-- CISCO-LWAPP-DOT11-CLIENT-CALIB-MIB.my
-- Dot11 Wireless Clients Calibration MIB
--   
-- December 2005, Devesh Pujari, Prasanna Viswakumar
--   
-- Copyright (c) 2005-2006, 2011 by Cisco Systems Inc.
-- All rights reserved.
-- *******************************************************************

CISCO-LWAPP-DOT11-CLIENT-CALIB-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY,
    OBJECT-TYPE,
    Unsigned32,
    Integer32
        FROM SNMPv2-SMI
    MODULE-COMPLIANCE,
    OBJECT-GROUP
        FROM SNMPv2-CONF
    TimeStamp,
    MacAddress,
    TimeInterval,
    TruthValue,
    RowStatus,
    StorageType
        FROM SNMPv2-TC
    cLApSysMacAddress,
    cLApDot11IfSlotId
        FROM CISCO-LWAPP-AP-MIB
    ciscoMgmt
        FROM CISCO-SMI;


-- ********************************************************************
-- *  MODULE IDENTITY
-- ********************************************************************

ciscoLwappDot11ClientCalibMIB MODULE-IDENTITY
    LAST-UPDATED    "201904090000Z"
    ORGANIZATION    "Cisco Systems Inc."
    CONTACT-INFO
            "Cisco Systems,
            Customer Service
            Postal: 170 West Tasman Drive
            San Jose, CA  95134
            USA
            Tel: +1 800 553-NETS

            Email: cs-wnbu-snmp@cisco.com"
    DESCRIPTION
        "This MIB is intended to be implemented on all those
        devices operating as Central controllers, that
        terminate the Light Weight Access Point Protocol
        tunnel from Cisco Light-weight LWAPP Access Points.

        Information provided by this MIB is about the
        configuration and monitoring of 802.11 wireless
        clients in the network.

        The relationship between CC and the LWAPP APs
        can be depicted as follows:

        +......+     +......+     +......+           +......+
        +      +     +      +     +      +           +      +
        +  CC  +     +  CC  +     +  CC  +           +  CC  +
        +      +     +      +     +      +           +      +
        +......+     +......+     +......+           +......+
        ..            .             .                 .
        ..            .             .                 .
        .  .            .             .                 .
        .    .            .             .                 .
        .      .            .             .                 .
        .        .            .             .                 .
        +......+ +......+     +......+      +......+          +......+
        +      + +      +     +      +      +      +          +      +
        +  AP  + +  AP  +     +  AP  +      +  AP  +          +  AP  +
        +      + +      +     +      +      +      +          +      +
        +......+ +......+     +......+      +......+          +......+
        .              .             .                 .
        .  .              .             .                 .
        .    .              .             .                 .
        .      .              .             .                 .
        .        .              .             .                 .
        +......+ +......+     +......+      +......+          +......+
        +      + +      +     +      +      +      +          +      +
        +  MN  + +  MN  +     +  MN  +      +  MN  +          +  MN  +
        +      + +      +     +      +      +      +          +      +
        +......+ +......+     +......+      +......+          +......+

        The LWAPP tunnel exists between the controller and
        the APs.  The MNs communicate with the APs through
        the protocol defined by the 802.11 standard.

        LWAPP APs, upon bootup, discover and join one of the
        controllers and the controller pushes the configuration,
        that includes the WLAN parameters, to the LWAPP APs.
        The APs then encapsulate all the 802.11 frames from
        wireless clients inside LWAPP frames and forward
        the LWAPP frames to the controller.

                           GLOSSARY

        Access Point ( AP )
        -------------------

        An entity that contains an 802.11 medium access
        control ( MAC ) and physical layer ( PHY ) interface
        and provides access to the distribution services via
        the wireless medium for associated clients.  

        LWAPP APs encapsulate all the 802.11 frames in
        LWAPP frames and sends them to the controller to which
        it is logically connected.

        Light Weight Access Point Protocol ( LWAPP ) 
        --------------------------------------------

        This is a generic protocol that defines the 
        communication between the Access Points and the
        Central Controller.

