-- ACMEPACKET-ENVMON-MIB: Acme Packet Environmental Monitor MIB file
--
-- February 2004
--
-- Copyright (c) by Acme Packet, Inc.
----------------------------------------------------------------------
ACMEPACKET-ENVMON-MIB DEFINITIONS ::= BEGIN

IMPORTS
        MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
        Gauge32, Integer32
                FROM SNMPv2-SMI
        TEXTUAL-CONVENTION, DisplayString, TruthValue
                FROM SNMPv2-TC
        MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
                FROM SNMPv2-CONF
        acmepacketMgmt
                FROM ACMEPACKET-SMI
        ApHardwareModuleFamily, ApRedundancyState, ApPhyPortType,
	ApPresence
                FROM ACMEPACKET-TC;

apEnvMonModule MODULE-IDENTITY
        LAST-UPDATED    "201207160000Z"
        ORGANIZATION    "Acme Packet, Inc"
        CONTACT-INFO   
			  "       Customer Service
                        Postal: Acme Packet, Inc
                                100 Crosby Drive
                                Bedford, MA 01730
                                US
                        Tel:    1-781-328-4400
                        E-mail: support@acmepacket.com"
              
        DESCRIPTION
                "The MIB module to describe the status of the Environmental
                Monitor on the devices."
        REVISION "201207160000Z" 
        DESCRIPTION
                "Updated contact information."
        ::= {acmepacketMgmt 3}

ApEnvMonState ::= TEXTUAL-CONVENTION
        STATUS          current
        DESCRIPTION
               "Represents the state of a device being monitored.
                 Valid values are:
                
                initial (1):    the environment is at initial state.

                normal (2) :    the environment is good, such as low
                                temperature.

                minor  (3) :    the environment is not good, such as:
                                fan speed is more than minor alarm threshold,
				but less than major alarm threshold.

                major  (4) :    the environment is bad, such as:
                                fan speed is more than major alarm threshold, 
				but less than critical alarm threshold.

                critical(5):    the environment is very bad, such as
                                Fan speed is more than critical threshold.

                shutdown(6):    the environment is the worst, the system
                                should be shutdown immediately.

                notPresent(7):  the environmental monitor is not present,
                                such as temperature sensors do not exist.

                notFunctioning(8): the environmental monitor does not
                                   function properly, such as
                                   1. I2C fail
                                   2. a temperature sensor generates a abnormal
                                      data like 1000 C.
		unknown(9) :    can not get the information due to
				internal error.
                "
        SYNTAX INTEGER {
			initial(1),
                        normal(2),
                        minor(3),
                        major(4),
                        critical(5),
                        shutdown(6),
                        notPresent(7),
                        notFunctioning(8),
			unknown(9)
                        }

apEnvMonObjects OBJECT IDENTIFIER ::= {apEnvMonModule 1}
 
apEnvMonI2CState OBJECT-TYPE
        SYNTAX          ApEnvMonState
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
                "the state of environment monitor located in the chassis."
        ::= {apEnvMonObjects 1}


-- Voltage table
apEnvMonVoltageObjects OBJECT IDENTIFIER ::= { apEnvMonObjects 2 }

apEnvMonVoltageStatusTable OBJECT-TYPE
        SYNTAX     SEQUENCE OF ApEnvMonVoltageStatusEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "The table of voltage status maintained by the environmental
                monitor."
        ::= { apEnvMonVoltageObjects 1 }

apEnvMonVoltageStatusEntry OBJECT-TYPE
        SYNTAX     ApEnvMonVoltageStatusEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "An entry in the voltage status table, representing the status
                of the associated testpoint maintained by the environmental
                monitor."
        INDEX      { apEnvMonVoltageStatusIndex }
        ::= { apEnvMonVoltageStatusTable 1 }

ApEnvMonVoltageStatusEntry ::=
        SEQUENCE {
                apEnvMonVoltageStatusIndex       Integer32 (1..2147483647),
                apEnvMonVoltageStatusType        INTEGER,
                apEnvMonVoltageStatusDescr       DisplayString,
                apEnvMonVoltageStatusValue       Integer32,
                apEnvMonVoltageState             ApEnvMonState,
                apEnvMonVoltageSlotID            INTEGER,
                apEnvMonVoltageSlotType          ApHardwareModuleFamily
        }

apEnvMonVoltageStatusIndex OBJECT-TYPE
        SYNTAX     Integer32 (1..2147483647)
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "Unique index for the testpoint being instrumented.
                This index is for SNMP purposes only, and has no
                intrinsic meaning."
        ::= { apEnvMonVoltageStatusEntry 1 }

apEnvMonVoltageStatusType OBJECT-TYPE
        SYNTAX     INTEGER {
	                unknown(0),

