Dell-LAN-TRAP-MIB DEFINITIONS ::= BEGIN

-- Broadcom FastPath Radius Authentication Client MIB
-- Copyright 2016 Broadcom.
-- This SNMP Management Information Specification
-- embodies Broadcom's confidential and proprietary
-- intellectual property.  Broadcom retains all title
-- and ownership in the Specification including any revisions.

-- This Specification is supplied "AS IS", Broadcom 
-- makes no warranty, either expressed or implied,
-- as to the use, operation, condition, or performance of the
-- Specification.

IMPORTS
    OBJECT-TYPE, NOTIFICATION-TYPE
        FROM SNMPv2-SMI 
    DisplayString, DateAndTime
	FROM SNMPv2-TC
    dellLan, dellLanCommon
        FROM Dell-Vendor-MIB;

-- Dell EMC alarms specific global parameters are defined in this group.
dellAlarmGroup MODULE-IDENTITY
        LAST-UPDATED "200504260000Z" -- 26 Apr 2005 12:00:00 GMT
        ORGANIZATION "Dell EMC"
        CONTACT-INFO ""
        DESCRIPTION
          " "

    ::= { dellLanCommon 1 }

-- dellAlarmGroup OBJECT IDENTIFIER ::= { dellLanCommon 1  }

----------------------------------------------
-- Variable binding list parameters for traps:
----------------------------------------------

dellTrapInfo OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
       "This text string may be used to provide additional information
        regarding the trap being sent.  Any specific formatting information
        is given in the trap definition."
    ::= { dellAlarmGroup 1 }

dellTrapSeverity OBJECT-TYPE
    SYNTAX INTEGER  {
         clear(0),
         info(1),
         minor(2),
         major(3),
         critical(4)
    }
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
      "The severity type of the enterprise-specific trap sent to the
      Network Management Station by the Dell managed device.  The
      Severity level are defined as follows:
      Critical - service affecting event.
      Major    - a major error which is not service affecting but does
                 require immediate user attention to prevent further
                 degredation of the system, which may lead to a critical
                 error.  For example, if a redundant port failure would
                 be considered a major event whereas the failure of an
                 unprotected port is a critical event.
      Minor    - a minor event which is not service affecting and is
                 unlikely to lead to a major or critical event.  The user
                 does not need to take immediate actions but some action
                 is required to clear the event.
      Info     - a notification to the user of some event that does not
                 require any user action.  For example, a security 
                 notification is useful information but does not require
                 the user to take any specific immediate action.  This
                 event is not cleared.
      Clear    - this special trap is sent to clear some previously sent
                 trap.  Note that if the sequence number sent with the
                 clear event is 0 then the clear event is used to indicate
                 that all outstanding event of this particular type on a
                 given source (dellTrapSource) has been cleared.  If the
                 event sequence number (dellTrapSeqNum) is sent with a 
                 non-zero value, then the clear event is sent to clear only
                 the specific trap instance designated by the sequence
                 number in question."
    ::= { dellAlarmGroup 2 }

dellTrapSource OBJECT-TYPE
    SYNTAX DisplayString
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
    "The trap source is a string identifying the component of the device 
     generating the trap.  The source identifies the component associated 
     with the fault.  This may for example, identify the unit, slot, port, 
     and possibly logical ports (VLAN, LAG) from which the fault occurs.  
     The format of the source string is: 'TYPE=#:TYPE=#:...' where the
     TYPE may be one of 'unit' or 'slot' or 'port' or 'VLAN' or 'LAG'.
     For example: 
     'unit=3:slot=1:port=2' - indicates the trap comes from port 2 in slot 1
                              of the switch #3 in the stack.
     'unit=2:VLAN=10'       - indicates the trap comes from VLAN=10 in unit 2.
     'unit=1'               - indicates the trap comes from unit 1."
::= { dellAlarmGroup 3 }

dellTrapSeqNum OBJECT-TYPE
     SYNTAX Unsigned32
     MAX-ACCESS read-only
     STATUS current
     DESCRIPTION
     "Since SNMP traps are transported using UDP, there is a possibility 
      for the trap to be lost in transit.  To allow the NMS the ability 
      to detect this possibility, all traps will include a trap sequence 
      number as part of its variable binding list.  The trap sequence number 
      may be reset each time the system reboots and will increment for each 
      trap sent from the device.  When a missing trap sequence number is 
      detected the NMS may be able to refresh its state of the switch to 
      determine what event it may have missed."
::= { dellAlarmGroup 4 }

