-- CISCO-ENERGYWISE-MIB.my
--   
-- This MIB is used to manage CISCO Power Extensions
-- Specifications
--   
-- July 2008, Vitta Sudhir.
--   
-- Copyright (c) 2008-2010 by Cisco Systems Inc.
-- All rights reserved.
--   
-- ****************************************************************

CISCO-ENERGYWISE-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY,
    OBJECT-TYPE,
    NOTIFICATION-TYPE,
    Integer32,
    Unsigned32,
    Gauge32,
    Counter32
        FROM SNMPv2-SMI
    MODULE-COMPLIANCE,
    NOTIFICATION-GROUP,
    OBJECT-GROUP
        FROM SNMPv2-CONF
    RowStatus,
    TruthValue,
    TEXTUAL-CONVENTION,
    StorageType,
    TimeStamp,
    MacAddress
        FROM SNMPv2-TC
    InetAddress,
    InetAddressType,
    InetPortNumber
        FROM INET-ADDRESS-MIB
    SnmpAdminString
        FROM SNMP-FRAMEWORK-MIB
    entPhysicalIndex,
    entityMIBObjects
        FROM ENTITY-MIB
    EntPhysicalIndexOrZero
        FROM CISCO-TC
    ciscoMgmt
        FROM CISCO-SMI;


ciscoEnergywiseMIB MODULE-IDENTITY
    LAST-UPDATED    "201007090000Z"
    ORGANIZATION    "Cisco Systems, Inc."
    CONTACT-INFO
            "Cisco Systems
            Customer Service

            Postal: 170 W Tasman Drive
            San Jose, CA  95134
            USA

            Tel: +1 800 553-NETS

            E-mail: cs-snmp@cisco.com"
    DESCRIPTION
        "The MIB is used to manage and optimize power usage
        in networks. 

        Cisco EnergyWise is a specification of data, discovery and
        protocols for managing power on and between network devices.

        An entity is Cisco EnergyWise compatible, if it complies with
        Cisco EnergyWise specification.

        A Cisco EnergyWise entity is characterized by the power related
        attributes of a physical entity present in ENTITY-MIB. 

        Cisco EnergyWise solves the problem of Network Power
        Management.   One of goals of Cisco EnergyWise is to manage
        power on network level.  Some solutions in FCAPS have focused
        on
        managing a single element but Cisco EnergyWise provides the
        capability to handle the management of a network of devices, as
        well as a single device. 

        Concepts and Definitions:
        =========================
        Cisco EnergyWise Entity: A physical entity that is part of the
        network that provides power or draws power from another 
        part of the network.

        Cisco EnergyWise Level: A uniform way to classify power
        settings on an EnergyWise entity.  Levels are guidelines for
        the manufacturers of entity (e.g., shut, hibernate, sleep,
        standby).

        Cisco EnergyWise Usage: The consumption of power by a Cisco
        EnergyWise entity in watts.

            Current         The current power consumption by an 
                            Cisco EnergyWise entity.

            Provisioned     The maximum power a Cisco EnergyWise
                            entity can draw in the current level.

            Usage Vector    A vector 0..10 representing the maximum
                            power a Cisco EnergyWise entity can draw at
                            each level. 

            Delta Vector    This defines a vector 0..10 representing
                            the difference between the Current and
                            Usage Vector for each level.

        Cisco EnergyWise Entity Power Unit: This is used to represent
        smaller or larger quantities of Cisco EnergyWise usage and
        conforms to the standard prefixes for the SI (System
        International) units of measure.  The value represents an
        exponent of 10.

            For example, if current usage of an EnergyWise entity is 
            3, it could be 3 W, 3 mW, 3 KW, 3 MW depending on the value
            of Cisco EnergyWise power unit, i.e. 0, -3, 3, or 6 
            respectively.

        Cisco EnergyWise Domain: A collection of entities that is
        divided into manageable sets.  Switch, IP phones, IP cameras,
        lighting controllers can be Cisco EnergyWise entities, all part
        of a domain.  A domain can contain multiple devices.

        Cisco EnergyWise Entity Importance: The importance attribute of
        an entity enables the management station to differentiate other
        Cisco EnergyWise entities in the domain with a different
        business context.  This also provides a choice to the
        administrators to manage power in context of importance.

            For example, assuming we have 2 phones deployed in a
            enterprise.  One phone is in a shared spare office and one 
            used by trader generating lot of money as part of core
            business of enterprise.

            This clearly demonstrates that the phone used by trader is
            more important than the phone used in the spare office.

        Nanny Vector: A vector of bits, representing different features
        (E.g., sleep, wakeup, shutdown) supported on a Cisco
        EnergyWise entity.  Setting of some of the features on the
        Cisco EnergyWise entity can be managed by itself, but for some
        others, a parent has to nanny.

        Nanny: An EnergyWise entity acts on behalf of another 
        another Cisco EnergyWise entity.

        Cisco EnergyWise Parent: A Cisco EnergyWise entity that does
        not have a nanny vector.  This entity can manage all its power
        setting for itself as well as for Cisco EnergyWise entities
        contained in it.  The contained in relationship is same as
        defined in ENTITY-MIB. 

        Cisco EnergyWise Child: A Cisco EnergyWise entity that has a
        nanny vector.  It requires a Cisco EnergyWise parent to serve
        as nanny.  Depending on the nanny vector a Cisco EnergyWise
        child can be fully or partially managed.  

        Cisco EnergyWise Neighbor: A Cisco EnergyWise entity to which
        Cisco EnergyWise protocol events can be forwarded to.  An
        entity can either discover a neighbor using a discovery
        protocol, or the neighbor can be configured as a static
        neighbor
        by the Management station.  A Cisco EnergyWise parent may also
        nanny a Cisco EnergyWise neighbor.

            For example, A Cisco EnergyWise compatible entity like an
            IP phone, connected to a port on the switch, can provide a 
            nanny vector to the switch to serve as a nanny.

        Cisco EnergyWise Proxy: A device attached to a port that does
        not understand the Cisco EnergyWise protocol, but has the
        provision to manage power through network APIs or a proprietary
        protocol.  

        A Proxy is always configured on a port.  It allows the
        Cisco EnergyWise protocol to be used with other non networking
        devices that draw power indirectly. 

            For example, a Lutron controller (building lighting 
            controller) is a nonnetworking device which does not
            understand Cisco EnergyWise protocol.  However, it runs a 
            proprietary BACNET protocol.

        The following diagram represents the relationship between 
        cewEntTable and cewNeighborTable, 
        cewEntTable and cewProxyTable.


                              Points to a 
        --------------------- nbr entry for    ---------------------
        | EntPhyIdx | NbrId | which it does    | NbrId |  Name     |
        --------------------- Nanny            ---------------------
        | 101       |   1   |----------------->|    1  | IP-Phone1 |
        ---------------------                  ---------------------
        | 102       |   0   |                  |    2  | Switch1   |
        ---------------------                  ---------------------
        | 103       |   3   |----------------->|    3  | IP-Phone2 |
        ---------------------                  ---------------------
        | 104       |   0   |----------        |       |           |
        ---------------------         |        ---------------------
        | 105       |   0   |-----    |        |       |           |
        ---------------------    |    |        ---------------------
                                 |    |
        Points to proxy          |    |   -----------------------------
        entry configured         |    |   | EntPhyIdx | PrxyId | Name |
        on this port.            |    |  -----------------------------
                                 |    |-->|  104      |  1     | LC1  |
                                 |        -----------------------------
                                 |        |           |        |      |
                                 |        -----------------------------
                                 -------> |  105      |  3     | BL2  |
                                          -----------------------------
                                          |           |        |      |
                                          -----------------------------

        Cisco EnergyWise Event: It is a policy that can be either
        configured on a Cisco EnergyWise entity or received from
        other Cisco EnergyWise entities.  Using this, a Cisco
        EnergyWise entity can adjust its power settings according
        to some criteria, typically time.

            For example, a Management station can configure an
            EnergyWise event on a switch to control devices in branch 
            offices, to go to power level standby at 8pm and power
            level full at 7am.

        Cisco Energywise Query: It is a Cisco Energywise CLI used to
        get
        power information from the entire Energywise Domain. Queries
        are
        delivered, hop by hop, through the Domain using the established
        neighbor information. Authentication is by the domain's shared
        secret, and only authenticated queries can be sent to
        EndPoints. EnergyWise supports various kinds of queries,
        including set, collect, sum and delta.
           set: changes or turns off power usage levels
           collect: retrieves power usage information (in watts) from
        the cloud.  
           sum: aggregates power information across multiple Members
        and Endpoints. 
           delta: runs what if calculations.

        Cisco EnergyWise Neighbor Id : The Cisco EnergyWise Neighbor's
        unique Id is made up of two parts:-
            UDI: Unique Device Indentification of the Cisco EnergyWise
        Neighbor.
            EntPhysicalIndex: The Entity Physical Index of the Cisco
        EnergyWise Neighbor.
        A combination of these two values provide a unique Id for the
        Cisco EnergyWise Neighbor."
    REVISION        "201007090000Z"
    DESCRIPTION
        "Swaped the order of objects in cewEntEnergyUsageDirection and
        cewNeighborUsageDirection"
    REVISION        "201003260000Z"
    DESCRIPTION
        "The following MIB objects have been added :-
        cewNeighborMacAddress
        cewNeighborParentPortIndex
        cewNeighborEnergywiseIdIndex

        Changed MAX-ACCESS for cewEntEnergyLevel to read-only to
        correct
        error were MIB did not match design and implementation."
    REVISION        "200911220000Z"
    DESCRIPTION
        "Two new mib objects have been added :- cewEntAllowSet and
        cewEntActivityCheck."
    REVISION        "200910210000Z"
    DESCRIPTION
        "The following MIB objects have been added :-

        cewEntEnergyUsageCategory
        cewEntEnergyUsageDirection

        cewNeighborKeyword            
        cewNeighborConfiguredKeyword 
        cewNeighborName  
        cewNeighborConfiguredName
        cewNeighborRoleDescription
        cewNeighborConfiguredRoleDescription
        cewNeighborEnergyLevel
        cewNeighborConfiguredLevel
        cewNeighborImportance
        cewNeighborConfiguredImportance
        cewNeighborEnergyUnits
        cewNeighborEnergyUsage
        cewNeighborEnergyUsageCategory
        cewNeighborEnergyUsageDirection

        cewNeighborLevelTable :-

        cewNeighborLevelEntry 
        cewNeighborLevelIndex
        cewNeighborLevelMaxUsage
        cewNeighborLevelDeltaUsage
        cewNeighborLevelUnits"
    REVISION        "200905200000Z"
    DESCRIPTION
        "Following object was added to the MIB.

        cewDeviceType

        Following modifications were made

        cewNeighborDeviceType was added cewNeighborTable"
    REVISION        "200905080000Z"
    DESCRIPTION
        "Following objects were added to the MIB to provide
        support for activation of Cisco EnergyWise on a Cisco
        EnergyWise entity.

