-- EKINOPS-PmMC.TXT:  MIB
--
--MIB Part Number:3MI00120AJAD
--MIB Version:02
--
-- Copyright (c) 2016 by Ekinops
-- All rights reserved.
-- 
-- *****************************************************************

EKINOPS-PmMC-MIB DEFINITIONS ::= BEGIN

IMPORTS
	ekinops,
	EkiState,
	EkiOnOff,
	EkiMode,
	EkiProtocol,
	EkiApiState,
	EkiSynchroMode,
	EkiMeasureType
			FROM EKINOPS-MIB
        MODULE-IDENTITY,
        OBJECT-TYPE,
        NOTIFICATION-TYPE,
	Unsigned32,
	Integer32,
	Counter32,
	IpAddress                
        		FROM SNMPv2-SMI
 	TEXTUAL-CONVENTION,
	DisplayString
                FROM SNMPv2-TC;

modulePmMC MODULE-IDENTITY
        LAST-UPDATED "201605230000Z"
        ORGANIZATION "Ekinops"
        CONTACT-INFO
         "Ekinops

          3, rue Blaise Pascal
          F-22300 Lannion / FRANCE

          Tel : +33 (0)2 96 05 00 30
          Fax : +33 (0)2 96 48 62 39

          E-mail: support@ekinops.net"
        DESCRIPTION
          "MIB for the Ekinops Pmmc hardware."
	REVISION "200701100000Z"
	DESCRIPTION
	  "Initial Version."
	REVISION "200706290000Z"
	DESCRIPTION
	  "C changed to C"
	REVISION "200708230000Z"
	DESCRIPTION
	  "Add Alarms Objects"
	REVISION "200711210000Z"
	DESCRIPTION
	  "Add Config Object, Update Ekinops address, Helps on objects, Ports Labels"
	REVISION "200904100000Z"
	DESCRIPTION
	  "Cosmetics for mib compilers"
	REVISION "200909180000Z"
	DESCRIPTION
	  "CondType Parameters insertion"
	REVISION "201002250000Z"
	DESCRIPTION
	  "Probcause,AlarmType - NMS"
	REVISION "201011040000Z"
	DESCRIPTION
	  "Formulas and Event on XFP init"
	REVISION "201012170000Z"
	DESCRIPTION
	  "Fix on Smpc trap"
	REVISION "201207040000Z"
	DESCRIPTION
	  "Minor cosmetic updates"
	REVISION "201403260000Z"
	DESCRIPTION
	  "Probcause,AlarmType - NMS completion"
	REVISION "201412110000Z"
	DESCRIPTION
	  "Labels cosmetic updates"
	REVISION "201605230000Z"
	DESCRIPTION
	  "New AlarmType  synthesisAlarm (12)"
        ::= { ekinops 21 }



--- *****************************************************
---     LEAF LEVEL 2
--- *****************************************************


pmmcalarms OBJECT IDENTIFIER ::= { modulePmMC 2 }	
pmmcAlmOther OBJECT IDENTIFIER ::= { pmmcalarms 1 }
pmmcAlmOtherNurg OBJECT IDENTIFIER ::= { pmmcAlmOther 1 }
pmmcAlmOtherUrg OBJECT IDENTIFIER ::= { pmmcAlmOther 2 }
pmmcAlmOtherCrit OBJECT IDENTIFIER ::= { pmmcAlmOther 3 }

pmmcAlmClient OBJECT IDENTIFIER ::= { pmmcalarms 2 }
pmmcAlmClientNurg OBJECT IDENTIFIER ::= { pmmcAlmClient 1 }
pmmcAlmClientUrg OBJECT IDENTIFIER ::= { pmmcAlmClient 2 }
pmmcAlmClientCrit OBJECT IDENTIFIER ::= { pmmcAlmClient 3 }
	
pmmcAlmLine OBJECT IDENTIFIER ::= { pmmcalarms 3 }
pmmcAlmLineNurg OBJECT IDENTIFIER ::= { pmmcAlmLine 1 }
pmmcAlmLineUrg OBJECT IDENTIFIER ::= { pmmcAlmLine 2 }
pmmcAlmLineCrit OBJECT IDENTIFIER ::= { pmmcAlmLine 3 }


pmmcmeasures OBJECT IDENTIFIER ::= { modulePmMC 3 }	
pmmcMesrOther OBJECT IDENTIFIER ::= { pmmcmeasures 1 }	
pmmcMesrClient OBJECT IDENTIFIER ::= { pmmcmeasures 2 }	
pmmcMesrLine OBJECT IDENTIFIER ::= { pmmcmeasures 3 }	


pmmccontrolsWrite OBJECT IDENTIFIER ::= { modulePmMC 6 }
pmmcCtrlOther OBJECT IDENTIFIER ::= { pmmccontrolsWrite 1 }
pmmcCtrlClient OBJECT IDENTIFIER ::= { pmmccontrolsWrite 2 }
pmmcCtrlLine OBJECT IDENTIFIER ::= { pmmccontrolsWrite 3 }

pmmcri OBJECT IDENTIFIER ::= { modulePmMC 7 }


pmmcConfig OBJECT IDENTIFIER ::= { modulePmMC 9 }

pmmctraps OBJECT IDENTIFIER ::= { modulePmMC 10 }


--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     TEXTUAL-CONVENTION
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************

PmmcBitRate ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION "different rates for a client and line ports"
    SYNTAX INTEGER {
		rateSTM16OC48(0),
		rate1GBE(1),
		rateSTM4OC12(2),
		rateSTM1OC3(3),
		rate2GFC(4),
		rate1GFC(5),
		rateFastEthernet(7),
		rateSTM16FEC(8),
		rateSTM4FEC(9),
		rateSTM1FEC(10)
           }

--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     REMOTE INVENTORY
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************

pmmcRinvReloadInventory OBJECT-TYPE
  SYNTAX EkiOnOff
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
        "Reload the inventory: This OID triggers an 
         inventory reload."
  ::= { pmmcri 2 }

  
pmmcRinvHwPlatform OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
        "Module platform description: This OID contains the 
         description of the Module."
  ::= { pmmcri 4 }
  
pmmcRinvSwPlatform OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
        "SW platform description: This OID contains the 
         description of the Software platform."
  ::= { pmmcri 5 }
  
pmmcRinvLine1SFP OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
        "Inventory for the SFP: This OID contains the inventory for the Port A SFP"
  ::= { pmmcri 6 }


pmmcRinvLine2SFP OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
        "Inventory for the SFP: This OID contains the inventory for the Port B SFP"
  ::= { pmmcri 7 }






--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     ALARMS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the synthAlm0 article
--- *****************************************************
pmmcAlmsynthAlm0 OBJECT IDENTIFIER ::= { pmmcAlmOtherCrit 0 }




pmmcAlmDefFuseB OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Fuse B Fail :This OID indicates 
        that the fuse of the power input 
        B is in fail condition  <Help>
          Status of the Fuse B <Condtype> 
        DEF_FUSE_B <Probcause> powerProblem 
        (36) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmsynthAlm0 16 }



pmmcAlmDefFuseA OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Fuse A Fail :This OID indicates 
        that the fuse of the power input 
        A is in fail condition  <Help>
          Status of the Fuse A <Condtype> 
        DEF_FUSE_A <Probcause> powerProblem 
        (36) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmsynthAlm0 15 }



pmmcAlmSynUnlock OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Synthesizer Not Locked :This OID 
        indicates that the frequency synthesizer 
        is not locked.  <Help>  This status 
        indicates if the clock synthesizer 
        is locked. <Condtype> SYN_UNLOCK 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmsynthAlm0 14 }



pmmcAlmModuleGlobFailure OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Module Failure :This OID is set 
        on detection of a failure originating 
        from the PM <Condtype> MODULE_GLOB_FAILURE 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	  ::= { pmmcAlmsynthAlm0 9 }



