-- CISCO-CABLE-METERING-MIB.my:
-- Cisco Cable Metering MIB file
--   
-- March 2004, Sunethra Jawahar
--   
-- Copyright (c) 2004, 2009 by Cisco Systems Inc.
-- All rights reserved.
-- ********************************************************************
--   

-- This is the MIB module for Usage Based Metering for
-- DOCSIS-compliant Cable Modem Termination Systems (CMTS).
--   
-- Usage Based Metering is a software feature provided in the CMTS
-- so that cable operators can perform subscriber account
-- management and metering in a uniform and consistent manner.
-- It involves the implementation of Subscriber Account Management
-- Interface Specification (SAMIS) as defined by DOCSIS-OSSI
-- specification.

CISCO-CABLE-METERING-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY,
    NOTIFICATION-TYPE,
    OBJECT-TYPE,
    Unsigned32
        FROM SNMPv2-SMI
    OBJECT-GROUP,
    MODULE-COMPLIANCE,
    NOTIFICATION-GROUP
        FROM SNMPv2-CONF
    TruthValue,
    RowStatus,
    DateAndTime,
    TEXTUAL-CONVENTION
        FROM SNMPv2-TC
    InetAddress,
    InetAddressType,
    InetPortNumber
        FROM INET-ADDRESS-MIB
    SnmpAdminString
        FROM SNMP-FRAMEWORK-MIB
    InterfaceIndexOrZero
        FROM IF-MIB
    ciscoMgmt
        FROM CISCO-SMI;


ciscoCableMeteringMIB MODULE-IDENTITY
    LAST-UPDATED    "200910130000Z"
    ORGANIZATION    "Cisco Systems, Inc."
    CONTACT-INFO
            "Cisco Systems
            Customer Service

            Postal: Cisco Systems
            170 West Tasman Drive
            San Jose, CA 95134
            U.S.A.
            Phone:  +1 800 553-NETS
            E-mail: cs-ubr@cisco.com"
    DESCRIPTION
        "This is the MIB module for Usage Based Metering for the
        DOCSIS-compliant Cable Modem Termination Systems (CMTS).

        Usage Based Metering is a software feature provided in the
        CMTS so that cable operators can perform subscriber 
        account management and metering in a uniform and 
        consistent manner. 
        It involves the implementation of Subscriber Account 
        Management Interface Specification (SAMIS) as defined by 
        DOCSIS-OSSI specification. Usage-Based Metering is 
        essential in the processing of bills based on services 
        rendered to and consumed by paying subscribers. The SAMIS 
        specification focuses primarily on bandwidth centric 
        usage-based metering scenarios.
        The DOCSIS 1.1 RFI specification provides a mechanism for 
        a Cable Modem (CM) to register with its Cable Modem 
        Termination System (CMTS) and to configure itself based 
        on external Quality of Service (QoS) parameters when it 
        is powered up or reset. The principal mechanism for 
        providing enhanced QoS is to classify packets traversing 
        the RF MAC interface into a Service Flow. 
        A Service Flow is a unidirectional flow of packets that is
        provided a particular Quality of Service. 

        The mediation system can then rate the charges differently 
        for each of the Service Flow traffic counts based on 
        its Service Class. Thus, the mediation system obtains from 
        the CMTS the traffic counts for each named Service Flow 
        (identified by SFID) that a subscribers CM uses during 
        the metering data collection interval. The Usage Based 
        Metering requirement is that the CMTS must be able to 
        provide formatted Subscriber Usage 
        Metering Records for all subscribers attached to the CMTS,
        on demand to an external collection system. Optionally, 
        the metering records can be stored locally so that it is 
        available via ftp to the external collection server.

        The CMTS provides two configuration options to handle the
        export of metering data.
        Local :
        Store the record locally on the CMTS after collection. The
        metering system should then(operating at its own schedule)
        take the file out of the CMTS and is also responsible for
        deletion of the local file on the CMTS.  The deletion of 
        the file is an indication to the metering collector to 
        start construction of the new metering record which will 
        then be written to the local filesystem and the cycle 
        continues.

        Streaming: 
        Stream the records to an external collection system as
        they get generated.  The time interval in which the record
        will be generated is configurable at the CMTS. A secure 
        and reliable stream is used to transport the metering 
        record out of the CMTS. 
        In case the connection to external metering system is 
        not possible, CMTS will retry establishing channel for a 
        max specified times. 