                        v2p5 (1),
                        v3p3 (2),
                        v5   (3),
                        cpu  (4),

			v1(5),
			v1p1(6),
			v1p15(7),
			v1p2(8),
			v1p212(9),
			v1p25(10),
			v1p3(11),
			v1p5(12),
			v1p8(13),

			v2p6(14),
                        v3p3aux(15)
                   }
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The entity part type from which the voltage value is from
		v2p5- 2.5V sensor: L3 cache core voltage; micro-processor and 
		co-processoor I/O voltage; FPGA memories I/O voltage.
		v3p3 - 3.3V sensor: general TTL supply rail; control logic;
		micro-processor;  micro-processor and co-processor; SDRAM
		v5   - 5V sensor: Fans; micro-processor core voltage regulator.
		CPU  - CPU voltage micro-processor core voltage."
        ::= { apEnvMonVoltageStatusEntry 2 }

apEnvMonVoltageStatusDescr OBJECT-TYPE
        SYNTAX     DisplayString (SIZE (0..64))
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "Textual description of the voltage being instrumented.
                This description is a short textual label, suitable as a
                human-sensible identification for the rest of the
                information in the entry."
        ::= { apEnvMonVoltageStatusEntry 3 }

apEnvMonVoltageStatusValue OBJECT-TYPE
        SYNTAX     Integer32
        UNITS      "millivolts"
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The current measurement of voltage if avaiable.
		The value is expressed as the 
		integer in millivolts unit."
        ::= { apEnvMonVoltageStatusEntry 4 }


apEnvMonVoltageState OBJECT-TYPE
        SYNTAX     ApEnvMonState
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The current state of the testpoint being instrumented."
        ::= { apEnvMonVoltageStatusEntry 5 }


apEnvMonVoltageSlotID OBJECT-TYPE
        SYNTAX     INTEGER
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The slot this voltage is found on."
        ::= { apEnvMonVoltageStatusEntry 6 }


apEnvMonVoltageSlotType OBJECT-TYPE
        SYNTAX     ApHardwareModuleFamily
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The type of module found in this slot."
        ::= { apEnvMonVoltageStatusEntry 7 }


-- Temperature Table
apEnvMonTemperatureObjects OBJECT IDENTIFIER ::= { apEnvMonObjects 3 }

apEnvMonTemperatureStatusTable OBJECT-TYPE
        SYNTAX     SEQUENCE OF ApEnvMonTemperatureStatusEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "The table of ambient temperature status maintained by the
                environmental monitor."
        ::= { apEnvMonTemperatureObjects 1 }

apEnvMonTemperatureStatusEntry OBJECT-TYPE
        SYNTAX     ApEnvMonTemperatureStatusEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "An entry in the ambient temperature status table, representing
                the status of the associated testpoint maintained by the
                environmental monitor."
        INDEX      { apEnvMonTemperatureStatusIndex }
        ::= { apEnvMonTemperatureStatusTable 1 }

ApEnvMonTemperatureStatusEntry ::=
        SEQUENCE {
                apEnvMonTemperatureStatusIndex       Integer32 (1..2147483647),
                apEnvMonTemperatureStatusType        INTEGER,
                apEnvMonTemperatureStatusDescr       DisplayString,
                apEnvMonTemperatureStatusValue       Integer32,                
                apEnvMonTemperatureState             ApEnvMonState,
                apEnvMonTemperatureSlotID            INTEGER,
                apEnvMonTemperatureSlotType          ApHardwareModuleFamily
        }


apEnvMonTemperatureStatusIndex OBJECT-TYPE
        SYNTAX     Integer32 (1..2147483647)
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "Unique index for the testpoint being instrumented.
                This index is for SNMP purposes only, and has no
                intrinsic meaning."
        ::= { apEnvMonTemperatureStatusEntry 1 }


apEnvMonTemperatureStatusType OBJECT-TYPE
        SYNTAX     INTEGER {
                        ds1624sMain(1),
			ds1624sCPU(2),
			lm84(3),
			lm75(4),
			lm75Main(5),
			lm75Cpu(6),
			lm75Phy(7)
                   }
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The entity part type from which the temperature value is from"
        ::= { apEnvMonTemperatureStatusEntry 2 }

