-- This file was included in WWP MIB release 04-10-01-0027
 --
 -- WWP-LEOS-CHASSIS-MIB.my
 --
 --

 WWP-LEOS-CHASSIS-MIB DEFINITIONS ::= BEGIN

 IMPORTS 		
     Integer32, Unsigned32, Gauge32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
     	    FROM SNMPv2-SMI
     TruthValue, DateAndTime, MacAddress, DisplayString, TEXTUAL-CONVENTION
            FROM SNMPv2-TC
     wwpModulesLeos		
	    FROM WWP-SMI;	

 wwpLeosChassisMIB MODULE-IDENTITY
	    LAST-UPDATED "201209270000Z"
	    ORGANIZATION "Ciena, Inc"
	    CONTACT-INFO
		    "   Mib Meister
		  			115 North Sullivan Road
					Spokane Valley, WA 99037
		        	USA		 		
		        	Phone:  +1 509 242 9000
					Email:  support@ciena.com"
		DESCRIPTION
		    "Added wwpLeosSystemPartNumber and wwpLeosSystemSerialNumber"
		REVISION    "201209270000Z"
		DESCRIPTION
		    "Added new last reset reasons."
		REVISION    "201111140000Z"
		DESCRIPTION
			"Added wwpLeosChassisDoorAlarmTable for configuring door alarm dampening on the 3911."
		REVISION	   "201103220000Z" 
		DESCRIPTION
			"Added wwpLeosChassisExternalAlarmStatusChangeNotification."
		REVISION 	"201001270000Z"			
		DESCRIPTION
			"Added wwpLeosChassisInnerDoorStatusChangeNotification and wwpLeosChassisOuterDoorStatusChangeNotification."
		REVISION 	"200911090000Z"
		DESCRIPTION
			"Added objects to specify chassis Attributes like the deviceId, h/w version,
			param version, Inner/Outer Door status, Mfg Date, MAC address. Also added 
			notification objects for Dying Gasp and Inner/Outer Door open/close."
		REVISION     "200810060000Z"  
	        DESCRIPTION
		        "The MIB module for the WWP Specifc chassis mib. It contains the 
                         variables which applies on the whole chassis for the WWP System."
		REVISION 	"200806140000Z"
	        DESCRIPTION
		        "Added the power capabilities and FPGA AOAM fields under wwpLeosChassisPlatformCaps."
	    REVISION     "200705060048Z"  --  5th May. 2007  
	    DESCRIPTION
		    "Updated the battery status. Added the four notifications
                    for the battery state change. The new added notification
                    wwpLeosChassisPowerSourceNotification replaces the 
                    wwpLeosChassisPowerSwitchNotification."
            REVISION     "200304280000Z"  -- 28th April. 2003  
	    DESCRIPTION
		    "Added valid range check for time-offset settings using the
                    wwpLeosChassisSystemTimeOffset object. The range was previously
                    unchecked accepting the maximum 32bit signed integer values."
	    REVISION     "200303110000Z"  -- 11th March. 2003  
	    DESCRIPTION
		    "Changed the temperature thresholds to be read-write.
		    Added Battery States and updated the notification for the 
		    battery states. Added dry contact, door and RF notifications."
	    REVISION    "200104031700Z"
	    DESCRIPTION
		    "Initial creation."
	    ::= { wwpModulesLeos 11 }

 
 --
 -- Textual conventions
 --

 PortList ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "Each octet within this value specifies a set of eight
        ports, with the first octet specifying ports 1 through
        8, the second octet specifying ports 9 through 16, etc.
        Within each octet, the most significant bit represents
        the lowest numbered port, and the least significant bit
        represents the highest numbered port.  Thus, each port
        of the bridge is represented by a single bit within the
        value of this object.  If that bit has a value of '1'
        then that port is included in the set of ports; the port
        is not included if its bit has a value of '0'."
    SYNTAX      OCTET STRING (SIZE (0..255))	
     FileName ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "255a"
    STATUS       current
    DESCRIPTION
            "Represents the textual convention which defines the 
	     name string and display hint"
    SYNTAX       OCTET STRING (SIZE (0..64))					

 --
 -- Node definitions
 --
	
 wwpLeosChassisMIBObjects OBJECT IDENTIFIER ::= { wwpLeosChassisMIB 1 }
 
 wwpLeosChassis OBJECT IDENTIFIER ::= { wwpLeosChassisMIBObjects 1 }
 wwpLeosChassisNotifAttrs OBJECT IDENTIFIER ::= { wwpLeosChassisMIBObjects 2 }
 
  -- the Chassis Module 

 wwpLeosChassisModule OBJECT IDENTIFIER ::= { wwpLeosChassis 1 } 

 -- the Battery Module 

 wwpLeosChassisBatteryModule OBJECT IDENTIFIER ::= { wwpLeosChassis 2 } 

 -- the Power Supply module group.
          
 wwpLeosChassisPowerSupplyModule OBJECT IDENTIFIER ::= { wwpLeosChassis 3 }

 -- the Fan module group.
 
 wwpLeosChassisFanModule  OBJECT IDENTIFIER ::= { wwpLeosChassis 4 } 

 -- the Temp Module

 wwpLeosChassisTempSensor OBJECT IDENTIFIER ::= { wwpLeosChassis 5 }  
 
 -- The Chassis Notif Objects
 
 wwpLeosChassisNotif   OBJECT IDENTIFIER ::= { wwpLeosChassis 7 }
 
 -- The Chassis Platform Capabilities Objects
 
 wwpLeosChassisPlatformCaps   OBJECT IDENTIFIER ::= { wwpLeosChassis 8 }
 
 -- The Chassis Resource Counts Objects
 
 wwpLeosChassisResourceCounts   OBJECT IDENTIFIER ::= { wwpLeosChassis 9 }
 
 
 
 -- Notifications 
  
 wwpLeosChassisMIBNotificationPrefix  OBJECT IDENTIFIER ::= { wwpLeosChassisMIB 2 } 
 wwpLeosChassisMIBNotifications       OBJECT IDENTIFIER ::=  
                       { wwpLeosChassisMIBNotificationPrefix 0 }

 -- Conformance information 
 
 wwpLeosChassisMIBConformance OBJECT IDENTIFIER ::= { wwpLeosChassisMIB 3 } 
 wwpLeosChassisMIBCompliances OBJECT IDENTIFIER ::= { wwpLeosChassisMIBConformance 1 } 		
 wwpLeosChassisMIBGroups      OBJECT IDENTIFIER ::= { wwpLeosChassisMIBConformance 2 }
 
 wwpLeosChassisRebootState    OBJECT-TYPE
     SYNTAX           TruthValue
     MAX-ACCESS       read-write
     STATUS           current
     DESCRIPTION
	     "Setting this to true will cause chassis to reboot only if
	      software upgrade is not in progress."
     DEFVAL { false }
     ::= { wwpLeosChassisModule 1 }
 
 wwpLeosChassisSystemTimeOffsetScope    OBJECT-TYPE
     SYNTAX           INTEGER {
     					    dhcp(1),
     					    user(2),
     					    both(3)					
     					}
     MAX-ACCESS       read-only
     STATUS           current
     DESCRIPTION
	     "This object specifies who has configured system time-offset."     
     ::= { wwpLeosChassisModule 2 }
          
 wwpLeosChassisSystemTimeOffset    OBJECT-TYPE
     SYNTAX           Integer32 (-43200..50400)
     UNITS			  "seconds"
     MAX-ACCESS       read-write
     STATUS           current
     DESCRIPTION
	     "The system time-offset in seconds from 
	      UTC -- positive->east, negative->west."     
     ::= { wwpLeosChassisModule 3 }
     
 wwpLeosChassisSerialConsoleState    OBJECT-TYPE
     SYNTAX           INTEGER {
     					 disabled(1),
     					 enabled(2)
     				  }     
     MAX-ACCESS       read-write
     STATUS           current
     DESCRIPTION
	     "This object specifies the current state of serial console. 
	      It can be set to disabled/enabled."     
     ::= { wwpLeosChassisModule 4 }
     
 wwpLeosChassisShellInactivityTimerState    OBJECT-TYPE
     SYNTAX           INTEGER {
     					disabled(1),
     					enabled(2)
     				  }
     MAX-ACCESS       read-write
     STATUS           current
     DESCRIPTION
	     "This object specifies if device should close the shell sessions which
	      are inactive for sometime. The time is decided by 
	      wwpLeosChassisShellInactivityTimeout."	      
     ::= { wwpLeosChassisModule 5 }
     
 wwpLeosChassisShellInactivityTimeout    OBJECT-TYPE
     SYNTAX           INTEGER (1..1500)
     UNITS			  "minutes"
     MAX-ACCESS       read-write
     STATUS           current
     DESCRIPTION
	     "This object specifies the idle time after which the device will 
	      forcefully close the shell sessions if enabled 
	      (decided by wwpLeosChassisShellInactivityTimerState)."     
     ::= { wwpLeosChassisModule 6 }  
          
 -- Defect 17574: Fixed by removing baud rate settings
 -- wwpLeosChassisSerialConsoleBaudRate  OBJECT-TYPE
 --    SYNTAX        INTEGER {
 --    					rate9600(1),
 --    					rate19200(2),
 --    					rate38400(3),
 --    					rate57600(4),
 --    					rate15200(5)    					
 --    				}
 --    MAX-ACCESS    read-write
 --    STATUS        current
 --    DESCRIPTION
 --        "The baud rate to be used for the serial console."
 --    ::= { wwpLeosChassisModule 7 }
 
 wwpLeosChassisSerialConsoleDataBits  OBJECT-TYPE
    SYNTAX        INTEGER (7..8)
    MAX-ACCESS    read-write
    STATUS        current
    DESCRIPTION
        "The data bits to be used for the serial console."
    ::= { wwpLeosChassisModule 8 }