        Mobile Node ( MN )
        ------------------

        A roaming 802.11 wireless device in a wireless
        network associated with an access point. Mobile Node,
        Mobile Station(Ms) and client are used 
        interchangeably. 

        Signal to Noise Ratio ( SNR )
        -----------------------------

        It is a measure used in science and engineering 
        that compares the level of a desired signal to 
        the level of background noise. It is defined as 
        the ratio of signal power to the noise power. 
        A ratio higher than 1:1 indicates more signal than 
        noise. While SNR is commonly quoted for electrical 
        signals, it can be applied to any form of signal.

        Received Signal Strength Indicator ( RSSI )
        -------------------------------------------

        It is a measurement of the power present in a 
        received radio signal. 

        Radio Frequency Identification ( RFID )
        -------------------------------------------

        It is a technology that uses radio waves to transfer data 
        from an electronic tag, called RFID tag or label, attached 
        to an object, through a reader for the purpose of identifying 
        and tracking the object. 

        REFERENCE

        [1] Wireless LAN Medium Access Control ( MAC ) and
        Physical Layer ( PHY ) Specifications 

        [2] Draft-obara-capwap-lwapp-00.txt, IETF Light 
        Weight Access Point Protocol"
    REVISION        "201904090000Z"
    DESCRIPTION
        "Added Following scalar objects
        - cLD11RfidRssiExpiryTime
        - cLD11RfidRssiHalflifeTime
        - cLD11RfidNotifyThresholdTime
        - cLD11RfidDataEnable
        - cLD11RfidTimeout"        
    REVISION        "201111250000Z"
    DESCRIPTION
        "Added following OBJECT-GROUP:
        - cLD11ClientCalibClientConfigGroup
        - cLD11ClientCalibGlobalConfigGroup
        - cLD11ClientCalibRssiDataSampleGroup
        Depreated following OBJECT-GROUP:
        - ciscoLwappDot11ClientCalibMIBConfigGroup
        Added new compliance:
        - ciscoLwappDot11ClientCalibMIBComplianceRev1"
    REVISION        "200702120000Z"
    DESCRIPTION
        "Added ciscoLwappDot11ClientCalibMIBConfigGroupSup1
        OBJECT-GROUP."
    REVISION        "200604110000Z"
    DESCRIPTION
        "Initial version of this MIB module."
    ::= { ciscoMgmt 522 }


ciscoLwappDot11ClientCalibMIBNotifs  OBJECT IDENTIFIER
    ::= { ciscoLwappDot11ClientCalibMIB 0 }

ciscoLwappDot11ClientCalibMIBObjects  OBJECT IDENTIFIER
    ::= { ciscoLwappDot11ClientCalibMIB 1 }

ciscoLwappDot11ClientCalibMIBConform  OBJECT IDENTIFIER
    ::= { ciscoLwappDot11ClientCalibMIB 2 }

cldccConfig  OBJECT IDENTIFIER
    ::= { ciscoLwappDot11ClientCalibMIBObjects 1 }

cldccStatus  OBJECT IDENTIFIER
    ::= { ciscoLwappDot11ClientCalibMIBObjects 2 }

cldccRssiSamples  OBJECT IDENTIFIER
    ::= { cldccStatus 1 }

-- ********************************************************************
-- Wireless Client Calibration
-- ********************************************************************

cLD11ClientCalibTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CLD11ClientCalibEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This table represents the calibration for the
        802.11 wireless clients that would associate
        to the APs that have joined this controller.