--- *****************************************************
---     LEAF for the synthAlm7 article
--- *****************************************************
pmmcAlmsynthAlm7 OBJECT IDENTIFIER ::= { pmmcAlmLineCrit 7 }




pmmcAlmLine2Fail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Failure :This OID indicates 
        a failure on the Line 2 <Condtype> 
        LINE2_FAIL <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	  ::= { pmmcAlmsynthAlm7 12 }



pmmcAlmLine2TrscvDdmAlm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Alarm DDM On Optical Module 2
         :This OID indicates an alarm is 
        present coming out of optical interface 
        DDM on Line 2  <Help>  This alarm 
        indicates if a DDM Alarm has been 
        detected on the line 2 transceiver 
        <Condtype> LINE2_TRSCV_DDM_ALM
         <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	  ::= { pmmcAlmsynthAlm7 10 }



pmmcAlmLine2TrscvDdmWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Warning DDM On Optical Module
         2 :This OID indicates a warning 
        is present coming out of optical 
        interface DDM on Line 2  <Help> 
         This alarm indicates if a DDM
         Warning has been detected on the 
        line 2 transceiver <Condtype> LINE2_TRSCV_DDM_WARNING 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	  ::= { pmmcAlmsynthAlm7 9 }



pmmcAlmLine2TrscvLsd OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 SFP Laser Shutdown :This 
        OID indicates the optical output 
        power is off on Line 2  <Help>
          This status indicates if the
         line 2 transceiver laser is ON 
        or OFF <Condtype> LINE2_TRSCV_LSD 
        <Probcause> other (1) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmsynthAlm7 5 }



pmmcAlmLine2HwFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 HW Failure :This OID indicates 
        a hardware failure on the Line
         2 <Condtype> LINE2_HW_FAIL <Probcause> 
        equipmentMalfunction (16) <Alarmtype> 
        synthesisAlarm (12)  <Polarity> 
        (2) 
        "
	  ::= { pmmcAlmsynthAlm7 4 }



pmmcAlmLine2TrscvDdmAbsent OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        DDM Supported On Line 2 SFP :This 
        OID indicates that the transceiver 
        module 2 does not support Digital 
        Diagnostic Monitoring Functions 
         <Help>  This status indicates
         if the line 2 transceiver includes 
        the DDM feature <Condtype> LINE2_TRSCV_DDM_ABSENT 
        <Probcause> informationalStatus(1000) 
        <Alarmtype> other (1) <Polarity> 
        (2) 
        "
	  ::= { pmmcAlmsynthAlm7 2 }



pmmcAlmLine2TrscvAbsent OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 SFP Absent :This OID indicates 
        that the transceiver module 2 is 
        not present.  <Help>  This alarm 
        indicates if the line 2 transceiver 
        is present. <Condtype> LINE2_TRSCV_ABSENT 
        <Probcause> inputOutputDeviceError 
        (24) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) <Event> ObjectCDINV
        "
	  ::= { pmmcAlmsynthAlm7 1 }



--- *****************************************************
---     LEAF for the synthAlm8 article
--- *****************************************************
pmmcAlmsynthAlm8 OBJECT IDENTIFIER ::= { pmmcAlmClientCrit 8 }




pmmcAlmLine1Fail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Failure :This OID indicates 
        a failure on the Line 1 <Condtype> 
        LINE1_FAIL <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	  ::= { pmmcAlmsynthAlm8 12 }



pmmcAlmLine1TrscvDdmAlm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Alarm DDM On Optical Module 1
         :This OID indicates an alarm is 
        present coming out of optical interface 
        DDM on Line 1  <Help>  This alarm 
        indicates if a DDM Alarm has been 
        detected on the line 1 transceiver 
        <Condtype> LINE1_TRSCV_DDM_ALM
         <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	  ::= { pmmcAlmsynthAlm8 10 }



pmmcAlmLine1TrscvDdmWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Warning DDM On Optical Module
         1 :This OID indicates a warning 
        is present coming out of optical 
        interface DDM on Line 1  <Help> 
         This alarm indicates if a DDM
         Warning has been detected on the 
        line 1 transceiver <Condtype> LINE1_TRSCV_DDM_WARNING 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	  ::= { pmmcAlmsynthAlm8 9 }



pmmcAlmLine1TrscvLsd OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 SFP Laser Shutdown :This 
        OID indicates the optical output 
        power is off on Line 1  <Help>
          This status indicates if the
         line 1 transceiver laser is ON 
        or OFF <Condtype> LINE1_TRSCV_LSD 
        <Probcause> other (1) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmsynthAlm8 5 }



pmmcAlmLine1HwFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 HW Failure :This OID indicates 
        a hardware failure on the Line
         1 <Condtype> LINE1_HW_FAIL <Probcause> 
        equipmentMalfunction (16) <Alarmtype> 
        synthesisAlarm (12)  <Polarity> 
        (2) 
        "
	  ::= { pmmcAlmsynthAlm8 4 }



pmmcAlmLine1TrscvDdmAbsent OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        DDM Supported On Line 1 SFP :This 
        OID indicates that the transceiver 
        module 1 does not support Digital 
        Diagnostic Monitoring Functions 
         <Help>  This status indicates
         if the line 1 transceiver includes 
        the DDM feature <Condtype> LINE1_TRSCV_DDM_ABSENT 
        <Probcause> informationalStatus(1000) 
        <Alarmtype> other (1) <Polarity> 
        (2) 
        "
	  ::= { pmmcAlmsynthAlm8 2 }



pmmcAlmLine1TrscvAbsent OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 SFP Absent :This OID indicates 
        that the transceiver module 2 is 
        not present.  <Help>  This alarm 
        indicates if the line 1 transceiver 
        is present. <Condtype> LINE1_TRSCV_ABSENT 
        <Probcause> inputOutputDeviceError 
        (24) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) <Event> ObjectCDINV
        "
	  ::= { pmmcAlmsynthAlm8 1 }



--- *****************************************************
---     LEAF for the line1AccessioAlm article
--- *****************************************************
pmmcAlmline1AccessioAlm OBJECT IDENTIFIER ::= { pmmcAlmClientCrit 16 }




pmmcAlmLine1Los OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Loss Of Optical Signal On Line 
        1 :This OID indicates that no signal 
        is present on the transceiver 1 
         <Help>  This alarm indicates if 
        an optical signal is detected on 
        the line 1 transceiver input <Condtype> 
        LINE1_LOS <Probcause> receiveFailure 
        (41) <Alarmtype> physicalViolation 
        (9) <Polarity> (2) 
        "
	  ::= { pmmcAlmline1AccessioAlm 4 }



pmmcAlmLine1LasFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 SFP Tx Failed :This OID 
        indicates that the transmitter
         fails for the transceiver plugged 
        into the Line 1 (this alarm reports 
        the transmitter failure alarm generated 
        by the transceivers)  <Help>  This 
        alarm indicates if the laser of 
        the Line 1 transceiver is in fail 
        condition <Condtype> LINE1_LAS_FAIL 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline1AccessioAlm 1 }