-- Defect 17942 
-- wwpLeosChassisSerialConsoleFlowCarrierDetect  OBJECT-TYPE
--    SYNTAX        INTEGER {
--    					off(1),
--    					on(2)
--    				}
--    MAX-ACCESS    read-write
--    STATUS        current
--    DESCRIPTION
--        "This mib object specifies if the flow carrier detection should be 'on' or 'off' for the serial console."
--    ::= { wwpLeosChassisModule 9 }
 
-- Defect 17942 
-- wwpLeosChassisSerialConsoleFlowRTSCTS  OBJECT-TYPE
--    SYNTAX        INTEGER {
--    					off(1),
--    					on(2)
--    				}
--    MAX-ACCESS    read-write
--    STATUS        current
--    DESCRIPTION
--        "This mib object specifies if the flow RTS CTS should be 'on' or 'off' for the serial console."
--    ::= { wwpLeosChassisModule 10 }
 
-- Defect 17942 
-- wwpLeosChassisSerialConsoleFlowDSRDTR  OBJECT-TYPE
--    SYNTAX        INTEGER {
--    					off(1),
--    					on(2)
--    				}
--    MAX-ACCESS    read-write
--    STATUS        current
--    DESCRIPTION
--        "This mib object specifies if the flow DSR DTR should be 'on' or 'off' for the serial console."
--    ::= { wwpLeosChassisModule 11 }
 
 wwpLeosChassisSerialConsoleParity  OBJECT-TYPE
    SYNTAX        INTEGER {
    					even(1),
    					mark(2),
    					none(3),
    					odd(4),
    					space(5)
    				}
    MAX-ACCESS    read-write
    STATUS        current
    DESCRIPTION
        "The parity to be used for the serial console."
    ::= { wwpLeosChassisModule 12 }
 
 wwpLeosChassisSerialConsoleStopBits  OBJECT-TYPE
    SYNTAX        INTEGER (1..2)
    MAX-ACCESS    read-write
    STATUS        current
    DESCRIPTION
        "The stop bits to be used for the serial console."
    ::= { wwpLeosChassisModule 13 }
    
 wwpLeosChassisRebootNow    OBJECT-TYPE
     SYNTAX           TruthValue
     MAX-ACCESS       read-write
     STATUS           current
     DESCRIPTION
	     "Setting this to true will force the device to reboot irrespective of whether software upgrade 
	      is in progress or not."
     DEFVAL { false }
     ::= { wwpLeosChassisModule 14 }   
     
 wwpLeosChassisShellLoginTimerState    OBJECT-TYPE
     SYNTAX           INTEGER {
     					disabled(1),
     					enabled(2)
     				  }
     MAX-ACCESS       read-write
     STATUS           current
     DESCRIPTION
	     "This object specifies if device should terminate a login session which
	      is inactive for sometime. The time is decided by 
	      wwpLeosChassisShellLoginTimeout."	      
     ::= { wwpLeosChassisModule 15 }
     
 wwpLeosChassisShellLoginTimeout    OBJECT-TYPE
     SYNTAX           INTEGER (10..300)
     UNITS			  "seconds"
     MAX-ACCESS       read-write
     STATUS           current
     DESCRIPTION
	     "This object specifies the idle time after which the device will 
	      forcefully close the login session if enabled 
	      by wwpLeosChassisShellLoginTimerState."     
     ::= { wwpLeosChassisModule 16 }  
         
 wwpLeosChassisScheduledRebootTable    OBJECT-TYPE
     SYNTAX           SEQUENCE OF WwpLeosChassisScheduledRebootEntry
     MAX-ACCESS       not-accessible
     STATUS           current
     DESCRIPTION
	     "Schedule a system reboot for this box."
     ::= { wwpLeosChassisModule 17 }
     
 wwpLeosChassisWelcomeBanner OBJECT-TYPE
     SYNTAX             FileName
     MAX-ACCESS         read-write
     STATUS             current
     DESCRIPTION
                "Gets or sets the name of the current welcome banner file used
		 after the CLI Login."
     ::= { wwpLeosChassisModule 18 }

  wwpLeosChassisResetWelcomeBanner OBJECT-TYPE
     SYNTAX             TruthValue
     MAX-ACCESS         read-write
     STATUS             current
     DESCRIPTION
                "Resets the welcome banner to the default if set."
     ::= { wwpLeosChassisModule 19 }   

  wwpLeosChassisLoginBanner OBJECT-TYPE
       SYNTAX             FileName
       MAX-ACCESS         read-write
       STATUS             current
       DESCRIPTION
                "Gets or sets the name of the current login banner file used
		 before the CLI Login."
       ::= { wwpLeosChassisModule 20 }

  wwpLeosChassisResetLoginBanner OBJECT-TYPE
       SYNTAX             TruthValue
       MAX-ACCESS         read-write
       STATUS             current
       DESCRIPTION
                "Resets the login banner to the default if set."
       ::= { wwpLeosChassisModule 21 }

 wwpLeosChassisMacAddress    OBJECT-TYPE
     SYNTAX           MacAddress
     MAX-ACCESS       read-only
     STATUS           current
     DESCRIPTION
	     "This object indicates the chassis MAC address."     
     ::= { wwpLeosChassisModule 50 }
     
     wwpLeosChassisDeviceId    OBJECT-TYPE
     SYNTAX           DisplayString
     MAX-ACCESS       read-only
     STATUS           current
     DESCRIPTION
	     "This object indicates the device ID of the chassis."     
     ::= { wwpLeosChassisModule 51 }

      wwpLeosChassisSerialNumber    OBJECT-TYPE
     SYNTAX           DisplayString
     MAX-ACCESS       read-only
     STATUS           current
     DESCRIPTION
	     "This object indicates the chassis serial number."     
     ::= { wwpLeosChassisModule 52 }
     
  wwpLeosChassisMfgDate    OBJECT-TYPE
     SYNTAX           DateAndTime
     MAX-ACCESS       read-only
     STATUS           current
     DESCRIPTION
	     "This object indicates the chassis manufacturing date."     
     ::= { wwpLeosChassisModule 53 }   
   
  wwpLeosChassisParamVersion    OBJECT-TYPE
     SYNTAX           DisplayString
     MAX-ACCESS       read-only
     STATUS           current
     DESCRIPTION
	     "This object indicates the chassis param version."     
     ::= { wwpLeosChassisModule 54 }  
  
  wwpLeosChassisHardwareVersion    OBJECT-TYPE
     SYNTAX           DisplayString
     MAX-ACCESS       read-only
     STATUS           current
     DESCRIPTION
	     "This object indicates the chassis Hardware version."     
     ::= { wwpLeosChassisModule 55 }      
     
   wwpLeosChassisInnerDoorStatus	OBJECT-TYPE
   	SYNTAX       INTEGER  { 
   				  none(0),
                  open(1),
                  closed(2),
                  override(3)
              }
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
             "Specifies the status of the Inner Door."
     ::= { wwpLeosChassisModule 56 }
   
   wwpLeosChassisOuterDoorStatus	OBJECT-TYPE
   	SYNTAX       INTEGER  { 
   				  none(0),
                  open(1),
                  closed(2)                  
              }
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
             "Specifies the status of the Outer Door."
     ::= { wwpLeosChassisModule 57 }
     
   wwpLeosChassisPostState			OBJECT-TYPE
    SYNTAX		 INTEGER  {
    				enabled(1),
    				disabled(2)
    		  }
    MAX-ACCESS	  read-write
    STATUS		  current
    DESCRIPTION
    		"Specifies the POST state of the chassis."
    ::= { wwpLeosChassisModule 60	}
 
 wwpLeosChassisPostResultTable    OBJECT-TYPE
     SYNTAX           SEQUENCE OF WwpLeosChassisPostResultEntry
     MAX-ACCESS       not-accessible
     STATUS           current
     DESCRIPTION
	     "Display the Post Results only when the Chassis Post State is enabled."
     ::= { wwpLeosChassisModule 61 }
 wwpLeosChassisExternalAlarmStatus	OBJECT-TYPE
   	SYNTAX       INTEGER  { 
   				  raised(1),
                  cleared(2)                  
              }
     MAX-ACCESS  accessible-for-notify
     STATUS      current
     DESCRIPTION
             "This OID is sent in the wwpLeosChassisExternalAlarmStatusChangeNotification trap to identify whether a specific external alarm has been raised or cleared."
     ::= { wwpLeosChassisModule 62 }
                                    
 wwpLeosChassisExternalAlarm	OBJECT-TYPE
     SYNTAX       INTEGER (0..2147483647)	
     MAX-ACCESS  accessible-for-notify
     STATUS      current
     DESCRIPTION
             "This OID is sent in the wwpLeosChassisExternalAlarmStatusChangeNotification trap to identify which alarm was triggered."
     ::= { wwpLeosChassisModule 63 }    
     
  wwpLeosSystemPartNumber    OBJECT-TYPE
     SYNTAX           DisplayString
     MAX-ACCESS       read-only
     STATUS           current
     DESCRIPTION
	     "This object indicates the system part/revision number."     
     ::= { wwpLeosChassisModule 66 }      
                                
  wwpLeosSystemSerialNumber    OBJECT-TYPE
     SYNTAX           DisplayString
     MAX-ACCESS       read-only
     STATUS           current
     DESCRIPTION
	     "This object indicates the system serial number."     
     ::= { wwpLeosChassisModule 67 }      
                                

 wwpLeosChassisPostResultEntry	   OBJECT-TYPE
     SYNTAX			WwpLeosChassisPostResultEntry
     MAX-ACCESS     not-accessible
     STATUS         current
     DESCRIPTION
             "."
     INDEX  { wwpLeosChassisPostResultIndex }
     ::= { wwpLeosChassisPostResultTable 1 }
     
