-- Cadant CMTS PacketCable MIB
--

CADANT-CMTS-PACKETCABLE-MIB DEFINITIONS ::= BEGIN


IMPORTS
    MODULE-IDENTITY,
    OBJECT-TYPE,
    Integer32,
    IpAddress,
    Unsigned32,
    Counter32
        FROM SNMPv2-SMI

    TEXTUAL-CONVENTION,
    RowStatus,
    TruthValue,
    DisplayString,
    TimeStamp
        FROM SNMPv2-TC

    ifIndex,
    InterfaceIndex
        FROM IF-MIB
    IfDirection
        FROM DOCS-QOS3-MIB

    cadCable
        FROM CADANT-PRODUCTS-MIB

    CardId,
    AdminState
        FROM CADANT-TC

    cadOvSysCpuStatus
        FROM CADANT-CMTS-PROCESS-MIB

    cadIfCmtsCardNumber
        FROM CADANT-CMTS-DOWNCHANNEL-MIB;

cadPCMIB   MODULE-IDENTITY
        

    LAST-UPDATED    "201512210000Z" -- December 21, 2015
    ORGANIZATION    "Arris Internaional"
    CONTACT-INFO    "Kathy Ashe"
    DESCRIPTION     "PacketCable general-purpose management MIB. This MIB
                     contains objects which are specific to PacketCable but
                     not covered in any of the more-specialized MIBS."

    REVISION        "201512210000Z" -- December 21, 2015
    DESCRIPTION     "Add cadPCPEPIDHostname"

    REVISION        "201108040000Z" -- Aug 4, 2011
    DESCRIPTION     "Replace cerCardId with cadPCCardId in cadPCCAMEntry.
                     Replace cerCardId with cadPCConnRateOverloadRejCardId in cadPCConnRateOverloadRejEntry."

    REVISION        "201107260000Z" -- July 26, 2011
    DESCRIPTION     "Replace cardId with cerCardId"

    REVISION        "200902260000Z" -- February 26, 2009
    DESCRIPTION     "For DQOS1.5-N-06.0339-4, added cadPCSendSubId."

    REVISION        "200711120000Z" -- November 12, 2007
    DESCRIPTION     "Removed cadPCAuthModuleEnabled. No longer needed in R7.0.
                     For I-CMTS, added cadPCCAMCblMacTable for populating 12U cards"

    REVISION        "200710240000Z" -- October 24, 2007
    DESCRIPTION     "Move from cadExperimental tree to cadCable in the hierarchy"

    REVISION        "200709060000Z" -- September 6, 2007
    DESCRIPTION     "Replace DOCS-QOS-MIB with DOCS-QOS3-MIB"

    REVISION        "200508100000Z" -- August 10, 2005
    DESCRIPTION     "Add admission control for PacketCable MultiMedia."

    REVISION        "200505160000Z" -- May 16, 2005
    DESCRIPTION     "For bug 68227, added gateReportState to CadPCGateCtlCountEntry opcodes. Steve Nolle"

    REVISION        "200411100000Z" -- November 10, 2004
    DESCRIPTION     "Add MIB entries for improved deployment troubleshooting (phase 1)"

    REVISION        "200410040000Z" -- October 4, 2004
    DESCRIPTION     "Obsoleting cadPCMaxOverloadCalls, cadPCMaxYellowOverloadCalls,
                     and cadPCMaxRedOverloadCalls and replacing them with
                     cadPCMaxOverloadGateMsgs, cadPCMaxYellowOverloadGateMsgs, and
                     cadPCMaxRedOverloadGateMsgs."

    REVISION        "200402190000Z" -- February 19, 2004
    DESCRIPTION     "Change defaults to match those in down/up channel mibs."

    REVISION        "200402180000Z" -- February 18, 2004
    DESCRIPTION     "Change preemption default to true."

    REVISION        "200402150000Z" -- February 15, 2004
    DESCRIPTION     "Rename some variables to support setting channel
                     default values from the global settings."

    REVISION        "200309040000Z" -- September 4, 2003
    DESCRIPTION     "Add cadPCMaxRedOverloadDSaCalls, cadPCMaxYellowOverloadDSaCalls,
                    and cadPCMaxOverloadDSaCalls -- by Brian Barker"
         
    REVISION        "200307280000Z" -- July 25, 2003
    DESCRIPTION     "Add cadPCMaxRedOverloadCalls, cadPCMaxYellowOverloadCalls,
                    and cadPCMaxOverloadCalls -- by Steve Nolle"

    REVISION        "200305200000Z" --  May 20, 2003
    DESCRIPTION     "Add cadPCAdminState, obsoleted cadPCMixedDQoSFlag"

    REVISION        "200208260000Z" -- August 26, 2002
    DESCRIPTION     "Put cadPCAuthModuleEnabled into a table to make it per-CAM"

    REVISION        "200107240000Z" -- July 24, 2001
    DESCRIPTION     "Original Version"

        ::= { cadCable 115 }


CadPCAnomalyCode ::= TEXTUAL-CONVENTION
    STATUS          current
    DESCRIPTION     "Corresponds to the PacketCable Reason and PacketCable 
                     Error codes documented in PKT-SP-DQOS-I06-030415.
         
                     To get index for PacketCable Error, mask off the low-order 
                     16-bit Error Sub-code.
                    
                     The PacketCable Reasons match the combination Reason-Code 
                     and Reason Sub-code.
         
                     Normal operation is not pegged and therefor is not 
                     included below."
    SYNTAX INTEGER {
        deletedLocalGateCoordinationFailure     (1),        -- 0x00000001
        deletedRemoteGateCoordinationFailure    (2),        -- 0x00000002
        deletedRevokedAuthorization             (3),        -- 0x00000003
        deletedUnexpectedGateOpen               (4),        -- 0x00000004
        deletedLocalGateCloseFailure            (5),        -- 0x00000005
        deletedUnknownReason                    (127),      -- 0x0000007f
        failedNoGatesAvailable                  (65535),    -- 0x00010000
        closedPreemptionOfResources             (65537),    -- 0x00010001
        closedLackOfReservationMaintenance      (65538),    -- 0x00010002
        closedMTADeregistration                 (65539),    -- 0x00010003
        closedTimerT0Expiry                     (65540),    -- 0x00010004
        closedTimerT1Rxpiry                     (65541),    -- 0x00010005
        closedTimerT7Rxpiry                     (65542),    -- 0x00010006
        closedTimerT8Rxpiry                     (65543),    -- 0x00010007
        closedUnknownReason                     (65663),    -- 0x0001007f
        failedUnknownGateId                     (131072),   -- 0x00020000
        failedIllegalSessionClassValue          (196608),   -- 0x00030000
        failedMTAExceededGateLimit              (262144),   -- 0x00040000
        failedGateAlreadySet                    (327680),   -- 0x00050000
        failedMissingRequiredObject             (393216),   -- 0x00060000
        failedInvalidObject                     (458752),   -- 0x00070000
        failedUnknownReason                     (8323072)   -- 0x007f0000
    }

