-- Cadant CMTS PacketCable Event Message MIB
--

CADANT-CMTS-PC-EVENTMSG-MIB DEFINITIONS ::= BEGIN


IMPORTS
	MODULE-IDENTITY,
	OBJECT-TYPE,
	Integer32,
	IpAddress,
	Unsigned32
		FROM SNMPv2-SMI

        TEXTUAL-CONVENTION,
	RowStatus,
	TruthValue
		FROM SNMPv2-TC

	cadPCMibObjects
		FROM CADANT-CMTS-PACKETCABLE-MIB;

cadEvMsgMIB   MODULE-IDENTITY
        LAST-UPDATED    "200710240000Z" -- October 24, 2007
        ORGANIZATION    "Arris Interactive"
        CONTACT-INFO    "Kathy Ashe"
        DESCRIPTION     "PacketCable event message MIB. This MIB
                         contains objects for PacketCable Event Messaging
                         between the Cadant C4 CMTS and a record keeping server
                         or distribution function."

        REVISION        "200710240000Z" -- October 24, 2007
        DESCRIPTION     "Move from cadExperimental to cadPCMIB in the hierarchy"

        REVISION        "200505230000Z" -- May 23, 2005
        DESCRIPTION     "Change the default value of cadEvMsgMaxBatchSize, cadEvMsgEnableFlag,
                         and cadEvMsgMaxRetry"

        REVISION        "200302050000Z" -- February 5, 2003
        DESCRIPTION     "added cadEvMsgEnableFlag object"

        REVISION        "200212270000Z" --December 27, 2002
        DESCRIPTION     "added cadEvMsgMaxBatchSize object"


	::= { cadPCMibObjects 5 }


TimeOfDay ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "1d:1d"
    STATUS       current
    DESCRIPTION
            "A time-of-day specification in hours:minutes.

            field  octets  contents                  range
            -----  ------  --------                  -----
              1       1    hour                      0..23
              2       1    minutes                   0..59"
    SYNTAX    OCTET STRING (SIZE (0..5))

    
cadEvMsgMibBase OBJECT IDENTIFIER ::= { cadEvMsgMIB 1 }


cadEvMsgElementType OBJECT-TYPE
    SYNTAX          Unsigned32(0..2)
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION     "Element type to be included in Event Message header.
                     Default value 2 = CMTS."
    REFERENCE       "'Cadant CMTS Requirements for PacketCable' requirement 4.2.0.0.1"
    DEFVAL          {2}
    ::= { cadEvMsgMibBase 1 }

cadEvMsgElementId OBJECT-TYPE
    SYNTAX          Unsigned32(0..100000)
    MAX-ACCESS      read-write
    STATUS	    current
    DESCRIPTION     "Five digit Element ID to be included in Event Message header.
                     Must be unique network-wide."
    REFERENCE       "'Cadant CMTS Requirements for PacketCable' requirement 4.2.0.0.2"
    DEFVAL          {100000}
    ::= { cadEvMsgMibBase 2 }

cadEvMsgMaxAge OBJECT-TYPE
    SYNTAX          Unsigned32(0..30)
    UNITS           "minutes"
    MAX-ACCESS      read-write
    STATUS	    current
    DESCRIPTION     "Maximum amount of time, in minutes, that an event message 
                     destined for the RKS may reside in the CMTS, for UDP-based
                     batch mode."
    DEFVAL          {1}
    ::= { cadEvMsgMibBase 3 }

cadEvMsgRetransTimer OBJECT-TYPE
    SYNTAX          Unsigned32(10..10000)
    UNITS           "milliseconds"
    MAX-ACCESS      read-write
    STATUS	    current
    DESCRIPTION     "Maximum amount of time, in milliseconds, that the CMTS will wait 
                     for the RKS to acknowledge an event message before
		     attempting to retransmit the message."
    DEFVAL          {1000}
    ::= { cadEvMsgMibBase 4 }


cadEvMsgMaxRetry    OBJECT-TYPE
    SYNTAX          Unsigned32(0..9)
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "Maximum number of retry attempts for transmitting an event
                     message. If this value is set to 0, then we only try 
                     once."
    DEFVAL          {0}
    ::= { cadEvMsgMibBase 5 }

cadEvMsgMaxBatchSize    OBJECT-TYPE
    SYNTAX          Unsigned32(2..10)
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "Maximum number of radius event messages that can be batched.
                   This value must be set  to greater than  1 to allow batching" 
    DEFVAL          {10}
    ::= { cadEvMsgMibBase 6 }

cadEvMsgEnableFlag    OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "Boolean for enabling/disabling Event Messaging"
                    
    DEFVAL          {false}
    ::= { cadEvMsgMibBase 7 }
--=============================================================================
--
--  cadEvMsgTransTimeTable
--
--  The cadEvMsgTransTimeTable stores up to 24 time-of-day values
--  when the CMTS will transmit any event messages stored locally.
--
--  All of the objects in this table are read-write.
--
--=============================================================================

cadEvMsgTransTimeTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF CadEvMsgTransTimeEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "Table of up to 24 time-of-day values for Event Messaging."
    REFERENCE       "'Cadant CMTS Requirements for PacketCable' requirement 4.2.0.0.5"
    ::= { cadEvMsgMIB 2 }

cadEvMsgTransTimeEntry OBJECT-TYPE
    SYNTAX          CadEvMsgTransTimeEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION     "This entry contains one row in the table."
    INDEX { cadEvMsgTransTimeIdx }
    ::= { cadEvMsgTransTimeTable 1 }

CadEvMsgTransTimeEntry ::= SEQUENCE {
    cadEvMsgTransTimeIdx        Unsigned32,
    cadEvMsgTransTOD		TimeOfDay,
    cadEvMsgTransTimeStatus	RowStatus
    }

cadEvMsgTransTimeIdx OBJECT-TYPE
    SYNTAX          Unsigned32(1..24)
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION     "An index into the cadEvMsgTransTimeTable. There can
                     be up to 24 entries. "
    ::= { cadEvMsgTransTimeEntry 1 }


cadEvMsgTransTOD OBJECT-TYPE
    SYNTAX          TimeOfDay
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION     "Time of day to transmit Event Messages, in HH:MM format"
    DEFVAL          {"00:00"}
    ::= { cadEvMsgTransTimeEntry 2 }

cadEvMsgTransTimeStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "Row status entry for the table."
    ::= { cadEvMsgTransTimeEntry 3 }

END