C-PRODUCT-CBR-MIB DEFINITIONS ::= BEGIN

IMPORTS
   cbr			FROM C-PRODUCT-GROUP-MIB
   portSlot,
   portNumber,
   vcpSideId,
   TimeAndDate		FROM C-PRODUCT-BASE-MIB
   Counter		FROM RFC1155-SMI
   OBJECT-TYPE		FROM RFC-1212;

-- Data Types

-- CBR groups

cbrDS1E1CardConfig	OBJECT IDENTIFIER ::= {cbr 1}
cbrDS1E1PortConfig	OBJECT IDENTIFIER ::= {cbr 2}
cbrDS1E1VcConfig	OBJECT IDENTIFIER ::= {cbr 3}
cbrDS1E1ATMStats        OBJECT IDENTIFIER ::= {cbr 4}
cbrV35PortConfig        OBJECT IDENTIFIER ::= {cbr 5}
cbrDS1E1NewVcConfig	OBJECT IDENTIFIER ::= {cbr 6}
cbrDS1E1NewATMStats     OBJECT IDENTIFIER ::= {cbr 7}

-- CBR Card Configuration Group (cbrDS1E1CardConfig)

cbrDS1E1CardConfTable OBJECT-TYPE
    SYNTAX SEQUENCE OF CbrDS1E1CardEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "This object contains the CBR specific card Configuration table.
        There is one cbrDS1E1CardConfEntry associated for each provisioned
        CBR interface within the shelf.  This table uses portSlot as an index
        which is defined in the portBaseTable of the C-PRODUCT BASE MIB.
        This index value uniquely identifies the CBR interface to which this
        entry is applicable."
    ::= {cbrDS1E1CardConfig 1}

cbrDS1E1CardConfEntry OBJECT-TYPE
    SYNTAX CbrDS1E1CardEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
	    "An entry in the CBR specific card Configuration table."
    INDEX { portSlot }
    ::= {cbrDS1E1CardConfTable 1}

CbrDS1E1CardEntry ::=
    SEQUENCE {
	cbrDS1E1CardRefPort
	    INTEGER
    }

cbrDS1E1CardRefPort OBJECT-TYPE
    SYNTAX INTEGER (1..8)
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
	"This object indicates which port the receive clock may be selected as
	the system reference clock source.  The value range starts at 1 and the
	maximum value is dependent upon the total number of physical ports on
	the specified CBR interface.  Four and eight port CBR intefaces are
	supported.  An error is returned if this object is set outside the
	range of the specified physical card interface.  In addition, an error
	is returned if this slot has been selected as the system reference 
	clock and an attempt is made to change to a port not in-service.
	The default value is port 1 (1)."
    DEFVAL { 1 }
    ::= {cbrDS1E1CardConfEntry 1}

-- CBR Port Configuration Group (cbrDS1E1PortConfig)

cbrDS1E1PortConfTable OBJECT-TYPE
    SYNTAX SEQUENCE OF CbrDS1E1PortEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
	"This object contains the CBR specific port Configuration table.
	There is one cbrDS1E1PortConfEntry associated for each provisioned
	CBR port interface within the shelf.  This table uses portSlot and
	portNumber as an index which is defined in the portBaseTable of the
	C-PRODUCT BASE MIB. This index value uniquely identifies the CBR port
	interface to which this entry is applicable."
    ::= {cbrDS1E1PortConfig 1}

cbrDS1E1PortConfEntry OBJECT-TYPE
    SYNTAX CbrDS1E1PortEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
	    "An entry in the CBR specific port Configuration table."
    INDEX { portSlot, portNumber }
    ::= { cbrDS1E1PortConfTable 1 }