CadPCAdmCtlPriority ::= TEXTUAL-CONVENTION
    STATUS          current
    DESCRIPTION     "Symbolic description of CAC priority levels for PacketCable
                     sessions.  Note that the MIB values are one greater than
                     the Session Class priority values defined in the
                     PacketCable MultiMedia Specification."
    SYNTAX INTEGER {
        eightPriority     (1),
        seventhPriority   (2),
        sixthPriority     (3),
        fifthPriority     (4),
        fourthPriority    (5),
        thirdPriority     (6),
        secondPriority    (7),
        firstPriority     (8)
    }

cadPCMibObjects OBJECT IDENTIFIER ::= { cadPCMIB 1 }
cadPCMibBase OBJECT IDENTIFIER ::= { cadPCMibObjects 1 }

--==============================================================================
--
-- Resource Usage Limits
--
-- There are two admission policies that must be implemented. One is for general 
-- telephony use, the otheris for higher priority (E911) use. The upstream and 
-- downstream portions of a particular policy are managed independently. The 
-- policies may overlap or they may be disjoint.
--
--  The bandwidth map would look like
--
--  0.......................................................................100
--  |======NormMin=====|
--  |================NormMax===========|
--                     |==EmergMin==|
--                     |========EmergMax=======|
--
--
--  If all minimums are zero, the bandwidth map would look like:
--
--  0.......................................................................100
--  |================NormMax===========|
--  |===============EmergMax=============|
--
--  Notice that there are cases when invalid combinations may result. Therefore,
--  the following rules MUST be enforced
--
--  NormMin MUST be less than or equal to NormMax
--
--  EmergMin MUST be less than or equal to EmergMax
--
--  NormMin + EmergMin MUST be less than or equal to Total Allowed
--
--      
--
--==============================================================================

cadPCPreemptionAllowed OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "Indicates whether the system will preempt another 
                     session for an emergency call."
    DEFVAL          { true }
    ::= { cadPCMibBase 3 }
    
cadPCUpNormAllowedUsage OBJECT-TYPE
    SYNTAX          INTEGER (0..100)
    UNITS           "percent"       
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "Maximum percentage of upstream resources that may be used by
                     non-emergency telephony services. This is also the maximum 
                     amount of resources non-exclusively allocated to sessions of 
                     this type"
    REFERENCE       "Cadant CMTS Requirements for PacketCable requirement 3.3.3.0.2"
    DEFVAL          { 50 }
    ::= { cadPCMibBase 4 }

cadPCUpNormResUsage OBJECT-TYPE
    SYNTAX          INTEGER (0..100)
    UNITS           "percent"       
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "Minimum percentage of upstream resources that may be used by
                     non-emergency telephony services. This is also the maximum amount 
                     of resources exclusively allocated to sessions of this type. If
                     the value of this object is non-zero, then a portion of the upstream
                     bandwidth will be set aside for normal telephony use only - reducing
                     the bandwidth that is available for normal data."
    REFERENCE       "'Cadant CMTS Requirements for PacketCable' requirement 3.3.3.0.2"
    DEFVAL          { 0 }
    ::= { cadPCMibBase 5 }

cadPCUpEmerAllowedUsage OBJECT-TYPE
    SYNTAX          INTEGER (0..100)
    UNITS           "percent"       
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "Maximum percentage of upstream resources that may be used by
                     emergency telephony services."
    REFERENCE       "Cadant CMTS Requirements for PacketCable requirement 3.3.3.0.2"
    DEFVAL          { 70 }
    ::= { cadPCMibBase 6 }

cadPCUpEmerResUsage OBJECT-TYPE
    SYNTAX          INTEGER (0..100)
    UNITS           "percent"       
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "Minimum percentage of upstream resources that may be used by
                     emergency telephony services. If the value of this object is 
                     non-zero, then a portion of the upstream bandwidth will be set 
                     aside for emercency telephony use only - reducing the bandwidth 
                     that is available for normal data."
    REFERENCE       "'Cadant CMTS Requirements for PacketCable' requirement 3.3.3.0.2"
    DEFVAL          { 0 }
    ::= { cadPCMibBase 7 }

cadPCDownNormAllowedUsage OBJECT-TYPE
    SYNTAX          INTEGER (0..100)
    UNITS           "percent"       
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "Maximum percentage of downstream resources that may be used by
                     non-emergency telephony services. This is also the maximum 
                     amount of resources non-exclusively allocated to sessions of 
                     this type"
    REFERENCE       "'Cadant CMTS Requirements for PacketCable' requirement 3.3.3.0.2"
    DEFVAL          { 50 }
    ::= { cadPCMibBase 8 }

cadPCDownNormResUsage OBJECT-TYPE
    SYNTAX          INTEGER (0..100)
    UNITS           "percent"       
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "Minimum percentage of downstream resources that may be used by
                     non-emergency telephony services. This is also the maximum amount 
                     of resources exclusively allocated to sessions of this type. If
                     the value of this object is non-zero, then a portion of the upstream
                     bandwidth will be set aside for normal telephony use only - reducing
                     the bandwidth that is available for normal data."
    REFERENCE       "'Cadant CMTS Requirements for PacketCable' requirement 3.3.3.0.2"
    DEFVAL          { 0 }
    ::= { cadPCMibBase 9 }

cadPCDownEmerAllowedUsage OBJECT-TYPE
    SYNTAX          INTEGER (0..100)
    UNITS           "percent"       
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "Maximum percentage of downstream resources that may be used by
                     emergency telephony services."
    REFERENCE       "'Cadant CMTS Requirements for PacketCable' requirement 3.3.3.0.2"
    DEFVAL          { 70 }
    ::= { cadPCMibBase 10 }

cadPCDownEmerResUsage OBJECT-TYPE
    SYNTAX          INTEGER (0..100)
    UNITS           "percent"       
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "Minimum percentage of downstream resources that may be used by
                     emergency telephony services. If the value of this object is non-zero, 
                     then a portion of the upstream bandwidth will be set aside for normal 
                     telephony use only - reducing the bandwidth that is available for 
                     normal data."
    REFERENCE       "'Cadant CMTS Requirements for PacketCable' requirement 3.3.3.0.2"
    DEFVAL          { 0 }
    ::= { cadPCMibBase 11 }