                cewManagementSecret
                cewEndPointSecret
                cewDomainSecret
                cewProtocol
                cewAddressType
                cewAddress
                cewPort
                cewEnable
                cewVersion
                cewDeviceTotalUsage
                cewDeviceTotalUsageUnits

                Following modifications were made

                cewEntConfiguredlevel added to cewEntTable.
                cewEventImportance added to cewEventTable."
    REVISION        "200901080000Z"
    DESCRIPTION
        "Initial version of this MIB module."
    ::= { ciscoMgmt 683 }


ciscoEnergywiseMIBNotifs  OBJECT IDENTIFIER
    ::= { ciscoEnergywiseMIB 0 }

ciscoEnergywiseMIBObjects  OBJECT IDENTIFIER
    ::= { ciscoEnergywiseMIB 1 }

ciscoEnergywiseMIBConform  OBJECT IDENTIFIER
    ::= { ciscoEnergywiseMIB 2 }


-- Textual Conventions

EnergywiseLevel ::= TEXTUAL-CONVENTION
    STATUS          current
    DESCRIPTION
        "An enumerated integer value that represents the value of
        Cisco EnergyWise entity level, a power setting at which a Cisco
        EnergyWise entity uses power.

            shut(1)     : An off state.  No entity features are
                          available.  The entity is unavailable.
                          No power is being consumed.

            hibernate(2): No entity features are available.  The
                          entity may be available but the time for
                          availability is longer than sleep. Minimal,
                          nearly zero, or zero power is consumed.

            sleep(3)    : No entity features are available.  The 
                          entity may be available but the time for 
                          availability is longer than standby.
                          Minimal power is consumed.

            standby(4)  : Indicates some entity features may not be
                          available.  The entity may be available 
                          but the time for availability is longer
                          than ready.  Minimal power is consumed.

            ready(5)    : Indicates some entity features may not
                          be available.  The entity itself may be
                          available but their may be a time delay
                          for availability.
                          Low or less power is consumed.

            low(6)      : Indicates some features may not be available
                          and the entity has taken measures/options to
                          provide less than frugal usage.

            frugal(7)   : Indicates some features may not be available
                          and the entity has taken measures/options to
                          provide less than medium usage.

            medium(8)   : Indicates all entity features are available 
                          but the entity has taken measures/options to
                          provide less than reduced usage.

            reduced(9)  : Indicates all entity features are available
                          but the entity has taken measures/options to
                          provide less than high usage.

            high(10)    : Indicates all entity features are available
                          and power consumption is less than full.

            full(11)    : Indicates all entity features are available
                          and the entity is consuming the highest
                          power."
    SYNTAX          INTEGER  {
                        shut(1),
                        hibernate(2),
                        sleep(3),
                        standby(4),
                        ready(5),
                        low(6),
                        frugal(7),
                        medium(8),
                        reduced(9),
                        high(10),
                        full(11)
                    }

EnergywiseId ::= TEXTUAL-CONVENTION
    STATUS          current
    DESCRIPTION
        "A unique identifier for the Cisco EnergyWise entity in the
        Cisco EnergyWise domain.  Implementation must make sure that the
        ID for each entity should be unique among all entities within
        the Cisco EnergyWise domain. 

            For example, for Cisco entities, ID is based on UDI. 
            where UDI consists of:
            PID - Product Identifier
            VID - Version Identifier
            SN  - Serial Number."
    SYNTAX          OCTET STRING (SIZE (0..32))

EnergywisePowerUnits ::= TEXTUAL-CONVENTION
    STATUS          current
    DESCRIPTION
        "An integer value that represents the units used to measure
        the power.  The units are expressed in watts."
    SYNTAX          Integer32 (-24..24)

EnergywiseKeywordList ::= TEXTUAL-CONVENTION
    STATUS          current
    DESCRIPTION
        "A list of keywords.  If multiple keywords are present, then
        this string will contain all the keywords separated by ','
        character. 

            For example, If a Cisco EnergyWise entity is tagged with 
            keywords 'building' and 'lobby', then the keyword list
            will be 'building,lobby'."
    SYNTAX          OCTET STRING (SIZE (0..255))

-- Objects

cewDeviceId OBJECT-TYPE
    SYNTAX          EnergywiseId
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates the Cisco EnergyWise identifier assigned
        to the device." 
    ::= { ciscoEnergywiseMIBObjects 1 }

cewDeviceNeighborCount OBJECT-TYPE
    SYNTAX          Gauge32
    UNITS           "neighbors"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates the current number of neighbors." 
    ::= { ciscoEnergywiseMIBObjects 2 }

cewDomainName OBJECT-TYPE
    SYNTAX          SnmpAdminString
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the domain name of the Cisco EnergyWise
        entity.  This object specifies a null string if no domain name
        is configured.

        If write access is implemented for an instance of
        cewDomainName, and a value is written into the instance, the
        agent must retain the supplied value in the cewDomainName
        instance associated with the same physical entity for as long
        as that entity remains instantiated.  This includes
        instantiations across all re-initializations/reboots of the
        network management system, including those which result in a
        change of the physical entity's entPhysicalIndex value." 
    ::= { ciscoEnergywiseMIBObjects 3 }

cewMaxImportance OBJECT-TYPE
    SYNTAX          Gauge32
    UNITS           "importance"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates the maximum importance value
        among all the Cisco EnergyWise entities in the domain." 
    ::= { ciscoEnergywiseMIBObjects 4 }

cewMaxImportanceId OBJECT-TYPE
    SYNTAX          EnergywiseId
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates the Cisco EnergyWise identifier of the
        Cisco EnergyWise entity having maximum importance in the
        domain." 
    ::= { ciscoEnergywiseMIBObjects 5 }

cewEntTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CewEntEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This table lists Cisco EnergyWise entities.  This table has a
        sparse dependent relationship on the entPhysicalTable, where
        this table contains a row for each physical entity that is Cisco
        EnergyWise compliant."
    ::= { ciscoEnergywiseMIBObjects 6 }

cewEntEntry OBJECT-TYPE
    SYNTAX          CewEntEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "An entry describes attributes of a Cisco EnergyWise entity.

        Whenever the device creates/destroys a Cisco EnergyWise 
        compliant entity, the device creates/destroys a row in the
        cewEntTable."
    INDEX           { entPhysicalIndex } 
    ::= { cewEntTable 1 }

CewEntEntry ::= SEQUENCE {
        cewEntNannyVector            BITS,
        cewEntNeighborIndex          Unsigned32,
        cewEntKeyword                EnergywiseKeywordList,
        cewEntName                   SnmpAdminString,
        cewEntRoleDescription        SnmpAdminString,
        cewEntFullName               SnmpAdminString,
        cewEntEnergyUnits            EnergywisePowerUnits,
        cewEntEnergyUsage            Unsigned32,
        cewEntEnergyUsageCaliber     INTEGER,
        cewEntEnergyLevel            EnergywiseLevel,
        cewEntEnergyUsageProvisioned Unsigned32,
        cewEntImportanceInt          Unsigned32,
        cewEntImportanceExt          Unsigned32,
        cewEntImportanceRelative     Unsigned32,
        cewEntImportanceParentId     EnergywiseId,
        cewEntParentId               EnergywiseId,
        cewEntAdminStatus            INTEGER,
        cewEntOperStatus             INTEGER,
        cewEntConfiguredLevel        EnergywiseLevel,
        cewEntEnergyUsageCategory    INTEGER,
        cewEntEnergyUsageDirection   INTEGER,
        cewEntAllowSet               TruthValue,
        cewEntActivityCheck          TruthValue
}

cewEntNannyVector OBJECT-TYPE
    SYNTAX          BITS {
                        powerWakeUp(0),
                        powerLevel1(1),
                        powerLevel2(2),
                        powerLevel3(3),
                        powerLevel4(4),
                        powerLevel5(5),
                        powerLevel6(6),
                        powerLevel7(7),
                        powerLevel8(8),
                        powerLevel9(9),
                        powerLevel10(10),
                        powerLevel11(11),
                        powerShutNWakeUp(12),
                        powerUsage(13),
                        powerImportance(14)
                    }
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates the nanny vector of the current
        Cisco EnergyWise entity.

           powerWakeUp(0):   Feature to wake up a Cisco EnergyWise
                             entity.

           powerLevel1(1):   Feature to set to power level 1(shut).

           powerLevel2(2):   Feature to set to power level
                             2(hibernate).

           powerLevel3(3):   Feature to set to power level 3(sleep).

           powerLevel4(4):   Feature to set to power level 4(standby)

           powerLevel5(5):   Feature to set to power level 5(ready).

           powerLevel6(6):   Feature to set to power level 6(low).

           powerLevel7(7):   Feature to set to power level 7(frugal).

           powerLevel8(8):   Feature to set to power level 8(medium).

           powerLevel9(9):   Feature to set to power level 9(reduced).

           powerLevel10(10): Feature to set to power level 10(high).

           powerLevel11(11): Feature to set to power level 11(full).

           powerShutNWakeUp: Feature to shutdown and wake up a Cisco 
                             EnergyWise entity.

           powerUsage:       Feature to manage Cisco EnergyWise usage of
                             a Cisco EnergyWise entity.

           powerImportance:  Feature to manage Cisco EnergyWise
                             importance of a Cisco EnergyWise entity." 
    ::= { cewEntEntry 1 }

cewEntNeighborIndex OBJECT-TYPE
    SYNTAX          Unsigned32 (1..4294967295)
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates an arbitrary unsigned integer-value that
        uniquely identifies the Cisco EnergyWise neighbor, for which the
        current Cisco EnergyWise entity serves as a nanny." 
    ::= { cewEntEntry 2 }

cewEntKeyword OBJECT-TYPE
    SYNTAX          EnergywiseKeywordList
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the EnergywiseKeywordList with which this
        entity is tagged.  This object specifies the null string if no
        keyword has been configured.

        If write access is implemented for an instance of cewEntKeyword,
        and a value is written into the instance, the agent must retain
        the supplied value in the cewEntKeyword instance associated with
        the same physical entity for as long as that entity remains
        instantiated.  This includes instantiations across all
        re-initializations/reboots of the network management system,
        including those which result in a change of the physical
        entity's entPhysicalIndex value." 
    ::= { cewEntEntry 3 }

cewEntName OBJECT-TYPE
    SYNTAX          SnmpAdminString
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies an administratively assigned human
        readable name to the Cisco EnergyWise entity.  

           For example, we can have a switch deployed to lobby
           with cewEntName as 'LL'.

        This object specifies a null string if no name is configured.