apEnvMonTemperatureStatusDescr OBJECT-TYPE
        SYNTAX     DisplayString (SIZE (0..64))
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "Textual description of the temperature being instrumented.
                This description is a short textual label, suitable as a
                human-sensible identification for the rest of the
                information in the entry."
        ::= { apEnvMonTemperatureStatusEntry 3 }

apEnvMonTemperatureStatusValue OBJECT-TYPE
        SYNTAX     Integer32
        UNITS      "degrees Celsius"
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The current measurement of the testpoint being instrumented."
        ::= { apEnvMonTemperatureStatusEntry 4 }

apEnvMonTemperatureState OBJECT-TYPE
        SYNTAX     ApEnvMonState
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The current state of the testpoint being instrumented."
        ::= { apEnvMonTemperatureStatusEntry 5 }

apEnvMonTemperatureSlotID OBJECT-TYPE
        SYNTAX     INTEGER
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The slot this temperature is found on."
        ::= { apEnvMonTemperatureStatusEntry 6 }


apEnvMonTemperatureSlotType OBJECT-TYPE
        SYNTAX     ApHardwareModuleFamily
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The type of module found in this slot."
        ::= { apEnvMonTemperatureStatusEntry 7 }


 -- Fan table
apEnvMonFanObjects OBJECT IDENTIFIER ::= { apEnvMonObjects 4 }

apEnvMonFanStatusTable OBJECT-TYPE
        SYNTAX     SEQUENCE OF ApEnvMonFanStatusEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "The table of fan status maintained by the environmental
                monitor."
        ::= { apEnvMonFanObjects 1 }

apEnvMonFanStatusEntry OBJECT-TYPE
        SYNTAX     ApEnvMonFanStatusEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "An entry in the fan status table, representing the status of
                the associated fan maintained by the environmental monitor."
        INDEX   { apEnvMonFanStatusIndex }
        ::= { apEnvMonFanStatusTable 1 }

ApEnvMonFanStatusEntry ::=
        SEQUENCE {
                apEnvMonFanStatusIndex       Integer32 (1..2147483647),
		apEnvMonFanStatusType        INTEGER,
                apEnvMonFanStatusDescr       DisplayString,
                apEnvMonFanStatusValue       Gauge32,
                apEnvMonFanState             ApEnvMonState,
                apEnvMonFanSlotID            INTEGER
        }

apEnvMonFanStatusIndex OBJECT-TYPE
        SYNTAX     Integer32 (1..2147483647)
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "Unique index for the fan being instrumented.
                This index is for SNMP purposes only."
        ::= { apEnvMonFanStatusEntry 1 }

apEnvMonFanStatusType OBJECT-TYPE
        SYNTAX     INTEGER {
                        left   (0),
                        middle (1),
                        right  (2),
			slot   (3)
                   }
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The entity part type from which the fan value is from.
		The left and right at the base when one faces the front
		of the SD.

		Next-generation products contain replaceable fans contained
		in chassis slots."
        ::= { apEnvMonFanStatusEntry 2 }

apEnvMonFanStatusDescr OBJECT-TYPE
        SYNTAX     DisplayString (SIZE (0..64))
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "Textual description of the fan being instrumented.
                This description is a short textual label, suitable as a
                human-sensible identification for the rest of the
                information in the entry."
        ::= { apEnvMonFanStatusEntry 3 }

apEnvMonFanStatusValue OBJECT-TYPE
        SYNTAX     Gauge32
        UNITS      "%"
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The current percentage measurement of the fan speed."
        ::= { apEnvMonFanStatusEntry 4 }

apEnvMonFanState OBJECT-TYPE
        SYNTAX     ApEnvMonState
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The current state of the fan being instrumented."
        ::= { apEnvMonFanStatusEntry 5 }

apEnvMonFanSlotID OBJECT-TYPE
        SYNTAX     INTEGER
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The slot this van is found in.  zero is returned if
		this fan is not of apEnvMonFanStatusType slot(3)."
        ::= { apEnvMonFanStatusEntry 6 }


-- Power supply table
-- Now no power info can be got, except the power is presented or not
apEnvMonPowerSupplyObjects OBJECT IDENTIFIER ::= { apEnvMonObjects 5 }

apEnvMonPowerSupplyStatusTable OBJECT-TYPE
        SYNTAX     SEQUENCE OF ApEnvMonPowerSupplyStatusEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "The table of power supply status maintained by the
                environmental monitor card."
        ::= { apEnvMonPowerSupplyObjects 1  }

apEnvMonPowerSupplyStatusEntry OBJECT-TYPE
        SYNTAX     ApEnvMonPowerSupplyStatusEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "An entry in the power supply status table, representing the
                status of the associated power supply maintained by the
                environmental monitor card."
        INDEX   { apEnvMonPowerSupplyStatusIndex }
        ::= { apEnvMonPowerSupplyStatusTable 1  }

