AVAYA-RTP-MIB DEFINITIONS ::= BEGIN
   IMPORTS
     OBJECT-GROUP, NOTIFICATION-GROUP, MODULE-COMPLIANCE
         FROM SNMPv2-CONF
     Integer32, Unsigned32, enterprises, Gauge32, Counter32, OBJECT-TYPE, 
      MODULE-IDENTITY, NOTIFICATION-TYPE
         FROM SNMPv2-SMI
      RowStatus, TEXTUAL-CONVENTION, TruthValue, DateAndTime, TimeInterval, DisplayString
         FROM SNMPv2-TC      
       InetAddressType, InetAddress, InetPortNumber, InetAddressIPv6
         FROM INET-ADDRESS-MIB
       IpAddress
         FROM RFC1155-SMI;
      


     avRtpMib MODULE-IDENTITY
       LAST-UPDATED "201501091031Z"   
     ORGANIZATION
                       "Avaya"
     CONTACT-INFO
     "
       Avaya Customer Services
       Postal: Avaya, Inc.
       211 Mt Airy Rd.
       Basking Ridge, NJ 07920
       USA
       Tel:	+1 908 953 6000
       WWW: 	http://www.avaya.com
     "
     DESCRIPTION
     "              
     This module defines an interface to RTP sessions QoS statistic gathering capabilities 
     in Avaya's VoIP enabled devices. The MIB, designed for Avaya Services, allows operators
      to perform the following tasks:
        1.	View the statistics of recently terminated RTP session. 
        2.	Define QoS related thresholds that define bad-QoS conditions.
        3.	View the statistics of last session, which experienced bad QoS.
        4.	Enable a special QoS trap that is sent upon termination of RTP session with bad QoS. 
        5.	Enable a special QoS fault trap that is sent when more than N streams suffer from bad QoS. And a QoS clear trap that is sent when this fault conditions ends.
        6.	Configure the above traps rate limiting mechanism.

     Copyright notice:
     
     This AVAYA SNMP Management Information Base Specification (Specification) embodies
     AVAYA confidential and Proprietary intellectual property.  AVAYA retains all Title
     and ownership in the Specification, including any revisionsIt is AVAYA's intent to
     encourage the widespread use of this Specification in connection with the management
     of AVAYA products. AVAYA grants vendors, end-users, and other interested parties a
     non-exclusive license to use this Specification in connection with the management 
     of AVAYA products.This Specification is supplied 'as is', and AVAYA makes no warranty,
     either express or implied, as to the use, operation, condition, or performance of the
      Specification.     
     "
--Warning! do not change the token below. Required for parsing.
--ChkTk001 Parsing token 001

           ::= { mibs 7  }  

-- Version 201501091031Z
-- 1. Add Opus to avRtpSessionType
-- 2. Add AES256 to avRtpSessionTxEncryp
           
-- Version 201006081712Z
-- 1. Add avRtpQoSInetTrap.
           
-- Version 200912231042Z
-- 1. Add avRtpSessionTxFlowLabel and avRtpSessionRxFlowLabel
--
-- Version 200612241255Z
--  add "generic" srtp enum to AvRtpSessionTxEncryp 
-- Version 200510061516Z
--  1. Add new enums to avRtpSessionType 
--
-- Version 200505191225Z
--  1. Add enums to AvRtpSessionTxEncryp for SRTP
--
-- Version 200410271525Z
--  1.  Change the avRtpSessionEcReturnLoss range
--  2.  Update description: avRtpSessionCname, avRtpSessionPhone 
--  3.  avRtpSessionTxEncryp  change AEA enum to encryptionAEAv2 
--
-- Version 200410211225Z
--     Update some of the threshold ranges
--
-- Version 200410201417Z
--  1. Add avRtpSessionSeverity to the traps
--  2. Change configuration items to INTEGER with ranges
--  3. Change    avRtpFaultMask SYNTAX to OCTET STRING
--
-- Version 200402080725Z
--   Fix the lookup table: include the sessionID in the index
--
--
-- Version 200401081250Z
--   Simplify the trap rate limiter replace old items with AvrtpQoSTrapTokenInterval
--        and AvrtpQoSTrapBucketSize
--
-- Version 200406221435Z
--   1. Add avRtpFaultMask
--   2. avRtpDateAndTime access changed to read-only
--   3. avRtpSumTable index should be avRtpSumEngineID
--   4. Rename:
--        avRtpSessionTableSize   to avRtpMaxSessionTableSize
--        avRtpSessionTableReservedRows  to avRtpReservedSessionTableRows
--        avRtpSessionClear to 

--
-- Version 200406221507Z
--  avRtpThresholdRxAvgCodecLoss item added
--
-- Version 200404260701Z
--    avRtpSessionPhone syntax changed to DisplayString
--    avRtpavRtpQoSTrapShapeMaxDelay changed to avRtpQoSTrapShapeMaxDelay
--	  avRtpSessionStatInerval changed to avRtpSessionStatInterval 
--
-- Version 200404210955Z
--  change avRtpQoSClearTh syntax to integer32 (typo)
--
-- Version 200403300000Z
--   Modification to allow the MIB to compile with the embedded firmware.
--
-- Version 200403290000Z
--   Update the Session Table to support IPv6, Codec RTT and Codec Loss.
--
-- Version 200402210000Z
--   Initial Version

  AvRtpItuPerceivedSeverity ::= TEXTUAL-CONVENTION
       STATUS current
       DESCRIPTION
               "ITU perceived severity values"
       REFERENCE
              "ITU Recommendation M.3100, 'Generic Network Information
               Model', 1995
               ITU Recommendation X.733, 'Information Technology - Open
               Systems Interconnection - System Management: Alarm
               Reporting Function', 1992"
       SYNTAX         INTEGER
              {
              cleared (1),
              indeterminate (2),
              critical (3),
              major (4),
              minor (5),
              warning (6)
              }     
              
    AvRtpLoss ::= TEXTUAL-CONVENTION          
       DISPLAY-HINT "d-1%"
       STATUS current
       DESCRIPTION
               "Loss in 1/10 precent accuracy"       
       SYNTAX INTEGER (-1..1000)
   
