-- MIB NAME : System Log Common mib
-- FILE NAME: SSL.mib
-- DATE     : 2009/02/17
-- VERSION  : 2.02
-- PURPOSE  : To construct the MIB structure of System Log management
--            for proprietary enterprise
-- -----------------------------------------------------------------------------
-- MODIFICTION HISTORY:
-- -----------------------------------------------------------------------------
-- Version, Date, Author
-- Description:
--  [New Object]
--  [Modification]
-- Notes: (Requested by who and which project)
--
-- Version 2.02, 2009/02/17, Susan Lu
-- [New Object]
-- [1]Add "swSysLogServerAddrType" and "swSysLogServerAddr" to support IPv6 
--    syslog server.   
-- [Modification]
-- [1]Obsolete "swSysLogServerIPAddress".
--    For support IPv6 syslog server.
-- Notes: Requested by Susan Lu for DES3200
--
-- Version 2.01, 2009/01/15, Green zhu
-- [Modification]
-- [1]Add value list "emergency(4)", "alert(5)", "critical(6)", "error(7)",
--    "notice(8)" and "debug(9)" in swSysLogServerSeverity.
--    For support 8 severity levels.
--
-- Version 2.00, 2007/03/27, Yedda
-- This is the first formal version for universal MIB definition.
-- ----------------------------------------------------------------------------- 

SYSLOG-MIB DEFINITIONS ::= BEGIN

    IMPORTS
        MODULE-IDENTITY,OBJECT-TYPE,IpAddress
                                        FROM SNMPv2-SMI
        InetAddress, InetAddressType  FROM INET-ADDRESS-MIB
        RowStatus           		FROM SNMPv2-TC
    	dlink-common-mgmt  	        FROM DLINK-ID-REC-MIB;


    swSysLogMIB MODULE-IDENTITY
	    LAST-UPDATED "0902170000Z"
	    ORGANIZATION "D-Link Corp."
	    CONTACT-INFO
	        "http://support.dlink.com"
	    DESCRIPTION
		    "The Structure of System Log Information for the
		     proprietary enterprise."
        ::= { dlink-common-mgmt 12 }

    swSysLogCtrlState OBJECT-TYPE
        SYNTAX  INTEGER {
               other(1),
               disabled(2),
               enabled(3)
               }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
            "This object enables or disables the System Log function
            during system runtime."
        ::= { swSysLogMIB 1 }
 
-- -----------------------------------------------------------------------------
-- swSysLogServerTable
-- -----------------------------------------------------------------------------
    swSysLogServerTable OBJECT-TYPE
        SYNTAX  SEQUENCE OF SwSysLogServerEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
            "This table contains System Log Server information."
        ::= { swSysLogMIB 2 }

    swSysLogServerEntry OBJECT-TYPE
        SYNTAX  SwSysLogServerEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION
            "A list of information about the System Log Server."
        INDEX  { swSysLogServerIndex }
        ::= { swSysLogServerTable 1 }

    SwSysLogServerEntry ::=
        SEQUENCE {
            swSysLogServerIndex
                INTEGER,
            swSysLogServerIPAddress
                IpAddress,
            swSysLogServerFacility
                INTEGER,
             swSysLogServerSeverity
                INTEGER,
            swSysLogServerUDPPort
                INTEGER,
            swSysLogServerState
                INTEGER,
            swSysLogServerRowStatus
                RowStatus,  
            swSysLogServerAddrType   
          	InetAddressType,
	    swSysLogServerAddr       
		InetAddress  
        }

    swSysLogServerIndex OBJECT-TYPE
        SYNTAX  INTEGER (1..4)
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
            "The index entry of the unique System Log Server entry."
        ::= { swSysLogServerEntry 1 }

    swSysLogServerIPAddress OBJECT-TYPE
        SYNTAX  IpAddress
        MAX-ACCESS  read-create
        STATUS  obsolete
        DESCRIPTION
            "specifies the IP address of the System Log Server."
        ::= { swSysLogServerEntry 2 }

    -- The Facilities and Severities of the messages are numerically coded with decimal
    -- values.  Some of the operating system daemons and processes have been assigned
    -- Facility values.  Process and daemons that have not been explicitly assigned a
    -- Facility may use any of the "local use" facilities or they may use the "use-level"
    -- Facility.  Those Facilities that have been designated are shown in Table 1 and
    -- Severity level indicators are described in Table 2 of RFC3614 along with  their
    -- numerical code values.
    --    However, in this mib, only Numerical Code 16 ~ 23; Facilities(local0 ~ local7)
    -- are implemented in Facilities. Severity levels included are informational, warning
    -- and critical.

