-- EKINOPS-pmoa.TXT:  MIB
--
--MIB Part Number:3MI00200AJAD
--MIB Version:01
--
-- Copyright (c) 2016 by Ekinops
-- All rights reserved.
-- 
-- *****************************************************************

EKINOPS-PmOa-MIB DEFINITIONS ::= BEGIN

IMPORTS
	ekinops,
	EkiState,
	EkiOnOff,
	EkiMode,
	EkiProtocol,
	EkiApiState,
	EkiSynchroMode,
	EkiMeasureType
			FROM EKINOPS-MIB
        MODULE-IDENTITY,
        OBJECT-TYPE,
        NOTIFICATION-TYPE,
	Unsigned32,
	Integer32,
	Counter32,
	IpAddress                
        		FROM SNMPv2-SMI
 	TEXTUAL-CONVENTION,
	DisplayString
                FROM SNMPv2-TC;

modulepmoa MODULE-IDENTITY
        LAST-UPDATED "201605230000Z"
        ORGANIZATION "Ekinops"
        CONTACT-INFO
         "Ekinops

          3, rue Blaise Pascal
          F-22300 Lannion / FRANCE

          Tel : +33 (0)2 96 05 00 30
          Fax : +33 (0)2 96 48 62 39

          E-mail: support@ekinops.net"
        DESCRIPTION
          "MIB for the Ekinops pmoa hardware."
	REVISION "200601050000Z"
	DESCRIPTION
	  "Initial Version."
	REVISION "200711210000Z"
	DESCRIPTION
	  "UPdate Ekinops address, Helps on objects, Ports labels"
	REVISION "200902050000Z"
	DESCRIPTION
	  "Add ext Pumps features"
	REVISION "200904080000Z"
	DESCRIPTION
	  "Cosmetic for mib compilers"
	REVISION "200909140000Z"
	DESCRIPTION
	  "CondType parameters insertion"
	REVISION "200912140000Z"
	DESCRIPTION
	  "Correction on traps"
	REVISION "201002240000Z"
	DESCRIPTION
	  "Probcause,AlarmType - NMS"
	REVISION "201007150000Z"
	DESCRIPTION
	  "Add inventory objet for the NMS"
	REVISION "201010290000Z"
	DESCRIPTION
	  "Formula in comments, Objects removal"

	REVISION "201011030000Z"
	DESCRIPTION
	  "Modify inventory objet for the NMS"
	REVISION "201207040000Z"
	DESCRIPTION
	  "Minor cosmetic updates"
	REVISION "201210050000Z"
	DESCRIPTION
	  "Minor labels changes"
	REVISION "201403260000Z"
	DESCRIPTION
	  "Probcause,AlarmType - NMS completion"
	REVISION "201411240000Z"
	DESCRIPTION
	  "Labels cosmetic updates"
	REVISION "201605230000Z"
	DESCRIPTION
	  "New AlarmType  synthesisAlarm (12)"
        ::= { ekinops 9 }



--- *****************************************************
---     LEAF LEVEL 2
--- *****************************************************


pmoaalarms OBJECT IDENTIFIER ::= { modulepmoa 2 }	
pmoaAlmOther OBJECT IDENTIFIER ::= { pmoaalarms 1 }
pmoaAlmOtherNurg OBJECT IDENTIFIER ::= { pmoaAlmOther 1 }
pmoaAlmOtherUrg OBJECT IDENTIFIER ::= { pmoaAlmOther 2 }
pmoaAlmOtherCrit OBJECT IDENTIFIER ::= { pmoaAlmOther 3 }

pmoaAlmClient OBJECT IDENTIFIER ::= { pmoaalarms 2 }
pmoaAlmClientNurg OBJECT IDENTIFIER ::= { pmoaAlmClient 1 }
pmoaAlmClientUrg OBJECT IDENTIFIER ::= { pmoaAlmClient 2 }
pmoaAlmClientCrit OBJECT IDENTIFIER ::= { pmoaAlmClient 3 }
	
pmoaAlmLine OBJECT IDENTIFIER ::= { pmoaalarms 3 }
pmoaAlmLineNurg OBJECT IDENTIFIER ::= { pmoaAlmLine 1 }
pmoaAlmLineUrg OBJECT IDENTIFIER ::= { pmoaAlmLine 2 }
pmoaAlmLineCrit OBJECT IDENTIFIER ::= { pmoaAlmLine 3 }


pmoameasures OBJECT IDENTIFIER ::= { modulepmoa 3 }	
pmoaMesrOther OBJECT IDENTIFIER ::= { pmoameasures 1 }	
pmoaMesrClient OBJECT IDENTIFIER ::= { pmoameasures 2 }	
pmoaMesrLine OBJECT IDENTIFIER ::= { pmoameasures 3 }	


pmoacontrolsWrite OBJECT IDENTIFIER ::= { modulepmoa 6 }
pmoaCtrlOther OBJECT IDENTIFIER ::= { pmoacontrolsWrite 1 }
pmoaCtrlClient OBJECT IDENTIFIER ::= { pmoacontrolsWrite 2 }
pmoaCtrlLine OBJECT IDENTIFIER ::= { pmoacontrolsWrite 3 }

pmoari OBJECT IDENTIFIER ::= { modulepmoa 7 }


pmoaConfig OBJECT IDENTIFIER ::= { modulepmoa 9 }

pmoatraps OBJECT IDENTIFIER ::= { modulepmoa 10 }


--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     TEXTUAL-CONVENTION
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************


PmoapreampMode ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION "Different modes on OA preamp"
    SYNTAX INTEGER {
		oapreampdefaultmode(0),
		oapreampconstantcurrentmode(1),
		oapreampconstantpowermode(2)

           }

PmoaboosterMode ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION "Different modes on OA booster"
    SYNTAX INTEGER {
		oaboosterdefaultmode(0),
		oaboosterconstantcurrentmode(1),
		oaboosterconstantpowermode(2)

           }


--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     REMOTE INVENTORY
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************

pmoaRinvReloadInventory OBJECT-TYPE
  SYNTAX EkiOnOff
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
        "Reload the inventory: This OID triggers an 
         inventory reload."
  ::= { pmoari 2 }
  
pmoaRinvModulePlatform OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
        "Module platform description: This OID contains the 
         description of the Module."
  ::= { pmoari 3 }
  
pmoaRinvSwPlatform OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
        "SW platform description: This OID contains the 
         description of the Software platform."
  ::= { pmoari 4 }

pmoaRinvSwFoa OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
        "Optical device driver description: This OID contains
	 the description of the driver of the optical devices 
	(Booster and Pre-Amp)"
  ::= { pmoari 5 }
  
  
pmoaRinvBoosterTable OBJECT-TYPE
      SYNTAX  SEQUENCE OF PmoaRinvBoosterEntry
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
              "List of the Boosters on the selected module"
      ::= { pmoari 6 }

pmoaRinvBoosterEntry OBJECT-TYPE
        SYNTAX  PmoaRinvBoosterEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
              "Row definition for the Boosters table"
        INDEX   { pmoaRinvBoosterIndex }
        ::= { pmoaRinvBoosterTable 1 }
    


PmoaRinvBoosterEntry::=
        SEQUENCE {
          pmoaRinvBoosterIndex 
              Integer32,
          pmoaRinvBooster
              DisplayString
        }


    pmoaRinvBoosterIndex OBJECT-TYPE
        SYNTAX  Integer32(1..16)
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
              "Index for Booster table"
        ::= { pmoaRinvBoosterEntry 1 }


    pmoaRinvBooster OBJECT-TYPE
        SYNTAX  DisplayString
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
              "Inventory for the Booster: This OID contains the inventory for the Booster"
        ::= { pmoaRinvBoosterEntry 2 }




pmoaRinvPreAmpTable OBJECT-TYPE
      SYNTAX  SEQUENCE OF PmoaRinvPreAmpEntry
      MAX-ACCESS  not-accessible
      STATUS  current
      DESCRIPTION
              "List of the PreAmps on the selected module"
      ::= { pmoari 7 }

pmoaRinvPreAmpEntry OBJECT-TYPE
        SYNTAX  PmoaRinvPreAmpEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
              "Row definition for the PreAmp table"
        INDEX   { pmoaRinvPreAmpIndex }
        ::= { pmoaRinvPreAmpTable 1 }
    