        An entry is created through an explicit management
        action initiated by the administrator through a
        network management station by specifying the
        calibration parameters for a particular client
        identified by cLD11ClientCalibMacAddress and setting
        the RowStatus object to 'createAndGo'.  An existing
        entry is deleted by setting the RowStatus object to 
        'destroy'.  The object cLD11ClientCalibTableMaxEntries
        represents the maximum number of entries in this
        table."
    ::= { cldccConfig 1 }

cLD11ClientCalibEntry OBJECT-TYPE
    SYNTAX          CLD11ClientCalibEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "Each entry represents a conceptual row in this
        table and provides the information about the
        calibration parameters for wireless clients."
    INDEX           { cLD11ClientCalibMacAddress } 
    ::= { cLD11ClientCalibTable 1 }

CLD11ClientCalibEntry ::= SEQUENCE {
        cLD11ClientCalibMacAddress        MacAddress,
        cLD11ClientCalibBeaconInterval    TimeInterval,
        cLD11ClientCalibRowStatus         RowStatus,
        cLD11ClientCalibNumberOfRadios    Unsigned32,
        cLD11ClientCalibNumberOfSamples   Unsigned32,
        cLD11ClientCalibSamplesCollected  Unsigned32,
        cLD11ClientCalibBeaconIntervalExt TimeInterval,
        cLD11ClientCalibStorageType       StorageType
}

cLD11ClientCalibMacAddress OBJECT-TYPE
    SYNTAX          MacAddress
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This object specifies the MAC address of the
        802.11 wireless client for which the 
        calibration parameters in this entry are 
        applicable and uniquely identifies this entry." 
    ::= { cLD11ClientCalibEntry 1 }

cLD11ClientCalibBeaconInterval OBJECT-TYPE
    SYNTAX          TimeInterval (400..3240000)
    UNITS           "hundredths-seconds"
    MAX-ACCESS      read-create
    STATUS          deprecated
    DESCRIPTION
        "This object specifies the time interval, expressed
        here in hundredths of a second at which an AP
        issues radio measurement request messages to a
        client for every SSID.  It is not recommended to
        configure values less than 10 seconds (1000).
        The value configured through this object is
        reflected in the operation of the LWAPP APs only if
        cLD11ClientCalibBeaconEnabled is set to 'true'.

        This object has been deprecated and is replaced by the
        object cLD11ClientCalibBeaconIntervalExt."
    DEFVAL          { 60000 } 
    ::= { cLD11ClientCalibEntry 2 }

cLD11ClientCalibRowStatus OBJECT-TYPE
    SYNTAX          RowStatus
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "The object that represents the status of a
        specific instance of a row in this table.
        Initially set to a value of 'createAndGo' by
        the User when a row is created, the status
        as represented by this object is automatically
        set to 'active' if and when the row creation
        is successful.  To delete the specific instance
        of a row, User should set this object to
        'destroy'. To create an entry in this table, it is
        mandatory to specify the cLD11ClientCalibMacAddress,
        cLD11ClientCalibNumberOfRadios (number of radios 
        to be used in the calibration) and 
        cLD11ClientCalibNumberOfSamples (no. of calibration
        samples to be collected per radio)." 
    ::= { cLD11ClientCalibEntry 3 }

cLD11ClientCalibNumberOfRadios OBJECT-TYPE
    SYNTAX          Unsigned32
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "This object specifies the number of radios
        used in this calibration." 
    ::= { cLD11ClientCalibEntry 4 }

cLD11ClientCalibNumberOfSamples OBJECT-TYPE
    SYNTAX          Unsigned32
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "This object specifies the number of RSSI samples for
        a given radio, used in this calibration." 
    ::= { cLD11ClientCalibEntry 5 }

cLD11ClientCalibSamplesCollected OBJECT-TYPE
    SYNTAX          Unsigned32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates the number of
        samples available for this client." 
    ::= { cLD11ClientCalibEntry 6 }

cLD11ClientCalibBeaconIntervalExt OBJECT-TYPE
    SYNTAX          TimeInterval
    UNITS           "hundredths-seconds"
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "This object specifies the time interval, expressed
        here in hundredths of a second at which an AP
        issues radio measurement request messages to a
        client for every SSID.  It is not recommended to
        configure values less than 10 seconds (1000).
        The value configured through this object is
        reflected in the operation of the LWAPP APs only if
        cLD11ClientCalibBeaconEnabled is set to 'true'."
    DEFVAL          { 60000 } 
    ::= { cLD11ClientCalibEntry 7 }

cLD11ClientCalibStorageType OBJECT-TYPE
    SYNTAX          StorageType
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "This object specifies the storage type of this
        conceptual row."
    DEFVAL          { volatile } 
    ::= { cLD11ClientCalibEntry 8 }
 