--=============================================================================
--  cadPCCAMTable
--
--  The cadPCCAMTable provides the ability to manage PacketCable parameters on
--  a per-CAM basis for 2D12U only.
--
--  All objects are read-write
--
--=============================================================================
cadPCCAMTable   OBJECT-TYPE
    SYNTAX      SEQUENCE OF CadPCCAMEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "Table of Per-CAM PacketCable Data for 2D12U only"
    ::= { cadPCMibBase 12 }

cadPCCAMEntry   OBJECT-TYPE
    SYNTAX      CadPCCAMEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "This entry contains all of the PacketCable data that
                is to be managed on a per-CAM basis."
    INDEX { cadPCCardId }    --  cardIds are 1-based!
    ::= { cadPCCAMTable 1 }

CadPCCAMEntry ::= SEQUENCE {
    cadFreeDSxAllowed               TruthValue,
    cadPCMaxOverloadDSaCalls        Unsigned32,
    cadPCMaxYellowOverloadDSaCalls  Unsigned32,
    cadPCMaxRedOverloadDSaCalls     Unsigned32,
    cadPCCardId                         CardId
    }

cadFreeDSxAllowed OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "Indicates whether the authorization module will allow a
                    DOCSIS MAC Messaging Dynamic Services request (DSx) without
                    a gate-ID in an authorization block."
    DEFVAL          { true }
    ::= { cadPCCAMEntry 1 }

cadPCMaxOverloadDSaCalls  OBJECT-TYPE
    SYNTAX          Unsigned32(1..10000)
    UNITS           "connections per 10 seconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "the max number of connections we will allow per 10 second interval
                           when the system cpu is in a normal condition, i.e. no overload."
    DEFVAL          { 10000 }
    ::= { cadPCCAMEntry 2 }

cadPCMaxYellowOverloadDSaCalls  OBJECT-TYPE
    SYNTAX          Unsigned32(1..10000)
    UNITS           "connections per 10 seconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "the max number of connections we will allow per 10 second interval
                           when the system cpu is in a yellow overload condition."
    DEFVAL          { 10000 }
    ::= { cadPCCAMEntry 3 }

cadPCMaxRedOverloadDSaCalls  OBJECT-TYPE
    SYNTAX          Unsigned32(1..10000)
    UNITS           "connections per 10 seconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "the max number of connections we will allow per 10 second interval
                           when the system cpu is in a red overload condition."
    DEFVAL          { 3000 }
    ::= { cadPCCAMEntry 4 }

cadPCCardId OBJECT-TYPE
        SYNTAX      CardId
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "The unique id of this card within the shelf."
    ::= { cadPCCAMEntry 5 }

cadPCAdminState OBJECT-TYPE
    SYNTAX          AdminState
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "The administrative state of PacketCable services on the CMTS."
    DEFVAL          { down }
    ::= { cadPCMibBase 13 }

cadPCMaxOverloadCalls  OBJECT-TYPE
    SYNTAX          Unsigned32(1..10000)
    UNITS           "connections per 10 seconds"
    MAX-ACCESS      read-write
    STATUS          obsolete
    DESCRIPTION     "the max number of connections we will allow per 10 second interval
                           when the system cpu is in a normal condition, i.e. no overload."
    DEFVAL          { 450 }
    ::= { cadPCMibBase 14 }

cadPCMaxYellowOverloadCalls  OBJECT-TYPE
    SYNTAX          Unsigned32(1..10000)
    UNITS           "connections per 10 seconds"
    MAX-ACCESS      read-write
    STATUS          obsolete
    DESCRIPTION     "the max number of connections we will allow per 10 second interval
                           when the system cpu is in a yellow overload condition."
    DEFVAL          { 450 }
    ::= { cadPCMibBase 15 }

cadPCMaxRedOverloadCalls  OBJECT-TYPE
    SYNTAX          Unsigned32(1..10000)
    UNITS           "connections per 10 seconds"
    MAX-ACCESS      read-write
    STATUS          obsolete
    DESCRIPTION     "the max number of connections we will allow per 10 second interval
                           when the system cpu is in a red overload condition."
    DEFVAL          { 41 }
    ::= { cadPCMibBase 16 }

cadPCDownTotalAllowedUsage OBJECT-TYPE
    SYNTAX          INTEGER (0..100)
    UNITS           "percent"       
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "Maximum percentage of downstream resources that may be
                     used by both normal and emergency telephony services."
    REFERENCE       "'Cadant CMTS Requirements for PacketCable' requirement 3.3.3.0.2"
    DEFVAL          { 70 }
    ::= { cadPCMibBase 17 }

cadPCUpTotalAllowedUsage OBJECT-TYPE
    SYNTAX          INTEGER (0..100)
    UNITS           "percent"       
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "Maximum percentage of upstream resources that may be
                     used by both normal and emergency telephony services."
    REFERENCE       "'Cadant CMTS Requirements for PacketCable' requirement 3.3.3.0.2"
    DEFVAL          { 70 }
    ::= { cadPCMibBase 18 }

cadPCMaxOverloadGateMsgs  OBJECT-TYPE
    SYNTAX          Unsigned32(1..10000)
    UNITS           "gate messages per 10 seconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "the max number of gate messages that the system will process per 10 
                     second interval when the system cpu is in a normal condition, i.e. 
                     no overload."
    DEFVAL          { 900 }
    ::= { cadPCMibBase 19 }

cadPCMaxYellowOverloadGateMsgs  OBJECT-TYPE
    SYNTAX          Unsigned32(1..10000)
    UNITS           "gate messages per 10 seconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "the max number of gate messages that the system will process per 10 
                     second interval when the system cpu is in a yellow overload condition."
    DEFVAL          { 900 }
    ::= { cadPCMibBase 20 }

cadPCMaxRedOverloadGateMsgs  OBJECT-TYPE
    SYNTAX          Unsigned32(1..10000)
    UNITS           "gate messages per 10 seconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "the max number of gate messages that the system will process per 10 
                     second interval when the system cpu is in a red overload condition."
    DEFVAL          { 300 }
    ::= { cadPCMibBase 21 }