CbrDS1E1PortEntry ::=
    SEQUENCE {
	cbrDS1E1PortConfLBO
	    INTEGER,
	cbrDS1E1PortConfLineCode
	    INTEGER,
	cbrDS1E1PortConfPortMode
	    INTEGER, 
	cbrDS1E1PortConfFraming
	    INTEGER,
	cbrDS1E1PortConfTiming
	    INTEGER,
	cbrDS1E1PortConfSignaling
	    INTEGER,
	cbrDS1E1PortConfCRC-4
	    INTEGER,
	cbrDS1E1PortConfDS0Channels
	    INTEGER,
	cbrDS1E1PortConfLoopBackType
	    INTEGER
    }

cbrDS1E1PortConfLBO OBJECT-TYPE
    SYNTAX INTEGER {
	       dsx-0-110ft(1),
	       dsx-110-220ft(2),
	       dsx-220-330ft(3),
	       dsx-330-440ft(4),
	       dsx-440-550ft(5),
	       dsx-550-600ft(6),
	       dsx-GT-600ft(7)
	   }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
	"This object is applicable to a T1-DSX CBR interface ONLY and 
	indicates the associated Line Build Out configuration for the
	designated port.  An error is returned if an access is attempted on
	a physical interface other than a T1-DSX port interface.  The default
	value is 330 to 440 feet (4)."
    DEFVAL { dsx-330-440ft }
    ::= {cbrDS1E1PortConfEntry 1}

cbrDS1E1PortConfLineCode OBJECT-TYPE
    SYNTAX INTEGER {
	       ami(1),
	       t1-B8ZS(2),
	       e1-HDB3(3)
	   }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
	"This object indicates the zero code suppression technique
	configured to the specified T1/E1 port interface.  The bipolar
	with 8 zero substitution (B8ZS) technique is applicable to T1
	interfaces ONLY.  The High Density Binary Three (HDB3) is
	applicable to E1 interfaces ONLY." 
    ::= {cbrDS1E1PortConfEntry 2}

cbrDS1E1PortConfPortMode OBJECT-TYPE
    SYNTAX INTEGER {
	       unstructured(1),
	       struct-voice(2),
	       struct-data(3)
	   }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
	"This object indicates the type of service configured to the
	specified T1/E1 port interface.  Unstructured allows the 
	application to utilize the entire available bandwidth at a
	bit rate of 1.544 Mb/s for T1 or 2.048 Mb/s for E1.  T1/E1 Framing
	is optional in this service mode.  Structured service provides Nx64
	kbit/s capability where N ranges between 1 and the maximum number of
	available DS0 channels.  Struct-Voice passes traffic with signaling
	informaion enabled.  Struct-Data passes traffic with signaling
	information disabled.  Changing the mode configuration will cause
	the following parameters to be changed.               

        .                      framing  timing signaling crc-4
        .                      -------  ------ --------- -----
	.      T1 unstructured unframed N/A    N/A       N/A
        .         struct data  ESF      loop*  N/A       N/A
        .         struct voice ESF      loop*  N/A       N/A 
        .      E1 unstructured unframed N/A    disable   disable
        .         struct data  single   loop*  disable   disable
        .         struct voice multi    loop*  enable    enable

	* timing is converted to loop timing only if timing is previously
	. configured to be in SRTS or adaptive timing modes

	NOTE:  Changing this object to a different mode will cause all
	previously associated VCC's to be deleted.  The default value for
	this object is unstructured (1)."
    DEFVAL { unstructured }
    ::= { cbrDS1E1PortConfEntry 3 }

cbrDS1E1PortConfFraming OBJECT-TYPE
    SYNTAX INTEGER {
	       unframed(1),
	       t1-D4(2),
	       t1-ESF(3),
	       e1-single-frame(4),
	       e1-multi-frame(5)
	   }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
	"This object indicates the type of frame organization configured for
	the specified T1/E1 port interface.  D4 and ESF frame organizations
	apply to T1 interfaces ONLY. Single-frame and multi-frame organizations
	pertain to E1 interfaces ONLY.  An error is returned if a set is
	applied to an inappropriate cardtype (eg. T1-D4 is applied to an E1
	cardtype).  Unframed is not a valid configuration in a structured mode.
	The E1 interface will not allow framing to be changed in structured
	voice mode.  Changing the framing configuration for an E1 interface
	will cause the following parameters to be changed in unstructured
	and structured data modes.