dellTrapTimeStamp OBJECT-TYPE
     SYNTAX DateAndTime
     MAX-ACCESS read-only
     STATUS current
     DESCRIPTION
     "The trap header includes the system up time which mark when the trap 
      was generated, but often it is important to know the absolute time 
      when the trap was generated.  This time stamp is based on GMT 
      (universal time) time zone.  This will allow the timestamps to be 
      correlated consistently across a large network."
::= { dellAlarmGroup 5 }

---------------------------------------------------------------------------
-- Trap definitions:
-- All traps must have at least the following VAR-BIND:
-- dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity,
-- dellTrapInfo.
--
-- The trap may include additional variables which may be defined in the
-- object list following these objects for proprietary traps.
--
-- For standard traps, this rule does not apply.
--------------------------------------------------------------------------- 

hwResourceOverflow NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum, 
                  dellTrapSource, dellTrapSeverity, 
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Indicates that a switch hardware resource overflowed.  The
         dellTrapSource should indicate the unit number whereas dellTrapInfo
         should identify the resource that overflowed."
    ::= { dellLan 500 }

swResourceOverflow NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum, 
                  dellTrapSource, dellTrapSeverity, 
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Indicates that a switch software resource overflowed.  The
         dellTrapSource should indicate the unit number whereas dellTrapInfo
         should identify the resource that overflowed (e.g. maximum 
         VLAN/LAG/MACs/IPs exceeded)."
    ::= { dellLan 510 }

configChanged NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Indicates that the switch configuration has changed.  The 
         dellTrapSource should indicate the source of the change such
         as the unit, slot, port, VLAN, LAG, etc.  The dellTrapInfo
         may indicate additional information regarding the change."
    ::= { dellLan 520 }

-- This trap may be implementation dependent. If it does not apply to a
-- particular implementation then it may be safely ignored.
resetRequired NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum, 
                  dellTrapSource, dellTrapSeverity, 
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "This trap indicates that in order to perform the last SET request, 
         a reset operation of the router/bridge is required. This may occur 
         for any number of reasons such as if the change affects the routing
         protocols to be switched from SPF to STP.  This trap warns the user
         to manually reset the switch using either physical or software reset." 
    ::= { dellLan 530 }

endTftp NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum, 
                  dellTrapSource, dellTrapSeverity, 
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "This trap indicates that the device finished a TFTP
         transaction with the management station. The dellTrapInfo field
         will provide TFTP exit code and name/type of the file being
         transferred." 
    ::= { dellLan 540 }

abortTftp NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum, 
                  dellTrapSource, dellTrapSeverity, 
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
       "This trap indicates that in the device aborted a TFTP session with
        the management station. The dellTrapInfo field will provide TFTP 
        exit code and name/type of the file being transferred."
    ::= { dellLan 550 }

startTftp NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum, 
                  dellTrapSource, dellTrapSeverity, 
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Informational trap indicating that the device has intiated a
         TFTP session. dellTrapInfo will contain the name/type of the file 
         being transferred."
    ::= { dellLan 560 }

linkFailure NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum, 
                  dellTrapSource, dellTrapSeverity, 
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Link failure detected, no backup available. The dellTrapSource
         should indicate the fail link."
    ::= { dellLan 570 }

linkFailureSwitchBackUp NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum, 
                  dellTrapSource, dellTrapSeverity, 
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Automantic switchover to backup link because of main link fault.
         The dellTrapSource indicates the backup link coming on, and the
         dellTrapInfo indicates the failed link."
    ::= { dellLan 580 }

mainLinkUp NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum, 
                  dellTrapSource, dellTrapSeverity, 
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Communication returned to main link. The dellTrapSource indicates
         the main link coming up, and the dellTrapInfo indicates the backup
         link."
    ::= { dellLan 590 }