        The MIB allows for configuration of the parameters that 
        control the metering record collection like interval, 
        amount of metering information required, location or IP 
        address of the collection server, and metering filename. 
        In addition it provides for some important notificatons to
        the NMS to indicate the success/failure of the 
        metering collection."
    REVISION        "200910130000Z"
    DESCRIPTION
        "Added a new enum type ipdr to ccmtrCollectionType."
    REVISION        "200905180000Z"
    DESCRIPTION
        "Deprecated ccmtrCollectionInterval.

        Deprecated ciscoCableMeteringCompliance and added
        ciscoCableMeteringComplianceRev1 to replace it.

        Deprecated ccmtrMeteringObjGroup.

        Added the following new objects:
        ccmtrCollectionSrcIfIndex
        ccmtrCollectionRevInterval
        ccmtrCollectionDataPerSession
        ccmtrCollectionDataTimer

        Added the following new OBJECT-GROUP:
        ccmtrMeteringObjGroupRev1
        ccmtrMeteringSrcIntfObjGroup
        ccmtrMeteringRateCtrlObjGroup"
    REVISION        "200403300000Z"
    DESCRIPTION
        "Initial version of this MIB module."
    ::= { ciscoMgmt 424 }



CcmtrStatus ::= TEXTUAL-CONVENTION
    STATUS          current
    DESCRIPTION
        "The CcmtrStatus is used to indicate success or failure status
        that occurred during the process of writing the metering 
        records to the non-volatile memory device or 
        during streaming them to an external mediation
        or collection server
        It has the following defined values:
        - 'unknown', indicates other reasons for failure of write/stream
           of the metering records . 
        - 'success', indicates that write of the metering file or 
           streaming to the collection server was successful.
        - 'deviceFull', indicates that there is not enough space on the 
           non-volatile memory device for writing the metering record
           file.
        - 'writeError', indicates that there was a write error when 
           trying to write the metering record file or stream to the 
           collection server.
        - 'fileNotExist', indicates that the metering file has not yet 
           been created for access by the collection server.   
        - 'connectionTimeout', indicates a failure to connect to the 
           collection server.
        - 'dataIncomplete', indicates that there was a failure during
           write or streaming and that the metering record might be 
           incomplete."
    SYNTAX          INTEGER  {
                        unknown(1),
                        success(2),
                        deviceFull(3),
                        writeError(4),
                        fileNotExist(5),
                        connectionTimeout(6),
                        dataIncomplete(7)
                    }

CcmtrCollectionServer ::= TEXTUAL-CONVENTION
    STATUS          current
    DESCRIPTION
        "The CcmtrCollectionServer is used to indicate the type of
        the collection server.
        It has the following defined values:
        - 'primary', indicates that the collection server is primary
           and will be the first server to which streaming will be
           attempted. 
        - 'secondary', indicates that the collection server is
           secondary and that it will be used only if streaming
           to the primary server failed."
    SYNTAX          INTEGER  {
                        primary(1),
                        secondary(2)
                    }
ciscoCableMeteringMIBNotifs  OBJECT IDENTIFIER
    ::= { ciscoCableMeteringMIB 0 }

ciscoCableMeteringMIBObjects  OBJECT IDENTIFIER
    ::= { ciscoCableMeteringMIB 1 }

ccmtrMeteringConfig  OBJECT IDENTIFIER
    ::= { ciscoCableMeteringMIBObjects 1 }

ccmtrMetering  OBJECT IDENTIFIER
    ::= { ciscoCableMeteringMIBObjects 2 }


ccmtrCollectionType OBJECT-TYPE
    SYNTAX          INTEGER  {
                        none(1),
                        local(2),
                        stream(3),
                        ipdr(4)
                    }
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "Current method of export for metering data.
        The enumerations are:
        none(1)    : Metering collection has not been enabled.
        local(2)   : Store the collected metering records locally 
                     on the CMTS. 
        stream(3)  : Stream the metering records to an external 
                     collection or mediation server.
        ipdr(4)    : Stream the metering records to an ipdr (Internet 
                     Proticol Detail Record)collector." 
    ::= { ccmtrMeteringConfig 1 }

-- This scalar object will be used if one would like to store the
-- metering records locally.

