-- MIB Revision 4

CIENA-OME6500-ALARM-EXT-MIB DEFINITIONS ::= BEGIN

   IMPORTS
       cienaGenericMIBs    FROM CIENA-SMI

       nlmLogName, nlmLogIndex FROM NOTIFICATION-LOG-MIB

       TEXTUAL-CONVENTION,
       DateAndTime         FROM SNMPv2-TC
        
       MODULE-IDENTITY,
       OBJECT-IDENTITY,
       OBJECT-TYPE,
       NOTIFICATION-TYPE,
       Integer32           FROM SNMPv2-SMI

       SnmpAdminString     FROM SNMP-FRAMEWORK-MIB;

ome6500ExtAlarmMIB MODULE-IDENTITY
    LAST-UPDATED "201807090000Z"
    ORGANIZATION "Ciena Corp." 
    CONTACT-INFO 
        	"  Mib Meister
               115 North Sullivan Road
               Spokane Valley, WA 99037
               USA            
               Phone:  +1 509 242 9000
               Email:  support@ciena.com" 

     DESCRIPTION  "This module contains objects that extend the IETF Alarm MIB"
     
     -- Revision history
      REVISION "201507150000Z"
      DESCRIPTION "Initial Version - created for OME6500 REL 11.1"         

      REVISION "201807090000Z"
      DESCRIPTION "Ome6500ExtAlarmProbableCause  enum list was updated for OME6500 REL12.4(1 - 7030)."

     ::= { cienaGenericMIBs 6 }

ome6500ExtAlarmObjects    OBJECT IDENTIFIER ::= { ome6500ExtAlarmMIB 1 }
ome6500AlarmObjects       OBJECT IDENTIFIER ::= { ome6500ExtAlarmMIB 2 }


-- Textual Conventions

Ome6500ExtAlarmEventType ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
         "Ciena OME6500 version of IANA Event Type"
    SYNTAX       INTEGER
          {
          other  (1),
          communicationsAlarm  (2),
          qualityOfServiceAlarm  (3),
          processingErrorAlarm  (4),
          equipmentAlarm  (5),
          environmentalAlarm  (6),
          integrityViolation  (7),
          operationalViolation  (8),
          physicalViolation  (9),
          securityServiceOrMechanismViolation  (10),
          timeDomainViolation (11)
          }

-- Probable causes removed from this version, as the version we give
-- customers contains duplicate probable causes which mosy does not like
-- internally we don't use the probable cause values anyway.