PmoaRinvPreAmpEntry::=
        SEQUENCE {
          pmoaRinvPreAmpIndex 
              Integer32,
          pmoaRinvPreAmp
              DisplayString
        }


    pmoaRinvPreAmpIndex OBJECT-TYPE
        SYNTAX  Integer32(1..16)
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
              "Index for PreAmp table"
        ::= { pmoaRinvPreAmpEntry 1 }


    pmoaRinvPreAmp OBJECT-TYPE
        SYNTAX  DisplayString
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
              "Inventory for the PreAmp: This OID contains the inventory for the PreAmp"
        ::= { pmoaRinvPreAmpEntry 2 }



  




--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     ALARMS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the synthAlm0 article
--- *****************************************************
pmoaAlmsynthAlm0 OBJECT IDENTIFIER ::= { pmoaAlmOtherCrit 0 }




pmoaAlmDefFuseB OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Fuse B Fail :This OID indicates 
        that the fuse of the power input 
        B is in fail condition  <Help>
          Status of the Fuse B <Condtype> 
        DEF_FUSE_B <Probcause> powerProblem 
        (36) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmsynthAlm0 16 }



pmoaAlmDefFuseA OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Fuse A Fail :This OID indicates 
        that the fuse of the power input 
        A is in fail condition  <Help>
          Status of the Fuse A <Condtype> 
        DEF_FUSE_A <Probcause> powerProblem 
        (36) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmsynthAlm0 15 }



pmoaAlmExtPumpNotLocked OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        External Pump1 Not Detected :This 
        OID indicates that the first external 
        pump is not detected by the amplifier 
        module  <Help>  This alarm indicates 
        if the first external pump is detected 
        by the amplifier module <Condtype> 
        EXT_PUMP_NOT_LOCKED <Probcause> 
        pumpFailure (39) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmsynthAlm0 12 }



pmoaAlmDwEdfaInitNotCompl OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Not Initialized :This
         OID indicates that the initialisation 
        of the Pre-Amp is not completed 
         <Help>  This status indicates
         if the Pre-Amp has been correctly 
        initialized <Condtype> DW_EDFA_INIT_NOT_COMPL 
        <Probcause> other (1) <Alarmtype> 
        other (1) <Polarity> (2) 
        "
	  ::= { pmoaAlmsynthAlm0 11 }



pmoaAlmUpEdfaInitNotCompl OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Not Initialized :This
         OID indicates that the initialisation 
        of the Booster is not completed 
         <Help>  This status indicates
         if the Booster has been correctly 
        initialized <Condtype> UP_EDFA_INIT_NOT_COMPL 
        <Probcause> other (1) <Alarmtype> 
        other (1) <Polarity> (2) 
        "
	  ::= { pmoaAlmsynthAlm0 10 }



pmoaAlmModGlobFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Module Failure :This OID is set 
        on detection of a failure originating 
        from the PM <Condtype> MOD_GLOB_FAIL 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	  ::= { pmoaAlmsynthAlm0 9 }



pmoaAlmMaintenanceMode OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Maintenance Mode :This OID indicates 
        that the PM is in maintenance mode 
         <Help>  This status indiates if 
        the module is currently in maintenance 
        mode <Condtype> MAINTENANCE_MODE 
        <Probcause> other (1) <Alarmtype> 
        other (1) <Polarity> (2) 
        "
	  ::= { pmoaAlmsynthAlm0 1 }



--- *****************************************************
---     LEAF for the synthAlm2 article
--- *****************************************************
pmoaAlmsynthAlm2 OBJECT IDENTIFIER ::= { pmoaAlmOtherNurg 2 }




pmoaAlmConfTableLoad OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        PM Configuration Load :This OID 
         is at 1 during the loading of
         configuration tables in the modules 
        RAM. <Condtype> CONF_TABLE_LOAD 
        <Probcause> other (1) <Alarmtype> 
        other (1) <Polarity> (2) 
        "
	  ::= { pmoaAlmsynthAlm2 3 }



pmoaAlmInvUpload OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Inventory Upload :This OID is
         at 1 during the uploading of PM 
        inventory information. <Condtype> 
        INV_UPLOAD <Probcause> other (1) 
        <Alarmtype> other (1) <Polarity> 
        (2) 
        "
	  ::= { pmoaAlmsynthAlm2 2 }



pmoaAlmConfTableSave OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        PM Configuration Save :This OID 
        is at 1 during the saving of a
         new configuration table in the 
        module Flash memory. <Condtype> 
        CONF_TABLE_SAVE <Probcause> other 
        (1) <Alarmtype> other (1) <Polarity> 
        (2) 
        "
	  ::= { pmoaAlmsynthAlm2 1 }



--- *****************************************************
---     LEAF for the synthAlm7 article
--- *****************************************************
pmoaAlmsynthAlm7 OBJECT IDENTIFIER ::= { pmoaAlmLineCrit 7 }




pmoaAlmLineFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line Port Failure :This OID indicates 
        a failure on the line port <Condtype> 
        LINE_FAIL <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	  ::= { pmoaAlmsynthAlm7 12 }



pmoaAlmLineDdmAlm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Alarm On Line Optical Module DDM 
        :This OID indicates an alarm is 
        present coming out of Line optical 
        interface DDM <Condtype> LINE_DDM_ALM 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	  ::= { pmoaAlmsynthAlm7 10 }



pmoaAlmLineDdmWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Warning On Line Optical Module 
        DDM :This OID indicates a warning 
        is present coming out of Line optical 
        interface DDM <Condtype> LINE_DDM_WARNING 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	  ::= { pmoaAlmsynthAlm7 9 }



pmoaAlmLineTxOff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Optical Output Shutdown 
        :This OID indicates the Booster 
        optical output power is on  <Help> 
         This status indicates if the Booster 
        laser pump is ON or OFF <Condtype> 
        LINE_TX_OFF <Probcause> other (1) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmoaAlmsynthAlm7 5 }



pmoaAlmLineHwFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line Port HW Failure :This OID 
        indicates a failure on line port, 
        most probably caused by a HW issue 
        <Condtype> LINE_HW_FAIL <Probcause> 
        equipmentMalfunction (16) <Alarmtype> 
        synthesisAlarm (12)  <Polarity> 
        (2) 
        "
	  ::= { pmoaAlmsynthAlm7 4 }



--- *****************************************************
---     LEAF for the synthAlm8 article
--- *****************************************************
pmoaAlmsynthAlm8 OBJECT IDENTIFIER ::= { pmoaAlmClientCrit 8 }




pmoaAlmClientFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Client Port Failure :This OID
         indicates a failure on the Client 
        port <Condtype> CLIENT_FAIL <Probcause> 
        equipmentMalfunction (16) <Alarmtype> 
        synthesisAlarm (12)  <Polarity> 
        (2) 
        "
	  ::= { pmoaAlmsynthAlm8 12 }



pmoaAlmClientDdmAlm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Alarm On Client Optical Module 
        DDM :This OID indicates an alarm 
        is present coming out of Client 
        optical interface DDM <Condtype> 
        CLIENT_DDM_ALM <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	  ::= { pmoaAlmsynthAlm8 10 }



pmoaAlmClientDdmWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Warning On Client Optical Module 
        DDM :This OID indicates a warning 
        is present coming out of Client 
        optical interface DDM <Condtype> 
        CLIENT_DDM_WARNING <Probcause>
         equipmentMalfunction (16) <Alarmtype> 
        synthesisAlarm (12)  <Polarity> 
        (2) 
        "
	  ::= { pmoaAlmsynthAlm8 9 }



pmoaAlmClientTxOff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Optical Output Shutdown 
        :This OID indicates the Pre-Amp 
        optical output power is on  <Help> 
         This status indicates if the Pre-Amp 
        laser pump transceiver laser is 
        ON or OFF <Condtype> CLIENT_TX_OFF 
        <Probcause> other (1) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmsynthAlm8 5 }



pmoaAlmClientHwFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Client Port HW Failure :This OID 
        indicates a failure on Client port, 
        most probably caused by a HW issue 
        <Condtype> CLIENT_HW_FAIL <Probcause> 
        equipmentMalfunction (16) <Alarmtype> 
        synthesisAlarm (12)  <Polarity> 
        (2) 
        "
	  ::= { pmoaAlmsynthAlm8 4 }



