALARM 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmclientEdfaAlarms1 8 }



pmoabphcAlmClientBiasLowAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Bias Low Alarm :This OID 
        indicates that the Bias is lower 
        than the alarm theshold of the
         Pre-Amp Optical Module  <Help> 
         This alarm indicates if the Pre-Amp 
        bias is too low <Condtype> CLIENT_BIAS_LOW_ALARM 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmclientEdfaAlarms1 7 }



pmoabphcAlmClientOutputPwrHighAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Tx Pwr High Alarm :This 
        OID indicates that the Transmit 
        Power is higher than the alarm
         theshold of the Pre-Amp Optical 
        Module  <Help>  This alarm indicates 
        if the Pre-Amp tx power is too
         high <Condtype> CLIENT_OUTPUT_PWR_HIGH_ALARM 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmclientEdfaAlarms1 6 }



pmoabphcAlmClientOutputPwrLowAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Tx Pwr Low Alarm :This 
        OID indicates that the Transmit 
        Power is lower than the alarm theshold 
        of the Pre-Amp Optical Module 
         <Help>  This alarm indicates if 
        the Pre-Amp tx power is too low 
        <Condtype> CLIENT_OUTPUT_PWR_LOW_ALARM 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmclientEdfaAlarms1 5 }



pmoabphcAlmClientInputPwrHighAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Rx Pwr High Alarm :This 
        OID indicates that the Receive
         Power is higher than the alarm 
        theshold of the Booster Optical 
        Module  <Help>  This alarm indicates 
        if the Booster rx power is too
         high <Condtype> CLIENT_INPUT_PWR_HIGH_ALARM 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmoabphcAlmclientEdfaAlarms1 4 }



pmoabphcAlmClientInputPwrLowAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Rx Pwr Low Alarm :This 
        OID indicates that the Receive
         Power is lower than the alarm
         theshold of the Booster Optical 
        Module  <Help>  This alarm indicates 
        if the Booster rx power is too
         low <Condtype> CLIENT_INPUT_PWR_LOW_ALARM 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmoabphcAlmclientEdfaAlarms1 3 }



pmoabphcAlmClientGainHighAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Gain High Alarm :This
         OID indicates that the Gain is 
        higher than the alarm threshold 
        of the Pre-Amp Module  <Help> 
         This alarm indicates if the Pre-Amp 
        gain is too high <Condtype> CLIENT_GAIN_HIGH_ALARM 
        <Probcause> performanceDegraded 
        (35) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmclientEdfaAlarms1 2 }



pmoabphcAlmClientGainLowAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Gain Low Alarm :This OID 
        indicates that the Gain is lower 
        than the alarm theshold of the
         Pre-Amp Module  <Help>  This alarm 
        indicates if the Pre-Amp gain is 
        too low <Condtype> CLIENT_GAIN_LOW_ALARM 
        <Probcause> performanceDegraded 
        (35) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmclientEdfaAlarms1 1 }



--- *****************************************************
---     LEAF for the clientEdfaWarnings article
--- *****************************************************
pmoabphcAlmclientEdfaWarnings OBJECT IDENTIFIER ::= { pmoabphcAlmClientNurg 33 }




pmoabphcAlmClientBiasHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Bias High Warning :This 
        OID indicates that the Bias is
         higher than the Warning theshold 
        of the Pre-Amp Optical Module 
         <Help>  This warning indicates 
        if the Pre-Amp bias is too high 
        <Condtype> CLIENT_BIAS_HIGH_WARNING 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmclientEdfaWarnings 8 }



pmoabphcAlmClientBiasLowWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Bias Low Warning :This 
        OID indicates that the Bias is
         lower than the Warning theshold 
        of the Pre-Amp Optical Module 
         <Help>  This warning indicates 
        if the Pre-Amp bias is too low
         <Condtype> CLIENT_BIAS_LOW_WARNING 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmclientEdfaWarnings 7 }



pmoabphcAlmClientOutputPwrHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Tx Pwr High Warning :This 
        OID indicates that the Transmit 
        Power is higher than the Warning 
        theshold of the Pre-Amp Optical 
        Module  <Help>  This warning indicates 
        if the Pre-Amp tx power is too
         high <Condtype> CLIENT_OUTPUT_PWR_HIGH_WARNING 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmclientEdfaWarnings 6 }



pmoabphcAlmClientOutputPwrLowWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Tx Pwr Low Warning :This 
        OID indicates that the Transmit 
        Power is lower than the Warning 
        theshold of the Pre-Amp Optical 
        Module  <Help>  This warning indicates 
        if the Pre-Amp tx power is too
         low <Condtype> CLIENT_OUTPUT_PWR_LOW_WARNING 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmclientEdfaWarnings 5 }



pmoabphcAlmClientInputPwrHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Rx Pwr High Warning :This 
        OID indicates that the Receive
         Power is higher than the Warning 
        theshold of the Booster Optical 
        Module  <Help>  This warning indicates 
        if the Booster rx power is too
         high <Condtype> CLIENT_INPUT_PWR_HIGH_WARNING 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmoabphcAlmclientEdfaWarnings 4 }



pmoabphcAlmClientInputPwrLowWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Rx Pwr Low Warning :This 
        OID indicates that the Receive
         Power is lower than the Warning 
        theshold of the Booster Optical 
        Module  <Help>  This warning indicates 
        if the Booster rx power is too
         low <Condtype> CLIENT_INPUT_PWR_LOW_WARNING 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmoabphcAlmclientEdfaWarnings 3 }



pmoabphcAlmClientGainHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Gain High Warning :This 
        OID indicates that the Gain is
         higher than the Warning threshold 
        of the Pre-Amp Module  <Help> 
         This alarm indicates if the Pre-Amp 
        gain is too high <Condtype> CLIENT_GAIN_HIGH_WARNING 
        <Probcause> performanceDegraded 
        (35) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmclientEdfaWarnings 2 }



pmoabphcAlmClientGainLowWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Gain Low Warning :This 
        OID indicates that the Gain is
         lower than the Warning theshold 
        of the Pre-Amp Module  <Help> 
         This alarm indicates if the Pre-Amp 
        gain is too low <Condtype> CLIENT_GAIN_LOW_WARNING 
        <Probcause> performanceDegraded 
        (35) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmclientEdfaWarnings 1 }