ApEnvMonPowerSupplyStatusEntry ::=
        SEQUENCE {
                apEnvMonPowerSupplyStatusIndex    Integer32 (1..2147483647),
		apEnvMonPowerSupplyStatusType     INTEGER,
                apEnvMonPowerSupplyStatusDescr    DisplayString,
                apEnvMonPowerSupplyState          ApEnvMonState
        }

apEnvMonPowerSupplyStatusIndex OBJECT-TYPE
        SYNTAX     Integer32 (1..2147483647)
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "Unique index for the power supply being instrumented.
                This index is for SNMP purposes only."
        ::= { apEnvMonPowerSupplyStatusEntry 1 }

apEnvMonPowerSupplyStatusType OBJECT-TYPE
        SYNTAX     INTEGER {
                        left  (0),
                        right (1),
			slot  (3)   -- slot enum is 3 to make all slot
				    -- enums align
                   }
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The entity part type from which the power status is from. 
		0=left:power supply A, 1=right:power supply B.
		3=slot: power supply is contained in the slot corresponding
		to apEnvMonPowerSowerSupplyStatusIndex"
        ::= { apEnvMonPowerSupplyStatusEntry 2 }

apEnvMonPowerSupplyStatusDescr OBJECT-TYPE
        SYNTAX     DisplayString (SIZE (0..64))
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "Textual description of the power supply being instrumented.
                This description is a short textual label, suitable as a
                human-sensible identification for the rest of the
                information in the entry."
        ::= { apEnvMonPowerSupplyStatusEntry 3 }

apEnvMonPowerSupplyState OBJECT-TYPE
        SYNTAX     ApEnvMonState
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The current state of the power supply being instrumented:
                     normal or notPresent"
        ::= { apEnvMonPowerSupplyStatusEntry 4 }


-- Phy table 
apEnvMonPhyCardObjects OBJECT IDENTIFIER ::= { apEnvMonObjects 6 }

apEnvMonPhyCardStatusTable OBJECT-TYPE
        SYNTAX     SEQUENCE OF ApEnvMonPhyCardStatusEntry
        MAX-ACCESS not-accessible
        STATUS     deprecated
        DESCRIPTION
               "THIS TABLE IS BEING DEPRECATED IN FAVOR OF THE
		MORE GENERIC apEnvMonCardTable.

		Please Note:  in the generic card table, a phy card
		is referred to as an 'niu' (network interfacing unit).

                The table of phy card status maintained by the
                environmental monitor."
        ::= { apEnvMonPhyCardObjects 1 }

apEnvMonPhyCardStatusEntry OBJECT-TYPE
        SYNTAX     ApEnvMonPhyCardStatusEntry
        MAX-ACCESS not-accessible
        STATUS     deprecated
        DESCRIPTION
	       "An entry in the phy status table, representing the
                status of the associated phy maintained by the
                environmental monitor."
        INDEX   { apEnvMonPhyCardStatusIndex }
        ::= { apEnvMonPhyCardStatusTable 1  }

ApEnvMonPhyCardStatusEntry ::=
        SEQUENCE {
                apEnvMonPhyCardStatusIndex    Integer32 (1..2147483647),
	 	apEnvMonPhyCardStatusType     INTEGER,
                apEnvMonPhyCardStatusDescr    DisplayString,
                apEnvMonPhyCardState          ApEnvMonState
        }

apEnvMonPhyCardStatusIndex OBJECT-TYPE
        SYNTAX     Integer32 (1..2147483647)
        MAX-ACCESS not-accessible
        STATUS     deprecated
        DESCRIPTION
                "Unique index for the phy being instrumented.
                This index is for SNMP purposes only."
        ::= { apEnvMonPhyCardStatusEntry 1 }

apEnvMonPhyCardStatusType OBJECT-TYPE
        SYNTAX     INTEGER {
                        left  (0),
                        right (1),
			slot  (3)   -- slot enum is 3 to make
			            -- all slot enums align
			}
        MAX-ACCESS read-only
        STATUS     deprecated
        DESCRIPTION
                "The entity part type from which the phy card is from. 
                0=left:card A, 1=right:card B, 3=only card.
		3=slot: phyCard is contained in the slot corresponding
		to apEnvMonPhyCardStatusIndex"
        ::= { apEnvMonPhyCardStatusEntry 2 }

