-- Name:        3Com Port Security MIB
-- 
-- History  Date        Reason for Change
--
-- 1.00     1997        Issued as 3Com RFC.
-- 1.01     25 Jan 99   Added secureViolation4 TRAP
-- 1.02     29 Oct 99	Added disablePortTemporarily(4) to the
--                      secureIntrusionAction object.
--
-- **********************************************************************
-- Copyright 3Com Technologies Limited. (1996-1999)
-- **********************************************************************

A3COM0021-PORT-SECURITY DEFINITIONS ::= BEGIN


   IMPORTS
      securePort FROM A3COM0004-GENERIC
      OBJECT-TYPE FROM RFC-1212
      TRAP-TYPE FROM RFC-1215
      rptrPortAdminStatus FROM SNMP-REPEATER-MIB
      ;

securePortTable OBJECT-TYPE
   SYNTAX   SEQUENCE OF SecurePortEntry
   ACCESS   not-accessible
   STATUS   mandatory
   DESCRIPTION "This table defines the security status of each secure port. 
   Each port can have a number of authorised MAC addresses, and these are stored in 
   the secureAddressTable."
   ::= {securePort 1}

securePortEntry OBJECT-TYPE
   SYNTAX   SecurePortEntry
   ACCESS   not-accessible
   STATUS   mandatory
   DESCRIPTION "There is a row in this table for each secure port, and 
   allows repeater ports to be configured for security on a per port basis. It is 
   indexed using the objects secureSlotIndex and securePortIndex."
   INDEX {secureSlotIndex,securePortIndex}
   ::= {securePortTable 1}

SecurePortEntry ::= SEQUENCE {
      secureSlotIndex      INTEGER,
      securePortIndex      INTEGER,
      securePortMode    INTEGER,
      secureNeedToKnowMode    INTEGER,
      secureIntrusionAction      INTEGER,
      secureNumberAddresses      INTEGER,
      secureNumberAddressesStored      INTEGER,
      secureMaximumAddresses     INTEGER
      }

secureSlotIndex OBJECT-TYPE
   SYNTAX   INTEGER (1..1024)
   ACCESS   read-only
   STATUS   mandatory
   DESCRIPTION "The slot or unit number of the secure port. This is the 
   first index into the securePortTable."
   ::= {securePortEntry 1}

securePortIndex OBJECT-TYPE
   SYNTAX   INTEGER (1..1024)
   ACCESS   read-only
   STATUS   mandatory
   DESCRIPTION "The port number of the secure port. This is the second index 
   into the securePortTable."
   ::= {securePortEntry 2}

securePortMode OBJECT-TYPE
   SYNTAX   INTEGER  {
      noRestrictions (1),
      continuousLearning (2),
      autoLearn (3),
      secure (4)
   }
   ACCESS   read-write
   STATUS   mandatory
   DESCRIPTION "Determines the learning and security modes of the port. See 
   secureNeedToKnowMode and secureIntrusionAction to configure Need To Know and 
   Intrusion Action on each port.
   
   (When in a learning mode, secureNumberAddresses determines the maximum number of 
   addresses that can be learned on the port. This is set by the user.)
   
   noRestrictions(1)    All learning and security are disabled.
   
   continuousLearning(2)   Addresses are learned continually. If more
            addresses are learned than are permitted on the
            port, then one of the older entries will be aged
            out. Need To Know and Intrusion Action depends on
            secureNeedToKnowMode and secureIntrusionAction
            respectively.
   
   autoLearn(3)      All addresses for this port are deleted, and then
            addresses are learned up to the number permitted.
            securePortMode is then set to secure. Need To
            Know and Intrusion Action depends on
            secureNeedToKnowMode and secureIntrusionAction
            respectively.
   
   secure(4)      Learning is disabled. Need To Know and Intrusion
            Action depends on secureNeedToKnowMode and
            secureIntrusionAction respectively.
   
   The secureAddressLearned trap is sent whenever a station has been learned. The 
   secureViolation trap is sent whenever a packet is received from an unauthorised station."
   ::= {securePortEntry 3}

secureNeedToKnowMode OBJECT-TYPE
   SYNTAX   INTEGER  {
      notAvailable (1),
      disabled (2),
      needToKnowOnly (3),
      needToKnowWithBroadcastsAllowed (4),
      needToKnowWithMulticastsAllowed (5),
      permanentNeedToKnowOnly (6),
      permanentNeedToKnowWithBroadcastsAllowed (7),
      permanentNeedToKnowWithMulticastsAllowed (8)
   }
   ACCESS   read-write
   STATUS   mandatory
   DESCRIPTION "Attribute to determine which frames are to be forwarded to 
   this port intact.
   
   1 - Need To Know is not available. 2 - All frames. 3 - Frames addressed to the 
   authorised devices only. 4 - Frames addressed to the authorised devices,
            plus all broadcast frames.
   5 - Frames addressed to the authorised devices,
            plus all broadcast and multicast frames.
   6 - As 3 and cannot be changed. 7 - As 4 and cannot be changed. 8 - As 5 and 
   cannot be changed.
   
   If this object returns 1,6,7 or 8, it means that the Need To Know configuration 
   cannot be changed, and any attempt to write to this object will cause an error."
   ::= {securePortEntry 4}

secureIntrusionAction OBJECT-TYPE
   SYNTAX   INTEGER  {
      notAvailable (1),
      noAction (2),
      disablePort (3),
      disablePortTemporarily (4)
   }
   ACCESS   read-write
   STATUS   mandatory
   DESCRIPTION "Attribute to determine the action if an unauthorised device 
   tranmsits on this port."
   ::= {securePortEntry 5}

--
-- The following 3 objects are used to allow multiple MAC addresses to be 
-- assigned to the port.
secureNumberAddresses OBJECT-TYPE
   SYNTAX   INTEGER 
   ACCESS   read-write
   STATUS   mandatory
   DESCRIPTION "The maximum number of addresses that the port can learn or 
   store. Reducing this number may cause some addresses to be deleted. This value 
   is set by the user and cannot be automatically changed by the agent.
   