    AvRtpSilenceSupp   ::= TEXTUAL-CONVENTION          
       STATUS current
       DESCRIPTION
               "Silence Suppression modes where:
                noRtp(2)  No RTP packets during silence periods
                SilenceFrames(3)  The codec sends special silence frames during silence periods
                Complex(4)  A combination of the above"       
       SYNTAX INTEGER {
           notSupported (0),
           disabled (1),
           noRtp (2),
           silenceFrames (3),
           complex (4)  }


avaya OBJECT IDENTIFIER ::= { enterprises 6889 }
       
mibs OBJECT IDENTIFIER ::= { avaya 2 }

--Warning! do not change the token below. Required for parsing.
--ChkTk002 Parsing token 002
              
avRtpNotification OBJECT IDENTIFIER ::= { avRtpMib 0 }

	avRtpQoSTrap NOTIFICATION-TYPE
            OBJECTS { avRtpSessionLocAddrV4, avRtpSessionRemAddrV4, avRtpSessionDuration,
                    avRtpSessionCname, avRtpSessionPhone, 
                    avRtpSessionSeverity, avRtpSessionDebugStr }
            STATUS current
            DESCRIPTION
                "The trap contains QoS statistics for a single RTP session.
                 The device can send this trap when an RTP session that experienced bad 
                 QoS terminates"
            ::= { avRtpNotification 1 }

	avRtpQoSFault NOTIFICATION-TYPE
            OBJECTS { avRtpQoSFaultTh, avRtpQoSClearTh, avRtpSessionSeverity }
            STATUS current
            DESCRIPTION
                "The trap indicates that more than XXX RTP sessions currently suffers 
                from bad QoS." 
            ::= { avRtpNotification 2 }
            
	avRtpQoSClear NOTIFICATION-TYPE
            OBJECTS { avRtpQoSFaultTh, avRtpQoSClearTh, avRtpSessionSeverity }
            STATUS current
            DESCRIPTION
                "This trap indicates that a QoS fault, previously indicated by an
                 avRtpQoSFault has cleared. "
            ::= { avRtpNotification 3 }    
            
    avRtpQoSInetTrap NOTIFICATION-TYPE
            OBJECTS { avRtpSessionLocInetAddrType, avRtpSessionLocInetAddr, 
            avRtpSessionRemInetAddrType, avRtpSessionRemInetAddr,
            avRtpSessionDuration, avRtpSessionCname, avRtpSessionPhone, 
                    avRtpSessionSeverity, avRtpSessionDebugStr }
            STATUS current
            DESCRIPTION
                "The trap contains QoS statistics for a single RTP session over IPv4/IPv6.
                 The device can send this trap when an RTP session that experienced bad 
                 QoS terminates"
            ::= { avRtpNotification 4 }
     
            
avRtpConfig OBJECT IDENTIFIER ::= { avRtpMib 1 }
      

avRtpThresholdTable OBJECT-TYPE
	SYNTAX	   SEQUENCE OF AvRtpThresholdEntry
	MAX-ACCESS not-accessible
	STATUS	   current
	DESCRIPTION
	    "Thresholds configuration table"
	::= { avRtpConfig 1 }
	
	avRtpThresholdEntry OBJECT-TYPE
	SYNTAX	   AvRtpThresholdEntry
	MAX-ACCESS not-accessible
	STATUS	   current
	DESCRIPTION
	    "Each entry contains one set of thresholds. In this version only one entry is
	     supported (1). "
	INDEX {
	     avRtpThresholdSet
	}
	::= { avRtpThresholdTable 1 }



    AvRtpThresholdEntry ::= SEQUENCE {
      avRtpThresholdSet Integer32,
      avRtpThresholdMinStatWin INTEGER, 
      avRtpThresholdRxCodecLoss AvRtpLoss, 
      avRtpThresholdRxAvgCodecLoss AvRtpLoss, 
      avRtpThresholdRxCodecLossEv INTEGER,
      avRtpThresholdCodecRtt INTEGER,
      avRtpThresholdCodecRttEv INTEGER,
      avRtpThresholdEcReturnLoss INTEGER,
      avRtpThresholdEcReturnLossEv INTEGER,
      avRtpThresholdRxLoss AvRtpLoss,
      avRtpThresholdRxLossEv INTEGER,
      avRtpThresholdRemLoss AvRtpLoss,
      avRtpThresholdRemLossEv INTEGER,
      avRtpThresholdAvgRxLoss AvRtpLoss,
      avRtpThresholdAvgRemLoss AvRtpLoss,
      avRtpThresholdRxJitter INTEGER,
      avRtpThresholdRxJitterEv INTEGER,
      avRtpThresholdRemJitter INTEGER,
      avRtpThresholdRemJitterEv INTEGER,
      avRtpThresholdRtt INTEGER,
      avRtpThresholdRttEv INTEGER,
      avRtpThresholdRxSsrcChangeEv INTEGER
    }

    avRtpThresholdSet OBJECT-TYPE
            SYNTAX Integer32
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
              "The threshold set"    
            ::= { avRtpThresholdEntry 1 }
	
     avRtpThresholdMinStatWin OBJECT-TYPE
            SYNTAX INTEGER (1..1000)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The minimum number of observed RTP sequence numbers advance needed for the 
                evaluation of packet loss. "
            ::= { avRtpThresholdEntry 2 }

     avRtpThresholdRxCodecLoss OBJECT-TYPE
            SYNTAX AvRtpLoss
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "Codec packet loss i.e. the loss at the codec decoder. This threshold is 
                evaluated once for each statistical interval (6-12 seconds)"
            ::= { avRtpThresholdEntry 3 }

	 avRtpThresholdRxAvgCodecLoss  OBJECT-TYPE
            SYNTAX AvRtpLoss
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "Threshold on the avarage codec loss"
            ::= { avRtpThresholdEntry 4 }
	 
     avRtpThresholdRxCodecLossEv OBJECT-TYPE
            SYNTAX INTEGER (0..1000)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The device generates a QoS traps if avRtpThresholdRxCodecLoss was crossed
                 avRtpThresholdRxCodecLossEv times during the session (0 means that no traps 
                 are sent for this threshold)."
            ::= { avRtpThresholdEntry 5}  

     avRtpThresholdCodecRtt OBJECT-TYPE
            SYNTAX INTEGER (0..5000)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "Codec round trip time threshold (an estimate for the overall RTT, including 
                 the internal delays). This threshold is evaluated each time an RTCP message 
                 is received (usually every 6-12 seconds)"
            ::= { avRtpThresholdEntry 6}

     avRtpThresholdCodecRttEv OBJECT-TYPE
            SYNTAX INTEGER (0..1000)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The device generates a QoS traps if avRtpThresholdCodecRtt was crossed
                 avRtpThresholdCodecRttEv times during the session (0 means that no traps 
                 are sent for this threshold)."
            ::= { avRtpThresholdEntry 7}  

     avRtpThresholdEcReturnLoss OBJECT-TYPE
            SYNTAX INTEGER (0..100)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "Echo Cancellation return loss in -dBm. High value (low absolute)
                 means that a lot of energy is returned which can result in auditable echos.
                 This threshold is evaluated once for each statistical interval (6-12 seconds) "
            ::= { avRtpThresholdEntry 8}

