CADANT-HW-MEAS-MIB DEFINITIONS ::= BEGIN

IMPORTS
        OBJECT-TYPE, MODULE-IDENTITY, Integer32, Counter32, Counter64, Unsigned32, Gauge32
                FROM SNMPv2-SMI
        DisplayString, MacAddress, TEXTUAL-CONVENTION, TimeStamp, TruthValue
                FROM SNMPv2-TC
        InterfaceIndex, ifIndex
                FROM IF-MIB
        IfDirection
                FROM DOCS-QOS3-MIB
        docsSubmgt3FilterGrpEntry
                FROM DOCS-SUBMGT3-MIB
        TenthdB
                FROM DOCS-IF-MIB
        cadEquipment
                FROM CADANT-PRODUCTS-MIB
        cadIfMacDomainIfIndex
                FROM CADANT-CMTS-LAYER2CMTS-MIB
        cadIfCmtsCmStatusMacAddress
                FROM CADANT-CMTS-MAC-MIB
        cadIf3CmtsCmUsStatusChIfIndex
                FROM CADANT-CMTS-IF3-MIB
        pktcEScTapMediationContentId, pktcEScTapStreamIndex
                FROM PKTC-ES-TAP-MIB
        CadIfDirection, CardId, PortId
                FROM CADANT-TC;
        
cadHardwareMeasMib MODULE-IDENTITY
      LAST-UPDATED "201508270000Z" -- August 27, 2015
      ORGANIZATION 
          "Arris International, Inc."
      CONTACT-INFO 
          "Arris Technical Support
           E-Mail: support@arrisi.com"
      DESCRIPTION 
          "This Mib Module contains all of the counts that are associated
           with hardware in the ARRIS C4 CMTS. Many of these MIB variables
           contain the same counts as found in the standard MIBs. However, the
           grouping of these variables is done for the convenience of the Cadant
           engineering team. These tables can be used to build value-added interfaces
           to the Cadant ARRIS C4 CMTS. "



    REVISION "201508270000Z" -- August 27, 2015
    DESCRIPTION
        "Add cadantDPortMeasOfdmChanUtilization"

    REVISION "201507130000Z" -- July 13, 2015
    DESCRIPTION
        "Add cadInterfaceHighResUtilizationPercentage and cadInterfaceIntervalOctetsForwarded"

    REVISION "201506030000Z" -- Jun 3, 2015
    DESCRIPTION
        "Add cadantDPortMeasDfdmIfSpeed, cadantDPortMeasOfdmHighestAvgBitsPerSubc, and
         cadantDPortMeasOfdmNumDataSubc"

    REVISION "201410140000Z" -- Oct 14, 2014
    DESCRIPTION
        "Support 384 downstream channels per DCAM-B"

      REVISION "201406130000Z" -- Jun 13, 2014
      DESCRIPTION "Add back in cadFftUpstreamChannelTable"

      REVISION "201406040000Z" -- Jun 4, 2014
      DESCRIPTION "Add cadDCardIgmpThrottleDropPkts."

      REVISION "201311220000Z" -- Nov 22, 2013
      DESCRIPTION "Remove cadFftUpstreamChannelTable"

      REVISION "201210300000Z" -- Oct 30, 2012
      DESCRIPTION "Add cadLaesCountTable"
      
      REVISION "201205090000Z" -- May 9, 2012
      DESCRIPTION "Remove cadHWCmUsMeasTable"

      REVISION "201108310000Z" -- Aug 31, 2011
      DESCRIPTION "Remove cadantUPortMeasMapFrms"

      REVISION "201106290000Z" -- Jun 29, 2011
      DESCRIPTION "Remove cadSFIDMeasEntry"

      REVISION "201102280000Z" -- Feb 28, 2011
      DESCRIPTION "Deprecate cadSFIDMeasEntry and add the following MIB objects to cadantUFIDMeasEntry
                   cadantUFIDMeasCcfStatsSgmtValids, cadantUFIDMeasCcfStatsSgmtLost and
                   cadantUFIDMeasCcfStatsSgmtDrop."

      REVISION "201102240000Z" -- Feb 24, 2011
      DESCRIPTION "Remove cadSFIDToSIDEntry"

      REVISION "201102180000Z" -- Feb 18, 2011
      DESCRIPTION "Add cadantUFIDMeasSIDMacIfIndex and cadantUFIDMeasSIDBonded 
                   to cadantUFIDMeasEntry"

      REVISION "201011220000Z" -- Nov 22, 2010
      DESCRIPTION "Change indices of cadDFIDMeasEntry as ifIndex and SFID. 
                   Change indices of cadantUFIDMeasEntry as ifIndex and SID"

      REVISION "201003090000Z" -- March 9, 2010
      DESCRIPTION "Add cadDCardDhcpV6ThrottleDropPkts and cadDCardNdThrottleDropPkts."

      REVISION "200811240000Z" -- Nov 24, 2008
      DESCRIPTION "Add cadHWCmUsMeasEntry"

      REVISION "200811210000Z" -- Nov 21, 2008
      DESCRIPTION "Restructure cadantHWUFIDMeasEntry, rename cadantUFIDMeasUFID to cadantUFIDMeasSID, and
                   Add cadantHWMeasUFIDIndex"
      
      REVISION "200811050000Z" -- Nov 5, 2008
      DESCRIPTION "Restructure cadSFIDMeasEntry to support docsQosServiceFlowCcfStatsEntry"

      REVISION "200804240000Z" -- April 24, 2008
      DESCRIPTION "Use ifindex as key for sfid to sid lookup."

      REVISION "200609140000Z" -- September 14, 2006
      DESCRIPTION "Remove fabric tables and add CPWRED tables to match implementation."

      REVISION "200604140000Z"
      DESCRIPTION "Added implementation per utilization interval for cadInterfaceUtilizationAvgContSlots."

      REVISION "200507130000Z"
      DESCRIPTION "Added cadDFIDMeasPolicedDelayPkts for Traffic Shaping feature."

      REVISION "200412100000Z"
      DESCRIPTION "Extended cadSubMgtPktFilterExtTable to allow for packet capturing."

      REVISION "200408310000Z"
      DESCRIPTION "Added cadSubMgtPktFilterExtTable to reset docsSubMgtPktFilterMatches."

      REVISION "200404090000Z"
      DESCRIPTION "Added cadFftUpstreamChannelTable for FFT counts."

      REVISION "200403090000Z"
      DESCRIPTION "Added cadInterfaceUtilizationTable"

      REVISION "200402230000Z"
      DESCRIPTION "Added support for per-SID HCS and CRC errors."

      REVISION "200402180000Z"
      DESCRIPTION "Added cadantDPortMeasIfOutTotalOctets"

      REVISION "200402150000Z"
      DESCRIPTION "Added support for per UFID microreflection/signalnoise."

      REVISION "200401240000Z"
      DESCRIPTION "Added cadantDPortMeasAppMcastPkts"

      REVISION "200312180000Z"
      DESCRIPTION "Added 10 BCM3214 counts to the cadantUPortMeasTable"

      REVISION "200312100000Z"
      DESCRIPTION " add more arp throttle counts. "

      REVISION "200309190000Z"
      DESCRIPTION " add more receive error counts to cadantEtherPhyMeasTable"

      REVISION "200308260000Z"
      DESCRIPTION " add error drop and filter drop counts to UPortMeas table"
 
      REVISION "200307300000Z"
      DESCRIPTION " Add support for DHCP packets dropped due to throttling. "

      REVISION "200205060000Z"
      DESCRIPTION " change cadantUFIDMeasBytsSGreedyDrop to cadantUFIDMeasPktsSGreedyDrop."

