CADANT-CMTS-BPI2-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, Integer32
	    FROM SNMPv2-SMI
    TruthValue
        FROM SNMPv2-TC
    ifIndex
	    FROM IF-MIB
    cadSystem
        FROM CADANT-PRODUCTS-MIB;

cadBpi2Mib MODULE-IDENTITY
	LAST-UPDATED "201407300000Z"  -- July 30, 2014
	ORGANIZATION "Cadant Inc"
	CONTACT-INFO "Cadant Technical Support"
	DESCRIPTION "Cadant Bpi+ mib derived from the DOCS-BPI2-MIB"

    REVISION     "201407300000Z"  -- July 30, 2014
    DESCRIPTION
        "Add cadBpi2CmtsAES128Enable." 
    REVISION     "200612180000Z"
    DESCRIPTION
        "Add default value to cadBpi2CmtsDefaultAuthLifetime = 604800
                              cadBpi2CmtsDefaultTEKLifetime  = 43200
                              cadBpi2CmtsDefaultSelfSignedManufCertTrust = untrusted
                              cadBpi2CmtsCheckCertValidityPeriods = false"    		
	::= { cadSystem 5 }

--
--  The BPI+ CMTS base table, indexed by ifindex
--

cadBpi2CmtsBaseTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF CadBpi2CmtsBaseEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
            ""
    ::= { cadBpi2Mib 1 }

cadBpi2CmtsBaseEntry OBJECT-TYPE
    SYNTAX     CadBpi2CmtsBaseEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
            ""
    INDEX      { ifIndex }
    ::= { cadBpi2CmtsBaseTable 1 }

CadBpi2CmtsBaseEntry ::= SEQUENCE {
    cadBpi2CmtsDefaultAuthLifetime        Integer32,
    cadBpi2CmtsDefaultTEKLifetime         Integer32,
    cadBpi2CmtsDefaultSelfSignedManufCertTrust         INTEGER,
    cadBpi2CmtsCheckCertValidityPeriods   TruthValue
}

cadBpi2CmtsDefaultAuthLifetime    OBJECT-TYPE
     SYNTAX         Integer32 (1..6048000)
     UNITS          "seconds"
     MAX-ACCESS     read-write
     STATUS         current
     DESCRIPTION
          "The value of this object is the default lifetime, in
     seconds, the CMTS assigns to a new authorization key."
     REFERENCE
          "DOCSIS Baseline Privacy Plus Interface Specification,
     Appendix A.2."
     DEFVAL {604800}
     ::= { cadBpi2CmtsBaseEntry 1 }

cadBpi2CmtsDefaultTEKLifetime     OBJECT-TYPE
     SYNTAX         Integer32 (1..604800)
     UNITS          "seconds"
     MAX-ACCESS     read-write
     STATUS         current
     DESCRIPTION
          "The value of this object is the default lifetime, in
     seconds, the CMTS assigns to a new Traffic Encryption Key
     (TEK)."
     REFERENCE
          "DOCSIS Baseline Privacy Plus Interface Specification,
     Appendix A.2."
     DEFVAL {43200}
     ::= { cadBpi2CmtsBaseEntry 2 }

cadBpi2CmtsDefaultSelfSignedManufCertTrust  OBJECT-TYPE
     SYNTAX    INTEGER {
               trusted (1),
               untrusted (2)
               }
     MAX-ACCESS     read-write
     STATUS         current
     DESCRIPTION
          "This object determines the default trust of all (new)
     self-signed manufacturer certificates obtained after setting
     the object."
     REFERENCE
          "DOCSIS Baseline Privacy Plus Interface Specification,
     Section 9.4.1"
     DEFVAL {untrusted}
     ::= { cadBpi2CmtsBaseEntry 3 }

cadBpi2CmtsCheckCertValidityPeriods    OBJECT-TYPE
     SYNTAX         TruthValue
     MAX-ACCESS     read-write
     STATUS         current
     DESCRIPTION
          "Setting this object to TRUE causes all certificates
     obtained thereafter to have their validity periods (and their
     chain's validity periods) checked against the current time of
     day.  A FALSE setting will cause all certificates obtained
     thereafter to not have their validity periods (nor their
     chain's validity periods) checked against the current time of
     day."
     REFERENCE
          "DOCSIS Baseline Privacy Plus Interface Specification,
     Section 9.4.2"
     DEFVAL {false}
     ::= { cadBpi2CmtsBaseEntry 4 }

cadBpi2CmtsConfig  OBJECT IDENTIFIER ::= { cadBpi2Mib 2 }

cadBpi2CmtsAES128Enable OBJECT-TYPE
    SYNTAX  TruthValue
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
        "Enables AES-128 Cryptography Suite for BPI+ when true."
    DEFVAL { false }
    ::= { cadBpi2CmtsConfig  1}


END