-- EKINOPS-Pm801RR.TXT:  MIB
--
--MIB Part Number:3MI00101ACAD
--MIB Version:02
--
-- Copyright (c) 2016 by Ekinops
-- All rights reserved.
-- 
-- *****************************************************************

EKINOPS-Pm801RR-MIB DEFINITIONS ::= BEGIN

IMPORTS
	ekinops,
	EkiState,
	EkiOnOff,
	EkiMode,
	EkiProtocol,
	EkiApiState,
	EkiSynchroMode,
	EkiMeasureType
			FROM EKINOPS-MIB
        MODULE-IDENTITY,
        OBJECT-TYPE,
        NOTIFICATION-TYPE,
	Unsigned32,
	Integer32,
	Counter32,
	IpAddress                
        		FROM SNMPv2-SMI
 	TEXTUAL-CONVENTION,
	DisplayString
                FROM SNMPv2-TC;

modulePm801RR MODULE-IDENTITY
        LAST-UPDATED "201606070000Z"
        ORGANIZATION "Ekinops"
        CONTACT-INFO
         "Ekinops

          3, rue Blaise Pascal
          F-22300 Lannion / FRANCE

          Tel : +33 (0)2 96 05 00 30
          Fax : +33 (0)2 96 48 62 39

          E-mail: support@ekinops.net"
        DESCRIPTION
          "MIB for the Ekinops Pm801RR hardware."
	REVISION "201008260000Z"
	DESCRIPTION
	  "Initial Version."

	REVISION "201008260000Z"
	DESCRIPTION
	  "Creation"
	REVISION "201011030000Z"
	DESCRIPTION
	  "Formula in comments, Event on XFP init"
	REVISION "201207040000Z"
	DESCRIPTION
	  "Minor cosmetic updates"
	REVISION "201403250000Z"
	DESCRIPTION
	  "Probcause,AlarmType - NMS completion"
	REVISION "201412090000Z"
	DESCRIPTION
	  "Labels cosmetic updates"
	REVISION "201605230000Z"
	DESCRIPTION
	  "New AlarmType  synthesisAlarm (12)"
	REVISION "201606070000Z"
	DESCRIPTION
	  "Capabilities objects of Table 5"
        ::= { ekinops 48 }



--- *****************************************************
---     LEAF LEVEL 2
--- *****************************************************


pm801rralarms OBJECT IDENTIFIER ::= { modulePm801RR 2 }	
pm801rrAlmOther OBJECT IDENTIFIER ::= { pm801rralarms 1 }
pm801rrAlmOtherNurg OBJECT IDENTIFIER ::= { pm801rrAlmOther 1 }
pm801rrAlmOtherUrg OBJECT IDENTIFIER ::= { pm801rrAlmOther 2 }
pm801rrAlmOtherCrit OBJECT IDENTIFIER ::= { pm801rrAlmOther 3 }

pm801rrAlmClient OBJECT IDENTIFIER ::= { pm801rralarms 2 }
pm801rrAlmClientNurg OBJECT IDENTIFIER ::= { pm801rrAlmClient 1 }
pm801rrAlmClientUrg OBJECT IDENTIFIER ::= { pm801rrAlmClient 2 }
pm801rrAlmClientCrit OBJECT IDENTIFIER ::= { pm801rrAlmClient 3 }
	
pm801rrAlmLine OBJECT IDENTIFIER ::= { pm801rralarms 3 }
pm801rrAlmLineNurg OBJECT IDENTIFIER ::= { pm801rrAlmLine 1 }
pm801rrAlmLineUrg OBJECT IDENTIFIER ::= { pm801rrAlmLine 2 }
pm801rrAlmLineCrit OBJECT IDENTIFIER ::= { pm801rrAlmLine 3 }


pm801rrmeasures OBJECT IDENTIFIER ::= { modulePm801RR 3 }	
pm801rrMesrOther OBJECT IDENTIFIER ::= { pm801rrmeasures 1 }	
pm801rrMesrClient OBJECT IDENTIFIER ::= { pm801rrmeasures 2 }	
pm801rrMesrLine OBJECT IDENTIFIER ::= { pm801rrmeasures 3 }	


pm801rrcontrolsWrite OBJECT IDENTIFIER ::= { modulePm801RR 6 }
pm801rrCtrlOther OBJECT IDENTIFIER ::= { pm801rrcontrolsWrite 1 }
pm801rrCtrlClient OBJECT IDENTIFIER ::= { pm801rrcontrolsWrite 2 }
pm801rrCtrlLine OBJECT IDENTIFIER ::= { pm801rrcontrolsWrite 3 }

pm801rrri OBJECT IDENTIFIER ::= { modulePm801RR 7 }


pm801rrConfig OBJECT IDENTIFIER ::= { modulePm801RR 9 }

pm801rrtraps OBJECT IDENTIFIER ::= { modulePm801RR 10 }


--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     TEXTUAL-CONVENTION
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************

Pm801rrBitRate ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION "different rates for a client and line ports"
    SYNTAX INTEGER {
		rateOC192(0),
		rate10GBELAN(1),
		rate10GBEWAN(2),
		rate10GFC(3),
		rate10FECG975(4),
		rate10FECG709(5)
           }

Pm801rrOtxMode ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION "Different modes on OTX-TLH on client and line ports"
    SYNTAX INTEGER {
		otx80mode(1),
		otx60mode(2),
		otxadjustmode(4)
           }

Pm801rrOtxGrid ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION "Different grids on OTX-TLH on client and line ports"
    SYNTAX INTEGER {
		otxgrid200(200),
		otxgrid100(100),
		otxgrid50(50)
           }

Pm801rrAdjustValue ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION "Different values in Adjust mode on OTX-TLH on client and line ports"
    SYNTAX INTEGER {
		otxadjustvalue0(0),
		otxadjustvalue1(1),
		otxadjustvalue2(2),
		otxadjustvalue3(3),
		otxadjustvalue4(4),
		otxadjustvalue5(5),
		otxadjustvalue6(6),
		otxadjustvalue7(7),
		otxadjustvalue8(8),
		otxadjustvalue9(9),
		otxadjustvalue10(10)
           }

Pm801rrOtxChannel ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION "Channel selection on OTX-TLH on client and line ports"
    SYNTAX INTEGER 


--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     REMOTE INVENTORY
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************

pm801rrRinvReloadInventory OBJECT-TYPE
  SYNTAX EkiOnOff
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION
        "Reload the inventory: This OID triggers an 
         inventory reload."
  ::= { pm801rrri 2 }

  
pm801rrRinvHwPlatform OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
        "Module platform description: This OID contains the 
         description of the Module."
  ::= { pm801rrri 4 }
  
pm801rrRinvSwPlatform OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
        "SW platform description: This OID contains the 
         description of the Software platform."
  ::= { pm801rrri 5 }
  
pm801rrRinvClientXFP OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
        "Inventory for the XFP: This OID contains the inventory for the Client XFP"
  ::= { pm801rrri 6 }


pm801rrRinvLineXFP OBJECT-TYPE
  SYNTAX DisplayString
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
        "Inventory for the XFP: This OID contains the inventory for the Line XFP"
  ::= { pm801rrri 7 }






--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     ALARMS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the synthAlm0 article
--- *****************************************************
pm801rrAlmsynthAlm0 OBJECT IDENTIFIER ::= { pm801rrAlmOtherCrit 0 }




pm801rrAlmDefFuseB OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Fuse B Fail :This OID indicates 
        that the fuse of the power input 
        B is in fail condition  <Help>
          Status of the Fuse B <Condtype> 
        DEF_FUSE_B <Probcause> powerProblem 
        (36) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmsynthAlm0 16 }



pm801rrAlmDefFuseA OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Fuse A Fail :This OID indicates 
        that the fuse of the power input 
        A is in fail condition  <Help>
          Status of the Fuse A <Condtype> 
        DEF_FUSE_A <Probcause> powerProblem 
        (36) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmsynthAlm0 15 }



pm801rrAlmModuleGlobFailure OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Module Failure :This OID is set 
        on detection of a failure originating 
        from the PM <Condtype> MODULE_GLOB_FAILURE 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	  ::= { pm801rrAlmsynthAlm0 9 }



--- *****************************************************
---     LEAF for the synthAlm7 article
--- *****************************************************
pm801rrAlmsynthAlm7 OBJECT IDENTIFIER ::= { pm801rrAlmLineCrit 7 }




pm801rrAlmLineVccAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 VCC Alarm :This OID indicates 
        an overall VCC alarm is set over 
        the Line 2 XFP <Condtype> LINE_VCC_ALARM 
        <Probcause> powerProblem (36) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmsynthAlm7 15 }



pm801rrAlmLineVccWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 VCC Warning :This OID indicates 
        an overall VCC warning is set over 
        the Line 2 XFP <Condtype> LINE_VCC_WARNING 
        <Probcause> powerProblem (36) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmsynthAlm7 14 }



pm801rrAlmLineFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Port Failure :This OID
         indicates a failure on the Line 
        2 port <Condtype> LINE_FAIL <Probcause> 
        equipmentMalfunction (16) <Alarmtype> 
        synthesisAlarm (12)  <Polarity> 
        (2) 
        "
	  ::= { pm801rrAlmsynthAlm7 12 }



pm801rrAlmLineDdmAlm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Alarm On Line 2 Optical Module 
        DDM :This OID indicates an alarm 
        is present coming out of Line 2 
        optical interface DDM  <Help> 
         This alarm indicates if a DDM
         Alarm has been detected on the 
        line 2 transceiver <Condtype> LINE_DDM_ALM 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	  ::= { pm801rrAlmsynthAlm7 10 }



pm801rrAlmLineDdmWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Warning On Line 2 Optical Module 
        DDM :This OID indicates a warning 
        is present coming out of Line 2 
        optical interface DDM  <Help> 
         This alarm indicates if a DDM
         Warning has been detected on the 
        line 2 transceiver <Condtype> LINE_DDM_WARNING 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	  ::= { pm801rrAlmsynthAlm7 9 }



pm801rrAlmLineXfpTxOff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Optical Module Laser Shutdown 
        :This OID indicates the Line 2
         optical output power is off  <Help> 
         This status indicates if the line 
        2 transceiver laser is ON or OFF 
        <Condtype> LINE_XFP_TX_OFF <Probcause> 
        other (1) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmsynthAlm7 5 }



pm801rrAlmLineHwFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Port HW Failure :This OID 
        indicates a failure on Line 2 port, 
        most probably caused by a HW issue 
        <Condtype> LINE_HW_FAIL <Probcause> 
        equipmentMalfunction (16) <Alarmtype> 
        synthesisAlarm (12)  <Polarity> 
        (2) 
        "
	  ::= { pm801rrAlmsynthAlm7 4 }



pm801rrAlmLineInitNotCompl OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Optical Module Ready :This 
        OID indicates the optical interface 
        (XFP or OTX) is not operational
 