--- *****************************************************
---     LEAF for the clientEdfaAlarms1 article
--- *****************************************************
pmoaAlmclientEdfaAlarms1 OBJECT IDENTIFIER ::= { pmoaAlmClientUrg 32 }




pmoaAlmClientBiasHighAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Bias High Alarm :This
         OID indicates that the Bias is 
        higher than the alarm theshold
         of the Pre-Amp Optical Module
          <Help>  This alarm indicates
         if the Pre-Amp bias is too high 
        <Condtype> CLIENT_BIAS_HIGH_ALARM 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmclientEdfaAlarms1 8 }



pmoaAlmClientBiasLowAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Bias Low Alarm :This OID 
        indicates that the Bias is lower 
        than the alarm theshold of the
         Pre-Amp Optical Module  <Help> 
         This alarm indicates if the Pre-Amp 
        bias is too low <Condtype> CLIENT_BIAS_LOW_ALARM 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmclientEdfaAlarms1 7 }



pmoaAlmClientOutputPwrHighAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Tx Pwr High Alarm :This 
        OID indicates that the Transmit 
        Power is higher than the alarm
         theshold of the Pre-Amp Optical 
        Module  <Help>  This alarm indicates 
        if the Pre-Amp tx power is too
         high <Condtype> CLIENT_OUTPUT_PWR_HIGH_ALARM 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmclientEdfaAlarms1 6 }



pmoaAlmClientOutputPwrLowAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Tx Pwr Low Alarm :This 
        OID indicates that the Transmit 
        Power is lower than the alarm theshold 
        of the Pre-Amp Optical Module 
         <Help>  This alarm indicates if 
        the Pre-Amp tx power is too low 
        <Condtype> CLIENT_OUTPUT_PWR_LOW_ALARM 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmclientEdfaAlarms1 5 }



pmoaAlmClientInputPwrHighAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Rx Pwr High Alarm :This 
        OID indicates that the Receive
         Power is higher than the alarm 
        theshold of the Booster Optical 
        Module  <Help>  This alarm indicates 
        if the Booster rx power is too
         high <Condtype> CLIENT_INPUT_PWR_HIGH_ALARM 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmoaAlmclientEdfaAlarms1 4 }



pmoaAlmClientInputPwrLowAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Rx Pwr Low Alarm :This 
        OID indicates that the Receive
         Power is lower than the alarm
         theshold of the Booster Optical 
        Module  <Help>  This alarm indicates 
        if the Booster rx power is too
         low <Condtype> CLIENT_INPUT_PWR_LOW_ALARM 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmoaAlmclientEdfaAlarms1 3 }



pmoaAlmClientGainHighAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Gain High Alarm :This
         OID indicates that the Gain is 
        higher than the alarm threshold 
        of the Pre-Amp Module  <Help> 
         This alarm indicates if the Pre-Amp 
        gain is too high <Condtype> CLIENT_GAIN_HIGH_ALARM 
        <Probcause> performanceDegraded 
        (35) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmclientEdfaAlarms1 2 }



pmoaAlmClientGainLowAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Gain Low Alarm :This OID 
        indicates that the Gain is lower 
        than the alarm theshold of the
         Pre-Amp Module  <Help>  This alarm 
        indicates if the Pre-Amp gain is 
        too low <Condtype> CLIENT_GAIN_LOW_ALARM 
        <Probcause> performanceDegraded 
        (35) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmclientEdfaAlarms1 1 }



--- *****************************************************
---     LEAF for the clientEdfaWarnings article
--- *****************************************************
pmoaAlmclientEdfaWarnings OBJECT IDENTIFIER ::= { pmoaAlmClientNurg 33 }




pmoaAlmClientBiasHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Bias High Warning :This 
        OID indicates that the Bias is
         higher than the Warning theshold 
        of the Pre-Amp Optical Module 
         <Help>  This warning indicates 
        if the Pre-Amp bias is too high 
        <Condtype> CLIENT_BIAS_HIGH_WARNING 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmclientEdfaWarnings 8 }



pmoaAlmClientBiasLowWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Bias Low Warning :This 
        OID indicates that the Bias is
         lower than the Warning theshold 
        of the Pre-Amp Optical Module 
         <Help>  This warning indicates 
        if the Pre-Amp bias is too low
         <Condtype> CLIENT_BIAS_LOW_WARNING 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmclientEdfaWarnings 7 }



pmoaAlmClientOutputPwrHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Tx Pwr High Warning :This 
        OID indicates that the Transmit 
        Power is higher than the Warning 
        theshold of the Pre-Amp Optical 
        Module  <Help>  This warning indicates 
        if the Pre-Amp tx power is too
         high <Condtype> CLIENT_OUTPUT_PWR_HIGH_WARNING 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmclientEdfaWarnings 6 }



pmoaAlmClientOutputPwrLowWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Tx Pwr Low Warning :This 
        OID indicates that the Transmit 
        Power is lower than the Warning 
        theshold of the Pre-Amp Optical 
        Module  <Help>  This warning indicates 
        if the Pre-Amp tx power is too
         low <Condtype> CLIENT_OUTPUT_PWR_LOW_WARNING 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmclientEdfaWarnings 5 }



pmoaAlmClientInputPwrHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Rx Pwr High Warning :This 
        OID indicates that the Receive
         Power is higher than the Warning 
        theshold of the Booster Optical 
        Module  <Help>  This warning indicates 
        if the Booster rx power is too
         high <Condtype> CLIENT_INPUT_PWR_HIGH_WARNING 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmoaAlmclientEdfaWarnings 4 }



pmoaAlmClientInputPwrLowWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Rx Pwr Low Warning :This 
        OID indicates that the Receive
         Power is lower than the Warning 
        theshold of the Booster Optical 
        Module  <Help>  This warning indicates 
        if the Booster rx power is too
         low <Condtype> CLIENT_INPUT_PWR_LOW_WARNING 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmoaAlmclientEdfaWarnings 3 }



pmoaAlmClientGainHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Gain High Warning :This 
        OID indicates that the Gain is
         higher than the Warning threshold 
        of the Pre-Amp Module  <Help> 
         This alarm indicates if the Pre-Amp 
        gain is too high <Condtype> CLIENT_GAIN_HIGH_WARNING 
        <Probcause> performanceDegraded 
        (35) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmclientEdfaWarnings 2 }



pmoaAlmClientGainLowWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Gain Low Warning :This 
        OID indicates that the Gain is
         lower than the Warning theshold 
        of the Pre-Amp Module  <Help> 
         This alarm indicates if the Pre-Amp 
        gain is too low <Condtype> CLIENT_GAIN_LOW_WARNING 
        <Probcause> performanceDegraded 
        (35) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmclientEdfaWarnings 1 }