 WwpLeosChassisPostResultEntry  ::=   SEQUENCE	{
     wwpLeosChassisPostResultIndex		INTEGER,
     wwpLeosChassisPostResultCode		Unsigned32,
     wwpLeosChassisPostResultMessage	DisplayString
 }          
 
 wwpLeosChassisPostResultIndex OBJECT-TYPE
     SYNTAX      INTEGER  (1..32)
     MAX-ACCESS  not-accessible
     STATUS      current
     DESCRIPTION
            "Unique index for the Post Result Table."
     ::= { wwpLeosChassisPostResultEntry 1 }

 wwpLeosChassisPostResultCode OBJECT-TYPE
     SYNTAX      Unsigned32
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
	     "The result code returned by the device POST test."
     ::= { wwpLeosChassisPostResultEntry 2 }	

 wwpLeosChassisPostResultMessage OBJECT-TYPE
     SYNTAX       DisplayString
     MAX-ACCESS   read-only
     STATUS       current
     DESCRIPTION
	     "The test result string generated by the POST tests"
     ::= { wwpLeosChassisPostResultEntry 3 }

 wwpLeosChassisScheduledRebootEntry     OBJECT-TYPE
     SYNTAX         WwpLeosChassisScheduledRebootEntry
     MAX-ACCESS     not-accessible
     STATUS         current
     DESCRIPTION
             "An entry in the ScheduledRebootTable holding the date/time."
     INDEX  { wwpLeosChassisScheduledRebootIndex }
     ::= { wwpLeosChassisScheduledRebootTable 1 }

 WwpLeosChassisScheduledRebootEntry ::=  SEQUENCE  {
     wwpLeosChassisScheduledRebootIndex        INTEGER,
     wwpLeosChassisScheduledRebootTimestamp    DateAndTime,
     wwpLeosChassisScheduledRebootActive       TruthValue,
     wwpLeosChassisScheduledRebootNopost       TruthValue,
     wwpLeosChassisScheduledRebootDelay        INTEGER
 }

 wwpLeosChassisScheduledRebootIndex  OBJECT-TYPE
     SYNTAX            INTEGER (1..1)
     MAX-ACCESS        read-write
     STATUS            current
     DESCRIPTION
             "Denotes singleton table entry."
     ::= { wwpLeosChassisScheduledRebootEntry 1 }

 wwpLeosChassisScheduledRebootTimestamp    OBJECT-TYPE
     SYNTAX           DateAndTime
     MAX-ACCESS       read-write
     STATUS           current
     DESCRIPTION
	     "The date and time of the reboot scheduled for this box."  
      ::= { wwpLeosChassisScheduledRebootEntry 2 }

 wwpLeosChassisScheduledRebootActive    OBJECT-TYPE
     SYNTAX           TruthValue
     MAX-ACCESS       read-write
     STATUS           current
     DESCRIPTION
	     "Indicates whether a scheduled reboot is desired or exists."
     DEFVAL { false }
     ::= { wwpLeosChassisScheduledRebootEntry 3 }   
     
 wwpLeosChassisScheduledRebootNopost    OBJECT-TYPE
     SYNTAX           TruthValue
     MAX-ACCESS       read-write
     STATUS           current
     DESCRIPTION
	     "Indicates whether POST is disabled for next reboot."
     DEFVAL { false }
     ::= { wwpLeosChassisScheduledRebootEntry 4 }   
     
 wwpLeosChassisScheduledRebootDelay  OBJECT-TYPE
     SYNTAX            INTEGER (1..86400)
     MAX-ACCESS        read-write
     STATUS            current
     DESCRIPTION
             "Denotes seconds to wait before reboot."
     ::= { wwpLeosChassisScheduledRebootEntry 5 }

 wwpLeosChassisDoorAlarmTable    OBJECT-TYPE
     SYNTAX           SEQUENCE OF WwpLeosChassisDoorAlarmEntry
     MAX-ACCESS       not-accessible
     STATUS           current
     DESCRIPTION
	     "Door alarm settings."
     ::= { wwpLeosChassisModule 64 } 
    
 wwpLeosChassisDoorAlarmEntry     OBJECT-TYPE
     SYNTAX         WwpLeosChassisDoorAlarmEntry
     MAX-ACCESS     not-accessible
     STATUS         current
     DESCRIPTION
             "An entry in the DoorAlarmTable containing door alarm flap settings."
     INDEX  { wwpLeosChassisDoorAlarmIndex }
     ::= { wwpLeosChassisDoorAlarmTable 1 }

 WwpLeosChassisDoorAlarmEntry ::=  SEQUENCE  {
     wwpLeosChassisDoorAlarmIndex            INTEGER,
     wwpLeosChassisDoorAlarmStatus           INTEGER,
     wwpLeosChassisDoorAlarmAdminStatus      INTEGER,
     wwpLeosChassisDoorAlarmFlapDetect       INTEGER,
     wwpLeosChassisDoorAlarmFlapCount        INTEGER,
     wwpLeosChassisDoorAlarmFlapDetectTime   INTEGER,
     wwpLeosChassisDoorAlarmFlapHoldTime     INTEGER
 }

 wwpLeosChassisDoorAlarmIndex     OBJECT-TYPE
     SYNTAX         INTEGER {
                inner(0),
                outer(1)
     }
     MAX-ACCESS     accessible-for-notify
     STATUS         current
     DESCRIPTION
             "An index into the DoorAlarmTable."
     ::= { wwpLeosChassisDoorAlarmEntry 1 }

 wwpLeosChassisDoorAlarmStatus     OBJECT-TYPE
     SYNTAX         INTEGER {
                enabled(1),
                disabled(2)
     }
     MAX-ACCESS     read-only
     STATUS         current
     DESCRIPTION
             "Indicates if the door alarm is enabled or disabled."
     ::= { wwpLeosChassisDoorAlarmEntry 2 }

 wwpLeosChassisDoorAlarmAdminStatus     OBJECT-TYPE
     SYNTAX         INTEGER {
                enabled(1),
                disabled(2)
     }
     MAX-ACCESS     read-write
     STATUS         current
     DESCRIPTION
             "Indicates if the door alarm admin is set to enabled or disabled."
     DEFVAL { 1 }
     ::= { wwpLeosChassisDoorAlarmEntry 3 }

 wwpLeosChassisDoorAlarmFlapDetect     OBJECT-TYPE
     SYNTAX         INTEGER {
                enabled(1),
                disabled(2)
     }
     MAX-ACCESS     read-write
     STATUS         current
     DESCRIPTION
             "Indicates if the door alarm flap detection is either enabled or disabled."
     DEFVAL { 2 }
     ::= { wwpLeosChassisDoorAlarmEntry 4 }

 wwpLeosChassisDoorAlarmFlapCount     OBJECT-TYPE
     SYNTAX         INTEGER (3..100)
     MAX-ACCESS     read-write
     STATUS         current
     DESCRIPTION
             "The number of events that must occur during the door flap detect time for door monitoring to be disabled."
     DEFVAL { 5 }
     ::= { wwpLeosChassisDoorAlarmEntry 5 }

 wwpLeosChassisDoorAlarmFlapDetectTime     OBJECT-TYPE
     SYNTAX         INTEGER (5..3600)
     UNITS          "seconds"
     MAX-ACCESS     read-write
     STATUS         current
     DESCRIPTION
             "The amount of time in seconds during which the door flap count must be reached for door monitoring to be disabled."
     DEFVAL { 10 }
     ::= { wwpLeosChassisDoorAlarmEntry 6 }

 wwpLeosChassisDoorAlarmFlapHoldTime     OBJECT-TYPE
     SYNTAX         INTEGER (60..3600)
     UNITS          "seconds"
     MAX-ACCESS     read-write
     STATUS         current
     DESCRIPTION
             "The amount of time in seconds required to elapse before door alarm monitoring will be re-enabled."
     DEFVAL { 300 }
     ::= { wwpLeosChassisDoorAlarmEntry 7 }    
    
 -- 
 -- Power Module
 --      
 wwpLeosChassisPowerTable  OBJECT-TYPE
     SYNTAX      SEQUENCE OF WwpLeosChassisPowerEntry
     MAX-ACCESS  not-accessible
     STATUS      current
     DESCRIPTION
             "A list of power supply entries."
     ::= { wwpLeosChassisPowerSupplyModule 1 }

 wwpLeosChassisPowerEntry     OBJECT-TYPE
     SYNTAX         WwpLeosChassisPowerEntry
     MAX-ACCESS     not-accessible
     STATUS         current
     DESCRIPTION
             "An entry in the powerTable providing objects for a
             power supply."
     INDEX  { wwpLeosChassisPowerSupplyNum }
     ::= { wwpLeosChassisPowerTable 1 }