cadPCClearGateCounts  OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "set to true to clear the gate counts, always false when read"
    DEFVAL          { false }
    ::= { cadPCMibBase 25 }

cadPCClearAnomalyCounts  OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "set to true to clear the anomaly counts, always false when read"
    DEFVAL          { false }
    ::= { cadPCMibBase 26 }

cadPCClearConnRateOverloadCounts  OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "set to true to clear the connection rate overload counts, always false when read"
    DEFVAL          { false }
    ::= { cadPCMibBase 27 }

cadPCClearEvMsgCounts  OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "set to true to clear the event messaging counts, always false when read"
    DEFVAL          { false }
    ::= { cadPCMibBase 28 }

cadPCClearCopsCounts  OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "set to true to clear the COPS counts, always false when read"
    DEFVAL          { false }
    ::= { cadPCMibBase 29 }

cadPCClearGateCtlCounts  OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "set to true to clear the gate control counts, always false when read"
    DEFVAL          { false }
    ::= { cadPCMibBase 30 }


--=============================================================================
--
--  cadPCMibGateCounts
--
--=============================================================================
cadPCMibGateCounts OBJECT IDENTIFIER ::= { cadPCMibBase 40 }

cadPCTotalGateCount  OBJECT-TYPE
    SYNTAX          Counter32
    UNITS           "gates"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION     "Total number of gates that have been created since the last reboot 
                     of the system or since the last time that this counter was manually 
                     reset."
    REFERENCE       "'C4 Product Specification Agreement: PacketCable Deployment Tools 
                     on the C4 CMTS' requirement 2.3.1.2-30"
    ::= { cadPCMibGateCounts 1 }

cadPCGateAllocatedStateCount OBJECT-TYPE
    SYNTAX          Counter32
    UNITS           "gates"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION     "Total number of gates that are currently in the ALLOCATED state"
    REFERENCE       "'C4 Product Specification Agreement: PacketCable Deployment Tools 
                     on the C4 CMTS' requirement 2.3.1.2-40"
    ::= { cadPCMibGateCounts 2 }

cadPCGateAuthorizedStateCount OBJECT-TYPE
    SYNTAX          Counter32
    UNITS           "gates"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION     "Total number of gates that are currently in the AUTHORIZED state"
    REFERENCE       "'C4 Product Specification Agreement: PacketCable Deployment Tools 
                     on the C4 CMTS' requirement 2.3.1.2-40"
    ::= { cadPCMibGateCounts 3 }

cadPCGateReservedStateCount OBJECT-TYPE
    SYNTAX          Counter32
    UNITS           "gates"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION     "Total number of gates that are currently in the RESERVED state"
    REFERENCE       "'C4 Product Specification Agreement: PacketCable Deployment Tools 
                     on the C4 CMTS' requirement 2.3.1.2-40"
    ::= { cadPCMibGateCounts 4 }

cadPCGateCommittedStateCount OBJECT-TYPE
    SYNTAX          Counter32
    UNITS           "gates"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION     "Total number of gates that are currently in the COMMITTED state"
    REFERENCE       "'C4 Product Specification Agreement: PacketCable Deployment Tools 
                     on the C4 CMTS' requirement 2.3.1.2-40"
    ::= { cadPCMibGateCounts 5 }

cadPCGateLastCleared OBJECT-TYPE
    SYNTAX          TimeStamp
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION     "The value of sysUptime when the gate counts were last cleared."
    DEFVAL          { 0 }
    ::= { cadPCMibGateCounts 6 }

--=============================================================================
--  cadPCAnomalyCountTable
--
--  The cadPCAnomalyCountTable lists counts for anomalies found during calls.
--  These anomaly counts increase continuously from boot or from last counter
--  reset.
--
--  All objects are read-write
--
--=============================================================================
cadPCAnomalyCountTable   OBJECT-TYPE
    SYNTAX          SEQUENCE OF CadPCAnomalyCountEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION     "Table of anomaly counts"
    REFERENCE       "'C4 Product Specification Agreement: PacketCable Deployment Tools 
                     on the C4 CMTS' requirement 2.3.1.2-50"
    ::= { cadPCMibBase 45 }

cadPCAnomalyCountEntry   OBJECT-TYPE
    SYNTAX          CadPCAnomalyCountEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION     "Entry of anomaly counts"
    INDEX           { cadPCAnomalyCode }
    ::= { cadPCAnomalyCountTable 1 }

CadPCAnomalyCountEntry ::= SEQUENCE {
    cadPCAnomalyCode  CadPCAnomalyCode,
    cadPCAnomalyCount Counter32
    }

cadPCAnomalyCode  OBJECT-TYPE
    SYNTAX          CadPCAnomalyCode
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION     "PacketCable anomaly code"
    REFERENCE       "'C4 Product Specification Agreement: PacketCable Deployment Tools 
                     on the C4 CMTS' requirement 2.3.1.2-50"
    ::= { cadPCAnomalyCountEntry 1 }

cadPCAnomalyCount OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION     "Count of anomalies of the corresponding type that have occurred
                     since boot or since the last manual reset of this count."
    REFERENCE       "'C4 Product Specification Agreement: PacketCable Deployment Tools 
                     on the C4 CMTS' requirement 2.3.1.2-50"
    ::= { cadPCAnomalyCountEntry 2 }

cadPCAnomalyLastCleared OBJECT-TYPE
    SYNTAX          TimeStamp
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION     "The value of sysUptime when the anomaly counts were last cleared."
    DEFVAL          { 0 }
    ::= { cadPCMibBase 46 }

cadPCSendSubId OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "Indicates whether the C4 will send a subscriber ID in every DQoS gate-open
                     and gate-close message. This is provisioned per-CMTS. ECN DQOS1.5-N-06.0339-4"
    DEFVAL          { false }
    ::= { cadPCMibBase 47 }