    swSysLogServerFacility OBJECT-TYPE
		SYNTAX  INTEGER {
               local0(0),
               local1(1),
               local2(2),
               local3(3),
               local4(4),
               local5(5),
               local6(6),
               local7(7)
               }
        MAX-ACCESS  read-create
        STATUS  current
        DESCRIPTION
            "syslog Message Facilities"
        ::= { swSysLogServerEntry 3 }

    swSysLogServerSeverity OBJECT-TYPE
        SYNTAX  INTEGER {
               all(1),
               warning(2),
               informational(3),
               emergency(4),
               alert(5),
               critical(6),
               error(7),
               notice(8),
               debug(9)
               }
        MAX-ACCESS  read-create
        STATUS  current
        DESCRIPTION
            "syslog Message Severities"
        ::= { swSysLogServerEntry 4 }

    swSysLogServerUDPPort OBJECT-TYPE
        SYNTAX  INTEGER
        MAX-ACCESS  read-create
        STATUS  current
        DESCRIPTION
            "syslog uses the user datagram protocol (UDP) as its underlying transport
             layer mechanism. The UDP port that has been assigned to syslog is 514. It
             is RECOMMENDED that the source port also be 514 to indicate that the message
             is from the syslog process of the sender, but there have been cases seen
             where valid syslog messages have come from a sender with a source port other
             than 514. If the sender uses a source port other than 514 then it is
             RECOMMENDED that subsequent messages
             will always be  from  the single consistent port used by the sender."
        DEFVAL  { 514 }
        ::= { swSysLogServerEntry 5 }

    swSysLogServerState OBJECT-TYPE
        SYNTAX  INTEGER {
               other(1),
               disabled(2),
               enabled(3)
               }
        MAX-ACCESS  read-create
        STATUS  current
        DESCRIPTION
            "Enables or disables the specified System Log Server during runtime."
        ::= { swSysLogServerEntry 6 }

    swSysLogServerRowStatus OBJECT-TYPE
        SYNTAX  RowStatus
        MAX-ACCESS  read-create
        STATUS  current
        DESCRIPTION
            "Indicates the status of this entry. When creating a syslog server
             entry, the IP address should also be set."
        ::= { swSysLogServerEntry 7 }  
         
    swSysLogServerAddrType OBJECT-TYPE
        SYNTAX        InetAddressType
        MAX-ACCESS    read-create
        STATUS        current
        DESCRIPTION
            "Specifies the address type of the System Log Server."
        ::= { swSysLogServerEntry 8 }
  
    swSysLogServerAddr	OBJECT-TYPE
    	SYNTAX	InetAddress
    	MAX-ACCESS   read-create
    	STATUS	current
    	DESCRIPTION
               "Specifies the address of the System Log Server."   
       ::= { swSysLogServerEntry 9 }  
        


-- -----------------------------------------------------------------------------
-- swLogSaveCtrl
-- -----------------------------------------------------------------------------
    swLogSaveCtrl			OBJECT IDENTIFIER ::= { swSysLogMIB 3 }

    swLogSaveMethod OBJECT-TYPE
        SYNTAX  INTEGER {
        	   time-interval(1),
        	   on-demand(2),
       		   log-trigger(3)
               }
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
            "This configuration is used to set the method used to save logs."
        ::= { swLogSaveCtrl 1 }

    swLogSaveTimeInterval OBJECT-TYPE
        SYNTAX  INTEGER (1..65535)
        MAX-ACCESS  read-write
        STATUS  current
        DESCRIPTION
            "Save log to flash every xxx minutes if the time interval method is implemented
            (if no log entries occur during this period, don't save)."
        ::= { swLogSaveCtrl 2 }

-- -----------------------------------------------------------------------------
  swSysLogCtrl	OBJECT IDENTIFIER ::= { swSysLogMIB 4 }

  swSysLogCtrlClearLog OBJECT-TYPE
        SYNTAX  INTEGER{
        	other(1),
        	start(2)
        	}
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Clear the switch history log."
        ::= { swSysLogCtrl 1 }

  swSysLogCtrlClearDangerousCtrl OBJECT IDENTIFIER ::= { swSysLogCtrl 2 }

  swSysLogCtrlClearDangerousUnitID OBJECT-TYPE
        SYNTAX      INTEGER
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Used to clear dangerous logs on a specific unit. The default
             value of this object is the ID of the master unit. That is,
             the master ID will be read before making any changes. The last
             value written to the object will be kept and then be supplied
             for successive GET/GET-NEXT requests."
        ::= { swSysLogCtrlClearDangerousCtrl 1 }

  swSysLogCtrlClearDangerousLog OBJECT-TYPE
        SYNTAX  INTEGER{
        	other(1),
        	start(2)
        	}
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Clear the dangerous switch logs."
        ::= { swSysLogCtrlClearDangerousCtrl 2 }

END