        .                             signaling crc-4
        .                             --------- -----
        .             E1 unframed     disable   disable
        .                single-frame disable*  disable
        .                multi-frame  enable*   enable

	* signaling is automatically changed in unstructured mode only

	The default value is unframed (1)."
    DEFVAL { unframed }
    ::= { cbrDS1E1PortConfEntry 4 }

cbrDS1E1PortConfTiming OBJECT-TYPE
    SYNTAX INTEGER {
	       system(1),
	       loop(2),
	       srts(3),
	       adaptive(4)
	   }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
	"This object indicates the type of input clock service configured for
	the specified T1/E1 port interface. Synchronous Residual Time Stamp
	(SRTS) and Adaptive timing modes are ONLY available in unstructured
	mode.  System configures the port interface to use the system reference
	clock within the shelf as a reference for transmitting.  Loop uses
	the input port Rx clock as the timing source.  An error is returned if
	an access is attempted to set this object in an inappropriate port
	mode (eg. SRTS is applied in structured voice mode).  The default value
	is adaptive (4)."
    DEFVAL { adaptive }
    ::= { cbrDS1E1PortConfEntry 5 }

cbrDS1E1PortConfSignaling OBJECT-TYPE
    SYNTAX INTEGER {
	       no-signaling(1),
	       e1-CAS(2)
	   }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
	"This object is applicable to E1 interfaces ONLY and indicates if
	signaling information is enabled or disabled.  Signaling information
        is always disabled in E1 single-frame or unframed mode.  Signaling
	information is always enabled in structured voice multi-frame mode.
	An error is returned if a set is applied to an inappropriate cardtype
	(eg. E1-CAS is applied to a T1 cardtype).  In addition, the crc-4
	configuration object is automatically disabled if the E1 interface is
	in unstructured multi-frame mode and signaling is disabled. 
	
	NOTE:  This object can ONLY be changed in E1 unstructured multi-frame
	mode.  The default value is no-signaling (1)."
    DEFVAL { no-signaling }
    ::= { cbrDS1E1PortConfEntry 6 }

cbrDS1E1PortConfCRC-4 OBJECT-TYPE
    SYNTAX INTEGER {
	       disabled(1),
	       enabled(2)
	   }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
	"This object is applicable to E1 interfaces ONLY and indicates if
	CRC-4 information is enabled or disabled.  CRC-4 information is
        always disabled in E1 single-frame or unframed mode.  CRC-4 
        information is always enabled in multi-frame mode with signaling
        disabled.  NOTE: This object can ONLY be modified in E1 CAS multi-frame
        mode.  The default value is disabled (1)."
    DEFVAL { disabled }
    ::= { cbrDS1E1PortConfEntry 7 }

cbrDS1E1PortConfDS0Channels OBJECT-TYPE
    SYNTAX INTEGER 
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "This object indicates the associated DS0's which have been assigned
         to the specified physical port interface.  All available DS0 channels
         are automatically allocated in unstructured mode. In structured mode,
         the DS0 channels are bit-coded with each bit representing one DS0
         channel.  The following are some examples:
 
            Value                       Representation
         0x00000002     DS0-1 has been allocated to this port
         0x000007f0     DS0-4 to DS0-10 have been allocated to this port
         0x00027004     DS0-2, DS0-12 to DS0-14, DS0-17 have been allocated
	 
	 In E1 structured voice mode, the bit fields correspond to telephone 
	 channels and are automatically mapped to it's associated DS0
	 channel. Valid telephone channels range from 1 to 30.
	 "
    ::= { cbrDS1E1PortConfEntry 8 }

cbrDS1E1PortConfLoopBackType OBJECT-TYPE
    SYNTAX INTEGER {
	       no-loopback(1),
	       network-line(2),
	       local-card(3),
	       network-card(4),
	       no-response(5)
	   }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
	"This object indicates the type of loopback configured for the
	specified T1/E1 port interface. Network-line (2) redirects incoming
	remote traffic back into the network interface at the external edge of
	the card interface. Network-card (4) regenerates framing information
	prior to redirecting incoming remote traffic back into the network
	interface.  Local-card (3) redirects local incoming traffic back into
	the local system.  The default value is no-loopback (1)."
    DEFVAL { no-loopback }
    ::= { cbrDS1E1PortConfEntry 9 }

