CADANT-CMTS-NOTIFICATION-MIB DEFINITIONS ::= BEGIN

IMPORTS
        OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
            FROM SNMPv2-SMI
        DisplayString
            FROM SNMPv2-TC
        trapCounter, trapSeverity
            FROM CADANT-CMTS-EQUIPMENT-MIB
        cadNotification
            FROM CADANT-PRODUCTS-MIB
        ifIndex, ifAdminStatus, ifOperStatus, ifDescr
            FROM IF-MIB;

cadNotificationMib MODULE-IDENTITY
        LAST-UPDATED "201509140000Z" -- Sept 14, 2015
        ORGANIZATION "Cadant Inc"
        CONTACT-INFO "Cadant Technical Support "

        DESCRIPTION
        "This MIB defines object which are NOTIFICATION-TYPE and used to define  
          the SNMP Traps generated from C4 CMTS."

        REVISION "201509140000Z"
        DESCRIPTION  "Add cadLinkUp."

        REVISION "200605030000Z"
        DESCRIPTION  "Add cadIpdrNoPrimaryCollector, cadIpdrStreamingDisabled and
           cadIpdrReportCycleMissed."

        REVISION "200509280000Z"
        DESCRIPTION  "Add RIP2 authentication failure."

        REVISION "200303260000Z"
        DESCRIPTION  "Renamed RADIUS traps so that they can also be used by TACACS+."

        REVISION "200207240000Z"
        DESCRIPTION  "Inital version. Add AAA/Security related traps."

        ::= { cadNotification 1 }

cadTrapMibObjects OBJECT IDENTIFIER   ::= { cadNotificationMib 1 } 
cadTraps	   OBJECT IDENTIFIER   ::= { cadTrapMibObjects 0 }
cadTrapsInfo   OBJECT IDENTIFIER   ::= { cadTrapMibObjects 1 }

securityInfo OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS accessible-for-notify
	STATUS current
	DESCRIPTION
		"The detail security failure information"
	::= { cadTrapsInfo 1 }

ipdrInfo OBJECT-TYPE
	SYNTAX DisplayString
	MAX-ACCESS accessible-for-notify
	STATUS current
	DESCRIPTION
		"The detail IPDR failure information"
	::= { cadTrapsInfo 2 }

aaaServerUnreachableTrap NOTIFICATION-TYPE
			 OBJECTS {
				trapCounter,
				trapSeverity,
				securityInfo
			 }
             STATUS  current
             DESCRIPTION
             "An event to report that the AAA (RADIUS or TACACS+) server is not responding"
         ::= { cadTraps 1}

aaaServerGroupUnreachableTrap NOTIFICATION-TYPE
			 OBJECTS {
				trapCounter,
				trapSeverity,
				securityInfo
			 }
             STATUS  current
             DESCRIPTION
             "An event to report that all the hosts in the AAA (RADIUS or TACACS+) server 
			 group are not responding"
         ::= { cadTraps 2}

aaaServerAuthFailTrap NOTIFICATION-TYPE
			 OBJECTS {
				trapCounter,
				trapSeverity,
				securityInfo
			 }
             STATUS  current
             DESCRIPTION
             "An event to report that AAA (RADIUS or TACACS+) server rejected the authentication request"
         ::= { cadTraps 3}

secuLocalAuthFailTrap NOTIFICATION-TYPE
			 OBJECTS {
				trapCounter,
				trapSeverity,
				securityInfo
			 }
             STATUS  current
             DESCRIPTION
             "An event to report that local password authentication failed"
         ::= { cadTraps 4}
	
secuLineAuthFailTrap NOTIFICATION-TYPE
			 OBJECTS {
				trapCounter,
				trapSeverity,
				securityInfo
			 }
             STATUS  current
             DESCRIPTION
             "An event to report that line password authentication failed"
         ::= { cadTraps 5 }

rip2AuthFailTrap NOTIFICATION-TYPE
			 OBJECTS {
				trapCounter,
				trapSeverity,
				securityInfo
			 }
             STATUS  current
             DESCRIPTION
             "An event to report rip2 authentication failed."
         ::= { cadTraps 6 }

cadIpdrNoPrimaryCollector NOTIFICATION-TYPE
			 OBJECTS {
				trapCounter,
				trapSeverity,
				ipdrInfo
			 }
             STATUS  current
             DESCRIPTION
             "An event to report IPDR Streaming is enabled but there is no primary collector connected."
         ::= { cadTraps 7 }

cadIpdrStreamingDisabled NOTIFICATION-TYPE
			 OBJECTS {
				trapCounter,
				trapSeverity,
				ipdrInfo
			 }
             STATUS  current
             DESCRIPTION
             "An event to report IPDR Streaming function has been turned off."
         ::= { cadTraps 8 }

cadIpdrReportCycleMissed NOTIFICATION-TYPE
			 OBJECTS {
				trapCounter,
				trapSeverity,
				ipdrInfo
			 }
             STATUS  current
             DESCRIPTION
             "An event to report CMTS was not able to start the scheduled IPDR report cycle session on time.
	      This may be due to system or network load or the lack of primary collector connection."
         ::= { cadTraps 9 }

cadLinkUp NOTIFICATION-TYPE
    OBJECTS { ifIndex, ifAdminStatus, ifOperStatus, ifDescr }
    STATUS  current
    DESCRIPTION
            "This is to expand standard linkUp trap to include ifDescr.
            A linkUp trap signifies that the SNMP entity, acting in an
            agent role, has detected that the ifOperStatus object for
            one of its communication links left the down state and
            transitioned into some other state (but not into the
            notPresent state).  This other state is indicated by the
            included value of ifOperStatus."
    ::= { cadTraps 10 }
END