 WwpLeosChassisPowerEntry ::=  SEQUENCE  {
     wwpLeosChassisPowerSupplyNum         Integer32,
     wwpLeosChassisPowerSupplyState       INTEGER,
     wwpLeosChassisPowerSupplyType		INTEGER,
     wwpLeosChassisPowerSupplyRedundantState  INTEGER 
 }

 wwpLeosChassisPowerSupplyNum  OBJECT-TYPE
     SYNTAX            Integer32(1..2147483647) 
     MAX-ACCESS        read-only
     STATUS            current
     DESCRIPTION
             "Denotes the power supply."
     ::= { wwpLeosChassisPowerEntry 1 }

 wwpLeosChassisPowerSupplyState  OBJECT-TYPE
     SYNTAX  INTEGER  {
                  online(1),
                  offline(2),
                  faulted(3)                  
              }
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
             "Specifies the power supply's state."
     ::= { wwpLeosChassisPowerEntry 2 }

 wwpLeosChassisPowerSupplyType  OBJECT-TYPE
     SYNTAX       INTEGER  {
                       ac(1),
                       dc(2),
                       unequipped(3)                       
                  }
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
              "Specifies the power supply type."
      ::= { wwpLeosChassisPowerEntry 3 }

 wwpLeosChassisPowerSupplyRedundantState  OBJECT-TYPE
     SYNTAX  INTEGER  {
                  protected(1),
                  unprotected(2)                  
             }
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
             "Specfiies power supply redundant state."
     ::= { wwpLeosChassisPowerEntry 4 }

 wwpLeosChassisRedPowerSupplyNotifEnabled OBJECT-TYPE
     SYNTAX      TruthValue
     MAX-ACCESS  read-write
     STATUS      current
     DESCRIPTION
             "This variable  indicates  whether  the  system
             generates the wwpLeosChassisRedPowerSupplyNotification. 
             A false value prevents this notifications
             from being generated by this system."
    DEFVAL { true }
    ::= { wwpLeosChassisPowerSupplyModule 2 }

 --
 --  The Fan module group
 --
 wwpLeosChassisFanModuleTable  OBJECT-TYPE
     SYNTAX      SEQUENCE OF WwpLeosChassisFanModuleEntry
     MAX-ACCESS  not-accessible
     STATUS      current
     DESCRIPTION
             "A list of fan module entries."
     ::= { wwpLeosChassisFanModule 1 }

 wwpLeosChassisFanModuleEntry  OBJECT-TYPE
     SYNTAX         WwpLeosChassisFanModuleEntry
     MAX-ACCESS     not-accessible
     STATUS         current
     DESCRIPTION
             "An entry in the fan module Table providing objects for a
             fan module."
     INDEX  { wwpLeosChassisFanModuleNum }
     ::= { wwpLeosChassisFanModuleTable 1 }

 WwpLeosChassisFanModuleEntry ::=  SEQUENCE  {
     wwpLeosChassisFanModuleNum          Integer32,
     wwpLeosChassisFanModuleType         INTEGER,
     wwpLeosChassisFanModuleStatus       INTEGER,
     wwpLeosChassisFanAvgSpeed           Integer32,
     wwpLeosChassisFanCurrentSpeed       Integer32,
     wwpLeosChassisFanMinSpeed           Integer32
 }

 wwpLeosChassisFanModuleNum  OBJECT-TYPE
     SYNTAX        Integer32 (1..2147483647)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "Denotes the Fan module."
     ::= { wwpLeosChassisFanModuleEntry 1 }

 wwpLeosChassisFanModuleType OBJECT-TYPE
     SYNTAX        INTEGER  {
                        fixed(1),
                        hotSwappable(2),
                        unequipped(3)                        
                   }
     MAX-ACCESS    read-only
     STATUS        current
     DESCRIPTION
             "Denotes the fan modules type.
	      'fixed' means fan is fixed and cannot be removed.
	      'hotswappable' means fan can be removed and inserted 
	      whenever required.
	      'unequipped' means fan is not installed."
     ::= { wwpLeosChassisFanModuleEntry 2 }
 
 wwpLeosChassisFanModuleStatus OBJECT-TYPE
     SYNTAX        INTEGER  {
                        ok(1),
                        pending(2),
                        failure(3)                        
                   }
     MAX-ACCESS    read-only
     STATUS        current
     DESCRIPTION
             "Denotes the fan modules status. 
	      'ok' means fan is operational,
	      'pending' means fan is installed but statistics
	      are not yet available,
	      'failure' means fan is not working."
     ::= { wwpLeosChassisFanModuleEntry 3 }

 wwpLeosChassisFanAvgSpeed OBJECT-TYPE
     SYNTAX        Integer32 (0..2147483647)
     UNITS         "rpm"
     MAX-ACCESS    read-only
     STATUS        current
     DESCRIPTION
             "The fans average speed in RPM.  The average is calculated
	     on a continuous basis from system startup."
     ::= { wwpLeosChassisFanModuleEntry 4 }

 wwpLeosChassisFanCurrentSpeed OBJECT-TYPE
     SYNTAX        Integer32 (0..2147483647)
     UNITS         "rpm"
     MAX-ACCESS    read-only
     STATUS        current
     DESCRIPTION
    	     "The current speed of the fan in RPM."
     ::= { wwpLeosChassisFanModuleEntry 5 }

 wwpLeosChassisFanMinSpeed OBJECT-TYPE
     SYNTAX        Integer32 (0..2147483647)
     UNITS         "rpm"
     MAX-ACCESS    read-only
     STATUS        current
     DESCRIPTION
    	     "The minimum speed of the fan in RPM."
     ::= { wwpLeosChassisFanModuleEntry 6 }
 
 
 wwpLeosChassisFanModuleNotifEnabled OBJECT-TYPE
     SYNTAX      TruthValue
     MAX-ACCESS  read-write
     STATUS      current
     DESCRIPTION
             "This variable  indicates  whether  the  system
             generates the wwpLeosChassisFanModuleNotification. 
             A false value prevents this notifications
             from being generated by this system."
    DEFVAL { true }
    ::= { wwpLeosChassisFanModule 2 }

 --
 --  The Temp module group
 --
 wwpLeosChassisTempSensorTable  OBJECT-TYPE
     SYNTAX      SEQUENCE OF WwpLeosChassisTempSensorEntry
     MAX-ACCESS  not-accessible
     STATUS      current
     DESCRIPTION
             "A list of Temp Sensors entries."
     ::= { wwpLeosChassisTempSensor 1 }

 wwpLeosChassisTempSensorEntry  OBJECT-TYPE
     SYNTAX         WwpLeosChassisTempSensorEntry
     MAX-ACCESS     not-accessible
     STATUS         current
     DESCRIPTION
             "An entry in the Temp Sensor Table providing objects for a
             Temp Sensor."
     INDEX  { wwpLeosChassisTempSensorNum }
     ::= { wwpLeosChassisTempSensorTable 1 }

 WwpLeosChassisTempSensorEntry ::=  SEQUENCE  {
     wwpLeosChassisTempSensorNum               Integer32,
     wwpLeosChassisTempSensorValue             Integer32,
     wwpLeosChassisTempSensorHighThreshold     Integer32,
     wwpLeosChassisTempSensorLowThreshold      Integer32,
     wwpLeosChassisTempSensorState             INTEGER
 }

 wwpLeosChassisTempSensorNum  OBJECT-TYPE
     SYNTAX        Integer32 (1..2147483647)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "Denotes the Temp sensor module."
     ::= { wwpLeosChassisTempSensorEntry 1 }

 wwpLeosChassisTempSensorValue OBJECT-TYPE
     SYNTAX        Integer32
     UNITS         "degrees Celsius"
     MAX-ACCESS    read-only
     STATUS        current
     DESCRIPTION
    	     "The value of temperature measured by the sensor 
              inside the device in degrees C."
     ::= { wwpLeosChassisTempSensorEntry 2 }
 
 wwpLeosChassisTempSensorHighThreshold   OBJECT-TYPE
     SYNTAX       Integer32
     UNITS        "degrees Celsius"
     MAX-ACCESS   read-write
     STATUS       current
     DESCRIPTION
	     "The highest value that the object wwpLeosChassisTempSensorValue
              may obtain at which a wwpLeosChassisMIBTempNotification is sent."
     ::= { wwpLeosChassisTempSensorEntry 3 }

 wwpLeosChassisTempSensorLowThreshold   OBJECT-TYPE
     SYNTAX       Integer32
     UNITS        "degrees Celsius"
     MAX-ACCESS   read-write
     STATUS       current
     DESCRIPTION
	     "The Lowest value that the object wwpLeosChassisTempSensorValue
              may obtain at which a wwpLeosChassisMIBTempNotification is sent."
     ::= { wwpLeosChassisTempSensorEntry 4 }

 wwpLeosChassisTempSensorState   OBJECT-TYPE
     SYNTAX       INTEGER {
                        higherThanThreshold(0),
                        normal(1),
                        lowerThanThreshold(2)
                  }
     MAX-ACCESS   read-only
     STATUS       current
     DESCRIPTION
	     "The state indicates whether the current temp is greater than,
             equal to or less than the threshold state."
     ::= { wwpLeosChassisTempSensorEntry 5 }

 wwpLeosChassisTempNotifEnabled OBJECT-TYPE
     SYNTAX      TruthValue
     MAX-ACCESS  read-write
     STATUS      current
     DESCRIPTION
             "This variable  indicates  whether  the  system
             generates the wwpLeosChassisTempNotification. 
             A false value prevents this notifications
             from being generated by this system."
    DEFVAL { true }
    ::= { wwpLeosChassisTempSensor 2 }
 
 wwpLeosChassisTempHighThreshold OBJECT-TYPE
     SYNTAX      Integer32
     MAX-ACCESS  read-write
     STATUS      current
     DESCRIPTION
             "This variable indicates the high temperature threshold
	      to be used by the device when checking temperature 
	      of the device. This object is similar to wwpLeosChassisTempSensorHighThreshold
	      only difference is that wwpLeosChassisTempHighThreshold is 
	      global attribute not per sensor based.
	      wwpLeosChassisTempSensorHighThreshold will have the same value as 
	      wwpLeosChassisTempHighThreshold at all times. 
	      wwpLeosChassisTempSensorHighThreshold is basically redundant."
    ::= { wwpLeosChassisTempSensor 3 }

  wwpLeosChassisTempLowThreshold OBJECT-TYPE
     SYNTAX      Integer32
     MAX-ACCESS  read-write
     STATUS      current
     DESCRIPTION
             "This variable indicates the low temperature threshold
	      to be used by the device when checking temperature 
	      of the device. This object is similar to 
	      wwpLeosChassisTempSensorLowThreshold
	      only difference is that wwpLeosChassisTempLowThreshold is global 
	      attribute not per sensor based.
	      wwpLeosChassisTempSensorLowThreshold will have the same value as 
	      wwpLeosChassisTempLowThreshold at all times.
	      wwpLeosChassisTempSensorLowThreshold is basically redundant."
    ::= { wwpLeosChassisTempSensor 4 }  