-- This definition is good only for Lodi 1.4 & 1.5, Use new implementation
-- If you had to modify anything for Baja & Lodi 2.0
-- CBR VC Configuration Group (cbrDS1E1VcConfig)

-- CBR ATM Statistics Group (cbrDS1E1ATMStats)

-- For Baja & Lodi 2.0 onwards
-- CBR New VC Configuration Group (cbrDS1E1NewVcConfig)

cbrDS1E1NewVcConfTable OBJECT-TYPE
    SYNTAX SEQUENCE OF CbrDS1E1NewVcEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
	"This object contains the CBR specific VC Configuration table.
	There is one cbrDS1E1VcConfEntry associated for each CBR VC connection
	provisioned within the shelf.  This table uses vcPortSlot, vcPortPort,
        vcPortTransmitVpi, vcPortTransmitVci, vcPortReceiveVpi, and 
	vcPortReceiveVci as an index which is defined in the vcBaseTable of
	the C-PRODUCT BASE MIB. This index value uniquely identifies the CBR
	VC connection to which this entry is applicable.

        NOTE:  The associated Circuit Emulation Service (CES) MIB defined by
        the ATM forum restricts the VC index to a single 32-bit scalar value.
        In support of this MIB, the CES MIB index retains the same indexing
        information as the enterprise MIB (with the exception of using 
	vcPortReceiveVpi and vcPortReceiveVci) but has been bit-mapped using
	the following construction:

           vcPortPort		bit  0..3
           vcPortSlot   	bit  4..8
           vcPortTransmitVci    bit  9..23
           vcPortTransmitVpi    bit 24..31"

    ::= { cbrDS1E1NewVcConfig 1 }

cbrDS1E1NewVcConfEntry OBJECT-TYPE
    SYNTAX CbrDS1E1NewVcEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
	    "An entry in the CBR specific VC Configuration table."
    INDEX { vcpSideId }
    ::= { cbrDS1E1NewVcConfTable 1 }

CbrDS1E1NewVcEntry ::=
    SEQUENCE {
	cbrDS1E1NewVcConfCDVT
	    INTEGER,
	cbrDS1E1NewVcConfIntegPeriod
	    INTEGER,
	cbrDS1E1NewVcConfPayloadSize
	    INTEGER,
	cbrDS1E1NewVcConfPayloadType
	    INTEGER, 
	cbrDS1E1NewVcConfOnHookDetection 
	    INTEGER,
	cbrDS1E1NewVcConfSignalingType 
	    INTEGER,
	cbrDS1E1NewVcConfDS0Channels
	    INTEGER 
    }

cbrDS1E1NewVcConfCDVT OBJECT-TYPE
    SYNTAX INTEGER (1..31) -- UNITS msecs
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
	"This object indicates the Cell Delay Variation Tolerance (CDVT)
         in msecs configured for the specified T1/E1 ATM VC connection.  The
	 CDVT value specifies the amount of cell delay uncertainty which may
	 be experienced by any particular cell.  The maximum CDVT value for a
	 T1 interface is 24.  The maximum CDVT value for an E1 interface is
	 31.  The default value is 1 msec (1)."
    DEFVAL { 1 }
    ::= { cbrDS1E1NewVcConfEntry 1 }

cbrDS1E1NewVcConfIntegPeriod OBJECT-TYPE
    SYNTAX INTEGER (2000..65535) -- UNITS msecs
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "This object indicates the Cell Loss Integration Period in msecs
         configured for the specified ATM VC connection.  If cell(s) are lost
         within this period, the ATM Cell Loss Status (ACLS) is set to loss.
         ACLS is accessible via the Circuit Emulation Service (CES) MIB defined
         by the ATM forum and/or the VT100 ATM statistics screen.  The default
         value is 2500 msecs (2500)."
    DEFVAL { 2500 }
    ::= { cbrDS1E1NewVcConfEntry 2 }