        ::= { cadEquipment 2 }

--========== Some General Definitions =============
--
DFIDIndex               ::= TEXTUAL-CONVENTION
        STATUS current
        DESCRIPTION
            "The 1's-based SFID"
        SYNTAX Unsigned32 (1.. 4294967295)

PktClassId              ::= TEXTUAL-CONVENTION
        STATUS current
        DESCRIPTION
            "Index assigned to packet classifier entry by the CMTS which is
             unique per service flow."
        SYNTAX Integer32 (1..65535)

SFIDIndex               ::= TEXTUAL-CONVENTION
        STATUS current
        DESCRIPTION
            "The 1's-based SFID"
        SYNTAX Integer32 (1..2147483647) -- (1..2^31)

UFIDIndex               ::= TEXTUAL-CONVENTION
        STATUS current
        DESCRIPTION
            "The 1's-based UFID"
        SYNTAX Integer32 (1..32768) -- (1..2^15)

SIDValue               ::= TEXTUAL-CONVENTION
        STATUS current
        DESCRIPTION
            "The 1's-based SID. 0 is used when there is
             no SID, such as for downstream flows."
        SYNTAX Integer32 (0..16384) -- (0..2^14)

TMSide                 ::= TEXTUAL-CONVENTION
        STATUS current
        DESCRIPTION
            "The Traffic Manager side 
             no SID, such as for downstream flows."
        SYNTAX INTEGER { tma(1), tmb(2) }

--
--==================HW Meas Group ==================--
--
cadantHWMeasGeneral OBJECT IDENTIFIER  ::= { cadHardwareMeasMib 1 }

cadantFabActualDepth    OBJECT-TYPE
        SYNTAX          Integer32
        MAX-ACCESS            read-only
        STATUS          current
        DESCRIPTION 
                " The current depth of the fabric."
        ::= { cadantHWMeasGeneral 1 }

cadantFabAvgDepth       OBJECT-TYPE
        SYNTAX          Integer32
        MAX-ACCESS            read-only
        STATUS          current
        DESCRIPTION 
                " The average depth of the fabric."
        ::= { cadantHWMeasGeneral 2 }

--======= U Port Meas Table ===============
--
cadantUPortMeasTable OBJECT-TYPE
        SYNTAX  SEQUENCE OF CadantUPortMeasEntry
        MAX-ACCESS      not-accessible
        STATUS  current
        DESCRIPTION
                " This table contains information relevant 
                  to D Card upstream channels."
        ::= { cadHardwareMeasMib 3 }


cadantUPortMeasEntry OBJECT-TYPE
        SYNTAX  CadantUPortMeasEntry
        MAX-ACCESS      not-accessible
        STATUS  current
        DESCRIPTION " "
        INDEX { cadantUPortMeasCardId, cadantUPortMeasPortId  }
        ::= { cadantUPortMeasTable  1 }

CadantUPortMeasEntry ::= SEQUENCE {
        cadantUPortMeasCardId              CardId,
        cadantUPortMeasPortId              PortId,
        cadantUPortMeasUcastFrms           Counter64,
        cadantUPortMeasMcastFrms           Counter64,
        cadantUPortMeasBcastFrms           Counter64,
        cadantUPortMeasUcastDataFrms       Counter64,
        cadantUPortMeasMcastDataFrms       Counter64,
        cadantUPortMeasBcastDataFrms       Counter64,
        cadantUPortMeasDiscardFrms         Counter64,
        cadantUPortMeasIfInOctets          Counter64,
        cadantUPortMeasIfInDataOctets      Counter64,
        cadantUPortMeasIfInUnknownProtos   Counter64,
        cadantUPortMeasAppMinusBWReqFrms   Counter64,
        cadantUPortMeasErroredFrms         Counter64,
        cadantUPortMeasFilteredFrms        Counter64,
        cadantUPortMeasBcastReqOpps        Counter64,
        cadantUPortMeasBcastReqColls       Counter64,
        cadantUPortMeasBcastReqNoEnergies  Counter64,
        cadantUPortMeasBcastReqRxPwr1s     Counter64,
        cadantUPortMeasBcastReqRxPwr2s     Counter64,
        cadantUPortMeasInitMaintOpps       Counter64,
        cadantUPortMeasInitMaintColls      Counter64,
        cadantUPortMeasInitMaintNoEnergies Counter64,
        cadantUPortMeasInitMaintRxPwr1s    Counter64,
        cadantUPortMeasInitMaintRxPwr2s    Counter64
}

cadantUPortMeasCardId OBJECT-TYPE
SYNTAX  CardId
        MAX-ACCESS      not-accessible
        STATUS  current
        DESCRIPTION 
                ""
        ::= { cadantUPortMeasEntry  1 }

cadantUPortMeasPortId OBJECT-TYPE
        SYNTAX  PortId
        MAX-ACCESS      not-accessible
        STATUS  current
        DESCRIPTION 
                ""
        ::= { cadantUPortMeasEntry  2 }

cadantUPortMeasUcastFrms OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " The aggregrate number of unicast frames received on this U channel,
              whether dropped or passed. This includes MAC packets."
        ::= { cadantUPortMeasEntry  3 }

cadantUPortMeasMcastFrms OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " The aggregrate number of multicast frames received on this U channel,
              whether dropped or passed. This includes MAC packets."
        ::= { cadantUPortMeasEntry  4 }

cadantUPortMeasBcastFrms OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " The aggregrate number of broadcast frames received on this U channel,
              whether dropped or passed. This includes MAC packets."
        ::= { cadantUPortMeasEntry  5 }

cadantUPortMeasUcastDataFrms OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " The aggregrate number of unicast frames received on this U channel,
              whether dropped or passed. This does not include MAC packets."
        ::= { cadantUPortMeasEntry  6 }

cadantUPortMeasMcastDataFrms OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " The aggregrate number of multicast frames received on this U channel,
              whether dropped or passed. This does not include MAC packets."
        ::= { cadantUPortMeasEntry  7 }

cadantUPortMeasBcastDataFrms OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " The aggregrate number of broadcast frames received on this U channel,
              whether dropped or passed. This does not include MAC packets."
        ::= { cadantUPortMeasEntry  8 }

cadantUPortMeasDiscardFrms OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " The aggregrate number of frames received on this U channel that were
              dropped for reasons other than ErrorFrms or FilterFrms."
        ::= { cadantUPortMeasEntry  9 }

cadantUPortMeasIfInOctets OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " The aggregrate number of octets received on this U channel.
              This includes MAC packets and the length of the MAC header."
        ::= { cadantUPortMeasEntry 10 }

cadantUPortMeasIfInDataOctets OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " The aggregrate number of octets received on this U channel.
          This does not include MAC packets or the length of the MAC header."
        ::= { cadantUPortMeasEntry 11 }

cadantUPortMeasIfInUnknownProtos OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " Aggregrate number of MAC frames with unknown protocol. This
                  count is neither mutually exclusive with cadantUPortMeasErroredFrms
                  nor cadantUPortMeasErroredFrms."
        ::= { cadantUPortMeasEntry 12 }

cadantUPortMeasAppMinusBWReqFrms OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " The number of (unicast) frames received by the software application
            which are not bandwidth request frames. "
        ::= { cadantUPortMeasEntry 13 }

cadantUPortMeasErroredFrms OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " The aggregrate number of packets received on this U channel that were
          received in error and dropped. This count is neither mutually exclusive
          with cadantUPortMeasIfInUnknownProtos nor cadantUPortMeasFilteredFrms."
        ::= { cadantUPortMeasEntry 15 }

cadantUPortMeasFilteredFrms OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " The aggregrate number of packets received on this U channel that were
          dropped due to a filter rule match and discard. This count is neither
          mutually exclusive with cadantUPortMeasIfInUnknownProtos nor
                  cadantUPortMeasErroredFrms."
        ::= { cadantUPortMeasEntry 16 }