--- *****************************************************
---     LEAF for the line1TrscvAlmDdm article
--- *****************************************************
pmmcAlmline1TrscvAlmDdm OBJECT IDENTIFIER ::= { pmmcAlmClientUrg 18 }




pmmcAlmLine1RxPwrHighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 1 Rx Power High :Alarm indicating 
        that the transceiver input power 
        of Line 1 is higher than the threshold 
        value written in the transceiver 
        EEPROM <Condtype> LINE1_RX_PWR_HIGH_ALA 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmmcAlmline1TrscvAlmDdm 16 }



pmmcAlmLine1RxPwrLowAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 1 Rx Power Low :Alarm indicating 
        that the transceiver input power 
        of Line 1 is lower than the threshold 
        value written in the transceiver 
        EEPROM <Condtype> LINE1_RX_PWR_LOW_ALA 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmmcAlmline1TrscvAlmDdm 15 }



pmmcAlmLine1TempHighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 1 Temp High :Alarm indicating 
        that the transceiver temperature 
        of Line 1 is higher than the threshold 
        value written in the transceiver 
        EEPROM <Condtype> LINE1_TEMP_HIGH_ALA 
        <Probcause> temperatureUnacceptable 
        (51) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline1TrscvAlmDdm 8 }



pmmcAlmLine1TempLowAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 1 Temp Low :Alarm indicating 
        that the transceiver temperature 
        of Line 1 is lower than the threshold 
        value written in the transceiver 
        EEPROM <Condtype> LINE1_TEMP_LOW_ALA 
        <Probcause> temperatureUnacceptable 
        (51) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline1TrscvAlmDdm 7 }



pmmcAlmLine1VccHighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 1 Power Supply High :Alarm 
        indicating that the transceiver 
        power supply of Line 1 is higher 
        than the threshold value written 
        in the transceiver EEPROM  <Condtype> 
        LINE1_VCC_HIGH_ALA <Probcause>
         powerProblem (36) <Alarmtype>
         equipmentAlarm (5) <Polarity>
         (2) 
        "
	  ::= { pmmcAlmline1TrscvAlmDdm 6 }



pmmcAlmLine1VccLowAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 1 Power Supply Low :Alarm 
        indicating that the transceiver 
        power supply of Line 1 is lower 
        than the threshold value written 
        in the transceiver EEPROM  <Condtype> 
        LINE1_VCC_LOW_ALA <Probcause> powerProblem 
        (36) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline1TrscvAlmDdm 5 }



pmmcAlmLine1TxBiasHighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 1 Bias High :Alarm indicating 
        that the transceiver laser bias 
        current of Line 1 is higher than 
        the threshold value written in
         the transceiver EEPROM <Condtype> 
        LINE1_TX_BIAS_HIGH_ALA <Probcause> 
        transmitterFailure (56) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline1TrscvAlmDdm 4 }



pmmcAlmLine1TxBiasLowAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 1 Bias Low :Alarm indicating 
        that the transceiver laser bias 
        current of Line 1 is lower than 
        the threshold value written in
         the transceiver EEPROM <Condtype> 
        LINE1_TX_BIAS_LOW_ALA <Probcause> 
        transmitterFailure (56) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline1TrscvAlmDdm 3 }



pmmcAlmLine1TxPwrHighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 1 Tx Power High :Alarm indicating 
        that the transceiver output power 
        of Line 1 is higher than the threshold 
        value written in the transceiver 
        EEPROM <Condtype> LINE1_TX_PWR_HIGH_ALA 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline1TrscvAlmDdm 2 }



pmmcAlmLine1TxPwrLowAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 1 Tx Power Low :Alarm indicating 
        that the transceiver output power 
        of Line 1 is lower than the threshold 
        value written in the transceiver 
        EEPROM <Condtype> LINE1_TX_PWR_LOW_ALA 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline1TrscvAlmDdm 1 }



--- *****************************************************
---     LEAF for the line1TrscvWarnDdm article
--- *****************************************************
pmmcAlmline1TrscvWarnDdm OBJECT IDENTIFIER ::= { pmmcAlmClientNurg 20 }




pmmcAlmLine1RxPwrHighWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 1 Rx Power High Warning
         :Warning indicating that the transceiver 
        input power of Line 1 is higher 
        than the threshold value written 
        in the transceiver EEPROM <Condtype> 
        LINE1_RX_PWR_HIGH_WNG <Probcause> 
        receiveFailure (41) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline1TrscvWarnDdm 16 }



pmmcAlmLine1RxPwrLowWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 1 Rx Power Low Warning :Warning 
        indicating that the transceiver 
        input power of Line 1 is lower
         than the threshold value written 
        in the transceiver EEPROM <Condtype> 
        LINE1_RX_PWR_LOW_WNG <Probcause> 
        receiveFailure (41) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline1TrscvWarnDdm 15 }



pmmcAlmLine1TempHighWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 1 Temp High Warning :Warning 
        indicating that the transceiver 
        temperature of Line 1 is higher 
        than the threshold value written 
        in the transceiver EEPROM <Condtype> 
        LINE1_TEMP_HIGH_WNG <Probcause> 
        temperatureUnacceptable (51) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline1TrscvWarnDdm 8 }



pmmcAlmLine1TempLowWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 1 Temp Low Warning :Warning 
        indicating that the transceiver 
        temperature of Line 1 is lower
         than the threshold value written 
        in the transceiver EEPROM <Condtype> 
        LINE1_TEMP_LOW_WNG <Probcause>
         temperatureUnacceptable (51) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline1TrscvWarnDdm 7 }



pmmcAlmLine1VccHighWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 1 Power Supply High Warning 
        :Warning indicating that the transceiver 
        power supply of Line 1 is higher 
        than the threshold value written 
        in the transceiver EEPROM  <Condtype> 
        LINE1_VCC_HIGH_WNG <Probcause>
         powerProblem (36) <Alarmtype>
         equipmentAlarm (5) <Polarity>
         (2) 
        "
	  ::= { pmmcAlmline1TrscvWarnDdm 6 }



pmmcAlmLine1VccLowWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 1 Power Supply Low Warning 
        :Warning indicating that the transceiver 
        power supply of Line 1 is lower 
        than the threshold value written 
        in the transceiver EEPROM  <Condtype> 
        LINE1_VCC_LOW_WNG <Probcause> powerProblem 
        (36) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline1TrscvWarnDdm 5 }



pmmcAlmLine1TxBiasHighWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 1 Bias High Warning :Warning 
        indicating that the transceiver 
        laser bias current of Line 1 is 
        higher than the threshold value 
        written in the transceiver EEPROM 
        <Condtype> LINE1_TX_BIAS_HIGH_WNG 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline1TrscvWarnDdm 4 }



pmmcAlmLine1TxBiasLowWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 1 Bias Low Warning :Warning 
        indicating that the transceiver 
        laser bias current of Line 1 is 
        lower than the threshold value
         written in the transceiver EEPROM 
        <Condtype> LINE1_TX_BIAS_LOW_WNG 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline1TrscvWarnDdm 3 }



pmmcAlmLine1TxPwrHighWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 1 Tx Power High Warning
         :Warning indicating that the transceiver 
        output power of Line 1 is higher 
        than the threshold value written 
        in the transceiver EEPROM <Condtype> 
        LINE1_TX_PWR_HIGH_WNG <Probcause> 
        transmitterFailure (56) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline1TrscvWarnDdm 2 }



pmmcAlmLine1TxPwLowWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 1 Tx Power Low Warning :Warning 
        indicating that the transceiver 
        output power of Line 1 is lower 
        than the threshold value written 
        in the transceiver EEPROM <Condtype> 
        LINE1_TX_PW_LOW_WNG <Probcause> 
        transmitterFailure (56) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline1TrscvWarnDdm 1 }