cbrDS1E1NewVcConfPayloadSize OBJECT-TYPE
    SYNTAX INTEGER (1..47) -- UNITS bytes
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
	"This object indicates the actual number of payload octets used per
         ATM cell size configured for the specified T1/E1 ATM VC connection.
         The default value is 47 bytes (47)."
    DEFVAL { 47 }
    ::= { cbrDS1E1NewVcConfEntry 3 }

cbrDS1E1NewVcConfPayloadType OBJECT-TYPE
    SYNTAX INTEGER {
	       none(1),
	       voice(2),
	       data(3)
	   }
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
	"This object indicates which payload type has been configured for the 
	 specified T1/E1 ATM VC connection.  It is reflective upon the T1/E1
	 port mode configuration (ie. none -> unstructured, voice -> structured
	 voice, data -> structured data).  The default is none (1)."
    DEFVAL { none }
    ::= { cbrDS1E1NewVcConfEntry 4 }

cbrDS1E1NewVcConfOnHookDetection OBJECT-TYPE
    SYNTAX INTEGER {
	       disabled(1),
	       enabled(2) 
	   }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
	"This object dynamically reallocates bandwidth based upon the detection
         of an on-hook condition as specified by the signaling type.  This 
         object is applicable in structured voice mode ONLY.  The default
         value is disabled (1)."
    DEFVAL { disabled }
    ::= {cbrDS1E1NewVcConfEntry 5}

cbrDS1E1NewVcConfSignalingType OBJECT-TYPE
    SYNTAX INTEGER {
               no-signaling(1),
	       em-plar(2),
	       fxo-loop-start(3),
	       fxs-loop-start(4),
	       fxo-ground-start(5),
	       fxs-ground-start(6),
               e1-r2(7)
	   }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
	"This object indicates the associated signaling application type. This
         object defaults to no_signaling in unstructured/structured data modes
         and cannot be modified in these modes. This object can only be set in 
         structured voice mode.  All signaling application type values are
         applicable in this mode except for no-signaling.  An error will result
         if an attempt is made to set no_signaling in structured voice mode.
	 In addition, an error will result if an attempt is made to set e1-r2
	 to a T1 interface.  The default value is no-signaling(1)."
    DEFVAL { no-signaling }
    ::= { cbrDS1E1NewVcConfEntry 6 }

cbrDS1E1NewVcConfDS0Channels OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
	"This object indicates the associated DS0's which have been assigned
         to the specified ATM VC connection.  All available DS0 channels are
         automatically allocated in unstructured mode. In structured mode, the
         DS0 channels are bit-coded with each bit representing one DS0 channel.
         The following are some examples:

            Value                       Representation
         0x00000002     DS0-1 has been allocated to this VC
         0x000007f0     DS0-4 to DS0-10 have been allocated to this VC
         0x00027004     DS0-2, DS0-12 to DS0-14, DS0-17 have been allocated

         DS0 channels can only be assigned in structured mode.  Channel
         conflicts within a T1/E1 port interface will result in an error.
		For CBR V35 Port the valid values are as follows:
	 Channel Selection 	Value		Data Rate
	 -----------------	------------    -----------
	 1			2		64k
	 1-2			6		128k	
	 1-3			14		192k		
	 1-4			30		256k		
	 1-6			126		384k		
	 1-8			510		512k		
	 1-12			8190		768k		
	 1-16			131070		1024k		
	 1-24			33554430	1536k			
	 "
    ::= { cbrDS1E1NewVcConfEntry 7 }

cbrDS1E1NewATMStatsTable OBJECT-TYPE
    SYNTAX SEQUENCE OF CbrDS1E1NewATMStatsEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "This object contains the CBR specific VC Statistics table.
        There is one cbrDS1E1ATMStatsEntry associated for each CBR VC connection
        provisioned within the shelf.  This table uses vcPortSlot, vcPortPort,
        vcPortTransmitVpi, and vcPortTransmitVci as an index which is defined
        in the vcBaseTable of the C-PRODUCT BASE MIB. This index value uniquely 
        identifies the CBR VC connection to which this entry is applicable.
        Additional VC statistics information is available in the associated
        Circuit Emulation Service (CES) MIB defined by the ATM forum.

