CADANT-SW-MEAS-MIB DEFINITIONS ::= BEGIN

IMPORTS
    OBJECT-TYPE, 
    MODULE-IDENTITY, 
    Integer32, 
    Unsigned32,
    Counter32, 
    Counter64
	FROM SNMPv2-SMI
    DisplayString, 
    MacAddress,
    TEXTUAL-CONVENTION
	FROM SNMPv2-TC
    InterfaceIndex, 
    ifIndex
	FROM IF-MIB
    CardId
	FROM CADANT-TC
    cadExperimental
        FROM CADANT-PRODUCTS-MIB;
        
cadSoftwareMeasMib MODULE-IDENTITY
    LAST-UPDATED "201409040000Z"  -- Sep 4, 2014
    ORGANIZATION 
	"Arris International, Inc."
    CONTACT-INFO 
	"Arris Technical Support
	 Postal: ARRIS
	 E-Mail: support@arrisi.com"
	DESCRIPTION	"This Mib Module contains all of the soft counts associated with software in the Arris C4 CMTS."


    REVISION "201409040000Z"  -- Sep 4, 2014
    DESCRIPTION "Add global scaling counts and cadCamScaleTable."

    REVISION "201207070000Z"  -- July 7, 2012
    DESCRIPTION "Remove cadUpChannelULBOverride."

    REVISION "200612140000Z"
    DESCRIPTION "Modify the index of cadSWUChannelMeasEntry."


    REVISION "200604140000Z"
    DESCRIPTION "Removed cadUpChannelAvgContSlots. (moved to CADANT-HW-MEAS-MIB)"

    REVISION "200602080000Z"
    DESCRIPTION "Added additional UGS measurements."

    REVISION "200601300000Z"
    DESCRIPTION "Added implementation per utilization interval for cadUpChannelAvgContSlots, cadUpChannelAvgUtil."

    REVISION "200601240000Z"
    DESCRIPTION "Add delta count implementation ."

    REVISION "200601100000Z"
    DESCRIPTION "Added UGS count / measurements for Time Warner."

    REVISION "200510110000Z"
    DESCRIPTION "Added support for intelligent channel optimization."

    REVISION "200508180000Z"
    DESCRIPTION "Added cadUpChannelIngressCancellationBandwidth."

    REVISION "200312220000Z" 
    DESCRIPTION "added cadUpChannelRequestSizeMslots and cadUpChannelInitialMaintSizeMslots"

    REVISION "200110230000Z"
    DESCRIPTION "created"

        ::= { cadExperimental 9 }


--==================SW Scale Group ==================--
--
cadChassisScaleGroup         OBJECT IDENTIFIER  ::= { cadSoftwareMeasMib 1 }

cadantTotalDevices OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION 
            "The current total number of devices in the E6000 CER."
        ::= { cadChassisScaleGroup 1 }

cadantDsBondedDevices OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION 
                "The current total number of DS bonded devices in the E6000 CER."
        ::= { cadChassisScaleGroup 2 }

cadantUsBondedDevices OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION 
            "The current total number of US bonded devices in the E6000 CER."
        ::= { cadChassisScaleGroup 3 }

cadantTotalServiceFlows OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION 
            "The current total number of SFs in the E6000 CER."
        ::= { cadChassisScaleGroup 4 }

cadantTotalClassifiers OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
       DESCRIPTION 
            "The current total number of classifiers in the E6000 CER."
        ::= { cadChassisScaleGroup 5 }

cadantTotalArpEntries OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION 
            "The current total number of ARP table entries for IPv4
             addresses in the E6000 CER."
        ::= { cadChassisScaleGroup 6 }

cadantTotalIpv4Routes OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION 
            "The current total number of IPv4 routes in the E6000 CER."
        ::= { cadChassisScaleGroup 7 }

cadantTotalNdEntries OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION 
            "The current total number of Neighbor Discovery entries for
             IPv6 addresses in the E6000 CER."
        ::= { cadChassisScaleGroup 8 }

cadantTotalIpv6Routes OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION 
            "The current total number of IPv6 routes in the E6000 CER."
        ::= { cadChassisScaleGroup 9 }

cadantDocsisMulticastStreams OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION 
            "The current total number of DOCSIS multicast streams that
             are currently joined."
        ::= { cadChassisScaleGroup 10 }

cadantVideoMulticastStreams OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION 
            "The current total number of IEQ video multicast streams that
             are currently joined."
        ::= { cadChassisScaleGroup 11 }

cadantTotalCpe OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION 
            "The current total number of cpe devices in the E6000 CER."
        ::= { cadChassisScaleGroup 12 }