     avRtpThresholdEcReturnLossEv OBJECT-TYPE
            SYNTAX INTEGER (0..1000)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                ""
            ::= { avRtpThresholdEntry 9 }             


     avRtpThresholdRxLoss OBJECT-TYPE
            SYNTAX AvRtpLoss
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The received packet loss.
                 This threshold is evaluated once for each statistical interval (6-12 seconds) "
            ::= { avRtpThresholdEntry 10  }

     avRtpThresholdRxLossEv OBJECT-TYPE
            SYNTAX INTEGER (0..1000)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The device generates a QoS traps if avRtpThresholdRxCodecLoss was crossed
                 avRtpThresholdRxCodecLossEv times during the session (0 means that no traps 
                 are sent for this threshold)."
            ::= { avRtpThresholdEntry 11 } 

     avRtpThresholdRemLoss OBJECT-TYPE
            SYNTAX AvRtpLoss
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "Remote peer packet loss threshold learnt from received RTCP reports.
                 This threshold is evaluated once for each statistical interval (6-12 seconds) "
            ::= { avRtpThresholdEntry 12 }

     avRtpThresholdRemLossEv OBJECT-TYPE
            SYNTAX INTEGER (0..1000)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                ""
            ::= { avRtpThresholdEntry 13 } 

     avRtpThresholdAvgRxLoss OBJECT-TYPE
            SYNTAX AvRtpLoss
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The received average packet loss. This threshold is evaluated at the end
                 of the session."
            ::= { avRtpThresholdEntry 14 }

     avRtpThresholdAvgRemLoss OBJECT-TYPE
            SYNTAX AvRtpLoss
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "Threshold on the  average remote packet loss, learnt from RTCP reports.
                 This threshold is evaluated at the end of the session."
            ::= { avRtpThresholdEntry 15 }

       avRtpThresholdRxJitter OBJECT-TYPE
            SYNTAX INTEGER (0..5000)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "A threshold on the received inter-arrival jitter, measured in milliseconds.
                This threshold is evaluated once for each statistical interval (6-12 seconds)"
            ::= { avRtpThresholdEntry 16 }

     avRtpThresholdRxJitterEv OBJECT-TYPE
            SYNTAX INTEGER (0..1000)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                ""
            ::= { avRtpThresholdEntry 17 }

     avRtpThresholdRemJitter OBJECT-TYPE
            SYNTAX INTEGER (0..5000)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "A threshold on the remote inter-arrival jitter, learnt from RTCP reports.
                 This item is measured in milliseconds and is evaluated upon reception
                  of an RTCP message."
            ::= { avRtpThresholdEntry 18 }

     avRtpThresholdRemJitterEv OBJECT-TYPE
            SYNTAX INTEGER (0..1000)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                ""
            ::= { avRtpThresholdEntry 19 }

     avRtpThresholdRtt OBJECT-TYPE
            SYNTAX INTEGER (0..5000)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "A threshold on the network round-trip-time, measured in milliseconds. 
                  This item is evaluated upon reception of RTCP messages."
            ::= { avRtpThresholdEntry 20 }

     avRtpThresholdRttEv OBJECT-TYPE
            SYNTAX INTEGER (0..1000)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                ""
            ::= { avRtpThresholdEntry 21 }

	avRtpThresholdRxSsrcChangeEv    OBJECT-TYPE
            SYNTAX INTEGER (0..1000)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The device would generate an end-of-session QoS trap if the number of observed 
                SSRC changes was over this treshold."
            ::= { avRtpThresholdEntry 22 }        
            
     


      avRtpEnable OBJECT-TYPE
            SYNTAX TruthValue
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "Enable RTP statistic collection by the device.
                 Note that statistic collection may cause minor performance hit."
            ::= { avRtpConfig 2 }

      avRtpQoSTrapEnable OBJECT-TYPE
            SYNTAX TruthValue
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "EEnable the QoS-Trap generation."
            ::= { avRtpConfig 3 }            
            
      avRtpQoSFaultTrapEnable OBJECT-TYPE
            SYNTAX TruthValue
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "Enable the QoS-Trap generation."
            ::= { avRtpConfig 4 }            
            
      avRtpQoSFaultTh OBJECT-TYPE
            SYNTAX INTEGER (1..100)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The number of concurrent active RTP sessions that suffers from bad QoS
                 (according to avRtpThresholds) that cause the device to enter a 
                 'QoS fault' state. Note, upon entering this fault state, the device sends
                  a avRtpQoSFault trap."
            ::= { avRtpConfig 5 }     
            
	  avRtpQoSClearTh OBJECT-TYPE            
            SYNTAX INTEGER (0..99)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The number of concurrent active RTP sessions that suffers from bad QoS 
                (according to avRtpThresholds) that clears the 'QoS fault' state.
                 Note, when the QoS fault clears, the device send a avRtpQoSClear trap."
            ::= { avRtpConfig 6 }     
            
      avRtpTxQoSTraps OBJECT-TYPE            
            SYNTAX Counter32
            MAX-ACCESS read-only
            STATUS current            
            DESCRIPTION
                "The number of  avRtpQoSTrap  sent so far."
            ::= { avRtpConfig  7}     
            
      avRtpQoSTrapsDrop OBJECT-TYPE            
            SYNTAX Counter32
            MAX-ACCESS read-only
            STATUS current            
            DESCRIPTION
                "The number of avRtpQoSTraps that were dropped by the rate limiter"
            ::= { avRtpConfig  8}     
            
            avRtpQoSTrapTokenInterval OBJECT-TYPE            
            SYNTAX TimeInterval (10..1000000)
            MAX-ACCESS read-write
            STATUS current            
            DESCRIPTION
                "Configure the QoS trap token-bucket rate limiter. This item sets
                 the token interval in hundredth of seconds."
            DEFVAL { 1000 }                
            ::= { avRtpConfig  9}     
            
            avRtpQoSTrapBucketSize OBJECT-TYPE            
            SYNTAX  INTEGER (1..1000)
            MAX-ACCESS read-write
            STATUS current            
            DESCRIPTION
                "Configure the QoS trap token-bucket rate limiter. This item
                 configures the bucket-size."
            DEFVAL { 5 }                 
            ::= { avRtpConfig  10}                 