Ome6500ExtAlarmProbableCause ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
         "Ciena OME6500 version of IANA Probable Cause"
    SYNTAX       INTEGER
          {
           indeterminate (0),
           aIS (1),
           callSetUpFailure (2),
           degradedSignal (3),
           farEndReceiverFailure (4),
           framingError (5),
           lossOfFrame (6),
           lossOfPointer (7),
           lossOfSignal (8),
           payloadTypeMismatch (9),
           transmissionError (10),
           remoteAlarmInterface (11),
           excessiveBER (12),
           pathTraceMismatch (13),
           unavailable (14),
           signalLabelMismatch (15),
           lossOfMultiFrame (16),
           receiveFailure (17),
           transmitFailure (18),
           modulationFailure (19),
           demodulationFailure (20),
           broadcastChannelFailure (21),
           connectionEstablishmentError (22),
           invalidMessageReceived (23),
           localNodeTransmissionError (24),
           remoteNodeTransmissionError (25),
           routingFailure (26),
           thresholdCrossing (48),
           backplaneFailure (51),
           dataSetProblem (52),
           equipmentIdentifierDuplication (53),
           externalIFDeviceProblem (54),
           lineCardProblem (55),
           multiplexerProblem (56),
           nEIdentifierDuplication (57),
           powerProblem (58),
           processorProblem (59),
           protectionPathFailure (60),
           receiverFailure (61),
           replaceableUnitMissing (62),
           replaceableUnitTypeMismatch (63),
          synchronizationSourceMismatch (64),
           terminalProblem (65),
           timingProblem (66),
           transmitterFailure (67),
           trunkCardProblem (68),
           replaceableUnitProblem (69),
           realTimeClockFailure (70),
           antennaFailure (71),
           batteryChargingFailure (72),
           diskFailure (73),
           frequencyHoppingFailure (74),
           iODeviceError (75),
           lossOfSynchronisation (76),
           lossOfRedundancy (77),
           powerSupplyFailure (78),
           signalQualityEvaluationFailure (79),
           tranceiverFailure (80),
           airCompressorFailure (101),
           airConditioningFailure (102),
           airDryerFailure (103),
           batteryDischarging (104),
           batteryFailure (105),
           commercialPowerFailure (106),
           coolingFanFailure (107),
           engineFailure (108),
           fireDetectorFailure (109),
           fuseFailure (110),
           generatorFailure (111),
           lowBatteryThreshold (112),
           pumpFailure (113),
           rectifierFailure (114),
           rectifierHighVoltage (115),
           rectifierLowFVoltage (116),
           ventilationsSystemFailure (117),
           enclosureDoorOpen (118),
           explosiveGas (119),
           fire (120),
           flood (121),
           highHumidity (122),
           highTemperature (123),
           highWind (124),
           iceBuildUp (125),
           intrusionDetection (126),
           lowFuel (127),
           lowHumidity (128),
           lowCablePressure (129),
           lowTemperature (130),
           lowWater (131),
           smoke (132),
           toxicGas (133),
           coolingSystemFailure (134),
           externalEquipmentFailure (135),
           externalPointFailure (136),
           storageCapacityProblem (151),
           memoryMismatch (152),
           corruptData (153),
           outOfCPUCycles (154),
           sfwrEnvironmentProblem (155),
           sfwrDownloadFailure (156),
           lossOfRealTime (157),
           reinitialized (158),
           applicationSubsystemFailure (159),
           configurationOrCustomisationError (160),
           databaseInconsistency (161),
           fileError (162),
           outOfMemory (163),
           softwareError (164),
           timeoutExpired (165),
           underlayingResourceUnavailable (166),
           versionMismatch (167),
           bandwidthReduced (201),
           congestion (202),
           excessiveErrorRate (203),
           excessiveResponseTime (204),
           excessiveRetransmissionRate (205),
           reducedLoggingCapability (206),
           systemResourcesOverload (207),
           adapterError (500),
           callEstablishmentError (503),
           communicationsProtocolError (504),
           communicationsSubsystemFailure (505),
           cpuCyclesLimitExceeded (509),
           datasetOrModemError (510),
           dTE-DCEInterfaceError (512),
           equipmentMalfunction (514),
           excessiveVibration (515),
           heatingOrVentilationOrCoolingSystemProblem (519),
           humidityUnacceptable (520),
           inputOutputDeviceError (521),
           inputDeviceError (522),
           iANError (523),
           leakDetected (524),
           materialSupplyExhausted (528),
           outputDeviceError (531),
           performanceDegraded (532),
           pressureUnacceptable (534),
           queueSizeExceeded (537),
           resourceAtOrNearingCapacity (541),
           responseTimeExcessive (542),
           retransmissionRateExcessive (543),
           softwareProgramAbnormallyTerminated (545),
           softwareProgramError (546),
           temperatureUnacceptable (548),
           thresholdCrossed (549),
           toxicLeakDetected (551),
           underlyingResourceUnavailable (554),
           authenticationFailure (600),
           breachOfConfidentiality (601),
           cableTamper (602),
           delayedInformation (603),
           denialOfService (604),
           duplicateInformation (605),
           informationMissing (606),
           informationModificationDetected (607),
           informationOutOfSequence (608),
           keyExpired (609),
           nonRepudiationFailure (610),
           outOfHoursActivity (611),
           outOfService (612),
           proceduralError (613),
           unauthorizedAccessAttempt (614),
           unexpectedInformation (615),
           bufferOverUnderFlow (1000),
           realigningFrame (1001),
           loopbackApplied (1002),
           farEndReceiveError (1003),
           farEndBitError (1004),
           signalLabelUnequipped (1005),
           protectionSchemeMismatch (1006),
           protectionschemeSignalFail (1007),
           protectionChannelIdMismatchFail (1008),
           unexpectedSignal (1009),
           testingInProgress (1010),
           thresholdCrossing24H (1011),
           thresholdCrossing15M (1012),
           thresholdCrossingFarEnd24H (1013),
           thresholdCrossingFarEnd15M (1014),
           rxCVThresholdCrossed15M (1015),
           rxCVThresholdCrossed24H (1016),
           rxESThresholdCrossed15M (1017),
           rxESThresholdCrossed24H (1018),
           rxSESThresholdCrossed15M (1019),
           rxSESThresholdCrossed24H (1020),
           rxSEFSThresholdCrossed15M (1021),
           rxSEFSThresholdCrossed24H (1022),
           controlSignalDegraded (1023),
           controlSignalPortFail (1024),
           dataCommsChannelLOS (1025),
           dataCommsChannelDEG (1026),
           dataCommsChannelPortFail (1027),
           signalOutsideVideoQuality (1028),
           pathTraceMisalignment (1029),
           provisioningMismatch (1030),
           portSwitchLossOfTraffic (1031),
           txCVThresholdCrossed-15M (1032),
           txCVThresholdCrossed-24H (1033),