ccmtrCollectionFilesystem OBJECT-TYPE
    SYNTAX          SnmpAdminString (SIZE  (0..80))
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "The filesystem where metering records are to be stored.
        This object makes sense only if ccmtrCollectionType object 
        is local which indicates that the metering records are 
        to be stored in the local filesystem. 
        When ccmtrCollectionType is 'stream' this object will
        retain its set value though it will not be used." 
    ::= { ccmtrMeteringConfig 2 }
-- The following scalar objects and table will be used if one would
-- like to stream the metering records to an external collection
-- system.

ccmtrCollectionTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CcmtrCollectionEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "This table is used only if ccmtrCollectionType object is
        stream which indicates that the metering records are to 
        be streamed to an external collection server. 
        It contains IP address information of the  collection 
        server. In addition it contains other configurable 
        parameters like interval, retries etc needed for 
        streaming the metering records."
    ::= { ccmtrMeteringConfig 3 }

ccmtrCollectionEntry OBJECT-TYPE
    SYNTAX          CcmtrCollectionEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "A set of IP attributes of the mediation or
        collection server and configuration parameters for 
        streaming the metering records.
        An entry in this table exists for each configured
        mediation or collection server."
    INDEX           { ccmtrCollectionID } 
    ::= { ccmtrCollectionTable 1 }

CcmtrCollectionEntry ::= SEQUENCE {
        ccmtrCollectionID         CcmtrCollectionServer,
        ccmtrCollectionIpAddrType InetAddressType,
        ccmtrCollectionIpAddress  InetAddress,
        ccmtrCollectionPort       InetPortNumber,
        ccmtrCollectionRowStatus  RowStatus
}

ccmtrCollectionID OBJECT-TYPE
    SYNTAX          CcmtrCollectionServer
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "Identification of a IP address and port number
        associated with the mediation or collection server. 
        The ccmtrCollectionID is used in determining the order 
        of the IP address, port number to which the streaming will
        take place. The primary represents the first
        collection server and secondary represents the
        second collection server if streaming to the primary
        failed for any reason. Thus primary entry 
        must be created before the secondary." 
    ::= { ccmtrCollectionEntry 1 }

ccmtrCollectionIpAddrType OBJECT-TYPE
    SYNTAX          InetAddressType
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "The type of internet address of ccmtrCollectionIpAddress."
    DEFVAL          { ipv4 } 
    ::= { ccmtrCollectionEntry 2 }

ccmtrCollectionIpAddress OBJECT-TYPE
    SYNTAX          InetAddress
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "The IP address of the collection server. It will be of
        type as referred by ccmtrCollectionIpAddrType.
        The ccmtrCollectionPort should be also valid along with 
        ccmtrCollectionIpAddress for a row to be created. The 
        primary collection server IP address represented by
        ccmtrCollectionID equal to 1 must be created before the
        secondary collection server IP address." 
    ::= { ccmtrCollectionEntry 3 }

ccmtrCollectionPort OBJECT-TYPE
    SYNTAX          InetPortNumber
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "The port number of the collection server. This port number
        chosen should not be any of the well defined ports.
        The ccmtrCollectionIpAddress should be also valid along 
        with ccmtrCollectionPort for a row to be created. The 
        primary collection server port represented by
        ccmtrCollectionID equal to 1 must be created before the
        secondary collection server port." 
    ::= { ccmtrCollectionEntry 4 }

ccmtrCollectionRowStatus OBJECT-TYPE
    SYNTAX          RowStatus
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "Controls and reflects the status of rows in this table.
        It can use used for creation, modifying and deleting
        entries in this table.
        The ccmtrCollectionPort should also be valid along with 
        ccmtrCollectionIpAddress for a row to be created.
        The ccmtrCollectionID 1 represents the primary
        collection server and ccmtrCollectionID 2 represents the
        secondary collection server. Thus ccmtrCollectionID of 1
        must be created before the ccmtrCollectionID of 2." 
    ::= { ccmtrCollectionEntry 8 }
 


ccmtrCollectionInterval OBJECT-TYPE
    SYNTAX          Unsigned32 (15..1440)
    UNITS           "minutes"
    MAX-ACCESS      read-write
    STATUS          deprecated
    DESCRIPTION
        "The interval in which the metering information is
        collected. 
        This object makes sense only if ccmtrCollectionType object 
        is stream which indicates that the metering records 
        are to be streamed to an external collection server.
        This object is deprecated and replaced by
        ccmtrCollectionRevInterval. While retrieving the value of
        ccmtrCollectionInterval, the minimum value of 15 will be
        returned if the value of ccmtrCollectionRevInterval is lower
        than 15."
    DEFVAL          { 30 } 
    ::= { ccmtrMeteringConfig 4 }