--- *****************************************************
---     LEAF for the line1CdrAlm article
--- *****************************************************
pmmcAlmline1CdrAlm OBJECT IDENTIFIER ::= { pmmcAlmClientNurg 23 }




pmmcAlmLine1CdrRefAbsent OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 CDR Reference Clock Absent 
        :This OID indicates that the CDR 
        reference clock is absent on Line 
        1  <Help>  This alarm indicates 
        if the reference clock is present 
        on the line 1 CDR <Condtype> LINE1_CDR_REF_ABSENT 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline1CdrAlm 3 }



pmmcAlmLine1CdrLossoflock OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 CDR Loss Of Lock :This
         OID indicates that the Line 1
         CDR is not locked  <Help>  This 
        alarm indicates if Line 1 CDR is 
        correclty locked on the input signal 
        <Condtype> LINE1_CDR_LOSSOFLOCK 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmmcAlmline1CdrAlm 2 }



pmmcAlmLine1CdrLossofsignal OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 CDR Loss Of Signal :This 
        OID indicates that a Loss of electrical 
        signal is detected on the Line
         1 CDR  <Help>  This alarm indicates 
        if an electrical signal is detected 
        on the line 1 CDR <Condtype> LINE1_CDR_LOSSOFSIGNAL 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmmcAlmline1CdrAlm 1 }



--- *****************************************************
---     LEAF for the line2AccessioAlm article
--- *****************************************************
pmmcAlmline2AccessioAlm OBJECT IDENTIFIER ::= { pmmcAlmLineCrit 24 }




pmmcAlmLine2Los OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Loss Of Optical Signal On Line 
        2 :This OID indicates that no signal 
        is present on the transceiver 2 
         <Help>  This alarm indicates if 
        an optical signal is detected on 
        the line 2 transceiver input <Condtype> 
        LINE2_LOS <Probcause> receiveFailure 
        (41) <Alarmtype> physicalViolation 
        (9) <Polarity> (2) 
        "
	  ::= { pmmcAlmline2AccessioAlm 4 }



pmmcAlmLine2LasFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 SFP Tx Failed :This OID 
        indicates that the transmitter
         fails for the transceiver plugged 
        into the Line 1 (this alarm reports 
        the transmitter failure alarm generated 
        by the transceivers)  <Help>  This 
        alarm indicates if the laser of 
        the line 2 transceiver is in fail 
        condition <Condtype> LINE2_LAS_FAIL 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline2AccessioAlm 1 }



--- *****************************************************
---     LEAF for the line2TrscvAlmDdm article
--- *****************************************************
pmmcAlmline2TrscvAlmDdm OBJECT IDENTIFIER ::= { pmmcAlmLineUrg 26 }




pmmcAlmLine2RxPwrHighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 2 Rx Power High :Alarm indicating 
        that the transceiver input power 
        of Line 2 is higher than the threshold 
        value written in the transceiver 
        EEPROM <Condtype> LINE2_RX_PWR_HIGH_ALA 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmmcAlmline2TrscvAlmDdm 16 }



pmmcAlmLine2RxPwrLowAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 2 Rx Power Low :Alarm indicating 
        that the transceiver input power 
        of Line 2 is lower than the threshold 
        value written in the transceiver 
        EEPROM <Condtype> LINE2_RX_PWR_LOW_ALA 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmmcAlmline2TrscvAlmDdm 15 }



pmmcAlmLine2TempHighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 2 Temp High :Alarm indicating 
        that the transceiver temperature 
        of Line 2 is higher than the threshold 
        value written in the transceiver 
        EEPROM <Condtype> LINE2_TEMP_HIGH_ALA 
        <Probcause> temperatureUnacceptable 
        (51) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline2TrscvAlmDdm 8 }



pmmcAlmLine2TempLowAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 2 Temp Low :Alarm indicating 
        that the transceiver temperature 
        of Line 2 is lower than the threshold 
        value written in the transceiver 
        EEPROM <Condtype> LINE2_TEMP_LOW_ALA 
        <Probcause> temperatureUnacceptable 
        (51) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline2TrscvAlmDdm 7 }



pmmcAlmLine2VccHighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 2 Power Supply High :Alarm 
        indicating that the transceiver 
        power supply of Line 2 is higher 
        than the threshold value written 
        in the transceiver EEPROM  <Condtype> 
        LINE2_VCC_HIGH_ALA <Probcause>
         powerProblem (36) <Alarmtype>
         equipmentAlarm (5) <Polarity>
         (2) 
        "
	  ::= { pmmcAlmline2TrscvAlmDdm 6 }



pmmcAlmLine2VccLowAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 2 Power Supply Low :Alarm 
        indicating that the transceiver 
        power supply of Line 2 is lower 
        than the threshold value written 
        in the transceiver EEPROM  <Condtype> 
        LINE2_VCC_LOW_ALA <Probcause> powerProblem 
        (36) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline2TrscvAlmDdm 5 }



pmmcAlmLine2TxBiasHighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 2 Bias High :Alarm indicating 
        that the transceiver laser bias 
        current of Line 2 is higher than 
        the threshold value written in
         the transceiver EEPROM <Condtype> 
        LINE2_TX_BIAS_HIGH_ALA <Probcause> 
        transmitterFailure (56) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline2TrscvAlmDdm 4 }



pmmcAlmLine2TxBiasLowAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 2 Bias Low :Alarm indicating 
        that the transceiver laser bias 
        current of Line 2 is lower than 
        the threshold value written in
         the transceiver EEPROM <Condtype> 
        LINE2_TX_BIAS_LOW_ALA <Probcause> 
        transmitterFailure (56) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline2TrscvAlmDdm 3 }



pmmcAlmLine2TxPwrHighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 2 Tx Power High :Alarm indicating 
        that the transceiver output power 
        of Line 2 is higher than the threshold 
        value written in the transceiver 
        EEPROM <Condtype> LINE2_TX_PWR_HIGH_ALA 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline2TrscvAlmDdm 2 }



pmmcAlmLine2TxPwrLowAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 2 Tx Power Low :Alarm indicating 
        that the transceiver output power 
        of Line 2 is lower than the threshold 
        value written in the transceiver 
        EEPROM <Condtype> LINE2_TX_PWR_LOW_ALA 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline2TrscvAlmDdm 1 }