        NOTE:  The associated Circuit Emulation Service (CES) MIB defined by
        the ATM forum restricts the VC index to a single 32-bit scalar value.
        In support of this MIB, the CES MIB index retains the same indexing
        information as the enterprise MIB but has been bit-mapped using the
        following construction:

           vcPortPort           bit  0..3
           vcPortSlot           bit  4..8
           vcPortTransmitVci    bit  9..23
           vcPortTransmitVpi    bit 24..31"

    ::= { cbrDS1E1NewATMStats 1 }

cbrDS1E1NewATMStatsEntry OBJECT-TYPE
    SYNTAX CbrDS1E1NewATMStatsEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
	    "An entry in the CBR specific VC Statistics table."
    INDEX { vcpSideId }
    ::= { cbrDS1E1NewATMStatsTable 1 }

CbrDS1E1NewATMStatsEntry ::=
    SEQUENCE {
	cbrDS1E1NewATMStatsRxCells
	    Counter,
	cbrDS1E1NewATMStatsTxCells
	    Counter,
	cbrDS1E1NewATMStatsOOSErrors
	    Counter,
	cbrDS1E1NewATMStatsCRCErrors
	    Counter,
	cbrDS1E1NewATMStatsOAMRxCells
	    Counter,
	cbrDS1E1NewATMStatsOAMTxCells
	    Counter,
	cbrDS1E1NewATMStatsClearStats
	    INTEGER,
	cbrDS1E1NewATMStatsResetTimeDate
	    TimeAndDate
    }

cbrDS1E1NewATMStatsRxCells OBJECT-TYPE
    SYNTAX Counter
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
	"This object indicates the total number of ATM cells received
	 over the T1/E1 ATM VC connection since the last ATM VC clear
	 time and date."
    ::= { cbrDS1E1NewATMStatsEntry 1 }

cbrDS1E1NewATMStatsTxCells OBJECT-TYPE
    SYNTAX Counter
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
	"This object indicates the total number of ATM cells transmitted
	 over the T1/E1 ATM VC connection since the last ATM VC clear
	 time and date."
    ::= { cbrDS1E1NewATMStatsEntry 2 }

cbrDS1E1NewATMStatsOOSErrors OBJECT-TYPE
    SYNTAX Counter
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
	"This object indicates the total number of out-of-sequence errors
	 detected over the specified T1/E1 ATM VC connection since the last
	 ATM VC clear time and date."
    ::= { cbrDS1E1NewATMStatsEntry 3 }

cbrDS1E1NewATMStatsCRCErrors OBJECT-TYPE
    SYNTAX Counter
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
	"This object indicates the total number of CRC errors detected over
	 the specified T1/E1 ATM VC connection since the last ATM VC clear
	 time and date."
    ::= { cbrDS1E1NewATMStatsEntry 4 }

cbrDS1E1NewATMStatsOAMRxCells OBJECT-TYPE
    SYNTAX Counter
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
	"This object indicates the total number of OAM cells received over
	 the specified T1/E1 ATM VC connection since the last ATM VC clear
	 time and date."
    ::= { cbrDS1E1NewATMStatsEntry 5 }

cbrDS1E1NewATMStatsOAMTxCells OBJECT-TYPE
    SYNTAX Counter
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
	"This object indicates the total number of OAM cells transmitted over
	 the specified T1/E1 ATM VC connection since the last ATM VC clear
	 time and date."
    ::= { cbrDS1E1NewATMStatsEntry 6 }

cbrDS1E1NewATMStatsClearStats OBJECT-TYPE
    SYNTAX INTEGER {
	       clear (1),
	       not-applicable (2)
	      }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
	"This object will (1) clear the ATM statistics counters and (2)
	initialize the reset time and date to the current time and date
	for the specified ATM VC connection.  NOTE:  A value of '2' is
	returned for any attempted reads of this object." 
    ::= { cbrDS1E1NewATMStatsEntry 7 }

cbrDS1E1NewATMStatsResetTimeDate OBJECT-TYPE
    SYNTAX TimeAndDate
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
	"This object indicates the last time and date the ATM statistics
	were cleared for the specified ATM VC connection."
    ::= { cbrDS1E1NewATMStatsEntry 8 }

END