--=============================================================================
--  cadPCConnReqRateHistoryTable
--
--  The cadPCConnRateHistoryTable contains a historical view of the number of
--  new PC connections (gates) that have been requested (but not necessarily 
--  granted) per second.
--
--  This table may be maintained in a "lazy" manner whereby the maintaining 
--  algorithm only gets invoked when the counts are read or pegged.
--  
--  One entry should exist for each of the last 60 seconds. As time progresses,
--  older entried get deleted. If the algorithm that maintains this history 
--  does not get invoked for greater than 1 second, the algorithm should indicate 
--  a value of "-1" for each of the seconds that passed without an invocation.
--
--=============================================================================
cadPCConnRateReqHistoryTable   OBJECT-TYPE
    SYNTAX          SEQUENCE OF CadPCConnRateReqHistoryEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION     "Table of connection request rate history"
    REFERENCE       "'C4 Product Specification Agreement: PacketCable Deployment Tools 
                     on the C4 CMTS' requirement 2.3.1.2-60, 2.3.1.2-65"
    ::= { cadPCMibBase 50 }

cadPCConnRateReqHistoryEntry   OBJECT-TYPE
    SYNTAX          CadPCConnRateReqHistoryEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION     "Entry of connection request rate"
    INDEX           { cadPCConnRateReqHistoryTimeStamp }
    ::= { cadPCConnRateReqHistoryTable 1 }

CadPCConnRateReqHistoryEntry ::= SEQUENCE {
    cadPCConnRateReqHistoryTimeStamp TimeStamp,
    cadPCConnRateReqHistoryCount Counter32
    }

cadPCConnRateReqHistoryTimeStamp  OBJECT-TYPE
    SYNTAX          TimeStamp
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION     "Value of sysUpTime (rounded down to the nearest second) when 
                     this entry was created"
    REFERENCE       "'C4 Product Specification Agreement: PacketCable Deployment Tools 
                     on the C4 CMTS' requirement 2.3.1.2-60, 2.3.1.2-65"
    ::= { cadPCConnRateReqHistoryEntry 1 }

cadPCConnRateReqHistoryCount OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION     "Count of connection requests (gates) made during the second"
    REFERENCE       "'C4 Product Specification Agreement: PacketCable Deployment Tools 
                     on the C4 CMTS' requirement 2.3.1.2-60, 2.3.1.2-65"
    ::= { cadPCConnRateReqHistoryEntry 2 }

cadPCConnReqMaxHistRate OBJECT-TYPE
    SYNTAX          Counter32
    UNITS           "gates"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION     "Maximum value of any cadPCConnReqRateCount since system boot or
                     reset of this value."
    REFERENCE       "'C4 Product Specification Agreement: PacketCable Deployment Tools 
                     on the C4 CMTS' requirement 2.3.1.2-60"
    ::= { cadPCMibBase 51 }

--=============================================================================
--  cadPCConnRateOverloadRejTable
--
--  Table of counts for rejected connections due to rate-overload protection
--  for the individual card
--
--  These counts continuously increase unless manually reset by the user.
--
--  The system-level counts shall use a cardId of 99 (the "invalid cardId").
--=============================================================================
cadPCConnRateOverloadRejTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CadPCConnRateOverloadRejEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION     "Table of Per-card rate overload reject connection counts"
    REFERENCE       "'C4 Product Specification Agreement: PacketCable Deployment Tools 
                     on the C4 CMTS' requirement 2.3.1.2-70"
    ::= { cadPCMibBase 55 }

cadPCConnRateOverloadRejEntry   OBJECT-TYPE
    SYNTAX          CadPCConnRateOverloadRejEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION     "This entry contains the connection rate overload rejection counts."
    INDEX           { cadPCConnRateOverloadRejCardId,      --  cardIds are 1-based!
                      cadOvSysCpuStatus }        
    ::= { cadPCConnRateOverloadRejTable 1 }

CadPCConnRateOverloadRejEntry ::= SEQUENCE {
    cadPCConnRateOverloadRejCount Counter32,
    cadPCConnRateOverloadRejCardId   CardId
    }

cadPCConnRateOverloadRejCount OBJECT-TYPE
    SYNTAX          Counter32
    UNITS           "connections"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION     "Number of connections that have been rejected as a result of rate
                     overload protection while the system is in the corresponding
                     system-wide overload state since the last system reboot or since
                     the last time that this counter was reset."
    REFERENCE       "'C4 Product Specification Agreement: PacketCable Deployment Tools 
                     on the C4 CMTS' requirement 2.3.1.2-70"
    ::= { cadPCConnRateOverloadRejEntry 1 }

cadPCConnRateOverloadRejCardId OBJECT-TYPE
    SYNTAX      CardId
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
                    "The unique id of this card within the shelf."
    ::= { cadPCConnRateOverloadRejEntry 2 }

cadPCConnRateOverloadLastCleared OBJECT-TYPE
    SYNTAX          TimeStamp
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION     "The value of sysUptime when the connection rate overload counts were last cleared."
    DEFVAL          { 0 }
    ::= { cadPCMibBase 56 }

--=============================================================================
--  cadPCEvMsgCountTable
--
--  The cadPCEvMsgCountTable lists counts of event messages that have been
--  transmitted to each RKS or DF (for Electronic Surveillance Call Data) server
--
--=============================================================================
cadPCEvMsgCountTable    OBJECT-TYPE
    SYNTAX              SEQUENCE OF CadPCEvMsgCountEntry
    MAX-ACCESS          not-accessible
    STATUS              current
    DESCRIPTION         "Table of counts of event messages that have been
                         transmitted to each RKS or DF (for Electronic Surveillance 
                         Call Data) server"
    ::= { cadPCMibBase 60 }

cadPCEvMsgCountEntry   OBJECT-TYPE
    SYNTAX              CadPCEvMsgCountEntry
    MAX-ACCESS          not-accessible
    STATUS              current
    DESCRIPTION         "This entry contains counts of event messages that have been
                         transmitted"
    INDEX               { cadPCEvMsgCountServer, cadPCEvMsgServerIsDF }
    ::= { cadPCEvMsgCountTable 1 }