           txESThreshodCrossed-15M (1034),
           txESThreshodCrossed-24H (1035),
           txSESThresholdCrossed-15M (1036),
           txSESThresholdCrossed-24H (1037),
           txUASThresholdCrossed-15M (1038),
           txUASThresholdCrossed-24H (1039),
           rxBCVThresholdCrossed-15M (1040),
           rxBCVThresholdCrossed-24H (1041),
           rxBESThresholdCrossed-15M (1042),
           rxBESThresholdCrossed-24H (1043),
           rxBSESThresholdCrossed-15M (1044),
           rxBSESThresholdCrossed-24H (1045),
           timingRefManualSwitchReq (1046),
           timingRefManualSwitchFail (1047),
           timingRefForcedSwitchReq (1048),
           timingRefForcedSwitchComplete (1049),
           timingRefLockoutReq (1050),
           interRingProtSwFail (1051),
           interRingForcedSwitchActive (1052),
           interRingProtSwitchComp (1053),
           interRingBothFeedsFail (1054),
           interRingPrimaryPathFail (1055),
           interRingSecondaryPathFail (1056),
           interRingLockoutReq (1057),
           interRingManualSwReq (1058),
           lowSignalErrorRate (1059),
           txPPJEThresholdCrossed-15M (1060),
           txPPJEThresholdCrossed-24H (1061),
           txNPJEThresholdCrossed-15M (1062),
           txNPJEThresholdCrossed-24H (1063),
           feCVThresholdCrossed-15M (1064),
           feCVThresholdCrossed-24H (1065),
           feESThresholdCrossed-15M (1066),
           feESThresholdCrossed-24H (1067),
           feSESThresholdCrossed-15M (1068),
           feSESThresholdCrossed-24H (1069),
           feUASThresholdCrossed-24H (1070),
           timingRefSwitchFail (1073),
           ringProtSwitchFail (1074),
           ringProtSwitchActive (1075),
           ringLockoutActive (1076),
           ringForcedSwitchActive (1077),
           ringManualSwitchActive (1078),
           ringProtPathFail (1079),
           rxUASThresholdCrossed-15M (1080),
           rxUASThresholdCrossed-24H (1081),
           rxFECThresholdCrossed-15M (1082),
           rxFECThresholdCrossed-24H (1083),
           opticalRxPowerThresholdCrossed (1084),
           laserBiasCurrentThresholdCrossed (1085),
           opticalTxPowerThresholdCrossed (1086),
           lanConnectionLOS (1087),
           protectionSchemeSignalDefault (1088),
           ringProtectionSwitchComplete (1089),
           neighbourProtSchemeInvalid (1090),
           inter-ringConnectionMismatch (1091),
           portSwitchMessageSuppressed (1092),
           line-sectionThresholdCrossed-1M (1093),
           line-sectionThresholdCrossed-15M (1094),
           line-sectionThresholdCrossed-24H (1095),
           pathThresholdCrossed-15M (1096),
           pathThresholdCrossed-24H (1097),
           opticalPowerThresholdCrossed (1098),
           spanProtSwitchFail (1099),
           spanProtSwitchReq (1100),
           spanLockoutActive (1101),
           spanForcedSwitchActive (1102),
           spanManualSwitchActive (1103),
           spanProtPathFail (1104),
           spanProtSwitchComplete (1105),
           feUASThresholdCrossed-15M (1106),
           opticalPowerOutsideLimit (2000),
           degradedLaserPerformance (2001),
           laserShutdown (2002),
           laserShutdownDisabled (2003),
           laserTempOutsideLimit (2004),
           laserTest (2005),
           equipCommsFail (2006),
           lossOfControlSignal (2007),
           backPlaneConfigMismatch (2008),
           nPlusOneProtSwitchComplete (2009),
           syncSelectionProblem (2010),
           primarySyncRefFail (2011),
           syncExternalLos (2012),
           syncUnexpectedSignal (2013),
           timingRefHoldoverMode (2014),
           syncFrequencyOOL (2015),
           syncOscillationFail (2016),
           syncUnreliableTrib (2017),
           mfsPulseFail (2018),
           lanConnectionFail (2019),
           accessEnableVolatileRAM (2020),
           clockLossOneSec (2021),
           detachedNE (2022),
           duplicateNeName (2023),
           duplicateNeNumber (2024),
           hardwarePortFailure (2025),
           secondarySyncRefFail (2026),
           interfaceCardMissing (2027),
           synchronizationInProgress (2028),
           upgradeDowngradeInProgress (2029),
           circuitPackReset (2030),
           equipmentForcedSwitchActive (2031),
           equipmentManualSwitchReq (2032),
           equipmentLockoutReq (2033),
           equipmentProtSwitchComplete (2034),
           equipmentProtSwitchFail (2035),
           au4ParityError (2036),
           extraTrafficEnabled (2037),
           controlSignalHardwarePortFail (2039),
           sdhDCCLOS (2041),
           sdhCCDeg (2042),
           sdhDccprovisioningIncorrect (2043),
           sdhDcchardwareFail (2044),
           intercardDatalinkFail (2045),
           intercardClockFail (2046),
           intercardControlLinkFail (2047),
           equipmentClockLoss (2048),
           lanHardwarePortFail (2049),
           lanProvisioningMismatch (2050),
           protSwitchLossOfTraffic (2051),
           lanConnectionDegraded (2052),
           serialOverheadLinkFail (2053),
           testAlarm (2054),
           lossOfExtraTraffic (2055),
           secondarySyncRefDeg (2057),
           primaryTimingRefDeg (2058),
           maintenanceBusAccessFail (2059),
           linearToRingUpgradeFail (2060),
           hardwareReset (2061),
           timingRefFreerunMode (2062),
           opticalParityError (2063),
           lockoutProtectionFail (2064),
           timingRefAquireMode (2065),
           intercardLinkFail (2066),
           continuousSwitchToggling (2067),
           systemInRecoveryMode (2068),
           protectionOscillationControlActivated (2069),
           circuitPackUnseated (2070),
           elementControllerAlarmsActive (2071),
           timingRefNormalMode (2072),
           maxNeNumExceeded (2073),
           ramFailure (3000),
           softwareCorrupt (3001),
           configDataBankCorrupt (3002),
           configSwVersionMismatch (3003),
           configStandbySwUnstable (3004),
           configFlashMemoryCorrupt (3005),
           writeJumperFitted (3006),
           invalidNeighbour (3007),
           protschemeMismatch (3009),
           protExerciserFail (3010),
           ne-Insecure (4000),
           diskCapacityReached75Percent (5000),
           diskCapacityReached90Percent (5001),
           loginFailAlarm (5002),
           commsFailAlarm (5003),
           alarmsBufferOverflow (5004),
           unprovisionedNEs (5005),
           linkFail (6000),
           linkEndEndMismatch (6001),
           lossOfAlignment (6002),
           squelch (6003),
           txAis (6004),
           bandwidthIncompatible (6005),
           loopbackTerminal (6009),
           insufficientLinkCapacity (6010),
           protectionSwitchComplete (6020),
           manualProtectionSwitchActive (6021),
           lockoutOfProtectionActive (6022),
           forcedProtectionSwitchActive (6023),
           protectionSwitchFail (6024),
           protectionExercisorComplete (6025),
           autoProtectionSwitchAcknowledgeTimeOut (6026),
           protectionByteFail (6027),
           protectionModeMismatch (6028),
           autoProtectionSwitchActive-Path (6029),
           operatorProtectionSwitchActive-Line (6030),
           autoProtectionSwitchActive-Line (6031),
           operatorProtectionSwitchActive-Path (6032),
           timingGenerationSwitchFail (6039),
