-- L A N O P T I C S - H U B - M I B . m y
-- 
-- March 1996, Keith Horil
--
-- Copyright (c) 1996 by cisco Systems, Inc.
-- All rights reserved.
-- *****************************************************************
--
-- This mib was developed by LanOptics


LANOPTICS-HUB-MIB DEFINITIONS ::= BEGIN

-- MIB II Extension Definitions for hub management

IMPORTS 
         OBJECT-TYPE
       	        FROM RFC-1212
         enterprises
	      	FROM RFC1155-SMI
         DisplayString
                FROM RFC1213-MIB;

    BITMAP ::= INTEGER  
      -- bitwise info represented by a single integer

    lanOptics    OBJECT IDENTIFIER ::= { enterprises 224 }
    lanOpticsHub    OBJECT IDENTIFIER ::= { lanOptics 1 }

snMaxSlots    OBJECT-TYPE
    SYNTAX     INTEGER (1..16)
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
    "The limit on the total number of slots that the
     Hub chassis has."
    ::=  { lanOpticsHub 1 }

snSlotsNum   OBJECT-TYPE
    SYNTAX            INTEGER
    ACCESS            read-only
    STATUS            mandatory
    DESCRIPTION
    "The actual number of slots occupied by the Hub modules ."
    ::=  { lanOpticsHub 2 }

snConfig   OBJECT-TYPE
    SYNTAX            DisplayString
    ACCESS            read-only
    STATUS            mandatory
    DESCRIPTION
    "A list of all modules occupying slots in Hub
    in accordance with snSlotsNum."
    ::=  { lanOpticsHub 3 }

snLLActiveNMS  OBJECT-TYPE
    SYNTAX            INTEGER {
        -- inactive (0),
        active (1)
        }
    ACCESS            read-write
    STATUS            mandatory
    DESCRIPTION
    "States whether the NMS-431X is active (1) or 
      inactive (0). For internal use only. 
      Should not be modified."
     ::=   { lanOpticsHub 4 }

snReset   OBJECT-TYPE
    SYNTAX            INTEGER
    ACCESS            read-write
    STATUS            mandatory
    DESCRIPTION
    "Resets the management module of the Hub."
    ::=  { lanOpticsHub 5 }

snInternalID  OBJECT-TYPE
    SYNTAX            DisplayString
    ACCESS            read-only
    STATUS            mandatory
    DESCRIPTION
    "The internal address of the management module (NMS-431X)."
    ::=   { lanOpticsHub 6 }

snDirtyBit   OBJECT-TYPE
    SYNTAX            BITMAP
    ACCESS            read-only
    STATUS            mandatory
    DESCRIPTION
    "Low level description in bits for changes made 
     in the  system."
    ::=  { lanOpticsHub 7 }

snSlotsTable   OBJECT-TYPE
    SYNTAX                SEQUENCE OF SnSlotsEntry
    ACCESS                not-accessible
    STATUS                mandatory
    DESCRIPTION
    "A list of slots entries.  The number of entries 
     is  given by the value of snSlotsNum."
    ::=  { lanOpticsHub 8 }

snSlotsEntry  OBJECT-TYPE
    SYNTAX                SnSlotsEntry
    ACCESS                not-accessible
    STATUS                mandatory
    DESCRIPTION
    "A slot entry containing a high and low 
     level description of the module in the slot."
    INDEX                 { INTEGER }
    ::=   { snSlotsTable 1 }

SnSlotsEntry ::= SEQUENCE {
        snCardName
        DisplayString,
        snCardDescr
        DisplayString,
        snLLHwRevision
        INTEGER,
        snLLSwRevision
        INTEGER,
        snLLControl0
        BITMAP,
        snLLControl1
        BITMAP,
        snPollInf       
        OCTET STRING,
        snResetSlot
        INTEGER,
	snPollInfCode
	OCTET STRING,
	snAssCode
	OCTET STRING
    }

snCardName   OBJECT-TYPE
    SYNTAX                DisplayString
    ACCESS                read-write
    STATUS                mandatory
    DESCRIPTION
    "Description of the card (module) name and type
     (IOM,LBM,BKM,NMS). It is set by Management entity .
     If not set by the Management entity - will response with HW,SW Rev."
    ::=   { snSlotsEntry 1 }

snCardDescr   OBJECT-TYPE
    SYNTAX                DisplayString
    ACCESS                read-write
    STATUS                mandatory
    DESCRIPTION
    "Description of the card media, connectors and
     hardware.- not accesible in Low Level. In High Level will be set
     by the Management entity (for agents above v5.0)"
        ::=   { snSlotsEntry 2 }

