DMOS-HW-MONITOR-MIB DEFINITIONS ::= BEGIN
IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, Integer32
        FROM SNMPv2-SMI
    TEXTUAL-CONVENTION, TruthValue, DisplayString
        FROM SNMPv2-TC
    datacomDevicesMIBs
        FROM DATACOM-SMI
    UnsignedPercent
        FROM DMOS-TC-MIB;

dmosHwMonitorMIB MODULE-IDENTITY
    LAST-UPDATED "201701020000Z"
    ORGANIZATION "DATACOM"
    CONTACT-INFO
                "DATACOM

                 Postal: DATACOM
                     Rua America, 1000
                     Eldorado do Sul, RS
                     CEP 92990-000
                             BRAZIL

                 Tel:+55(51)3933 3000
                 Fax:+55(51)3933 3003

                 E-mail: datacom@datacom.ind.br"
    DESCRIPTION "This module contains DmOS thermal information and status monitoring objects."
    REVISION "201701020000Z"
    DESCRIPTION "First revision"
    ::= { datacomDevicesMIBs 6 }

EnvironmentSensorTemperature ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "d-1"
    STATUS      current
    DESCRIPTION ""
    SYNTAX Integer32

EnvironmentSensorStatus ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION ""
    SYNTAX      INTEGER {fail(-2),error(-1),normal(0),high(1),low(2),critical(3)}

environment OBJECT IDENTIFIER ::= { dmosHwMonitorMIB 1 }

environmentChassisTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF EnvironmentChassisEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "List of chassis for which thermal management information is available"
    ::= { environment 1 }

environmentChassisEntry OBJECT-TYPE
    SYNTAX      EnvironmentChassisEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "Chassis identification field"
    INDEX { environmentChassisId }
        ::= { environmentChassisTable 1 }

EnvironmentChassisEntry ::=
    SEQUENCE {
        environmentChassisId Unsigned32
    }

environmentChassisId OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Chassis identifier"
    ::= { environmentChassisEntry 1 }

environmentSlotTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF EnvironmentSlotEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "List of slots for which thermal management information is available"
    ::= { environment 2 }

environmentSlotEntry OBJECT-TYPE
    SYNTAX      EnvironmentSlotEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "Slot thermal information structure"
    INDEX { environmentChassisId, environmentSlotId }
        ::= { environmentSlotTable 1 }

EnvironmentSlotEntry ::=
    SEQUENCE {
        environmentSlotId DisplayString
    }

environmentSlotId OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Slot identifier"
    ::= { environmentSlotEntry 1 }

temperatureSensorTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF TemperatureSensorEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "List of temperature sensors present on a given slot and chassis"
    ::= { environment 3 }

temperatureSensorEntry OBJECT-TYPE
    SYNTAX      TemperatureSensorEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "Temperature sensor information structure"
    INDEX { environmentChassisId, environmentSlotId, temperatureSensorId }
        ::= { temperatureSensorTable 1 }

TemperatureSensorEntry ::=
    SEQUENCE {
        temperatureSensorId DisplayString,
        temperatureSensorDescription DisplayString,
        temperatureSensorMaxTemperature EnvironmentSensorTemperature,
        temperatureSensorMinTemperature EnvironmentSensorTemperature,
        temperatureSensorHysteresis EnvironmentSensorTemperature,
        temperatureSensorCurrentTemperature EnvironmentSensorTemperature,
        temperatureSensorTemperatureReadError TruthValue,
        temperatureSensorTemperatureStatus EnvironmentSensorStatus
    }

temperatureSensorId OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "Temperature sensor identifier"
    ::= { temperatureSensorEntry 1 }

temperatureSensorDescription OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Temperature sensor description"
    ::= { temperatureSensorEntry 2 }

temperatureSensorMaxTemperature OBJECT-TYPE
    SYNTAX      EnvironmentSensorTemperature
    UNITS       "C"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "High temperature alarm threshold"
    ::= { temperatureSensorEntry 3 }

temperatureSensorMinTemperature OBJECT-TYPE
    SYNTAX      EnvironmentSensorTemperature
    UNITS       "C"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Low temperature alarm threshold"
    ::= { temperatureSensorEntry 4 }

temperatureSensorHysteresis OBJECT-TYPE
    SYNTAX      EnvironmentSensorTemperature
    UNITS       "C"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Hysteresis value for both high and low temperature alarms"
    ::= { temperatureSensorEntry 5 }

temperatureSensorCurrentTemperature OBJECT-TYPE
    SYNTAX      EnvironmentSensorTemperature
    UNITS       "C"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Current temperature value being read by the sensor"
    ::= { temperatureSensorEntry 6 }

temperatureSensorTemperatureReadError OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Indicates if an error occured while trying to read from the sensor"
    ::= { temperatureSensorEntry 7 }

temperatureSensorTemperatureStatus OBJECT-TYPE
    SYNTAX      EnvironmentSensorStatus
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Temperature status based on minimum and maximum thresholds"
    ::= { temperatureSensorEntry 8 }

fanTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF FanEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "List of individual fans manageable on a given fan module/slot"
    ::= { environment 4 }

fanEntry OBJECT-TYPE
    SYNTAX      FanEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "Fan information structure"
    INDEX { environmentChassisId, environmentSlotId, fanId }
        ::= { fanTable 1 }

FanEntry ::=
    SEQUENCE {
        fanId DisplayString,
        fanDescription DisplayString,
        fanControl UnsignedPercent,
        fanSpeed Unsigned32,
        fanSpeedReadError TruthValue,
        fanSpeedStatus EnvironmentSensorStatus
    }

fanId OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "Fan identifier"
    ::= { fanEntry 1 }

fanDescription OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Fan description"
    ::= { fanEntry 2 }

fanControl OBJECT-TYPE
    SYNTAX      UnsignedPercent
    UNITS       "%"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Percentage of maximum fan speed applied for thermal control"
    ::= { fanEntry 3 }

fanSpeed OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "RPM"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Current speed of the fan"
    ::= { fanEntry 4 }

fanSpeedReadError OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Indicates if an error occured while trying to read from the sensor"
    ::= { fanEntry 5 }

fanSpeedStatus OBJECT-TYPE
    SYNTAX      EnvironmentSensorStatus
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Indicates the current state of the fan based on its speed"
    ::= { fanEntry 6 }

END