           timingGenerationLossOfReference (6040),
           timingGenerationDegradedSSM (6041),
           timingGenerationForcedSwitch (6042),
           timingGenerationLockout (6043),
           timingGenerationQlChanged (6044),
           timingGenerationEntryToFreerun (6045),
           timingGenerationFailureToLock (6046),
           timingGenerationEntryToHoldover (6047),
           timingGenerationReferenceSwitchComplete (6048),
           timingDistributionLossOfReference (6049),
           timingDistributionDegradedSSM (6050),
           timingDistributionForcedSwitch (6051),
           timingDistributionLockout (6052),
           timingDistributionQlChanged (6053),
           timingSyncHwFault (6055),
           timingSyncHwAutoSwitchComplete (6056),
           passwordExpiryWarning (6060),
           databaseRestoreInProgress (6073),
           databaseRestoreFailed (6074),
           databaseSaveInProgress (6075),
           timeOfDayProtocolFail (6077),
           lineDCCPortFail (6080),
           sectionDCCPortFail (6081),
           primarySecurityServerUnavailable (6083),
           secondarySecurityServerUnavailable (6084),
           noSecurityServerAvailable (6085),
           engineOperating (6086),
           highWater (6087),
           thresholdCrossingT1 (6088),
           thresholdCrossingT2 (6089),
           timingGenerationDegradedSignal (6090),
           timingGenerationInvalidSSM (6091),
           timingGenerationUnstableSSM (6092),
           txDegradedSignal (6093),
           serviceAffectingRDI (6094),
           batteryFailureA (6101),
           batteryFailureA1 (6102),
           batteryFailureA2 (6103),
           batteryFailureA3 (6104),
           batteryFailureA4 (6105),
           batteryFailureA5 (6106),
           batteryFailureB (6107),
           batteryFailureB1 (6108),
           batteryFailureB2 (6109),
           batteryFailureB3 (6110),
           batteryFailureB4 (6111),
           batteryFailureB5 (6112),
           breakerTripped1 (6113),
           breakerTripped2 (6114),
           breakerTripped3 (6115),
           breakerTripped4 (6116),
           breakerTripped5 (6117),
           breakerTripped6 (6118),
           breakerTripped7 (6119),
           breakerTripped8 (6120),
           databaseRebuilt (6122),
           softwareAutoLoad (6123),
           fpgaLoad (6124),
           provisioningDataMissing (6125),
           provisioningDataMismatch (6126),
           blocked (6127),
           routingDisabled (6128),
           callUnrecoverable (6130),
           protectionBusy (6131),
           protectionFail (6132),
           tunnelLossOfSignal (6133),
           serverUnreachable (6134),
           serverNotProvisioned (6135),
           rejectDHCPaddr (6136),
           docDomainInvalid (6137),
           topologyReconfigInProgress (6138),
           commandFailed (6139),
           docNotOptimized (6140),
           adjacencyInvalid (6141),
           adjacencyMismatch (6142),
           replaceableUnitFailure (6143),
           tODServerUnavailable (6144),
           duplicateAddress (6145),
           docAddCommandFailed (6146),
           docDeleteCommandFailed (6147),
           docResetCommandFailed (6148),
           docMonitorActionFailed (6149),
           docOptimizeActionFailed (6150),
           reconfigInProgress (6151),
           reversionFail (6152),
           oSPFAreaExceeded (6153),
           packetRateLimitExceeded (6154),
           backwardDefectIndication (6155),
           freqOutOfRange (6157),
           txFreqOutOfRange (6158),
           loopbackFacility (6161),
           replaceableUnitUnknown (6163),
           provisioningIncompatible (6166),
           aDMSingleNode (6168),
           fECProvMismatch (6169),
           lossOfDatabaseRedundancy (6170),
           ringProtExerciserFail (6171),
           slatMode (6172),
           spanProtExerciserFail (6173),
           dCCPortFail (6174),
           provisioningFail (6175),
           testAccessActive (6176),
           cnvMismatch (6177),
           pSMMismatch (6178),
           iOMismatch (6179),
           cnvMissing (6180),
           pSMMissing (6181),
           iOMissing (6182),
           cnvUnknown (6183),
           pSMUnknown (6184),
           iOUnknown (6185),
           lossOfDatabase (6186),
           breakerTripped (6190),
           noPower (6192),
           restart (6193),
           replaceableUnitInserted (6194),
           authenticationSuccess (6195),
           userLogout (6196),
           bandwidthThresholdCrossed (6197),
           equipOOSIS (6198),
           craftSwMissing  (6199),
           inconsistentSequenceNumberLCAS (6200),
           memberExcessDifferentialDelayLCAS (6201),
           txPartialLossOfCapacityLCAS (6202),
           txTotalLossOfCapacityLCAS (6203),
           partialLossOfCapacityLCAS (6204),
           totalLossOfCapacityLCAS (6205),
           cRCErrorLCAS (6206),
           unexpectedMemberStatusLCAS (6207),
           statusMismatchLCAS (6208),
           diskCapacityReached100Percent (6209),
           protectionIdMismatch (6210),
           lineProtSwitchFail (6211),
           dataSyncLOS (6212),
           protectionIdMissing (6213),
           mateMismatch (6214),
           intManagmentCommsSuspected (6215),
           lockoutOfWorkingActive (6216),
           softwareMissing (6217),
           secondarySETSLockingToPrimary (6218),
           tODSynchronizationFail (6219),
           tODServerNoResponse (6220),
           replaceableUnitUnexpected  (6221),
           operationsProcessorAlarms  (6222),
           tunUnrecoverable (6223),
           testSignal (6224),
           testSignalOutOfSync (6225),
           testSignalErrorReceived (6226),
           excessivePointerAdjustments (6227),
           txLOS (6228),
           dCCnetworkAccessViolation (6229),
           channelPropagationFail (6230),
           channelPropagationMismatch (6231),
           powerPropagationFail (6232),
           shutdownInProgress (6233),
           frameFormatMismatch (6234),
           idleSignalDetected (6235),
           yellowSignalReceived (6236),
           connectionMismatch (6237),
           oAMNotAvailable (6238),
           databaseSaveRestoreDisabled (6239),
           databaseSaveFailed (6240),
           connectionsDisowned (6241),
           bandwidthStranded (6242),
           coldRestartRequired (6243),
           pmFTPComplete (6244),
           pmFTPFailed (6245),
           pmFTPInProgress (6246),
           replaceableUnitMinorMismatch (6247),
           farEndSignalMismatch (6248),
           channelMonitorCountThreshold (6249),
           lowOrderBandwidthThresholdCrossed  (6250),
           replaceableUnitIncompatible (6251),
           trControlInitInProgress (6252),
           trControlISOptInProgress (6253),
           trControlEchoTraceMismatch (6254),
           trControlDisabled (6255),
           txTuningInProgress (6256),
           bdi (6257),
           rxPowerOutOfRange (6258),
           gcc0LinkFail (6259),
           localFault (6260),
           remoteFault (6261),
           txTotalLossOfCapacity (6262),
           rxTotalLossOfCapacity (6263),
           protectionLocked (6264),
           payloadFail (6265),
           txPayloadFail (6266),
           payloadConsequentFail (6267),
           txPayloadConsequentFail (6268),
           alarmEventThrottlingActive (6269),
           pmTCAThrottlingActive (6270),
           farEndClientRxSignalFailure (6271),