        If write access is implemented for an instance of cewEntName,
        and a value is written into the instance, the agent must retain
        the supplied value in the cewEntname instance associated with
        the same physical entity for as long as that entity remains
        instantiated.  This includes instantiations across all
        re-initializations/reboots of the network management system,
        including those which result in a change of the physical
        entity's entPhysicalIndex value." 
    ::= { cewEntEntry 4 }

cewEntRoleDescription OBJECT-TYPE
    SYNTAX          SnmpAdminString
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies an administratively assigned name to
        indicate the purpose a Cisco EnergyWise entity serves in the
        network.

           For example, we can have switches deployed to a lobby 
           with cewEntName as 'LL', cewEntRoleDescription as
           'LobbySwitch'.

        This object specifies a null string if no role description is
        configured.

        If write access is implemented for an instance of
        cewEntRoleDescription, and a value is written into the
        instance, the agent must retain the supplied value in the
        cewEntRoleDescription instance associated with the same
        physical entity for as long as that entity remains
        instantiated.  This includes instantiations across all re-
        initializations/reboots of the network management system,
        including those which result in a change of the physical
        entity's entPhysicalIndex value." 
    ::= { cewEntEntry 5 }

cewEntFullName OBJECT-TYPE
    SYNTAX          SnmpAdminString
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object specifies the full name of a Cisco EnergyWise
        entity.  This name is the combination of the cewDomainName,
        cewEntRoleDescription, cewEntName.

            For example, we can have a switch deployed to lobby with
            cewEntFullName as 'com.cisco.bldg19.LobbySwitch.LL'
            where,
            cewDomainName - gcom.cisco.bldg19
            cewEntRole - LobbySwitch
            cewEntName - LL" 
    ::= { cewEntEntry 6 }

cewEntEnergyUnits OBJECT-TYPE
    SYNTAX          EnergywisePowerUnits
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates the units of power for the Cisco
        EnergyWise entity.

        The value of this column applies to the following objects:
        cewEntEnergyUsage
        cewEntEnergyUsageProvisioned." 
    ::= { cewEntEntry 7 }

cewEntEnergyUsage OBJECT-TYPE
    SYNTAX          Unsigned32 (0..2147483647)
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates the current usage for the Cisco
        EnergyWise entity.  This should be less than or equal to
        the power that can be consumed at that specified level." 
    ::= { cewEntEntry 8 }

cewEntEnergyUsageCaliber OBJECT-TYPE
    SYNTAX          INTEGER  {
                        max(1),
                        presumed(2),
                        unknown(3),
                        actual(4),
                        trusted(5)
                    }
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object specifies the type of the usage data reported by
        cewEntityEnergyUsage.

            max: This indicates that the actual power drawn cannot be
            determined. A presumed value that is the maximum the 
            Cisco EnergyWise entity could draw is provided.

            presumed: This indicates that the actual power drawn cannot
            be determined but can be  presumed from the model.
            A dell box X draws 200W, Dell Model y draws 210W. 

            actual: This indicates that the usage data reported is not 
            presumed or max but the real power drawn.  A PoE phone
            drawing X amount of power can be determined by reading from
            the port.  A PoE phone can report the actual usage as X W. 

            unknown: This indicates that the usage reported is unknown.
            In some cases, entities report aggregate power like what a 
            lighting controller or aggregate controller does.  In such 
            cases it is not known whether the usage reported is actual
            or presumed.  

            trusted: This indicates that the usage data reported was 
            reported from another source." 
    ::= { cewEntEntry 9 }

cewEntEnergyLevel OBJECT-TYPE
    SYNTAX          EnergywiseLevel
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object specifies the current power level for the
        Cisco EnergyWise entity." 
    ::= { cewEntEntry 10 }

cewEntEnergyUsageProvisioned OBJECT-TYPE
    SYNTAX          Unsigned32 (0..2147483647)
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates the maximum power a Cisco EnergyWise
        entity can draw at current level." 
    ::= { cewEntEntry 11 }

cewEntImportanceInt OBJECT-TYPE
    SYNTAX          Unsigned32 (1..100)
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies Cisco EnergyWise importance for the
        Cisco EnergyWise entity."
    DEFVAL          { 1 } 
    ::= { cewEntEntry 12 }

cewEntImportanceExt OBJECT-TYPE
    SYNTAX          Unsigned32 (1..4294967295)
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates the sum of its own importance and
        intrinsic importance of all the entities dependent on it." 
    ::= { cewEntEntry 13 }

cewEntImportanceRelative OBJECT-TYPE
    SYNTAX          Unsigned32 (1..100)
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates the relative importance of a Cisco
        EnergyWise entity with respect to the maximum importance
        value in the domain.

        It is derived using the formula:
        (cewEntImportanceExt / cewEntMaxImportance) * 100." 
    ::= { cewEntEntry 14 }

cewEntImportanceParentId OBJECT-TYPE
    SYNTAX          EnergywiseId
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates a Cisco EnergyWise entity, which
        identifies itself as important for the current entity's
        functionality in the network.

           For example, assume a network consisting of switches, IP 
           phones and a call manager (device which supports call
           related operations in a phone).  

           Though an IP phone derives its power from the switch, it
           will not work if the call-manager is not operational.  It 
           clearly demonstrates the importance of the call-manager in
           the network.  Hence it is the parent of the IP phones in
           terms of importance.

           Given a parent and child relationship this can be read as,
           child (IP phone) needs parent (call manager).

        Importance calculations enable the management stations to
        identify the Cisco EnergyWise entities that support other
        Cisco EnergyWise entities and weigh them as more important
        to the network as a whole." 
    ::= { cewEntEntry 15 }

cewEntParentId OBJECT-TYPE
    SYNTAX          EnergywiseId
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates the Cisco EnergyWise parent of this
        entity.
        If a Cisco EnergyWise entity is a Cisco EnergyWise parent,
        then the value of this column is the null string." 
    ::= { cewEntEntry 16 }

cewEntAdminStatus OBJECT-TYPE
    SYNTAX          INTEGER  {
                        up(1),
                        down(2)
                    }
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "A control object to indicate the administratively desired state
        for the Cisco EnergyWise entity.

            up:   enables Cisco EnergyWise protocol on the entity.

            down: disables Cisco EnergyWise protocol on the entity." 
    ::= { cewEntEntry 17 }

cewEntOperStatus OBJECT-TYPE
    SYNTAX          INTEGER  {
                        up(1),
                        down(2),
                        error(3)
                    }
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates the operational status for the
        Cisco EnergyWise entity. 

        If the cewEntAdminStatus is down(2), then cewEntOperStatus
        should be down(2).

        If cewEntAdminStatus is changed to up(1), then cewEntOperStatus
        should change to up(1), unless some error has occurred, then it
        should be in error(3) state." 
    ::= { cewEntEntry 18 }

cewEntConfiguredLevel OBJECT-TYPE
    SYNTAX          EnergywiseLevel
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the level set by the network
        administrator.  The value of this object could change if the
        recurrence event is fired.

        When a network administrator sets the level of this object the
        value of cewEntEnergyLevel will change to that value if the
        configured level is successfully accepted by the system." 
    ::= { cewEntEntry 19 }

cewEntEnergyUsageCategory OBJECT-TYPE
    SYNTAX          INTEGER  {
                        consumer(1),
                        producer(2),
                        meter(3)
                    }
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object specifies the energy usage type of this Cisco
        Energywise Entity.

        consumer: This indicates that the Cisco Energywise Entity
        consumes energy.
        producer: This indicates that the Cisco Energywise Entity
        generates energy.
        meter: This indicates that the Cisco Energywise Entity is a
        meter which reads the energy consumed or produced." 
    ::= { cewEntEntry 20 }

cewEntEnergyUsageDirection OBJECT-TYPE
    SYNTAX          INTEGER {
                        out(-1),
                        in(1)
                    }
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object specifies the direction of the energy usage by this
        Cisco EnergyWise Entity, with respect to the power grid.

        out: This indicates that the power is being consumed or drawn
        out of the power grid by the Cisco EnergyWise Entity.
        in: This indicates that the power is being produced and supplied
        into the power grid by the Cisco EnergyWise Entity." 
    ::= { cewEntEntry 21 }

cewEntAllowSet OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the value of the flag used to determine
        if the Cisco Energywise Query Set is set to true/false. If the
        flag is set to true, the cli, energywise allow query set is
        activated for this Cisco Energywise Entity. 

        When its set to false, the user will be prevented from setting
        the parameters from the query. For more information on Cisco
        Energywise Queries, refer to the description above." 
    ::= { cewEntEntry 22 }

cewEntActivityCheck OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the value of the flag used to determine
        if activity check is allowed or not on this Cisco Energywise
        Entity. If the flag is set to true, Energywise allows activity
        check to be done on this Cisco Energywise Entity.Activity check
        is done to determine if an IP Phone entity connected to the
        switch is in use or not before the port can be turned OFF or
        ON." 
    ::= { cewEntEntry 23 }
 


cewLevelTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CewLevelEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This table lists the power usage at each level for each
        Cisco EnergyWise entity. 

        This table has an expansion dependent relationship on the
        cewEntTable, containing rows describing each level for the
        corresponding Cisco EnergyWise entity."
    ::= { ciscoEnergywiseMIBObjects 7 }

cewLevelEntry OBJECT-TYPE
    SYNTAX          CewLevelEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "A cewLevelEntry extends a corresponding cewEntEntry.  This
        entry displays max usage and delta values at each level.

        For example,
        Given the values of a Cisco EnergyWise entity as below:
        Level                   Usage        UsageProvisioned
        2                       11           15

        UsageVector              DeltaVector
        (0,10,15,25,35,...100)  (11, 1, -4, -14, -24,...,-89)"
    INDEX           {
                        entPhysicalIndex,
                        cewLevelIndex
                    } 
    ::= { cewLevelTable 1 }

CewLevelEntry ::= SEQUENCE {
        cewLevelIndex      EnergywiseLevel,
        cewLevelMaxUsage   Unsigned32,
        cewLevelDeltaUsage Integer32,
        cewLevelUnits      EnergywisePowerUnits
}

cewLevelIndex OBJECT-TYPE
    SYNTAX          EnergywiseLevel
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This object indicates the level for which this entry describes
        the power usage." 
    ::= { cewLevelEntry 1 }

cewLevelMaxUsage OBJECT-TYPE
    SYNTAX          Unsigned32 (0..2147483647)
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates the maximum power usage for the
        Cisco EnergyWise entity at the particular level." 
    ::= { cewLevelEntry 2 }

cewLevelDeltaUsage OBJECT-TYPE
    SYNTAX          Integer32 (-2147483648..2147483647)
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates the delta; that is the difference between
        the current cewEntityEnergyUsage and the cewLevelMaxUsage
        value of a Cisco EnergyWise entity at a level." 
    ::= { cewLevelEntry 3 }

cewLevelUnits OBJECT-TYPE
    SYNTAX          EnergywisePowerUnits
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates the Cisco EnergyWise power units for
        cewLevelMaxUsage and cewLevelDeltaUsage values." 
    ::= { cewLevelEntry 4 }
 


cewProxyTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CewProxyEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This table lists Cisco EnergyWise proxies.