            
            avRtpDateAndTime OBJECT-TYPE            
            SYNTAX   DateAndTime
            MAX-ACCESS read-only
            STATUS current            
            DESCRIPTION
                "The current RTC date and Time"
            ::= { avRtpConfig 11 }                          

            avRtpMaxSessionTableSize OBJECT-TYPE            
            SYNTAX   Integer32
            MAX-ACCESS read-only
            STATUS current            
            DESCRIPTION
                "The maximum number of rows of the session table"
            ::= { avRtpConfig 12 }        

          avRtpReservedSessionTableRows OBJECT-TYPE            
            SYNTAX   Integer32
            MAX-ACCESS read-only
            STATUS current            
            DESCRIPTION
                "The number of rows in session table reserved for terminated
                 sessions that had QoS events "
            ::= { avRtpConfig 13 }    
           
           avRtpClear OBJECT-TYPE            
            SYNTAX   TruthValue
            MAX-ACCESS read-write
            STATUS current            
            DESCRIPTION
                "Clear the Session table"
            ::= { avRtpConfig 14 } 
            
            avRtpFaultMask OBJECT-TYPE            
            SYNTAX   OCTET STRING (SIZE (0..1))
            MAX-ACCESS read-only
            STATUS current            
            DESCRIPTION
                "Fault mask enables Avaya Fault-Mon to poll the device status
                  Bit 0 - Set if there is a fault condition according to
                          avRtpQoSFaultTh/avRtpQoSClearTh"                          
            ::= { avRtpConfig 15 } 

  avRtpSessionTable OBJECT-TYPE
      SYNTAX SEQUENCE OF AvRtpSessionEntry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
                "This table contains statistics for recently terminated RTP flows."
      ::= { avRtpMib 2 }

      avRtpSessionEntry OBJECT-TYPE
            SYNTAX AvRtpSessionEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "Each row contains information from a single RTP session. 
                 Rows are removed when the space limits are reached (avRtpSessionTableSize).
                 There are avRtpSessionTableReservedRows reserved rows for terminated
                 sessions that had QoS events. Sessions that had QoS events 
                 might appear twice in the table, e.g. once with
                 AvRtpSessionState = terminated and once with 
                 terminatedWithEvent. 
                "
            INDEX { avRtpSessionState, avRtpSessionID }
            ::= { avRtpSessionTable 1 }
        
        AvRtpSessionEntry ::=
            SEQUENCE { 
				avRtpSessionState INTEGER,
				avRtpSessionID Integer32,
				avRtpSessionEngineID Integer32,   
				avRtpSessionLocAddrType InetAddressType,
				avRtpSessionLocAddr InetAddress,   
				avRtpSessionLocAddrV4 IpAddress,
				avRtpSessionLocAddrV6 InetAddressIPv6,
				avRtpSessionRemAddrType InetAddressType,
				avRtpSessionRemAddr InetAddress,     			
				avRtpSessionRemAddrV4 IpAddress,
				avRtpSessionRemAddrV6 InetAddressIPv6,
				avRtpSessionLocPort	InetPortNumber,
				avRtpSessionRemPort	InetPortNumber, 
				avRtpSessionStartTime	DateAndTime,
				avRtpSessionEndTime	DateAndTime,
				avRtpSessionDuration	TimeInterval,				
                avRtpSessionCname  DisplayString,
                avRtpSessionPhone  DisplayString,
                avRtpSessionSeverity INTEGER,
                avRtpSessionTxLen Integer32,
                avRtpSessionType INTEGER,
                avRtpSessionTxInterval Integer32,
                avRtpSessionTxEncryp INTEGER,
                avRtpSessionTxDscp	INTEGER,
                avRtpSessionTxVlan INTEGER,
                avRtpSessionTxL2Pri INTEGER,
                avRtpSessionTxSilenceSupp	AvRtpSilenceSupp,
                avRtpSessionTxSsrc	Unsigned32,
                avRtpSessionTxRsvp INTEGER,
                avRtpSessionTxResvFail	Gauge32,
                avRtpSessionStatInterval	TimeInterval,
                avRtpSessionRxCodecPlayTime Counter32,
                avRtpSessionRxCodecLossCount Counter32,
                avRtpSessionRxCodecLoss AvRtpLoss,
                avRtpSessionRxAvgCodecLoss AvRtpLoss,
                avRtpSessionRxCodecLossEv Counter32, 
                avRtpSessionRxLoss    AvRtpLoss,
                avRtpSessionRxAvgLoss AvRtpLoss,
                avRtpSessionRxLossEv  Counter32,                
				avRtpSessionRx 	Counter32,
				avRtpSessionRxLossCount	Counter32,
				avRtpSessionRxSeqFall	Counter32,
				avRtpSessionRxDup	Counter32,
				avRtpSessionRxJBufUnderruns	Gauge32,
				avRtpSessionRxJBufOverruns	Gauge32,
				avRtpSessionRxJBufDelay	Integer32,
				avRtpSessionRxMaxJBufDelay Integer32,
				avRtpSessionRxJitter Integer32,
				avRtpSessionRxAvgJitter Integer32,
				avRtpSessionRxJitterEv Counter32,			
				avRtpSessionRxTtl	INTEGER,
				avRtpSessionRxMinTtl	INTEGER,
				avRtpSessionRxMaxTtl	INTEGER, 
				avRtpSessionRxDscp	INTEGER,
				avRtpSessionRxL2Pri	INTEGER,
				avRtpSessionRxSilenceSupp	AvRtpSilenceSupp,
				avRtpSessionRxSsrc	Unsigned32,
				avRtpSessionRxSsrcChange Counter32,			
   				avRtpSessionTxRtcp	Counter32,
				avRtpSessionRxRtcp	Counter32,     
				avRtpSessionCodecRtt	Integer32,
				avRtpSessionAvgCodecRtt	Integer32,
				avRtpSessionCodecRttEv	Counter32,				
				avRtpSessionRtt	Integer32,
				avRtpSessionAvgRtt	Integer32,
				avRtpSessionRttEv	Counter32,
				avRtpSessionRemLoss AvRtpLoss,
				avRtpSessionRemAvgLoss  AvRtpLoss,
				avRtpSessionRemLossEv Counter32,
				avRtpSessionRemJitter	Integer32,
				avRtpSessionRemAvgJitter Integer32,
				avRtpSessionRemJitterEv	Counter32,				
				avRtpSessionEcTailLen	Integer32,
				avRtpSessionEcReturnLoss	INTEGER,
				avRtpSessionEcReturnLossEv	Counter32,
				avRtpSessionAEC INTEGER,
				avRtpSessionDebugStr DisplayString,
				avRtpSessionTxFlowLabel	INTEGER,
                avRtpSessionRxFlowLabel	INTEGER
				}

        avRtpSessionState OBJECT-TYPE            
        SYNTAX  INTEGER {active(1), activeWithEvent(2), terminated(3),terminatedWithEvent(4)}
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "An arbitrary RTP-flow sequence number, serves as the MIB tables index"
        ::= { avRtpSessionEntry 1} 