CadPCEvMsgCountEntry ::= SEQUENCE {
    cadPCEvMsgCountServer   IpAddress,
    cadPCEvMsgServerIsDF    TruthValue,
    cadPCEvMsgType          INTEGER,
    cadPCEvMsgCount         Counter32
    }

cadPCEvMsgCountServer OBJECT-TYPE
    SYNTAX              IpAddress
    MAX-ACCESS          not-accessible
    STATUS              current
    DESCRIPTION         "IP address of RKS or DF server"
    ::= { cadPCEvMsgCountEntry 1 }

cadPCEvMsgServerIsDF OBJECT-TYPE
    SYNTAX              TruthValue
    MAX-ACCESS          not-accessible
    STATUS              current
    DESCRIPTION         "Indicator of type of server. Set to true(1) if server is a
                         delivery function server."
    REFERENCE           "'C4 Product Specification Agreement: PacketCable Deployment Tools 
                         on the C4 CMTS' requirement 2.3.1.2-100"
    DEFVAL              { false }
    ::= { cadPCEvMsgCountEntry 2 }

cadPCEvMsgType OBJECT-TYPE
    SYNTAX              INTEGER {
                            qos-reserve(7),
                            qos-release(8),
                            time-change(17),
                            qos-commit(19),
                            total-packets(9999)
                        }
    MAX-ACCESS          read-only
    STATUS              current
    DESCRIPTION         "Type of message being counted. These map directly to the event
                         message opcodes in the Event Messaging reference"
    REFERENCE           "'PacketCable Event Messages Specification: PKT-SP-EM-I07-030815';
                         'C4 Product Specification Agreement: PacketCable Deployment Tools 
                         on the C4 CMTS' requirement 2.3.1.2-100"
    ::= { cadPCEvMsgCountEntry 3 }

cadPCEvMsgCount OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION         "Count of rejected connections due to channel bandwidth
                         congestion since boot or since the last manual reset of
                         this count."
    REFERENCE           "'C4 Product Specification Agreement: PacketCable Deployment Tools 
                         on the C4 CMTS' requirement 2.3.1.2-100"
    ::= { cadPCEvMsgCountEntry 4 }

cadPCEvMsgCountLastCleared OBJECT-TYPE
    SYNTAX          TimeStamp
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION     "The value of sysUptime when the event messaging counts were last cleared."
    DEFVAL          { 0 }
    ::= { cadPCMibBase 61 }

--=============================================================================
--  cadPCCopsCountTable
--
--  The cadPCCopsCountTable lists counts of COPS messages
--  that have been received from and sent to individual servers.
--
--=============================================================================
cadPCCopsCountTable    OBJECT-TYPE
    SYNTAX              SEQUENCE OF CadPCCopsCountEntry
    MAX-ACCESS          not-accessible
    STATUS              current
    DESCRIPTION         "Table of counts of event messages that have been
                         sent to or received from each server."
    ::= { cadPCMibBase 65 }

cadPCCopsCountEntry   OBJECT-TYPE
    SYNTAX              CadPCCopsCountEntry
    MAX-ACCESS          not-accessible
    STATUS              current
    DESCRIPTION         "This entry contains counts of COPS messages."
    INDEX               { cadPCCopsServer, 
                          cadPCCopsDirection, 
                          cadPCCopsOpcode }
    ::= { cadPCCopsCountTable 1 }

CadPCCopsCountEntry ::= SEQUENCE {
    cadPCCopsServer     IpAddress,
    cadPCCopsDirection  INTEGER,
    cadPCCopsOpcode     INTEGER,
    cadPCCopsCount      Counter32
    }

cadPCCopsServer OBJECT-TYPE
    SYNTAX              IpAddress
    MAX-ACCESS          not-accessible
    STATUS              current
    DESCRIPTION         "IP address of CMS or PS server"
    ::= { cadPCCopsCountEntry 1 }

cadPCCopsDirection OBJECT-TYPE
    SYNTAX              INTEGER {
                            receive(1),
                            transmit(2)
                        }
    MAX-ACCESS          not-accessible
    STATUS              current
    DESCRIPTION         "direction of message flow from viewpoint of the CMTS"
    ::= { cadPCCopsCountEntry 2 }

cadPCCopsOpcode OBJECT-TYPE
    SYNTAX              INTEGER {
                            tcpCxt(0),      -- indicates a TCP layer connection
                            copsReq(1),
                            copsDec(2),
                            copsRpt(3),
                            copsDrq(4),
                            copsSsq(5),
                            copsOpn(6),
                            copsCat(7),
                            copsCC(8),
                            copsKa(9),
                            copsSsc(10)
                        }
    MAX-ACCESS          not-accessible
    STATUS              current
    DESCRIPTION         "Type of message being counted. These map directly to the COPS
                         opcodes in RFC 2748."
    REFERENCE           "'The COPS (Common Open Policy Service) Protocol: RFC2748';
                         'C4 Product Specification Agreement: PacketCable Deployment Tools 
                         on the C4 CMTS' requirement 2.3.1.2-110"
    ::= { cadPCCopsCountEntry 3 }

cadPCCopsCount OBJECT-TYPE
    SYNTAX              Counter32
    MAX-ACCESS          read-only
    STATUS              current
    DESCRIPTION         "Count of COPS messages"
    REFERENCE           "'C4 Product Specification Agreement: PacketCable Deployment Tools 
                         on the C4 CMTS' requirement 2.3.1.2-110"
    ::= { cadPCCopsCountEntry 4 }

cadPCCopsCountLastCleared OBJECT-TYPE
    SYNTAX          TimeStamp
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION     "The value of sysUptime when the COPS counts were last cleared."
    DEFVAL          { 0 }
    ::= { cadPCMibBase 66 }

--=============================================================================
--  cadPCGateCtlCountTable
--
--  The cadPCGateCtlCountTable lists counts of Gate Control messages
--  that have been received from and sent to individual servers.
--
--=============================================================================
cadPCGateCtlCountTable  OBJECT-TYPE
    SYNTAX              SEQUENCE OF CadPCGateCtlCountEntry
    MAX-ACCESS          not-accessible
    STATUS              current
    DESCRIPTION         "Table of counts of event messages that have been
                         sent to or received from each server."
    ::= { cadPCMibBase 70 }

cadPCGateCtlCountEntry   OBJECT-TYPE
    SYNTAX              CadPCGateCtlCountEntry
    MAX-ACCESS          not-accessible
    STATUS              current
    DESCRIPTION         "This entry contains counts of gate control messages."
    INDEX               { cadPCCopsServer, cadPCGateCtlOpcode }
    ::= { cadPCGateCtlCountTable 1 }