cLD11ClientCalibTableMaxEntries OBJECT-TYPE
    SYNTAX          Unsigned32 (1..25)
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the maximum number of entries allowed
        in cLD11ClientCalibTable." 
    ::= { cldccConfig 2 }
-- ********************************************************************
-- *  Client Calibration RSSI Data table
-- ********************************************************************

cLD11ClientCalibDataTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CLD11ClientCalibDataEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This table contains the RSSI data samples
        collected for 802.11 client based on the 
        information provided in the cldccLD11ClientCalibTable.
        Entries are automatically added by the controller
        as and when samples are available.
        This data is used by the NMS for location
        calibration of the 8022.11 clients."
    ::= { cldccRssiSamples 1 }

cLD11ClientCalibDataEntry OBJECT-TYPE
    SYNTAX          CLD11ClientCalibDataEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "Each entry represents a conceptual row in this
        table and provides the information about the
        samples for location calibration of a 802.11 
        client."
    INDEX           {
                        cLD11ClientCalibMacAddress,
                        cLApSysMacAddress,
                        cLApDot11IfSlotId,
                        clD11ClientCalibDataTimeStamp,
                        clD11ClientCalibDataAntennaIndex
                    } 
    ::= { cLD11ClientCalibDataTable 1 }

CLD11ClientCalibDataEntry ::= SEQUENCE {
        clD11ClientCalibDataTimeStamp     TimeStamp,
        clD11ClientCalibDataAntennaIndex  INTEGER,
        clD11ClientCalibDataRssiValue     Integer32,
        clD11ClientCalibDataTransmitPower Integer32
}

clD11ClientCalibDataTimeStamp OBJECT-TYPE
    SYNTAX          TimeStamp
    UNITS           "milliseconds"
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This object indicates the time this sample was
        collected. This is the absolute system time that 
        this sample was collected." 
    ::= { cLD11ClientCalibDataEntry 1 }

clD11ClientCalibDataAntennaIndex OBJECT-TYPE
    SYNTAX          INTEGER  {
                        antenna1(1),
                        antenna2(2)
                    }
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This object indicates the antenna which
        received the probe request from client." 
    ::= { cLD11ClientCalibDataEntry 2 }

clD11ClientCalibDataRssiValue OBJECT-TYPE
    SYNTAX          Integer32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates the RSSI value for this
        sample." 
    ::= { cLD11ClientCalibDataEntry 3 }

clD11ClientCalibDataTransmitPower OBJECT-TYPE
    SYNTAX          Integer32
    UNITS           "dbm"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates the transmit power level for
        a calibrating client." 
    ::= { cLD11ClientCalibDataEntry 4 }
 


-- ********************************************************************
-- *  Location scalars
-- ********************************************************************

cLD11ClientCalibRssiAlgorithm OBJECT-TYPE
    SYNTAX          INTEGER  {
                        unknown(1),
                        simple(2),
                        average(3)
                    }
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the algorithm used
        to average RSSI and SNR values. 
          unknown(1)  - the algorithm used is unknown
          simple(2)   - simple is used for the calculation
          average(3)  - average RSSI is used as algorithm" 
    ::= { cldccConfig 3 }

cLD11ClientCalibRssiClientExpiryTimeout OBJECT-TYPE
    SYNTAX          Unsigned32
    UNITS           "seconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the expiry timeout
        for the client." 
    ::= { cldccConfig 4 }

cLD11ClientCalibRssiCalibClientExpiryTimeout OBJECT-TYPE
    SYNTAX          Unsigned32
    UNITS           "seconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the expiry timeout
        for the calibrating client." 
    ::= { cldccConfig 5 }

cLD11ClientCalibRssiRfidTagExpiryTimeout OBJECT-TYPE
    SYNTAX          Unsigned32
    UNITS           "seconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the expiry timeout
        for the RFID tags." 
    ::= { cldccConfig 6 }