        avRtpSessionID OBJECT-TYPE            
        SYNTAX  Integer32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "An arbitrary RTP-flow sequence number, serves as the MIB tables index"
        ::= { avRtpSessionEntry 2}                 
        
        avRtpSessionEngineID OBJECT-TYPE            
        SYNTAX Integer32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The number of the VoIP engine responsible for the RTP stream.
          More information about the specific VoIP engine can be found in
           avRtpSumTable"
        ::= { avRtpSessionEntry 3}           

  		avRtpSessionLocAddrType OBJECT-TYPE            
         SYNTAX  InetAddressType
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "This item specifies whether the IP addresses in this row are in IPv6
          or in IPv4 format (See RFC3291)"
        ::= { avRtpSessionEntry 4}                  

  		avRtpSessionLocAddr OBJECT-TYPE           
        SYNTAX InetAddress     
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The RTP stream local RTP address."
        ::= { avRtpSessionEntry 5}        
        
    	avRtpSessionLocAddrV4 OBJECT-TYPE           
        SYNTAX IpAddress     
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The RTP stream local RTP address (IPv4)."
        ::= { avRtpSessionEntry 6} 

    	avRtpSessionLocAddrV6 OBJECT-TYPE           
        SYNTAX InetAddressIPv6     
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The RTP stream local RTP address (IPv6)."
        ::= { avRtpSessionEntry 7} 
       

		avRtpSessionRemAddrType OBJECT-TYPE            
        SYNTAX  InetAddressType
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "This item specifies whether the remote IP addresses in this row is in IPv6
          or in IPv4 format (See RFC3291)"
        ::= { avRtpSessionEntry 8}          
        
  		avRtpSessionRemAddr OBJECT-TYPE            
        SYNTAX  InetAddress
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The RTP stream remote peer address"
        ::= { avRtpSessionEntry 9}                  

    	avRtpSessionRemAddrV4 OBJECT-TYPE           
        SYNTAX IpAddress     
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The RTP stream Remote RTP address (IPv4)."
        ::= { avRtpSessionEntry 10} 

    	avRtpSessionRemAddrV6 OBJECT-TYPE           
        SYNTAX InetAddressIPv6     
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The RTP stream Remote RTP address (IPv6)."
        ::= { avRtpSessionEntry 11} 


  		avRtpSessionLocPort OBJECT-TYPE            
        SYNTAX InetPortNumber
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The RTP stream local UDP port"
        ::= { avRtpSessionEntry 12}             
        
       avRtpSessionRemPort OBJECT-TYPE            
        SYNTAX InetPortNumber
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The RTP stream remote UDP port"
        ::= { avRtpSessionEntry 13}                 

  		avRtpSessionStartTime OBJECT-TYPE            
        SYNTAX DateAndTime
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The stream start time"
        ::= { avRtpSessionEntry 14}                 

  		avRtpSessionEndTime OBJECT-TYPE            
        SYNTAX DateAndTime
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The stream end time"
        ::= { avRtpSessionEntry 15}

       avRtpSessionDuration OBJECT-TYPE            
        SYNTAX  TimeInterval
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The duration of the stream in hundredth of seconds"
        ::= { avRtpSessionEntry 16}                 
            

  		avRtpSessionCname OBJECT-TYPE            
        SYNTAX  DisplayString (SIZE (0..100))
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The RTP canonical name of the gateway"
        ::= { avRtpSessionEntry 17} 

        avRtpSessionPhone OBJECT-TYPE            
        SYNTAX DisplayString (SIZE (0..22))
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "A string containing the phone extensions (received for CM), in the format of
          <conferenceID>:<extension #1>...<extension #N>"
        ::= { avRtpSessionEntry 18}                 


  		avRtpSessionSeverity OBJECT-TYPE            
-- Note, the syntax should match up exactly with AvRtpItuPerceivedSeverity.
-- The CGTrap.sh tool does not expect another redirection so hard code
-- the enuerated types to the same as the values in AvRtpItuPerceivedSeverity
		SYNTAX	INTEGER
              {
              cleared (1),
              indeterminate (2),
              critical (3),
              major (4),
              minor (5),
              warning (6)
              }     
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The QoS problem severity for the stream. This item equals to 
          'warning' if a trap was suppose to be sent. and 'cleared' otherwise. "
        ::= { avRtpSessionEntry 19} 

 		avRtpSessionTxLen OBJECT-TYPE            
        SYNTAX  Integer32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The transmitted RTP packet size"
        ::= { avRtpSessionEntry 20}                
        
 		avRtpSessionType OBJECT-TYPE            
        SYNTAX INTEGER {
        	g711u(0),
        	g723(4),
        	g711a(8),
        	g722(9),
        	g728(15),
        	g729(18),
        	avayaFaxRelay(128),
        	t38fax(129),
        	faxPassThru(130),
        	ttyRelay(131),
        	ttyPassThru(132),
        	modemRelay(133),
        	modemPassThru(134),
        	clearChannel(135),        
        	g729a(136),
        	g729ab(137),  
        	g729b(138),
        	g726a32(139),
        	opus(140),
        	unspecified(255)
        }
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "This value describes the session type. It holds the RTP type for RTP streams and 
          unique items (above 127) for non-RTP or dynamically allocated types"
        ::= { avRtpSessionEntry 21} 
        
        avRtpSessionTxInterval OBJECT-TYPE            
        SYNTAX  Integer32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The interval (in milliseconds) between RTP packets."
        ::= { avRtpSessionEntry 22}     

 		avRtpSessionTxEncryp OBJECT-TYPE            
        SYNTAX INTEGER     { 
          unknown(-1), 
          encryptionOff(0),
          encryptionAEAv2(1),
          encryptionAES(2),
          srtpAesCm128(4),
          srtpAesCm128HmacSha180(5),
          srtpAesCm128HmacSha132(6),
          srtpF8128HmacSha180(7),
          srtpHmacSha180(8),
          srtpHmacSha132(9),
          srtp(10),
          srtpAesCm256(11),
          srtpAesCm256HmacSha180(12),
          srtpAesCm256HmacSha132(13)
		}
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The Media Encryption metric indicates what kind media encryption is 
          ,if any, is used for the RTP session. This information is valuable because:
          1)	media-encryption consumes more VoIP resources
          2)	Encryption key infrastructure may cause problems 

          encryptionOff(0) - Encryption is off
          encryptionAEAv2(1) - Avaya Proprietary AEAv2 encryption
          encryptionAES(2)  - Avaya Proprietary AES encryption