CadPCGateCtlCountEntry ::= SEQUENCE {
    cadPCGateCtlOpcode        INTEGER,
    cadPCGateCtlCount         Counter32
    }

cadPCGateCtlOpcode      OBJECT-TYPE
    SYNTAX              INTEGER {
                            gateAllocReq(1),
                            gateAllocAck(2),
                            gateAllocErr(3),
                            gateSetReq(4),
                            gateSetAck(5),
                            gateSetErr(6),
                            gateInfoReq(7),
                            gateInfoAck(8),
                            gateInfoErr(9),
                            gateDeleteReq(10),
                            gateDeleteAck(11),
                            gateDeleteErr(12),
                            gateOpen(13),
                            gateClose(14),
				    gateReportState(15)
                        }
    MAX-ACCESS          not-accessible
    STATUS              current
    DESCRIPTION         "Type of message being counted. These map directly to the gate
                         command type opcodes in the DQoS spec."
    REFERENCE           "'PacketCable Dynamic Quality of Service Specification: 
                         PKT-SP-DQOS-I07-0300815';
                         'C4 Product Specification Agreement: PacketCable Deployment Tools 
                         on the C4 CMTS' requirement 2.3.1.2-120"
    ::= { cadPCGateCtlCountEntry 1 }

cadPCGateCtlCount       OBJECT-TYPE
    SYNTAX              Counter32
    MAX-ACCESS          read-only
    STATUS              current
    DESCRIPTION         "Count of messages since boot or since the last manual reset of
                         this count."
    REFERENCE           "'C4 Product Specification Agreement: PacketCable Deployment Tools 
                         on the C4 CMTS' requirement 2.3.1.2-120"
    ::= { cadPCGateCtlCountEntry 2 }

cadPCGateCtlCountLastCleared OBJECT-TYPE
    SYNTAX          TimeStamp
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION     "The value of sysUptime when the gate control counts were last cleared."
    DEFVAL          { 0 }
    ::= { cadPCMibBase 71 }

--=============================================================================
--  cadPCDefAdmCtlTable
--
--  The cadPCDefAdmCtlTable provides the ability to manage the default 
--  PacketCable admission control policy per priority.
--
--  Upon boot, this table must be populated with sixteen rows - one for
--  each possible PacketCable Multimedia priority and direction. Rows may 
--  be neither created nor destroyed.
--
--=============================================================================

cadPCDefAdmCtlTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CadPCDefAdmCtlEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION     "Table of Per-Priority PacketCable admission 
                     control policies"
    ::= { cadPCMibBase 75 }

cadPCDefAdmCtlEntry   OBJECT-TYPE
    SYNTAX          CadPCDefAdmCtlEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION     "This entry contains all of the default PacketCable 
                     admission policy data."
    INDEX { cadPCDefAdmCtlDirection, cadPCDefAdmCtlPriority }
    ::= { cadPCDefAdmCtlTable 1 }

CadPCDefAdmCtlEntry ::= SEQUENCE {
    cadPCDefAdmCtlDirection     IfDirection,
    cadPCDefAdmCtlPriority      CadPCAdmCtlPriority,
    cadPCDefAdmCtlAllowedUsage  INTEGER,
    cadPCDefAdmCtlReservedUsage INTEGER
}

cadPCDefAdmCtlDirection OBJECT-TYPE
    SYNTAX          IfDirection
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION     "Direction for this default policy data."
    ::= { cadPCDefAdmCtlEntry 1 }

cadPCDefAdmCtlPriority OBJECT-TYPE
    SYNTAX          CadPCAdmCtlPriority
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION     "Priority value assigned to this row."
    ::= { cadPCDefAdmCtlEntry 2 }

cadPCDefAdmCtlAllowedUsage OBJECT-TYPE
    SYNTAX          INTEGER (0..90)
    UNITS           "percent"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "Maximum percentage of resources that may be used by
                     requests at the corresponding priority level. This is
                     also the maximum amount of resources non-exclusively
                     allocated to sessions of this type"
    REFERENCE       "'Cadant CMTS Requirements for PacketCable' requirement 
                      3.3.3.0.2"
    DEFVAL          { 50 }
    ::= { cadPCDefAdmCtlEntry 3 }

cadPCDefAdmCtlReservedUsage OBJECT-TYPE
    SYNTAX          INTEGER (0..90)
    UNITS           "percent"       
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "Minimum percentage of resources that may be used by
                     requests at the corresponding priority level. This is
                     also the maximum amount of resources exclusively 
                     allocated to sessions of this type. If the value of this
                     object is non-zero, then a portion of the bandwidth will
                     be set aside for this priority only - reducing the
                     bandwidth that is available for normal data."
    REFERENCE       "'Cadant CMTS Requirements for PacketCable' requirement 
                     3.3.3.0.2"
    DEFVAL           { 0 }
    ::= { cadPCDefAdmCtlEntry 4 }

--=============================================================================
--  cadPC1xAdmCtlMapTable
--
--  The cadPC1xAdmCtlMapTable provides the ability to map the PacketCable 1.x 
--  admission control policy into the PacketCable Multimedia admission control
--  policy.
--
--  Upon boot, this table must be populated with three rows - one for
--  each possible PacketCable 1.x admission control policy. Rows may be neither
--  created nor destroyed.
--
--=============================================================================

    cadPC1xAdmCtlMapTable   OBJECT-TYPE
    SYNTAX          SEQUENCE OF CadPC1xAdmCtlMapEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION     "Table of mappings of PacketCable 1.x to PacketCable 
                     Multimedia admission control policies"
    ::= { cadPCMibBase 80 }

cadPC1xAdmCtlMapEntry OBJECT-TYPE
    SYNTAX          CadPC1xAdmCtlMapEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION     "This entry contains mapping of one PacketCable 1.x 
                     admission policy to a PacketCable Multimedia policy."
    INDEX { cadPC1xAdmCtlMapPriority }
    ::= { cadPC1xAdmCtlMapTable 1 }

CadPC1xAdmCtlMapEntry ::= SEQUENCE {
    cadPC1xAdmCtlMapPriority    INTEGER,
    cadPCAdmCtlMapPriority      CadPCAdmCtlPriority
}

cadPC1xAdmCtlMapPriority OBJECT-TYPE 
    SYNTAX INTEGER { 
        undefined(1), 
        normal(2), 
        emergency(3) 
    }
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION     "PacketCable 1.x session class priority value"
    ::= { cadPC1xAdmCtlMapEntry 1 }

cadPCAdmCtlMapPriority OBJECT-TYPE
    SYNTAX          CadPCAdmCtlPriority
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION     "PacketCable Multimedia Priority value assigned to this row."
    ::= { cadPC1xAdmCtlMapEntry 2 }