apEnvMonPhyCardStatusDescr OBJECT-TYPE
        SYNTAX     DisplayString (SIZE (0..32))
        MAX-ACCESS read-only
        STATUS     deprecated
        DESCRIPTION
                "Textual description of the phy being instrumented.
                This description is a short textual label, suitable as a
                human-sensible identification for the rest of the
                information in the entry."
        ::= { apEnvMonPhyCardStatusEntry 3 }

apEnvMonPhyCardState OBJECT-TYPE
        SYNTAX     ApEnvMonState
        MAX-ACCESS read-only
        STATUS     deprecated
        DESCRIPTION
                "The current state of the phy being instrumented:
		     normal or notPresent"
        ::= { apEnvMonPhyCardStatusEntry 4 }


apEnvMonCardObjects OBJECT IDENTIFIER ::= { apEnvMonObjects 7 }

---------------------------------------
-- Card Table
---------------------------------------
apEnvMonCardTable	OBJECT-TYPE
	SYNTAX      SEQUENCE OF ApEnvMonCardEntry
	MAX-ACCESS  not-accessible
	STATUS      current
	DESCRIPTION  
		"List of Cards in the chassis"
	::= { apEnvMonCardObjects 1 } 

apEnvMonCardEntry	OBJECT-TYPE
	SYNTAX      ApEnvMonCardEntry
	MAX-ACCESS  not-accessible
	STATUS      current
	DESCRIPTION  
		"A single card in the chassis"
	INDEX	{ apEnvMonCardSlot }
	::= { apEnvMonCardTable 1 } 

ApEnvMonCardEntry	::=
	SEQUENCE {
		apEnvMonCardSlot		INTEGER,
		apEnvMonCardType		ApHardwareModuleFamily,
		apEnvMonCardDescr		DisplayString,
		apEnvMonCardHealthScore		INTEGER,
		apEnvMonCardState		ApEnvMonState,
		apEnvMonCardRedundancy		ApRedundancyState
	}


apEnvMonCardSlot	OBJECT-TYPE
	SYNTAX      INTEGER
	MAX-ACCESS  read-only
	STATUS      current
	DESCRIPTION  
		"Slot number of this card.  Please note that the
		 slot number is zero-based, i.e. they are numbered 0-n."
	::= { apEnvMonCardEntry 1 } 

apEnvMonCardType	OBJECT-TYPE
	SYNTAX      ApHardwareModuleFamily
	MAX-ACCESS  read-only
	STATUS      current
	DESCRIPTION  
		"The card type"
	::= { apEnvMonCardEntry 2 } 

apEnvMonCardDescr	OBJECT-TYPE
	SYNTAX      DisplayString
	MAX-ACCESS  read-only
	STATUS      current
	DESCRIPTION  
		"A text description of this card"
	::= { apEnvMonCardEntry 3 } 

apEnvMonCardHealthScore	OBJECT-TYPE
	SYNTAX      INTEGER
	MAX-ACCESS  read-only
	STATUS      current
	DESCRIPTION  
		"The health score of this card"
	::= { apEnvMonCardEntry 4 } 

apEnvMonCardState	OBJECT-TYPE
	SYNTAX      ApEnvMonState
	MAX-ACCESS  read-only
	STATUS      current
	DESCRIPTION  
		"the current state of this card"
	::= { apEnvMonCardEntry 5 } 

apEnvMonCardRedundancy         OBJECT-TYPE
        SYNTAX      ApRedundancyState
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
               "Redundancy state of the card"
        ::= { apEnvMonCardEntry 6 }


---------------------------------------
-- CPU Core Table
---------------------------------------
apEnvMonCpuCoreTable	OBJECT-TYPE
	SYNTAX      SEQUENCE OF ApEnvMonCpuCoreEntry
	MAX-ACCESS  not-accessible
	STATUS      current
	DESCRIPTION  
		"List of cores per CPU in the chassis"
	::= { apEnvMonCardObjects 2 } 

apEnvMonCpuCoreEntry	OBJECT-TYPE
	SYNTAX      ApEnvMonCpuCoreEntry
	MAX-ACCESS  not-accessible
	STATUS      current
	DESCRIPTION  
		"A single CPU core in the chassis"
	INDEX	{ apEnvMonCardSlot,
		  apEnvMonCpuCoreIndex
	        }
	::= { apEnvMonCpuCoreTable 1 } 