         <Help>  This status indicates
         if the line 2 transceiver has
         been correctly initialized <Condtype> 
        LINE_INIT_NOT_COMPL <Probcause> 
        equipmentMalfunction (16) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        <Event> ObjectCDINV
        "
	  ::= { pm801rrAlmsynthAlm7 2 }



pm801rrAlmLineXfpAbsent OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Optical Module Absent :This 
        OID indicates the Line 2 optical 
        interface (XFP or OTX) is not present 
        in the PM  <Help>  This alarm indicates 
        if the line 2 transceiver is present. 
        <Condtype> LINE_XFP_ABSENT <Probcause> 
        inputOutputDeviceError (24) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        <Event> ObjectCDINV
        "
	  ::= { pm801rrAlmsynthAlm7 1 }



--- *****************************************************
---     LEAF for the synthAlm8 article
--- *****************************************************
pm801rrAlmsynthAlm8 OBJECT IDENTIFIER ::= { pm801rrAlmClientCrit 8 }




pm801rrAlmClientVccAlarm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 VCC Alarm :This OID indicates 
        an overall VCC alarm is set over 
        the Line 1 XFP <Condtype> CLIENT_VCC_ALARM 
        <Probcause> powerProblem (36) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmsynthAlm8 15 }



pm801rrAlmClientVccWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1VCC Warning :This OID indicates 
        an overall VCC warning is set over 
        the Line 1 XFP <Condtype> CLIENT_VCC_WARNING 
        <Probcause> powerProblem (36) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmsynthAlm8 14 }



pm801rrAlmClientFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Port Failure :This OID
         indicates a failure on the Line 
        1 port <Condtype> CLIENT_FAIL <Probcause> 
        equipmentMalfunction (16) <Alarmtype> 
        synthesisAlarm (12)  <Polarity> 
        (2) 
        "
	  ::= { pm801rrAlmsynthAlm8 12 }



pm801rrAlmClientDdmAlm OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Alarm On Line 1 Optical Module 
        DDM :This OID indicates an alarm 
        is present coming out of Line 1 
        optical interface DDM  <Help> 
         This alarm indicates if a DDM
         Alarm has been detected on the 
        line 1 transceiver <Condtype> CLIENT_DDM_ALM 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	  ::= { pm801rrAlmsynthAlm8 10 }



pm801rrAlmClientDdmWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Warning On Line 1 Optical Module 
        DDM :This OID indicates a warning 
        is present coming out of Line 1 
        optical interface DDM  <Help> 
         This alarm indicates if a DDM
         Warning has been detected on the 
        line 1 transceiver <Condtype> CLIENT_DDM_WARNING 
        <Probcause> equipmentMalfunction 
        (16) <Alarmtype> synthesisAlarm 
        (12)  <Polarity> (2) 
        "
	  ::= { pm801rrAlmsynthAlm8 9 }



pm801rrAlmClientXfpTxOff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Optical Module Laser Shutdown 
        :This OID indicates the Line 1
         optical output power is off  <Help> 
         This status indicates if the line 
        1 transceiver laser is ON or OFF 
        <Condtype> CLIENT_XFP_TX_OFF <Probcause> 
        other (1) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmsynthAlm8 5 }



pm801rrAlmClientHwFail OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Port HW Failure :This OID 
        indicates a failure on Line 1 port, 
        most probably caused by a HW issue. 
        <Condtype> CLIENT_HW_FAIL <Probcause> 
        equipmentMalfunction (16) <Alarmtype> 
        synthesisAlarm (12)  <Polarity> 
        (2) 
        "
	  ::= { pm801rrAlmsynthAlm8 4 }



pm801rrAlmClientInitNotCompl OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Optical Module Ready :This 
        OID indicates the optical interface 
        (XFP or OTX) is not operational
 
         <Help>  This status indicates
         if the line 1 transceiver has
         been correctly initialized <Condtype> 
        CLIENT_INIT_NOT_COMPL <Probcause> 
        equipmentMalfunction (16) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        <Event> ObjectCDINV
        "
	  ::= { pm801rrAlmsynthAlm8 2 }



pm801rrAlmClientXfpAbsent OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Optical Module Absent :This 
        OID indicates the Line 1 optical 
        interface (XFP or OTX) is not present 
        in the PM  <Help>  This alarm indicates 
        if the line 1 transceiver is present. 
        <Condtype> CLIENT_XFP_ABSENT <Probcause> 
        inputOutputDeviceError (24) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        <Event> ObjectCDINV
        "
	  ::= { pm801rrAlmsynthAlm8 1 }



--- *****************************************************
---     LEAF for the clientXfpAlarm1 article
--- *****************************************************
pm801rrAlmclientXfpAlarm1 OBJECT IDENTIFIER ::= { pm801rrAlmClientUrg 16 }




pm801rrAlmClientRxPwrHighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Optical Rx Power High :Alarm 
        indicating that the Line 1 XFP/OTX 
        received optical power is higher 
        than the threshold value written 
        in the Line 1 XFP/OTX EEPROM <Condtype> 
        CLIENT_RX_PWR_HIGH_ALA <Probcause> 
        receiveFailure (41) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientXfpAlarm1 16 }



pm801rrAlmClientRxPwrLowAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Optical Rx Power Low :Alarm 
        indicating that the Line 1 XFP/OTX 
        received optical power is lower 
        than the threshold value written 
        in the Line 1 XFP/OTX EEPROM  <Condtype> 
        CLIENT_RX_PWR_LOW_ALA <Probcause> 
        receiveFailure (41) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientXfpAlarm1 15 }



pm801rrAlmClientTempHighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Transceiver Temp High :Alarm 
        indicating that the Line 1 XFP/OTX 
        temperature is higher than the
         threshold value written in the 
        Line 1 XFP/OTX EEPROM <Condtype> 
        CLIENT_TEMP_HIGH_ALA <Probcause> 
        temperatureUnacceptable (51) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientXfpAlarm1 8 }



pm801rrAlmClientTempLowAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Transceiver Temp Low :Alarm 
        indicating that the Line 1 XFP/OTX 
        temperature is lower than the threshold 
        value written in the Line 1 XFP/OTX 
        EEPROM <Condtype> CLIENT_TEMP_LOW_ALA 
        <Probcause> temperatureUnacceptable 
        (51) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientXfpAlarm1 7 }



pm801rrAlmClientTxBiasHighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Transceiver Bias High :Alarm 
        indicating that the Line 1 XFP/OTX 
        transmitter laser bias current
         is higher than the threshold value 
        written in the Line 1 XFP/OTX EEPROM 
        <Condtype> CLIENT_TX_BIAS_HIGH_ALA 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientXfpAlarm1 4 }



pm801rrAlmClientTxBiasLowAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Transceiver Bias Low :Alarm 
        indicating that the Line 1 XFP/OTX 
        transmitter laser bias current
         is lower than the threshold value 
        written in the Line 1 XFP/OTX EEPROM 
        <Condtype> CLIENT_TX_BIAS_LOW_ALA 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientXfpAlarm1 3 }



pm801rrAlmClientTxPwrHighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Optical Tx Power High :Alarm 
        indicating that the Line 1 XFP/OTX 
        transmitter transmitter output
         power is higher than the threshold 
        value written in the Line 1 XFP/OTX 
        EEPROM <Condtype> CLIENT_TX_PWR_HIGH_ALA 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientXfpAlarm1 2 }



pm801rrAlmClientTxPwrLowAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Optical Tx Power Low :Alarm 
        indicating that the Line 1 XFP/OTX 
        transmitter transmitter output
         power is lower than the threshold 
        value written in the Line 1 XFP/OTX 
        EEPROM <Condtype> CLIENT_TX_PWR_LOW_ALA 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientXfpAlarm1 1 }



--- *****************************************************
---     LEAF for the clientXfpWarnings article
--- *****************************************************
pm801rrAlmclientXfpWarnings OBJECT IDENTIFIER ::= { pm801rrAlmClientNurg 17 }




pm801rrAlmClientRxPwrHighWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Optical Rx Power High Warning 
        :Warning indicating that the Line 
        1 XFP/OTX received optical power 
        is higher than the threshold value 
        written in the Line 1 XFP/OTX EEPROM 
        <Condtype> CLIENT_RX_PWR_HIGH_WNG 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientXfpWarnings 16 }



pm801rrAlmClientRxPwrLowWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Optical Rx Power Low Warning 
        :Warning indicating that the Line 
        1 XFP/OTX received optical power 
        is lower than the threshold value 
        written in the Line 1 XFP/OTX EEPROM 
         <Condtype> CLIENT_RX_PWR_LOW_WNG 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientXfpWarnings 15 }



pm801rrAlmClientTempHighWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Transceiver Temp High Warning 
        :Warning indicating that the Line 
        1 XFP/OTX temperature is higher 
        than the threshold value written 
        in the Line 1 XFP/OTX EEPROM <Condtype> 
        CLIENT_TEMP_HIGH_WNG <Probcause> 
        temperatureUnacceptable (51) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientXfpWarnings 8 }



pm801rrAlmClientTempLowWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Transceiver Temp Low Warning 
        :Warning indicating that the Line 
        1 XFP/OTX temperature is lower
         than the threshold value written 
        in the Line 1 XFP/OTX EEPROM <Condtype> 
        CLIENT_TEMP_LOW_WNG <Probcause> 
        temperatureUnacceptable (51) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientXfpWarnings 7 }



pm801rrAlmClientTxBiasHighWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Transceiver Bias High Warning 
        :Warning indicating that the Line 
        1 XFP/OTX transmitter laser bias 
        current is higher than the threshold 
        value written in the Line 1 XFP/OTX 
        EEPROM <Condtype> CLIENT_TX_BIAS_HIGH_WNG 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientXfpWarnings 4 }



pm801rrAlmClientTxBiasLowWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Transceiver Bias Low Warning 
        :Warning indicating that the Line 
        1 XFP/OTX transmitter laser bias 
        current is lower than the threshold 
        value written in the Line 1 XFP/OTX 
        EEPROM <Condtype> CLIENT_TX_BIAS_LOW_WNG 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientXfpWarnings 3 }



pm801rrAlmClientTxPwrHighWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Optical Tx Power High Warning 
        :Warning indicating that the Line 
        1 XFP/OTX transmitter transmitter 
        output power is higher than the 
        threshold value written in the
         Line 1 XFP/OTX EEPROM <Condtype> 
        CLIENT_TX_PWR_HIGH_WNG <Probcause> 
        transmitterFailure (56) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientXfpWarnings 2 }



pm801rrAlmClientTxPwrLowWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Optical Tx Power Low Warning 
        :Warning indicating that the Line 
        1 XFP/OTX transmitter transmitter 
        output power is lower than the
         threshold value written in the 
        Line 1 XFP/OTX EEPROM <Condtype> 
        CLIENT_TX_PWR_LOW_WNG <Probcause> 
        transmitterFailure (56) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientXfpWarnings 1 }