cadantUPortMeasBcastReqOpps OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                "Broadcast contention request opportunity count"
        ::= { cadantUPortMeasEntry 17 }

cadantUPortMeasBcastReqColls OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                "Broadcast contention request opportunities with possible collisions count"
        ::= { cadantUPortMeasEntry 18 }

cadantUPortMeasBcastReqNoEnergies OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                "Broadcast contention request opportunities with no energy condition detected"
        ::= { cadantUPortMeasEntry 19 }

cadantUPortMeasBcastReqRxPwr1s OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                "Broadcast contention request opportunities with received power level between
                 power threshold 2 and power threshold 1"
        ::= { cadantUPortMeasEntry 20 }

cadantUPortMeasBcastReqRxPwr2s OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                "Broadcast contention request opportunities with received power level greater
                 than power threshold 2"
        ::= { cadantUPortMeasEntry 21 }

cadantUPortMeasInitMaintOpps OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                "Initial maintenance opportunities"
        ::= { cadantUPortMeasEntry 22 }

cadantUPortMeasInitMaintColls OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                "Initial maintenance opportunities with possible collision"
        ::= { cadantUPortMeasEntry 23 }

cadantUPortMeasInitMaintNoEnergies OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                "Initial maintenance opportunities with no energy detected"
        ::= { cadantUPortMeasEntry 24 }

cadantUPortMeasInitMaintRxPwr1s OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                "Initial maintenance opportunities with received power level between
                 power threshold 2 and power threshold 1"
        ::= { cadantUPortMeasEntry 25 }

cadantUPortMeasInitMaintRxPwr2s OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                "Initial maintenance opportunities with received power level greater
                 than power threshold 2"
        ::= { cadantUPortMeasEntry 26 }

--======= D Port Meas Table ===============
--

cadantDPortMeasTable OBJECT-TYPE
        SYNTAX  SEQUENCE OF CadantDPortMeasEntry
        MAX-ACCESS      not-accessible
        STATUS  current
        DESCRIPTION
                " This table contains information relevant 
                  to D Card downstream channels."
        ::= { cadHardwareMeasMib 4 }

cadantDPortMeasEntry OBJECT-TYPE
        SYNTAX  CadantDPortMeasEntry
        MAX-ACCESS      not-accessible
        STATUS  current
        DESCRIPTION " "
        INDEX { cadantDPortMeasCardId, cadantDPortMeasPortId  }
        ::= { cadantDPortMeasTable  1 }

CadantDPortMeasEntry ::= SEQUENCE {
        cadantDPortMeasCardId                       CardId,
        cadantDPortMeasPortId                       PortId,
        cadantDPortMeasIfOutOctets                  Counter64,
        cadantDPortMeasIfOutUcastPkts               Counter64,
        cadantDPortMeasIfOutMcastPkts               Counter64,
        cadantDPortMeasIfOutBcastPkts               Counter64,
        cadantDPortMeasIfOutDataOctets              Counter64,
        cadantDPortMeasIfOutUcastDataPkts           Counter64,
        cadantDPortMeasIfOutMcastDataPkts           Counter64,
        cadantDPortMeasIfOutBcastDataPkts           Counter64,
        cadantDPortMeasGotNoDMACs                   Counter64,
        cadantDPortMeasGotNoClasses                 Counter64,
        cadantDPortMeasSyncPkts                     Counter64,
        cadantDPortMeasAppUcastPkts                 Counter64,
        cadantDPortMeasAppMcastPkts                 Counter64,
        cadantDPortMeasIfOutTotalOctets             Counter64,
        cadantDPortMeasOfdmIfSpeed                  Gauge32,
        cadantDPortMeasOfdmHighestAvgBitsPerSubc    Unsigned32,
        cadantDPortMeasOfdmNumDataSubc              Unsigned32,
        cadantDPortMeasOfdmChanUtilization          Integer32
}

cadantDPortMeasCardId OBJECT-TYPE
        SYNTAX  CardId
        MAX-ACCESS      not-accessible
        STATUS  current
        DESCRIPTION 
                ""
        ::= { cadantDPortMeasEntry  1 }

cadantDPortMeasPortId OBJECT-TYPE
        SYNTAX  PortId
        MAX-ACCESS      not-accessible
        STATUS  current
        DESCRIPTION 
                ""
        ::= { cadantDPortMeasEntry  2 }

cadantDPortMeasIfOutOctets OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " Aggregrate number of data bytes sent on this D channel.
              This includes MAC mgmt messages and the length of the
              MAC header."
        ::= { cadantDPortMeasEntry  3 }

cadantDPortMeasIfOutUcastPkts OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " Aggregrate number of unicast data packets sent on this D channel.
              This includes MAC mgmt messages."
        ::= { cadantDPortMeasEntry  4 }

cadantDPortMeasIfOutMcastPkts OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " Aggregrate number of multicast data packets sent on this D channel.
              This includes MAC mgmt messages."
        ::= { cadantDPortMeasEntry  5 }

cadantDPortMeasIfOutBcastPkts OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " Aggregrate number of broadcast data packets sent on this D channel.
              This includes MAC mgmt messages."
        ::= { cadantDPortMeasEntry  6 }

cadantDPortMeasIfOutDataOctets OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " Aggregrate number of data bytes sent on this D channel.
              This does not include MAC mgmt bytes."
        ::= { cadantDPortMeasEntry  7 }

cadantDPortMeasIfOutUcastDataPkts OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " Aggregrate number of unicast data packets sent on this D channel.
              This does not include MAC mgmt messages."
        ::= { cadantDPortMeasEntry  8 }

cadantDPortMeasIfOutMcastDataPkts OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " Aggregrate number of multicast data packets sent on this D channel.
              This does not include MAC mgmt messages."
        ::= { cadantDPortMeasEntry  9 }

cadantDPortMeasIfOutBcastDataPkts OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " Aggregrate number of broadcast data packets sent on this D channel.
              This does not include MAC mgmt messages."
        ::= { cadantDPortMeasEntry 10 }

cadantDPortMeasGotNoDMACs OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " Aggregrate number of ???"
        ::= { cadantDPortMeasEntry 11 }

cadantDPortMeasGotNoClasses OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " Aggregrate number of ???."
        ::= { cadantDPortMeasEntry 12 }

cadantDPortMeasSyncPkts OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " Aggregrate number of sync. frames sent on this D channel."
        ::= { cadantDPortMeasEntry 13 }

cadantDPortMeasAppUcastPkts OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " Aggregrate number of unicast DOCSIS Mac mgmt messages
            sent by application software. "
        ::= { cadantDPortMeasEntry 14 }

cadantDPortMeasAppMcastPkts OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " Aggregrate number of multicast DOCSIS Mac mgmt messages
            sent by application software. "
        ::= { cadantDPortMeasEntry 15 }

cadantDPortMeasIfOutTotalOctets OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " Aggregrate number of octets sent by application software. "
        ::= { cadantDPortMeasEntry 16 }

cadantDPortMeasOfdmIfSpeed OBJECT-TYPE
        SYNTAX  Gauge32
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                "Downstream OFDM channel interface speed."
        ::= { cadantDPortMeasEntry 17 }

cadantDPortMeasOfdmHighestAvgBitsPerSubc OBJECT-TYPE
        SYNTAX  Unsigned32
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                "Highest average bits per subcarrier among all the data profiles of the downstream OFDM channel."
        ::= { cadantDPortMeasEntry 18 }

cadantDPortMeasOfdmNumDataSubc OBJECT-TYPE
        SYNTAX  Unsigned32
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                "The number of data subcarrier of the downstream OFDM channel."
        ::= { cadantDPortMeasEntry 19 }

cadantDPortMeasOfdmChanUtilization OBJECT-TYPE
        SYNTAX       Integer32 (0..100)
        UNITS        "percent"
        MAX-ACCESS   read-only
        STATUS       current
        DESCRIPTION
             "The utilization of the downstream OFDM channel."
        ::= { cadantDPortMeasEntry 20 }