cLD11ClientCalibRssiRogueApExpiryTimeout OBJECT-TYPE
    SYNTAX          Unsigned32
    UNITS           "seconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the expiry timeout
        for the Rogue APs." 
    ::= { cldccConfig 7 }

cLD11ClientCalibRssiClientHalflifeTimeout OBJECT-TYPE
    SYNTAX          Unsigned32 (0..2 | 5 | 10 | 20 | 30 
    							| 60 | 90 | 120 | 180 | 300)
    UNITS           "seconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the half-life timeout
        for the client. A value of 0 indicates that
        timeout is disabled." 
    ::= { cldccConfig 8 }

cLD11ClientCalibRssiCalibClientHalflifeTimeout OBJECT-TYPE
    SYNTAX          Unsigned32 (0..2 | 5 | 10 | 20 | 30 
    							| 60 | 90 | 120 | 180 | 300)
    UNITS           "seconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the half-life timeout
        for the calibrating client. A value of 0 indicates
        that timeout is disabled." 
    ::= { cldccConfig 9 }

cLD11ClientCalibRssiRfidTagHalflifeTimeout OBJECT-TYPE
    SYNTAX          Unsigned32 (0..2 | 5 | 10 | 20 | 30 
    							| 60 | 90 | 120 | 180 | 300)
    UNITS           "seconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the half-life timeout
        for the RFID tags. A value of 0 indicates that
        timeout is disabled." 
    ::= { cldccConfig 10 }

cLD11ClientCalibRssiRogueApHalflifeTimeout OBJECT-TYPE
    SYNTAX          Unsigned32 (0..2 | 5 | 10 | 20 | 30 
    							| 60 | 90 | 120 | 180 | 300)
    UNITS           "seconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the half-life timeout
        for the Rogue APs. A value of 0 indicates that
        timeout is disabled." 
    ::= { cldccConfig 11 }

cLD11ClientCalibRfidDataEnable OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies whether the RFID tag data
        collection is enabled." 
    ::= { cldccConfig 12 }

cLD11ClientCalibRfidTimeout OBJECT-TYPE
    SYNTAX          Unsigned32
    UNITS           "seconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the RFID tag data timeout." 
    ::= { cldccConfig 13 }

cLD11ClientCalibClientMultiBandEnable OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies whether calibrating client
        uses both the bands to transmit the requests.

          true  - the calibrating client uses both the bands
                  to transmit the requests.
          false - the calibrating client uses single band
                  to transmit the requests." 
    ::= { cldccConfig 14 }

cLD11ClientCalibClientRequestEnable OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies whether calibrating client
        uses uni band or multi band to transmit the requests.

          true  - the calibrating client uses uni band or
                  multi band to transmit the requests.
          false - the calibrating client does not use
                  any band for transmitting requests." 
    ::= { cldccConfig 15 }

cLD11ClientCalibClientBurstIntervalEnable OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies whether calibrating client
        burst interval is enabled.

          true  - the calibrating client burst interval
                  is enabled.
          false - the calibrating client burst interval
                  is disabled." 
    ::= { cldccConfig 16 }

cLD11ClientCalibClientBurstInterval OBJECT-TYPE
    SYNTAX          Unsigned32
    UNITS           "seconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the burst interval of
        the calibrating client." 
    ::= { cldccConfig 17 }

cLD11ClientCalibClientInterval OBJECT-TYPE
    SYNTAX          Unsigned32
    UNITS           "seconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the notification interval
        for calibrating clients." 
    ::= { cldccConfig 18 }

cLD11ClientCalibRfidInterval OBJECT-TYPE
    SYNTAX          Unsigned32
    UNITS           "seconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the notification interval
        for RFID tags." 
    ::= { cldccConfig 19 }

cLD11ClientCalibRogueInterval OBJECT-TYPE
    SYNTAX          Unsigned32
    UNITS           "seconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the notification interval
        for Rogue APs and Rogue clients." 
    ::= { cldccConfig 20 }

cLD11RfidRssiExpiryTime OBJECT-TYPE
    SYNTAX          Unsigned32
    UNITS           "seconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the Rssi expiry time
        for RFID location tag."
    ::={ cldccConfig 21 }

cLD11RfidRssiHalflifeTime OBJECT-TYPE
    SYNTAX          Unsigned32
    UNITS           "seconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the Rssi half-life time
        for RFID location tag."
    ::={ cldccConfig 22 }

cLD11RfidNotifyThresholdTime OBJECT-TYPE
    SYNTAX          Unsigned32
    UNITS           "seconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the notify-threshold time
        for RFID tag."
    ::={ cldccConfig 24 }

cLD11RfidDataEnable OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies enable and disable the
        for RFID etag.