--- *****************************************************
---     LEAF for the clientXfpAlarms2 article
--- *****************************************************
pm801rrAlmclientXfpAlarms2 OBJECT IDENTIFIER ::= { pm801rrAlmClientCrit 19 }




pm801rrAlmClientApdSupplyFault OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Rx Photodiode Power Failed 
        :This OID indicates a failure on 
        the Line 1 APD power supply <Condtype> 
        CLIENT_APD_SUPPLY_FAULT <Probcause> 
        receiverFailure (42) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientXfpAlarms2 16 }



pm801rrAlmClientTecFault OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Optical Tx Temp Regul.
         Failed :This OID indicates a failure 
        on the Line 1 TEC module <Condtype> 
        CLIENT_TEC_FAULT <Probcause> transmitterFailure 
        (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientXfpAlarms2 15 }



pm801rrAlmClientWavelengthUnlocked OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Optical Tx Wavelength Unlocked 
        :This OID indicates that the Line 
        1 wavelength error is exceeding 
        the manufacturer tolerance <Condtype> 
        CLIENT_WAVELENGTH_UNLOCKED <Probcause> 
        transmitterFailure (56) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientXfpAlarms2 14 }



pm801rrAlmClientChannelNotAcquired OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 DWDM Channel Not Acquired 
        :This OID indicates the transceiver 
        didn't tune the DWDM Channel succesfully. 
         <Help>  This status indicates
         the transceiver has not tuned
         the DWDM Channel succesfully.
         <Condtype> CLIENT_CHANNEL_NOT_ACQUIRED 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientXfpAlarms2 10 }



pm801rrAlmClientTxNr OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Optical Tx Not Ready :This 
        OID indicates a condition has arisen 
        leading to invalid data on the
         Line 1 transmitting side <Condtype> 
        CLIENT_TX_NR <Probcause> transmitterFailure 
        (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientXfpAlarms2 8 }



pm801rrAlmClientTxFault OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Optical Tx Failure :This 
        OID indicates a fault condition 
        on the Line 1 laser detected by 
        the safety syste <Condtype> CLIENT_TX_FAULT 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientXfpAlarms2 7 }



pm801rrAlmClientTxCdrNotLocked OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Optical Tx CDR Unlocked 
        :This OID indicates a loss of lock 
        on the Line 1 transmitting side 
        CDR has been detected. <Condtype> 
        CLIENT_TX_CDR_NOT_LOCKED <Probcause> 
        transmitterFailure (56) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientXfpAlarms2 6 }



pm801rrAlmClientRxNr OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Optical Rx Not Ready :This 
        OID indicates that a condition
         has arisen leading to invalid
         data on the Line 1 receiving side. 
        <Condtype> CLIENT_RX_NR <Probcause> 
        receiveFailure (41) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientXfpAlarms2 5 }



pm801rrAlmClientRxLos OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Loss Of Optical Signal
         :This bit indicates an absence 
        of signal on the XFP/OTX  <Help> 
         This alarm indicates if an optical 
        signal is detected on the line
         1 transceiver input <Condtype> 
        CLIENT_RX_LOS <Probcause> receiveFailure 
        (41) <Alarmtype> physicalViolation 
        (9) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientXfpAlarms2 4 }



pm801rrAlmClientRxCdrNotLocked OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Optical Rx CDR Unlocked 
        :This OID indicates that a loss 
        of lock on the Line 1 receiving 
        side CDR has been detected <Condtype> 
        CLIENT_RX_CDR_NOT_LOCKED <Probcause> 
        receiveFailure (41) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientXfpAlarms2 3 }



pm801rrAlmClientResetComplete OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Not Used :This bit indicates that 
        the internal reset process is completed 
        and the data are available <Condtype> 
        CLIENT_RESET_COMPLETE <Probcause> 
        other (1) <Alarmtype> other (1) 
        <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientXfpAlarms2 1 }



--- *****************************************************
---     LEAF for the clientOtxTlhAlarms3 article
--- *****************************************************
pm801rrAlmclientOtxTlhAlarms3 OBJECT IDENTIFIER ::= { pm801rrAlmClientUrg 22 }




pm801rrAlmClientLaserTempHighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Laser Temp. High Alarm
         :Alarm indicating the Line 1 OTX 
        TLH laser temperature is higher 
        than the threshold written in the 
        EEPROM <Condtype> CLIENT_LASER_TEMP_HIGH_ALA 
        <Probcause> temperatureUnacceptable 
        (51) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientOtxTlhAlarms3 14 }



pm801rrAlmClientFreqDevHighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Freq. Deviation High Alarm 
        :Alarm indicating the Line 1 OTX 
        TLH frequency deviation is higher 
        than the threshold written in the 
        EEPROM <Condtype> CLIENT_FREQ_DEV_HIGH_ALA 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientOtxTlhAlarms3 12 }



pm801rrAlmClientCdrNotReady OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 CDR Not Ready :This OID 
        indicates the Clock Data Recovery 
        unit is not yet initialized   
         <Help>   This alarm indicates
         the Clock Data Recovery unit is 
        not yet initialized. <Condtype> 
        CLIENT_CDR_NOT_READY <Probcause> 
        receiveFailure (41) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientOtxTlhAlarms3 9 }



pm801rrAlmClientAgingHighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 OTX TLH Aging High Alarm 
        :Alarm indicating the Line 1 OTX 
        TLH aging is higher than the threshold 
        written in the EEPROM <Condtype> 
        CLIENT_AGING_HIGH_ALA <Probcause> 
        transmitterFailure (56) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientOtxTlhAlarms3 6 }



pm801rrAlmClientModulatorAgingHighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Modulator Aging High Alarm 
        :Alarm indicating the Line 1 OTX 
        TLH modulator aging is higher than 
        the threshold written in the EEPROM 
        <Condtype> CLIENT_MODULATOR_AGING_HIGH_ALA 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientOtxTlhAlarms3 5 }



--- *****************************************************
---     LEAF for the clientOtxTlhWarnings article
--- *****************************************************
pm801rrAlmclientOtxTlhWarnings OBJECT IDENTIFIER ::= { pm801rrAlmClientNurg 23 }




pm801rrAlmClientLaserTempHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Laser Temp. High Warning 
        :Warning indicating the Line 1
         OTX TLH laser temperature is higher 
        than the threshold written in the 
        EEPROM <Condtype> CLIENT_LASER_TEMP_HIGH_WARNING 
        <Probcause> temperatureUnacceptable 
        (51) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientOtxTlhWarnings 14 }



pm801rrAlmClientFreqDevHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Freq. Deviation High Warning 
        :Warning indicating the Line 1
         OTX TLH frequency deviation is 
        higher than the threshold written 
        in the EEPROM <Condtype> CLIENT_FREQ_DEV_HIGH_WARNING 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientOtxTlhWarnings 12 }



pm801rrAlmClientAgingHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 OTX TLH Aging High Warning 
        :Warning indicating the Line 1
         OTX TLH aging is higher than the 
        threshold written in the EEPROM 
        <Condtype> CLIENT_AGING_HIGH_WARNING 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientOtxTlhWarnings 6 }



pm801rrAlmClientModulatorAgingHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Modulator Aging High Warning 
        :Warning indicating the Line 1
         OTX TLH modulator aging is higher 
        than the threshold written in the 
        EEPROM <Condtype> CLIENT_MODULATOR_AGING_HIGH_WARNING 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmclientOtxTlhWarnings 5 }



--- *****************************************************
---     LEAF for the lineXfpAlarm1 article
--- *****************************************************
pm801rrAlmlineXfpAlarm1 OBJECT IDENTIFIER ::= { pm801rrAlmLineUrg 24 }




pm801rrAlmLineRxPwrHighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Optical Rx Power High :Alarm 
        indicating that the Line 2 XFP/OTX 
        received optical power is higher 
        than the threshold value written 
        in the Line 2 XFP/OTX EEPROM <Condtype> 
        LINE_RX_PWR_HIGH_ALA <Probcause> 
        receiveFailure (41) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmlineXfpAlarm1 16 }



pm801rrAlmLineRxPwrLowAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Optical Rx Power Low :Alarm 
        indicating that the Line 2 XFP/OTX 
        received optical power is lower 
        than the threshold value written 
        in the Line 2 XFP/OTX EEPROM  <Condtype> 
        LINE_RX_PWR_LOW_ALA <Probcause> 
        receiveFailure (41) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmlineXfpAlarm1 15 }



pm801rrAlmLineTempHighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Transceiver Temp High :Alarm 
        indicating that the Line 2 XFP/OTX 
        temperature is higher than the
         threshold value written in the 
        Line 2 XFP/OTX EEPROM <Condtype> 
        LINE_TEMP_HIGH_ALA <Probcause>
         temperatureUnacceptable (51) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmlineXfpAlarm1 8 }



pm801rrAlmLineTempLowAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Transceiver Temp Low :Alarm 
        indicating that the Line 2 XFP/OTX 
        temperature is lower than the threshold 
        value written in the Line 2 XFP/OTX 
        EEPROM <Condtype> LINE_TEMP_LOW_ALA 
        <Probcause> temperatureUnacceptable 
        (51) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmlineXfpAlarm1 7 }



pm801rrAlmLineTxBiasHighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Transceiver Bias High :Alarm 
        indicating that the Line 2 XFP/OTX 
        transmitter laser bias current
         is higher than the threshold value 
        written in the Line 2 XFP/OTX EEPROM 
        <Condtype> LINE_TX_BIAS_HIGH_ALA 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmlineXfpAlarm1 4 }



pm801rrAlmLineTxBiasLowAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Transceiver Bias Low :Alarm 
        indicating that the Line 2 XFP/OTX 
        transmitter laser bias current
         is lower than the threshold value 
        written in the Line 2 XFP/OTX EEPROM 
        <Condtype> LINE_TX_BIAS_LOW_ALA 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmlineXfpAlarm1 3 }



pm801rrAlmLineTxPwrHighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Optical Tx Power High :Alarm 
        indicating that the Line 2 XFP/OTX 
        transmitter transmitter output
         power is higher than the threshold 
        value written in the Line 2 XFP/OTX 
        EEPROM <Condtype> LINE_TX_PWR_HIGH_ALA 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmlineXfpAlarm1 2 }



pm801rrAlmLineTxPwrLowAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Optical Tx Power Low :Alarm 
        indicating that the Line 2 XFP/OTX 
        transmitter transmitter output
         power is lower than the threshold 
        value written in the Line 2 XFP/OTX 
        EEPROM <Condtype> LINE_TX_PWR_LOW_ALA 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmlineXfpAlarm1 1 }