--======= UFID Meas Table ===============--

cadantUFIDMeasTable OBJECT-TYPE
        SYNTAX  SEQUENCE OF CadantUFIDMeasEntry
        MAX-ACCESS      not-accessible
        STATUS  current
        DESCRIPTION
                " "
        ::= { cadHardwareMeasMib 6 }

cadantUFIDMeasEntry OBJECT-TYPE
        SYNTAX  CadantUFIDMeasEntry
        MAX-ACCESS      not-accessible
        STATUS  current
        DESCRIPTION " "
        INDEX { ifIndex, cadantUFIDMeasSID }
        ::= { cadantUFIDMeasTable  1 }

CadantUFIDMeasEntry ::= SEQUENCE {

        cadantUFIDMeasSID                      SIDValue,
        cadantUFIDMeasPktsSGreedyDrop          Counter64,
        cadantUFIDMeasBytsOtherDrop            Counter64,
        cadantUFIDMeasBytsArrived              Counter64,
        cadantUFIDMeasPktsArrived              Counter64, 
        cadantUFIDMeasSIDCorrecteds            Counter64,
        cadantUFIDMeasSIDUnerroreds            Counter64,
        cadantUFIDMeasSIDUnCorrecteds          Counter64,
        cadantUFIDMeasSIDNoUniqueWordDetecteds Counter64,
        cadantUFIDMeasSIDCollidedBursts        Counter64, 
        cadantUFIDMeasSIDNoEnergyDetecteds     Counter64,
        cadantUFIDMeasSIDLengthErrors          Counter64,
        cadantUFIDMeasSIDMACErrors             Counter64,
        cadantUFIDMeasMacAddress               MacAddress,
        cadantUFIDMeasSCN                      DisplayString,
        cadantUFIDMeasSFID                     SFIDIndex,
        cadantUFIDMeasPHSUnknowns              Counter64,
        cadantUFIDMeasFragPkts                 Counter64,
        cadantUFIDMeasIncompletePkts           Counter64,
        cadantUFIDMeasConcatBursts             Counter64,
        cadantUFIDMeasSIDSignalNoise           TenthdB,
        cadantUFIDMeasSIDMicroreflections      Integer32,
        cadantUFIDMeasSIDHCSErrors             Counter64,
        cadantUFIDMeasSIDCRCErrors             Counter64,
        cadantUFIDMeasUFIDIndex                UFIDIndex,
        cadantUFIDMeasGateID                   Unsigned32,
        cadantUFIDMeasSIDMacIfIndex            InterfaceIndex,
        cadantUFIDMeasSIDBonded                TruthValue,
        cadantUFIDMeasCcfStatsSgmtValids       Counter32,
        cadantUFIDMeasCcfStatsSgmtLost         Counter32,
        cadantUFIDMeasCcfStatsSgmtDrop         Counter32
}


cadantUFIDMeasSID OBJECT-TYPE
        SYNTAX  SIDValue
        MAX-ACCESS      not-accessible
        STATUS  current
        DESCRIPTION 
                " The 14 bit (SID)."
        ::= { cadantUFIDMeasEntry  3 }

cadantUFIDMeasPktsSGreedyDrop OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " The aggregrate number of Super Greedy pkts dropped for this UFID for
              this MAC layer."
        ::= { cadantUFIDMeasEntry  4 }

cadantUFIDMeasBytsOtherDrop OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " The aggregrate number of bytes dropped for this UFID for
              this MAC layer for any other reason than Super Greedy."
        ::= { cadantUFIDMeasEntry  5 }

cadantUFIDMeasBytsArrived OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " The aggregrate number of bytes that arrived for this UFID for
              this MAC layer."
        ::= { cadantUFIDMeasEntry  6 }

cadantUFIDMeasPktsArrived OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " The aggregrate number of packets that arrived for this UFID for
              this MAC layer."
        ::= { cadantUFIDMeasEntry  7 }

cadantUFIDMeasSIDCorrecteds OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " The aggregrate number of bytes that had errors and were corrected
              for this UFID for this MAC layer."
        ::= { cadantUFIDMeasEntry  8 }

cadantUFIDMeasSIDUnerroreds OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " The aggregrate number of bytes that had no errors
              for this UFID for this MAC layer."
        ::= { cadantUFIDMeasEntry  9 }

cadantUFIDMeasSIDUnCorrecteds OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " The aggregrate number of bytes that had errors and were not
              corrected for this UFID for this MAC layer."
        ::= { cadantUFIDMeasEntry 10 }

cadantUFIDMeasSIDNoUniqueWordDetecteds OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " The aggregrate number of bytes allocated for this UFID in which
              no unique code word was detected for this UFID for this MAC layer."
        ::= { cadantUFIDMeasEntry 11 }

cadantUFIDMeasSIDCollidedBursts OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " The aggregrate number of bytes allocated for this UFID that had
              burst errors in their slots for this UFID for this MAC layer."
        ::= { cadantUFIDMeasEntry 12 }

cadantUFIDMeasSIDNoEnergyDetecteds OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " The aggregrate number of bytes allocated for this UFID that had
              no energy detected in their slots for this UFID for this MAC layer."
        ::= { cadantUFIDMeasEntry 13 }

cadantUFIDMeasSIDLengthErrors OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " The aggregrate number of bytes allocated for this UFID that had
              no length errors in their slots for this UFID for this MAC layer."
        ::= { cadantUFIDMeasEntry 14 }

cadantUFIDMeasSIDMACErrors OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " The aggregrate number of bytes allocated for this UFID that had
              MAC errors in their slots for this UFID for this MAC layer."
        ::= { cadantUFIDMeasEntry 15 }
cadantUFIDMeasMacAddress OBJECT-TYPE
        SYNTAX  MacAddress
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " The MAC address of the CM this flow is associated with."
        ::= { cadantUFIDMeasEntry 17 }

cadantUFIDMeasSCN OBJECT-TYPE
        SYNTAX  DisplayString
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " The Service Class Name for this flow."
        ::= { cadantUFIDMeasEntry 18 }

cadantUFIDMeasSFID OBJECT-TYPE
        SYNTAX  SFIDIndex
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " The SFID this UFID(SID) is for."
        ::= { cadantUFIDMeasEntry 19 }

cadantUFIDMeasPHSUnknowns OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                "refer to docsQosServiceFlowPHSUnknowns"
        ::= { cadantUFIDMeasEntry 20 }

cadantUFIDMeasFragPkts OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                "refer to docsQosUpstreamFragPkts"
        ::= { cadantUFIDMeasEntry 21 }

cadantUFIDMeasIncompletePkts OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                "refer to docsQosUpstreamIncompletePkts"
        ::= { cadantUFIDMeasEntry 22 }

cadantUFIDMeasConcatBursts OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                "refer to docsQosUpstreamConcatBursts"
        ::= { cadantUFIDMeasEntry 23 }

cadantUFIDMeasSIDSignalNoise OBJECT-TYPE
        SYNTAX  TenthdB
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                "refer to docsIfCmtsCmStatusSignalNoise"
        ::= { cadantUFIDMeasEntry 24 }

cadantUFIDMeasSIDMicroreflections OBJECT-TYPE
        SYNTAX  Integer32
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                "refer to docsIfCmtsCmStatusMicroreflections"
        ::= { cadantUFIDMeasEntry 25 }

cadantUFIDMeasSIDHCSErrors OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                "The number of MAC HCS errors seen for this SID."
        ::= { cadantUFIDMeasEntry 26 }