             Standard Encryption (Secure RTP):
          srtpAesCm128(4) - Counter Mode 128 AES encryption, no authentication
          srtpAesCm128HmacSha180(5) - AES encryption, 80bit SHA1 authentication
          srtpAesCm128HmacSha132(6) - AES encryption, 32bit SHA1 authentication
          srtpF8128HmacSha180(7) - F8 encryption, 80bit SHA1 authentication
          srtpHmacSha180(8) - No encryption, 80bit SHA1 authentication
          srtpHmacSha132(9) - No encryption, 32bit SHA1 authentication
		"
        ::= { avRtpSessionEntry 23}          

  		avRtpSessionTxDscp OBJECT-TYPE            
        SYNTAX INTEGER (0..63)
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The last transmitted IP DSCP. This value may change during the call according
          to the RSVP status.This information is valuable because routers may give 
          different priority to packets according to their DSCP value"
        ::= { avRtpSessionEntry 24} 

 		avRtpSessionTxVlan OBJECT-TYPE            
        SYNTAX INTEGER (-1..4095)
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The VLAN on which the RTP packets are transmitted. Minus one means 'unknown'"
        ::= { avRtpSessionEntry 25}                
        
 		avRtpSessionTxL2Pri OBJECT-TYPE            
        SYNTAX INTEGER (-1..7)
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The Layer 2 (e.g. IEEE 802.1p) priority of the sent Ethernet frames. Minus 1 
         means unknown. This information is valuable because Ethernet switches can give
          frames  different priority according to their 802.1p value"
        ::= { avRtpSessionEntry 26} 

 		avRtpSessionTxSilenceSupp OBJECT-TYPE            
        SYNTAX AvRtpSilenceSupp 
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "Silence suppression state.noRtp means that a simple silence suppression scheme 
         was used i.e. without RTP packets on silence. Complex means that a combination of 
         silence packets and 'no RTP on Silence' is usedThis information is valuable because:
          1)	silence suppression can save upto %60 bandwidth
          2)	Silence suppression influences user experience (especially if the terminals
            does not generate confort-noise)"
        ::= { avRtpSessionEntry 27}  

 		avRtpSessionTxSsrc OBJECT-TYPE            
        SYNTAX Unsigned32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The transmitted RTP stream SSRC.This value can be used to locate a stream in a packet capture."
        ::= { avRtpSessionEntry 28} 


  		avRtpSessionTxRsvp OBJECT-TYPE            
        SYNTAX INTEGER {unused(0), disabled(1), pending(2), failed(3), reserved(4)}
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The RSVP status for the stream. This information is valuable because:
         1)	Routers may reserve bandwidth to for the stream.
         2)	Avaya VoIP endpoints changes the transmitted DSCP according to 
         the RSVP status. "
        ::= { avRtpSessionEntry 29} 

 		avRtpSessionTxResvFail OBJECT-TYPE            
        SYNTAX Gauge32 
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The number of times the RSVP reservation has failed.
          This item is init to one if RSVP is in-use."
        ::= { avRtpSessionEntry 30}                
        
 		avRtpSessionStatInterval OBJECT-TYPE            
        SYNTAX TimeInterval
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The thresholds are evaluated periodically, usually 
         each time an RTCP message is being sent."
        ::= { avRtpSessionEntry 31} 
        
        avRtpSessionRxCodecPlayTime  OBJECT-TYPE            
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The time the codec has played frames (not including silence suppression or fill frames)"
        ::= { avRtpSessionEntry 32} 

        avRtpSessionRxCodecLossCount  OBJECT-TYPE            
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The total codec loss time in milliseconds "
        ::= { avRtpSessionEntry 33} 
        
        avRtpSessionRxCodecLoss  OBJECT-TYPE        
        SYNTAX AvRtpLoss
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The codec loss during the last Statistical interval, in 1/1000 units. 
          The codec loss is the number of fill period divided by the statistical interval.
          The fill period is  the duration of time that the codec had to send data to the digital
          to analog converter, but no codec frames  were available in the jitter buffer. 
          This is a measure for the overall packet loss after the jitter and resequencing re
          sequencing buffers."
         ::= { avRtpSessionEntry 34} 
         
        avRtpSessionRxAvgCodecLoss OBJECT-TYPE            
        SYNTAX AvRtpLoss
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The total codec loss during the session."
        ::= { avRtpSessionEntry 35} 
 
        avRtpSessionRxCodecLossEv  OBJECT-TYPE            
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The number of times codec loss was sampled over the threshold"
        ::= { avRtpSessionEntry 36}
        
        avRtpSessionRxLoss   OBJECT-TYPE            
        SYNTAX AvRtpLoss
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The received network loss in the last statistical interval (in 1/1000 units)."
        ::= { avRtpSessionEntry 37}
        
        avRtpSessionRxAvgLoss   OBJECT-TYPE            
        SYNTAX AvRtpLoss
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The total network loss during the session (in 1/1000 units)."
        ::= { avRtpSessionEntry 38}
        
        avRtpSessionRxLossEv   OBJECT-TYPE            
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The number of times network loss was sampled over the threshold"
        ::= { avRtpSessionEntry 39}
      
        
 		avRtpSessionRx OBJECT-TYPE            
        SYNTAX  Counter32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The total number of received RTP packets"
        ::= { avRtpSessionEntry 40}  
        
  		avRtpSessionRxLossCount OBJECT-TYPE            
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The total number of lost packets"
        ::= { avRtpSessionEntry 41} 

 		avRtpSessionRxSeqFall OBJECT-TYPE            
        SYNTAX Counter32 
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The total number of sequence fall events"
        ::= { avRtpSessionEntry 42}                    
        
   		avRtpSessionRxDup OBJECT-TYPE            
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The total number of received duplicate packets.
          This item may indicate transient routing loop"
        ::= { avRtpSessionEntry 43} 

        
		avRtpSessionRxJBufUnderruns OBJECT-TYPE            
        SYNTAX Gauge32 
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The duration of jitter buffer under runs during the call in milliseconds (i.e.
          buffer empty when a frame is needed by the codec)."
        ::= { avRtpSessionEntry 44} 

 		avRtpSessionRxJBufOverruns OBJECT-TYPE            
        SYNTAX  Gauge32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The duration of time in codec frames that were dropped due to jitter buffer overruns 
         in milliseconds (i.e. jitter buffer is full)"
        ::= { avRtpSessionEntry 45} 

		avRtpSessionRxJBufDelay OBJECT-TYPE            
        SYNTAX Integer32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The last jitter buffer delay in milliseconds."
        ::= { avRtpSessionEntry 46}    
        
		avRtpSessionRxMaxJBufDelay OBJECT-TYPE            
        SYNTAX  Integer32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The maximum jitter buffer delay during the call (in milliseconds)"
        ::= { avRtpSessionEntry 47}    
                                                            