           remotePowerFail (6272),
           farEndClientLinkDown (6273),
           remoteCriticalEvent (6274),
           remoteLoopbackActive (6275),
           remoteLoopbackFail (6276),
           subtendedUnitDiscoveryFail (6277),
           adjacencyProvError (6278),
           docChannelMismatch (6279),
           lossControllerFail (6280),
           duplicatePrimaryInfo (6281),
           duplicateMemberInfo (6282),
           primaryUnreachable (6283),
           memberUnreachable (6284),
           memberMismatch (6285),
           memberUnknown (6286),
           memberCommsFail (6287),
           memberCommsUp (6288),
           memberTL1Fail (6289),
           memberTL1Up (6290),
           serverUnavailable (6291),
           testAccessInProgressMonitorE (6292),
           testAccessInProgressMonitorF (6293),
           testAccessInProgressMonitorEF (6294),
           testAccessInProgressSplitA (6295),
           testAccessInProgressSplitB (6296),
           testAccessInProgressSplitE (6297),
           testAccessInProgressSplitF (6298),
           testAccessInProgressSplitEF (6299),
           ioModuleMismatch (6300),
           ioModuleMissing (6301),
           ioModuleUnknown (6302),
           ringFailure (6303),
           ringletFailure (6304),
           maxNodeExceeded (6305),
           topologyFailure (6306),
           topologyInstability (6307),
           isolatedStation (6308),
           npuLockup (6309),
           bandwidthNotFullyProtected (6310),
           unreachableStation (6311),
           manualAreaAddressDropped (6312),
           maxLevel1NEsExceeded (6313),
           remoteInvalidConfiguration (6314),
           manprovRequired (6315),
           tuningInProgress (6316),
           rxIdle (6317),
           gfpExtendedHdrMismatch (6318),
           autoNegFailed (6319),
           lossOfLCASCapability (6320),
           mismatchFirmwareSoftware (6321),
           docVersionMismatch (6322),
           linkIntegrity (6323),
           gcc1LinkFail (6324),
           gcc2LinkFail (6325),
           docDetectedFault  (6326),
           docConsecutiveReoptimizations  (6327),
           docChAddInProgress  (6328),
           docChDelInProgress  (6329),
           wlMeasWarning  (6330),
           wlMeasError  (6331),
           measuredLossDiscrepancy  (6332),
           docChAddCompleted (6333),
           docChDelCompleted (6334),
           docPreChkPass (6335),
           docPreChkFail (6336),
           docRstTcaComp (6337),
           groupIdentifierMismatchLCAS (6338),
           saveReleaseInProgress (6339),
           fiberTypeUnknown (6340),
           globalSynchronizationPulseInProgress (6341),
           reconfigFailed (6342),
           sumPayloadProtectionSwitchComplete (6343),
           shelfTraceMismatch (6344),
           unpairedSSHKey (6345),
           fDBMACThresholdCrossed (6346),
           fDBMACFlapping (6347),
           ipSecErrorThresholdCrossed (6348),
           ikeErrorThresholdCrossed (6349),
           autoShutoffDisabled (6350),
           lockedMaintenanceSignal (6351),
           openConnectionIndication (6352),
           databaseSyncFailed (6353),
           lanOSPFFail (6354),
           oscOSPFFail (6355),
           adjacencyUnreliable (6356),
           databaseSyncInProgress (6357),
           docRstTcaFail(6358),
           multiplexedRateMismatch(6359),
           dccOSPFFail(6360),
           gccOSPFFail(6361),
           releaseSyncInProgress(6362),
           releaseSyncFailed(6363),
           logCollectionInProgress (6364),
           natTcpConnectionLimitExceeded (6365),
           natUdpConnectionLimitExceeded (6366),
           equipmentSpecificationsExceeded (6367),
           lacpFailed (6369),
           vTSTSBandwidthThresholdCrossed (6370),
           duplicateAdjacency (6371),
           cardSpecificDataUnavailable (6372),
           remotePortOOS (6373),
           rolloverInProgress (6374),
           remoteReplaceableUnitMissing (6375),
           remoteReplaceableUnitTypeMismatch (6376),
           remoteReplaceableUnitProblem (6377),
           remoteOpticalRxPowerThresholdCrossed (6378),
           remoteReinitialized (6379),
           laserTECCurrentHighThresholdCrossed (6380),
           laserTECCurrentLowThresholdCrossed (6381),
           wlMeasHighThresholdCrossed  (6382),
           wlMeasLowThresholdCrossed (6383),
           replaceableUnitRemoved  (6384),
           routingTableThresholdCrossed  (6385),
           debugPortInUse (6386),
           ringAPSTimeOut (6387),
           invalidLicense (6388),
           temporaryLicense (6389),
           cfmLossOfContinuity (6390),
           cfmUnexpectedMAID (6391),
           cfmUnexpectedMEPID (6392),
           cfmUnexpectedPeriod (6393),
           cfmLoopDetection (6394),
           cfmRDI (6395),
           portMirroring (6396),
           cciSessionFail (6397),
           ospfFail (6398),
           rsvpFail (6399),
           cpsCallCreateFailed (6400),
           cpsCallFailed (6401),
           cpsConFailed (6402),
           ethernetRingProtectionEastStatus (6405),
           ethernetRingProtectionWestStatus (6406),
           ethernetRingProtectionRingletStatus (6407),
           topologyChangeDetected (6408),
           cpu2Unreachable (6409),
           docDisabled(6410),
           ccmError (6411),
           macStatusError (6412),
           cpsLocked (6413),
           cciSessionOutOfSync (6414),
           loopbackTraffic  (6415),
           databaseCommitFailed (6416),
           disownFailure (6417),
           takeoverFailure (6418),
           callSegFailure (6419),
           callSegRestoration (6420),
           callSegRestorationFailure (6421),
           callSegLockoutOfRestoration (6422),
           callSegLockoutOfRestorationFailure (6423),
           callSegUnrecoverable (6424),
           reconfigRequired (6425),
           delayMeasurementError (6426),
           warmRestartRequired (6427),
           manuallyDisabled (6428),
           docFailed (6430),
           auditStarted (6431),
           auditComplete (6432),
           auditFailed (6433),
           serviceFail (6434),
           ftpFailed (6435),
           ftpCompleted (6436),
           traceFailed (6437),
           routingBlocked (6438),
           pathMissing (6439),
           bandwidthLocked (6440),
           oscillatingFault (6441),
           hardwareTamper (6443),
           autoConnValidationDisabled (6444),
           reversionInhibited (6445),
           reversionfailed (6446),
           trafficRestore (6447),
           encryptionFailure (6448),
           txPowerReductionState (6449),
           channelContention (6450),
           lossOfControlInfrastructure (7008),
           oscSLDDAdjFail (7009),
           lanSLDDAdjFail (7010),
           certificateExpired (7011),
           certificateAboutToExpire (7012),
           lanOSPFNetAreaDown (7013),
           oscOSPFNetAreaDown (7014),
           gccOSPFNetAreaDown (7015),
           lanOSPFNetAreaUp (7017),
           oscOSPFNetAreaUp (7018),
           gccOSPFNetAreaUp (7019),
           timingGenerationManualSwitch (7021),
           timingDistributionManualSwitch (7022),
           lossSyncMessageChannel (7023),
           laserFreqOutOfRange (7024),
           skewOutOfRange (7025),
           deskewFailure (7026),
           lossOfAlignmentMarker (7027),
           lossOfOPUMultiframIdent (7028),
           timeOfDayNotSynchronized (7029),
           equipmentPoweredDown (7030)
          }