cadantUFIDMeasSIDCRCErrors OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                "The number of MAC CRC errors seen for this SID."
        ::= { cadantUFIDMeasEntry 27 }

cadantUFIDMeasUFIDIndex OBJECT-TYPE
        SYNTAX  UFIDIndex
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " The 15 bit (UFID)."
        ::= { cadantUFIDMeasEntry 28 }

cadantUFIDMeasGateID OBJECT-TYPE
        SYNTAX  Unsigned32
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " The DQoS or PCMM gate ID corresponding to the flow,
                  A zero in this field indicates no gate is associated with the flow."
        ::= { cadantUFIDMeasEntry  29 }

cadantUFIDMeasSIDMacIfIndex OBJECT-TYPE
        SYNTAX  InterfaceIndex
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " The cable Mac domain ifIndex the SID is associated with."
        ::= { cadantUFIDMeasEntry  30 }

cadantUFIDMeasSIDBonded OBJECT-TYPE
        SYNTAX  TruthValue
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " This object indicates whether a SID is associated with 
                  a CCF service flow."
        ::= { cadantUFIDMeasEntry  31 }

cadantUFIDMeasCcfStatsSgmtValids OBJECT-TYPE
        SYNTAX  Counter32
		UNITS	"segments"
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
			"This attribute contains the number of segments counted
			on this service flow regardless of whether the
			fragment was correctly reassembled into valid packets.
			Discontinuities in the value of this counter can
			occur at reinitialization of the managed system."
        ::= { cadantUFIDMeasEntry 32 }

cadantUFIDMeasCcfStatsSgmtLost OBJECT-TYPE
        SYNTAX  Counter32
		UNITS	"segments"
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
			"This attribute counts the number of segments which
			the CMTS segment reassembly function determines were
			lost. Discontinuities in the value of this counter
			can occur at reinitialization of the managed system."
        ::= { cadantUFIDMeasEntry 33 }

cadantUFIDMeasCcfStatsSgmtDrop OBJECT-TYPE
        SYNTAX  Counter32
		UNITS	"segments"
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
			"This attribute counts the number of segments which
			the CMTS segment reassembly function determines were
			dropped. Discontinuities in the value of this counter
			can occur at reinitialization of the managed system."
        ::= { cadantUFIDMeasEntry  34 }


--
--================== EtherPhys Meas Table ==============================-
--

cadantEtherPhyMeasTable OBJECT-TYPE
        SYNTAX  SEQUENCE OF CadantEtherPhyMeasEntry
        MAX-ACCESS      not-accessible
        STATUS  current
        DESCRIPTION
                " "
        ::= { cadHardwareMeasMib 10 }

cadantEtherPhyMeasEntry OBJECT-TYPE
        SYNTAX  CadantEtherPhyMeasEntry
        MAX-ACCESS      not-accessible
        STATUS  current
        DESCRIPTION " "
        INDEX { cadantEtherPhyMeasCardId, cadantEtherPhyMeasPortId }
        ::= { cadantEtherPhyMeasTable  1 }

CadantEtherPhyMeasEntry ::= SEQUENCE {
        cadantEtherPhyMeasCardId         CardId,
        cadantEtherPhyMeasPortId         PortId,

        cadantEtherPhyMeasRxOctOK        Counter64,
        cadantEtherPhyMeasRxUniOK        Counter64,
        cadantEtherPhyMeasRxMultiOK      Counter64,
        cadantEtherPhyMeasRxBroadOK      Counter64,
        cadantEtherPhyMeasRxOverflow     Counter64,
        cadantEtherPhyMeasRxNormAlign    Counter64,
        cadantEtherPhyMeasRxNormCRC      Counter64,
        cadantEtherPhyMeasRxLongOK       Counter64,
        cadantEtherPhyMeasRxLongCRC      Counter64,
        cadantEtherPhyMeasRxFalsCRS      Counter64,
        cadantEtherPhyMeasRxSymbolErrors Counter64,
        cadantEtherPhyMeasRxPause        Counter64,
        cadantEtherPhyMeasTxOctOK        Counter64,
        cadantEtherPhyMeasTxUniOK        Counter64, 
        cadantEtherPhyMeasTxMultiOK      Counter64, 
        cadantEtherPhyMeasTxBroadOK      Counter64,
        cadantEtherPhyMeasTxScol         Counter64,
        cadantEtherPhyMeasTxMcol         Counter64,
        cadantEtherPhyMeasTxDeferred     Counter64,
        cadantEtherPhyMeasTxLcol         Counter64,
        cadantEtherPhyMeasTxCcol         Counter64,
        cadantEtherPhyMeasTxErr          Counter64,
        cadantEtherPhyMeasTxPause        Counter64,
        cadantEtherPhyMeasRxShortOK      Counter64,
        cadantEtherPhyMeasRxShortCRC     Counter64,
        cadantEtherPhyMeasRxRunt         Counter64,
        cadantEtherPhyMeasRxOctBad       Counter64
}

cadantEtherPhyMeasCardId OBJECT-TYPE
        SYNTAX  CardId
        MAX-ACCESS      not-accessible
        STATUS  current
        DESCRIPTION
                ""
        ::= { cadantEtherPhyMeasEntry  1 }

cadantEtherPhyMeasPortId OBJECT-TYPE
        SYNTAX  PortId
        MAX-ACCESS      not-accessible
        STATUS  current
        DESCRIPTION
                ""
        ::= { cadantEtherPhyMeasEntry  2 }

cadantEtherPhyMeasRxOctOK OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " ."
        ::= { cadantEtherPhyMeasEntry  3 }

cadantEtherPhyMeasRxUniOK OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " ."
        ::= { cadantEtherPhyMeasEntry  4 }

cadantEtherPhyMeasRxMultiOK OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " ."
        ::= { cadantEtherPhyMeasEntry  5 }

cadantEtherPhyMeasRxBroadOK OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " ."
        ::= { cadantEtherPhyMeasEntry  6 }

cadantEtherPhyMeasRxOverflow OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " ."
        ::= { cadantEtherPhyMeasEntry  7 }

cadantEtherPhyMeasRxNormAlign OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " ."
        ::= { cadantEtherPhyMeasEntry  8 }

cadantEtherPhyMeasRxNormCRC OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " ."
        ::= { cadantEtherPhyMeasEntry  9 }

cadantEtherPhyMeasRxLongOK OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " ."
        ::= { cadantEtherPhyMeasEntry 10 }

cadantEtherPhyMeasRxLongCRC OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " ."
        ::= { cadantEtherPhyMeasEntry 11 }

cadantEtherPhyMeasRxFalsCRS OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " ."
        ::= { cadantEtherPhyMeasEntry 12 }

cadantEtherPhyMeasRxSymbolErrors OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " ."
        ::= { cadantEtherPhyMeasEntry 13 }

cadantEtherPhyMeasRxPause OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " ."
        ::= { cadantEtherPhyMeasEntry 14 }

cadantEtherPhyMeasTxOctOK OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " ."
        ::= { cadantEtherPhyMeasEntry 15 }

cadantEtherPhyMeasTxUniOK OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " ."
        ::= { cadantEtherPhyMeasEntry 16 }

cadantEtherPhyMeasTxMultiOK OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " ."
        ::= { cadantEtherPhyMeasEntry 17 }

cadantEtherPhyMeasTxBroadOK OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " ."
        ::= { cadantEtherPhyMeasEntry 18 }

cadantEtherPhyMeasTxScol OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " ."
        ::= { cadantEtherPhyMeasEntry 19 }

cadantEtherPhyMeasTxMcol OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " ."
        ::= { cadantEtherPhyMeasEntry 20 }

cadantEtherPhyMeasTxDeferred OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " ."
        ::= { cadantEtherPhyMeasEntry 21 }

cadantEtherPhyMeasTxLcol OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " ."
        ::= { cadantEtherPhyMeasEntry 22 }

cadantEtherPhyMeasTxCcol OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " ."
        ::= { cadantEtherPhyMeasEntry 23 }

cadantEtherPhyMeasTxErr OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " ."
        ::= { cadantEtherPhyMeasEntry 24 }

cadantEtherPhyMeasTxPause OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " ."
        ::= { cadantEtherPhyMeasEntry 25 }

cadantEtherPhyMeasRxShortOK OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " ."
        ::= { cadantEtherPhyMeasEntry 26 }

cadantEtherPhyMeasRxShortCRC OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " ."
        ::= { cadantEtherPhyMeasEntry 27 }

cadantEtherPhyMeasRxRunt OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " ."
        ::= { cadantEtherPhyMeasEntry 28 }

cadantEtherPhyMeasRxOctBad OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " ."
        ::= { cadantEtherPhyMeasEntry 29 }