          true  - RFID tag collection is enabled
          false - RFID tag collection is disabled"

    ::={ cldccConfig 25 }

cLD11RfidTimeout OBJECT-TYPE
    SYNTAX          Unsigned32
    UNITS           "seconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the notify-threshold time
        for RFID tag."

    ::={ cldccConfig 26 }

-- *******************************************************************
-- *    Compliance statements
-- ********************************************************************

ciscoLwappDot11ClientCalibMIBCompliances  OBJECT IDENTIFIER
    ::= { ciscoLwappDot11ClientCalibMIBConform 1 }

ciscoLwappDot11ClientCalibMIBGroups  OBJECT IDENTIFIER
    ::= { ciscoLwappDot11ClientCalibMIBConform 2 }


-- STATUS deprecated by ciscoLwappDot11ClientCalibMIBComplianceRev1

ciscoLwappDot11ClientCalibMIBCompliance MODULE-COMPLIANCE
    STATUS          deprecated
    DESCRIPTION
        "The compliance statement for the SNMP entities that
        implement this MIB."
    MODULE          -- this module
    MANDATORY-GROUPS { ciscoLwappDot11ClientCalibMIBConfigGroup }
    ::= { ciscoLwappDot11ClientCalibMIBCompliances 1 }

ciscoLwappDot11ClientCalibMIBComplianceRev1 MODULE-COMPLIANCE
    STATUS          current
    DESCRIPTION
        "The compliance statement for the SNMP entities that
        implement this MIB."
    MODULE          -- this module
    MANDATORY-GROUPS {
                        cLD11ClientCalibClientConfigGroup,
                        cLD11ClientCalibGlobalConfigGroup,
                        cLD11ClientCalibRssiDataSampleGroup
                    }

    OBJECT          cLD11ClientCalibRowStatus
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cLD11ClientCalibBeaconIntervalExt
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cLD11ClientCalibNumberOfRadios
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cLD11ClientCalibNumberOfSamples
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cLD11ClientCalibStorageType
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cLD11ClientCalibTableMaxEntries
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cLD11ClientCalibRssiAlgorithm
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cLD11ClientCalibRssiClientExpiryTimeout
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cLD11ClientCalibRssiCalibClientExpiryTimeout
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cLD11ClientCalibRssiRfidTagExpiryTimeout
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cLD11ClientCalibRssiRogueApExpiryTimeout
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cLD11ClientCalibRssiClientHalflifeTimeout
    SYNTAX          Unsigned32 (0..2 | 5 | 10 | 20 | 30 
    							| 60 | 90 | 120 | 180 | 300)
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cLD11ClientCalibRssiCalibClientHalflifeTimeout
    SYNTAX          Unsigned32 (0..2 | 5 | 10 | 20 | 30 
    							| 60 | 90 | 120 | 180 | 300)
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cLD11ClientCalibRssiRfidTagHalflifeTimeout
    SYNTAX          Unsigned32 (0..2 | 5 | 10 | 20 | 30 
    							| 60 | 90 | 120 | 180 | 300)
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cLD11ClientCalibRssiRogueApHalflifeTimeout
    SYNTAX          Unsigned32 (0..2 | 5 | 10 | 20 | 30 
    							| 60 | 90 | 120 | 180 | 300)
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cLD11ClientCalibRfidDataEnable
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cLD11ClientCalibRfidTimeout
    SYNTAX          Unsigned32 (60..7200)
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cLD11ClientCalibClientMultiBandEnable
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cLD11ClientCalibClientRequestEnable
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cLD11ClientCalibClientBurstIntervalEnable
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cLD11ClientCalibClientBurstInterval
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cLD11ClientCalibClientInterval
    SYNTAX          Unsigned32 (1..180)
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cLD11ClientCalibRfidInterval
    SYNTAX          Unsigned32 (1..180)
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cLD11ClientCalibRogueInterval
    SYNTAX          Unsigned32 (1..180)
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."
    ::= { ciscoLwappDot11ClientCalibMIBCompliances 2 }