--- *****************************************************
---     LEAF for the clientEdfaAlarms2 article
--- *****************************************************
pmoabphcAlmclientEdfaAlarms2 OBJECT IDENTIFIER ::= { pmoabphcAlmClientCrit 35 }




pmoabphcAlmClientExtPumpEdfaLowCurrent OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Pump Low Current :This 
        OID indicates that the EDFA pump 
        current of Pre-Amp is too low because 
        of the external pump high power<Help> 
         This alarm (only active when there 
        is at least on external pump) indicates 
        that the EDFA pump current of the 
        Pre-Amp is too low because of the 
        external pump high power. <Condtype> 
        CLIENT_EXT_PUMP_EDFA_LOW_CURRENT 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5)  <Polarity>
         (2) 
        "
	  ::= { pmoabphcAlmclientEdfaAlarms2 5 }



pmoabphcAlmClientEdfaLos OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Loss Of Signal :This OID 
        indicates a Loss of Signal on the 
        Booster Optical Module  <Help>
          This alarm indicates if an optical 
        signal is detected on the Booster 
        input <Condtype> CLIENT_EDFA_LOS 
        <Probcause> receiveFailure (41) 
        <Alarmtype> physicalViolation (9) 
        <Polarity> (2) 
        "
	  ::= { pmoabphcAlmclientEdfaAlarms2 4 }



pmoabphcAlmClientEdfaLaserFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Pump Laser Fail :This
         OID indicates a Transmit Laser 
        Fail on the Pre-Amp Optical Module 
         <Help>  This alarm indicates if 
        the laser of the Pre-Amp is in
         fail condition <Condtype> CLIENT_EDFA_LASER_FAIL 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmclientEdfaAlarms2 3 }



pmoabphcAlmClientEdfaTecFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp TEC Fail :This OID indicates 
        that the TEC is in fail condition 
        on the Pre-Amp Optical Module 
         <Help>  This alarm indicates if 
        the TEC of the Pre-Amp is in fail 
        condition <Condtype> CLIENT_EDFA_TEC_FAIL 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmclientEdfaAlarms2 2 }



pmoabphcAlmClientEdfaNr OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Optical Module Not Ready 
        :This OID indicates that the Pre-Amp 
        Optical Module is not ready  <Help> 
         This status indicates if the Pre-Amp 
        has been correctly initialized
         <Condtype> CLIENT_EDFA_NR <Probcause> 
        equipmentMalfunction (16) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmclientEdfaAlarms2 1 }



--- *****************************************************
---     LEAF for the lineEdfaAlarms1 article
--- *****************************************************
pmoabphcAlmlineEdfaAlarms1 OBJECT IDENTIFIER ::= { pmoabphcAlmLineUrg 40 }




pmoabphcAlmLineBiasHighAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Bias High Alarm :This
         OID indicates that the Bias is 
        higher than the alarm theshold
         of the Booster Optical Module
          <Help>  This alarm indicates
         if the Booster bias is too high 
        <Condtype> LINE_BIAS_HIGH_ALARM 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmlineEdfaAlarms1 8 }



pmoabphcAlmLineBiasLowAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Bias Low Alarm :This OID 
        indicates that the Bias is lower 
        than the alarm theshold of the
         Booster Optical Module  <Help> 
         This alarm indicates if the Booster 
        bias is too low <Condtype> LINE_BIAS_LOW_ALARM 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmlineEdfaAlarms1 7 }



pmoabphcAlmLineOutputPwrHighAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Tx Pwr High Alarm :This 
        OID indicates that the Transmit 
        Power is higher than the alarm
         theshold of the Booster Optical 
        Module  <Help>  This alarm indicates 
        if the Booster tx power is too
         high <Condtype> LINE_OUTPUT_PWR_HIGH_ALARM 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmlineEdfaAlarms1 6 }



pmoabphcAlmLineOutputPwrLowAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Tx Pwr Low Alarm :This 
        OID indicates that the Transmit 
        Power is lower than the alarm theshold 
        of the Booster Optical Module 
         <Help>  This alarm indicates if 
        the Booster tx power is too low 
        <Condtype> LINE_OUTPUT_PWR_LOW_ALARM 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmlineEdfaAlarms1 5 }



pmoabphcAlmLineInputPwrHighAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Rx Pwr High Alarm :This 
        OID indicates that the Receive
         Power is higher than the alarm 
        theshold of the Pre-Amp Optical 
        Module  <Help>  This alarm indicates 
        if the Pre-Amp rx power is too
         high <Condtype> LINE_INPUT_PWR_HIGH_ALARM 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmoabphcAlmlineEdfaAlarms1 4 }



pmoabphcAlmLineInputPwrLowAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Rx Pwr Low Alarm :This 
        OID indicates that the Receive
         Power is lower than the alarm
         theshold of the Pre-Amp Optical 
        Module  <Help>  This alarm indicates 
        if the Pre-Amp rx power is too
         low <Condtype> LINE_INPUT_PWR_LOW_ALARM 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmoabphcAlmlineEdfaAlarms1 3 }



pmoabphcAlmLineGainHighAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Gain High Alarm :This
         OID indicates that the Gain is 
        higher than the alarm threshold 
        of the Booster Module  <Help> 
         This alarm indicates if the Booster 
        gain is too high <Condtype> LINE_GAIN_HIGH_ALARM 
        <Probcause> performanceDegraded 
        (35) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmlineEdfaAlarms1 2 }



pmoabphcAlmLineGainLowAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Gain Low Alarm :This OID 
        indicates that the Gain is lower 
        than the alarm theshold of the
         Booster Module  <Help>  This alarm 
        indicates if the Booster gain is 
        too low <Condtype> LINE_GAIN_LOW_ALARM 
        <Probcause> performanceDegraded 
        (35) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmlineEdfaAlarms1 1 }



--- *****************************************************
---     LEAF for the lineEdfaWarnings article
--- *****************************************************
pmoabphcAlmlineEdfaWarnings OBJECT IDENTIFIER ::= { pmoabphcAlmLineNurg 41 }




pmoabphcAlmLineBiasHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Bias High Warning :This 
        OID indicates that the Bias is
         higher than the Warning theshold 
        of the Booster Optical Module 
         <Help>  This warning indicates 
        if the Booster bias is too high 
        <Condtype> LINE_BIAS_HIGH_WARNING 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmlineEdfaWarnings 8 }



pmoabphcAlmLineBiasLowWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Bias Low Warning :This 
        OID indicates that the Bias is
         lower than the Warning theshold 
        of the Booster Optical Module 
         <Help>  This warning indicates 
        if the Booster bias is too low
         <Condtype> LINE_BIAS_LOW_WARNING 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmlineEdfaWarnings 7 }



pmoabphcAlmLineOutputPwrHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Tx Pwr High Warning :This 
        OID indicates that the Transmit 
        Power is higher than the Warning 
        theshold of the Booster Optical 
        Module  <Help>  This warning indicates 
        if the Booster tx power is too
         high <Condtype> LINE_OUTPUT_PWR_HIGH_WARNING 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmlineEdfaWarnings 6 }



pmoabphcAlmLineOutputPwrLowWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Tx Pwr Low Warning :This 
        OID indicates that the Transmit 
        Power is lower than the Warning 
        theshold of the Booster Optical 
        Module  <Help>  This warning indicates 
        if the Booster tx power is too
         low <Condtype> LINE_OUTPUT_PWR_LOW_WARNING 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmlineEdfaWarnings 5 }



pmoabphcAlmLineInputPwrHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Rx Pwr High Warning :This 
        OID indicates that the Receive
         Power is higher than the Warning 
        theshold of the Pre-Amp Optical 
        Module  <Help>  This warning indicates 
        if the Pre-Amp rx power is too
         high <Condtype> LINE_INPUT_PWR_HIGH_WARNING 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmoabphcAlmlineEdfaWarnings 4 }



pmoabphcAlmLineInputPwrLowWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Rx Pwr Low Warning :This 
        OID indicates that the Receive
         Power is lower than the Warning 
        theshold of the Pre-Amp Optical 
        Module  <Help>  This warning indicates 
        if the Pre-Amp rx power is too
         low <Condtype> LINE_INPUT_PWR_LOW_WARNING 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmoabphcAlmlineEdfaWarnings 3 }



pmoabphcAlmLineGainHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Gain High Warning :This 
        OID indicates that the Gain is
         higher than the Warning threshold 
        of the Booster Module  <Help> 
         This alarm indicates if the Booster 
        gain is too high <Condtype> LINE_GAIN_HIGH_WARNING 
        <Probcause> performanceDegraded 
        (35) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmlineEdfaWarnings 2 }



pmoabphcAlmLineGainLowWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Gain Low Warning :This 
        OID indicates that the Gain is
         lower than the Warning theshold 
        of the Booster Module  <Help> 
         This alarm indicates if the Booster 
        gain is too low <Condtype> LINE_GAIN_LOW_WARNING 
        <Probcause> performanceDegraded 
        (35) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmlineEdfaWarnings 1 }



--- *****************************************************
---     LEAF for the lineEdfaAlarms2 article
--- *****************************************************
pmoabphcAlmlineEdfaAlarms2 OBJECT IDENTIFIER ::= { pmoabphcAlmLineCrit 43 }




pmoabphcAlmLineExtPumpEdfaLowCurrent OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Pump Low Current :This 
        OID indicates that the EDFA pump 
        current of Booster is too low because 
        of the external pump high power<Help> 
         This alarm (only active when there 
        is at least on external pump) indicates 
        that the EDFA pump current of the 
        Booster is too low because of the 
        external pump high power. <Condtype> 
        LINE_EXT_PUMP_EDFA_LOW_CURRENT
         <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5)  <Polarity>
         (2) 
        "
	  ::= { pmoabphcAlmlineEdfaAlarms2 5 }



pmoabphcAlmLineEdfaLos OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Loss Of Signal :This OID 
        indicates a Loss of Signal on the 
        Pre-Amp Optical Module  <Help>
          This alarm indicates if an optical 
        signal is detected on the Pre-Amp 
        input <Condtype> LINE_EDFA_LOS
         <Probcause> receiveFailure (41) 
        <Alarmtype> physicalViolation (9) 
        <Polarity> (2) 
        "
	  ::= { pmoabphcAlmlineEdfaAlarms2 4 }



pmoabphcAlmLineEdfaLaserFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Pump Laser Fail :This
         OID indicates a Transmit Laser 
        Fail on the Booster Optical Module 
         <Help>  This alarm indicates if 
        the laser of the Booster is in
         fail condition <Condtype> LINE_EDFA_LASER_FAIL 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmlineEdfaAlarms2 3 }



pmoabphcAlmLineEdfaTecFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster TEC Fail :This OID indicates 
        that the TEC is in fail condition 
        on the Booster Optical Module 
         <Help>  This alarm indicates if 
        the TEC of the Booster is in fail 
        condition <Condtype> LINE_EDFA_TEC_FAIL 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmlineEdfaAlarms2 2 }



pmoabphcAlmLineEdfaNr OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Optical Module Not Ready 
        :This OID indicates that the Booster 
        Optical Module is not ready  <Help> 
         This status indicates if the Booster 
        has been correctly initialized
         <Condtype> LINE_EDFA_NR <Probcause> 
        equipmentMalfunction (16) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmlineEdfaAlarms2 1 }



--- *****************************************************
---     LEAF for the foaAlarms article
--- *****************************************************
pmoabphcAlmfoaAlarms OBJECT IDENTIFIER ::= { pmoabphcAlmOtherUrg 74 }




pmoabphcAlmTempHighAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Temperature High Alarm :This OID 
        indicates that the PM temperature 
        is higher than the alarm threshold 
        <Condtype> TEMP_HIGH_ALARM <Probcause> 
        temperatureUnacceptable (51) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmfoaAlarms 8 }



pmoabphcAlmTermpLowAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Temperature Low Alarm :This OID 
        indicates that the PM temperature 
        if lower than the alarm threshold 
        <Condtype> TERMP_LOW_ALARM <Probcause> 
        temperatureUnacceptable (51) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmfoaAlarms 7 }



--- *****************************************************
---     LEAF for the foaWarnings article
--- *****************************************************
pmoabphcAlmfoaWarnings OBJECT IDENTIFIER ::= { pmoabphcAlmOtherNurg 75 }




pmoabphcAlmTempHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Temperature High Warning :This 
        OID indicates that the PM temperature 
        if higher than the Warning threshold 
        <Condtype> TEMP_HIGH_WARNING <Probcause> 
        temperatureUnacceptable (51) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmfoaWarnings 8 }



pmoabphcAlmTermpLowWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Temperature Low Warning :This
         OID indicates that the PM temperature 
        if lower than the Warning threshold 
        <Condtype> TERMP_LOW_WARNING <Probcause> 
        temperatureUnacceptable (51) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoabphcAlmfoaWarnings 7 }








--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     CONTROLS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the synth0 article
--- *****************************************************
pmoabphcCtrlsynth0 OBJECT IDENTIFIER ::= { pmoabphcCtrlOther 0 }




pmoabphcCtrlConfClear OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Clear Configuration Tables :This 
        bit clears the configuration tables 
        from configuration in the flash. 
         <Help>  This control restores
         the default configuration of the 
        module
        "
	  ::= { pmoabphcCtrlsynth0 13 }



pmoabphcCtrlConfFlash OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Write Configuration Tables :This 
        bit saves the current configuration 
        of the module as configuration
         in the flash.  <Help>  This control 
        saves the customer configuration 
        on the module
        "
	  ::= { pmoabphcCtrlsynth0 9 }



pmoabphcCtrlConfLoad OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Load Configuration Tables :When 
        set this enables loading from flash 
        configuration1 into the module.
        "
	  ::= { pmoabphcCtrlsynth0 1 }



--- *****************************************************
---     LEAF for the swMgnt article
--- *****************************************************
pmoabphcCtrlswMgnt OBJECT IDENTIFIER ::= { pmoabphcCtrlOther 5 }




pmoabphcCtrlWarmReset OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        PM Warm Reset :This OID, when
         set, causes a warm reset of the 
        Software. This reset is not traffic 
        affecting, and the configuration 
        of the Sofwtare remains unchanged. 
         <Help>  This control initiates 
        a warm reset of the module.
        "
	  ::= { pmoabphcCtrlswMgnt 3 }



pmoabphcCtrlColdReset OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        PM Cold Reset :This OID, when
         set, causes a cold reset of the 
        Software. This reset is traffic 
        affecting, and the configuration 
        of Software is reloaded on start-up. 
         <Help>  This control initiates 
        a cold reset of the module.
        "
	  ::= { pmoabphcCtrlswMgnt 2 }



--- *****************************************************
---     LEAF for the clientEdfaLaserOff article
--- *****************************************************
pmoabphcCtrlclientEdfaLaserOff OBJECT IDENTIFIER ::= { pmoabphcCtrlClient 32 }




pmoabphcCtrlClientEdfaLaserOff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Optical Module Laser Off 
        :This OID switches OFF the laser 
        of the Pre-Amp Optical Module 
         <Help>  This control defines the 
        laser state of the Pre-Amp
        "
	  ::= { pmoabphcCtrlclientEdfaLaserOff 1 }



--- *****************************************************
---     LEAF for the clientGainCstMonitorValue article
--- *****************************************************

pmoabphcCtrlclientGainCstMonitorValue OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Fiber Aging Period :This 
        OID sets the value of the monitoring 
        period to detect a fiber aging. 
        (Unit = s) This value sets the
         monitoring period to detect a
         fiber aging.
        "
	  ::= { pmoabphcCtrlClient 34 }



--- *****************************************************
---     LEAF for the clientGainCstPoutValue article
--- *****************************************************

pmoabphcCtrlclientGainCstPoutValue OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Ref Pout :This OID sets 
        the value of the reference output 
        power used to compensate the fiber 
        aging  (active only in constant 
        gain mode) (AV=(Gain/0,005) + 32768) 
        (Unit = dBm) <Help> This value
         defines the reference output power 
        used to compensate the fiber aging
        "
	  ::= { pmoabphcCtrlClient 35 }



--- *****************************************************
---     LEAF for the clientGainSettingValue article
--- *****************************************************

pmoabphcCtrlclientGainSettingValue OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Gain Target :This OID
         sets the value of the nominal
         gain of the Pre-Amplifier Module 
        (active only in constant output 
        power mode) (AV=(Gain/0,005) +
         32768) (Unit = dB)<Help> This
         control sets the value of the
         nominal gain of the Pre- Amplifier 
        Module (active only in constant 
        output power mode)
        "
	  ::= { pmoabphcCtrlClient 36 }



--- *****************************************************
---     LEAF for the clientGainProcessing article
--- *****************************************************
pmoabphcCtrlclientGainProcessing OBJECT IDENTIFIER ::= { pmoabphcCtrlClient 37 }




pmoabphcCtrlClientGainProc OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Gain Adjustment :This
         OID initiates the automatic nominal 
        gain adjustment on the Pre-Amplifier 
        Module<Help> This control initiates 
        the automatic nominal gain adjustment 
        on the Pre-Amplifier Module
        "
	  ::= { pmoabphcCtrlclientGainProcessing 1 }



--- *****************************************************
---     LEAF for the clientGainCstFiberAgingMarginValue article
--- *****************************************************

pmoabphcCtrlclientGainCstFiberAgingMarginValue OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Aging Threshold :This
         OID sets the threshold to consider 
        the power drop as a fiber aging. 
        (active only in constant gain mode) 
        (AV=(Gain/0,005) + 32768) (Unit 
        = dB) <Help> This value defines 
        the threshold to consider the power 
        drop as a fiber aging.
        "
	  ::= { pmoabphcCtrlClient 38 }



--- *****************************************************
---     LEAF for the clientGainCstAdddropMarginValue article
--- *****************************************************

pmoabphcCtrlclientGainCstAdddropMarginValue OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp AddDrop Threshold :This 
        OID sets the threshold to not consider 
        the power drop as a fiber aging. 
         (active only in constant gain
         mode) (AV=(Gain/0,005) + 32768) 
        (Unit = dB) <Help> This value defines 
        the threshold to not consider the 
        power drop as a fiber aging.
        "
	  ::= { pmoabphcCtrlClient 39 }



--- *****************************************************
---     LEAF for the lineEdfaLaserOff article
--- *****************************************************
pmoabphcCtrllineEdfaLaserOff OBJECT IDENTIFIER ::= { pmoabphcCtrlLine 40 }




pmoabphcCtrlLineEdfaLaserOff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Booster Optical Module Laser Off 
        :This OID switches OFF the laser 
        of the Booster Optical Module 
         <Help>  This control defines the 
        laser state of the Booster
        "
	  ::= { pmoabphcCtrllineEdfaLaserOff 1 }



--- *****************************************************
---     LEAF for the lineGainCstMonitorValue article
--- *****************************************************

pmoabphcCtrllineGainCstMonitorValue OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Booster Fiber Aging Period :This 
        OID sets the value of the monitoring 
        period to detect a fiber aging. 
        (Unit = s) This value sets the
         monitoring period to detect a
         fiber aging.
        "
	  ::= { pmoabphcCtrlLine 42 }



--- *****************************************************
---     LEAF for the lineGainCstPoutValue article
--- *****************************************************

pmoabphcCtrllineGainCstPoutValue OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Booster Ref Pout :This OID sets 
        the value of the reference output 
        power used to compensate the fiber 
        aging  (active only in constant 
        gain mode) (AV=(Gain/0,005) + 32768) 
        (Unit = dBm) <Help> This value
         defines the reference output power 
        used to compensate the fiber aging
        "
	  ::= { pmoabphcCtrlLine 43 }