--- *****************************************************
---     LEAF for the clientEdfaAlarms2 article
--- *****************************************************
pmoaAlmclientEdfaAlarms2 OBJECT IDENTIFIER ::= { pmoaAlmClientCrit 35 }




pmoaAlmClientExtPumpEdfaLowCurrent OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp External Pump1 Low Current 
        :This OID indicates that the EDFA 
        pump current of the first external 
        pump linked to the Pre-Amp is too 
        low  <Help>  This alarm indicates 
        that the EDFA pump current of the 
        first external pump linked to the 
        Pre-Amp is too low <Condtype> CLIENT_EXT_PUMP_EDFA_LOW_CURRENT 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmclientEdfaAlarms2 5 }



pmoaAlmClientEdfaLos OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Loss Of Signal :This OID 
        indicates a Loss of Signal on the 
        Booster Optical Module  <Help>
          This alarm indicates if an optical 
        signal is detected on the Booster 
        input <Condtype> CLIENT_EDFA_LOS 
        <Probcause> receiveFailure (41) 
        <Alarmtype> physicalViolation (9) 
        <Polarity> (2) 
        "
	  ::= { pmoaAlmclientEdfaAlarms2 4 }



pmoaAlmClientEdfaLaserFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Pump Laser Fail :This
         OID indicates a Transmit Laser 
        Fail on the Pre-Amp Optical Module 
         <Help>  This alarm indicates if 
        the laser of the Pre-Amp is in
         fail condition <Condtype> CLIENT_EDFA_LASER_FAIL 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmclientEdfaAlarms2 3 }



pmoaAlmClientEdfaTecFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp TEC Fail :This OID indicates 
        that the TEC is in fail condition 
        on the Pre-Amp Optical Module 
         <Help>  This alarm indicates if 
        the TEC of the Pre-Amp is in fail 
        condition <Condtype> CLIENT_EDFA_TEC_FAIL 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmclientEdfaAlarms2 2 }



pmoaAlmClientEdfaNr OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Optical Module Not Ready 
        :This OID indicates that the Pre-Amp 
        Optical Module is not ready  <Help> 
         This status indicates if the Pre-Amp 
        has been correctly initialized
         <Condtype> CLIENT_EDFA_NR <Probcause> 
        equipmentMalfunction (16) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmclientEdfaAlarms2 1 }



--- *****************************************************
---     LEAF for the lineEdfaAlarms1 article
--- *****************************************************
pmoaAlmlineEdfaAlarms1 OBJECT IDENTIFIER ::= { pmoaAlmLineUrg 40 }




pmoaAlmLineBiasHighAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Bias High Alarm :This
         OID indicates that the Bias is 
        higher than the alarm theshold
         of the Booster Optical Module
          <Help>  This alarm indicates
         if the Booster bias is too high 
        <Condtype> LINE_BIAS_HIGH_ALARM 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmlineEdfaAlarms1 8 }



pmoaAlmLineBiasLowAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Bias Low Alarm :This OID 
        indicates that the Bias is lower 
        than the alarm theshold of the
         Booster Optical Module  <Help> 
         This alarm indicates if the Booster 
        bias is too low <Condtype> LINE_BIAS_LOW_ALARM 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmlineEdfaAlarms1 7 }



pmoaAlmLineOutputPwrHighAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Tx Pwr High Alarm :This 
        OID indicates that the Transmit 
        Power is higher than the alarm
         theshold of the Booster Optical 
        Module  <Help>  This alarm indicates 
        if the Booster tx power is too
         high <Condtype> LINE_OUTPUT_PWR_HIGH_ALARM 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmlineEdfaAlarms1 6 }



pmoaAlmLineOutputPwrLowAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Tx Pwr Low Alarm :This 
        OID indicates that the Transmit 
        Power is lower than the alarm theshold 
        of the Booster Optical Module 
         <Help>  This alarm indicates if 
        the Booster tx power is too low 
        <Condtype> LINE_OUTPUT_PWR_LOW_ALARM 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmlineEdfaAlarms1 5 }



pmoaAlmLineInputPwrHighAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Rx Pwr High Alarm :This 
        OID indicates that the Receive
         Power is higher than the alarm 
        theshold of the Pre-Amp Optical 
        Module  <Help>  This alarm indicates 
        if the Pre-Amp rx power is too
         high <Condtype> LINE_INPUT_PWR_HIGH_ALARM 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmoaAlmlineEdfaAlarms1 4 }



pmoaAlmLineInputPwrLowAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Rx Pwr Low Alarm :This 
        OID indicates that the Receive
         Power is lower than the alarm
         theshold of the Pre-Amp Optical 
        Module  <Help>  This alarm indicates 
        if the Pre-Amp rx power is too
         low <Condtype> LINE_INPUT_PWR_LOW_ALARM 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmoaAlmlineEdfaAlarms1 3 }



pmoaAlmLineGainHighAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Gain High Alarm :This
         OID indicates that the Gain is 
        higher than the alarm threshold 
        of the Booster Module  <Help> 
         This alarm indicates if the Booster 
        gain is too high <Condtype> LINE_GAIN_HIGH_ALARM 
        <Probcause> performanceDegraded 
        (35) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmlineEdfaAlarms1 2 }



pmoaAlmLineGainLowAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Gain Low Alarm :This OID 
        indicates that the Gain is lower 
        than the alarm theshold of the
         Booster Module  <Help>  This alarm 
        indicates if the Booster gain is 
        too low <Condtype> LINE_GAIN_LOW_ALARM 
        <Probcause> performanceDegraded 
        (35) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmlineEdfaAlarms1 1 }



--- *****************************************************
---     LEAF for the lineEdfaWarnings article
--- *****************************************************
pmoaAlmlineEdfaWarnings OBJECT IDENTIFIER ::= { pmoaAlmLineNurg 41 }




pmoaAlmLineBiasHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Bias High Warning :This 
        OID indicates that the Bias is
         higher than the Warning theshold 
        of the Booster Optical Module 
         <Help>  This warning indicates 
        if the Booster bias is too high 
        <Condtype> LINE_BIAS_HIGH_WARNING 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmlineEdfaWarnings 8 }



pmoaAlmLineBiasLowWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Bias Low Warning :This 
        OID indicates that the Bias is
         lower than the Warning theshold 
        of the Booster Optical Module 
         <Help>  This warning indicates 
        if the Booster bias is too low
         <Condtype> LINE_BIAS_LOW_WARNING 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmlineEdfaWarnings 7 }



pmoaAlmLineOutputPwrHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Tx Pwr High Warning :This 
        OID indicates that the Transmit 
        Power is higher than the Warning 
        theshold of the Booster Optical 
        Module  <Help>  This warning indicates 
        if the Booster tx power is too
         high <Condtype> LINE_OUTPUT_PWR_HIGH_WARNING 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmlineEdfaWarnings 6 }



pmoaAlmLineOutputPwrLowWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Tx Pwr Low Warning :This 
        OID indicates that the Transmit 
        Power is lower than the Warning 
        theshold of the Booster Optical 
        Module  <Help>  This warning indicates 
        if the Booster tx power is too
         low <Condtype> LINE_OUTPUT_PWR_LOW_WARNING 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmlineEdfaWarnings 5 }



pmoaAlmLineInputPwrHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Rx Pwr High Warning :This 
        OID indicates that the Receive
         Power is higher than the Warning 
        theshold of the Pre-Amp Optical 
        Module  <Help>  This warning indicates 
        if the Pre-Amp rx power is too
         high <Condtype> LINE_INPUT_PWR_HIGH_WARNING 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmoaAlmlineEdfaWarnings 4 }



pmoaAlmLineInputPwrLowWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Rx Pwr Low Warning :This 
        OID indicates that the Receive
         Power is lower than the Warning 
        theshold of the Pre-Amp Optical 
        Module  <Help>  This warning indicates 
        if the Pre-Amp rx power is too
         low <Condtype> LINE_INPUT_PWR_LOW_WARNING 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmoaAlmlineEdfaWarnings 3 }



pmoaAlmLineGainHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Gain High Warning :This 
        OID indicates that the Gain is
         higher than the Warning threshold 
        of the Booster Module  <Help> 
         This alarm indicates if the Booster 
        gain is too high <Condtype> LINE_GAIN_HIGH_WARNING 
        <Probcause> performanceDegraded 
        (35) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmlineEdfaWarnings 2 }



pmoaAlmLineGainLowWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Gain Low Warning :This 
        OID indicates that the Gain is
         lower than the Warning theshold 
        of the Booster Module  <Help> 
         This alarm indicates if the Booster 
        gain is too low <Condtype> LINE_GAIN_LOW_WARNING 
        <Probcause> performanceDegraded 
        (35) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmlineEdfaWarnings 1 }