--- *****************************************************
---     LEAF for the lineXfpWarnings article
--- *****************************************************
pm801rrAlmlineXfpWarnings OBJECT IDENTIFIER ::= { pm801rrAlmLineNurg 25 }




pm801rrAlmLineRxPwrHighWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Optical Rx Power High Warning 
        :Warning indicating that the Line 
        2 XFP/OTX received optical power 
        is higher than the threshold value 
        written in the Line 2 XFP/OTX EEPROM 
        <Condtype> LINE_RX_PWR_HIGH_WNG 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pm801rrAlmlineXfpWarnings 16 }



pm801rrAlmLineRxPwrLowWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Optical Rx Power Low Warning 
        :Warning indicating that the Line 
        2 XFP/OTX received optical power 
        is lower than the threshold value 
        written in the Line 2 XFP/OTX EEPROM 
         <Condtype> LINE_RX_PWR_LOW_WNG 
        <Probcause> receiveFailure (41) 
        <Alarmtype> equipmentAlarm (5)
         <Polarity> (2) 
        "
	  ::= { pm801rrAlmlineXfpWarnings 15 }



pm801rrAlmLineTempHighWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Transceiver Temp High Warning 
        :Warning indicating that the Line 
        2 XFP/OTX temperature is higher 
        than the threshold value written 
        in the Line 2 XFP/OTX EEPROM <Condtype> 
        LINE_TEMP_HIGH_WNG <Probcause>
         temperatureUnacceptable (51) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmlineXfpWarnings 8 }



pm801rrAlmLineTempLowWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Transceiver Temp Low Warning 
        :Warning indicating that the Line 
        2 XFP/OTX temperature is lower
         than the threshold value written 
        in the Line 2 XFP/OTX EEPROM <Condtype> 
        LINE_TEMP_LOW_WNG <Probcause> temperatureUnacceptable 
        (51) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmlineXfpWarnings 7 }



pm801rrAlmLineTxBiasHighWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Transceiver Bias High Warning 
        :Warning indicating that the Line 
        2 XFP/OTX transmitter laser bias 
        current is higher than the threshold 
        value written in the Line 2 XFP/OTX 
        EEPROM <Condtype> LINE_TX_BIAS_HIGH_WNG 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmlineXfpWarnings 4 }



pm801rrAlmLineTxBiasLowWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Transceiver Bias Low Warning 
        :Warning indicating that the Line 
        2 XFP/OTX transmitter laser bias 
        current is lower than the threshold 
        value written in the Line 2 XFP/OTX 
        EEPROM <Condtype> LINE_TX_BIAS_LOW_WNG 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmlineXfpWarnings 3 }



pm801rrAlmLineTxPwrHighWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Optical Tx Power High Warning 
        :Warning indicating that the Line 
        2 XFP/OTX transmitter transmitter 
        output power is higher than the 
        threshold value written in the
         Line 2 XFP/OTX EEPROM <Condtype> 
        LINE_TX_PWR_HIGH_WNG <Probcause> 
        transmitterFailure (56) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmlineXfpWarnings 2 }



pm801rrAlmLineTxPwrLowWng OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Optical Tx Power Low Warning 
        :Warning indicating that the Line 
        2 XFP/OTX transmitter transmitter 
        output power is lower than the
         threshold value written in the 
        Line 2 XFP/OTX EEPROM <Condtype> 
        LINE_TX_PWR_LOW_WNG <Probcause> 
        transmitterFailure (56) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmlineXfpWarnings 1 }



--- *****************************************************
---     LEAF for the lineXfpAlarms2 article
--- *****************************************************
pm801rrAlmlineXfpAlarms2 OBJECT IDENTIFIER ::= { pm801rrAlmLineCrit 27 }




pm801rrAlmLineApdSupplyFault OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Rx Photodiode Power Failed 
        :This OID indicates a failure on 
        the Line 2 APD power supply <Condtype> 
        LINE_APD_SUPPLY_FAULT <Probcause> 
        receiverFailure (42) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmlineXfpAlarms2 16 }



pm801rrAlmLineTecFault OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Optical Tx Temp Regul.
         Failed :This OID indicates a failure 
        on the Line 2 TEC module <Condtype> 
        LINE_TEC_FAULT <Probcause> transmitterFailure 
        (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmlineXfpAlarms2 15 }



pm801rrAlmLineWavelengthUnlocked OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Optical Tx Wavelength Unlocked 
        :This OID indicates that the Line 
        2 wavelength error is exceeding 
        the manufacturer tolerance <Condtype> 
        LINE_WAVELENGTH_UNLOCKED <Probcause> 
        transmitterFailure (56) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmlineXfpAlarms2 14 }



pm801rrAlmLineChannelNotAcquired OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 DWDM Channel Not Acquired 
        :This OID indicates the transceiver 
        didn't tune the DWDM Channel succesfully. 
         <Help>  This status indicates
         the transceiver has not tuned
         the DWDM Channel succesfully.
         <Condtype> LINE_CHANNEL_NOT_ACQUIRED 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmlineXfpAlarms2 10 }



pm801rrAlmLineTxNr OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Optical Tx Not Ready :This 
        OID indicates a condition has arisen 
        leading to invalid data on the
         Line 2 transmitting side <Condtype> 
        LINE_TX_NR <Probcause> transmitterFailure 
        (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmlineXfpAlarms2 8 }



pm801rrAlmLineTxFault OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Optical Tx Failure :This 
        OID indicates a fault condition 
        on the Line 2 laser detected by 
        the safety syste <Condtype> LINE_TX_FAULT 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmlineXfpAlarms2 7 }



pm801rrAlmLineTxCdrNotLocked OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Optical Tx CDR Unlocked 
        :This OID indicates a loss of lock 
        on the Line 2 transmitting side 
        CDR has been detected. <Condtype> 
        LINE_TX_CDR_NOT_LOCKED <Probcause> 
        transmitterFailure (56) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmlineXfpAlarms2 6 }



pm801rrAlmLineRxNr OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Optical Rx Not Ready :This 
        OID indicates that a condition
         has arisen leading to invalid
         data on the Line 2 receiving side. 
        <Condtype> LINE_RX_NR <Probcause> 
        receiveFailure (41) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmlineXfpAlarms2 5 }



pm801rrAlmLineRxLos OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Loss Of Optical Signal
         :This bit indicates an absence 
        of signal on the XFP/OTX  <Help> 
         This alarm indicates if an optical 
        signal is detected on the line
         2 transceiver input <Condtype> 
        LINE_RX_LOS <Probcause> receiveFailure 
        (41) <Alarmtype> physicalViolation 
        (9) <Polarity> (2) 
        "
	  ::= { pm801rrAlmlineXfpAlarms2 4 }



pm801rrAlmLineRxCdrNotLocked OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Optical Rx CDR Unlocked 
        :This OID indicates that a loss 
        of lock on the Line 2 receiving 
        side CDR has been detected <Condtype> 
        LINE_RX_CDR_NOT_LOCKED <Probcause> 
        receiveFailure (41) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmlineXfpAlarms2 3 }



pm801rrAlmLineResetComplete OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Not Used :This bit indicates that 
        the internal reset process is completed 
        and the data are available <Condtype> 
        LINE_RESET_COMPLETE <Probcause> 
        other (1) <Alarmtype> other (1) 
        <Polarity> (2) 
        "
	  ::= { pm801rrAlmlineXfpAlarms2 1 }



--- *****************************************************
---     LEAF for the rrLineOtxTlhAlarms3 article
--- *****************************************************
pm801rrAlmrrLineOtxTlhAlarms3 OBJECT IDENTIFIER ::= { pm801rrAlmLineUrg 30 }




pm801rrAlmLineLaserTempHighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Laser Temp. High Alarm
         :Alarm indicating the Line 2 OTX 
        TLH laser temperature is higher 
        than the threshold written in the 
        EEPROM <Condtype> LINE_LASER_TEMP_HIGH_ALA 
        <Probcause> temperatureUnacceptable 
        (51) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmrrLineOtxTlhAlarms3 14 }



pm801rrAlmLineFreqDevHighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Freq. Deviation High Alarm 
        :Alarm indicating the Line 2 OTX 
        TLH frequency deviation is higher 
        than the threshold written in the 
        EEPROM <Condtype> LINE_FREQ_DEV_HIGH_ALA 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmrrLineOtxTlhAlarms3 12 }



pm801rrAlmLineCdrNotReady OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 CDR Not Ready :This OID 
        indicates the Clock Data Recovery 
        unit is not yet initialized   
         <Help>   This alarm indicates
         the Clock Data Recovery unit is 
        not yet initialized. <Condtype> 
        LINE_CDR_NOT_READY <Probcause>
         receiveFailure (41) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmrrLineOtxTlhAlarms3 9 }



pm801rrAlmLineAgingHighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 OTX TLH Aging High Alarm 
        :Alarm indicating the Line 2 OTX 
        TLH aging is higher than the threshold 
        written in the EEPROM <Condtype> 
        LINE_AGING_HIGH_ALA <Probcause> 
        transmitterFailure (56) <Alarmtype> 
        equipmentAlarm (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmrrLineOtxTlhAlarms3 6 }



pm801rrAlmLineModulatorAgingHighAla OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Modulator Aging High Alarm 
        :Alarm indicating the Line 2 OTX 
        TLH modulator aging is higher than 
        the threshold written in the EEPROM 
        <Condtype> LINE_MODULATOR_AGING_HIGH_ALA 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmrrLineOtxTlhAlarms3 5 }



--- *****************************************************
---     LEAF for the rrLineOtxTlhWarnings article
--- *****************************************************
pm801rrAlmrrLineOtxTlhWarnings OBJECT IDENTIFIER ::= { pm801rrAlmLineNurg 31 }




pm801rrAlmLineLaserTempHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Laser Temp. High Warning 
        :Warning indicating the Line 2
         OTX TLH laser temperature is higher 
        than the threshold written in the 
        EEPROM <Condtype> LINE_LASER_TEMP_HIGH_WARNING 
        <Probcause> temperatureUnacceptable 
        (51) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmrrLineOtxTlhWarnings 14 }



pm801rrAlmLineFreqDevHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Freq. Deviation High Warning 
        :Warning indicating the Line 2
         OTX TLH frequency deviation is 
        higher than the threshold written 
        in the EEPROM <Condtype> LINE_FREQ_DEV_HIGH_WARNING 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmrrLineOtxTlhWarnings 12 }



pm801rrAlmLineAgingHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 OTX TLH Aging High Warning 
        :Warning indicating the Line 2
         OTX TLH aging is higher than the 
        threshold written in the EEPROM 
        <Condtype> LINE_AGING_HIGH_WARNING 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmrrLineOtxTlhWarnings 6 }



pm801rrAlmLineModulatorAgingHighWarning OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Modulator Aging High Warning 
        :Warning indicating the Line 2
         OTX TLH modulator aging is higher 
        than the threshold written in the 
        EEPROM <Condtype> LINE_MODULATOR_AGING_HIGH_WARNING 
        <Probcause> transmitterFailure
         (56) <Alarmtype> equipmentAlarm 
        (5) <Polarity> (2) 
        "
	  ::= { pm801rrAlmrrLineOtxTlhWarnings 5 }