 --
 -- notif group
 --  
 wwpPowerSwitchingOp OBJECT-TYPE
     SYNTAX         INTEGER {
                        none(0),
                        acToBattery(1),
                        bateryToAC(2)                     
                    }
     --MAX-ACCESS     accessible-for-notify
     MAX-ACCESS     read-only
     STATUS         current
     DESCRIPTION
             "The object to notify whether the input power supply is switching
             from ac to Battery or vice versa."
     ::= { wwpLeosChassisNotif 1 }

 --
 -- chassis battery group
 --
 wwpLeosChassisBatteryStatus     OBJECT-TYPE
     SYNTAX           INTEGER {
     					   online(0),
                           present(1),
	                   missing(2)
	              } 
     MAX-ACCESS       read-only
     STATUS           current
     DESCRIPTION
	     "Describes the current status of the 
             battery. If battery is connected then the
             status is indicated as 'present'." 
     ::= { wwpLeosChassisBatteryModule 1 }
  
 wwpLeosChassisBatteryVoltageLevel     OBJECT-TYPE
     SYNTAX           INTEGER {
     					   unknown(0),
                           normal(1),
	                   low(2)
	              } 
     MAX-ACCESS       read-only
     STATUS           current
     DESCRIPTION
	     "Describes the current voltage level of the 
             battery." 
     ::= { wwpLeosChassisBatteryModule 2 }
     
 wwpLeosChassisBatteryCondition  OBJECT-TYPE
     SYNTAX           INTEGER {
     					   unknown(0),
                           good(1),
	                   bad(2)
	              } 
     MAX-ACCESS       read-only
     STATUS           current
     DESCRIPTION
	     "Describes the current condition of the battery." 
     ::= { wwpLeosChassisBatteryModule 3 }
     
 wwpLeosChassisPowerSource OBJECT-TYPE
     SYNTAX           INTEGER {
                           primaryPower(1),
	                   battery(2)
	              } 
     MAX-ACCESS       read-only
     STATUS           current
     DESCRIPTION
	     "Describes the current power source for the device." 
     ::= { wwpLeosChassisBatteryModule 4 }
     
 wwpLeosChassisBatteryNormalStateName     OBJECT-TYPE
     SYNTAX           OCTET STRING (SIZE(1..128))  
     MAX-ACCESS       read-write
     STATUS           current
     DESCRIPTION
	     "The state name associated with the normal state
	     of the battery."
     ::= { wwpLeosChassisBatteryModule 5 }
     
 wwpLeosChassisBatteryLowStateName     OBJECT-TYPE
     SYNTAX           OCTET STRING (SIZE(1..128))  
     MAX-ACCESS       read-write
     STATUS           current
     DESCRIPTION
	     "The state name associated with the low state
	     of the battery."
     ::= { wwpLeosChassisBatteryModule 6 }

 wwpLeosChassisBatteryGoodStateName     OBJECT-TYPE
     SYNTAX           OCTET STRING (SIZE(1..128))  
     MAX-ACCESS       read-write
     STATUS           current
     DESCRIPTION
	     "The state name associated with the good state
	     of the battery."
     ::= { wwpLeosChassisBatteryModule 7 }
 
 wwpLeosChassisBatteryBadStateName     OBJECT-TYPE
     SYNTAX           OCTET STRING (SIZE(1..128))  
     MAX-ACCESS       read-write
     STATUS           current
     DESCRIPTION
	     "The state name associated with the bad state
	     of the battery."
     ::= { wwpLeosChassisBatteryModule 8 }
     
 wwpLeosChassisBatteryPresentStateName     OBJECT-TYPE
     SYNTAX           OCTET STRING (SIZE(1..128))  
     MAX-ACCESS       read-write
     STATUS           current
     DESCRIPTION
	     "The state name associated with the battery state 
             'present'." 
     ::= { wwpLeosChassisBatteryModule 9 }
     
 wwpLeosChassisBatteryMissingStateName     OBJECT-TYPE
     SYNTAX           OCTET STRING (SIZE(1..128))  
     MAX-ACCESS       read-write
     STATUS           current
     DESCRIPTION
	     "The state name associated with the battery state 
             'missing'." 
     ::= { wwpLeosChassisBatteryModule 10 }
    
 wwpLeosChassisBatteryPowerPrimaryStateName     OBJECT-TYPE
     SYNTAX           OCTET STRING (SIZE(1..128))  
     MAX-ACCESS       read-write
     STATUS           current
     DESCRIPTION
             "The state name associated with the state when the
              device is on primary power." 
     ::= { wwpLeosChassisBatteryModule 11 }
      
 wwpLeosChassisBatteryPowerBatteryStateName     OBJECT-TYPE
     SYNTAX           OCTET STRING (SIZE(1..128))  
     MAX-ACCESS       read-write
     STATUS           current
     DESCRIPTION
	     "The state name associated with the state when the
             device is on battery power." 
     ::= { wwpLeosChassisBatteryModule 12 }
     
 
      
 wwpLeosChassisBatteryLowStateNotifEnabled OBJECT-TYPE
     SYNTAX      TruthValue
     MAX-ACCESS  read-write
     STATUS      current
     DESCRIPTION
             "This variable indicates whether the system
             will generate the wwpLeosChassisBatteryStatusNotification
             in case of battery state changing from normal to low
             or vice versa. 
             A false value prevents this notifications
             from being generated by this system."
    DEFVAL { true }
    ::= { wwpLeosChassisBatteryModule 13 }
     
 wwpLeosChassisBatteryBadStateNotifEnabled OBJECT-TYPE
     SYNTAX      TruthValue
     MAX-ACCESS  read-write
     STATUS      current
     DESCRIPTION
             "This variable indicates whether the system
             will generate the wwpLeosChassisBatteryStatusNotification
             in case of battery state changing from good to bad
             or vice versa.
             A false value prevents this notifications
             from being generated by this system."
    DEFVAL { true }
    ::= { wwpLeosChassisBatteryModule 14 }
    
 wwpLeosChassisBatteryMissingStateNotifEnabled OBJECT-TYPE
     SYNTAX      TruthValue
     MAX-ACCESS  read-write
     STATUS      current
     DESCRIPTION
             "This variable indicates whether the system
             will generate the wwpLeosChassisBatteryStatusNotification
             in case of battery state changing from present to missing
             or vice versa.
             A false value prevents this notifications
             from being generated by this system."
    DEFVAL { true }
    ::= { wwpLeosChassisBatteryModule 15 }
    
 wwpLeosChassisBatteryPowerNotifEnabled OBJECT-TYPE
     SYNTAX      TruthValue
     MAX-ACCESS  read-write
     STATUS      current
     DESCRIPTION
             "This variable indicates whether the system
             will generate the wwpLeosChassisBatteryStatusNotification
             in case of input power changing from primary to battery
             or vice versa.
             A false value prevents this notifications
             from being generated by this system."
    DEFVAL { true }
    ::= { wwpLeosChassisBatteryModule 16 }         
   
 wwpLeosChassisPostErrorCategory OBJECT-TYPE
     SYNTAX      INTEGER {
     					chassis(1),
     					blade(2),
     					port(3)
     				}
     MAX-ACCESS  accessible-for-notify
     STATUS      current
     DESCRIPTION
             "This variable indicates the category of post errors. This
              object is sent out as one of the binding in Post Error
              Notification."    
    ::= { wwpLeosChassisNotifAttrs 1 }
    
  wwpLeosChassisPostErrorValue OBJECT-TYPE
     SYNTAX      INTEGER (0..65535)
     MAX-ACCESS  accessible-for-notify
     STATUS      current
     DESCRIPTION
             "This variable indicates the value associated with category 
              wwpLeosChassisPostErrorCategory. If this value is 0 then 
              no value corresponds to wwpLeosChassisPostErrorCategory."
    DEFVAL { 0 }
    ::= { wwpLeosChassisNotifAttrs 2 }
 
  wwpLeosChassisPostErrorCode OBJECT-TYPE
     SYNTAX      Unsigned32
     MAX-ACCESS  accessible-for-notify
     STATUS      current
     DESCRIPTION
             "This variable indicates the post error code."    
    ::= { wwpLeosChassisNotifAttrs 3 }
    
  wwpLeosChassisPostErrorMsg OBJECT-TYPE  	 
     SYNTAX      DisplayString
     MAX-ACCESS  accessible-for-notify
     STATUS      current
     DESCRIPTION
             "This variable indicates the post error message 
              associated with category wwpLeosChassisPostErrorCategory."    
    ::= { wwpLeosChassisNotifAttrs 4 }

  wwpLeosChassisRebootReasonErrorType OBJECT-TYPE  	 
     SYNTAX      INTEGER {  
                                unknown(1),
                                snmp(2),
                                powerFailure(3),
                                appload(4),
                                errorHandler(5),
                                watchDog(6),
                                upgrade(7),
                                cli(8),           
                                resetButton(9),
                                serviceModeChange(10),
                                guardianReboot(11),
                                guardianSaosRestart(12)
                                }
     MAX-ACCESS  accessible-for-notify
     STATUS      current
     DESCRIPTION
             "This variable indicates the type of reboot reasons
              included in the wwpLeosChassisRebootNotification trap."    
    ::= { wwpLeosChassisNotifAttrs 5 }
  
  wwpLeosChassisSnmpState OBJECT-TYPE  	 
     SYNTAX      INTEGER {
     				disabled(1),
     				enabled(2)
     				}
     MAX-ACCESS  accessible-for-notify
     STATUS      current
     DESCRIPTION
             "This variable indicates the snmp state."    
    ::= { wwpLeosChassisNotifAttrs 6 }    
     