--
--================== DFID Meas Table ==============================-
--

cadDFIDMeasTable OBJECT-TYPE
        SYNTAX  SEQUENCE OF CadDFIDMeasEntry
        MAX-ACCESS      not-accessible
        STATUS  current
        DESCRIPTION
                "This table contains DFID-specific counts."
        ::= { cadHardwareMeasMib 14 }

cadDFIDMeasEntry OBJECT-TYPE
        SYNTAX  CadDFIDMeasEntry
        MAX-ACCESS      not-accessible
        STATUS  current
        DESCRIPTION " "
        INDEX { ifIndex, cadDFIDMeasIndex }
        ::= { cadDFIDMeasTable  1 }

CadDFIDMeasEntry ::= SEQUENCE {
        cadDFIDMeasIndex           SFIDIndex,
        cadDFIDMeasBytsArrived     Counter64,
        cadDFIDMeasPktsArrived     Counter64,
        cadDFIDMeasBytsDropped     Counter64,
        cadDFIDMeasPktsDropped     Counter64,
        cadDFIDMeasBytsUnkDropped  Counter64,
        cadDFIDMeasDFID            DFIDIndex,
        cadDFIDMeasPHSUnknowns     Counter64,
        cadDFIDMeasMacAddress      MacAddress,
        cadDFIDMeasSCN             DisplayString,
        cadDFIDMeasPolicedDelayPkts Counter64,
	cadDFIDMeasGateID          Unsigned32
}


cadDFIDMeasIndex OBJECT-TYPE
        SYNTAX  SFIDIndex
        MAX-ACCESS      not-accessible
        STATUS  current
        DESCRIPTION
                " The SFID these DFID counts are for."
        ::= { cadDFIDMeasEntry  3 }

cadDFIDMeasBytsArrived OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " The aggregrate number of bytes arriving to go out,
              but not necessarily transmitted."
        ::= { cadDFIDMeasEntry  4 }

cadDFIDMeasPktsArrived OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " The aggregrate number of packets arriving to go out,
              but not necessarily transmitted."
        ::= { cadDFIDMeasEntry  5 }

cadDFIDMeasBytsDropped OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " The aggregrate number of bytes dropped."
        ::= { cadDFIDMeasEntry  6 }

cadDFIDMeasPktsDropped OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " The aggregrate number of packets dropped."
        ::= { cadDFIDMeasEntry  7 }

cadDFIDMeasBytsUnkDropped OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " The aggregrate number of bytes dropped due to unknown DMAC."
        ::= { cadDFIDMeasEntry  8 }

cadDFIDMeasDFID OBJECT-TYPE
        SYNTAX  DFIDIndex
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " The DFID."
        ::= { cadDFIDMeasEntry  9 }

cadDFIDMeasPHSUnknowns OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                "refer to docsQosServiceFlowPHSUnknowns"
        ::= { cadDFIDMeasEntry 10 }

cadDFIDMeasMacAddress OBJECT-TYPE
        SYNTAX  MacAddress
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " The MAC address of the CM this flow is associated with."
        ::= { cadDFIDMeasEntry 11 }

cadDFIDMeasSCN OBJECT-TYPE
        SYNTAX  DisplayString
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                " The Service Class Name for this flow."
        ::= { cadDFIDMeasEntry 12 }

cadDFIDMeasPolicedDelayPkts OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                "refer to docsQosServiceFlowPolicedDelayPkts"
        ::= { cadDFIDMeasEntry 13 }

cadDFIDMeasGateID OBJECT-TYPE
        SYNTAX  Unsigned32
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " The DQoS or PCMM gate ID corresponding to the flow,
                  A zero in this field indicates no gate is associated with the flow."
        ::= { cadDFIDMeasEntry  14 }


--
--================= Classifier Match Count Table ==============================-
--

cadQosPktClassMeasTable OBJECT-TYPE
        SYNTAX  SEQUENCE OF CadQosPktClassMeasEntry
        MAX-ACCESS      not-accessible
        STATUS  current
        DESCRIPTION
                " This table contains just one data member: cadQosPktClassMeasPkts,
              which is equivalent to docsQosPktClassPkts in qos-draft-04."
        ::= { cadHardwareMeasMib 16 }

cadQosPktClassMeasEntry OBJECT-TYPE
        SYNTAX  CadQosPktClassMeasEntry
        MAX-ACCESS      not-accessible
        STATUS  current
        DESCRIPTION " "
        INDEX { cadQosPktClassMeasIfIndex,
              cadQosPktClassMeasSFID,
              cadQosPktClassMeasPktClassId }
        ::= { cadQosPktClassMeasTable 1 }

CadQosPktClassMeasEntry ::= SEQUENCE {
        cadQosPktClassMeasIfIndex    InterfaceIndex,
        cadQosPktClassMeasSFID       SFIDIndex,
        cadQosPktClassMeasPktClassId PktClassId,
        cadQosPktClassMeasPkts       Counter64
}

cadQosPktClassMeasIfIndex OBJECT-TYPE
        SYNTAX  InterfaceIndex
        MAX-ACCESS      not-accessible
        STATUS  current
        DESCRIPTION
                " The ifIndex of ifType 127 for this classifier."
        ::= { cadQosPktClassMeasEntry 1 }

cadQosPktClassMeasSFID OBJECT-TYPE
        SYNTAX  SFIDIndex
        MAX-ACCESS      not-accessible
        STATUS  current
        DESCRIPTION
                " The Service Flow ID this classifier is for."
        ::= { cadQosPktClassMeasEntry 2 }

cadQosPktClassMeasPktClassId OBJECT-TYPE
        SYNTAX  PktClassId
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " The ID of this classifier, which only need be unique for a given Service Flow ID."
        ::= { cadQosPktClassMeasEntry 3 }

cadQosPktClassMeasPkts OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " The number of packets that have been classified using this classifier on this flow."
        ::= { cadQosPktClassMeasEntry 4 }


--
--=========== Interface counts, to support If and IfX tables
--
cadIfMeasTable OBJECT-TYPE
        SYNTAX  SEQUENCE OF CadIfMeasEntry
        MAX-ACCESS      not-accessible
        STATUS  current
        DESCRIPTION
                " This table is designed to concurrently support the counters
            defined in the ifTable and the ifXTable. Every row that appears
            in this table should have a corresponding row in both the ifTable
            and the ifXTable. However, not every row in the ifTable and
            ifXTable will appear in this table."
        ::= { cadHardwareMeasMib 18 }

cadIfMeasEntry OBJECT-TYPE
        SYNTAX  CadIfMeasEntry
        MAX-ACCESS      not-accessible
        STATUS  current
        DESCRIPTION ""
        INDEX { ifIndex }
        ::= { cadIfMeasTable 1 }