ApEnvMonCpuCoreEntry	::=
	SEQUENCE {
		apEnvMonCpuCoreIndex	INTEGER,
		apEnvMonCpuCoreDescr	DisplayString,
		apEnvMonCpuCoreUsage    Gauge32,
		apEnvMonCpuCoreState	INTEGER,
		apEnvMonCpuCoreRamDescr	DisplayString,
		apEnvMonCpuCoreRamUsage Gauge32
	}

apEnvMonCpuCoreIndex	OBJECT-TYPE
	SYNTAX      INTEGER
	MAX-ACCESS  read-only
	STATUS      current
	DESCRIPTION  
		"the core index on the CPU"
	::= { apEnvMonCpuCoreEntry 1 } 

apEnvMonCpuCoreDescr	OBJECT-TYPE
	SYNTAX      DisplayString
	MAX-ACCESS  read-only
	STATUS      current
	DESCRIPTION  
		"the cpu core descriptor"
	::= { apEnvMonCpuCoreEntry 2 } 

apEnvMonCpuCoreUsage OBJECT-TYPE
        SYNTAX     Gauge32
        UNITS      "%"
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The current percentage of use for the CPU core."
        ::= { apEnvMonCpuCoreEntry 3 }

apEnvMonCpuCoreState OBJECT-TYPE
        SYNTAX     INTEGER {
	              unknown(0),
		      present(1),                
		      booting(2),
		      registered(3),
		      readywait(4),
		      ready(5),
		      bootTimeout(6),
		      registerTimeout(7),
		      manifestTimeout(8),
		      readyTimeout(9),
			  healthWait(101),
			  healthRcvd(102),
			  becomingActive(201),
			  becomingStandby(202),
			  becomingOOS(203),
			  active(204),
			  standby(205),
			  oos(206),
			  activeTimeout(207),
			  standbyTimeout(208),
			  oosTimeout(209),
			  resetting(401),
			  reset(402),
			  resetTimeout(403),
			  shuttingDown(404),
			  shutOff(405),
			  shutdownTimeout(406)
		   }
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The state of this CPU core."
        ::= { apEnvMonCpuCoreEntry 4 }


apEnvMonCpuCoreRamDescr	OBJECT-TYPE
	SYNTAX      DisplayString
	MAX-ACCESS  read-only
	STATUS      current
	DESCRIPTION  
		"The cpu core RAM descriptor"
	::= { apEnvMonCpuCoreEntry 5 } 

apEnvMonCpuCoreRamUsage OBJECT-TYPE
        SYNTAX     Gauge32
        UNITS      "%"
        MAX-ACCESS read-only
        STATUS     current
        DESCRIPTION
                "The current percentage of use for the CPU core RAM."
        ::= { apEnvMonCpuCoreEntry 6 }

apEnvMonMIBNotificationEnables OBJECT IDENTIFIER ::= { apEnvMonModule 2 }

apEnvMonEnableStatChangeNotif OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
               "This variable indicates whether the system
                produces any of the traps generated by this mib.
                A false value will prevent them from being generated by
                this system."
--        DEFVAL { false }
        ::= { apEnvMonMIBNotificationEnables 1 }



-- Notification MIBs
apEnvMonNotificationObjects OBJECT IDENTIFIER ::= { apEnvMonModule 3 }

apEnvMonTrapInstance                 OBJECT-TYPE
        SYNTAX                  OBJECT IDENTIFIER
        MAX-ACCESS              accessible-for-notify
        STATUS                  current
        DESCRIPTION
        "The object ID of the item which value is exceeds its monitoring
        threshold. If the item is within a table, this OID is the instance 
	of this item's index within its table.
	For exmple, 

	1. if the state of 2.5v voltage changes, the item is apEnvMonVoltageState.
	the trap instance OID is apEnvMonVoltageState.1, 
	where the ending 1 is the instance index of 2.5v entry. 
	The numeric form is 1.3.6.1.4.1.9148.3.3.1.2.1.1.5.1

	2. if the state of mainboard temperature changes, the trap instance
	OID is apEnvMonTemperatureState.x, where x is the index
	which makes apEnvMonTemperatureStatusType.x = lm75Main(5).

	3. if the state of left fan changes, the trap instance OID is 
	apEnvMonFanState.y, where y is the index which 
	makes apEnvMonFanStatusType.y = left (0).