snLLHwRevision  OBJECT-TYPE
    SYNTAX                INTEGER
    ACCESS                read-only
    STATUS                mandatory
    DESCRIPTION
    "Low level description of the module's hardware 
     revision (module type). For internal use only!"
    ::=   { snSlotsEntry 9 }

snLLSwRevision  OBJECT-TYPE
    SYNTAX                INTEGER
    ACCESS                read-only
    STATUS                mandatory
    DESCRIPTION
    "Low level description of the module's software 
     revision (module revision). For internal use only!"
    ::=    { snSlotsEntry 10 }

snLLControl0  OBJECT-TYPE
    SYNTAX                BITMAP
    ACCESS                read-write
    STATUS                mandatory
    DESCRIPTION
    "Low level description of control actions on the 
     module. Bit per port. For internal use only!"
    ::=    { snSlotsEntry 14 }

snLLControl1 OBJECT-TYPE
    SYNTAX                BITMAP
    ACCESS                read-write
    STATUS                mandatory
    DESCRIPTION
    "Low level description of control actions on the 
    module. Bit per port. For internal use only!."
    ::=  { snSlotsEntry 15 }

snPollInf        OBJECT-TYPE
    SYNTAX   OCTET STRING
    ACCESS   read-only
    STATUS   mandatory
    DESCRIPTION
    "Low level status description of this module
    represented by an internal structure. For internal use only."
    ::=  { snSlotsEntry 29 }

snResetSlot        OBJECT-TYPE
    SYNTAX   INTEGER
    ACCESS   read-write
    STATUS   mandatory
    DESCRIPTION
     "Reset this slot (e.g. LBM module, NMS module). If this slot
      is the one the Agent occupies, reset the agent (same effect
      as snReset variable).
      If this is a special slot (0xF), reset the device mapped 
      to this slot (e.g. the router )."
    ::=  { snSlotsEntry 38 }

snPollInfCode        OBJECT-TYPE
    SYNTAX   OCTET STRING
    ACCESS   read-write
    STATUS   mandatory
    DESCRIPTION
     "This variable is set with assembly code for pollInf structure (per slot)"
    ::=  { snSlotsEntry 41 }

snAssCode        OBJECT-TYPE
    SYNTAX   OCTET STRING
    ACCESS   read-write
    STATUS   mandatory
    DESCRIPTION
     "This variable is set with assembly code that should be perform immediatly (per slot)"
    ::=  { snSlotsEntry 42 }

snPairAddress     OBJECT-TYPE
    SYNTAX            INTEGER
    ACCESS            read-write
    STATUS            mandatory
    DESCRIPTION
    "Low level port address."
    ::=  { lanOpticsHub 9 }

snPairData           OBJECT-TYPE
    SYNTAX            INTEGER
    ACCESS            read-write
    STATUS            mandatory
    DESCRIPTION
    "Low level port data. The value of this variable is read/written
     from/to the I/O address in snPairAddress variable."
    ::=  { lanOpticsHub 10 }

-- Hub related alerts data

snHubSplitTable   OBJECT-TYPE
   SYNTAX                SEQUENCE OF SnHubSplitEntry
   ACCESS                not-accessible
   STATUS                mandatory
   DESCRIPTION
      "Status of each split card."
   ::=  { lanOpticsHub 11 }

snHubSplitEntry  OBJECT-TYPE
    SYNTAX                SnHubSplitEntry
    ACCESS                not-accessible
    STATUS                mandatory
    INDEX                 { INTEGER }
    ::=   { snHubSplitTable 1 }

SnHubSplitEntry ::= SEQUENCE {
       snHubSplitStatus
                 INTEGER    
    }

snHubSplitStatus    OBJECT-TYPE
    SYNTAX      INTEGER {
           -- normal (0),
            splitted (1),
            missing (2)
    }
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
           "This variable describes the status of this split module."
    ::=  { snHubSplitEntry 1 }

snHubPSTable   OBJECT-TYPE
    SYNTAX                SEQUENCE OF SnHubPSEntry
    ACCESS                not-accessible
    STATUS                mandatory
    DESCRIPTION
    "Status of each Power supply."
   ::=  { lanOpticsHub 12 }

snHubPSEntry  OBJECT-TYPE
     SYNTAX                SnHubPSEntry
     ACCESS                not-accessible
     STATUS                mandatory
     INDEX                 { INTEGER }
     ::=   { snHubPSTable 1 }