errorsDuringInit  NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum, 
                  dellTrapSource, dellTrapSeverity, 
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "This trap indicates that the an error occured during initialization
         phase of the switch.  Additional information is provided in the
         dellTrapInfo field." 
    ::= { dellLan 600 }

vlanDynPortAdded  NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum, 
                  dellTrapSource, dellTrapSeverity, 
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
         "Indicates that a port was dynamically added to the VLAN.  The
          dellTrapSource will indicate the VLAN, and the dellTrapInfo will
          indicate the port being added."
    ::= { dellLan 610 }

vlanDynPortRemoved  NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum, 
                  dellTrapSource, dellTrapSeverity, 
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
         "Indicates that a port was dynamically removed from a VLAN.  The
          dellTrapSource will indicate the VLAN, and the dellTrapInfo will
          indicate the port being removed."
    ::= { dellLan 620 }

-- === Begin Zero-Hop Edge Routing ===
-- The following traps are related to routing.  These traps may be software 
-- implementation dependent.  If these are not appropriate they may be
-- ignored.
ipZhrReqStaticConnNotAccepted NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum, 
                  dellTrapSource, dellTrapSeverity, 
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
         "The requested static connection was not accepted because there is
          no available IP virtual address to allocate to it."
    ::= { dellLan 630 }

ipZhrVirtualIpAsSource NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum, 
                  dellTrapSource, dellTrapSeverity, 
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
         "The virtual IP address appeared as a source IP. All the connections 
          using it will be deleted and it will not be further allocated to 
          new connections."
    ::= { dellLan 640 }

ipZhrNotAllocVirtualIp NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum, 
                  dellTrapSource, dellTrapSeverity, 
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
         "The source IP address sent an ARP specifying a virtual IP which 
          was not allocated for this source.  This virtual IP will not be 
          allocated to connections of this specific source IP."
    ::= { dellLan 650 }
-- === End Zero-Hop Edge Routing ===

-- === Start Stacking specific Traps ===
-- The following traps are related to stacking.  If the switch does not
-- support stacking, these may safely be ignored.
--
-- Note that these traps define a set of conditions based upon a particular
-- operational paradigm of stacking.  If these traps do not quite match
-- a given implementation then new traps may be defined for the feature in the
-- vendor specific section of the mibs.

stackMasterFailed NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum, 
                  dellTrapSource, dellTrapSeverity, 
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Indicates that the stack master unit has failed.  This trap is
         generated by the new master when it takes over the stack.  The
         dellTrapSource should be the new master unit #, and the
         dellTrapInfo should identify the old master unit #." 
    ::= { dellLan  660 }

stackNewMasterElected NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Indicates when a new master has been elected.  This is different
         from a stack failure in that the master has not failed but for
         some reason a new master has been elected (e.g. the user requested
         a new master.  The trap should be generated by the new master.
         the dellTrapSource should identify the new master, and the
         dellTrapInfo should identify the old master."
    ::= { dellLan  670 }

stackMemberUnitFailed NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Indicates that a member of the stack has failed.  This condition
         is detected by the master unit so the dellTrapSource should indicate
         the master unit ID and the dellTrapInfo should indicate the
         member unit that failed." 
    ::= { dellLan  680 }

stackNewMemberUnitAdded NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Indicates that a new member unit has been added to the stack.
         This trap is generated by the master unit so the dellTrapSource
         should indicate the master unit ID, and the dellTrapInfo should
         identify the new unit ID." 
    ::= { dellLan  690 }

stackMemberUnitRemoved NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Indicates that a member unit has been removed from the stack.
         The dellTrapSource indicates the master unit ID and the
         dellTrapInfo indicates the unit ID being removed."
    ::= { dellLan  700 }

stackSplitMasterReport NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Indicates that the stack has split into two distinct stacks which
         means that each stack may end up with its own master temporarily
         until the stack is rejoined.  This is possibly different from the 
         stackMemberUnitFailed trap, which indicates only a single unit
         failure.  This trap indicates that the master has lost track of
         part of the stack membership so that the other units may elect 
         their own master.  The dellTrapSource should indicate the master
         unit ID and the dellTrapInfo should identify the units that are
         split from the main stack."
    ::= { dellLan  710 }