--- *****************************************************
---     LEAF for the lineGainSettingValue article
--- *****************************************************

pmoabphcCtrllineGainSettingValue OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Booster Gain Target :This OID
         sets the value of the nominal
         gain of the Booster Module (active 
        only in constant output power mode) 
        (AV=(Gain/0,005) + 32768) (Unit 
        = dB) <Help> This control sets
         the value of the nominal gain
         of the Booster Module (active
         only in constant output power
         mode)
        "
	  ::= { pmoabphcCtrlLine 44 }



--- *****************************************************
---     LEAF for the lineGainProcessing article
--- *****************************************************
pmoabphcCtrllineGainProcessing OBJECT IDENTIFIER ::= { pmoabphcCtrlLine 45 }




pmoabphcCtrlLineGainProc OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Booster Gain Adjustment :This
         OID initiates the automatic nominal 
        gain adjustment on the Booster
         Module<Help> This control initiates 
        the automatic nominal gain adjustment 
        on the Booster Module
        "
	  ::= { pmoabphcCtrllineGainProcessing 1 }



--- *****************************************************
---     LEAF for the lineGainCstFiberAgingMarginValue article
--- *****************************************************

pmoabphcCtrllineGainCstFiberAgingMarginValue OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Booster Aging Threshold :This
         OID sets the threshold to consider 
        the power drop as a fiber aging. 
        (active only in constant gain mode) 
        (AV=(Gain/0,005) + 32768) (Unit 
        = dB) <Help> This value defines 
        the threshold to consider the power 
        drop as a fiber aging.
        "
	  ::= { pmoabphcCtrlLine 46 }



--- *****************************************************
---     LEAF for the lineGainCstAdddropMarginValue article
--- *****************************************************

pmoabphcCtrllineGainCstAdddropMarginValue OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Booster AddDrop Threshold :This 
        OID sets the threshold to not consider 
        the power drop as a fiber aging. 
         (active only in constant gain
         mode) (AV=(Gain/0,005) + 32768) 
        (Unit = dB) <Help> This value defines 
        the threshold to not consider the 
        power drop as a fiber aging.
        "
	  ::= { pmoabphcCtrlLine 47 }



--- *****************************************************
---     LEAF for the ledTest article
--- *****************************************************
pmoabphcCtrlledTest OBJECT IDENTIFIER ::= { pmoabphcCtrlOther 73 }




pmoabphcCtrlLedOff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Leds Off :This OID switches off 
        all the Leds as a test feature. 
         <Help>  This control initiates 
        a test leds turning all the LEDs 
        to OFF
        "
	  ::= { pmoabphcCtrlledTest 3 }



pmoabphcCtrlRedLed OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Red Leds Test :This OID switches 
        on all the red Leds as a test feature. 
         <Help>  This control initiates 
        a test leds turning all the LEDs 
        to red
        "
	  ::= { pmoabphcCtrlledTest 2 }



pmoabphcCtrlGreenLed OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Green Leds Test :This OID switches 
        on all the green Leds as a test 
        feature.  <Help>  This control
         initiates a test leds turning
         all the LEDs to green
        "
	  ::= { pmoabphcCtrlledTest 1 }



--- *****************************************************
---     LEAF for the maintMode article
--- *****************************************************
pmoabphcCtrlmaintMode OBJECT IDENTIFIER ::= { pmoabphcCtrlOther 75 }




pmoabphcCtrlMaintenance OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        PM Maintenance Mode :This OID
         sets the PM in maintenance mode 
         <Help>  This control enables the 
        maintenance mode of the module
        "
	  ::= { pmoabphcCtrlmaintMode 1 }



--- *****************************************************
---     LEAF for the aprRestart article
--- *****************************************************
pmoabphcCtrlaprRestart OBJECT IDENTIFIER ::= { pmoabphcCtrlOther 76 }




pmoabphcCtrlAprManualRestart OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        APR Manual Restart :This OID initiates 
        the Restart mechanism to retrieve 
        from the APR state.<Help> This
         control initiates the Restart
         mechanism to retrieve from the 
        APR state.
        "
	  ::= { pmoabphcCtrlaprRestart 1 }








--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     MEASURES
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the clientEdfaBiasMeas article
--- *****************************************************

pmoabphcMesrclientEdfaBiasMeas OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Pump Laser Current :This 
        OID gives the pump laser current 
        of the Pre-Amp Optical Module (Current 
        =AV/100) (Unit = mA)  <Help>  This 
        measure gives the bias of the Pre-Amp 
        pump laser
        "
	  ::= { pmoabphcMesrClient 32 }



--- *****************************************************
---     LEAF for the clientEdfaTxpwrMeas article
--- *****************************************************

pmoabphcMesrclientEdfaTxpwrMeas OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Tx Power :This OID gives 
        the transmit power value of the 
        Pre-Amp Optical Module (Power =(AV-32768)*0,005) 
         (Unit = dBm)  <Help>  This measure 
        gives the Tx optical power of the 
        Pre-Amp
        "
	  ::= { pmoabphcMesrClient 33 }



--- *****************************************************
---     LEAF for the clientEdfaRxpwrMeas article
--- *****************************************************

pmoabphcMesrclientEdfaRxpwrMeas OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Rx Power :This OID gives 
        the receive power value of the
         Booster Optical Module (Power
         =(AV-32768)*0,005) (Unit = dBm) 
         <Help>  This measure gives the 
        Rx optical power of the Booster
        "
	  ::= { pmoabphcMesrClient 34 }



--- *****************************************************
---     LEAF for the clientEdfaGainMeas article
--- *****************************************************

pmoabphcMesrclientEdfaGainMeas OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Gain Target :This OID
         gives the gain value of the Pre-Amp 
        Module  (Gain =(AV-32768)*0,005) 
        (Unit = dB)  <Help> This information 
        gives the target gain of the amplifier 
        for optimal performance
        "
	  ::= { pmoabphcMesrClient 35 }



--- *****************************************************
---     LEAF for the clientCorrectedGain article
--- *****************************************************

pmoabphcMesrclientCorrectedGain OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Gain :This OID gives the 
        gain value of the Pre-Amp Module 
        corrected by the ASE compensation 
        mechanism (Gain =(AV-32768)*0,005) 
        (Unit = dB)   <Help>  This measure 
        gives the effective gain of the 
        amplifier
        "
	  ::= { pmoabphcMesrClient 38 }