--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     CONTROLS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the synth0 article
--- *****************************************************
pm801rrCtrlsynth0 OBJECT IDENTIFIER ::= { pm801rrCtrlOther 0 }




pm801rrCtrlConfClear OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Clear Configuration Tables :This 
        bit clears the configuration tables 
        from configuration in the flash. 
         <Help>  This control restores
         the default configuration of the 
        module
        "
	  ::= { pm801rrCtrlsynth0 13 }



pm801rrCtrlConfFlash OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Write Configuration Tables :This 
        bit saves the current configuration 
        of the module as configuration
         in the flash.  <Help>  This control 
        saves the customer configuration 
        on the module
        "
	  ::= { pm801rrCtrlsynth0 9 }



pm801rrCtrlConfLoad OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Load Configuration Tables :When 
        set this enables loading from flash 
        configuration1 into the module.
        "
	  ::= { pm801rrCtrlsynth0 1 }



--- *****************************************************
---     LEAF for the synth4 article
--- *****************************************************
pm801rrCtrlsynth4 OBJECT IDENTIFIER ::= { pm801rrCtrlOther 4 }




pm801rrCtrlCorrelatOff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Disable Alarm Correlation :This 
        OID disables the alarm correlation 
        in the PM
        "
	  ::= { pm801rrCtrlsynth4 2 }



pm801rrCtrlCorrelatOn OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Enable Alarm Correlation :This 
        OID enables the alarm correlation 
        in the PM
        "
	  ::= { pm801rrCtrlsynth4 1 }



--- *****************************************************
---     LEAF for the swMgnt article
--- *****************************************************
pm801rrCtrlswMgnt OBJECT IDENTIFIER ::= { pm801rrCtrlOther 5 }




pm801rrCtrlWarmReset OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Software Warm Reset :This OID, 
        when set, causes a warm reset of 
        the Software. This reset is not 
        traffic affecting, and the configuration 
        of the Sofwtare remains unchanged. 
         <Help>  This control initiates 
        a warm reset of the module.
        "
	  ::= { pm801rrCtrlswMgnt 3 }



pm801rrCtrlColdReset OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Software Cold Reset :This OID, 
        when set, causes a cold reset of 
        the Software. This reset is traffic 
        affecting, and the configuration 
        of Software is reloaded on start-up. 
         <Help>  This control initiates 
        a cold reset of the module.
        "
	  ::= { pm801rrCtrlswMgnt 2 }



--- *****************************************************
---     LEAF for the clientXfpOnoff article
--- *****************************************************
pm801rrCtrlclientXfpOnoff OBJECT IDENTIFIER ::= { pm801rrCtrlClient 16 }




pm801rrCtrlClientXfpOnoff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        XFP/OTX Laser Shut Down :This
         OID switches off the Line 1 XFP/OTX 
         <Help>  This control defines the 
        laser state of the line 1 transceiver
        "
	  ::= { pm801rrCtrlclientXfpOnoff 1 }



--- *****************************************************
---     LEAF for the clientXfpLineLoop article
--- *****************************************************
pm801rrCtrlclientXfpLineLoop OBJECT IDENTIFIER ::= { pm801rrCtrlClient 17 }




pm801rrCtrlClientXfpLineLoop OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        XFP/OTX Loop :This OID operates 
        a loopback on the Line 1  XFP/OTX 
         <Help>  This control defines the 
        line loop back of the line 1 transceiver
        "
	  ::= { pm801rrCtrlclientXfpLineLoop 1 }



--- *****************************************************
---     LEAF for the clientXfiLoop article
--- *****************************************************
pm801rrCtrlclientXfiLoop OBJECT IDENTIFIER ::= { pm801rrCtrlClient 18 }




pm801rrCtrlClientXfiLoop OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        XFP/OTX XFI Loop :This OID operates 
        a XFI loopback on the Line 1 XFP/OTX 
          <Help>  This control defines
         the XFI loop back of the line
         transceiver
        "
	  ::= { pm801rrCtrlclientXfiLoop 1 }



--- *****************************************************
---     LEAF for the clientTunableChannel article
--- *****************************************************

pm801rrCtrlclientTunableChannel OBJECT-TYPE
	  SYNTAX Pm801rrOtxChannel
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        ITU Channel :This OID selects
         the ITU channel of the Line 1
         OTX TLH Laser  <Help>   This control 
        defines the ITU channel of the
         Line 1 OTX TLH Laser
        "
	  ::= { pm801rrCtrlClient 19 }



--- *****************************************************
---     LEAF for the clientPhotodiodeMode article
--- *****************************************************

pm801rrCtrlclientPhotodiodeMode OBJECT-TYPE
	  SYNTAX Pm801rrOtxMode
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        OTX TLH Rx Sens. Mode :This OID 
        defines the Rx sensiblity mode
         of the Line 1 OTX TLH  <Help>
           This control defines the receiver 
        sensibility mode of the Line 1
         OTX TLH Laser (OTX60, OTX80 or 
        Custom)
        "
	  ::= { pm801rrCtrlClient 20 }



--- *****************************************************
---     LEAF for the clientPhotodiodeValue article
--- *****************************************************

pm801rrCtrlclientPhotodiodeValue OBJECT-TYPE
	  SYNTAX Pm801rrAdjustValue
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        OTX TLH Rx Sensibility :This OID 
        sets the Rx sensibility of the
         Line 1 OTX TLH (custom mode only) 
         <Help>   This control defines
         the receiver sensibility value 
        (only in Custom mode) of the Line 
        1 OTX TLH Laser
        "
	  ::= { pm801rrCtrlClient 21 }



--- *****************************************************
---     LEAF for the clientPowerLaser article
--- *****************************************************

pm801rrCtrlclientPowerLaser OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Laser Output Power [3-5] :This 
        OID sets the output power value 
        on the laser of the Line 1 OTX
         TLH (AV=Power*10+158) (Unit =
         dBm)  <Help>   This control defines 
        the start-up output power of the 
        Line 1 OTX TLH
        "
	  ::= { pm801rrCtrlClient 22 }



--- *****************************************************
---     LEAF for the clientOtxVlhReset article
--- *****************************************************
pm801rrCtrlclientOtxVlhReset OBJECT IDENTIFIER ::= { pm801rrCtrlLine 23 }




pm801rrCtrlClientOtxVlhReset OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        OTX-VLH Reset :This OID resets 
        the OTX-VLH module   <Help>  This 
        control resets the OTX-TLH and
         its parameters 
        "
	  ::= { pm801rrCtrlclientOtxVlhReset 1 }



--- *****************************************************
---     LEAF for the lineXfpOnoff article
--- *****************************************************
pm801rrCtrllineXfpOnoff OBJECT IDENTIFIER ::= { pm801rrCtrlLine 24 }




pm801rrCtrlLineXfpOnoff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        XFP/OTX Laser Shut Down :This
         OID switches off the Line 2 XFP/OTX 
         <Help>  This control defines the 
        laser state of the line 2 transceiver
        "
	  ::= { pm801rrCtrllineXfpOnoff 1 }



--- *****************************************************
---     LEAF for the lineXfpLineLoop article
--- *****************************************************
pm801rrCtrllineXfpLineLoop OBJECT IDENTIFIER ::= { pm801rrCtrlLine 25 }




pm801rrCtrlLineXfpLineLoop OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        XFP/OTX Loop :This OID operates 
        a loopback on the Line 2  XFP/OTX 
         <Help>  This control defines the 
        line loop back of the line 2 transceiver
        "
	  ::= { pm801rrCtrllineXfpLineLoop 1 }



--- *****************************************************
---     LEAF for the lineXfiLoop article
--- *****************************************************
pm801rrCtrllineXfiLoop OBJECT IDENTIFIER ::= { pm801rrCtrlLine 26 }




pm801rrCtrlLineXfiLoop OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        XFP/OTX XFI Loop :This OID operates 
        a XFI loopback on the Line 2 XFP/OTX 
          <Help>  This control defines
         the XFI loop back of the line
         2 transceiver
        "
	  ::= { pm801rrCtrllineXfiLoop 1 }



--- *****************************************************
---     LEAF for the lineTunableChannel article
--- *****************************************************

pm801rrCtrllineTunableChannel OBJECT-TYPE
	  SYNTAX Pm801rrOtxChannel
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        ITU Channel :This OID selects
         the ITU channel of the Line 2
         OTX TLH Laser  <Help>   This control 
        defines the ITU channel of the
         Line 2 OTX TLH Laser
        "
	  ::= { pm801rrCtrlLine 27 }



--- *****************************************************
---     LEAF for the linePhotodiodeMode article
--- *****************************************************

pm801rrCtrllinePhotodiodeMode OBJECT-TYPE
	  SYNTAX Pm801rrOtxMode
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        OTX TLH Rx Sens. Mode :This OID 
        defines the Rx sensiblity mode
         of the Line 2 OTX TLH  <Help>
           This control defines the receiver 
        sensibility mode of the Line 2
         OTX TLH Laser (OTX60, OTX80 or 
        Custom)
        "
	  ::= { pm801rrCtrlLine 28 }



--- *****************************************************
---     LEAF for the linePhotodiodeValue article
--- *****************************************************

pm801rrCtrllinePhotodiodeValue OBJECT-TYPE
	  SYNTAX Pm801rrAdjustValue
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        OTX TLH Rx Sensibility :This OID 
        sets the Rx sensibility of the
         Line 2 OTX TLH (custom mode only) 
         <Help>   This control defines
         the receiver sensibility value 
        (only in Custom mode) of the Line 
        2 OTX TLH Laser
        "
	  ::= { pm801rrCtrlLine 29 }



--- *****************************************************
---     LEAF for the linePowerLaser article
--- *****************************************************

pm801rrCtrllinePowerLaser OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Laser Output Power [3-5] :This 
        OID sets the output power value 
        on the laser of the Line 2 OTX
         TLH (AV=Power*10+158) (Unit =
         dBm)  <Help>   This control defines 
        the start-up output power of the 
        Line 2 OTX TLH
        "
	  ::= { pm801rrCtrlLine 30 }



--- *****************************************************
---     LEAF for the lineOtxVlhReset article
--- *****************************************************
pm801rrCtrllineOtxVlhReset OBJECT IDENTIFIER ::= { pm801rrCtrlLine 31 }




pm801rrCtrlLineOtxVlhReset OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        OTX-VLH Reset :This OID resets 
        the OTX-VLH module   <Help>  This 
        control resets the OTX-TLH and
         its parameters 
        "
	  ::= { pm801rrCtrllineOtxVlhReset 1 }



--- *****************************************************
---     LEAF for the ledTest article
--- *****************************************************
pm801rrCtrlledTest OBJECT IDENTIFIER ::= { pm801rrCtrlOther 64 }




pm801rrCtrlLedOff OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Leds Off :This OID switches off 
        all the Leds as a test feature. 
         <Help>  This control initiates 
        a test leds turning all the LEDs 
        to OFF
        "
	  ::= { pm801rrCtrlledTest 3 }



pm801rrCtrlRedLed OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Red Leds Test :This OID switches 
        on all the red Leds as a test feature. 
         <Help>  This control initiates 
        a test leds turning all the LEDs 
        to red
        "
	  ::= { pm801rrCtrlledTest 2 }



pm801rrCtrlGreenLed OBJECT-TYPE
	  SYNTAX EkiOnOff
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Green Leds Test :This OID switches 
        on all the green Leds as a test 
        feature.  <Help>  This control
         initiates a test leds turning
         all the LEDs to green
        "
	  ::= { pm801rrCtrlledTest 1 }