 --
 -- Notifications
 -- 
 wwpLeosChassisPowerSupplyStatusNotification NOTIFICATION-TYPE
	OBJECTS	{
                wwpLeosChassisPowerSupplyNum, 
                wwpLeosChassisPowerSupplyState,
                wwpLeosChassisPowerSupplyType              
		}
	STATUS	current
	DESCRIPTION
		"A wwpLeosChassisPowerSupplyStatusNotification is sent if a 
		power supply state is changed."
	::= { wwpLeosChassisMIBNotifications 1 }
 
 wwpLeosChassisFanModuleNotification NOTIFICATION-TYPE
	OBJECTS	{
		wwpLeosChassisFanModuleNum,		
		wwpLeosChassisFanModuleStatus
		}
	STATUS	current
	DESCRIPTION
		"A wwpLeosChassisFanModuleNotification is sent if the 
		fan state changes."
	::= { wwpLeosChassisMIBNotifications 2 }

 wwpLeosChassisTempNotification NOTIFICATION-TYPE
	OBJECTS	{
                wwpLeosChassisTempSensorState,
                wwpLeosChassisTempSensorValue,
                wwpLeosChassisTempSensorHighThreshold,
                wwpLeosChassisTempSensorLowThreshold          
		}
	STATUS	current
	DESCRIPTION
		"A wwpLeosChassisTempNotification is sent if the 
		wwpLeosChassisTempSensorState is changed."
	::= { wwpLeosChassisMIBNotifications 3 }

 wwpLeosChassisPowerSwitchNotification NOTIFICATION-TYPE
	OBJECTS	{
                wwpPowerSwitchingOp           
		}
	STATUS	current
	DESCRIPTION
		"A wwpLeosChassisPowerSwitchNotification is sent if the 
		input power supply is switched to Battery from the 
                AC power or switched from the Battery to the AC Power."
	::= { wwpLeosChassisMIBNotifications 4 }

 wwpLeosChassisBatteryStatusNotification NOTIFICATION-TYPE
	OBJECTS	{
	           wwpLeosChassisBatteryStatus
                }
	STATUS	current
	DESCRIPTION
		"A wwpLeosChassisBatteryStatusNotification is sent if the 
		Battery status changes. If the device supports the 
                configurable battery state names, then the corresponding 
                battery state name should also be sent with this notification." 
	::= { wwpLeosChassisMIBNotifications 5 }

 wwpLeosChassisBatteryVoltageLevelNotification NOTIFICATION-TYPE
	OBJECTS	{
	        wwpLeosChassisBatteryVoltageLevel
                }
	STATUS	current
	DESCRIPTION
		"A wwpLeosChassisBatteryVoltageLevelNotification is sent if the 
		Battery voltage level changes from normal to low or vice versa.
                If the device supports the configurable battery state names, then 
                the corresponding battery state name should also be sent with 
                this notification." 
	::= { wwpLeosChassisMIBNotifications 6 }
 
 wwpLeosChassisBatteryConditionNotification NOTIFICATION-TYPE
	OBJECTS	{
	        wwpLeosChassisBatteryCondition
                }
	STATUS	current
	DESCRIPTION
		"A wwpLeosChassisBatteryConditionNotification is sent if the 
		Battery condition changes from good to bad or vice versa.
                If the device supports the configurable battery state names, then 
                the corresponding battery state name should also be sent with 
                this notification." 
	::= { wwpLeosChassisMIBNotifications 7 }
         
 wwpLeosChassisPowerSourceNotification NOTIFICATION-TYPE
	OBJECTS	{
	        wwpLeosChassisPowerSource
                }
	STATUS	current
	DESCRIPTION
		"A wwpLeosChassisPowerSourceNotification is sent if the 
		Battery input power source changes from battery to primary
                power or vice versa. A device which supports 
                wwpLeosChassisPowerSwitchNotification should not support this
                notification. If the device supports the configurable 
                battery state names, then the corresponding battery state 
                name should also be sent with this notification." 
	::= { wwpLeosChassisMIBNotifications 8 }    
 
 wwpLeosChassisPostErrorNotification NOTIFICATION-TYPE
	OBJECTS	{				
	        	wwpLeosChassisPostErrorCategory,
	        	wwpLeosChassisPostErrorValue,
	        	wwpLeosChassisPostErrorCode,
	        	wwpLeosChassisPostErrorMsg
            }
	STATUS	current
	DESCRIPTION
		"A wwpLeosChassisPostErrorNotification is sent after cold start trap 
		 if the device detects post errors." 
	::= { wwpLeosChassisMIBNotifications 9 }

 wwpLeosChassisRebootNotification NOTIFICATION-TYPE
	OBJECTS	{
				wwpLeosChassisRebootReasonErrorType				  	
            }
	STATUS	current
	DESCRIPTION
		"A wwpLeosChassisRebootNotification is sent whenever device is rebooted using CLI / SNMP." 
	::= { wwpLeosChassisMIBNotifications 10 }
 
 wwpLeosChassisSnmpStateNotification NOTIFICATION-TYPE
	OBJECTS	{
				wwpLeosChassisSnmpState
            }
	STATUS	current
	DESCRIPTION
		"This notification is sent everytime SNMP operational state is changed.
		 If SNMP is globally disabled then device will not send COLD start Trap but 
		 instead it will send wwpLeosChassisSnmpStateNotification notification." 
	::= { wwpLeosChassisMIBNotifications 11 }     

wwpLeosChassisDyingGaspNotification NOTIFICATION-TYPE
	OBJECTS	{
				wwpLeosChassisDeviceId,
				wwpLeosChassisHardwareVersion,
				wwpLeosChassisSerialNumber,
				wwpLeosChassisMacAddress,
				wwpLeosChassisMfgDate,
				wwpLeosChassisParamVersion
            }
	STATUS	current
	DESCRIPTION
		"This notification is sent when the system goes down" 
	::= { wwpLeosChassisMIBNotifications 12 }     
  
  wwpLeosChassisDoorStatusChangeNotification NOTIFICATION-TYPE
	OBJECTS	{
				wwpLeosChassisDeviceId,
				wwpLeosChassisHardwareVersion,
				wwpLeosChassisSerialNumber,
				wwpLeosChassisMacAddress,
				wwpLeosChassisMfgDate,
				wwpLeosChassisParamVersion,
				wwpLeosChassisInnerDoorStatus,
				wwpLeosChassisOuterDoorStatus
            }
	STATUS	deprecated
	DESCRIPTION
		"This notification is sent each time the chassis door is opened." 
	::= { wwpLeosChassisMIBNotifications 13 }
  
  wwpLeosChassisInnerDoorStatusChangeNotification NOTIFICATION-TYPE
  	OBJECTS	{
				wwpLeosChassisDeviceId,
				wwpLeosChassisHardwareVersion,
				wwpLeosChassisSerialNumber,
				wwpLeosChassisMacAddress,
				wwpLeosChassisMfgDate,
				wwpLeosChassisParamVersion,
				wwpLeosChassisInnerDoorStatus
            }
	STATUS	current
	DESCRIPTION
		"This notification is sent each time the chassis inner door status changes." 
	::= { wwpLeosChassisMIBNotifications 14 }

  wwpLeosChassisOuterDoorStatusChangeNotification NOTIFICATION-TYPE
  	OBJECTS	{
				wwpLeosChassisDeviceId,
				wwpLeosChassisHardwareVersion,
				wwpLeosChassisSerialNumber,
				wwpLeosChassisMacAddress,
				wwpLeosChassisMfgDate,
				wwpLeosChassisParamVersion,
				wwpLeosChassisOuterDoorStatus
            }
	STATUS	current
	DESCRIPTION
		"This notification is sent each time the chassis outer door status changes." 
	::= { wwpLeosChassisMIBNotifications 15 }
	
	wwpLeosChassisExternalAlarmStatusChangeNotification NOTIFICATION-TYPE
	OBJECTS	{
				wwpLeosChassisDeviceId,
				wwpLeosChassisHardwareVersion,
				wwpLeosChassisSerialNumber,
				wwpLeosChassisMacAddress,
				wwpLeosChassisMfgDate,
				wwpLeosChassisParamVersion,
				wwpLeosChassisOuterDoorStatus,
				wwpLeosChassisExternalAlarm,
				wwpLeosChassisExternalAlarmStatus
            }
	STATUS	current
	DESCRIPTION
		"This notification is sent each time the chassis external alarm status changes." 
	::= { wwpLeosChassisMIBNotifications 16 }
  
  wwpLeosChassisDoorAlarmStatusChangeNotification NOTIFICATION-TYPE
	OBJECTS	{
				wwpLeosChassisDoorAlarmIndex,
				wwpLeosChassisDoorAlarmStatus
            }
	STATUS	current
	DESCRIPTION
		"This notification is sent each time the door alarm status changes." 
	::= { wwpLeosChassisMIBNotifications 17 }
  