SnHubPSEntry ::= SEQUENCE {
    snHubPSStatus
                 INTEGER    
    }


snHubPSStatus    OBJECT-TYPE
    SYNTAX      INTEGER {
       --      normal (0),
             malfunctioning (1),
             missing (2)
    }
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
               "This variable describes the status of this Power Supply."
    ::=  { snHubPSEntry 1 }


snHubFanTable   OBJECT-TYPE
    SYNTAX                SEQUENCE OF SnHubFanEntry
    ACCESS                not-accessible
    STATUS                mandatory
    DESCRIPTION
    "Status of each Fan."
   ::=  { lanOpticsHub 13 }

snHubFanEntry  OBJECT-TYPE
    SYNTAX                SnHubFanEntry
    ACCESS                not-accessible
    STATUS                mandatory
    INDEX                 { INTEGER }
    ::=   { snHubFanTable 1 }

SnHubFanEntry ::= SEQUENCE {
      snHubFanStatus
                 INTEGER    
    }

snHubFanStatus    OBJECT-TYPE
    SYNTAX      INTEGER {
     --      normal (0),
             malfunctioning (1),
             missing (2)
    }
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
               "This variable describes the status of this Fan."
    ::=  { snHubFanEntry 1 }

snHubSlotsTable   OBJECT-TYPE
    SYNTAX                SEQUENCE OF SnHubSlotsEntry
    ACCESS                not-accessible
    STATUS                mandatory
    DESCRIPTION
    "Hub's alerts related information per slot"
   ::=  { lanOpticsHub 14 }

snHubSlotsEntry  OBJECT-TYPE
    SYNTAX                SnHubSlotsEntry
    ACCESS                not-accessible
    STATUS                mandatory
    INDEX                 { INTEGER }
    ::=   { snHubSlotsTable 1 }

SnHubSlotsEntry ::= SEQUENCE {
             snHubSlotConnected
                 INTEGER,
             snHubSlotFreqError
                 INTEGER,
             snHubSlotRevChanged
                 INTEGER
    }

snHubSlotConnected    OBJECT-TYPE
    SYNTAX      INTEGER {
       --   connected (0),
            disconnected (1)
    }
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
               "This variable signifies that this entire slot
                was disconnected or reconnected by a management entity."
    ::=  { snHubSlotsEntry 1 }

snHubSlotFreqError    OBJECT-TYPE
    SYNTAX      INTEGER {
          --    no-error (0),
                slot-4M (4),
                slot-16M (16)
    }
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
               "This variable signifies that this slot frequency
                differs from the back-plane's."
    ::=  { snHubSlotsEntry 2 }

snHubSlotRevChanged    OBJECT-TYPE
    SYNTAX      INTEGER {
          --    changed (0),
                unchanged (1)
    }
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION 
    "This variable signifies that this slot SW revision
     has changed."
    ::=  { snHubSlotsEntry 3 }

   snCompanionHW OBJECT-TYPE
   	     SYNTAX  INTEGER
   	     ACCESS  read-only
   	     STATUS  mandatory
   	     DESCRIPTION
   		"Gives the value of the Hardware and software revision
               that is sharing the (PC) bus with the agent, e.g, 
                a Cisco Router PC-Card. If no hardware exists, the value
                should be 0xFF."
   	     ::= { lanOpticsHub 15 }


   snCompanionReset OBJECT-TYPE
   	     SYNTAX  INTEGER
   	     ACCESS  read-write
   	     STATUS  mandatory
   	     DESCRIPTION
   		"Send Reset to the companion hardware(cisco router)"
   	     ::= { lanOpticsHub 16 }


   snCompanionStatus OBJECT-TYPE
   	     SYNTAX  BITMAP
   	     ACCESS  read-only
   	     STATUS  mandatory
   	     DESCRIPTION
   		"Gives the companion status.
               For cisco router: Bit0 - Lan Active led(1-on,0-off)
                                 Bit2 - ISDN present bit
                                 Bit3 - O.k. Led(1-on,0-off)"
   	     ::= { lanOpticsHub 17 }

snGenPortsTable   OBJECT-TYPE
    SYNTAX                SEQUENCE OF SnGenPortsEntry
    ACCESS                not-accessible
    STATUS                mandatory
    DESCRIPTION
    "A table of all possible I/O ports in address range is 0xC000 - 0xFFFF" 
    ::=  { lanOpticsHub 18 }

snGenPortsEntry  OBJECT-TYPE
    SYNTAX                SnGenPortsEntry
    ACCESS                not-accessible
    STATUS                mandatory
    DESCRIPTION
    "An I/O port entry. Each byte of the I/O address is represented
     by one index digit; e.g, instance 255.12 is I/O address (port) 0xFF0C."
    INDEX                 { INTEGER, INTEGER }
    ::=   { snGenPortsTable 1 }

SnGenPortsEntry ::= SEQUENCE {
        snPortValue
        BITMAP
    }

snPortValue   OBJECT-TYPE
    SYNTAX                BITMAP
    ACCESS                read-write
    STATUS                mandatory
    DESCRIPTION
    "The I/O port value."
    ::=   { snGenPortsEntry 1 }

END