--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     MEASURES
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the clientTemperature article
--- *****************************************************

pm801rrMesrclientTemperature OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Optical Module Temperature 
        :This OID gives the temperature 
        of the Client XFP/OTX, read from 
        the DDM (Digital Diagnostic Monitoring) 
         (Temperature = AV/256) (Unit = 
        C)  <Help>  This measure gives
         the temperature of the line 1
         transceiver
        "
	  ::= { pm801rrMesrClient 16 }



--- *****************************************************
---     LEAF for the clientTxBias article
--- *****************************************************

pm801rrMesrclientTxBias OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 XFP/OTX Tx Bias Current 
        :This OID gives the bias value
         of the Client XFP/OTX, read from 
        the DDM (Digital Diagnostic Monitoring) 
        (Bias = AV/500) (Unit = mA)  <Help> 
         This measure gives the bias of 
        the line 1 transceiver
        "
	  ::= { pm801rrMesrClient 18 }



--- *****************************************************
---     LEAF for the clientTxPower article
--- *****************************************************

pm801rrMesrclientTxPower OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Optical Module Tx Power 
        :This OID gives the transmit power 
        value of the Client XFP/OTX, read 
        from the DDM (Digital   Diagnostic 
        Monitoring)  (Power = 10*log(AV)-40) 
        (Unit = dBm)  <Help>  This measure 
        gives the Tx optical power of the 
        line 1 transceiver
        "
	  ::= { pm801rrMesrClient 19 }



--- *****************************************************
---     LEAF for the clientRxPower article
--- *****************************************************

pm801rrMesrclientRxPower OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Optical Module Rx Power 
        :This OID gives the receive power 
        value of the Client XFP/OTX, read 
        from the DDM (Digital Diagnostic 
        Monitoring) (Power = 10*log(AV)-40) 
        (Unit = dBm)  <Help>  This measure 
        gives the Rx optical power of the 
        line 1 transceiver
        "
	  ::= { pm801rrMesrClient 20 }



--- *****************************************************
---     LEAF for the lineTemperature article
--- *****************************************************

pm801rrMesrlineTemperature OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Optical Module Temperature 
        :This OID gives the temperature 
        of the Line XFP/OTX, read from
         the DDM (Digital Diagnostic Monitoring) 
         (Temperature = AV/256) (Unit = 
        C)  <Help>  This measure gives
         the temperature of the line 2
         transceiver
        "
	  ::= { pm801rrMesrLine 24 }



--- *****************************************************
---     LEAF for the lineTxBias article
--- *****************************************************

pm801rrMesrlineTxBias OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 XFP/OTX Tx Bias Current 
        :This OID gives the bias value
         of the Line XFP/OTX, read from 
        the DDM (Digital Diagnostic Monitoring) 
        (Bias = AV/500) (Unit = mA)  <Help> 
         This measure gives the bias of 
        the line 2 transceiver
        "
	  ::= { pm801rrMesrLine 26 }



--- *****************************************************
---     LEAF for the lineTxPower article
--- *****************************************************

pm801rrMesrlineTxPower OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Optical Module Tx Power 
        :This OID gives the transmit power 
        value of the Line XFP/OTX, read 
        from the DDM (Digital   Diagnostic 
        Monitoring)  (Power = 10*log(AV)-40) 
        (Unit = dBm)  <Help>  This measure 
        gives the Tx optical power of the 
        line 2 transceiver
        "
	  ::= { pm801rrMesrLine 27 }



--- *****************************************************
---     LEAF for the lineRxPower article
--- *****************************************************

pm801rrMesrlineRxPower OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Optical Module Rx Power 
        :This OID gives the receive power 
        value of the Line XFP/OTX, read 
        from the DDM (Digital Diagnostic 
        Monitoring) (Power = 10*log(AV)-40) 
        (Unit = dBm)  <Help>  This measure 
        gives the Rx optical power of the 
        line 2 transceiver
        "
	  ::= { pm801rrMesrLine 28 }



--- *****************************************************
---     LEAF for the clientAging article
--- *****************************************************

pm801rrMesrclientAging OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 OTX TLH Aging :This OID 
        gives the aging of the Line 1 OTX 
        TLH, read from the DDM (Digital 
        Diagnostic Monitoring)  (Aging
         = AV) (Unit = %)  <Help>  This 
        measure gives the aging of the
         line 1 OTX TLH
        "
	  ::= { pm801rrMesrClient 32 }



--- *****************************************************
---     LEAF for the clientLaserTemperature article
--- *****************************************************

pm801rrMesrclientLaserTemperature OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 OTX TLH Laser Temperature 
        :This OID gives the laser temperature 
        of the Line 1 OTX TLH, read from 
        the DDM (Digital Diagnostic Monitoring) 
         (Temperature = AV/256)  (Unit
         = C)  <Help>  This measure gives 
        the laser temperature of the line 
        1 OTX TLH
        "
	  ::= { pm801rrMesrClient 33 }



--- *****************************************************
---     LEAF for the clientFreqDeviation article
--- *****************************************************

pm801rrMesrclientFreqDeviation OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 OTX TLH Frequency Deviation 
        :This OID gives the frequency deviation 
        of the Line 1 OTX TLH, read from 
        the DDM (Digital Diagnostic Monitoring) 
        (Deviation = (AV-32768)*100) (Unit 
        = MHz)  <Help>   This measure gives 
        the frequency deviation of the
         line 1 OTX TLH
        "
	  ::= { pm801rrMesrClient 34 }



--- *****************************************************
---     LEAF for the clientLaserWvlength article
--- *****************************************************

pm801rrMesrclientLaserWvlength OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 1 Optical Module Wavelength 
        :This OID gives the laser wavelength 
        of the Line 1 OTX TLH, read from 
        the DDM (Digital Diagnostic Monitoring) 
        (Wavelength=299792458/((193,100+(AV-32768 
        )*12,5)*10 3))  (Unit = nm)  <Help> 
          This measure gives the laser
         wavelength of the line 1 OTX TLH
        "
	  ::= { pm801rrMesrClient 35 }



--- *****************************************************
---     LEAF for the lineAging article
--- *****************************************************

pm801rrMesrlineAging OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 OTX TLH Aging :This OID 
        gives the aging of the Line 2 OTX 
        TLH, read from the DDM (Digital 
        Diagnostic Monitoring)  (Aging
         = AV) (Unit = %)  <Help>  This 
        measure gives the aging of the
         line 2 OTX TLH
        "
	  ::= { pm801rrMesrLine 40 }



--- *****************************************************
---     LEAF for the lineLaserTemperature article
--- *****************************************************

pm801rrMesrlineLaserTemperature OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 OTX TLH Laser Temperature 
        :This OID gives the laser temperature 
        of the Line 2 OTX TLH, read from 
        the DDM (Digital Diagnostic Monitoring) 
          (Temperature = AV/256)  (Unit 
        = C)  <Help>  This measure gives 
        the laser temperature of the line 
        2 OTX TLH
        "
	  ::= { pm801rrMesrLine 41 }



--- *****************************************************
---     LEAF for the lineFreqDeviation article
--- *****************************************************

pm801rrMesrlineFreqDeviation OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 OTX TLH Frequency Deviation 
        :This OID gives the frequency deviation 
        of the Line 2 OTX TLH, read from 
        the DDM (Digital Diagnostic Monitoring) 
        (Deviation = (AV-32768)*100) (Unit 
        = MHz)  <Help>  This measure gives 
        the frequency deviation of the
         line 2 OTX TLH
        "
	  ::= { pm801rrMesrLine 42 }



--- *****************************************************
---     LEAF for the lineLaserWvlength article
--- *****************************************************

pm801rrMesrlineLaserWvlength OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65535)
	  MAX-ACCESS read-only
	  STATUS current
	  DESCRIPTION
        "
        Line 2 Optical Module Wavelength 
        :This OID gives the laser wavelength 
        of the Line 2 OTX TLH, read from 
        the DDM (Digital Diagnostic Monitoring) 
        (Wavelength=299792458/((193,100+(AV-32768 
        )*12,5)*10 3))  (Unit = nm)  <Help> 
         This measure gives the laser wavelength 
        of the line 2 OTX TLH
        "
	  ::= { pm801rrMesrLine 43 }








--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
---     CONFIG
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************



--- *****************************************************
---     LEAF for the table Group lsd
--- *****************************************************

pm801rrCfgLsd OBJECT IDENTIFIER ::= { pm801rrConfig 1 }



--- *****************************************************
---     LEAF for the table 0012
--- *****************************************************

pm801rrtableclientLsd OBJECT IDENTIFIER ::= { pm801rrCfgLsd 1 }



pm801rrCfglsdMode OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        LSD mode  on Client/Line Port
         :This OID enables/disables the 
        automatic laser shutdown on the 
        Client and Line ports
        "
	  ::= { pm801rrtableclientLsd 2 }



pm801rrCfgclientXfpAlarms OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        LSD contributors on Client port 
        :This OID configures the contributors 
        for the automatic laser shutdown 
        of the client port
        "
	  ::= { pm801rrtableclientLsd 3 }



pm801rrCfgclientXfpAbsence OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        LSD contributors on Client port 
        :This OID configures the contributors 
        for the automatic laser shutdown 
        of the client port
        "
	  ::= { pm801rrtableclientLsd 4 }



pm801rrCfglineXfpAlarms OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        LSD contributors on Line port
         :This OID configures the contributors 
        for the automatic laser shutdown 
        of the line port
        "
	  ::= { pm801rrtableclientLsd 5 }



pm801rrCfglineXfpAbsence OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        LSD contributors on Line port
         :This OID configures the contributors 
        for the automatic laser shutdown 
        of the line port
        "
	  ::= { pm801rrtableclientLsd 6 }



--- *****************************************************
---     LEAF for the table Group startUp
--- *****************************************************

pm801rrCfgStartUp OBJECT IDENTIFIER ::= { pm801rrConfig 2 }



--- *****************************************************
---     LEAF for the table 2111
--- *****************************************************

pm801rrtableclientStartup OBJECT IDENTIFIER ::= { pm801rrCfgStartUp 1 }



pm801rrCfgclientXfpCtrl OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Line 1 Port 
        :This  register configures the
         default initialisation settings 
        on the client port.
        "
	  ::= { pm801rrtableclientStartup 2 }