	
 --
 -- Platform Capability
 -- 

 wwpLeosChassisPlatformCapsMaxPhysPorts  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..28)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of physical ports supported on this machine."
     ::= { wwpLeosChassisPlatformCaps 1 }

 wwpLeosChassisPlatformCapsMaxAggrPorts  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..14)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of LAGs supported on this machine."
     ::= { wwpLeosChassisPlatformCaps 2 }

 wwpLeosChassisPlatformCapsMaxVlans  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..4064)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of VLANs supported on this machine."
     ::= { wwpLeosChassisPlatformCaps 3 }

 wwpLeosChassisPlatformCapsMaxIgmpSnoopVlans  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..32)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of IGMP VLANs snooped simultaneously on this machine."
     ::= { wwpLeosChassisPlatformCaps 4 }

 wwpLeosChassisPlatformCapsMaxMulticastgroups  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..1024)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of IGMP multicast groups supported on this machine."
     ::= { wwpLeosChassisPlatformCaps 5 }

 wwpLeosChassisPlatformCapsMaxRstpDomains  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..16)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of RSTP domains supported on this machine."
     ::= { wwpLeosChassisPlatformCaps 6 }

 wwpLeosChassisPlatformCapsMaxTunnels  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..64)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of transport tunnels supported on this machine."
     ::= { wwpLeosChassisPlatformCaps 7 }

 wwpLeosChassisPlatformCapsMaxIngressTunnels  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..32)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of ingress tunnels supported on this machine."
     ::= { wwpLeosChassisPlatformCaps 8 }

 wwpLeosChassisPlatformCapsMaxEgressTunnels  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..32)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of egress tunnels supported on this machine."
     ::= { wwpLeosChassisPlatformCaps 9 }

 wwpLeosChassisPlatformCapsMaxVcs  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..127)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of virtual circuits supported on this machine."
     ::= { wwpLeosChassisPlatformCaps 10 }

 wwpLeosChassisPlatformCapsMaxVss  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..127)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of virtual switches supported on this machine."
     ::= { wwpLeosChassisPlatformCaps 11 }

 wwpLeosChassisPlatformCapsMaxVsMembers  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..5334)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of virtual switch members supported on this machine."
     ::= { wwpLeosChassisPlatformCaps 12 }

 wwpLeosChassisPlatformCapsMaxLearnedMacs  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..20000)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of learned MACs supported on this machine."
     ::= { wwpLeosChassisPlatformCaps 13 }

 wwpLeosChassisPlatformCapsMaxFsmtEntries  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..140)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of FSMT entries supported on this machine."
     ::= { wwpLeosChassisPlatformCaps 14 }

 wwpLeosChassisPlatformCapsMaxFsmtCosEntries  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..34)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of FSMT COS entries supported on this machine."
     ::= { wwpLeosChassisPlatformCaps 15 }

 wwpLeosChassisPlatformCapsMaxL4ProtEntries  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..62)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of L4 Prot/P entries supported on this machine."
     ::= { wwpLeosChassisPlatformCaps 16 }

 wwpLeosChassisPlatformCapsMaxSltEntries  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..99)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of SLT entries supported on this machine."
     ::= { wwpLeosChassisPlatformCaps 17 }

 wwpLeosChassisPlatformCapsMaxSactEntries  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..2074)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of SACT entries supported on this machine."
     ::= { wwpLeosChassisPlatformCaps 18 }

 wwpLeosChassisPlatformCapsMaxSmtEntries  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..1024)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of SMT entries supported on this machine."
     ::= { wwpLeosChassisPlatformCaps 19 }

 wwpLeosChassisPlatformCapsMaxEprSnids  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..8)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of EPR snids supported on this machine."
     ::= { wwpLeosChassisPlatformCaps 20 }

 wwpLeosChassisPlatformCapsMaxSltWildcards  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..3)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of SLT wildcards supported on this machine."
     ::= { wwpLeosChassisPlatformCaps 21 }

 wwpLeosChassisPlatformCapsVlanTranslation  OBJECT-TYPE
     SYNTAX        TruthValue
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "Denotes whether VLAN translation is supported on this machine."
     ::= { wwpLeosChassisPlatformCaps 22 }

 wwpLeosChassisPlatformCapsProtocolFilters  OBJECT-TYPE
     SYNTAX        TruthValue
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "Denotes whether protocol filters are supported on this machine."
     ::= { wwpLeosChassisPlatformCaps 23 }

 wwpLeosChassisPlatformCapsMultiSubsPerPort  OBJECT-TYPE
     SYNTAX        TruthValue
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "Denotes whether multiple subscribers per port are supported on this machine."
     ::= { wwpLeosChassisPlatformCaps 24 }

 wwpLeosChassisPlatformCapsVplsFpga  OBJECT-TYPE
     SYNTAX        TruthValue
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "Denotes whether VPLS FPGA hardware exists on this machine."
     ::= { wwpLeosChassisPlatformCaps 25 }

 wwpLeosChassisPlatformCapsPbtFpga  OBJECT-TYPE
     SYNTAX        TruthValue
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "Denotes whether PBT FPGA hardware exists on this machine."
     ::= { wwpLeosChassisPlatformCaps 26 }

 wwpLeosChassisPlatformCapsAoamFpga  OBJECT-TYPE
     SYNTAX        TruthValue
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "Denotes whether AOAM FPGA hardware exists on this machine."
     ::= { wwpLeosChassisPlatformCaps 27 }

 wwpLeosChassisPlatformCapsDcPower  OBJECT-TYPE
     SYNTAX        TruthValue
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "Denotes whether DC Power is supported on this machine."
     ::= { wwpLeosChassisPlatformCaps 29 }

 wwpLeosChassisPlatformCapsAcPower  OBJECT-TYPE
     SYNTAX        TruthValue
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "Denotes whether AC Power is supported on this machine."
     ::= { wwpLeosChassisPlatformCaps 30 }

 wwpLeosChassisPlatformCapsRedunPower  OBJECT-TYPE
     SYNTAX        TruthValue
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "Denotes whether Redundant Power is supported on this machine."
     ::= { wwpLeosChassisPlatformCaps 31 }

 --
 -- Resource Counts
 -- 

 wwpLeosChassisResourcesMaxPorts  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..28)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of ports on this machine."
     ::= { wwpLeosChassisResourceCounts 1 }

 wwpLeosChassisResourcesFreePorts  OBJECT-TYPE
     SYNTAX        Gauge32 (0..28)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of ports free on this machine."
     ::= { wwpLeosChassisResourceCounts 2 }

 wwpLeosChassisResourcesMaxAggrPorts  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..14)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of LAG ports on this machine."
     ::= { wwpLeosChassisResourceCounts 3 }

 wwpLeosChassisResourcesFreeAggrs  OBJECT-TYPE
     SYNTAX        Gauge32 (0..14)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of LAG ports free on this machine."
     ::= { wwpLeosChassisResourceCounts 4 }

 wwpLeosChassisResourcesMaxPortStateGrps  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..21)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of Port State groups on this machine."
     ::= { wwpLeosChassisResourceCounts 5 }

 wwpLeosChassisResourcesFreePortStateGrps  OBJECT-TYPE
     SYNTAX        Gauge32 (0..21)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of Port State Groups free on this machine."
     ::= { wwpLeosChassisResourceCounts 6 }

 wwpLeosChassisResourcesMaxVlans  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..4064)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of VLANs on this machine."
     ::= { wwpLeosChassisResourceCounts 7 }

 wwpLeosChassisResourcesFreeVlans  OBJECT-TYPE
     SYNTAX        Gauge32 (0..4064)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of VLANs free on this machine."
     ::= { wwpLeosChassisResourceCounts 8 }

 wwpLeosChassisResourcesMaxVlanMembers  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..170688)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of VLAN members on this machine."
     ::= { wwpLeosChassisResourceCounts 9 }

 wwpLeosChassisResourcesFreeVlanMembers  OBJECT-TYPE
     SYNTAX        Gauge32 (0..170688)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of VLAN members free on this machine."
     ::= { wwpLeosChassisResourceCounts 10 }

 wwpLeosChassisResourcesMaxEprSnets  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..8)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of EPR VLANs on this machine."
     ::= { wwpLeosChassisResourceCounts 11 }

 wwpLeosChassisResourcesFreeEprSnets  OBJECT-TYPE
     SYNTAX        Gauge32 (0..8)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of EPR VLANs free on this machine."
     ::= { wwpLeosChassisResourceCounts 12 }

 wwpLeosChassisResourcesMaxMcastSnets  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..32)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of multicast VLANs on this machine."
     ::= { wwpLeosChassisResourceCounts 13 }

 wwpLeosChassisResourcesFreeMcastSnets  OBJECT-TYPE
     SYNTAX        Gauge32 (0..32)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of multicast VLANs free on this machine."
     ::= { wwpLeosChassisResourceCounts 14 }

 wwpLeosChassisResourcesMaxMcastGroups  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..1024)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of multicast groups on this machine."
     ::= { wwpLeosChassisResourceCounts 15 }

 wwpLeosChassisResourcesFreeMcastGroups  OBJECT-TYPE
     SYNTAX        Gauge32 (0..1024)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of multicast groups free on this machine."
     ::= { wwpLeosChassisResourceCounts 16 }

 wwpLeosChassisResourcesMaxDhcpRelayAgnts  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..16)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of DHCP Relay Agents on this machine."
     ::= { wwpLeosChassisResourceCounts 17 }

 wwpLeosChassisResourcesFreeDhcpRelayAgnts  OBJECT-TYPE
     SYNTAX        Gauge32 (0..16)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of DHCP Relay Agents free on this machine."
     ::= { wwpLeosChassisResourceCounts 18 }

 wwpLeosChassisResourcesMaxTunnels  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..64)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of tunnels on this machine."
     ::= { wwpLeosChassisResourceCounts 19 }

 wwpLeosChassisResourcesFreeTunnels  OBJECT-TYPE
     SYNTAX        Gauge32 (0..64)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of tunnels free on this machine."
     ::= { wwpLeosChassisResourceCounts 20 }

 wwpLeosChassisResourcesMaxIngressTunnels  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..32)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of Ingress tunnels on this machine."
     ::= { wwpLeosChassisResourceCounts 21 }

 wwpLeosChassisResourcesFreeIngressTunnels  OBJECT-TYPE
     SYNTAX        Gauge32 (0..32)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of Ingress tunnels free on this machine."
     ::= { wwpLeosChassisResourceCounts 22 }