        This table has an expansion dependent relationship on the
        cewEntTable, containing zero or more rows for each row in the
        cewEntTable."
    ::= { ciscoEnergywiseMIBObjects 8 }

cewProxyEntry OBJECT-TYPE
    SYNTAX          CewProxyEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "An entry describes the attributes, required to be configured
        on a Cisco EnergyWise entity to reach the Cisco EnergyWise
        proxy.

        An entry is created/deleted in cewProxyTable, whenever an
        Cisco EnergyWise entity is configured/unconfigured with above
        attributes."
    INDEX           {
                        entPhysicalIndex,
                        cewProxyId
                    } 
    ::= { cewProxyTable 1 }

CewProxyEntry ::= SEQUENCE {
        cewProxyId          Unsigned32,
        cewProxyAddressType InetAddressType,
        cewProxyAddress     InetAddress,
        cewProxyPort        InetPortNumber,
        cewProxyClass       SnmpAdminString,
        cewProxyStorage     StorageType,
        cewProxyStatus      RowStatus
}

cewProxyId OBJECT-TYPE
    SYNTAX          Unsigned32 (1..4294967295)
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This object indicates an arbitrary unsigned integer-value that
        uniquely identifies the proxy." 
    ::= { cewProxyEntry 1 }

cewProxyAddressType OBJECT-TYPE
    SYNTAX          InetAddressType
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "This object specifies the address type used for
        cewProxyAddress.

        Cisco EnergyWise proxy entries are only valid for the address
        type of ipv4(1) and ipv6(2)." 
    ::= { cewProxyEntry 2 }

cewProxyAddress OBJECT-TYPE
    SYNTAX          InetAddress
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "This object specifies the IP address of the proxy." 
    ::= { cewProxyEntry 3 }

cewProxyPort OBJECT-TYPE
    SYNTAX          InetPortNumber
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "This object specifies the port used by the proxy." 
    ::= { cewProxyEntry 4 }

cewProxyClass OBJECT-TYPE
    SYNTAX          SnmpAdminString
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "This object specifies a string which a network administrator
        can use to classify Cisco EnergyWise proxies to particular
        proxy type.

        For example, all the building controllers (Cisco EnergyWise
        proxies which understand BACNET proprietary protocol) will be
        tagged with 'BACNET' string." 
    ::= { cewProxyEntry 5 }

cewProxyStorage OBJECT-TYPE
    SYNTAX          StorageType
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "This object specifies the memory realization of a Cisco
        EnergyWise proxy."
    DEFVAL          { volatile } 
    ::= { cewProxyEntry 6 }

cewProxyStatus OBJECT-TYPE
    SYNTAX          RowStatus
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "This object indicates the status of this proxy.

        Once the entry status has been set to active(1), the entry
        cannot be modified.  The only operation possible after this is
        to delete the entry." 
    ::= { cewProxyEntry 7 }
 


cewNeighborTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CewNeighborEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This table lists Cisco EnergyWise neighbors.

        Cisco EnergyWise entity reports its connection to the network 
        via a discovery protocol.  When a new Cisco EnergyWise neighbor
        is discovered, this table is updated with the new entry.  When
        the Cisco EnergyWise neighbor looses its connection,
        corresponding neighbor entry is deleted from the table."
    ::= { ciscoEnergywiseMIBObjects 9 }

cewNeighborEntry OBJECT-TYPE
    SYNTAX          CewNeighborEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "An entry in the cewNeighborTable.

        An entry describes the attributes of the Cisco EnergyWise 
        neighbor, either discovered through a discovery protocol
        or has been added as a static neighbor by the management
        station."
    INDEX           { cewNeighborIndex } 
    ::= { cewNeighborTable 1 }

CewNeighborEntry ::= SEQUENCE {
        cewNeighborIndex                Unsigned32,
        cewNeighborId                   EnergywiseId,
        cewNeighborType                 INTEGER,
        cewNeighborHeartBeat            TimeStamp,
        cewNeighborStorage              StorageType,
        cewNeighborStatus               RowStatus,
        cewNeighborDeviceType           SnmpAdminString,
        cewNeighborKeyword              EnergywiseKeywordList,
        cewNeighborConfiguredKeyword    EnergywiseKeywordList,
        cewNeighborName                 SnmpAdminString,
        cewNeighborConfiguredName       SnmpAdminString,
        cewNeighborRoleDescription      SnmpAdminString,
        cewNeighborConfiguredRoleDesc   SnmpAdminString,
        cewNeighborEnergyLevel          EnergywiseLevel,
        cewNeighborConfiguredLevel      EnergywiseLevel,
        cewNeighborImportance           Unsigned32,
        cewNeighborConfiguredImportance Unsigned32,
        cewNeighborEnergyUnits          EnergywisePowerUnits,
        cewNeighborEnergyUsage          Unsigned32,
        cewNeighborEnergyUsageCategory  INTEGER,
        cewNeighborEnergyUsageDirection INTEGER,
        cewNeighborMacAddress           MacAddress,
        cewNeighborPhysicalEntityId     EntPhysicalIndexOrZero,
        cewNeighborParentPortIndex      EntPhysicalIndexOrZero
}

cewNeighborIndex OBJECT-TYPE
    SYNTAX          Unsigned32 (1..4294967295)
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This object indicates an arbitrary unsigned integer-value
        that uniquely identifies the Cisco EnergyWise neighbor." 
    ::= { cewNeighborEntry 1 }

cewNeighborId OBJECT-TYPE
    SYNTAX          EnergywiseId
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "This object specifies the Cisco EnergyWise identifier of the
        neighbor." 
    ::= { cewNeighborEntry 2 }

cewNeighborType OBJECT-TYPE
    SYNTAX          INTEGER  {
                        static(1),
                        dynamic(2),
                        child(3)
                    }
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object specifies the type of a Cisco EnergyWise neighbor

        static  : specifies a neighbor which is added statically.

        dynamic : specifies a neighbor added dynamically, by a 
                  discovery protocol.

        child   : specifies a neighbor which needs a parent to nanny." 
    ::= { cewNeighborEntry 3 }

cewNeighborHeartBeat OBJECT-TYPE
    SYNTAX          TimeStamp
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates the value of sysUpTime the last time
        a heartbeat was received from the neighbor Cisco EnergyWise
        entity." 
    ::= { cewNeighborEntry 4 }

cewNeighborStorage OBJECT-TYPE
    SYNTAX          StorageType
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "This object specifies the memory realization of a Cisco
        EnergyWise neighbor."
    DEFVAL          { volatile } 
    ::= { cewNeighborEntry 5 }

cewNeighborStatus OBJECT-TYPE
    SYNTAX          RowStatus
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "This object indicates the status of this neighbor.

        Once the entry status has been set to active(1), the entry
        cannot be modified.  The only operation possible after this is
        to delete the entry." 
    ::= { cewNeighborEntry 6 }

cewNeighborDeviceType OBJECT-TYPE
    SYNTAX          SnmpAdminString
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object specifies the device type of the Cisco EnergyWise
        neighbor. This object should be same as the cewDeviceType of
        the neighbor." 
    ::= { cewNeighborEntry 7 }

cewNeighborKeyword OBJECT-TYPE
    SYNTAX          EnergywiseKeywordList
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object specifies the EnergywiseKeywordList with
        which this Cisco Energywise endpoint neighbor entity is tagged.

        If cewNeighborConfiguredKeyword is successfully changed, the
        new value will be copied over to cewNeighborKeyword to make both
        the objects have the same value. This object specifies the null
        string if no keyword has been configured." 
    ::= { cewNeighborEntry 8 }

cewNeighborConfiguredKeyword OBJECT-TYPE
    SYNTAX          EnergywiseKeywordList
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "This object specifies the keyword configured by the network
        administrator on the adjacent Cisco energywise neighbor/child
        entity.
        If the neighbor is of type child and a keyword is configured,
        the switch will attempt to set the endpoint neighbor/child
        entity with this value. If the set operation is successful,
        cewNeighborKeyword will be set with the configured keyword.

        This object specifies the EnergywiseKeywordList with which
        current Cisco Energywise neighbor/endpoint entity is tagged.
        This object specifies the null string if no keyword has been
        configured.

        If write access is implemented for an instance of
        cewNeighborConfiguredKeyword, and a value is written into the
        instance,the agent must retain the supplied value in the
        cewNeighborConfiguredKeyword instance associated with the same
        physical entity for as long as that entity remains instantiated.
        This includes instantiations across all
        re-initializations/reboots of the network management system,
        including those which result in a
        change of the physical entity's entPhysicalIndex value." 
    ::= { cewNeighborEntry 9 }

cewNeighborName OBJECT-TYPE
    SYNTAX          SnmpAdminString
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object specifies an administratively assigned
        human readable name to the Cisco Energywise endpoint
        neighbor/child. If cewNeighborConfiguredName is successfully
        changed, the new value will be copied over to cewNeighborName to
        make both the objects have the same value. This object specifies
        a null string if no name is configured." 
    ::= { cewNeighborEntry 10 }

cewNeighborConfiguredName OBJECT-TYPE
    SYNTAX          SnmpAdminString
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "This object specifies the name configured on the adjacent
        Cisco Energywise neighbor/child entity. If the neighbor is of
        type child and a name is configured, the switch will attempt to
        set the endpoint neighbor/child entity with this value. If
        successful,cewNeighborName will be set with the configured name.

        This object specifies a null string if no name is configured.
        If write access is implemented for an instance of
        cewNeighborConfiguredName, and a value is written into the
        instance, the agent must retain the supplied value in the
        cewNeighborConfiguredName instance associated with the same
        physical entity for as long as that entity remains
        instantiated. This includes instantiations across all
        re-initializations/reboots of the network management
        system, including those which result in a change of the
        physical entity's entPhysicalIndex value." 
    ::= { cewNeighborEntry 11 }

cewNeighborRoleDescription OBJECT-TYPE
    SYNTAX          SnmpAdminString
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object specifies an administratively assigned
        name to indicate the purpose the Cisco Energywise endpoint
        neighbor/child serves in the network.If
        cewNeighborConfiguredRoleDesc is
        successfully changed, the new value will be copied over to
        cewNeighborRoleDescription to make both the objects have the
        same value. This object specifies a null string if no role
        description is configured." 
    ::= { cewNeighborEntry 12 }

cewNeighborConfiguredRoleDesc OBJECT-TYPE
    SYNTAX          SnmpAdminString
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "This object specifies the role configured on the adjacent
        Cisco Energywise neighbor/child entity.If the neighbor is of
        type child and a role is configured, the switch will attempt to
        set the endpoint neighbor/child entity with this value. If
        successful,       
        cewNeighborRoleDesc will be set with the configured role.