ResourceId ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
         "Resource Identifier"
    SYNTAX       OBJECT IDENTIFIER 

-- Ciena OME6500 Extended Active Alarm Table

ome6500ExtAlarmActiveTable OBJECT-TYPE
  SYNTAX      SEQUENCE OF Ome6500ExtAlarmActiveEntry
  MAX-ACCESS  not-accessible
  STATUS      current
  DESCRIPTION
       "Ciena OME6500 Active Alarm Table Extension"
  ::= { ome6500ExtAlarmObjects 1 }

ome6500ExtAlarmActiveEntry OBJECT-TYPE
  SYNTAX      Ome6500ExtAlarmActiveEntry
  MAX-ACCESS  not-accessible
  STATUS      current
  DESCRIPTION
       "Ciena OME6500 Active Alarm Table Extension Entry"
--  AUGMENTS { alarmActiveEntry }
  INDEX { ome6500ExtAlarmActiveEventType }
  ::= { ome6500ExtAlarmActiveTable 1 }

Ome6500ExtAlarmActiveEntry ::= SEQUENCE {
  ome6500ExtAlarmActiveEventType                     Ome6500ExtAlarmEventType,
  ome6500ExtAlarmActiveProbableCause                 Ome6500ExtAlarmProbableCause,
  ome6500ExtAlarmActiveAdditionalText                SnmpAdminString,
  ome6500ExtAlarmActiveDocumentationPointer          SnmpAdminString,
  ome6500ExtAlarmActiveResourceDescription           SnmpAdminString,
  ome6500ExtAlarmActiveManualClear                   INTEGER,
  ome6500ExtAlarmActiveSequenceNumber                Integer32
  }
  

ome6500ExtAlarmActiveEventType OBJECT-TYPE
  SYNTAX       Ome6500ExtAlarmEventType
  MAX-ACCESS   read-write
  STATUS       current
  DESCRIPTION
        "Ciena OME6500 Active Alarm Table Extension Event Type"
  ::= { ome6500ExtAlarmActiveEntry 1 }


ome6500ExtAlarmActiveProbableCause OBJECT-TYPE
  SYNTAX       Ome6500ExtAlarmProbableCause
  MAX-ACCESS   read-write
  STATUS       current
  DESCRIPTION
        "Ciena OME6500 Active Alarm Table Extension Probable Cause"
  ::= { ome6500ExtAlarmActiveEntry 2 }