   The following relationship must be preserved.
      secureNumberAddressesStored <= secureNumberAddresses <=
   secureMaximumAddresses
   "
   ::= {securePortEntry 6}

secureNumberAddressesStored OBJECT-TYPE
   SYNTAX   INTEGER 
   ACCESS   read-only
   STATUS   mandatory
   DESCRIPTION "The number of addresses that are currently in the 
   AddressTable for this port. If this object has the same value as 
   secureNumberAddresses, then no more addresses can be authorised on this port.
   
   The following relationship must allows be preserved.
      secureNumberAddressesStored <= secureNumberAddresses <=
   secureMaximumAddresses
   "
   ::= {securePortEntry 7}

secureMaximumAddresses OBJECT-TYPE
   SYNTAX   INTEGER 
   ACCESS   read-only
   STATUS   mandatory
   DESCRIPTION "This indicates the maximum value that secureNumberAddresses 
   can be set to. It is dependent on the resources available so may change, eg. if 
   resources are shared between ports, then this value can both increase and 
   decrease. This object must be read before setting secureNumberAddresses.
   
   The following relationship must allows be preserved. secureNumberAddressesStored 
   <= secureNumberAddresses <= secureMaximumAddresses
   "
   ::= {securePortEntry 8}

--
-- SECURE ADDRESS TABLE
--
secureAddressTable OBJECT-TYPE
   SYNTAX   SEQUENCE OF SecureAddressEntry
   ACCESS   not-accessible
   STATUS   mandatory
   DESCRIPTION "This table which stores the MAC addresses assigned to each 
   port. Addresses will normally defined as authorised, and describe the devices 
   which are permitted to transmit and receive on the corresponding port.  This 
   table can be written to by the agent as well as the management station."
   ::= {securePort 2}

secureAddressEntry OBJECT-TYPE
   SYNTAX   SecureAddressEntry
   ACCESS   not-accessible
   STATUS   mandatory
   DESCRIPTION "This table allows multiple addresses to be assigned to each 
   secure port.  It is indexed using the objects secureAddrSlotIndex, 
   secureAddrPortIndex and secureAddrMAC."
   INDEX {secureAddrSlotIndex,secureAddrPortIndex,secureAddrMAC}
   ::= {secureAddressTable 1}

SecureAddressEntry ::= SEQUENCE {
      secureAddrSlotIndex     INTEGER,
      secureAddrPortIndex     INTEGER,
      secureAddrMAC     OCTET STRING,
      secureAddrRowStatus     INTEGER
      }

secureAddrSlotIndex OBJECT-TYPE
   SYNTAX   INTEGER (1..1024)
   ACCESS   read-only
   STATUS   mandatory
   DESCRIPTION "The slot or unit number of the secure port.  This is the 
   first index into the secureAddressTable."
   ::= {secureAddressEntry 1}

secureAddrPortIndex OBJECT-TYPE
   SYNTAX   INTEGER (1..1024)
   ACCESS   read-only
   STATUS   mandatory
   DESCRIPTION "The port number of the secure port.  This is the second 
   index into the secureAddressTable."
   ::= {secureAddressEntry 2}

secureAddrMAC OBJECT-TYPE
   SYNTAX   OCTET STRING  (SIZE(6))
   ACCESS   read-only
   STATUS   mandatory
   DESCRIPTION "The MAC address of a station assigned to this port.  This is 
   the third index into the secureAddressTable."
   ::= {secureAddressEntry 3}

secureAddrRowStatus OBJECT-TYPE
   SYNTAX   INTEGER  {
      active (1),
      notInService (2),
      notReady (3),
      createAndGo (4),
      createAndWait (5),
      destroy (6)
   }
   ACCESS   read-write
   STATUS   mandatory
   DESCRIPTION "This manages the creation and deletion or rows, and shows 
   the current status of the indexed MAC address.  This object has the following 
   values.
   
   1 - The indexed MAC address is authorised on this port. 2 - The indexed MAC 
   address is not authorised on this port. 3 - Not applicable. (This value 
   indicates an incomplete row.) 4 - Assign a new MAC address to the port and 
   authorise immediately. 5 - Assign a new MAC address to the port, but do not 
   authorise until active(1) is written to this object. 6 - Delete this entry.
   
   When creating a new entry, index a new row and use createAndGo(4) or 
   createAndWait(5). Some hardware will not allow the address to be unauthorised, 
   and will automatically switch the row to active(1). When reading this object, 
   only active(1) and notInService(2) will be returned.
   
   Only the values active(1) and destroy(6) will be allowed for an existing row, or 
   createAndGo(4) and createAndWait(5) for a new row."
   ::= {secureAddressEntry 4}

---
--- SECURITY TABLE 'STOP' OBJECT
---
secureStop OBJECT-TYPE
   SYNTAX   INTEGER 
   ACCESS   read-only
   STATUS   mandatory
   DESCRIPTION "A MIB object to speed up access to the security tables. When 
   performing a get-next through the table, this object is accessed as soon as the 
   table is passed and allows the management to quickly determine the end of the table."
   ::= {securePort 3}

END