        This object specifies an administratively assigned name to
        indicate the purpose a Cisco EnergyWise entity serves in the
        network.      

        This object specifies a null string if no role description is
        configured.

        If write access is implemented for an instance of
        cewNeighborConfiguredRoleDesc, and a value is written into the
        instance, the agent must retain the supplied value in the
        cewNeighborConfiguredRoleDesc instance associated with the same
        physical entity for as long as that entity remains instantiated.
        This includes instantiations across all
        re-initializations/reboots
        of the network management system, including those which result
        in
        a change of the physical entity's entPhysicalIndex value." 
    ::= { cewNeighborEntry 13 }

cewNeighborEnergyLevel OBJECT-TYPE
    SYNTAX          EnergywiseLevel
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object specifies the current power level for the
        Cisco EnergyWise neighbor/child entity." 
    ::= { cewNeighborEntry 14 }

cewNeighborConfiguredLevel OBJECT-TYPE
    SYNTAX          EnergywiseLevel
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "This object specifies the level configured on the adjacent
        Cisco Energywise neighbor/child entity. If the neighbor is of
        type child and a level is configured, the switch will attempt to
        set the endpoint neighbor/child entity with this value. If
        successful,
        cewNeighborEnergyLevel will be set with the configured level." 
    ::= { cewNeighborEntry 15 }

cewNeighborImportance OBJECT-TYPE
    SYNTAX          Unsigned32 (1..100)
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object specifies Cisco EnergyWise importance for the
        Cisco EnergyWise neighbor/child entity."
    DEFVAL          { 1 } 
    ::= { cewNeighborEntry 16 }

cewNeighborConfiguredImportance OBJECT-TYPE
    SYNTAX          Unsigned32 (1..100)
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "This object specifies the importance configured on the adjacent
        Cisco Energywise neighbor/child entity. If the neighbor is of
        type child and the importance is configured, the switch will
        attempt to set the endpoint neighbor/child entity with this
        value. If successful, cewNeighborImportance will be set with
        the configured importance."
    DEFVAL          { 1 } 
    ::= { cewNeighborEntry 17 }

cewNeighborEnergyUnits OBJECT-TYPE
    SYNTAX          EnergywisePowerUnits
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates the units of power for the Cisco
        Energywise neighbor/child entity. The value of this column
        applies to the following objects:
        cewNeighborEnergyUsage" 
    ::= { cewNeighborEntry 18 }

cewNeighborEnergyUsage OBJECT-TYPE
    SYNTAX          Unsigned32 (0..2147483647)
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates the current usage for the Cisco
        EnergyWise neighbor/child entity.  This should be less than or
        equal to the power that can be consumed at that specified
        level." 
    ::= { cewNeighborEntry 19 }

cewNeighborEnergyUsageCategory OBJECT-TYPE
    SYNTAX          INTEGER  {
                        consumer(1),
                        producer(2),
                        meter(3)
                    }
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object specifies the energy usage type of the
        Cisco Energywise neighbor/child entity.

        consumer: This indicates that the neighbor consumes energy.
        producer: This indicates that the neighbor generates energy.
        meter: This indicates that the neighbor is a meter which reads
        the energy consumed or produced." 
    ::= { cewNeighborEntry 20 }

cewNeighborEnergyUsageDirection OBJECT-TYPE
    SYNTAX          INTEGER {
                        out(-1),
                        in(1)
                    }
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object specifies the direction of the energy usage with
        respect to the power grid for this Cisco Energywise neighbor
        entity.
        Example: A solar panel is a consumer, drawing power during some
        part of the day, taking in power from the grid. It can also
        generate power out to the grid at other times. 

        out: This indicates that the power is being consumed or drawn
        out by the Cisco EnergyWise neighbor entity.
        in: This indicates that the power is being produced and supplied
        back into the power grid by the Cisco EnergyWise neighbor
        entity." 
    ::= { cewNeighborEntry 21 }

cewNeighborMacAddress OBJECT-TYPE
    SYNTAX          MacAddress
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object specifies the MAC Address of the Cisco EnergyWise
        endpoint that is connected to the Cisco EnergyWise Entity." 
    ::= { cewNeighborEntry 22 }

cewNeighborPhysicalEntityId OBJECT-TYPE
    SYNTAX          EntPhysicalIndexOrZero
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object specifies the entity physical index of the Cisco
        Energywise Neighbor. If the neighbor is not a cisco device that
        supports the cisco entity MIB, this value will be zero." 
    ::= { cewNeighborEntry 23 }

cewNeighborParentPortIndex OBJECT-TYPE
    SYNTAX          EntPhysicalIndexOrZero
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object specifies the entPhysicalIndex of the interface
        on the switch to which the Cisco EnergyWise endpoint is 
        connected." 
    ::= { cewNeighborEntry 24 }
 


cewEventTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CewEventEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This table lists Cisco EnergyWise events.

        This table has an expansion dependent relationship on the
        cewEntTable, containing zero or more rows for each row in the
        cewEntTable."
    ::= { ciscoEnergywiseMIBObjects 10 }

cewEventEntry OBJECT-TYPE
    SYNTAX          CewEventEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "An entry describes the attributes, required to be configured
        on a Cisco EnergyWise entity, to trigger the Cisco EnergyWise
        event.

        An entry is created/deleted in cewEventTable, whenever an
        Cisco EnergyWise entity is configured/unconfigured with
        above attributes."
    INDEX           {
                        entPhysicalIndex,
                        cewEventIndex
                    } 
    ::= { cewEventTable 1 }

CewEventEntry ::= SEQUENCE {
        cewEventIndex      Unsigned32,
        cewEventLevel      EnergywiseLevel,
        cewEventRecurrence TruthValue,
        cewEventTime       SnmpAdminString,
        cewEventStorage    StorageType,
        cewEventStatus     RowStatus,
        cewEventImportance Unsigned32
}

cewEventIndex OBJECT-TYPE
    SYNTAX          Unsigned32 (1..4294967295)
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This object specifies an arbitrary unsigned
        integer-value that uniquely identifies the Cisco EnergyWise
        event." 
    ::= { cewEventEntry 1 }

cewEventLevel OBJECT-TYPE
    SYNTAX          EnergywiseLevel
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "This object specifies the level at which a Cisco EnergyWise
        entity is set for an event." 
    ::= { cewEventEntry 2 }

cewEventRecurrence OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "This object specifies whether an event is a recurring
        event. 

            true:  If this policy is a recurring event.

            false: If this policy is not a recurring event."
    DEFVAL          { true } 
    ::= { cewEventEntry 3 }

cewEventTime OBJECT-TYPE
    SYNTAX          SnmpAdminString
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "This object specifies a string-value describing the details
        regarding the time at which the event should get triggered.

            For example, 
            00:30 Hrs  on Jan, June & Dec, every weekday (Mon-Fri)
            30     0    *   1,6,12  1-5     

            *     *     *     *     *  command to be executed
            -     -     -     -     -
            |     |     |     |     |
            |     |     |     |     +----- day of week (0 - 6) Sunday=0
            |     |     |     +------- month (1 - 12)
            |     |     +--------- day of month (1 - 31)
            |     +----------- hour (0 - 23)
            +------------- min (0 - 59)

        Other management interfaces (e.g., local console) will configure
        time in the above manner.  cewEventTime can also have wild cards
        as shown in the above example." 
    ::= { cewEventEntry 4 }

cewEventStorage OBJECT-TYPE
    SYNTAX          StorageType
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "This object specifies the memory realization of a Cisco
        EnergyWise event."
    DEFVAL          { volatile } 
    ::= { cewEventEntry 5 }

cewEventStatus OBJECT-TYPE
    SYNTAX          RowStatus
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "This object indicates the status of this event.

        Once the entry status has been set to active(1), the entry
        cannot be modified.  The only operation possible after this is
        to delete the entry." 
    ::= { cewEventEntry 6 }

cewEventImportance OBJECT-TYPE
    SYNTAX          Unsigned32 (1..100)
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "This object specifies the importance at which a Cisco
        EnergyWise entity is set for an event." 
    ::= { cewEventEntry 7 }
 


cewLevelChangeNotifEnable OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies whether to enable/disable the
        cewLevelChange notification." 
    ::= { ciscoEnergywiseMIBObjects 11 }

cewNeighborAddedNotifEnable OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies whether to enable/disable the
        cewNeighborAdded notification." 
    ::= { ciscoEnergywiseMIBObjects 12 }

cewNeighborDeletedNotifEnable OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies whether to enable/disable the
        cewNeighborDeleted notification." 
    ::= { ciscoEnergywiseMIBObjects 13 }

cewEventOccuredNotifEnable OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies whether to enable/disable the
        cewEventOccured notification." 
    ::= { ciscoEnergywiseMIBObjects 14 }

cewEventOccuredErrorCode OBJECT-TYPE
    SYNTAX          INTEGER  {
                        noerror(1),
                        wrongtype(2),
                        outofrange(3),
                        swfault(4),
                        hwfault(5)
                    }
    MAX-ACCESS      accessible-for-notify
    STATUS          current
    DESCRIPTION
        "An enumerated integer value that represents different
        error codes when an event occurs.
            noerror(1)    : Event occurred without any error.
            wrongtype(2)  : Event was set with wrong value.
            outofrange(3) : Set on event called with out of range
                            values.
            swfault(4)    : Event encountered a software fault.
            hwfault(5)    : Event encountered a hardware fault." 
    ::= { ciscoEnergywiseMIBObjects 15 }

cewManagementSecret OBJECT-TYPE
    SYNTAX          SnmpAdminString
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the shared secret used to allow
        Management station to authenticate itself to connect to
        current Cisco EnergyWise entity via the management port over
        different type of protocols like HTTP, SSH.

        This object should be set by the user or network administrator
        with very high access control using only SNMPv3 protocol with
        authentication and privilege options." 
    ::= { ciscoEnergywiseMIBObjects 16 }

cewEndPointSecret OBJECT-TYPE
    SYNTAX          SnmpAdminString
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the shared secret used to allow endpoints
        to authenticate messages that are send between current Cisco
        EnergyWise entity and discovered endpoints.

        An endpoint is a device having the capability to receive and
        respond Cisco EnergyWise communication messages.

           For example, A Desktop PC or a Laptop connected to port of
           a switch is an endpoint.

        This object should be set by the user or network administrator
        with very high access control using only SNMPv3 protocol with
        authentication and privilege options." 
    ::= { ciscoEnergywiseMIBObjects 17 }

cewDomainSecret OBJECT-TYPE
    SYNTAX          SnmpAdminString
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the shared secret used by all the Cisco
        EnergyWise entities to determine their membership with a domain
        specified by cewDomainName.

        All the communications between the Cisco EnergyWise entities
        will be authorized based this object to keep the communication
        secure.