--=============================================================================
--  cadPCInterfaceAdmCtlTable
--
--  The cadPCInterfaceAdmCtlTable provides the ability to manage the default 
--  PacketCable admission control policy per priority.
--
--  Upon boot, this table must be populated with rows per downstream and
--  rows per upstream for each CadPcAdmCtlPriority. Rows may be neither
--  created nor destroyed.
--
--=============================================================================
cadPCInterfaceAdmCtlTable   OBJECT-TYPE
    SYNTAX          SEQUENCE OF CadPCInterfaceAdmCtlEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION     "Table of Per-Priority PacketCable admission control 
                     policies.  There exists a row per cable downstream and 
                     per cable upstream for each of the CadPCAdmCtlPriorities.
                     For 1D:8U CAMs, the ifTypes populated are 128(downstream)
                     and 129(upstream). For DOCSIS 2.0 CAMs (2D:12U), the
                     ifTypes covered are 128(downstream) and 
                     205(logical upstream)."
    ::= { cadPCMibBase 85 }

cadPCInterfaceAdmCtlEntry   OBJECT-TYPE
    SYNTAX          CadPCInterfaceAdmCtlEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION     "This entry contains all of the default PacketCable 
                     admission policy data."
    INDEX { ifIndex, cadPCInterfaceAdmCtlPriority }
    ::= { cadPCInterfaceAdmCtlTable 1 }

CadPCInterfaceAdmCtlEntry ::= SEQUENCE {
    cadPCInterfaceAdmCtlPriority        CadPCAdmCtlPriority,
    cadPCInterfaceAdmCtlAllowedUsage    INTEGER,
    cadPCInterfaceAdmCtlReservedUsage   INTEGER
}

cadPCInterfaceAdmCtlPriority OBJECT-TYPE
    SYNTAX          CadPCAdmCtlPriority
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION     "Priority value assigned to this row."
    ::= { cadPCInterfaceAdmCtlEntry 1 }

cadPCInterfaceAdmCtlAllowedUsage OBJECT-TYPE
    SYNTAX          INTEGER (0..90)
    UNITS           "percent"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "Maximum percentage of resources that may be used by 
                     requests at the corresponding priority level. This is 
                     also the maximum amount of resources non-exclusively 
                     allocated to sessions of this type"
    REFERENCE       "'Cadant CMTS Requirements for PacketCable' requirement 
                     3.3.3.0.2"
    DEFVAL          { 50 }
    ::= { cadPCInterfaceAdmCtlEntry 2 }

cadPCInterfaceAdmCtlReservedUsage OBJECT-TYPE
    SYNTAX          INTEGER (0..90)
    UNITS           "percent"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "Minimum percentage of resources that may be used by 
                     requests at the corresponding priority level. This is 
                     also the maximum amount of resources exclusively 
                     allocated to sessions of this type. If the value of this
                     object is non-zero, then a portion of the bandwidth will
                     be set aside for this priority only - reducing the 
                     bandwidth that is available for normal data."
    REFERENCE       "'Cadant CMTS Requirements for PacketCable' requirement 
                     3.3.3.0.2"
    DEFVAL          { 0 }
    ::= { cadPCInterfaceAdmCtlEntry 3 }

--=============================================================================
--  cadPCCAMCblMacTable
--
--  The cadPCCAMCblMacTable provides the ability to manage PacketCable parameters on
--  a per-mac domain basis.
--
--  All objects are read-write
--
--=============================================================================
cadPCCAMCblMacTable   OBJECT-TYPE
    SYNTAX      SEQUENCE OF CadPCCAMCblMacEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "Table of Per-CAM PacketCable Data"
    ::= { cadPCMibBase 86 }

cadPCCAMCblMacEntry   OBJECT-TYPE
    SYNTAX      CadPCCAMCblMacEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "This entry contains all of the PacketCable data that
                is to be managed on a per-mac domain basis."
    INDEX { cadPCCAMCblMacIfIndex }    
    ::= { cadPCCAMCblMacTable 1 }

CadPCCAMCblMacEntry ::= SEQUENCE {
    cadPCCAMCblMacIfIndex                     InterfaceIndex,
    cadPCCAMCblMacFreeDSxAllowed              TruthValue,
    cadPCCblMacMaxOverloadDSaCalls            Unsigned32,
    cadPCCblMacMaxYellowOverloadDSaCalls      Unsigned32,
    cadPCCblMacMaxRedOverloadDSaCalls         Unsigned32
    }

cadPCCAMCblMacIfIndex OBJECT-TYPE
    SYNTAX          InterfaceIndex   
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION     "Indicates whether the authorization module will allow a
                    DOCSIS MAC Messaging Dynamic Services request (DSx) without
                    a gate-ID in an authorization block."
    ::= { cadPCCAMCblMacEntry 1 }

cadPCCAMCblMacFreeDSxAllowed OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "Indicates whether the authorization module will allow a
                    DOCSIS MAC Messaging Dynamic Services request (DSx) without
                    a gate-ID in an authorization block."
    DEFVAL          { true }
    ::= { cadPCCAMCblMacEntry 2 }

cadPCCblMacMaxOverloadDSaCalls  OBJECT-TYPE
    SYNTAX          Unsigned32(1..10000)
    UNITS           "connections per 10 seconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "the max number of connections we will allow per 10 second interval
                           when the system cpu is in a normal condition, i.e. no overload."
    DEFVAL          { 10000 }
    ::= { cadPCCAMCblMacEntry 3 }

cadPCCblMacMaxYellowOverloadDSaCalls  OBJECT-TYPE
    SYNTAX          Unsigned32(1..10000)
    UNITS           "connections per 10 seconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "the max number of connections we will allow per 10 second interval
                           when the system cpu is in a yellow overload condition."
    DEFVAL          { 10000 }
    ::= { cadPCCAMCblMacEntry 4 }

cadPCCblMacMaxRedOverloadDSaCalls  OBJECT-TYPE
    SYNTAX          Unsigned32(1..10000)
    UNITS           "connections per 10 seconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "the max number of connections we will allow per 10 second interval
                           when the system cpu is in a red overload condition."
    DEFVAL          { 3000 }
    ::= { cadPCCAMCblMacEntry 5 }

cadPCPEPIDHostname OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION     "If set to true, the PEP-ID on the COPS connection will set to the currently
                     configured hostname of the CMTS.  If false, the PEP-ID will will be set to
                     the local IP address of the COPS connection."
    DEFVAL          { false }
    ::= { cadPCMibBase 90 } 

END