--- *****************************************************
---     LEAF for the line2TrscvWarnDdm article
--- *****************************************************
pmmcAlmline2TrscvWarnDdm OBJECT IDENTIFIER ::= { pmmcAlmLineNurg 28 }




pmmcAlmLine2RxPwrHighWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 2 Rx Power High Warning
         :Warning indicating that the transceiver 
        input power of Line 2 is higher 
        than the threshold value written 
        in the transceiver EEPROM <Condtype> 
        LINE2_RX_PWR_HIGH_WNG <Probcause> 
        receiveFailure (41) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline2TrscvWarnDdm 16 }



pmmcAlmLine2RxPwrLowWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 2 Rx Power Low Warning :Warning 
        indicating that the transceiver 
        input power of Line 2 is lower
         than the threshold value written 
        in the transceiver EEPROM <Condtype> 
        LINE2_RX_PWR_LOW_WNG <Probcause> 
        receiveFailure (41) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline2TrscvWarnDdm 15 }



pmmcAlmLine2TempHighWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 2 Temp High Warning :Warning 
        indicating that the transceiver 
        temperature of Line 2 is higher 
        than the threshold value written 
        in the transceiver EEPROM <Condtype> 
        LINE2_TEMP_HIGH_WNG <Probcause> 
        temperatureUnacceptable (51) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline2TrscvWarnDdm 8 }



pmmcAlmLine2TempLowWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 2 Temp Low Warning :Warning 
        indicating that the transceiver 
        temperature of Line 2 is lower
         than the threshold value written 
        in the transceiver EEPROM <Condtype> 
        LINE2_TEMP_LOW_WNG <Probcause>
         temperatureUnacceptable (51) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline2TrscvWarnDdm 7 }



pmmcAlmLine2VccHighWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 2 Power Supply High Warning 
        :Warning indicating that the transceiver 
        power supply of Line 2 is higher 
        than the threshold value written 
        in the transceiver EEPROM  <Condtype> 
        LINE2_VCC_HIGH_WNG <Probcause>
         powerProblem (36) <Alarmtype>
         equipmentAlarm (5) <Polarity>
         (2) 
        "
	  ::= { pmmcAlmline2TrscvWarnDdm 6 }



pmmcAlmLine2VccLowWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 2 Power Supply Low Warning 
        :Warning indicating that the transceiver 
        power supply of Line 2 is lower 
        than the threshold value written 
        in the transceiver EEPROM  <Condtype> 
        LINE2_VCC_LOW_WNG <Probcause> powerProblem 
        (36) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline2TrscvWarnDdm 5 }



pmmcAlmLine2TxBiasHighWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 2 Bias High Warning :Warning 
        indicating that the transceiver 
        laser bias current of Line 2 is 
        higher than the threshold value 
        written in the transceiver EEPROM 
        <Condtype> LINE2_TX_BIAS_HIGH_WNG 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline2TrscvWarnDdm 4 }



pmmcAlmLine2TxBiasLowWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 2 Bias Low Warning :Warning 
        indicating that the transceiver 
        laser bias current of Line 2 is 
        lower than the threshold value
         written in the transceiver EEPROM 
        <Condtype> LINE2_TX_BIAS_LOW_WNG 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline2TrscvWarnDdm 3 }



pmmcAlmLine2TxPwrHighWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 2 Tx Power High Warning
         :Warning indicating that the transceiver 
        output power of Line 2 is higher 
        than the threshold value written 
        in the transceiver EEPROM <Condtype> 
        LINE2_TX_PWR_HIGH_WNG <Probcause> 
        transmitterFailure (56) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline2TrscvWarnDdm 2 }



pmmcAlmLine2TxPwLowWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        TRSCV 2 Tx Power Low Warning :Warning 
        indicating that the transceiver 
        output power of Line 2 is lower 
        than the threshold value written 
        in the transceiver EEPROM <Condtype> 
        LINE2_TX_PW_LOW_WNG <Probcause> 
        transmitterFailure (56) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline2TrscvWarnDdm 1 }



--- *****************************************************
---     LEAF for the line2CdrAlm article
--- *****************************************************
pmmcAlmline2CdrAlm OBJECT IDENTIFIER ::= { pmmcAlmLineNurg 31 }




pmmcAlmLine2CdrRefAbsent OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 CDR Reference Clock Absent 
        :This OID indicates that the CDR 
        reference clock is absent on Line 
        2  <Help>  This alarm indicates 
        if the reference clock is present 
        on the line 2 CDR <Condtype> LINE2_CDR_REF_ABSENT 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pmmcAlmline2CdrAlm 3 }



pmmcAlmLine2CdrLossoflock OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 CDR Loss Of Lock :This
         OID indicates that the Line 2
         CDR is not locked  <Help>  This 
        alarm indicates if Line 2 CDR is 
        correclty locked on the input signal 
        <Condtype> LINE2_CDR_LOSSOFLOCK 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmmcAlmline2CdrAlm 2 }



pmmcAlmLine2CdrLossofsignal OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 CDR Loss Of Signal :This 
        OID indicates that a Loss of electrical 
        signal is detected on the Line
         2 CDR  <Help>  This alarm indicates 
        if an electrical signal is detected 
        on the line 2 CDR <Condtype> LINE2_CDR_LOSSOFSIGNAL 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pmmcAlmline2CdrAlm 1 }








--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     CONTROLS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the synth0 article
--- *****************************************************
pmmcCtrlsynth0 OBJECT IDENTIFIER ::= { pmmcCtrlOther 0 }




pmmcCtrlConfClear OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Clear Configuration Tables :This 
        bit clears the configuration tables 
        from configuration in the flash. 
         <Help>  This control restores
         the default configuration of the 
        module
        "
	  ::= { pmmcCtrlsynth0 13 }



pmmcCtrlConfFlash OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Write Configuration Tables :This 
        bit saves the current configuration 
        of the module as configuration
         in the flash.  <Help>  This control 
        saves the customer configuration 
        on the module
        "
	  ::= { pmmcCtrlsynth0 9 }



pmmcCtrlConfLoad OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Load Configuration Tables :When 
        set this enables loading from flash 
        configuration1 into the module.
        "
	  ::= { pmmcCtrlsynth0 1 }



--- *****************************************************
---     LEAF for the synth4 article
--- *****************************************************
pmmcCtrlsynth4 OBJECT IDENTIFIER ::= { pmmcCtrlOther 4 }




pmmcCtrlCorrelatOff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Disable Alarm Correlation :This 
        OID disables the alarm correlation 
        in the PM.
        "
	  ::= { pmmcCtrlsynth4 2 }



pmmcCtrlCorrelatOn OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Enable Alarm Correlation :This 
        OID enables the alarm correlation 
        in the PM.
        "
	  ::= { pmmcCtrlsynth4 1 }



--- *****************************************************
---     LEAF for the swMgnt article
--- *****************************************************
pmmcCtrlswMgnt OBJECT IDENTIFIER ::= { pmmcCtrlOther 5 }




pmmcCtrlWarmReset OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        PM Warm Reset :This OID, when
         set, causes a warm reset of the 
        Software. This reset is not traffic 
        affecting, and the configuration 
        of the Sofwtare remains unchanged. 
         <Help>  This control initiates 
        a warm reset of the module.
        "
	  ::= { pmmcCtrlswMgnt 3 }



pmmcCtrlColdReset OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        PM Cold Reset :This OID, when
         set, causes a cold reset of the 
        Software. This reset is traffic 
        affecting, and the configuration 
        of Software is reloaded on start-up. 
         <Help>  This control initiates 
        a cold reset of the module.
        "
	  ::= { pmmcCtrlswMgnt 2 }



--- *****************************************************
---     LEAF for the line1TrscvOnoff article
--- *****************************************************
pmmcCtrlline1TrscvOnoff OBJECT IDENTIFIER ::= { pmmcCtrlClient 16 }




pmmcCtrlLine1TrscvOnoff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Line 1 SFP Laser Shutdown :This 
        OID switches off the transceiver 
        on Line 1  <Help>  This control 
        defines the laser state of the
         line 1 transceiver
        "
	  ::= { pmmcCtrlline1TrscvOnoff 1 }