--- *****************************************************
---     LEAF for the lineEdfaAlarms2 article
--- *****************************************************
pmoaAlmlineEdfaAlarms2 OBJECT IDENTIFIER ::= { pmoaAlmLineCrit 43 }




pmoaAlmLineExtPumpEdfaLowCurrent OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster External Pump1 Low Current 
        :This OID indicates that the EDFA 
        pump current of the first external 
        pump linked to the Booster is too 
        low  <Help>  This alarm indicates 
        that the EDFA pump current of the 
        first external pump linked to the 
        Booster is too low. <Condtype>
         LINE_EXT_PUMP_EDFA_LOW_CURRENT 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmlineEdfaAlarms2 5 }



pmoaAlmLineEdfaLos OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Loss Of Signal :This OID 
        indicates a Loss of Signal on the 
        Pre-Amp Optical Module  <Help>
          This alarm indicates if an optical 
        signal is detected on the Pre-Amp 
        input <Condtype> LINE_EDFA_LOS
         <Probcause> receiveFailure (41) 
        <Alarmtype> physicalViolation (9) 
        <Polarity> (2) 
        "
	  ::= { pmoaAlmlineEdfaAlarms2 4 }



pmoaAlmLineEdfaLaserFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Pump Laser Fail :This
         OID indicates a Transmit Laser 
        Fail on the Booster Optical Module 
         <Help>  This alarm indicates if 
        the laser of the Booster is in
         fail condition <Condtype> LINE_EDFA_LASER_FAIL 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmlineEdfaAlarms2 3 }



pmoaAlmLineEdfaTecFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster TEC Fail :This OID indicates 
        that the TEC is in fail condition 
        on the Booster Optical Module 
         <Help>  This alarm indicates if 
        the TEC of the Booster is in fail 
        condition <Condtype> LINE_EDFA_TEC_FAIL 
        <Probcause> pumpFailure (39) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmlineEdfaAlarms2 2 }



pmoaAlmLineEdfaNr OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Optical Module Not Ready 
        :This OID indicates that the Booster 
        Optical Module is not ready  <Help> 
         This status indicates if the Booster 
        has been correctly initialized
         <Condtype> LINE_EDFA_NR <Probcause> 
        equipmentMalfunction (16) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmlineEdfaAlarms2 1 }



--- *****************************************************
---     LEAF for the foaAlarms article
--- *****************************************************
pmoaAlmfoaAlarms OBJECT IDENTIFIER ::= { pmoaAlmOtherUrg 74 }




pmoaAlmTempHighAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Temperature High Alarm :This OID 
        indicates that the PM temperature 
        is higher than the alarm threshold 
        <Condtype> TEMP_HIGH_ALARM <Probcause> 
        temperatureUnacceptable (51) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmfoaAlarms 8 }



pmoaAlmTermpLowAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Temperature Low Alarm :This OID 
        indicates that the PM temperature 
        if lower than the alarm threshold 
        <Condtype> TERMP_LOW_ALARM <Probcause> 
        temperatureUnacceptable (51) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmfoaAlarms 7 }



pmoaAlm3v3HighAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        3V3 High Alarm :This OID indicates 
        that the PM 3V3 voltage is higher 
        than the alarm threshold <Condtype> 
        3V3_HIGH_ALARM <Probcause> powerProblem 
        (36) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmfoaAlarms 6 }



pmoaAlm3v3LowAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        3V3 Low Alarm :This OID indicates 
        that the PM 3V3 voltage is lower 
        than the alarm threshold <Condtype> 
        3V3_LOW_ALARM <Probcause> powerProblem 
        (36) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmfoaAlarms 5 }



--- *****************************************************
---     LEAF for the foaWarnings article
--- *****************************************************
pmoaAlmfoaWarnings OBJECT IDENTIFIER ::= { pmoaAlmOtherNurg 75 }




pmoaAlmTempHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Temperature High Warning :This 
        OID indicates that the PM temperature 
        if higher than the Warning threshold 
        <Condtype> TEMP_HIGH_WARNING <Probcause> 
        temperatureUnacceptable (51) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmfoaWarnings 8 }



pmoaAlmTermpLowWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Temperature Low Warning :This
         OID indicates that the PM temperature 
        if lower than the Warning threshold 
        <Condtype> TERMP_LOW_WARNING <Probcause> 
        temperatureUnacceptable (51) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmfoaWarnings 7 }



pmoaAlm3v3HighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        3V3 High Warning :This OID indicates 
        that the PM 3V3 voltage is higher 
        than the Warning threshold <Condtype> 
        3V3_HIGH_WARNING <Probcause> powerProblem 
        (36) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmfoaWarnings 6 }



pmoaAlm3v3LowWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        3V3 Low Warning :This OID indicates 
        that the PM 3V3 voltage is lower 
        than the Warning threshold <Condtype> 
        3V3_LOW_WARNING <Probcause> powerProblem 
        (36) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmoaAlmfoaWarnings 5 }








--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     CONTROLS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the synth0 article
--- *****************************************************
pmoaCtrlsynth0 OBJECT IDENTIFIER ::= { pmoaCtrlOther 0 }




pmoaCtrlConfClear OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Clear Configuration Tables :This 
        bit clears the configuration tables 
        from configuration in the flash. 
         <Help>  This control restores
         the default configuration of the 
        module
        "
	  ::= { pmoaCtrlsynth0 13 }



pmoaCtrlConfFlash OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Write Configuration Tables :This 
        bit saves the current configuration 
        of the module as configuration
         in the flash.  <Help>  This control 
        saves the customer configuration 
        on the module
        "
	  ::= { pmoaCtrlsynth0 9 }



pmoaCtrlConfLoad OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Load Configuration Tables :When 
        set this enables loading from flash 
        configuration1 into the module.
        "
	  ::= { pmoaCtrlsynth0 1 }



--- *****************************************************
---     LEAF for the swMgnt article
--- *****************************************************
pmoaCtrlswMgnt OBJECT IDENTIFIER ::= { pmoaCtrlOther 5 }




pmoaCtrlWarmReset OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        PM Warm Reset :This OID, when
         set, causes a warm reset of the 
        Software. This reset is not traffic 
        affecting, and the configuration 
        of the Sofwtare remains unchanged. 
         <Help>  This control initiates 
        a warm reset of the module.
        "
	  ::= { pmoaCtrlswMgnt 3 }



pmoaCtrlColdReset OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        PM Cold Reset :This OID, when
         set, causes a cold reset of the 
        Software. This reset is traffic 
        affecting, and the configuration 
        of Software is reloaded on start-up. 
         <Help>  This control initiates 
        a cold reset of the module.
        "
	  ::= { pmoaCtrlswMgnt 2 }



--- *****************************************************
---     LEAF for the clientEdfaLaserOff article
--- *****************************************************
pmoaCtrlclientEdfaLaserOff OBJECT IDENTIFIER ::= { pmoaCtrlClient 32 }




pmoaCtrlClientEdfaLaserOff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Pump Laser Shutdown :This 
        OID switches OFF the laser of the 
        Pre-Amp Optical Module  <Help>
          This control defines the laser 
        state of the Pre-Amp
        "
	  ::= { pmoaCtrlclientEdfaLaserOff 1 }



--- *****************************************************
---     LEAF for the clientEdfaMode article
--- *****************************************************

pmoaCtrlclientEdfaMode OBJECT-TYPE
	  SYNTAX PmoapreampMode
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Module Mode :This OID
         selects the mode of the Pre-Amp 
        Module  <Help>  This control defines 
        the Pre-Amp Mode (0: Default mode, 
        2:Constant output power)
        "
	  ::= { pmoaCtrlClient 33 }



--- *****************************************************
---     LEAF for the clientIlasSettingValue article
--- *****************************************************

pmoaCtrlclientIlasSettingValue OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Laser Current Value :This 
        OID sets the value of the laser 
        current of the Pre-Amp Module (active 
         only in constant current mode) 
        (AV = Current *100) (Unit = mA) 
         <Help>  This control defines the 
        Pre-Amp Laser current in mA (valid 
        only in constant current mode)
        "
	  ::= { pmoaCtrlClient 34 }