ome6500ExtAlarmActiveAdditionalText OBJECT-TYPE
  SYNTAX       SnmpAdminString
  MAX-ACCESS   read-write
  STATUS       current
  DESCRIPTION
        "Ciena OME6500 Active Alarm Table Extension Additional Text"
  ::= { ome6500ExtAlarmActiveEntry 3 }

ome6500ExtAlarmActiveDocumentationPointer OBJECT-TYPE
  SYNTAX       SnmpAdminString
  MAX-ACCESS   read-only
  STATUS       current
  DESCRIPTION
        "Ciena OME6500 Active Alarm Table Extension Documentation Pointer"
  ::= { ome6500ExtAlarmActiveEntry 4 }

ome6500ExtAlarmActiveResourceDescription OBJECT-TYPE
  SYNTAX       SnmpAdminString
  MAX-ACCESS   read-only
  STATUS       current
  DESCRIPTION
        "Ciena OME6500 Active Alarm Table Extension Resource Description"
  ::= { ome6500ExtAlarmActiveEntry 5 }

ome6500ExtAlarmActiveManualClear OBJECT-TYPE
  SYNTAX       INTEGER  {
                        other (1),
                        forbidden (2),
                        required (3),
                        optional (4)
                        }
  MAX-ACCESS   read-only
  STATUS       current
  DESCRIPTION
        "Ciena OME6500 Active Alarm Table Extension Manual Clear Indicator"
  ::= { ome6500ExtAlarmActiveEntry 6 }

ome6500ExtAlarmActiveSequenceNumber OBJECT-TYPE
  SYNTAX       Integer32
  MAX-ACCESS   read-only
  STATUS       current
  DESCRIPTION
        "Ciena OME6500 Active Alarm Table Extension Sequence Number"
  DEFVAL  { 0 }
  ::= { ome6500ExtAlarmActiveEntry 7 }

-- Definition Objects from Active Alarm Table in ALARM-MIB

ome6500AlarmActiveResourceId OBJECT-TYPE
  SYNTAX       INTEGER (0..65535)
  MAX-ACCESS   read-only
  STATUS       current
  DESCRIPTION
        "Ciena OME6500 Alarm Active Resource Id"
  ::= { ome6500AlarmObjects 1 }

ome6500AlarmActiveDateAndTime OBJECT-TYPE
  SYNTAX       DateAndTime
  MAX-ACCESS   not-accessible
  STATUS       current
  DESCRIPTION
        "Ciena OME6500 Alarm Active Date & Time"
  ::= { ome6500AlarmObjects 2 }

ome6500AlarmActiveDescription OBJECT-TYPE
  SYNTAX       SnmpAdminString
  MAX-ACCESS   read-only
  STATUS       current
  DESCRIPTION
           "Ciena OME6500 Alarm Active Description"
  ::= { ome6500AlarmObjects 3 }


ome6500ExtNotificationPrefix OBJECT-IDENTITY
  STATUS       current
  DESCRIPTION
        "Ciena OME6500 NE alarm notifications prefix"
  ::= { ome6500ExtAlarmObjects 0 }

  -- Table of Information related to Messages
  
     ome6500ExtAlarmMessageTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF Ome6500ExtAlarmMessageEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "A table of information on messages. Entries are
          added to this table when their corresponding 
          notifications have been sent. Entires will be
          removed from this table as outlined in the
          Notification Log MIB [RFC3014]. Implementations
          that do not support the Notification Log MIB should
          provide behaviour for nlmLogName, nlmLogIndex and
          this table as if they did."
      ::= { ome6500ExtAlarmObjects 3 }

  ome6500ExtAlarmMessageEntry OBJECT-TYPE
      SYNTAX      Ome6500ExtAlarmMessageEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "An alarm message entry."               
      INDEX       { nlmLogName, nlmLogIndex }
      ::= { ome6500ExtAlarmMessageTable 1 } 
      
   Ome6500ExtAlarmMessageEntry ::= SEQUENCE {   
       ome6500ExtAlarmMessageResource             ResourceId, 
       ome6500ExtAlarmMessageResourceDescription  SnmpAdminString,
       ome6500ExtAlarmMessageDateAndTime          DateAndTime,      
       ome6500ExtAlarmMessageDocumentationPointer SnmpAdminString,
       ome6500ExtAlarmMessageInfo                 SnmpAdminString
    }        
    
    ome6500ExtAlarmMessageResource    OBJECT-TYPE
      SYNTAX      ResourceId
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "This object identifies the resource that this message pertains to

         If there is no corresponding resource, then
         the value of this object MUST be 0.0."
      ::= { ome6500ExtAlarmMessageEntry 1 }    
      
     ome6500ExtAlarmMessageResourceDescription OBJECT-TYPE
      SYNTAX      SnmpAdminString
      MAX-ACCESS  read-only
      STATUS       current
      DESCRIPTION
           "This is a textual description of the resource this message
           pertains to.
                          
            The format of the string is as follows:
		       NEtype=NEname;componentType=componentInstanceId;subcompType=subcompInstanceId;....

 	        With NE as the root, the entire containment with the list of Relative 
 	        Distinguished Names (RDNs) is presented upto the 
            point where the messaging component is clearly identified. 
            Semicolon is the delimiter between a 'category=value' pair.
            The string can only contain alphanumeric characters and 
            underscores. No commas, spaces, slashes, hyphens, or
            dollar signs are allowed
               "
       ::= { ome6500ExtAlarmMessageEntry 2 }



   ome6500ExtAlarmMessageDateAndTime OBJECT-TYPE
      SYNTAX      DateAndTime
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "The local date and time when the message originated.