--- *****************************************************
---     LEAF for the line2TrscvOnoff article
--- *****************************************************
pmmcCtrlline2TrscvOnoff OBJECT IDENTIFIER ::= { pmmcCtrlLine 24 }




pmmcCtrlLine2TrscvOnoff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Line 2 SFP Laser Shutdown :This 
        OID switches off the transceiver 
        on Line 2  <Help>  This control 
        defines the laser state of the
         line 2 transceiver
        "
	  ::= { pmmcCtrlline2TrscvOnoff 1 }



--- *****************************************************
---     LEAF for the ledTest article
--- *****************************************************
pmmcCtrlledTest OBJECT IDENTIFIER ::= { pmmcCtrlOther 64 }




pmmcCtrlLedOff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Leds Off :This OID switches off 
        all the Leds as a test feature. 
         <Help>  This control initiates 
        a test leds turning all the LEDs 
        to OFF
        "
	  ::= { pmmcCtrlledTest 3 }



pmmcCtrlRedLed OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Red Leds Test :This OID switches 
        on all the red Leds as a test feature. 
         <Help>  This control initiates 
        a test leds turning all the LEDs 
        to red
        "
	  ::= { pmmcCtrlledTest 2 }



pmmcCtrlGreenLed OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Green Leds Test :This OID switches 
        on all the green Leds as a test 
        feature.  <Help>  This control
         initiates a test leds turning
         all the LEDs to green
        "
	  ::= { pmmcCtrlledTest 1 }








--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     MEASURES
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the line1Temperature article
--- *****************************************************

pmmcMesrline1Temperature OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 SFP Temperature :This OID 
        gives the temperature of the transceiver 
        Line 1, read from the DDM (Digital 
        Diagnostic Monitoring) (Temperature 
        = AV/256) (Unit = C)  <Help>  This 
        measure gives the temperature of 
        the line 1 transceiver
        "
	  ::= { pmmcMesrClient 16 }



--- *****************************************************
---     LEAF for the line1Volt article
--- *****************************************************

pmmcMesrline1Volt OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 SFP Power Supply :This
         OID gives the voltage of the transceiver 
        Line 1, read from the DDM (Digital 
        Diagnostic Monitoring) (Voltage 
        = AV/10000) (Unit = V)  <Help>
          This measure gives the 3V3 voltage 
        of the line 1 transceiver
        "
	  ::= { pmmcMesrClient 17 }



--- *****************************************************
---     LEAF for the line1TxBias article
--- *****************************************************

pmmcMesrline1TxBias OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 SFP Laser Bias :This OID 
        gives the bias value of the transceiver 
        Line 1, read from the DDM (Digital 
        Diagnostic Monitoring) (Bias =
         AV/500) (Unit = mA)  <Help>  This 
        measure gives the bias of the line 
        1 transceiver
        "
	  ::= { pmmcMesrClient 18 }



--- *****************************************************
---     LEAF for the line1TxPower article
--- *****************************************************

pmmcMesrline1TxPower OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 SFP Tx Power :This OID
         gives the transmit power value 
        of the transceiver Line 1, read 
        from the DDM (Digital   Diagnostic 
        Monitoring) (Power = 10*log(AV)-40) 
        (Unit = dBm)  <Help>  This measure 
        gives the Tx optical power of the 
        line 1 transceiver
        "
	  ::= { pmmcMesrClient 19 }



--- *****************************************************
---     LEAF for the line1RxPower article
--- *****************************************************

pmmcMesrline1RxPower OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 SFP Rx Power :This OID
         gives the receive power value
         of the transceiver Line 1, read 
        from the DDM (Digital Diagnostic 
        Monitoring) (Power = 10*log(AV)-40) 
        (Unit = dBm)  <Help>  This measure 
        gives the Rx optical power of the 
        line 1 transceiver
        "
	  ::= { pmmcMesrClient 20 }



--- *****************************************************
---     LEAF for the line2Temperature article
--- *****************************************************

pmmcMesrline2Temperature OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 SFP Temperature :This OID 
        gives the temperature of the transceiver 
        Line 2, read from the DDM (Digital 
        Diagnostic Monitoring)  (Temperature 
        = AV/256) (Unit = C)  <Help>  This 
        measure gives the temperature of 
        the line 2 transceiver
        "
	  ::= { pmmcMesrLine 24 }



--- *****************************************************
---     LEAF for the line2Volt article
--- *****************************************************

pmmcMesrline2Volt OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 SFP Power Supply :This
         OID gives the voltage of the transceiver 
        Line 2, read from the DDM (Digital 
        Diagnostic Monitoring) (Voltage 
        = AV/10000) (Unit = V)  <Help>
          This measure gives the 3V3 voltage 
        of the line 2 transceiver
        "
	  ::= { pmmcMesrLine 25 }



--- *****************************************************
---     LEAF for the line2TxBias article
--- *****************************************************

pmmcMesrline2TxBias OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 SFP Laser Bias :This OID 
        gives the bias value of the transceiver 
        Line 2, read from the DDM (Digital 
        Diagnostic Monitoring) (Bias =
         AV/500) (Unit = mA)  <Help>  This 
        measure gives the bias of the line 
        2 transceiver
        "
	  ::= { pmmcMesrLine 26 }



--- *****************************************************
---     LEAF for the line2TxPower article
--- *****************************************************

pmmcMesrline2TxPower OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 SFP Tx Power :This OID
         gives the transmit power value 
        of the transceiver Line 2, read 
        from the DDM (Digital   Diagnostic 
        Monitoring) (Power = 10*log(AV)-40) 
        (Unit = dBm)  <Help>  This measure 
        gives the Tx optical power of the 
        line 2 transceiver
        "
	  ::= { pmmcMesrLine 27 }



--- *****************************************************
---     LEAF for the line2RxPower article
--- *****************************************************

pmmcMesrline2RxPower OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 SFP Rx Power :This OID
         gives the receive power value
         of the transceiver Line 2, read 
        from the DDM (Digital Diagnostic 
        Monitoring) (Power = 10*log(AV)-40) 
        (Unit = dBm)  <Help>  This measure 
        gives the Rx optical power of the 
        line 2 transceiver
        "
	  ::= { pmmcMesrLine 28 }








--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     CONFIG
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the table Group lsd
--- *****************************************************

pmmcCfgLsd OBJECT IDENTIFIER ::= { pmmcConfig 1 }



--- *****************************************************
---     LEAF for the table 0012
--- *****************************************************

pmmctableclientLsd OBJECT IDENTIFIER ::= { pmmcCfgLsd 1 }



pmmcCfglsdMode OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        CAIS mode  on Lines Port :This 
        register selects the way to activate 
        the laser upon CAIS/CSF criteria 
        detection on Port
        "
	  ::= { pmmctableclientLsd 2 }



pmmcCfgline1AccessioCtrb OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        CAIS contributors on Line 1 Port 
        :This register selects the contributors 
        to upstream CAIS/CSF on Port
        "
	  ::= { pmmctableclientLsd 3 }



pmmcCfgline1CdrCtrb OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        CAIS contributors on Line 1 Port 
        :This register selects the contributors 
        to upstream CAIS/CSF on Port
        "
	  ::= { pmmctableclientLsd 4 }



pmmcCfgline2AccessioCtrb OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        CAIS contributors on Line 2 Port 
        :This register selects the contributors 
        to downstream CAIS/CSF on Port
        "
	  ::= { pmmctableclientLsd 5 }



pmmcCfgline2CdrCtrb OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        CAIS contributors on Line 2 Port 
        :This register selects the contributors 
        to downstream CAIS/CSF on Port
        "
	  ::= { pmmctableclientLsd 6 }