--- *****************************************************
---     LEAF for the lineEdfaBiasMeas article
--- *****************************************************

pmoabphcMesrlineEdfaBiasMeas OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Pump Laser Current :This 
        OID gives the pump laser current 
        of the Booster Optical Module 
         (Current =AV/100) (Unit = mA)
          <Help>  This measure gives the 
        bias of the Booster pump laser
        "
	  ::= { pmoabphcMesrLine 40 }



--- *****************************************************
---     LEAF for the lineEdfaTxpwrMeas article
--- *****************************************************

pmoabphcMesrlineEdfaTxpwrMeas OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Tx Power :This OID gives 
        the transmit power value of the 
        Booster Optical Module (Power =(AV-32768)*0,005) 
        (Unit = dBm)  <Help>  This measure 
        gives the Tx optical power of the 
        Booster
        "
	  ::= { pmoabphcMesrLine 41 }



--- *****************************************************
---     LEAF for the lineEdfaRxpwrMeas article
--- *****************************************************

pmoabphcMesrlineEdfaRxpwrMeas OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Rx Power :This OID gives 
        the receive power value of the
         Pre-Amp Optical Module (Power
         =(AV-32768)*0,005) (Unit = dBm) 
         <Help>  This measure gives the 
        Rx optical power of the Pre-Amp
        "
	  ::= { pmoabphcMesrLine 42 }



--- *****************************************************
---     LEAF for the lineEdfaGainMeas article
--- *****************************************************

pmoabphcMesrlineEdfaGainMeas OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Gain Target :This OID
         gives the gain value of the Booster 
        Module  (Gain =(AV-32768)*0,005) 
        (Unit = dB)  <Help>  This information 
        gives the target gain of the amplifier 
        for optimal performance
        "
	  ::= { pmoabphcMesrLine 43 }



--- *****************************************************
---     LEAF for the lineCorrectedGain article
--- *****************************************************

pmoabphcMesrlineCorrectedGain OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Gain :This OID gives the 
        gain value of the Booster Module 
        corrected by the ASE compensation 
        mechanism (Gain =(AV-32768)*0,005) 
        (Unit = dB)   <Help>  This measure 
        gives the effective gain of the 
        amplifier
        "
	  ::= { pmoabphcMesrLine 46 }



--- *****************************************************
---     LEAF for the tempMeas article
--- *****************************************************

pmoabphcMesrtempMeas OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Module Temperature :This OID gives 
        the temperature of the PM  (Temperature 
        =AV/256) (Unit = C)  <Help>  This 
        measure gives the temperature of 
        the module
        "
	  ::= { pmoabphcMesrOther 72 }








--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     CONFIG
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the table Group noValue
--- *****************************************************

pmoabphcCfgNoValue OBJECT IDENTIFIER ::= { pmoabphcConfig 1 }



--- *****************************************************
---     LEAF for the table 2111
--- *****************************************************

pmoabphctableclientStartup OBJECT IDENTIFIER ::= { pmoabphcCfgNoValue 1 }



pmoabphcCfgclientEdfaLaserCtrl OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Client Laser 
        :This OID configures the default 
        initialisation settings on the
         client laser.
        "
	  ::= { pmoabphctableclientStartup 2 }



pmoabphcCfgclientEdfaLaserMode OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Client mode 
        :This OID configures the default 
        mode on the client amplifier.
        "
	  ::= { pmoabphctableclientStartup 3 }



pmoabphcCfgclientGainValue OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Client Gain 
        :This OID configures the default 
        gain on the client amplifier.
        "
	  ::= { pmoabphctableclientStartup 4 }



pmoabphcCfgclientTiltValue OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Client Tilt 
        :This OID configures the default 
        tilt on the client amplifier.
        "
	  ::= { pmoabphctableclientStartup 5 }



pmoabphcCfgclientMsaLoss OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Client MSA 
        :This OID configures the default 
        MSA value on the client amplifier.
        "
	  ::= { pmoabphctableclientStartup 6 }



pmoabphcCfgclientOutputPowerValue OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Client Output 
        power :This OID configures the
         default Output power value on
         the client amplifier.
        "
	  ::= { pmoabphctableclientStartup 7 }



pmoabphcCfgclientAseCompensation OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Client ASE 
        :This OID configures the default 
        ASE compensation value on the client 
        amplifier.
        "
	  ::= { pmoabphctableclientStartup 8 }



--- *****************************************************
---     LEAF for the table Group lineStartUp
--- *****************************************************

pmoabphcCfgLineStartUp OBJECT IDENTIFIER ::= { pmoabphcConfig 2 }



--- *****************************************************
---     LEAF for the table 2191
--- *****************************************************

pmoabphctablelineStartup OBJECT IDENTIFIER ::= { pmoabphcCfgLineStartUp 1 }



pmoabphcCfglineEdfaLaserCtrl OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Line Laser 
        :This OID configures the default 
        initialisation settings on the
         line laser.
        "
	  ::= { pmoabphctablelineStartup 2 }



pmoabphcCfglineEdfaLaserMode OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Line mode
         :This OID configures the default 
        mode on the line amplifier.
        "
	  ::= { pmoabphctablelineStartup 3 }



pmoabphcCfglineGainValue OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Line Gain
         :This OID configures the default 
        gain on the line amplifier.
        "
	  ::= { pmoabphctablelineStartup 4 }



pmoabphcCfglineTiltValue OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Line Tilt
         :This OID configures the default 
        tilt on the line amplifier.
        "
	  ::= { pmoabphctablelineStartup 5 }



pmoabphcCfglineMsaLoss OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Line MSA :This 
        OID configures the default MSA
         value on the line amplifier.
        "
	  ::= { pmoabphctablelineStartup 6 }



pmoabphcCfglineOutputPowerValue OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Line Output 
        power :This OID configures the
         default Output power value on
         the line amplifier.
        "
	  ::= { pmoabphctablelineStartup 7 }



pmoabphcCfglineAseCompensation OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Line ASE :This 
        OID configures the default ASE
         compensation value on the line 
        amplifier.
        "
	  ::= { pmoabphctablelineStartup 8 }



pmoabphcCfgaprMode OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default setting on module :This 
        OID configures the default mode 
        on the APR
        "
	  ::= { pmoabphctablelineStartup 11 }