ccmtrCollectionRetries OBJECT-TYPE
    SYNTAX          Unsigned32 (0..5)
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "The number of retries to stream the metering records to
        the external collection server before an error is flagged. 
        This object makes sense only if ccmtrCollectionType object 
        is stream which indicates that the metering records 
        are to be streamed to an external collection server."
    DEFVAL          { 0 } 
    ::= { ccmtrMeteringConfig 5 }

ccmtrCollectionSecure OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "An indication of whether the streaming to the collection
        server should be secure or not. The value of true
        indicates that the streaming will be secure and false
        indicates non-secure. 
        However the secure option is available only if the image 
        on the CMTS allows for security.
        This object makes sense only if ccmtrCollectionType object 
        is stream which indicates that the metering records 
        are to be streamed to an external collection server."
    DEFVAL          { false } 
    ::= { ccmtrMeteringConfig 6 }

-- The following objects are used to change the contents of metering
-- records based on requirements of the collection server.

ccmtrCollectionCpeList OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "An indication if one would like the metering records to
        contain the CPE(Customer premises equipment) IP addresses. 
        This option is provided to improve performance.
        By default, this object is true which means the CPE 
        information will always be present."
    DEFVAL          { true } 
    ::= { ccmtrMeteringConfig 7 }

ccmtrCollectionAggregate OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "An indication if one would like only aggregate Service Flow
        information per Cable Modem to be recorded. In this case 
        the record will have a SFID of 0 and a blank Service Class 
        Name. The distinction between upstream and downstream will 
        however be maintained. The counters present in the metering
        records in this case will be the aggregate. i.e., sum of all
        upstream/downstream service flows. By default, this object 
        is false which means that the metering records will 
        contain service flow counter information for all service 
        flows per CM."
    DEFVAL          { false } 
    ::= { ccmtrMeteringConfig 8 }

ccmtrCollectionSrcIfIndex OBJECT-TYPE
    SYNTAX          InterfaceIndexOrZero
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "The ifIndex of the interface which will be used as the source
        interface for the billing packets.
        When ccmtrCollectionType is 'local', the IP address of this
        source interface will be used as the CMTS IP address in the
        billing packets. When ccmtrCollectionType is 'stream', the
        source IP address of the billing packets as well as the CMTS IP
        address in billing packets will be changed to the IP address of
        this interface. In both the cases, the mac address of the source
        interface would be used in the billing packet headers.
        A value of zero on this object indicates that the source
        interface is not specifically configured and the system will
        determine the source interface to use for billing packets
        dynamically. This object can only be set when
        ccmtrCollectionType is either 'local' or 'stream'."
    DEFVAL          { 0 } 
    ::= { ccmtrMeteringConfig 9 }

ccmtrCollectionRevInterval OBJECT-TYPE
    SYNTAX          Unsigned32 (0..4294967295)
    UNITS           "minutes"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "The interval at which the metering information is
        collected. 
        This object is of significance only if ccmtrCollectionType
        object is 'stream' which indicates that the metering records 
        are to be streamed to an external collection server."
    DEFVAL          { 30 } 
    ::= { ccmtrMeteringConfig 10 }

ccmtrCollectionDataPerSession OBJECT-TYPE
    SYNTAX          Unsigned32 (3..30)
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the number of service flow data
        that would be collected at a Cable linecard in one session.
        ccmtrCollectionDataPerSession together with
        ccmtrCollectionDataTimer aims to control as well as
        throttle the rate of export of the service flow data from the
        Cable linecard to the Route Processor. This means that a Cable
        linecard would collect ccmtrCollectionDataPerSession number of
        service flow data and then pause for ccmtrCollectionDataTimer
        before resuming collection. The cable linecard to route
        processor throttling in turn affects the time to export all of
        the service flow data from the CMTS to a collection server.
        Time to export (minutes) = 
        (total flows in system * ccmtrCollectionDataTimer) /
        (ccmtrCollectionDataPerSession * 1000 * 60)
        This object cannot be modified during data export from the CMTS
        to a collection server."
    DEFVAL          { 5 } 
    ::= { ccmtrMeteringConfig 11 }

ccmtrCollectionDataTimer OBJECT-TYPE
    SYNTAX          Unsigned32 (8..500)
    UNITS           "milliseconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "This object specifies the time interval before the start of the
        next session of service flow data collection at a Cable
        linecard.
        After collection of ccmtrCollectionDataPerSession service flow
        data at a Cable linecard, the linecard would resume collection
        only after an interval of ccmtrCollectionDataTimer milliseconds.
        This object cannot be modified during data export from the CMTS
        to a collection server."
    DEFVAL          { 100 } 
    ::= { ccmtrMeteringConfig 12 }