stackSplitNewMasterReport NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Indicates that the stack has split into two distinct stacks which
         means that each stack may end up with its own master temporarily
         until the stack is rejoined. This trap is generated by the new
         master unit elected in the split sub-stack.  The dellTrapSource
         should identify the new master unit ID, and the dellTrapInfo should
         identify the old master unit ID before the split occured."  
    ::= { dellLan  720 }

stackRejoined NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Indicates that previously split stack has rejoined. The rejoined
         stack will elect a master and this trap should be generated by the
         elected master.  The dellTrapSource should indicate the master unit
         ID and the dellTrapInfo should list the unit IDs of the members."
    ::= { dellLan  730 }

stackLinkFailed NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Indicates a failure in one of the stacking link.  If this stack
         was connected in a ring, then the failure of a stacking link
         results in a chain stack instead of a ring.  Another failure
         in the chain topology would result in a split stack.  If the
         stack is connected in a meshed or star topology then multiple
         link failure may be tolerated.  This trap may be generated by
         any unit within the stack and must indicate the source of the
         failure.  The dellTrapSource should identify one end of the link
         where the failure is detected.  The dellTrapInfo may provide
         additional information about the failure." 
    ::= { dellLan  740 }

-- === End Stacking specific Traps ===

dhcpAllocationFailure NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "DHCP failed to allocate an IP address to a requesting host
         because of memory shortage or inadequate configuration of
         available IP addresses."
    ::= { dellLan  750 }

dot1dStpPortStateForwarding NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "The trap is sent by a bridge when any of its configured ports
         transitions from the Learning state to the Forwarding state."
    ::= { dellLan  760 }

dot1dStpPortStateNotForwarding NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "The trap is sent by a bridge when any of its configured ports
         transitions from the Forwarding state to the Blocking state."
    ::= { dellLan  770 }

policyDropPacketTrap NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Indicates that the packet drop due to the policy.  This trap
         may result in a huge number of trap packets and should be used
         only for debugging purposes.  The number of traps sent per
         time period is user configurable and the user may enable/disable 
         generation of this trap."
    ::= { dellLan  780 }

policyForwardPacketTrap NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Indicates that the packet has forward based on policy. The number 
         of traps sent per time period is user configurable and the user 
         may enable/disable generation of this trap."
    ::= { dellLan  790 }

igmpV1MsgReceived NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "An IGMP Message of v1 received on a given interface. The
         dellTrapSource should indicate the interface."
    ::= { dellLan  800 }

vrrpEntriesDeleted NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "One or more VRRP entries deleted due to IP interface deletion or 
         transition. "
    ::= { dellLan  810 }

trunkPortAddedTrap NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Informational trap indicating that a port is added to a trunk.  
         The dellTrapSource should indicate the trunk to which the port
         is added.  The dellTrapInfo should indicate the port being added."
    ::= { dellLan  820 }

trunkPortRemovedTrap NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "This warning is generated when a port removed from a trunk.
         The dellTrapSource should indicate the trunk from which the port
         is removed.  The dellTrapInfo should indicate the port being
         removed."
    ::= { dellLan  830 }

-- trunkPortNotCapableTrap is a duplicate OID as above. we may end up on no using the following trap. So commenting for time being
--trunkPortNotCapableTrap NOTIFICATION-TYPE
--    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
--                 dellTrapSource, dellTrapSeverity,
--                  dellTrapInfo }
--    STATUS   current
--
--    DESCRIPTION
--        "Informational trap indicating that a port can not be added to
--         a trunk because of device limitations or different swIfType.
--         The dellTrapSource should identify the trunk whereas the
--         dellTrapInfo should indicate the port being added and any additional
--         information."
--    ::= { dellLan  830 }

lockPortTrap NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Informational trap indicating that a port that is blocked from 
         MAC learning has receive a frame with new source Mac Address.
         The dellTrapSource should identify the port and the dellTrapInfo
         should specify the new MAC address received."
    ::= { dellLan  840 }

vlanDynVlanAdded  NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
         "Indicates that a dynamic VLAN has been added via GVRP.  The
          dellTrapSource should identify the VLAN being added."
    ::= { dellLan  850 }

vlanDynVlanRemoved  NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
         "Indicates that a dynamic VLAN has been removed via GVRP.  The
          dellTrapSource should identify the VLAN being removed."
    ::= { dellLan  860 }