--======= U Port SW Meas Table ===============
--
cadSWUChannelMeasTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF CadSWUChannelMeasEntry
    MAX-ACCESS      not-accessible
    STATUS  current
    DESCRIPTION
	" This table contains software counts in the upstream channels."
    ::= { cadSoftwareMeasMib 2 }

cadSWUChannelMeasEntry OBJECT-TYPE
    SYNTAX  CadSWUChannelMeasEntry
    MAX-ACCESS      not-accessible
    STATUS  current
    DESCRIPTION
    "List of counts or measurements for a single upstream channel. 
	 For Docsis 2.0 CMTSs, an entry in this table exists for 
     each ifEntry with an ifType of docsCableUpstreamChannel (205).
     For Docsis 1.x CM/CMTSs and Docsis 2.0 CMs, an entry in this table exists 
     for each ifEntry with an ifType of docsCableUpstreamInterface (129)."
    INDEX { ifIndex }
        ::= { cadSWUChannelMeasTable  1 }

CadSWUChannelMeasEntry ::= SEQUENCE {
    cadUpChannelRequestSizeMslots      Counter64,
    cadUpChannelInitialMaintSizeMslots Counter64,
    cadUpChannelIngressCancellationBandwidth Integer32,
    cadUpChannelAttenuation            Integer32,
    cadUpChannelRFCalibration          OCTET STRING,
    cadUpChannelTScale                 Integer32,
    cadUpChannelSScale                 Integer32
}

cadUpChannelRequestSizeMslots OBJECT-TYPE
    SYNTAX                  Counter64
    MAX-ACCESS              read-only
    STATUS                  current
    DESCRIPTION "" 
    ::= { cadSWUChannelMeasEntry  2 }

cadUpChannelInitialMaintSizeMslots OBJECT-TYPE
    SYNTAX                  Counter64
    MAX-ACCESS              read-only
    STATUS                  current
    DESCRIPTION "" 
    ::= { cadSWUChannelMeasEntry  3 }

cadUpChannelIngressCancellationBandwidth OBJECT-TYPE
    SYNTAX       Integer32 (0..100)
    UNITS        "percent"
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION 
	"The utilization index is a percentage expressing the ratio between 
	 minislots reserved for ingress cancellation analysis versus the total 
	 number of minislots for upstream transmission.
	 Formula:
	   ingress cancellation bandwidth = 
	    (cancellation_minislots_per_second / total_minislots_per_second) * 100% "
    ::= { cadSWUChannelMeasEntry 4 }

cadUpChannelAttenuation OBJECT-TYPE
    SYNTAX                  Integer32
    MAX-ACCESS              read-only
    STATUS                  current
    DESCRIPTION 
        "RF input amplifier attenuation" 
    ::= { cadSWUChannelMeasEntry  5 }

cadUpChannelRFCalibration OBJECT-TYPE
    SYNTAX                  OCTET STRING (SIZE(3))
    MAX-ACCESS              read-only
    STATUS                  current
    DESCRIPTION 
        "Factory RF calibration settings."
    ::= { cadSWUChannelMeasEntry  6 }

cadUpChannelTScale OBJECT-TYPE
    SYNTAX                  Integer32
    MAX-ACCESS              read-only
    STATUS                  current
    DESCRIPTION 
        "TDMA nominal burst gain adjusting factor" 
    ::= { cadSWUChannelMeasEntry  7 }

cadUpChannelSScale OBJECT-TYPE
    SYNTAX                  Integer32
    MAX-ACCESS              read-only
    STATUS                  current
    DESCRIPTION 
        "SCDMA nominal burst gain adjusting factor" 
    ::= { cadSWUChannelMeasEntry  8 }


--
-- counts / measurements for logical upstream channel
--
cadUpChannelStatsTable OBJECT-TYPE
    SYNTAX SEQUENCE OF CadUpChannelStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of counts and measurements for a logical upstream
		 channel."
    ::= { cadSoftwareMeasMib 3 }

cadUpChannelStatsEntry OBJECT-TYPE
    SYNTAX      CadUpChannelStatsEntry 
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The measurements for a logical upstream channel."
    INDEX { ifIndex } -- ifType of 205    
	::= { cadUpChannelStatsTable 1 } 