--- *****************************************************
---     LEAF for the clientPlasSettingValue article
--- *****************************************************

pmoaCtrlclientPlasSettingValue OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Pump Power Value :This 
        OID sets the value of the laser 
        power of the Pre-Amp Optical Module 
        (active only in constant power
         mode) (AV=(Power/0,005) + 32768) 
        (Unit = dBm)  <Help>  This control 
        defines the Pre-Amp laser power 
        in dBm (valid only in constant
         output power mode)
        "
	  ::= { pmoaCtrlClient 35 }



--- *****************************************************
---     LEAF for the clientGainSettingValue article
--- *****************************************************

pmoaCtrlclientGainSettingValue OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Gain Value :This OID sets 
        the value of the gain of the Pre-Amp 
        Module (active only in constant 
        gain mode) (AV=(Gain/0,005) + 32768) 
        (Unit = dB)
        "
	  ::= { pmoaCtrlClient 36 }



--- *****************************************************
---     LEAF for the clientEffPwrOutSettingValue article
--- *****************************************************

pmoaCtrlclientEffPwrOutSettingValue OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Effective Output Power 
        :This OID sets the value of the 
        effective output power (without 
        noise power) of the Pre-Amp Module 
        (active only in input power function 
        mode) (AV=(Power/0,005) + 32768) 
        (Unit = dBm)  <Help>  This control 
        defines the Pre-Amp effective output 
        power in dBm (valid only in Effective 
        Ouput power mode).
        "
	  ::= { pmoaCtrlClient 37 }



--- *****************************************************
---     LEAF for the lineEdfaLaserOff article
--- *****************************************************
pmoaCtrllineEdfaLaserOff OBJECT IDENTIFIER ::= { pmoaCtrlLine 40 }




pmoaCtrlLineEdfaLaserOff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Booster Pump Laser Shutdown :This 
        OID switches OFF the laser of the 
        Booster Optical Module  <Help>
          This control defines the laser 
        state of the Booster
        "
	  ::= { pmoaCtrllineEdfaLaserOff 1 }



--- *****************************************************
---     LEAF for the lineEdfaMode article
--- *****************************************************

pmoaCtrllineEdfaMode OBJECT-TYPE
	  SYNTAX PmoaboosterMode
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Booster Module Mode :This OID
         selects the mode of the Booster 
        Module  <Help>  This control defines 
        the Booster Mode (0: Default mode, 
        2:Constant output power)
        "
	  ::= { pmoaCtrlLine 41 }



--- *****************************************************
---     LEAF for the lineIlasSettingValue article
--- *****************************************************

pmoaCtrllineIlasSettingValue OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Booster Laser Current Value :This 
        OID sets the value of the laser 
        current of the Booster Module (active 
         only in constant current mode) 
        (AV = Current *100) (Unit = mA) 
         <Help>  This control defines the 
        Booster Laser current in mA (valid 
        only in constant current mode)
        "
	  ::= { pmoaCtrlLine 42 }



--- *****************************************************
---     LEAF for the linePlasSettingValue article
--- *****************************************************

pmoaCtrllinePlasSettingValue OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Booster Pump Power Value :This 
        OID sets the value of the laser 
        power of the Booster Optical Module 
        (active only in constant power
         mode) (AV=(Power/0,005) + 32768) 
        (Unit = dBm)  <Help>  This control 
        defines the Booster laser power 
        in dBm (valid only in constant
         output power mode)
        "
	  ::= { pmoaCtrlLine 43 }



--- *****************************************************
---     LEAF for the lineGainSettingValue article
--- *****************************************************

pmoaCtrllineGainSettingValue OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Booster Gain Value :This OID sets 
        the value of the gain of the Booster 
        Module (active only in constant 
        gain mode) (AV=(Gain/0,005) + 32768) 
        (Unit = dB)
        "
	  ::= { pmoaCtrlLine 44 }



--- *****************************************************
---     LEAF for the lineEffPwrOutSettingValue article
--- *****************************************************

pmoaCtrllineEffPwrOutSettingValue OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Booster Effective Output Power 
        :This OID sets the value of the 
        effective output power (without 
        noise power) of the Booster Module 
        (active only in input power function 
        mode) (AV=(Power/0,005) + 32768) 
        (Unit = dBm)
        "
	  ::= { pmoaCtrlLine 45 }



--- *****************************************************
---     LEAF for the powerDown article
--- *****************************************************
pmoaCtrlpowerDown OBJECT IDENTIFIER ::= { pmoaCtrlOther 72 }




pmoaCtrlSoftPowerDown OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Module Software Shutdown :This 
        OID shuts down the PM Software
          <Help>  This control initiates 
        a shut down of software.
        "
	  ::= { pmoaCtrlpowerDown 1 }



--- *****************************************************
---     LEAF for the ledTest article
--- *****************************************************
pmoaCtrlledTest OBJECT IDENTIFIER ::= { pmoaCtrlOther 73 }




pmoaCtrlLedOff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Leds Off :This OID switches off 
        all the Leds as a test feature. 
         <Help>  This control initiates 
        a test leds turning all the LEDs 
        to OFF
        "
	  ::= { pmoaCtrlledTest 3 }



pmoaCtrlRedLed OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Red Leds Test :This OID switches 
        on all the red Leds as a test feature. 
         <Help>  This control initiates 
        a test leds turning all the LEDs 
        to red
        "
	  ::= { pmoaCtrlledTest 2 }



pmoaCtrlGreenLed OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Green Leds Test :This OID switches 
        on all the green Leds as a test 
        feature.  <Help>  This control
         initiates a test leds turning
         all the LEDs to green
        "
	  ::= { pmoaCtrlledTest 1 }



--- *****************************************************
---     LEAF for the maintMode article
--- *****************************************************
pmoaCtrlmaintMode OBJECT IDENTIFIER ::= { pmoaCtrlOther 75 }




pmoaCtrlMaintenance OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Module Maintenance Mode :This
         OID sets the PM in maintenance 
        mode  <Help>  This control enables 
        the maintenance mode of the module
        "
	  ::= { pmoaCtrlmaintMode 1 }








--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     MEASURES
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the clientEdfaBiasMeas article
--- *****************************************************

pmoaMesrclientEdfaBiasMeas OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Pump Laser Current :This 
        OID gives the pump laser current 
        of the Pre-Amp Optical Module (Current 
        =AV/100) (Unit = mA)  <Help>  This 
        measure gives the bias of the Pre-Amp 
        pump laser
        "
	  ::= { pmoaMesrClient 32 }



--- *****************************************************
---     LEAF for the clientEdfaTxpwrMeas article
--- *****************************************************

pmoaMesrclientEdfaTxpwrMeas OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Tx Power :This OID gives 
        the transmit power value of the 
        Pre-Amp Optical Module (Power =(AV-32768)*0,005) 
         (Unit = dBm)  <Help>  This measure 
        gives the Tx optical power of the 
        Pre-Amp
        "
	  ::= { pmoaMesrClient 33 }



--- *****************************************************
---     LEAF for the clientEdfaRxpwrMeas article
--- *****************************************************

pmoaMesrclientEdfaRxpwrMeas OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Rx Power :This OID gives 
        the receive power value of the
         Booster Optical Module (Power
         =(AV-32768)*0,005) (Unit = dBm) 
         <Help>  This measure gives the 
        Rx optical power of the Booster
        "
	  ::= { pmoaMesrClient 34 }



--- *****************************************************
---     LEAF for the clientEdfaGainMeas article
--- *****************************************************

pmoaMesrclientEdfaGainMeas OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Gain :This OID gives the 
        gain value of the Pre-Amp Module 
         (Gain =(AV-32768)*0,005) (Unit 
        = dB)  <Help>  This measure gives 
        the optical gain of the Pre-Amp
        "
	  ::= { pmoaMesrClient 35 }



--- *****************************************************
---     LEAF for the lineEdfaBiasMeas article
--- *****************************************************

pmoaMesrlineEdfaBiasMeas OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Pump Laser Current :This 
        OID gives the pump laser current 
        of the Booster Optical Module 
         (Current =AV/100) (Unit = mA)
          <Help>  This measure gives the 
        bias of the Booster pump laser
        "
	  ::= { pmoaMesrLine 40 }