        This object should be set by the user or network administrator
        with very high access control using only SNMPv3 protocol with
        authentication and privilege options." 
    ::= { ciscoEnergywiseMIBObjects 18 }

cewProtocol OBJECT-TYPE
    SYNTAX          INTEGER  {
                        udp(1)
                    }
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the protocol used for communication
        between Cisco EnergyWise entities." 
    ::= { ciscoEnergywiseMIBObjects 19 }

cewAddressType OBJECT-TYPE
    SYNTAX          InetAddressType
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the address type used for
        cewAddress.

        Cisco EnergyWise is only valid for the address
        type of ipv4(1) and ipv6(2)." 
    ::= { ciscoEnergywiseMIBObjects 20 }

cewAddress OBJECT-TYPE
    SYNTAX          InetAddress
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the IP address of the interface that
        sends EnergyWise communication messages." 
    ::= { ciscoEnergywiseMIBObjects 21 }

cewPort OBJECT-TYPE
    SYNTAX          InetPortNumber
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the port number used for sending and
        receiving the Cisco EnergyWise communication messages." 
    ::= { ciscoEnergywiseMIBObjects 22 }

cewEnable OBJECT-TYPE
    SYNTAX          INTEGER  {
                        enable(1),
                        disable(2)
                    }
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "A control object to activate/de-activate Cisco EnergyWise
        protocol at global level on a Cisco EnergyWise entity
        (e.g. Switch).

        This object should be set to enable state only when the
        following objects are set:
            cewDomainName
            cewDomainSecret
            cewProtocol
            cewPort
            cewAddressType
            cewAddress

            enable:  enables Cisco EnergyWise protocol at a global
                     level on a Cisco EnergyWise entity.

            disable: disables Cisco EnergyWise protocol at a global
                     level on a Cisco EnergyWise entity." 
    ::= { ciscoEnergywiseMIBObjects 23 }

cewVersion OBJECT-TYPE
    SYNTAX          SnmpAdminString
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object specifies the current version of the Cisco
        EnergyWise software running on a Cisco Energywise Entity." 
    ::= { ciscoEnergywiseMIBObjects 24 }

cewDeviceTotalUsage OBJECT-TYPE
    SYNTAX          Unsigned32 (0..2147483647)
    UNITS           "watts"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates the sum of the cewEntEnergyUsage of the
        current Cisco EnergyWise entity and the cewEntEnergyUsage of
        all its children." 
    ::= { ciscoEnergywiseMIBObjects 25 }

cewDeviceTotalUsageUnits OBJECT-TYPE
    SYNTAX          EnergywisePowerUnits
    UNITS           "watts"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates the units of power for
        cewDeviceTotalUsage." 
    ::= { ciscoEnergywiseMIBObjects 26 }

cewDeviceType OBJECT-TYPE
    SYNTAX          SnmpAdminString
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object specifies the type of the Cisco EnergyWise
        device." 
    ::= { ciscoEnergywiseMIBObjects 27 }

cewAllowSet OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "When this object is set to true, the cli, energywise allow
        query set is activated for the Cisco Energywise Entity. 

        When its set to false, the user will be prevented from setting
        the parameters from the query." 
    ::= { ciscoEnergywiseMIBObjects 28 }

cewNeighborLevelTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CewNeighborLevelEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This table lists the power usage at each level for each
        Cisco EnergyWise neighbor entity. 

        This table has an expansion dependent relationship on the
        cewNeighborTable, containing rows describing each level for the
        corresponding Cisco EnergyWise neighbor entity."
    ::= { ciscoEnergywiseMIBObjects 29 }

cewNeighborLevelEntry OBJECT-TYPE
    SYNTAX          CewNeighborLevelEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "A cewNeighborLevelEntry extends a corresponding
        cewNeighborEntry.  This entry displays max usage and delta
        values at each level.

        For example,
        Given the values of a Cisco EnergyWise Neighbor entity as below:
        Level                   Usage        UsageProvisioned
        2                       11           15

        UsageVector              DeltaVector
        (0,10,15,25,35,...100)  (11, 1, -4, -14, -24,...,-89)"
    INDEX           {
                        cewNeighborIndex,
                        cewNeighborLevelIndex
                    } 
    ::= { cewNeighborLevelTable 1 }

CewNeighborLevelEntry ::= SEQUENCE {
        cewNeighborLevelIndex      EnergywiseLevel,
        cewNeighborLevelMaxUsage   Unsigned32,
        cewNeighborLevelDeltaUsage Integer32,
        cewNeighborLevelUnits      EnergywisePowerUnits
}

cewNeighborLevelIndex OBJECT-TYPE
    SYNTAX          EnergywiseLevel
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This object indicates the level for which this neighbor
        describes the power usage." 
    ::= { cewNeighborLevelEntry 1 }

cewNeighborLevelMaxUsage OBJECT-TYPE
    SYNTAX          Unsigned32 (0..2147483647)
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates the maximum power usage for the
        Cisco EnergyWise neighbor at the particular level." 
    ::= { cewNeighborLevelEntry 2 }

cewNeighborLevelDeltaUsage OBJECT-TYPE
    SYNTAX          Integer32 (-2147483648..2147483647)
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates the delta; that is the difference between
        the current cewNeighborEnergyUsage and the
        cewNeighborLevelMaxUsage value of the Cisco EnergyWise neighbor
        at a level." 
    ::= { cewNeighborLevelEntry 3 }

cewNeighborLevelUnits OBJECT-TYPE
    SYNTAX          EnergywisePowerUnits
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "This object indicates the Cisco EnergyWise power units for
        cewNeighborLevelMaxUsage
        cewNeighborLevelDeltaUsage" 
    ::= { cewNeighborLevelEntry 4 }
 


-- Notifications

cewLevelChange NOTIFICATION-TYPE
    OBJECTS         { cewEntEnergyLevel }
    STATUS          current
    DESCRIPTION
        "The SNMP entity generates the cewLevelChange when
        the value of cewEntityEnergyLevel has changed."
   ::= { ciscoEnergywiseMIBNotifs 1 }

cewNeighborAdded NOTIFICATION-TYPE
    OBJECTS         {
                        cewNeighborId,
                        cewNeighborType
                    }
    STATUS          current
    DESCRIPTION
        "The SNMP entity generates a ceweighborAdded when
        it discovers a Cisco EnergyWise entity neighbor."
   ::= { ciscoEnergywiseMIBNotifs 2 }

cewNeighborDeleted NOTIFICATION-TYPE
    OBJECTS         {
                        cewNeighborId,
                        cewNeighborType
                    }
    STATUS          current
    DESCRIPTION
        "The SNMP entity generates a cewNeighborDeleted trap when an
        Cisco EnergyWise entity neighbor is deleted.  A neighbor can
        be deleted in the following ways:

        1. The neighbor lost its connection with the current Cisco 
        EnergyWise entity.

        2. The management station deletes a neighbor entry.

        3. Another management interfaces (e.g., local console)
        deletes the static neighbor."
   ::= { ciscoEnergywiseMIBNotifs 3 }

cewEventOccured NOTIFICATION-TYPE
    OBJECTS         {
                        cewEventLevel,
                        cewEventOccuredErrorCode
                    }
    STATUS          deprecated
    DESCRIPTION
        "The SNMP entity generates cewEventOccured when an
        Cisco EnergyWise event occurs."
   ::= { ciscoEnergywiseMIBNotifs 4 }

cewEventOccuredRev1 NOTIFICATION-TYPE
    OBJECTS         {
                        cewEventLevel,
                        cewEventImportance,
                        cewEventOccuredErrorCode
                    }
    STATUS          current
    DESCRIPTION
        "The SNMP entity generates cewEventOccured when an
        Cisco EnergyWise event occurs."
   ::= { ciscoEnergywiseMIBNotifs 5 }
-- Conformance

ciscoEnergywiseMIBCompliances  OBJECT IDENTIFIER
    ::= { ciscoEnergywiseMIBConform 1 }

ciscoEnergywiseMIBGroups  OBJECT IDENTIFIER
    ::= { ciscoEnergywiseMIBConform 2 }


ciscoEnergywiseMIBFullCompliance MODULE-COMPLIANCE
    STATUS          deprecated
    DESCRIPTION
        "When this MIB is implemented with support for
        read-create, then such an implementation can 
        claim full compliance. Such devices can then 
        be both monitored and configured with this MIB."
    MODULE          -- this module
    MANDATORY-GROUPS {
                        ciscoEnergywiseEntityGroup,
                        ciscoEnergywiseNeighborGroup,
                        ciscoEnergywiseEventGroup,
                        ciscoEnergywiseNotifGroup,
                        ciscoEnergywiseNotifEnableGroup
                    }

    GROUP           ciscoEnergywiseProxyGroup
    DESCRIPTION
        "This group is optional. All the Cisco EnergyWise entities
        may not be able to provide Cisco EnergyWise proxy support."

    OBJECT          cewProxyStatus
    SYNTAX          RowStatus
    DESCRIPTION
        "Support for createAndWait and notInService is not required."

    OBJECT          cewNeighborStatus
    SYNTAX          RowStatus
    DESCRIPTION
        "Support for createAndWait and notInService is not required."

    OBJECT          cewEventStatus
    SYNTAX          RowStatus
    DESCRIPTION
        "Support for createAndWait and notInService is not required."
    ::= { ciscoEnergywiseMIBCompliances 1 }

ciscoEnergywiseMIBReadOnlyCompliance MODULE-COMPLIANCE
    STATUS          deprecated
    DESCRIPTION
        "When this MIB is implemented without support for
        read-create (i.e. in read-only mode), then such an 
        implementation can claim read-only compliance.  Such a 
        device can then be monitored but can not be configured
        with this MIB."
    MODULE          -- this module
    MANDATORY-GROUPS {
                        ciscoEnergywiseEntityGroup,
                        ciscoEnergywiseNeighborGroup,
                        ciscoEnergywiseEventGroup,
                        ciscoEnergywiseNotifGroup,
                        ciscoEnergywiseNotifEnableGroup
                    }

    GROUP           ciscoEnergywiseProxyGroup
    DESCRIPTION
        "This group is optional. All the Cisco EnergyWise entities
        may not be able to provide Cisco EnergyWise proxy support."

    OBJECT          cewDomainName
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntKeyword
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntRoleDescription
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntName
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntEnergyLevel
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntImportanceInt
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntAdminStatus
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewProxyStatus
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required, and active is the
        only status that needs to be supported."

    OBJECT          cewNeighborStatus
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required, and active is the
        only status that needs to be supported."