--- *****************************************************
---     LEAF for the table Group labels
--- *****************************************************

pmoabphcCfgLabels OBJECT IDENTIFIER ::= { pmoabphcConfig 3 }



--- *****************************************************
---     LEAF for the table NO_VALUE
--- *****************************************************

pmoabphcCfgLabelclientTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PmoabphcCfgLabelclientEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pmoabphcCfgLabels 1 }


pmoabphcCfgLabelclientEntry OBJECT-TYPE
	SYNTAX PmoabphcCfgLabelclientEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the labels
         table
        "
	INDEX   { pmoabphcCfgLabelclientIndex }
	::= { pmoabphcCfgLabelclientTable 1 }


PmoabphcCfgLabelclientEntry ::=
	SEQUENCE {
	pmoabphcCfgLabelclientIndex
		INTEGER,
	pmoabphcCfgLabelclientPortn
		DisplayString
	}


pmoabphcCfgLabelclientIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the labelclient 
        table
        "
	::= { pmoabphcCfgLabelclientEntry 1 }


pmoabphcCfgLabelclientPortn OBJECT-TYPE
	SYNTAX  DisplayString( SIZE(1..16))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default settings on the label
         of the Ports :These registers
         configures the default initialisation 
        settings of the labels of the ports.
        "
	::= { pmoabphcCfgLabelclientEntry 3 }


--- *****************************************************
---     LEAF for the table NO_VALUE
--- *****************************************************

pmoabphcCfgLabellineTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PmoabphcCfgLabellineEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pmoabphcCfgLabels 2 }


pmoabphcCfgLabellineEntry OBJECT-TYPE
	SYNTAX PmoabphcCfgLabellineEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the labels
         table
        "
	INDEX   { pmoabphcCfgLabellineIndex }
	::= { pmoabphcCfgLabellineTable 1 }


PmoabphcCfgLabellineEntry ::=
	SEQUENCE {
	pmoabphcCfgLabellineIndex
		INTEGER,
	pmoabphcCfgLabellinePortn
		DisplayString
	}


pmoabphcCfgLabellineIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the labelline 
        table
        "
	::= { pmoabphcCfgLabellineEntry 1 }


pmoabphcCfgLabellinePortn OBJECT-TYPE
	SYNTAX  DisplayString( SIZE(1..16))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default settings on the label
         of the lines :These registers
         configures the default initialisation 
        settings of the labels of the lines.
        "
	::= { pmoabphcCfgLabellineEntry 3 }



pmoabphcCfgWriteConfiguration  OBJECT-TYPE
	SYNTAX EkiOnOff
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
	"Write configuration to module:This OID 
	 writes the complete configuration to the module"
	::= { pmoabphcConfig 257 }






--- *****************************************************
---     TRAP OBJECTS
--- *****************************************************

pmoabphctrapBoardNumber OBJECT-TYPE
	SYNTAX INTEGER(1..64)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
	"Last module which generates a trap"
	::= { pmoabphctraps 4 }







--- *****************************************************
---     GLOBAL TRAPS
--- *****************************************************

pmoabphcLineTrapNotUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pmoabphcAlmLineDdmWarning, pmoabphctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOABPHC Line Not Urgent ON"
	--&ACTIONS     { log, minor }
	--&MATCH       { pmoabphcAlmLineDdmWarning "on", pmoabphctrapBoardNumber "$2"}
	--&MESG        "DDM Warning appears on Pre-Amp input or Booster Output of PMOABPHC in slot $2 ($A)"
	DESCRIPTION "Not urgent Line default is activated"
	::= { pmoabphctraps 30 }

pmoabphcLineTrapNotUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pmoabphcAlmLineDdmWarning, pmoabphctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOABPHC Line Not Urgent OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      {"PMOABPHC Line Not Urgent ON"}
	--&MATCH       { pmoabphcAlmLineDdmWarning "on", pmoabphctrapBoardNumber "$2"}
	--&MESG        "DDM Warning disappears on Pre-Amp input or Booster Output of PMOABPHC in slot $2 ($A)"
	DESCRIPTION "Not urgent Line default disappeared"
	::= { pmoabphctraps 31 }

pmoabphcLineTrapUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pmoabphcAlmLineDdmAlm, pmoabphctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOABPHC Line Urgent ON"
	--&ACTIONS     { log, major }
	--&MATCH       { pmoabphcAlmLineDdmAlm "on", pmoabphctrapBoardNumber "$2"}
	--&MESG        "DDM Alarm appears on Pre-Amp input or Booster Output of PMOABPHC in slot $2 ($A)"
	DESCRIPTION "Urgent Line default is activated"
	::= { pmoabphctraps 32 }

pmoabphcLineTrapUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pmoabphcAlmLineDdmAlm, pmoabphctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOABPHC Line Urgent OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      {"PMOABPHC Line Urgent ON"}
	--&MATCH       { pmoabphcAlmLineDdmAlm "on", pmoabphctrapBoardNumber "$2"}
	--&MESG        "DDM Alarm disappears on Pre-Amp input or Booster Output of PMOABPHC in slot $2 ($A)"
	DESCRIPTION "Urgent Line default disappeared"
	::= { pmoabphctraps 33 }

pmoabphcLineTrapCritGoesOn NOTIFICATION-TYPE
	OBJECTS {pmoabphcAlmLineFail, pmoabphcAlmLineHwFail, pmoabphctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOABPHC Line Fail ON"
	--&ACTIONS     { log, critical }
	--&MATCH       { pmoabphcAlmLineFail "on", pmoabphcAlmLineHwFail "*", pmoabphctrapBoardNumber "$3"}
	--&MESG        "Critical Alarm appears on Pre-Amp input or Booster Output of PMOABPHC in slot $3 ($A)"
	
	--&FILTNAME    "PMOABPHC Line HW Fail ON (Hidden)"
	--&ACTIONS     { info }
	--&MATCH       { pmoabphcAlmLineFail "*", pmoabphcAlmLineHwFail "on", pmoabphctrapBoardNumber "$3"}
	--&MESG        "Critical Alarm appears on Pre-Amp input or Booster Output of PMOABPHC in slot $3 ($A)"
	DESCRIPTION "Critical Line default is activated"
	::= { pmoabphctraps 34 }

pmoabphcLineTrapCritGoesOff NOTIFICATION-TYPE
	OBJECTS {pmoabphcAlmLineFail, pmoabphcAlmLineHwFail, pmoabphctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOABPHC Line Fail OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      {"PMOABPHC Line Fail ON"}
	--&MATCH       { pmoabphcAlmLineFail "on", pmoabphcAlmLineHwFail "*", pmoabphctrapBoardNumber "$3"}
	--&MESG        "Critical Alarm disappears on Pre-Amp input or Booster Output of PMOABPHC in slot $3 ($A)"
	