vlanDynamicToStatic  NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
         "Indicates that a dynamic VLAN has been made static.  The 
          dellTrapSource should identify the VLAN."
    ::= { dellLan  870 }

vlanStaticToDynamic  NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
         "Indicates that a static VLAN has been made dynamic.  The
          dellTrapSource should identify the VLAN."
    ::= { dellLan  880 }

envMonFanStateChange NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Trap indicating the fan state.  The dellTrapSource should identify
         the exact fan index if there are multiple fans.  The dellTrapInfo
         may provide additional info relating to the fan new state."
    ::= { dellLan  890 }

envMonPowerSupplyStateChange NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Trap indicating the power supply state.  The dellTrapSource should
         identify the exact power supply.  The dellTrapInfo may provide
         additional info regarding the power state."
    ::= { dellLan  900 }

envMonTemperatureRisingAlarm NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Trap indicating that the temperature in the device has exceeded the
         device specific safe temperature threshold."
    ::= { dellLan  910 }

copyFinished NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Informational trap indicating that the device has finished
         a copy operation successfully."
    ::= { dellLan  920 }

copyFailed NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Informational trap indicating that the copy operation has failed."
    ::= { dellLan  930 }

dot1xPortStatusAuthorizedTrap NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Informational trap indicating that port 802.1x status is authorized."
    ::= { dellLan  940 }

dot1xPortStatusUnauthorizedTrap NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Warning trap is indicating that port 802.1x status is unAuthorized."
    ::= { dellLan  950 }

broadcastStormDetected NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Indicates that a broadcast storm has been detected.  The 
         dellTrapSource should indicate the port on which the broadcast
         storm is detected."
    ::= { dellLan  960 }

stpElectedAsRoot NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Indicates that the switch has been elected as the new STP root."
    ::= { dellLan  970 }

stpNewRootElected NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Indicates that a new root has been elected.  The dellTrapSource
         should indicate the member unit number and the dellTrapInfo should
         provide information on the new root."
    ::= { dellLan  980 }

igmpElectedAsQuerier NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Indicates that this switch has been elected as the new IGMP
         snooping querier."
    ::= { dellLan  990 }

invalidUserLoginAttempted NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Indicates that an invalid user tries to login to the CLI or Web.
         The dellTrapSource should indicate the unit member ID and the
         dellTrapInfo should indicate whether the login attempt is on the
         CLI or Web and the IP address from which the attempt was made." 
    ::= { dellLan  1000 }

managementACLViolation NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Indicates that an SNMP request or CLI/Web access request was
         received but does not meet the management ACL rules.  For example,
         if the request comes from an invalid IP address or has the wrong 
         SNMP community string (for V1/2c) or is not authenticated for
         SNMPv3, etc.  The dellTrapSource should indicate the unit # and
         the dellTrapInfo should indicate which interface (web, cli, snmp)
         is violated and the source IP address of the request." 
    ::= { dellLan  1010 }

sfpInserted NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Indicates that an SFP was inserted into the system.
         The dellTrapSource should indicate the unit # and
         the dellTrapInfo should indicate on which interface 
         was the SFP inserted." 
    ::= { dellLan  1020 }


sfpRemoved NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Indicates that an SFP was removed from the system.
         The dellTrapSource should indicate the unit # and
         the dellTrapInfo should indicate from which interface 
         was the SFP removed." 
    ::= { dellLan  1030 }


xfpInserted NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Indicates that an XFP was inserted into the system.
         The dellTrapSource should indicate the unit # and
         the dellTrapInfo should indicate on which interface 
         was the XFP inserted." 
    ::= { dellLan  1040 }


xfpRemoved NOTIFICATION-TYPE
    OBJECTS   { dellTrapTimeStamp, dellTrapSeqNum,
                  dellTrapSource, dellTrapSeverity,
                  dellTrapInfo }
    STATUS   current

    DESCRIPTION
        "Indicates that an XFP was removed from the system.
         The dellTrapSource should indicate the unit # and
         the dellTrapInfo should indicate from which interface 
         was the XFP removed." 
    ::= { dellLan  1050 }

END