CadIfMeasEntry ::= SEQUENCE {
        cadIfInOctets              Counter64,
        cadIfInUcastPkts           Counter64,
        cadIfInMulticastPkts       Counter64,
        cadIfInBroadcastPkts       Counter64,
        cadIfInDiscards            Counter64,
        cadIfInErrors              Counter64,
        cadIfInUnknownProtos       Counter64,
        cadIfOutOctets             Counter64,
        cadIfOutUcastPkts          Counter64,
        cadIfOutMulticastPkts      Counter64,
        cadIfOutBroadcastPkts      Counter64,
        cadIfOutDiscards           Counter64,
        cadIfOutErrors             Counter64
}

cadIfInOctets OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " See the IF-MIB's corresponding object's DESCRIPTION for a
            description of this object."
        ::= { cadIfMeasEntry  1 }

cadIfInUcastPkts OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " See the IF-MIB's corresponding object's DESCRIPTION for a
            description of this object."
        ::= { cadIfMeasEntry  2 }

cadIfInMulticastPkts OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " See the IF-MIB's corresponding object's DESCRIPTION for a
            description of this object."
        ::= { cadIfMeasEntry  3 }

cadIfInBroadcastPkts OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " See the IF-MIB's corresponding object's DESCRIPTION for a
            description of this object."
        ::= { cadIfMeasEntry  4 }

cadIfInDiscards OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " See the IF-MIB's corresponding object's DESCRIPTION for a
            description of this object."
        ::= { cadIfMeasEntry  5 }

cadIfInErrors OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " See the IF-MIB's corresponding object's DESCRIPTION for a
            description of this object."
        ::= { cadIfMeasEntry  6 }

cadIfInUnknownProtos OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " See the IF-MIB's corresponding object's DESCRIPTION for a
            description of this object."
        ::= { cadIfMeasEntry  7 }

cadIfOutOctets OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " See the IF-MIB's corresponding object's DESCRIPTION for a
            description of this object."
        ::= { cadIfMeasEntry  8 }

cadIfOutUcastPkts OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " See the IF-MIB's corresponding object's DESCRIPTION for a
            description of this object."
        ::= { cadIfMeasEntry  9 }

cadIfOutMulticastPkts OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " See the IF-MIB's corresponding object's DESCRIPTION for a
            description of this object."
        ::= { cadIfMeasEntry 10 }

cadIfOutBroadcastPkts OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " See the IF-MIB's corresponding object's DESCRIPTION for a
            description of this object."
        ::= { cadIfMeasEntry 11 }

cadIfOutDiscards OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " See the IF-MIB's corresponding object's DESCRIPTION for a
            description of this object."
        ::= { cadIfMeasEntry 12 }

cadIfOutErrors OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                " See the IF-MIB's corresponding object's DESCRIPTION for a
            description of this object."
        ::= { cadIfMeasEntry 13 }


--
--======= D Card Meas Table ===============
--

cadDCardMeasTable OBJECT-TYPE
        SYNTAX  SEQUENCE OF CadDCardMeasEntry
        MAX-ACCESS      not-accessible
        STATUS  current
        DESCRIPTION
                " This table contains information relevant 
                  to D Card counts."
        ::= { cadHardwareMeasMib 20 }

cadDCardMeasEntry OBJECT-TYPE
        SYNTAX  CadDCardMeasEntry
        MAX-ACCESS      not-accessible
        STATUS  current
        DESCRIPTION " "
        INDEX { cadDCardMeasCardId }
        ::= { cadDCardMeasTable 1 }

CadDCardMeasEntry ::= SEQUENCE {
            cadDCardMeasCardId           CardId,
            cadDCardIpInReceives         Counter64,
            cadDCardIpInHdrErrors        Counter64,
            cadDCardIpInAddrErrors       Counter64,
            cadDCardDhcpThrottleDropPkts Counter64,
            cadDCardArpThrottleDropPkts  Counter64,
            cadDCardDhcpV6ThrottleDropPkts Counter64,
            cadDCardNdThrottleDropPkts   Counter64,
            cadDCardIgmpThrottleDropPkts Counter64
}

cadDCardMeasCardId OBJECT-TYPE
        SYNTAX  CardId
        MAX-ACCESS      not-accessible
        STATUS  current
        DESCRIPTION 
                ""
        ::= { cadDCardMeasEntry  1 }

cadDCardIpInReceives OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                "The contribution to ipInRecevies for this
            particular D Card."
        ::= { cadDCardMeasEntry  2 }

cadDCardIpInHdrErrors OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                "The contribution to ipInHdrErrors for this
            particular D Card."
        ::= { cadDCardMeasEntry  3 }

cadDCardIpInAddrErrors OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION 
                "The contribution to ipInAddrErrors for this
            particular D Card."
        ::= { cadDCardMeasEntry  4 }

cadDCardDhcpThrottleDropPkts OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                "The number of dropped DHCP requests for this D Card."
        ::= { cadDCardMeasEntry  5 }

cadDCardArpThrottleDropPkts OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                "The number of dropped ARP requests for this D Card."
        ::= { cadDCardMeasEntry  6 }

cadDCardDhcpV6ThrottleDropPkts OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                "The number of dropped IPV6 DHCP requests for this D Card."
        ::= { cadDCardMeasEntry  7 }

cadDCardNdThrottleDropPkts OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                "The number of dropped IPV6 ND requests for this D Card."
        ::= { cadDCardMeasEntry  8 }

cadDCardIgmpThrottleDropPkts OBJECT-TYPE
        SYNTAX  Counter64
        MAX-ACCESS      read-only
        STATUS  current
        DESCRIPTION
                "The number of dropped IGMP messages for this UCAM."
        ::= { cadDCardMeasEntry  9 }

--
-- Interface Utilization Table
--

cadInterfaceUtilizationTable  OBJECT-TYPE
        SYNTAX      SEQUENCE OF CadInterfaceUtilizationEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Reports utilization statistics for attached interfaces."
        ::= { cadHardwareMeasMib 23 }

cadInterfaceUtilizationEntry OBJECT-TYPE
        SYNTAX      CadInterfaceUtilizationEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Utilization statistics for a single interface. An entry exists in this table for each
             ifEntry with an ifType equal to docsCableDownstreamInterface (128), 
             docsCableUpstreamInterface (129), docsCableUpstreamChannel (205), ethernet(6), or 
             gigabitEthernet(117)."
        INDEX { ifIndex, cadInterfaceUtilizationDirection }
        ::= { cadInterfaceUtilizationTable 1 }

CadInterfaceUtilizationEntry ::= SEQUENCE {
            cadInterfaceUtilizationDirection  CadIfDirection,
            cadInterfaceUtilizationPercentage Integer32,
            cadInterfaceUtilizationAvgContSlots Integer32,
            cadInterfaceHighResUtilizationPercentage Integer32,
            cadInterfaceIntervalOctetsForwarded Counter64
        }

cadInterfaceUtilizationDirection OBJECT-TYPE
        SYNTAX       CadIfDirection
        MAX-ACCESS   not-accessible
        STATUS       current
        DESCRIPTION
             "The direction of flow this utilization is for. Cable upstream interfaces
                          will only have a value of 'in' for this object. Likewise, cable downstream
                          interfaces will only hav a value of 'out' for this object. Full-duplex interfaces,
                          such as fastEthernet and gigabitEthernet interfaces, will have both 'in' and 'out'
                          rows."
        ::= { cadInterfaceUtilizationEntry 1 }

cadInterfaceUtilizationPercentage OBJECT-TYPE
        SYNTAX       Integer32 (0..100)
        UNITS        "percent"
        MAX-ACCESS   read-only
        STATUS       current
        DESCRIPTION
             "The calculated and truncated utilization index for this interface, accurate 
              as of the most recent docsIfCmtsChannelUtilizationInterval."
        ::= { cadInterfaceUtilizationEntry 2 }

cadInterfaceUtilizationAvgContSlots OBJECT-TYPE
        SYNTAX       Integer32 (0..100)
        UNITS        "percent"
        MAX-ACCESS   read-only
        STATUS       current
        DESCRIPTION 
            "Applicable for ifType of docsCableUpstreamChannel (205) only.
                         The average percentage of contention mini-slots for upstream channel. 
                         This ratio is calculated the most recent utilization interval.