          Implementations MUST include the offset from UTC,
          if available.  Implementation in environments in which
          the UTC offset is not available is NOT RECOMMENDED."
      ::= { ome6500ExtAlarmMessageEntry 3 }

    ome6500ExtAlarmMessageDocumentationPointer OBJECT-TYPE
      SYNTAX      SnmpAdminString
      MAX-ACCESS  read-only
      STATUS       current
      DESCRIPTION
               "This object servces as a pointer to documentation related to this
               problem.
               
               If there is no specific document pointer for this alarm, this object
               is a null length string."
       ::= { ome6500ExtAlarmMessageEntry 4 }
    
   ome6500ExtAlarmMessageInfo OBJECT-TYPE
    SYNTAX      SnmpAdminString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "A textual discription of the event that has occurred,
            suitable to display to an operator. "
    ::= { ome6500ExtAlarmMessageEntry 5 }
          
    
  -- all notification OIDs would be prefixed with a zero OID to 
  -- facilitate  snmp v1<->v2 conversion

-- Alarm Notifications

        ome6500ExtAlarmClear NOTIFICATION-TYPE
                        OBJECTS { ome6500AlarmActiveResourceId,
                                  ome6500AlarmActiveDateAndTime,
                                  ome6500AlarmActiveDescription,
                                  ome6500ExtAlarmActiveEventType,
                                  ome6500ExtAlarmActiveProbableCause,
                                  ome6500ExtAlarmActiveAdditionalText,
                                  ome6500ExtAlarmActiveDocumentationPointer,
                                  ome6500ExtAlarmActiveResourceDescription,
                                  ome6500ExtAlarmActiveSequenceNumber
                                 }
           STATUS current
           DESCRIPTION
             "Ciena OME6500 notification for an NE alarm clearing"
        
           ::= { ome6500ExtNotificationPrefix 301 }


        ome6500ExtAlarmWarning NOTIFICATION-TYPE
                        OBJECTS { ome6500AlarmActiveResourceId,
                                  ome6500AlarmActiveDateAndTime,
                                  ome6500AlarmActiveDescription,
                                  ome6500ExtAlarmActiveEventType,
                                  ome6500ExtAlarmActiveProbableCause,
                                  ome6500ExtAlarmActiveAdditionalText,
                                  ome6500ExtAlarmActiveDocumentationPointer,
                                  ome6500ExtAlarmActiveResourceDescription,
                                  ome6500ExtAlarmActiveManualClear,
                                  ome6500ExtAlarmActiveSequenceNumber
                                 }
           STATUS current
           DESCRIPTION
             "Ciena OME6500 notification for an NE alarm of warning severity"
        
           ::= { ome6500ExtNotificationPrefix 302 }


        ome6500ExtAlarmMinor NOTIFICATION-TYPE
                        OBJECTS { ome6500AlarmActiveResourceId,
                                  ome6500AlarmActiveDateAndTime,
                                  ome6500AlarmActiveDescription,
                                  ome6500ExtAlarmActiveEventType,
                                  ome6500ExtAlarmActiveProbableCause,
                                  ome6500ExtAlarmActiveAdditionalText,
                                  ome6500ExtAlarmActiveDocumentationPointer,
                                  ome6500ExtAlarmActiveResourceDescription,
                                  ome6500ExtAlarmActiveManualClear,
                                  ome6500ExtAlarmActiveSequenceNumber
                                 }
           STATUS current
           DESCRIPTION
             "Ciena OME6500 notification for an NE alarm of minor severity"
        
           ::= { ome6500ExtNotificationPrefix 303 }


        ome6500ExtAlarmMajor NOTIFICATION-TYPE
                        OBJECTS { ome6500AlarmActiveResourceId,
                                  ome6500AlarmActiveDateAndTime,
                                  ome6500AlarmActiveDescription,
                                  ome6500ExtAlarmActiveEventType,
                                  ome6500ExtAlarmActiveProbableCause,
                                  ome6500ExtAlarmActiveAdditionalText,
                                  ome6500ExtAlarmActiveDocumentationPointer,
                                  ome6500ExtAlarmActiveResourceDescription,
                                  ome6500ExtAlarmActiveManualClear,
                                  ome6500ExtAlarmActiveSequenceNumber
                                 }
           STATUS current
           DESCRIPTION
             "Ciena OME6500 notification for an NE alarm of major severity"
        
           ::= { ome6500ExtNotificationPrefix 304 }


        ome6500ExtAlarmCritical NOTIFICATION-TYPE
                        OBJECTS { ome6500AlarmActiveResourceId,
                                  ome6500AlarmActiveDateAndTime,
                                  ome6500AlarmActiveDescription,
                                  ome6500ExtAlarmActiveEventType,
                                  ome6500ExtAlarmActiveProbableCause,
                                  ome6500ExtAlarmActiveAdditionalText,
                                  ome6500ExtAlarmActiveDocumentationPointer,
                                  ome6500ExtAlarmActiveResourceDescription,
                                  ome6500ExtAlarmActiveManualClear,
                                  ome6500ExtAlarmActiveSequenceNumber
                                 }
           STATUS current
           DESCRIPTION
             "Ciena OME6500 notification for an NE alarm of critical severity"
           ::= { ome6500ExtNotificationPrefix 305 }

        ome6500ExtAlarmMessage NOTIFICATION-TYPE
                        OBJECTS { ome6500ExtAlarmMessageResource, 
                                  ome6500ExtAlarmMessageResourceDescription, 
                                  ome6500ExtAlarmMessageDateAndTime,
                                  ome6500ExtAlarmMessageDocumentationPointer,
                                  ome6500ExtAlarmMessageInfo                  
                                  }
          STATUS  current
          DESCRIPTION
            "An informational message. This notification does not
            correspond to an alarm so would not be stored in the
            active alarm table and it does not have a corresponing
            clear."
           ::= { ome6500ExtNotificationPrefix 306 }


END