-- The following objects are those that are required for the metering
-- success/failure notifications

ccmtrCollectionStatus OBJECT-TYPE
    SYNTAX          CcmtrStatus
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "The status of the last metering data export. It indicates
        the success or failure of writing the metering record file 
        or streaming the record to the collection server." 
    ::= { ccmtrMetering 1 }

ccmtrCollectionDestination OBJECT-TYPE
    SYNTAX          SnmpAdminString (SIZE  (1..80))
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "It represents the name of the file that is created to
        store the metering record or the IP address and port 
        number to which the metering information was streamed in 
        both the success and failure scenerios. 
        In the case of local storage it is the filename generated 
        as the CMTS host name followed by the timestamp when the 
        file was created. 
        The file will be stored in the filesystem as specified in 
        ccmtrCollectionFilesystem.
        In the case of streaming it is the IP address and port 
        number in the format IPADDRESS:PORT# to which the last 
        streaming took place." 
    ::= { ccmtrMetering 2 }

ccmtrCollectionTimestamp OBJECT-TYPE
    SYNTAX          DateAndTime
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "The time when the last metering record was exported
        successfully or with some failure." 
    ::= { ccmtrMetering 3 }

ccmtrMeteringNotifEnable OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "An indication of whether the notifications associated
        with metering are enabled or disabled. 
        true indicates the notification is enabled and 
        false indicates the notification is disabled."
    DEFVAL          { false } 
    ::= { ccmtrMetering 4 }

-- The Cisco Cable Metering MIB Notifications

ccmtrCollectionNotification NOTIFICATION-TYPE
    OBJECTS         {
                        ccmtrCollectionStatus,
                        ccmtrCollectionDestination,
                        ccmtrCollectionTimestamp
                    }
    STATUS          current
    DESCRIPTION
        "A notification that is sent to indicate the success or
        failure in creating the metering record file or streaming 
        it to the collection server.
        ccmtrCollectionStatus represents the success or 
        failure of the export. 
        ccmtrCollectionDestination and ccmtrCollectionTimestamp 
        represent the destinaton and timestamp of the export in 
        both the success and failure scenerios. 
        The receipt of this notification is 
        an indication to the collection server that the file can be
        accessed via ftp or any file transfer protocol in the case
        of local storage."
   ::= { ciscoCableMeteringMIBNotifs 1 }
ciscoCableMeteringMIBConformance  OBJECT IDENTIFIER
    ::= { ciscoCableMeteringMIB 3 }

ciscoCableMeteringMIBCompliances  OBJECT IDENTIFIER
    ::= { ciscoCableMeteringMIBConformance 1 }

ciscoCableMeteringMIBGroups  OBJECT IDENTIFIER
    ::= { ciscoCableMeteringMIBConformance 2 }


-- compliance statements

ciscoCableMeteringCompliance MODULE-COMPLIANCE
    STATUS          deprecated
    DESCRIPTION
        "The compliance statement for CMTS devices that implement
        the Usage Based Metering feature.
        This compliance is deprecated by
        ciscoCableMeteringComplianceRev1."
    MODULE          -- this module
    MANDATORY-GROUPS {
                        ccmtrMeteringObjGroup,
                        ccmtrMeteringNotifCtrlGroup,
                        ccmtrMeteringNotifGroup
                    }

    OBJECT          ccmtrCollectionIpAddrType
    DESCRIPTION
        "Only ipv4 type of internet address is supported."

    OBJECT          ccmtrCollectionPort
    DESCRIPTION
        "Value of 0 for port number is not supported."