	--&FILTNAME    "PMOABPHC Line HW Fail OFF (Hidden)"
	--&ACTIONS     { info }
	--&MATCH       { pmoabphcAlmLineFail "*", pmoabphcAlmLineHwFail "on", pmoabphctrapBoardNumber "$3"}
	--&MESG        "Critical Alarm disappears on Pre-Amp input or Booster Output of PMOABPHC in slot $3 ($A)"
	DESCRIPTION "Critical Line default disappeared"
	::= { pmoabphctraps 35 }






--- *****************************************************
---     PORTS TRAPS
--- *****************************************************

pmoabphcClientTrapNotUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pmoabphcAlmClientDdmWarning, pmoabphctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOABPHC Client Not Urgent ON"
	--&ACTIONS     { log, minor }
	--&MATCH       { pmoabphcAlmClientDdmWarning "on", pmoabphctrapBoardNumber "$2"}
	--&MESG        "DDM Warning appears on Booster input or Pre-Amp Output of PMOABPHC in slot $2 ($A)"
	DESCRIPTION "Not urgent client default is activated"
	::= { pmoabphctraps 40 }

pmoabphcClientTrapNotUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pmoabphcAlmClientDdmWarning, pmoabphctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOABPHC Client Not Urgent OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      {"PMOABPHC Client Not Urgent ON"}
	--&MATCH       { pmoabphcAlmClientDdmWarning "on", pmoabphctrapBoardNumber "$2"}
	--&MESG        "DDM Warning disappears on Booster input or Pre-Amp Output of PMOABPHC in slot $2 ($A)"
	DESCRIPTION "Not urgent client default disappeared"
	::= { pmoabphctraps 41 }

pmoabphcClientTrapUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pmoabphcAlmClientDdmAlm, pmoabphctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOABPHC Client Urgent ON"
	--&ACTIONS     { log, major }
	--&MATCH       { pmoabphcAlmClientDdmAlm "on", pmoabphctrapBoardNumber "$2"}
	--&MESG        "DDM Alarm appears on Booster input or Pre-Amp Output of PMOABPHC in slot $2 ($A)"
	DESCRIPTION "Urgent client default is activated"
	::= { pmoabphctraps 42 }

pmoabphcClientTrapUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pmoabphcAlmClientDdmAlm, pmoabphctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOABPHC Client Urgent OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      {"PMOABPHC Client Urgent ON"}
	--&MATCH       { pmoabphcAlmClientDdmAlm "on", pmoabphctrapBoardNumber "$2"}
	--&MESG        "DDM Alarm disappears on Booster input or Pre-Amp Output of PMOABPHC in slot $2 ($A)"
	DESCRIPTION "Urgent client default disappeared"
	::= { pmoabphctraps 43 }

pmoabphcClientTrapCritGoesOn NOTIFICATION-TYPE
	OBJECTS {pmoabphcAlmClientFail, pmoabphcAlmClientHwFail, pmoabphctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOABPHC Client Fail ON"
	--&ACTIONS     { log, critical }
	--&MATCH       { pmoabphcAlmClientFail "on", pmoabphcAlmClientHwFail "*", pmoabphctrapBoardNumber "$3"}
	--&MESG        "Critical Alarm appears on Booster input or Pre-Amp Output of PMOABPHC in slot $3 ($A)"
	
	--&FILTNAME    "PMOABPHC Client HW Fail ON (Hidden)"
	--&ACTIONS     { info }
	--&MATCH       { pmoabphcAlmClientFail "*", pmoabphcAlmClientHwFail "on", pmoabphctrapBoardNumber "$3"}
	--&MESG        "Critical Alarm appears on Booster input or Pre-Amp Output of PMOABPHC in slot $3 ($A)"
	DESCRIPTION "Critical client default is activated"
	::= { pmoabphctraps 44 }

pmoabphcClientTrapCritGoesOff NOTIFICATION-TYPE
	OBJECTS {pmoabphcAlmClientFail, pmoabphcAlmClientHwFail, pmoabphctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOABPHC Client Fail OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      {"PMOABPHC Client Fail ON"}
	--&MATCH       { pmoabphcAlmClientFail "on", pmoabphcAlmClientHwFail "*", pmoabphctrapBoardNumber "$3"}
	--&MESG        "Critical Alarm disappears on Booster input or Pre-Amp Output of PMOABPHC in slot $3 ($A)"
	
	--&FILTNAME    "PMOABPHC Client HW Fail OFF (Hidden)"
	--&ACTIONS     { info }
	--&MATCH       { pmoabphcAlmClientFail "*", pmoabphcAlmClientHwFail "on", pmoabphctrapBoardNumber "$3"}
	--&MESG        "Critical Alarm disappears on Booster input or Pre-Amp Output of PMOABPHC in slot $3 ($A)"
	DESCRIPTION "Critical client default disappeared"
	::= { pmoabphctraps 45 }






--- *****************************************************
---     HW TRAPS
--- *****************************************************

pmoabphcPowerTrapUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pmoabphcAlmDefFuseB, pmoabphcAlmDefFuseA , pmoabphctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOABPHC Fuse A Fail ON"
	--&ACTIONS     { log, major }
	--&MATCH       { pmoabphcAlmDefFuseB "*", pmoabphcAlmDefFuseA "on", pmoabphctrapBoardNumber "$3"}
	--&MESG        "Power Input A Fail on PMOABPHC in Slot $3 ($A)"

	--&FILTNAME    "PMOABPHC Fuse B Fail ON"
	--&ACTIONS     { log, major }
	--&MATCH       { pmoabphcAlmDefFuseB "on", pmoabphcAlmDefFuseA "*", pmoabphctrapBoardNumber "$3"}
	--&MESG        "Power Input B Fail on PMOABPHC in Slot $3 ($A)"
	DESCRIPTION "Urgent power supply default is activated"
	::= { pmoabphctraps 50 }
pmoabphcPowerTrapUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pmoabphcAlmDefFuseB, pmoabphcAlmDefFuseA , pmoabphctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOABPHC Fuse A&B Fail OFF"
	--&ACTIONS     { log, normal}
	--&CLEARS      { "PMOABPHC Fuse A Fail ON", "PMOABPHC Fuse B Fail ON" }
	--&MATCH       { pmoabphcAlmDefFuseB "on", pmoabphcAlmDefFuseA "on", pmoabphctrapBoardNumber "$3"}
	--&MESG        "Power Inputs A and B Present on PMOABPHC in Slot $3 ($A)"
	DESCRIPTION "Urgent power supply default disappeared"
	::= { pmoabphctraps 51 }






END