--- *****************************************************
---     LEAF for the table Group startUp
--- *****************************************************

pmmcCfgStartUp OBJECT IDENTIFIER ::= { pmmcConfig 2 }



--- *****************************************************
---     LEAF for the table 2111
--- *****************************************************

pmmctableclientStartup OBJECT IDENTIFIER ::= { pmmcCfgStartUp 1 }



pmmcCfgline1TrscvCtrl OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on  Line 1 :This 
         register configures the default 
        initialisation settings on Line 
        1.
        "
	  ::= { pmmctableclientStartup 2 }



--- *****************************************************
---     LEAF for the table 2191
--- *****************************************************

pmmctablelineStartup OBJECT IDENTIFIER ::= { pmmcCfgStartUp 2 }



pmmcCfgline2TrscvCtrl OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Line 2 :This 
         register configures the default 
        initialisation settings on Line 
        2.
        "
	  ::= { pmmctablelineStartup 2 }



pmmcCfgbitrateSelect OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Bitrate selection on Line 1/2
         :This OID register configure the 
        bitrate for the client and line 
        interface (0=STS48 : 2,4 to 2,7 
        Gb/s - 1=1GBE : 1,2 to 1,35 Gb/s 
        - 2=STS12 : 600 to 675 Mb/s - 3=STS3 
        : 150 to 168 Mb/s - 4=2GFC : 2
         to 2,4 Gb/s - 5=1GFC : 1,0 to
         1,2 Gb/s - 6=500 to 600 Mb/s - 
        7=Fast Ethernet : 125 to 150 Mb/s 
        - 8=STS48 + FEC : 2,4-2,7 Gb/s
         - 9=STS12 + FEC : 600-675 Mb/s 
        - 10=STS3 + FEC : 150-168 Mb/s
              ).
        "
	  ::= { pmmctablelineStartup 18 }



--- *****************************************************
---     LEAF for the table Group labels
--- *****************************************************

pmmcCfgLabels OBJECT IDENTIFIER ::= { pmmcConfig 3 }



--- *****************************************************
---     LEAF for the table NO_VALUE
--- *****************************************************

pmmcCfgLabelclientTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PmmcCfgLabelclientEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pmmcCfgLabels 1 }


pmmcCfgLabelclientEntry OBJECT-TYPE
	SYNTAX PmmcCfgLabelclientEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the labels
         table
        "
	INDEX   { pmmcCfgLabelclientIndex }
	::= { pmmcCfgLabelclientTable 1 }


PmmcCfgLabelclientEntry ::=
	SEQUENCE {
	pmmcCfgLabelclientIndex
		INTEGER,
	pmmcCfgLabelclientPortn
		DisplayString
	}


pmmcCfgLabelclientIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the labelclient 
        table
        "
	::= { pmmcCfgLabelclientEntry 1 }


pmmcCfgLabelclientPortn OBJECT-TYPE
	SYNTAX  DisplayString( SIZE(1..16))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default settings on the label
         of the Ports :These registers
         configures the default initialisation 
        settings of the labels of the ports.
        "
	::= { pmmcCfgLabelclientEntry 3 }


--- *****************************************************
---     LEAF for the table NO_VALUE
--- *****************************************************

pmmcCfgLabellineTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PmmcCfgLabellineEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pmmcCfgLabels 2 }


pmmcCfgLabellineEntry OBJECT-TYPE
	SYNTAX PmmcCfgLabellineEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the labels
         table
        "
	INDEX   { pmmcCfgLabellineIndex }
	::= { pmmcCfgLabellineTable 1 }


PmmcCfgLabellineEntry ::=
	SEQUENCE {
	pmmcCfgLabellineIndex
		INTEGER,
	pmmcCfgLabellinePortn
		DisplayString
	}


pmmcCfgLabellineIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the labelline 
        table
        "
	::= { pmmcCfgLabellineEntry 1 }


pmmcCfgLabellinePortn OBJECT-TYPE
	SYNTAX  DisplayString( SIZE(1..16))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default settings on the label
         of the lines :These registers
         configures the default initialisation 
        settings of the labels of the lines.
        "
	::= { pmmcCfgLabellineEntry 3 }



pmmcCfgWriteConfiguration  OBJECT-TYPE
	SYNTAX EkiOnOff
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
	"Write configuration to module:This OID 
	 writes the complete configuration to the module"
	::= { pmmcConfig 257 }






--- *****************************************************
---     TRAP OBJECTS
--- *****************************************************

pmmctrapBoardNumber OBJECT-TYPE
	SYNTAX INTEGER(1..64)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
	"Last module which generates a trap"
	::= { pmmctraps 4 }







--- *****************************************************
---     LINE 1 TRAPS
--- *****************************************************

pmmcLine1TrapNotUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pmmcAlmLine1TrscvDdmWarning, pmmctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMMC Line 1 Not Urgent ON"
	--&ACTIONS     { log, minor }
	--&MATCH       { pmmcAlmLine1TrscvDdmWarning "on", pmmctrapBoardNumber "$2"}
	--&MESG        "DDM Warning appears on Line 1 of PMMC in slot $2 ($A)"
	DESCRIPTION "Not urgent Line 1 default is activated"
	::= { pmmctraps 30 }

pmmcLine1TrapNotUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pmmcAlmLine1TrscvDdmWarning, pmmctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMMC Line 1 Not Urgent OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      {"PMMC Line 1 Not Urgent ON"}
	--&MATCH       { pmmcAlmLine1TrscvDdmWarning "on", pmmctrapBoardNumber "$2"}
	--&MESG        "DDM Warning disappears on Line 1 of PMMC in slot $2 ($A)"
	DESCRIPTION "Not urgent Line 1 default disappeared"
	::= { pmmctraps 31 }

pmmcLine1TrapUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pmmcAlmLine1TrscvDdmAlm, pmmctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMMC Line 1 Urgent ON"
	--&ACTIONS     { log, major }
	--&MATCH       { pmmcAlmLine1TrscvDdmAlm "on", pmmctrapBoardNumber "$2"}
	--&MESG        "DDM Alarm appears on Line 1 of PMMC in slot $2 ($A)"
	DESCRIPTION "Urgent Line 1 default is activated"
	::= { pmmctraps 32 }

pmmcLine1TrapUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pmmcAlmLine1TrscvDdmAlm, pmmctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMMC Line 1 Urgent OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      {"PMMC Line 1 Urgent ON"}
	--&MATCH       { pmmcAlmLine1TrscvDdmAlm "on", pmmctrapBoardNumber "$2"}
	--&MESG        "DDM Alarm disappears on Line 1 of PMMC in slot $2 ($A)"
	DESCRIPTION "Urgent Line 1 default disappeared"
	::= { pmmctraps 33 }

pmmcLine1TrapCritGoesOn NOTIFICATION-TYPE
	OBJECTS {pmmcAlmLine1Fail, pmmcAlmLine1HwFail, pmmctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMMC Line 1 Fail ON"
	--&ACTIONS     { log, critical }
	--&MATCH       { pmmcAlmLine1Fail "on", pmmcAlmLine1HwFail "*", pmmctrapBoardNumber "$3"}
	--&MESG        "Line Port 1 Down on PMMC in Slot $3 ($A)"
	