--- *****************************************************
---     LEAF for the lineEdfaTxpwrMeas article
--- *****************************************************

pmoaMesrlineEdfaTxpwrMeas OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Tx Power :This OID gives 
        the transmit power value of the 
        Booster Optical Module (Power =(AV-32768)*0,005) 
        (Unit = dBm)  <Help>  This measure 
        gives the Tx optical power of the 
        Booster
        "
	  ::= { pmoaMesrLine 41 }



--- *****************************************************
---     LEAF for the lineEdfaRxpwrMeas article
--- *****************************************************

pmoaMesrlineEdfaRxpwrMeas OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Pre-Amp Rx Power :This OID gives 
        the receive power value of the
         Pre-Amp Optical Module (Power
         =(AV-32768)*0,005) (Unit = dBm) 
         <Help>  This measure gives the 
        Rx optical power of the Pre-Amp
        "
	  ::= { pmoaMesrLine 42 }



--- *****************************************************
---     LEAF for the lineEdfaGainMeas article
--- *****************************************************

pmoaMesrlineEdfaGainMeas OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Booster Gain :This OID gives the 
        gain value of the Booster Module 
         (Gain =(AV-32768)*0,005) (Unit 
        = dB)  <Help>  This measure gives 
        the optical gain of the Booster
        "
	  ::= { pmoaMesrLine 43 }



--- *****************************************************
---     LEAF for the tempMeas article
--- *****************************************************

pmoaMesrtempMeas OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Module Temperature :This OID gives 
        the temperature of the PM  (Temperature 
        =AV/256) (Unit = C)  <Help>  This 
        measure gives the temperature of 
        the module
        "
	  ::= { pmoaMesrOther 72 }



--- *****************************************************
---     LEAF for the 3v3Meas article
--- *****************************************************

pmoaMesr3v3Meas OBJECT-TYPE
	  SYNTAX INTEGER (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Module 3.3 Voltage :This OID gives 
        the 3V3 voltage of the PM (Voltage 
        =AV/10000) (Unit = V)  <Help> 
         This measure gives the 3V3 voltage 
        of the module
        "
	  ::= { pmoaMesrOther 73 }








--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     CONFIG
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the table Group noValue
--- *****************************************************

pmoaCfgNoValue OBJECT IDENTIFIER ::= { pmoaConfig 1 }



--- *****************************************************
---     LEAF for the table 2111
--- *****************************************************

pmoatableclientStartup OBJECT IDENTIFIER ::= { pmoaCfgNoValue 1 }



pmoaCfgclientEdfaLaserCtrl OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Client Laser 
        :This OID configures the default 
        initialisation settings on the
         client laser.
        "
	  ::= { pmoatableclientStartup 2 }



pmoaCfgclientEdfaLaserMode OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Client mode 
        :This OID configures the default 
        mode on the client amplifier.
        "
	  ::= { pmoatableclientStartup 3 }



--- *****************************************************
---     LEAF for the table Group lineStartUp
--- *****************************************************

pmoaCfgLineStartUp OBJECT IDENTIFIER ::= { pmoaConfig 2 }



--- *****************************************************
---     LEAF for the table 2191
--- *****************************************************

pmoatablelineStartup OBJECT IDENTIFIER ::= { pmoaCfgLineStartUp 1 }



pmoaCfglineEdfaLaserCtrl OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Line Laser 
        :This OID configures the default 
        initialisation settings on the
         line laser.
        "
	  ::= { pmoatablelineStartup 2 }



pmoaCfglineEdfaLaserMode OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Line mode
         :This OID configures the default 
        mode on the line amplifier.
        "
	  ::= { pmoatablelineStartup 3 }



--- *****************************************************
---     LEAF for the table Group labels
--- *****************************************************

pmoaCfgLabels OBJECT IDENTIFIER ::= { pmoaConfig 3 }



--- *****************************************************
---     LEAF for the table NO_VALUE
--- *****************************************************

pmoaCfgLabelclientTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PmoaCfgLabelclientEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pmoaCfgLabels 1 }


pmoaCfgLabelclientEntry OBJECT-TYPE
	SYNTAX PmoaCfgLabelclientEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the labels
         table
        "
	INDEX   { pmoaCfgLabelclientIndex }
	::= { pmoaCfgLabelclientTable 1 }


PmoaCfgLabelclientEntry ::=
	SEQUENCE {
	pmoaCfgLabelclientIndex
		INTEGER,
	pmoaCfgLabelclientPortn
		DisplayString
	}


pmoaCfgLabelclientIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the labelclient 
        table
        "
	::= { pmoaCfgLabelclientEntry 1 }


pmoaCfgLabelclientPortn OBJECT-TYPE
	SYNTAX  DisplayString( SIZE(1..16))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default settings on the label
         of the Ports :These registers
         configures the default initialisation 
        settings of the labels of the ports.
        "
	::= { pmoaCfgLabelclientEntry 3 }


--- *****************************************************
---     LEAF for the table NO_VALUE
--- *****************************************************

pmoaCfgLabellineTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PmoaCfgLabellineEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pmoaCfgLabels 2 }


pmoaCfgLabellineEntry OBJECT-TYPE
	SYNTAX PmoaCfgLabellineEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the labels
         table
        "
	INDEX   { pmoaCfgLabellineIndex }
	::= { pmoaCfgLabellineTable 1 }


PmoaCfgLabellineEntry ::=
	SEQUENCE {
	pmoaCfgLabellineIndex
		INTEGER,
	pmoaCfgLabellinePortn
		DisplayString
	}


pmoaCfgLabellineIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the labelline 
        table
        "
	::= { pmoaCfgLabellineEntry 1 }


pmoaCfgLabellinePortn OBJECT-TYPE
	SYNTAX  DisplayString( SIZE(1..16))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default settings on the label
         of the lines :These registers
         configures the default initialisation 
        settings of the labels of the lines.
        "
	::= { pmoaCfgLabellineEntry 3 }



pmoaCfgWriteConfiguration  OBJECT-TYPE
	SYNTAX EkiOnOff
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
	"Write configuration to module:This OID 
	 writes the complete configuration to the module"
	::= { pmoaConfig 257 }






--- *****************************************************
---     TRAP OBJECTS
--- *****************************************************

pmoatrapBoardNumber OBJECT-TYPE
	SYNTAX INTEGER(1..64)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
	"Last module which generates a trap"
	::= { pmoatraps 4 }







--- *****************************************************
---     GLOBAL TRAPS
--- *****************************************************

pmoaLineTrapNotUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pmoaAlmLineDdmWarning, pmoatrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOA Line Not Urgent ON"
	--&ACTIONS     { log, minor }
	--&MATCH       { pmoaAlmLineDdmWarning "on", pmoatrapBoardNumber "$2"}
	--&MESG        "DDM Warning appears on Pre-Amp input or Booster Output of PMOA-BP in slot $2 ($A)"
	DESCRIPTION "Not urgent Line default is activated"
	::= { pmoatraps 30 }

pmoaLineTrapNotUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pmoaAlmLineDdmWarning, pmoatrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOA Line Not Urgent OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      {"PMOA Line Not Urgent ON"}
	--&MATCH       { pmoaAlmLineDdmWarning "on", pmoatrapBoardNumber "$2"}
	--&MESG        "DDM Warning disappears on Pre-Amp input or Booster Output of PMOA-BP in slot $2 ($A)"
	DESCRIPTION "Not urgent Line default disappeared"
	::= { pmoatraps 31 }

pmoaLineTrapUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pmoaAlmLineDdmAlm, pmoatrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOA Line Urgent ON"
	--&ACTIONS     { log, major }
	--&MATCH       { pmoaAlmLineDdmAlm "on", pmoatrapBoardNumber "$2"}
	--&MESG        "DDM Alarm appears on Pre-Amp input or Booster Output of PMOA-BP in slot $2 ($A)"
	DESCRIPTION "Urgent Line default is activated"
	::= { pmoatraps 32 }

pmoaLineTrapUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pmoaAlmLineDdmAlm, pmoatrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOA Line Urgent OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      {"PMOA Line Urgent ON"}
	--&MATCH       { pmoaAlmLineDdmAlm "on", pmoatrapBoardNumber "$2"}
	--&MESG        "DDM Alarm disappears on Pre-Amp input or Booster Output of PMOA-BP in slot $2 ($A)"
	DESCRIPTION "Urgent Line default disappeared"
	::= { pmoatraps 33 }

pmoaLineTrapCritGoesOn NOTIFICATION-TYPE
	OBJECTS {pmoaAlmLineFail, pmoaAlmLineHwFail, pmoatrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOA Line Fail ON"
	--&ACTIONS     { log, critical }
	--&MATCH       { pmoaAlmLineFail "on", pmoaAlmLineHwFail "*", pmoatrapBoardNumber "$3"}
	--&MESG        "Critical Alarm appears on Pre-Amp input or Booster Output of PMOA-BP in slot $3 ($A)"
	