-- ********************************************************************
-- *    Units of conformance
-- ********************************************************************

ciscoLwappDot11ClientCalibMIBConfigGroup OBJECT-GROUP
    OBJECTS         {
                        cLD11ClientCalibBeaconInterval,
                        cLD11ClientCalibRowStatus,
                        cLD11ClientCalibTableMaxEntries
                    }
    STATUS          deprecated
    DESCRIPTION
        "This collection of objects specifies the required
        calibration parameters for the 802.11 wireless clients.
        ciscoLwappDot11ClientCalibMIBConfigGroup object is 
        superseded by cLD11ClientCalibClientConfigGroup."
    ::= { ciscoLwappDot11ClientCalibMIBGroups 1 }

cLD11ClientCalibClientConfigGroup OBJECT-GROUP
    OBJECTS         {
                        cLD11ClientCalibRowStatus,
                        cLD11ClientCalibBeaconIntervalExt,
                        cLD11ClientCalibNumberOfRadios,
                        cLD11ClientCalibNumberOfSamples,
                        cLD11ClientCalibSamplesCollected,
                        cLD11ClientCalibStorageType,
                        cLD11ClientCalibTableMaxEntries
                    }
    STATUS          current
    DESCRIPTION
        "This collection of objects providing the required
        calibration parameters for the 802.11 wireless
        clients."
    ::= { ciscoLwappDot11ClientCalibMIBGroups 2 }

cLD11ClientCalibGlobalConfigGroup OBJECT-GROUP
    OBJECTS         {
                        cLD11ClientCalibRssiAlgorithm,
                        cLD11ClientCalibRssiClientExpiryTimeout,
                        cLD11ClientCalibRssiCalibClientExpiryTimeout,
                        cLD11ClientCalibRssiRfidTagExpiryTimeout,
                        cLD11ClientCalibRssiRogueApExpiryTimeout,
                        cLD11ClientCalibRssiClientHalflifeTimeout,
                        cLD11ClientCalibRssiCalibClientHalflifeTimeout,
                        cLD11ClientCalibRssiRfidTagHalflifeTimeout,
                        cLD11ClientCalibRssiRogueApHalflifeTimeout,
                        cLD11ClientCalibRfidDataEnable,
                        cLD11ClientCalibRfidTimeout,
                        cLD11ClientCalibClientMultiBandEnable,
                        cLD11ClientCalibClientRequestEnable,
                        cLD11ClientCalibClientBurstIntervalEnable,
                        cLD11ClientCalibClientBurstInterval,
                        cLD11ClientCalibClientInterval,
                        cLD11ClientCalibRfidInterval,
                        cLD11ClientCalibRogueInterval,
                        cLD11RfidRssiExpiryTime,
                        cLD11RfidRssiHalflifeTime,
                        cLD11RfidNotifyThresholdTime,
                        cLD11RfidDataEnable,
                        cLD11RfidTimeout
                    }
    STATUS          current
    DESCRIPTION
        "This collection of objects providing the required
        RSSI calibration parameters for the 802.11 wireless 
        clients."
    ::= { ciscoLwappDot11ClientCalibMIBGroups 3 }

cLD11ClientCalibRssiDataSampleGroup OBJECT-GROUP
    OBJECTS         {
                        clD11ClientCalibDataRssiValue,
                        clD11ClientCalibDataTransmitPower
                    }
    STATUS          current
    DESCRIPTION
        "This collection of objects providing the RSSI data
        samples collected for 802.11 client."
    ::= { ciscoLwappDot11ClientCalibMIBGroups 4 }

END