    OBJECT          cewEventStatus
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required, and active is the
        only status that needs to be supported."
    ::= { ciscoEnergywiseMIBCompliances 2 }

ciscoEnergywiseMIBFullComplianceRev1 MODULE-COMPLIANCE
    STATUS          deprecated
    DESCRIPTION
        "When this MIB is implemented with support for
        read-create, then such an implementation can 
        claim full compliance. Such devices can then 
        be both monitored and configured with this MIB."
    MODULE          -- this module
    MANDATORY-GROUPS {
                        ciscoEnergywiseEntityGroup,
                        ciscoEnergywiseNeighborGroup,
                        ciscoEnergywiseEventGroup,
                        ciscoEnergywiseNotifEnableGroup,
                        ciscoEnergywiseActivationGroup,
                        ciscoEnergywiseEntityGroupSup1,
                        ciscoEnergywiseEventGroupSup1,
                        cewEnergywiseNotifGroupRev1
                    }

    GROUP           ciscoEnergywiseProxyGroup
    DESCRIPTION
        "This group is optional. All the Cisco EnergyWise entities
        may not be able to provide Cisco EnergyWise proxy support."

    OBJECT          cewProxyStatus
    SYNTAX          RowStatus
    DESCRIPTION
        "Support for createAndWait and notInService is not required."

    OBJECT          cewNeighborStatus
    SYNTAX          RowStatus
    DESCRIPTION
        "Support for createAndWait and notInService is not required."

    OBJECT          cewEventStatus
    SYNTAX          RowStatus
    DESCRIPTION
        "Support for createAndWait and notInService is not required."
    ::= { ciscoEnergywiseMIBCompliances 3 }

ciscoEnergywiseMIBReadOnlyComplianceRev1 MODULE-COMPLIANCE
    STATUS          deprecated
    DESCRIPTION
        "When this MIB is implemented without support for
        read-create (i.e. in read-only mode), then such an 
        implementation can claim read-only compliance.  Such a 
        device can then be monitored but can not be configured 
        with this MIB."
    MODULE          -- this module
    MANDATORY-GROUPS {
                        ciscoEnergywiseEntityGroup,
                        ciscoEnergywiseNeighborGroup,
                        ciscoEnergywiseEventGroup,
                        ciscoEnergywiseNotifEnableGroup,
                        ciscoEnergywiseActivationGroup,
                        ciscoEnergywiseEntityGroupSup1,
                        ciscoEnergywiseEventGroupSup1,
                        cewEnergywiseNotifGroupRev1
                    }

    GROUP           ciscoEnergywiseProxyGroup
    DESCRIPTION
        "This group is optional. All the Cisco EnergyWise entities
        may not be able to provide Cisco EnergyWise proxy support."

    OBJECT          cewDomainName
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewDomainSecret
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewProtocol
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewAddressType
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewAddress
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewPort
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEnable
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntKeyword
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntRoleDescription
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntName
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntEnergyLevel
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntImportanceInt
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntAdminStatus
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewProxyStatus
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required, and active is the
        only status that needs to be supported."

    OBJECT          cewNeighborStatus
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required, and active is the
        only status that needs to be supported."

    OBJECT          cewEventStatus
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required, and active is the
        only status that needs to be supported."

    OBJECT          cewManagementSecret
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEndPointSecret
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."
    ::= { ciscoEnergywiseMIBCompliances 4 }

ciscoEnergywiseMIBFullComplianceRev2 MODULE-COMPLIANCE
    STATUS          deprecated
    DESCRIPTION
        "When this MIB is implemented with support for
        read-create, then such an implementation can 
        claim full compliance. Such devices can then 
        be both monitored and configured with this MIB."
    MODULE          -- this module
    MANDATORY-GROUPS {
                        ciscoEnergywiseEntityGroup,
                        ciscoEnergywiseNeighborGroup,
                        ciscoEnergywiseEventGroup,
                        ciscoEnergywiseNotifEnableGroup,
                        ciscoEnergywiseActivationGroup,
                        ciscoEnergywiseEntityGroupSup1,
                        ciscoEnergywiseEventGroupSup1,
                        cewEnergywiseNotifGroupRev1,
                        ciscoEnergywiseEntityGroupSup2,
                        ciscoEnergywiseNeighborGroupSup1
                    }

    GROUP           ciscoEnergywiseProxyGroup
    DESCRIPTION
        "This group is optional. All the Cisco EnergyWise entities
        may not be able to provide Cisco EnergyWise proxy support."

    OBJECT          cewProxyStatus
    SYNTAX          RowStatus
    DESCRIPTION
        "Support for createAndWait and notInService is not required."

    OBJECT          cewNeighborStatus
    SYNTAX          RowStatus
    DESCRIPTION
        "Support for createAndWait and notInService is not required."

    OBJECT          cewEventStatus
    SYNTAX          RowStatus
    DESCRIPTION
        "Support for createAndWait and notInService is not
        required."
    ::= { ciscoEnergywiseMIBCompliances 5 }

ciscoEnergywiseMIBReadOnlyComplianceRev2 MODULE-COMPLIANCE
    STATUS          deprecated
    DESCRIPTION
        "When this MIB is implemented without support for
        read-create (i.e. in read-only mode), then such an 
        implementation can claim read-only compliance.  Such a 
        device can then be monitored but can not be configured 
        with this MIB."
    MODULE          -- this module
    MANDATORY-GROUPS {
                        ciscoEnergywiseEntityGroup,
                        ciscoEnergywiseNeighborGroup,
                        ciscoEnergywiseEventGroup,
                        ciscoEnergywiseNotifEnableGroup,
                        ciscoEnergywiseActivationGroup,
                        ciscoEnergywiseEntityGroupSup1,
                        ciscoEnergywiseEventGroupSup1,
                        cewEnergywiseNotifGroupRev1,
                        ciscoEnergywiseEntityGroupSup2,
                        ciscoEnergywiseNeighborGroupSup1
                    }

    GROUP           ciscoEnergywiseProxyGroup
    DESCRIPTION
        "This group is optional. All the Cisco EnergyWise entities
        may not be able to provide Cisco EnergyWise proxy support."

    OBJECT          cewDomainName
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewDomainSecret
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewProtocol
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewAddressType
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewAddress
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewPort
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEnable
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntKeyword
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntRoleDescription
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntName
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntEnergyLevel
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntConfiguredLevel
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntImportanceInt
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntAdminStatus
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewProxyStatus
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required, and active is the
        only status that needs to be supported."

    OBJECT          cewNeighborStatus
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required, and active is the
        only status that needs to be supported."

    OBJECT          cewEventStatus
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required, and active is the
        only status that needs to be supported."

    OBJECT          cewManagementSecret
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEndPointSecret
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."
    ::= { ciscoEnergywiseMIBCompliances 6 }

ciscoEnergywiseMIBFullComplianceRev3 MODULE-COMPLIANCE
    STATUS          deprecated
    DESCRIPTION
        "When this MIB is implemented with support for
        read-create, then such an implementation can 
        claim full compliance. Such devices can then 
        be both monitored and configured with this MIB."
    MODULE          -- this module
    MANDATORY-GROUPS {
                        ciscoEnergywiseEntityGroup,
                        ciscoEnergywiseNeighborGroup,
                        ciscoEnergywiseEventGroup,
                        ciscoEnergywiseNotifEnableGroup,
                        ciscoEnergywiseActivationGroup,
                        ciscoEnergywiseEntityGroupSup1,
                        ciscoEnergywiseEventGroupSup1,
                        cewEnergywiseNotifGroupRev1,
                        ciscoEnergywiseEntityGroupSup2,
                        ciscoEnergywiseNeighborGroupSup1,
                        ciscoEnergywiseEntityGroupSup3,
                        ciscoEnergywiseNeighborGroupSup2
                    }

    GROUP           ciscoEnergywiseProxyGroup
    DESCRIPTION
        "This group is optional. All the Cisco EnergyWise entities
        may not be able to provide Cisco EnergyWise proxy support."

    OBJECT          cewProxyStatus
    SYNTAX          RowStatus
    DESCRIPTION
        "Support for createAndWait and notInService is not required."

    OBJECT          cewNeighborStatus
    SYNTAX          RowStatus
    DESCRIPTION
        "Support for createAndWait and notInService is not required."

    OBJECT          cewEventStatus
    SYNTAX          RowStatus
    DESCRIPTION
        "Support for createAndWait and notInService is not
        required."
    ::= { ciscoEnergywiseMIBCompliances 7 }

ciscoEnergywiseMIBReadOnlyComplianceRev3 MODULE-COMPLIANCE
    STATUS          deprecated
    DESCRIPTION
        "When this MIB is implemented without support for
        read-create (i.e. in read-only mode), then such an 
        implementation can claim read-only compliance.  Such a 
        device can then be monitored but can not be configured 
        with this MIB."
    MODULE          -- this module
    MANDATORY-GROUPS {
                        ciscoEnergywiseEntityGroup,
                        ciscoEnergywiseNeighborGroup,
                        ciscoEnergywiseEventGroup,
                        ciscoEnergywiseNotifEnableGroup,
                        ciscoEnergywiseActivationGroup,
                        ciscoEnergywiseEntityGroupSup1,
                        ciscoEnergywiseEventGroupSup1,
                        cewEnergywiseNotifGroupRev1,
                        ciscoEnergywiseEntityGroupSup2,
                        ciscoEnergywiseNeighborGroupSup1,
                        ciscoEnergywiseEntityGroupSup3,
                        ciscoEnergywiseNeighborGroupSup2
                    }

    GROUP           ciscoEnergywiseProxyGroup
    DESCRIPTION
        "This group is optional. All the Cisco EnergyWise entities
        may not be able to provide Cisco EnergyWise proxy support."

    OBJECT          cewDomainName
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewDomainSecret
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewProtocol
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewAddressType
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewAddress
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewPort
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEnable
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntKeyword
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntRoleDescription
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntName
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntEnergyLevel
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntConfiguredLevel
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntImportanceInt
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntAdminStatus
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewProxyStatus
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required, and active is the
        only status that needs to be supported."

    OBJECT          cewNeighborStatus
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required, and active is the
        only status that needs to be supported."

    OBJECT          cewEventStatus
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required, and active is the
        only status that needs to be supported."

    OBJECT          cewManagementSecret
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEndPointSecret
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."
    ::= { ciscoEnergywiseMIBCompliances 8 }

ciscoEnergywiseMIBFullComplianceRev4 MODULE-COMPLIANCE
    STATUS          current
    DESCRIPTION
        "When this MIB is implemented with support for
        read-create, then such an implementation can 
        claim full compliance. Such devices can then 
        be both monitored and configured with this MIB."
    MODULE          -- this module
    MANDATORY-GROUPS {
                        ciscoEnergywiseEntityGroup,
                        ciscoEnergywiseNeighborGroup,
                        ciscoEnergywiseEventGroup,
                        ciscoEnergywiseNotifEnableGroup,
                        ciscoEnergywiseActivationGroup,
                        ciscoEnergywiseEntityGroupSup1,
                        ciscoEnergywiseEventGroupSup1,
                        cewEnergywiseNotifGroupRev1,
                        ciscoEnergywiseEntityGroupSup2,
                        ciscoEnergywiseNeighborGroupSup1,
                        ciscoEnergywiseEntityGroupSup3,
                        ciscoEnergywiseNeighborGroupSup2,
                        ciscoEnergywiseNeighborGroupSup3
                    }

    GROUP           ciscoEnergywiseProxyGroup
    DESCRIPTION
        "This group is optional. All the Cisco EnergyWise entities
        may not be able to provide Cisco EnergyWise proxy support."