	--&FILTNAME    "PMOA Line HW Fail ON (Hidden)"
	--&ACTIONS     { info }
	--&MATCH       { pmoaAlmLineFail "*", pmoaAlmLineHwFail "on", pmoatrapBoardNumber "$3"}
	--&MESG        "Critical Alarm appears on Pre-Amp input or Booster Output of PMOA-BP in slot $3 ($A)"
	DESCRIPTION "Critical Line default is activated"
	::= { pmoatraps 34 }

pmoaLineTrapCritGoesOff NOTIFICATION-TYPE
	OBJECTS {pmoaAlmLineFail, pmoaAlmLineHwFail, pmoatrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOA Line Fail OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      {"PMOA Line Fail ON"}
	--&MATCH       { pmoaAlmLineFail "on", pmoaAlmLineHwFail "*", pmoatrapBoardNumber "$3"}
	--&MESG        "Critical Alarm disappears on Pre-Amp input or Booster Output of PMOA-BP in slot $3 ($A)"
	
	--&FILTNAME    "PMOA Line HW Fail OFF (Hidden)"
	--&ACTIONS     { info }
	--&MATCH       { pmoaAlmLineFail "*", pmoaAlmLineHwFail "on", pmoatrapBoardNumber "$3"}
	--&MESG        "Critical Alarm disappears on Pre-Amp input or Booster Output of PMOA-BP in slot $3 ($A)"
	DESCRIPTION "Critical Line default disappeared"
	::= { pmoatraps 35 }






--- *****************************************************
---     PORTS TRAPS
--- *****************************************************

pmoaClientTrapNotUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pmoaAlmClientDdmWarning, pmoatrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOA Client Not Urgent ON"
	--&ACTIONS     { log, minor }
	--&MATCH       { pmoaAlmClientDdmWarning "on", pmoatrapBoardNumber "$2"}
	--&MESG        "DDM Warning appears on Booster input or Pre-Amp Output of PMOA-BP in slot $2 ($A)"
	DESCRIPTION "Not urgent client default is activated"
	::= { pmoatraps 40 }

pmoaClientTrapNotUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pmoaAlmClientDdmWarning, pmoatrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOA Client Not Urgent OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      {"PMOA Client Not Urgent ON"}
	--&MATCH       { pmoaAlmClientDdmWarning "on", pmoatrapBoardNumber "$2"}
	--&MESG        "DDM Warning disappears on Booster input or Pre-Amp Output of PMOA-BP in slot $2 ($A)"
	DESCRIPTION "Not urgent client default disappeared"
	::= { pmoatraps 41 }

pmoaClientTrapUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pmoaAlmClientDdmAlm, pmoatrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOA Client Urgent ON"
	--&ACTIONS     { log, major }
	--&MATCH       { pmoaAlmClientDdmAlm "on", pmoatrapBoardNumber "$2"}
	--&MESG        "DDM Alarm appears on Booster input or Pre-Amp Output of PMOA-BP in slot $2 ($A)"
	DESCRIPTION "Urgent client default is activated"
	::= { pmoatraps 42 }

pmoaClientTrapUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pmoaAlmClientDdmAlm, pmoatrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOA Client Urgent OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      {"PMOA Client Urgent ON"}
	--&MATCH       { pmoaAlmClientDdmAlm "on", pmoatrapBoardNumber "$2"}
	--&MESG        "DDM Alarm disappears on Booster input or Pre-Amp Output of PMOA-BP in slot $2 ($A)"
	DESCRIPTION "Urgent client default disappeared"
	::= { pmoatraps 43 }

pmoaClientTrapCritGoesOn NOTIFICATION-TYPE
	OBJECTS {pmoaAlmClientFail, pmoaAlmClientHwFail, pmoatrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOA Client Fail ON"
	--&ACTIONS     { log, critical }
	--&MATCH       { pmoaAlmClientFail "on", pmoaAlmClientHwFail "*", pmoatrapBoardNumber "$3"}
	--&MESG        "Critical Alarm appears on Booster input or Pre-Amp Output of PMOA-BP in slot $3 ($A)"
	
	--&FILTNAME    "PMOA Client HW Fail ON (Hidden)"
	--&ACTIONS     { info }
	--&MATCH       { pmoaAlmClientFail "*", pmoaAlmClientHwFail "on", pmoatrapBoardNumber "$3"}
	--&MESG        "Critical Alarm appears on Booster input or Pre-Amp Output of PMOA-BP in slot $3 ($A)"
	DESCRIPTION "Critical client default is activated"
	::= { pmoatraps 44 }

pmoaClientTrapCritGoesOff NOTIFICATION-TYPE
	OBJECTS {pmoaAlmClientFail, pmoaAlmClientHwFail, pmoatrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOA Client Fail OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      {"PMOA Client Fail ON"}
	--&MATCH       { pmoaAlmClientFail "on", pmoaAlmClientHwFail "*", pmoatrapBoardNumber "$3"}
	--&MESG        "Critical Alarm disappears on Booster input or Pre-Amp Output of PMOA-BP in slot $3 ($A)"
	
	--&FILTNAME    "PMOA Client HW Fail OFF (Hidden)"
	--&ACTIONS     { info }
	--&MATCH       { pmoaAlmClientFail "*", pmoaAlmClientHwFail "on", pmoatrapBoardNumber "$3"}
	--&MESG        "Critical Alarm disappears on Booster input or Pre-Amp Output of PMOA-BP in slot $3 ($A)"
	DESCRIPTION "Critical client default disappeared"
	::= { pmoatraps 45 }






--- *****************************************************
---     HW TRAPS
--- *****************************************************

pmoaPowerTrapUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pmoaAlmDefFuseB, pmoaAlmDefFuseA , pmoatrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOA Fuse A Fail ON"
	--&ACTIONS     { log, major }
	--&MATCH       { pmoaAlmDefFuseB "*", pmoaAlmDefFuseA "on", pmoatrapBoardNumber "$3"}
	--&MESG        "Power Input A Fail on PMOA-BP in Slot $3 ($A)"

	--&FILTNAME    "PMOA Fuse B Fail ON"
	--&ACTIONS     { log, major }
	--&MATCH       { pmoaAlmDefFuseB "on", pmoaAlmDefFuseA "*", pmoatrapBoardNumber "$3"}
	--&MESG        "Power Input B Fail on PMOA-BP in Slot $3 ($A)"
	DESCRIPTION "Urgent power supply default is activated"
	::= { pmoatraps 50 }
pmoaPowerTrapUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pmoaAlmDefFuseB, pmoaAlmDefFuseA , pmoatrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMOA Fuse A&B Fail OFF"
	--&ACTIONS     { log, normal}
	--&CLEARS      { "PMOA Fuse A Fail ON", "PMOA Fuse B Fail ON" }
	--&MATCH       { pmoaAlmDefFuseB "on", pmoaAlmDefFuseA "on", pmoatrapBoardNumber "$3"}
	--&MESG        "Power Inputs A and B Present on PMOA-BP in Slot $3 ($A)"
	DESCRIPTION "Urgent power supply default disappeared"
	::= { pmoatraps 51 }






END