CadUpChannelStatsEntry ::= SEQUENCE {
    cadUpChannelMaxUGSLastOneHour   Unsigned32,
    cadUpChannelAvgUGSLastOneHour   Unsigned32,
    cadUpChannelMinUGSLastOneHour   Unsigned32,
    cadUpChannelMaxUGSLastFiveMins  Unsigned32,
    cadUpChannelAvgUGSLastFiveMins  Unsigned32,
    cadUpChannelMinUGSLastFiveMins  Unsigned32,
    cadUpChannelNormalUGSDeniedLastOneHour       Unsigned32,
    cadUpChannelNormalUGSDeniedLastFiveMins      Unsigned32,
    cadUpChannelEmergencyUGSDeniedLastOneHour    Unsigned32,
    cadUpChannelEmergencyUGSDeniedLastFiveMins   Unsigned32,
    cadUpChannelTotalNormalUGSLastOneHour        Unsigned32,
    cadUpChannelTotalNormalUGSLastFiveMins       Unsigned32,
    cadUpChannelTotalEmergencyUGSLastOneHour     Unsigned32,
    cadUpChannelTotalEmergencyUGSLastFiveMins    Unsigned32
}

cadUpChannelMaxUGSLastOneHour OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
            "This object indicates the maximum number of 
             Unsolicited Grant Service (UGS) allocated on a
             given upstream in the last one hour. This would be
             used for the user to evaluate traffic load at any
             given time of the day."
    ::= { cadUpChannelStatsEntry 1 }

cadUpChannelAvgUGSLastOneHour OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
            "This object indicates the average number of 
             Unsolicited Grant Service (UGS) allocated on a
             given upstream in the last one hour. This would be
             used for the user to evaluate traffic load at any
             given time of the day."
    ::= { cadUpChannelStatsEntry 2 }

cadUpChannelMinUGSLastOneHour OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
            "This object indicates the minimum number of 
             Unsolicited Grant Service (UGS) allocated on a
             given upstream in the last one hour. This would be
             used for the user to evaluate traffic load at any
             given time of the day."
    ::= { cadUpChannelStatsEntry 3 }

cadUpChannelMaxUGSLastFiveMins OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
            "This object indicates the maximum number of 
             Unsolicited Grant Service (UGS) allocated on a
             given upstream in the last five minutes. This would 
             be used for the user to evaluate traffic load at
             any given time of the day."
    ::= { cadUpChannelStatsEntry 4 }

cadUpChannelAvgUGSLastFiveMins OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
            "This object indicates the average number of 
             Unsolicited Grant Service (UGS) allocated on a
             given upstream in the last five minutes. This would 
             be used for the user to evaluate traffic load at
             any given time of the day."
    ::= { cadUpChannelStatsEntry 5 }

cadUpChannelMinUGSLastFiveMins OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
            "This object indicates the minimum number of 
             Unsolicited Grant Service (UGS) allocated on a
             given upstream in the last five minutes. This would 
             be used for the user to evaluate traffic load at
             any given time of the day."
    ::= { cadUpChannelStatsEntry 6 }

cadUpChannelNormalUGSDeniedLastOneHour OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
       "This object indicates the total normal calls that were denied in the last one hour."
    ::= { cadUpChannelStatsEntry 7 }

cadUpChannelNormalUGSDeniedLastFiveMins OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
       "This object indicates the total normal calls that were denied in the last 5 minutes."
    ::= { cadUpChannelStatsEntry 8 }

cadUpChannelEmergencyUGSDeniedLastOneHour OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
       "This object indicates the total emergency calls that were denied in the last one hour."
    ::= { cadUpChannelStatsEntry 9 }

cadUpChannelEmergencyUGSDeniedLastFiveMins OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
       "This object indicates the total emergency calls that were denied in the last 5 minutes."
    ::= { cadUpChannelStatsEntry 10 }

cadUpChannelTotalNormalUGSLastOneHour OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
       "This object indicates the total normal calls in the last one hour."
    ::= { cadUpChannelStatsEntry 11 }

cadUpChannelTotalNormalUGSLastFiveMins OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
       "This object indicates the total normal calls in the last 5 minutes."
    ::= { cadUpChannelStatsEntry 12 }

cadUpChannelTotalEmergencyUGSLastOneHour OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
       "This object indicates the total emergency calls in the last one hour."
    ::= { cadUpChannelStatsEntry 13 }

cadUpChannelTotalEmergencyUGSLastFiveMins OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION 
       "This object indicates the total emergency calls in the last 5 minutes."
    ::= { cadUpChannelStatsEntry 14 }