	If the item is scalar, the OID is the instance OID of this item,
	For example,

	If the I2C state changes, the OID is apEnvMonI2CState.0
	"
        ::= { apEnvMonNotificationObjects 1 }

apEnvMonTrapPreviousState       OBJECT-TYPE
        SYNTAX                  ApEnvMonState
        MAX-ACCESS              accessible-for-notify
        STATUS                  current
        DESCRIPTION
        "The previous state of the object."
        ::= { apEnvMonNotificationObjects 2 }

apEnvMonTrapCurrentState        OBJECT-TYPE
        SYNTAX                  ApEnvMonState
        MAX-ACCESS              accessible-for-notify
        STATUS                  current
        DESCRIPTION
        "The current state of the object which causes the trap to occur."
        ::= { apEnvMonNotificationObjects 3 }

apEnvMonTrapSlotID        OBJECT-TYPE
        SYNTAX    	  INTEGER
        MAX-ACCESS              accessible-for-notify
        STATUS                  current
        DESCRIPTION
        "The slotID which causes the trap to occur."
        ::= { apEnvMonNotificationObjects 4 }

apEnvMonTrapSlotType        OBJECT-TYPE
        SYNTAX    	ApHardwareModuleFamily
        MAX-ACCESS              accessible-for-notify
        STATUS                  current
        DESCRIPTION
        "The slot type which causes the trap to occur."
        ::= { apEnvMonNotificationObjects 5 }

apEnvMonTrapPortType        OBJECT-TYPE
        SYNTAX    		ApPhyPortType
        MAX-ACCESS              accessible-for-notify
        STATUS                  current
        DESCRIPTION
        "The port type which causes the trap to occur."
        ::= { apEnvMonNotificationObjects 6 }

apEnvMonTrapPresence        OBJECT-TYPE
        SYNTAX    		ApPresence
        MAX-ACCESS              accessible-for-notify
        STATUS                  current
        DESCRIPTION
        "The state which causes the trap to occur."
        ::= { apEnvMonNotificationObjects 7 }

apEnvMonTrapPortID        OBJECT-TYPE
        SYNTAX    		Integer32
        MAX-ACCESS              accessible-for-notify
        STATUS                  current
        DESCRIPTION
        "The ID of the port which causes the trap to occur."
        ::= { apEnvMonNotificationObjects 8 }


-- the following two OBJECT IDENTIFIERS are used to define SNMPv2 Notifications
-- that are backward compatible with SNMPv1 Traps.
apEnvMonMIBNotificationPrefix OBJECT IDENTIFIER ::= { apEnvMonModule 4 }
apEnvMonMIBNotifications OBJECT IDENTIFIER ::= { apEnvMonMIBNotificationPrefix 0 }

apEnvMonI2CFailNotification NOTIFICATION-TYPE
        -- no OBJECTS
        STATUS  current
        DESCRIPTION
                "A notification of I2C state turns from normal(1) to
                     notFunctioning(7)"
        ::= { apEnvMonMIBNotifications 1 }


apEnvMonStatusChangeNotification NOTIFICATION-TYPE
        OBJECTS {
		apEnvMonTrapInstance,
                apEnvMonTrapPreviousState,
                apEnvMonTrapCurrentState
                }
        STATUS  current
        DESCRIPTION
                "A apEnvStatusChangeNotification is sent if any entry of
                above table change in the state of a device being monitored"
        ::= { apEnvMonMIBNotifications 2 }


apEnvMonTempChangeNotification NOTIFICATION-TYPE
        OBJECTS {
		apEnvMonTrapSlotID,
		apEnvMonTrapSlotType,
                apEnvMonTrapPreviousState,
                apEnvMonTrapCurrentState
                }
        STATUS  current
        DESCRIPTION
                "A notification is sent if any of the units cross a
		temperature threshold"
        ::= { apEnvMonMIBNotifications 3 }

apEnvMonVoltageChangeNotification NOTIFICATION-TYPE
        OBJECTS {
		apEnvMonTrapSlotID,
		apEnvMonTrapSlotType,
                apEnvMonTrapPreviousState,
                apEnvMonTrapCurrentState
                }
        STATUS  current
        DESCRIPTION
                "A notification is sent if any of the units cross a
		voltage threshold"
        ::= { apEnvMonMIBNotifications 4 }

apEnvMonPortChangeNotification		NOTIFICATION-TYPE
	OBJECTS		{ apEnvMonTrapPortType,
			  apEnvMonTrapPresence,
			  apEnvMonTrapSlotID,
			  apEnvMonTrapPortID
			}
	STATUS	   	current
	DESCRIPTION
	      " The trap will be generated if a physical port is
		inserted/present or removed/not present. "
	::= { apEnvMonMIBNotifications 5 }