                                                            
	    avRtpSessionRxJitter  OBJECT-TYPE            
        SYNTAX  Integer32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The last/current  received RTP jitter"
        ::= { avRtpSessionEntry 48}    


		avRtpSessionRxAvgJitter   OBJECT-TYPE            
        SYNTAX  Integer32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The average received RTP jitter"
        ::= { avRtpSessionEntry 49}    
				
				                                                            
		avRtpSessionRxJitterEv OBJECT-TYPE            
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The number of times, jitter was sampled over the threshold."
        ::= { avRtpSessionEntry 50}   

 		avRtpSessionRxTtl OBJECT-TYPE            
        SYNTAX INTEGER (0..255)
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The current/last received TTL value (IP Time To Live)"
        ::= { avRtpSessionEntry 51} 

		avRtpSessionRxMinTtl OBJECT-TYPE            
        SYNTAX  INTEGER (0..255)
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The minimum received TTL value. The technician can use this value as a 
         hint to what was the IP route during the session. "
        ::= { avRtpSessionEntry 52}    
        
		avRtpSessionRxMaxTtl OBJECT-TYPE            
        SYNTAX   INTEGER (0..255)
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The maximum received TTL value. Difference between this value and 
         avRtpSessionRxMinTtl may indicate route changes during the call."
        ::= { avRtpSessionEntry 53}    

        
		avRtpSessionRxDscp OBJECT-TYPE            
        SYNTAX INTEGER (0..63)
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The last received DSCP value."
        ::= { avRtpSessionEntry 54}                                                                                                               

		avRtpSessionRxL2Pri OBJECT-TYPE            
        SYNTAX  INTEGER (-1..7)
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The last received L2 priority  (IEEE 802.1p, Ethernet priority)"
        ::= { avRtpSessionEntry 55}    

		avRtpSessionRxSilenceSupp OBJECT-TYPE            
        SYNTAX  AvRtpSilenceSupp
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The observed (received) silence suppression technique."
        ::= { avRtpSessionEntry 56}    

		avRtpSessionRxSsrc OBJECT-TYPE            
        SYNTAX Unsigned32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The last received RTP SSRC value"
        ::= { avRtpSessionEntry 57}    

		avRtpSessionRxSsrcChange OBJECT-TYPE            
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "Counts the number of observed SSRC changes during the call. This may indicate 
           a remote VoIP engine fail-over event."
        ::= { avRtpSessionEntry 58}    
        
		avRtpSessionTxRtcp OBJECT-TYPE            
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The total number of transmitted RTCP reports"
        ::= { avRtpSessionEntry 59}    


		avRtpSessionRxRtcp OBJECT-TYPE            
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The total number of received RTCP reports"
        ::= { avRtpSessionEntry 60}    

		avRtpSessionCodecRtt OBJECT-TYPE            
        SYNTAX Integer32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The Estimated analog overall round-trip time calculated from the last received
          RTCP packet. The estimate value include the network delay plus the internal delays
           plus an estimate for the remote internal delay. This value is measured in
            milliseconds."
        ::= { avRtpSessionEntry 61}    

		avRtpSessionAvgCodecRtt OBJECT-TYPE            
        SYNTAX   Integer32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The Avarage Estimated analog overall  RTT (including internal delays) 
          during the session."
        ::= { avRtpSessionEntry 62}    

		avRtpSessionCodecRttEv OBJECT-TYPE            
        SYNTAX  Counter32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The number of times the Estimated analog codec  RTT was over the threshold"
         ::= { avRtpSessionEntry 63}    


		avRtpSessionRtt OBJECT-TYPE            
        SYNTAX Integer32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The last RTT value in milliseconds. RTT is learnt from RTCP reports"
        ::= { avRtpSessionEntry 64}    

		avRtpSessionAvgRtt OBJECT-TYPE            
        SYNTAX   Integer32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The average RTT during the RTP sessions"
        ::= { avRtpSessionEntry 65}    

		avRtpSessionRttEv OBJECT-TYPE            
        SYNTAX  Counter32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The number of received RTCP packets which has indicated that RTT was 
         over the threshold."
        ::= { avRtpSessionEntry 66}    
                                  
                                  
                                  
		avRtpSessionRemLoss OBJECT-TYPE            
        SYNTAX AvRtpLoss
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The last known remote loss (learnt from received RTCP message)"
        ::= { avRtpSessionEntry 67}    

		avRtpSessionRemAvgLoss OBJECT-TYPE            
        SYNTAX AvRtpLoss
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The last known remote loss (learnt from received RTCP message)"
        ::= { avRtpSessionEntry 68}    

		avRtpSessionRemLossEv OBJECT-TYPE            
        SYNTAX  Counter32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The number of received RTCP packets which has indicated that loss, at the remote
          peer,  was over the threshold.."
        ::= { avRtpSessionEntry 69}    
        
        
		avRtpSessionRemJitter OBJECT-TYPE            
        SYNTAX  Integer32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The last known remote jitter, learnt from RTCP."
        ::= { avRtpSessionEntry 70}    

		avRtpSessionRemAvgJitter OBJECT-TYPE            
        SYNTAX  Integer32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The average remote jitter, learnt from RTCP."
        ::= { avRtpSessionEntry 71}    


		avRtpSessionRemJitterEv OBJECT-TYPE            
        SYNTAX Counter32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The number of received RTCP messages, which have indicated that loss was over 
         the threshold."
        ::= { avRtpSessionEntry 72}    

		avRtpSessionEcTailLen OBJECT-TYPE            
        SYNTAX Integer32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The current/last echo cancellation tail length."
        ::= { avRtpSessionEntry 73}    

		avRtpSessionEcReturnLoss OBJECT-TYPE            
        SYNTAX  INTEGER (0..100)
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The last sampled Echo Cancellation return loss. "
        ::= { avRtpSessionEntry 74}        
                                           
		avRtpSessionEcReturnLossEv OBJECT-TYPE            
        SYNTAX  Counter32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The number of time the echo cancellation return loss was sampled over the 
         threshold. This value is sampled every avRtpSessionStatInerval"
        ::= { avRtpSessionEntry 75}                                                   

        avRtpSessionAEC OBJECT-TYPE            
        SYNTAX  INTEGER {
                 notSupported(0),
                 none(1),
                 halfDuplex(2),
                 fullDuplex(3),
                 aec(4)}
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "Acoustic echo cancellation state, relevant for speaker phones"
        ::= { avRtpSessionEntry 76} 
        