--======= CAM Scale Table ===============
--

cadCamScaleTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF CadCamScaleEntry
    MAX-ACCESS      not-accessible
    STATUS  current
    DESCRIPTION
       "This table contains scale counts per non-spare CAM."
    ::= { cadSoftwareMeasMib 4 }

cadCamScaleEntry OBJECT-TYPE
    SYNTAX  CadCamScaleEntry
    MAX-ACCESS      not-accessible
    STATUS  current
    DESCRIPTION
    "The current scale counts for this non-spare CAM."
    INDEX { cadCamScaleCardId }
        ::= { cadCamScaleTable  1 }

CadCamScaleEntry ::= SEQUENCE {
    cadCamScaleCardId          CardId,
    cadCamScaleDevices         Unsigned32,
    cadCamScaleBondedDevices   Unsigned32,
    cadCamScaleServiceFlows    Unsigned32,
    cadCamScaleClassifiers     Unsigned32,
    cadCamScaleIpv4Addresses   Unsigned32,
    cadCamScaleIpv6Addresses   Unsigned32,
    cadCamScaleUsRangeCount    Unsigned32,
    cadCamScaleTotalCpe        Unsigned32
}

cadCamScaleCardId OBJECT-TYPE
    SYNTAX   CardId (1..6 | 9..14)
    MAX-ACCESS              not-accessible
    STATUS                  current
    DESCRIPTION "Card Id of the Cam. There is no row for spare CAM slots." 
    ::= { cadCamScaleEntry  1 }

cadCamScaleDevices OBJECT-TYPE
    SYNTAX                  Unsigned32
    MAX-ACCESS              read-only
    STATUS                  current
    DESCRIPTION 
        "Current number of devices on the CAM." 
    ::= { cadCamScaleEntry  2 }

cadCamScaleBondedDevices OBJECT-TYPE
    SYNTAX                  Unsigned32
    MAX-ACCESS              read-only
    STATUS                  current
    DESCRIPTION 
        "Current number of bonded devices on the CAM." 
    ::= { cadCamScaleEntry  3 }

cadCamScaleServiceFlows OBJECT-TYPE
    SYNTAX                  Unsigned32
    MAX-ACCESS              read-only
    STATUS                  current
    DESCRIPTION 
        "Current number of DS SFs on a DCAM. 
         Current number US SFs on a UCAM." 
    ::= { cadCamScaleEntry  4 } 

cadCamScaleClassifiers OBJECT-TYPE
    SYNTAX                  Unsigned32
    MAX-ACCESS              read-only
    STATUS                  current
    DESCRIPTION 
        "Current number of Classifiers in use on the CAM." 
    ::= { cadCamScaleEntry  5 } 

cadCamScaleIpv4Addresses OBJECT-TYPE
    SYNTAX                  Unsigned32
    MAX-ACCESS              read-only
    STATUS                  current
    DESCRIPTION 
        "Current number of IPv4 addresses on the CAM." 
    ::= { cadCamScaleEntry  6 } 

cadCamScaleIpv6Addresses OBJECT-TYPE
    SYNTAX                  Unsigned32
    MAX-ACCESS              read-only
    STATUS                  current
    DESCRIPTION 
        "Current number of IPv6 Addresses on the CAM." 
    ::= { cadCamScaleEntry  7 }

cadCamScaleUsRangeCount OBJECT-TYPE
    SYNTAX                  Unsigned32
    MAX-ACCESS              read-only
    STATUS                  current
    DESCRIPTION 
        "Total US channels requiring ranging. Each CM with N channels 
         in-service to this UCAM adds N to the count (e.g., a 4 US bonded
         CM adds 4 to this count). Unbonded modems add one to the count.
         For DCAMs, this count is always zero." 
    ::= { cadCamScaleEntry  8 }

cadCamScaleTotalCpe OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION 
            "The current total number of cpe devices on this CAM."
        ::= { cadCamScaleEntry  9 }

END