              Formula:
              Upstream contention mini-slots utilization = 
              (100 * ((contention mini-slots ) / (total mini-slots))"
        ::= { cadInterfaceUtilizationEntry 3 }

cadInterfaceHighResUtilizationPercentage OBJECT-TYPE
        SYNTAX       Integer32 (0..10000)
        UNITS        "Hundredth of a percent"
        MAX-ACCESS   read-only
        STATUS       current
        DESCRIPTION
             "The calculated and truncated utilization index for this interface, 
              accurate (to 0.01% resolution) as of the most recent docsIfCmtsChannelUtilizationInterval."
        ::= { cadInterfaceUtilizationEntry 4 }

cadInterfaceIntervalOctetsForwarded OBJECT-TYPE
        SYNTAX       Counter64
        MAX-ACCESS   read-only
        STATUS       current
        DESCRIPTION
             "The number of octets forwarded since the most recent docsIfCmtsChannelUtilizationInterval. 
              Note that this count will only apply to the following interface types: Ethernet, 
              Link-Aggregate. For all other interface types this value will display 0"
        ::= { cadInterfaceUtilizationEntry 5 }

--
-- FFT Status Table removed
--
-- cadFftUpstreamChannelTable  OBJECT-TYPE
--        ::= { cadHardwareMeasMib 24 }


--
-- IP filter match counter clear table
--
cadSubMgtPktFilterExtTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF CadSubMgtPktFilterExtEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "This table augments the docsSubMgtPktFilterTable. In its
                        current form, it is used to clear docsSubMgtPktFilterMatches
                        and keep track of the change."
        ::= { cadHardwareMeasMib 25 }

cadSubMgtPktFilterExtEntry OBJECT-TYPE
        SYNTAX      CadSubMgtPktFilterExtEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "For every docsSubmgt3FilterGrpEntry, there is a matching
                        cadSubMgtPktFilterExtEntry."
        AUGMENTS { docsSubmgt3FilterGrpEntry }
        ::= { cadSubMgtPktFilterExtTable 1 }

CadSubMgtPktFilterExtEntry ::= SEQUENCE {
            cadSubMgtPktFilterMatchesReset   TruthValue,
            cadSubMgtPktFilterLastChanged    TimeStamp,
            cadSubMgtPktFilterCaptureEnabled TruthValue
        }

cadSubMgtPktFilterMatchesReset OBJECT-TYPE
        SYNTAX       TruthValue
        MAX-ACCESS   read-write
        STATUS       current
        DESCRIPTION
             "This object always return false(2) when read. If the value
              false(2) is assigned to this object, no action is taken.
              However, if this object it set to the value true(1), the
              corresponding docsSubMgtPktFilterMatches counter object is
              set to 0 and cadSubMgtPktFilterLastChanged is set to the current
              time."
        DEFVAL { false }
        ::= { cadSubMgtPktFilterExtEntry 1 }

cadSubMgtPktFilterLastChanged OBJECT-TYPE
        SYNTAX       TimeStamp
        MAX-ACCESS   read-only
        STATUS       current
        DESCRIPTION
             "The time at which docsSubMgtPktFilterMatches might have
              experienced a discontinuity, such as when
              cadSubMgtPktFilterMatchesReset is set to true(1) or when any
              of the parameters in the docsSubMgtPktFilterTable affecting
              filtering last changed."
        ::= { cadSubMgtPktFilterExtEntry 2 }

cadSubMgtPktFilterCaptureEnabled OBJECT-TYPE
        SYNTAX       TruthValue
        MAX-ACCESS   read-write
        STATUS       current
        DESCRIPTION
             "Indicates whether packets matching this filter are captured
              for possible debug logging.  A value of true indicates that
              packets matching this filter will be captured.  A value of
              false indicates that packets matching this filter will not
              be captured for later debuggging."
        DEFVAL { false }
        ::= { cadSubMgtPktFilterExtEntry 3 }



--
-- Cadant LAES count table
--
cadLaesCountTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF CadLaesCountEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "This table references pktcEScTapStreamTable"
        ::= { cadHardwareMeasMib 26 }

cadLaesCountEntry OBJECT-TYPE
        SYNTAX      CadLaesCountEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "For every cadLaesCountEntry, there is a matching
                       pktcEScTapStreamEntry."
        INDEX { pktcEScTapMediationContentId, pktcEScTapStreamIndex }
        ::= { cadLaesCountTable 1 }

CadLaesCountEntry ::= SEQUENCE {
            cadLaesCountMacDomainIfIndex     InterfaceIndex,
            cadLaesCountStreamDirection      IfDirection,
            cadLaesCountInterceptedPackets   Counter32,
            cadLaesCountInterceptDrops       Counter32
        }

cadLaesCountMacDomainIfIndex OBJECT-TYPE
        SYNTAX       InterfaceIndex
        MAX-ACCESS   read-only
        STATUS       current
        DESCRIPTION
             "This object indicates the cable Mac domain interface index that the
              LAES stream is associated with."

        ::= { cadLaesCountEntry 1 }

cadLaesCountStreamDirection OBJECT-TYPE
        SYNTAX       IfDirection
        MAX-ACCESS   read-only
        STATUS       current
        DESCRIPTION
             "This object indicates either downstream or upstream direction that the
              LAES stream is associated with."
        ::= { cadLaesCountEntry 2 }

cadLaesCountInterceptedPackets OBJECT-TYPE
        SYNTAX       Counter32
        MAX-ACCESS   read-only
        STATUS       current
        DESCRIPTION
             "Indicates number of intercepted packets are sent of the LAES stream."  
        ::= { cadLaesCountEntry 3 }

cadLaesCountInterceptDrops OBJECT-TYPE
        SYNTAX       Counter32
        MAX-ACCESS   read-only
        STATUS       current
        DESCRIPTION
             "Indicates number of intercepted packets are dropped of the LAES stream."  
        ::= { cadLaesCountEntry 4 }

--
-- FFT Status Table
--
cadFftUpstreamChannelTable  OBJECT-TYPE
        SYNTAX      SEQUENCE OF CadFftUpstreamChannelEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Reports current FFT operation status."
        ::= { cadHardwareMeasMib 24 }

cadFftUpstreamChannelEntry OBJECT-TYPE
        SYNTAX      CadFftUpstreamChannelEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "FFT status for a single upstream channel with ifType
             docsCableUpstreamInterface(129)."
        INDEX { ifIndex }
        ::= { cadFftUpstreamChannelTable 1 }

CadFftUpstreamChannelEntry ::= SEQUENCE {
            cadFftInProgress  TruthValue,
            cadFftCurrentTriggers Unsigned32
        }

cadFftInProgress OBJECT-TYPE
        SYNTAX       TruthValue
        MAX-ACCESS   read-only
        STATUS       current
        DESCRIPTION
             "The current state on the FFT capture. "
        ::= { cadFftUpstreamChannelEntry 1 }

cadFftCurrentTriggers OBJECT-TYPE
        SYNTAX       Unsigned32
        MAX-ACCESS   read-only
        STATUS       current
        DESCRIPTION
             "The number of times the FFT capture has triggered and
              transferred data from the Broadcom device."
        ::= { cadFftUpstreamChannelEntry 2 }

END