        avRtpSessionDebugStr OBJECT-TYPE            
        SYNTAX  DisplayString (SIZE (0..255))
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "This string contains the major metrics in human readable form. It is used by
          the QoS trap."
        ::= { avRtpSessionEntry 77}     
        
  		avRtpSessionTxFlowLabel OBJECT-TYPE            
        SYNTAX INTEGER (0..1048575)
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
		 "The last transmitted IPv6 Flow Label. This metric represents the most recently 
		 transmitted IPv6 Flow Label field in the IPv6 RTP stream. The value fits in a
		 20-bit integer and is reset to zero et the start of each new RTP session."
        ::= { avRtpSessionEntry 78} 

  		avRtpSessionRxFlowLabel OBJECT-TYPE            
        SYNTAX INTEGER (0..1048575)
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
		 "The last Received IPv6 Flow Label. This metric represents the value of the IPv6 
		 Flow Label field of the incoming RTP packets. The Received IPv6 Flow Label metric 
		 is a 20-bit integer. The metric is set with the first IPv6 RTP packet received,
		 and updated when the value has changed from the previously reported value."
        ::= { avRtpSessionEntry 79} 
        
        
avRtpSumTable OBJECT-TYPE
    SYNTAX SEQUENCE OF AvRtpSumEntry
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION
      "This table contains summary of sessions and QoS events for each VoIP engine."
    ::= { avRtpMib 3 }

      avRtpSumEntry OBJECT-TYPE
            SYNTAX AvRtpSumEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION 
              " "
            INDEX { avRtpSumEngineID}
            ::= { avRtpSumTable 1 }
        
        AvRtpSumEntry ::=
            SEQUENCE {  
            	avRtpSumEngineID	Integer32,
				avRtpSumEngineDescr	DisplayString,
				avRtpSumPeriod	TimeInterval,
				avRtpSumActiveFlows	Integer32,
				avRtpSumActiveQosEvents	Integer32,
				avRtpSumTotalFlows	Counter32,
				avRtpSumTotalFlowsQoSEvents	Counter32,
				avRtpSumTxTTL	INTEGER,  
				avRtpSumSessionDuration Counter32,
				avRtpSumClear	TruthValue          
				}
                           
                           

		avRtpSumEngineID OBJECT-TYPE            
        SYNTAX  Integer32
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "VoIP engine identifier. Usually, the VoIP engine slot number."
        ::= { avRtpSumEntry 1 }                               

		avRtpSumEngineDescr OBJECT-TYPE            
        SYNTAX DisplayString (SIZE (0..32))
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "A string describing the VoIP engine. 
         Equals to entPhysicalDescr or cmgModuleDescription "
        ::= { avRtpSumEntry 2}                               

		avRtpSumPeriod OBJECT-TYPE            
        SYNTAX TimeInterval 
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The time since the summary counters were cleared."
        ::= { avRtpSumEntry 3}                               

		avRtpSumActiveFlows OBJECT-TYPE            
        SYNTAX Integer32 
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The number of active flows"
        ::= { avRtpSumEntry 4}                               

		avRtpSumActiveQosEvents OBJECT-TYPE            
        SYNTAX Integer32 
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The number of flows that currently suffers from QoS problems."
        ::= { avRtpSumEntry 5}                               

		avRtpSumTotalFlows OBJECT-TYPE            
        SYNTAX Counter32 
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The total number of flows"
        ::= { avRtpSumEntry 6}                               

		avRtpSumTotalFlowsQoSEvents OBJECT-TYPE            
        SYNTAX Counter32 
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The total number of flows that had QoS events"
        ::= { avRtpSumEntry 7}                               

		avRtpSumTxTTL OBJECT-TYPE            
        SYNTAX INTEGER (0..255) 
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "TTL of transmitted RTP packets."
        ::= { avRtpSumEntry 8}                               
      
        avRtpSumSessionDuration  OBJECT-TYPE            
        SYNTAX Counter32 
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "Total duration of the sessions in seconds"
        ::= { avRtpSumEntry 9}                               
        
      	avRtpSumClear OBJECT-TYPE            
        SYNTAX TruthValue 
        MAX-ACCESS read-write
        STATUS current            
        DESCRIPTION
         "Clear the summary counters"
        ::= { avRtpSumEntry 10}       
        
        

avRtpLookupTable OBJECT-TYPE
   SYNTAX SEQUENCE OF AvRtpLookupEntry
   MAX-ACCESS not-accessible
   STATUS current
   DESCRIPTION
      "This virtual table is used for finding a specific SessionIDs based
        on the remote address and call state."
   ::= { avRtpMib 4 }

      avRtpLookupEntry OBJECT-TYPE
            SYNTAX AvRtpLookupEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION ""
             INDEX { avRtpSessionRemAddrType, avRtpSessionRemAddr, avRtpSessionState, avRtpSessionID }
            ::= { avRtpLookupTable 1 }
 
         AvRtpLookupEntry ::=
            SEQUENCE { avRtpLookupStartTime	DateAndTime } 
            	
       
  		avRtpLookupStartTime OBJECT-TYPE            
        SYNTAX DateAndTime
        MAX-ACCESS read-only
        STATUS current            
        DESCRIPTION
         "The stream start time"
        ::= { avRtpLookupEntry 1}                       
        
       
avRtpNotificationVarbinds OBJECT-IDENTITY
       	STATUS current
        DESCRIPTION
        "Notify only varbinds used for
        notifications in avRtpNotification group"
        ::= { avRtpMib 5 }

avRtpSessionLocInetAddrType OBJECT-TYPE
        SYNTAX InetAddressType
        MAX-ACCESS accessible-for-notify
        STATUS current
        DESCRIPTION
        "The RTP stream local RTP address Type (IPv4/IPv6)."
        ::= { avRtpNotificationVarbinds 1 }
                
avRtpSessionLocInetAddr OBJECT-TYPE
      	SYNTAX InetAddress
     	MAX-ACCESS accessible-for-notify
     	STATUS current
     	DESCRIPTION
     	"The RTP stream local RTP address (IPv4/IPv6)."
     	::= { avRtpNotificationVarbinds 2 }

avRtpSessionRemInetAddrType OBJECT-TYPE
        SYNTAX InetAddressType
        MAX-ACCESS accessible-for-notify
        STATUS current
        DESCRIPTION
        "The RTP stream remote RTP address Type (IPv4/IPv6)."
        ::= { avRtpNotificationVarbinds 3 }
                
avRtpSessionRemInetAddr OBJECT-TYPE
      	SYNTAX InetAddress
     	MAX-ACCESS accessible-for-notify
     	STATUS current
     	DESCRIPTION
     	"The RTP stream remote RTP address (IPv4/IPv6)."
     	::= { avRtpNotificationVarbinds 4 }     
END