--- *****************************************************
---     LEAF for the table 2191
--- *****************************************************

pm801rrtablelineStartup OBJECT IDENTIFIER ::= { pm801rrCfgStartUp 2 }



pm801rrCfglineXfpCtrl OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Line 2 Port 
        :This  register configures the
         default initialisation settings 
        on the line port.
        "
	  ::= { pm801rrtablelineStartup 2 }



pm801rrCfgprotocolSelect OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Bitrate selection on Line/Client 
        port :This OID register configure 
        the bitrate for the client and
         line interface (0=9,953 Gb/s - 
        1=10,3125 Gb/s - 2=9,953 Gb/s - 
        3=10,518 Gb/s - 4=10,664 Gb/s - 
        5=10,709 Gb/s).
        "
	  ::= { pm801rrtablelineStartup 18 }



--- *****************************************************
---     LEAF for the table 2511
--- *****************************************************

pm801rrtableclientOtxtlh OBJECT IDENTIFIER ::= { pm801rrCfgStartUp 3 }



pm801rrCfgclientDitherControl OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Dither Line 
        1 :This  register configures the 
        default initialisation settings 
        on the dither of the client port.
        "
	  ::= { pm801rrtableclientOtxtlh 2 }



pm801rrCfgclientDitherRate OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Line 1 OTX TLH FM amplitude 
        :This register configures the start-up 
        width of the frequency modulation 
        of the line 1 OTX TLH
        "
	  ::= { pm801rrtableclientOtxtlh 3 }



pm801rrCfgclientDitherFhz OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Line 1 OTX TLH FM frequency 
        :This register configures the start-up 
        frequency of the frequency modulation 
        of the line 1 OTX TLH
        "
	  ::= { pm801rrtableclientOtxtlh 4 }



pm801rrCfgclientPwrLaser OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Defaut Line 1 OTX TLH output Power 
        :This register configures the start-up 
        output power of the line 1 OTX
         TLH  (Unit = dBm)
        "
	  ::= { pm801rrtableclientOtxtlh 5 }



pm801rrCfgclientFCurrent OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Line 1 OTX TLH Channel 
        :This register configures the start-up 
        laser channel of the line 1 OTX 
        TLH
        "
	  ::= { pm801rrtableclientOtxtlh 6 }



pm801rrCfgclientGridCurrent OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Line 1 OTX TLH Grid :This 
        register configures the start-up 
        laser grid of the line 1 OTX TLH
        "
	  ::= { pm801rrtableclientOtxtlh 7 }



pm801rrCfgclientF0 OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Line 1 OTX TLH lowest
         Freq :This register configures 
        the start-up lowest frequency supported 
        on the line 1 OTX TLH
        "
	  ::= { pm801rrtableclientOtxtlh 8 }



pm801rrCfgclientPhotodiodeMode OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Line 1 OTX TLH APD mode 
        :This register configures the start-up 
        APD mode of the line 1 OTX TLH
        "
	  ::= { pm801rrtableclientOtxtlh 10 }



pm801rrCfgclientPhotodiodeValue OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Line 1 OTX TLH APD atten. 
        :This register configures the start-up 
        APD attenuation on the line 1 OTX 
        TLH
        "
	  ::= { pm801rrtableclientOtxtlh 11 }



--- *****************************************************
---     LEAF for the table 2591
--- *****************************************************

pm801rrtablelineOtxtlh OBJECT IDENTIFIER ::= { pm801rrCfgStartUp 4 }



pm801rrCfglineDitherControl OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Settings on Dither Line 
        2 :This  register configures the 
        default initialisation settings 
        on the dither of the client port.
        "
	  ::= { pm801rrtablelineOtxtlh 2 }



pm801rrCfglineDitherRate OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Line 2 OTX TLH FM amplitude 
        :This register configures the start-up 
        width of the frequency modulation 
        of the line 2 OTX TLH
        "
	  ::= { pm801rrtablelineOtxtlh 3 }



pm801rrCfglineDitherFhz OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Line 2 OTX TLH FM frequency 
        :This register configures the start-up 
        frequency of the frequency modulation 
        of the line 2 OTX TLH
        "
	  ::= { pm801rrtablelineOtxtlh 4 }



pm801rrCfglinePwrLaser OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Defaut Line 2 OTX TLH output Power 
        :This register configures the start-up 
        output power of the line 2 OTX
         TLH (Unit = dBm)
        "
	  ::= { pm801rrtablelineOtxtlh 5 }



pm801rrCfglineFCurrent OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Line 2 OTX TLH Channel 
        :This register configures the start-up 
        laser channel of the line 2 OTX 
        TLH
        "
	  ::= { pm801rrtablelineOtxtlh 6 }



pm801rrCfglineGridCurrent OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Line 2 OTX TLH Grid :This 
        register configures the start-up 
        laser grid of the line 2 OTX TLH
        "
	  ::= { pm801rrtablelineOtxtlh 7 }



pm801rrCfglineF0 OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Line 2 OTX TLH lowest
         Freq :This register configures 
        the start-up lowest frequency supported 
        on the line 2 OTX TLH
        "
	  ::= { pm801rrtablelineOtxtlh 8 }



pm801rrCfglinePhotodiodeMode OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Line 2 OTX TLH APD mode 
        :This register configures the start-up 
        APD mode of the line 2 OTX TLH
        "
	  ::= { pm801rrtablelineOtxtlh 10 }



pm801rrCfglinePhotodiodeValue OBJECT-TYPE
	  SYNTAX Unsigned32 (0..65536)
	  MAX-ACCESS read-write
	  STATUS current
	  DESCRIPTION
        "
        Default Line 2 OTX TLH APD atten. 
        :This register configures the start-up 
        APD attenuation on the line 2 OTX 
        TLH
        "
	  ::= { pm801rrtablelineOtxtlh 11 }



--- *****************************************************
---     LEAF for the table Group labels
--- *****************************************************

pm801rrCfgLabels OBJECT IDENTIFIER ::= { pm801rrConfig 3 }



--- *****************************************************
---     LEAF for the table NO_VALUE
--- *****************************************************

pm801rrCfgLabelclientTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pm801rrCfgLabelclientEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pm801rrCfgLabels 1 }


pm801rrCfgLabelclientEntry OBJECT-TYPE
	SYNTAX Pm801rrCfgLabelclientEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the labels
         table
        "
	INDEX   { pm801rrCfgLabelclientIndex }
	::= { pm801rrCfgLabelclientTable 1 }


Pm801rrCfgLabelclientEntry ::=
	SEQUENCE {
	pm801rrCfgLabelclientIndex
		INTEGER,
	pm801rrCfgLabelclientPortn
		DisplayString
	}


pm801rrCfgLabelclientIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the labelclient 
        table
        "
	::= { pm801rrCfgLabelclientEntry 1 }


pm801rrCfgLabelclientPortn OBJECT-TYPE
	SYNTAX  DisplayString( SIZE(1..16))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default settings on the label
         of the Ports :These registers
         configures the default initialisation 
        settings of the labels of the ports.
        "
	::= { pm801rrCfgLabelclientEntry 3 }


--- *****************************************************
---     LEAF for the table NO_VALUE
--- *****************************************************

pm801rrCfgLabellineTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pm801rrCfgLabellineEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pm801rrCfgLabels 2 }


pm801rrCfgLabellineEntry OBJECT-TYPE
	SYNTAX Pm801rrCfgLabellineEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the labels
         table
        "
	INDEX   { pm801rrCfgLabellineIndex }
	::= { pm801rrCfgLabellineTable 1 }


Pm801rrCfgLabellineEntry ::=
	SEQUENCE {
	pm801rrCfgLabellineIndex
		INTEGER,
	pm801rrCfgLabellinePortn
		DisplayString
	}


pm801rrCfgLabellineIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the labelline 
        table
        "
	::= { pm801rrCfgLabellineEntry 1 }


pm801rrCfgLabellinePortn OBJECT-TYPE
	SYNTAX  DisplayString( SIZE(1..16))
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
        "
        Default settings on the label
         of the lines :These registers
         configures the default initialisation 
        settings of the labels of the lines.
        "
	::= { pm801rrCfgLabellineEntry 3 }


--- *****************************************************
---     LEAF for the table Group startuptablefive
--- *****************************************************

pm801rrCfgStartuptablefive OBJECT IDENTIFIER ::= { pm801rrConfig 4 }



--- *****************************************************
---     LEAF for the table 0005
--- *****************************************************

pm801rrCfgOtxtlhcapabilitiesTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Pm801rrCfgOtxtlhcapabilitiesEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        List of  Article
        "
	::= { pm801rrCfgStartuptablefive 1 }


pm801rrCfgOtxtlhcapabilitiesEntry OBJECT-TYPE
	SYNTAX Pm801rrCfgOtxtlhcapabilitiesEntry
	MAX-ACCESS not-accessible
	STATUS current
	DESCRIPTION
        "
        Row definition for the startuptablefive 
        table
        "
	INDEX   { pm801rrCfgOtxtlhcapabilitiesIndex }
	::= { pm801rrCfgOtxtlhcapabilitiesTable 1 }


Pm801rrCfgOtxtlhcapabilitiesEntry ::=
	SEQUENCE {
	pm801rrCfgOtxtlhcapabilitiesIndex
		INTEGER,
	pm801rrCfgComponentTypePortn
		Unsigned32,
	pm801rrCfgMiscellaneousPortn
		Unsigned32,
	pm801rrCfgFirstChannelPortn
		Unsigned32,
	pm801rrCfgLastChannelPortn
		Unsigned32,
	pm801rrCfgGridPortn
		Unsigned32
	}


pm801rrCfgOtxtlhcapabilitiesIndex OBJECT-TYPE
	SYNTAX  INTEGER(0..128)
	MAX-ACCESS  read-only
	STATUS current
	DESCRIPTION
        "
        Index definition for the otxtlhcapabilities 
        table
        "
	::= { pm801rrCfgOtxtlhcapabilitiesEntry 1 }


pm801rrCfgComponentTypePortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Component parameters :This OID 
        defines the component parameters
        "
	::= { pm801rrCfgOtxtlhcapabilitiesEntry 3 }


pm801rrCfgMiscellaneousPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Miscellaneous default settings 
        :This OID defines the miscellaneous 
        parameters
        "
	::= { pm801rrCfgOtxtlhcapabilitiesEntry 4 }


pm801rrCfgFirstChannelPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Number of the first channel of 
        the component :This OID defines 
        the first channel number of the 
        PM
        "
	::= { pm801rrCfgOtxtlhcapabilitiesEntry 5 }


pm801rrCfgLastChannelPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Number of the last channel of
         the component :This OID defines 
        the last channel number of the
         PM
        "
	::= { pm801rrCfgOtxtlhcapabilitiesEntry 6 }


pm801rrCfgGridPortn OBJECT-TYPE
	SYNTAX  Unsigned32 (0..65536)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
        "
        Grid value of the component :This 
        OID defines the grid of the PM
        "
	::= { pm801rrCfgOtxtlhcapabilitiesEntry 7 }



pm801rrCfgWriteConfiguration  OBJECT-TYPE
	SYNTAX EkiOnOff
	MAX-ACCESS read-write
	STATUS current
	DESCRIPTION
	"Write configuration to module:This OID 
	 writes the complete configuration to the module"
	::= { pm801rrConfig 257 }