    OBJECT          ccmtrCollectionRowStatus
    DESCRIPTION
        "createAndGo, active and destroy are the
        only RowStatus values that will be supported for this
        object."
    ::= { ciscoCableMeteringMIBCompliances 1 }

ciscoCableMeteringComplianceRev1 MODULE-COMPLIANCE
    STATUS          current
    DESCRIPTION
        "The compliance statement for CMTS devices that implement
        the Usage Based Metering feature."
    MODULE          -- this module
    MANDATORY-GROUPS {
                        ccmtrMeteringNotifCtrlGroup,
                        ccmtrMeteringNotifGroup,
                        ccmtrMeteringObjGroupRev1,
                        ccmtrMeteringSrcIntfObjGroup,
                        ccmtrMeteringRateCtrlObjGroup
                    }

    OBJECT          ccmtrCollectionIpAddrType
    DESCRIPTION
        "Only ipv4 type of internet address is supported."

    OBJECT          ccmtrCollectionPort
    DESCRIPTION
        "Value of 0 for port number is not supported."

    OBJECT          ccmtrCollectionRowStatus
    DESCRIPTION
        "createAndGo, active and destroy are the only RowStatus values
        that will be supported for this object."
    ::= { ciscoCableMeteringMIBCompliances 2 }

-- units of conformance

ccmtrMeteringObjGroup OBJECT-GROUP
    OBJECTS         {
                        ccmtrCollectionType,
                        ccmtrCollectionFilesystem,
                        ccmtrCollectionIpAddrType,
                        ccmtrCollectionIpAddress,
                        ccmtrCollectionPort,
                        ccmtrCollectionInterval,
                        ccmtrCollectionRetries,
                        ccmtrCollectionSecure,
                        ccmtrCollectionRowStatus,
                        ccmtrCollectionCpeList,
                        ccmtrCollectionAggregate,
                        ccmtrCollectionStatus,
                        ccmtrCollectionDestination,
                        ccmtrCollectionTimestamp
                    }
    STATUS          deprecated
    DESCRIPTION
        "Group of objects implemented in CMTS
        providing for usage based metering configuration
        and notification information.
        This group is deprecated by ccmtrMeteringObjGroupRev1."
    ::= { ciscoCableMeteringMIBGroups 1 }

ccmtrMeteringNotifCtrlGroup OBJECT-GROUP
    OBJECTS         { ccmtrMeteringNotifEnable }
    STATUS          current
    DESCRIPTION
        "The notification control which a
        CISCO-CABLE-METERING-MIB
        is required to implement."
    ::= { ciscoCableMeteringMIBGroups 2 }

ccmtrMeteringNotifGroup NOTIFICATION-GROUP
   NOTIFICATIONS    { ccmtrCollectionNotification }
    STATUS          current
    DESCRIPTION
        "The notification which a CISCO-CABLE-METERING-MIB
        is required to implement."
    ::= { ciscoCableMeteringMIBGroups 3 }

ccmtrMeteringObjGroupRev1 OBJECT-GROUP
    OBJECTS         {
                        ccmtrCollectionType,
                        ccmtrCollectionFilesystem,
                        ccmtrCollectionIpAddrType,
                        ccmtrCollectionIpAddress,
                        ccmtrCollectionPort,
                        ccmtrCollectionRowStatus,
                        ccmtrCollectionRetries,
                        ccmtrCollectionSecure,
                        ccmtrCollectionCpeList,
                        ccmtrCollectionAggregate,
                        ccmtrCollectionRevInterval,
                        ccmtrCollectionStatus,
                        ccmtrCollectionDestination,
                        ccmtrCollectionTimestamp
                    }
    STATUS          current
    DESCRIPTION
        "Group of objects implemented in CMTS providing for usage based
        metering configuration and notification information."
    ::= { ciscoCableMeteringMIBGroups 4 }

ccmtrMeteringSrcIntfObjGroup OBJECT-GROUP
    OBJECTS         { ccmtrCollectionSrcIfIndex }
    STATUS          current
    DESCRIPTION
        "Group of objects implemented in CMTS to define the source
        interface for the billing packets."
    ::= { ciscoCableMeteringMIBGroups 5 }

ccmtrMeteringRateCtrlObjGroup OBJECT-GROUP
    OBJECTS         {
                        ccmtrCollectionDataPerSession,
                        ccmtrCollectionDataTimer
                    }
    STATUS          current
    DESCRIPTION
        "Group of objects implemented in CMTS to control as well as
        throttle the rate of export of the service flow data."
    ::= { ciscoCableMeteringMIBGroups 6 }

END