-- conformance information

apEnvMonMIBConformance OBJECT IDENTIFIER ::= { apEnvMonModule 5 }
apEnvMonMIBCompliances OBJECT IDENTIFIER ::= { apEnvMonMIBConformance 1 }
apEnvMonMIBGroups      OBJECT IDENTIFIER ::= { apEnvMonMIBConformance 2 }


-- compliance statements

-- units of conformance
apEnvMonGroup OBJECT-GROUP
        OBJECTS {
                apEnvMonI2CState,

                apEnvMonVoltageStatusType,
                apEnvMonVoltageStatusDescr,
                apEnvMonVoltageStatusValue,
                apEnvMonVoltageState,

                apEnvMonTemperatureStatusType,
                apEnvMonTemperatureStatusDescr,
                apEnvMonTemperatureStatusValue,
                apEnvMonTemperatureState,

		apEnvMonFanStatusType,
                apEnvMonFanStatusDescr,
                apEnvMonFanStatusValue,
                apEnvMonFanState,

		apEnvMonPowerSupplyStatusType,
                apEnvMonPowerSupplyStatusDescr,
                apEnvMonPowerSupplyState,

		apEnvMonPhyCardStatusType,
                apEnvMonPhyCardStatusDescr,
                apEnvMonPhyCardState,

                apEnvMonEnableStatChangeNotif
        }
        STATUS  current
        DESCRIPTION
                "A collection of objects providing environmental
                 monitoring capability to an Acme Packet chassis."
        ::= { apEnvMonMIBGroups 1 }

apEnvMonNotifyGroup NOTIFICATION-GROUP
        NOTIFICATIONS {
                 apEnvMonStatusChangeNotification,
                 apEnvMonI2CFailNotification
        }
        STATUS   current
        DESCRIPTION
                 "A collection of notifications providing the status
                  change for environmental monitoring."
        ::= { apEnvMonMIBGroups 3 }

apEnvMonExtGroup OBJECT-GROUP
        OBJECTS {
	        apEnvMonVoltageSlotID,
                apEnvMonVoltageSlotType,

		apEnvMonTemperatureSlotID,
                apEnvMonTemperatureSlotType,

		apEnvMonFanSlotID		
		}
        STATUS  current
        DESCRIPTION
                "Additional objects providing environmental
                 monitoring capability to an Acme Packet chassis."
        ::= { apEnvMonMIBGroups 4 }
                                                          

apEnvMonCardGroup OBJECT-GROUP
        OBJECTS {
	         apEnvMonCardSlot,
		 apEnvMonCardType,
		 apEnvMonCardDescr,
		 apEnvMonCardHealthScore,
		 apEnvMonCardState,
		 apEnvMonCardRedundancy,

		 apEnvMonCpuCoreIndex,
		 apEnvMonCpuCoreDescr,
		 apEnvMonCpuCoreUsage,
		 apEnvMonCpuCoreState,
		 apEnvMonCpuCoreRamDescr,
		 apEnvMonCpuCoreRamUsage
		}
        STATUS  current
        DESCRIPTION
                "A collection of objects providing environmental
                 monitoring capability to card-based Acme Packet products."
        ::= { apEnvMonMIBGroups 5 }

apEnvMonExtNotifyGroup NOTIFICATION-GROUP
        NOTIFICATIONS {
		 apEnvMonTempChangeNotification,
		 apEnvMonVoltageChangeNotification
        }
        STATUS   current
        DESCRIPTION
                 "Additional collection of notifications providing the status
                  change for environmental monitoring."
        ::= { apEnvMonMIBGroups 6 }


apEnvMonPortNotifyGroup NOTIFICATION-GROUP
        NOTIFICATIONS {
		 apEnvMonPortChangeNotification
        }
        STATUS   current
        DESCRIPTION
                 "Notifications to indicate physical port changes."
        ::= { apEnvMonMIBGroups 7 }

apEnvMonTempNotifyGroup NOTIFICATION-GROUP
        NOTIFICATIONS {
		 apEnvMonTempChangeNotification
       }
        STATUS   current
        DESCRIPTION
                 "Additional collection of notifications providing the status
                  change for environmental monitoring."
        ::= { apEnvMonMIBGroups 8 }


END