 wwpLeosChassisResourcesMaxEgressTunnels  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..32)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of Egress tunnels on this machine."
     ::= { wwpLeosChassisResourceCounts 23 }

 wwpLeosChassisResourcesFreeEgressTunnels  OBJECT-TYPE
     SYNTAX        Gauge32 (0..32)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of Egress tunnels free on this machine."
     ::= { wwpLeosChassisResourceCounts 24 }

 wwpLeosChassisResourcesMaxVcs  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..127)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of Virtual Circuits on this machine."
     ::= { wwpLeosChassisResourceCounts 25 }

 wwpLeosChassisResourcesFreeVcs  OBJECT-TYPE
     SYNTAX        Gauge32 (0..127)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of Virtual Circuits free on this machine."
     ::= { wwpLeosChassisResourceCounts 26 }

 wwpLeosChassisResourcesMaxVss  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..127)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of Virtual Switches on this machine."
     ::= { wwpLeosChassisResourceCounts 27 }

 wwpLeosChassisResourcesFreeVss  OBJECT-TYPE
     SYNTAX        Gauge32 (0..127)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of Virtual Switches free on this machine."
     ::= { wwpLeosChassisResourceCounts 28 }

 wwpLeosChassisResourcesMaxVsMembers  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..5334)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of Virtual Switch members on this machine."
     ::= { wwpLeosChassisResourceCounts 29 }

 wwpLeosChassisResourcesFreeVsMembers  OBJECT-TYPE
     SYNTAX        Gauge32 (0..5334)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of Virtual Switch members free on this machine."
     ::= { wwpLeosChassisResourceCounts 30 }

 wwpLeosChassisResourcesMaxSlevelWcards  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..3)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of Service Level Wildcards on this machine."
     ::= { wwpLeosChassisResourceCounts 31 }

 wwpLeosChassisResourcesFreeSlevelWcards  OBJECT-TYPE
     SYNTAX        Gauge32 (0..3)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of Service Level Wildcards free on this machine."
     ::= { wwpLeosChassisResourceCounts 32 }

 wwpLeosChassisResourcesMaxSlevels  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..102)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of Service Level Wildcards on this machine."
     ::= { wwpLeosChassisResourceCounts 33 }

 wwpLeosChassisResourcesFreeSlevels  OBJECT-TYPE
     SYNTAX        Gauge32 (0..102)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of Service Levels free on this machine."
     ::= { wwpLeosChassisResourceCounts 34 }

 wwpLeosChassisResourcesMaxSmappings  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..140)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of Service Mappings on this machine."
     ::= { wwpLeosChassisResourceCounts 35 }

 wwpLeosChassisResourcesFreeSmappings  OBJECT-TYPE
     SYNTAX        Gauge32 (0..140)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of Service Mappings free on this machine."
     ::= { wwpLeosChassisResourceCounts 36 }

 wwpLeosChassisResourcesMaxSmappingCosResources  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..34)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of Service Mapping COS resources on this machine."
     ::= { wwpLeosChassisResourceCounts 37 }

 wwpLeosChassisResourcesFreeSmappingCosResources  OBJECT-TYPE
     SYNTAX        Gauge32 (0..34)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of Service Mapping COS resources free on this machine."
     ::= { wwpLeosChassisResourceCounts 38 }

 wwpLeosChassisResourcesMaxSmappingPrtclResources  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..62)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of Service Mapping Protocol resources on this machine."
     ::= { wwpLeosChassisResourceCounts 39 }

 wwpLeosChassisResourcesFreeSmappingPrtclResources  OBJECT-TYPE
     SYNTAX        Gauge32 (0..62)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of Service Mapping Protocol resources free on this machine."
     ::= { wwpLeosChassisResourceCounts 40 }

 wwpLeosChassisResourcesMaxQosResEgs  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..99)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of QosResEg resources on this machine."
     ::= { wwpLeosChassisResourceCounts 41 }

 wwpLeosChassisResourcesFreeQosResEgs  OBJECT-TYPE
     SYNTAX        Gauge32 (0..99)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of QosResEg resources free on this machine."
     ::= { wwpLeosChassisResourceCounts 42 }

 wwpLeosChassisResourcesMaxTprofGblCscdEntries  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..3)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of TprofGblCscdEntries on this machine."
     ::= { wwpLeosChassisResourceCounts 43 }

 wwpLeosChassisResourcesFreeTprofGblCscdEntries  OBJECT-TYPE
     SYNTAX        Gauge32 (0..3)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of TprofGblCscdEntries free on this machine."
     ::= { wwpLeosChassisResourceCounts 44 }

 wwpLeosChassisResourcesMaxTprofCscdEntries  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..126)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of TprofCscdEntries on this machine."
     ::= { wwpLeosChassisResourceCounts 45 }

 wwpLeosChassisResourcesFreeTprofCscdEntries  OBJECT-TYPE
     SYNTAX        Gauge32 (0..126)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of TprofCscdEntries free on this machine."
     ::= { wwpLeosChassisResourceCounts 46 }

 wwpLeosChassisResourcesMaxTprofStdEntries  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..336)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of TprofStdEntries on this machine."
     ::= { wwpLeosChassisResourceCounts 47 }

 wwpLeosChassisResourcesFreeTprofStdEntries  OBJECT-TYPE
     SYNTAX        Gauge32 (0..336)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of TprofStdEntries free on this machine."
     ::= { wwpLeosChassisResourceCounts 48 }

 wwpLeosChassisResourcesMaxSaccessEntries  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..2074)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of SaccessEntries on this machine."
     ::= { wwpLeosChassisResourceCounts 49 }

 wwpLeosChassisResourcesFreeSaccessEntries  OBJECT-TYPE
     SYNTAX        Gauge32 (0..2074)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of SaccessEntries free on this machine."
     ::= { wwpLeosChassisResourceCounts 50 }

 wwpLeosChassisResourcesMaxSmacEntries  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..1024)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of SmacEntries on this machine."
     ::= { wwpLeosChassisResourceCounts 51 }

 wwpLeosChassisResourcesFreeSmacEntries  OBJECT-TYPE
     SYNTAX        Gauge32 (0..1024)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of SmacEntries free on this machine."
     ::= { wwpLeosChassisResourceCounts 52 }

 wwpLeosChassisResourcesMaxDrvNoLrnSacResources  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..2048)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of DrvNoLrnSacResources on this machine."
     ::= { wwpLeosChassisResourceCounts 53 }

 wwpLeosChassisResourcesFreeDrvNoLrnSacResources  OBJECT-TYPE
     SYNTAX        Gauge32 (0..2048)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of DrvNoLrnSacResources free on this machine."
     ::= { wwpLeosChassisResourceCounts 54 }

 wwpLeosChassisResourcesMaxLearnEntries  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..20000)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of LearnEntries on this machine."
     ::= { wwpLeosChassisResourceCounts 55 }

 wwpLeosChassisResourcesFreeLearnEntries  OBJECT-TYPE
     SYNTAX        Gauge32 (0..20000)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of LearnEntries free on this machine."
     ::= { wwpLeosChassisResourceCounts 56 }

 wwpLeosChassisResourcesMaxCustomPrtcls  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..16)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of CustomPrtcls on this machine."
     ::= { wwpLeosChassisResourceCounts 57 }

 wwpLeosChassisResourcesFreeCustomPrtcls  OBJECT-TYPE
     SYNTAX        Gauge32 (0..16)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of CustomPrtcls free on this machine."
     ::= { wwpLeosChassisResourceCounts 58 }

 wwpLeosChassisResourcesMaxPrtcls  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..32)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of Prtcls on this machine."
     ::= { wwpLeosChassisResourceCounts 59 }

 wwpLeosChassisResourcesFreePrtcls  OBJECT-TYPE
     SYNTAX        Gauge32 (0..32)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of Prtcls free on this machine."
     ::= { wwpLeosChassisResourceCounts 60 }

 wwpLeosChassisResourcesMaxPrtclFilters  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..64)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of PrtclFilters on this machine."
     ::= { wwpLeosChassisResourceCounts 61 }

 wwpLeosChassisResourcesFreePrtclFilters  OBJECT-TYPE
     SYNTAX        Gauge32 (0..64)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of PrtclFilters free on this machine."
     ::= { wwpLeosChassisResourceCounts 62 }

 wwpLeosChassisResourcesMaxPrtclFilterMembs  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..512)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of PrtclFilterMembs on this machine."
     ::= { wwpLeosChassisResourceCounts 63 }

 wwpLeosChassisResourcesFreePrtclFilterMembs  OBJECT-TYPE
     SYNTAX        Gauge32 (0..512)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of PrtclFilterMembs free on this machine."
     ::= { wwpLeosChassisResourceCounts 64 }

 wwpLeosChassisResourcesMaxBcastFilters  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..64)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of BcastFilters on this machine."
     ::= { wwpLeosChassisResourceCounts 65 }

 wwpLeosChassisResourcesFreeBcastFilters  OBJECT-TYPE
     SYNTAX        Gauge32 (0..64)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of BcastFilters free on this machine."
     ::= { wwpLeosChassisResourceCounts 66 }

 wwpLeosChassisResourcesMaxBcastFilterMembs  OBJECT-TYPE
     SYNTAX        Unsigned32 (0..4064)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The maximum number of BcastFilterMembs on this machine."
     ::= { wwpLeosChassisResourceCounts 67 }

 wwpLeosChassisResourcesFreeBcastFilterMembs  OBJECT-TYPE
     SYNTAX        Gauge32 (0..4064)
     MAX-ACCESS    read-only 
     STATUS        current
     DESCRIPTION
             "The number of BcastFilterMembs free on this machine."
     ::= { wwpLeosChassisResourceCounts 68 }

  END

 