	--&FILTNAME    "PMMC Line 1 HW Fail ON (Hidden)"
	--&ACTIONS     { info }
	--&MATCH       { pmmcAlmLine1Fail "*", pmmcAlmLine1HwFail "on", pmmctrapBoardNumber "$3"}
	--&MESG        "Line Port 1 Down on PMMC in Slot $3 ($A)"
	DESCRIPTION "Critical Line 1 default is activated"
	::= { pmmctraps 34 }

pmmcLine1TrapCritGoesOff NOTIFICATION-TYPE
	OBJECTS {pmmcAlmLine1Fail, pmmcAlmLine1HwFail, pmmctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMMC Line 1 Fail OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      {"PMMC Line 1 Fail ON"}
	--&MATCH       { pmmcAlmLine1Fail "on", pmmcAlmLine1HwFail "*", pmmctrapBoardNumber "$3"}
	--&MESG        "Line Port 1 Up on PMMC in Slot $3 ($A)"
	
	--&FILTNAME    "PMMC Line 1 HW Fail OFF (Hidden)"
	--&ACTIONS     { info }
	--&MATCH       { pmmcAlmLine1Fail "*", pmmcAlmLine1HwFail "on", pmmctrapBoardNumber "$3"}
	--&MESG        "Line Port 1 Up on PMMC in Slot $3 ($A)"
	DESCRIPTION "Critical Line 1 default disappeared"
	::= { pmmctraps 35 }






--- *****************************************************
---     LINE 2 TRAPS
--- *****************************************************

pmmcLine2NotUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pmmcAlmLine2TrscvDdmWarning, pmmctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMMC Line 2 Not Urgent ON"
	--&ACTIONS     { log, minor }
	--&MATCH       { pmmcAlmLine2TrscvDdmWarning "on", pmmctrapBoardNumber "$2"}
	--&MESG        "DDM Warning appears on Line 2 of PMMC in slot $2 ($A)"
	DESCRIPTION "Not urgent Line 2 default is activated"
	::= { pmmctraps 40 }

pmmcLine2NotUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pmmcAlmLine2TrscvDdmWarning, pmmctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMMC Line 2 Not Urgent OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      {"PMMC Line 2 Not Urgent ON"}
	--&MATCH       { pmmcAlmLine2TrscvDdmWarning "on", pmmctrapBoardNumber "$2"}
	--&MESG        "DDM Warning disappears on Line 2 of PMMC in slot $2 ($A)"
	DESCRIPTION "Not urgent Line 2 default disappeared"
	::= { pmmctraps 41 }

pmmcLine2UrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pmmcAlmLine2TrscvDdmAlm, pmmctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMMC Line 2 Urgent ON"
	--&ACTIONS     { log, major }
	--&MATCH       { pmmcAlmLine2TrscvDdmAlm "on", pmmctrapBoardNumber "$2"}
	--&MESG        "DDM Alarm appears on Line 2 of PMMC in slot $2 ($A)"
	DESCRIPTION "Urgent Line 2 default is activated"
	::= { pmmctraps 42 }

pmmcLine2UrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pmmcAlmLine2TrscvDdmAlm, pmmctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMMC Line 2 Urgent OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      {"PMMC Line 2 Urgent ON"}
	--&MATCH       { pmmcAlmLine2TrscvDdmAlm "on", pmmctrapBoardNumber "$2"}
	--&MESG        "DDM Alarm disappears on Line 2 of PMMC in slot $2 ($A)"
	DESCRIPTION "Urgent Line 2 default disappeared"
	::= { pmmctraps 43 }

pmmcLine2CritGoesOn NOTIFICATION-TYPE
	OBJECTS {pmmcAlmLine2Fail, pmmcAlmLine2HwFail, pmmctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMMC Line 2 Fail ON"
	--&ACTIONS     { log, critical }
	--&MATCH       { pmmcAlmLine2Fail "on", pmmcAlmLine2HwFail "*", pmmctrapBoardNumber "$3"}
	--&MESG        "Line Port 2 Down on PMMC in Slot $3 ($A)"
	
	--&FILTNAME    "PMMC Line 2 HW Fail ON (Hidden)"
	--&ACTIONS     { info }
	--&MATCH       { pmmcAlmLine2Fail "*", pmmcAlmLine2HwFail "on", pmmctrapBoardNumber "$3"}
	--&MESG        "Line Port 2 Down on PMMC in Slot $3 ($A)"
	DESCRIPTION "Critical Line 2 default is activated"
	::= { pmmctraps 44 }

pmmcLine2CritGoesOff NOTIFICATION-TYPE
	OBJECTS {pmmcAlmLine2Fail, pmmcAlmLine2HwFail, pmmctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMMC Line 2 Fail OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      {"PMMC Line 2 Fail ON"}
	--&MATCH       { pmmcAlmLine2Fail "on", pmmcAlmLine2HwFail "*", pmmctrapBoardNumber "$3"}
	--&MESG        "Line Port 2 Up on PMMC in Slot $3 ($A)"
	
	--&FILTNAME    "PMMC Line 2 HW Fail OFF (Hidden)"
	--&ACTIONS     { info }
	--&MATCH       { pmmcAlmLine2Fail "*", pmmcAlmLine2HwFail "on", pmmctrapBoardNumber "$3"}
	--&MESG        "Line Port 2 Up on PMMC in Slot $3 ($A)"
	DESCRIPTION "Critical Line 2 default disappeared"
	::= { pmmctraps 45 }






--- *****************************************************
---     HW TRAPS
--- *****************************************************

pmmcPowerTrapUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pmmcAlmDefFuseB, pmmcAlmDefFuseA , pmmctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMMC Fuse A Fail ON"
	--&ACTIONS     { log, major }
	--&MATCH       { pmmcAlmDefFuseB "*", pmmcAlmDefFuseA "on", pmmctrapBoardNumber "$3"}
	--&MESG        "Power Input A Fail on PMMC in Slot $3 ($A)"

	--&FILTNAME    "PMMC Fuse B Fail ON"
	--&ACTIONS     { log, major }
	--&MATCH       { pmmcAlmDefFuseB "on", pmmcAlmDefFuseA "*", pmmctrapBoardNumber "$3"}
	--&MESG        "Power Input B Fail on PMMC in Slot $3 ($A)"
	DESCRIPTION "Urgent power supply default is activated"
	::= { pmmctraps 50 }
pmmcPowerTrapUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pmmcAlmDefFuseB, pmmcAlmDefFuseA , pmmctrapBoardNumber}
	STATUS current
	--&FILTNAME    "PMMC Fuse A&B Fail OFF"
	--&ACTIONS     { log, normal}
	--&CLEARS      { "PMMC Fuse A Fail ON", "PMMC Fuse B Fail ON" }
	--&MATCH       { pmmcAlmDefFuseB "on", pmmcAlmDefFuseA "on", pmmctrapBoardNumber "$3"}
	--&MESG        "Power Inputs A and B Present on PMMC in Slot $3 ($A)"
	DESCRIPTION "Urgent power supply default disappeared"
	::= { pmmctraps 51 }






END