    OBJECT          cewProxyStatus
    SYNTAX          RowStatus
    DESCRIPTION
        "Support for createAndWait and notInService is not required."

    OBJECT          cewNeighborStatus
    SYNTAX          RowStatus
    DESCRIPTION
        "Support for createAndWait and notInService is not required."

    OBJECT          cewEventStatus
    SYNTAX          RowStatus
    DESCRIPTION
        "Support for createAndWait and notInService is not
        required."
    ::= { ciscoEnergywiseMIBCompliances 9 }

ciscoEnergywiseMIBReadOnlyComplianceRev4 MODULE-COMPLIANCE
    STATUS          current
    DESCRIPTION
        "When this MIB is implemented without support for
        read-create (i.e. in read-only mode), then such an 
        implementation can claim read-only compliance.  Such a 
        device can then be monitored but can not be configured 
        with this MIB."
    MODULE          -- this module
    MANDATORY-GROUPS {
                        ciscoEnergywiseEntityGroup,
                        ciscoEnergywiseNeighborGroup,
                        ciscoEnergywiseEventGroup,
                        ciscoEnergywiseNotifEnableGroup,
                        ciscoEnergywiseActivationGroup,
                        ciscoEnergywiseEntityGroupSup1,
                        ciscoEnergywiseEventGroupSup1,
                        cewEnergywiseNotifGroupRev1,
                        ciscoEnergywiseEntityGroupSup2,
                        ciscoEnergywiseNeighborGroupSup1,
                        ciscoEnergywiseEntityGroupSup3,
                        ciscoEnergywiseNeighborGroupSup2,
                        ciscoEnergywiseNeighborGroupSup3
                    }

    GROUP           ciscoEnergywiseProxyGroup
    DESCRIPTION
        "This group is optional. All the Cisco EnergyWise entities
        may not be able to provide Cisco EnergyWise proxy support."

    OBJECT          cewDomainName
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewDomainSecret
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewProtocol
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewAddressType
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewAddress
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewPort
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEnable
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntKeyword
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntRoleDescription
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntName
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntEnergyLevel
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntConfiguredLevel
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntImportanceInt
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEntAdminStatus
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewProxyStatus
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required, and active is the
        only status that needs to be supported."

    OBJECT          cewNeighborStatus
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required, and active is the
        only status that needs to be supported."

    OBJECT          cewEventStatus
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required, and active is the
        only status that needs to be supported."

    OBJECT          cewManagementSecret
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."

    OBJECT          cewEndPointSecret
    MIN-ACCESS      read-only
    DESCRIPTION
        "Write access is not required."
    ::= { ciscoEnergywiseMIBCompliances 10 }

-- Units of Conformance

ciscoEnergywiseEntityGroup OBJECT-GROUP
    OBJECTS         {
                        cewMaxImportance,
                        cewMaxImportanceId,
                        cewEntNeighborIndex,
                        cewEntNannyVector,
                        cewEntKeyword,
                        cewEntName,
                        cewEntRoleDescription,
                        cewEntFullName,
                        cewEntEnergyUnits,
                        cewEntEnergyUsage,
                        cewEntEnergyLevel,
                        cewEntEnergyUsageProvisioned,
                        cewEntImportanceInt,
                        cewEntImportanceExt,
                        cewEntImportanceParentId,
                        cewEntParentId,
                        cewEntImportanceRelative,
                        cewEntAdminStatus,
                        cewEntOperStatus,
                        cewLevelMaxUsage,
                        cewLevelDeltaUsage,
                        cewLevelUnits,
                        cewDeviceId,
                        cewDeviceNeighborCount,
                        cewEntEnergyUsageCaliber,
                        cewDomainName
                    }
    STATUS          current
    DESCRIPTION
        "This group contains the collection of all the objects
        related to a Cisco EnergyWise entity."
    ::= { ciscoEnergywiseMIBGroups 1 }

ciscoEnergywiseNeighborGroup OBJECT-GROUP
    OBJECTS         {
                        cewNeighborId,
                        cewNeighborType,
                        cewNeighborHeartBeat,
                        cewNeighborStatus,
                        cewNeighborStorage
                    }
    STATUS          current
    DESCRIPTION
        "This group contains the collection of all the objects
        related to a Cisco EnergyWise neighbor."
    ::= { ciscoEnergywiseMIBGroups 2 }

ciscoEnergywiseEventGroup OBJECT-GROUP
    OBJECTS         {
                        cewEventLevel,
                        cewEventRecurrence,
                        cewEventStatus,
                        cewEventTime,
                        cewEventStorage,
                        cewEventOccuredErrorCode
                    }
    STATUS          current
    DESCRIPTION
        "This group contains the collection of all the objects
        related to a Cisco EnergyWise event."
    ::= { ciscoEnergywiseMIBGroups 3 }

ciscoEnergywiseProxyGroup OBJECT-GROUP
    OBJECTS         {
                        cewProxyAddressType,
                        cewProxyAddress,
                        cewProxyPort,
                        cewProxyClass,
                        cewProxyStorage,
                        cewProxyStatus
                    }
    STATUS          current
    DESCRIPTION
        "This group contains the collection of all the objects
        related to a Cisco EnergyWise proxy."
    ::= { ciscoEnergywiseMIBGroups 4 }

ciscoEnergywiseNotifGroup NOTIFICATION-GROUP
   NOTIFICATIONS    {
                        cewLevelChange,
                        cewNeighborAdded,
                        cewNeighborDeleted,
                        cewEventOccured
                    }
    STATUS          deprecated
    DESCRIPTION
        "This group contains the collection of all the
        notifications for a Cisco EnergyWise Entity."
    ::= { ciscoEnergywiseMIBGroups 5 }

ciscoEnergywiseNotifEnableGroup OBJECT-GROUP
    OBJECTS         {
                        cewLevelChangeNotifEnable,
                        cewNeighborAddedNotifEnable,
                        cewNeighborDeletedNotifEnable,
                        cewEventOccuredNotifEnable
                    }
    STATUS          current
    DESCRIPTION
        "This group contains the collection of all the
        notification enable objects for a Cisco EnergyWise Entity."
    ::= { ciscoEnergywiseMIBGroups 6 }

ciscoEnergywiseActivationGroup OBJECT-GROUP
    OBJECTS         {
                        cewDomainName,
                        cewDomainSecret,
                        cewProtocol,
                        cewAddressType,
                        cewAddress,
                        cewPort,
                        cewEnable
                    }
    STATUS          current
    DESCRIPTION
        "This group contains the collection of all the objects
        required to activate Cisco EnergyWise on Cisco EnergyWise
        entity."
    ::= { ciscoEnergywiseMIBGroups 7 }

ciscoEnergywiseEntityGroupSup1 OBJECT-GROUP
    OBJECTS         {
                        cewEntConfiguredLevel,
                        cewVersion,
                        cewManagementSecret,
                        cewEndPointSecret,
                        cewDeviceTotalUsage,
                        cewDeviceTotalUsageUnits
                    }
    STATUS          current
    DESCRIPTION
        "This group contains the collection of all the objects
        related to a Cisco EnergyWise entity."
    ::= { ciscoEnergywiseMIBGroups 8 }

ciscoEnergywiseEventGroupSup1 OBJECT-GROUP
    OBJECTS         { cewEventImportance }
    STATUS          current
    DESCRIPTION
        "This group contains the collection of all the objects
        related to a Cisco EnergyWise event."
    ::= { ciscoEnergywiseMIBGroups 9 }

cewEnergywiseNotifGroupRev1 NOTIFICATION-GROUP
   NOTIFICATIONS    {
                        cewLevelChange,
                        cewNeighborAdded,
                        cewNeighborDeleted,
                        cewEventOccuredRev1
                    }
    STATUS          current
    DESCRIPTION
        "This group contains the collection of all the
        notifications for a Cisco EnergyWise Entity."
    ::= { ciscoEnergywiseMIBGroups 10 }

ciscoEnergywiseEntityGroupSup2 OBJECT-GROUP
    OBJECTS         { cewDeviceType }
    STATUS          current
    DESCRIPTION
        "This group contains the collection of all the objects
        related to a Cisco EnergyWise event."
    ::= { ciscoEnergywiseMIBGroups 11 }

ciscoEnergywiseNeighborGroupSup1 OBJECT-GROUP
    OBJECTS         { cewNeighborDeviceType }
    STATUS          current
    DESCRIPTION
        "This group contains the collection of all the objects
        related to a Cisco EnergyWise neighbor."
    ::= { ciscoEnergywiseMIBGroups 12 }

ciscoEnergywiseEntityGroupSup3 OBJECT-GROUP
    OBJECTS         {
                        cewEntEnergyUsageCategory,
                        cewEntEnergyUsageDirection,
                        cewEntAllowSet,
                        cewEntActivityCheck,
                        cewAllowSet
                    }
    STATUS          current
    DESCRIPTION
        "This group contains the collection of all the objects
        related to a Cisco EnergyWise event."
    ::= { ciscoEnergywiseMIBGroups 13 }

ciscoEnergywiseNeighborGroupSup2 OBJECT-GROUP
    OBJECTS         {
                        cewNeighborKeyword,
                        cewNeighborConfiguredKeyword,
                        cewNeighborName,
                        cewNeighborConfiguredName,
                        cewNeighborRoleDescription,
                        cewNeighborConfiguredRoleDesc,
                        cewNeighborEnergyLevel,
                        cewNeighborConfiguredLevel,
                        cewNeighborImportance,
                        cewNeighborConfiguredImportance,
                        cewNeighborEnergyUnits,
                        cewNeighborEnergyUsage,
                        cewNeighborEnergyUsageCategory,
                        cewNeighborEnergyUsageDirection,
                        cewNeighborLevelMaxUsage,
                        cewNeighborLevelDeltaUsage,
                        cewNeighborLevelUnits
                    }
    STATUS          current
    DESCRIPTION
        "This group contains the collection of all the objects
        related to a Cisco EnergyWise neighbor."
    ::= { ciscoEnergywiseMIBGroups 14 }

ciscoEnergywiseNeighborGroupSup3 OBJECT-GROUP
    OBJECTS         {
                        cewNeighborMacAddress,
                        cewNeighborPhysicalEntityId,
                        cewNeighborParentPortIndex
                    }
    STATUS          current
    DESCRIPTION
        "This group contains the collection of objects related to a
        Cisco EnergyWise neighbor that are endpoints."
    ::= { ciscoEnergywiseMIBGroups 15 }

END