--- *****************************************************
---     TRAP OBJECTS
--- *****************************************************

pm801rrtrapBoardNumber OBJECT-TYPE
	SYNTAX INTEGER(1..64)
	MAX-ACCESS read-only
	STATUS current
	DESCRIPTION
	"Last module which generates a trap"
	::= { pm801rrtraps 4 }







--- *****************************************************
---     GLOBAL TRAPS
--- *****************************************************

pm801rrLineTrapNotUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pm801rrAlmLineDdmWarning, pm801rrtrapBoardNumber}
	STATUS current
	--&FILTNAME    "PM801RR Line Not Urgent ON"
	--&ACTIONS     { log, minor }
	--&MATCH       { pm801rrAlmLineDdmWarning "on", pm801rrtrapBoardNumber "$2"}
	--&MESG        "DDM Warning appears on Line Port of PM801RR in Slot $2 ($A)"
	DESCRIPTION "Not urgent Line default is activated"
	::= { pm801rrtraps 30 }

pm801rrLineTrapNotUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pm801rrAlmLineDdmWarning, pm801rrtrapBoardNumber}
	STATUS current
	--&FILTNAME    "PM801RR Line Not Urgent OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      { "PM801RR Line Not Urgent ON" }
	--&MATCH       { pm801rrAlmLineDdmWarning "on", pm801rrtrapBoardNumber "$2"}
	--&MESG        "DDM Warning disappears on Line Port of PM801RR in Slot $2 ($A)"
	DESCRIPTION "Not urgent Line default disappeared"
	::= { pm801rrtraps 31 }

pm801rrLineTrapUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pm801rrAlmLineDdmAlm, pm801rrtrapBoardNumber}
	STATUS current
	--&FILTNAME    "PM801RR Line Urgent ON"
	--&ACTIONS     { log, major }
	--&MATCH       { pm801rrAlmLineDdmAlm "on", pm801rrtrapBoardNumber "$2"}
	--&MESG        "DDM Alarm appears on Line Port of PM801RR in Slot $2 ($A)"
	DESCRIPTION "Urgent Line default is activated"
	::= { pm801rrtraps 32 }

pm801rrLineTrapUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pm801rrAlmLineDdmAlm, pm801rrtrapBoardNumber}
	STATUS current
	--&FILTNAME    "PM801RR Line Urgent OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      { "PM801RR Line Urgent ON" }
	--&MATCH       { pm801rrAlmLineDdmAlm "on", pm801rrtrapBoardNumber "$2"}
	--&MESG        "DDM Alarm disappears on Line Port of PM801RR in Slot $2 ($A)"
	DESCRIPTION "Urgent Line default disappeared"
	::= { pm801rrtraps 33 }

pm801rrLineTrapCritGoesOn NOTIFICATION-TYPE
	OBJECTS {pm801rrAlmLineFail, pm801rrAlmLineHwFail, pm801rrtrapBoardNumber}
	STATUS current
	--&FILTNAME    "PM801RR Line Fail ON"
	--&ACTIONS     { log, critical }
	--&MATCH       { pm801rrAlmLineFail "on", pm801rrAlmLineHwFail "*", pm801rrtrapBoardNumber "$3"}
	--&MESG        "Line Port Down on PM801RR in Slot $3 ($A)"
	
	--&FILTNAME    "PM801RR Line HW Fail ON (Hidden)"
	--&ACTIONS     { info }
	--&MATCH       { pm801rrAlmLineFail "*", pm801rrAlmLineHwFail "on", pm801rrtrapBoardNumber "$3"}
	--&MESG        "Line Port Down on PM801RR in Slot $3 ($A)"
	DESCRIPTION "Critical Line default is activated"
	::= { pm801rrtraps 34 }

pm801rrLineTrapCritGoesOff NOTIFICATION-TYPE
	OBJECTS {pm801rrAlmLineFail, pm801rrAlmLineHwFail, pm801rrtrapBoardNumber}
	STATUS current
	--&FILTNAME    "PM801RR Line Fail OFF"
	--&ACTIONS     { log,  normal }
	--&CLEARS      { "PM801RR Line Fail ON" }
	--&MATCH       { pm801rrAlmLineFail "on", pm801rrAlmLineHwFail "*", pm801rrtrapBoardNumber "$3"}
	--&MESG        "Line Port Up on PM801RR in Slot $3 ($A)"

	--&FILTNAME    "PM801RR Line HW Fail OFF (Hidden)"
	--&ACTIONS     { info }
	--&MATCH       { pm801rrAlmLineFail "*", pm801rrAlmLineHwFail "on", pm801rrtrapBoardNumber "$3"}
	--&MESG        "Line Port Up on PM801RR in Slot $3 ($A)"
	DESCRIPTION "Critical Line default disappeared"
	::= { pm801rrtraps 35 }






--- *****************************************************
---     PORTS TRAPS
--- *****************************************************

pm801rrClientTrapNotUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pm801rrAlmClientDdmWarning, pm801rrtrapBoardNumber}
	STATUS current
	--&FILTNAME    "PM801RR Client Not Urgent ON"
	--&ACTIONS     { log, minor }
	--&MATCH       { pm801rrAlmClientDdmWarning "on", pm801rrtrapBoardNumber "$2"}
	--&MESG        "DDM Warning appears on Client Port of PM801RR in Slot $2 ($A)"
	DESCRIPTION "Not urgent client default is activated"
	::= { pm801rrtraps 40 }

pm801rrClientTrapNotUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pm801rrAlmClientDdmWarning, pm801rrtrapBoardNumber}
	STATUS current
	--&FILTNAME    "PM801RR Client Not Urgent OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      { "PM801RR Client Not Urgent ON" }
	--&MATCH       { pm801rrAlmClientDdmWarning "on", pm801rrtrapBoardNumber "$2"}
	--&MESG        "DDM Warning appears on Client Port of PM801RR in Slot $2 ($A)"
	DESCRIPTION "Not urgent client default disappeared"
	::= { pm801rrtraps 41 }

pm801rrClientTrapUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pm801rrAlmClientDdmAlm, pm801rrtrapBoardNumber}
	STATUS current
	--&FILTNAME    "PM801RR Client Urgent ON"
	--&ACTIONS     { log, major }
	--&MATCH       { pm801rrAlmClientDdmAlm "on", pm801rrtrapBoardNumber "$2"}
	--&MESG        "DDM Alarm appears on Client Port of PM801RR in Slot $2 ($A)"
	DESCRIPTION "Urgent client default is activated"
	::= { pm801rrtraps 42 }

pm801rrClientTrapUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pm801rrAlmClientDdmAlm, pm801rrtrapBoardNumber}
	STATUS current
	--&FILTNAME    "PM801RR Client Urgent OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      { "PM801RR Client Urgent ON" }
	--&MATCH       { pm801rrAlmClientDdmAlm "on", pm801rrtrapBoardNumber "$2"}
	--&MESG        "DDM Alarm disappears on Client Port of PM801RR in Slot $2 ($A)"
	DESCRIPTION "Urgent client default disappeared"
	::= { pm801rrtraps 43 }

pm801rrClientTrapCritGoesOn NOTIFICATION-TYPE
	OBJECTS {pm801rrAlmClientFail, pm801rrAlmClientHwFail, pm801rrtrapBoardNumber}
	STATUS current
	--&FILTNAME    "PM801RR Client Fail ON"
	--&ACTIONS     { log, critical }
	--&MATCH       { pm801rrAlmClientFail "on", pm801rrAlmClientHwFail "*", pm801rrtrapBoardNumber "$3"}
	--&MESG        "Client Port Down on PM801RR in Slot $3 ($A)"
	
	--&FILTNAME    "PM801RR Client HW Fail ON (Hidden)"
	--&ACTIONS     { info }
	--&MATCH       { pm801rrAlmClientFail "*", pm801rrAlmClientHwFail "on", pm801rrtrapBoardNumber "$3"}
	--&MESG        "Client Port Down on PM801RR in Slot $3 ($A)"
	DESCRIPTION "Critical client default is activated"
	::= { pm801rrtraps 44 }

pm801rrClientTrapCritGoesOff NOTIFICATION-TYPE
	OBJECTS {pm801rrAlmClientFail, pm801rrAlmClientHwFail, pm801rrtrapBoardNumber}
	STATUS current
	--&FILTNAME    "PM801RR Client Fail OFF"
	--&ACTIONS     { log, normal }
	--&CLEARS      { "PM801RR Client Fail ON" }
	--&MATCH       { pm801rrAlmClientFail "on", pm801rrAlmClientHwFail "*", pm801rrtrapBoardNumber "$3"}
	--&MESG        "Client Port Up on PM801RR in Slot $3 ($A)"
	
	--&FILTNAME    "PM801RR Client HW Fail OFF (Hidden)"
	--&ACTIONS     { info }
	--&MATCH       { pm801rrAlmClientFail "*", pm801rrAlmClientHwFail "on", pm801rrtrapBoardNumber "$3"}
	--&MESG        "Client Port Up on PM801RR in Slot $3 ($A)"
	DESCRIPTION "Critical client default disappeared"
	::= { pm801rrtraps 45 }






--- *****************************************************
---     HW TRAPS
--- *****************************************************

pm801rrPowerTrapUrgentGoesOn NOTIFICATION-TYPE
	OBJECTS {pm801rrAlmDefFuseB, pm801rrAlmDefFuseA , pm801rrtrapBoardNumber}
	STATUS current
	--&FILTNAME    "PM801RR Fuse A Fail ON"
	--&ACTIONS     { log, major }
	--&MATCH       { pm801rrAlmDefFuseB "*", pm801rrAlmDefFuseA "on", pm801rrtrapBoardNumber "$3"}
	--&MESG        "Power Input A Fail on PM801RR in Slot $3 ($A)"

	--&FILTNAME    "PM801RR Fuse B Fail ON"
	--&ACTIONS     { log, major }
	--&MATCH       { pm801rrAlmDefFuseB "on", pm801rrAlmDefFuseA "*", pm801rrtrapBoardNumber "$3"}
	--&MESG        "Power Input B Fail on PM801RR in Slot $3 ($A)"
	DESCRIPTION "Urgent power supply default is activated"
	::= { pm801rrtraps 50 }
pm801rrPowerTrapUrgentGoesOff NOTIFICATION-TYPE
	OBJECTS {pm801rrAlmDefFuseB, pm801rrAlmDefFuseA , pm801rrtrapBoardNumber}
	STATUS current
	--&FILTNAME    "PM801RR Fuse A&B Fail OFF"
	--&ACTIONS     { log, normal}
	--&CLEARS      { "PM801RR Fuse A Fail ON", "PM801RR Fuse B Fail ON" }
	--&MATCH       { pm801rrAlmDefFuseB "on", pm801rrAlmDefFuseA "on", pm801rrtrapBoardNumber "$3"}
	--&MESG        "Power Inputs A and B Present on PM801RR in Slot $3 ($A)"
	DESCRIPTION "Urgent power supply default disappeared"
	::= { pm801rrtraps 51 }






END